D-198.1-AM6000N-ENG Rev. A.

3 06/2011 ANALOGUE CONTROL PANEL

AM6000

DESCRIPTION
AM6000 is a microprocessor based intelligent fire detection panel compatible with all Notifier analog loop devices. Panel is designed to comply with EN-54.2 and EN54.4.standards as well the European directive for CE marking. The base version, is equipped with 4 analogue communication loops, but it is possible to expand the number of loops up to 16 by using 3 LIB600N boards, providing 4 additional loops each. AM6000 can be programmed by dedicated software (PK6000), that allow configuration saving and printing. Available, on request, with MODBUS protocol.

MAIN FEATURES

Microprocessor based system. 4 analogue communication loops in the base version. Expansible with max. 3 additional board providing 4 loops each, for a total of 16 loops. 99 detectors + 99 input/output modules for each line. Base version 19 9 standard unit. Graphic backlit LCD display 16 lines, 40 columns (480X128 dots). 2 serial interfaces in standard version: - 1 interface RS-485 to connect up to 24 repeater LCD6000N/T and LCD6000A; - 1 interface RS-232 to connect a PC with PK6000 tool 4 access levels designed in according to EN-54.2 and EN.54.4. standards. 3 passwords levels (Operator - Maintenance Configuration). Configurable words: point description with 32 characters; 32 characters zone description. 150 physical zones and 400 logic groups. User-programmable Control-by-event (CBE) equations to program actions to be performed, using logic operators (And-Or-Xor-Delay-etc.). History log 999 events in non volatile memory. Real time watch. Self- loop configuration with self device recognition. Default software function configuration for in field devices. Auto-recognition points with same address. Alarm and fault management. Alarm threshold detectors programmable. Detector cleaning required signalling. Low sensitivity detector signalling. Automatic night/day sensibility commutation. Walk-Test function for each zone. Keyboard with specific function key: evacuation, reset delay, buzzer silence, silence/restore sounder, reset Alphanumeric keys for in field configuration.

OUTPUTS Supervisioned sounders output. 2 Free voltage contacts relay output:


- general alarm; - general fault.

POWER SUPPLY
Control panel is powered from mains and in mains fault condition it will continue normal operating, regarding rechargeable batteries fitted inside. Mains requirements are follows: Voltage: 230 Vac single-phase -15% +10%. Frequency: 50 / 60Hz. Current: 0.75 A. Power supply 27.6Vcc (27.6Vdc -10% +2% ripple max. 100mVpp) 4A tot, (power for panel, user output, power supply for analogue device on loop). User output for auxiliary loads; in example: bells sounders, etc. Battery charger: - Output voltage: 27,6Vdc - Output current: 1.5A - ripple max 100m Vpp (with temperature compensation) - Batteries: 2 x 24 Ah max. - Signalling: Low batteries, unbalanced charging, batteries fault.

ENVIRONMENTAL FEATURES Temperature range: - 5 C + 40 C. Humidity: 10 93 % (without condensate). Stock temperature: - 10 C + 50 C. MECHANICAL FEATURES Weight: 10.150 Kg. Dimensions: 535 x 435 x 200 mm. IP grade: 30.

D-198.1-AM6000N-ENG Rev. A.3 06/2011 ANALOGUE CONTROL PANEL

AM6000

PK6000 PK Software

LCD PANELS REPEATER

Remote panels with LCD display for NOTIFIER The software allows to transfer and display on PC panel Series AM remote panel management. configurations; it is also possible to prepare with PC all All repeaters are endowed with a backlit graphic panel configurations and transfer them into the panels. LCD display 320x240 dots. Repeaters are characterized with optimal brightness and high contrast that assure clear sight in any environment light conditions. The connection with panels is performed by RS-485 port. All repeaters are compliant to the EU directive for CE marking.

LCD-6000-N Fire repeater.


LCD-6000-N is endowed with seven keys that allow navigation through different menus displayed and execution of system management function: silent, reset, disablement and lamp test. The programming functions that can be realized by using this software are the same the user can carry out working on the control panel. PK software is compatible with all Windows versions. The communication between control panel and PC is realized through RS232 serial port.

LCD-6000-A Zone programmable repeater.


LCD-6000-A show active panel events, relating devices or zones. The zone displayed are configured by PC with PK software.

OPTIONAL BOARDS
SIB600W: Microprocessor-based communication board for new concentration system. SIB600W is equipped of 1 Ethernet port (LAN TCP/IP), 1 USB port for PC and printer. SIB600W is linkable with all compatible external devices. SIB600OEM: Serial interface communication board. SIB600OEM is endowed with an RS232/485 output for connection to NOTI-FIRE-NET-2000N with CEIABI protocol (only for fire system). LIB600: LIB600 provide 4 analog lines, programmable as style 4 or 6 (Open or close loop). The capacity for each loop is 99 detectors and 99 modules for an amount of 3168 devices with 16 loop configuration. Those applications must be accomplished in accordance with EN54 rules; however its necessary bear in mind the limit of 512 devices for each LIB (4 loops), for an amount of 2048 devices).

LCD-6000-T Technologic alarm repeater and Gas detection.


Specific to display events relating gas detection and 420mA technologic events. LCD-6000-T is equipped with 3 additional LEDs for pre-alarm and alarm levels.

NOTIFIER ITALIA S.r.l. - A socio unico - 20097 San Donato Milanese (Ml) - Via Grandi, 22 - Tel.: 02/518971 - Fax: 02/5189730 - E-mail: notifier@notifier.it Capitale Sociale 2.700.000,00 i.v. - C.C.A.A. 1456164 - Trib. Milano Reg. Soc. 348608 - Vol. 8549 Fasc. 8 - Partita IVA IT 11319700156 (informativa privacy art. 3 Digs 196/03) - Ufficl Regionali: 10143 Torino Corso Potenza, 6 - Tel.: 011/0650611 - Fax: 011/4531183 E-mail: notifier.torino@notifier.it - 35010 Limena (PD) Via IV Novembre, 6/c Int. 9 - Tel.: 049/7663511 - Fax: 049/7663550 - E-mail: notifier.padova@notifier.it - 40050 Funo di Argelato (BO) - Asta Servizi, Bl. 3B, Gall. B n. 85, Centergross - Tel.: 051/864855 - Fax: 051/6647638 - E-mail: notifier.bologna@notifier.it - 50136 Firenze Via Aretina, 167/M Tel/Fax: 055/289177 - 00118 Roma - Via Del Casale Santarelli, 51 - Tel.: 06/7988021 Fax: 06/79880250 - E-mail: notifier.roma@notifier.it - 80143 Napoli - Palazzo Prof. Studi - Centro Direzionale, Isola E2, Scala B, Piano 5 - Tel.: 081/7879398 - Fax: 081/7879159- E-mail: notifier.napoli@notifier.it - 70125 Bari - Via Delia Costituente, 29 - Tel.: 080/5013247 - Fax: 080/5648114 - E-mail: notifier.bari@notifier.it - 95128 Catania - Viale Alcide De Gasperi, 187 - Tel.: 095/7128993 - Fax: 095/7120753 - E-mail: notifier.catania@notifier.it www.notifier.it Tutti i dati sono soggetti a cambiamento senza preavviso. Tutti i diritti di questa pubblicazione sono riservati.