Sie sind auf Seite 1von 2

Product data sheet

Characteristics

EZC250H3250

circuit breaker Easypact EZC250H - TMD - 250 A - 3 poles 3d

Main
Device short name Circuit breaker name Circuit breaker application Poles description Protected poles description Network type Network frequency [In] rated current [Ui] rated insulation voltage [Uimp] rated impulse withstand voltage [Ue] rated operational voltage Circuit breaker rating code Breaking capacity Easypact EZC250H Easypact EZC250H Distribution 3P 3t AC DC 50/60 Hz 250 A 40 C
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

690 V IEC 60947-2 AC 50/60 Hz 6 kV IEC 60947-2 250 V IEC 60947-2 DC 550 V IEC 60947-2 AC 50/60 Hz H 10 kA Icu IEC 60947-2 550 V AC 50/60 Hz 25 kA Icu IEC 60947-2 440 V AC 50/60 Hz 30 kA Icu IEC 60947-2 125 V DC 1P 30 kA Icu IEC 60947-2 250 V DC 2P 36 kA Icu IEC 60947-2 400...415 V AC 50/60 Hz 36 kA Icu IEC 60947-2 380 V AC 50/60 Hz 85 kA Icu IEC 60947-2 110...130 V AC 50/60 Hz 85 kA Icu IEC 60947-2 220...240 V AC 50/60 Hz 85 kA NEMA AB1 240 V AC 50/60 Hz 5 kA IEC 60947-2 550 V AC 50/60 Hz 15 kA IEC 60947-2 125 V DC 15 kA IEC 60947-2 250 V DC 18 kA IEC 60947-2 380 V AC 50/60 Hz 18 kA IEC 60947-2 400/415 V AC 50/60 Hz 12,5 kA IEC 60947-2 440 V AC 50/60 Hz 42,5 kA IEC 60947-2 110/130 V AC 50/60 Hz 42,5 kA IEC 60947-2 220/230/240 V AC 50/60 Hz Yes IEC 60947-2 Category A Thermal-magnetic 250 A 50 C Overload protection Short-circuit protection 3 IEC 947-1 3 IEC 60664-1

[Ics] rated service breaking capacity

Suitability for isolation Utilisation category Trip unit technology Trip unit rating Protection type Pollution degree

Complementary
Control type Mounting mode Mounting support Upside connection Downside connection Mechanical durability Electrical durability Connection pitch Toggle Fixed Backplate Front Front 10000 cycles 5000 cycles IEC 60947-2 415 V AC 50/60 Hz category A 35 mm

Nov 15, 2012

Local signalling Neutral protection setting Earth-leakage protection Height Width Depth

Positive contact indication Without protection Without 165 mm 105 mm 60 mm

Environment
Standards CSA 22-2 GB 14048.2 IEC 60947-2 JIS C8201-2-2 NEMA AB1 UL 508 IP20 IEC 60529 IK07 IEC 62262 -25...70 C -35...85 C 0801 Compliant

IP degree of protection IK degree of protection Ambient air temperature for operation Ambient air temperature for storage RoHS EUR conformity date RoHS EUR status

Das könnte Ihnen auch gefallen