INTRACOM S.A. TELECOM SOLUTIONS, 2009. All rights reserved. All copyright, intellectual and industrial rights in this document and in the technical knowledge it contains are owned by INTRACOM S.A. TELECOM SOLUTIONS and/or their respective owners. This document is made available to the end users only for their internal use. No part of this document nor any data herein may be published, disclosed, copied, reproduced, redistributed by any form or means, electronically or mechanically, or used for any other purpose whatsoever without the prior written approval of INTRACOM S.A. TELECOM SOLUTIONS. Information as well as drawings and specifications contained in this document are subject to change without prior notice. All trademarks and copyrights mentioned herein are the property of INTRACOM S.A. TELECOM SOLUTIONS and/or their respective owners. Any rights not expressly granted herein are reserved. Printed in Greece.
INTRACOM TELECOM 19.7 km Markopoulou Ave., Peania, Athens, GR 19002 T +30 210 667 1000, F +30 210 667 1001 http://www.intracom-telecom.com
ibas_rel6_Technical_Description_Edition3.doc
Table of Contents
1. 2. System Overview .............................................................................................................. 1 Applications ...................................................................................................................... 4 Triple Play Provisioning for Residential Customers .................................................... 5 Double Play Provisioning for Business Customers..................................................... 7 3. System Composition ........................................................................................................ 8 Chassis...................................................................................................................... 8 Units ........................................................................................................................ 10 4. Service Delivery Mechanisms ........................................................................................ 13 5. Rack Solutions ................................................................................................................ 14 504 ADSL over PSTN Combo Ports......................................................................... 15 1008 ADSL over PSTN Combo Ports....................................................................... 19 2016 ADSL over PSTN Combo Ports....................................................................... 24 3024 ADSL over PSTN Combo Ports....................................................................... 27 6. Cabinet Solutions............................................................................................................ 29 360 ADSL over PSTN Combo Ports & 360 PSTN Ports........................................... 30 504 ADSL over PSTN Combo Ports......................................................................... 33 7. Management .................................................................................................................... 35 8. System Features ............................................................................................................. 37 ADSL-72/2+A Blade................................................................................................. 37 xPU Blade................................................................................................................ 38 POTS-72 Blade........................................................................................................ 40 NPU Blade ............................................................................................................... 41 9. Technical Specifications ................................................................................................ 42 Electrical Specifications ........................................................................................... 42 Mechanical Specifications........................................................................................ 43 Environmental Specifications ................................................................................... 43 WAN Interfaces........................................................................................................ 44 Subscriber Ports Capacity........................................................................................ 44 Splitters.................................................................................................................... 44 Management Interfaces ........................................................................................... 46 Compliance & Certifications ..................................................................................... 47 10. Abbreviations .................................................................................................................. 48
ibas_rel6_Technical_Description_Edition3.doc
ii
ibas_rel6_Technical_Description_Edition3.doc
1. System Overview
Introduction
iBAS MSAN is a high density Multi Service Access Node, part of INTRACOM TELECOMs wireline access portfolio. The iBAS MSAN is specially designed for the provision of: Broadband Services (High Speed Internet, Video broadcasting, Video on Demand, On-line gaming, VoIP transparent) Narrowband Services (Lifeline Voice Services) These services are provided concurrently from the same chassis, taking full advantage of the Ethernet transmission backbone. The system is fully compatible with all current requirements of leading telecommunications operators active in the field of Triple-Play services (Voice, Data and Video). Environmentally hardened, the system is suitable for both indoor and outdoor installations, in Central Offices and Remote Cabinets deployments. The system can be both centrally managed via integrated service oriented Network Management Systems and locally managed via windows-based graphical SNMP application and CLI.
Market focus
Designed in compliance with DSL Forums TR-101, iBAS MSAN addresses the strict but vital requirements of the target applications for: High bandwidth, both on the uplink and the subscriber side Video multicasting Quality of Service Security guarantee The system supports multiple Gigabit Ethernet interfaces, optical or electrical, to the aggregation network while on the subscriber side, it supports ADSL2+ providing high bandwidth connectivity and lifeline POTS interfaces.
Continued on next page
ibas_rel6_Technical_Description_Edition3.doc
Three 19 subrack options are available: High Capacity IBAS Subrack (HCIS/M-X) with 1152 ADSL2+ or 1008 POTS ports capacity Medium Capacity IBAS Subrack (MCIS) with 360 ADSL2+ or 288 POTS ports capacity High Capacity IBAS Subrack (HCIS/M) with patch-panel with 1152 ADSL2+ or 1008 POTS ports capacity (the subrack is used in case V5.2 connectivity is required)
HCIS/M Subrack
Continued on next page
ibas_rel6_Technical_Description_Edition3.doc
Specially designed platform for mass delivery of triple-play services to residential customers - 56 Gbit/s non-blocking switching capacity for simultaneous High speed Internet and real-time streaming (e.g. VoD) - Optimized for multicast video. Multicasting is performed at two stages: at the Central Control Unit toward the Line Cards and at the Line Cards toward the individual lines. - Eight WAN (network-facing) interfaces Highest port density (1152 ADSL2/2+ ports or 1008 POTS ports) from the smallest footprint (12 U) Two capacity / chassis options (1152 / 360 ADSL2/2+ ports or 1008 / 288 POTS ports) Common solution for indoor (CO) and outdoor deployment due to wide operating temperature range (-40 C to +55 C) Optimized video quality delivery due to enhanced INP4 noise protection (exceeds G.992.3 May 2005 Amendment) Field proven flexible integration to any Operators network due to inherent modular software architecture Full support of the NGN architecture, compatible with multiple vendors softswitches Protected, future-proof backplane architecture with full power redundancy features and protected point-to-point internal connections for all fitted blades Local and remote GUI (SNMP) or CLI management capabilities through in-band or out-band paths Integrated, service oriented Network Management System for ADSL2/2+ and POTS ports
Key benefits
Fast increase of revenue delivers Next Generation services from the existing copper infrastructure High density & cost-effective platform requiring low initial CapEx Future-proof system architecture with multiservice support for low risk of investment and fast ROI Universal solution (for CO and remote cabinet deployments) for minimized OpEx, maintenance & inventory costs Field-proven, highly reliable platform less downtime, increased customer satisfaction & minimized customer churn Operational efficient, end-to-end management with service level visibility
ibas_rel6_Technical_Description_Edition3.doc
2. Applications
The iBAS MSAN can offer both broadband and narrowband services to residential and business customers. For this purpose, it supports different network topologies and service delivery architectures in compliance with the most stringent international standards. In the following paragraphs, you will find certain applications examples implementing typical scenarios with indicative service delivery architectures. In these applications examples, the end user traffic carried in the access loop is forwarded to the aggregation network from the iBAS MSAN using Ethernet framing. In the aggregation network, the traffic could be grouped into VLANs (N:1 or 1:1 VLAN architectures) depending on the application and service providers requirements.
ibas_rel6_Technical_Description_Edition3.doc
In this architecture, each service delivered over the ADSL interface could be transferred in a separate VC while lifeline voice services could be delivered from POTS interfaces. The traffic from many different customers related to the same service, could be consolidated into one VLAN in the aggregation network (N:1 VLAN). This architecture is usually used for residential services. The Ethernet frames are usually transmitted from the CPE as VLAN untagged.
The mixed configuration of the iBAS MSAN with broadband and narrowband Line Termination Units makes possible the connection of a lifeline analogue phone and an analogue phone for voice over broadband (VoIP) at the customer premises.
Continued on next page
ibas_rel6_Technical_Description_Edition3.doc
In this architecture, all services per customer delivered over the ADSL interface could be transferred in the same VC with different VLAN tags while lifeline voice services could be delivered from POTS interfaces. The traffic from many different customers related to the same service, could be consolidated into one VLAN in the aggregation network (N:1 VLAN). This architecture is usually used for residential services. The customers CPE should support VLAN tagging (according to IEEE 802.1q).
The mixed configuration of the iBAS MSAN with broadband and narrowband Line Termination Units makes possible the connection of a lifeline analogue phone and an analogue phone for voice over broadband (VoIP) at the customer premises.
ibas_rel6_Technical_Description_Edition3.doc
In this architecture, all services per customer delivered over the ADSL interface could be transferred in the same VC or in multiple VCs, as previously described. The traffic from each customer related to the same service could be consolidated into one VLAN in the aggregation network (1:1 VLAN). In case the same VLAN is used for both services, the service differentiation could be implemented through different Ethernet priority markings (IEEE 802.1p).
Service Provider Network Access Network Customer #1
Data VLAN 1
Aggregation Network
Data VLAN 2
Splitter
Voice VLAN 2
Voice (analogue)
Lifeline Phone
Customer #2
ADSL o POTS
Splitter
Voice (analogue)
Lifeline Phone
The mixed configuration of the iBAS MSAN with broadband and narrowband Line Termination Units makes possible the connection of a lifeline analogue phone and an analogue phone for voice over broadband (VoIP) at the customer premises.
ibas_rel6_Technical_Description_Edition3.doc
3. System Composition
iBAS MSAN is composed of a chassis housing the Central Control Unit(s) and different types of Line Termination Units(s) (LTUs). The Power Supply Unit(s) and the Fan Tray complete the composition of the system.
Chassis
You can select among the following chassis options: HCIS/M-X MCIS HCIS/M Additionally, two types of splitters chassis are available for separation of the ADSL and PSTN signals from the ADSL-over-POTS channels.
HCIS/M-X
Photo
Model Description
High Capacity iBAS Subrack (HCIS/M-X) Chassis Chassis 19, fits in 12 U rack space, accommodates eighteen iBAS blades and two PSFFC-X units; it features a separate compartment on top for installing a fan tray.
MCIS
ibas_rel6_Technical_Description_Edition3.doc
Chassis,
HCIS/M
Continued
Photo
Model
High Capacity iBAS Subrack (HCIS/M) Chassis Chassis 19, 14 U high, for accommodating eighteen iBAS blades and two PSFFC-X units; it features a separate compartment on top for installing a fan tray, and also a patch panel at the bottom, with secure door.
NOTE
Description
Photo
Model Description
14 slots 19 Splitter Subrack Chassis Chassis 19, 6 U high, for accommodating fourteen splitter blades that separate the ADSL and PSTN signals from 72 ADSL-overPOTS channels.
Photo
Model Description
8 slots 19 Splitter Subrack Chassis Chassis 19, 6 U high, for accommodating seven splitter blades that separate the ADSL and PSTN signals from 72 ADSL-over-POTS channels.
ibas_rel6_Technical_Description_Edition3.doc
Units
Central Control Units
Photo
Model
xPU-8SG
xPU-4/4G
NPU-IPS VoIP version of Narrowband Processing Unit with 2 x 10/100Base-T electrical (RJ-45) uplink interfaces
NPU-16E1/IPS V5 / VoIP version of Narrowband Processing Unit supporting 16 x E1 (120 ) interfaces complied to V5.2 protocol and 2 x 10/100Base-T electrical (RJ-45) uplink interfaces
Description
Broadband Processing Unit with 4 x GbE (SFP) and 4 x GbE electrical (RJ-45) uplink interfaces
10
ibas_rel6_Technical_Description_Edition3.doc
Units,
LTUs
Continued
Photo
PSUs
Photo
PSFFC-X Power Supply Filter & Fan Control unit, with high current capability
11
ibas_rel6_Technical_Description_Edition3.doc
Units,
Fan Trays
Continued
Photo
FANT-X Slide-in Fan Tray module featuring three DC-powered fans (1)
Splitter Units
Photo
Model
SP-72P14 Splitter unit for separation of the ADSL and PSTN signals from 72 ADSL-overPOTS channels (affords two groups of three receptacles each, at the front panel, for connection to the ADSL-72/2+A and POTS-72 blades and one group of three receptacles, back accessible, for termination of 72 line ADSL-over-POTS signals)
SP-72P8 Splitter unit for separation of the ADSL and PSTN signals from 72 ADSL-overPOTS channels (affords two groups of three receptacles each, at the front panel, for connection to the ADSL-72/2+A and POTS-72 blades and one group of three receptacles, also at the front panel, for termination of 72 line ADSL-over-POTS signals)
Description
12
ibas_rel6_Technical_Description_Edition3.doc
The following figures show the system configuration for customer provision with broadband and narrowband services.
The red path shows the flow of the VoIP (Voice over Broadband), data and video traffic. The connection to the Aggregation Network is realized through the GbE I/F of the XPU Control Unit.
Aggregation Network VoIP, Data, Video Service Provider Network (IBAS MSAN) Access Network
BNG
Ethernet Network
XPU
ADSL LTU
IAD
TV
T
Splitter Laptop Voice (analogue) Phone (VoIP services)
Soft Switch
VoIP
NPU V5.2
POTS LTU
POTS
PSTN
Lifeline Phone
The blue path shows the lifeline POTS traffic flow. The connection to the Ethernet Aggregation Network can be realized through the Gb Ethernet I/F of the XPU control unit with the NPU subtended to the XPU. (1) The connection to the legacy PSTN network can be realized through the V5.2 interface of the NPU. (2)
Aggregation Network VoIP, Data, Video Service Provider Network (IBAS MSAN) Access Network
BNG
Ethernet Network
XPU
ADSL LTU
IAD
TV
T
Splitter Laptop Voice (analogue) Phone (VoIP Services)
Soft Switch
VoIP *
NPU V5.2
POTS LTU
POTS
PSTN
Lifeline Phone * The VoIP traffic can also be transferred through direct connection of the NPU to the Ethernet network.
(1) In case separate physical Ethernet connections are required for broadband and narrowband services, the NPU card can be directly connected to the Ethernet network. (2) The NPU-16E1/IPS model of NPU is required.
NOTE
In case of configuration with the MCIS, the MDF used should include splitters.
13
ibas_rel6_Technical_Description_Edition3.doc
5. Rack Solutions
Different rack solutions are available providing the following ADSL and POTS (Combo) ports capacities: 504 ADSL over PSTN Combo ports. The solution offers 504 ADSL and 504 POTS ports. 1008 ADSL over PSTN Combo ports. The solution offers 1008 ADSL and 1008 POTS ports. 2016 ADSL over PSTN Combo ports. The solution offers 2016 ADSL and 2016 POTS ports. 3024 ADSL over PSTN Combo ports. The solution offers 3024 ADSL and 3024 POTS ports. The aforementioned rack solutions are fully described herein after.
14
ibas_rel6_Technical_Description_Edition3.doc
The layout of the equipment to be mounted within a typical rack (H = 2200 mm, W = 600 mm, D = 300 mm) is shown below. A 28 U minimum rack space is required.
3U 1U PDF Empty Space
12 U
1U 1U 6U
3U 1U
Equipment PDF Mixed ADSL & PSTN Subrack Splitter Subrack Cable Manager
Scope Connection of the power lines (from the local dc distributor) and of the load cables. Connection to the subscriber network (for broadband and narrowband services provisioning). Separation of the ADSL and PSTN signals from the ADSLover-POTS channels. Arrangement of the ADSL, PSTN and Splitter Subracks cables.
Qty 1 1
1 2
15
ibas_rel6_Technical_Description_Edition3.doc
Ethernet Network
Up to 7 x GbE
7 ADSL72 LTU
VoIP
PSTN Network
7 POTS72 LTU
ADSL
MDF
Subscribers Network
16
ibas_rel6_Technical_Description_Edition3.doc
The configuration of the mixed ADSL and PSTN subrack is shown below:
Fan Tray P S F F C - P A X O D T S S L P 7 7 S 2 2 F F C X
P O T S 7 2
A D S L 7 2
D u m m y A P A P O D O D N X P S T S T P P a L S L S U U n 7 7 7 7 e 2 2 2 2 l 2
P O T S 7 2
A D S L 7 2
P O T S 7 2
A D S L 7 2
P O T S 7 2
D u m m A y D S P L a 7 n 2 e l 1
Qty 7 7 1 1 2 1
Continued on next page
17
ibas_rel6_Technical_Description_Edition3.doc
The configuration of the 8 slots splitter subrack is shown below (one slot is left empty for spare splitter card):
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
Unit Splitter
Qty 7
18
ibas_rel6_Technical_Description_Edition3.doc
The layout of the equipment to be mounted within a typical rack (H = 2200 mm, W = 600 mm, D = 300 mm) is shown below. A 42 U minimum rack space is required.
3U 1U PDF Empty Space
12 U
ADSL Subrack
1U 1U
12 U
PSTN Subrack
1U 1U 6U
3U 1U
Equipment PDF ADSL Subrack PSTN Subrack Splitter Subrack Cable Manager
Scope Connection of the power lines (from the local dc distributor) and of the load cables. Connection to the subscriber network (for broadband services provisioning). Connection to the subscriber network (for narrowband services provisioning). Separation of the ADSL and PSTN signals from the ADSL-overPOTS channels. Arrangement of the ADSL, PSTN and Splitter Subracks cables.
Qty 1 1 1 1 3
19
ibas_rel6_Technical_Description_Edition3.doc
Ethernet Network
Up to 7 x GbE
VoIP
MDF
Subscribers Network
PSTN Network
20
ibas_rel6_Technical_Description_Edition3.doc
Fan Tray P S F F C - A A X D D S S L L P 7 7 S 2 2 F F C X
A D S L 7 2
A D S L 7 2
A D S L 7 2
A D S L 7 2
D D D u u u m m m m m m y y A A A y D D D X P P S S S P P a a L L L a U n n 7 7 7 n e e 2 2 2 e l l l 1 2 1
A D S L 7 2
A D S L 7 2
A D S L 7 2
A D S L 7 2
A D S L 7 2
Unit ADSL72 XPU PSFFC-X Dummy Panel 1 (LTU) Dummy Panel 2 (CPU)
Qty 14 1 2 2 1
21
ibas_rel6_Technical_Description_Edition3.doc
Fan Tray P S F F C - P P X O O T T S S P 7 7 S 2 2 F F C X
P O T S 7 2
P O T S 7 2
P O T S 7 2
P O T S 7 2
P O N P P T P a a S U n n 7 e e 2 l l
D u m m y
D u m m y
D u m m y P O P T a S n 7 e 2 l
P O T S 7 2
P O T S 7 2
P O T S 7 2
P O T S 7 2
P O T S 7 2
P O T S 7 2
2 2 1
Unit POTS72 NPU PSFFC-X Dummy Panel 1 (LTU) Dummy Panel 2 (CPU)
Qty 14 1 2 1 2
22
ibas_rel6_Technical_Description_Edition3.doc
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
S p l i t t e r
Unit Splitter
Qty 14
23
ibas_rel6_Technical_Description_Edition3.doc
The layout of the equipment to be mounted within two typical racks (H = 2200 mm, W = 600 mm, D = 300 mm) is shown below. The two racks can be installed back-to-back with 600 mm total depth or side-by-side with 300 mm total depth. A 42 U minimum rack space is required at each rack.
Rack A
3U 1U PDF Empty Space 3U 1U
Rack B
PDF Empty Space
12 U
ADSL Subrack
12 U
ADSL Subrack
1U 1U
1U 1U
12 U
PSTN Subrack
12 U
PSTN Subrack
1U 1U 6U
1U 1U 6U
3U 1U
3U 1U
Equipment PDF ADSL Subrack PSTN Subrack Splitter Subrack Cable Manager
Scope Connection of the power lines (from the local dc distributor) and of the load cables. Connection to the subscriber network (for broadband services provisioning). Connection to the subscriber network (for narrowband services provisioning). Separation of the ADSL and PSTN signals from the ADSL-overPOTS channels. Arrangement of the ADSL, PSTN and Splitter Subracks cables.
Qty 2 2 2 2 6
NOTE
The racks should be installed at telecom rooms with proper air-conditioning system. If thats not feasible, INTRACOM TELECOM can provide you a specially designed cabinet of 800 mm depth with appropriate air-duct.
Continued on next page
24
ibas_rel6_Technical_Description_Edition3.doc
Ethernet Network
Up to 7 x GbE
VoIP
PSTN Network
Rack B
1 . .. 14 ADSL72 LTU
MDF
Subscribers Network
Ethernet Network
Up to 7 x GbE
VoIP
PSTN Network
25
ibas_rel6_Technical_Description_Edition3.doc
26
ibas_rel6_Technical_Description_Edition3.doc
NOTE
The following solution addresses to customers with splitters included in the MDF.
The layout of the equipment to be mounted within two typical racks (H = 2200 mm, W = 600 mm, D = 300 mm) is shown below. The two racks (Rack A and Rack B) are installed back-to-back. The total depth of the two racks will be 600 mm. A 46 U minimum rack space is required at each rack. The related ADSL and PSTN subracks are denoted with the same number (e.g. ADSL Subrack 3 and PSTN Subrack 3).
Rack A
3U 1U PDF Empty Space 3U 1U
Rack B
PDF Empty Space
12 U
ADSL Subrack 1
12 U
PSTN Subrack 1
1U 1U
1U 1U
12 U
PSTN Subrack 2
12 U
ADSL Subrack 2
1U 1U
1U 1U
12 U
ADSL Subrack 3
12 U
PSTN Subrack 3
1U 1U
1U 1U
Scope Connection of the power lines (from the local dc distributor) and of the load cables. Connection to the subscriber network (for broadband services provisioning). Connection to the subscriber network (for narrowband services provisioning). Arrangement of the ADSL, PSTN and Splitter Subracks cables.
Qty 2 3 3 6
NOTE
The racks should be installed at telecom rooms with proper air-conditioning system. If thats not feasible, INTRACOM TELECOM can provide you a specially designed cabinet of 800 mm depth with appropriate air-duct.
Continued on next page
27
ibas_rel6_Technical_Description_Edition3.doc
Rack A
1 .. . 14 ADSL72 LTU
Rack B
1 . .. ADSL 72 x 14 = 1008 ports PSTN 72 x 14 = 1008 ports 14 POTS72 LTU NPU PSTN Subrack 1 1 . .. PSTN 72 x 14 = 1008 ports MDF (*) ADSL 72 x 14 = 1008 ports 14 ADSL72 LTU XPU ADSL Subrack 2 1 . .. ADSL 72 x 14 = 1008 ports PSTN 72 x 14 = 1008 ports 14 POTS72 LTU NPU PSTN Subrack 3 V5.2 (16 x E1, 120 ) PSTN Network Up to 7 x GbE Ethernet Network V5.2 (16 x E1, 120 ) VoIP PSTN Network
Ethernet Network
Up to 7 x GbE
XPU
VoIP
NPU
Ethernet Network
Up to 7 x GbE
XPU
ADSL Subrack 3
VoIP
28
ibas_rel6_Technical_Description_Edition3.doc
6. Cabinet Solutions
Different cabinet solutions are available providing the following ports capacities: 360 ADSL over PSTN Combo ports and 360 PSTN ports 504 ADSL over PSTN Combo ports. The solution offers 504 ADSL and 504 POTS ports. The aforementioned cabinet solutions are fully described herein after.
29
ibas_rel6_Technical_Description_Edition3.doc
360 ADSL over PSTN Combo Ports & 360 PSTN Ports
Equipment layout
The layout of the equipment to be mounted within INTRACOM TELECOM INTRA S-27 outdoor cabinet (H = 1650 mm, W = 1190 mm, D = 690 mm) is shown below.
Mixed ADSL & PSTN Subrack
12 U
Generator Inlet
AC / DC PSU
Alarms Termin. Block
4U
ODF
Batteries MDF
Side Compartment
Side Compartment
Equipment AC PDF Power Meter Generator Inlet Alarms Termination Block ODF Mixed ADSL & PSTN Subrack AC / DC PSU Batteries MDF
Scope Connection of the ac power input. Measurement of the power consumption. Connection of ac generator (optional). Termination of cabinet internal and external alarms.
Qty 1 1 1 1
Connection of both network and telecom equipment optical cables. Connection to the subscriber network (for broadband and narrowband services provisioning). Connection of the power lines (from the AC PDF) and of the load cables. Power supply of the ADSL & PSTN Subrack in case of ac mains failure. Termination of the ADSL Combo Ports (splitters included), the PSTN Ports and the copper network.
1 1
1 4 18 module blocks
30
ibas_rel6_Technical_Description_Edition3.doc
360 ADSL over PSTN Combo Ports & 360 PSTN Ports,
Continued
Block diagram
31
ibas_rel6_Technical_Description_Edition3.doc
360 ADSL over PSTN Combo Ports & 360 PSTN Ports,
Continued
Mixed ADSL and PSTN subrack configuration
The configuration of the mixed ADSL and PSTN subrack is shown below:
Qty 5 10 1 1 2 1
32
ibas_rel6_Technical_Description_Edition3.doc
The layout of the equipment to be mounted within INTRACOM TELECOM INTRA S-27 outdoor cabinet (H = 1650 mm, W = 1190 mm, D = 690 mm) is shown below.
Mixed ADSL & PSTN Subrack
12 U
Generator Inlet
AC / DC PSU
Alarms Termin. Block
4U
ODF
Batteries MDF
Side Compartment
Side Compartment
Equipment AC PDF Power Meter Generator Inlet Alarms Termination Block ODF Mixed ADSL & PSTN Subrack AC / DC PSU Batteries MDF
Scope Connection of the ac power input. Measurement of the power consumption. Connection of ac generator (optional). Termination of cabinet internal and external alarms.
Qty 1 1 1 1
Connection of both network and telecom equipment optical cables. Connection to the subscriber network (for broadband and narrowband services provisioning). Connection of the power lines (from the AC PDF) and of the load cables. Power supply of the ADSL & PSTN Subrack in case of ac mains failure. Termination of the ADSL Combo Ports (splitters included) and the copper network.
1 1
1 4 18 module blocks
33
ibas_rel6_Technical_Description_Edition3.doc
The configuration of the mixed ADSL and PSTN subrack is shown below:
Qty 7 7 1 1 2 1
34
ibas_rel6_Technical_Description_Edition3.doc
7. Management
INTRACOM TELECOM offers an Integrated Management Solution with Network Management, Network Maintenance and Service Provisioning functionality for centrally managing iBAS MSAN networks. iBAS MSAN systems can be managed both locally and remotely through either CLI management or SNMP based management. The network management is performed through a suite of applications consisting of: BBMS for narrowband Element Management Systems (EMS) uNiMS for broadband Element Management Systems (EMS) ActionStreamer for service provisioning (optional)
35
ibas_rel6_Technical_Description_Edition3.doc
Management, Continued
Other options of managing iBAS MSAN systems
For the management of iBAS MSAN systems, INTRACOM TELECOM offers a software solution which enables the Operator to set up, configure and monitor the systems either locally or remotely via SNMP, CLI or LCT. CLI is used for ADSL local or remote operation and maintenance and offers extensive configuration and monitoring capabilities via efficient and simple compound commands that are internally split into multiple individual commands. CLI implements FCPS functions. LCT is used for POTS local or remote operation and maintenance and offers extensive configuration and monitoring capabilities via efficient and simple Windows-based Graphical User Interface. SNMP may be used for direct connection to 3rd party NMS / OSS systems.
36
ibas_rel6_Technical_Description_Edition3.doc
ITU-T G.992.1 (ADSL G.dmt), all Annexes ITU-T G.992.2 (ADSL G.lite), all Annexes ITU-T G.992.3 (ADSL2), Annexes A, L, M ITU-T G.992.5 (ADSL2+), Annexes A, M
Features
ATM SARing Auto-sensing encapsulation On VC Full Bridging functionality with 802.1Q support Traffic handling and QoS for up to 8 queues per port with rate limiting L2 / L3 Security Features Packet Filtering and Suppressing PPPoA to PPPoE Interworking
IPoA to IPoE Tunneling Full PPP and DHCP with Intermediate Agent Enhanced INP support DELT and SELT line test support Autonomous thermal shutdown functionality
37
ibas_rel6_Technical_Description_Edition3.doc
xPU Blade
Ethernet features
Ethernet switching functionality, full layer 2 (Ethernet bridging) and layer 3 functionality IEEE 802.1ad Provider Bridges [VLAN Stacking (Q in Q)] IEEE 802.1d-2004 IEEE 802.1q and IEEE 802.1q-REV (including 1:n VLANs) IEEE 802.1p RSTP IEEE 802.1w Rapid Spanning Tree Protocol
MSTP IEEE 802.1q-2003 Multiple Spanning Tree Protocol DSL Forum TR-101 (in conjunction with the ADSL-72 LTUs)
QoS features
Full QoS functionality Strict Priority Queuing (for VoIP applications) Enhanced number of QoS policers and classifiers Priority-aware full-duplex PAUSE functionality, allowing standard IEEE 802.3x PAUSE to be used for best effort flow control while avoiding headof-line (HOL) blocking effects on high-priority, low-latency traffic Per VLAN IEEE 802.1p priority retagging
Security features
MAC anti-spoofing denial of service prevention CAM table flooding protection MAC table per interface (active MAC address limiting per interface) Broadcast storm control (limits broadcast traffic in large scale Layer 2 networks) MAC Access Lists
Continued on next page
38
ibas_rel6_Technical_Description_Edition3.doc
Massively scalable per-port-confined VLAN swapping scheme (allows VLANs to retain link-level significance while still allowing forwarding and QoS classification in each instance) Massively scalable source or destination MAC address-based VLAN allocation scheme Four-stage priority-aware hierarchical shaper per port, enabling shaping to synchronous line rates while limiting buffer requirements on up to four levels of the attached devices and / or network equipment Additional support of IEEE 802.1ad Provider Bridges (VLAN Stacking) for extended VLAN addressability and transparency
Other features
Multicasting: - IGMP v2 snooping with proxy reporting and zap log supporting IGMP Access Lists (White or Black notation available) Local Log Buffers, Syslog server support Extensive logging, precise timing via Real-Time Clock, clock synchronization with NTP or SNTP servers Full support of TACACS+ for provision of separate authentication, authorization and accounting services Bandwidth monitoring per Interface
Management capabilities
Command Line Interface (CLI) for local or remote management Element management via uNiMS offering Fault Management, Performance Management, Security, Remote Scheduled Software Upgrades and Network Topology Connection to Fault, Performance & Inventory OSS systems via uNiMS Element Manager SNMP/Java North-bound interfaces Connection to Service Management OSS/BSS systems via ActionStreamer Automatic Service Provisioning Middleware offering real time service activation in bulk or single mode and rapid integration with new or legacy OSS/BSS systems due to its Service Oriented Architecture (SOA) Direct connection to OSS Fault Management systems via SNMP v2 Direct connection to OSS centralized logging systems via embedded SYSLOG server
39
ibas_rel6_Technical_Description_Edition3.doc
POTS-72 Blade
Line remote power feeding adjusted to long (4 to 5 km) or short (up to 1,5 km) loops for power consumption minimization per subscriber High driving capability per port (up to 5 RENs for short loops and up to 3 RENs for long loops) On-board power supply unit (for the cards operating voltages) protected against shorts or circuit overloads DTMF or pulse dialling detection per port Ringing signal generation per port Polarity reversal support per port Caller ID generation per port CLIP on CW Metering tone (12 kHz / 16 kHz) generation Line testing per port according to GR-909 and GR-844 (1) standards (foreign voltage detection, resistance and capacitance measurements) Remote control and management of the blade through the Central Control Unit High speed PCM bus carrying voice and signalling data to / from the Central Control Unit Hot insertion / extraction in / from the chassis Ports protection against overvoltages and lightning (secondary protection) Pots line characteristics software configurable according to customers demands and in compliance to ITU-T Q.552, ETSI EG 201 188, ETSI EG 201 185
40
ibas_rel6_Technical_Description_Edition3.doc
NPU Blade
E1 traffic
Available only in the NPU-16E1/IPS type of blade. V5.2 multilink (ETS 300 347) G.703 2048 kbit/s short haul with 120 Ohm line termination impedance * HDB3 line coding 12 dB maximum cable attenuation CRC-4 multiframe / doubleframe framing (G.704 compliant) or none
* For 75 Ohm line termination impedance, a 120 Ohm to 75 Ohm conversion panel is required.
VoIP signalling
PSTN signalling (H.248 (Megaco) / SIP) H.248.1 v2, ETSI ES 283 002 v1.1.1 (2005-08) SIP v2 (RFC 3261), ETSI TS 183 043
Multiple VoIP Codecs support (G.711 PCM A-law or u-law, G.729A/B, G.726, G.723.1) Echo Cancellation (G.168) Voice Activity Detection, Silence Suppression Fax / Modem functionality: - Fax / Modem Pass Through (G.711) - Fax / Modem Autonomous / Soft Switch Controlled - Fax relay over IP (T.38) Packet Loss Concealment (PLC) support
Ethernet features
Management capabilities
LCT windows-based graphical application for local or remote management Element management via BBMS offering Fault, Configuration, Performance, Security, Remote Scheduled Software Updates and Network Topology Connection to Fault, Performance & Inventory OSS systems via BBMS Element Manager SNMP/Java North-bound interfaces Connection to Service Management OSS/BSS systems via ActionStreamer Automatic Service Provisioning Middleware offering real time service activation in bulk or single mode and rapid integration with new or legacy OSS/BSS systems due to its Service Oriented Architecture (SOA) Direct connection to OSS systems via SNMP v1 & v2
41
ibas_rel6_Technical_Description_Edition3.doc
Operating DC Voltage Maximum Total Power Consumption for pure broadband services provisioning Maximum Total Power Consumption for pure narrowband services provisioning Typical Total Power Consumption for pure narrowband services provisioning Maximum Power Consumption per card
FANT-X PSFFC-X xPU-8SG NPU-16E1/IPS / NPU-IPS ADSL-72/2+A / ADSL-72/2+B POTS-72_TDM
48 V / -60 V (-40,5 V to -72 V) HCIS: 1810 W MCIS: 652 W HCIS: 1946 W MCIS: 634 W HCIS: 756 W MCIS: 294 W 30 W 2W 80 W 64 W 106 W (1) 132 W (1) (2)
(1) All ports active, long loops and high environment temperature
42
ibas_rel6_Technical_Description_Edition3.doc
Mechanical Specifications
Dimensions (H x W x D)
HCIS/M: 621,5 mm x 482,6 mm x 284,7 mm (24,47 in x 19 in x 11,21 in) HCIS/M-X: 492 mm x 482,6 mm x 271,9 mm (19,37 in x 19 in x 10,7 in) MCIS: 177 mm x 482,6 mm x 271,9 mm (6,97 in x 19 in x 10,7 in) 14 slots Splitter Subrack: 265,9 mm x 482,6 mm x 192,5 mm (10,47 in x 19 in x 7,58 in) 8 slots Splitter Subrack: 265,9 mm x 482,6 mm x 138,5 mm (10,47 in x 19 in x 5,45 in)
Weight
HCIS/M: 18 kg (empty) ~44 kg (fully equipped) HCIS/M-X: 13 kg (empty) ~39 kg (fully equipped) MCIS: 8,8 kg (empty) ~18 kg (fully equipped) 14 slots Splitter Subrack: 3,5 kg (empty) ~16 kg (fully equipped) 8 slots Splitter Subrack: 3 kg (empty) ~11 kg (fully equipped)
Environmental Specifications
Operating Temperature Range: Relative Humidity (RH): Storage and Transportation Temperature -25 C to +55 C (ETSI EN 300 019-2-3, Class 3.3) 93% at +30 C (steady state) (ETSI EN 300 019-2-3, Class 3.3) -40 C to +70 C (ETSI EN 300 019-2-2, Class T2.3)
43
ibas_rel6_Technical_Description_Edition3.doc
WAN Interfaces
WAN Interfaces
xPU-8sg Control Unit: - 8 x GbE interfaces (1000BASE-X with SFP modules, IEEE 802.3), for WAN uplink connections, SFP MSA and SFF-8472 compliant xPU-4/4G Control Unit: - 4 x GbE electrical interfaces (10/100/1000BASE-T at RJ-45 receptacles, IEEE 802.3), for WAN uplink connections - 4 x GbE interfaces (1000BASE-X with SFP modules, IEEE 802.3), for WAN uplink connections
Ports Capacity
HCIS: up to 1152 x ADSL2+ interfaces (Annexes A, L, M) or 1008 POTS interfaces or 504 combo (ADSL+POTS) interfaces MCIS: up to 360 x ADSL2+ interfaces (Annexes A, L, M) or 288 POTS interfaces or 144 combo (ADSL+POTS) interfaces All interfaces available on the corresponding LTUs blades front panels
Splitters
Filters SP-72P14 Splitter Unit Low Pass Filters (LPF) matched to option A and B of ETSI 101-952-1-1 Suitable for installation in the 14 slots Splitter Subrack. Affords two groups of three receptacles each, at the front panel, for connection to the ADSL-72/2+A and POTS-72 blades and one group of three receptacles, back accessible, for termination of 72 line ADSL-overPOTS signals Suitable for installation in the 8 slots Splitter Subrack. Affords two groups of three receptacles each, at the front panel, for connection to the ADSL-72/2+A and POTS-72 blades and one group of three receptacles, also at the front panel, for termination of 72 line ADSLover-POTS signals
Continued on next page
44
ibas_rel6_Technical_Description_Edition3.doc
I / O ports
Inputs Four input pairs to connect external switching devices (sensors, switches etc.). All inputs are internally optocoupled. Two output pairs (dry contacts) to connect external system alarm monitoring circuitry. The outputs are rated at 1 A max and 220 V ac or dc.
Continued on next page
Outputs
45
ibas_rel6_Technical_Description_Edition3.doc
Management Interfaces
FE interface (10/100BASE-TX, IEEE 802.3), for local or remote outband management connection RS-232 interface (V.24 subset), for local outband management connection GbE #1 traffic interface (1000BASE-X with SFP module, IEEE 802.3), can be optionally used for inband management transmission, in case of xPU-8sg Control Unit Management interfaces Anyone of the eight GbE traffic interfaces (GbE 1 to 4: 10/100/1000BASE-T at RJ-45 receptacles, IEEE 802.3, GbE 5 to 6: 1000BASE-X with SFP module, IEEE 802.3), can be optionally used for inband management transmission, in case of xPU-4/4G/N Control Unit (*) All interfaces available on the Central Control blade front panel CLI interface for local or remote management of ADSL72 LCT windows-based graphical application for local or remote management of POTS72 SNMP v2 for remote element/network management of ADSL72 SNMP v1 or v2 for remote element/network management of POTS72 POTS Element management via BBMS offering Fault, Configuration, Performance, Security, Remote Scheduled Software Updates and Network Topology ADSL Element management via uNiMS offering Fault Management, Performance Management, Security, Remote Scheduled Software Upgrades and Network Topology Connection to Fault, Performance & Inventory OSS systems via uNiMS & BBMS Element Managers North-bound interfaces Connection to Service Management OSS/BSS systems via ActionStreamer Automatic Service Provisioning Middleware offering real time service activation in bulk or single mode and rapid integration with new or legacy OSS/BSS systems due to its Service Oriented Architecture (SOA)
Management options
(*) From the eight GbE interfaces only one can be used for inband management
each time. The selection of the interface is performed as follows: If the RSTP protocol is supported, the RSTP protocol selects the interface to be used for the inband management traffic.
If the RSTP protocol is not supported, the first interface that is up starting from
GbE1 is selected. Continued on next page
46
ibas_rel6_Technical_Description_Edition3.doc
Electromagnetic compatibility and Radio spectrum Matters (ERM) Telecommunication network equipment; Electromagnetic Compatibility (EMC) requirements Resistibility of telecommunication equipment installed in a telecommunications centre to overvoltages and overcurrents Resistibility of access network equipment to overvoltages and overcurrents Radio disturbance of Information technology equipment Information technology equipment - Safety RoHS compliant Environmental conditions and tests for telecommunications equipment Part 1-3 Asymmetric Digital Subscriber Line (ADSL) transceivers Extended bandwidth ADSL2 (ADSL2+) Media Access Control (MAC) Bridges Virtual Bridged Local Area Networks Carrier sense multiple access with collision detection (CSMA / CD) access method and physical layer specifications
ITU-T K.20 (basic level) ITU-T K.45 (basic level) EN 55022 Class A EN 60950-1 2002/95/EC ETSI EN 300 019-1-3 V2.1.2 Class 3.5 ITU-T G.992.5 ITU-T G.992.5 Annex L ITU-T G.992.5 Annex M IEEE 802.1d IEEE 802.1q IEEE 802.3
47
ibas_rel6_Technical_Description_Edition3.doc
10. Abbreviations
CapEx CLI CO CPE FCPS INP LTU MSAN NGN OpEx ROI SNMP VC VLAN VoD WAN
Capital Expenditures Command Line Interface Central Office Customer Premises Equipment Fault, Configuration, Performance, Security Impulse Noise Protection Line Termination Unit Multi Service Access Node Next Generation Network Operational Expenditures Return On Investment Simple Network Management Protocol Virtual Circuit Virtual Local Area Network Video on Demand Wide Area Network