Guang Song

Dyna6 for inlet compressor foundation

steelcalgary@gmail.com http://steelcalgary.blogspot.ca/

Step by step guide for dyna6 input of inlet compressor foundation design

Setting Units To set the units of the problem:

Select the SETTINGS menu.

When the SETTINGS window appears, choose SI units and choose RPM for the frequency, set damping safety factor 2, and press O.K button.

Dyna6 for inlet compressor foundation

Defining the Foundation Type To select the foundation type:

Select the EDIT FOUNDATION menu.

When the FOUNDATION window appears, choose PILE and select the Embeded, Rectangle and Rigid options. Press the O.K button to proceed to next step.

Dyna6 for inlet compressor foundation

After pressing the OK button the Pile Foundation window appears.

Dyna6 for inlet compressor foundation To enter Pile Cap Details:


Press the PILE CAP button. After pressing the button the Footing Base Dimensions and Data Window appears.

Enter the needed pile cap data if you know them. If not press calculate and enter the data of each element in the pile cap and the program will calculate the needed data.

Dyna6 for inlet compressor foundation

Press the O.K button to proceed. Now, the Pile Foundation window will appear again. Press the PILES button to enter the coordinates of the piles as shown below Enter the pile properties and the pile material properties data as shown below Select the Fixed Head and the End-Bearing Tip options.

Dyna6 for inlet compressor foundation

Dyna6 for inlet compressor foundation

Press the O.K button to proceed. After pressing the O.K button the Pile Foundation window will appear again. Press the PILE-SOIL button to enter the data of the soil layer as shown below. Select the Layered and the Interaction options. Within the Pile Element tab enter the Pile details. Within the Soil Element tab enter the soil details

Dyna6 for inlet compressor foundation

Press the O.K button to continue. The Pile Foundation window will appear again. Press the SOIL BELOW button to enter the properties of the soil below the tip of the piles as show below.

Dyna6 for inlet compressor foundation When the Harmonic Load Data window appears, choose the Output Phase Angle checkbox and enter harmonic load details as shown in the above Figure. To enter the vertical out of phase force:

Select the out of phase option. Press on the Phase Shift button.

When the Phase Shift Angles for the Harmonic Loads window appears, enter 90 in the phase shift for force in Z-Dir. Box, 90 in the phase shift for the moment about X-Dir. Box and Press the O.K button.

Defining the Load To select the load type:

Select the LOAD menu.

When the LOAD window appears, choose HARMONIC and Press the O.K button to proceed to next step.

Dyna6 for inlet compressor foundation

Das könnte Ihnen auch gefallen