Full Body Immersion Tanks

Use

F Series
270 Gallon
Stationary Full
Body Immersion Tank
(Hubbard Tank) F-270-S

Product photo/image above may show some available options

Whitehall Model F-270-S Full Body Immersion and lifetime-sealed bearings. All parts contacting
Tank is recommended for treatment of upper and the water are stainless steel, chrome plated brass
lower extremities permitting patients full body or bronze.
immersion, room for body motion and exercise. Thermometer is provided with a dual scale,
This Hubbard style tank with figure “8” configura- adjustable calibration, and a stem inserts into a
tion allows therapists easy access to assure patient retainer to prevent rattle during whirlpool agita-
comfort. tion.
Tank Capacity is 270 gallons. GUIDE SPECIFICATIONS
Hubbard Tank figure “8” configuration is overall Provide Whitehall Stationary Full Body Immersion
93”L x 64”W x 22”D and is seamless welded con- Tank with figure “8” configuration (specify model
struction, fabricated from heavy gauge, type 304 number and options) with a 270-gallon capacity,
stainless steel, polished to a satin finish. Tank bottom 93”L x 64”W x 22”D. Hubbard tank shall be
is a rounded covered design to minimize bacteria fabricated from heavy gauge, type 304 stainless steel.
buildup. Tank has a reinforced stainless steel base Construction shall be seamless welded and exposed
supported by adjustable stainless steel legs. Tank fit- surfaces shall be polished to satin finish. Tank bottom
tings are two1-1/4” OD overflows, one 1-1/4” NPT shall be a seamless rounded coved design to mini-
filler spout, one lever operated quick open/close mize bacteria buildup and shall be reinforced with a
drain valve and an adjustable head rest. stainless steel base supported by stainless steel legs
Turbine Raising and Lowering Device permits which are adjustable. Provide twin turbine assem-
adjustment of desired height and direction of blies mounted on carriages with automatic counter-
water agitation towards the area of the body to be balance. Each turbine assembly with raising and
treated. It is spring balanced and provided with a lowering device shall permit adjustment of desired
locking device. height, direction of water agitation, and lock-
Twin Turbine Assemblies are mounted on car- ing in place.Turbine assemblies shall have UL
riages with automatic counter balance. Assemblies listed 1/2 HP jet pump motor with automatic
may be moved along the tank length for the most thermal overload protector, and lifetime-sealed
advantageous treatment position. Each assembly is bearings. Provide a thermometer with a stem retain-
equipped with Underwriters Laboratory listed 1/2 er to prevent rattle when whirlpool is in operation.
HP jet pump motor protected with an ABS plastic An adjustable head rest assembly is also provided.
shell, and automatic thermal overload protector,

Whitehall Mfg. > P.O. Box 3527 > City of Industry, CA 91744 > (800) 782-7706 > (626) 968-6681 > FAX (626) 855-4862

Last Update: 2/14/08


F-270-S
Full Body Immersion Tanks
MODEL NUMBER AND OPTION SELECTIONS
Series m -MXT3 Thermostatic Mixing Valve (45 G.P.M.)
m -F Full Body Immersion Tank m -MXT4 Thermostatic Mixing Valve (80 G.P.M.)
Capacity m -MXT5 Thermostatic Mixing Valve (125 G.P.M.)
m -270 Gallons m -MXWH Washout Hose Attachment
Type m -OEH1 Overhead Electric Hoist (115V 60Hz)
m -S Stationary m -OEH2 Overhead Electric Hoist (220V 50Hz)
m -OEH3 Overhead Electric Hoist (220V 60Hz)
Suffix Options (See Whirlpool Option Section for Details) m -PCS Pump Cover Strainer
m -AEH Attachment for Electric Hoist m -PHS1 Patient Handling System (Stretcher Type)
m -AMF Adjustable Mounting Fixture m -PHS2 Patient Handling System (Chair Type)
m -BH Body Hammock m -RC Recessed Stainless Steel Cabinet
m -BHS Body Hoist Sling m -WMB Wall Mounting Brackets
m -BSS Body Support Stretcher
m -ECR Electric Cord Reel with 25’ Cord Turbine Assembly
Electrical on standard turbine supplied is 115 V 60 Hz
m -GFI Ground Fault Interrupter if 220 V is required please specify:
m 50 Hz m 60 Hz

Note: Electrical requirements are 8 Amps / 115 Volts/ 60Hz/ 3 Pole GFI Receptacle.

All dimension figures


in parentheses are
in millimeters.

All dimensions are nominal and subject to manufac- SELECTION SUMMARY & APPROVAL FOR MANUFACTURING


turer’s change without notice. Whitehall assumes no
Model Number & Options_____________________________________________ Quantity_____________
responsibility for use of void or suspended data. © 2008
Whitehall Manufacturing, A Division of Acorn Engineering Company_________________________________________________________ Date___________________
Company. Please visit www.whitehallmfg.com for most Contact________________________________________________ Title______________________________
current specifications. Approval for Manufacturing/Signature_______________________________________________________

Whitehall Mfg. > P.O. Box 3527 > City of Industry, CA 91744 > (800) 782-7706 > (626) 968-6681 > FAX (626) 855-4862

Last Update: 2/14/08