Sie sind auf Seite 1von 264

50/60 Hz

e-SV Series
1, 3, 5, 10, 15, 22
33, 46, 66, 92, 125
SPECIAL VERSIONS

ErP 2009/125/EC (50 Hz)

Cod. 191002041 R
ev
.E Ed.01/2013
Rev
ev.E

CONTENTS

INTRODUCTION

ErP 2009/125/EC (50 Hz)

HIGH PRES
SURE (50/60 Hz)
PRESSURE
Water treatment industry - washing and cleaning
- Versatile range
- Long lasting performances
- Easy installation and maintenance

15

LOW NPSH (50/60 Hz)


ErP 2009/125/EC (50 Hz)
Solving cavitation issues in installation
- Consistent operation
- Long lasting performances
- Easy installation

65

HIGH TEMPERA
TURE (50/60 Hz)
TEMPERATURE
ErP 2009/125/EC (50 Hz)
Electric pumps for high temperature applications
- H versions for temperature values up to 150C
- B BOILERversions for temperature values up to 180C

107

e-SVH - e-SVTM WITH HYDRO


VARTM (50 Hz)
HYDROV
ErP 2009/125/EC (50 Hz)
An evolution of e-SVTM special version
toward a variable speed intelligent system

123
10

Q [US gpm]

100

80

4-POLE VERSION (50/60 Hz)


Silencious operation
- Low level of noise
- Wide range of performances
- Increased performance with HYDROVARTM

H [ft]

H [m]

250
70

200

60

50
150
40

100

92SV

66SV

125SV

46SV

33SV

22SV

15SV

5SV

10SV

3SV

20

1SV

30

50

10

157

CONTENTS

REDUCING FOOTPRINT (50/60 Hz)


ErP 2009/125/EC (50 Hz)
Space saving in installation
- Compact design
- Versatile design
- High level performances

211

HORIZONT
AL INST
ALLA
TION (50/60 Hz)
HORIZONTAL
INSTALLA
ALLATION
ErP 2009/125/EC (50 Hz)
Installation in reduced vertical space
- Reduced vertical space
- Easy installation

215

MOTORS (50/60 Hz)


ErP 2009/125/EC (50 Hz)
- High efficiency
- Wide range of voltages
- Wide range of options

221

PROTECTION SENSOR AGAINST DRY RUNNING


Pump dry-running detection device

i-ALERT - CONDITIONAL MONITORING


Vibration monitoring device for preventing
irregular operating conditions

233
237

REPORTS AND DECLARA


TIONS
DECLARATIONS
List of main documents (test reports, declarations,
certificates) available for e-SVTM

241

CONTENTS

ACCES
SORIES
ACCESSORIES
Wide range of accessories for installation

243

TECHNICAL APPENDIX

255

Lowara is a registered trademark of Lowara srl Unipersonale, a company controlled by Xylem Inc.
e-SV is a registered trademark of Fluid Handling LLC, a company controlled by Xylem Inc.
HYDROVAR is a registered trademark of Fluid Handling LLC, a company controlled by Xylem Inc.
i-ALERT is a registered trademark of ITT Corporation.
Victaulic is a registered trademark of Victaulic Company Ltd.

INTRODUCT
ION
INTRODUCTION

INTRODUCTION

INTRODUCT
ION
INTRODUCTION

e-SV SERIES - SPECIAL VERSIONS

Introduction
Our customers are central to our business.
Many years of collaboration with them across the different
markets and all over the world has taught us that
specifically designed pumps are required to handle special
applications or to fulfill particular installations. It is essential
to ensure top performance of the systems and continuous
quality of the production.
Therefore Lowara has developed a wide range of special
versions of its vertical multistage e-SV TM to give an
appropriate and dedicated solution to special applications
and installations in the industry or in the building services
market.

Pump design
Non-self priming, vertical multistage, high pressure
centrifugal pump, with suction inlet and outlet of the same
identical nominal diameters, coupled to a standard motor.
Horizontal installation also available, see specific section.

Drive

Special versions and options index

Without speed control: Short circuit squirrel cage


motor, totally enclosed, fan-cooled (TEFC), three-phase,
2 and 4 poles, efficiency class IE2 or IE3 from 0,75 kW
up (IEC 60034-30).
Single-phase version up to 2,2 kW (built-in automatically
resettable overload protection up to 1,5 kW).

The first part of this booklet will cover the following special
versions:
- High Pressure
- Low NPSH
- High Temperature (150C)
- High Temperature (180C)
- With HYDROVARTM (SVH)
- 4-pole version
- Reducing footprint
- Horizontal Installation

With HYDRO
VARTM speed control system
HYDROV
system: A special
version of e-SVTM which becomes an intelligent, variable
speed system. Ideal for single pumping solution or multiple
pumping set solution (up to 8 pumps). See specific section
of (e-SVH HYDROVARTM fitted).

The second part of this booklet will cover the following


sections:
- Motors configuration and standard options
- Protection sensor against dry running
- i-ALERTTM device
- Reports and declarations
- Accessories

Consult the specific section for further motor options.

Documentation and support


Pump selection software, visit:
http://www.xylect.com
Documentation is also available on:
http://www.lowara.com
Visit us for information including video, commercial
leaflet, brochure, other technical catalogues, 2D and 3D
drawings, IOM.

COMP
ATIBILITY MA
TRIX
COMPA
MATRIX
TM
The following table describes the
- recommended compatibility between the special versions of e-SV .

SPECIAL VERSIONS

Low
NPSH

Low NPSH
High pressure
High Temperature 150 or 180C
Version with HYDROVARTM
Reducing footprint "R"
Horizontal Installation
4-Pole

= Available.

U= su richiesta.

High

High Temperature Version with

pressure

150 or 180C

N/A

N/A

N/A

N/A

N/A

N/A

TM

HYDROVAR

Reducing

Horizontal

footprint "R"

Installation

Pole

N/A

N/A

N/A

N/A

U
U

N/A= not available.

sv-spec-en_c_tc

As a global supplier, Lowara can design specific solutions according to the requirements of the application or of the
installation. For example, Lowaras custom-built solutions can handle more aggressive liquids or heavy duty applications.
For more information, refer to the Lowara sales network.

ErP 2009/125/EC
e-SV SERIES
PUMPS
With the Energy using Products (EuP 2005/32/EC) and Energy related Products (ErP 2009/125/EC) directives,
the European Commission has established requirements for promoting the use of products with low power
consumption.
Among the various products considered there are also some typologies of pumps with the characteristics defined
by the specific Regulation (EU) n. 547/2012 implementing the requirements of Directives EuP and ErP.
For vertical multi-stage pumps (MS-V for the Regulations), the efficiency evaluation refers to:

just the pump and not the pump and motor assembly (electric or combustion);
pumps with a nominal pressure PN not higher than 25 bar (2500 kPa);
pumps designed to operate at a speed of 2900 min-1 (for electric pumps this means 50 Hz 2-pole electric
motors);

pumps with a maximum flow of 100 m3/h;


use with clean water at a temperature ranging from -10C to 120C (the test is performed with cold water at a
temperature not higher than 40C).
The Regulation also establishes the following deadlines:
from

minimum efficiency index (MEI)

1st January 2013

MEI 0,1

1st January 2015

MEI 0,4

INTRODUCT
ION
INTRODUCTION

e-SV SERIES - SPECIAL VERSIONS

INTRODUCT
ION
INTRODUCTION

ErP 2009/125/EC
e-SV SERIES
PUMPS
Regulation (EU) n. 547/2012 Annex II point 2 (Product information requirements)
1) Minimum efficiency index (50 Hz):
e-SVTM High Pressure: not included in the sphere of application of the Regulations.
e-SVTM Low NPSH: see the MEI column in the tables in the Weights and dimensions at 50 Hz, 2 poles section.
e-SVTM High Temperature (...150C or ...180C): see the MEI column in the tables in the Hydraulic
Performance at 50 Hz, 2 poles section.
e-SVTM with HYDROVAR: see the MEI column of the table in the Electrical data at 50 Hz, 2 poles section.
e-SVTM 4-pole version: not included in the sphere of application of the Regulations.
e-SVTM Reducing Footprint: see the MEI column in the table in the Hydraulic performance at 50 Hz, 2 poles
section.
e-SVTM Horizontal installation: see NOTE (50 Hz) in the Operating characteristics section.
2) The benchmark for most efficient water pumps is MEI 0,70.
3) Year of manufacture: from January 2013.
4) Manufacturer: Lowara srl Unipersonale - Reg. No. 03471820260 - Montecchio Maggiore, Vicenza, Italy.
5) Product type identification:
e-SV High Pressure: not included in the sphere of application of the Regulations.
e-SV Low NPSH: see the PUMP TYPE column in the tables in the Weights and dimensions at 50 Hz, 2 poles
section.
e-SV High Temperature (...150C or ...180C): see the PUMP TYPE column in the tables in the Hydraulic
Performance at 50 Hz, 2 poles section.
e-SV with HYDROVAR: see the PUMP TYPE column in the table in the Electrical data at 50 Hz, 2 poles
section.
e-SV 4-pole version: not included in the sphere of application of the Regulations.
e-SV Reducing Footprint: see the PUMP TYPE column in the table in the Hydraulic Performance at 50 Hz, 2
poles section.
e-SV Horizontal Installation: see the NOTE (50 Hz) in the Operating characteristics section.
6) Hydraulic pump efficiency with trimmed impeller: not applicable to these products.
7) Pump performance curves, including the performance curve:
e-SV High Pressure: not included in the sphere of application of the Regulations.
e-SV Low NPSH: see the Operating Characteristics at 50 Hz, 2 poles graphs.
e-SV High Temperature (...150C or ...180C): see the table in the Hydraulic Performance at 50 Hz, 2 poles
section.
e-SV with HYDROVAR: see the table in the Electrical data at 50 Hz, 2 poles section.
e-SV 4-pole version: not included in the sphere of application of the Regulations.
e-SV Reducing Footprint: see the table in the Hydraulic Performance at 50 Hz, 2 poles section.
e-SV Horizontal Installation: see the NOTE (50 Hz) in the Operating characteristics section.
8) The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller
diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy
consumption. The minimum efficiency index (MEI) is based on the full impeller diameter.
9) The operation of this water pump with variable duty points may be more efficient and economic when
controlled, for example, by the use of a variable speed drive that matches the pump duty to the system.
10) Information relevant for disassembly, recycling or disposal at end-of-life: observe the current laws and by-laws
governing sorted waste disposal. Consult the product operating manual.
11) Designed for use below 10 C only: note not applicable to these products.
12) Designed for use above 120 C only: note not applicable to these products.
13) Specific instructions for pumps as per points 11 and 12: not applicable to these products.
14) Information on benchmark efficiency is available at: www.europump.org (Ecodesign section).
15) The benchmark efficiency graphs with MEI = 0.7 and MEI = 0.4 are available at
www.europump.org/efficiencycharts (refer to Multistage Vertical 2900 rpm).

MATERIALI 1-22 SV VERSIONI


T,, R VERSIONS
F, T
REF.

NAME

F-T-R
REFERENCE STANDARDS

MATERIAL

N.

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

EUROPE

Pump body
Impeller
Diffuser
Outer sleeve
Shaft
Adapter
Base
Coupling
Seal housing
Mechanical seal
Elastomers
Coupling protection
Shaft sleeve and bushing
Fill / drain plugs
Tie rods
Wear ring

Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Cast iron
Aluminium
Aluminium
Stainless steel
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel
Tungsten carbide
Stainless steel
Galvanized steel
Technopolymer PPS

MATERIALI 1-22SV VERSIONI


V,, C, K VERSIONS
N, V
REF.

NAME

AISI 304
AISI 304
AISI 304
AISI 304
AISI 304
ASTM Class 35
AISI 304

EN 10088-1-X5CrNi18-10 (1.4301)

AISI 304

EN 10088-1-X5CrNi18-10 (1.4301)
EN 10277-3-36SMnPb14 (1.0765)

AISI 304

N-V-C-K

1-22sv-ftr-en_a_tm

REFERENCE STANDARDS

MATERIAL

N.

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

EUROPE

Pump body
Impeller
Diffuser and upper spacer
Outer sleeve
Shaft
Adapter
Base
Coupling
Seal housing
Mechanical seal
Elastomers
Coupling protection
Shaft sleeve and bushing
Fill / drain plugs
Tie rods
Wear ring

USA

EN 10088-1-X5CrNi18-10 (1.4301)
EN 10088-1-X5CrNi18-10 (1.4301)
EN 10088-1-X5CrNi18-10 (1.4301)
EN 10088-1-X5CrNi18-10 (1.4301)
EN 10088-1-X5CrNi18-10 (1.4301)
EN 1561-GJL-250 (JL1040)
EN 1706-AC-AlSi11Cu2 (Fe) (AC46100)
EN 1706-AC-AlSi11Cu2 (Fe) (AC46100)
EN 10088-1-X5CrNi18-10 (1.4301)

Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Cast iron
Aluminium
Aluminium
Stainless steel
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel
Tungsten carbide
Stainless steel
Stainless steel
Technopolymer PPS

USA

EN 10088-1-X2CrNiMo17-12-2 (1.4404)
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
EN 1561-GJL-250 (JL1040)
EN 1706-AC-AlSi11Cu2 (Fe) (AC46100)
EN 1706-AC-AlSi11Cu2 (Fe) (AC46100)
EN 10088-1-X2CrNiMo17-12-2 (1.4404)

AISI 316L
AISI 316L
AISI 316L
AISI 316L
AISI 316
ASTM Class 35
AISI 316L

EN 10088-1-X5CrNi18-10 (1.4301)

AISI 304

EN 10088-1-X5CrNiMo17-12-2 (1.4401)
EN 10088-1-X17CrNi16-2 (1.4057)

AISI 316
AISI 431
1-22sv-nvck-en_a_tm

INTRODUCT
ION
INTRODUCTION

1, 3, 5SV SERIES and 10, 15, 22SV SERIES 4 kW


ELECTRIC PUMP CROS
S SECTION AND MAIN COMPONENTS
CROSS

INTRODUCT
ION
INTRODUCTION

10, 15, 22SV SERIES 5,5 kW


ELECTRIC PUMP CROS
S SECTION AND MAIN COMPONENTS
CROSS

MATERIALI 10-22 SV VERSIONI

F, T
T,, R VERSIONS
REF.

NAME

F-T-R
REFERENCE STANDARDS

MATERIAL

N.

EUROPE

1
Pump body
2
Impeller
3
Diffuser
4
Outer sleeve
5
Shaft
6
Adapter
7
Base
8
Coupling
9
Seal plate
10
Mechanical seal
11
Elastomers
12
Coupling protection
13
Shaft sleeve and bushing
14
Fill / drain plugs
15
Tie rods
16
Wear ring
17
Seal gland 10-22SV
MATERIALI

Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Cast iron
Aluminium
Aluminium
Stainless steel
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel
Tungsten carbide
Stainless steel
Stainless steel
Technopolymer PPS
Stainless steelN-V-C-K
VERSIONI

AISI 304
AISI 304
AISI 304
AISI 304
AISI 304
ASTM Class 35
AISI 304

EN 10088-1-X5CrNi18-10 (1.4301)

AISI 304

EN 10088-1-X5CrNi18-10 (1.4301)
EN 10277-3-36SMnPb14 (1.0765)

AISI 304

EN 10213-4-GX5CrNi19-10 (1.4308)

AISI 304

N, V
V,, C, K VERSIONS
REF.

NAME

10-22sv-ftr-en_a_tm

REFERENCE STANDARDS

MATERIAL

N.

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

EUROPE

Pump body
Impeller
Diffuser
Outer sleeve
Shaft
Adapter
Base
Coupling
Seal plate
Mechanical seal
Elastomers
Coupling protection
Shaft sleeve and bushing
Fill / drain plugs
Tie rods
Wear ring
Seal gland

USA

EN 10088-1-X5CrNi18-10 (1.4301)
EN 10088-1-X5CrNi18-10 (1.4301)
EN 10088-1-X5CrNi18-10 (1.4301)
EN 10088-1-X5CrNi18-10 (1.4301)
EN 10088-1-X5CrNi18-10 (1.4301)
EN 1561-GJL-250 (JL1040)
EN 1706-AC-AlSi11Cu2 (Fe) (AC46100)
EN 1706-AC-AlSi11Cu2 (Fe) (AC46100)
EN 10088-1-X5CrNi18-10 (1.4301)

Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Cast iron
EN 1561-GJL-250 (JL1040)
Aluminium
EN 1706-AC-AlSi11Cu2 (Fe) (AC46100)
Aluminium
EN 1706-AC-AlSi11Cu2 (Fe) (AC46100)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Tungsten carbide
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Stainless steel
EN 10088-1-X17CrNi16-2 (1.4057)
Technopolymer PPS
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)

USA

AISI 316L
AISI 316L
AISI 316L
AISI 316L
AISI 316
ASTM Class 35
AISI 316L

AISI 304
AISI 316
AISI 431
AISI 316
10-22sv-nvck-en_a_tm

10

MATERIALI 33-92SV

G VERSIONS
REF.

NAME

VERSIONI

G
REFERENCE STANDARDS

MATERIAL

N.

1
1A
2
3
4
5
6
7
8
9
9A
10
11
12
13
14
15
16

EUROPE

Pump body
Lower support
Impeller
Diffuser
Outer sleeve
Shaft
Adapter
Wear ring
Coupling
Upper head
Seal housing
Mechanical seal
Elastomers
Coupling protection
Shaft sleeve and bushing
Bushing for diffuser
Fill / Drain plugs
Tie rods

Cast iron
EN 1561-GJL-250 (JL1040)
Cast iron
EN 1561-GJL-250 (JL1040)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Stainless steel
EN 10088-1 - X17CrNi16-2 (1.4057)
Cast iron
EN 1561-GJL-200 (JL1030)
Technopolymer PPS
Cast iron
EN 1561-GJL-200 (JL1030)
Cast iron
EN 1561-GJL-250 (JL1040)
Cast iron
EN 1561-GJL-250 (JL1040)
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Tungsten carbide
Carbon
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Galvanized steel
EN 10277-3-36SMnPb14 (1.0765)

MATERIALI 33-92SV VERSIONI

N VERSIONS
REF.

NAME

ASTM Class 25
ASTM Class 35
ASTM Class 35

AISI 304

AISI 316
-

33-92sv-g-en_a_tm

REFERENCE STANDARDS

MATERIAL

N.

1
1A
2
3
4
5
6
7
8
9
9A
10
11
12
13
14
15
16

USA

ASTM Class 35
ASTM Class 35
AISI 316L
AISI 304
AISI 304
AISI 431
ASTM Class 25

EUROPE

Pump body
Lower support
Impeller
Diffuser
Outer sleeve
Shaft
Adapter
Wear ring
Coupling
Upper head
Seal housing
Mechanical seal
Elastomers
Coupling protection
Shaft sleeve and bushing
Bushing for diffuser
Fill / drain / air plugs
Tie rods

Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Cast iron
EN 1561-GJL-200 (JL1030)
Technopolymer PPS
Cast iron
EN 1561-GJL-200 (JL1030)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Tungsten carbide
Carbon
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Stainless steel
EN 10088-1-X17CrNi16-2 (1.4057)

USA

ASTM CF8M (AISI 316 cast)


ASTM CF8M (AISI 316 cast)
AISI 316L
AISI 316L
AISI 316L
UNS S 31803
ASTM Class 25
ASTM Class 25
ASTM CF8M (AISI 316 cast)
ASTM CF8M (AISI 316 cast)

AISI 304

AISI 316
AISI 431
33-92sv-n-en_a_tm

11

INTRODUCT
ION
INTRODUCTION

33, 46, 66, 92SV SERIES


ELECTRIC PUMP CROS
S SECTION AND MAIN COMPONENTS
CROSS

INTRODUCT
ION
INTRODUCTION

125SV SERIES
ELECTRIC PUMP CROS
S SECTION AND MAIN COMPONENTS
CROSS

MATERIALI 125 SV

G VERSIONS
REF.

VERSIONI

NAME

G
REFERENCE STANDARDS

MATERIAL

N.

1
1A
2-3
4
5
6
7
8
9-9A
10
11
12
13
14
15
16
17

EUROPE

Pump body
Lower support
Impeller, Diffuser
Outer sleeve
Shaft
Adapter ( up to 45kW )
Adapter ( for higher powers )
Wear ring
Coupling ( up to 45kW )
Coupling ( for higher powers )
Upper head, Seal housing
Mechanical seal
Elastomers
Coupling protection
Shaft sleeve and bushing
Bushing for diffuser
Fill / drain / air plugs
Tie rods
Adapter ring

Cast iron
EN 1561-GJL-250 (JL1040)
Stainless steel
EN 10213-GX5CrNi19-10 (1.4308)
Stainless steel
EN 10213-GX5CrNi19-10 (1.4308)
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Stainless steel
EN 10088-1 - X17CrNi16-2 (1.4057)
Cast iron
EN 1561-GJL-200 (JL1030)
Cast iron
EN 1563-GJS-500-7 (JS1050)
Technopolymer PPS
Cast iron
EN 1561-GJL-200 (JL1030)
Cast iron
EN 1563-GJS-500-7 (JS1050)
Cast iron
EN 1561-GJL-250 (JL1040)
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Tungsten carbide
Carbon
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Galvanized steel
EN 10277-3-36SMnPb14 (1.0765)
Stainless steel
EN 10213-GX5CrNi19-10 (1.4308)

MATERIALI 125SV VERSIONI

N VERSIONS
REF.

NAME

6
7
8
9-9A
10
11
12
13
14
15
16
17

ASTM Class 25
ASTM A 536 80-55-06
ASTM Class 35

AISI 304

AISI 316
AISI 304
125sv-g-en_a_tm

REFERENCE STANDARDS

MATERIAL

N.

1
1A
2-3
4
5

USA

ASTM Class 35
AISI 304
AISI 304
AISI 304
AISI 431
ASTM Class 25
ASTM A 536 80-55-06

EUROPE

Pump body
Lower support
Impeller, Diffuser
Outer sleeve
Shaft
Adapter
Adapter
Wear ring
Coupling
Coupling
Upper head, Seal housing
Mechanical seal
Elastomers
Coupling protection
Shaft sleeve and bushing
Bushing for diffuser
Fill / drain / air plugs
Tie rods
Adapter ring

Stainless steel
Stainless steel
Stainless steel
Stainless steel
Duplex stainless steel
Cast iron
Cast iron
Technopolymer PPS
Cast iron
Cast iron
Stainless steel
Silicon carbide / Carbon
EPDM
Stainless steel
Tungsten carbide
Carbon
Stainless steel
Stainless steel
Stainless steel

EN
EN
EN
EN
EN
EN
EN

10213-4-GX5CrNiMo19-11-2 (1.4408)
10213-4-GX5CrNiMo19-11-2 (1.4408)
10213-4-GX5CrNiMo19-11-2 (1.4408)
10088-1-X2CrNiMo17-12-2 (1.4404)
10088-1-X2CrNiMoN22-5-3 (1.4462)
1561-GJL-200 (JL1030)
1563-GJS-500-7 (JS1050)

EN 1561-GJL-200 (JL1030)
EN 1563-GJS-500-7 (JS1050)
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
/ EPDM

USA

ASTM CF8M (AISI 316)


ASTM CF8M (AISI 316)
ASTM CF8M (AISI 316)
AISI 316L
UNS S 31803
ASTM Class 25

ASTM Class 25
ASTM CF8M (AISI 316)

EN 10088-1-X5CrNi18-10 (1.4301)

AISI 304

EN 10088-1-X5CrNiMo17-12-2 (1.4401)
EN 10088-1-X17CrNi16-2 (1.4057)
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)

AISI 316
AISI 431
ASTM CF8M (AISI 316)
125sv-n-en_a_tm

12

1, 3, 5SV (all models)


10, 15, 22SV 4 kW

10, 15, 22SV 5,5 kW

33, 46, 66, 92, 125SV

TENUTA MECCANICA SV MATERIALI

LIST OF MA
TERIALS
MATERIALS
POSITION 1 - 2

POSITION 3

Q 1 : Silicon Carbide
B : Resin impregnated carbon
C : Special resin impregnated carbon

TENUTA MECCANICA SV COMBINAZIONI

E
V
T

POSITION 4 - 5
G

: EPDM
: FPM
: PTFE

: AISI 316

TYPE OF SEAL
TYPE

ROTATING PART

STATIONARY PART

Q1 B E G G

Q1

Q1 Q1 E G G
Q1 B V G G
Q1 Q1 V G G
*Q 1 C T G G
*Q 1 Q1 T G G

Q1
Q1
Q1
Q1
Q1

sv_ten-mec-en_a_tm

POSITION
3
ELASTOMERS

TEMPERATURE
4

SPRINGS

OTHER COMPONENTS

STANDARD MECHANICAL SEAL


B
E
G
OTHER TYPES OF AVAILABLE MECHANICAL SEAL
Q1
E
G
B
V
G
Q1
V
G
C
T
G
Q1
T
G

* Versions with anti-rotation lock pin of the fixed part.

( C )

-30 +120

G
G
G
G
G

-30
-10
-10
0
0

+120
+120
+120
+120
+120

sv_tipi-ten-mec-en_b_tc

PRES
SURE/TEMPERA
TURE APPLICA
TION LIMITS FOR COMPLETE PUMP
PRESSURE/TEMPERA
SURE/TEMPERATURE
APPLICATION
(APPLICABLE WITH ANY OF THE SEALS LISTED ABO
VE)
ABOVE)

13

INTRODUCT
ION
INTRODUCTION

e-SV SERIES
MECHANICAL SEALS, ACCORDING TO EN 12756

INTRODUCT
ION
INTRODUCTION

COMP
ATIBILITY CHART FOR MA
TERIALS IN CONT
ACT WITH
COMPA
MATERIALS
CONTACT
TABELLA DI COMPATIBILITA' DEI MATERIALI A CONTATTO CON I PRINCIPALI LIQUIDI
MOST COMMONL
Y USED LIQUIDS
COMMONLY
LIQUID

CONCENTRATION

TEMPERAT.

SPECIF.

MIN/MAX

WEIGHT

(%)

(C)

Acetic acid

80

-10 +70

Alkaline degreaser

80

1,05

Aluminium sulfate

30

-5 +50

2,71

25

-20 +50

0,99

Ammonium sulfate

10

-10 +60

1,77

Boric acid
Butyl alcohol

VERSION

3
(Kg/dm ) Standard

Ammonia in water
Benzoic acid

1, 3, 5, 10, 15, 22 SV 33, 46, 66, 92, 125 SV RECOMMEND. ELASTOM.

SEAL
N

Q1BEGG

Q1Q1VGG

Q1Q1EGG

Q1BEGG

Q1Q1EGG

E
V

VERSION
Standard

70

0 +70

1,31

Q1BVGG

saturated

-10 +90

1,43

Q1Q1VGG

100

-5 +80

0,81

Q1BVGG

Caustic soda

25

0 +70

2,13

Q1Q1EGG

Chloroform

100

-10 +30

1,48

Q1BVGG

1,54

Q1BEGG

Q1Q1VGG

Citric acid

-10 +70

Cleaning products

10

-5 +100

Copper sulfate

20

0 +30

2,28

Q1Q1VGG

Cutting fluid

100

-5 +110

0,90

Q1BVGG

Deionised, demineralised
water

100

-25 +110

Q1BEGG

Denatured alcohol

100

-5 +70

0,81

Q1BEGG

Diathermic oil

100

-5 +110

0,90

Q1BVGG

Q1BVGG

0,81

Q1BEGG

Q1BEGG

Q1Q1TGG

Q1BEGG

Emulsion oil and water

any

-5 +90

Ethyl alcohol

100

-5 +40

Ethylene glycol

30

-30 +120

Formaldehyde

100

0 +30

1,13

-15 +25

1,22

Glycerine

100

+20 +90

1,26

Q1BEGG

Hydraulic oil

100

-5 +110

Q1BVGG

Hydrochloric acid

-5 +25

Q1Q1VGG

Hydroxide sodium

25

0 +70

Q1Q1EGG

Iron sulfate

10

-5 +30

2,09

Q1BEGG

Methyl alcohol

100

-5 +40

0,79

Q1BEGG

Mineral oil

100

-5 +110

0,94

Q1BVGG

Q1Q1VGG

Q1BVGG

Q1Q1VGG

Q1BEGG

Formic acid

1,20

Nitric acid

50

-5 +30

1,48

Perchloroethylene

100

-10 +30

1,60

Phosphates-polyphosphates

10

-5 +90

Phosphoric acid

10

-5 +30

1,33

Propyl alcohol (Propanol)

100

-5 +80

0,80

Propylene glycol

30

-30 +120

Sodium bicarbonate
(Baking soda)

Q1BEGG

Q1BEGG

Q1BEGG

E
V

saturated

-10 +25

Q1Q1VGG

Sodium nitrate

saturated

-10 +80

2,25

Q1BEGG

Sodium sulfate

15

-10 +40

2,60

Q1Q1EGG

Sulphuric acid

-10 +25

1,84

Tannic acid

20

0 +50

Tartaric acid

50

-10 +25

1,76

Sodium hypochlorite

Q1BVGG

Q1BEGG

Q1Q1VGG

Q1BVGG

Q1BEGG

Trichloroethylene

100

-10 +40

1,46

Uric acid

80

-10 +80

1,89

Vegetable oil

100

-5 +110

0,95

Q1BEGG

Water

100

-5 +120

Q1BEGG

Water condensate

100

-5 +100

Q1BEGG

Water detergents, mineral


oils mixture

10

-5 +80

Q1Q1VGG

tab-comp-sv-en_b_tm

The above table indicates the compatibility of materials depending on the pumped liquid.
Check the specific weight of the liquid or the viscosity as this could affect the power input of the motor
and hydraulic performance. For further details, please contact the sales network.

14

15

HIGH
PRES
SURE
PRESSURE

HIGH
PRESSURE
(50/60 Hz)

e-SV SERIES - HIGH PRES


SURE
PRESSURE
50/60 Hz

HIGH
SURE
PRES
PRESSURE

Background and context


In the water treatment industry (Ultra or Nano filtration,
reverse osmosis) in the washing and cleaning industry
(High pressure washdown systems) or with boiler-feed
application, high pressure is mandatory to ensure
consistency in the performance of the systems. Therefore
Lowara has developed e-SVTM High Pressure: a wide range
of pumps and pump systems able to deliver robust and
durable performances up to 45 bar.

Benefits of e-SVTM HIGH PRES


SURE
PRESSURE

Versatile range
range: e-SVTM High Pressure is available in
two different configurations: single pump solution or
tandem pump solution (two pumps in series). If the inlet
pressure value is already high, Lowara delivers a single
pump able to withstand the high inlet pressure and deliver
up to 45 bar pressure at the outlet. With applications
where the high pressure has to be delivered starting from
atmospheric pressure in the inlet, Lowara delivers the Special features / product benefits
tandem solution able to deliver up to 45 bar pressure at
Double sleeve design to withstand high pressure up
-Double
the outlet of the system.
to 45 bar.
- Balanced standard mechanical seal (EN12756)
TM
Long lasting performances
performances: e-SV High Pressure
on all models. Easy to replace
replace, without removing
benefits of a particular design of the sleeve to withstand
the motor from 5,5 kW.
the internal pressure without any limitation in the inlet
- Hard material intermediate bush bearing
pressure but with maximum 45 bar measured at the outlet.
(Tungsten Carbide) to improve lifetime and capacity
The specific balanced mechanical seal and the balanced
of working in extreme conditions, available on all sizes.
design of the impeller and the hard material intermediate
- Balanced impeller design to reduce axial thrust for
TM
bush bearing allows e-SV withstanding up to 45 bar
longer standard motor bearing life.
without stressing the motor and the pump components,
- Wide range of size to cover all requested duty points:
with a direct consequence on the reduction of the life
from 1SV to 125SV.
cycle cost.
- IE2 or IE3 standard motors
motors, 3-phase, 2-poles from
0,75 kW to 55 kW with blocked bearing to support
TM
Easy installation and maintenance
maintenance: e-SV High
maximum thrust without limiting inlet
Pressure in tandem system is composed of two identical
pressure
pressure.
standard e-SVTM High Pressure pumps making replacement
TM
i-ALERT
device to reduce life cycle costs by increasing
TM
easy and cost-effective. e-SV High Pressure in tandem
Mean time between Failures (MTBF).
has to be ordered as two single e-SVTM High Pressure
pumps together with the specific accessories for the
Special configurations
installation (see specific accessories section).
e-SVTM High Pressure offers a wide range of configurations:
- Materials used: see the Materials section.
Code identification
- Options for mechanical seals and gaskets:
P in
e-SVTM High Pressure design is identified with a P
see the mechanical seals and gaskets section.
the product codification of the whole e-SVTM range.
- Options for motors and configuration:
see the motors section.
P015T
Example: 3SV13P
- HYDROVARTM system included: see the e-SVH section
P = High Pressure version.
(e-SVTM with HYDROVARTM).

16

e-SV SERIES - HIGH PRES


SURE
PRESSURE
50/60 Hz
Technical characteristics - Design

HIGH
PRES
SURE
PRESSURE

1: Double sleeve design for optimized resistance


to pressure up to 45 bar.

2: Balanced mechanical seal to withstand


high pressure.

Operating characteristics for single


pump
For the hydraulic performances of the single pump,
please refer to the standard catalogue of e-SVTM.

- - -

TECHNICAL CHARACTERISTIC
S
CHARACTERISTICS
P VERSIONS - 50 Hz
Max efficiency flow (m/h)
Flow range (m/h)
Maximum head (m)

1SV

3SV

5SV

1,7

5,5

10SV

0,72,4 1,24,4 2,48,5


450

440

450

15SV

Motor power (kW)

22SV

33SV

..
46SV

66SV

92SV

125SV

90

120

10,5

16,5

20,5

31

43

72

514

824

1129

1540

2260

3085

450

450

430

450

450

450

430

370

345

445

5,545

7,555

79

78

80

78

45120 60160

45

PN (bar)
Max ( % ) of pump
Standard temperature of
pumped liquid (C)
Standard ambient temp. (C)

0,372,2 0,373 0,375,5 0,7511 1,115 1,118,5 2,230


50

60

70

71

72

73

77

-30 +120
-15 +40
No minimum inlet pressure required with Lowara motors

Inlet min. pressure (bar)

No variation according to e-SV N version (AISI 316)

Material execution
Mechanical seal
configuration

Balanced mechanical seal. Standard materials: Silicon Carbide / Carbon / EPDM

Flange configuration

- - -

Victaulic coupling (1, 3, 5, 10, 15, 22SV versions)


- Round
- flange
- (33,
- 46,-66, 92,
- 125SV
- versions)..
svp-50-en b tg

P VERSIONS - 60 Hz
Max efficiency flow (m/h)
Flow range (m/h)
Maximum head (m)

1SV

3SV

3,6

5SV

0,82,8 1,45,2
450

440

10SV

15SV

Motor power (kW)

Inlet min. pressure (bar)


Material execution
Mechanical seal
configuration
Flange configuration

33SV

46SV

66SV

92SV

125SV

87

108

144

12,4

21,8

24,5

40

50

310

617

1029

1334

1848

2772

450

450

450

450

450

450

430

330

360

337

5,545

7,545

1145

1555

77

79

78

80

78

36102 54144 60160

45

PN (bar)
Max ( % ) of pump
Standard temperature of
pumped liquid (C)
Standard ambient temp. (C)

22SV

0,373
50

0,374 0,555,5 0,7511 1,518,5 2,218,5


60

70

71

72

73
-30 +120
-15 +40

No minimum inlet pressure required with Lowara motors


No variation according to e-SV N version (AISI 316)
Balanced mechanical seal. Standard materials: Silicon Carbide / Carbon / EPDM
Victaulic coupling (1, 3, 5, 10, 15, 22SV versions)
Round flange (33, 46, 66, 92, 125SV versions)
svp-60-en b tg

17

e-SV SERIES - HIGH PRES


SURE
PRESSURE
BALANCED MECHANICAL SEALS, ACCORDING TO EN 12756
33, 46, 66, 92, 125SV

HIGH
SURE
PRES
PRESSURE

1, 3, 5, 10, 15, 22SV

TENUTA MECCANICA SV MATERIALI

LIST OF MA
TERIALS
MATERIALS
POSITION 1 - 2

POSITION 3

Q 1 : Silicon Carbide
B : Resin impregnated carbon

E
V

POSITION 4 - 5
G

: EPDM
: FPM

TENUTA MECCANICA SV COMBINAZIONI

TYPE OF SEAL
TYPE

ROTATING PART

STATIONARY PART

Q1 B E G G

Q1

Q1 Q1 E G G
Q1 B V G G
Q1 Q1 V G G

Q1
Q1
Q1

: AISI 316

1-125sv-p_ten-mec-en_a_tm

POSITION
3
ELASTOMERS

TEMPERATURE
4

SPRINGS

OTHER COMPONENTS

STANDARD MECHANICAL SEAL


B
E
G
OTHER TYPES OF AVAILABLE MECHANICAL SEAL
Q1
E
G
B
V
G
Q1
V
G

( C )

-30 +120

G
G
G

-30 +120
-10 +120
-10 +120
1-125sv-p_tipi-ten-mec-en_a_tc

PRES
SURE/TEMPERA
TURE APPLICA
TION LIMITS FOR COMPLETE PUMP
PRESSURE/TEMPERA
SURE/TEMPERATURE
APPLICATION
(APPLICABLE WITH ANY OF THE SEALS LISTED ABO
VE)
ABOVE)

18

SV
..P SERIES - HIGH PRES
SURE
SV..P
PRESSURE
HYDRA
ULIC PERFORMANCE RANGE A
T 50 Hz
HYDRAULIC
AT
3

10

20

10

30

20

30

40

40

50

50

60

60

100 Q [Imp gpm] 200

80

100 Q [US gpm]

80

200

300

300

400

400

500 600

500 600

H [ft]

H [m]

500

HIGH
PRES
SURE
PRESSURE

400

1000

15SV..P
22SV..P

10SV..P

800

600

500

125SV..P

92SV..P

5SV..P

3SV..P

200

1SV..P

66SV..P

46SV..P

33SV..P

300

100

400

0.7 0.8 0.9 1

20

30

40

50

60

80

8 9 10

20

100

200

300

30

400

40

50

500 600

60 70 80 90100

800 1000

Q [l/min]

06098_B_CH

300
3

Q [m /h]

2000

SV
..P SERIES - HIGH PRES
SURE
SV..P
PRESSURE
HYDRA
ULIC PERFORMANCE RANGE A
T 60 Hz
HYDRAULIC
AT
3

10

20

10

30

20

30

40

40

50

50

60

60

80

100 Q [Imp gpm] 200

100 Q [US gpm] 200

80

300

300

400

400

500 600

500 600

800

500

H [ft]

H [m]

400

1000

600

92SV..P

125SV..P

66SV..P

800

46SV..P

15SV..P
22SV..P

10SV..P

5SV..P

200

3SV..P

1SV..P

33SV..P

300

500

400

100

20

30

40

50

60

80

100

8 9 10

20

200

19

300

30

400

40

500 600

50

60 70 80 90100

800 1000

Q [l/min]

Q [m /h]

2000

200

3000

06099_B_CH

300
0.7 0.80.9 1

HIGH
SURE
PRES
PRESSURE

50Hz

1SV
..P SERIES - HIGH PRES
SURE
1SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 1SV-P 2 poli 50 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

1SV19P../D
1SV22P../D
1SV25P../D
1SV27P../D
1SV30P../D
1SV32P..
1SV34P..
1SV37P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

1,1
1,1
1,5
1,5
1,5
2,2
2,2
2,2

80
80
90
90
90
90
90
90

628
688
758
798
858
898
938
998

263
263
263
263
263
298
298
298

129
129
129
129
129
134
134
134

155
155
155
155
155
174
174
174

120
120
140
140
140
140
140
140

17,5
19
21,2
22,2
23,6
24,6
25,6
27

29,1
30,6
34,2
35,2
36,6
42,8
43,8
45,2

Dimensions and weights are related to one electric pump.

1sv-p-2p50-en_b_td

20

1SV
..P SERIES - HIGH PRES
SURE
1SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

0
0

ISO 9906:2012 - Grade 3B

8
8

10 gpm]
Q [Imp
10

12 gpm]
Q [US

460

37P + 37P

H [ft]

H [m]

480

34P + 34P

1400

440
420

32P + 32P

400
380

30P + 30P

1200

360
340

27P + 27P

320

25P + 25P

1000

300
280

22P + 22P

260
240

19P + 19P

220

1SV37

800

200
600

180
160

400

100
0,07

60

40

kW/stage

0,03
6

20

2,4

15
10
5
0
3
Q [m
2,8/h]

40

Q [l/min]

4
2
0
0,0
0

0,4

0,8
10

1,2

1,6

20

2,0
30

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

21

NPSH [ft]

NPSH [m]

0,05

06030_B_CH

Pp [kW]

120

[%]

140

HIGH
PRES
SIURE 50Hz
PRESSIURE

1SV..P

HIGH
SURE
PRES
PRESSURE

50Hz

3SV
..P SERIES - HIGH PRES
SURE
3SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 3SV-P 2 poli 50 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

3SV16P../D
3SV19P..
3SV21P..
3SV23P..
3SV25P..
3SV27P..
3SV29P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

1,5
2,2
2,2
2,2
2,2
3
3

90
90
90
90
90
100
100

578
638
678
718
758
808
848

263
298
298
298
298
298
298

129
134
134
134
134
134
134

155
174
174
174
174
174
174

140
140
140
140
140
160
160

17
18,4
19,4
20,3
21,4
23,4
24,3

36,6
37,6
38,5
39,6
44,4
45,3

Dimensions and weights are related to one electric pump.

3sv-p-2p50-en_c_td

22

3SV
..P SERIES - HIGH PRES
SURE
3SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

10

15

10

15

Q [Imp gpm]
20 Q [US gpm]

1400

420

27P + 27P

400

H [ft]

29P + 29P

440

H [m]

ISO 9906:2012 - Grade 3B

1300
25P + 25P

380

1200

360

23P + 23P

340

1100

21P + 21P

320
300

1000

19P + 19P

280

900

16P + 19P

260
3SV33

800

240
220

700

200
600

180
160

500

400

0,12

70

50

kW/stage

0,04
6

30
15
10
5
0
3
Q [m5 /h]

4
2
0
0
0

1
10

2
20

30

3
40

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

23

50

4
60

70

Q [l/min]
80

NPSH [ft]

NPSH [m]

0,08

06031_B_CH

Pp [kW]

120

[%]

140

HIGH
PRES
SIURE 50Hz
PRESSIURE

3SV..P

HIGH
SURE
PRES
PRESSURE

50Hz

5SV
..P SERIES - HIGH PRES
SURE
5SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 5SV-P 2 poli 50 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

5SV18P..
5SV21P..
5SV23P..
5SV25P..
5SV28P..
5SV30P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

3
3
4
4
4
5,5

100
100
112
112
112
132

723
798
848
898
973
1043

298
298
319
319
319
375

134
134
154
154
154
168

174
174
197
197
197
214

160
160
160
160
160
300

20,4
22,1
23,3
24,4
26,4
31,7

41,4
43,1
49,7
50,8
52,8
69,3

Dimensions and weights are related to one electric pump.

5sv-p-2p50-en_c_td

24

5SV
..P SERIES - HIGH PRES
SURE
5SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

15

10

460

H [m]

10
15

20
20

25

25

30

30

35

Q [Imp 35
gpm]
Q 40
[US gpm]
1500

30P + 30P

440
28P + 28P

1400

420

H [ft]

ISO 9906:2012 - Grade 3B

25P + 28P
400

1300
25P + 25P

380

1200

360

23P + 23P

340

21P + 23P

320

21P + 21P

300

18P + 21P

1000

280

18P + 18P

900

1100

260
5SV33

800

240
220

700

200
600

180
160

500
400

100
0,20

80

0,15

60

0,10

[%]

120

40

kW/stage

20
8

NPSH [ft]

0,05
3

1
0
0

1
20

3
40

4
60

5
80

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

25

6
100

7
120

3
/h]
9 Q [m 10

8
140

Q160
[l/min]

06032_B_CH

NPSH [m]

Pp [kW]

140

HIGH
PRES
SIURE 50Hz
PRESSIURE

5SV..P

HIGH
SURE
PRES
PRESSURE

50Hz

10SV
..P SERIES - HIGH PRES
SURE
10SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 10SV-P 2 poli 50 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

10SV11P..
10SV13P..
10SV15P..
10SV17P..
10SV18P..
10SV20P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

4
5,5
5,5
7,5
7,5
7,5

112
132
132
132
132
132

675
806
870
934
966
1030

319
375
375
367
367
367

154
168
168
191
191
191

197
214
214
256
256
256

160
300
300
300
300
300

27,5
35,8
38,1
40,4
41,5
43,8

54
74
76
97
98
100

Dimensions and weights are related to one electric pump.

10sv-p-2p50-en_c_td

26

10SV
..P SERIES - HIGH PRES
SURE
10SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

0
0

10

20

10

ISO 9906:2012 - Grade 3B

30

20

30

50 Q [Imp gpm]

40
40

60 Q [US gpm]
70

50

460

18P + 20P

440

18P + 18P

420

1500
1400

H [ft]

H [m]

480

17P + 17P

400

1300
15P + 17P

380
360

15P + 15P

1200

340

13P + 15P

1100

320

13P + 13P
1000

300

11P + 13P

280

900

260
10SV21

240

800

220

700

200
600

180
160

500
400

100
0,6

80

60

kW/stage

0,2
3

40
8

NPSH [ft]

0,4

[%]

120

1
0
0

4
50

100

10
150

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

27

12
200

14

Q [m /h]
16
Q
[l/min]
250

06033_B_CH

NPSH [m]

Pp [kW]

140

HIGH
PRES
SIURE 50Hz
PRESSIURE

10SV..P

HIGH
SURE
PRES
PRESSURE

50Hz

15SV
..P SERIES - HIGH PRES
SURE
15SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 15SV-P 2 poli 50 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

15SV09P..
15SV10P..
15SV11P..
15SV13P..
15SV15P..
15SV17P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

7,5
11
11
11
15
15

132
160
160
160
160
160

822
900
948
1044
1140
1236

367
428
428
428
494
494

191
191
191
191
240
240

256
256
256
256
313
313

300
350
350
350
350
350

35,6
40,1
41,7
45
48,4
52

92
111
113
116
151
154

Dimensions and weights are related to one electric pump.

15sv-p-2p50-en_c_td

28

15SV
..P SERIES - HIGH PRES
SURE
15SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

20

40

20

ISO 9906:2012 - Grade 3B

60

40

60

Q [Imp100
gpm]

80
80

Q [US120
gpm]

100

500
1600
15P + 17P

460

1500
15P + 15P

440

H [ft]

H [m]

480

1400

420

13P + 15P

400

1300
13P + 13P

380
360

1200

11P + 13P

340

1100

11P + 11P

320
300

1000

10P + 10P

280

900

09P + 09P

260

15SV17

240

800

220

700

200
600

180
160

500
400

120
1,2

60

kW/stage

0,4
4

40
12
8

4
0

0
0
0

6
100

10

12

14

16

200

18
300

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

29

20

22

24

Q [m /h]
26
28

400

Q [l/min]

NPSH [ft]

0,8

[%]

80

06034_B_CH

NPSH [m]

Pp [kW]

140

HIGH
PRES
SIURE 50Hz
PRESSIURE

15SV..P

HIGH
SURE
PRES
PRESSURE

50Hz

22SV
..P SERIES - HIGH PRES
SURE
22SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 22SV-P 2 poli 50 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

22SV09P..
22SV10P..
22SV12P..
22SV14P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

11
11
15
15

160
160
160
160

852
900
996
1092

428
428
494
494

191
191
240
240

256
256
313
313

350
350
350
350

37,2
40
42,2
45,5

108
111
145
148

Dimensions and weights are related to one electric pump.

22sv-p-2p50-en_b_td

30

22SV
..P SERIES - HIGH PRES
SURE
22SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

0
0

20

40

20

40

60
60

ISO 9906:2012 - Grade 3B


80

80

100

100

Q [Imp
120 gpm]

120

Q [US gpm]
140

460

1500
14P + 14P
1400

420

H [ft]

H [m]

440

12P + 14P

400

1300

380

12P + 12P
1200

360
10P + 12P

340

1100

320

10P + 10P
1000

300
09P + 09P

280

900

260

22SV17
800

240
220

700

200
600

180
160

500

400

120
1,4

60

kW/stage

0,6
6

40
16
12
8
4
0

4
2
0
0
0

10
100

15
200

20
300

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

31

25
400

30

Q [m /h]
35

500

Q [l/min]

NPSH [ft]

1,0

[%]

80

06035_B_CH

NPSH [m]

Pp [kW]

140

HIGH
PRES
SIURE 50Hz
PRESSIURE

22SV..P

HIGH
SURE
PRES
PRESSURE

50Hz

33SV
..P SERIES - HIGH PRES
SURE
33SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 33SV-P 2 poli 50 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSION (mm)

TYPE

33SV7/2AP..
33SV8/1AP..
33SV9P..
33SV10/2AP..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

15
18,5
22
22

160
160
180
180

994
1069
1144
1219

494
494
494
494

240
240
240
240

313
313
313
313

350
350
350
350

88
93
98
103

190
204
219
224

Dimensions and weights are related to one electric pump.

33sv-p-2p50-en_b_td

32

33SV
..P SERIES - HIGH PRES
SURE
33SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

0
0

20

40

20

40

60
60

ISO 9906:2012 - Grade 3B

80
80

100

100

Q
[Imp gpm]
140

120

120

140

gpm]
160 Q [US
180

460

1500

10/2P + 10/2P

440

H [ft]

H [m]

480

9P + 9P
1400

420
8/1P + 9P

400

1300

380

8/1P + 8/1P
1200

360
7/2P + 8/1P

340

1100

320
1000

33SV13/1

300
280

900

260
800

240
220

700

P2 1
P2 /1

kW/stage
1
8

40
20

10

0
0
0

5
100

10

15
200

20
300

25
400

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

33

30
500

35
600

Q 40
[m /h]
Q [l/min]
700

NPSH [ft]

NPSH [m]

60

[%]

80

06036_B_CH

Pp [kW]

200
3

HIGH
PRES
SIURE 50Hz
PRESSIURE

33SV..P

HIGH
SURE
PRES
PRESSURE

50Hz

46SV
..P SERIES - HIGH PRES
SURE
46SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 46SV-P 2 poli 50 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSION (mm)

TYPE

46SV6P..
46SV7P..
46SV8P..
46SV9/2AP..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

22
30
30
30

180
200
200
200

959
1034
1109
1184

494
657
657
657

240
317
317
317

313
402
402
402

350
400
400
400

91
101
106
110

212
327
332
336

Dimensions and weights are related to one electric pump.

46sv-p-2p50-en_b_td

34

46SV
..P SERIES - HIGH PRES
SURE
46SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

50

ISO 9906:2012 - Grade 3B

100

50

150

100

150

200
200

Q [Imp gpm]

250

Q [US gpm]

H [m]

H [ft]

480
460

1500

9/2P + 9/2P
440
420
400
380

8P + 8P

1400

7P + 8P

1300

7P + 7P
1200

360
6P + 7P
340

1100
46SV13/2

320

1000

300
280

900

260
800

240
220

700

200

160
5

90

P2 1

P2 /1

kW/stage

50
20

10

0
0

100

10
200

15

20
300

25
400

30

35

500

600

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

35

40
700

45

50
800

55
900

0
60 Q [m
653/h]
1000 Q [l/min]

NPSH [ft]

1
8

06037_B_CH

NPSH [m]

70

[%]

600

Pp [kW]

180

HIGH
PRES
SIURE 50Hz
PRESSIURE

46SV..P

HIGH
SURE
PRES
PRESSURE

50Hz

66SV
..P SERIES - HIGH PRES
SURE
66SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 66SV-P 2 poli 50 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSION (mm)

TYPE

66SV4P..
66SV5P..
66SV6/1AP..
66SV7/1AP..
66SV8P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

22
30
30
37
45

180
200
200
200
225

879
969
1059
1149
1239

494
657
657
657
746

240
317
317
317
384

313
402
402
402
455

350
400
400
400
450

97
110
119
125
135

218
336
345
380
491

Dimensions and weights are related to one electric pump.

66sv-p-2p50-en_b_td

36

66SV
..P SERIES - HIGH PRES
SURE
66SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

0
0

50

100

50

100

150
150

ISO 9906:2012 -Grade 3B


200

200

250

250

300

300 Q [Imp gpm]


350

Q [US gpm]

500

H [ft]

H [m]

1600

8P + 8P

480
460

1500

7/1P + 8P
440

1400

420

7/1P + 7/1P

400

1300
6/1P + 7/1P

380

1200

360

6/1P + 6/1P

340

1100

5P + 6/1P
320
300
280

5P + 5P

1000

4P + 5P

900

260
240

800

66SV8

220

700

200
600

180
160

500

P2 1

kW/stage

60

[%]

80

P2 /1

40
30
20

10
0

0
0
0

10
200

20

30
400

40

50

600

800

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

37

60
1000

70
1200

80 Q [m /h]
90
Q [l/min]
1400

NPSH [ft]

2
10

06038_B_CH

NPSH [m]

Pp [kW]

140
8

HIGH
PRES
SIURE 50Hz
PRESSIURE

66SV..P

HIGH
SURE
PRES
PRESSURE

50Hz

92SV
..P SERIES - HIGH PRES
SURE
92SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 92SV-P 2 poli 50 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSION (mm)

TYPE

92SV4/2AP..
92SV4P..
92SV5P..
92SV6P..
92SV7/2AP..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

30
30
37
45
45

200
200
200
225
225

879
879
969
1059
1149

657
657
657
746
746

317
317
317
384
384

402
402
402
455
455

400
400
400
450
450

103
103
112
122
128

329
329
367
478
484

Dimensions and weights are related to one electric pump.

92sv-p-2p50-en_b_td

38

92SV
..P SERIES - HIGH PRES
SURE
92SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

0
0

200

100

300

200

300

400

Q [Imp gpm]

500 Q [US gpm]

400

7/2P + 7/2P
1400

420
6P + 6P

400

1300

H [ft]

H [m]

440

100

ISO 9906:2012 - Grade 3B

380
5P + 6P

1200

5P + 5P

1100

4P + 5P

1000

4P + 4P

900

360
340
320
300
280
260
240

800

4/2P + 4/2P

220

700

92SV 7/2

200

600

180
160

500

140
400

120

300
80

kW/stage

70

P2 /1

60

4
8

50
20

10

0
0
0

20

40
500

60

80

1000

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

39

100
1500

0
3
120 Q [m /h]
2000 Q [l/min]

NPSH [ft]

NPSH [m]

P2 1

[%]

80
8

06039_B_CH

Pp [kW]

100

HIGH
PRES
SIURE 50Hz
PRESSIURE

92SV..P

HIGH
SURE
PRES
PRESSURE

50Hz

125SV
..P SERIES - HIGH PRES
SURE
125SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 125SV-P 2 poli 50 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSION (mm)

TYPE

125SV4P..
125SV5P..
125SV6P..
125SV7P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

30
37
45
55

200
200
225
250

1178
1328
1478
1658

657
657
746
825

317
317
384
402

402
402
455
486

400
400
450
550

168
181
198
228

394
436
554
641

Dimensions and weights are related to one electric pump.

125sv-p-2p50-en_b_td

40

125SV
..P SERIES - HIGH PRES
SURE
125SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

0
0

100
100

200
200

300
300

ISO 9906:2012 - Grade 3B


400

400

600 Q [Imp gpm]

500

500

600

700

1200

360

7P + 7P

340

6P + 7P

1100

6P + 6P

1000

320

H [ft]

H [m]

380

Q [US gpm]

300
5P + 6P
900

280
5P + 5P

260

800
240

4P + 5P

220

700
125SV 8/2A

200

600

180
160

500

140
400

120
100

kW/stage

6
12
8
4
0
0
0

20

40
500

60
1000

80

100
1500

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

41

120
2000

140

160
2500

30
20
10
0
3
Q [m
/h]
180
Q [l/min]
3000

[%]

NPSH [ft]

80
70
60
50
40

06040_B_CH

NPSH [m]

Pp [kW]

300
80
8

HIGH
PRES
SIURE 50Hz
PRESSIURE

125SV..P

HIGH
SURE
PRES
PRESSURE

60Hz

1SV
..P SERIES - HIGH PRES
SURE
1SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 1SV-P 2 poli 60 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

1SV15P../D
1SV17P../D
1SV18P..
1SV20P..
1SV22P..
1SV24P..
1SV26P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

1,5
1,5
2,2
2,2
2,2
2,2
2,2

90
90
90
90
90
90
90

558
598
618
658
698
738
778

263
263
298
298
298
298
298

129
129
134
134
134
134
134

155
155
174
174
174
174
174

140
140
140
140
140
140
140

15,8
16,8
17,2
18,2
19,2
20,1
21,1

28,8
28,8
35,4
36,4
37,4
38,3
39,3

Dimensions and weights are related to one electric pump.

1sv-p-2p60-en_c_td

42

1SV
..P SERIES - HIGH PRES
SURE
1SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

ISO 9906:2012 - Grade 3B

8
8

10

10

Q [Imp gpm]

12

Q [US
14gpm]

26P + 26P

460

1500

H [ft]

H [m]

480

24P + 26P

440

1400

24P + 24P

420

22P + 24P
400

1300

22P + 22P

380

20P + 22P

360

20P + 20P

340

18P + 20P

1200

1100

18P + 18P
17P + 18P
17P + 17P

320
300

1000

15P + 17P

280

15P + 15P

900

1SV28

800

260
240
220

700

200
600

180
160

500

140
0,08

kW/stage

0,04
6

20

4
2
0
0,0
0

0,4

0,8
10

1,2

1,6

20

2,0
30

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

43

2,4
40

2,8

15
10
5
0
3
Q 3,2
[m /h]
50 Q [l/min]

NPSH [ft]

NPSH [m]

40

[%]

0,06

06041_B_CH

Pp [kW]

60

HIGH
PRES
SIURE 60Hz
PRESSIURE

1SV..P

HIGH
SURE
PRES
PRESSURE

60Hz

3SV
..P SERIES - HIGH PRES
SURE
3SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 3SV-P 2 poli 60 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

3SV12P..
3SV13P..
3SV14P..
3SV15P..
3SV17P..
3SV19P..
3SV21P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

2,2
2,2
2,2
3
3
3
4

90
90
90
100
100
100
112

498
518
538
568
608
648
688

298
298
298
298
298
298
319

134
134
134
134
134
134
154

174
174
174
174
174
174
197

140
140
140
160
160
160
160

14,2
14,7
15,2
16,1
17
18
19

32,4
32,9
33,4
37,1
38
39
45,4

Dimensions and weights are related to one electric pump.

3sv-p-2p60-en_c_td

44

3SV
..P SERIES - HIGH PRES
SURE
3SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

10

12

10

14

16

15

18

20 Q [Imp gpm]

20

25
Q [US gpm]

420

19P + 19P

400

17P + 19P

380

17P + 17P

360

15P + 17P

340

15P + 15P

320

1400

H [ft]

19P + 21P

440

H [m]

ISO 9906:2012 - Grade 3B

1300

1200

1100

14P + 14P

1000

300
13P + 13P
280

900

12P + 12P
260

3SV23
800

240
220

700

200
600

180
160

500

140
400

120
0,12

50
kW/stage

30
15
10
5
0
3
Q [m
6 /h]

4
2
0
0
0

1
10

2
20

30

3
40

50

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

45

4
60

5
70

80

90

Q 100
[l/min]

NPSH [ft]

0,04
6

06042_B_CH

Pp [kW]
NPSH [m]

0,08

[%]

70

HIGH
PRES
SIURE 60Hz
PRESSIURE

3SV..P

HIGH
SURE
PRES
PRESSURE

60Hz

5SV
..P SERIES - HIGH PRES
SURE
5SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 5SV-P 2 poli 60 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

5SV12P..
5SV13P..
5SV14P..
5SV15P..
5SV16P..
5SV17P..
5SV19P..
5SV21P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

3
4
4
4
4
5,5
5,5
5,5

100
112
112
112
112
132
132
132

573
598
623
648
673
718
768
818

298
319
319
319
319
375
375
375

134
154
154
154
154
168
168
168

174
197
197
197
197
214
214
214

160
160
160
160
160
300
300
300

16,2
16,8
17,3
17,9
18,5
23
24
25,3

37,2
43,2
43,7
44,3
44,9
61
62
63

Dimensions and weights are related to one electric pump.

5sv-p-2p60-en_c_td

46

5SV
..P SERIES - HIGH PRES
SURE
5SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

10

15

10

15

20
20

25

25

30

30

35

35

Q [Imp
40gpm]
Q [US gpm]
45

40

460

21P + 21P

440

19P + 21P

420

19P + 19P

1400

400

17P + 19P

1300

380

17P + 17P

360

16P + 16P

340

15P + 15P

1500

H [ft]

H [m]

ISO 9906:2012 - Grade 3B

1200

320

1100

14P + 14P
1000

300

13P + 13P

280
12P + 12P

900

5SV23

800

260
240
220

700

200
600

180
160

500
400

0,4

80

0,3
0,2

60

[%]

120

40

kW/stage

20
15
10
5
0

4
2
0
0
0

1
20

3
40

4
60

80

100

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

47

7
120

9
140

10
160

113/h]
Q [m
Q180
[l/min]

NPSH [ft]

0,1
6

06043_B_CH

NPSH [m]

Pp [kW]

140

HIGH
PRES
SIURE 60Hz
PRESSIURE

5SV..P

HIGH
SURE
PRES
PRESSURE

60Hz

10SV
..P SERIES - HIGH PRES
SURE
10SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 10SV-P 2 poli 60 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

10SV08P..
10SV09P..
10SV10P..
10SV11P..
10SV13P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

5,5
7,5
7,5
7,5
11

132
132
132
132
160

646
678
710
742
836

375
367
367
367
428

168
191
191
191
191

214
256
256
256
256

300
300
300
300
350

28,6
29,8
30,9
32
37,1

66
86
87
88
108

Dimensions and weights are related to one electric pump.

10sv-p-2p60-en_c_td

48

10SV
..P SERIES - HIGH PRES
SURE
10SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

0
0

10

20

10

30

20

30

ISO 9906:2012 - Grade 3B

40
40

50

50

60

60

70

Q [Imp
70gpm]
Q
80[US gpm]

460

1500

13P + 13P

440
420

H [ft]

H [m]

480

1400

11P + 13P

400

1300

380

11P + 11P

360

10P + 11P

1200

10P + 10P

340

1100

09P + 10P
320

09P + 09P

300

1000

08P + 09P

280

08P + 08P

260

10SV15

900
800

240
220

700

200
600

180
160

500
400

120
1,0
0,8
0,6

60

[%]

80

40

kW/stage

20
10

0
0
0

4
50

6
100

10
150

12
200

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

49

14

16
250

18 Q [m320
/h]
300 Q [l/min]

NPSH [ft]

0,4
4

06044_B_CH

NPSH [m]

Pp [kW]

140

HIGH
PRES
SIURE 60Hz
PRESSIURE

10SV..P

HIGH
SURE
PRES
PRESSURE

60Hz

15SV
..P SERIES - HIGH PRES
SURE
15SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 15SV-P 2 poli 60 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

15SV06P..
15SV07P..
15SV08P..
15SV09P..
15SV10P..
15SV11P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

11
11
15
15
15
18,5

160
160
160
160
160
160

708
756
804
852
900
948

428
428
494
494
494
494

191
191
240
240
240
240

256
256
313
313
313
313

350
350
350
350
350
350

32,5
34,5
36
37,5
39,5
41

103
105
139
140
141
152

Dimensions and weights are related to one electric pump.

15sv-p-2p60-en_b_td

50

15SV
..P SERIES - HIGH PRES
SURE
15SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

20

40

20

40

60
60

80
80

100

100

Q [Imp
120 gpm]

120

Q [US gpm]
140
H [ft]

ISO 9906:2012 - Grade 3B

H [m]

480
460

11P + 11P

440

10P + 11P

420

10P + 10P

400

09P + 10P

380

09P + 09P

360

08P + 09P

340

08P + 08P

320

07P + 08P

300

07P + 07P

1500
1400
1300
1200
1100
1000

280

06P + 07P

900

15SV12

800

260
240
220

700

200
600

180
160

500
400

120
1,6

60

kW/stage

0,8
6

40
16
12
8
4
0

4
2
0
0
0

10
100

15
200

20
300

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

51

25
400

30

Q [m /h]
35

500

Q [l/min]

NPSH [ft]

1,2

[%]

80

06045_B_CH

NPSH [m]

Pp [kW]

140

HIGH
PRES
SIURE 60Hz
PRESSIURE

15SV

HIGH
SURE
PRES
PRESSURE

60Hz

22SV
..P SERIES - HIGH PRES
SURE
22SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 22SV-P 2 poli 60 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

22SV05P..
22SV06P..
22SV07P..
22SV08P..
22SV09P..
22SV10P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

11
11
15
15
18,5
18,5

160
160
160
160
160
160

660
708
756
804
852
900

428
428
494
494
494
494

191
191
240
240
240
240

256
256
313
313
313
313

350
350
350
350
350
350

31,5
33
35
36,5
38
39,5

102
104
137
139
149
151

Dimensions and weights are related to one electric pump.

22sv-p-2p60-en_b_td

52

22SV
..P SERIES - HIGH PRES
SURE
22SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

0
0
460

20
20

40

60

40

60

ISO 9906:2012 - Grade 3B

80
80

100

100

120

120

140

Q [Imp
140gpm]
Q [US gpm]
160

10P + 10P

1500

09P + 10P

1400

420
09P + 09P
400

H [ft]

H [m]

440

1300

08P + 09P
380
360

08P + 08P

340

07P + 08P

320

07P + 07P

300

06P + 07P

280

1200
1100
1000

06P + 06P

260

900

05P + 06P

800

240
22SV10

220

700

200
600

180
160

500
400

2,0

80

60

kW/stage

1,2
10

40
30
20

10
0
0
0

5
100

10

15
200

20
300

25
400

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

53

30
500

35

0
3
Q [m40
/h]

600 Q [l/min]

NPSH [ft]

1,6

[%]

120

06046_B_CH

NPSH [m]

Pp [kW]

140

HIGH
PRES
SIURE 60Hz
PRESSIURE

22SV..P

HIGH
SURE
PRES
PRESSURE

60Hz

33SV
..P SERIES - HIGH PRES
SURE
33SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 33SV-P 2 poli 60 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

33SV5/2AP..
33SV6/2AP..
33SV7/2AP..
33SV7P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

18,5
22
30
30

160
180
200
200

844
919
994
994

494
494
657
657

240
240
317
317

313
313
402
402

350
350
400
400

80
86
96
96

191
208
322
322

Dimensions and weights are related to one electric pump.

33sv-p-2p60-en_b_td

54

33SV
..P SERIES - HIGH PRES
SURE
33SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

50

ISO 9906:2012 - Grade 3B

100

50

150

100

Q [Imp gpm]
Q [US gpm]
200

150

480
460

H [ft]

H [m]

7/2P + 7P
1500

7/2P + 7/2P

440
1400

420

6/2P + 7/2P

400

1300
6/2P + 6/2P

380

1200

360
5/2P + 6/2P
340

1100

320

5/2P + 5/2P
1000

300
280

900

33SV8

260
800

240
220

700

200
600

P2 1

60
P2 /1

kW/stage
1
12

40
30
20
10
0

8
4
0
0
0

8
100

12
200

16

20
300

24

28

400

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

55

32
500

36
600

44 Q [m
48 /h]

40
700

Q 800
[l/min]

NPSH [ft]

NPSH [m]

[%]

80

06047_B_CH

Pp [kW]

180
5

HIGH
PRES
SIURE 60Hz
PRESSIURE

33SV..P

HIGH
SURE
PRES
PRESSURE

60Hz

46SV
..P SERIES - HIGH PRES
SURE
46SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 46SV-P 2 poli 60 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

46SV4P..
46SV5/1AP..
46SV6/2AP..
46SV6P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

30
30
37
37

200
200
200
200

809
884
959
959

657
657
657
657

317
317
317
317

402
402
402
402

400
400
400
400

88
93
98
98

314
319
353
353

Dimensions and weights are related to one electric pump.

46sv-p-2p60-en_b_td

56

46SV
..P SERIES - HIGH PRES
SURE
46SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

50
50

150

100

150

Q
[Imp gpm]
250

200
200

Q [US gpm]
300

250

H [ft]

100

ISO 9906:2012 - Grade 3B

480
6P + 6P

1500

420

6/2P + 6/2P

1400

400

5/1P + 6/2P

1300

5/1P + 5/1P

1200

4P + 5/1P

1100

4P + 4P

1000

H [m]

460
440

380
360
340
320
300
280

900
46SV7

260

800

240
220

700

200
600

180
160

500

60

P2 /1

kW/stage
3
8

50
20

10

0
0
0

10
200

15

20

25
400

30

35

40

600

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

57

45

50
800

55

60
1000

65

0
3
[m /h]
70 Q75
Q [l/min]
1200

NPSH [ft]

NPSH [m]

70

P2 1

[%]

80

06048_B_CH

Pp [kW]

140
7

HIGH
PRES
SIURE 60Hz
PRESSIURE

46SV..P

HIGH
SURE
PRES
PRESSURE

60Hz

66SV
..P SERIES - HIGH PRES
SURE
66SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 66SV-P 2 poli 60 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

66SV3/1AP..
66SV4/2AP..
66SV4P..
66SV5/2AP..
66SV5P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

30
37
37
45
45

200
200
200
250
250

789
879
879
969
969

657
657
657
746
746

317
317
317
384
384

402
402
402
455
455

400
400
400
450
450

97
104
106
116
116

323
359
361
472
472

Dimensions and weights are related to one electric pump.

66sv-p-2p60-en_b_td

58

66SV
..P SERIES - HIGH PRES
SURE
66SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

100

ISO 9906:2012 - Grade 3B

200

100

Q 400
[Imp gpm]

300

200

300

Q [US gpm]

400

440
5P + 5P

1400
H [ft]

H [m]

420

5/2P + 5P

400

1300

380

5/2P + 5/2P

360

4P + 5/2P

340

4P + 4P

320

4/2P + 4P

300

4/2P + 4/2P

1200

1100

1000

280

900

3/1P + 4/2P
260
240

800

3/1P + 3/1P

220

700

66SV 5
200

600

180
160

500

140
400

120

kW/stage

70

[%]

90

P2 1

P2 /1

50
40

10

20

5
0
0
0

10

20

30

40

50

60

500

1000

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

59

70

80

90
1500

100

0
Q 110
[m3/h]

Q [l/min]

NPSH [ft]

4
15

06049_B_CH

NPSH [m]

Pp [kW]

100
10

HIGH
PRES
SIURE 60Hz
PRESSIURE

66SV..P

HIGH
SURE
PRES
PRESSURE

60Hz

92SV
..P SERIES - HIGH PRES
SURE
92SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 92SV-P 2 poli 60 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

92SV2P..
92SV3/2AP..
92SV3/1AP..
92SV3P..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

30
37
37
45

200
200
200
250

699
789
789
789

657
657
657
746

317
317
317
384

402
402
402
455

400
400
400
450

91
97
97
100

317
352
352
456

Dimensions and weights are related to one electric pump.

92sv-p-2p60-en_b_td

60

92SV
..P SERIES - HIGH PRES
SURE
92SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

0
0

100

200

100

ISO 9906:2012 - Grade 3B

300

200

400

300

400

500 Q [Imp gpm]

500

600
Q [US gpm]

340

1100

4/2P + 4/2P

1000

300

3P + 3P

280

H [ft]

H [m]

320

900
3/1P + 3/1P

260
240

3/2P + 3/2P

220

2P + 3/2P

200

2P + 2P

800

700

600

180
160

92SV04/2
500

140
400

120
100

300
80
200
80

10

kW/stage

P2 1

70

P2 /1

60
50
40

10

20

5
0
0
0

20

40
500

60

80

1000

100
1500

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

61

120
2000

0
3
140 Q [m /h]
Q [l/min] 2500

NPSH [ft]

5
15

[%]

15

06050_B_CH

NPSH [m]

Pp [kW]

60

HIGH
PRES
SIURE 60Hz
PRESSIURE

92SV..P

HIGH
SURE
PRES
PRESSURE

60Hz

125SV
..P SERIES - HIGH PRES
SURE
125SV..P
PRESSURE
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 125SV-P 2 poli 60 Hz


MOTOR

PUMP

WEIGHT (Kg)

DIMENSIONS (mm)

TYPE

125SV3/3BP..
125SV3P..
125SV4/4AP..
125SV5/5AP..

ELECTRIC
kW

Size

L1

L2

D1

D2

PUMP

PUMP

30
37
45
55

200
200
225
250

1028
1028
1178
1358

657
657
746
825

317
317
384
402

402
402
455
486

400
400
450
550

155
156
172
198

369
388
534
623

Dimensions and weights are related to one electric pump.

125sv-p-2p60-en_b_td

62

125SV
..P SERIES - HIGH PRES
SURE
125SV..P
PRESSURE
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

0
0

100
100

200
200

300
300

ISO 9906:2012 - Grade 3B


400

400

600 Q [Imp gpm]

500

500

600

700

Q [US gpm]

360

5/5AP + 5/5AP

1100

340
320

H [ft]

H [m]

380

1000

4/4AP + 5/5AP

300
900

4/4AP + 4/4AP

280
260

800

3P + 4/4AP

240
3BP + 3BP

220
200

700

3/3BP + 3/3BP
600

180
125SV5/5A
160

500

140
400

120
100

80

12
10

P2 1
P2 /1A
P2 /1B

kW/stage

40
20

8
4
0
0
0

20

40
500

60
1000

80

100
1500

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

63

120
2000

140

160
2500

30
20
10
0
3
Q [m
/h]
180
Q [l/min]
3000

NPSH [ft]

8
12

60

[%]

14

06051_B_CH

NPSH [m]

Pp [kW]

300

HIGH
PRES
SIURE 60Hz
PRESSIURE

125SV..P

64

HIGH
SURE
PRES
PRESSURE
60Hz

65

LOW
NPSH

LOW NPSH
(50/60 Hz)

ErP 2009/125/EC (50 Hz)


e-SV SERIES - L
OW NPSH
LOW
50/60 Hz
Background and context

LOW
NPSH

In industrial applications, often pumps are exposed to


heavy duty installations and conditions, such as pumping
high temperature liquids (boiler-feed), poor inlet pressure
conditions or high flow rate applications. In these cases,
constant and durable pump operation is often
compromised by cavitation. Therefore Lowara has
developed e-SVTM Low NPSH versions: a pump which
delivers a definitive and valuable solution to solve cavitation
issues in installation.

Benefits of e-SVTM Low NPSH

Consistent operation
operation: the special design of the first
initial stage together with a specific impeller design allows
e-SVTM Low NPSH versions to improve its suction capacity.
Even in critical suction conditions, the pump is able to
deliver consistent and constant operation on the whole
application range.

Long lasting performances


performances: e-SVTM Low NPSH design
ensures consistency in its operation. The specific design Special features / product benefits
of e-SV TM Low NPSH versions saves the pump of the - Specific first stage design to maximize suction
cavitation: the components in the pump are not submitted conditions.
to stress, decreasing the need of repetitive maintenance - Standard mechanical seal (EN12756) fitted on all
and reducing the life cycle cost of the pump.
models. Easy to replace without removing
the motor from 5,5 kW up.
Easy installation
installation: e-SVTM Low NPSH versions is easy to - Hard material intermediate bush bearing
install and allows saving space. Where traditional pumps
(Tungsten Carbide) to improve lifetime and capacity of
will need to have a tank to facilitate the suction conditions, working in extreme conditions, available on all sizes.
the specific design of e-SVTM Low NPSH version allows - Balanced impeller design to reduce axial thrust
installing the pumps without any additional accessories for longer standard motor bearing life.
on the suction side. A compact design where reduced - Wide range of sizes to cover all requested duty
spaces are favored.
points
points: from 1SV to 66SV.
- i-ALERTTM device to reduce life cycle costs by increasing
Code identification
Mean time between Failures (MTBF).
L in the
e-SVTM Low NPSH design is identified with a L
product codification of the whole e-SVTM range.
Special configurations
Example: 3SV13FL
L015T
L = Low NPSH version.

e-SVTM Low NPSH offers a wide range of configurations:


- Materials used: see the Materials section.
- Options for mechanical seals and gaskets:
see the mechanical seals and gaskets section.
- Options for motors and configuration:
see the motors section.
- HYDROVARTM system included: see the e-SVH section
(e-SVTM with HYDROVARTM).

66

e-SV SERIES - L
OW NPSH
LOW
50/60 Hz
Technical characteristics - Design

1: Specific initial impeller design


to maximize suction abilities.

LOW
NPSH

2: Specific initial stage design to enhance


suction capabilities of the pump.

- - - TECHNICAL CHARACTERISTIC
S
CHARACTERISTICS
L VERSIONS - 50 Hz
Max efficiency flow (m/h)
Flow range (m/h)

1SV

3SV

5SV

10SV

..

15SV

22SV

33SV

46SV

66SV

1,7

3,3

5,9

10,5

18

20,5

33

44

75

0,72,4

1,24,4

2,48,5

514

824

1129

1540

2260

3085

Maximum head (m)

230

250

250

250

250

250

310

320

240

Motor power (kW)

0,372,2

0,373

0,755.5

1,511

315

318,5

5,537

7,545

1145

50

62

67

71

70

71

77

76

78

1,12,6

12,4

1,82,5

1,53,3

Max ( % ) of pump
Standard temperature of
pumped liquid (C)
Standard ambient temp. (C)
Min/max NPSHr value (m)

-30 +120
-15 +40
0,40,6

0,50,9

0,41,5

0,51,3

Mechanical seal
configuration
Flange configuration

No variation according to e-SV series


Round flange (F, G, N versions)

- - L VERSIONS - 60 Hz
Max efficiency flow (m/h)
Flow range (m/h)

12

No variation according to e-SV versions: F (AISI 304), G (AISI 304/Ghisa), N (AISI 316)

Material execution

1SV

3SV

5SV

10SV

..

15SV

svL-50-en_b_tg

22SV

33SV

46SV

66SV

2,2

3,9

12,8

22

25

39

53

85

0,82,8

1,45,2

310

617

1029

1334

1848

2772

36102

Maximum head (m)

250

250

250

250

250

220

280

260

200

Motor power (kW)

0,373

0,554

1,17,5

311

418,5

5,522

7,537

1545

18,545

54

63

70

71

70

73

77

76

78

1,63,4

1,33,2

2,23,3

34,3

Max ( % ) of pump
Standard temperature of
pumped liquid (C)
Standard ambient temp. (C)
Min/max NPSHr value (m)

Material execution
Mechanical seal
configuration
Flange configuration

-30 +120
-15 +40
0,50,7

0,81,3

0,92,1

0,81,8

1,32,9

No variation according to e-SV versions: F (AISI 304), G (AISI 304/Ghisa), N (AISI 316)
No variation according to e-SV series
Round flange (F, G, N versions)
svL-60-en_b_tg

67

LOW
NPSH

50Hz

1SV
..L SERIES - L
OW NPSH - 3 TO 15 ST
AGES
1SV..L
LOW
STAGES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 1SV-L 2 poli 50 Hz


PUMP

MOTOR

TYPE

DIMENSIONS (mm)
L2

L1
kW

SIZE

1SV03..L..

0,37

71

1SV04..L..

0,37

1SV05..L..

0,37

1SV06..L..

D1

PESO kg

PN

MEI

bar

(1)

PUMP

PUMP

8,6

13,4

D2

ELECTRIC

1~

3~

1~

3~

1~

3~

278

209

209

111

111

120

120

105

25

0,70

71

298

209

209

111

111

120

120

105

25

0,70

13,8

71

318

209

209

111

111

120

120

105

25

0,70

9,4

14,2

0,37

71

338

209

209

111

111

120

120

105

25

0,70

9,8

14,6

1SV07..L..

0,37

71

358

209

209

111

111

120

120

105

25

0,70

10,2

14,9

1SV08..L..

0,55

71

378

231

231

121

121

140

140

105

25

0,70

10,5

15,2

1SV09..L..

0,55

71

398

231

231

121

121

140

140

105

25

0,70

10,9

15,6

1SV10..L..

0,55

71

418

231

231

121

121

140

140

105

25

0,70

11,3

16

1SV11..L..

0,55

71

438

231

231

121

121

140

140

105

25

0,70

11,7

16,4

1SV12..L../D

0,75

80

468

226

263

121

129

140

155

120

25

0,70

12,7

22,3

1SV13..L../D

0,75

80

488

226

263

121

129

140

155

120

25

0,70

13,1

22,7

1SV15..L../D

0,75

80

528

226

263

121

129

140

155

120

25

0,70

13,9

23,5

(1) Value referred to the F, N versions.

1sv-L1-2p50-en_c_td

68

1SV
..L SERIES - L
OW NPSH - 3 TO 15 ST
AGES
1SV..L
LOW
STAGES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

ISO 9906:2012 - Grade 3B

Q10[Imp gpm]

8
8

Q
12[US gpm]

10

50Hz

1SV..L

H [m]

15

300

LOW
NPSH

90

H [ft]

100

13

80

12
70
11
200

10

60

09
50
08
07

40

06
100

05

30

04
03

20

10

Standard

kW/stage

0,00
NPSH [m]

40

Low

0,05

20
16
12
8
4
0

Standard

4
2

Low

0
0
0

1
10

Q [m /h]3

2
20

30

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

69

40

Q [l/min]
50

NPSH [ft]

0,10

[%]

0
60

06200_B_CH

Pp [kW]

0
0,15

LOW
NPSH

50Hz

1SV
..L SERIES - L
OW NPSH - 17 TO 37 ST
AGES
1SV..L
LOW
STAGES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 1SV-L 2 poli 50 Hz


PUMP

MOTOR

TYPE

DIMENSIONS (mm)
L2

L1
kW

SIZE

1SV17..L../D

1,1

80

1SV19..L../D

1,1

1SV22..L../D

1,1

1SV25..L../D

D1

PN

MEI

WEIGHT kg

D2

ELECTRIC

1~

3~

1~

3~

1~

3~

D2

bar

(1)

PUMP

PUMP

568

263

263

137

129

155

155

120

25

0,70

14,7

26,6

80

608

263

263

137

129

155

155

120

25

0,70

15,5

27,4

80

668

263

263

137

129

155

155

120

25

0,70

16,7

28,6

1,5

90

738

263

263

137

129

155

155

140

25

0,70

18,7

31,7

1SV27..L../D

1,5

90

778

263

263

137

129

155

155

140

25

0,70

19,5

32,5

1SV30..L../D

1,5

90

838

263

263

137

129

155

155

140

25

0,70

20,7

33,7

1SV32..L..

2,2

90

878

298

298

151

134

174

174

140

25

0,70

21,5

37,8

1SV34..L..

2,2

90

918

298

298

151

134

174

174

140

25

0,70

22,3

38,6

1SV37..L..

2,2

90

978

298

298

151

134

174

174

140

25

0,70

23,5

39,8

(1) Value referred to the F, N versions.

1sv-L2-2p50-en_d_td

70

1SV
..L SERIES - L
OW NPSH - 17 TO 37 ST
AGES
1SV..L
LOW
STAGES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

ISO 9906:2012 - Grade 3B

Q10
[Imp gpm]

8
8

Q12
[US gpm]

10

50Hz

1SV..L

240

220
700

200

LOW
NPSH

34

H [ft]

H [m]

37

32
30

180

600

27
160
25
140

500

22

120

400

19
17

100
300
80

200

60

Standard

kW/stage

0,00
NPSH [m]

40

Low

0,05

20
16
12
8
4
0

Standard

Low

0
0
0

1
10

Q [m /h]3

2
20

30

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

71

40

Q [l/min]
50

NPSH [ft]

0,10

[%]

0,15

06201_B_CH

Pp [kW]

60

LOW
NPSH

50Hz

3SV
..L SERIES - L
OW NPSH
3SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 3SV-L 2 poli 50 Hz


PUMP

MOTOR

TYPE

3SV03..L..
3SV04..L..
3SV05..L..
3SV06..L..
3SV07..L../D
3SV08..L../D
3SV09..L../D
3SV10..L../D
3SV11..L../D
3SV12..L../D
3SV13..L../D
3SV14..L../D
3SV16..L../D
3SV19..L..
3SV21..L..
3SV23..L..
3SV25..L..
3SV27..L..
3SV29..L..
3SV31..L..
3SV33..L..

DIMENSIONS (mm)
L2

L1
kW

SIZE

0,37
0,37
0,55
0,55
0,75
0,75
1,1
1,1
1,1
1,1
1,5
1,5
1,5
2,2
2,2
2,2
2,2
3
3
3
3

71
71
71
71
80
80
80
80
80
80
90
90
90
90
90
90
90
100
100
100
100

278
298
318
338
368
388
408
428
448
468
498
518
558
618
658
698
738
788
828
868
908

D1

1~

3~

1~

3~

1~

3~

209
209
231
231
226
226
263
263
263
263
263
263
263
298
298
298
298
-

209
209
231
231
263
263
263
263
263
263
263
263
263
298
298
298
298
298
298
298
298

111
111
121
121
121
121
137
137
137
137
137
137
137
151
151
151
151
-

111
111
121
121
129
129
129
129
129
129
129
129
129
134
134
134
134
134
134
134
134

120
120
140
140
140
140
155
155
155
155
155
155
155
174
174
174
174
-

120
120
140
140
155
155
155
155
155
155
155
155
155
174
174
174
174
174
174
174
174

(1) Value referred to the F, N versions.

WEIGHT kg

PN

MEI

bar

(1)

PUMP

PUMP

25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

8,4
8,8
9,2
9,7
10,9
11,3
11,7
12,1
12,5
13,3
14
14,4
15,2
16,4
17,2
18
18,9
20,7
21,5
22,3
23,1

13,2
13,6
14
16,4
20,5
20,9
23,1
23,5
23,9
24,7
27
27,5
28,2
34,4
35,2
36
36,8
42,6
43,4
44,2
45

D2

105
105
105
105
120
120
120
120
120
120
140
140
140
140
140
140
140
160
160
160
160

ELECTRIC

3sv-L-2p50-en_d_td

72

3SV
..L SERIES - L
OW NPSH
3SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

ISO 9906:2012 - Grade 3B

10

15

10

Q [Imp gpm]
Q
20[US gpm]

15

50Hz

3SV..L

260
800
31
29

220

LOW
NPSH

H [ft]

H [m]

33
240

700
27

200
25

600

180
23
160

21

500
19

140

400
120

16
14

100

13

300
12

11

80

10
200

09
60

08
07
06

40

100

05
04
03

0,2

60

Low

0,1

[%]

0
70

50

0,0
4

Standard

40
12

Standard

Low

0
0
0

2
20

3
40

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

73

4
60

Q [m /h]5
Q [l/min]
80

NPSH [ft]

kW/stage

06202_B_CH

NPSH [m]

Pp [kW]

20

LOW
NPSH

50Hz

5SV
..L SERIES - L
OW NPSH
5SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 5SV-L 2 poli 50 Hz


PUMP

MOTOR

TYPE

5SV03..L../D
5SV04..L../D
5SV05..L../D
5SV06..L../D
5SV07..L../D
5SV08..L../D
5SV09..L../D
5SV10..L../D
5SV11..L..
5SV12..L..
5SV13..L..
5SV14..L..
5SV15..L..
5SV16..L..
5SV18..L..
5SV21..L..
5SV23..L..
5SV25..L..
5SV28..L..
5SV30..L..
5SV33..L..

DIMENSIONS (mm)
L2

L1
kW

SIZE

0,75
0,75
1,1
1,1
1,5
1,5
1,5
1,5
2,2
2,2
2,2
2,2
2,2
3
3
3
4
4
4
5,5
5,5

80
80
80
80
90
90
90
90
90
90
90
90
90
100
100
100
112
112
112
132
132

303
328
353
378
413
438
463
488
513
538
563
588
613
648
698
773
823
873
948
1018
1093

D1

1~

3~

1~

3~

1~

3~

226
226
263
263
263
263
263
263
298
298
298
298
298
-

263
263
263
263
263
263
263
263
298
298
298
298
298
298
298
298
319
319
319
375
375

121
121
137
137
137
137
137
137
151
151
151
151
151
-

129
129
129
129
129
129
129
129
134
134
134
134
134
134
134
134
154
154
154
168
168

140
140
155
155
155
155
155
155
174
174
174
174
174
-

155
155
155
155
155
155
155
155
174
174
174
174
174
174
174
174
197
197
197
214
214

(1) Value referred to the F, N versions.

WEIGHT kg

PN

MEI

bar

(1)

PUMP

PUMP

25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

9,6
10
10,5
11
11,8
12,3
12,7
13,2
13,7
14,1
14,6
15
15,5
17
18
19,4
20,4
21,3
23
28,1
29,5

19,2
19,6
21,9
22,4
25
25,6
26
26,5
31,9
32,3
32,8
33,2
33,7
38
39
40,4
47
48
49,4
65,7
67,1

D2

120
120
120
120
140
140
140
140
140
140
140
140
140
160
160
160
160
160
160
300
300

ELECTRIC

5sv-L-2p50-en_d_td

74

5SV
..L SERIES - L
OW NPSH
5SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

10

15

10

ISO 9906:2012 - Grade 3B


20

20

25

Q30[Imp gpm]

30

Q [US gpm]

50Hz

5SV..L

260
800

240
30
220

28

LOW
NPSH

H [ft]

H [m]

33

700

200
25
600

180

23
21

160
140

500

18
400

16

120

15

100

13

14
300

12
11
10

80
09

200

08

60

07

40

05

06
100
04
03

0,6

0,2

60

Low

50

kW/stage

Standard

0,0
4

40
12

Standard

Low
0

0
0
0

2
20

4
40

8 Q [m /h]

60

80

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

75

100

120

Q [l/min]
140

NPSH [ft]

0,4

[%]

0
70

06203_B_CH

NPSH [m]

Pp [kW]

20

LOW
NPSH

50Hz

10SV
..L SERIES - L
OW NPSH
10SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 10SV-L 2 poli 50 Hz


PUMP

MOTOR

TYPE

DIMENSIONS (mm)
L2

L1
kW

SIZE

10SV03..L../D

1,5

90

10SV04..L..

2,2

10SV05..L..

2,2

10SV06..L..

D1

WEIGHT kg

PN

MEI

bar

(1)

PUMP

PUMP

D2

ELECTRIC

1~

3~

1~

3~

1~

3~

399

263

263

137

129

155

155

140

25

0,70

16,6

29,6

90

431

298

298

151

134

174

174

140

25

0,70

17,6

35,8

90

463

298

298

151

134

174

174

140

25

0,70

18,5

36,7

100

505

298

134

174

160

25

0,70

20,6

41,6

10SV07..L..

100

537

298

134

174

160

25

0,70

21,5

42,5

10SV08..L..

100

569

298

134

174

160

25

0,70

22,4

43,4

10SV09..L..

112

601

319

154

197

160

25

0,70

23,3

49,7

10SV10..L..

112

633

319

154

197

160

25

0,70

24,3

50,7

10SV11..L..

5,5

132

732

375

168

214

300

25

0,70

31,2

68,8

10SV13..L..

5,5

132

796

375

168

214

300

25

0,70

33,1

71

10SV15..L..

5,5

132

860

375

168

214

300

25

0,70

35

73

10SV17..L..

7,5

132

924

367

191

256

300

25

0,70

36,9

93

10SV18..L..

7,5

132

956

367

191

256

300

25

0,70

37,8

94

10SV20..L..

7,5

132

1020

367

191

256

300

25

0,70

39,6

96

10SV21..L..

11

160

1082

428

191

256

350

25

0,70

42,2

113

(1) Value referred to the F, N versions.

10sv-L-2p50-en_d_td

76

10SV
..L SERIES - L
OW NPSH
10SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

10

20

10

ISO 9906:2012 - Grade 3B

30

20

30

Q50[Imp gpm]

40
40

Q
60[US gpm]

50

50Hz

10SV..L

260
800
20

220

18

LOW
NPSH

240

H [ft]

H [m]

21

700

17

200

600

180

15

160

13

500

140
11

400

10

120

09
100

300

08
07

80
06

200

60

05
04

40

100

03

1,0

Low

0,5

Standard

kW/stage

40
12
Standard

2
Low

0
0
0

4
50

100

10
150

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

77

12

Q
14[m /h]

200

Q [l/min]
250

4
0

NPSH [ft]

0,0
4

60

[%]

0
80

06204_B_CH

NPSH [m]

Pp [kW]

20

LOW
NPSH

50Hz

15SV
..L SERIES - L
OW NPSH
15SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 15SV-L 2 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

PN

MEI

WEIGHT kg

TYPE

ELECTRIC

kW

SIZE

L1

L2

D1

D2

bar

(1)

PUMP

PUMP

15SV02..L..

100

419

298

134

174

160

25

0,70

17,6

36,6

15SV03..L..

112

467

319

154

197

160

25

0,70

19

45,4

15SV04..L..

112

515

319

154

197

160

25

0,70

20,3

46,8

15SV05..L..

5,5

132

630

375

168

214

300

25

0,70

27,6

65,2

15SV06..L..

5,5

132

678

375

168

214

300

25

0,70

28,9

67

15SV07..L..

7,5

132

726

367

191

256

300

25

0,70

30,2

86

15SV08..L..

7,5

132

774

367

191

256

300

25

0,70

31,5

88

15SV09..L..

11

160

852

428

191

256

350

25

0,70

35,7

106

15SV10..L..

11

160

900

428

191

256

350

25

0,70

37

108

15SV11..L..

11

160

948

428

191

256

350

25

0,70

38,3

109

15SV13..L..

11

160

1044

428

191

256

350

25

0,70

41

112

15SV15..L..

15

160

1140

494

240

313

350

25

0,70

43,7

146

15SV17..L..

15

160

1236

494

240

313

350

25

0,70

46,7

149

(1) Value referred to the F, N versions.

15sv-L-2p50-en_d_td

78

15SV
..L SERIES - L
OW NPSH
15SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

20

40

20

ISO 9906:2012 - Grade 3B

60

40

60

Q [Imp100
gpm]

80
80

Q [US120
gpm]

100

50Hz

15SV..L

260
800

240

H [ft]

15

220

LOW
NPSH

H [m]

17

700
200
13
600

180
11

160

500

10
140
09
120

400

08
07

100

300

06
80

05

60

200

04
03

40

02

100

0
80

Low

1,5

Standard

kW/stage

40
12

Standard

Low
0

0
0
0

6
100

10

12

14

16

200

18
300

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

79

20

22

24

Q [m /h]
26
28

400

Q [l/min]

NPSH [ft]

0,5
4

60

[%]

0
2,5

06205_B_CH

NPSH [m]

Pp [kW]

20

LOW
NPSH

50Hz

22SV
..L SERIES - L
OW NPSH
22SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 22SV-L 2 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

PN

MEI

WEIGHT kg

TYPE

ELECTRIC

kW

SIZE

L1

L2

D1

D2

bar

(1)

PUMP

22SV02..L..

100

419

298

134

174

160

25

0,70

18

39

22SV03..L..

112

467

319

154

197

160

25

0,70

19,4

46

22SV04..L..

5,5

132

582

375

168

214

300

25

0,70

25,4

63

22SV05..L..

5,5

132

630

375

168

214

300

25

0,70

26,7

65

22SV06..L..

7,5

132

678

367

191

256

300

25

0,70

28

84

22SV07..L..

11

160

756

428

191

256

350

25

0,70

31,8

102

22SV08..L..

11

160

804

428

191

256

350

25

0,70

33,1

104

22SV09..L..

11

160

852

428

191

256

350

25

0,70

34,4

105

22SV10..L..

11

160

900

428

191

256

350

25

0,70

35,8

107

22SV12..L..

15

160

996

494

240

313

350

25

0,70

38,4

141

22SV14..L..

15

160

1092

494

240

313

350

25

0,70

41,1

144

22SV17..L..

18,5

160

1236

494

240

313

350

25

0,70

45,1

156

(1) Value referred to the F, N versions.

PUMP

22sv-L-2p50-en_d_td

80

22SV
..L SERIES - L
OW NPSH
22SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

20

20

40
40

60
60

ISO 9906:2012 - Grade 3B


80

80

100

100

Q [Imp
120 gpm]

120

Q [US gpm]
140
900

17
800

240
220

14

LOW
NPSH

260

H [ft]

H [m]

280

50Hz

22SV..L

700

200
12

180
160

600

10

140

09

120

08

500

400

07
100
300

06
80

05

60

200

04
03

40

02

100

0
80

Low

NPSH [m]

60

kW/stage

Standard

40

6
16
12
8
4
0

Standard

4
2

Low

0
0
0

10
100

15
200

20
300

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

81

25
400

30

Q [m /h]
35

500

Q [l/min]

NPSH [ft]

[%]

0
3

06206_B_CH

Pp [kW]

20

LOW
NPSH

50Hz

33SV
..L SERIES - L
OW NPSH
33SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

MOTOR

DIMENSIONS (mm)

WEIGHT kg

18,5 160 1069 494 240 313 350 25

88 199

33SV2..L..

61

99

33SV8/1A..L..

22 180 1069 494 240 313 350 25

89 211

D1

D2

PN

5,5 132 584 375 168 214 300 16

TYPE

L1

L2

D1

D2

PN

PUMP

33SV8/2A..L..

SIZE

99

L2

kW

61

SIZE

33SV2/1A..L.. 5,5 132 584 375 168 214 300 16

L1

ELECTRIC
PUMP

PUMP

MEI (1)

WEIGHT kg
PUMP

TYPE

DIMENSIONS (mm)

ELECTRIC
PUMP

MOTOR

MEI (1)

PUMP

kW

DIMENSIONI E PESI SERIE 33SV-L 2 poli 50 Hz

65 121

33SV8..L..

22 180 1069 494 240 313 350 25

89 211

33SV3/1A..L.. 7,5 132 659 367 191 256 300 16

65 121

33SV9/2A..L..

22 180 1144 494 240 313 350 25

93 215
0,70

33SV3/2A..L.. 7,5 132 659 367 191 256 300 16


7,5 132 659 367 191 256 300 16

65 121

33SV9/1A..L..

22 180 1144 494 240 313 350 25

33SV4/2A..L..

11 160 769 428 191 256 350 16

73 144

33SV9..L..

22 180 1144 494 240 313 350 25

93 215

33SV4/1A..L..

11 160 769 428 191 256 350 16

73 144

33SV10/2A..L.. 30 200 1219 657 317 402 400 25

104 319

33SV4..L..

11 160 769 428 191 256 350 16

73 144

33SV10/1A..L.. 30 200 1219 657 317 402 400 25

104 319

33SV5/2A..L..

11 160 844 428 191 256 350 16

77 148

33SV10..L..

33SV5/1A..L..

15 160 844 494 240 313 350 16

77 179

33SV11/2A..L.. 30 200 1294 657 317 402 400 40

118 333

33SV5..L..

15 160 844 494 240 313 350 16

77 179

33SV11/1A..L.. 30 200 1294 657 317 402 400 40

118 333

33SV6/2A..L..

15 160 919 494 240 313 350 16

81 183

33SV11..L..

30 200 1294 657 317 402 400 40

118 333

33SV6/1A..L..

15 160 919 494 240 313 350 25

81 183

33SV12/2A..L.. 30 200 1369 657 317 402 400 40

122 337

33SV6..L..

15 160 919 494 240 313 350 25

81 183

33SV12/1A..L.. 30 200 1369 657 317 402 400 40

122 337

33SV7/2A..L.. 18,5 160 994 494 240 313 350 25

84 195

33SV12..L..

30 200 1369 657 317 402 400 40

122 337

33SV7/1A..L.. 18,5 160 994 494 240 313 350 25

84 195

33SV13/2A..L.. 30 200 1444 657 317 402 400 40

127 342

33SV7..L..

84 195

33SV13/1A..L.. 37 200 1444 657 317 402 400 40

127 357

18,5 160 994 494 240 313 350 25

0,70

33SV3..L..

30 200 1219 657 317 402 400 25

(1) Value referred to the G and N versions with PN 25 bar (2500 kPa). G and N versions with PN > 25 bar (2500 kPa).

82

93 215

104 319

33sv- L-2p50-en_c_td

33SV
..L SERIES - L
OW NPSH
33SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

0
0

20
20

40
40

60
60

ISO 9906:2012 - Grade 3B

80
80

100

100

Q
[Imp gpm]
140

120

120

gpm]
160 Q [US
180

140

13/1A
13/2A
12
12/1A
12/2A
11
11/1A
11/2A
10
10/1A
10/2A
9
9/1A
9/2A
8
8/1A
8/2A
7
7/1A
7/2A
6
6/1A
6/2A
5
5/1A
5/2A
4
4/1A
4/2A
3
3/1A
3/2A
2
2/1A

280
260
240
220
200
180
160
140
120
100
80
60
40

1000

900

LOW
NPSH

300

H [ft]

H [m]

320

800

700

600

500

400

300

200

100

P2 Low

60

P2 1

kW/stage

P2 /1

1
8

40
Standard

20
Low

10
0

0
0

5
100

10

15
200

20
300

25
400

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

83

30
500

35
600

Q 40
[m /h]
Q [l/min]
700

NPSH [ft]

[%]

0
80

06213_D_CH

NPSH [m]

Pp [kW]

20
0
4

50Hz

33SV..L

LOW
NPSH

50Hz

46SV
..L SERIES - L
OW NPSH
46SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

MOTOR

TYPE

DIMENSIONS (mm)

MOTOR

DIMENSIONS (mm)

46SV10..L..

37 200 1259 657 317 402 400 40

- 114 344

46SV2..L..

11 160 659 428 191 256 350 16

70 141

46SV11/2A..L.. 45 225 1334 746 384 455 450 40

- 126 482

SIZE

SIZE

D2

L1

L2

D1

D2 PN

ELECTRIC
PUMP

66 122

D1

WEIGHT kg
PUMP

7,5 132 624 367 191 256 300 16

MEI (1)

46SV2/1A..L..

L2

kW

TYPE

PN

L1

PUMP

PUMP

MEI (1)

WEIGHT kg
ELECTRIC
PUMP

PUMP

kW

DIMENSIONI E PESI SERIE 46SV-L 2 poli 50 Hz

46SV3/2A..L..

11 160 734 428 191 256 350 16

74 145

46SV11..L..

45 225 1334 746 384 455 450 40

- 126 482

46SV3..L..

15 160 734 494 240 313 350 16

74 176

46SV12/2A..L.. 45 225 1409 746 384 455 450 40

- 131 487

46SV12..L..

- 131 487

46SV4/2A..L..

15 160 809 494 240 313 350 16

78 180

46SV4..L..

15 160 809 494 240 313 350 16

78 180
82 193

46SV5..L..

82 193

18,5 160 884 494 240 313 350 16

0,70

46SV5/2A..L.. 18,5 160 884 494 240 313 350 16


46SV6/2A..L..

22 180 959 494 240 313 350 25

46SV6..L..

22 180 959 494 240 313 350 25

46SV7/2A..L..

30 200 1034 657 317 402 400 25

97 312

46SV7..L..

30 200 1034 657 317 402 400 25

97 312

45 225 1409 746 384 455 450 40

87 209
87 209

46SV8/2A..L..

30 200 1109 657 317 402 400 25

101 316

46SV8..L..

30 200 1109 657 317 402 400 25

101 316

46SV9/2A..L..

37 200 1184 657 317 402 400 25

105 335

46SV9..L..

37 200 1184 657 317 402 400 25

105 335

46SV10/2A..L.. 37 200 1259 657 317 402 400 40

- 114 344

(1) Value referred to the G and N versions with PN 25 bar (2500 kPa). G and N versions with PN > 25 bar (2500 kPa).

84

46sv-L-2p50-en c td

46SV
..L SERIES - L
OW NPSH
46SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

50

100

50

150

100

150

200
200

Q [Imp gpm]

250

Q [US gpm]
H [ft]

ISO 9906:2012 - Grade 3B

320
H [m]

12
12/2A

1000

LOW
NPSH

11

280

11/2A
10
10/2A

240

800

9
9/2A
8

200

8/2A
07
7/2A
6
6/2A

160

600

5
5/2A

120

400

4
4/2A
3
3/2A
2
2/1A

80

40

200

5
3

NPSH [m]

70
P2 Low

60

P2 1

kW/stage

P2 /1

1
6

50
20

Standard

Low
10

2
0

0
5

100

10
200

15

20
300

25
400

30

35

500

600

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

85

40
700

45

50
800

55 Q [m
60 /h] 65
Q900
[l/min] 1000

NPSH [ft]

[%]

0
80

06214_D_CH

Pp [kW]

50Hz

46SV..L

LOW
NPSH

50Hz

66SV
..L SERIES - L
OW NPSH
66SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 50 Hz, 2-POLE
AT

MOTOR

DIMENSIONS (mm)

WEIGHT kg

66SV8/2A..L..

45 225 1239 746 384 455 450 25

127 483

66SV2..L..

15 160 699 494 240 313 350 16

81

183

66SV8/1A..L..

45 225 1239 746 384 455 450 25

66SV3/2A..L..

15 160 789 494 240 313 350 16

86

188

66SV8..L..

45 225 1239 746 384 455 450 25

66SV3/1A..L.. 18,5 160 789 494 240 313 350 16

86

197

D2

PN

18,5 160 789 494 240 313 350 16

86

197

66SV4/2A..L..

22 180 879 494 240 313 350 16

93

215

66SV4/1A..L..

22 180 879 494 240 313 350 16

93

215

66SV4..L..

30 200 879 657 317 402 400 16

100 315

66SV5/2A..L..

30 200 969 657 317 402 400 16

66SV5/1A..L..

30 200 969 657 317 402 400 16

66SV5..L..

30 200 969 657 317 402 400 16

105 320

66SV6/2A..L..

30 200 1059 657 317 402 400 25

113 328

66SV6/1A..L..

37 200 1059 657 317 402 400 25

113 343

66SV6..L..

37 200 1059 657 317 402 400 25

113 343

66SV7/2A..L..

37 200 1149 657 317 402 400 25

118 348

66SV7/1A..L..

37 200 1149 657 317 402 400 25

118 348

66SV7..L..

45 225 1149 746 384 455 450 25

122 478

0,70

66SV3..L..

D1

L1

L2

D1

D2

PUMP

152

0,70

81

L2

SIZE

11 160 699 428 191 256 350 16

L1

kW

PN

66SV2/1A..L..

SIZE

TYPE

ELECTRIC
PUMP

PUMP

MEI (1)

WEIGHT kg
ELECTRIC
PUMP

TYPE

DIMENSIONS (mm)

PUMP

MOTOR

MEI (1)

PUMP

kW

DIMENSIONI E PESI SERIE 66SV-L 2 poli 50 Hz

127 483
127 483

105 320
105 320

(1) Value referred to the G and N versions.

66sv-L-2p50-en_c_td

86

66SV
..L SERIES - L
OW NPSH
66SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
2900 [rpm]

50
50

H [m]

240

100

150
150

200
200

300 Q [Imp gpm]

250

250

300

350

Q [US gpm]

8
8/1A
8/2A

800

7
7/1A
7/2A

700

6
6/1A
6/2A

600

5
5/1A
5/2A

500

4
4/1A
4/2A

400

3
3/1A
3/2A

300

2
2/1A

200

H [ft]

100

220
200
180

LOW
NPSH

ISO 9906:2012 - Grade 3B

160
140
120
100
80
60
40
100

P2 Low

60

P2 1
P2 /1

40
30
Standard

20

Low

10
0

0
0
0

10

15

200

20

25
400

30

35

40

45

600

50

800

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

87

55

60
1000

65

70

75

1200

[m /h]
80 Q85
90
Q [l/min]
1400

NPSH [ft]

kW/stage

[%]

0
80

06215_C_CH

NPSH [m]

Pp [kW]

20
0
10
8
6
4
2
10

50Hz

66SV..L

LOW
NPSH

60Hz

1SV
..L SERIES - L
OW NPSH
1SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 1SV-L 2 poli 60 Hz


PUMP

MOTOR

DIMENSIONS (mm)
L2

TYPE

1SV03..L..
1SV04..L..
1SV05..L..
1SV06..L..
1SV07..L../D
1SV08..L../D
1SV09..L../D
1SV10..L../D
1SV11..L../D
1SV12..L../D
1SV13..L../D
1SV15..L../D
1SV17..L../D
1SV18..L..
1SV20..L..
1SV22..L..
1SV24..L..
1SV26..L..
1SV28..L..

WEIGHT kg

D1

ELECTRIC

kW

SIZE

L1

1~

3~

1~

3~

1~

3~

D2

PUMP

PUMP

0,37
0,37
0,55
0,55
0,75
0,75
1,1
1,1
1,1
1,1
1,1
1,5
1,5
2,2
2,2
2,2
2,2
2,2
3

71
71
71
71
80
80
80
80
80
80
80
90
90
90
90
90
90
90
100

278
298
318
338
368
388
408
428
448
468
488
538
578
598
638
678
718
758
808

209
209
231
231
226
226
263
263
263
263
263
263
263
298
298
298
298
298
-

209
209
231
231
263
263
263
263
263
263
263
263
263
298
298
298
298
298
298

111
111
121
121
121
121
137
137
137
137
137
137
137
151
151
151
151
151
-

111
111
121
121
129
129
129
129
129
129
129
129
129
134
134
134
134
134
134

120
120
140
140
140
140
155
155
155
155
155
155
155
174
174
174
174
174
-

120
120
140
140
155
155
155
155
155
155
155
155
155
174
174
174
174
174
174

105
105
105
105
120
120
120
120
120
120
120
140
140
140
140
140
140
140
140

8,6
9
9,4
9,8
10,6
11
11,4
11,8
12,2
12,6
13
14,1
14,9
15,3
16,1
16,9
17,7
18,5
19,7

13,4
13,8
16,1
16,5
20,2
20,6
21
23,2
23,6
24
24,4
27
28
33,5
34,3
35
35,8
36,6
40,7

1sv-L-2p60-en_c_td

88

1SV
..L SERIES - L
OW NPSH
1SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

ISO 9906:2012 - Grade 3B

Q10[Imp gpm]

8
8

Q
12[US gpm]

10

60Hz

1SV..L

260
800

26
220

700

24
200

LOW
NPSH

H [ft]

H [m]

28
240

22
600

180

20

160

18

500
17

140

15
400

120

13
12

100

11

300

10
80

09
08
07
06
05

60
40

0,2

Low

0,1

Standard

kW/stage

20
Standard

4
2

Low

0
0
0

1
10

Q [m /h]3

2
20

30

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

89

40

Q [l/min]
50

16
12
8
4
0

NPSH [ft]

0,0
6

40

[%]

0
60

06207_B_CH

Pp [kW]

100

04
03

20

NPSH [m]

200

LOW
NPSH

60Hz

3SV
..L SERIES - L
OW NPSH
3SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 3SV-L 2 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)
L2

TYPE

WEIGHT kg

D1

ELECTRIC

kW

SIZE

L1

1~

3~

1~

3~

1~

3~

D2

PUMP

3SV03..L..

0,55

71

278

231

231

121

121

140

140

105

8,5

15,2

3SV04..L../D

0,75

80

308

226

263

121

129

140

155

120

9,3

18,9

3SV05..L../D

1,1

80

328

263

263

137

129

155

155

120

9,7

21,1

3SV06..L../D

1,1

80

348

263

263

137

129

155

155

120

10,1

21,5

3SV07..L../D

1,1

80

368

263

263

137

129

155

155

140

10,5

21,9

3SV08..L../D

1,5

90

398

263

263

137

129

155

155

140

11,2

24,5

3SV09..L../D

1,5

90

418

263

263

137

129

155

155

140

11,6

25

3SV10..L..

2,2

90

438

298

298

151

134

174

174

140

12

30,2

3SV11..L..

2,2

90

458

298

298

151

134

174

174

140

12,4

30,6

3SV12..L..

2,2

90

478

298

298

151

134

174

174

140

12,8

30,9

3SV13..L..

2,2

90

498

298

298

151

134

174

174

140

13,2

31,3

3SV14..L..

2,2

90

518

298

298

151

134

174

174

140

13,6

31,7

3SV15..L..

100

548

298

134

174

160

14,4

35,4

3SV17..L..

100

588

298

134

174

160

15,2

36,2

3SV19..L..

100

628

298

134

174

160

16

37

3SV21..L..

112

668

319

154

197

160

16,8

43,2

3SV23..L..

112

708

319

154

197

160

17,6

44

PUMP

3sv-L-2p60-en_c_td

90

3SV
..L SERIES - L
OW NPSH
3SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

ISO 9906:2012 - Grade 3B

10

Q20[Imp gpm]

15

10

15

Q [US
25 gpm]

20

60Hz

3SV..L

260
800

240
21
220

LOW
NPSH

H [ft]

H [m]

23

700
19

200
17

600

180
15

160

500

14
13

140
12
120

400
11

10
100

09

300

08
80

07
200

06
60
05
04

40

100
03

0,4

50

Standard

kW/stage

0,0
6

60

Low

40
16
12
8
4
0

Standard

4
2

Low

0
0
0

2
20

3
40

4
60

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

91

5
80

Q [m /h]6
Q [l/min]
100

NPSH [ft]

0,2

[%]

0
70

06208_B_CH

NPSH [m]

Pp [kW]

20

LOW
NPSH

60Hz

5SV
..L SERIES - L
OW NPSH
5SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 5SV-L 2 poli 60 Hz


PUMP

MOTOR

DIMENSIONS (mm)
L2

TYPE

5SV03..L../D
5SV04..L../D
5SV05..L../D
5SV06..L..
5SV07..L..
5SV08..L..
5SV09..L..
5SV10..L..
5SV11..L..
5SV12..L..
5SV13..L..
5SV14..L..
5SV15..L..
5SV16..L..
5SV17..L..
5SV19..L..
5SV21..L..
5SV23..L..

WEIGHT kg

D1

ELECTRIC

kW

SIZE

L1

1~

3~

1~

3~

1~

3~

D2

PUMP

PUMP

1,1
1,5
1,5
2,2
2,2
2,2
3
3
3
4
4
4
4
4
5,5
5,5
5,5
7,5

80
90
90
90
90
90
100
100
100
112
112
112
112
112
132
132
132
132

303
338
363
388
413
438
473
498
523
548
573
598
623
648
693
743
793
843

263
263
263
298
298
298
-

263
263
263
298
298
298
298
298
298
319
319
319
319
319
375
375
375
367

137
137
137
151
151
151
-

129
129
129
134
134
134
134
134
134
154
154
154
154
154
168
168
168
191

155
155
155
174
174
174
-

155
155
155
174
174
174
174
174
174
197
197
197
197
197
214
214
214
256

120
140
140
140
140
140
160
160
160
160
160
160
160
160
300
300
300
300

9,4
10,1
10,6
11,1
11,6
12,1
13
13,5
13,9
14,4
14,9
15,3
15,8
16,3
20,7
21,6
22,6
23

20,8
23,5
24
29,3
29,8
30,2
34
34,4
34,9
40,8
41,2
41,7
42,2
42,6
58,2
59,2
60,1
79

5sv-L-2p60-en_c_td

92

5SV
..L SERIES - L
OW NPSH
5SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

10

ISO 9906:2012 - Grade 3B

20

10

Q [Imp gpm]
40

30

20

30

40

Q [US gpm]
900

23
800

240

LOW
NPSH

260

H [ft]

H [m]

280

60Hz

5SV..L

21

220

700

19

200
17
180

16

160

14

600

15
500
13

140

12
400

11

120

10
09

100

300

08
80

07
06

200
05

60
04
40

100

03

1,0

60

kW/stage

0,0
NPSH [m]

Low
Standard

40

Standard

Low

0
0
0

50

100

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

93

10 Q [m3/h]

8
150

Q [l/min]

16
12
8
4
0

NPSH [ft]

0,5

[%]

0
80

06209_B_CH

Pp [kW]

20

LOW
NPSH

60Hz

10SV
..L SERIES - L
OW NPSH
10SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 10SV-L 2 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)
L2

TYPE

WEIGHT kg

D1

ELECTRIC

kW

SIZE

L1

1~

3~

1~

3~

1~

3~

D2

PUMP

PUMP

10SV03..L..

100

409

298

134

174

160

17,5

38,5

10SV04..L..

100

441

298

134

174

160

18,4

39,4

10SV05..L..

112

473

319

154

197

160

19,3

45,7

10SV06..L..

5,5

132

572

375

214

214

300

25

62,6

10SV07..L..

5,5

132

604

375

168

214

300

26

63,5

10SV08..L..

5,5

132

636

375

168

214

300

26,9

64,5

10SV09..L..

7,5

132

668

367

191

256

300

27,9

83,6

10SV10..L..

7,5

132

700

367

191

256

300

28,8

84,5

10SV11..L..

7,5

132

732

367

191

256

300

29,7

85,5

10SV13..L..

11

160

826

428

191

256

350

34,4

105

10SV15..L..

11

160

890

428

191

256

350

36,3

107

10sv-L-2p60-en_c_td

94

10SV
..L SERIES - L
OW NPSH
10SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

10

20

30

20

ISO 9906:2012 - Grade 3B


40

40

50

Q60[Imp gpm]

60

Q [US gpm]
900

15
800

240

LOW
NPSH

260

H [ft]

H [m]

280

60Hz

10SV..L

13
220

700

200
11
180

600

10

160

09

140

08

120

07

500

400

06

100

300
05

80

04

200

60
03
40

100

Low

60

0,9
kW/stage

0,3
4

Standard

40
12

Standard

2
Low
0

4
0

0
0

4
50

6
100

10
150

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

95

12
200

16 Q [m /h]
18

14
250

Q [l/min]
300

NPSH [ft]

1,5

[%]

0
80

06210_B_CH

NPSH [m]

Pp [kW]

20

LOW
NPSH

60Hz

15SV
..L SERIES - L
OW NPSH
15SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 15SV-L 2 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

ELECTRIC

kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

15SV02..L..

112

419

319

154

174

160

18

44,4

15SV03..L..

5,5

132

534

375

168

214

300

24

61,6

15SV04..L..

7,5

132

582

367

191

256

300

25,2

81

15SV05..L..

11

160

660

428

191

256

350

29,3

100

15SV06..L..

11

160

708

428

191

256

350

30,6

101

15SV07..L..

11

160

756

428

191

256

350

32

103

15SV08..L..

15

160

804

494

240

313

350

33,3

136

15SV09..L..

15

160

852

494

240

313

350

34,6

137

15SV10..L..

15

160

900

494

240

313

350

36

138

15SV11..L..

18,5

160

948

494

240

313

350

37,3

148

15SV12..L..

18,5

160

996

494

240

313

350

38,6

150

15sv-L-2p60-en_b_td

96

15SV
..L SERIES - L
OW NPSH
15SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

20

40

20

40

60
60

ISO 9906:2012 - Grade 3B


80

80

100

100

Q [Imp
120 gpm]

120

Q [US gpm]
140
900

12
800

240

LOW
NPSH

260

H [ft]

H [m]

280

60Hz

15SV..L

11
220

700

10
200
09

600

180
08
160

500

07
140
06

120

400

05

100

300
04

80
60

03

40

02

200

100

0
80

2,5

Standard

kW/stage

40

6
16
12
8
4
0

Standard

4
2

Low

0
0
0

10
100

15
200

20
300

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

97

25
400

30

Q [m /h]
35

500

Q [l/min]

NPSH [ft]

1,5
NPSH [m]

60

Low

[%]

0
3,5

06211_B_CH

Pp [kW]

20

LOW
NPSH

60Hz

22SV
..L SERIES - L
OW NPSH
22SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 22SV-L 2 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

ELECTRIC

kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

22SV02..L..

5,5

132

486

375

168

214

300

23

61

22SV03..L..

7,5

132

534

367

191

256

300

24,3

80

22SV04..L..

11

160

612

428

191

256

350

28,5

99

22SV05..L..

11

160

660

428

191

256

350

29,8

100

22SV06..L..

15

160

708

494

240

313

350

31,1

133

22SV07..L..

15

160

756

494

240

313

350

32,4

135

22SV08..L..

15

160

804

494

240

313

350

33,8

136

22SV09..L..

18,5

160

852

494

240

313

350

35,1

146

22SV10..L..

22

180

900

494

240

313

350

36,4

158

22sv-L-2p60-en_b_td

98

22SV
..L SERIES - L
OW NPSH
22SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

20

20

40
40

60
60

ISO 9906:2012 - Grade 3B

80
80

100

100

120

120

140

Q [Imp
140gpm]
Q [US gpm]
160

60Hz

22SV..L

10
700

200

09

180

08

160

LOW
NPSH

220

H [ft]

H [m]

240

600

07

500

140
06
400

120
05
100

300

04
80
03

200

60
02

40

100

0
80

Low

60

Standard

kW/stage

1
10

40
30
Standard

20
Low

0
0
0

5
100

10

15
200

20
300

25
400

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

99

30
500

35

10
0
3
Q [m40
/h]

600 Q [l/min]

NPSH [ft]

[%]

0
4

06212_B_CH

NPSH [m]

Pp [kW]

20

LOW
NPSH

60Hz

33SV
..L SERIES - L
OW NPSH
33SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 33SV-L 2 poli 60 Hz


WEIGHT kg

PUMP

MOTOR

DIMENSIONS (mm)

WEIGHT kg

SIZE

7,5 132 584 367 256 300 191 16

61

117

33SV8/2A..L..

37

200 1069 657 402 400 317 40 101

33SV2..L..

11

160 619 428 256 350 191 16

65

136

33SV8/1A..L..

37

200 1069 657 402 400 317 40 101

331

33SV3/2A..L..

11

160 694 428 256 350 191 16

69

140

33SV8..L..

37

200 1069 657 402 400 317 40 101

331

33SV3/1A..L..

15

160 694 494 313 350 240 16

69

171

kW

SIZE

L1

L2

D1

D2

PN

33SV3..L..

15

160 694 494 313 350 240 16

69

171

33SV4/2A..L..

15

160 769 494 313 350 240 16

73

175

33SV4/1A..L.. 18,5 160 769 494 313 350 240 25

73

184

33SV4..L..

18,5 160 769 494 313 350 240 25

73

184

33SV5/2A..L.. 18,5 160 844 494 313 350 240 25

77

188

33SV5/1A..L..

22

180 844 494 313 350 240 25

78

200

33SV5..L..

22

180 844 494 313 350 240 25

78

200

33SV6/2A..L..

30

200 919 657 402 400 317 25

89

304

33SV6/1A..L..

30

200 919 657 402 400 317 25

89

304

33SV6..L..

30

200 919 657 402 400 317 25

89

304

33SV7/2A..L..

30

200 994 657 402 400 317 25

92

307

33SV7/1A..L..

30

200 994 657 402 400 317 25

92

307

33SV7..L..

30

200 994 657 402 400 317 25

92

307

PUMP

kW

33SV2/1A..L..

TYPE

TYPE
L1

L2

D1

D2

PN

ELECTRIC
PUMP

DIMENSIONS (mm)

ELECTRIC
PUMP

MOTOR

PUMP

PUMP

331

33sv-L-2p60-en_b_td

100

33SV
..L SERIES - L
OW NPSH
33SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

50

ISO 9906:2012 - Grade 3B

100

50

150

100

Q [Imp gpm]
Q [US gpm]
200

150

260
240
220
200
180
160

8
8/1A
8/2A

900

7
7/1A
7/2A

800

6
6/1A
6/2A

700

5
5/1A
5/2A

600

500

4
4/1A
4/2A

140

400

120
3
3/1A
3/2A

100
80

300

2
2/1A

60

LOW
NPSH

280

H [ft]

H [m]

300

200

40
100
20

60

P2 1

kW/stage

P2 /1

1
12

40

Standard

30
20
10
0

Low

4
0
0
0

8
100

12
200

16

20
300

24

28

400

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

101

32
500

36
600

44 Q [m
48 /h]

40
700

Q 800
[l/min]

NPSH [ft]

NPSH [m]

P2 Low

[%]

0
80

06216_C_CH

Pp [kW]

60Hz

33SV..L

LOW
NPSH

60Hz

46SV
..L SERIES - L
OW NPSH
46SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 46SV-L 2 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

46SV2/1A..L..

15

160

659

494

313

350

240

16

70

172

46SV2..L..

15

160

659

494

313

350

240

16

70

172

46SV3/2A..L..

18,5

160

734

494

313

350

240

16

74

185

46SV3/1A..L..

22

180

734

494

313

350

240

16

74

196

46SV3..L..

22

180

734

494

313

350

240

16

74

196

46SV4/2A..L..

30

200

809

657

402

400

317

16

86

301

46SV4/1A..L..

30

200

809

657

402

400

317

16

86

301

46SV4..L..

30

200

809

657

402

400

317

16

86

301

46SV5/2A..L..

30

200

884

657

402

400

317

25

90

305

46SV5/1A..L..

37

200

884

657

402

400

317

25

90

320

46SV5..L..

37

200

884

657

402

400

317

25

90

320

46SV6/2A..L..

37

200

959

657

402

400

317

25

94

324

46SV6/1A..L..

45

225

959

746

402

400

317

25

98

454

46SV6..L..

45

225

959

746

402

400

317

25

98

454

46SV7/2A..L..

45

225

1034

746

455

450

384

40

105

461

46SV7/1A..L..

45

225

1034

746

455

450

384

40

105

461

46SV7..L..

45

225

1034

746

455

450

384

40

105

461
46sv-L-2p60-en b td

102

46SV
..L SERIES - L
OW NPSH
46SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

50

100

50

ISO 9906:2012 - Grade 3B

150

100

150

Q
[Imp gpm]
250

200
200

Q [US gpm]
300

250

900

H [ft]

7
7/1A
7/2A

260
240

800

LOW
NPSH

H [m]

280

220
200
180
160

6/1A
6/2A

700

5
5/1A
5/2A

600

500

4
4/1A
4/2A

140

400

120
100
80
60

3
3/1A
3/2A

300

2
2/1A

200

40
100
20

9
7

NPSH [m]

70

P2 Low

P2 1

kW/stage

60

P2 /1

3
8

[%]

0
80

50
Standard

20

10

NPSH [ft]

Pp [kW]

10
200

15

20

25
400

30

35

40

600

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

103

45

50
800

55

60
1000

65

0
3
[m /h]
70 Q75
Q [l/min]
1200

06217_C_CH

Low
0

60Hz

46SV..L

LOW
NPSH

60Hz

66SV
..L SERIES - L
OW NPSH
66SV..L
LOW
DIMENSIONS AND WEIGHTS A
T 60 Hz, 2-POLE
AT

DIMENSIONI E PESI SERIE 66SV-L 2 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

18,5

160

699

494

313

350

240

16

81

192

66SV2..L..

22

160

699

494

313

350

240

16

81

203

66SV3/2A..L..

30

200

789

657

402

400

317

16

94

309

66SV3/1A..L..

30

200

789

657

402

400

317

16

94

309

66SV2/1A..L..

66SV3..L..

37

200

789

657

402

400

317

16

94

324

66SV4/2A..L..

37

200

879

657

402

400

317

16

100

330

66SV4/1A..L..

37

200

879

657

402

400

317

25

102

332

66SV4..L..

45

225

879

746

455

450

384

25

106

462

66SV5/2A..L..

45

225

969

746

455

450

384

25

111

467

66sv-L-2p60-en_b_td

104

66SV
..L SERIES - L
OW NPSH
66SV..L
LOW
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 2-POLE
OPERATING
CHARACTERISTICS
AT
3500 [rpm]

100

100

200

ISO 9906:2012 - Grade 3B


400 Q [Imp gpm]

300

200

300

Q [US gpm]
500

400

H [ft]

220

700
200

LOW
NPSH

H [m]

240

5/2A
600

180

4
4/1A

160

4/2A

140

500

3
3/1A

120

400

3/2A
100

300

2/1A

80

200

60
40

100

70

P2 Low

kW/stage

60

P2 1
P2 /1

50
40

Standard

10

Low

5
0
0
0

20

40
500

60
1000

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

105

[%]

0
80

80
1500

100

20
0
Q [m3/h]

Q [l/min] 2000

NPSH [ft]

0
20
16
12
8
4
15

06218_C_CH

Pp [kW]

20

NPSH [m]

60Hz

66SV..L

106

LOW
NPSH
60Hz

107

HIGH
TEMPERA
TU
RE
TEMPERATU
TURE

HIGH
TEMPERATURE
...150C
(50/60 Hz)

ErP 2009/125/EC (50 Hz)


e-SV SERIES - HIGH TEMPERA
TURE (...150C)
TEMPERATURE
50/60 Hz

HIGH
RE
TU
TEMPERA
TURE
TEMPERATU

Background and context


In industrial applications pumps often have to deal with
liquids at high temperatures in order to optimise
performance for each production process. In these
applications, pumps frequently need to be protected
from excessive temperatures for the purpose of
maintaining high performance levels. Thats why Lowara
has developed the e-SVTM High Temperature series:
this sturdy pump integrates a mechanical seal
normalised with suitable materials for pumping liquids
at high temperatures.

Benefits of the e-SVTM High


Temperature 150C series

Long-term mechanical seal performance


performance::
Thanks to the special design of its housing, the seal is
protected from the stress caused by high temperatures
by means of a natural lubrication process which is
triggered by the pumped liquid itself. Furthermore, the
balanced mechanical seal and the high quality of the
elastomers used in the e-SVTM High Temperature series
assure excellent long-term performance, even in the
harshest operating conditions.

Special features / benefits

Identification code

Special configurations

- Special design of the mechanical seal


chamber for high temperature applications.
- Standard mechanical seal (EN12756) fitted on all
models. Easy to replace without removing
the motor from 5,5 kW up.
Solidity
Solidity: e-SVTM High Temperature pumps are hard- Hard metal intermediate bush support
wearing thanks to the hard metal bush supports which
(tungsten carbide) to increase the duration and
can withstand high temperature applications up to
capability of operating in extreme conditions,
150C and pressure values up to 25 bar (see the
available on all sizes.
pressure-temperature diagram).
- Balanced impeller design to reduce axial thrust
and extend the lifetime of standard motor bearings.
Easy and cost-effective maintenance
maintenance:
- IE2 or IE3 standard motors
motors, three-phase, 2-pole,
the mechanical seal installed in e-SVTM High Temperature from 0,75 kW to 55 kW with fixed bearing to
pumps is a standard balanced mechanical seal
endure extreme thrusts without limiting
(EN12756) which makes it cheap and easy to replace.
inlet pressure
pressure.
e-SVTM High Temperature models are identified by the
H in the standard identification code of the eletter H
SVTM product range.
Available in the following versions:
H in AISI 304 (for 1-22SV).
FH
H in AISI 304/Cast iron (for 33-125SV).
GH
H in AISI 316 (for all versions).
NH

A wide range of configurations is available for e-SVTM


High Temperature pumps:
- Materials used: see the Materials section.
- Options for mechanical seals and gaskets:
see the mechanical seals and gaskets section.
- Options for motors and configuration:
see the motors section.

H015T
Example: 3SV13FH
H = High Temperature.

108

e-SV SERIES - HIGH TEMPERA


TURE (...150C)
TEMPERATURE
50/60 Hz
Technical specifications - Design

1: Special design of the mechanical seal chamber,


assuring adequate lubrication triggered by the
pumped liquid, thus extending product lifetime.

HIGH
TEMPERA
TU
RE
TEMPERATU
TURE

2: Balanced mechanical seal in order to withstand high


pressures and temperatures.

Operating characteristics
For the hydraulic performances, please refer to the
standard catalogue of e-SVTM.

Route of pumped liquid.

109

HIGH
RE
TU
TEMPERA
TURE
TEMPERATU

e-SV SERIES - HIGH TEMPERA


TURE (...150C) 50/60 Hz
TEMPERATURE
ELECTRIC PUMP CROS
S SECTION AND MAIN COMPONENTS
CROSS

1, 3, 5SV SERIES
10, 15, 22SV SERIES 5,5 kW
10, 15, 22SV SERIES 4 kW
MATERIALI 1-22 SV VERSIONI F e N H 150
H VERSIONS
REF.

FH VERSION

NAME
MATERIAL

N.

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

NH VERSION

REFERENCE STANDARDS
EUROPE

Pump body
Impeller
Diffuser
Outer sleeve
Shaft
Adapter
Base
Coupling
Seal plate
Mechanical seal
Elastomers
Coupling protection
Shaft sleeve and bushing
Fill / drain plugs
Tie rods
Wear ring
Seal housing
Final Diffuser

USA

Stainless steel
1.4301
Stainless steel
1.4301
Stainless steel
1.4301
Stainless steel
1.4301
Stainless steel
1.4301
Cast iron
EN-JL1040
Aluminium
AC46100
Aluminium
AC46100
Stainless steel
1.4301
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel
1.4301
Tungsten carbide
Stainless steel
1.4301
Galvanized steel 1.0765
Technopolymer PPS
Stainless steel
1.4308
Stainless steel
1.4404

AISI 304
AISI 304
AISI 304
AISI 304
AISI 304
ASTM Class 35
AISI 304

AISI 304
AISI 304

AISI 304
AISI 316L

MATERIAL

REFERENCE STANDARDS
EUROPE

Stainless steel
1.4404
Stainless steel
1.4404
Stainless steel
1.4404
Stainless steel
1.4404
Stainless steel
1.4401
Cast iron
EN-JL1040
Aluminium
AC46100
Aluminium
AC46100
Stainless steel
1.4404
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel
1.4301
Tungsten carbide
Stainless steel
1.4401
Stainless steel
1.4057
Technopolymer PPS
Stainless steel
1.4408
Stainless steel
1.4404

USA

AISI 316L
AISI 316L
AISI 316L
AISI 316L
AISI 316
ASTM Class 35
AISI 316L

AISI 304
AISI 316
AISI 431
AISI 316
AISI 316L
1-22sv-FH_NH-en_a_tm

110

HIGH
TEMPERA
TU
RE
TEMPERATU
TURE

e-SV SERIES - HIGH TEMPERA


TURE (...150C) 50/60 Hz
TEMPERATURE
ELECTRIC PUMP CROS
S SECTION AND MAIN COMPONENTS
CROSS

33, 46, 66, 92SV SERIES

125SV SERIES

MATERIALI 33-125 SV VERSIONI G e N H 150

H VERSIONS
REF.

GH VERSION

NAME
MATERIAL

N.

1
1A
1A
2
3
2-3
4
5

Pump body
Lower support 33-92SV
Lower support 125SV
Impeller 33-92SV
Diffuser 33-92SV
Impeller, Diffuser 125SV
Outer sleeve
Shaft
Adapter
6
Adapter ( for 55kW )
7
Wear ring
Coupling
8
Coupling ( for 55kW )
9-9A Upper head, Seal housing
10 Mechanical seal
11 Elastomers
12 Coupling protection
13 Shaft sleeve and bushing
14 Bushing for diffuser
15 Fill / drain / air plugs
16 Tie rods
17 Adapter ring
18 Final Diffuser
19 Conveyor

NH VERSION

REFERENCE STANDARDS
EUROPE

USA

Cast iron
EN-JL1040 ASTM Class 35
Cast iron
EN-JL1040 ASTM Class 35
Stainless steel 1.4308
AISI 304
Stainless steel 1.4404
AISI 316L
Stainless steel 1.4301
AISI 304
Stainless steel 1.4308
AISI 304
Stainless steel 1.4301
AISI 304
Stainless steel 1.4057
AISI 431
Cast iron
EN-JL1030 ASTM Class 25
Cast iron
EN-JS1050 ASTM A 536 80-55-06
Technopolymer PPS
Cast iron
EN-JL1030 ASTM Class 25
Cast iron
EN-JS1050 ASTM A 536 80-55-06
Cast iron
EN-JL1040 ASTM Class 35
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel 1.4301
AISI 304
Tungsten carbide
Carbon
Stainless steel 1.4401
AISI 316
Galvaniz. steel 1.0765
Stainless steel 1.4308
AISI 304
Stainless steel 1.4404
AISI 316L
Stainless steel 1.4401
AISI 316

MATERIAL

REFERENCE STANDARDS
EUROPE

USA

Stainless steel 1.4408


AISI 316
Stainless steel 1.4408
AISI 316
Stainless steel 1.4408
AISI 316
Stainless steel 1.4404
AISI 316L
Stainless steel 1.4404
AISI 316L
Stainless steel 1.4408
AISI 316
Stainless steel 1.4404
AISI 316L
Stainless steel 1.4462
UNS S 31803
Cast iron
EN-JL1030 ASTM Class 25
Cast iron
EN-JS1050 ASTM A 536 80-55-06
Technopolymer PPS
Cast iron
EN-JL1030 ASTM Class 25
Cast iron
EN-JS1050 ASTM A 536 80-55-06
Stainless steel 1.4408
AISI 316
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel 1.4301
AISI 304
Tungsten carbide
Carbon
Stainless steel 1.4401
AISI 316
Stainless steel 1.4057
AISI 431
Stainless steel 1.4408
AISI 316
Stainless steel 1.4404
AISI 316L
Stainless steel 1.4401
AISI 316
33-125sv-GH_NH-en_a_tm

111

e-SV SERIES - HIGH TEMPERA


TURE (...150C) 50/60 Hz
TEMPERATURE
BALANCED MECHANICAL SEALS, ACCORDING TO EN 12756

HIGH
RE
TU
TEMPERA
TURE
TEMPERATU

1, 3, 5, 10, 15, 22SV

33, 46, 66, 92, 125SV

TENUTA MECCANICA SV MATERIALI VERSIONI ALTA TEMPERATURA

LIST OF MA
TERIALS
MATERIALS
POSITION 1 - 2

POSITION 3

Q 1 : Silicon Carbide
A : Carbon metal-impregned

E
V

POSITION 4 - 5
G

: EPDM
: FPM

: AISI 316

TENUTA MECCANICA SV COMBINAZIONI VERSIONI ALTA TEMPERATURA

TYPE OF SEAL
TYPE

ROTATING PART

STATIONARY PART

Q1 A E G G

Q1

Q1 A V G G
*Q 1 Q1 V G G

Q1
Q1

POSITION
3
ELASTOMERS

TEMPERATURE
4

SPRINGS

OTHER COMPONENTS

MECHANICAL SEAL FOR USE WITH WATER


A
E
G
OTHER TYPES OF AVAILABLE MECHANICAL SEAL
A
V
G
Q1
V
G

* Versions with anti-rotation lock pin of the fixed part.

sv-at_ten-mec-en_a_tm

( C )

-30 +150

G
G

-10 +150
-10 +150
sv-at_tipi-ten-mec-en_a_tc

PRES
SURE/TEMPERA
TURE APPLICA
TION LIMITS FOR COMPLETE PUMP
PRESSURE/TEMPERA
SURE/TEMPERATURE
APPLICATION
(APPLICABLE WITH ANY OF THE SEALS LISTED ABO
VE)
ABOVE)

112

e-SV SERIES - HIGH TEMPERA


TURE (...150C)
TEMPERATURE
DIMENSIONS A
T 50/60 Hz
AT

DIMENSIONI SERIE 1-22 SV-H 2 poli


AVAILABLE STAGES

FLANGES

TYPE

DIMENSIONS
(mm)
LH

50Hz

60Hz

PN

1SV-H

*L1+20

0237

0226

25

3SV-H

*L1+20

0231

0221

25

5SV-H

*L1+25

0230

0221

25

10SV-H

*L1=LH

0120

0113

25

15SV-H

*L1=LH

0115

0111

25

22SV-H

*L1=LH

0114

0110

25

*L1,*L2 = Standard product dimension, see e-SV catalogue.


1-22sv-h-en_a_td

1, 3, 5, 10, 15, 22SV SERIES

DIMENSIONI SERIE 33-125 SV-H 2 po


PUMP

AVAILABLE STAGES

FLANGES

TYPE

DIMENSIONS
(mm)
LH

50Hz

60Hz

PN

33SV-H

*L1=LH

1/1A9

1/1A6

25

46SV-H

*L1=LH

1/1A9

1/1A6

25

66SV-H

*L1=LH

1/1A7

1/1A5

25

92SV-H

*L1=LH

125SV-H

*L1=LH

1/1A7/2A 1/1A4/2A
18/2A

15/5A

25
25

*L1,*L2 = Standard product dimension, see e-SV catalogue.


33-125sv-h-en_a_td

33, 46, 66, 92, 125SV SERIES

113

HIGH
TEMPERA
TU
RE
TEMPERATU
TURE

PUMP

e-SV SERIES - HIGH TEMPERA


TURE (...150C)
TEMPERATURE
TABELLA DI PRESTAZI TABELLA DI PRESTAZIONI IDRAULICHE SERIE ALTA TEMPER
HYDRA
ULIC PERFORMANCE T
ABLE A
T 50 Hz, 2 POLES
HYDRAULIC
TABLE
AT
PUMP

RATED

TYPE

POWER

MEI

PUMP

RATED

TYPE

POWER

MEI

PUMP

RATED

TYPE

POWER

MEI

Q = DELIVERY
H = HEAD

1SV02
1SV03
1SV04
1SV05
1SV06
1SV07
1SV08
1SV09
1SV10
1SV11
1SV12
1SV13
1SV15
1SV17
1SV19
1SV22
1SV25
1SV27
1SV30
1SV32
1SV34
1SV37
3SV02
3SV03
3SV04
3SV05
3SV06
3SV07
3SV08
3SV09
3SV10
3SV11
3SV12
3SV13
3SV14
3SV16
3SV19
3SV21
3SV23
3SV25
3SV27
3SV29
3SV31
5SV02
5SV03
5SV04
5SV05
5SV06
5SV07
5SV08
5SV09
5SV10
5SV11
5SV12
5SV13
5SV14
5SV15
5SV16
5SV18
5SV21
5SV23
5SV25
5SV28
5SV30

kW

HP

(1)

0,37
0,37
0,37
0,37
0,37
0,37
0,55
0,55
0,55
0,55
0,75
0,75
0,75
1,1
1,1
1,1
1,5
1,5
1,5
2,2
2,2
2,2
0,37
0,37
0,37
0,55
0,55
0,75
0,75
1,1
1,1
1,1
1,1
1,5
1,5
1,5
2,2
2,2
2,2
2,2
3
3
3
0,37
0,55
0,55
0,75
1,1
1,1
1,1
1,5
1,5
1,5
2,2
2,2
2,2
2,2
2,2
3
3
4
4
4
5,5

0,5
0,5
0,5
0,5
0,5
0,5
0,75
0,75
0,75
0,75
1
1
1
1,5
1,5
1,5
2
2
2
3
3
3
0,5
0,5
0,5
0,75
0,75
1
1
1,5
1,5
1,5
1,5
2
2
2
3
3
3
3
4
4
4
0,5
0,75
0,75
1
1,5
1,5
1,5
2
2
2
3
3
3
3
3
4
4
5,5
5,5
5,5
7,5

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

10SV01
10SV02
10SV03
10SV04
10SV05
10SV06
10SV07
10SV08
10SV09
10SV10
10SV11
10SV13
10SV15
10SV17
10SV18
10SV20
15SV01
15SV02
15SV03
15SV04
15SV05
15SV06
15SV07
15SV08
15SV09
15SV10
15SV11
15SV13
15SV15
22SV01
22SV02
22SV03
22SV04
22SV05
22SV06
22SV07
22SV08
22SV09
22SV10
22SV12
22SV14
33SV1/1A
33SV1
33SV2/2A
33SV2/1A
33SV2
33SV3/2A
33SV3/1A
33SV3
33SV4/2A
33SV4/1A
33SV4
33SV5/2A
33SV5/1A
33SV5
33SV6/2A
33SV6/1A
33SV6
33SV7/2A
33SV7/1A
33SV7
33SV8/2A
33SV8/1A
33SV8
33SV9/2A
33SV9/1A
33SV9

kW

HP

(1)

0,75
0,75
1,1
1,5
2,2
2,2
3
3
4
4
4
5,5
5,5
7,5
7,5
7,5
1,1
2,2
3
4
4
5,5
5,5
7,5
7,5
11
11
11
15
1,1
2,2
3
4
5,5
7,5
7,5
11
11
11
15
15
2,2
3
4
4
5,5
5,5
7,5
7,5
7,5
11
11
11
11
15
15
15
15
15
18,5
18,5
18,5
18,5
22
22
22
22

1
1
1,5
2
3
3
4
4
5,5
5,5
5,5
7,5
7,5
10
10
10
1,5
3
4
5,5
5,5
7,5
7,5
10
10
15
15
15
20
1,5
3
4
5,5
7,5
10
10
15
15
15
20
20
3
4
5,5
5,5
7,5
7,5
10
10
10
15
15
15
15
20
20
20
20
20
25
25
25
25
30
30
30
30

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

46SV1/1A
46SV1
46SV2/2A
46SV2
46SV3/2A
46SV3
46SV4/2A
46SV4
46SV5/2A
46SV5
46SV6/2A
46SV6
46SV7/2A
46SV7
46SV8/2A
46SV8
46SV9/2A
46SV9
66SV1/1A
66SV1
66SV2/2A
66SV2/1A
66SV2
66SV3/2A
66SV3/1A
66SV3
66SV4/2A
66SV4/1A
66SV4
66SV5/2A
66SV5/1A
66SV5
66SV6/2A
66SV6/1A
66SV6
66SV7/2A
66SV7/1A
66SV7
92SV1/1A
92SV1
92SV2/2A
92SV2
92SV3/2A
92SV3
92SV4/2A
92SV4
92SV5/2A
92SV5
92SV6/2A
92SV6
92SV7/2A
125SV1
125SV2
125SV3
125SV4
125SV5
125SV6
125SV7
125SV8/2A

(1) 1, 3, 5, 10, 15, 22SV Value referred to the F, T, R, N, V, C, K versions. P version excluded.

kW

HP

(1)

3
4
5,5
7,5
11
11
15
15
18,5
18,5
22
22
30
30
30
30
30
37
4
5,5
7,5
11
11
15
15
18,5
18,5
22
22
30
30
30
30
30
37
37
37
45
5,5
7,5
11
15
18,5
22
30
30
37
37
45
45
45
7,5
15
22
30
37
45
55
55

4
5,5
7,5
10
15
15
20
20
25
25
30
30
40
40
40
40
40
50
5,5
7,5
10
15
15
20
20
25
25
30
30
40
40
40
40
40
50
50
50
60
7,5
10
15
20
25
30
40
40
50
50
60
60
60
10
20
30
40
50
60
75
75

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
-

np = EFFICIENCY

For hydraulic performance values, consult the standard e-SVTM catalogue

HIGH
RE
TU
TEMPERA
TURE
TEMPERATU

Pp = POWER

1-125sv-HErP-2p50-en_a_th

33, 46SV Value referred to the G and N versions with PN 25 bar (2500 kPa). G and N versions with PN > 25 bar (2500 kPa) and P version are excluded.
66, 92SV Value referred to the G, N versions. P version excluded.

114

115

HIGH
TEMPERA
TU
RE
TEMPERATU
TURE

HIGH
TEMPERATURE
BOILER
...180C
(50/60 Hz)

ErP 2009/125/EC (50 Hz)


e-SV SERIES - HIGH TEMPERA
TURE BOILER (...180C)
TEMPERATURE
50/60 Hz
Background and context

HIGH
RE
TU
TEMPERA
TURE
TEMPERATU

In applications where industrial boilers are used, pumps


often have to deal with liquids at high temperatures. In
these installations, pumps need to be specifically cooled
down from excessive temperatures in the mechanical
seal area, in order to ensure high performance levels.
Thats why Lowara has developed the e-SVTM Boiler.
This pump has a standard mechanical seal which
extends its lifetime even when pumping liquids at very
high temperatures.

Benefits of e-SVTM Boiler

Boiler

Long-term mechanical seal performance


performance:
Thanks to the special design of its housing, the seal is
protected from the stress caused by high temperatures
by means of a natural lubrication process which is
triggered by the pumped liquid itself, and a cooling
system which uses the air in the room. A degasser is
also installed at the top of the pump in order to
automatically eliminate the air in the seal area. The
temperature decreased to 100C in the mechanical seal
area, together with the balanced mechanical seal and
the high quality of the elastomers of the e-SVTM Boiler
pump, assure excellent long-term performance, even in
the harshest operating conditions.

Special features / benefits

- Special design of the final stage of the


pump and of the mechanical seal chamber
for high temperature applications.
- Pump body and upper chamber in cast
AISI 316
316.
- Stainless steel PN25 degasser
degasser.
- Hard metal intermediate bush support
(tungsten carbide) to increase the duration and
capability of operating in extreme conditions, available
on all sizes.
- Balanced impeller design to reduce axial thrust
and extend the lifetime of standard motor bearings.
et to withstand pressures of up
- Double outer jack
jacket
to 25 bar and temperatures of up to 180C.
- IE2 or IE3 standard motors
motors, three-phase, 2-pole,
from 0,75 kW to 55 kW with fixed bearing to
endure extreme thrusts without limiting
inlet pressure
pressure.

Solidity
Solidity: e-SVTM Boiler pumps are designed to
operate in any application at temperatures up to 180C
and pressures up to 25 bar. Pump body and upper
chamber in cast AISI 316, balanced mechanical seal,
high quality elastomers, hard metal bush supports,
double outer jacket: these are the key features of the eSVTM Boiler. To select the correct pump, consult the
pressure-temperature diagram.
Easy and cost effective maintenance
maintenance: the
mechanical seal installed in e-SVTM Boiler pumps is a
standard balanced mechanical seal (EN12756) which
makes it cheap and easy to replace.

Identification code

Special configurations

B in
e-SVTM Boiler models are identified by the letter B
the standard identification code of the e-SVTM product
range and are available in AISI 316.

B015T
Example: 3SV13NB
B = Boiler.

A wide range of configurations is available for e-SVTM


Boiler pumps:
- Materials used: see the Materials section.
- Options for mechanical seals and gaskets:
see the mechanical seals and gaskets section.
- Options for motors and configuration:
see the motors section.

116

e-SV SERIES - HIGH TEMPERA


TURE BOILER (...180C)
TEMPERATURE
50/60 Hz
Technical specifications - Design
1: Balanced mechanical seal in order to withstand high pressures and temperatures.
2: Special upper chamber design with recirculation of the air in the room which lowers the temperature of the
mechanical seal.
3: Degasser to eliminate the air in the mechanical seal area.

Operating characteristics
For the hydraulic performances, please refer to the standard catalogue of e-SVTM.

Route of pumped liquid.

117

HIGH
TEMPERA
TU
RE
TEMPERATU
TURE

4: Double outer jacket design to withstand high pressures.

HIGH
RE
TU
TEMPERA
TURE
TEMPERATU

e-SV SERIES - HIGH TEMPERA


TURE BOILER (...180C) 50/60 Hz
TEMPERATURE
ELECTRIC PUMP CROS
S SECTION AND MAIN COMPONENTS
CROSS

1, 3, 5SV SERIES
10, 15, 22SV SERIES 4 kW
MATERIALI 1-22SV VERSIONI B
B VERSIONS
REF.

NAME

10, 15, 22SV SERIES 5,5 kW

REFERENCE STANDARDS

MATERIAL

N.

1
2
3
4
5
6
8
9
10
11
12
13
14
15
16
17
19
20

EUROPE

Pump body
Impeller
Diffuser
Outer sleeve
Shaft
Adapter
Coupling
Seal plate
Mechanical seal
Elastomers
Coupling protection
Shaft sleeve and bushing
Fill / drain plugs
Tie rods
Wear ring
Seal housing
Upper seal chamber
Air vent

Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Cast iron
EN 1561-GJL-250 (JL1040)
Aluminium
EN 1706-AC-AlSi11Cu2 (Fe) (AC46100)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Tungsten carbide
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Stainless steel
EN 10088-1-X17CrNi16-2 (1.4057)
Technopolymer PPS
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10088-1-X2CrNi19-11 (1.4306)

USA

AISI 316
AISI 316L
AISI 316L
AISI 316L
AISI 316
ASTM Class 35
AISI 316L

AISI 304
AISI 316
AISI 431
AISI 316
AISI 316
AISI 304L
1-22sv-b-en_a_tm

118

HIGH
TEMPERA
TU
RE
TEMPERATU
TURE

e-SV SERIES - HIGH TEMPERA


TURE BOILER (...180C) 50/60 Hz
TEMPERATURE
ELECTRIC PUMP CROS
S SECTION AND MAIN COMPONENTS
CROSS

33, 46, 66, 92SV SERIES


MATERIALI 33-125SV VERSIONI
B VERSIONS
REF.

NAME

125SV SERIES

B
REFERENCE STANDARDS

MATERIAL

N.

1
1A
2-3
2-3
4-4A
5
6
7
8
9-9A
10
11
12
13
14
15
16
17
20
21

EUROPE

Pump body
Lower support
Impeller, Diffuser 33SV-92SV
Impeller, Diffuser 125SV
Outer sleeve
Shaft
Adapter ( up to 45kW )
Adapter ( for higher powers )
Wear ring
Coupling ( up to 45kW )
Coupling ( for higher powers )
Upper head, Seal housing
Mechanical seal
Elastomers
Coupling protection
Shaft sleeve and bushing
Bushing for diffuser
Fill / drain / air plugs
Tie rods
Adapter ring
Air vent
Separating flange

Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10088-1-X2CrNiMo17-12-2 (1.4404)
EN 10088-1-X2CrNiMoN22-5-3 (1.4462)
Duplex stainless steel
Cast iron
EN 1561-GJL-200 (JL1030)
Cast iron
EN 1563-GJS-500-7 (JS1050)
Technopolymer PPS
Cast iron
EN 1561-GJL-200 (JL1030)
Cast iron
EN 1563-GJS-500-7 (JS1050)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Silicon carbide / Carbon / EPDM
EPDM
Stainless steel
EN 10088-1-X5CrNi18-10 (1.4301)
Tungsten carbide
Carbon
Stainless steel
EN 10088-1-X5CrNiMo17-12-2 (1.4401)
Stainless steel
EN 10088-1-X17CrNi16-2 (1.4057)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)
Stainless steel
EN 10088-1-X2CrNi19-11 (1.4306)
Stainless steel
EN 10213-4-GX5CrNiMo19-11-2 (1.4408)

USA

AISI 316
AISI 316
AISI 316L
AISI 316
AISI 316L
UNS S 31803
ASTM Class 25
ASTM A 536 80-55-06
ASTM Class 25
ASTM A 536 80-55-06
AISI 316

AISI 304

AISI 316
AISI 431
AISI 316
AISI 304L
AISI 316
33-125sv-b-en_a_tm

119

e-SV SERIES - HIGH TEMPERA


TURE BOILER (...180C) 50/60 Hz
TEMPERATURE
BALANCED MECHANICAL SEALS, ACCORDING TO EN 12756

HIGH
RE
TU
TEMPERA
TURE
TEMPERATU

1, 3, 5, 10, 15, 22SV

33, 46, 66, 92, 125SV

TENUTA MECCANICA SV MATERIALI VERSIONI ALTA TEMPERATURA

LIST OF MA
TERIALS
MATERIALS
POSITION 1 - 2

POSITION 3

Q 1 : Silicon Carbide
A : Carbon metal-impregned

E
V

POSITION 4 - 5

: EPDM
: FPM

: AISI 316

TENUTA MECCANICA SV COMBINAZIONI VERSIONI ALTA TEMPERATURA

TYPE OF SEAL
TYPE

ROTATING PART

STATIONARY PART

Q1 A E G G

Q1

Q1 A V G G
*Q 1 Q1 V G G

Q1
Q1

POSITION
3
ELASTOMERS

TEMPERATURE
4

SPRINGS

OTHER COMPONENTS

MECHANICAL SEAL FOR USE WITH WATER


A
E
G
OTHER TYPES OF AVAILABLE MECHANICAL SEAL
A
V
G
Q1
V
G

* Versions with anti-rotation lock pin of the fixed part.

sv-at_ten-mec-en_a_tm

( C )

-30 +150

G
G

-10 +150
-10 +150
sv-at_tipi-ten-mec-en_a_tc

PRES
SURE/TEMPERA
TURE APPLICA
TION LIMITS FOR COMPLETE PUMP
PRESSURE/TEMPERA
SURE/TEMPERATURE
APPLICATION
(APPLICABLE WITH ANY OF THE SEALS LISTED ABO
VE)
ABOVE)

120

e-SV SERIES - HIGH TEMPERA


TURE BOILER (...180C)
TEMPERATURE
DIMENSIONS A
T 50/60 Hz
AT
DIMENSIONI SERIE 1-22 SV-B 2 poli
PUMP
TYPE

DIMENSIONS
(mm)

AVAILABLE STAGES

FLANGES

LB

50Hz

60Hz

PN

1SV-B

*L1+105

0237

0226

25

3SV-B

*L1+105

0231

0221

25

5SV-B

*L1+105

0230

0221

25

10SV-B

*L1+147

0120

0113

25

15SV-B

*L1+153

0115

0111

25

22SV-B

*L1+153

0114

0110

25

DIMENSIONS

PUMP
TYPE

MOTOR TYPE

mm
X

1, 3, 5, 10, 15, 22SV SERIES

1SV 5SV

from 0,37 0,55 kW

1SV 5SV

from 0,75 1,1 kW

1SV 5SV

from 1,5 2,2 kW

1SV 5SV

from 3 4 kW

5SV

from 5,5 kW

10SV 22SV

from 0,75 1,1 kW

10SV 22SV

from 1,5 2,2 kW

10SV 22SV

from 3 4 kW

10SV 22SV

from 5,5 7,5 kW

10SV 22SV

from 11 18,5 kW

336
326

150

316
306

185

242
304

164

294
284
250

210

220
1-22sv-b-en_a_td

DIMENSIONI SERIE 33-125 SV-B 2 pol


PUMP

AVAILABLE STAGES

FLANGES

TYPE

DIMENSIONS
(mm)
LB

50Hz

60Hz

PN

33SV-B

*L1+225

1/1A9

1/1A6

25

46SV-B

*L1+225

1/1A9

1/1A6

25

66SV-B

*L1+235

1/1A7

1/1A5

25

92SV-B

*L1+235

125SV-B

*L1+235

1/1A7/2A 1/1A4/2A
18/2A

15/5A

25
25

*L1,*L2 = Standard product dimension, see e-SV catalogue.

DIMENSIONS

PUMP
TYPE

33SV 46SV

MOTOR TYPE

mm
X

from 2,2 4 kW

265

108

66SV

from 2,2 4 kW

265

119

33SV 46SV

from 5,5 7,5 kW

265

88

66SV 125SV

from 5,5 7,5 kW

265

99

33SV 46SV

from 11 45 kW

265

53

66SV 125SV

from 11 45 kW

265

64

125SV

from 55 kW

315

58

33-125sv-b-en_b_td

33, 46, 66, 92, 125SV SERIES

121

HIGH
TEMPERA
TU
RE
TEMPERATU
TURE

*L1,*L2 = Standard product dimension, see e-SV catalogue.

e-SV SERIES - HIGH TEMPERA


TURE BOILER (...180C)
TEMPERATURE
TABELLA DI PRESTAZI TABELLA DI PRESTAZIONI IDRAULICHE SERIE ALTA TEMPER
HYDRA
ULIC PERFORMANCE T
ABLE A
T 50 Hz, 2 POLES
HYDRAULIC
TABLE
AT
PUMP

RATED

TYPE

POWER

MEI

PUMP

RATED

TYPE

POWER

MEI

PUMP

RATED

TYPE

POWER

MEI

Q = DELIVERY
H = HEAD

1SV02
1SV03
1SV04
1SV05
1SV06
1SV07
1SV08
1SV09
1SV10
1SV11
1SV12
1SV13
1SV15
1SV17
1SV19
1SV22
1SV25
1SV27
1SV30
1SV32
1SV34
1SV37
3SV02
3SV03
3SV04
3SV05
3SV06
3SV07
3SV08
3SV09
3SV10
3SV11
3SV12
3SV13
3SV14
3SV16
3SV19
3SV21
3SV23
3SV25
3SV27
3SV29
3SV31
5SV02
5SV03
5SV04
5SV05
5SV06
5SV07
5SV08
5SV09
5SV10
5SV11
5SV12
5SV13
5SV14
5SV15
5SV16
5SV18
5SV21
5SV23
5SV25
5SV28
5SV30

kW

HP

(1)

0,37
0,37
0,37
0,37
0,37
0,37
0,55
0,55
0,55
0,55
0,75
0,75
0,75
1,1
1,1
1,1
1,5
1,5
1,5
2,2
2,2
2,2
0,37
0,37
0,37
0,55
0,55
0,75
0,75
1,1
1,1
1,1
1,1
1,5
1,5
1,5
2,2
2,2
2,2
2,2
3
3
3
0,37
0,55
0,55
0,75
1,1
1,1
1,1
1,5
1,5
1,5
2,2
2,2
2,2
2,2
2,2
3
3
4
4
4
5,5

0,5
0,5
0,5
0,5
0,5
0,5
0,75
0,75
0,75
0,75
1
1
1
1,5
1,5
1,5
2
2
2
3
3
3
0,5
0,5
0,5
0,75
0,75
1
1
1,5
1,5
1,5
1,5
2
2
2
3
3
3
3
4
4
4
0,5
0,75
0,75
1
1,5
1,5
1,5
2
2
2
3
3
3
3
3
4
4
5,5
5,5
5,5
7,5

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

10SV01
10SV02
10SV03
10SV04
10SV05
10SV06
10SV07
10SV08
10SV09
10SV10
10SV11
10SV13
10SV15
10SV17
10SV18
10SV20
15SV01
15SV02
15SV03
15SV04
15SV05
15SV06
15SV07
15SV08
15SV09
15SV10
15SV11
15SV13
15SV15
22SV01
22SV02
22SV03
22SV04
22SV05
22SV06
22SV07
22SV08
22SV09
22SV10
22SV12
22SV14
33SV1/1A
33SV1
33SV2/2A
33SV2/1A
33SV2
33SV3/2A
33SV3/1A
33SV3
33SV4/2A
33SV4/1A
33SV4
33SV5/2A
33SV5/1A
33SV5
33SV6/2A
33SV6/1A
33SV6
33SV7/2A
33SV7/1A
33SV7
33SV8/2A
33SV8/1A
33SV8
33SV9/2A
33SV9/1A
33SV9

kW

HP

(1)

0,75
0,75
1,1
1,5
2,2
2,2
3
3
4
4
4
5,5
5,5
7,5
7,5
7,5
1,1
2,2
3
4
4
5,5
5,5
7,5
7,5
11
11
11
15
1,1
2,2
3
4
5,5
7,5
7,5
11
11
11
15
15
2,2
3
4
4
5,5
5,5
7,5
7,5
7,5
11
11
11
11
15
15
15
15
15
18,5
18,5
18,5
18,5
22
22
22
22

1
1
1,5
2
3
3
4
4
5,5
5,5
5,5
7,5
7,5
10
10
10
1,5
3
4
5,5
5,5
7,5
7,5
10
10
15
15
15
20
1,5
3
4
5,5
7,5
10
10
15
15
15
20
20
3
4
5,5
5,5
7,5
7,5
10
10
10
15
15
15
15
20
20
20
20
20
25
25
25
25
30
30
30
30

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

46SV1/1A
46SV1
46SV2/2A
46SV2
46SV3/2A
46SV3
46SV4/2A
46SV4
46SV5/2A
46SV5
46SV6/2A
46SV6
46SV7/2A
46SV7
46SV8/2A
46SV8
46SV9/2A
46SV9
66SV1/1A
66SV1
66SV2/2A
66SV2/1A
66SV2
66SV3/2A
66SV3/1A
66SV3
66SV4/2A
66SV4/1A
66SV4
66SV5/2A
66SV5/1A
66SV5
66SV6/2A
66SV6/1A
66SV6
66SV7/2A
66SV7/1A
66SV7
92SV1/1A
92SV1
92SV2/2A
92SV2
92SV3/2A
92SV3
92SV4/2A
92SV4
92SV5/2A
92SV5
92SV6/2A
92SV6
92SV7/2A
125SV1
125SV2
125SV3
125SV4
125SV5
125SV6
125SV7
125SV8/2A

(1) 1, 3, 5, 10, 15, 22SV Value referred to the F, T, R, N, V, C, K versions. P version excluded.

kW

HP

(1)

3
4
5,5
7,5
11
11
15
15
18,5
18,5
22
22
30
30
30
30
30
37
4
5,5
7,5
11
11
15
15
18,5
18,5
22
22
30
30
30
30
30
37
37
37
45
5,5
7,5
11
15
18,5
22
30
30
37
37
45
45
45
7,5
15
22
30
37
45
55
55

4
5,5
7,5
10
15
15
20
20
25
25
30
30
40
40
40
40
40
50
5,5
7,5
10
15
15
20
20
25
25
30
30
40
40
40
40
40
50
50
50
60
7,5
10
15
20
25
30
40
40
50
50
60
60
60
10
20
30
40
50
60
75
75

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
0,60
-

np = EFFICIENCY

For hydraulic performance values, consult the standard e-SVTM catalogue

HIGH
RE
TU
TEMPERA
TURE
TEMPERATU

Pp = POWER

1-125sv-HErP-2p50-en_a_th

33, 46SV Value referred to the G and N versions with PN 25 bar (2500 kPa). G and N versions with PN > 25 bar (2500 kPa) and P version are excluded.
66, 92SV Value referred to the G, N versions. P version excluded.

122

123

e-SVH
HYDRO
VARTM
HYDROV

e-SVH
TM
(e-SV WITH
TM
HYDROVAR )
(50 Hz)

ErP 2009/125/EC (50 Hz)


e-SV SERIES - VERSION WITH HYDRO
VARTM
HYDROV
50 Hz
Background and context
In all areas of application, such as building services,
industry, agriculture and air-handling, the demand for
intelligent pumping systems is constantly growing.
There are many advantages: reduced cost for pump life
cycle, lower environmental impact, longer lifetime of
pipes and unions. Thats why Lowara has developed the
e-SVH: an intelligent pumping system which assures
high level performance with energy consumption
tailored to demand.

e-SVH
HYDRO
VARTM
HYDROV

Benefits of e-SVH with HYDRO


VARTM
HYDROV

Saving
Saving: e-SVH transform e-SVTM pumps into variable
speed intelligent pumping systems. Thanks to the
HYDROVARTM system, the speed of each pump varies so
as to maintain a constant flow or pressure. The pump
only receives the energy required, thus allowing
considerable savings, especially for those systems in
which demands varies during the day.

Easy installation and space-saving


space-saving: e-SVH save
time and space during installation. Installed directly on
the motor, which cools it down, and does not require a
further control panel. Thanks to the HYDROVARTM
technology, there is no need for large diaphragm tanks
to complete installation.

Special features / benefits

- There is no need for additional pressure


sensors
sensors: e-SVH are fitted with a pressure transmitter
or differential pressure transmitters, depending on the
application.
- There is no need for special pumps or
motors
motors.
Standard motors
motors: e-SVH are fitted with three-phase
There is no need for bypass or safety
standard TEFC motors with insulation class 155 (F) and
systems
systems: With HYDROVARTM the pump immediately
power outputs of up to 22 kW.
The wall-mounted HYDROVARTM version is available for switches off when demand drops to zero or when it
exceeds maximum pump capacity. This makes it
higher power outputs (up to 45 kW).
unnecessary to install additional safety devices.
- Anti-condensation device
device: all units are fitted
Identification code
with anti-condensation devices which switch on when
H in the
e-SVH models are identified by the letter H
the pump is in standby in order to prevent
standard identification code of the e-SVTM product
condensation forming in the unit.
range.
- i-ALERTTM device to reduce the costs for each life
cycle, thus increasing the mean time between failures
H13F015T
Example: 3SVH
(MTBF).
H = with integrated HYDROVARTM.

Special configurations
e-SVH have the same range of configurations as the
standard e-SVTM series.
- Materials used: see the Materials section.
- Options for mechanical seals and gaskets:
see the mechanical seals and gaskets section.
- Options for motors and configuration:
see the motors section.

124

e-SV SERIES - VERSION WITH HYDRO


VARTM
HYDROV
OPERA
TING PRINCIPLE
OPERATING
The basic function of the HYDROVARTM device is to
control the pump to meet the system demands.
HYDRO
VARTM performs these functions by
HYDROV
by:
1) Measuring the system pressure or flow via a
transmitter mounted on the pumps delivery side.
2) Calculating the motor speed to maintain the correct
flow or pressure.
3) Sending out a signal to the pump to start the motor,
increase speed, decrease speed or stop.
4) In the case of multiple pump installations, HYDROVARTM
will automatically provide for the cyclic changeover of the
pumps starting sequence.
In addition to these basic functions, HYDROVARTM can do
things only by the most advanced computerised control
systems, such as:
Stop the pump(s) at zero demand.
Stop the pump(s) in case of water failure on the
suction side (protection against dry running).
Stop the pump if the required delivery exceeds the
pumps capacity (protection against cavitation caused
by excessive demand), or automatically switch on the
next pump in a multiple series.
Protect the pump and motor from overvoltage,
undervoltage, overload and earth fault.
Vary the pump speed acceleration and deceleration time.
Compensate for increased flow resistance at high flow
rates.
Conduct automatic test starts at set intervals.
Monitor the converter and motor operating hours.
Display all functions on an LCD in different languages
(Italian, English, French, German, Spanish, Portuguese,
Dutch).
Send a signal to a remote control system which is
proportional to the pressure and frequency.
Communicate with another HYDROVARTM or control
system via an RS 485 interface.

e-SVH
HYDRO
VARTM
HYDROV

Control for constant pressure

Control to match a system curve

Control for constant flow

Control according to an external signal

TYPICAL EXAMPLE OF ENERG


Y SA
VINGS
ENERGY
SAVINGS
System: 22SV07F75T vertical multistage electric pump with 7,5 kW motor equipped with HYDROVARTM, 70 m head.
19 hour/day operation.
TABELLA RISPARMIO
Application:
maintaining ENERGETICO
a constant pressure as the flow rate varies according to the system curve.
ABSORBED POWER

FLOW

CONSTANT SPEED

VARIABLE SPEED

POWER

OPERATING

TOTAL

SAVED

TIME

ENERGY

PUMP

PUMP

3
m /h

kW

kW

kW

(hours)

SAVINGS
kWh

24
21
18
14
10

7,4
6,9
6,5
5,6
5,1

7,4
6,1
5,0
3,8
2,8

0,0
0,8
1,5
1,8
2,3

876
876
1752
1752
1752

701
2.628
3.154
4.030

YEARLY ENERGY SAVINGS (kWh)

10.512
sv-hydr-en_a_te

125

1,
3, 5, 10, 15, 22SVH SERIES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE 1SVH 3SVH 5SVH 2p 50 Hz
HYDRA
ULIC PERFORMANCE T
ABLE A
T 50 Hz, 2 POLES
HYDRAULIC
TABLE
AT
PUMP

RATED

TYPE

POWER

kW

12

20

25

30

35

40

45

50

60

73

100

120

141

m3/h 0

0,7

1,2

1,5

1,8

2,1

2,4

2,7

3,0

3,6

4,4

6,0

7,2

8,5

H = TOTAL HEAD IN METRES OF COLUMN OF WATER

HP

1SVH15

0,75

90,9

90,5

85,6

79,3

70,1

58,1

43,1

1SVH22

1,1

1,5

134,6

134,1

127,4

118,1

104,4

86,1

63,5

1SVH30

1,5

181,7

181,3

172,6

160,1

141,2

115,7

83,9

1SVH37

2,2

225,9

224,9

216,1

201,9

179,3

148,1

108,7

3SVH08

0,75

60,0

59,1

58,2

57,0

55,4

53,4

51,0

48,1

40,7

3SVH12

1,1

1,5

89,6

87,8

86,4

84,5

82,1

79,1

75,5

71,1

59,9

40,1

3SVH16

1,5

119,9

117,8

116,1

113,6

110,5

106,5

101,6

95,8

80,9

54,2

3SVH21

2,2

159,3

156,9

154,6

151,4

147,3

142,1

135,7

128,0

108,5

73,6

3SVH25

2,2

188,5

186,1

183,3

179,3

174,1

167,6

159,7

150,3

126,6

84,8

3SVH29

219,3

216,0

212,8

208,3

202,6

195,3

186,4

175,7

148,6

100,2

3SVH33

248,5

245,3

241,5

236,2

229,3

220,7

210,2

197,7

166,3

111,2

38,0

36,4

36,0

35,5

34,5

32,9

28,2

23,5

17,1

1,5

60,1

57,6

57,0

56,2

54,6

51,8

44,1

36,2

25,8

82,8

79,3

78,4

77,5

75,2

71,4

60,7

49,9

35,6

102,0

100,9

99,6

96,6

91,7

77,8

64,0

46,3

5SVH05
5SVH08
5SVH11

e-SVH
HYDRO
VARTM
HYDROV

Q = DELIVERY
l/min 0

0,75
1,1
1,5

27,5

5SVH14

2,2

105,7

5SVH16

2,2

120,5

115,9

114,6

113,1

109,6

103,9

87,8

72,1

51,8

5SVH21

157,9

152,0

150,3

148,3

143,6

136,1

114,9

94,2

67,6

5SVH28

5,5

211,5

204,2

201,9

199,4

193,3

183,4

155,5

128,0

92,7

5SVH33

5,5

7,5

249,2

241,0

238,4

235,5

228,4

216,9

184,2

151,9

110,3

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A).

1-5svh-2p50-en_c_th

TABELLA DI PRESTAZIONI IDRAULICHE SERIE 10SVH 15SVH 22SVH 2p 50 Hz


PUMP

RATED

TYPE

POWER

Q = DELIVERY
l/min 0

83,34

100

133

170

183,34

233

270

330

350

400

430

460

483,33

m3/h 0

5,0

6,0

8,0

10,2

11,0

14,0

16,2

19,8

21,0

24,0

25,8

27,6

29,0

H = TOTAL HEAD IN METRES OF COLUMN OF WATER

kW

HP

10SVH04

1,5

47,7

44,2

43,0

39,9

34,8

32,6

21,7

10SVH06

2,2

71,8

66,8

65,0

60,4

53,1

49,8

33,9

10SVH08

95,3

88,9

86,5

80,1

70,2

65,7

44,5

10SVH11

5,5

129,6

121,3

118,1

109,6

96,3

90,3

62,1

10SVH15

5,5

7,5

179,5

167,9

163,4

151,6

132,8

124,3

83,9

10SVH20

7,5

10

240,6

226,0

220,3

205,0

180,2

168,9

114,3

10SVH21

11

15

253,6

241,0

235,5

220,2

195,0

183,5

127,5

15SVH02

2,2

28,7

26,7

25,9

25,5

23,9

22,4

18,9

17,4

13,1

15SVH03

43,3

40,4

39,1

38,6

36,2

33,8

28,7

26,5

20,1

15SVH05

5,5

72,7

67,8

65,8

65,0

61,0

57,1

48,7

45,2

34,9

15SVH07

5,5

7,5

101,9

94,5

91,9

90,8

85,7

80,6

69,4

64,7

50,5

15SVH09

7,5

10

131,9

124,4

121,0

119,6

112,8

106,1

91,5

85,5

67,4

15SVH13

11

15

191,3

179,2

174,5

172,5

163,1

153,7

133,1

124,5

98,6

15SVH17

15

20

251,6

237,3

231,4

228,9

216,9

205,0

178,4

167,3

133,6

22SVH01

1,1

1,5

14,7

13,5

12,7

12,0

10,4

9,7

7,7

6,3

4,7

3,4

22SVH03

45,4

42,2

40,4

38,5

34,5

32,8

27,8

24,2

20,2

16,6

22SVH04

5,5

60,9

56,8

54,4

51,9

46,6

44,4

37,9

33,1

27,7

23,0

7,5

76,0

70,9

67,9

64,9

58,3

55,6

47,4

41,4

34,7

28,8

103,1

99,4

95,7

87,2

83,7

73,1

65,3

56,5

48,8

22SVH05

5,5

22SVH07

7,5

10

108,5

22SVH10

11

15

155,4

148,2

143,1

137,8

125,9

120,9

105,8

94,8

82,3

71,3

22SVH14

15

20

216,6

207,7

200,9

193,7

177,4

170,4

149,4

133,9

116,1

100,6

22SVH17

18,5

25

263,5

252,8

244,7

236,0

216,2

207,8

182,3

163,6

142,0

123,2

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A).

126

10-22svh-2p50-en_c_th

33, 46, 66, 92SVH SERIES


TABELLA DI PRESTAZIONI IDRAULICHE SERIE 33SVH-46SVH 2 poli 50 Hz
HYDRA
ULIC PERFORMANCE T
ABLE A
T 50 Hz, 2 POLES
HYDRAULIC
TABLE
AT
RATED

TYPE

POWER

Q = DELIVERY
l/min 0
3

m /h 0

250

300

367

417

500

583

667

750

900

1000

15

18

22

25

30

35

40

45

54

60

H = TOTAL HEAD METRES COLUMN OF WATER

kW

HP

33SVH1

23,8

33SVH2

5,5

7,5

33SVH3

7,5

10

33SVH4

11

15

33SVH5

15

20

21,7

21,2

20

20

17,8

47,8

45

44,1

43

41

39

35

29,9

71,5

67,4

66,0

64

62

58

52,0

44,6

95,9

91,1

90

87

85

80

73

63,1

120,4 114,9

113

110

107

101

92

80,5

139

15,5

12,7

33SVH6

15

20

145,6

33SVH7

18,5

25

170,3 162,8

137

133

129

121

110

96,1

160

156

152

142

130

113,3

46SVH1

5,5

27,2

24

23,5

22,5

21,4

19,9

18,2

14,3

10,8

46SVH2

7,5

10

52,6

48,5

47,7

46,1

44,2

41,7

38,7

31,4

25,1

46SVH3

11

15

80,8

74,3

73

71

68

65

60

50

40,7

46SVH4

15

20

107,3

99,8

98

96

92

87

82

68

55,9

46SVH6

22

30

161

149,9

148

144

139

132

124

104

86

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A).

33-46svh-2p50-en_b_th

TABELLA DI PRESTAZIONI IDRAULICHE SERIE 66SVH-92SVH 2 poli 50 Hz


PUMP

RATED

TYPE

POWER

Q = DELIVERY
l/min 0

500

600

700

750

900

1000

1200

1300

1417

1600

1800

2000

m3/h 0

30

36

42

45

54

60

72

78

85

96

108

120

H = TOTAL HEAD METRES COLUMN OF WATER

kW

HP

66SVH1

5,5

7,5

29,2

25,8

24,8

23,8

23,3

21,8

20,7

17,9

16,1

13,5

66SVH2

11

15

60,4

55,7

54,4

52,8

52

49,3

47,1

42

38,9

34,7

66SVH3

18,5

25

91,4

84,7

83

81

79

75

72

64

60

53,5

66SVH4

22

30

121,6 112,5

110

107

105

100

96

86

79

70,8

92SVH1

7,5

10

33,5

28,7

27,2

26,2

24,3

23,3

22,2

20,2

17,6

14,3

92SVH2

15

20

67,8

58,2

55

53

49,5

47,6

45,2

41,4

36,3

29,6

92SVH3

22

30

102,2

88,2

84

81

76

73

69

63

56

46,3

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A).

127

66-92svh-2p50-en_b_th

e-SVH
HYDRO
VARTM
HYDROV

PUMP

PUMP

NOMINAL

TYPE

POWER

1SVH15
1SVH22
1SVH30
1SVH37
3SVH08
3SVH12
3SVH16
3SVH21
3SVH25
3SVH29
3SVH33
5SVH05
5SVH08
5SVH11
5SVH14
5SVH16
5SVH21
5SVH28
5SVH33
10SVH04
10SVH06
10SVH08
10SVH11
10SVH15
10SVH20
10SVH21
15SVH02
15SVH03
15SVH05
15SVH07
15SVH09
15SVH13
15SVH17
22SVH01
22SVH03
22SVH04
22SVH05
22SVH07
22SVH10
22SVH14
22SVH17
33SVH1
33SVH2
33SVH3
33SVH4
33SVH5
33SVH6
33SVH7
46SVH1
46SVH2
46SVH3
46SVH4
46SVH6
66SVH1
66SVH2
66SVH3
66SVH4
92SVH1
92SVH2
92SVH3

MEI

SVH..M

SVH..T

INPUT
CURRENT (2)
1X230 V

INPUT
CURRENT (2)
3X400 V

kW

HP

(1)

0,75
1,1
1,5
2,2
0,75
1,1
1,5
2,2
2,2
3
3
0,75
1,1
1,5
2,2
2,2
3
4
5,5
1,5
2,2
3
4
5,5
7,5
11
2,2
3
4
5,5
7,5
11
15
1,1
3
4
5,5
7,5
11
15
18,5
3
5,5
7,5
11
15
15
18,5
4
7,5
11
15
22
5,5
11
18,5
22
7,5
15
22

1
1,5
2
3
1
1,5
2
3
3
4
4
1
1,5
2
3
3
4
5,5
7,5
2
3
4
5,5
7,5
10
15
3
4
5,5
7,5
10
15
20
1,5
4
5,5
7,5
10
15
20
25
4
7,5
10
15
20
20
25
5,5
10
15
20
30
7,5
15
25
30
10
20
30

0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,6
0,6
0,6

5,4
7,5
10,0
14,6
5,4
7,5
10,0
14,6
14,6
5,4
7,5
10,0
14,6
14,6
10,0
14,6
14,6
7,5
-

2,5
3,3
4,9
2,5
3,3
4,9
4,9
6,4
6,4
2,5
3,3
4,9
4,9
6,4
8,1
10,9
3,3
4,9
6,4
8,1
10,9
14,7
21,4
4,9
6,4
8,1
10,9
14,7
21,4
27,4
2,5
6,4
8,1
10,9
14,7
21,4
27,4
34,9
6,4
10,9
14,7
21,4
27,4
27,4
34,9
8,1
14,7
21,4
27,4
40,6
10,9
21,4
34,9
40,6
14,7
27,4
40,6

-1

(1) Values referred to operation at 2900 min (50 Hz).

Q = DELIVERY
H = HEAD
Pp = POWER
np = EFFICIENCY

For hydraulic performance values, consult the standard e-SVTM catalogue

e-SVH
HYDRO
VARTM
HYDROV

1, 3, 5, 10, 15, 22, 33, 46, 66, 92SVH SERIES


ELECTRICAL DA
TA T
ABLE A
T 50 Hz
DAT
TABLE
AT

1-92svh-2p50-en_c_te

1, 3, 5, 10, 15, 22SV Value referred to versions F, T, R, N, V, C, K. P version excluded.


33, 46SV Value referred to the G and N versions with PN 25 bar (2500 kPa). G and N versions with PN > 25 bar (2500 kPa) and P version excluded.
66, 92SV Value referred to the G, N versions. P version excluded.
-1
(2) Nominal values referred to operation at 2900 min (50 Hz).

128

e-SVH
HYDRO
VARTM
HYDROV

1SVH SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz
AT

DIMENSIONI E PESI SERIE 1SVH 2 poli 50 Hz


PUMP

MOTOR

DIMENSIONS (mm)

TYPE

L2

WEIGHT kg
M

D1

ELECTRIC

kW

SIZE

L1

3~

L7

3~

3~

D2

PUMP

PUMP

1SVH15../D

0,75

80

528

263

170

225

129

155

120

13,9

23,6

1SVH22../D

1,1

80

668

263

170

225

129

155

120

16,7

28,6

1SVH30../D

1,5

90

838

263

170

225

129

155

140

20,7

34

1SVH37..

2,2

90

978

298

170

225

134

174

140

23,5

40

1svh-2p50-en_b_td

129

e-SVH
HYDRO
VARTM
HYDROV

3SVH SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz
AT

DIMENSIONI E PESI SERIE 3SVH 2 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

TYPE

L2

WEIGHT kg
M

D1

ELECTRIC

kW

SIZE

L1

3~

L7

3~

3~

D2

PUMP

PUMP

3SVH08../D

0,75

80

388

263

170

225

129

155

120

11,3

20,9

3SVH12../D

1,1

80

468

263

170

225

129

155

120

13,3

24,7

3SVH16../D

1,5

90

558

263

170

225

129

155

140

15,2

28,2

3SVH21..

2,2

90

658

298

170

225

134

174

140

17,2

35,2

3SVH25..

2,2

90

738

298

170

225

134

174

140

18,9

36,8

3SVH29..

100

828

298

170

225

134

174

160

21,5

43,4

3SVH33..

100

908

298

170

225

134

174

160

23,1

45

3svh-2p50-en_b_td

130

e-SVH
HYDRO
VARTM
HYDROV

5SVH SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz
AT

DIMENSIONI E PESI SERIE 5SVH 2 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

TYPE

L2

WEIGHT kg
M

D1

ELECTRIC

kW

SIZE

L1

3~

L7

3~

3~

D2

PUMP

PUMP

5SVH05../D

0,75

80

353

263

170

225

129

155

120

10,5

20,1

5SVH08../D

1,1

80

428

263

170

225

129

155

120

12,1

23,5

5SVH11../D

1,5

90

513

263

170

225

129

155

140

13,6

27

5SVH14..

2,2

90

588

298

170

225

134

174

140

15

33,2

5SVH16..

2,2

90

638

298

170

225

134

174

140

16

34,2

5SVH21..

100

773

298

170

225

134

174

160

19,4

40,4

5SVH28..

112

948

319

170

225

154

197

160

23

49,4

5SVH33..

5,5

132

1093

375

170

293

168

214

300

29,5

67,1
5svh-2p50-en_b_td

131

e-SVH
HYDRO
VARTM
HYDROV

10SVH SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz
AT

DIMENSIONI E PESI SERIE 10SVH 2 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

TYPE

L2

WEIGHT kg
M

D1

ELECTRIC

kW

SIZE

L1

3~

L7

3~

3~

D2

PUMP

10SVH04../D

1,5

90

431

263

170

225

129

155

140

17,6

31

10SVH06..

2,2

90

495

298

170

225

134

174

140

19,7

37,9

10SVH08..

100

569

298

170

225

134

174

160

22,4

43,4

10SVH11..

112

665

319

170

225

154

197

160

25,2

52

10SVH15..

5,5

132

860

375

170

293

168

214

300

35

73

10SVH20..

7,5

132

1020

367

170

293

191

256

300

39,6

96

10SVH21..

11

160

1082

428

170

293

191

256

350

42,2

113

PUMP

10svh-2p50-en_b_td

132

e-SVH
HYDRO
VARTM
HYDROV

15SVH SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz
AT

DIMENSIONI E PESI SERIE 15SVH 2 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

TYPE

L2

WEIGHT kg
M

D1

ELECTRIC

kW

SIZE

L1

3~

L7

3~

3~

D2

PUMP

PUMP

15SVH02..

2,2

90

409

298

170

225

134

174

140

16,8

34,7

15SVH03..

100

467

298

170

225

134

174

160

19

40

15SVH05..

112

563

319

170

225

154

197

160

21,5

47,9

15SVH07..

5,5

132

726

375

170

293

168

214

300

30,2

68

15SVH09..

7,5

132

822

367

170

293

191

256

300

32,8

90

15SVH13..

11

160

1044

428

170

293

191

256

350

41

112

15SVH17..

15

160

1236

494

209

440

240

313

350

46,7

149

15svh-2p50-en_b_td

133

e-SVH
HYDRO
VARTM
HYDROV

22SVH SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz
AT

DIMENSIONI E PESI SERIE 22SVH 2 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

TYPE

L2

WEIGHT kg
M

D1

ELECTRIC

kW

SIZE

L1

3~

L7

3~

3~

D2

PUMP

PUMP

1,1

80

399

263

170

225

129

155

120

15,5

26,9

22SVH03..

100

467

298

170

225

134

174

160

19,4

40,4

22SVH04..

112

515

319

170

225

154

197

160

20,7

47,1

22SVH05..

5,5

132

630

375

170

293

168

214

300

26,7

65

22SVH07..

7,5

132

726

367

170

293

191

256

300

29,3

86

22SVH10..

11

160

900

428

170

293

191

256

350

35,8

107

22SVH14..

15

160

1092

494

209

440

240

313

350

41,1

144

22SVH17..

18,5

160

1236

494

209

440

240

313

350

45,1

156

22SVH01../D

22svh-2p50-en_b_td

134

e-SVH
HYDRO
VARTM
HYDROV

33SVH SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz
AT

DIMENSIONI E PESI SERIE 33SVH 2 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

ELECTRIC
kW

SIZE

L1

L2

L7

D1

D2

PN

PUMP

33SVH1..

100

489

288

170

225

178

164

137

16

52

PUMP

71

33SVH2..

5,5

132

584

375

170

293

214

300

168

16

61

98,5

33SVH3..

7,5

132

659

367

170

293

256

300

191

16

65

121

33SVH4..

11

160

769

428

170

293

256

350

191

16

73

143

33SVH5..

15

160

844

494

209

440

313

350

240

16

77

179

33SVH6..

15

160

919

494

209

440

313

350

240

25

81

183

33SVH7..

18,5

160

994

494

209

440

313

350

240

25

84

195

33svh-2p50-en_b_td

135

e-SVH
HYDRO
VARTM
HYDROV

46SVH SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz
AT

DIMENSIONI E PESI SERIE 46SVH 2 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

ELECTRIC
kW

SIZE

L1

L2

L7

D1

D2

PN

PUMP

PUMP

46SVH1..

112

529

319

170

225

197

164

154

16

58

84,5

46SVH2..

7,5

132

624

367

170

293

256

300

191

16

66

122

46SVH3..

11

160

734

428

170

293

256

350

191

16

74

144

46SVH4..

15

160

809

494

209

440

313

350

240

16

78

180

46SVH6..

22

180

959

494

209

440

313

350

240

25

87

208

46svh-2p50-en_b_td

136

e-SVH
HYDRO
VARTM
HYDROV

66SVH SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz
AT

DIMENSIONI E PESI SERIE 66SVH 2 poli 50 Hz


PUMP

MOTOR

DIMENSIONS (mm)

WEIGHT kg

TYPE

ELECTRIC
kW

SIZE

L1

L2

L7

D1

D2

PN

PUMP

PUMP

66SVH1..

5,5

132

574

375

170

293

214

300

168

16

72

110

66SVH2..

11

160

699

428

170

293

256

350

191

16

81

151

66SVH3..

18,5

160

789

494

209

440

313

350

240

16

86

197

66SVH4..

22

180

879

494

209

440

313

350

240

16

93

214

66svh-2p50-en_b_td

137

e-SVH
HYDRO
VARTM
HYDROV

92SVH SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz
AT

DIMENSIONI E PESI SERIE 92SVH 2 poli 50 Hz


PUMP

MOTOR

DIMENSIONS (mm)

WEIGHT kg

TYPE

ELECTRIC
kW

SIZE

L1

L2

L7

D1

D2

PN

PUMP

92SVH1..

7,5

132

574

367

170

293

256

300

191

16

71

PUMP

127

92SVH2..

15

160

699

494

209

440

313

350

240

16

80

182

92SVH3..

22

180

789

494

209

440

313

350

240

16

87

208

92svh-2p50-en_b_td

138

1SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
1SV15
0
0

ISO 9906:2012 - Grade 3B

2
2

1SV22

10 Q [Imp gpm]

12 Q [US gpm]

10

2
2

10 Q [Imp gpm]

12 Q [US gpm]

10

500

H [m]

H [m]

H [ft]

160

H [ft]

100

ISO 9906:2012 - Grade 3B

300

140

80
250

100

200

60

400

120

300
80
150
40

200

60
100
40

20

100
50

10
2

15
4
10
2

0
0,4

0,8

10

1,6

20

2,4 Q [m /h] 2,8

2,0

30

40

Q [l/min]
50

1SV30

ISO 9906:2012 - Grade 3B

10 Q [Imp gpm]

0
0

1,2

06623_B_CH

0,0

0,4

0,8

1,2

10

1,6

20

0
0

2,4 Q [m /h] 2,8

2,0

30

1SV37

12 Q [US gpm]

10

0
0,0

40

Q [l/min]
50

ISO 9906:2012 - Grade 3B

2
2

10 Q [Imp gpm]

12 Q [US gpm]

10

250

800

H [ft]

600

H [ft]

H [m]

H [m]

200

06624_B_CH

200

500

150

600

400

150

100

400

300
100

200
50

200
50

100

NPSH [m]

15
4
10

15
4

NPSH [ft]

0
6

NPSH [ft]

10
2

0
0,0
0

0,4

0,8
10

1,2
20

1,6
30

2,4 Q [m /h] 2,8

2,0
40

Q [l/min]
50

06625_B_CH

0
0,0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

139

0,4

0,8
10

1,2
20

1,6
30

2,4 Q [m /h] 2,8

2,0
40

Q [l/min]
50

06626_B_CH

NPSH [m]

0
6

e-SVH
HYDRO
VARTM
HYDROV

NPSH [m]

15
4

0
6

NPSH [ft]

NPSH [ft]

NPSH [m]

0
6

20

3SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
ISO 9906:2012 - Grade 3B

10

15

10

3SV12

Q [Imp gpm]

20 Q [US gpm]

15

20

10

30

20

Q [Imp gpm]
40 Q [US gpm]

30

H [m]

H [m]

180
50

10

100

H [ft]

60

ISO 9906:2012 - Grade 3B

H [ft]

3SV08

160

300

80
250

140
40
120

200

60

100

30

150
80

40

20
60

100

40

20

10

50
20

NPSH [m]

15
4

0
6

10
2

15
4

NPSH [ft]

NPSH [ft]

10
2

0
2

10

3SV16

Q [m3/h]

4
12

14

16
Q [l/min]

0
0
0

10

15

10

Q [Imp gpm]

H [m]

450

60

3
80

Q [m3/h]

100

120

140

160
Q [l/min]

ISO 9906:2012 - Grade 3B


5

10

15

10

Q [Imp gpm]
20 Q [US gpm]

15

180

400

120

40

20 Q [US gpm]

15

140

20

H [ft]

3SV21

ISO 9906:2012 - Grade 3B

H [m]

H [ft]

06629_B_CH

06630_B_CH

NPSH [m]

e-SVH
HYDRO
VARTM
HYDROV

0
6

160
500
140

350
100

80

300

120

250

100

200

80

150

60

100

40

50

20

0
6

400

300
60

200

40

100

10
2

15
4

NPSH [ft]

15
4

NPSH [m]

10
2

0
0
0

2
20

3
40

4
60

Q [m3/h]

80
Q [l/min]

0
06631_B_CH

0
0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

140

2
20

3
40

4
60

Q [m3/h]

80
Q [l/min]

06632_B_CH

NPSH [m]

0
6

NPSH [ft]

20

3SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
ISO 9906:2012 - Grade 3B

10

15

10

3SV29

Q [Imp gpm]

20 Q [US gpm]

15

10

15

10

Q [Imp gpm]
20 Q [US gpm]

15

800

H [m]

H [m]

250

H [ft]

200

ISO 9906:2012 - Grade 3B

600

H [ft]

3SV25

700
200
500

150

600

400

500

150

100

400
300
100
300
200

50

200
50
100
100

10
2

15
4
10
2

2
20

40

60

3SV33

Q [m3/h]

80
Q [l/min]

ISO 9906:2012 - Grade 3B

10

15

10

Q [Imp gpm]
20 Q [US gpm]

15

H [m]

H [ft]

300
900
250

800

700
200
600

500

150

400
100
300

200
50
100

15
4

NPSH [ft]

NPSH [m]

0
6

10
2
5

0
0
0

2
20

3
40

4
60

Q [m3/h]

80
Q [l/min]

06636_B_CH

0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

141

2
20

3
40

4
60

Q [m3/h]

80
Q [l/min]

06634_B_CH

0
0

06633_B_CH

e-SVH
HYDRO
VARTM
HYDROV

NPSH [m]

15
4

0
6

NPSH [ft]

NPSH [ft]

NPSH [m]

0
6

5SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
5SV05

5SV08

ISO 9906:2012 - Grade 3B

10

20

10

30

20

Q [Imp gpm]

40 Q [US gpm]

30

10

20

10

30

20

Q [Imp gpm]
40 Q [US gpm]

30

25

H [m]

H [ft]

100

30

H [ft]

70

35

H [m]

ISO 9906:2012 - Grade 3B

200

60

50

80

150
40

20
60

100

30

15
40

20

10

50
20
10

0
3

NPSH [m]

NPSH [ft]

NPSH [m]

2
6

2
20

4
40

60

6
80

5SV11

Q [m /h]

100

120

140

10

160
Q [l/min]

0
0

ISO 9906:2012 - Grade 3B

10

20

10

30

20

Q [Imp gpm]

60

6
80

100

Q [m /h]

8
120

140

10

160 Q [l/min]

ISO 9906:2012 - Grade 3B

10

20

10

30

20

Q [Imp gpm]
40 Q [US gpm]

30

120

H [m]

H [ft]

100

H [m]

4
40

5SV14

40 Q [US gpm]

30

2
20

H [ft]

06638_B_CH

1
3

06637_B_CH

300

100
80
250

300
80

200

60

200

60
150
40
40
100

100
20

0
3

NPSH [ft]

20

NPSH [m]

50

NPSH [ft]

0
3

NPSH [m]

2
6

4
1

0
0

2
20

4
40

60

6
80

100

Q [m3/h]

8
120

140

160

10
Q [l/min]

0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

142

2
20

4
40

60

6
80

100

Q [m3/h]

8
120

140

10

160Q [l/min]

06640_B_CH

1
06639_B_CH

e-SVH
HYDRO
VARTM
HYDROV

0
3

NPSH [ft]

5SVH SERIES
OPERA
TING CHARACTERISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTICS
AT
5SV16
10

20

10

30

20

Q [Imp gpm]

40 Q [US gpm]

30

10

20

10

30

20

Q [Imp gpm]
40 Q [US gpm]

30

180

H [m]

H [ft]

140

400

120

ISO 9906:2012 - Grade 3B

H [ft]

H [m]

5SV21

ISO 9906:2012 - Grade 3B

160
500
140

100
400

120

300
80

100
300
80

200

60

200

60
40
40

100

100

20
20

2
6

2
20

4
40

60

6
80

5SV28

Q [m /h]

100

120

140

10

160
Q [l/min]

0
0

ISO 9906:2012 - Grade 3B

10

20

10

30

20

Q [Imp gpm]

250

4
40

6
80

Q [m /h]

100

120

140

10

160 Q [l/min]

ISO 9906:2012 - Grade 3B

10

20

10

30

20

Q [Imp gpm]
40 Q [US gpm]

30

300

H [m]

H [m]

800

60

5SV33

40 Q [US gpm]

30

2
20

H [ft]

H [ft]

06642_B_CH

1
3

06641_B_CH

250

800

200
600
200

600

150
150

400

400

100
100
200

200

50
50

NPSH [ft]

NPSH [ft]

0
3

NPSH [m]

NPSH [m]

0
3

2
6

0
0

2
20

4
40

60

6
80

100

Q [m3/h]

8
120

140

10

160 Q [l/min]

0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

143

2
20

4
40

60

6
80

100

Q [m3/h]

8
120

140

10

160 Q [l/min]

06644_B_CH

1
06643_B_CH

e-SVH
HYDRO
VARTM
HYDROV

NPSH [ft]

NPSH [ft]

0
3

NPSH [m]

NPSH [m]

0
3

10SVH SERIES
OPERA
TING CHARACTERISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTICS
AT
0

ISO 9906:2012 - Grade 3B

10

20

30

20

10SV06

50 Q [Imp gpm]

40
40

60

Q [US gpm]

20

30

20

50 Q [Imp gpm]

40
40

60

Q [US gpm]
250

H [m]

H [m]

10

80

H [ft]

60

ISO 9906:2012 - Grade 3B

H [ft]

10SV04

50
150

60

100

40

200

40
150
30

100
20
50

20
50

10

NPSH [ft]

NPSH [m]

0
3

NPSH [ft]

NPSH [m]

6
2
4

0
2

50

100

10
150

14 Q [m3/h] 16

200

10SV08
0

12

250 Q [l/min]

0
0
0

ISO 9906:2012 - Grade 3B

10

20

30

20

60

100

10

12

150

3
14 Q [m /h] 16

250 Q [l/min]

200

ISO 9906:2012 - Grade 3B

10

20

30

20

50 Q [Imp gpm]

40
40

60

Q [US gpm]

140

H [m]

H [ft]

H [m]

50

Q [US gpm]

120

10SV11

50 Q [Imp gpm]

40
40

H [ft]

06645_B_CH

400

120

100

06646_B_CH

300
100
80

300
80
200

60

200

60
40
40
100

100
20

20

NPSH [ft]

0
3

NPSH [m]

NPSH [ft]

0
3

NPSH [m]

6
2

0
0
0

4
50

6
100

10
150

12
200

14 Q [m /h] 16
250 Q [l/min]

0
0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

144

4
50

6
100

10
150

12
200

14 Q [m /h] 16
250 Q [l/min]

06648_B_CH

06647_B_CH

e-SVH
HYDRO
VARTM
HYDROV

0
3

10SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
0

ISO 9906:2012 - Grade 3B

10

20

30

20

10SV20

50 Q [Imp gpm]

40
40

60

Q [US gpm]

20

30

20

50 Q [Imp gpm]

40
40

60

Q [US gpm]

H [m]

H [m]

10

300

H [ft]

200

ISO 9906:2012 - Grade 3B

H [ft]

10SV15

600

250

800

500

150

200
400

600

150

100
300

400
100
200
50
200
50

6
2

0
2

50

100

10
150

14 Q [m /h] 16

200

10SV21
0

12

06649_B_CH

250 Q [l/min]

ISO 9906:2012 - Grade 3B

10

20

30

20

50 Q [Imp gpm]

40
40

60

Q [US gpm]

H [m]

H [ft]

300

250

800

200
600

150
400
100

200
50

NPSH [ft]

NPSH [m]

0
3

6
2
4

0
0
0

4
50

6
100

10
150

12
200

14 Q [m /h] 16
250 Q [l/min]

06651_B_CH

0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

145

4
50

6
100

10
150

12
200

14 Q [m /h] 16
250 Q [l/min]

06650_B_CH

e-SVH
HYDRO
VARTM
HYDROV

NPSH [ft]

0
3

NPSH [m]

NPSH [m]

0
3

NPSH [ft]

100

15SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
0
0

20
20

15SV03

ISO 9906:2012 - Grade 3B


40

60

40

60

80
80

Q [Imp gpm]

100

100
120

0
Q [US gpm]

20

40

60

40

60

80
80

Q [Imp gpm]

100
120 Q [US gpm]

100

160

H [m]

H [m]

20

50

H [ft]

30

ISO 9906:2012 - Grade 3B

60

H [ft]

15SV02

140

25
40
50

120
20
40

100

30

15

80
30
20
60

10
20
40
10
5

10
20

15

NPSH [ft]

NPSH [m]

15

0
6

NPSH [ft]

NPSH [m]

4
10

10

2
5

15

100

20

200

300

400

15SV05
0
0

Q [m3/h] 30
Q [l/min] 500

0
0

40

60

40

60

80
80

Q [Imp gpm]

100

20

200

300

400

Q [m3/h] 30
Q [l/min] 500

ISO 9906:2012 - Grade 3B

20
20

25

40

60

40

60

80
80

Q [Imp gpm]

100
120 Q [US gpm]

100

120

H [m]

H [ft]

H [m]

15

100

0
Q [US gpm]

80

10

15SV07

100
120

ISO 99062012 - Grade 3B

20
20

25

H [ft]

10

06653_B_CH

0
0

06652_B_CH

200
100
300

60
80

150

200

60

40
100

40
100

20
50
20

15

NPSH [ft]

15

0
6

NPSH [m]

NPSH [ft]

0
6

NPSH [m]

4
10

10

2
5

0
0
0

10
100

15
200

20
300

25
400

Q [m3/h] 30
Q [l/min] 500

0
0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

146

10
100

15
200

20
300

25
400

Q [m3/h] 30
Q [l/min] 500

06655_B_CH

06654_B_CH

e-SVH
HYDRO
VARTM
HYDROV

0
6

15SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
15SV09
0
0

20
20

40

60

40

60

80
80

Q [Imp gpm]

100

100

120 Q [US gpm]

20
20

40

60

40

60

80
80

Q [Imp gpm]

100
120 Q [US gpm]

100

H [m]

H [ft]

500
140

400

120

600

H [ft]

200

160

H [m]

ISO 9906:2012 - Grade 3B

15SV13

ISO 9906:2012 - Grade 3B

500

150

100

400
300

80

100
300
200

60

200
40

50
100
100

20

15
4

10

10

2
5

10

15

100

20

200

300

15SV17
0
0

400

Q [m3/h] 30
Q [l/min] 500

40

60

40

60

80
80

Q [Imp gpm]

100
120 Q [US gpm]

100

H [m]

H [ft]

300

250

800

200
600

150
400
100

200
50

15

NPSH [ft]

NPSH [m]

0
6

4
10
2
5

0
0
0

10
100

15
200

20
300

25
400

Q [m3/h] 30
Q [l/min] 500

06658_B_CH

0
0

ISO 9906:2012 - Grade 3B

20
20

25

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

147

10
100

15
200

20
300

25
400

Q [m3/h] 30
Q [l/min] 500

06657_B_CH

0
0

06656_B_CH

e-SVH
HYDRO
VARTM
HYDROV

NPSH [ft]

NPSH [ft]

15

0
6

NPSH [m]

NPSH [m]

0
6

22SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT

20
20

40
40

60
60

80
80

100

100

Q [Imp gpm]
120

140

H [ft]

Q [US gpm]
140
160

120

16

ISO 9906:2012 - Grade 3B

20
20

40
40

60
60

80
80

100

100

Q [Imp gpm]
140

120

120

140

Q [US gpm]
160

50

50

160

H [m]

H [m]

22SV03

ISO 9906:2012 - Grade 3B

H [ft]

22SV01

14

140
40
40

12

120

10

100

30
30

80
20

20

60

40
10

10
2

20

15

NPSH [ft]

NPSH [m]

15

0
6

NPSH [ft]

NPSH [m]

4
10

10

2
5

20
200

400

22SV04

40
40

60
60

80
80

100

100

120

140

Q [US gpm]
160

200

300

400

Q [m3/h] 40

500

600

Q [l/min]

ISO 9906:2012 - Grade 3B

20
20

30

40
40

60
60

80
80

100

100

Q [Imp gpm]
140

120

120

140

160

Q [US gpm]

80
250

H [m]

H [m]

70

100

20

22SV05

Q [Imp gpm]
140

120

10

ISO 9906:2012 - Grade 3B

20
20

600 Q [l/min]

0
0

H [ft]

Q [m3/h] 40

30

06660_B_CH

10

H [ft]

0
0

06659_B_CH

200

60

200

60
50
150

150

40
40
100

30

100
20
20
50

50

10

15

NPSH [ft]

15

0
6

NPSH [m]

NPSH [ft]

0
6

NPSH [m]

4
10

10

2
5

0
0
0

10
100

20
200

300

400

30

Q [m3/h] 40

500

600

Q [l/min]

0
0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

148

10
100

20
200

300

400

30

Q [m3/h] 40

500

600

Q [l/min]

06662_B_CH

06661_B_CH

e-SVH
HYDRO
VARTM
HYDROV

0
6

22SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
22SV07
0
0

20
20

22SV10

ISO 9906:2012 - Grade 3B


40
40

60
60

80
80

100

100

Q [Imp gpm]
140

120

120

140

160

Q [US gpm]

120

ISO 9906:2012 - Grade 3B

20
20

40
40

60
60

80
80

100

100

Q [Imp gpm]
140

120

120

140

160

Q [US gpm]

H [ft]

H [m]

H [m]

H [ft]

180

160

500

100
140

300
80

400

120

100
300

200

60

80

40

200

60
100
40

100

20
20

15
4

10

10

2
5

10
100

200

300

400

22SV14
0
0

Q [m3/h] 40

500

600

Q [l/min]

0
0

40
40

60
60

80
80

100

100

120

140

160

Q [US gpm]

250

200

300

400

Q [m3/h] 40

500

600

Q [l/min]

ISO 9906:2012 - Grade 3B

20
20

30

40
40

60
60

80
80

100

100

Q [Imp gpm]
140

120

120

140

160

Q [US gpm]

300

H [m]

H [ft]

800

H [m]

100

20

22SV17

Q [Imp gpm]
140

120

10

ISO 9906:2012 - Grade 3B

20
20

30

H [ft]

20

06665_B_CH

0
0

06664_B_CH

250

800

200
600
200

600

150
150

400

400

100
100
200

200

50
50

15

NPSH [ft]

NPSH [ft]

15

0
6

NPSH [m]

NPSH [m]

0
6

4
10

10

2
5

10
100

20
200

300

400

30

Q [m3/h] 40

500

600

Q [l/min]

0
0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

149

10
100

20
200

300

400

30

Q [m3/h] 40

500

600

Q [l/min]

06667_B_CH

0
0

06666_B_CH

e-SVH
HYDRO
VARTM
HYDROV

NPSH [ft]

NPSH [ft]

15

0
6

NPSH [m]

NPSH [m]

0
6

33SVH SERIES
OPERA
TING CHARACTERISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTICS
AT
33SV1
50
50

150

100

200 Q [US gpm]

150

25

ISO 9906:2012 - Grade 3B

50

100

50

150

100

Q [Imp gpm]
200 Q [US gpm]

150

50

160

H [m]

80

H [ft]

H [m]

100

Q [Imp gpm]

H [ft]

0
0

33SV2

ISO 9906:2012 - Grade 3B

20

140
40

60

120

15

100

30

40

80

10

20
60

20

40

10
20

10

NPSH [ft]

40

NPSH [m]

0
15

NPSH [ft]

NPSH [m]

40
10

30

30

20

20

5
10

10

10
100

20
200

300

30
400

500

33SV3

700
Q [l/min]

800

0
0
0

50

100

50

150

100

Q [Imp gpm]

100

20
200

300

30
400

50

80

Q [m350
/h]

40

500

600

700

800
Q [l/min]

ISO 9906:2012 - Grade 3B

200 Q [US gpm]

150

10

33SV4

ISO 9906:2012 - Grade 3B

0
0

600

Q [m350
/h]

40

06669_B_CH

0
0

06668_B_CH

100

50

150

100

Q [Imp gpm]
200 Q [US gpm]

150

60

200

H [m]

H [ft]

250
70

300

H [ft]

H [m]

100

80
250

200

60
50
150

150
40
40
100

100

30

20
50

20
50

NPSH [ft]

40

NPSH [m]

0
15

40

NPSH [ft]

10
15

NPSH [m]

10

10

30

30

20

20
5

10

10

0
0
0

10
100

20
200

300

30
400

500

Q [m350
/h]

40
600

700

800

Q [l/min]

0
0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

150

10
100

20
200

300

30
400

500

3
Q [m50
/h]

40
600

700

800
Q [l/min]

06671_B_CH

06670_B_CH

e-SVH
HYDRO
VARTM
HYDROV

0
15

33SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
0

50

33SV6

ISO 9906:2012 - Grade 3B


100

50

150

100

Q [Imp gpm]

200 Q [US gpm]

150

ISO 9906:2012 - Grade 3B


50

50

150

100

Q [Imp gpm]
200 Q [US gpm]

150

160

140

400

120

500

H [m]

H [m]

H [ft]

140

100

H [ft]

33SV5

400

120
100
300
100

300

80
80
200

60

200

60
40
40
100

100

20

20

10

40
10

30

30

20

20

5
10

10
100

20
200

300

30
400

500

33SV7

700

800
Q [l/min]

50

100

100

Q [Imp gpm]
200 Q [US gpm]

150

H [ft]

50

150

H [m]

180

160
500
140
400

120

100
300
80

200

60

40
100
20

40

NPSH [ft]

NPSH [m]

0
15

10
30

20
5
10

0
0
0

10
100

20
200

300

30
400

500

3
Q [m50
/h]

40
600

700

800
Q [l/min]

06674_B_CH

0
0

ISO 9906:2012 - Grade 3B

0
0

600

3
Q [m50
/h]

40

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

151

10
100

20
200

300

30
400

500

3
Q [m50
/h]

40
600

700

800
Q [l/min]

06673_B_CH

0
0

06672_B_CH

10

e-SVH
HYDRO
VARTM
HYDROV

NPSH [ft]

NPSH [ft]

40

0
15

NPSH [m]

NPSH [m]

0
15

46SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
46SV1
0

50

46SV2

ISO 9906:2012 - Grade 3B


100

50

150

100

150

250

Q [US gpm]
250
300

200
200

Q [Imp gpm]

ISO 9906:2012 - Grade 3B


50

100

50

150

100

150

200
200

Q [Imp gpm]

250

250

Q [US gpm]
300

60

H [ft]

30

25

50

H [m]

H [ft]

H [m]

80

150

40

20
60

100

30

15
40

20

10

50
20
10

0
15

NPSH [m]

40

NPSH [ft]

NPSH [m]

10

40
10

30

30

20

20

5
10

10

10

20

200

30
400

40
600

800

46SV3

1000

Q [l/min]

0
0

50

100

50

150

100

150

200
200

Q [Imp gpm]

10

20

200

30
400

40
600

250

Q [US gpm]
250
300

3
60 Q [m /h] 70

50
800

46SV4

ISO 9906:2012 - Grade 3B

0
0

3
60 Q [m /h] 70

50

06676_B_CH

0
0

06675_B_CH

1000

Q [l/min]

ISO 9906:2012 - Grade 3B


50

100

50

150

100

150

200

Q [Imp gpm]

250

Q [US gpm]
250
300

200

120

100

H [ft]

300
100

H [m]

80

H [m]

H [ft]

250

60

200

300

80

200

60
150
40
40
100

100
20

0
15

40

10

40

NPSH [ft]

20

NPSH [m]

50

NPSH [ft]

0
15

NPSH [m]

10
30

30

20

20

5
10

0
0
0

10
200

20

30
400

40
600

50
800

3
60Q [m /h]

1000

70

Q [l/min]

0
0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

152

10
200

20

30
400

40
600

50
800

3
60Q [m /h]

1000

70

Q [l/min]

06678_B_CH

10

06677_B_CH

e-SVH
HYDRO
VARTM
HYDROV

0
15

NPSH [ft]

46SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
46SV6

ISO 9906:2012 - Grade 3B

0
0

50

100

50

150

100

150

200

Q [Imp gpm]

250

Q [US gpm]
250
300

200

180

160

H [ft]

500

H [m]

140

400

120

100
300
80

200

60

40
100
20

e-SVH
HYDRO
VARTM
HYDROV

40

NPSH [ft]

NPSH [m]

0
15

10
30

20
5
10

0
0
0

10
200

20

30
400

40
600

50
800

3
60Q [m /h]

1000

70

Q [l/min]

06679_B_CH

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

153

66SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
66SV1
0

100

66SV2

ISO 9906:2012 - Grade 3B


200

100

300

200

300

Q [US gpm]

Q [Imp gpm]

400

35

ISO 9906:2012 - Grade 3B

50
50

100
100

150
150

200
200

250

250

300

Q [Imp gpm]
300
350
350

400 Q [US gpm]

70

100

200

60

25

50

80

H [m]

H [ft]

H [m]

30

H [ft]

150

20

40

60
15

100

30
40

10

20
50
20
10

40

NPSH [m]

0
15

NPSH [ft]

NPSH [m]

10

40
10

30

30

20

20

5
10

10

20
200

40
400

600

800

1000

66SV3
0
0

1200

1400

100
1600
Q [l/min]

0
0
0

100
100

150
150

200
200

250

250

300

Q [Imp gpm]
300
350
350

400

20
200

40
400

600

Q [US gpm]

100

800

1000

1200

1400

100
1600
Q [l/min]

ISO 9906:2012 - Grade 3B

50
50

3
80 Q [m /h]

60

66SV4

ISO 9906:2012 - Grade 3B

50
50

3
80 Q [m /h]

60

06681_B_CH

0
0

06680_B_CH

100
100

150
150

200
200

250

250

300

Q [Imp gpm]
350

300
350

400 Q [US gpm]

140
300
400

H [m]

250

H [ft]

H [m]

120
80

100
300
200
80

H [ft]

60

150

200

60
40
100

40
100

20

0
15

40

10

40

NPSH [ft]

20

NPSH [m]

50

NPSH [ft]

0
15

NPSH [m]

10
30

30

20

20

5
10

0
0
0

20
200

40
400

600

3
80 Q [m /h]

60
800

1000

1200

1400

100
1600
Q [l/min]

0
0
0

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

154

20
200

40
400

600

3
80 Q [m /h]

60
800

1000

1200

1400

100
1600
Q [l/min]

06683_B_CH

10

06682_B_CH

e-SVH
HYDRO
VARTM
HYDROV

0
15

NPSH [ft]

92SVH SERIES
OPERA
TING CHARACTE
RISTIC
S A
T 30..50 Hz
OPERATING
CHARACTERISTIC
RISTICS
AT
92SV1
0
0

92SV2

ISO 9906:2012 - Grade 3B


100

200

100

300

200

300

400
400

Q [Imp gpm]

500

Q [US gpm]
500
600

100

200

100

300

200

300

400

Q [Imp gpm]

500

Q [US gpm]
500
600

400

80

H [m]
70

100

30

250

H [ft]

H [m]

H [ft]

35

ISO 9906:2012 - Grade 3B

200

60
25

80
50
150

20
60

40

15
100

30

40
10

20
50

20
5

10

10

40
10

30

30

20

20

20

40

60

500

80

1000

100
1500

92SV3
0
0

120

Q [m3/h]

2000

0
06684_B_CH

10

140

Q [l/min]

0
0

ISO 9906:2012 - Grade 3B


100

200

100

300

200

300

400

Q [Imp gpm]

500

Q [US gpm]
500
600

400

H [ft]

H [m]

120

100

300
80

200

60

40
100
20

40

NPSH [ft]

NPSH [m]

0
15

10
30

20
5
10

0
0
0

20

40
500

60
1000

80

100
1500

120 Q [m /h]140
2000

Q [l/min]

06686_B_CH

The curves show the performance with one pump running to the minimum and maximum speed.
These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/s.

155

20

40
500

60
1000

80

100
1500

3
120 Q [m /h] 140

2000

Q [l/min]

06685_B_CH

10

e-SVH
HYDRO
VARTM
HYDROV

NPSH [ft]

NPSH [ft]

40

0
15

NPSH [m]

NPSH [m]

0
15

156

e-SVH
HYDRO
VARTM
HYDROV

4-POLE
(50/60 Hz)

4-POLE VERSIONS
(50/60 Hz)

157

e-SV SERIE - 4-POLE VERSION


50/60 Hz
Background and context
In the building services market, reducing the level of noise
of the pumping equipment is one of the main goals of
architects and facilities managers to bring more comfort
to our life. In water boosting systems or in cooling and
heating installations, often architects and contractors are
looking at quiet operational systems. Therefore Lowara
has developed the e-SVTM series with 4 pole versions: a
pump which delivers a quiet and reliable solution to the
most noise sensitive applications.

Benefits of e-SVTM 4 pole

Low level of noise


noise: e-SVTM 4 pole, by reducing the
speed of the pump by 50% allows delivering very quiet
operation.

4-POLE
(50/60 Hz)

Wide range of performances


performances: e-SV TM 4 pole is
available from 1SV to 125SV, from 0,25 kW to 15 kW.
The efficiency values of e-SVTM 4 pole are comparable to
the e-SVTM series with 2 poles.
Increased performance with HYDRO
VARTM: e-SVTM
HYDROV
TM
4 pole combined with HYDROVAR , the variable speed Special features / product benefits
driver developed by Lowara, allows an additional reduction - Hard material intermediate bush bearing
of the noise of the pumping system. HYDROVARTM, by (Tungsten Carbide) to improve life and ability to withstand
smoothing the ramping up and down of the pump, heavy duty application on all sizes.
reduces the speed of the water in the piping and as a - IE2 standard motors
motors, 3-phase, 4-pole from 0,75 kW
consequence the noise made by the full installation.
to 15 kW.
VARTM drive available on all models to
- HYDRO
HYDROV
allow e-SVTM 4 pole into an intelligent, variable
Code identification
speed system
system. Ideal for single pumping solution or
e-SVTM 4 pole version is identified with a 4 in the
TM
multiple pumping set solution (up to 8 pumps).
product codification of the whole e-SV range.
- Standard mechanical seal (EN12756) fitted on all
models. Easy to replace without removing
4T
Example: 3SV11F0024
the motor from 5,5 kW up.
4 = 4 pole version.
- i-ALERTTM device to reduce life cycle costs by increasing
Mean time between Failures (MTBF).

Special configurations
e-SVTM 4 pole offers the same range of configuration of the
standard e-SVTM series.
- Materials used: see the Materials section.
- Options for mechanical seals and gaskets:
see the mechanical seals and gaskets section.
- Options for motors and configuration:
see the motors section.
- HYDROVARTM system included: see the e-SVH section
(e-SVTM with HYDROVARTM).

158

e-SV SERIES
HYDRA
ULIC PERFORMANCE RANGE A
T 50 Hz, 4-POLE
HYDRAULIC
AT
1450 [rpm]

e-SV

ISO 9906:2012 - Grade 3B

10

Q [Imp gpm]

100

10

Q [US gpm]

100

80

H [ft]

H [m]

250
70

200

60

50
150

4-POLE
(50 Hz)

40

100

125SV

92SV

66SV

46SV

33SV

22SV

15SV

10SV

5SV

1SV

20

3SV

30

50

10

0
100

5SV

33SV 46SV 66SV 92SV 125SV


10SV 15SV 22SV

3SV
60

1SV

40
20

1
10

10
100

159

Q [m3/h]
Q [l/min]

100
1000

06094_C_CH

[%]

80

1, 3, 5, 10, 15, 22SV SERIES


TABELLA DI PRESTAZIONI IDRAULICHE SERIE 1SV 3SV 5SV 4p 50 Hz
HYDRA
ULIC PERFORMANCE T
ABLE A
T 50 Hz, 4-POLE
HYDRAULIC
TABLE
AT
PUMP

RATED

TYPE

POWER

4-POLE
(50 Hz)

kW

1SV02..4
0,25
1SV05..4
0,25
1SV08..4
0,25
1SV11..4
0,25
1SV15..4
0,25
1SV19..4
0,25
1SV22..4
0,25
1SV27..4
0,25
1SV30..4
0,25
1SV34..4
0,25
1SV37..4
0,25
3SV02..4
0,25
3SV05..4
0,25
3SV08..4
0,25
3SV11..4
0,25
3SV14..4
0,25
3SV19..4
0,25
3SV23..4
0,25
3SV27..4
0,37
3SV33..4
0,37
5SV03..4
0,25
5SV06..4
0,25
5SV09..4
0,25
5SV12..4
0,25
5SV15..4
0,37
5SV18..4
0,37
5SV21..4
0,37
5SV25..4
0,55
5SV28..4
0,55
5SV33..4
0,75
TABELLA
DI

Q = DELIVERY
l/min 0

5,84

10

12,5

15

18

20

22

25

30

36

50

60

70,83

3
m /h 0

0,4

0,6

0,8

0,9

1,1

1,2

1,3

1,5

1,8

2,2

3,0

3,6

4,2

3,7
7,0
10,1
12,6
15,0
18,4
20,7
23,3
29,2
33,1

2,7
5,0
7,1
8,7
10,1
12,5
13,7
15,1
20,0
22,3

H = TOTAL HEAD IN METRES OF COLUMN OF WATER

HP

0,34
3,1
3,1
0,34
7,7
7,8
0,34
12,2
12,4
0,34
16,7
16,9
0,34
22,6
22,9
0,34
28,8
29,4
0,34
33,2
33,8
0,34
40,1
40,4
0,34
44,4
44,6
0,34
50,0
50,2
0,34
54,2
54,2
0,34
3,8
0,34
9,5
0,34
15,1
0,34
20,6
0,34
26,1
0,34
33,3
0,34
42,2
0,5
49,7
0,5
60,2
0,34
5,7
0,34
11,3
0,34
16,8
0,34
22,2
0,5
27,5
0,5
33,1
0,5
38,4
0,75
45,3
0,75
51,7
1
60,5
PRESTAZIONI

3,0
7,4
11,7
16,0
21,6
27,7
31,7
38,0
41,9
46,9
50,5
3,8
9,5
14,9
20,3
25,8
32,6
40,9
48,5
58,3

2,8
6,9
10,9
14,9
20,0
25,6
29,3
35,2
38,6
43,1
46,4
3,8
9,4
14,7
20,0
25,3
32,0
40,1
47,5
57,0

2,5
6,2
9,8
13,3
17,8
22,8
26,0
31,1
34,0
37,9
40,6
3,7
9,2
14,4
19,6
24,8
31,3
39,0
46,3
55,4

2,1
5,0
7,9
10,7
14,3
18,2
20,6
24,3
26,5
29,3
31,2
3,6
8,9
14,0
18,9
23,9
30,0
37,4
44,4
53,0

IDRAULICHE SERIE

1,7
4,0
6,3
8,5
11,3
14,4
16,2
18,6
20,1
22,1
23,4
3,5
8,6
13,6
18,3
23,1
29,0
36,0
42,9
51,0
6
10,9
16,1
21,1
25,9
31,3
36,1
42,2
49,1
57,2
10SV

3,4
3,2
2,7
2,0
8,3
7,8
6,7
4,8
13,1
12,2
10,4
7,4
17,7
16,5
13,9
9,8
22,2
20,7
17,3
12,0
27,9
25,8
21,5
14,5
34,5
31,8
26,1
17,2
41,1
38,0
31,4
21,0
48,7
44,8
36,5
23,7
6
5
5
5,1
10,8
10,7
10,4
9,9
16,0
15,7
15,3
14,6
20,9
20,5
19,8
18,8
25,6
25,2
24,2
22,9
31,0
30,4
29,3
27,8
35,7
35,0
33,6
31,7
41,6
40,8
39,1
36,7
48,6
47,8
46,1
43,7
56,6
53,4
15SV55,5
22SV
4p 50,5
50

4,4
8,5
12,3
15,6
18,8
22,9
26,0
29,7
36,2
41,4
Hz

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A)

PUMP

RATED

TYPE

POWER

kW

1-5sv-4p50-en_b_th

Q = DELIVERY
l/min 0

41,7

50

66,67

85

91,7

116,6

135

165

175

200

215

230

241,6

m3/h 0

2,5

3,0

4,0

5,1

5,5

7,0

8,1

9,9

10,5

12,0

12,9

13,8

14,5

4,8

H = TOTAL HEAD IN METRES OF COLUMN OF WATER

HP

10SV03..4

0,55 0,75

9,0

8,4

8,2

7,7

6,7

6,3

4,3

10SV04..4

0,55 0,75

12,0

11,2

11,0

10,2

9,0

8,5

5,7

10SV06..4

0,55 0,75

17,9

16,7

16,2

15,1

13,3

12,5

8,5

10SV08..4

0,55 0,75

23,6

21,9

21,3

19,7

17,2

16,1

10,7

10SV10..4

0,55

28,9

26,6

25,8

23,7

20,6

19,3

12,7

10SV13..4

0,75

37,9

34,4

33,3

30,4

26,0

24,1

15,2

10SV15..4

0,75

1,0

44,1

40,4

39,1

35,9

31,0

28,9

18,6

10SV17..4

1,1

1,5

49,6

45,0

43,5

39,7

34,1

31,6

19,7

10SV19..4

1,1

1,5

55,2

49,7

47,9

43,6

37,2

34,4

21,1

10SV21..4

1,1

1,5

62,8

58,9

57,4

53,3

46,9

43,9

29,7

15SV03..4

0,55 0,75

10,7

10,0

9,7

9,5

8,9

8,3

7,0

6,5

15SV05..4

0,55 0,75

17,8

16,3

15,8

15,5

14,4

13,4

11,2

10,4

4,9
7,7

15SV07..4

0,75 1,00

24,6

22,2

21,3

21,0

19,5

18,0

15,0

13,7

10,0

15SV09..4

1,1

1,50

32,8

30,8

29,9

29,6

27,8

26,1

22,4

20,9

16,4

15SV11..4

1,1

40,1

37,2

36,2

35,7

33,6

31,5

27,1

25,2

19,7

15SV13..4

1,5

47,6

44,5

43,3

42,7

40,3

38,0

32,7

30,6

24,1

15SV15..4

1,5

2,0

54,8

51,1

49,7

49,1

46,3

43,6

37,5

35,0

27,4

15SV17..4

2,2

62,5

58,7

57,2

56,6

53,5

50,5

43,8

41,0

32,5

14,9

13,6

12,9

12,3

10,9

10,3

8,6

7,4

6,0

22SV06..4

1,1

1,5

22,6

20,8

19,8

18,9

16,9

16,0

13,6

11,9

9,9

8,2

22SV08..4

1,1

1,5

30,8

29,0

27,9

26,8

24,3

23,3

20,2

17,9

15,4

13,1

22SV10..4

1,5

38,6

36,5

35,2

33,8

30,8

29,5

25,7

22,9

19,7

17,0

22SV12..4

2,2

46,0

43,4

41,8

40,2

36,5

35,0

30,3

26,9

23,0

19,7

22SV14..4

2,2

53,9

51,4

49,6

47,8

43,6

41,8

36,5

32,6

28,1

24,2

22SV17..4

65,3

61,9

59,7

57,4

52,2

50,1

43,5

38,8

33,3

28,5

22SV04..4

0,55 0,75

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A)

160

10-22sv-4p50-en_b_th

33, 46, 66, 92, 125SV SERIES


TABELLA DI PRESTAZIONI IDRAULICHE SERIE 33-92SV 4 poli 50 Hz
HYDRA
ULIC PERFORMANCE T
ABLE A
T 50 Hz, 4-POLE
HYDRAULIC
TABLE
AT
PUMP

RATED

TYPE

POWER

Q = DELIVERY
l/min 0

125

150

200

250

300

333

375

450

500

600

700

750

800

900

1000

m3/h 0

7,5

12

15

18

20

22,5

27

30

36

42

45

48

54

60

H = TOTAL HEAD METRES COLUMN OF WATER

kW

HP

33SV3/2A..4

1,1

1,5

14,4 13,7 13,4 12,4 10,9

33SV4/1A..4

1,1

1,5

21,8 20,4 19,9 18,7 16,9 14,4 12,3

33SV5..4

1,5

29,4 27,5 26,9 25,5 23,4 20,4 17,9

33SV6..4

2,2

35,9 33,8 33,2 31,5

33SV7..4

2,2

41,6 39,1 38,3 36,2 33,2 29,1 25,6

33SV8..4

47,9 45,2 44,3

33SV9..4

53,3 50,2 49,2 46,7

33SV10..4

33SV11..4

33SV12..4

33SV13..4

29

42

7,3

25,5 22,5

38,8 34,2 31,3


43

37,9 33,4

59 55,4

54

51

47

41,5 36,5

5,5

65,7 62,2

61

58

54

48

42,3

5,5

71,5 67,6

66

63

58

52

45,7

5,5

77,2

72

68

63

55

49

46SV2..4

1,1

1,5

13

46SV3..4

1,5

19,8

46SV4..4

2,2

26,3

46SV5..4

2,2

32,6

29,6 28,5

46SV6..4

39,3

35,9 34,6 32,9 31,5 29,3 24,1 19,5

46SV7..4

45,5

41,5

46SV8..4

5,5

52,5

48,3 46,6 44,4 42,5 39,6 32,6 26,5

73

11,8 11,3 10,7 10,1

7,5

5,9

17,8 17,1 16,2 15,4 14,2 11,5

9,2

24

9,4

23,1 21,9 20,9 19,4 15,8 12,7

40

27

25,8 23,9 19,4 15,5

37,9 36,2 33,6 27,4

22

5,5

58,9

53,9

52

50

46SV10..4

5,5

7,5

66,2

61

59

56

47,4 44,1 36,2 29,2


54

50,5

42

34,5

46SV11..4

5,5

7,5

72,6

66,9

65

62

59

55,2

46

37,6

46SV12..4

5,5

7,5

78,9

72,7

70

67

64

59,8

50

40,4

66SV1..4

1,1

1,5

7,3

6,4

6,1

5,8

5,4

5,1

4,4

3,4

2,7

66SV2..4

1,5

14,8

13,5 13,1 12,9 12,5 11,8 11,2

9,9

8,2

7,2

66SV3..4

2,2

22,3

20,3 19,7 19,3 18,8 17,7 16,9 14,9 12,3 10,7

66SV4..4

29,7

27,1 26,4 25,8 25,1 23,7 22,6

66SV5..4

5,5

37,5

34,4 33,5 32,9

32

66SV6..4

5,5

44,7

40,9 39,8

39

38

36

66SV7..4

5,5

7,5

52,8

48,5 47,3

46

45

43

41

36

30,5 26,8

66SV8..4

5,5

7,5

60,1

55,1 53,7

53

51

49

46

41

34,3 30,2

92SV1..4

1,1

1,5

8,3

6,4

6,1

5,6

5,1

4,9

4,6

3,8

2,8

92SV2..4

2,2

16,3

14,3 13,6 13,1 12,1 11,1 10,5

10

8,6

92SV3..4

24,4

21,3 20,1 19,4 17,8 16,3 15,5 14,6 12,7 10,2

92SV4..4

5,5

32,9

28,9 27,4 26,4 24,4 22,4 21,3 20,2 17,5 14,3

92SV5..4

5,5

7,5

41,6

36,7 34,9 33,6 31,1 28,6 27,2 25,8 22,6 18,6

92SV6..4

5,5

7,5

49,5

43,6

41

40

37

34

92SV7..4

7,5

10

58

51,2

49

47

43

40

38

35,9 31,4 25,7

92SV8..4

7,5

10

65,9

58

55

53

49

45

43

40,5 35,3 28,8

20

4-POLE
(50 Hz)

46SV9..4

16,6 14,5

30,3 28,9 25,7 21,4 18,8


34,1 30,2 25,1 21,9

TABELLA DI PRESTAZIONI IDRAULICHE SERIE 125SV 4p 50 Hz

32,2 30,5 26,6 21,7

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - A

PUMP

RATED

TYPE

POWER

125SV1..4
125SV2..4
125SV3/3B..4
125SV4/4B..4
125SV5/5A..4
125SV6..4
125SV7..4
125SV8..4

kW

HP

1,1
2,2
2,2
3
4
5,5
7,5
7,5

1,5
3
3
4
5,5
7,5
10
10

33-92sv-4p50-en_b_th

Q = DELIVERY
l/min 0

250

300

375

450

500

600

708

850

950

1000

1075

1150

1333

m3/h 0

15,0

18,0

22,5

27,0

30,0

36,0

42,5

51,0

57,0

60,0

64,5

69,0

80,0

3,6
8,2
9,5
12,6
18,2
24,7
28,8
32,9

3,2
7,6
8,4
11,2
16,5
22,8
26,7
30,5

2,8
6,9
7,2
9,6
14,7
20,8
24,2
27,7

1,5
4,9
3,6
4,9
9,2
14,7
17,2
19,6

H = TOTAL HEAD IN METRES OF COLUMN OF WATER

6,9
13,5
17,5
23,3
31,4
40,4
47,1
53,8

5,2
11,1
14,1
18,8
25,6
33,3
38,8
44,4

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A)

161

5,0
10,6
13,4
17,9
24,4
31,9
37,2
42,5

4,7
10,1
12,6
16,7
23,0
30,3
35,3
40,4

4,2
9,3
11,2
15,0
20,9
27,8
32,5
37,1

3,8
8,6
10,1
13,5
19,2
25,8
30,1
34,4

125sv-4p50-en_b_th

4-POLE
(50 Hz)

1SV SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 4-POLE
AT

DIMENSIONI E PESI SERIE 1SV 4 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

1SV02..4..
1SV05..4..
1SV08..4..
1SV11..4..
1SV15..4..
1SV19..4..
1SV22..4..
1SV27..4..
1SV30..4..
1SV34..4..
1SV37..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25

71
71
71
71
71
71
71
71
71
71
71

278
318
378
438
518
598
658
758
818
898
958

231
231
231
231
231
231
231
231
231
231
231

140
140
140
140
140
140
140
140
140
140
140

105
105
105
105
105
105
105
105
105
105
105

121
121
121
121
121
121
121
121
121
121
121

8,3
9,4
10,6
11,8
13,4
14,9
16,1
18,1
19,3
20,9
22,1

15,2
16,2
17,4
18,6
20,2
21,7
22,9
24,9
26,1
27,7
28,9
1sv-4p50-en_b_td

162

1SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1450 [rpm]

1SV
0

ISO 9906:2012 - Grade 3B


3

4
4

Q [Imp gpm]
5

Q [US gpm]
H [ft]

H [m]

60
37
34

50

150

30
27

40

22
30

100

4-POLE
(50 Hz)

19

15
20
11
50
08
10
05
02
0
60
40
kW/stage

0,00
2

20
5

1
0

0
0,0
0

0,1

0,2

0,3
5

0,4

0,5

0,6

0,7

10

0,8

0,9
15

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

163

1,0

1,1 Q [m
1,2/h] 1,3
20 Q [l/min]

NPSH [ft]

NPSH [m]

0,01

06060_B_CH

Pp [kW]

[%]

0
0,02

4-POLE
(50 Hz)

3SV SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 4-POLE
AT

DIMENSIONI E PESI SERIE 3SV 4 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

3SV02..4..
3SV05..4..
3SV08..4..
3SV11..4..
3SV14..4..
3SV19..4..
3SV23..4..
3SV27..4..
3SV33..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,37
0,37

71
71
71
71
71
71
71
71
71

278
318
378
438
498
598
678
758
878

231
231
231
231
231
231
231
231
231

140
140
140
140
140
140
140
140
140

105
105
105
105
105
105
105
105
105

121
121
121
121
121
121
121
121
121

8
9,3
10,5
11,6
12,9
14,9
16,5
18
20,4

14,9
16,8
17,3
18,4
19,6
21,6
23,2
26
28,4

3sv-4p50-en_b_td

164

3SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1450 [rpm]

3SV
0
0

4
4

ISO 9906:2012 - Grade 3B

5
5

6
7

7
8

Q [Imp
9 gpm]
10 Q [US
11 gpm]

H [ft]

H [m]

70

60

33

50

27

200

150
23
40

4-POLE
(50 Hz)

19
100

30
14
11

20

50

08
10

05
02

Pp [kW]

0,01

40

kW/stage

20
5

1
0

0
0,0
0

0,2

0,4

0,6
10

0,8

1,0

1,2

1,4

20

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

165

1,6

1,8
30

2,0

[m /h]
2,2 Q 2,4

Q [l/min]

40

NPSH [ft]

0,00
2

06061_B_CH

NPSH [m]

0
60
[%]

0
0,02

4-POLE
(50 Hz)

5SV SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 4-POLE
AT

DIMENSIONI E PESI SERIE 5SV 4 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

5SV03..4..
5SV06..4..
5SV09..4..
5SV12..4..
5SV15..4..
5SV18..4..
5SV21..4..
5SV25..4..
5SV28..4..
5SV33..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,25
0,25
0,25
0,25
0,37
0,37
0,37
0,55
0,55
0,75

71
71
71
71
71
71
71
80
80
80

293
368
443
518
593
668
743
853
928
1053

231
231
231
231
231
231
231
263
263
231

140
140
140
140
140
140
140
155
155
159

105
105
105
105
105
105
105
120
120
120

121
121
121
121
121
121
121
129
129
128

8,9
10,4
11,8
13,2
14,6
16
17,5
20
21,4
23,8

15,7
17,2
18,6
20
22,6
24
25,5
26,7
28,1
36
5sv-4p50-en_c_td

166

5SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1450 [rpm]

5SV
0

ISO 9906:2012 - Grade 3B

10

Q [Imp gpm]

15

10

20 Q [US gpm]

15

H [ft]

H [m]

70

60

33

50

28

200

150

25
40
21

4-POLE
(50 Hz)

18
100

30
15
12
20
09

50

06

10

03

Pp [kW]

0,02
0,01

60
40

kW/stage

20
5

1
0

0
0
0

2
20

3
40

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

167

4
60

Q [m /h]

Q [l/min]

5
80

NPSH [ft]

0,00
2

06062_B_CH

NPSH [m]

0
80
[%]

0
0,03

4-POLE
(50 Hz)

10SV SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 4-POLE
AT

DIMENSIONI E PESI SERIE 10SV 4 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

10SV03..4..
10SV04..4..
10SV06..4..
10SV08..4..
10SV10..4..
10SV13..4..
10SV15..4..
10SV17..4..
10SV19..4..
10SV21..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,55
0,55
0,55
0,55
0,55
0,75
0,75
1,1
1,1
1,1

80
80
80
80
80
80
80
90
90
90

389
421
485
549
613
709
773
847
911
975

263
263
263
263
263
231
231
298
298
298

155
155
155
155
155
159
159
174
174
174

120
120
120
120
120
120
120
140
140
140

129
129
129
129
129
128
128
134
134
134

16,2
17,1
18,9
20,8
22,7
25,5
27,4
29,8
31,6
33,5

22,9
23,8
25,6
27,5
29,4
37,6
39,5
47,2
49,1
50,9
10sv-4p50-en_d_td

168

10SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1450 [rpm]

10SV
0

10

ISO 9906:2012 - Grade 3B

15

10

20

Q [Imp gpm]

25

20

Q [US gpm]

30

H [ft]

H [m]

70

21

60

200

19
50
17
150
15
40

4-POLE
(50 Hz)

13

100

30
10
08
20
06

50
04
10

03

0
80

Pp [kW]

60
kW/stage
40
5

1
0

0
0
0

50

6
100

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

169

Q [m
7 /h]

8
Q [l/min]

NPSH [ft]

0,02
2

06063_C_CH

NPSH [m]

0,04

[%]

0
0,06

4-POLE
(50 Hz)

15SV SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 4-POLE
AT

DIMENSIONI E PESI SERIE 15SV 4 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

15SV03..4..
15SV05..4..
15SV07..4..
15SV09..4..
15SV11..4..
15SV13..4..
15SV15..4..
15SV17..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,55
0,55
0,75
1,1
1,1
1,5
1,5
2,2

80
80
80
90
90
90
90
100

447
543
639
745
841
937
1033
1139

263
263
231
298
298
298
298
322

155
155
159
174
174
174
174
214

120
120
120
140
140
140
140
160

129
129
128
134
134
134
134
168

18,2
20,6
23,4
26,4
29,1
31,8
34,4
38

24,9
27,3
35,5
43,8
46,5
51,8
54,4
66,8

15sv-4p50-en_d_td

170

15SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1450 [rpm]

15SV
0

10

20

10

ISO 9906:2012 - Grade 3B


30

20

30

Q [Imp gpm]

40
40

50

Q [US gpm]
H [ft]

H [m]

70

17

60

200

15
50
13

40

150

09

4-POLE
(50 Hz)

11

100

30
07
20
05

50
03

0
0,15

0
80

Pp [kW]

60
kW/stage
40
5

1
0

0
0
0

3
50

100

9
150

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

171

10

11 Q [m
12 /h] 13
Q [l/min]
200

NPSH [ft]

0,05
2

06064_C_CH

NPSH [m]

0,10

[%]

10

4-POLE
(50 Hz)

22SV SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 4-POLE
AT

DIMENSIONI E PESI SERIE 22SV 4 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

22SV04..4..
22SV06..4..
22SV08..4..
22SV10..4..
22SV12..4..
22SV14..4..
22SV17..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,55
1,1
1,1
1,5
2,2
2,2
3

80
90
90
90
100
100
100

495
601
697
793
899
995
1139

263
298
298
298
322
322
353

155
174
174
174
214
214
214

120
140
140
140
160
160
160

129
134
134
134
168
168
168

19,3
22,4
25,1
27,8
31,3
34
38

26
39,8
42,5
47,8
60,1
62,8
70

22sv-4p50-en_b_td

172

22SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1450 [rpm]

22SV
0

10

20

10

ISO 9906:2012 - Grade 3B

30

20

30

40
40

50

50

Q [Imp gpm]

60

Q [US70gpm]
H [ft]

H [m]

70
17
200

60

14
50
150

12
40

100

08

30

4-POLE
(50 Hz)

10

06
20
50

04
10

0
80

Pp [kW]

0,15

40

kW/stage

20
5

1
0

0
0
0

3
50

100

9
150

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

173

10

11

Q [m 15
/h]
14

12

13

200

Q [l/min]

250

16

NPSH [ft]

0,05
2

06065_B_CH

NPSH [m]

0,10

60

[%]

0
0,20

4-POLE
(50 Hz)

33SV SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 4-POLE
AT

DIMENSIONI E PESI SERIE 33SV 4 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

33SV3/2A..4..
33SV4/1A..4..
33SV5..4..
33SV6..4..
33SV7..4..
33SV8..4..
33SV9..4..
33SV10..4..
33SV11..4..
33SV12..4..
33SV13..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

1,1
1,1
1,5
2,2
2,2
3
3
3
4
4
4

90
90
90
100
100
100
100
100
112
112
112

639
714
789
864
939
1014
1089
1164
1239
1314
1389

298
298
298
322
322
353
353
353
398
398
398

174
174
174
214
214
214
214
214
214
214
214

164
164
164
164
164
164
164
164
164
164
164

134
134
134
168
168
168
168
168
168
168
168

16
16
16
16
16
16
16
16
16
16
16

60
64
68
72
75
79
83
87
96
100
103

78
82
91
101
104
111
115
119
150
154
157

33sv-4p50-en_b_td

174

33SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1450 [rpm]

33SV
0

20

ISO 9906:2012 - Grade 3B

40

20

Q [Imp gpm]

60

40

80 Q [US gpm]

60

75

13

70

12

65

11

250

H [ft]

H [m]

80

200

60
10
55
9
50
8
40

35

30

4-POLE
(50 Hz)

150

45

100

25
4/1A

20
15

50

3/2A

10

0
80

0,3

60

P2 1

0,2

kW/stage

[%]

0
0,4

P2 /1

40
8

1
0
0
0

4
50

6
100

10
150

12
200

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

175

14

16
250

18
300

0
3
Q [m /h]
20
Q [l/min]
350

NPSH [ft]

0,1
3

05131_D_CH

NPSH [m]

Pp [kW]

4-POLE
(50 Hz)

46SV SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 4-POLE
AT

DIMENSIONI E PESI SERIE 46SV 4 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

46SV2..4..
46SV3..4..
46SV4..4..
46SV5..4..
46SV6..4..
46SV7..4..
46SV8..4..
46SV9..4..
46SV10..4..
46SV11..4..
46SV12..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

1,1
1,5
2,2
2,2
3
3
4
4
5,5
5,5
5,5

90
90
100
100
100
100
112
112
132
132
132

604
679
754
829
904
979
1054
1129
1224
1299
1374

298
298
322
322
353
353
398
398
405
405
405

174
174
214
214
214
214
214
214
256
256
256

164
164
164
164
164
164
164
164
300
300
300

134
134
168
168
168
168
168
168
191
191
191

16
16
16
16
16
16
16
16
16
16
16

61
65
69
73
77
80
84
88
97
105
109

79
88
98
102
109
112
138
142
156
164
168

46sv-4p50-en_b_td

176

46SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1450 [rpm]

46SV
0
0

20

40

20

ISO 9906:2012 - Grade 3B

60

40

60

100 Q [Imp gpm]

80
80

120 Q [US gpm]


140

100

12

75
70

11

65

10

250

H [ft]

H [m]

80

200

60
9

55

50
45

150

40

4-POLE
(50 Hz)

6
35
5

30

100

25
20

3
50

15
2
10

0
90

70

kW/stage

0,3
2

50

1
0

0
0
0

8
100

12

16

200

20
300

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

177

24
400

28

Q [m /h]
32
Q [l/min]
500

NPSH [ft]

0,4

[%]

0
0,5

05132_D_CH

NPSH [m]

Pp [kW]

4-POLE
(50 Hz)

66SV SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 4-POLE
AT

DIMENSIONI E PESI SERIE 66SV 4 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

66SV1..4..
66SV2..4..
66SV3..4..
66SV4..4..
66SV5..4..
66SV6..4..
66SV7..4..
66SV8..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

1,1
1,5
2,2
3
4
4
5,5
5,5

90
90
100
100
112
112
132
132

554
644
734
824
914
1004
1114
1204

298
298
322
353
398
398
405
405

174
174
214
214
214
214
256
256

164
164
164
164
164
164
300
300

134
134
168
168
168
168
191
191

16
16
16
16
16
16
16
16

66
72
77
82
87
93
103
108

84
95
106
114
141
147
166
171

66sv-4p50-en_b_td

178

66SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1450 [rpm]

66SV
0

50

ISO 9906:2012 - Grade 3B


150 Q [Imp gpm]

100

50

100

Q [US gpm]
200

150

60
55

180

H [ft]

H [m]

50

160

45
6

140

120

40
35

100

30
25

4-POLE
(50 Hz)

4
80
3

20

60
15

2
40

10
1

20

0
80
70

0,6

60

kW/stage
0,4
4

50
12
8

4
0

0
0
0

8
100

12
200

16

20
300

24
400

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

179

28

32
500

36
600

40

Q44
[m /h]
700 Q [l/min]

NPSH [ft]

NPSH [m]

[%]

0
0,8

05133_D_CH

Pp [kW]

4-POLE
(50 Hz)

92SV SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 4-POLE
AT

DIMENSIONI E PESI SERIE 92SV 4 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

92SV1..4..
92SV2..4..
92SV3..4..
92SV4..4..
92SV5..4..
92SV6..4..
92SV7..4..
92SV8..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

1,1
2,2
3
4
5,5
5,5
7,5
7,5

90
100
100
112
132
132
132
132

554
644
734
824
934
1024
1114
1204

298
322
353
398
405
405
405
405

174
214
214
214
256
256
256
256

164
164
164
164
300
300
300
300

134
168
168
168
191
191
191
191

16
16
16
16
16
16
16
16

66
71
77
82
91
97
102
107

84
100
109
136
154
160
169
174

92sv-4p50-en_b_td

180

92SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1450 [rpm]

92SV
0

50

100

50

ISO 9906:2012 - Grade 3B


150

100

150

200
200

250

Q [Imp gpm]
Q [US gpm]

70

H [m]

8
200

60
7

55

H [ft]

220
65

180

50

160

6
45

140
5

40

30
25

4-POLE
(50 Hz)

120

35

100
80

20
60
2

15

40
10
1

20

0
0,9

0
80

[%]

70
0,8

60

0,7
2

50
6
4

2
0
0
0

10
200

15

20

25

30

35

400

600

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

181

40

45

50
800

55

60

NPSH [ft]

NPSH [m]

kW/stage

0
Q 65
[m3/h]

1000 Q [l/min]

05134_D_CH

Pp [kW]

4-POLE
(50 Hz)

125SV SERIES
DIMENSIONS AND WEIGHTS A
T 50 Hz, 4-POLE
AT

DIMENSIONI E PESI SERIE 125SV 4 poli 50 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

125SV1..4..
125SV2..4..
125SV3/3B..4..
125SV4/4B..4..
125SV5/5A..4..
125SV6..4..
125SV7..4..
125SV8..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

1,1
2,2
2,2
3
4
5,5
7,5
7,5

90
100
100
100
112
132
132
132

673
823
973
1123
1273
1443
1593
1743

298
322
322
353
398
405
405
405

174
214
214
214
214
256
256
256

140
160
160
160
160
300
300
300

134
168
168
168
168
191
191
191

16
16
16
16
16
16
16
16

110
121
133
144
155
172
186
199

128
150
162
176
207
234
253
265

125sv-4p50-en_b_td

182

125SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 50 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1450 [rpm]

125SV
0
0

50
50

100
100

150
150

ISO 9906:2012 - Grade 3B


200

200

250

250

300

300 Q [Imp gpm]


350

Q [US gpm]
H [ft]

H [m]

60

50

8
150
7

40
6

100

30

4-POLE
(50 Hz)

5/5A

4/4B

20

3/3B

50

2
10
1

0,75

70
P2 1
P2 /1A
P2 /1B

kW/stage

0,50
3
2

50
30

1
0
0
0

10
200

20

30
400

40
600

50
800

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

183

60
1000

70
1200

80

0
3
Q [m90/h]
Q [l/min]
1400

NPSH [ft]

1,00

[%]

0
90

06066_B_CH

NPSH [m]

Pp [kW]

0
1,25

e-SV SERIES
HYDRA
ULIC PERFORMANCE RANGE A
T 60 Hz, 4-POLE
HYDRAULIC
AT
1750 [rpm]

e-SV

ISO 9906:2012 - Grade 3B

10

Q [Imp gpm]

100

10

Q [US gpm]

100

400

120

H [ft]

H [m]

130

110
350
100
300

90
80

250

4-POLE
(60 Hz)

70
200

60
50

150
40
100
125SV

92SV

66SV

46SV

33SV

22SV

15SV

10SV

5SV

20

3SV

1SV

30

50
10
0
100

5SV
3SV

60

10SV

15SV 22SV

33SV

46SV 66SV 92SV


125SV

1SV

40
20

1
10

10
100

184

Q [m /h]
Q [l/min]

100
1000

06095_C_CH

[%]

80

1, 3, 5SV SERIES
TABELLA DI PRESTAZIONI IDRAULICHE SERIE 1SV 3SV 5SV 4p 60 Hz
HYDRA
ULIC PERFORMANCE T
ABLE A
T 60 Hz, 4-POLE
HYDRAULIC
TABLE
AT
RATED

TYPE

POWER

Q = DELIVERY
l/min 0
3

m /h 0
kW

HP

1SV03..4
1SV05..4
1SV07..4
1SV09..4
1SV11..4
1SV13..4
1SV15..4
1SV17..4
1SV18..4
1SV20..4
1SV22..4
1SV24..4
1SV26..4
1SV28..4
3SV02..4
3SV04..4
3SV06..4
3SV08..4
3SV10..4
3SV12..4
3SV14..4
3SV15..4
3SV17..4
3SV19..4
3SV21..4
3SV23..4
5SV03..4
5SV05..4
5SV07..4
5SV09..4
5SV11..4
5SV13..4
5SV15..4
5SV17..4
5SV19..4
5SV21..4

0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,37
0,37
0,25
0,25
0,25
0,25
0,25
0,25
0,37
0,37
0,37
0,37
0,55
0,55
0,25
0,25
0,25
0,37
0,37
0,55
0,55
0,55
0,75
0,75

0,34
0,34
0,34
0,34
0,34
0,34
0,34
0,34
0,34
0,34
0,34
0,34
0,5
0,5
0,34
0,34
0,34
0,34
0,34
0,34
0,5
0,5
0,5
0,5
0,75
0,75
0,34
0,34
0,34
0,5
0,5
0,75
0,75
0,75
1
1

5SV23..4

0,75

6,7

10

11,7

15

18

23,33

25

30

35

43,3

50

60

83,33

0,4

0,6

0,7

0,9

1,1

1,4

1,5

1,8

2,1

2,6

3,0

3,6

5,0

2,9
5,6
8,1
10,3
12,4
14,4
17,3
18,6
20,4
22,1
23,7
28,7
7,3
11,8
16,3
20,5
25,3
29,0
34,6
38,8
42,9
48,6
52,8

6,9
11,2
15,4
19,3
23,8
27,2
32,6
36,5
40,3
45,8
49,7

6,3
10,1
13,8
17,1
21,2
24,0
29,0
32,4
35,6
40,7
44,1

4,1
6,5
8,5
10,3
12,9
14,1
17,6
19,4
21,1
24,8
26,6

H = TOTAL HEAD IN METRES OF COLUMN OF WATER

6,6
11,0
15,3
19,6
23,9
28,2
32,4
36,6
38,7
42,9
47,0
51,1
55,2
60,0
5,5
10,9
16,3
21,6
26,8
32,0
37,6
40,4
45,5
50,7
55,8
61,9
8,3
13,7
18,8
24,0
29,5
34,7
40,4
45,6
50,8
56,7
61,9

6,7
11,1
15,5
19,8
24,1
28,3
32,5
36,7
38,7
42,8
46,8
50,8
54,7
59,8

6,6
10,9
15,2
19,4
23,5
27,6
31,6
35,6
37,6
41,5
45,3
49,1
52,8
58,0

6,4
10,7
14,8
18,9
23,0
26,9
30,9
34,7
36,6
40,4
44,1
47,7
51,3
56,5
5,5
11,0
16,3
21,4
26,5
31,5
37,1
39,9
44,9
49,8
54,6
61,3

6,1
10,0
13,9
17,7
21,4
25,1
28,6
32,2
33,9
37,4
40,7
44,0
47,3
52,2
5,5
10,8
16,1
21,1
26,0
30,9
36,4
39,2
44,1
48,8
53,5
60,2

5,5
9,1
12,6
16,0
19,3
22,6
25,8
28,9
30,4
33,5
36,4
39,2
42,1
46,7
5,4
10,6
15,8
20,6
25,4
30,1
35,6
38,3
43,0
47,6
52,1
58,9

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A)

185

4,1
6,6
9,2
11,6
13,9
16,1
18,3
20,4
21,4
23,3
25,3
27,0
28,7
32,5
5,1
10,1
14,9
19,5
24,0
28,3
33,5
36,1
40,5
44,7
48,8
55,6

5,0
9,9
14,6
19,0
23,4
27,6
32,7
35,2
39,4
43,5
47,5
54,2
7,9
13,0
18,0
22,8
28,1
32,7
38,6
43,4
48,1
54,1
59,0

4,6
9,1
13,3
17,3
21,3
25,0
29,7
32,0
35,7
39,3
42,8
49,3
7,8
12,7
17,7
22,3
27,5
31,9
37,7
42,4
47,0
52,9
57,6

4,1
8,0
11,7
15,2
18,5
21,7
25,8
27,9
31,0
33,9
36,8
42,9
7,6
12,4
17,2
21,7
26,7
30,9
36,7
41,2
45,6
51,5
56,0

1-5sv-4p60-en_b_th

4-POLE
(60 Hz)

PUMP

10, 15, 22SV SERIES


TABELLA DI PRESTAZIONI IDRAULICHE SERIE 10SV 15SV 22SV 4p 60 Hz
HYDRA
ULIC PERFORMANCE T
ABLE A
T 60 Hz, 4-POLE
HYDRAULIC
TABLE
AT
PUMP

RATED

TYPE

POWER

kW

50

60

70

83,33

95

108,3

141,6

160

175

241,6

250

265

283,3

m3/h 0

3,0

3,6

4,2

5,0

5,7

6,5

8,5

9,6

10,5

14,5

15,0

15,9

17,0

4,8

H = TOTAL HEAD IN METRES OF COLUMN OF WATER

HP

10SV03..4

0,55 0,75

13,0

12,1

11,8

11,4

10,7

10,1

9,1

10SV05..4

0,55 0,75

21,6

20,0

19,4

18,8

17,7

16,6

15,0

9,4

10SV07..4

0,75

29,9

27,2

26,4

25,5

23,9

22,2

19,9

12,1

10SV09..4

0,75

38,5

35,4

34,4

33,2

31,2

29,1

26,3

16,4

10SV11..4

1,1

1,5

47,8

44,9

43,8

42,5

40,3

37,9

34,5

22,8

1,5

56,2

52,8

51,5

49,8

47,1

44,1

40,0

26,0

65,1

61,5

60,0

58,1

55,0

51,6

46,9

30,8

14,3

14,1

13,7

12,7

11,9

11,2

10SV13..4
10SV15..4

4-POLE
(60 Hz)

Q = DELIVERY
l/min 0

1,1
1,5

5,9

15SV03..4

0,55 0,75

15,4

15SV04..4

0,75

20,6

19,2

18,9

18,4

17,0

16,0

15,1

9,0

15SV05..4

1,1

1,5

26,2

24,7

24,4

23,9

22,3

21,1

20,0

12,7

15SV06..4

1,1

1,5

31,3

29,5

29,1

28,5

26,5

25,1

23,7

14,9

15SV07..4

1,5

36,7

34,7

34,2

33,5

31,3

29,7

28,1

17,8

15SV08..4

1,5

42,4

39,6

39,1

38,4

36,0

34,3

32,6

21,5

15SV09..4

2,2

48,0

45,2

44,6

43,8

41,3

39,4

37,5

25,1

15SV10..4

2,2

53,3

50,0

49,4

48,5

45,7

43,6

41,5

27,7

15SV11..4

2,2

58,5

54,9

54,2

53,2

50,1

47,7

45,4

30,2

15SV12..4

2,2

63,8

59,7

58,9

57,9

54,4

51,8

49,3

32,6

22SV02..4

0,55 0,75

11,0

10,1

9,7

9,3

9,0

6,9

6,5

5,8

22SV03..4

0,75

16,5

15,1

14,4

13,9

13,4

10,2

9,6

8,5

7,0

22SV04..4

1,1

1,5

22,2

21,1

20,3

19,7

19,0

14,8

14,0

12,6

10,6

22SV05..4

1,5

27,7

26,2

25,1

24,3

23,5

18,1

17,2

15,4

12,9

22SV06..4

1,5

33,3

31,7

30,4

29,5

28,5

22,1

21,0

18,9

15,9

22SV07..4

2,2

39,1

37,4

36,0

34,9

33,8

26,5

25,2

22,7

19,3

22SV08..4

2,2

44,6

42,6

40,9

39,7

38,4

30,0

28,6

25,7

21,8

22SV09..4

2,2

50,1

47,7

45,9

44,4

43,0

33,5

31,9

28,6

24,2

22SV10..4

55,6

52,8

50,7

49,1

47,6

36,9

35,1

31,5

26,6

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A)

186

6,7

10-22sv-4p60-en_b_th

33, 46, 66, 92, 125SV SERIES


TABELLA DI PRESTAZIONI IDRAULICHE SERIE 33-92SV 4 poli 60 Hz
HYDRA
ULIC PERFORMANCE T
ABLE A
T 60 Hz, 4-POLE
HYDRAULIC
TABLE
AT
PUMP

RATED

TYPE

POWER

Q = CAPACITY
l/min 0

150

200

225

300

350

400

450

500

600

700

800

900

1000

1100

1200

m3/h 0

12

13,5

18

21

24

27

30

36

42

48

54

60

66

72

H = TOTAL HEAD IN METRES OF COLUMN OF WATER

kW

HP

33SV2..4

1,1

1,5

33SV3..4

1,5

33SV4..4

2,2

34 32,2

31,2

33SV5..4

42,7 40,6

39,4

33SV6..4

51,5 49,1

33SV7..4

5,5

33SV8..4

5,5

7,5

33SV9..4

5,5

7,5

77,5 74,1

33SV10..4

5,5

7,5

85,9 82,1

33SV11..4

7,5

10

94,9 90,8

88

87

80

73

63,5

33SV12..4

7,5

10

103,3 98,8

96

94

87

79

68,7

111,8 106,8 104

74

17

16

25,7 24,5

15,5

15,2

13,8

12,5

10,7

23,8

23,3

21,4

19,4

16,9

30,6

27,9

25,3

21,8

38,6

35,3

32

27,7

47,7

46,8

42,9

39

33,9

59,9

57

55

54

49,5

45

38,9

69

66

64

63

58

53

46,2

72

71

65

59

51,5

80

78

72

65

56,7

7,5

10

102

93

85

1,5

19

17,3

16,5

16

15

13,9

12,6

8,9

46SV3..4

2,2

28,8

26,5

25,4

24,4

23,1

21,5

19,5

14,4

46SV4..4

37,9

34,6

33,1

31,6

29,8

27,6

24,8

17,7

46SV5..4

5,5

47,6

43,6

41,7

40

37,7

35

31,6

22,7

46SV6..4

5,5

7,5

57,7

53,1

51

48,9

46,3

43,1

39,1

28,6

46SV7..4

5,5

7,5

67,1

61,7

59

57

54

49,8

45

32,7

46SV8..4

7,5

10

77

70,9

68

65

62

58

52

38,2

46SV9..4

7,5

10

86,4

79,4

76,1

73

69

64

58

42,4

46SV10..4

7,5

10

95,7

87,9

84

81

76

71

64

46,5

46SV11..4

11

15

105,7

97,1

93

89

85

79

71

52

46SV12..4

11

15

115,3

105,9 102

97

92

86

78

57

46SV13..4

11

15

124,9

114,8 110

106

100

93

84

61

66SV1..4

1,5

10,8

9,7

9,5

9,2

8,9

8,6

7,9

7,2

6,1

4,7

66SV2..4

21,1

19,4

19

18,5

17,9

17,4

16,0

14,5

12,5

10,1

66SV3..4

5,5

31,4

29,2

28,5

27,8

27

26,2

24,2

21,7

18,9

15,4

66SV4..4

5,5

7,5

42

39,4

38,7

37,8

36,9

35,8

33,2

30

26,1

21,3

66SV5..4

7,5

10

52,5

49,4

48,5

47,5

46,3

44,9

41,7

37,8

32,8

26,5

66SV6..4

7,5

10

62,7

59

58

57

55

53

49,6

44,8

38,7

31,1

66SV7..4

11

15

73,2

68,8

67

66

64

62

58

52

45,2

36,3

66SV8..4

11

15

83,7

78,6

77

75

73

71

66

60

52

41,5

92SV1..4

1,5

11,8

9,8

9,5

8,9

8,3

7,7

7,1

6,4

5,5

4,1

92SV2..4

23,4

20

19,4

18,3

17,1

16

14,8

13,4

11,7

9,4

92SV3..4

5,5

7,5

35,4

31

30,2

28,5

26,8

25,2

23,4

21,5

19

15,9

92SV4..4

7,5

10

47,2

41,4

40,3

38

35,8

33,6

31,2

28,6

25,4

21,3

92SV5..4

7,5

10

58,5

51,2

50

46,9

44,1

41,4

38,4

35,1

31,1

25,8

92SV6..4

11

15

70,2

61,4

60

56

53

50

46,1

42,1

37,3

30,9

92SV7..4

11

15

81,9

71,6

70

66

62

58

54

49

43,5

36,1

75 Hz71
60

66

62

56

50

41,2

92SV8..4
TABELLA

20
93,6
DI15PRESTAZIONI

IDRAULICHE SERIE

81,8 4p
80
125SV

4-POLE
(60 Hz)

33SV13..4
46SV2..4

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A)

PUMP

RATED

TYPE

POWER

125SV1..4
125SV2/2A..4
125SV3/3B..4
125SV4/4A..4
125SV5/5A..4
125SV6..4
125SV7..4
125SV8..4

kW

HP

2,2
3
4
5,5
7,5
11
11
15

3
4
5,5
7,5
10
15
15
20,5

33-92sv-4p60-en_b_th

Q = DELIVERY
l/min 0

250

300

375

450

500

650

750

850

1000

1200

1300

1400

1500

m3/h 0

15,0

18,0

22,5

27,0

30,0

39,0

45,0

51,0

60,0

72,0

78,0

84,0

90,0

5,3
10,6
13,9
21,3
26,6
36,1
42,2
48,2

4,7
9,6
12,2
19,2
24,0
33,2
38,7
44,2

4,0
8,4
10,3
16,8
21,0
29,8
34,8
39,8

3,2
7,0
8,0
14,1
17,6
26,1
30,4
34,8

H = TOTAL HEAD IN METRES OF COLUMN OF WATER

10,0
18,3
25,5
36,5
45,6
58,7
68,5
78,3

7,9
15,4
21,3
30,9
38,6
50,1
58,4
66,8

Hydraulic performances in compliance with ISO 9906:2012 - Grade 3B (ex ISO 9906:1999 - Annex A)

187

7,4
14,6
20,1
29,3
36,6
47,7
55,6
63,6

7,1
14,1
19,3
28,1
35,2
46,0
53,7
61,3

6,8
13,5
18,3
26,9
33,6
44,2
51,5
58,9

6,2
12,4
16,7
24,8
31,0
41,1
48,0
54,8

125sv-4p60-en_c_th

4-POLE
(60 Hz)

1SV SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT
Hz,, 4-POLE

DIMENSIONI E PESI SERIE 1SV 4 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

1SV03..4
1SV05..4
1SV07..4
1SV09..4
1SV11..4
1SV13..4
1SV15..4
1SV17..4
1SV18..4
1SV20..4
1SV22..4
1SV24..4
1SV26..4
1SV28..4

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,25
0,37
0,37

71
71
71
71
71
71
71
71
71
71
71
71
71
71

278
318
358
398
438
478
518
558
578
618
658
698
738
778

231
231
231
231
231
231
231
231
231
231
231
231
231
231

140
140
140
140
140
140
140
140
140
140
140
140
140
140

105
105
105
105
105
105
105
105
105
105
105
105
105
105

121
121
121
121
121
121
121
121
121
121
121
121
121
121

8,6
9,4
10,2
11
11,8
12,6
13,4
14,2
14,6
15,4
16,2
17
17,8
18,6

15,4
16,2
17
17,8
18,6
19,4
20,2
21
21,4
22,2
23
23,8
25,8
26,6
1sv-4p60-en_a_td

188

1SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1750 [rpm]

0
H [m]

ISO 9906:2012 - Grade 3B


Q [Imp gpm]

Q [US gpm]

200

28

60

H [ft]

1SV

26
24
50
22
150
20
40

18
17
15

4-POLE
(60 Hz)

100

30

13
11

20

09
07

50

05

10

03

NPSH [m]

0,01

40
kW/stage

0,00
3

20

1
0

0
0,0
0

0,2

0,4
5

0,6

0,8

10

1,0
15

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

189

1,2
20

1,4

Q [m /h]
1,6
25Q [l/min]

NPSH [ft]

Pp [kW]

[%]

0
60

06070_B_CH

0
0,02

4-POLE
(60 Hz)

3SV SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT
Hz,, 4-POLE

DIMENSIONI E PESI SERIE 3SV 4 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

3SV02..4..
3SV04..4..
3SV06..4..
3SV08..4..
3SV10..4..
3SV12..4..
3SV14..4..
3SV15..4..
3SV17..4..
3SV19..4..
3SV21..4..
3SV23..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,25
0,25
0,25
0,25
0,25
0,25
0,37
0,37
0,37
0,37
0,55
0,55

71
71
71
71
71
71
71
71
71
71
80
80

278
298
338
378
418
458
498
518
558
598
648
688

231
231
231
231
231
231
231
231
231
231
263
263

140
140
140
140
140
140
140
140
140
140
155
155

105
105
105
105
105
105
105
105
105
105
120
120

121
121
121
121
121
121
121
121
121
121
129
129

8
8,8
9,7
10,5
11,3
12,1
12,9
13,3
14,1
14,9
15,7
16,5

14,8
15,6
16,5
17,3
18,1
18,9
20,9
21,3
22,1
22,9
22,4
23,2

3sv-4p60-en_b_td

190

3SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1750 [rpm]

H [m]

2
2

ISO 9906:2012 - Grade 3B

10 Q [Imp gpm]

8
8

12 Q [US gpm]

10

23

200

60

H [ft]

3SV

21
19

50

150

17
15

40

14
12

4-POLE
(60 Hz)

100

30
10
08
20
06

50

04

10

Pp [kW]

NPSH [m]

0,02
kW/stage

0,01
2

5
1
0

0
0,0
0

0,5

1,0
10

1,5
20

2,0
30

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

191

2,5
40

Q [m /h]
3,0
Q [l/min]
50

NPSH [ft]

0
70
60
50
40
30

06071_B_CH

0
0,03

[%]

02

4-POLE
(60 Hz)

5SV SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT
Hz,, 4-POLE

DIMENSIONI E PESI SERIE 5SV 4 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

5SV03..4..
5SV05..4..
5SV07..4..
5SV09..4..
5SV11..4..
5SV13..4..
5SV15..4..
5SV17..4..
5SV19..4..
5SV21..4..
5SV23..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,25
0,25
0,25
0,37
0,37
0,55
0,55
0,55
0,75
0,75
0,75

71
71
71
71
71
80
80
80
80
80
80

293
343
393
443
493
553
603
653
703
753
803

231
231
231
231
231
263
263
263
231
231
231

140
140
140
140
140
155
155
155
159
159
159

105
105
105
105
105
120
120
120
120
120
120

121
121
121
121
121
129
129
129
128
128
128

8,9
9,9
10,8
11,8
12,8
14,1
15
15
16,9
17,9
18,8

15,7
16,7
17,6
19,8
20,8
20,8
21,7
22,7
29
30
31

5sv-4p60-en_c_td

192

5SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1750 [rpm]

H [m]

10

ISO 9906:2012 - Grade 3B

12

10

14

16

15

18

Q
25[US gpm]

20

23

60

20 Q [Imp gpm]

200

H [ft]

5SV

21

19

50

150

17
40

15

13
100

11

4-POLE
(60 Hz)

30

09
20

07
50
05

10
03

0
80

Pp [kW]

60

0,03

40
kW/stage

2
5
1
0
0,0
0

0,5

1,0

1,5
20

2,0

2,5

3,0

3,5

40

60

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

193

4,0

4,5

5,0
80

0
3
5,5 Q [m
6,0/h]
Q [l/min]
100

NPSH [ft]

20

06072_B_CH

0,02

NPSH [m]

[%]

0
0,04

4-POLE
(60 Hz)

10SV SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT
Hz,, 4-POLE

DIMENSIONI E PESI SERIE 10SV 4 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

10SV03..4..
10SV05..4..
10SV07..4..
10SV09..4..
10SV11..4..
10SV13..4..
10SV15..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,55
0,55
0,75
0,75
1,1
1,1
1,5

80
80
80
80
90
90
90

389
453
517
581
655
719
783

263
263
231
231
298
298
298

155
155
159
159
174
174
174

120
120
120
120
140
140
140

129
129
128
128
134
134
134

16,1
18
19,9
21,7
24
25,8
27,7

22,8
24,7
32
33,8
41,4
43,2
47,7

10sv-4p60-en_c_td

194

10SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1750 [rpm]

10SV
0

10
2

20
4

30

Q [Imp gpm]

10

Q [US
12 gpm]
H [ft]

H [m]

ISO 9906:2012 - Grade 3B

15
200

60
13
50
11

150

40

30

4-POLE
(60 Hz)

09

100

07

05

20

50
03
10

0
80

Pp [kW]

60

0,08

40

kW/stage

0,06

[%]

0
0,10

5
1
0

0
0
0

2
20

4
40

60

6
80

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

195

100

Q [m /h]
10

8
120

140

Q [l/min]
160

NPSH [ft]

06073_B_CH

NPSH [m]

20

4-POLE
(60 Hz)

15SV SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT
Hz,, 4-POLE

DIMENSIONI E PESI SERIE 15SV 4 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

15SV03..4..
15SV04..4..
15SV05..4..
15SV06..4..
15SV07..4..
15SV08..4..
15SV09..4..
15SV10..4..
15SV11..4..
15SV12..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,55
0,75
1,1
1,1
1,5
1,5
2,2
2,2
2,2
2,2

80
80
90
90
90
90
100
100
100
100

447
495
553
601
649
697
755
803
851
899

263
231
298
298
298
298
322
322
322
322

155
159
174
174
174
174
214
214
214
214

120
120
140
140
140
140
160
160
160
160

129
128
134
134
134
134
168
168
168
168

17,9
19,3
21,1
22,5
23,8
25,2
27,4
28,7
30
31,4

24,6
31,4
38,5
39,9
43,8
45,2
56,2
57,5
58,8
60,2

15sv-4p60-en_c_td

196

15SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1750 [rpm]

15SV
0

10

20

30

20

40
40

50

Q [Imp gpm]

60

Q [US gpm]
H [ft]

H [m]

ISO 9906:2012 - Grade 3B

12
60
11
200
10
50
09
08

40

150

4-POLE
(60 Hz)

07
06

30

100
05
04

20

03

50

10

0
80

Pp [kW]

0,20

60
40

kW/stage

20
5

1
0

0
0
0

4
50

100

10
150

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

197

12
200

14

Q [m /h]
16
250Q [l/min]

NPSH [ft]

0,10
2

06074_B_CH

NPSH [m]

0,15

[%]

0
0,25

4-POLE
(60 Hz)

22SV SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT
Hz,, 4-POLE

DIMENSIONI E PESI SERIE 22SV 4 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

22SV02..4..
22SV03..4..
22SV04..4..
22SV05..4..
22SV06..4..
22SV07..4..
22SV08..4..
22SV09..4..
22SV10..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PUMP

PUMP

0,55
0,75
1,1
1,5
1,5
2,2
2,2
2,2
3

80
80
90
90
90
100
100
100
100

399
447
505
553
601
659
707
755
803

263
231
298
298
298
322
322
322
353

155
159
174
174
174
214
214
214
214

120
120
140
140
140
160
160
160
160

129
128
134
134
134
168
168
168
168

16,9
18,2
19,8
21
22,4
24,6
25,9
27,2
28,6

23,6
30,3
37,2
41
42,4
53,4
54,7
56
60,6

22sv-4p60-en_c_td

198

22SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1750 [rpm]

22SV
0

10

20

30

20

ISO 9906:2012 - Grade 3B


40

40

50

60 Q [Imp gpm]

60

Q [US gpm]
H [ft]

H [m]

60
10
50

09
150

08
40

07

06
100

4-POLE
(60 Hz)

30
05
04
20
03

50

02

0
0,30

0
80

Pp [kW]

0,25

60
40
kW/stage

20

1
0

0
0
0

4
50

6
100

10
150

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

199

12
200

16 Q [m /h]
18

14
250

Q [l/min]
300

NPSH [ft]

0,15
3

06075_B_CH

NPSH [m]

0,20

[%]

10

4-POLE
(60 Hz)

33SV SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT
Hz,, 4-POLE

DIMENSIONI E PESI SERIE 33SV 4 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

33SV2..4..
33SV3..4..
33SV4..4..
33SV5..4..
33SV6..4..
33SV7..4..
33SV8..4..
33SV9..4..
33SV10..4..
33SV11..4..
33SV12..4..
33SV13..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

1,1
1,5
2,2
3
3
4
5,5
5,5
5,5
7,5
7,5
7,5

90
90
100
100
100
112
132
132
132
132
132
132

564
639
714
789
864
939
1034
1109
1184
1259
1334
1409

298
298
322
353
353
398
405
405
405
405
405
405

174
174
214
214
214
214
256
256
256
256
256
256

164
164
164
164
164
164
300
300
300
300
300
300

134
134
168
168
168
168
191
191
191
191
191
191

16
16
16
16
16
16
16
16
16
16
16
16

56
60
64
68
72
75
84
88
92
101
105
109

74
83
93
100
104
129
146
150
154
168
172
176

33sv-4p60-en_b_td

200

33SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1750 [rpm]

33SV
0

20

40

20

ISO 9906:2012 - Grade 3B


80 Q [Imp gpm]

60

40

60

100 Q [US gpm]

80

H [m]

H [ft]

120
12

110

350
11

100

10

300

90
80
09
70

250

08
07

50

06

200

4-POLE
(60 Hz)

60

150
05

40

04

100

30
03
20
02

50

0
80

0,5

[%]

0
0,6

0,4

60

0,3
3

1
0
0
0

4
50

6
100

10
150

12

14

200

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

201

16
250

18
300

20

22
350

0
3
Q24[m /h]
Q400
[l/min]

NPSH [ft]

kW/stage

05131B_C_CH

NPSH [m]

Pp [kW]

10

4-POLE
(60 Hz)

46SV SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT
Hz,, 4-POLE

DIMENSIONI E PESI SERIE 46SV 4 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

46SV2..4..
46SV3..4..
46SV4..4..
46SV5..4..
46SV6..4..
46SV7..4..
46SV8..4..
46SV9..4..
46SV10..4..
46SV11..4..
46SV12..4..
46SV13..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

1,5
2,2
3
4
5,5
5,5
7,5
7,5
7,5
11
11
11

90
100
100
112
132
132
132
132
132
160
160
160

604
679
754
829
924
999
1074
1149
1224
1334
1409
1484

298
322
353
398
405
405
405
405
405
494
494
494

174
214
214
214
256
256
256
256
256
313
313
313

164
164
164
164
300
300
300
300
300
350
350
350

134
168
168
168
191
191
191
191
191
240
240
240

16
16
16
16
16
16
16
16
16
16
16
16

61
65
69
73
82
85
89
93
97
109
113
117

84
94
101
127
144
147
156
160
164
235
239
243

46sv-4p60-en b td

202

46SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1750 [rpm]

46SV
0
0

20

40

20

60

40

60

ISO 9906:2012 - Grade 3B

80
80

120 Q [Imp gpm]

100

100

120

140

Q [US
gpm]
160

120

13

110

12

400

H [ft]

H [m]

130

350
11

100

10

90

300

09
80
250

08
70
07

4-POLE
(60 Hz)

200

60
06
50
05

150

40
04
30

100

03

20

02
50

NPSH [m]

kW/stage
0,4
2
1
0
0
0

8
100

12
200

16

20
300

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

203

24
400

28

32
500

[%]

0,6

0
90
80
70
60
50
40

NPSH [ft]

0
0,8

0
3
36 Q [m /h]
Q
[l/min]
600

05132B_C_CH

Pp [kW]

10

4-POLE
(60 Hz)

66SV SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT
Hz,, 4-POLE

DIMENSIONI E PESI SERIE 66SV 4 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

66SV1..4..
66SV2..4..
66SV3..4..
66SV4..4..
66SV5..4..
66SV6..4..
66SV7..4..
66SV8..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

1,5
3
4
5,5
7,5
7,5
11
11

90
100
112
132
132
132
160
160

554
644
734
844
934
1024
1149
1239

298
353
398
405
405
405
494
494

174
214
214
256
256
256
313
313

164
164
164
300
300
300
350
350

134
168
168
191
191
191
240
240

16
16
16
16
16
16
16
16

66
72
77
87
92
98
107
112

89
104
131
149
159
165
233
238

66sv-4p60-en_b_td

204

66SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1750 [rpm]

66SV
0

50

ISO 9906:2012 - Grade 3B

100

50

Q [Imp
200gpm]

150

100

150

200

Q [US gpm]

85
08
250

75

H [ft]

H [m]

80

07
70
65
06

60

200

55
05

50

150

45

4-POLE
(60 Hz)

04

40
35

03

30

100

25
02

20

50

15
01

10

0
80

1,2

70

kW/stage

0,8
6

60
50
15
10
5
0

4
2
0
0

100

10

15
200

20
300

25

30

400

500

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

205

35
600

40

3
/h]
50 Q [m 55

45
700

800

Q900
[l/min]

NPSH [ft]

1,0

[%]

0
1,4

05133B_C_CH

NPSH [m]

Pp [kW]

4-POLE
(60 Hz)

92SV SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT
Hz,, 4-POLE

DIMENSIONI E PESI SERIE 92SV 4 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

92SV1..4..
92SV2..4..
92SV3..4..
92SV4..4..
92SV5..4..
92SV6..4..
92SV7..4..
92SV8..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

1,5
3
5,5
7,5
7,5
11
11
15

90
100
132
132
132
160
160
160

554
644
754
844
934
1059
1149
1239

298
353
405
405
405
494
494
494

174
214
256
256
256
313
313
313

164
164
300
300
300
350
350
350

134
168
191
191
191
240
240
240

16
16
16
16
16
16
16
16

66
71
82
87
92
101
106
111

89
103
144
154
159
227
232
240

92sv-4p60-en_b_td

206

92SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1750 [rpm]

92SV
0

50
50

150

100

90

08

80

07

150

200
200

250

250

Q [Imp gpm]

300

Q [US gpm]
300
H [ft]

H [m]

100

ISO 9906:2012 - Grade 3B

250
70

06
200

60
05
50

4-POLE
(60 Hz)

150

04
40
03

100

30
02

20

50
01

0
1,6

0
80
[%]

70

1,4

60

1,2
4

50
12
8

4
0
0
0

10
200

15

20

25
400

30

35

40

600

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

207

45

50
800

55

60
1000

65

0
[m3/h]
70 Q75
Q
[l/min]
1200

NPSH [ft]

NPSH [m]

kW/stage

05134B_C_CH

Pp [kW]

10

4-POLE
(60 Hz)

125SV SERIES
DIMENSIONS AND WEIGHTS A
T 60 Hz
AT
Hz,, 4-POLE

DIMENSIONI E PESI SERIE 125SV 4 poli 60 Hz


MOTOR

PUMP

DIMENSIONS (mm)

WEIGHT kg

TYPE

125SV1..4..
125SV2/2A..4..
125SV3/3B..4..
125SV4/4A..4..
125SV5/5A..4..
125SV6..4..
125SV7..4..
125SV8..4..

ELECTRIC
kW

SIZE

L1

L2

D1

D2

PN

PUMP

PUMP

2,2
3
4
5,5
7,5
11
11
15

100
100
112
132
132
160
160
160

673
823
973
1143
1293
1478
1628
1778

322
353
398
405
405
494
494
494

214
214
214
256
256
313
313
313

160
160
160
300
300
350
350
350

168
168
168
191
191
240
240
240

16
16
16
16
16
16
16
16

110
121
133
149
160
176
190
203

139
153
184
212
227
301
315
331

125sv-4p60-en_b_td

208

125SV SERIES
OPERA
TING CHARACTERISTIC
S A
T 60 Hz, 4-POLE
OPERATING
CHARACTERISTICS
AT
1750 [rpm]

125SV
0

100

ISO 9906:2012 - Grade 3B

200

100

Q [Imp gpm]

300

200

400 Q [US gpm]

300

H [m]

80
250
H [ft]

7
200

60
6

150
5/5A

4-POLE
(60 Hz)

40
4/4A
100
3/3B
20
2/2A

50

kW/stage
1,0
3
2

60
40

1
0
0
0

10
200

20

30
400

40
600

50
800

These performances are valid for liquids with density = 1.0 Kg/dm3 and kinematic viscosity = 1 mm2/sec.

209

60
1000

70
1200

80
1400

90

0
3
Q [m
/h]
100

Q [l/min]
1600

NPSH [ft]

P2 1
P2 /1A
P2 /1B

1,5

[%]

0
80

06076_D_CH

NPSH [m]

Pp [kW]

0
2,0

210

4-POLE
(60 Hz)

REDUCING
FOOTPRINT

REDUCING
FOOTPRINT
(50/60 Hz)

211

ErP 2009/125/EC (50 Hz)


e-SV SERIES - REDUCING FOOTPRINT
50/60 Hz
Background and context
In industry or in the building services market, reducing
footprint of pumping equipment is one of the main goals
of architects and manufacturing layout designers. They
look for compact solutions which help to save space on
installation, such as compact water supply installation,
compact water booster sets and closed loop circuits.
Therefore Lowara has developed e-SV TM Reducing
Footprint: a pump or booster set which delivers a compact
and original solution to the most critical footprint size.

Benefits of e-SVTM Reducing F


ootprint
Footprint

REDUCING
FOOTPRINT

Compact design
design: e-SVTM Reducing the Footprint offers
up to 50% saving in the plant room dedicated usually for
a traditional vertical multistage pump with suction and
discharge ports designed inline.

Versatile design
design: e-SVTM Reducing Footprint offers
many different configurations with the delivery port above Special features / product benefits
the suction port with 4 adjustable positions. This specific - Specific superposed design of the inlet and outlet allowing
design of the pump allows installing e-SVTM Reducing savings in up to 50% space.
Footprint everywhere, even at a close proximity to a wall. - Standard mechanical seal (EN12756) fitted on all
models. Easy to replace without removing
High level performances
performances: e-SVTM Reducing Footprint the motor from 5,5 kW up.
keeps the same level of performances of the e-SVTM range - Hard material intermediate bush bearing
from size 1SV to 22SV. e-SVTM Reducing Footprint is (Tungsten Carbide) to improve life and ability to withstand
available with round flanges up to PN25.
heavy duty application on all sizes.
- Balanced impeller design to reduce axial thrust
Code identification
for longer standard motor bearing life.
- Wide range of size to cover all requested duty points:
e-SVTM Reducing Footprint design is identified with a
from 1SV to 22SV.
R in the product codification of the whole e-SVTM
R
- IE2 or IE3 standard motors
motors, 3-phase, 2-poles from
range.
0,75 kW to 55 kW with blocked bearing to support
maximum thrust without limiting inlet
R015T
Example: 3SV13R
pressure
pressure..
R = Reducing Footprint.
- i-ALERTTM device to reduce life cycle costs by increasing
Mean time between Failures (MTBF).

Special configurations
e-SV TM Reducing Footprint offers the same range of
configuration of the standard e-SVTM series.
- Materials used: see the Materials section.
- Options for mechanical seals and gaskets:
see the mechanical seals and gaskets section.
- Options for motors and configuration:
see the motors section.
- HYDROVARTM system included: see the e-SVH section
(e-SVTM with HYDROVARTM).

212

e-SV
SERIES - REDUCING FOOTPRINT
TABELLA DI PRESTAZIONI IDRAULICHE SERIE INGOMBRO RIDOTTO 1-22SV 2p 50 H
HYDRA
ULIC PERFORMANCE T
ABLE A
T 50 Hz, 2 POLES
HYDRAULIC
TABLE
AT
PUMP

RATED

TYPE

POWER

MEI

PUMP

RATED

TYPE

POWER

MEI

Q = DELIVERY
H = HEAD
Pp = POWER

kW

HP

0,5
0,75
0,75
0,75
0,75
1
1
1
1,5
1,5
1,5
2
2
2
3
3
3

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

10SV05
10SV06
10SV07
10SV08
10SV09
10SV10
10SV11
10SV13
10SV15
10SV17
10SV18
10SV20
10SV21

2,2
2,2
3
3
4
4
4
5,5
5,5
7,5
7,5
7,5
11

3
3
4
4
5,5
5,5
5,5
7,5
7,5
10
10
10
15

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

np = EFFICIENCY

3SV07
3SV08
3SV09
3SV10
3SV11
3SV12
3SV13
3SV14
3SV16
3SV19
3SV21
3SV23
3SV25
3SV27
3SV29
3SV31
3SV33

0,75
0,75
1,1
1,1
1,1
1,1
1,5
1,5
1,5
2,2
2,2
2,2
2,2
3
3
3
3

1
1
1,5
1,5
1,5
1,5
2
2
2
3
3
3
3
4
4
4
4

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

15SV04
15SV05
15SV06
15SV07
15SV08
15SV09
15SV10
15SV11
15SV13
15SV15
15SV17

4
4
5,5
5,5
7,5
7,5
11
11
11
15
15

5,5
5,5
7,5
7,5
10
10
15
15
15
20
20

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

5SV07
5SV08
5SV09
5SV10
5SV11
5SV12
5SV13
5SV14
5SV15
5SV16
5SV18
5SV21
5SV23
5SV25
5SV28
5SV30
5SV33

1,1
1,1
1,5
1,5
1,5
2,2
2,2
2,2
2,2
2,2
3
3
4
4
4
5,5
5,5

1,5
1,5
2
2
2
3
3
3
3
3
4
4
5,5
5,5
5,5
7,5
7,5

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

22SV04
22SV05
22SV06
22SV07
22SV08
22SV09
22SV10
22SV12
22SV14
22SV17

4
5,5
7,5
7,5
11
11
11
15
15
18,5

5,5
7,5
10
10
15
15
15
20
20
25

0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70
0,70

1-22sv-RErP-2p50-en a th

213

REDUCING
FOOTPRINT

HP

0,37
0,55
0,55
0,55
0,55
0,75
0,75
0,75
1,1
1,1
1,1
1,5
1,5
1,5
2,2
2,2
2,2

For hydraulic performance values, consult the standard e-SVTM catalogue

kW

1SV07
1SV08
1SV09
1SV10
1SV11
1SV12
1SV13
1SV15
1SV17
1SV19
1SV22
1SV25
1SV27
1SV30
1SV32
1SV34
1SV37

214

REDUCING
FOOTPRINT

HORIZON
TAL
HORIZONT
INST
ALLA
TION
INSTALLA
ALLAT

HORIZONTAL
INSTALLATION
(50/60 Hz)

215

ErP 2009/125/EC (50 Hz)


e-SV SERIES - HORIZONT
AL INST
ALLA
TION
HORIZONTAL
INSTALLA
ALLATION
50/60 Hz
Background and context
In some applications where room is reduced vertically, it is
mandatory to have some pumps systems able to deliver
high pressure performances together with a limited
occupied vertical space. Therefore Lowara proposes the
full range of e-SVTM in the horizontal position: a pump
which delivers from a vertical space saving solution
together with the high performance of the e-SVTM series.

Benefits of e-SVTM Horizontal

Reduced use of the vertical space


space: e-SV TM
Horizontal reduces the space usually used vertically by the
traditional vertical multistage pumps thanks to a specific
range of accessories which allows the installation of the
pump in a horizontal position.
Easy installation
installation: any e-SVTM pumps can be installed
in a horizontal position. Lowara has developed some
specific accessories, which according to the pump model
and motor, allow any e-SVTM multi-stage vertical pump to
be installed horizontally.

Code identification

HORIZON
TAL
HORIZONT
TION
ALLA
INST
ALLAT
INSTALLA

There is no specific code identification for e-SV TM


Horizontal, since its a different installation of the standard
e-SVTM series.

Special features / product benefits

Operating characteristics

By being a different installation of the e-SVTM series, the For hydraulic performance values, consult the standard
special features and products benefits of e-SVTM Horizontal e-SVTM catalogue.
are the same as the standard e-SVTM series.

Special configurations
e-SVTM Horizontal offers the same range of configuration
of the standard e-SVTM series:
- Materials used: see the Materials section.
- Options for mechanical seals and gaskets:
see the mechanical seals and gaskets section.
- Options for motors and configuration:
see the motors section.
- HYDROVARTM system included: see the e-SVH section
(e-SVTM with HYDROVARTM).

NOTE (50 Hz)


For information relative to the MEI index, hydraulic
performance (Q, H, Pp, np) and anything other points
concerning Regulation (EU) n. 547/2012, consult the
standard e-SVTM catalogue.

216

1-22SV - HORIZONT
AL INST
ALLA
TION
HORIZONTAL
INSTALLA
ALLATION

(For dimensions L1, L2, M, D1, consult the standard e-SVTM catalogue).

1, 3, 5SV (F
-N VERSIONS)
(F-N

DIMENSIONI SERIE 1-3-5 SV ORIZZ


DIMENSIONS
(mm)
H

MOTOR
kW

SIZE

0,370,55
0,751,1
1,52,2
34
5,5

71
108
80
118
90
128
100-112
138
132
158
DIMENSIONI

SERIE 10-15-

1-5svor-2p50-en_a_td

10, 15, 22SV (F


-N VERSIONS)
(F-N
(0,7511 kW)

DIMENSIONS
(mm)
B

PUMP
TYPE

10SV
15SV
22SV

280
300
10-22svor-b-en_a_td

kW

SIZE

DIMENSIONS
(mm)
H

0,751,1
1,52,2
34
5,57,5
11

80
90
100-112
132
160

142
152
162
228
258

MOTOR

10-22svor-2p50-en_a_td

15, 22SV (F
-N VERSIONS)
(F-N
(1518,5 kW)

217

HORIZON
TAL
HORIZONT
INST
ALLA
TION
INSTALLA
ALLAT

DIMENSIONI SERIE 10-15-22 SV O

33-92SV - HORIZONT
AL INST
ALLA
TION
HORIZONTAL
INSTALLA
ALLATION

(For dimensions L1, L2, M, D1, consult the standard e-SVTM catalogue).

33, 46, 66, 92SV (G-N VERSIONS)


(1,111 kW)

DIMENSIONI SERIE 33-92SV ORIZZONTALE FINO A 11k


DIMENSIONS (mm)

PUMP
TYPE

33SV
46-66-92SV

MOTOR

kW

SIZE

DIMENSIONS (mm)
H

105
140

320
365

1,14
5,57,5
11

90-100-112
132
160

196
216
251
33-92svo-11kw-2p50-en_a_td

HORIZON
TAL
HORIZONT
TION
ALLA
INST
ALLAT
INSTALLA

33, 46, 66, 92SV (G-N VERSIONS)


(1522 kW)

DIMENSIONI SERIE 33-92SV ORI


DIMENSIONS (mm)

PUMP
TYPE

33SV
46-66-92SV

105
140

320
365

33-92svo-22kw-2p50-en_a_td

33, 46, 66, 92SV (G-N VERSIONS)


(3045 kW)

DIMENSIONI SERIE 33-92SV ORIZZONTALE DA 30 A 45kW 2 poli 50 Hz


PUMP
TYPE

33SV
46-66-92SV

DIMENSIONS (mm)

MOTOR

DIMENSIONS (mm)

kW

SIZE

E1

F1

105
140

320
365

3037
45

200
225

133
149

305
311

370
412

318
356

385
436

82
80

33-92svo-45kw-2p50-en_b_td

218

125SV - HORIZONT
AL INST
ALLA
TION
HORIZONTAL
INSTALLA
ALLATION

(For dimensions L1, L2, M, D1, consult the standard e-SV TM catalogue).

125SV (G-N VERSIONS)


(7,5 kW)

HORIZON
TAL
HORIZONT
INST
ALLA
TION
INSTALLA
ALLAT

125SV (G-N VERSIONS)


(1545 kW)

DIMENSIONI SERIE 125SV ORIZZONTALE DA 15 A 45kW 2 poli 50 H


MOTOR
kW
15
22
3037
45

SIZE
160
180
200
225

H
108
108
133
149

E
254
254
305
311

DIMENSIONS
( mm )
E1
F
304
390
304
390
370
465
412
515

F1
430
430
505
565

G
53
53
53
58

125svor-15-45kw-2p50-en_a_td

125SV (G-N VERSIONS)


(55 kW)

219

220

HORIZON
TAL
HORIZONT
TION
ALLA
INST
ALLAT
INSTALLA

MOTORS

MOTORS
(50/60 Hz)

221

ErP 2009/125/EC
e-SV SERIES
MOTORS A
T 50 Hz
AT
With the Energy using Products (EuP 2005/32/EC) and Energy related Products (ErP 2009/125/EC) directives,
the European Commission has established requirements for promoting the use of products with low power
consumption.
The various products considered include three-phase, 50 Hz surface motors, with power outputs ranging from 0,75
to 375 kW, also when integrated with other products, with characteristics as defined by the specific Regulation
(EC) n. 640/2009 implementing the requirements of the EuP and ErP Directives which also establish the following
deadlines:
from

kW

minimum level of efficiency (IE)

16th June 2011

0,75 375

IE2

< 7,5
1st January 2015

1st January 2017

7,5 375
0,75 375

IE2
IE3
IE2 fitted with variable speed drive
IE3
IE2 fitted with variable speed drive

Standard supplied SV electric pumps are equipped with standard motors.

Standard three-phase surface motors

Single-phase version:
220-240 V 50 Hz
Built-in automatic reset overload protection up
to 1,5 kW.
For higher powers the protection must be provided
by the user.
Three-phase version:
220-240/380-415 V 50 Hz for power up to 3 kW.
380-415/660-690 V 50 Hz for power above 3 kW.
Overload protection to be provided by the user.

Standard options surface motors


In addition to a wide range of motors and special voltages, Lowara offers a wide range of standard options to
cover all applications linked with the installation of the vertical multistage pumps e-SV:
High efficiency
High efficiency IE3 motors
IE2 motors with variable speed drive HYDROVARTM

Installation in harsh environments


Ambient temperature > 40C (max. 60C)
Protected to IP56 or IP65
Anti-condensation heaters
Tropicalisation
Protective canopy
Certification for marine use
Potentially explosive atmosphere (ATEX)

Motor protection (three-phase)


PT100 temperature sensors (linear) in the windings
PTC temperature sensors in the windings
PTO bimetal thermal protectors in the windings
PTC in the bearings (only for larger motors)

Lowara keeps the right to supply motors from other brand to satisfy some of the requests.

MOTORI MONOFASE PER SERIE 1-22 SV 50 Hz, 2 poli

MOTOR TYPE

0,37
0,55
0,75
1,1
1,5
2,2

SM71RB14/104
SM71B14/105
SM80RB14/107
SM80B14/111
SM90RB14/115
PLM90B14/122

71R
71
80R
80
90R
90

V18/B14

PN
kW

Construction
Design

SINGLE-PHASE MOTORS A
T 50 Hz, 2-POLE
AT
IEC SIZE*

MOTORS

50Hz

0,75 kW supplied as IE2 or IE3


IE3.
Short-circuit squirrel-cage motor, enclosed
construction with external ventilation (TEFC).
IP55 protection degree.
Insulation class 155 (F).
Electrical performances according to EN 60034-1.
IE efficiency according to EN 60034-30 ( 0,75 kW).
Cable gland with metric according to EN 50262.
PTC included in motors from 30 to 55 kW.

INPUT

CAPACITOR

DATA FOR 230 V 50 Hz VOLTAGE

CURRENT
In (A)

Tn

220-240 V

2,79-2,85
3,76-3,99
4,90-4,85
6,88-6,65
9,21-8,58
12,5-11,6

14
16
20
30
40
70

450
450
450
450
450
450

* R = Reduced size of motor casing as compared to shaft extension and flange.

min

ls / ln

cos

Nm

Ts/Tn

Tm/Tn

2745
2820
2765
2800
2810
2825

2,64
3,72
3,42
3,89
4,00
4,47

65,1
68,9
70,1
74,7
76,1
82,4

0,96
0,91
0,96
0,96
0,98
0,97

1,39
1,86
2,59
3,75
5,09
7,43

0,68
0,61
0,58
0,46
0,39
0,53

1,63
2,00
1,75
1,72
1,74
1,87

-1

1-22sv-motm-2p50-en_b_te

222

e-SV
MOTORI SERIES
TRIFASE PER SERIE 1-125 SV 50 Hz, 2 poli (fino a 22 kW)
THREE-PHASE MOTORS A
T 50 Hz, 2-POLE (up to 22 kW)
AT
Year of
manufacture

Efficiency N
%
380 V

400 V

Y 380 V

Y 400 V

Y 415 V

Y 660 V

Y 690 V

415 V
IE

kW

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22

82,5
84,0
85,6
83,7
85,5
86,3
87,6
88,6
90,3
90,3
91,2
91,3

83,1
84,7
86,5
83,7
86,8
86,3
87,6
88,1
91,1
90,3
91,2
91,3

81,3
83,4
85,8
83,7
85,6
86,3
87,6
88,1
90,3
90,3
91,2
91,3

82,8
84,4
85,9
83,7
86,1
86,3
87,6
88,6
90,3
90,3
91,2
91,3

82,7
84,5
86,4
83,7
86,8
86,3
87,6
88,1
91,1
90,3
91,2
91,3

80,1
82,5
84,9
83,7
85,6
86,3
87,6
88,1
90,3
90,3
91,2
91,3

82,6
84,3
86,0
83,7
86,3
86,3
87,6
88,6
90,3
90,3
91,2
91,3

82,0
84,0
86,0
83,7
86,8
86,3
87,6
88,1
91,1
90,3
91,2
91,3

78,9
81,4
84,0
83,7
85,6
86,3
87,6
88,1
90,3
90,3
91,2
91,3

82,5
84,0
85,6
83,7
85,5
86,3
87,6
88,6
90,3
90,3
91,2
91,3

82,0
84,0
86,0
83,7
86,8
86,3
87,6
88,1
91,1
90,3
91,2
91,3

78,9
81,4
84,0
83,7
85,6
86,3
87,6
88,1
90,3
90,3
91,2
91,3

82,5
84,0
85,6
83,7
85,5
86,3
87,6
88,6
90,8
90,3
91,2
91,3

82,0
84,0
86,0
83,7
86,8
86,3
87,6
88,1
91,1
90,3
91,2
91,3

78,9
81,4
84,0
83,7
85,6
86,3
87,6
88,1
90,3
90,3
91,2
91,3

82,5
84,0
85,6
83,7
85,5
86,3
87,6
88,6
91,0
90,3
91,2
91,3

82,0
84,0
86,0
83,7
86,8
86,3
87,6
88,1
91,1
90,3
91,2
91,3

78,9
81,4
84,0
83,7
85,6
86,3
87,6
88,1
90,3
90,3
91,2
91,3

71R
71
80
80
90R
90
100R
112R
132R
132
160R
160
160
180R

N. of
Poles

TN

fN
Hz

cos

ls / lN

Nm

Ts/TN

Tm/Tn

50

0,66
0,74
0,78
0,79
0,80
0,80
0,82
0,85
0,87
0,87
0,87
0,91
0,88
0,89

4,32
5,97
7,38
8,31
8,80
8,63
8,39
9,52
10,3
9,21
9,72
8,45
9,75
9,50

1,38
1,85
2,48
3,63
4,96
7,25
9,96
13,1
18,1
24,5
36,0
48,6
59,8
71,1

4,14
3,74
3,57
3,95
4,31
3,74
3,50
3,04
4,43
3,26
3,46
2,26
2,82
2,74

3,13
3,56
3,75
3,95
4,10
3,71
3,32
4,40
5,80
4,55
4,56
3,81
4,53
4,26

Voltage UN

Operating conditions **

PN
kW

0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22

220 V 230 V 240 V 380 V 400 V 415 V 380 V 400 V 415 V 660 V 690 V
IN (A)

2,20
2,56
2,96
4,19
5,56
8,05
10,8
13,6
18,3
25,4
36,0
47,2
58,3
68,3

2,34
2,56
2,94
4,14
5,49
8,04
10,6
13,5
18,0
24,8
35,1
45,3
56,9
66,2

2,51
2,62
2,96
4,16
5,51
8,09
10,6
13,5
17,9
24,4
34,7
44,0
55,9
64,3

1,27
1,48
1,71
2,42
3,21
4,65
6,23
7,88
10,6
14,7
20,8
27,2
33,7
39,4

1,35
1,48
1,70
2,39
3,17
4,64
6,14
7,77
10,4
14,3
20,3
26,2
32,9
38,2

1,45
1,51
1,71
2,40
3,18
4,67
6,12
7,79
10,3
14,1
20,0
25,4
32,3
37,1

1,70
2,41
3,21
4,62
6,18
7,80
10,6
14,5
20,8
27,2
34,1
40,0

1,69
2,38
3,18
4,61
6,10
7,63
10,4
14,0
20,3
26,0
33,2
38,6

1,70
2,38
3,19
4,63
6,06
7,65
10,5
13,9
20,1
25,3
32,8
37,8

0,98
1,39
1,85
2,67
3,57
4,51
6,14
8,35
12,0
15,7
19,7
23,1

0,98
1,37
1,84
2,66
3,52
4,41
6,02
8,11
11,7
15,0
19,1
22,3

nN
min-1

2740 2790
2825 2850
2875 2895
2870 2900
2870 2895
2885 2900
2850 2885
2895 2920
2885 2905
2920 2935
2910 2925
2940 2950
2945 2955
2945 2955

Observe the regulations and codes locally


in force regarding sorted waste disposal.

Altitude

T. amb

Above Sea

min/max

Level (m)

1000

-15 / 40

ATEX

No

sv-ie2-mott22-2p50-en_c_te

* R = Reduced size of motor casing as compared to shaft extension and flange.


** Operating conditions to be referred to motor only. About electric pump, refer to limits in users manual.

223

50Hz

SM71RB14/304
SM71B14/305
SM80B14/307PE
SM80B14/311PE
SM90RB14/315PE
PLM90B14/322
PLM100RB14/330
PLM112RB14/340
PLM132RB5/355
PLM132B5/375
PLM160RB5/3110
PLM160B5/3150
PLM160B5/3185
PLM180RB5/3220

0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22

MOTORS

Model

V18/B14

PN
kW

Data for 400 V / 50 Hz Voltage

V1/B5

Manufacturer

Lowara srl Unipersonale


Reg. No. 03471820260
Montecchio Maggiore Vicenza - Italia

By June 2011

240 V

Construction
Design

230 V

IEC SIZE*

PN

220 V

e-SV
MOTORI SERIES
TRIFASE PER SERIE 1-125 SV 50 Hz, 2 poli (da 30kW fino a 55kW)
THREE-PHASE MOTORS A
T 50 Hz, 2-POLE (from 30 to 55 kW)
AT
Year of
manufacture

Efficiency N
%
400 V

Y 660 V

Y 690 V

415 V
IE

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

30
37
45
55

92,6
93,0
93,2
93,6

92,9
93,3
93,5
93,8

92,7
93,2
93,4
93,8

92,5
93,0
93,3
93,6

93,0
93,4
93,6
93,9

92,9
93,3
93,6
93,9

93,0
93,5
93,8
94,0

93,0
93,4
93,6
93,8

92,3
92,8
93,1
93,3

PN

WEG Equipamentos Eletricos S.A.


Reg. No. 07.175.725/0010-50
Jaragua do Sul - SC (Brazil)

kW

Model

200
200
225
250

N. of
Poles

TN

fN
Hz

cos

ls / lN

Nm

Ts/TN

Tm/Tn

50

0,87
0,87
0,89
0,89

6,50
6,80
7,00

97,00
120,0
145,0
178,0

2,40
2,40
2,20

2,70
2,60
2,80

2,20

2,80

7,00

Voltage UN

Operating conditions **

V
380 V

400 V

55,90
68,70
81,50
99,20

53,60
65,80
78,00
95,00

kW

30
37
45
55

Y
415 V
IN (A)

660 V

690 V

nN

52,20
64,00
75,80
92,50

32,18
39,.55
46,92
57,12

31,07
38,14
45,22
55,07

2950 2960
2945 2955
2955 2960
2955 2960

-1

min

** Operating conditions to be referred to motor only. About electric pump, refer to limits in users manual.

See note.

PN

Data for 400 V / 50 Hz Voltage

V1/B5

W22 200L2-B5 30kW


W22 200L2-B5 37kW
W22 225S/M2-B5 45kW
W22 250S/M2-B5 55kW

30
37
45
55

IEC SIZE

Manufacturer

Construction
Design

kW

By June
2011

PN

380 V

Altitude

T. amb

Above Sea

min/max

Level (m)

1000

-15 / 40

ATEX

No

sv-ie2-mott55-2p50-en_a_te

MOTORS

50Hz

Note: Observe the regulations and codes locally in force regarding sorted waste disposal.

RUMOROSITA' MOTORI SV 2-POLI 50Hz

MOTOR NOISE A
T 50 Hz, 2-POLE
AT
POWER

MOTOR TYPE

The table show the mean sound pressure (Lp) measured


as per Curve A (Standard ISO 1680).
Noise values were measured with the 50 Hz motor
running idle with a tolerance of 3 dB (A).

NOISE
LpA

kW

IEC SIZE*

dB

0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
45
55

71R
71
80-80R
80
90-90R
90
100R
112R
132R
132
160R
160
160
180R
200
200
225
250

<70
<70
<70
<70
<70
<70
<70
<70
<70
71
73
71
73
70
72
72
75
75

*R = Reduced motor casing size with respect


to shaft extension and related flange.

1-125sv_mott_2p50-en_b_tr

224

e-SV
MOTORI SERIES
TRIFASE PER SERIE 1-125 SV 50 Hz, 4 poli (fino a 15 kW)
THREE-PHASE MOTORS A
T 50 Hz, 4-POLE
AT
Year of
manufacture

Efficiency N
%
380 V

400 V

Y 380 V

Y 400 V

Y 415 V

Y 660 V

Y 690 V

415 V
IE

kW

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5

80,4
81,4
83,1
84,7
85,5
86,6
88,0
88,7

81,3
81,4
83,1
84,7
85,5
86,6
88,0
88,7

79,8
81,1
82,0
84,7
84,1
86,6
88,0
88,7

81,1
81,4
83,1
84,7
85,5
86,6
88,0
88,7

81,4
81,4
83,1
84,7
85,5
86,6
88,0
88,7

79,1
81,1
82,0
84,7
84,1
86,6
88,0
88,7

81,4
81,4
83,1
84,7
85,5
86,6
88,0
88,7

81,2
81,4
83,1
84,7
85,5
86,6
88,0
88,7

78,4
81,1
82,0
84,7
84,1
86,6
88,0
88,7

80,4
81,4
83,1
84,7
85,5
86,6
88,0
88,7

81,2
81,4
83,1
84,7
85,5
86,6
88,0
88,7

78,4
81,1
82,0
84,7
84,1
86,6
88,0
88,7

80,4
81,4
83,1
84,7
85,5
86,6
88,0
88,7

81,2
81,4
83,1
84,7
85,5
86,6
88,0
88,7

78,4
81,1
82,0
84,7
84,1
86,6
88,0
88,7

80,4
81,4
83,1
84,7
85,5
86,6
88,0
88,7

81,2
81,4
83,1
84,7
85,5
86,6
88,0
88,7

78,4
81,1
82,0
84,7
84,1
86,6
88,0
88,7

71
71
80
80
90
90
100
100
112
132
132

TN

fN
Hz

50

cos

ls / lN

Nm

Ts/TN

Tm/Tn

0,59
0,60
0,67
0,75
0,72
0,67
0,77
0,73
0,78
0,78
0,78

3,58
3,39
3,95
5,78
6,34
6,79
7,50
7,84
7,91
7,89
7,71

1,71
2,57
3,77
5,03
7,27
9,88
14,4
19,6
26,3
35,9
49,1

3,16
3,40
2,45
2,77
2,80
3,33
2,71
2,96
2,86
2,79
2,75

2,63
2,47
2,38
3,31
3,43
3,67
3,97
4,09
3,94
3,47
3,63

Voltage UN

kW

0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5

220 V 230 V 240 V 380 V 400 V 415 V 380 V 400 V 415 V 660 V 690 V
IN (A)

1,68
2,46
2,98
3,08
4,64
6,50
8,49
12,0
15,5
20,4
27,4

1,71
2,53
3,03
3,03
4,61
6,51
8,31
11,9
15,3
19,9
26,8

1,77
2,62
3,10
3,01
4,61
6,62
8,24
12,0
15,2
19,6
26,4

0,97
1,42
1,72
1,78
2,68
3,75
4,90
6,91
8,93
11,8
15,8

0,99
1,46
1,75
1,75
2,66
3,76
4,80
6,89
8,82
11,5
15,5

1,02
1,51
1,79
1,74
2,66
3,82
4,76
6,94
8,78
11,3
15,2

1,78
2,66
3,74
4,87
6,88
8,80
11,9
15,9

1,75
2,64
3,75
4,78
6,86
8,64
11,5
15,6

1,74
2,64
3,80
4,72
6,90
8,60
11,5
15,4

1,03
1,54
2,16
2,81
3,97
5,08
6,85
9,20

1,01
1,53
2,16
2,76
3,96
4,99
6,66
8,98

** Operating conditions to be referred to motor only. About electric pump, refer to limits in users manual.

225

nN
min-1

1375 1400
1355 1380
1380 1400
1410 1430
1435 1445
1440 1450
1445 1455
1455 1465
1445 1455
1455 1465
1450 1460

Observe the regulations and codes locally


in force regarding sorted waste disposal.

Operating conditions **

V
PN

50Hz

SM471B14/302
SM471B14/304
SM480B14/305
LLM480B14/307
PLM490B14/311
PLM490B14/315
PLM4100B14/322
PLM4100B14/330
PLM4112B14/340
PLM4132B5/355
PLM4132B5/375

0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5

N. of
Poles

Altitude

T. amb

Above Sea

min/max

Level (m)

1000

-15 / 40

ATEX

No

sv-ie2-mott15-4p50-en_b_te

MOTORS

Model

V18/B14

PN
kW

Data for 400 V / 50 Hz Voltage

V1/B5

Manufacturer

Lowara srl Unipersonale


Reg. No. 03471820260
Montecchio Maggiore Vicenza - Italia

By June 2011

240 V

Construction
Design

230 V

IEC SIZE

PN

220 V

e-SV SERIES
MOTOR NOISE A
T 50 Hz, 4-POLE
AT
The table show the mean sound pressure (Lp) measured as per Curve A (Standard ISO 1680).
Noise values were measured with the 50 Hz motor running idle with a tolerance of 3 dB (A).

RUMOROSITA' MOTORI SV 4-POLI 50Hz

MOTORS A
T 50 Hz, 4-POLE
AT
NOISE

POWER

MOTOR TYPE

kW

IEC SIZE

dB

71
71
80
80
90
90
100
100
112
132
132

<70
<70
<70
<70
<70
<70
<70
<70
<70
<70
<70

LpA

0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5

MOTORS

50Hz

1-125sv_mott_4p50-en_a_tr

226

e-SV SERIES
MOTORS A
T 60 Hz
AT
Standard supplied SV electric pumps are equipped with standard motors.

The three-phase motors 0,75 kW supplied

Single-phase version:

standard are IE2 or IE3 according to IEC


60034-30
60034-30.
Short-circuit squirrel-cage motor, enclosed
construction with external ventilation (TEFC).
IP55 protection degree.
Insulation class 155 (F).
Electrical performances according to EN 60034-1.
IE efficiency according to EN 60034-30 ( 0,75 kW).
Cable gland with metric according to EN 50262.
PTC included in motors from 30 to 55 kW.

220-230 V 60 Hz
with built-in automatic reset overload protection up
to 1,5 kW. For higher powers the protection must be
provided by the user.
Three-phase version:
220 V , 380 V , 60 Hz up to 55 kW.
Overload protection to be provided by the user.

Standard options surface motors


In addition to a wide range of motors and special voltages, Lowara offers a wide range of standard options to
cover all applications linked with the installation of the vertical multistage pumps e-SV:
High efficiency
High efficiency IE3 motors
IE2 motors with variable speed drive HYDROVARTM
EISA 2007 - NEMA EFFICIENT (~ IE2)
EISA 2007 - NEMA PREMIUMTM (~ IE3)

Approvals
UL recognized
CSA
Motor protection (three-phase)
PT100 temperature sensors (linear) in the windings
PTC temperature sensors in the windings
PTO bimetal thermal protectors in the windings
PTC in the bearings (only for larger motors)

Installation in harsh environments


Ambient temperature > 40C (max. 60C)
Protected to IP56 or IP65
Anti-condensation heaters
Tropicalisation
Protective canopy
Certification for marine use
Potentially explosive atmosphere (ATEX)

60Hz

Other
Other:
Electrically insulated bearings
Increased service factor (S.F. 1.15)

MOTORS

Lowara keeps the right to supply motors from other brand to satisfy some of the requests.

0,4
0,55
0,75
1,1
1,5
2,2

SM71RB14/1046
SM71B14/1056
SM80RB14/1076
SM80B14/1116
SM90RB14/1156
PLM90B14/1226

71R
71
80R
80
90R
90

Construction
Design

MOTOR TYPE

V18/B14

PN
kW

IEC SIZE*

MOTORI MONOFASE PER SERIE 1-22 SV 60 Hz, 2 poli


SINGLE-PHASE MOTORS A
T 60 Hz, 2-POLE
AT
INPUT

CAPACITOR

DATA FOR 220 V 60 Hz VOLTAGE

CURRENT
In (A)

Tn

220-230 V

2,86-2,94
3,68-3,62
4,98-4,88
6,94-6,89
9,28-9,35
12,3-11,7

14
16
20
30
40
60

450
450
450
450
450
450

* R =Reduced size of motor casing as compared to shaft extension and flange.

min

ls / ln

cos

Nm

Ts/Tn

Tm/Tn

3385
3400
3380
3435
3455
3455

3,80
4,28
3,90
4,54
4,91
4,99

67,5
70,2
69,8
74,2
76,3
83,4

0,94
0,97
0,98
0,97
0,96
0,98

1,13
1,54
2,12
3,06
4,14
6,08

0,73
0,66
0,64
0,62
0,49
0,54

2,04
2,11
1,91
2,03
2,19
2,06

-1

1-22sv-motm-2p60_en_d_te

227

e-SV
MOTORI SERIES
TRIFASE PER SERIE 1-125SV Ie2 60 Hz, 2 poli (fino a 22 kW)
THREE-PHASE MOTORS A
T 60 Hz, 2-POLE (up to 22 kW)
AT
Efficiency N
%
380 V

400 V

Y 380 V

Y 400 V

Y 660 V

Y 690 V

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

0,4
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22

83,4
85,6
87,2
85,5
87,8
87,5
88,5
89,5
90,2
90,2
91,0
91,0

82,4
85,0
87,0
85,5
88,0
87,5
88,5
89,5
90,2
90,2
91,0
91,0

79,0
82,1
84,6
84,5
86,0
86,8
88,5
88,5
89,7
90,2
91,0
91,0

83,4
85,6
87,2
85,5
87,8
87,5
88,5
89,5
90,2
90,2
91,0
91,0

82,4
85,0
87,0
85,5
88,0
87,5
88,5
89,5
90,2
90,2
91,0
91,0

79,0
82,1
84,6
84,5
86,0
86,8
88,5
88,5
89,7
90,2
91,0
91,0

83,4
85,6
87,2
85,5
87,8
87,5
88,5
89,5
90,2
90,2
91,0
91,0

82,4
85,0
87,0
85,5
88,0
87,5
88,5
89,5
90,2
90,2
91,0
91,0

79,0
82,1
84,6
84,5
86,0
86,8
88,5
88,5
89,7
90,2
91,0
91,0

83,4
85,6
87,2
85,5
87,8
87,5
88,5
89,5
90,2
90,2
91,0
91,0

82,4
85,0
87,0
85,5
88,0
87,5
88,5
89,5
90,2
90,2
91,0
91,0

79,0
82,1
84,6
84,5
86,0
86,8
88,5
88,5
89,7
90,2
91,0
91,0

71R
71
80
80
90R
90
100R
112R
132R
132
160R
160
160
180R

fN

TN
ls / lN

Nm

Ts/TN

Tm/Tn

60

0,81
0,84
0,79
0,80
0,82
0,83
0,84
0,87
0,89
0,88
0,88
0,91
0,89
0,91

4,76
5,83
8,25
9,11
9,79
9,59
9,12
10,0
11,4
9,83
10,2
8,60
9,97
9,64

1,16
1,55
2,05
3,01
4,10
6,00
8,22
10,87
14,97
20,29
29,81
40,41
49,72
59,15

3,48
3,09
3,80
4,15
4,36
3,80
3,52
2,82
4,28
3,21
3,43
2,24
2,78
2,76

2,15
2,77
4,02
4,29
4,37
4,02
3,65
4,58
5,80
4,68
4,51
3,84
4,59
4,25

Operating conditions **

V
380 V

kW

0,4
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22

1,96
2,37
3,03
4,24
5,58
8,14
10,7
13,5
18,2
25,2
36,1
47,1
59,2
69,1

Y
230 V

1,89
2,30
3,01
4,24
5,53
8,12
10,5
13,5
18,1
24,7
35,2
45,6
58,2
67,4

1,13
1,37
1,75
2,45
3,22
4,70
6,19
7,82
10,5
14,6
20,8
27,2
34,2
39,9

400 V
380 V
IN (A)

1,09
1,33
1,74
2,45
3,19
4,69
6,06
7,77
10,4
14,3
20,3
26,4
33,6
38,9

1,75
2,44
3,23
4,69
6,20
7,84
10,5
14,6
21,1
27,3
34,3
39,8

Y
400 V

660 V

Altitude
690 V

nN
min

Level (m)

1,00
1,40
1,86
2,70
3,53
4,49
6,02
8,16
12,0
15,2
19,4
22,0

3280 3335
3380 3415
3490 3500
3490 3505
3485 3505
3495 3505
3480 3495
3510 3520
3505 3515
3525 3535
3520 3540
3545 3550
3550 3555
3545 3555

-1

1,74
2,43
3,22
4,68
6,11
7,77
10,4
14,1
20,7
26,3
33,6
38,2

1,01
1,41
1,86
2,71
3,58
4,52
6,07
8,40
12,2
15,8
19,8
23,0

T. amb

above sea min/max


C

-15 / 40

220 V

cos

Voltage UN

PN

Hz

1000

60Hz

SM071RB14/304
SM071B14/305
SM080B14/307PE
SM080B14/311PE
SM090RB14/315PE
PLM090B14/322
PLM100RB14/330
PLM112RB14/340
PLM132RB5/355
PLM132B5/375
PLM160RB5/3110
PLM160B5/3150
PLM160B5/3185
PLM180RB5/3220

0,4
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22

N. of
Poles

V18/B14

Model

Data for 380 V / 60 Hz

V1/B5

PN
kW

MOTORS

IE

kW

Construction
Design

230 V

IEC SIZE*

PN

220 V

sv-ie2-mott22-2p60_d_te

* R =Reduced size of motor casing as compared to shaft extension and flange.


** Operating conditions to be referred to motor only. About electric pump, refer to limits in users manual.

228

e-SV
MOTORI SERIES
WEG 60 Hz, 2 poli
THREE-PHASE MOTORS A
T 60 Hz, 2-POLE (from 30 to 55 kW)
AT
Efficiency N
%
220 V
Y 380 V

PN

IE

4/4

3/4

2/4

30
37
45
55

92,4
92,4
93,5
93,5

92,4
92,4
93,0
93,5

91,5
92,0
91,8
92,8

IEC SIZE

Construction
Design

kW

PN

200
200
225
250

TN
cos

ls / lN

Nm

Ts/TN

Tm/Tn

60

0,86
0,86
0,89
0,89

6,40
7,20
7,80
7,70

80,65
98,98
120,5
147,0

2,10
2,40
2,20
2,20

2,40
2,60
2,90
2,80

Voltage UN

Operating conditions **

220 V

Altitude
nN

380 V
IN (A)

kW

99,0
122,0
142,0
173,0

30
37
45
55

57,3
70,7
82,2
100,0

** Operating conditions to be referred to motor only. About electric pump, refer to limits in users manual.

T. amb

above sea min/max

min-1

Level (m)

3550
3555
3560
3560

1000

PN

sv-ie2-mott55-2p60_b_te

RUMOROSITA' MOTORI SV 2-POLI 60Hz

MOTOR NOISE A
T 60 Hz, 2-POLE
AT
POWER

MOTOR TYPE

The table show the mean sound pressure (Lp) measured


as per Curve A (Standard ISO 1680).
Noise values were measured with the 60 Hz motor
running idle with a tolerance of 3 dB (A).

NOISE
LpA

kW

IEC SIZE*

dB

0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
45
55

71R
71
80-80R
80
90-90R
90
100R
112R
132R
132
160R
160
160
180R
200
200
225
250

<70
<70
<70
<70
<70
<70
<70
<70
<70
76
77
74
75
73
74
74
79
79

*R = Reduced motor casing size with respect


to shaft extension and related flange.

1-125sv_mott_2p60_c_tr

229

60Hz

W22 200L2-B5 30kW


W22 200L2-B5 37kW
W22 225S/M2-B5 45kW
W22 250S/M2-B5 55kW

fN
Hz

MOTORS

30
37
45
55

N. of
Poles

-15 / 40

Model

Data for 380 V / 60 Hz

V1/B5

kW

e-SV
MOTORI SERIES
TRIFASE PER SERIE 1-125SV Ie2 60 Hz, 4 poli .
THREE-PHASE MOTORS A
T 60 Hz, 4-POLE
AT
Efficiency N
%
380 V

400 V

Y 380 V

Y 400 V

Y 660 V

Y 690 V

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

4/4

3/4

2/4

0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15

83,2
84,0
84,5
87,5
87,5
87,9
89,5
89,5
91,0
91,0

82,3
84,0
84,5
87,5
87,5
87,9
89,5
89,5
91,0
91,0

78,4
81,0
82,5
85,7
84,7
87,6
88,7
89,2
91,0
90,4

83,2
84,0
84,5
87,5
87,5
87,9
89,5
89,5
91,0
91,0

82,3
84,0
84,5
87,5
87,5
87,9
89,5
89,5
91,0
91,0

78,4
81,0
82,5
85,7
84,7
87,6
88,7
89,2
91,0
90,4

83,2
84,0
84,5
87,5
87,5
87,9
89,5
89,5
91,0
91,0

82,3
84,0
84,5
87,5
87,5
87,9
89,5
89,5
91,0
91,0

78,4
81,0
82,5
85,7
84,7
87,6
88,7
89,2
91,0
90,4

83,2
84,0
84,5
87,5
87,5
87,9
89,5
89,5
91,0
91,0

82,3
84,0
84,5
87,5
87,5
87,9
89,5
89,5
91,0
91,0

78,4
81,0
82,5
85,7
84,7
87,6
88,7
89,2
91,0
90,4

60Hz

SM471B14/302
SM471B14/304
SM480B14/305
LLM480B14/307
PLM490B14/311
PLM490B14/315
PLM4100B14/322
PLM4100B14/330
PLM4112B5/340
PLM4132B5/355
PLM4132B5/375
PLM4160B5/3110
PLM4160B5/3150

0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15

71
71
80
80
90
90
100
100
112
132
132
160
160

N. of
Poles

fN

TN
cos

ls / lN

Nm

Ts/TN

Tm/Tn

60

0,68
0,68
0,77
0,75
0,71
0,68
0,76
0,72
0,78
0,78
0,79
0,85
0,82

3,45
3,52
3,55
6,26
6,70
7,19
8,01
8,19
8,48
7,85
7,84
7,25
8,17

1,45
2,17
3,18
4,14
6,01
8,18
12,0
16,3
21,8
29,8
40,8
59,4
80,7

2,37
2,65
1,80
2,82
2,57
3,04
2,69
2,98
3,01
2,61
2,43
2,27
2,65

2,15
2,05
1,90
3,53
3,60
3,74
4,33
4,28
4,22
3,48
3,59
3,07
3,64

Voltage UN

Operating conditions **

T. amb

380 V

400 V
380 V
IN (A)

400 V

660 V

690 V

nN
min-1

Level (m)

1,51
2,18
2,74
3,15
4,78
6,69
8,6
12,5
15,3
20,9
27,9
37,9
52,9

3,13
4,80
6,77
8,57
12,6
15,2
20,6
27,6
37,9
53,4

0,87
1,26
1,58
1,82
2,76
3,86
4,98
7,20
8,82
12,1
16,1
21,9
30,6

1,81
2,77
3,91
4,95
7,26
8,78
11,9
15,9
21,9
30,8

1,80
2,74
3,92
4,92
7,02
8,72
12,0
16,0
21,5
29,9

1,05
1,58
2,23
2,86
4,04
5,08
7,04
9,34
12,6
17,4

1,04
1,58
2,26
2,84
4,05
5,03
6,91
9,21
12,4
17,3

1650
1630
1650
1730 1735
1745 1750
1750 1755
1755 1760
1760 1765
1755 1755
1760 1765
1750 1755
1765 1770
1770 1775

-15 / 40

Altitude

230 V

kW

0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15

220 V

1000

PN

Hz

V18/B14

Model

Data for 380 V / 60 Hz

V1/B5

PN
kW

MOTORS

IE

kW

Construction
Design

230 V

IEC SIZE

PN

220 V

1,81
2,74
3,87
4,95
7,00
8,80
12,2
16,2
21,9
30,2

** Operating conditions to be referred to motor only. About electric pump, refer to limits in users manual.

230

abov. sea min/max

sv-ie2-mott-4p60-en_b_te

e-SV SERIES
MOTOR NOISE A
T 60 Hz, 4-POLE
AT
The table show the mean sound pressure (Lp) measured as per Curve A (Standard ISO 1680).
Noise values were measured with the 60 Hz motor running idle with a tolerance of 3 dB (A).

RUMOROSITA' MOTORI SV 4-POLI 60Hz

MOTORS A
T 60 Hz, 4-POLE
AT

0,25
0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15

NOISE

IEC

LpA

SIZE

dB

71
71
80
80
90
90
100
100
112
132
132
160
160

<70
<70
<70
<70
<70
<70
<70
<70
<70
<70
<70
<70
<70

1-125sv_mott-4p60_a_tr

60Hz

kW

MOTOR TYPE

MOTORS

POWER

231

AVAILABLE V
OL
TAGES
VOL
OLT
SM and PLM MOTORS FOR e-SV SERIES, 2-POLE
SINGLE-PHASE

THREE-PHASE

s = Standard voltage

3 x 380-400/660-690

3 x 440-460-480/-

3 x 110-115/190-200

3 x 200-208/346-360

3 x 330-346/575-600

3 x 575/-

3 x 230/400 50 Hz
3 x 265/460 60 Hz

3 x 400/690 50 Hz
3 x 460/- 60 Hz

o
o
o
o
-

3 x 255-265-277/440-460-480

o
o
-

3 x 220-230/380-400

o
o
o
o
o
-

3 x 500-525/-

o
o
-

3 x 440-460/-

1 x 200-210

s
s
s
s
s
s

3 x 290-300/500-525

1 x 120-127

o
o
o
o
-

3 x 255-265/440-460

1x 110-115

o
o
o
-

PN
kW

3 x 200-208/346-360

1 x 100

s
s
s
s
s
s

50/60 Hz

3 x 380-400-415/660-690

1 x 220-230

0,37
0,55
0,75
1,1
1,5
2,2

60 Hz

3 x 220-230-240/380-400-415

PN
kW

1 x 110-120

50 Hz

1 x 100

60 Hz

1 x 220-240

50 Hz

0,37
0,55
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22

s
s
s
s
s
s
s
o
o
o
o
o
o
o

o
o
o
o
o
o
o
s
s
s
s
s
s
s

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

s
s
s
s
s
s
s
s
s
s
s
s
s
s

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o
o
o

o = voltage upon request

- = Not available

sv-volt-lowa-en_b_te

W22 MOTORS FOR e-SV SERIES, 2-POLE


THREE-PHASE

PN
kW

3 x 110/190

3 x 200-208/346-360

3 x 255-265/440-460

3 x 290-300/500-525

3 x 440-460/-

3 x 500-525/-

3 x 230/380

3 x 380-400/660-690

3 x 440-480/-

3 x 110-115/190-200

3 x 200-208/346-360

3 x 255-265-277/440-460-480

3 x 330-346/575-600

3 x 575/-

3 x 230/400 50 Hz
3 x 265/460 60 Hz

3 x 400/690 50 Hz
3 x 460/- 60 Hz

50/60 Hz

3 x 380-400-415/660-690

60 Hz

3 x 220-230-240/380-400-415

MOTORS

50 Hz

30
37
45
55

o
o
o
o

s
s
s
s

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

s
s
s
s

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

s = Standard voltage

o = voltage upon request

- = Not available

232

sv-volt-weg-en_c_te

SENSOR

PROTECTION
SENSOR
AGAINST DRY
RUNNING

233

PROTECTION SENSOR AGAINST DRY RUNNING


Sensor for detecting the presence of water based on the optoelectronic
principle, therefore non-invasive and with no moving parts. The sensor features
an electronic contact (on/off) which stops the pump if there is no water in
the seal area.
The sensor opens the electric contact if there is no water after they factoryset delay (10 seconds) elapses. The sensor is supplied as a kit complete with
2 metres of cable, an EPDM O-ring gasket and a stainless steel adapter.
General operating features
The sensor can be fitted directly on the filling cap of the e-SVTM series of pumps.
Operation is independent of the hardness and conductivity of the water. The sensor cannot detect frozen liquids.

Available in two power versions depending on foreseen use:


2127 Vac, universal solid state output for external relay at 24 Vac (2127 Vac, 50 mA).
1525 Vdc, NPN output at 25 V (10 mA) for HYDROVARTM inverter.

Operating principle
Operation is based on the change in the
refractive index on the surfaces.
The optic sensor comprises a glass cap
(C) containing a transmitter (T) and an
infrared receiver (R).

If there is no liquid, all the infrared light


emitted by the transmitter is internally
reflected by the surface of the glass cap
of the receiver.
The electronic contact will be open,

If liquid is present, the refractive index of


the surface changes. Most of the
infrared light emitted by the transmitter
is dispersed in the liquid.
The receiver receives less light and the
electronic contact is closed.
SOL_M0005_A_SC

R
C

SENSOR

SPECIFICA
TIONS
SPECIFICATIONS
Materials:
- Body in AISI 316L stainless steel
- Glass optic cap
- EPDM gasket
Liquids: clean water, demi water. Operation is not affected by the hardness and conductivity of the liquid. To check the suitably
of other liquids, contact the Lowara technical assistance service providing the characteristics of the liquid.
Temperature of liquid: -20C+120C (cannot be used to detect frozen liquids).
Ambient temperature: -5C +50C
Maximum pressure (PN): 25 bar
Connector: 3/8 (3/8 x 1/2 adaptor plug included in the Kit)
Dimensions: 27x 60 mm
IP55 protection
Electrical characteristics:
- Input voltage SENSOR KIT DRP-GP: 2127 Vac
SENSOR KIT DRP-HV: 1525 Vdc
- Output
SENSOR KIT DRP-GP: universal solid state 2127 Vac (50 mA) for 24 Vac external relay
SENSOR KIT DRP-HV: NPN 25 V (10 mA) for HYDROVARTM inverter
- Alarm delay: 10 seconds (factory setting)
- FROR cable 4 x 0,34 mm2 (PVC-CEI 20-22) 2 metres long.

234

WIRING DIAGRAM
The sensor can be directly mounted on the filling plug of the e-SVTM pumps.
For the 33, 46, 66, 92, 125SV series, the 3/8" x 1/2" adaptor ring included in the Kit must also be mounted.
SENSOR KIT DRP
-GP (code 109394610)
DRP-GP
CH 24

CH 27

50 mm

3/8"
< 50 mm

1/2"

max 20 Nm

1-22 SV

33-125 SV
BN

I max = 50 mA
BK
BU

GND

WH

FIG.1

SOL_M0001_A_SC

SENSOR KIT DRP


-HV (code 109394600)
DRP-HV
CH 24

CH 27

FIG.1

3/8"

1/2"

50 mm

max 20 Nm

BK

1 2 3 4 5

BN
WH

X3

BN
Brown

BU
Blue

WH
White

235

BU
BK
BN

23 24

24 V

BU

9 10 11 12

GND

X1

BK
Black

HV 2.015g 4.110g

13

1 2 3 4 5 6 7 8 9

15 V

GND

33-125 SV

1-22 SV

HV 2.1f 3.11f
HV 3.15e 3.45e

SENSOR

< 50 mm

X1, X3
Terminal board

WH

X
SOL_M0004_A_SC

236

SENSOR

i-ALERT

i-ALERT

i-ALERT
VIBRATION
MONITOR

237

SERIE e-SV
e-SV
i-ALERT
TION MONITOR
i-ALERT - VIBRA
VIBRATION
Patented system which constantly measures vibrations and signals any operating
faults that could break the pump. Available standard in e-SVTM electric pumps
with nominal power outputs greater than 5,5 kW (7,5 HP).
Available on request in e-SVTM electric pumps with nominal power outputs
less than or equal to 5,5 kW (7,5 HP).

Operating principle
The device measures the level of vibrations at five minute intervals. If the set limit* is exceeded at least three times
consecutively, the device switches to the alarm mode, reduces the measurement interval to two minutes and
activates the relative flashing signal. If the fault is temporary, the device automatically returns to the normal mode
after measuring at least one vibration value within the set limit*.

SPECIFICA
TIONS
SPECIFICATIONS

i-ALERT

i-ALERT

The device is fixed to the motor adapter of the e-SVTM pumps.


The device features a flashing green light LED indicating that it is in the normal mode and that the battery is
sufficiently charged.
It constantly measures the vibration level and assess the responses from the motor and pump during operation.
If the set limit is exceeded*, the two red LEDs on the device flash to warn the user. This allows action to be taken
before a fault or damage occurs to the pump.
Vibration limit* for tripping the alarm:
equal to twice the average vibration level during normal operation
with a minimum of 3,175 mm/s (to reduce the possibility of false alarms)
with a maximum of 12,7 mm/s (Hydraulic Institute Standard, ISO 10816)
Measurement interval:
5 minutes when the device is in the normal mode.
2 minutes when the device is in the alarm mode.
Power supplied by an internal lithium battery which cannot be replaced; when it goes flat, the entire device must be
replaced. Its lifetime varies (1-3 years) depending on the number of times it enters the alarm mode.
Ambient temperature: maximum 90C.
Atmosphere: unsuitable for atmospheres containing acetic acid.

238

SERIE e-SV
e-SV
i-ALERT
TION MONITORING
i-ALERT - VIBRA
VIBRATION

A: Green LED
B: Red LED

B
A

i-ALERT

i-ALERT

ALERT_M0002_A_SC

239

240

i-ALERT

i-ALERT

REPORTS

REPORTS AND
DECLARATIONS

241

REPORTS AND DECLARA


TIONS
DECLARATIONS
i)

T
est reports
Test

a)

F
actory T
est Report (Lowara identity code: 1A)
Factory
Test
(not available for all pump types; contact Customer Service in advance)
- Test report compiled at the end of the assembly line, including flow-head performance test
(ISO 9906:2012 Grade 3B) and tightness test.

b)

Audit T
est Report (Lowara identity code: 1B)
Test
- Test report for electric pumps compiled in the test room, comprising flow-head-pump input-pump efficiency
performance test (ISO 9906:2012 Grade 3B)

c)

NPSH T
est Report (Lowara identity code: 1A / CTF-NP)
Test
(unavailable for submerged or submergible pumps)
- Test report for electric pumps compiled in the test room, comprising flow-NPSH performance test
(ISO 9906:2012 Grade 3B)

d)

Noise T
est Report (Lowara identity code: 1A / CTF-RM)
Test
(unavailable for submerged pumps)
- Report indicating sound pressure and power measurements (EN ISO 20361, EN ISO 11203, EN ISO 4871)
using the
intensimetric (EN ISO 9614-1, EN ISO 9614-2), or
phonometric method.

e)

ibration T
est Report
V
Test
Vibration
(unavailable for submerged or submergible pumps)
- Report indicating vibration measurements (ISO 10816-1)

ii)

Declaration of product conformity with the technical requirements indicated in the


order

a)

EN 10204:2004 - type 2.1 (Lowara identity code: CTF-21)


- does not include test results on supplied or similar products.

b)

EN 10204:2004 - type 2.2 (Lowara identity code: CTF-22)


- includes test results (materials certificates) on similar products.

c)

EN 10204:2004 - type 3.1 (Lowara identity code: 1A / CTF-31 or 1B / CTF-31)


- includes test report (Factory Test Report or Audit Test Report), list of materials, EC Declaration of Conformity
(in addition to the one accompanying the product), certificates / declarations concerning materials in contact
with water.

iii) Issue of a further EC Declaration of Conformity


Conformity,,
- in addition to the one accompanying the product, it comprises references to European law and the main
technical standards (e.g.: MD 2006/42/EC, EMCD 2004/108/EC, ErP 2009/125/EC).

REPORTS

N.B.: if the request is made after receipt of the product, communicate the code (name) and serial number
(date + progressive number).
iv) Manufacturer
s declaration of conformity
Manufacturers
- relative to one of more types of products without indicating specific codes and serial numbers.
v)

Other certificates and/or documentation on request


- subject to availability or feasibility.

vi) Duplication of certificates and/or documentation on request


- subject to availability or feasibility.

242

AC
CES
SORIES
ACCES
CESSORIES

ACCESSORIES

243

G/SVH KIT
TABLE OF SIZES
SVH series electric pump with hydraulic kit and G/SVH accessories, to realise a single-pump booster set which is
quick and easy to install.
The hydraulic kit can be combined with the following SHV electric pumps:
- F versions (in-line ports, round flanges)
- R versions (overlapping ports, round flanges)
- N versions (in-line ports round flanges)
- G versions (in-line ports round flanges)
Assembly instructions inside the kit pack.

1-22SV

33-92SV

AC
CES
SORIES
ACCES
CESSORIES

DIMENSIONI E PESI SERIE G - SV 2 poli 50 Hz


TYPE

G/SVH DN25 PN25


G/SVH DN32 PN25
G/SVH DN40 PN25
G/SVH DN50 PN25
G/SVH DN65 PN16
G/SVH DN65 PN25
G/SVH DN80 PN16
G/SVH DN80 PN25
G/SVH DN100 PN16
G/SVH DN100 PN25

PUMP

1SV - 3SV
5SV
10SV
15SV - 22SV
33SV
33SV
46SV
46SV
66SV - 92SV
66SV - 92SV

DIMENSIONS (mm)

DRW.
N

DN

PN

1
1
1
1
2
2
2
2
2
2

25
32
40
50
65
65
80
80
100
100

25
25
25
25
16
25
16
25
16
25

180
180
185
195
105
105
140
140
140
140

524
521
557
637
662
674
711
723
744
744

744
748
756
772
690
690
732
732
744
744

Same dimensions for STANDARD, A304 and A316 versions.

g-sv-2p50-en_a_td

244

G/SVH KIT
TABLE OF COMPONENTS

1-22SV

33-125SV

(1)
PUMP TYPE

kW

1SVH15..007

0,75

1SVH22..011
1SVH30..015
1SVH37..022
3SVH08..007
3SVH12..011

1,1
1,5
2,2
0,75
1,1

3SVH16..015

1,5

3SVH21..022

2,2

3SVH25..022

2,2

3SVH29..030

5SVH05..007

0,75

5SVH08..011

1,1

5SVH11..015

1,5

5SVH14..022

2,2

5SVH16..022

2,2

5SVH21..030
5SVH28..040
5SVH33..055

VOLTAGE

(2)
ELECTRIC
PANEL

(3)
HYDRAULIC
STD KIT

(3)
HYDRAULIC
A304 KIT

(3)
HYDRAULIC
A316 KIT

(4)
MEMBRANE
TANK STD KIT

(4)
MEMBRANE
TANK A304 KIT

109391561

1x230 V

108212100

109422101

109422113

109422125

109391560

3x400 V

108212300

109422101

109422113

109422125

109391560

1x230 V

108212100

109422101

109422113

109422125

109391570

3x400 V

108212300

109422101

109422113

109422125

109391570

1x230 V

108212100

109422101

109422113

109422125

109395050

3x400 V

108212300

109422101

109422113

109422125

109395050

1x230 V

108212100

109422101

109422113

109422125

109395050

3x400 V

108212300

109422101

109422113

109422125

109395050

1x230 V

108212100

109422101

109422113

109422125

109391560

109391561

3x400 V

108212300

109422101

109422113

109422125

109391560

109391561

1x230 V

108212100

109422101

109422113

109422125

109391560

109391561
109391561

3x400 V

108212300

109422101

109422113

109422125

109391560

1x230 V

108212100

109422101

109422113

109422125

109391570

3x400 V

108212300

109422101

109422113

109422125

109391570

1x230 V

108212100

109422101

109422113

109422125

109391570

3x400 V

108212300

109422101

109422113

109422125

109391570

1x230 V

108212100

109422101

109422113

109422125

109395050

3x400 V

108212300

109422101

109422113

109422125

109395050

3x400 V

108212300

109422101

109422113

109422125

109395050

3x400 V

108212300

109422101

109422113

109422125

109395050

1x230 V

108212100

109422102

109422114

109422126

109391560

109391561

3x400 V

108212300

109422102

109422114

109422126

109391560

109391561

1x230 V

108212100

109422102

109422114

109422126

109391560

109391561

3x400 V

108212300

109422102

109422114

109422126

109391560

109391561

1x230 V

108212100

109422102

109422114

109422126

109391560

109391561

3x400 V

108212300

109422102

109422114

109422126

109391560

109391561

1x230 V

108212100

109422102

109422114

109422126

109391570

3x400 V

108212300

109422102

109422114

109422126

109391570

1x230 V

108212100

109422102

109422114

109422126

109391570

3x400 V

108212300

109422102

109422114

109422126

109391570

3x400 V

108212300

109422102

109422114

109422126

109391570

3x400 V

108212300

109422102

109422114

109422126

109395050

5,5

3x400 V

108212400

109422102

109422114

109422126

109395050

1-5G_SVH-en_a_tc

245

AC
CES
SORIES
ACCES
CESSORIES

1) SVH series electric pump


2) electric safety panel
3) hydraulic kit with support base, flanges, manifold and panel mounting bracket
4) idrotuba tank and ball valve kit
N.B.: the support base for the electric pump is suitable for up to and including the 22SV model.

G/SVH KIT
TABLE OF COMPONENTS
(1)
PUMP TYPE

kW

10SVH04..015

1,5

(2)
ELECTRIC
PANEL

(3)
HYDRAULIC
STD KIT

(3)
HYDRAULIC
A304 KIT

(3)
HYDRAULIC
A316 KIT

(4)
MEMBRANE
TANK STD KIT

(4)
MEMBRANE
TANK A304 KIT

1x230 V

108212100

109422103

109422115

109422127

109391560

109391561

3x400 V

108212300

109422103

109422115

109422127

109391560

109391561

1x230 V

108212100

109422103

109422115

109422127

109391560

109391561

3x400 V

108212300

109422103

109422115

109422127

109391560

109391561

10SVH06..022

2,2

10SVH08..030

3x400 V

108212300

109422103

109422115

109422127

109391560

109391561

10SVH11..040

3x400 V

108212300

109422103

109422115

109422127

109391570

10SVH15..055

5,5

3x400 V

108212400

109422103

109422115

109422127

109395050

10SVH20..075

7,5

3x400 V

108212500

109422103

109422115

109422127

109395050

10SVH21..110

11

3x400 V

108212600

109422103

109422115

109422127

109395050

1x230 V

108212100

109422104

109422116

109422128

109391560

109391561

3x400 V

108212300

109422104

109422116

109422128

109391560

109391561

15SVH02..022

AC
CES
SORIES
ACCES
CESSORIES

VOLTAGE

2,2

15SVH03..030

3x400 V

108212300

109422104

109422116

109422128

109391560

109391561

15SVH05..040

3x400 V

108212300

109422104

109422116

109422128

109391560

109391561

15SVH07..055

5,5

3x400 V

108212400

109422104

109422116

109422128

109391570

15SVH09..075

7,5

3x400 V

108212500

109422104

109422116

109422128

109391570

15SVH13..110

11

3x400 V

108212600

109422104

109422116

109422128

109395050

15SVH17..150

15

3x400 V

108212700

109422104

109422116

109422128

109395050

1x230 V

108212100

109422104

109422116

109422128

109391560

109391561

22SVH01..011

1,1

3x400 V

108212300

109422104

109422116

109422128

109391560

109391561

22SVH03..030

3x400 V

108212300

109422104

109422116

109422128

109391560

109391561

22SVH04..040

3x400 V

108212300

109422104

109422116

109422128

109391560

109391561

22SVH05..055

5,5

3x400 V

108212400

109422104

109422116

109422128

109391560

109391561

22SVH07..075

7,5

3x400 V

108212500

109422104

109422116

109422128

109391570

22SVH10..110

11

3x400 V

108212600

109422104

109422116

109422128

109391570

22SVH14..150

15

3x400 V

108212700

109422104

109422116

109422128

109395050

33SVH1/1A..022

2,2

1x230 V

108212100

109422105

109422117

109422129

109391560

109391561

33SVH1..030

3x400 V

108212300

109422105

109422117

109422129

109391560

109391561

33SVH2..055

5,5

3x400 V

108212400

109422105

109422117

109422129

109391560

109391561

33SVH3..075

7,5

3x400 V

108212500

109422105

109422117

109422129

109391560

109391561

33SVH4..110

11

3x400 V

108212600

109422105

109422117

109422129

109391570

33SVH5..150

15

3x400 V

108212700

109422105

109422117

109422129

109391570

33SVH6..150

15

3x400 V

108212700

109422106

109422118

109422130

109391570

33SVH7..185

18,5

3x400 V

108212900

109422106

109422118

109422130

109395050

46SVH1..040

3x400 V

108212300

109422107

109422119

109422131

109391560

109391561

46SVH2..075

7,5

3x400 V

108212500

109422107

109422119

109422131

109391560

109391561

46SVH3..110

11

3x400 V

108212600

109422107

109422119

109422131

109391560

109391561

46SVH4..150

15

3x400 V

108212700

109422107

109422119

109422131

109391570

46SVH6..220

22

3x400 V

108212900

109422108

109422120

109422132

109391570

66SVH1..055

5,5

3x400 V

108212400

109422109

109422121

109422133

109391560

109391561

66SVH2..110

11

3x400 V

108212600

109422109

109422121

109422133

109391560

109391561

66SVH3..185

18,5

3x400 V

108212900

109422109

109422121

109422133

109391570

66SVH4..220

22

3x400 V

108212900

109422109

109422121

109422133

109391570

92SVH1..075

7,5

3x400 V

108212500

109422109

109422121

109422133

109391560

109391561

92SVH2..150

15

3x400 V

108212700

109422109

109422121

109422133

109391560

109391561

3x400 V

108212900

109422109

109422121

109422133

109391570

92SVH3..220

22

10-125G_SVH-en_a_tc

246

THREADED COUNTERFLANGES KIT (F


(F,, N, R
R,, G SV) EN 1092-1

Kit containing 2 counterflanges with bolts and gaskets.


- threaded, galvanized steel (F, R, G versions).
- threaded, AISI 316L stainless steel (N versions).

CODICI KIT CONTROFLANGE TONDE FILETTATE per SV


DESCRIPTION

HOLES

TYPE

DN

PN

25

Rp 1

85

10

115

16

14

25

109398000

KIT RP1" PN25 GALVANIZED STEEL

1-3SV

109398002

KIT RP1" PN25 AISI 316

1-3SV

25

Rp 1

85

10

115

16

14

25

109398010

KIT RP1"1/4 PN25 GALVANIZED STEEL

5SV

32

Rp 1

100

13

140

16

18

25

109398012

KIT RP1"1/4 PN25 AISI 316

5SV

32

Rp 1

100

13

140

16

18

25

109398020

KIT RP1"1/2 PN25 GALVANIZED STEEL

10SV

40

Rp 1

110

14

150

19

18

25

109398022

KIT RP1"1/2 PN25 AISI 316

10SV

40

Rp 1

110

14

150

19

18

25

109398030

KIT RP2" PN25 GALVANIZED STEEL

15-22SV

50

Rp 2

125

16

165

24

18

25

109398032

KIT RP2" PN25 AISI 316

15-22SV

50

Rp 2

125

16

165

24

18

25

109392710

KIT RP2"1/2 PN16 GALVANIZED STEEL

33SV

65

Rp 2

145

16

185

23

18

16

109392750

KIT RP2"1/2 PN16 AISI 316

33SV

65

Rp 2

145

16

185

23

18

16

109392720

KIT RP3" PN16 GALVANIZED STEEL

46SV

80

Rp 3

160

17

200

27

18

16

109392760

KIT RP3" PN16 AISI 316

46SV

80

Rp 3

160

17

200

27

18

16

109392730

KIT RP4" PN16 GALVANIZED STEEL

66SV-92SV 100

Rp 4

180

18

220

31

18

16

109392770

KIT RP4" PN16 AISI 316

66SV-92SV 100

Rp 4

180

18

220

31

18

16

kit_flg_fil-en_a_td

247

AC
CES
SORIES
ACCES
CESSORIES

DIMENSIONS (mm)

PUMP
P.NUMBER

WELD
-ON ROUND COUNTERFLANGES KIT (G, N SV) EN 1092-1
WELD-ON

Kit containing 2 counterflanges with bolts and gaskets.


- weld-on counterflanges, galvanized steel (G versions).
- weld-on counterflanges, AISI 316L stainless steel (N versions).

CODICI KIT CONTROFLANGE TONDE A SALDARE per SV


DIMENSIONS (mm)

PUMP

AC
CES
SORIES
ACCES
CESSORIES

P.NUMBER

DESCRIPTION

HOLES

TYPE

DN

PN

109392800

KIT DN65 PN16 GALVANIZED STEEL

33SV

65

77

145

18

185

18

16

109392880

KIT DN65 PN16 AISI 316

33SV

65

77

145

18

185

18

16

109392840

KIT DN65 PN25-40 GALVANIZED STEEL

33SV

65

77

145

18

185

18

25-40

109392920

KIT DN65 PN25-40 AISI 316

33SV

65

77

145

18

185

18

25-40

109392810

KIT DN80 PN16 GALVANIZED STEEL

46SV

80

90

160

20

200

18

16

109392890

KIT DN80 PN16 AISI 316

46SV

80

90

160

20

200

18

16

109392850

KIT DN80 PN25-40 GALVANIZED STEEL

46SV

80

90

160

20

200

18

25-40

109392930

KIT DN80 PN25-40 AISI 316

46SV

80

90

160

20

200

18

25-40

109392820

KIT DN100 PN16 GALVANIZED STEEL

66-92SV

100

115,5

180

22

220

18

16

109392900

KIT DN100 PN16 AISI 316

66-92SV

100

115,5

180

22

220

18

16

109392860

KIT DN100 PN25-40 GALVANIZED STEEL

66-92SV

100

115,5

180

22

220

22

25-40

109392940

KIT DN100 PN25-40 AISI 316

66-92SV

100

115,5

180

22

220

22

25-40

109398080

KIT DN125 PN16 GALVANIZED STEEL

125SV

125

141

210

24

250

18

16

109398082

KIT DN125 PN16 AISI 316

125SV

125

141

210

24

250

18

16

109398090

KIT DN125 PN25-40 GALVANIZED STEEL

125SV

125

141

220

28

270

26

25-40

109398092

KIT DN125 PN25-40 AISI 316

125SV

125

141

220

28

270

26

25-40

kit_flg_sald-en_a_td

248

VICT
AULIC COUPLINGS KIT (V SV)
VICTA
MAXIMUM OPERA
TING PRES
SURE 6900 kP
a
OPERATING
PRESSURE
kPa

The single Kit includes: One cast iron Victaulic coupling with one AISI 316L stainless steel weld-on
or threaded sleeve with EPDM or FPM gasket.
The double Kit includes: Two cast iron Victaulic couplings with two AISI 316L stainless steel weld-on
or threaded sleeve with EPDM or FPM gasket.

DIMENSIONI GIUNTI VICTAULIC 1-22 SV PRESSIONE MASSIMA DI ESERCIZIO 6900k


DESCRIPTION

TYPE

DN

1-3-5SV V

DN32

R 1"1/4

320

75

109390880

KIT SINGLE VICTAULIC THREADED R 1"1/4 EPDM

109390980
109390890
109390990

KIT SINGLE VICTAULIC THREADED R 1"1/4 FPM


KIT SINGLE VICTAULIC THREADED R 2" EPDM
KIT SINGLE VICTAULIC THREADED R 2" FPM

1-3-5SV V
10-15-22SV V
10-15-22SV V

DN32
DN50
DN50

R 1"1/4
R 2"
R 2"

320
378
378

75
90
90

109390860

KIT SINGLE VICTAULIC DN32 WELD-ON EPDM

1-3-5SV V

DN32

42,2

320

75

109390960

KIT SINGLE VICTAULIC DN32 WELD-ON FPM

1-3-5SV V

DN32

42,2

320

75

109390870

KIT SINGLE VICTAULIC DN50 WELD-ON EPDM

10-15-22SV V

DN50

60,3

378

90

109390970

KIT SINGLE VICTAULIC DN50 WELD-ON FPM

10-15-22SV V

DN50

60,3

378

90

109398400

KIT DOUBLE VICTAULIC THREADED R 1"1/4 EPDM

1-3-5SV V

DN32

R 1"1/4

320

75

109398401

KIT DOUBLE VICTAULIC THREADED R 1"1/4 FPM

1-3-5SV V

DN32

R 1"1/4

320

75

109398410

KIT DOUBLE VICTAULIC THREADED R 2" EPDM

10-15-22SV V

DN50

R 2"

378

90

109398411

KIT DOUBLE VICTAULIC THREADED R 2" FPM

10-15-22SV V

DN50

R 2"

378

90

109398420

KIT DOUBLE VICTAULIC DN32 WELD-ON EPDM

1-3-5SV V

DN32

42,2

320

75

109398421

KIT DOUBLE VICTAULIC DN32 WELD-ON FPM

1-3-5SV V

DN32

42,2

320

75

109398430

KIT DOUBLE VICTAULIC DN50 WELD-ON EPDM

10-15-22SV V

DN50

60,3

378

90

109398431

KIT DOUBLE VICTAULIC DN50 WELD-ON FPM

10-15-22SV V

DN50

60,3

378

90

1-22sv-giunti-vict-en_b_td

249

AC
CES
SORIES
ACCES
CESSORIES

DIMENSIONS (mm)

PUMP
P.NUMBER

VICT
AULIC COUPLINGS T
ANDEM KIT (SV P)
VICTA
TANDEM
MAXIMUM OPERA
TING PRES
SURE 6900 kP
a
OPERATING
PRESSURE
kPa

The kit includes: Two cast iron Victaulic couplings with AISI 316L

KIT TANDEM VICTAULIC


(V SV)
DI ESERCIZIO 6900kPa
stainless steel flanged
pipe PRESSIONE
with EPDM or FPMMASSIMA
gasket.
DIMENSIONS (mm)

PUMP
P.NUMBER

DESCRIPTION

TYPE

DN

109398250

KIT TANDEM VICTAULIC DN32 EPDM

1-3-5SV V

DN32

134

350

75

109398251
109398260
109398261

KIT TANDEM VICTAULIC DN32 FPM


KIT TANDEM VICTAULIC DN50 EPDM
KIT TANDEM VICTAULIC DN50 FPM

1-3-5SV V
10-15-22SV V
10-15-22SV V

DN32
DN50
DN50

134
183
183

350
450
450

75
90
90

AC
CES
SORIES
ACCES
CESSORIES

ROUND COUNTERFLANGES T
ANDEM KIT (SV P)
TANDEM
MAXIMUM OPERA
TING PRES
SURE 4500 kP
a
OPERATING
PRESSURE
kPa

kit_tandem_vict-en_b_td

The kit includes: One AISI 316L stainless steel flanged


pipe with AISI
bolts and gaskets.
KIT TANDEM ROUND
PRESSIONE
MASSIMA DI ESERCIZIO 4000kPa
DIMENSIONS (mm)

PUMP
P.NUMBER

DESCRIPTION

TYPE

DN

109398300

KIT TANDEM ROUND FLANGE DN65

33SV

DN65

176

500

105

109398310
109398320
109398330

KIT TANDEM ROUND FLANGE DN80


KIT TANDEM ROUND FLANGE DN100
KIT TANDEM ROUND FLANGE DN125

46SV
66-92SV
125SV

DN80
DN100
DN125

231
281
316

600
650
800

140
140
160

kit_tandem_round_flg_en_b_td

250

THREADED
CLAMP KIT

The Kit includes: Two AISI stainless steel Clamp couplings with AISI 316L stainless steel threaded sleeves

KIT GIUNTI CLAMP


FILETTATI
(C SV)
with EPDM
or FPM gaskets.
Coupling dimensions and profile according to DIN 32676.
DIMENSIONS (mm)

PUMP
DESCRIPTION

TYPE

DN

D6

109391860

KIT CLAMP DN32 THREADED RP 1"1/4 EPDM

1-3-5SV C

DN32

245

Rp 1

109391870
109391900
109391910

KIT CLAMP DN32 THREADED RP 1"1/4 FPM


KIT CLAMP DN50 THREADED RP 2" EPDM
KIT CLAMP DN50 THREADED RP 2" FPM

1-3-5SV C
10-15-22SV C
10-15-22SV C

DN32
DN50
DN50

245
301
301

Rp 1
Rp 2
Rp 2
kit-clamp_fill-en_a_td

WELD
-ON
WELD-ON
CLAMP KIT

AC
CES
SORIES
ACCES
CESSORIES

P.NUMBER

The Kit includes: Two AISI stainless steel Clamp couplings with AISI 316L stainless steel weld-on sleeves

KIT GIUNTI CLAMP


A SALDARE
(CCoupling
SV) dimensions and profile according to DIN 32676.
with EPDM
or FPM gaskets.
DIMENSIONS (mm)

PUMP
P.NUMBER

DESCRIPTION

TYPE

DN

D6

109391880

KIT CLAMP DN32 WELD-ON EPDM

1-3-5SV C

DN32

245

35

109391890
109391920
109391930

KIT CLAMP DN32 WELD-ON FPM


KIT CLAMP DN50 WELD-ON EPDM
KIT CLAMP DN50 WELD-ON FPM

1-3-5SV C
10-15-22SV C
10-15-22SV C

DN32
DN50
DN50

245
301
301

35
53
53
kit-clamp_sald-en_a_td

251

HORIZONT
AL INST
ALLA
TION BRACKET KIT (SV)
HORIZONTAL
INSTALLA
ALLATION

includes: Painted steel brackets


with galvanized steel bolts.
KITThe
SVKitINSTALLAZIONE
ORIZZONTALE
P.NUMBER

DESCRIPTION

MOTOR TYPE

148996700

BRACKET KIT 1-3-5SV F-N

148996710

BRACKET KIT 10-15-22SV F-N (0,7511 kW)

148990700

BRACKET KIT 33SV G-N (1,111 kW)

148990760
148990770
148996800

BRACKET KIT 46SV G-N (1,111 kW)


BRACKET KIT 66-92SV G-N (1,111 kW)
BRACKET KIT 125SV G-N (7,5 kW)

LOWARA

AC
CES
SORIES
ACCES
CESSORIES

148996700-en_b_td

includes: Painted steel brackets


with galvanized steel bolts.
KITThe
SVKitINSTALLAZIONE
ORIZZONTALE
P.NUMBER

DESCRIPTION

MOTOR TYPE

148990920

BRACKET KIT 33SV G-N (1522 kW)

148990730
148990930
148990800

BRACKET KIT 33SV G-N (22 kW)


BRACKET KIT 46-66-92SV G-N (1522 kW)
BRACKET KIT 46-66-92SV G-N (22 kW)

LOWARA

148996810

BRACKET KIT 125SV G-N (1522 kW)

148996850

BRACKET KIT 125SV G-N (22 kW)

148996820

BRACKET KIT 125SV G-N (3037 kW)

* WEG B35 SIZE 200

148996830

BRACKET KIT 125SV G-N (45 kW)

* WEG B35 SIZE 225

STANDARD B35 SIZE 180 (22kW)


LOWARA
STANDARD B35 SIZE 180 (22kW)
LOWARA
STANDARD B35 SIZE 180 (22kW)

* FOR THESE MODELS CHANGE THE MOTOR FROM V1/B5 TO B35 CONSTRUCTION DESIGN.

148990920-en_b_td

252

HORIZONT
AL INST
ALLA
TION BRACKET KIT (SV)
HORIZONTAL
INSTALLA
ALLATION

includes: Painted steel brackets with galvanized steel bolts.


KITThe
SVKitINSTALLAZIONE
ORIZZONTALE
P.NUMBER

DESCRIPTION

MOTOR TYPE

148996720

BRACKET KIT 15-22SV F-N (1518,5 kW)

LOWARA

148990740
148996750
148990810

BRACKET KIT 33SV F-N (kW3037)


BRACKET KIT 33SV G-N (3037 kW)
BRACKET KIT 46-66-92SV F-N (kW3037)

MARELLI SIZE 200


* WEG B35 SIZE 200
MARELLI SIZE 200

148996760

BRACKET KIT 46-66-92SV G-N (3037 kW)

* WEG B35 SIZE 200

148990820

BRACKET KIT 46-66-92SV F-N (kW45)

MARELLI SIZE 225

148996770

BRACKET KIT 46-66-92SV G-N (45 kW)

* WEG B35 SIZE 225

148996840

BRACKET KIT 125SV G-N (55 kW)

* WEG B35 SIZE 250

* FOR THESE MODELS CHANGE THE MOTOR FROM V1/B5 TO B35 CONSTRUCTION DESIGN.

AC
CES
SORIES
ACCES
CESSORIES

148996720-en_b_td

253

254

AC
CES
SORIES
ACCES
CESSORIES

TECHNICAL
APPENDIX

TECHNICAL
APPENDIX

255

NPSH
The minimum operating values that can be reached at the
pump suction end are limited by the onset of cavitation.
Cavitation is the formation of vapour-filled cavities within
liquids where the pressure is locally reduced to a critical value,
or where the local pressure is equal to, or just below the
vapour pressure of the liquid.
The vapour-filled cavities flow with the current and
when they reach a higher pressure area the vapour
contained in the cavities condenses. The cavities collide,
generating pressure waves that are transmitted to the
walls. These, being subjected to stress cycles, gradually
become deformed and yield due to fatigue. This
phenomenon, characterized by a metallic noise
produced by the hammering on the pipe walls, is called
incipient cavitation.
The damage caused by cavitation may be magnified by
electrochemical corrosion and a local rise in
temperature due to the plastic deformation of the
walls. The materials that offer the highest resistance to
heat and corrosion are alloy steels, especially austenitic
steel. The conditions that trigger cavitation may be
assessed by calculating the total net suction head,
referred to in technical literature with the acronym
NPSH (Net Positive Suction Head).
The NPSH represents the total energy (expressed in m.)
of the liquid measured at suction under conditions of
incipient cavitation, excluding the vapour pressure
(expressed in m.) that the liquid has at the pump inlet.
To find the static height hz at which to install the
machine under safe conditions, the following formula
must be verified:

TECHNICAL
APPENDIX

hp + hz (NPSHr + 0.5) + hf + hpv

where:
hp is the absolute pressure applied to the free liquid
surface in the suction tank, expressed in m. of
liquid; hp is the quotient between the barometric
pressure and the specific weight of the liquid.
hz is the suction lift between the pump axis and the
free liquid surface in the suction tank, expressed
in m.; hz is negative when the liquid level is
lower than the pump axis.
hf is the flow resistance in the suction line and its
accessories, such as: fittings, foot valve, gate
valve, elbows, etc.
hpv is the vapour pressure of the liquid at the
operating temperature, expressed in m. of
liquid. hpv is the quotient between the Pv vapour
pressure and the liquids specific weight.
0,5 is the safety factor.

The maximum possible suction head for installation


depends on the value of the atmospheric pressure
(i.e. the elevation above sea level at which the pump
is installed) and the temperature of the liquid.
To help the user, with reference to water temperature
(4 C) and to the elevation above sea level, the
following tables show the drop in hydraulic pressure
head in relation to the elevation above sea level, and
the suction loss in relation to temperature.
Water
temperature (C) 20
Suction
loss (m)

40

0,2 0,7

60 80

90

110

120

2,0 5,0 7,4 15,4 21,5

Elevation above
sea level (m)
500 1000 1500 2000

2500 3000

Suction
loss (m)

2,75

0,55

1,1

1,65

2,2

3,3

Friction loss is shown in the tables at pages 258-259 of


this catalogue. To reduce it to a minimum, especially
in cases of high suction head (over 4-5 m.) or within
the operating limits with high flow rates, we
recommend using a suction line having a larger
diameter than that of the pumps suction port.
It is always a good idea to position the pump as close
as possible to the liquid to be pumped.
Make the following calculation:
Liquid: water at ~15C = 1 kg/dm3
Flow rate required: 25 m3/h
Head for required delivery: 70 m.
Suction lift: 3,5 m.
The selection is an 33SVG075T pump whose NPSH
required value is, at 25 m3/h, di 2 m.
For water at 15 C
hp = Pa / = 10,33m, hpv = Pv / = 0,174m (0,01701 bar)
The Hf flow resistance in the suction line with foot
valves is ~ 1,2 m.
By substituting the parameters in formula 1 with the
numeric values above, we have:
10,33 + (-3,5) (2 + 0,5) + 1,2 + 0,17
from which we have: 6,8 > 3,9
The relation is therefore verified.

256

ps

t
3

bar

kg/dm

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54

273,15
274,15
275,15
276,15
277,15
278,15
279,15
280,15
281,15
282,15
283,15
284,15
285,15
286,15
287,15
288,15
289,15
290,15
291,15
292,15
293,15
294,15
295,15
296,15
297,15
298,15
299,15
300,15
301,15
302,15
303,15
304,15
305,15
306,15
307,15
308,15
309,15
310,15
311,15
312,15
313,15
314,15
315,15
316,15
317,15
318,15
319,15
320,15
321,15
322,15
323,15
324,15
325,15
326,15
327,15

0,00611
0,00657
0,00706
0,00758
0,00813
0,00872
0,00935
0,01001
0,01072
0,01147
0,01227
0,01312
0,01401
0,01497
0,01597
0,01704
0,01817
0,01936
0,02062
0,02196
0,02337
0,24850
0,02642
0,02808
0,02982
0,03166
0,03360
0,03564
0,03778
0,04004
0,04241
0,04491
0,04753
0,05029
0,05318
0,05622
0,05940
0,06274
0,06624
0,06991
0,07375
0,07777
0,08198
0,09639
0,09100
0,09582
0,10086
0,10612
0,11162
0,11736
0,12335
0,12961
0,13613
0,14293
0,15002

0,9998
0,9999
0,9999
0,9999
1,0000
1,0000
1,0000
0,9999
0,9999
0,9998
0,9997
0,9997
0,9996
0,9994
0,9993
0,9992
0,9990
0,9988
0,9987
0,9985
0,9983
0,9981
0,9978
0,9976
0,9974
0,9971
0,9968
0,9966
0,9963
0,9960
0,9957
0,9954
0,9951
0,9947
0,9944
0,9940
0,9937
0,9933
0,9930
0,9927
0,9923
0,9919
0,9915
0,9911
0,9907
0,9902
0,9898
0,9894
0,9889
0,9884
0,9880
0,9876
0,9871
0,9862
0,9862

ps

bar

kg/dm

55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
102
104
106
108
110
112
114
116
118

328,15
329,15
330,15
331,15
332,15
333,15
334,15
335,15
336,15
337,15
338,15
339,15
340,15
341,15
342,15
343,15
344,15
345,15
346,15
347,15
348,15
349,15
350,15
351,15
352,15
353,15
354,15
355,15
356,15
357,15
358,15
359,15
360,15
361,15
362,15
363,15
364,15
365,15
366,15
367,15
368,15
369,15
370,15
371,15
372,15
373,15
375,15
377,15
379,15
381,15
383,15
385,15
387,15
389,15
391,15

0,15741
0,16511
0,17313
0,18147
0,19016
0,1992
0,2086
0,2184
0,2286
0,2391
0,2501
0,2615
0,2733
0,2856
0,2984
0,3116
0,3253
0,3396
0,3543
0,3696
0,3855
0,4019
0,4189
0,4365
0,4547
0,4736
0,4931
0,5133
0,5342
0,5557
0,5780
0,6011
0,6249
0,6495
0,6749
0,7011
0,7281
0,7561
0,7849
0,8146
0,8453
0,8769
0,9094
0,9430
0,9776
1,0133
1,0878
1,1668
1,2504
1,3390
1,4327
1,5316
1,6362
1,7465
1,8628

0,9857
0,9852
0,9846
0,9842
0,9837
0,9832
0,9826
0,9821
0,9816
0,9811
0,9805
0,9799
0,9793
0,9788
0,9782
0,9777
0,9770
0,9765
0,9760
0,9753
0,9748
0,9741
0,9735
0,9729
0,9723
0,9716
0,9710
0,9704
0,9697
0,9691
0,9684
0,9678
0,9671
0,9665
0,9658
0,9652
0,9644
0,9638
0,9630
0,9624
0,9616
0,9610
0,9602
0,9596
0,9586
0,9581
0,9567
0,9552
0,9537
0,9522
0,9507
0,9491
0,9476
0,9460
0,9445

ps

bar

kg/dm3

120
122
124
126
128
130
132
134
136
138
140
145
155
160
165
170
175
180
185
190
195
200
205
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
300
305
310
315
320
325
330
340
350
360
370
374,15

393,15
395,15
397,15
399,15
401,15
403,15
405,15
407,15
409,15
411,15
413,15
418,15
428,15
433,15
438,15
433,15
448,15
453,15
458,15
463,15
468,15
473,15
478,15
483,15
488,15
493,15
498,15
503,15
508,15
513,15
518,15
523,15
528,15
533,15
538,15
543,15
548,15
553,15
558,15
563,15
568,15
573,15
578,15
583,15
588,15
593,15
598,15
603,15
613,15
623,15
633,15
643,15
647,30

1,9854
2,1145
2,2504
2,3933
2,5435
2,7013
2,867
3,041
3,223
3,414
3,614
4,155
5,433
6,181
7,008
7,920
8,924
10,027
11,233
12,551
13,987
15,550
17,243
19,077
21,060
23,198
25,501
27,976
30,632
33,478
36,523
39,776
43,246
46,943
50,877
55,058
59,496
64,202
69,186
74,461
80,037
85,927
92,144
98,70
105,61
112,89
120,56
128,63
146,05
165,35
186,75
210,54
221,20

0,9429
0,9412
0,9396
0,9379
0,9362
0,9346
0,9328
0,9311
0,9294
0,9276
0,9258
0,9214
0,9121
0,9073
0,9024
0,8973
0,8921
0,8869
0,8815
0,8760
0,8704
0,8647
0,8588
0,8528
0,8467
0,8403
0,8339
0,8273
0,8205
0,8136
0,8065
0,7992
0,7916
0,7839
0,7759
0,7678
0,7593
0,7505
0,7415
0,7321
0,7223
0,7122
0,7017
0,6906
0,6791
0,6669
0,6541
0,6404
0,6102
0,5743
0,5275
0,4518
0,3154

G-at_npsh_b_sc

257

TECHNICAL
APPENDIX

TENSIONE DI VAPORE
SURE
PRESSURE
VAPOUR PRES
TABELLA TENSIONE DI VAPORE ps E DENSITA'
DELL'ACQUA
VAPOUR PRES
SURE ps AND DENSITY OF WA
TER T
ABLE
PRESSURE
WATER
TABLE

TABLE OF FL
OW RESIST
ANCE IN 100 m OF STRAIGHT CAST
FLOW
RESISTANCE
IRON PIPELINE (HAZENWILLIAMS FORMULA C=100)
(HAZEN-WILLIAMS

TECHNICAL
APPENDIX

FLOW RATE
m3/h l/min
0,6

10

0,9

15

1,2

20

1,5

25

1,8

30

2,1

35

2,4

40

50

3,6

60

4,2

70

4,8

80

5,4

90

100

7,5

125

150

10,5

175

12

200

15

250

18

300

24

400

30

500

36

600

42

700

48

800

54

900

60

1000

75

1250

90

1500

105

1750

120

2000

150

2500

180

3000

210

3500

240

4000

300

5000

360

6000

420

7000

480

8000

540

9000

600

10000

v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr
v
hr

15
1/2"

20
3/4"

25
1"

32
1 1/4"

40
1 1/2"

0,94
16
1,42
33,9
1,89
57,7
2,36
87,2
2,83
122
3,30
162

0,53
3,94
0,80
8,35
1,06
14,21
1,33
21,5
1,59
30,1
1,86
40,0
2,12
51,2
2,65
77,4
3,18
108
3,72
144
4,25
185

0,34
1,33
0,51
2,82
0,68
4,79
0,85
7,24
1,02
10,1
1,19
13,5
1,36
17,3
1,70
26,1
2,04
36,6
2,38
48,7
2,72
62,3
3,06
77,5
3,40
94,1
4,25
142

0,21
0,40
0,31
0,85
0,41
1,44
0,52
2,18
0,62
3,05
0,73
4,06
0,83
5,19
1,04
7,85
1,24
11,0
1,45
14,6
1,66
18,7
1,87
23,3
2,07
28,3
2,59
42,8
3,11
59,9
3,63
79,7
4,15
102
5,18
154

0,13
0,13
0,20
0,29
0,27
0,49
0,33
0,73
0,40
1,03
0,46
1,37
0,53
1,75
0,66
2,65
0,80
3,71
0,93
4,93
1,06
6,32
1,19
7,85
1,33
9,54
1,66
14,4
1,99
20,2
2,32
26,9
2,65
34,4
3,32
52,0
3,98
72,8
5,31
124
6,63
187

50
2

0,17
0,16
0,21
0,25
0,25
0,35
0,30
0,46
0,34
0,59
0,42
0,89
0,51
1,25
0,59
1,66
0,68
2,13
0,76
2,65
0,85
3,22
1,06
4,86
1,27
6,82
1,49
9,07
1,70
11,6
2,12
17,5
2,55
24,6
3,40
41,8
4,25
63,2
5,10
88,6
5,94
118
6,79
151
7,64
188

NOMINAL DIAMETER in mm and inches


65
80
100
125 150
175
2 1/2"
3"
4"
5"
6"
7"

200
8"

250
10"

300
12"

350
14"

400
16"

0,53
0,27
0,66
0,40
0,80
0,56
0,93
0,75
1,06
0,96
1,33
1,45
1,59
2,03
1,86
2,71
2,12
3,46
2,65
5,23
3,18
7,33
3,72
9,75
4,25
12,49
4,78
15,5
5,31
18,9

0,68
0,32
0,85
0,49
1,02
0,69
1,19
0,91
1,36
1,17
1,70
1,77
2,04
2,47
2,38
3,29
2,72
4,21
3,06
5,24
3,40
6,36

0,71
0,28
0,83
0,38
0,94
0,48
1,18
0,73
1,42
1,02
1,65
1,35
1,89
1,73
2,12
2,16
2,36
2,62

1,21
0,64
1,39
0,82
1,56
1,02
1,73
1,24

1,19
0,53
1,33
0,65

The hr values must be multiplied by:


0,71 for galvanized or painted steel pipes
0,54 for stainless steel or copper pipes
0,47 for PVC or PE pipes

0,20
0,16
0,25
0,25
0,30
0,35
0,35
0,46
0,40
0,59
0,45
0,74
0,50
0,90
0,63
1,36
0,75
1,90
0,88
2,53
1,01
3,23
1,26
4,89
1,51
6,85
2,01
11,66
2,51
17,6
3,02
24,7
3,52
32,8
4,02
42,0
4,52
52,3
5,03
63,5
6,28
96,0
7,54
134
8,79
179

0,30
0,27
0,33
0,33
0,41
0,49
0,50
0,69
0,58
0,92
0,66
1,18
0,83
1,78
1,00
2,49
1,33
4,24
1,66
6,41
1,99
8,98
2,32
11,9
2,65
15,3
2,99
19,0
3,32
23,1
4,15
34,9
4,98
48,9
5,81
65,1
6,63
83,3
8,29
126

0,32
0,23
0,37
0,31
0,42
0,40
0,53
0,60
0,64
0,84
0,85
1,43
1,06
2,16
1,27
3,03
1,49
4,03
1,70
5,16
1,91
6,41
2,12
7,79
2,65
11,8
3,18
16,5
3,72
21,9
4,25
28,1
5,31
42,5
6,37
59,5
7,43
79,1
8,49
101

0,34
0,20
0,41
0,28
0,54
0,48
0,68
0,73
0,82
1,02
0,95
1,36
1,09
1,74
1,22
2,16
1,36
2,63
1,70
3,97
2,04
5,57
2,38
7,40
2,72
9,48
3,40
14,3
4,08
20,1
4,76
26,7
5,44
34,2
6,79
51,6
8,15
72,3

0,38
0,20
0,47
0,30
0,57
0,42
0,66
0,56
0,75
0,72
0,85
0,89
0,94
1,08
1,18
1,63
1,42
2,29
1,65
3,05
1,89
3,90
2,36
5,89
2,83
8,26
3,30
11,0
3,77
14,1
4,72
21,2
5,66
29,8
6,61
39,6
7,55
50,7
8,49
63,0

0,42
0,20
0,49
0,26
0,55
0,34
0,62
0,42
0,69
0,51
0,87
0,77
1,04
1,08
1,21
1,44
1,39
1,84
1,73
2,78
2,08
3,90
2,43
5,18
2,77
6,64
3,47
10,0
4,16
14,1
4,85
18,7
5,55
23,9
6,24
29,8
6,93
36,2

G-at-pct-en_a_th

hr = flow resistance for 100 m of straight pipeline (m)


V = water speed (m/s)

258

FL
OW RESIST
ANCE
FLOW
RESISTANCE
TABLE OF FL
OW RESIST
ANCE IN BENDS, V
AL
VES AND
FLOW
RESISTANCE
VAL
ALVES
GA
TES
GATES
The flow resistance is calculated using the equivalent pipeline length method according to the table below:

TABELLA LUNGHEZZA DI TUBAZIONE EQUIVALENTE


DN

ACCESSORY
TYPE

45 bend
90 bend
90 smooth bend
Union tee or cross
Gate
Non return valve

25

32

40

50

0,2
0,4
0,4
1,1
1,1

0,2
0,6
0,4
1,3
1,5

0,4
0,9
0,4
1,7
1,9

0,4
1,1
0,6
2,1
0,2
2,4

65
80
100
125
Equivalent pipeline length (m)
0,6
0,6
0,9
1,1
1,3
1,5
2,1
2,6
0,9
1,1
1,3
1,7
2,6
3,2
4,3
5,3
0,2
0,2
0,4
0,4
3,0
3,4
4,7
5,9

150

200

250

300

1,5
3,0
1,9
6,4
0,6
7,4

1,9
3,9
2,8
7,5
0,9
9,6

2,4
4,7
3,4
10,7
1,1
11,8

2,8
5,8
3,9
12,8
1,3
13,9

G-a-pcv-en_a_th

TECHNICAL
APPENDIX

The table is valid for the Hazen Williams coefficient C=100 (cast iron pipework);
for steel pipework, multiply the values by 1,41;
for stainless steel, copper and coated cast iron pipework, multiply the values by 1,85;
When the equivalent pipeline length has been determined, the flow resistance is obtained from the table of
flow resistance.
The values given are guideline values which are bound to vary slightly according to the model, especially for gate
valves and non-return valves, for which it is a good idea to check the values supplied by manufacturers.

259

V
OL
UMETRIC
CAP
ACITY
OLUMETRIC
CAPACITY
VOLUMETRIC
CAPACITY
Litres

Cubic metres

Cubic feet

Cubic feet

Imp. gal.

US gal.

per minute

per hour

per hour

per minute

per minute

per minute

l/min

m3/h

ft3/h
0,0600
1,0000
0,0283
1,6990
0,2728
0,2271

1,0000
16,6667
0,4719
28,3168
4,5461
3,7854

ft3/min
0,0353
0,5886
0,0167
1,0000
0,1605
0,1337

Imp. gal/min
0,2200
3,6662
0,1038
6,2288
1,0000
0,8327

Us gal./min
0,2642
4,4029
0,1247
7,4805
1,2009
1,0000

Pound force per


square inch
psi
1.45 x 10-4
0,1450
14,5038
1,0000
1,4223
0,0193

metre
of water
m H 2O
1.02 x 10-4
0,1020
10,1972
0,7031
1,0000
0,0136

millimetre of
mercury
mm Hg
0,0075
7,5006
750,0638
51,7151
73,5561
1,0000

2,1189
35,3147
1,0000
60,0000
9,6326
8,0208

PRESSURE
AND
HEAD
SURE
AND
HEAD
PRESSURE
PRES
Newton per
square metre
N/m2
1,0000
1000,0000
1 x 105
6894,7570
9806,6500
133,3220

kilo Pascal

bar

kPa

bar
1 x 10-5
0,0100
1,0000
0,0689
0,0981
0,0013

0,0010
1,0000
100,0000
6,8948
9,8067
0,1333

LENGTH
TH
LENGTH
LENG
millimetre

centimetre

metre

inch

foot

yard

mm

cm

in

ft

yd

1,0000
10,0000
1000,0000
25,4000
304,8000
914,4000

0,1000
1,0000
100,0000
2,5400
30,4800
91,4400

0,0010
0,0100
1,0000
0,0254
0,3048
0,9144

0,0394
0,3937
39,3701
1,0000
12,0000
36,0000

0,0011

0,0033
0,0328
3,2808
0,0833
1,0000
3,0000

0,0109
1,0936
0,0278
0,3333
1,0000

VOLUME
OL
UME
OLUME
V
cubic metre

TECHNICAL
APPENDIX

1,0000
0,0010
1 x 10-6
0,0045
0,0038
0,0283

litre

millilitre

imp. Gallon

US gallon

cubic foot

litro

ml

imp. gal.

US gal.

ft3

1000,0000
1,0000
0,0010
4,5461
3,7854
28,3168

1 x 106
1000,0000
1,0000
4546,0870
3785,4120
28316,8466

219,9694
0,2200
2.2 x 10-4
1,0000
0,8327
6,2288

264,1720
0,2642
2.642 x 10-4
1,2009
1,0000
7,4805

35,3147
0,0353
3.53 x 10-5
0,1605
0,1337
1,0000
G-at_pp-en_a_sc

260

FURTHER PRODUCT SELECTION AND DOCUMENT


ATION
DOCUMENTA
Xylect

Xylect is pump solution selection software with an extensive online database of product information across the entire
Lowara, and Vogel range of pumps and related products, with multiple search options and helpful project management
facilities. The system holds up-to-date product information on thousands of products and accessories.
The possibility to search by applications and the detailed information output given makes it easy to make the optimal
selection without having detailed knowledge about the Lowara and Vogel products.

The search can be made by:

Application

Product type

Duty point

List with search results

Performance curves (flow, head, power,


efficiency, NPSH)

Motor data

Dimensional drawings

Options

Data sheet printouts

Document downloads incl dxf files

The search by application guides users not familiar with


the product range to the right choice.

261

TECHNICAL
APPENDIX

Xylect gives a detailed output:

FURTHER PRODUCT SELECTION AND DOCUMENT


ATION
DOCUMENTA
Xylect

The detailed output makes it easy to select the optimal pump from the given alternatives.

TECHNICAL
APPENDIX

The best way to work with Xylect is to create a


personal account. This makes it possible to:

Set own standard units

Create and save projects

Share projects with other Xylect users

Every user have a My Xylect space, where all projects


are saved.
For more information about Xylect please contact
our sales network or visit www.xylect.com.

Dimensional drawings appear on the screen and can be


downloaded in dxf format.

262

Xylem
1) The tissue in plants that brings water upward from the roots;
2) a leading global water technology company.
Were 12,000 people unied in a common purpose: creating innovative solutions
to meet our worlds water needs. Developing new technologies that will improve
the way water is used, conserved, and re-used in the future is central to our work.
We move, treat, analyze, and return water to the environment, and we help people
use water efciently, in their homes, buildings, factories and farms. In more than 150
countries, we have strong, long-standing relationships with customers who know us
for our powerful combination of leading product brands and applications expertise,
backed by a legacy of innovation.
For more information on how Xylem can help you, go to xyleminc.com.

Headquarters
LOWARA S.r.l. Unipersonale
Via Vittorio Lombardi 14
36075 Montecchio Maggiore - Vicenza - Italy
Tel.(+39) 0444 707111 - Fax(+39) 0444 492166
e-mail: lowara.mkt@xyleminc.com
web: www.lowara.com - www.completewatersystems.com
LOWARA reserves the right to make modication without prior notice.
2013 Xylem, Inc.