Abstract
The effect of different heater surface configurations on two-phase flow instabilities has been investigated in a single channel, forced convection, open loop, up-flow system. Freon-11 is used as the test fluid, and six different heater tubes with various inside surface configurations have been tested at five different heat inputs. In addition to temperature and pressure recordings, high speed motion pictures of the two-phase flow were taken for some of the experiments to study the two-phase flow behavior at different operating points. Experimental results are shown on system pressure drop versus mass flow rate curves, and stability boundaries are also indicated on these curves. Comparison of different heater tubes is made by the use of the stability boundary maps and the plots of inlet throttling necessary to stabilize the system versus mass flow rate. Tubes with internal springs were found to be more stable than the other tubes.

Zusammenfassung
Der Einflu verschiedener Heizflchen-Konfigurationen auf Instabilitten bei Zweiphasenstrmungen wurde in einem einzelnen Kanal bei erzwungener Konvektion, offenem Kreislauf und Aufwrtsstrmung untersucht. Sechs unterschiedliche Heizrohre mit verschiedener Gestaltung der Innenflchen werden mit dem Fluid Freon-11 bei fnf verschiedenen Heizraten getestet. Um das Verhalten der Zweiphasenstrmung bei verschiedenen Betriebspunkten zu untersuchen, wurden bei einigen der Experimente neben Temperatur- und Druckmessungen auch Hochgeschwindigkeitsfilme von der Zweiphasenstrmung aufgenommen. Die experimentellen Ergebnisse werden durch Kurven des Systemdruckverlustes ber dem Massenstrom dargestellt, bei denen auch die Stabilittsgrenzen angezeigt sind. Verschiedene Heizrohre werden anhand von Stabilittskarten und der Diagramme zur Stabilisierung notwendige Einladrosselungen ber dem Massenstrom verglichen. Es wurde herausgefunden, da Rohre mit spiralfrmigen Einstzen stabiler sind als die anderen.

rd.springer.com/article/10.1007%2FBF02570526

1/6

1/6/14

Effect of heat transfer augmentation on two-phase flow instabilities in a vertical boiling channel - Springer

rd.springer.com/article/10.1007%2FBF02570526

2/6

1/6/14

Effect of heat transfer augmentation on two-phase flow instabilities in a vertical boiling channel - Springer

Related Content

References (8)

1. Veziroglu, T. N.; Kaka, S.: Two-phase flow instabilities and effect of inlet subcooling. University of Miami, Florida, Clean Energy Research Institute, final report, NSF project ENG 7516618 (1980) 2. Veziroglu, T. N.; Kaka, S.: Two-phase flow instabilities. University of Miami, Florida, Clean Energy Research Institute, annual report, NSF project CME 79-20018 (1981) 3. Akyzl, K.; Veziroglu, T. N.; Kaka, S.; Dogan, T.: Finite difference analysis of two-phase flow pressure-drop and density-wave oscillations. Wrme- Stoffbertrag. 14 (1980) 253267 CrossRef 4. Dogan, T.; Kaka, S.; Veziroglu, T. N.: Lumped parameter analysis of two-phases flow instabilities. 7th International Heat Transfer Conference, Mnchen 1982 5. Cumo, M.; Palazzi, G.; Rinaldi, L.: An experimental study on two-phase flow instability in parallel channels with different heat flux profile. Comitato Nazionale Energia Nucleare, report. ref. CNEN-RT/ING (81) 1 (1981) 6. Aritomi, M.; Aoki, A.; Inoue, A.: Instabilities in parallel channel of forced-convection boiling upflow system, (III)-system with different flow conditions between channels. J. Nucl. Sci. Technol. 16 (1979) 343355 CrossRef 7. Bergles, A. E.: Principles of heat transfer augmentation II, two-phase heat transfer. In: Kaka, S.; Bergles, A. E.; Mayinger, F. (Eds.): Heat Exchangers-Thermal Hydraulics Fundamentals and Design. New York: McGraw-Hill 1981 8. Lin, Z. H.; Veziroglu, T. N.; Kaka, S.; Grgenci, H.; Mente, A.: Heat transfer in oscillating two-phase flows and effect of heater surface conditions. 7th International Heat Transfer Conference, Mnchen 1982

About this Article


Title Effect of heat transfer augmentation on two-phase flow instabilities in a vertical boiling channel Journal Wrme - und Stoffbertragung
rd.springer.com/article/10.1007%2FBF02570526 3/6

1/6/14

Effect of heat transfer augmentation on two-phase flow instabilities in a vertical boiling channel - Springer

Volume 17, Issue 3 , pp 161-169 Cover Date 1983-05-01 DOI 10.1007/BF02570526 Print ISSN 0042-9929 Online ISSN 1432-1181 Publisher Springer-Verlag Additional Links Register for Journal Updates Editorial Board About This Journal Manuscript Submission Topics Industrial Chemistry/Chemical Engineering Thermodynamics Physics and Applied Physics in Engineering Theoretical and Applied Mechanics Engineering Fluid Dynamics Engineering Thermodynamics, Transport Phenomena Industry Sectors IT & Software Electronics Oil, Gas & Geosciences Engineering Aerospace Telecommunications
rd.springer.com/article/10.1007%2FBF02570526 4/6

1/6/14

Effect of heat transfer augmentation on two-phase flow instabilities in a vertical boiling channel - Springer

Chemical Manufacturing Automotive Consumer Packaged Goods Authors Dipl.-Ing. A. Mentes (1) Dipl.-Ing. O. T. Yildirim (2) Dr.-Ing. H. Grgenci (1) Prof. Dr. S. Kaka (2) Prof. Dr. T. N. Veziroglu (2) Author Affiliations 1. Department of Mechanical Engineering, Middle East Technical University, Ankara, Turkey 2. Department of Mechanical Engineering, University of Miami, 33124, Coral Gables, Florida, USA

Continue reading...
To view the rest of this content please follow the download PDF link above.
Over 8.3 million scientific documents at your fingertips Springer, Part of Springer Science+Business M edia