UNIT 1

ABOUT NTPC
Indias largest power company, NTPC was set up in 1975 to accelerate power development in India. NTPC is emerging as a diversified power major with presence in the entire value chain of the power generation business. Apart from power generation, which is the mainstay of the company, NTPC has already ventured into consultancy, power trading, ash utilization and coal mining. NTPC ranked 341st in the 2010, Forbes Global 2000 ranking of the Worlds biggest companies. NTPC became a Maharatna company in May, 2010, one of the only four companies to be awarded this status. The total installed capacity of the company is 39,174 MW (including JVs) with 16 coal based and 7 gas based stations, located across the country. In addition under JVs, 7 stations are coal based & another station uses naphtha/LNG as fuel. The company has set a target to have an installed power generating capacity of 1, 28,000 MW by the year 2032. The capacity will have a diversified fuel mix comprising 56% coal, 16% Gas, 11% Nuclear and 17% Renewable Energy Sources(RES) including hydro. By 2032, non-fossil fuel based generation capacity shall make up nearly 28% of NTPCs portfolio. NTPC has been operating its plants at high efficiency levels. Although the company has 17.75% of the total national capacity, it contributes 27.40% of total power generation due to its focus on high efficiency.

In October 2004, NTPC launched its Initial Public Offering (IPO) consisting of 5.25% as fresh issue and 5.25% as offer for sale by Government of India. NTPC thus became a listed company in November 2004 with the Government holding 89.5% of the equity share capital. In February 2010, the Shareholding of Government of India was reduced from 89.5% to 84.5% through Further Public Offer. The rest is held by Institutional Investors and the Public.

STRATEGIES OF NTPC

TECHNOLOGICAL INITIATIVES Introduction of steam generators (boilers) of the size of 800 MW. Integrated Gasification Combined Cycle (IGCC) Technology. Launch of Energy Technology Centre -A new initiative for development of technologies with focus on fundamental R&D. The company sets aside up to 0.5% of the profits for R&D. Roadmap developed for adopting Clean Development. Mechanism to help get/earn Certified Emission Reduction.

CORPORATE SOCIAL RESPONSIBILITY As a responsible corporate citizen NTPC has taken up number of CSR initiatives. NTPC Foundation formed to address Social issues at national level NTPC has framed Corporate Social Responsibility Guidelines committing up to0.5% of net profit annually for Community Welfare. The welfare of project affected persons and the local population around NTPC projects are taken care of through well drawn Rehabilitation and Resettlement policies. The company has also taken up distributed generation for remote rural areas.

PARTNERING GOVERNMENT IN VARIOUS INITIATIVES Consultant role to modernize and improvise several plants across the country. Disseminate technologies to other players in the sector. Consultant role Partnership in Excellence Program for improvement of PLF of 15 Power Stations of SEBs. Rural Electrification work under Rajiv Gandhi Garmin Vidyutikaran.

ENVIRONMENT MANAGEMENT All stations of NTPC are ISO 14001 certified. Various groups to care of environmental issues. The Environment Management Group. Ash Utilization Division. Afforestation Group. Centre for Power Efficiency & Environment Protection. Group on Clean Development Mechanism. NTPC is the second largest owner of trees in the country after the Forest department.

VISION
To be the worlds largest and best power producer, powering Indias growth.

MISSION
Develop and provide reliable power, related products and services at competitive prices, integrating multiple energy sources with innovative and eco-friendly technologies and contribute to society.

CORE VALUES BE COMMITTED


B E C O M M I T T E D Business Ethics Environmentally & Economically Sustainable Customer Focus Organizational & Professional Pride Mutual Respect & Trust Motivating Self & others Innovation & Speed Total Quality for Excellence Transparent & Respected Organization Enterprising Devoted

JOURNEY OF NTPC

NTPC ENVIRONMENT POLICY


NTPC is committed to the environment, generating power at minimal environmental cost and preserving the ecology in the vicinity of the plants. NTPC has undertaken massive a forestation in the vicinity of its plants. Plantations have increased forest area and reduced barren land. The massive a forestation by NTPC in and around its Ramagundam Power station (2600 MW) have contributed reducing the temperature in the areas by about 3c. NTPC has also taken proactive steps for ash utilization. In 1991, it set up Ash Utilization Division A. "Centre for Power Efficiency and Environment Protection- CENPEE" has been established in NTPC with the assistance of United States Agency for International Development- USAID. CENPEEP is efficiency oriented, eco-friendly and eco-nurturing initiative - a symbol of NTPC's concern towards environmental protection and continued commitment to sustainable power development in India. As a responsible corporate citizen, NTPC is making constant efforts to improve the socio-economic status of the people affected by its projects. Through its Rehabilitation and Resettlement programs, the company endeavors to improve the overall socio economic status Project Affected Persons. NTPC was among the first Public Sector Enterprises to enter into a Memorandum of Understanding-MOU with the Government in 1987-88. NTPC has been placed under the 'Excellent category' (the best category) every year since the MOU system became operative. Harmony between man and environment is the essence of healthy life and growth. Therefore, maintenance of ecological balance and a pristine environment has been of utmost importance to NTPC. It has been taking various measures discussed below for mitigation of environment pollution due to power generation. NTPC is the second largest owner of trees in the country after the Forest department.

As early as in November 1995, NTPC brought out a comprehensive document entitled "NTPC Environment Policy and Environment Management System". Amongst the guiding principles adopted in the document is companys proactive approach to environment, optimum utilization of equipment, adoption of latest technologies and continual environment improvement. The policy also envisages efficient utilization of resources, thereby minimizing waste, maximizing ash utilization and providing green belt all around the plant for maintaining ecological balance. Environment Management, Occupational Health and Safety Systems: NTPC has actively gone for adoption of best international practices on environment, occupational health and safety areas. The organization has pursued the Environmental Management System (EMS) ISO 14001 and the Occupational Health and Safety Assessment System OHSAS 18001 at its different establishments. As a result of pursuing these practices, all NTPC power stations have been certified for ISO 14001 & OHSAS 18001 by reputed national and international Certifying Agencies. Pollution Control systems: While deciding the appropriate technology for its projects, NTPC integrates many environmental provisions into the plant design. In order to ensure that NTPC complies with all the stipulated environment norms, various state-of-the-art pollution control systems / devices as discussed below have been installed to control air and water pollution. Electrostatic Precipitators: The ash left behind after combustion of coal is arrested in high efficiency Electrostatic Precipitators (ESPs) and particulate emission is controlled well within the stipulated norms. The ash collected in the ESPs is disposed to Ash Ponds in slurry form. Flue Gas Stacks: Tall Flue Gas Stacks have been provided for wide dispersion of the gaseous emissions (SOX, NOX etc.) into the atmosphere.

Low-NOX Burners: In gas based NTPC power stations, NOX emissions are controlled by provision of Low- NOX Burners (Dry or wet type) and in coal fired stations, by adopting best combustion practices. Neutralization Pits: Neutralization pits have been provided in the Water Treatment Plant (WTP) for pH correction of the Effluents before discharge into Effluent Treatment Plant (ETP) for further treatment and use. Coal Settling Pits / Oil Settling Pits: In these Pits, coal dust and oil are removed from the effluents emanating from the Coal Handling Plant (CHP), coal yard and Fuel Oil Handling areas before discharge into ETP. DE & DS Systems: Dust Extraction (DE) and Dust Suppression (DS) systems have been installed in all coal fired power stations in NTPC to contain and extract the fugitive dust released in the Coal Handling Plant (CHP). Cooling Towers: Cooling Towers have been provided for cooling the hot Condenser cooling water in closed cycle, Condenser Cooling Water (CCW) Systems. This helps in reduction in thermal pollution and conservation of fresh water. Ash Dykes & Ash Disposal systems: Ash ponds have been provided at all coal based stations except Dadri where Dry Ash Disposal System has been provided. Ash Ponds have been divided into lagoons and provided with garlanding arrangement for changeover of the ash slurry feed points for even filling of the pond and for effective settlement of the ash particles. Ash in slurry form is discharged into the lagoons where ash particles get settled from the slurry and clear effluent water is discharged from the ash pond. The discharged effluents conform to standards specified by CPCB and the same is regularly monitored. At its Dadri Power Station, NTPC has set up a unique system for dry ash collection and disposal facility with Ash Mound formation. This has been envisaged for the first time in Asia which has resulted in progressive development of green belt besides far less requirement of land and less water requirement as compared to the wet ash disposal system. Ash Water Recycling System: Further, in a number of NTPC stations, as a proactive measure, Ash Water Recycling System (AWRS) has been provided. In the AWRS, the effluent from ash pond is circulated back to the station for further ash sluicing to the ash pond. This helps in savings of fresh water requirements for transportation of ash from the plant.

The ash water recycling system has already been installed and is in operation at Ramagundam, Simhadri, Rihand, Talcher Kaniha, Talcher Thermal, Kahalgaon, Korba and Vindhyachal. The scheme has helped stations to save huge quantity of fresh water required as make-up water for disposal of ash. Dry Ash Extraction System (DAES): Dry ash has much higher utilization potential in ash-based products (such as bricks, aerated autoclaved concrete blocks, concrete, Portland pozzolana cement, etc.). DAES has been installed at Unchahar, Dadri, Simhadri, Ramagundam, Singrauli, Kahalgaon, Farakka, Talcher Thermal, Korba, Vindhyachal, Talcher Kaniha and BTPS. Liquid Waste Treatment Plants & Management System: The objective of industrial liquid effluent treatment plant (ETP) is to discharge lesser and cleaner effluent from the power plants to meet environmental regulations. After primary treatment at the source of their generation, the effluents are sent to the ETP for further treatment. The composite liquid effluent treatment plant has been designed to treat all liquid effluents which originate within the power station e.g. Water Treatment Plant (WTP), Condensate Polishing Unit (CPU) effluent, Coal Handling Plant (CHP) effluent, floor washings, service water drains etc. The scheme involves collection of various effluents and their appropriate treatment centrally and recirculation of the treated effluent for various plant uses. NTPC has implemented such systems in a number of its power stations such as Ramagundam, Simhadri, Kayamkulam, Singrauli, Rihand, Vindhyachal, Korba, Jhanor Gandhar, Faridabad, Farakka, Kahalgaon and Talcher Kaniha. These plants have helped to control quality and quantity of the effluents discharged from the stations. Sewage Treatment Plants & Facilities: Sewage Treatment Plants (STPs) sewage treatment facilities have been provided at all NTPC stations to take care of Sewage Effluent from Plant and township areas. In a number of NTPC projects modern type STPs with Clarifloculators, Mechanical Agitators, sludge drying beds, Gas Collection Chambers etc. have been provided to improve the effluent quality. The effluent quality is monitored regularly and treated effluent conforming to the prescribed limit is discharged from the station. At several stations treated effluents of STPs are being used for horticulture purpose.

10

UNIT 2
ABOUT BTPS
BADARPUR THERMAL POWER STATION was established on 1973 and it was the part of Central Government. On 01/04/1978 it was given as No Loss No Profit Plant of NTPC. Since then operating performance of NTPC has been considerably above the national average. The availability factor for coal stations has increased from 85.03 % in 1997-98 to 90.09 % in 200607, which compares favorably with international standards. The PLF has increased from 75.2% in1997-98 to 89.4% during the year 2006-07 which is the highest since the inception of NTPC. Badarpur Thermal Power Station started with a single 95 MW unit. There were 2 more units (95 MW each) installed in next 2 consecutive years. Now it has total five units with total capacity of 720 MW. Ownership of BTPS was transferred to NTPC with effect from 01.06.2006 through GOIs Gazette Notification. The power is supplied to a 220 KV network that is a part of the northern grid. The ten circuits through which the power is evacuated from the plant are: 1. Mehrauli 2. Okhla 3. Ballabgarh 4. Indraprastha 5. UP (Noida) 6. Jaipur

11

Given below are the details of unit with the year theyre installed.

12

STATION LOCATION Badarpur is situated only 20 km away from Delhi. The plant is located on the left side of the National Highway (Delhi- Mathura Road) and it comprises of 430 hectares (678 acres) bordered by the Agra Canal from east and by Mathura-Delhi Road from West. However, the area for ash disposal is done in the Delhi Municipal limit and is maintained with the help of Delhi Development Authority. The plant is also close to the project of 220 kV Double Circuit Transmission line between the IP station and Ballabgarh Cooling Water is obtained from Agra Canal for the cooling system. Additional 60 cusecs channel has also been constructed parallel to the Agra Canal so as to obtain uninterrupted water supply during the slit removing operation in Agra Canal.

13

UNIT 3
OPERATION OF A POWER PLANT
BASIC PRINCIPLE As per FARADAYs Law-Whenever the amount of magnetic flux linked with a circuit changes, an EMF is produced in the circuit. Generator works on the principle of producing electricity. To change the flux in the generator turbine is moved in a great speed with steam. To produce steam, water is heated in the boilers by burning the coal. In a Badarpur Thermal PowerStation, steam is produced and used to spin a turbine that operates a generator. Water is heated, turns into steam and spins a steam turbine which drives an electrical generator. After it passes through the turbine, the steam is condensed in a condenser; this is known as a Rankine cycle. The electricity generated at the plant is sent to consumers through high-voltage power lines The Badarpur Thermal Power Plant has Steam Turbine-Driven Generators which has a collective capacity of 705MW. The fuel being used is Coal which is supplied from the Jharia Coal Field in Jharkhand. Water supply is given from the Agra Canal.

14

BASIC STEPS OF ELECTRICITY GENERATION


The basic steps in the generation of electricity from coal involves following steps: Coal to steam Steam to mechanical power Mechanical power to electrical power

15

COAL TO ELECTRICITY: BASICS

Coal to steam: Coal from the coal wagons is unloaded in the coal handling plant. This coal is transported up to the raw coal bunkers with the help of belt conveyors. Coal is transported to Bowl mills by Coal Feeders. The coal is pulverized in the Bowl mill, where it is ground to powder form. The mill consists of a round metallic table on which coal particles fall. This table is rotated with the help of a motor. There are three large steel rollers, which are spaced 120 apart. When there is no coal, these rollers do not rotate but when the coal is fed to the table it packs up between roller and the table and thus forces the rollers to rotate. Coal is crushed by the crushing action between the rollers and the rotating table. This crushed coal is taken away to the furnace through coal pipes with the help of hot and cold air mixture from P.A. fan. P.A. fan takes atmospheric air, a part of which is sent to air-preheaters for heating while a part goes directly to the mill for temperature control. Atmospheric air from F.D. fan is heated in the air heaters and sent to the furnace as combustion air. Water from the boiler feed pump passes through economizer and reaches the boiler drum. Water from the drum passes through down comers and goes to the bottom ring header. Water from the bottom ring header is divided to all the four sides of the furnace. Due to heat and density difference, the water rises up in the water wall tubes. Water is partly converted to steam as it rises up in the furnace. This steam and water mixture is again taken to the boiler drum where the steam is separated from water.

16

Water follows the same path while the steam is sent to superheaters for superheating. The superheaters are located inside the furnace and the steam is superheated (540C) and finally it goes to the turbine. Flue gases from the furnace are extracted by induced draught fan, which maintains balance draught in the furnace (-5 to -10 mm of wel) with forced draught fan. These flue gases emit their heat energy to various superheaters in the pent house and finally pass through air preheaters and goes to electrostatic precipitators where the ash particles are extracted. Electrostatic precipitator consists of metal plates, which are electrically charged. Ash particles are attracted on to these plates, so that they do not pass through the chimney to pollute the atmosphere. Regular mechanical hammer blows cause the accumulation of ash to fall to the bottom of the precipitator where they are collected in a hopper for disposal. Steam to Mechanical Power From the boiler, a steam pipe conveys steam to the turbine through a stop valve (which can be used to shut-off the steam in case of emergency) and through control valves that automatically regulate the supply of steam to the turbine. Stop valve and control valves are located in a steam chest and a governor, driven from the main turbine shaft, operates the control valves to regulate the amount of steam used. (This depends upon the speed of the turbine and the amount of electricity required from the generator). Steam from the control valves enters the high pressure cylinder of the turbine, where it passes through a ring of stationary blades fixed to the cylinder wall. These act as nozzles and direct the steam into a second ring of moving blades mounted on a disc secured to the turbine shaft. The second ring turns the shafts as a result of the force of steam. The stationary and moving blades together constitute a stage of turbine and in practice many stages are necessary, so that the cylinder contains a number of rings of stationary blades with rings of moving blades arranged between them. The steam passes through each stage in turn until it reaches the end of the highpressure cylinder and in its passage some of its energy is changes into mechanical energy. The steam leaving the high pressure cylinder goes back to the boiler for reheating and returns by a further pipe to the intermediate pressure cylinder. Here it passes through another series of stationary and moving blades. Finally, the steam is taken to the low pressure cylinders, each of which enters at the center flowing outwards in opposite directions through the rows of turbine blades through as arrangement called the double flow to extremities of the cylinder. As the steam gives up its heat energy to drive the turbine, its temperature and pressure fall and it expands. Because of this expansion the blades are much larger and longer towards the low pressure ends of the turbine. Mechanical power to Electrical power:
17

As the blades of turbine rotate, the shaft of the generator, which is coupled to that of the turbine, also rotates. It results in rotation of the coil of the generator, which causes induced electricity to be produced.

FACTORS AFFECTING THERMAL CYLCE EFFICIENCY


Thermal cycle efficiency is affected by following: Initial steam pressure. Initial steam temperature. Whether reheat is used or not, and if used reheat and temperature. Condenser pressure. Regenerative feed water heating.

18

UNIT 4
PARTS OF A POWER PLANT

The various parts are listed below: 1. Cooling tower 2. Cooling water pump 3. Transmission line (3-phase) 4. Unit transformer (3-phase) 5. Electric generator (3-phase) 6. Low pressure turbine 7. Condensate extraction pump 8. Condenser 9. Intermediate pressure turbine 10. Steam governor valve 11. High pressure turbine 12. Deaerator
19

13. Feed heater 14. Coal conveyor 15. Coal hopper 16. Pulverized fuel mill 17. Boiler drum 18. Ash hopper 19. Super heater 20. Forced draught fan 21. Reheater 22. Air intake 23. Economizer 24. Air preheater 25. Precipitator 26. Induced draught fan 27. Flue Gas 1. COOLING TOWER

Cooling towers are heat removal devices used to transfer process waste heat to the atmosphere. Cooling towers may either use the evaporation of water to remove process heat and cool the working fluid to near the wet-bulb air temperature or in the case of closed circuit dry cooling towers rely solely on air to cool the working fluid to near the dry-bulb air temperature. Common applications include cooling the circulating water used in oil refineries, chemical plants, power stations and building cooling. The towers vary in size from small roof-top units to very large hyperboloid structures that can be up to 200 meters tall and 100 meters in diameter, or rectangular structures that can be over 40 meters tall and 80 meters long. Smaller towers are normally factory-built, while larger ones are constructed on site. The absorbed heat is rejected to the atmosphere by the evaporation of some of the cooling water in mechanical forced-draft or induced Draft towers or in natural draft hyperbolic shaped cooling towers as seen at most nuclear power plants. 2. COOLING WATER PUMP

It pumps the water from the cooling tower which goes to the condenser. 3. THREE PHASE TRANSMISSION LINE

Three phase electric power is a common method of electric power transmission. It is a type of polyphase system mainly used to power motors and many other devices. A three phase system uses less conductive material to transmit electric power than equivalent single phase, two phase,

20

or direct current system at the same voltage. In a three phase system, three circuits reach their instantaneous peak values at different times. Taking current in one conductor as the reference, the currents in the other two are delayed in time by one-third and two-third of one cycle .This delay between phases has the effect of giving constant power transfer over each cycle of the current and also makes it possible to produce a rotating magnetic field in an electric motor. At the power station, an electric generator converts mechanical power into a set of electric currents, one from each electromagnetic coil or winding of the generator. The current are sinusoidal functions of time, all at the same frequency but offset in time to give different phases. In a three phase system the phases are spaced equally, giving a phase separation of one-third of one cycle. Generators output at a voltage that ranges from hundreds of volts to 30,000 volts. 4. UNIT TRANSFORMER (3-PHASE)

At the power station, transformers step-up the voltage to be suitable for transmission. After numerous further conversions in the transmission and distribution network the power is finally transformed to the standard mains voltage (i.e. the household voltage). The power may already have been split into single phase at this point or it may still be three phase. Where the step-down is 3 phase, the output of this transformer is usually star connected with the standard mains voltage being the phase-neutral voltage. Another system commonly seen in North America is to have a delta connected secondary with a center tap on one of the windings supplying the ground and neutral. This allows for 240 V three phase as well as three different single phase voltages( 120 V between two of the phases and neutral , 208 V between the third phase ( or wild leg) and neutral and 240 V between any two phase) to be available from the same supply. 5. ELECTRICAL GENERATOR

An Electrical generator is a device that converts kinetic energy to electrical energy, generally using electromagnetic induction. The task of converting the electrical energy into mechanical energy is accomplished by using a motor. The source of mechanical energy maybe water falling through the turbine or steam turning a turbine (as is the case with thermal power plants). There are several classifications for modern steam turbines. Steam turbines are used in our entire major coal fired power stations to drive the generators or alternators, which produce electricity. The turbines themselves are driven by steam generated in "boilers or "steam generators" as they are sometimes called. Electrical power stations use large steam turbines driving electric generators to produce most (about 86%) of the worlds electricity. These centralized stations are of two types: fossil fuel power plants and nuclear power plants. The turbines used for electric power generation are most often directly coupled to their-generators .As the generators must rotate at
21

constant synchronous speeds according to the frequency of the electric power system, the most common speeds are 3000 r/min for 50 Hz systems, and 3600 r/min for 60 Hz systems. Most large nuclear sets rotate at half those speeds, and have a 4-pole generator rather than the more common 2-pole one. 6. LOW PRESSURE TURBINE

Energy in the steam after it leaves the boiler is converted into rotational energy as it passes through the turbine. The turbine normally consists of several stages with each stages consisting of a stationary blade (or nozzle) and a rotating blade. Stationary blades convert the potential energy of the steam into kinetic energy and direct the flow onto the rotating blades. The rotating blades convert the kinetic energy into impulse and reaction forces, caused by pressure drop, which results in the rotation of the turbine shaft. The turbine shaft is connected to a generator, which produces the electrical energy. Low Pressure Turbine (LPT) consists of 4x2 stages. After passing through Intermediate Pressure Turbine steam is passed through LPT which is made up of two parts- LPC REAR & LPC FRONT. As water gets cooler here it gathers into a HOTWELL placed in lower parts of turbine. 7. CONDENSATION EXTRACTION PUMP

A Boiler feed water pump is a specific type of pump used to pump water into a steam boiler. The water may be freshly supplied or returning condensation of the steam produced by the boiler. These pumps are normally high pressure units that use suction from a condensate return system and can be of the centrifugal pump type or positive displacement type. Construction and operation: Feed water pumps range in size up to many horsepower and the electric motor is usually separated from the pump body by some form of mechanical coupling. Large industrial condensate pumps may also serve as the feed water pump. In either case, to force the water into the boiler, the pump must generate sufficient pressure to overcome the steam pressure developed by the boiler. This is usually accomplished through the use of a centrifugal pump. Feed water pumps usually run intermittently and are controlled by a float switch or other similar levelsensing device energizing the pump when it detects a lowered liquid level in the boiler. Some pumps contain a two-stage switch. As liquid lowers to the trigger point of the first stage, the pump is activated. If the liquid continues to drop, (perhaps because the pump has failed, its supply has been cut off or exhausted, or its discharge is blocked) the second stage will be triggered. This stage may switch off the boiler equipment (preventing the boiler from running dry and overheating), trigger an alarm, or both. 8. CONDENSER

22

The steam coming out from the Low Pressure Turbine (a little above its boiling pump) is brought into thermal contact with cold water (pumped in from the cooling tower) in the condenser, where it condenses rapidly back into water, creating near Vacuum-like conditions inside the condenser chest. 9. INTERMEDIATE PRESSURE TURBINE

Intermediate Pressure Turbine (IPT) consists of 11 stages. When the steam has been passed through HPT it enters into IPT. IPT has two ends named as FRONT & REAR. Steam enters through front end and leaves from Rear end. 10. STEAM GOVERNOR VALVE

Steam locomotives and the steam engines used on ships and stationary applications such as power plants also required feed water pumps. In this situation, though, the pump was often powered using a small steam engine that ran using the steam produced by the boiler a means had to be provided, of course, to put the initial charge of water into the boiler (before steam power was available to operate the steam-powered feed water pump).The pump was often a positive displacement pump that had steam valves and cylinders at one end and feed water cylinders at the other end; no crankshaft was required. In thermal plants, the primary purpose of surface condenser is to condense the exhaust steam from a steam turbine to obtain maximum efficiency and also to convert the turbine exhaust steam into pure water so that it may be reused in the steam generator or boiler as boiler feed water. By condensing the exhaust steam of a turbine at a pressure below atmospheric pressure, the steam pressure drop between the inlet and exhaust of the turbine is increased, which increases the amount heat available for conversion to mechanical power. Most of the heat liberated due to condensation of the exhaust steam is carried away by the cooling medium (water or air) used by the surface condenser. Control valves are valves used within industrial plants and elsewhere to control operating conditions such as temperature, pressure, flow and liquid level by fully or partially opening or closing in response to signals received from controllers that compares a set point to a process variable whose value is provided by sensors that monitor changes in such conditions. The opening or closing of control valves is done by means of electrical, hydraulic or pneumatic systems. 11. HIGH PRESSURE TURBINE

Steam coming from Boiler directly feeds into HPT at a temperature of 540C and at a pressure of 136 kg/cm2. Here it passes through 12 different stages due to which its temperature goes down to 329C and pressure as 27 kg/cm2. This line is also called as CRH COLD REHEAT LINE. It is now passed to a REHEATER where its temperature rises to 540C and called as HRH-HOT REHEATED LINE. 12. DEAERATOR
23

A Deaerator is a device for air removal and used to remove dissolved gases (an alternate would be the use of water treatment chemicals) from boiler feed water to make it non-corrosive. A deaerator typically includes a vertical domed deaeration section as the deaeration boiler feed water tank. A Steam generating boiler requires that the circulating steam, condensate, and feed water should be devoid of dissolved gases, particularly corrosive ones and dissolved or suspended solids. The gases will give rise to corrosion of the metal. The solids will deposit on the heating surfaces giving rise to localized heating and tube ruptures due to overheating. Under some conditions it may give rise to stress corrosion cracking. Deaerator level and pressure must be controlled by adjusting control valves the level by regulating condensate flow and the pressure by regulating steam flow. If operated properly, most deaerator vendors will guarantee that oxygen in the deaerated water will not exceed 7 ppb by weight (0.005 cm3/L) 13. FEED WATER HEATER

A Feed water heater is a power plant component used to pre-heat water delivered to a steam generating boiler. Preheating the feed water reduces the irreversibility involved in steam generation and therefore improves the thermodynamic efficiency of the system. This reduces plant operating costs and also helps to avoid thermal shock to the boiler metal when the feed water is introduced back into the steam cycle. In a steam power (usually modeled as a modified Rankine cycle), feed water heaters allow the feed water to be brought up to the saturation temperature very gradually. This minimizes the inevitable irreversibility associated with heat transfer to the working fluid (water). 14. COAL CONVEYOR

Coal conveyors are belts which are used to transfer coal from its storage place to Coal Hopper. A belt conveyor consists of two pulleys, with a continuous loop of material- the conveyor Belt that rotates about them. The pulleys are powered, moving the belt and the material on the belt forward. Conveyor belts are extensively used to transport industrial and agricultural material, such as grain, coal, ores etc. 15. COAL HOPPER

Coal Hoppers are the places which are used to feed coal to Fuel Mill. It also has the arrangement of entering Hot Air at 200C inside it which solves our two purposes: (i) If our Coal has moisture content then it dries it so that a proper combustion takes place. (ii) It raises the temperature of coal so that its temperature is more near to its Ignite Temperature so that combustion is easy. 16. PULVERIZER FUEL MILL
24

A pulveriser is a device for grinding coal for combustion in a furnace in a fossil fuel power plant. 17. BOILER DRUM

Steam Drums are a regular feature of water tube boilers. It is reservoir of water/steam at the top end of the water tubes in the water-tube boiler. They store the steam generated in the water tubes and act as a phase separator for the steam/water mixture. The difference in densities between hot and cold water helps in the accumulation of the hotter-water/and saturated steam into steam drum. Made from high-grade steel (probably stainless) and its working involve temperature of 390C and pressure well above 350psi (2.4MPa). The separated steam is drawn out from the top section of the drum. Saturated steam is drawn off the top of the drum. The steam will re-enter the furnace in through a super heater, while the saturated water at the bottom of steam drum flows down to the mud-drum /feed water drum by down comer tubes accessories include a safety valve, water level indicator and fuse plug. 18. ASH HOPPER

A steam drum is used in the company of a mud-drum/feed water drum which is located at a lower level. So that it acts as a sump for the sludge or sediments which have a tendency to accumulate at the bottom. 19. SUPER HEATER

A Super heater is a device in a steam engine that heats the steam generated by the boiler again increasing its thermal energy. Super heaters increase the efficiency of the steam engine, and were widely adopted. Steam which has been superheated is logically known as superheated steam; non- superheated steam is called saturated steam or wet steam. Super heaters were applied to steam locomotives in quantity from the early 20th century, to most steam vehicles, and also stationary steam engines including power stations. 20. FORCE DRAUGHT FAN

External fans are provided to give sufficient air for combustion. The forced draught fan takes air from the atmosphere and, warms it in the air preheater for better combustion, injects it via the air nozzles on the furnace wall. 21. REHEATER

Reheater is a heater which is used to raise the temperature of steam which has fallen from the intermediate pressure turbine.

25

22.

AIR INTAKE

Air is taken from the environment by an air intake tower which is fed to the fuel. 23. ECONOMIZERS

Economizer, or in the UK economizer, are mechanical devices intended to reduce energy consumption, or to perform another useful function like preheating a fluid. The term economizer is used for other purposes as well-Boiler, power plant, heating, ventilating and air-conditioning. In boilers, economizer are heat exchange devices that heat fluids , usually water, up to but not normally beyond the boiling point of the fluid. Economizers are so named because they can make use of the enthalpy and improving the boilers efficiency. They are devices fitted to a boiler which save energy by using the exhaust gases from the boiler to preheat the cold water used to fill it (the feed water). Modern day boilers, such as those in cold fired power stations, are still fitted with economizer which is decedents of Greens original design. In this context there are turbines before it is pumped to the boilers. A common application of economizer in steam power plants is to capture the waste heat from boiler stack gases (flue gas) and transfer thus it to the boiler feed water thus lowering the needed energy input , in turn reducing the firing rates to accomplish the rated boiler output . Economizer lower stack temperatures which may cause condensation of acidic combustion gases and serious equipment corrosion damage if care is not taken in their design and material selection. 24. AIR PREHEATER

Air preheater is a general term to describe any device designed to heat air before another process (for example, combustion in a boiler). The purpose of the air preheater is to recover the heat from the boiler flue gas which increases the thermal efficiency of the boiler by reducing the useful heat lost in the flue gas. As a consequence, the flue gases are also sent to the flue gas stack (or chimney) at a lower temperature allowing simplified design of the ducting and the flue gas stack. It also allows control over the temperature of gases leaving the stack. 25. PRECIPITATOR

An Electrostatic precipitator (ESP) or electrostatic air cleaner is a particulate device that removes particles from a flowing gas (such as air) using the force of an induced electrostatic charge. Electrostatic precipitators are highly efficient filtration devices, and can easily remove fine particulate matter such as dust and smoke from the air steam. ESPs continue to be excellent devices for control of many industrial particulate emissions, including smoke from electricitygenerating utilities (coal and oil fired), salt cake collection from black liquor boilers in pump mills, and catalyst collection from fluidized bed catalytic crackers from several hundred thousand ACFM in the largest coal-fired boiler applications. The original parallel plate-Weighted wire design (described above) has evolved as more efficient (and robust) discharge electrode designs, today focus is on rigid discharge electrodes to which many sharpened spikes are
26

attached , maximizing corona production. Transformer rectifier systems apply voltages of 50100 Kilovolts at relatively high current densities. Modern controls minimize sparking and prevent arcing, avoiding damage to the components. Automatic rapping systems and hopper evacuation systems remove the collected particulate matter while on line allowing ESPs to stay in operation for years at a time. 26. INDUCED DRAUGHT FAN

The induced draft fan assists the FD fan by drawing out combustible gases from the furnace, maintaining a slightly negative pressure in the furnace to avoid backfiring through any opening. At the furnace outlet and before the furnace gases are handled by the ID fan, fine dust carried by the outlet gases is removed to avoid atmospheric pollution. This is an environmental limitation prescribed by law, which additionally minimizes erosion of the ID fan. 27. FLUE GAS STACK

A Flue gas stack is a type of chimney, a vertical pipe, channel or similar structure through which combustion product gases called flue gases are exhausted to the outside air. Flue gases are produced when coal, oil, natural gas, wood or any other large combustion device. Flue gas is usually composed of carbon dioxide (CO2) and water vapour as well as nitrogen and excess oxygen remaining from the intake combustion air. It also contains a small percentage of pollutants such as particulates matter, carbon mono oxide, nitrogen oxides and sulphur oxides. The flue gas stacks are often quite tall, up to 400 meters (1300 feet) or more, so as to disperse the exhaust pollutants over a greater area and thereby reduce the concentration of the pollutants to the levels required by government's environmental policies and regulations. The flue gases are exhausted from stoves, ovens, fireplaces or other small sources within residential abodes, restaurants, hotels through other stacks which are referred to as chimneys.

27

UNIT 5
CYCLES AT POWER STATION

COAL CYLCE. FEED WATER CYCLE. STEAM CYCLE. CONDENSATE CYCLE. FLUE GAS CYLCE. PRIMARY AIR CYCLE. SECONDARY AIR CYCLE.

28

COAL CYCLE
COAL FROM JHARIA MINES

RAILWAY WAGON

WAGON TIPPLER

COAL STOCK YARD

CRUSHER HOUSE

R.C. BUNKER

R.C. FEEDER

PULVERIZER

TO FURNACE
29

FEED WATER CYCLE


DE-AERATOR

BOILER FEED PUMP

H.P. HEATER - 5

H.P. HEATER - 6

H.P. HEATER - 7

FEED WATER LINE

ECONOMIZER

BOILER DRUM

DOWN COMER

WATER WALL

WATER PLATTENS

UPRISER HEADER

30

STEAM CYCLE
FROM BOILER DRUM

L.T. SUPERHEATER

PLATTEN SUPERHEATER

MAIN STEAM LINE

H.P. TURBINE

C.R.H. LINES

RE-HEATER

H.R.H. LINES

I.P. TURBINE

L.P. TURBINE

TO CONDENSER

31

CONDENSATE CYCLE
FROM A.P. TURBINE

CONDENSER

CONDENSATE PUMP

EJECTOR

GLAND STEAM COOLER

L.P.H. - 1

L.P.H. - 2

G.S.C. - 2

L.P.H. - 2

L.P.H. - 3

L.P.H. - 4

DEAREATOR
32

FLUE GAS CYCLE

FROM FURNACE 1150C WATER PLATTENS 1120C

PLALLENTS SUPER HEATER


1007C PRE HEATER 788C FINAL SUPER HEATER 497C L.T. SUPER HEATER 476C ECONOMISER 362C AIR PRE HEATER 141C ELECTROSTATIC PRECIPITATOR

140C
I.D. FAN 140C CHIMNEY

TO ATMOSPHERE
33

PRIMARY AIR CYCLE

FROM ATMOSPHERE

P.A. FAN

COLD P.A. HEATER

AIR HEATER

SEAL AIR FAN

HOT P.A. HEATER

PULVERISER/BOWL MILL

TO FURNACE

34

SECONDARY AIR CYCLE

FROM ATMOSPHERE

FORCED DRAUGHT FAN

STEAM COIL AIR PREHEATER

AIR PRE HEATER

WIND BOX

TO FURNACE

35

CONTROL & INSTRUMENTATION


INTRODUCTION C&I LABS CONTROL & MONITORING MECHENISM PRESSURE MONITORING TEMPERATURE MONITORING FLOW MEASUREMENT CONTROL VALVES

36

INTRODUCTION
This division basically calibrates various instruments and takes care of any faults occur in any of the auxiliaries in the plant. Instrumentation can be well defined as a technology of using instruments to measure and control the physical and chemical properties of a material. C&I LABS Control and Instrumentation Department has following labs: Manometry Lab. Protection and Interlocks Lab. Automation Lab. Electronics Lab. Water Treatment Plant. Furnaces Safety Supervisory System Lab

OPERATION AND MAINTAINANCE Control and Instrumentation Department has following Control Units: 1. Unit Control Board. 2. Main Control Board. 3. Analog & Digital Signal Control. 4. Current Signal Control. This department is the brain of the plant because from the relays to transmitters followed by the electronic computation chipsets and recorders and lastly the controlling circuitry, all fall under this.

37

A View of Control Room at BTPS

1. MANOMETRY LAB Transmitters It is used for pressure measurements of gases and liquids, its working principle is that the input pressure is converted into electrostatic capacitance and from there it is conditioned and amplified. It gives an output of 4-20 ma DC. It can be mounted on a pipe or a wall. For liquid or steam measurement transmitters is mounted below main process piping and for gas measurement transmitter is placed above pipe. Manometer Its a tube which is bent, in U shape. It is filled with a liquid. This device corresponds to a difference in pressure across the two limbs.

38

Bourdon pressure gauge Its an oval section tube. Its one end is fixed. It is provided with a pointer to indicate the pressure on a calibrated scale. It is of 2 types: (a) Spiral type: for Low pressure measurement. (b) Helical Type: for High pressure measurement. While selecting Pressure Gauge these parameters should keep in mind: 1. Accuracy 2. Safety 3. Utility 4. Price ACCURACY: Higher Accuracy implies Larger Dial Size for accuracy of small and readable pressure scale increments. SAFETY: While selecting Pressure Gauge it should consider that Gauge Construction Material should be chemically compatible with the environment either inside or outside it. UTILITY: It should keep it mind that range of the Gauge should be according to our need else Overpressure Failure may occur resulting in damage of Gauge. PRICE: Lager the Gauges Dial size larger would be our price. Better Gauges Construction material also increases the cost. So they must be chosen according to our need. 2. PROTECTION AND INTERLOCKING Interlocking: It is basically interconnecting two or more equipment so that if one equipment fails other one can perform the tasks. This type of interdependence is also created so that equipment connected together are started and shut down in the specific sequence to avoid damage. For protection of equipment tripping are provided for all the equipment. Tripping can be considered as the series of instructions connected through OR GATE, which trips the circuit. The main equipment of this lab are relay and circuit breakers. Some of the instrument uses for protection are:
39

Relay: It is a protective device. It can detect wrong condition in electrical circuits by constantly measuring the electrical quantities flowing under normal and faulty conditions. Some of the electrical quantities are voltage, current, phase angle and velocity. 2. FUSES it is a short piece of metal inserted in the circuit, which melts when heavy current flows through it and thus breaks the circuit. Usually silver is used as a fuse material because: a. The coefficient of expansion of silver is very small. As a result no critical fatigue occurs and thus the continuous full capacity normal current ratings are assured for the long time. b. The conductivity of the silver is unimpaired by the surges of the current that produces temperatures just near the melting point. c. Silver fusible elements can be raised from normal operating temperature to vaporization quicker than any other material because of its comparatively low specific heat. Miniature Circuit Breaker: They are used with combination of the control circuits to: (a) Enable the staring of plant and distributors. (b) Protect the circuit in case of a fault. In consists of current carrying contacts, one movable and other fixed. When a fault occurs the contacts separate and are is stuck between them. There are three types of trips: (i) Manual Trip. (ii) Thermal Trip. (iii) Short Circuit Trip Protection and Interlock System: (i) High tension control circuit for high tension system the control system is excited by separate D.C supply. For starting the circuit conditions should be in series with the starting coil of the equipment to energize it. Because if even a single condition is not true then system will not start. (ii) Low tension control circuit for low tension system the control circuits are directly excited from the 0.415 KV A.C supply. The same circuit achieves both excitation and tripping. Hence the tripping coil is provided for emergency tripping if the interconnection fails.
40

3. AUTOMATION LAB: This lab deals in automating the existing equipment and feeding routes. Earlier, the old technology dealt with only (DAS) Data Acquisition System and came to be known as primary systems. The modern technology or the secondary systems are coupled with (MIS) Management Information System. But this lab universally applies the pressure measuring instruments as the controlling force. However, the relays are also provided but they are used only for protection and interlocks. 4. PYROMETRY LAB: Liquid in glass thermometer: Mercury in the glass thermometer boils at 340 C which limits the range of temperature that can be measured. It is L shaped thermometer which is designed to reach all inaccessible places. Ultra violet censor: This device is used in furnace and it measures the intensity of ultra violet rays there and according to the wave generated which directly indicates the temperature in the furnace. Thermocouples: This device is based on SEEBACK and PELTIER effect. It comprises of two junctions at different temperature. Then the emf is induced in the circuit due to the flow of electrons. This is an important part in the plant. RTD (Resistance Temperature Detector): It performs the function of thermocouple basically but the difference is of a resistance. In this due to the change in the resistance the temperature difference is measured. In this lab, also the measuring devices can be calibrated in the oil bath or just boiling water (for low range devices) and in small furnace (for high range devices). 5. FURNACE SAFETY AND SUPERVISORY SYSTEM LAB: This lab has the responsibility of starting fire in the furnace to enable the burning of coal. For first stage coal burners are in the front and rear of the furnace and for the second and third stage corner firing is employed. Unburnt coal is removed using forced draft or induced draft fan. The temperature inside the boiler is 1100C and its heights 18 to 40 m. It is made up of mild steel. An ultra violet sensor is employed in furnace to measure the intensity of ultra violet rays inside the furnace and according to it a signal in the same order of same mV is generated which directly indicates the temperature of the furnace. For firing the furnace a 10 KV spark plug is operated for ten seconds over a spray of diesel fuel and pre-heater air along each of the feeder-mills. The furnace has six feeder mills each separated by warm air pipes fed from forced draft fans. In first stage indirect firing is employed that is feeder
41

mills are not fed directly from coal but are fed from three feeders but are fed from pulverized coalbunkers. The furnace can operate on the minimum feed from three feeders but under no circumstances should anyone be left out under operation, to Prevent creation of pressure different with in the furnace, which threatens to blast it. 6. ELECTRONICS LAB: This lab undertakes the calibration and testing of various cards. It houses various types of analytical instruments like oscilloscopes, integrated circuits, cards auto analyzers etc. Various processes undertaken in this lab are: (i) Transmitter converts mV to mA. (ii) Auto analyzer purifies the sample before it is sent to electrodes. It extracts the magnetic portion. Annunciation cards: They are used to keep any parameter like temperature etc. within limits. It gets a signal if parameter goes beyond limit. It has a switching transistor connected to relay that helps in alerting the UCB.

42

CONTROL & MONITORING MECHANISMS


There are basically two types of Problems faced in a Power Plant: (i) Metallurgical. (ii) Mechanical. Mechanical Problem can be related to Turbines that is the max speed permissible for a turbine is3000 rpm so speed should be monitored and maintained at that level. Metallurgical Problem can be view as the max Inlet Temperature for Turbine is 1060 C so temperature should be below the limit. Monitoring of all the parameters is necessary for the safety of both: (i) Employees. (ii) Machines. So the Parameters to be monitored are: (a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) Speed. Temperature. Current. Voltage. Pressure. Eccentricity. Flow of Gases. Vacuum Pressure. Valves. Level. Vibration.

PRESSURE MONITORING: Pressure can be monitored by three types of basic mechanisms (a) Switches. (b) Gauges. (c) Transmitter type. For gauges we use Bourdon tubes. The Bourdon Tube is a non-liquid pressure measurement device. It is widely used in applications where inexpensive static pressure measurements are needed. A typical Bourdon tube contains a curved tube that is open to external pressure input on one end and is coupled mechanically to an indicating needle on the other end, as shows schematically below.

43

Typical Bourdon Tube Pressure Gages: For Switches pressure switches are used and they can be used for digital means of monitoring as switch being ON is referred as high and being OFF is as low. All the monitored data is converted to either Current or Voltage parameter. The Plant standard for current and voltage are as under: Voltage : 0 10 Volts range Current : 4 20 milli-Amperes

We use 4mA as the lower value so as to check for disturbances and wire breaks. Accuracy of such systems is very high. ACCURACY: 0.1 % Programmable Logic Circuits (PLCs) are used in the process as they are the heart of Instrumentation.

44

TEMPERATURE MONITORING: We can use Thermocouples or RTDs for temperature monitoring. Normally RTDs are used for low temperatures. Thermocouple selection depends upon two factors: (a) Temperature Range (b) Accuracy Required Normally used Thermocouple is K Type Thermocouple: In this we use Chromel (Nickel-Chromium Alloy) / Alumel (Nickel-Aluminium Alloy) as two metals. This is the most commonly used general purpose thermocouple. It is inexpensive and, owing to its popularity, available in a wide variety of probes. They are available in the200C to +1200C range. Sensitivity is approximately 41 V/C. RTDs are also used but not in protection systems due to vibrational errors. We pass a constant current through the RTD. So that if R changes then the Voltage also changes RTDs used in Industries are Pt100 And Pt1000 Pt100: 0C 100 ( 1 = 2.5 0C ) Pt1000: 0C - 1000 Pt1000 is used for higher accuracy. The gauges used for Temperature measurements are mercury filled Temperature gauges. For Analog medium thermocouples are used and for Digital medium Switches are used which are basically mercury switches. FLOW MEASUREMENT: Flow measurement does not signify much and is measured just for metering purposes and for monitoring the processes. Rotameters: A Rotameter is a device that measures the flow rate of liquid or gas in a closed tube. It is occasionally misspelled as 'Rotometer'. It belongs to a class of meters called variable area meters, which measure flow rate by allowing the cross sectional area the fluid travels through to vary, causing some measurable effect. A rotameter consists of a tapered tube, typically made of glass, with a float inside that is pushed up by flow and pulled down by gravity. At a higher flow rate more area (between the float and the tube) is needed to accommodate the flow, so the float rises. Floats are made in many different shapes, with spheres and spherical ellipses being the most common. The float is shaped so that it
45

rotates axially as the fluid passes. This allows you to tell if the float is stuck since it will only rotate if it is not. For Digital measurements Flap system is used. For Analog measurements we can use the following methods: (i) (ii) (iii) (iv) (v) (vi) Flow meters. Venturimeters/Orifice meters. Turbines. Mass flow meters (Oil level). Ultrasonic Flow Meters. Magnetic Flow meter (water level )

Selection of flow meter depends upon the purpose, accuracy and liquid to be measured so different types of meters used. Turbine type: They are simplest of all. They work on the principle that on each rotation of the turbine a pulse is generated and that pulse is counted to get the flow rate. Venturimeters:

46

Referring to the diagram, using Bernoulli's equation in the special case of incompressible fluids (such as the approximation of a water jet), and the theoretical pressure drop at the constriction would be given by (/2)(v22- v12). And we know that rate of flow is given by: Flow = k (D.P) Where DP is Differential Pressure or the Pressure Drop. Control valves: A valve is a device that regulates the flow of substances (either gases, fluidized solids, slurries, or liquids) by opening, closing, or partially obstructing various passageways. Valves are technically pipe fittings, but usually are discussed separately. Valves are used in a variety of applications including industrial, military, commercial, residential, transportation. Plumbing valves are the most obvious in everyday life, but many more are used. Some valves are driven by pressure only; they are mainly used for safety purposes in steam engines and domestic heating or cooking appliances. Others are used in a controlled way, like in Otto cycle engines driven by a camshaft, where they play a major role in engine cycle control. Many valves are controlled manually with a handle attached to the valve stem. If the handle is turned a quarter of a full turn (90) between operating positions, the valve is called a quarter-turn valve. Butterfly valves, ball valves, and plug valves are often quarter-turn valves. Valves can also be controlled by devices called actuators attached to the stem. They can be electromechanical actuators such as an electric motor or solenoid, pneumatic actuators which are controlled by air pressure, or hydraulic actuators which are controlled by the pressure of a liquid such as oil or water. So there are basically three types of valves that are used in power industries besides the handle valves. They are: Pneumatic valves: They are air or gas controlled which is compressed to turn or move them Hydraulic valves: They utilize oil in place of Air as oil has better compression. Motorized valves: These valves are controlled by electric motors.

47

FURNACE SAFEGUARD SUPERVISORY SYSTEM: FSSS is also called as Burner Management System (BMS). It is a microprocessor based programmable logic controller of proven design incorporating all protection facilities required for such system. Main objective of FSSS is to ensure safety of the boiler. The 95 MW boilers are indirect type boilers. Fire takes place in front and in rear side. Thats why its called front and rear type boiler. The 210 MW boilers are direct type boilers (which means that HSD is in direct contact with coal) firing takes place from the corner. Thus it is also known as corner type boiler. Igniter system: Igniter system is an automatic system, it takes the charge from 110kv and this spark is brought in front of the oil guns, which spray aerated HSD on the coal for coal combustion. There is a 5 minute delay cycle before igniting, this is to evacuate or burn the HSD. This method is known as PURGING. Pressure switch: Pressure switches are the devices that make or break a circuit. When pressure is applied, the switch under the switch gets pressed which is attached to a relay that makes or break the circuit. Time delay can also be included in sensing the pressure with the help of pressure valves. Examples of pressure valves: (i) Manual valves (tap). (ii) Motorized valves (actuator) - works on motor action. (iii) Pneumatic valve (actuator) - works due to pressure of compressed air. (iv) Hydraulic valve.

48