Beruflich Dokumente
Kultur Dokumente
SHEET INDEX Title Sheet Soil Nail Facing Rock/Shotcrete Facing Manta Ray Anchor Wall H-Pile Wall Facing Sheet Pile Wall Facing
Railing per Site Plans 7.5' 6.5' Top of concrete wall
Thickness varies at steps and landings Bond Breaker/Exp Jt Keystone Compac Units
Sheet 8
Select Backfill Existing Concrete Wall SG200 Geogrid Wrap Pipe and Return
Finished Grade
Finished Grade
Leveling Pad Leveling pad at elevations and stations per layout plans
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc. The information contained herein has been compiled by Keystone Retaining Wall Systems and to the best of our knowledge, accurately represents the Keystone product use in the applications which are illustrated. This drawing is being furnished for design guidance and estimating only. Final determination of the suitability for the use contemplated and its manner of use are the sole responsibility of the user. Structural and geotechnical design analysis shall be performed by a qualified engineer. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of Keystone Retaining Wall Systems, Inc. No. Date Revision By Designed By: cdm Checked By:
Specialty Applications
Scale: Project No:
Title Sheet
Drawing No.
Date: 1/10/00
#4 Rebar
Geogrid
Drainage Net
Shotcrete
Flowable Concrete Fill #4 Rebar #10 bar-Extended Threads #10 Grade 60 Anchor (2) - Nuts to Secure Plate 6" x 6" x 1/2" Steel Plate
Keystone Compac Units Horizontal #4 Rebar @ 2.5' c/c (at anchor locations) Geogrid Soil Anchors 5' c/c Vertical #4 Rebar @ 2.5' c/c Flowable Concrete Fill f'c = 500 psi - 2' Lifts 1 8 5' Typ. Finished Grade Geogrid - 2' Vertical c/c Extend to Shotcrete Between rebar Finished Grade
Temporary Shotcrete & Mesh Facing Support System with Drainage. (design by others)
#57 Stone Wrapped in Geotextile Footing Steps Leveling Pad at Elevations and Stations per Layout Plans 6" Perforated PVC Collector Pipe to Underdrain System
Date: 1/10/00
#5 Rebar
Rock
4" x 4" x 1/4" Steel Plate with (2) - Nuts to Secure Plate
Protect Exposed Anchor from Corrosion. (galvanize, cold tar epoxy, grouted sleeve)
Keystone Standard Unit with Tail Cutoff Keystone Standard Unit Keystone Standard Unit with Tail Cutoff Keystone Standard Units Unit Drainage Fill
Rock Bolt or Rock Anchor (length and spacing determined by design engineer)
Concrete Beam (min 2" into unit above and below , f'c -4000 psi) (4) - #5 Rebar
Keystone Standard Units See Concrete Beam Detail Keystone Standard Unit with Tail Cutoff
Rock
Unit Drainage Fill Footing Steps Leveling Pad at Elevations and Stations per Layout Plans 6" Perforated PVC Collector Pipe
Rock/Shotcrete Facing
Drawing No.
Date: 1/10/00
Unit Drainage Fill Geogrid (LTDS >1200 plf) Keystone Compac Unit Unit Drainage Fill Geogrid Stiff Firm Soil 6' c/c 3" Galvanized Pipe Manta Ray Anchors Galvanized Pipe Loop Connector 3/4" Galv. CTB Rod Manta Ray Anchor 3" Galvanized Pipe, Sch 40 Galvanized Pipe Loop Connector
Stiff Firm Soil 5 3" Galvanized Pipe Keystone Compac Units Soil Failure Plane Galvanized Pipe, Loop Connector and Manta Ray Anchors (staggered installation) 1 8
Finished Grade
Finished Grade
Footing Steps
Date: 1/10/00
Unit Drainage Fill Geogrid 3" Galvanized Pipe Welded Pipe Loops Steel H Piles 6' to 8' c/c 3" Galvanized Pipe Keystone Compac Unit Welded Pipe Loop #6 Rebar or 1/4" x 1.5" Bar Stock Steel H Piling Keystone Compac Units Unit Drainage Fill Timber Lagging as Req'd Timber Lagging Geogrid (LTDS >1200 plf)
1 32
Unit Drainage Fill Leveling pad at elevations and stations per layout plans 4" Perforated PVC Collector Pipe
Date: 1/10/00
Unit Drainage Fill Geogrid 3" Galvanized Pipe Welded Pipe Loops Sheet Piling 6' to 8' c/c 3" Galvanized Pipe Keystone Compac Unit Welded Pipe Loop #6 Rebar or 1/4" x 1.5" Bar Stock Steel Sheet Piling Keystone Compac Units Geogrid
Keystone Compac Units Steel Sheet Piling PZ22/PZ27 Typical (design by others) 1 32 3" Galvanized Pipe & Welded Pipe Loop
Unit Drainage Fill Leveling Pad at Elevations and Stations per Layout Plans 4" Perforated PVC Collector Pipe
Date: 1/10/00
Existing Concrete Wall 3" Galvanized Pipe #6 Pipe Anchors 6' c/c 3" Galvanized Pipe (use threaded couplers) 7.5' Top of Wall 8.2' Bottom of Wall for 1:32 Batter
Hilti HVA Epoxy Adhesive System (1" hole for #6 rebar) 5"-6"
5"-6" #6 Rebar Pipe Anchors Bend as shown. Install per epoxy manufacturer. Coat with cold tar epoxy after installation. 6 5/8"
Top of existing concrete wall Railing per Site Plans 10 @ 7 1/2" = 6.25' Key Pipe Anchors/Pipe Stratagrid SG200 Cut Blocks 10 @ 7 1/2" = 6.25' Thickness varies at steps and landings Bond Breaker/Exp Jt Keystone Compac Units
7.5' 6.5'
Select Backfill Existing Concrete Wall Geogrid Wrap Pipe and Return
10 @ 7 1/2" = 6.25'
Finished Grade
Leveling Pad
Date: 1/10/00
Typical Detail
P L 5' Cap Unit Keystone Standard Units Limits of excavation Unit Drainage Fill Low Permeable Soil
1 8
Specialty Applications
Scale:
Date: 1/10/00
Wing Wall
Barrier Parapet Top of Wall Wing Wall Top of Sidewalk Profile Keystone Cap Unit Keystone Compac Unit Geogrid Geogrid Geogrid Geogrid
Geofoam
Roadway Geogrid
Gravel Borrow 12" Concrete Slab
Geogrid
1/2"! pins
Geofoam
Geofoam
Bottom of Wall
Footing Step
Bottom of Geofoam
Typical Section
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc. The information contained herein has been compiled by Keystone Retaining Wall Systems and to the best of our knowledge, accurately represents the Keystone product use in the applications which are illustrated. This drawing is being furnished for design guidance and estimating only. Final determination of the suitability for the use contemplated and its manner of use are the sole responsibility of the user. Structural and geotechnical design analysis shall be performed by a qualified engineer. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of Keystone Retaining Wall Systems, Inc. No. Date Revision By Designed By: cdm Checked By:
Specialty Applications
Scale:
Keystone/Geofoam Wall
Project No: Drawing No.
Date: 1/10/00
5' Dia 1
Concrete Pier
Foundation Obstruction
Drawing No.
Date: 1/10/00
10
Even Course
Cut in Half
12"
18"
Compac Unit
Front Elevation
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc. The information contained herein has been compiled by Keystone Retaining Wall Systems and to the best of our knowledge, accurately represents the Keystone product use in the applications which are illustrated. This drawing is being furnished for design guidance and estimating only. Final determination of the suitability for the use contemplated and its manner of use are the sole responsibility of the user. Structural and geotechnical design analysis shall be performed by a qualified engineer. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of Keystone Retaining Wall Systems, Inc. No. Date Revision By Designed By: cdm Checked By:
Specialty Applications
Scale: Project No:
Date: 1/10/00
11
Even Course
Odd Course
Three Unit Assembly - Grouted with #3 bars
Plan View
Installation 1. Cut out wall in 3-4 unit segments. 2. Drive anchor into backfill and lock. 3. Install three unit slip joint segment. 4. Repeat as required.
8"
11" Cut Off 9.5" 1" Hole for threadbar MR-88 Manta Ray Drive Anchor and 6' Threadbar
12"
18"
3 Unit Assembly
COPYRIGHT (c) 2000 by Keystone Retaining Wall Systems, Inc. The information contained herein has been compiled by Keystone Retaining Wall Systems and to the best of our knowledge, accurately represents the Keystone product use in the applications which are illustrated. This drawing is being furnished for design guidance and estimating only. Final determination of the suitability for the use contemplated and its manner of use are the sole responsibility of the user. Structural and geotechnical design analysis shall be performed by a qualified engineer. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of Keystone Retaining Wall Systems, Inc. No. Date Revision By Designed By: cdm Checked By:
Specialty Applications
Scale: Project No:
Date: 1/10/00
12