Beruflich Dokumente
Kultur Dokumente
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
6F-17
Ordering Information:
To Order:
Style A EJB684
Style B1 EJB886
Style B2 EJB4164
Style C
Styles A, B1, B2
Cat. #
4
6
6
8
8
4
8
9
12
12
6
8
8
8
12
16
10
16
16
23
4
4
6
6
4
4
6
6
8
6
A
A
A
B1
B1
B2
B1
B1
B1
B1
4
6
6
8
8
8
12
6
8
8
8
12
10
16
4
4
6
6
4
6
8
A
A
A
B1
B1
B1
B1
Aluminum
EJB464-SA
EJB684-SA
EJB686-SA
EJB886-SA
EJB1284-SA
EJB8106-SA
EJB12168-SA
Cat. #
EJB121204
EJB121206
EJB121208
EJB161606
EJB161608
EJB181206
EJB181208
EJB241208
EJB241210
EJB241808
EJB241810
EJB242408
EJB242410
EJB361208
EJB361808
EJB361810
EJB362408
Nominal Inside
Dimensions
Top &
Sides Bottom
(aa)
(bb)
12
12
12
12
12
12
16
16
16
16
12
18
12
18
12
24
12
24
18
24
18
24
24
24
24
24
12
36
18
36
18
36
24
36
Step 1
Select the box required from photos at left,
listings, and dimensional drawings on pages
6F-18 to 6F-20.
Step 2
Select standard conduit arrangement from
Table 1 and maximum size conduit opening
required from Table 2.
Step 3
Select appropriate symbol for required drilled
and tapped opening from Table 3.
Example:
Step 1 Box required EJB886
Step 2 Arrangement 2
Step 3 Openings two 1N drilled and tapped
holes in top and bottom and two 2N drilled
and tapped holes on each side.
Step 4 Symbols are substituted and written
in clockwise order starting with a. When no
opening is required at a particular location,
use symbol 0 (zero).
For this example: CC,GG,CC,GG. Complete
Cat. No. is made up of three parts: Part 1
box number; Part 2 arrangement number;
Part 3 symbols for conduit openings. For
this example:
EJB886-2-CC-GG-CC-GG
If none of the standard arrangements meet
requirements, send a sketch showing
junction box number with size and location of
each conduit opening desired.
Depth
4
6
8
6
8
6
8
8
10
8
10
8
10
8
8
10
8
PDFINFO
CH0 6 F - 1 7
April 1999
6F-16
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Application:
Features:
ALL STYLES:
1 Stainless steel cover bolts.
1 Ground joint cover opening provides
maximum opening for pulling wires or
mounting equipment.
1 Walls of selected bodies may be drilled and
tapped for conduit entries as shown in
listings.
1 Stud bolts in diagonally opposite corners of
body aid in aligning cover to body during
installation (not furnished with hinged
covers).
EJB STYLE C:
1 All Style C bodies are provided with captive,
quick release hex head stainless steel bolts
with spring loaded action which provides
clear indication that cover bolts are fully
retracted from the body.
1 External flange design wide unobstructed
cover opening provides a completely
accessible interior for wiring and electrical
equipment.
1 Square corners of enclosure body provide
maximum interior space and area for conduit
openings.
1 Flat cover provides additional space for
mounting a greater number of control
devices.
1 Internal grounding lug provides a means to
ground enclosed equipment.
1 Special neoprene cover gasket provides a
watertight seal to meet NEMA 4
requirements, and provides superior
protection for enclosed equipment against
water/corrosion.
1 Enclosures are machined for field installed
mounting plates.
1 Detachable mounting feet provide
mounting flexibility. No need to replace
enclosure if mounting feet are broken.
1 Optional aluminum hinges provide
convenient and easy access for inspection,
maintenance and systems changes.
1 Enclosures are machined to accept field
installed hinges.
NOTE: For conduit liner ordering information, see page 6F-29.
January 1996
PDFINFO
CH0 6 F - 1 6
Standard Materials:
Standard Finishes:
Certifications and
Compliances:
1 NEC/CEC:
Class I, Division 1 & 2, Groups C,D (Styles
A, B1, B2, and EJB602212 except EJB8106
and EJB12236 Group D only)
Class I, Division 1 & 2, Groups B, C D
(Style C only)
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
1 UL Standard: 886/CSA Standard: C22.2 No.
30
1 UL Raintight/CSA Raintight
1 NEMA/EEMAC 3, 4 (Style C only), 7BCD,
9EFG
Options
Suffix to be
Description
added to Cat. No.
Hinged covers. Hinges mounted on
left (short side) unless otherwise
specified . . . . . . . . . . . . . . . . . . . . . . . . . . . S598
Hinge kits for field installation (no field
machining required for Style C enclosures)
EJB121204 through 181208. . . . . . . . EJB KIT 1
(2 hinges)
EJB241208 through 361208 . . . . . . . EJB KIT 2
(2 hinges)
EJB361808 through 361810 . . . . . . . EJB KIT 3
(3 hinges)
EJB362408 . . . . . . . . . . . . . . . . . . . . . EJB KIT 4
(4 hinges)
Factory installed mounting plates for relays,
terminal blocks, electrical devices, etc.
Aluminum . . . . . . . . . . . . . . . . . . . . . . . . . . MP
Phenolic insulated . . . . . . . . . . . . . . . . . MPB
Mounting plate kit for field installation (kit
includes aluminum mounting plate, pillars
and mounting hardware.
No field machining required for
Style C enclosures) . . . . . . . . . . . See Ordering
Information on page 6F-18
Factory installed terminal
blocks . . . . . . . . . . . . . . Information on request
6F-18
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Ordering Information
Dimensions Pg. 6F-20
Table 1/Conduit Arrangement Diagrams
Spacing Dimensions
4
2
2
2
214
178
178
112
234
4
214
314
314
6
Styles A, B1 and B2 Drilled and Tapped Openings Feraloy Iron Alloy or Aluminum
Group D Locations Only
EJB464
EJB684
EJB686
EJB886
EJB1284
EJB4164
EJB8106
EJB9166
EJB12168
EJB12236
2
2
2
312
112
2
2
2
4
2
112
2
2
2
112
2
2
2
4
2
1
114
114
1
112
2
112
2
3
2
34
34
12
112
2
1
2
2
2
2
2
2
312
112
2
2
2
4
2
1
112
112
2
112
34
2
2
312
2
34
34
1
1
12
1
114
2
2
34
34
1
114
114
214
214
338
338
214
214
338
338
434
338
138
2
2
134
3
6
234
514
4
8
1
112
112
134
2
78
178
2
3
3
2
212
212
2
3
6
3
514
5
8
238
234
314
314
112
134
134
2
234
212
April 1999
PDFINFO
CH0 6 F - 1 8
6F-19
Ordering Information
Dimensions Pg. 6F-20
Cat. #
EJB121204
EJB121206
EJB121208
EJB161606
EJB161608
EJB181206
EJB181208
EJB241208
EJB241210
EJB241808
EJB241810
EJB242408
EJB242410
EJB361208
EJB361808
EJB361810
EJB362408
312
5
312
5
312
5
5
6
5
6
5
6
5
5
6
5
112
312
312
312
5
312
5
5
6
5
6
5
6
5
5
6
5
112
112
34
12
112
112
212
3
312
312
5
5
5
5
5
5
5
5
5
5
112
112
2
2
212
212
312
312
312
312
312
312
5
5
5
5
1
1
1
112
112
112
2
3
3
3
3
3
3
4
4
4
4
34
114
114
112
112
212
212
212
212
212
212
4
4
4
4
12
34
Sides (aa)
1
2
112
112
114
34
12
34
12
34
34
1
1
112
112
1
1
112
1
1
1
1
2
2
2
2
2
2
312
312
312
312
34
34
34
1
112
112
112
112
112
112
212
212
212
212
312
5
312
5
312
5
5
6
5
6
5
6
5
5
6
5
312
312
312
5
312
312
312
312
5
6
5
6
312
5
6
5
112
112
212
3
112
112
112
112
312
312
5
5
112
312
312
5
114
114
2
2
114
114
114
114
212
212
312
312
114
212
212
312
1
1
1
112
112
1
1
1
1
2
2
3
3
1
2
2
3
114
114
34
34
1
1
112
112
212
212
34
112
112
212
12
112
34
12
1
1
12
12
12
12
114
114
2
2
12
114
114
2
Spacing Dimensions
Cat. #
L2
S2
L3
S3
L4
S4
L5
S5
L6
S6
L7
S7
L8
S8
EJB121204
EJB121206
EJB121208
EJB161606
EJB161608
EJB181206
EJB181208
EJB241208
EJB241210
EJB241808
EJB241810
EJB242408
EJB242410
EJB361208
EJB361808
EJB361810
EJB362408
3
334
434
334
434
334
434
518
618
514
614
538
638
434
512
612
6
214
3
3
3
314
3
4316
4316
434
4316
434
4316
434
4716
4716
434
434
214
3
3
3
314
3
3
3
3
4316
434
4316
434
3
4716
434
4316
358
358
358
458
6
6
6
8716
8716
8716
8716
8716
8716
8716
8716
8716
8716
358
358
358
458
458
358
358
358
358
6
6
8716
8716
358
6
6
8716
3116
3116
3116
4316
4316
458
458
6
6
6
6
6
6
8716
8716
8716
8716
3116
3116
3116
4316
4316
3116
3116
3116
3116
458
458
6
6
3116
458
458
6
2
2
2
234
234
234
314
458
458
458
458
458
458
534
534
534
534
2
2
2
234
234
2
2
2
2
314
314
458
458
2
314
314
458
134
134
134
212
212
234
234
378
378
378
378
378
378
534
534
534
534
134
134
134
212
212
134
134
2
2
234
234
378
378
134
234
234
378
112
112
112
2
2
2
2
314
314
314
314
314
314
518
518
518
518
112
112
112
2
2
112
112
112
112
212
212
314
314
112
212
212
314
134
134
134
2
234
234
234
234
234
234
378
378
378
378
134
134
2
2
234
234
2
2
234
NOTE: Conduit seals are required in all conduit entrances for Class I,
Division 1, Group B hazardous areas, and for EJB361208, EJB361808,
EJB361810 and EJB362408 enclosures when used in Class I, Division
1, Group C hazardous areas. For other sealing requirements, consult
the National Electrical Code. Where standard arrangements are not
adequate, special drilling and tapping can be ordered, or instructions
can be provided for field drilling and tapping. Breathers and drains
must be ordered separately see page 8F-10.
Drilled and tapped openings for vertical mounted enclosures with horizontal conduit entries
consult Crouse-Hinds for proper pouring space for seals.
PDFINFO
CH0 6 F - 1 9
April 1999
6F-21
Styles A, B1, B2
Style C
Styles A, B1, B2
Cat. #
EJB-MP46
EJB-MP68
EJB-MP88
EJB-MP128
EJB-MP416
EJB-MP810
EJB-MP916
EJB-MP1216
EJB-MP1223
5
7
6
11
14
9
13
14
20
3
5
6
6
3
7
6
8
8
.094
.094
.094
.094
.094
.094
.094
.094
.125
414
614
5
8
13
814
12
13
19
214
414
5
5
2
614
5
7
7
12
7
10
4
4
Cat. #
EJB-MP1212
EJB-MP1616
EJB-MP1812
EJB-MP2412
EJB-MP2418
EJB-MP2424
EJB-MP3612
EJB-MP3618
EJB-MP3624
11
15
17
23
22
22
34
3312
34
11
15
11
11
16
16
10
1512
22
.125
.125
.125
.125
.125
.125
.125
.125
.125
9
13
13
19
19
19
31
31
31
9
13
7
7
13
19
7
13
19
512
512
8
11
5
734
11
138
138
238
238
178
178
178
158
178
112
112
212
212
2
2
2
134
2
1
1
2
2
112
112
112
114
112
Style C
812
1112
11
11
17
1634
17
PDFINFO
CH0 6 F - 2 1
April 1999
6F-20
Dimensions
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Mtg.
Hole
516
1332
1332
Diagram
A
and
D
aa
514
714
714
bb
714
914
914
912
15316
1834
1158
17
1712
2434
916
B
and
D
912
11316
634
958
10
1358
1314
17116
17116
17116
21316
21316
17516
17516
17916
17916
23916
23916
29916
29916
17116
231516
231516
30316
17116
17116
17116
21316
21316
23516
23516
29916
29916
2958
2958
29916
29916
41116
411516
411516
42316
916
C
and
E
1332
916
1332
916
916
916
916
916
916
916
916
916
916
916
1116
1116
1116
1116
916
1116
1116
1116
vv I
858
11116
11116
ww
xx
512
578
778
yy
778
10116
10116
zz
414
51316
51316
10
934
18
778
1312
1612
2412
1258
11116
834
11916
1338
17
1714
8916
618
5916
778
9316
1218
10
8
838
16
638
1112
1412
2212
1138
10516
712
10516
1218
1534
16
82
67
68
74
140
230
220
1618
1618
1618
2018
2018
1618
1618
1618
1618
2312
2312
2912
2912
1618
2312
2312
3114
61316
878
1078
878
1078
878
1078
1134
1334
1214
1414
12516
14516
111116
12716
1438
1258
512
512
512
912
912
1112
1112
1712
1712
1714
1714
1614
1614
2912
2814
2814
2814
1518
1518
1518
1918
1918
1518
1518
1558
1558
2178
2178
2778
2778
1518
2178
2178
2912
Dimensions for EJB684 through EJB12236 Feraloy boxes also apply to EJB686-SA through EJB12236-SA aluminum boxes.
I Mounting strap location varies with body. In some cases, they extend beyond the sides.
* See Certifications and Compliances on page 6F-16.
PDFINFO
CH0 6 F - 2 0
31
25
28
87
60
70
80
103
113
101
110
149
160
243
258
296
322
185
351
396
571