Sie sind auf Seite 1von 12

A

Electric Power / Controls

2 kW DFIG LABORATORY KIT, MODEL 8013-A, with optional equipment by OPAL-RT

GENERAL DESCRIPTION
Lab-Volt has created a Doubly-Fed Induction Generator training kit as an extension of its popular 2- kW EMS product line. This kit is design for customers that are interested in further experimentation with doubly-fed induction generators used in wind turbines. This kit includes the new Four-Quadrant Dynamometer, Model 8540, which can be interfaced easily with a computer in order to emulate wind blowing on a wind turbine rotor (Wind Emulator). The generator used in the kit is a special version of our existing Wound-Rotor Induction Generator. This special version has a rotor voltage of 624 V (line-to-line). The kit also includes two IGBT Chopper/Inverter, Model 8857-1, to convert energy in both directions with a Line Inductors, Model 8374-A. Finally, a Three-Phase Power Supply, Model 8525-2, is used for connection to a standard three-phase network. Each of these modules is described in more detail in the following pages of this document. This laboratory kit DOES NOT include the DFIG controller. Lab-Volt is providing this kit as a hardware solution only and the controller must be provided by the customer. The 2 kW DFIG Laboratory Kit has already been integrated with success with OPAL-RTs OP5600/8660 Real-Time HIL Controller and Data Acquisition System. Contact OPAL-RT at www.opal-rt.com/2kw-doubly-fedinduction-generator-kit for more information on their control solution.

(732) 938-2000 / 800-LAB-VOLT, FAX: (732) 774-8573, E-MAIL: us@labvolt.com (418) 849-1000 / 800-LAB-VOLT, FAX: (418) 849-1666, E-MAIL: ca@labvolt.com INTERNET: http://www.labvolt.com

2 kW DFIG LABORATORY KIT MODEL 8013-A LIST OF EQUIPMENT


QTY DESCRIPTION ORDERING NUMBER
1

1 1 1 1 1 1 1 2 1 1 1 1

Three-Module Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8131-00 Resistive Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8311-00 Line Inductors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8374-A0 Three-Phase Wound-Rotor Induction Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8505-A0 Wiring Module for Wound-Rotor Induction Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8506-A0 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8525-20 Four-Quadrant Dynamometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8540-00 IGBT Chopper/Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8857-10 Three-Phase Splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8895-00 Coupler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8943-00 Connection Leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8951-Q0 PC Communication Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88362-00

OPTIONAL EQUIPMENT
DESCRIPTION ORDERING NUMBER

Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8134-20 Inductive Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8321-00 Capacitive Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8331-00 Enclosure / Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8840-00 Current/Voltage Isolator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9056-B0 HIL Simulator Controller & Data Acquisition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPAL-RT OP5600 Signal Conditioning Module Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPAL-RT OP8660

MODULE DESCRIPTION
Model 8131 Three-Module Workstation The Three-Module Workstation consists of a single row of three full-height compartments that can accommodate up to three full-size EMS modules or six half-size EMS modules. The Three-Module Workstation shares the following features with the Mobile Workstation: a front mounted release lever and a safety locking device for each compartment and holes in the rear panel of the workstation with removable cover plates. The Three-Module Workstation requires assembly. A diagram is provided with the workstation to facilitate assembly.

TABLE OF CONTENTS

The Three-Module Workstation, Model 8131, serves the same purpose as the Mobile Workstation, Model 8110, but it has no storage cabinet nor pull-out work surface.This workstation is intended for use on a bench and is fitted with wooden feet to protect the bench top (not supplied).

General Description . . . . . . . . . . . . . . . . . . . . . . . . . List of Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . Optional Equipment . . . . . . . . . . . . . . . . . . . . . . . . . Module Description . . . . . . . . . . . . . . . . . . . . . . . . . Optional Equipment Description . . . . . . . . . . . . . . . Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 2 2 2 6 8

The kit is currently only available at 120/208 V 60 Hz in English. For other system configurations or further information, please contact Lab-Volt Services (services@labvolt.com)

Model 8311 Resistive Load

Model 8505-A0 Three-Phase Wound-Rotor Induction Motor

The Resistive Load, Model 8311, is equipped with 9 wire-wound power resistors. Each resistor is identified by a schematic symbol, the resistance value, as well as the current that will flow through it when connected to a nominal voltage power source. Each resistor is within 5% tolerance of the stated resistance value. Model 8374-A0 Line Inductors

The Line Inductors is a set of three inductors used to filter the power out of the IGBT Chopper/Inverter to the AC network.

The Three-Phase Wound-Rotor Induction Motor consists of a 4-pole machine rated at 2 kW. Each phase of the stator winding is accessible via the connection module to allow wye or delta connections. The rotor is wye connected to four slip rings to give access to all windings, including neutral. The winding dimensions permit the study of operation as a wound-rotor induction motor, a frequency converter, a phase-shifter, a position controller, a variable-coupling single-phase transformer, a three-phase transformer, and an asynchronous induction generator. The machine also has three search coils permitting observation of the flux distribution at one pole of the stator, at one tooth, and at the full-pitch of the rotor.

2 kW DFIG LABORATORY KIT MODEL 8013-A


Model 8506-A0 Wiring Module for Wound-Rotor Induction Motor with a 5-prong, twist-lock plug and line cap, feeds the module. A mechanical interlock on the line cap prevents the removal of an energized Power Supply from its locked position in the workstation. The Power Supply requires a 3-phase, wye-connected, 5-wire service installation. An appropriate wall outlet is shipped with each Power Supply so that site power can be properly terminated to receive the power cord. In addition to the 3-phase legs and the neutral, a separate copper ground provides proper grounding for the Power Supply chassis and workstation cabinets, thus ensuring added safety for students using the equipment. The Power Supply provides fixed and variable AC and DC voltage sources all terminated with 4-mm safety jacks. They can be used simultaneously, up to a total load current equal to the rating of the fixed 3-phase output. Independent circuit breakers, reset at the front panel, protect the Power Supply input and outputs. Indicator lamps monitor the presence of input voltage in each phase. When a phase leg of the site power service is out, the lamp goes off to reflect this condition. A voltmeter, connected through a selector switch, monitors the outputs. Model 8540 Four-Quadrant Dynamometer

The Wiring Module for Wound-Rotor Induction Motor consists of a connection module. It provides connection access to the Three-Phase Wound-Rotor Induction Motor from the workstation through a flexible connecting cable. The module has ten 4-mm color-coded safety jacks for the power windings and six 2-mm jacks for the search coils. Jacks of different sizes prevent accidental connections between power windings and search coils. Model 8525-20 Power Supply

The Power Supply module is the primary component of the system. All associated equipment is powered by this power supply. A flexible, 5-wire power cord, terminated

The Four-Quadrant Dynamometer, Model 8540, is a new model which can be integrated to the Lab-Volt 2-kW Electromechanical Training System, Model 8013. This model can act as a prime mover or as a dynamometer, depending on user preference, and it can easily be coupled to any motor and generator from the Lab-Volt 2kW product line. The Four-Quadrant Dynamometer consists of a squirrel cage induction motor with an encoder feedback. The motor is driven by a closed-loop vector drive which is coupled to a touch-screen HMI (Human-Machine Interface). This interface enables the user to select the mode of operation (Speed or Torque mode) and to set either the speed (rpm) and direction or the output torque (Nm or lbft). The interface displays the main parameters of operation in real-time (Voltage, Current, Torque, Speed, Frequency).

Electrical connections between the vector drive and the motor are made through jumpers on the front panel. This makes the separation of both components simple and allows the motor or the vector drive to be used independently in other experimentations. The vector drive is well protected against abuse. The vector drive will stop if a problem occurs and the LCD will show the current alarm along with its description. The user is then able to reset the alarm and resume normal operation. The model can also be interfaced with a computer for monitoring and control. Model 8857-10 IGBT Chopper/Inverter

Model 8895-00 Three-Phase Splitter

The Three-Phase Splitter, Model 8895, is required when users need to connect their own equipment in addition to the Four Quadrant Dynamometer, Model 8540 at a workstation equipped with only one three phase wall outlet. Model 88362 PC Communication Cable

The IGBT Chopper/Inverter, Model 8857-1, consists of 7 insulated-gate bipolar transistors (IGBT) mounted in a half-size EMS module. Six IGBTs are used to implement choppers and inverters. These IGBTs are protected against a variety of severe operating conditions, such as short-circuits, overvoltage, overcurrent, and overheat. The seventh IGBT and an external dumping resistor allow smooth dissipation of excess energy at the DC bus. The dumping circuit can be activated through the use of a toggle switch on the front panel. The module switching control section allows 0/5 V pulse signals from either the Data Acquisition and Control Interface, Model 9063, the Chopper/Inverter Control Unit, Model 9029, or any compatible 0/5 V control unit, to be applied to the gating circuits of the IGBTs. The signals are input in the IGBT Chopper/Inverter module through a 9 pin connector. Six miniature banana jacks are used as test points to monitor the pulse signals using an oscilloscope. These jacks can also be used to inject 0/5 V pulse signals from an alternate control unit, as well as to inhibit each gating circuit. The IGBT Chopper/Inverter module also includes a synchronization output to trigger an oscilloscope when observing the switching control signals as well as a switching control disable input that allows all six IGBTs in the chopper/inverter section to be switched off.

The PC Communication Cable, Model 88362, permits the user to connect the Four-Quadrant Dynamometer, Model 8540, to a computer serial port (or a standard USB-to-Serial converter can be used with it). This will enable the user to monitor and control the Four-Quadrant Dynamometer with the demonstration application included in the model DVD-ROM or any custom application.

2 kW DFIG LABORATORY KIT MODEL 8013-A OPTIONAL EQUIPMENT DESCRIPTION


Model 8134-2 Workstation Model 8321 Inductive Load

The Workstation, Model 8134-2, serves the same purpose as the Mobile Workstation, Model 8110, but it has no storage cabinet nor pull-out work surface. This workstation is intended for use on a bench and is fitted with wooden feet to protect the bench top (not supplied). The Workstation consists of three rows of compartments designed to house EMS modules. Two of these rows have full-height compartments while the other row has half-height compartments. Each row of full-height compartments can accommodate up to three full-size EMS modules or six half-size EMS modules whereas the row of half-height compartments can accommodate up to three half-size EMS modules. The Workstation shares the following features with the Mobile Workstation: a frontmounted release lever and a safety locking device for each compartment and holes in the rear panel of the workstation with removable cover plates. The Workstation requires assembly. A diagram is provided with the workstation to facilitate assembly.

The Inductive Load, Model 8321, is equipped with 9 iron-core power inductors, which have a nominal Q of 10. Each inductor is identified by a schematic symbol, the inductance value, the inductive reactance, as well as the current that will flow through it when connected to a nominal voltage power source. Each inductor is within 5% tolerance of the stated inductance value. Model 8331 Capacitive Load

The Capacitive Load Module, Model 8331, is equipped with 9 oil-filled capacitors. Each capacitor is identified by a schematic symbol, the capacitance value, the capacitive reactance, as well as the current that will flow through it when connected to a nominal voltage power source. Each capacitor is within 5% tolerance of the stated capacitance value. A permanently connected discharge resistor reduces the voltage across each capacitor group to 5% of the applied voltage within 15 seconds after the load is disconnected from the supply.

Model 8840 Enclosure / Power Supply

circuits using a conventional oscilloscope. The output signals can also be used in control circuits as current or voltage feedback signals. The isolated signal at the current output (I) is proportional to the input current. Similarly, the isolated signal at the voltage output (E) is proportional to the input voltage. Both isolators can be used simultaneously. This plug-in module is designed to be inserted into the Enclosure / Power Supply (Model 8840); it is automatically powered when it is inserted into the enclosure. OPAL-RT OP5600 - HIL Simulator Controller & Data Acquisition

The Enclosure / Power Supply, Model 8840, includes a permanently mounted DC power supply that is fully protected against short circuits and overloads. Prewired backplane connectors route power to the individual plug-in control modules. Electric Power is automatically applied to the plug-in control module, when fully inserted into any slot of the Enclosure / Power Supply. Three DC voltages are available from the power supply: +15 V dc, -15 V dc, and +5 V dc. These three voltages are also available at the front panel, terminated by 2-mm banana sockets. A light-emitting diode (LED) indicator for each voltage supply will turn off when the supply goes into an overload condition due to equipment malfunction or faulty power connection to external equipment. Model 9056-B Current/Voltage Isolator

The OP5600 is a complete simulation system comprising a powerful target computer, a flexible high-speed front-end processor, comprehensive digital and analog I/Os and a signal conditioning stage. With its multiple parallel cores, it has the capacity to run, in real time, elaborate Matlab models that can represent a complex physical system, its associated controllers or both. For more information about the specific OPAL-RT optional equipment you need to complete your 2kW DFIG Laboratory, please contact your Lab-Volt Dealer at www.labvolt.com/dealer-locator.

The Lab-Volt Current/Voltage Isolator, Model 9056-B, converts a high-level current and a high-level voltage (AC or DC) into two low-level (0 to 10 V) output signals, electrically isolated from the high-level signal source. This allows observation of the signal waveforms in power
7

2 kW DFIG LABORATORY KIT MODEL 8013-A


OPAL-RT OP8660 - Signal Conditioning Module Interface The OP8660 features high voltage and current probes specifically customized for Lab-Volt's Laboratory Kit power ratings. It can also output the firing pulses to control two IGBT inverter modules and can read two ABZ position encoders. A wide array of digital and (low power) analog I/O are available for the user. Or contact OPAL-RT at www.opal-rt.com/2kWdoubly-fed-induction-generator-kit.

SPECIFICATIONS
Model 8131 Three-Module Workstation Physical Characteristics Dimensions (H x W x D) Net Weight Model 8134-2 Workstation Physical Characteristics Dimensions (H x W x D) Net Weight Model 8311 Resistive Load Resistors Number Resistance (group) Nominal Voltage Accuracy Load at Nominal Voltage (branch) Power Current Number of Steps Current Increment Physical Characteristics Dimensions (H x W x D) Net Weight Model 8321 Inductive Load Inductors Number Inductance (group) Reactance (group) Nominal Voltage Accuracy 12-84 W 0.1-0.7 A Seven of equal increment 0.1 A 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in) 4.5 kg (9.9 lb) 120/208 V 60 Hz 0.8/1.6/3.2 H 300/600/1200 120 V 60 Hz 220/380 V 50 Hz 3.5/7/14 H 220 V 50 Hz 5% 220/380 V 60 Hz 2.92/5.84/11.67 H 220 V 60 Hz 240/415 V 50 Hz 3.8/7.6/15.3 H 1200/2400/4800 240 V 50 Hz Three groups of three inductors 1100/2200/4400 0.05 A 900 x 930 x 530 mm (35.4 x 36.6 x 20.9 in) 50.8 kg (112 lb) 120/208 V 60 Hz 300/600/1200 120 V AC/DC 220/380 V 50 Hz 220/380 V 60 Hz 240/415 V 50 Hz 1200/2400/4800 240 V AC/DC 12-84 W 0.05-0.35 A Three groups of three resistors 1100/2200/4400 220 V AC/DC 5% 11-77 W 375 x 930 x 530 mm (14.8 x 36.6 x 20.9 in) 22.7 kg (50 lb)

Model 8321 Inductive Load (cont'd) Load at Nominal Voltage Reactive Power Current Number of Steps Current Increment Physical Characteristics Dimensions (H x W x D) Net Weight Model 8331 Capacitive Load Capacitors Number Capacitance (group) Reactance (group) Nominal Voltage Accuracy Load at Nominal Voltage Reactive Power Current Number of Steps Current Increment Physical Characteristics Dimensions (H x W x D) Net Weight Model 8374-A0 Line Inductors Inductors (3) Physical Characteristics Dimensions (H x W x D) Net Weight Model 8505-A0 Three-Phase Wound-Rotor Induction Motor Motor (Full Load) Connection Line Voltage Power Speed Current Torque Efficiency Power Factor Friction & Windage Losses Iron Losses Rotor Windings Voltage Current Torque Resistances (per phase at 25 C) Search Coils Stator Rotor Stator Full Pitch Rotor Full Pitch Rotor One Tooth Physical Characteristics Dimensions (H x W x D) Net Weight

120/208 V 60 Hz 12-84 var 0.1-0.7 A

220/380 V 50 Hz

220/380 V 60 Hz 0.05-0.35 A 0.05 A

240/415 V 50 Hz 12-84 var

11-77 var

Seven of equal increment 0.1 A 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in) 10.1 kg (22.3 lb) 120/208 V 60 Hz 2.2/4.4/8.8 F 300/600/1200 120 V 60 Hz 12-84 var 0.1-0.7 A 0.1 A 5.7 kg (12.6 lb) 120/208 V 60 Hz 14 mH 10 A 60 Hz 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in) TBE2 120/208 V 60 Hz 3 ~, wye connected 120/208 V 60 Hz 2 kW 1720 r/min 10.0 A 11.1 Nm (98.2 lbfin) 77 % 0.72 230 W 70 W 624 V Line-to-Line 43 A 12.0 Nm (106.2 lbfin) 0.6 0.7 5 turns 5 turns 5 turns 830 x 400 x 605 mm (32.7 x 15.7 x 23.8 in) 92 kg (202.4 lb) 220/380 V 50 Hz 0.72/1.45/2.89 F 220 V 50 Hz 5% 11-77 var 0.05-0.35 A Seven of equal increment 0.05 A 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in) 12-84 var 220/380 V 60 Hz 0.60/1.21/2.41 F 220 V 60 Hz 240/415 V 50 Hz 0.66/1.33/2.65 F 1200/2400/4800 240 V 50 Hz Three groups of three capacitors 1100/2200/4400

Motor (Starting)

TBE = To be established (Contact your Lab-Volt representative for additional information)

2 kW DFIG LABORATORY KIT MODEL 8013-A


Model 8506-A0 Wiring Module for Wound-Rotor Induction Motor Physical Characteristics Dimensions (H x W x D) Net Weight Model 8525-20 Power Supply Ordering Number3 Input Line Voltage Line Current Service Installation Output Fixed AC, 3 Phases Fixed AC, 1 Phase Variable AC, 3 Phases Variable AC, 1 Phases Convenience Outlet Variable DC Fixed DC Power Cord Length Connector Physical Characteristics Dimensions (H x W x D) Net Weight Model 8540 Four-Quadrant Dynamometer Power Requirements Operation Ranges Speed Range Nominal Torque Range Peak Torque Direction of Rotation HMI Communication Port Braking Resistors Capacity Circuit Breaker Physical Characteristics Dimensions (H x W x D) Net Weight Model 8840 Enclosure / Power Supply Rating Input Power Requirement DC Outputs 212 x 287 x 496 mm (8.3 x 11.3 x 19.5 in) 4.1 kg (9.0 lb) 120/208 V 60 Hz 8525-10 120/208 V 15 A 120/208 V 15 A 120 V 15 A 0 to 120/208 V 15 A 0 to 120 V 15 A 120 V 15 A 0 to 120 V 25 A 120 V 5 A 3 m (10 ft) 120/208 V 15 A, NEMA L21 20 32.6 kg (71.9 lb) 120/208 V 60 Hz 208 V 3 ~ - 12 A 0 to 3600 rpm 0 to 12.18 Nm (0 to 8.98 lbft) 48.72 Nm (35.93 lbft) CW / CCW 228 mm (3.7 in), monochrome, background illuminated, 160 x 64 pixels touch-screen RS-485 (accessible by removing the inverter front panel) 5000 W 15 A 82 x 65 x 36 cm (32.3 x 25.6 x 14.2 in) TBE 120/208 V 60 Hz 120 V 10 % 65 VA +15 V 500 mA -15 V 500 mA +5 V 1 A Physical Characteristics Dimensions (H x W x D) Net Weight Model 8857-10 IGBT Chopper/Inverter DC Bus Maximum Voltage Maximum Current Filtering Capacitor 308 x 287 x 450 mm (12.1 x 11.3 x 17.7 in) 11.1 kg (24.4 lb) 120/208 V 60 Hz 420 V 10 A 1320 F 220/380 V 50 Hz 220 V 10 % 65 VA 240/415 V 50 Hz 240 V 10 % 65 VA 220/380 V 50 Hz 380 V 3 ~ - 6.5 A 0 to 3000 rpm 240/415 V 50 Hz TBE 277/480 V 15 A, NEMA L22 20 220/380 V 50 Hz 8525-15 220/380 V 10 A 220/380 V 10 A 220 V 10 A 0 to 220/380 V 7 A 0 to 220 V 7 A 220 V 10 A 0 to 220 12A 220 V 3 A 240/415 V 50 Hz 8525-1A 240/415 V 10 A 240/415 V 10 A 240 V 10 A 0 to 240/415 V 7 A 0 to 240 V 7 A 240 V 10 A 0 to 240 V 12 A 240 V 3 A

3-phase, 5-wire, Stary (Wye)-connected including neutral and ground

308 x 287 x 500 mm (12.1 x 11.3 x 19.7 in)

Ordering numbers shown are for English versions. Other language are available. Consult your Lab-Volt representative for ordering information.

10

Model 8857-10 IGBT Chopper/Inverter (cont'd) Protections DC Bus Overvoltage DC Bus Circuit Breaker IGBT Electronic Overcurrent IGBT Overheat Dumping Circuit Switching Control Signals Power Requirements Accessories Physical Characteristics Dimensions (H x W x D) Net Weight Model 8895 Three-Phase Splitter Power Requirements Number of outlets Physical Characteristics Dimensions (H x W x D) Net Weight Model 9056-B Current/Voltage Isolator Current Isolator Ranges Maximum Continuous Current Impedances Model 9056-B Current/Voltage Isolator
(cont'd)

120/208 V 60 Hz 440 V 10 A 50 A 70 C approx. 330 V 50 O, 500 W 0/5 V 0-20 kHz 24 V, 0.16 A, 50/60 Hz 24 V power cable (1) 2 mm banana plug test leads (2) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in) 5.1 kg (11.2 lb) 120/208 V 60 Hz 208 V 3 ~ - 20 A 2 110 x 180 x 132 mm (4.3 x 7.1 x 5.2 in) TBE 120/208 V 60 Hz 5/50 A 5/15 A 0.04/0.004 120/208 V 60 Hz 30/300 V 27/280 k 0 to 10 V (isolated from input) <1 k 0 to 15 kHz 600 V 220/380 V 50 Hz 220/380 V 50 Hz 240/415 V 50 Hz 3/30 A 3/8 A 0.07/0.007 240/415 V 50 Hz 60/600 V 58/580 k 220/380 V 50 Hz TBE 240/415 V 50 Hz TBE

Voltage Threshold Level Frequency Range

External Resistor Min. Requirements

Voltage Isolator Output (I and E) Frequency Range (-3 dB) Isolation Accuracy

Ranges Impedances Voltage Impedance

DC to 2 kHz 2 to 5 kHz

1% Full scale 3% Full scale 143 x 63 x 240 mm (5.6 x 2.5 x 9.4 in) 0.8 kg (2 lb) Mitsubishi cable for connection between the Four-Quadrant Dynamometer drive (RJ45 port located behind control panel) and a PC (serial port). Standard USB-to-Serial Converter could be used if no serial port is available.

Physical Characteristics Dimensions (H x W x D) Net Weight Model 88362 PC Communication Cable Description

11

Reflecting Lab-Volt's commitment to high quality standards in product, design, development, production, installation, and service, our manufacturing and distribution facility has received the ISO 9001 certification. Lab-Volt reserves the right to make product improvements at any time and without notice and is not responsible for typographical errors. Lab-Volt recognizes all product names used herein as trademarks or registered trademarks of their respective holders. Lab-Volt 2013. All rights reserved. 89439-00 Rev. A