Sie sind auf Seite 1von 163

Standard Sensors & Accessories

for EMAT Applications


Rev. T-SA-E10














InnerspecTechnologies
www.innerspec.com
4004 Murray Place
Lynchburg, VA 24501, USA
Tel: +1-434.948.1301
Fax: +1-434.948.1313
2010 Innerspec Technologies, Inc.
All Rights Reserved

This Material May Not Be Published, Rewritten,
or Redistributed Without Express Permission



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 2 of 163 InnerspecTechnologies
Table of Contents

1. Introduction to Electro Magnetic Acoustic Transducer (EMAT).................................................................. 3
1.1. Wave Modes ....................................................................................................................................... 4
2. Applications ................................................................................................................................................ 5
2.1. Normal (zero degree) Beam................................................................................................................ 5
3. Angled Beam and Phased Array ................................................................................................................ 6
4. Guided Waves ............................................................................................................................................ 7
5. Equipment Configuration ............................................................................................................................ 8
6. Instrumentation ........................................................................................................................................... 9
7. Standard Sensors & Accessories ............................................................................................................... 9
7.1. Complete Sensors with Built-In RF Coil ............................................................................................ 10
7.1.1. High-Temperature Normal Beam Sensors (>100C) ................................................................. 10
7.1.1.1. High Temperature Sensor SH Butterfly (450C Air Cooled) ................................................ 11
7.1.1.2. High Temperature Sensor SH Spiral (450C Air Cooled) .................................................... 12
7.1.1.3. High Temperature Sensor SH Spiral w/o Active Cooling 1 (Spot Measurement) .............. 13
7.1.1.4. High Temperature Sensor SH Spiral w/o Active Cooling 1.50 (Spot
Measurement) ...................................................................................................................... 14
7.1.1.5. High Temperature L Wave Sensor (only for non-ferromagnetic materials) ......................... 15
7.1.1.6. Ultra-High Temperature L Wave Sensor.............................................................................. 16
7.1.2. Phased Array Sensors ................................................................................................................ 17
7.1.2.1. Phased Array 8-Channel SH (Pitch-Catch) ......................................................................... 18
7.1.2.2. Phased Array 8-Channel SH (Pitch-Catch) Tandem Sensor ............................................... 19
7.2. Sensors with Detachable RF Coil ..................................................................................................... 20
7.2.1. Permanent Magnet Probes ......................................................................................................... 20
7.2.2. Pulsed Magnet Probes ............................................................................................................... 21
7.2.3. Detachable RF Coils ................................................................................................................... 22
7.2.3.1. Normal (zero degree) RF Coils Tables ................................................................................ 23
7.2.3.2. Phased Array RF Coils ........................................................................................................ 31
7.2.3.3. Angled Beam and Guided Wave RF Coils ........................................................................... 36
7.2.3.4. Guided Wave Setup Process ............................................................................................... 38
7.2.3.5. RF Coils for Angled Beam and Guided Waves (Lamb and Rayleigh) with
Permanent Magnet Probes (Summary Tables) ................................................................... 42
7.2.3.6. RF Coils for Angled Beam and Guided Waves (Lamb, Rayleigh and SH) with
Small Pulsed Magnet Probes (Summary Tables) ................................................................ 76
7.2.3.7. RF Coils for Angled Beam and Guided Waves (Lamb and SH) with Medium
Pulsed Magnet Probes (Summary Tables) ........................................................................ 125
8. Signal Conditioning Box (Remote Box) .................................................................................................. 157
9. Interconnecting Cables & Adapters ........................................................................................................ 158
10. Accessories ............................................................................................................................................ 159
10.1. Wear Surfaces ................................................................................................................................ 159
10.1.1. Metallic ...................................................................................................................................... 159
10.1.2. Non-Metallic .............................................................................................................................. 159
10.2. Compliance Spring Foam................................................................................................................ 160
10.3. RF Coil Fasteners ........................................................................................................................... 160
10.4. Sensor & Probe Fixtures ................................................................................................................. 161
10.5. Encoders and Thermocouples ........................................................................................................ 162
10.6. Transport Cases .............................................................................................................................. 162
11. Limited Warranty ..................................................................................................................................... 163





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 3 of 163 InnerspecTechnologies
1. Introduction to Electro Magnetic Acoustic Transducer (EMAT)

EMAT or Electro Magnetic Acoustic Transducer is an Ultrasonic Testing (UT) technique that generates the
sound in the part inspected instead of the transducer.

An EMAT induces ultrasonic waves into a test object with two interacting magnetic fields. A relatively high
frequency (RF) field generated by electrical coils interacts with a low frequency or static field generated by
magnets to generate a Lorentz force in a manner similar to an electric motor. This disturbance is
transferred to the lattice of the material, producing an elastic wave. In a reciprocal process, the interaction
of elastic waves in the presence of a magnetic field induces currents in the receiving EMAT coil circuit. For
ferromagnetic conductors, magnetostriction produces additional stresses that enhance the signals to much
higher levels than could be obtained by the Lorentz force alone. Various types of waves can be generated
using different combinations of RF Coils and Magnets.





Because the sound is generated in the part inspected instead of the transducer, EMATs have the following
advantages over more conventional piezoelectric transducers:

- Dry inspection. EMATs do not require couplant for transmitting sound, which makes them very well
suited for inspection of hot parts, and integration in automated environments.
- Impervious to surface conditions. EMATs can inspect through coatings and are not affected by
pollutants, oxidation or roughness.
- Easier probe deployment. Not having wedges or couplant, Snells law of refraction does not apply,
and the angle of the probe does not affect the direction of propagation. This makes them easier to
control and deploy, especially in automated environments.
- Ability to generate unique wave modes. EMATs are the only practical means for generating shear
waves with horizontal polarization (SH waves), which do not travel through low-density couplants.
The ability to easily produce Guided SH waves and lamb waves make EMAT ideal for generation of
guided waves, used in the inspection of plates, tubes and rounds.
Piezoelectric UT EMAT UT

EMAT Coil
Circuit
Ultrasonic Wave Ultrasonic Wave
Eddy Currents
Lorentz
Force
Magnetic Field


Couplant

Crystal


Magnet



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 4 of 163 InnerspecTechnologies
1.1. Wave Modes

EMAT is capable of generating all wave modes used in ultrasonic testing, including some modes that are
very difficult or impractical with conventional piezoelectric transducers.

The table below provides a summary guide of the type of wave and technique available for different
applications.

Bulk/Guided
Beam
Orientation
Wave
Mode
Technique
Main
Applications
Bulk

Normal
Longitudinal
Piezo
EMAT
- Thickness and Velocity
Measurements
- Flaw Detection
- Properties Measurement
Shear
Horizontal
EMAT
1

Angled
Shear
Vertical
Piezo
EMAT
- Flaw Detection
Shear
Horizontal
EMAT
1

- Flaw Detection,
including austenitic
materials
Guided
Surface Rayleigh
Piezo
EMAT
2

- Flaw Detection (surface)
Volumetric
Lamb
Piezo
EMAT
2

- Flaw (including
Corrosion) Detection
- Velocity and Properties
Measurements
Shear
Horizontal
EMAT
1

- Flaw (including
Corrosion) Detection
- Velocity and Properties
Measurements

1
Generation restricted to EMAT for practical purposes
2
Especially well suited for generation with EMAT


The applications covered in this Catalog include:

- Bulk, Normal Beam (zero degree incident angle) with Shear Horizontal and Longitudinal Waves.
- Bulk, Angled Beam Single Channel and Phased Array
- Guided Wave, Surface and Volumetric







Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 5 of 163 InnerspecTechnologies
2. Applications

2.1. Normal (zero degree) Beam

Characteristics
- Direction of Propagation: Perpendicular to the entry wall.
- Sensor Configuration: Pulse-echo (transmitter = receiver) or pitch-
catch (transmitter receiver)
- Wave modes: Shear Horizontal and Longitudinal waves in
frequencies ranging from 500 KHz to 10MHz. Whereas EMAT can
generate both Shear and Longitudinal waves at 0 degrees, Shear
(Horizontal) waves are easier to generate.
- Materials Inspected: Ferromagnetic and non-ferromagnetic metals.

Applications
- Thickness measurement.
- Corrosion and erosion measurement.
- Flaw detection, such as, inclusions, de-laminations and disbond.
- Acoustic velocity measurement.
- Rolling direction recognition.
- Anisotropy and stress measurement.
- Nodularity measurement.
- Bolt-Load measurement.
- Spot-Weld inspection.

EMAT Uniqueness
- Dry and non-contact. Practical working distance from the coil to the part (lift-off) is usually between
0-3mm. Greater lift-off can be achieved (up to 12mm in laboratory settings), depending on material,
equipment and type of inspection. Ideal for automated and hot environments.
- Not affected by surface conditions (coatings, oil, oxide).
- Maintains readings even when the probe face is not parallel to the part. The only restriction in
coil/sensor angle is that derived from the loss of signal due to lift-off, so depending on the
application the coil/sensor can be angled as much as 30 from the part and still obtain good signals.
- Capable of generating Shear wave energy (Shear Horizontal). Shear waves have approximately
half the velocity of Longitudinal waves providing better time resolution (especially important for
defects next to walls). Shear waves are also is capable of detecting defects perfectly perpendicular
to the direction of sound.
- Ability to select the direction of polarization when using Racetrack or Butterfly style coils (see RF
Coil section).
- Because EMAT by definition cannot use a delay line (or water column), there is a dead zone of
approximately 4s (equivalent to around 6mm of material). This dead zone can be circumvented
when parallel walls are present by relying on the 2
nd
bounce from the wall to perform the inspection.














Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 6 of 163 InnerspecTechnologies
3. Angled Beam and Phased Array

Characteristics
- Direction of Propagation: At an angle from the entry wall.
- Sensor Configuration: Pulse-echo or pitch-catch, including Phased
Array
- Wave modes: Shear Horizontal and Shear Vertical at angles from
10 to 80 in frequencies ranging from 500KHz to 10MHz.
- Materials Inspected: Ferromagnetic and non-ferromagnetic metals.

Applications
- Flaw detection, including weld inspection.
- Austenitic weld inspection in heavy walls (>0.5 - 13mm) using SH
waves.
- Corrosion and erosion measurement.
- Detection of hydrogen damage and pitting.

EMAT Uniqueness
- Dry and non-contact (up to 2.5mm lift-off depending on application
and frequency). Ideal for automated and hot environments.
- Not affected by surface conditions (coatings, oil, oxide). Capable of
inspecting on severely pitted surfaces.
- While Angled Beam Shear Vertical energy is easy to generate using
refracting angles on piezoelectric transducers (PZT), Shear
Horizontal Angled Beams do not travel through low-density
couplants, so they are difficult to generate and excluded from
applications that require any scanning.
- The polarity of the energy (vertical Vs horizontal) is important since
shear waves do not mode convert when striking surfaces that are
parallel to the direction of polarization thus Shear Horizontal waves
are especially well suited for inspection of austenitic welds and other
materials with dendritic grain structures.
- Inspection at temperatures of up to 400F (200C).





















Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 7 of 163 InnerspecTechnologies
4. Guided Waves

Characteristics
- Direction of Propagation: Parallel to the entry wall and within the
boundaries of the top and bottom walls. Limited to approximately
0.5 (12mm) plate thickness for internal flaw detection.
- Sensor Configuration: Pulse-echo or pitch-catch.
- Wave modes: Shear Horizontal at 90, Lamb waves and Rayleigh
waves in frequencies ranging from 50KHz to 10MHz.
- Materials Inspected: Ferromagnetic and non-ferromagnetic metals.

Applications
- Weld inspection in thin plates (<0.5 or 13mm).
- Inspection of welds while welding. For example, inspection of the different layers on submerged
arc welds before all the layers have been deposited.
- Flaw detection in plates, tubes and rods.
- Corrosion and erosion measurement.
- Material properties characterization (e.g. acoustic velocity measurement).

EMAT Uniqueness
- Dry and non-contact (up to 2.5mm lift-off depending on frequency and type of application). Ideal for
automated environments.
- Not affected by surface conditions (coatings, oil, oxide).
- Ability to normalize the signal for automatic and continuous self-calibration.
- Less sensitive to probe positioning. Especially well-suited for automated weld inspection.
- Ability to concentrate the energy on the outside boundaries or center of the material to be more or
less sensitive to surface or internal defects (e.g. to avoid or ignore root and crown in weld
inspection).






Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 8 of 163 InnerspecTechnologies
5. Equipment Configuration

The picture below shows a common configuration for EMAT equipment.




1. Instrumentation & Computer. The temate

PowerBox 1, 2 and 8 require an external computer.


2. Instrument to Signal Conditioning Box Cables. Connect the instrument to the Signal Conditioning
Box, and can be up to 150 (50m) in length.
3. Signal Conditioning Box. Provides RF coil and cable impedance matching, T/R switching and a first
stage of amplification. In some applications, Tuning Modules are also used to match the RF Coil at
a specific frequency. The Signal Conditioning Box is normally located 2-4 (60-120cm) from the
sensors.
4. Sensor Cables. Connect the probe and RF Coil to the Signal Conditioning Box and can be up to 4
(120cm) in length.
5. Probe*. Housing containing the magnet (permanent or electromagnet) and the hardware for
attaching the RF Coils (when detachable). Many probes manufactured by Innerspec Technologies
can incorporate various types of RF coils for different applications, whereas others have built-in RF
coils that cannot be easily exchanged.
6. Coils & Wear Surface. Detachable RF Coils and wear surfaces are listed as separate items in this
catalog.

- The combination of Probe + RF Coil is referred to as a Sensor in this catalog.
2
3
4
5
6
1



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 9 of 163 InnerspecTechnologies
6. Instrumentation

Please refer to Instrumentation for High-Power Ultrasonic Applications catalog for details.

7. Standard Sensors & Accessories

The Standard Sensors included in this catalog in conjunction with temate

PowerBox instruments or
similar are designed to cover a great variety of EMAT inspections. Innerspec Technologies also offers
Application Specific instrumentation and sensors and custom designs. Contact Innerspec Technologies for
additional information on Sensors and Applications not covered in this Catalog.

The Standard Sensors are divided in two groups:

- Complete Sensors with attached RF Coil. Used on Phased Array and High-Temperature Normal Beam
applications.
- Sensor with detachable RF Coil (separate Probe and RF Coil). Used on ambient temperature Normal
Beam, Bulk Angled and all Guided Wave applications.

The Sensors in this Catalog are designed using floating-ground technology that provides optimum
performance and immunity to noise. These sensors require three pole connectors, and will not work with
standard coaxial cables. On the same token, the standard signal conditioning boxes will not work with non-
differential sensors built by other manufacturers. For best results, it is recommended to use sensors,
cables and signal conditioning boxes as a set from Innerspec Technologies. Contact Innerspec if you need
a custom sensor not available in this Catalog.





Permanent Magnet Probes Can Create Very Powerful Magnetic Fields
Handle With Care

















Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 10 of 163 InnerspecTechnologies
7.1. Complete Sensors with Built-In RF Coil

7.1.1. High-Temperature Normal Beam Sensors (>100C)

Part
Number
Wave
Mode
EMAT
Type
Magnet
Type
Maximum
Temperature
and Time
w/o Active
Cooling
Maximum
Temperature
and Time
with Active
Cooling (Air)
Connector Dim.
Applications,
Range and
Accuracy
3

274A0125
1

SH
Butterfly
Lorentz Permanent
<130C
Unlimited

150-450C
Unlimited

450C-650C
30s
2-Pin
Lemo 0B
2.5 D x
2.75 H

(64mm x
70mm)
Thickness Gage
Flaw Detection

Range
1-100mm
Acc. 0.0125mm
274A0126
SH
Spiral
Lorentz Permanent
<130C
Unlimited

150-450C
Unlimited

450C-650C
30s
2-Pin
Lemo 0B
2.5 D x
2.75 H

(64mm x
70mm)
Thickness Gage
Flaw Detection

Range
1-100mm
Acc.
0.0125mm
274A0145
SH
Spiral
Lorentz Permanent
<200C
Unlimited

650C
5s
2-Pin
Lemo 0B
1.00 D x
2.25 H

(25mm x
57mm)
Thickness Gage
Flaw Detection

Range
1-50mm
Acc.
0.0125mm
274A0146
SH
Spiral
Lorentz Permanent
<200C
Unlimited

650C
5s
2-Pin
Lemo 0B
1.50 D x
3.00 H

(38mm x
76mm)
Thickness Gage
Flaw Detection

Range
1-100mm
Acc.
0.0125mm
274A0128
2

L
Linearly
Polarized
Lorentz Permanent
<130C
Unlimited
150-450C
Unlimited

450C-650C
30s
2-Pin
Lemo 0B
2.25 H
3.75 W
3.25 L

57mm H
95mm W
83mm L
Thickness Gage

Range
1-500mm
Acc.
0.0125mm
274A0143
2

L
Linearly
Polarized
Lorentz Permanent
<130C
Unlimited
1000C
Unlimited
2-Pin
Lemo 0B
2.50 H
3.25 W
3.50 L

64mm
83mm
89mm L
Thickness Gage

Range
1-100mm
Acc.
0.0125mm

1. Sensor 274A0125 has a linearly polarized coil for maximum accuracy on thin, and anisotropic materials. Different readings are
obtained depending on the orientation of the sensor and the rolling direction (also valid for measuring anisotropy).
2. L-Wave Sensors 274A0128 and 274A0143 are only valid for non-ferromagnetic materials (or ferromagnetic above Curie point).
All SH probes are valid for magnetic or non-magnetic materials.
3. Typical values for aluminum, carbon steel and other conductive materials. Two back walls or more are required for maximum
accuracy.





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 11 of 163 InnerspecTechnologies
7.1.1.1. High Temperature Sensor SH Butterfly (450C Air Cooled)

Part Number 274A0125

Sensor Type SH Lorentz Permanent Magnet
Temperature Ranges
130C Continuous w/o Air
130C-450C Continuous with Air (2Bar)
450C-650C 30s with Air
Connector 2 Pin Lemo 0B
RF Coil Geometry Butterfly
Coil
Width
inch 0.726
mm 18.15
Coil
Length
inch 0.492
mm 12.30
Sensor
Dimensions
inch 2.5 D x 2.75 H
mm 64mm D x 70mm H
Air Coupling
NPT
M14 x 1.5 male adapter provided
Anchor Points
4 - #8-32 threaded holes located 90 on
a 2 dia. Circle

Frequency Spectra & 3dB Beam Profiles

0 2000 4000 6000 8000 10000
2
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
R
e
s
p
o
n
s
e

(
m
V
)



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 12 of 163 InnerspecTechnologies
7.1.1.2. High Temperature Sensor SH Spiral (450C Air Cooled)

Part Number 274A0126

Sensor Type SH Lorentz Permanent Magnet
Temperature Ranges
130C Continuous w/o Air
130C-450C Continuous with Air (2Bar)
450C-650C 30s with Air
Connector 2 Pin Lemo 0B
Coil Geometry Spiral
Coil
OD
inch 0.730
mm 18.25
Coil
ID
inch 0.250
mm 6.25
Sensor
inch 2.5 D x 2.75 H
mm 64mm D x 70mm H
Air Coupling
NPT
M14 x 1.5 male adapter provided
Anchor Points 4 - #8-32 threaded holes

Frequency Spectra & 3dB Beam Profiles



0 2000 4000 6000 8000 10000
2
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
R
e
s
p
o
n
s
e

(
m
V
)



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 13 of 163 InnerspecTechnologies
7.1.1.3. High Temperature Sensor SH Spiral w/o Active Cooling 1 (Spot Measurement)

Part Number 274A0145

Sensor Type SH Lorentz Permanent Magnet
Temperature Ranges
200C Continuous w/o Air
650C 5s
Cable & Connector 1.5m Cable with 2 Pin Lemo 0B
Coil Geometry Spiral
Coil
OD
inch 0.438
mm 11.1
Coil
ID
inch 0.125"
mm 3.2mm
Sensor
inch 1 D x 2.25 H
mm 25mm D x 57mm H
Handle 300mm Long
Anchor Point Threaded Connection

Frequency Spectra & 3dB Beam Profiles



0 2000 4000 6000 8000 10000
2
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
R
e
s
p
o
n
s
e

(
m
V
)



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 14 of 163 InnerspecTechnologies
7.1.1.4. High Temperature Sensor SH Spiral w/o Active Cooling 1.50 (Spot Measurement)

Part Number 274A0146

Sensor Type SH Lorentz Permanent Magnet
Temperature Ranges
200C Continuous w/o Air
650C 5s
Cable & Connector 1.5m Cable with 2 Pin Lemo 0B
Coil Geometry Spiral
Coil
OD
inch 0.730
mm 18.25
Coil
ID
inch 0.250
mm 6.25
Sensor
inch 1.5 D x 3.0 H
mm 38mm x 76mm
Handle 300mm Long
Anchor Points Threaded Connection

Frequency Spectra & 3dB Beam Profiles



0 2000 4000 6000 8000 10000
2
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
R
e
s
p
o
n
s
e

(
m
V
)



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 15 of 163 InnerspecTechnologies
7.1.1.5. High Temperature L Wave Sensor (only for non-ferromagnetic materials)

Part Number 274A0128

Sensor Type L - Lorentz Permanent Magnet
Temperature Ranges
130C Continuous w/o Air
130C-450C Continuous with Air (2Bar)
450C-650C 30s with Air
Connector 2 Pin Lemo 0B
Coil Geometry Linearly Polarized
Coil
Width
inch 1.938
mm 49
Coil
Length
inch 1.440
mm 37
Sensor
inch 2.25 H x 3.75 W x 3.25 L
mm 57mm H x 95mm W x 83mm L
Air Coupling
NPT
M14 x 1.5 male adapter provided
Anchor Points 6 - #8-32 threaded holes

Frequency Spectra on aluminum & 3dB Beam Profiles







Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 16 of 163 InnerspecTechnologies
7.1.1.6. Ultra-High Temperature L Wave Sensor

Part Number 274A0143

Sensor Type UHT L - Lorentz Permanent Magnet
Temperature Ranges 1000C Continuous with Air and Water
Connector 2 Pin Lemo 0B
Coil Geometry Linearly Polarized
Coil
Width
inch 1.938
mm 49
Coil
Length
inch 1.440
mm 37
Sensor
inch 2.50 H x 3.25 W x 3.50 L
mm 64mm H x 83mm W x 89mm L
Air Coupling 1/4 NPT
Water Coupling 2 ea. NPT
Anchor Points 4 ea. M5 Holes

Frequency Spectra on aluminum & 3dB Beam Profiles





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 17 of 163 InnerspecTechnologies
7.1.2. Phased Array Sensors


Part
Number
Wave
Mode
Coil
Period
(Pitch)
No. of
Periods
Elevation
No. of
Channels
Maximum
Temp.
Connector Dim.
274A0133
1

SH

Pitch
Catch
4.76mm 8 29mm 8 80C 2-8 Pin DSub
1.63 H x 1.75
W x 2.28 D

41mm H x
45mm W x
58mm D
274A0149
SH

Pitch
Catch
3.2mm 8 25mm 8

80C
2 ea. Cables
w/ 16-pin
Lemo 3B
1.63 H x 1.75
W x 2.63 D

41mm H x
45mm W x
67mm D




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 18 of 163 InnerspecTechnologies
7.1.2.1. Phased Array 8-Channel SH (Pitch-Catch)

Part Number 274A0133

Sensor Type 8 Channel SH Magnet Array
Sensor Arrangement Pitch-Catch (2 sensors required)
Application
Inspection of Austenitic and Dissimilar
Metal Welds
Temperature Ranges <80C
RF Coil Geometry Meander
Connector 2-8 Pin DSub
Elevation 1.125 (29mm)
Channel Pitch 0.1875 (4.76mm)
Sensor
Dimensions
inch 1.63 H x 1.75 W x 2.28 D
mm 41mm H x 45mm W x 58mm D
Anchor Points Uses Fixture 160A0071


Frequency Spectra















Beam Profile (30 & 45)



0 200 400 600 800 1000 1200
0
1
2
3
4
5
6
7
8
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e
EPRISmall


x1 (mm)
x
3

(
m
m
)
Frequency = 0.60 MHz, FocalDistance= 3.0 inch, FocalAngle= 45 degree


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
5
10
15
20
25
30
35
x1 (mm)
x
3

(
m
m
)


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
5
10
15
20
25
30
35



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 19 of 163 InnerspecTechnologies
7.1.2.2. Phased Array 8-Channel SH (Pitch-Catch) Tandem Sensor

Part Number 274A0149

Sensor Type 8 Channel SH Magnet Array
Sensor Arrangement Pitch-Catch in Tandem (one sensor)
Application
Inspection of Austenitic and Dissimilar
Metal Welds
Temperature Ranges <80C
RF Coil Geometry Meander
Connector 2 ea. Cables w/ 16-pin Lemo 3B
Elevation 1.0 (25mm)
Channel Pitch 0.125(3.2mm)
Sensor
Dimensions
inch 1.63 H x 1.75 W x 2.63 D
mm 41mm H x 45mm W x 67mm D
Anchor Points 2 ea. #4-40 Holes


Frequency Spectra















Beam Profile (30 & 45)




0 200 400 600 800 1000 1200
0
1
2
3
4
5
6
7
8
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e
EPRISmall


x1 (mm)
x
3

(
m
m
)
Frequency = 0.60 MHz, FocalDistance= 3.0 inch, FocalAngle= 45 degree


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
5
10
15
20
25
30
35
x1 (mm)
x
3

(
m
m
)


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
5
10
15
20
25
30
35



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 20 of 163 InnerspecTechnologies
7.2. Sensors with Detachable RF Coil

Include Standard Probes and RF Coils (Sensor = Probe + RF Coil). The Probes can be used with different
RF Coils.

7.2.1. Permanent Magnet Probes

All probes are rated for maximum temperature of 80C except when noted otherwise.

Part Number Magnet Type
Magnetic
Field
Dimensions Instrument Other

274A0106
Medium
M

Permanent
0.5 x 0.5
face
Normal

PowerBox 1
PowerBox 2
PowerBox 8
Optional
Roller Kits
for scanning
274A0107
Large
L
Permanent
1 x 1 face
Normal

PowerBox 1
PowerBox 2
PowerBox 8
Optional
Roller Kits
for scanning
274A0144
Large
L
Permanent
1 x 1 face
Temp 200C
274A0120
Large Half
LH
Permanent
1 x 0.5 face
274A0121
Large Periodic
LA
Periodic
Magnets
274A0108
Extra Large
XL
Permanent
1.5 x 1.5
face
Normal

PowerBox 1
PowerBox 2
PowerBox 8
Optional
Roller Kits
for scanning
274A0124
L-Wave
LW
Permanent
L-Wave
Tangential
160A0046
TG-IS
Permanent Normal

PowerBox 1
PowerBox 2
PowerBox 8
Built-in
Rollers,
Encoder and
Alarm LEDs
(used for
thickness
mapping)




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 21 of 163 InnerspecTechnologies
7.2.2. Pulsed Magnet Probes

They rely mostly on magnetostriction and are used exclusively for inspection of magnetic materials.

Part
Number
Magnet
Type
Magnetic
Field
Dimensions Connectors Instrument Other
160A0062
Pulsed
Small
Lamb

Pulsed
Tangential
Lamb

1-Amphenol
PT for Pulsed
Magnet
Cable
PowerBox 1
or
PB 2 & PB8
+
PowerBox MP
Built-in
side
plates for
scanning
160A0049
Pulsed
Small
SH
Pulsed
Tangential
SH

1-Amphenol
PT for Pulsed
Magnet
Cable
PowerBox 1
or
PB 2 & PB8
+
PowerBox MP
Built-in
side
plates for
scanning
274A0076
Pulsed
Medium
Lamb
Pulsed
Tangential
Lamb
& Raleigh

1-Amphenol
PT for
Magnet
1-Lemo 0B
for RF Coil
Cable
1-FPC for RF
Coil
PowerBox 1
or
PB 2 & PB8
+
PowerBox MP
Built-in
side
plates for
scanning
274A0119
Pulsed
Medium SH
Pulsed
Tangential
SH

1-Amphenol
PT for
Magnet
1-Lemo 0B
for RF Coil
Cable
1-FPC for RF
Coil
PowerBox 1
or
PB 2 & PB8
+
PowerBox MP
Built-in
side
plates for
scanning
1-Amphenol
PT for
Magnet
1-Lemo 3B
for RF Coil
Cable
PowerBox 8
+
PowerBox MP
(Phased
Array)
Built-in
side
plates for
scanning




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 22 of 163 InnerspecTechnologies
7.2.3. Detachable RF Coils

In addition to complete Sensors with embedded RF Coils, Innerspec Technologies offers a wide range of
freestanding RF Coils to mount on the Standard Probes. These RF coils offer the following advantages:

- Low cost means of having several EMAT Sensors at a fraction of the expense of embedded versions.
- Inexpensive and easy to replace if damaged.
- Flexible coil substrate adapt to the undulations of the material thus reducing lift-off and improving
signal-to-noise (especially important for guided waves).
- Different wear surfaces can be adapted for unique applications.

All flexible RF Coils in this catalog have a maximum operating
temperature of 200C (400F) without active cooling

The Part Number printed on each RF Coil shows its unique characteristics in 8 separate fields.


XX XX X X.XXXxXX X.XXX X.XXXxXX

- Field 1. Coil Function. The options are:
o T: Transmitter
o R: Receiver
o T2: Unidirectional Transmitter. Two transmitter coils separated at approx. of a wavelength
o PE: Pulse-Echo. One coil in which the Transmitter is the same as Receiver
o PC: Pitch-Catch. Separate Transmitter and Receiver coils built in one flexible RF coil package
- Field 2. Compatible Standard Probe. The options are:
o M: Medium Permanent Magnet Probe (PN 274A0106)
o L: Large Permanent Magnet Probe (PN 274A0107 & 274A0120)
o XL: Extra Large (PN 274A0108)
o LW: L-Wave (PN 274A0128)
o LA: Large Periodic Magnet Array (PN 274A0121)
o SN (Number): Special + Number (e.g. 1). Used for special probes like 160A0046 TG-IS
o SE: Pulsed Electromagnet Small (PN 160A0062 & 160A0049)
o ME: Pulsed Electromagnet Medium (PN 274A0076 & 274A0119)
- Field 3. Coil Geometry. The options are:
o S: Spiral
o B: Butterfly
o R: Racetrack
o M: Meander. If it includes an F it is a meander focused coil
o PA: Phased Array. If it includes an F it is a Phased Array focused coil
- Fields 4, 5, 6, 7 & 8. Other relevant parameters particular to each RF Coil (different for each geometry).
7 & 8 are only applicable to Phased Array. The options are:

Coil
Geometry
Field 4 Field 5 Field 6 Field 7 Field 8
S OD - ID - -
B Coil Width - Coil Length - -
R Coil Width - Coil Length - -
M(F) Coil Period* No. Coil Periods Aperture - -
PA(F) Coil Period No. Coil Periods Elevation Pitch No. Channels
- On Meander Coils, Coil Period is usually referred to as the wavelength of the most efficiently excited
guided wave modes for that particular RF Coil.
1 2 3 4 6 5 7 8



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 23 of 163 InnerspecTechnologies
7.2.3.1. Normal (zero degree) RF Coils Tables

The RF Coils used for Normal (0 degree) inspection include:

Summary Table

Part Number
Compatible
Probe
Geometry
OD
(inch)
ID
(inch)
Width
(inch)
Length
(inch)
PE-M-S-0.730-0.250 274A0106 Spiral 0.730 0.250 - -
PE-L-S-0.730-0.250
274A0107
274A0144
Spiral 0.730 0.250 - -
PE-S1-0.350-0.639 160A0046 Butterfly - - 0.350 0.639
PE-L-B-0.726-0.492
274A0107
274A0144
274A0120
Butterfly - - 0.726 0.492
PE-L-B-1.218-0.950
274A0107
274A0144
Butterfly - - 1.218 0.950
PE-XL-B-1.218-0.950 274A0108 Butterfly - - 1.218 0.950
PE-LW-B-1.118-1.254 274A0124 Butterfly - - 0.986 1.254


In order to select the appropriate Probe and RF Coil, please note:

- Larger Probes incorporate larger magnets that provide greater signal-to-noise but can be unwieldy and
difficult to move on ferromagnetic parts.
- As with piezoelectric transducers, larger RF Coils concentrate the energy deeper into the material so
they have worse near-field sensitivity. Each RF Coil is provided with 3dB plots relative to their point of
maximum sensitivity.
- Butterfly Coils provide a linearly polarized wave that is very effective for coverage and sensitivity in flaw
detection, but will provide different velocity (and thickness) readings on anisotropic materials depending
on the orientation of the probe.
- Spiral Coils are less affected by anisotropy thus they are easier to use for thickness measurement in
anisotropic materials. Flaw detection is limited by their design.
- Permanent Magnet L-Wave coils are only appropriate for non-magnetic materials. Consult Innerspec
Technologies for L-Wave generation in ferromagnetic materials.










Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 24 of 163 InnerspecTechnologies
7.2.3.1.1. RF Coil: PE-M-S-0.730-0.250


Part Number PE-M-S-0.730-0.250
Connector 2 Pin Lemo 0B
Coil Function Transmitter and Receiver
Compatible Probe 274A0106
Coil Geometry Spiral
OD
inch 0.730
mm 18.25
ID
inch 0.250
mm 6.25

Frequency Spectra & 3dB Beam Profiles

0 2000 4000 6000 8000 10000
2
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
R
e
s
p
o
n
s
e

(
m
V
)



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 25 of 163 InnerspecTechnologies
7.2.3.1.2. RF Coil: PE-L-S-0.730-0.250


Part Number PE-L-S-0.730-0.250
Connector 2 Pin Lemo 0B
Coil Function Transmitter and Receiver
Compatible Probe 274A0107 & 274A0144
Coil Geometry Spiral
OD
inch 0.730
mm 18.25
ID
inch 0.250
mm 6.25


Frequency Spectra & 3dB Beam Profiles



0 2000 4000 6000 8000 10000
2
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
R
e
s
p
o
n
s
e

(
m
V
)



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 26 of 163 InnerspecTechnologies
7.2.3.1.3. RF Coil: PE-S1-0.350-0.639


Part Number PE-S1-0.350-0.639
Connector 2 Pin Lemo EPG 00
Coil Function Transmitter and Receiver
Compatible Probe 160A0046
Coil Geometry Butterfly
Width
inch 0.350
mm 8.89
Length
inch 0.639
mm 16.23

Frequency Spectra & 3dB Beam Profiles









Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 27 of 163 InnerspecTechnologies
7.2.3.1.4. RF Coils: PE-L-B-0.726-0.492


Part Number PE-L-B-0.726-0.492
Connector 2 Pin Lemo 0B
Coil Function Transmitter and Receiver
Compatible Probe 274A0107 & 274A0144 & 274A0120
Coil Geometry Butterfly
Width
inch 0.726
mm 18.15
Length
inch 0.492
mm 12.30

Frequency Spectra & 3dB Beam Profiles


0 2000 4000 6000 8000 10000
2
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
R
e
s
p
o
n
s
e

(
m
V
)



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 28 of 163 InnerspecTechnologies
7.2.3.1.5. RF Coils: PE-L-B-1.208-0.942


Part Number PE-L-B-1.208-0.942
Connector 2 Pin Lemo 0B
Coil Function Transmitter and Receiver
Compatible Probe 274A0107 & 274A0144
Coil Geometry Butterfly
Width
inch 1.218
mm 30.45
Length
inch 0.950
mm 23.75

Frequency Spectra & 3dB Beam Profiles



















0 2000 4000 6000 8000 10000
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
R
e
s
p
o
n
s
e

(
m
V
)



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 29 of 163 InnerspecTechnologies
7.2.3.1.6. RF Coils: PE-XL-B-1.218-0.950


Part Number PE-XL-B-1.218-0.950
Connector 2 Pin Lemo 0B
Coil Function Transmitter and Receiver
Compatible Probe 274A0108
Coil Geometry Butterfly
Width
inch 1.218
mm 30.45
Length
inch 0.950
mm 23.75

Frequency Spectra & 3dB Beam Profiles
0 2000 4000 6000 8000 10000
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
R
e
s
p
o
n
s
e

(
m
V
)






Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 30 of 163 InnerspecTechnologies
7.2.3.1.7. RF Coils: PE-LW-B-0.986-1.254


Part Number PE-LW-B-1.118-1.254
Connector 2 Pin Lemo 0B
Coil Function Transmitter and Receiver
Compatible Probe 274A0124
Coil Geometry Butterfly
Width
inch 0.986
mm 25.04
Length
inch 1.254
mm 31.85

Frequency Spectra (on aluminum with 0.25mm lift-off) & 3dB Beam Profiles




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 31 of 163 InnerspecTechnologies
7.2.3.2. Phased Array RF Coils

In addition to the complete Phased Array Sensors for SH Wave generation, Innerspec offers Phased Array
RF Coils for Shear Vertical Wave generation that can be attached to our standard probes. Shear Vertical
is the typical wave mode generated using standard piezoelectric transducers.

Summary Table

Part Number
Compatible
Probe
Wave Mode
Coil
Period
(Pitch)
No. of
Periods
Elevation Pitch
No. of
Channels
PE-L-PA-0.080x1-1.000-0.080x8
274A0144
(<200C)
SV 0.080 1 1.000 0.080 8
PE-L-PA-0.060x1-1.000-0.060x8
274A0144
(<200C)
SV
(Focused)
0.060 1 1.000 0.060 8
PE-L-PAF-0.080x1-1.000-0.080x8-2.000
274A0144
(<200C)
SV 0.080 1 1.000 0.080 8
PE-L-PAF-0.060x1-1.000-0.060x8-2.000
274A0144
(<200C)
SV
(Focused)
0.060 1 1.000 0.060 8



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 32 of 163 InnerspecTechnologies
7.2.3.2.1. RF Coils: Phased Array 8-Channel Shear Vertical Unfocused 0.080



Part Number PE-L-PA-0.080x1-1.000-0.080x8
Connector 2-8 Pin DSub
Coil Function Transmitter and Receiver
Compatible Probe 274A0144
Temperature Range <200C (400F)
RF Coil Geometry Phased Array
Coil Period 0.080
No. of Periods 1
Elevation 1.00 (25.4mm)
Channel Pitch 0.080 (2mm)
No. of Channels 8


Frequency Spectra
















Beam Profiles (45 and 60) Operating Frequency 1.5MHz

x1 (mm)
x
3

(
m
m
)


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
0
5
10
15
20
25
30
35
40
x1 (mm)
x
3

(
m
m
)


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
0
5
10
15
20
25
30
35
40
0 500 1000 1500 2000 2500 3000
1
2
3
4
5
6
7
8
9
10
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e


1500kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 33 of 163 InnerspecTechnologies
7.2.3.2.2. RF Coils: Phased Array 8-Channel Shear Vertical Unfocused 0.60



Part Number PE-L-PA-0.060x1-1.000-0.060x8
Connector 2-8 pin Lemo
Coil Function Transmitter and Receiver
Compatible Probe 274A0144
Temperature Range <200C (400F)
RF Coil Geometry Phased Array
Coil Period 0.06
No. of Periods 1
Elevation 1.00 (25.4mm)
Channel Pitch 0.060 (2mm)
No. of Channels 8


Frequency Spectra
















Beam Profiles (45 and 60) Operating Frequency 1.8MHz

x1 (mm)
x
3

(
m
m
)


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
0
5
10
15
20
25
30
35
40
x1 (mm)
x
3

(
m
m
)


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
0
5
10
15
20
25
30
35
40
0 500 1000 1500 2000 2500 3000
1
2
3
4
5
6
7
8
9
10
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e


1800kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 34 of 163 InnerspecTechnologies
7.2.3.2.3. RF Coils: Phased Array 8-Channel Shear Vertical Focused 0.080



Part Number PE-L-PAF-0.080x1-1.000-0.080x8-2.000
Connector 2-8pin Lemo
Coil Function Transmitter and Receiver
Compatible Probe 274A0144
Temperature Range <200C (400F)
RF Coil Geometry Phased Array
Coil Period 0.08
No. of Periods 1
Elevation 1.00 (25.4mm)
Channel Pitch 0.080 (2mm)
No. of Channels 8


Frequency Spectra

















Beam Profiles (45 and 60) Operating Frequency 1.5MHz

x1 (mm)
x
3

(
m
m
)


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
0
5
10
15
20
25
30
35
40
0 500 1000 1500 2000 2500 3000
1
2
3
4
5
6
7
8
9
10
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e


1500kHz
x1 (mm)
x
3

(
m
m
)


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
0
5
10
15
20
25
30
35
40



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 35 of 163 InnerspecTechnologies
7.2.3.2.4. RF Coils: Phased Array 8-Channel Shear Vertical Focused 0.060



Part Number PE-L-PAF-0.060x1-1.000-0.060x8-2.000
Connector 2-8pin Lemo
Coil Function Transmitter and Receiver
Compatible Probe 274A0144
Temperature Range <200C (400F)
RF Coil Geometry Phased Array
Coil Period 0.06
No. of Periods 1
Elevation 1.00 (25.4mm)
Channel Pitch 0.060 (2mm)
No. of Channels 8


Frequency Spectra


















Beam Profiles (45 and 60) Operating Frequency 1.8MHz

x1 (mm)
x
3

(
m
m
)


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
0
5
10
15
20
25
30
35
40
x1 (mm)
x
3

(
m
m
)


0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
0
5
10
15
20
25
30
35
40
0 500 1000 1500 2000 2500 3000
1
2
3
4
5
6
7
8
9
10
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e


1800kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 36 of 163 InnerspecTechnologies
7.2.3.3. Angled Beam and Guided Wave RF Coils

Angled Beam Bulk Waves and Guided Waves are generated using alternating magnetic fields created by
either a meander RF Coil or a set of periodic magnets on a racetrack or spiral RF coil. The table below
shows examples of Guided Wave magnet and RF Coil configurations.
Because of its mode-selection and non-contact characteristics, EMAT is by design very well suited to
efficiently generate all the Guided Wave modes included Rayleigh, Shear Horizontal and Lamb waves.




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 37 of 163 InnerspecTechnologies
7.2.3.3.1. One-Channel SH Wave with Permanent Magnets (Angle Steering with Frequency)

Mainly used for inspection of austenitic materials. Steering is achieved by changing the frequency of the
instrument. Only used in pitch-catch configuration with two probes (identical).


Part Number PC-LA-R-1.000-2.000
Connector 2 Pin Lemo 0B
Coil Function Transmitter or Receiver (Pitch Catch Configuration)
Compatible Probe 274A0121
Coil Geometry Racetrack
Wavelength 0.25
Frequency 600 to 800 kHz
Width
inch 1.000
mm 25.4mm
Length
inch 2.000
mm 50mm

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)
Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended
Frequency Range
3dB Range
Transmitter (kHz) Receiver (kHz)
LP-R-600 kHz 600 500-800 372-945 383-961

Frequency Spectra & 3dB Beam Profiles



























Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 38 of 163 InnerspecTechnologies
7.2.3.4. Guided Wave Setup Process

Guided Waves have different motion distribution depending on the geometry and characteristics of the
material that guides the sound. The introduction of boundary conditions make guided wave problems
inherently more difficult than bulk waves. Unlike the finite number of modes present in a bulk wave
problem, there are generally an infinite number of modes associated with a given guided wave problem.
That is, a finite body can support an infinite number of different guided wave modes.

This Catalog provides an example of the steps required in designing a guided wave inspection, and the
Dispersion Curves in Steel Plate.














* Innerspec Technologies offers a comprehensive software package designed to provide dispersion curves
for plates, tubes and rods in different materials (see temate

GWAT in the Software section of this


Catalog). In addition to the dispersion curves, the software includes all the RF Coils available in this
Catalog and can reference the right RF Coil for a specific mode thus considerably simplifying the setup
process.

Setup Process:

a. Determine Thickness of Test Sample ( h ).
b. Select Appropriate Mode. The user will need to determine the desired mode to be excited based
on wave mode analysis, finite element analysis (FEA), or empirical evidence. Mode selection
depends on the type and geometry of defects, geometry of the part and other variables (e.g.
environmental conditions of the sample).
c. Go to Phase Velocity Dispersion Curve ( Cp Vs fh ) and Group Velocity dispersion curve ( Cg Vs
fh ) for that material and confirm the adequacy of the mode.
- The Phase Velocity curve shows the mode separation for a given frequency-thickness.
The more separate a mode is from others, the easier it will be to generate without
interferences.
- The Group Velocity curve determines how that mode will travel in time with other modes.
This is important to know when designing the experiment since modes of different speeds
could interfere with each other at the time when the reading is to be taken.
d. Determine the EMAT Coil to use. Using the information from the Phase Velocity Dispersion Curve,
calculate the targeted wavelength for the specific mode.
h
fh
C
f
C
p p
|
|
.
|

\
|
= =
e. Select from the Catalog an RF Coil with a Period equal or close to the targeted wavelength.



f. Hardware Setup
The Dispersion Curves provided are NOT intended for:

- Other materials (other than steel)
- Anisotropic materials
- Multiple layered structures
- Tube, pipe, bar or other geometries
- Other wave modes

Contact Innerspec Technologies for additional assistance*





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 39 of 163 InnerspecTechnologies
- Frequency Selection. Once the mode is selected, frequency, phase velocity and group
velocity can be easily derived from the tables.
i. Using the ) , ( h f curve provided for each coil to determine the test frequency
0
f
ii. Using the ) , ( h C
g
curve provided for each coil to determine the group velocity of
the mode
0
g
C
iii. Phase velocity
0 0 0
f C
p
=
- Tuning Module Selection.
i. Select the tuning module for that particular RF Coil that covers the particular
frequency selected
0
f
ii. Insert Tuning Module in Signal Conditioning Box.
iii. Experienced users may also pickup the tuning module based on the frequency
spectrum provided in this catalog, or their on own experience.

Other Setup Tips:

a. The excitation is achieved with a tone burst signal of center frequency
0
f .
b. Number of cycles of the excitation signal can be changed depending on the inspection requirement.
- Time domain: More cycles result in longer pulse time which could affect resolution for Time-
Of-Flight calculations.
- Frequency domain: More cycles means narrower band and better mode selectivity.
- Amplitude: For non-dispersive and weak dispersive modes, more cycles typically result in
stronger signal. The peak amplitude of the signal will increase up to a point when
1 + =
R T t
N N N . Here
t
N ,
T
N , and
R
N are number of cycles in the excitation signal,
number of periods in the transmission coil, and the number of cycles in the receiving coil
respectively. For strongly dispersive modes, this rule is not applicable.
c. Time of expected signal package
- Estimate the distance of expected sound path l .
i. In through transmission, this is the distance between transmitter and receiver.
ii. In reflection, this is the distance of transmitter to reflector plus the distance of the
reflector to the receiver.
- Calculate the expected time of flight (TOF) of the signal:
l C t
g
=
0

- Set detection gate based on the expected TOF and/or its range.
d. For some steel products, the material property may vary from the standard property used in the
catalog. The test designer might need to change the test frequency around the theoretical value
0
f to optimize the test result.
e. A
0
and S
0
Lamb wave modes converges to Rayleigh wave at high frequency. Therefore, the
Rayleigh surface wave velocity can also be read from the dispersion curves shown here.



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 40 of 163 InnerspecTechnologies
7.2.3.4.1. Phase Velocity and Group Velocity Dispersion Curves in Steel Plate (Generic)

Lamb & Rayleigh Wave Dispersion Curves

Phase Velocity

Group Velocity






Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 41 of 163 InnerspecTechnologies
Shear Horizontal Wave Dispersion Curves

Phase Velocity

Group Velocity





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 42 of 163 InnerspecTechnologies
7.2.3.5. RF Coils for Angled Beam and Guided Waves (Lamb and Rayleigh) with Permanent Magnet
Probes (Summary Tables)

Part Number
Compatible
Probe
Function*
Coil Period
(inch)
Number of
periods
Aperture
(inch)
T-L-MF-0.024x15-0.680-5.000R
274A0107 &
274A0144
Transmitter 0.024 15 0.680
R-L-MF-0.024x15-0.680-1.000R
274A0107 &
274A0144
Receiver 0.024 15 0.680
T-L-MF-0.032x12-0.715-5.000R
274A0107 &
274A0144
Transmitter 0.032 12 0.715
R-L-MF-0.032x12-0.680-1.000R
274A0107 &
274A0144
Receiver 0.032 12 0.680
T-L-M-0.060x12-1.000
274A0107 &
274A0144
Transmitter 0.060 12 1.000
R-L-M-0.060x12-1.000
274A0107 &
274A0144
Receiver 0.060 12 1.000
T-L-M-0.070x10-1.000
274A0107 &
274A0144
Transmitter 0.070 10 1.000
R-L-M-0.070x10-1.000
274A0107 &
274A0144
Receiver 0.070 10 1.000
T-L-M-0.080x8-1.000
274A0107 &
274A0144
Transmitter 0.080 8 1.000
R-L-M-0.080x8-1.000
274A0107 &
274A0144
Receiver 0.080 8 1.000
T-L-M-0.100x7-1.000
274A0107 &
274A0144
Transmitter 0.100 7 1.000
R-L-M-0.100x7-1.000
274A0107 &
274A0144
Receiver 0.100 7 1.000
T-L-M-0.120x5-1.000
274A0107 &
274A0144
Transmitter 0.120 5 1.000
R-L-M-0.120x5-1.000
274A0107 &
274A0144
Receiver 0.120 5 1.000
T-L-M-0.140x6-1.000
274A0107 &
274A0144
Transmitter 0.140 6 1.000
R-L-M-0.140x6-1.000
274A0107 &
274A0144
Receiver 0.140 6 1.000
T-L-M-0.160x5-1.000
274A0107 &
274A0144
Transmitter 0.160 5 1.000
R-L-M-0.160x5-1.000
274A0107 &
274A0144
Receiver 0.160 5 1.000
T-L-M-0.180x5-1.000
274A0107 &
274A0144
Transmitter 0.180 5 1.000
R-L-M-0.180x5-1.000
274A0107 &
274A0144
Receiver 0.180 5 1.000
T-L-M-0.200x4-1.000
274A0107 &
274A0144
Transmitter 0.200 4 1.000
R-L-M-0.200x4-1.000
274A0107 &
274A0144
Receiver 0.200 4 1.000
T-L-M-0.250x4-1.000
274A0107 &
274A0144
Transmitter 0.250 4 1.000
R-L-M-0.250x4-1.000
274A0107 &
274A0144
Receiver 0.250 4 1.000
T-L-M-0.300x3-1.000
274A0107 &
274A0144
Transmitter 0.300 3 1.000
R-L-M-0.300x3-1.000
274A0107 &
274A0144
Receiver 0.300 3 1.000
T-L-M-0.400x2-1.000
274A0107 &
274A0144
Transmitter 0.400 2 1.000
R-L-M-0.400x2-1.000
274A0107 &
274A0144
Receiver 0.400 2 1.000
T-L-M-0.500x2-1.000
274A0107 &
274A0144
Transmitter 0.500 2 1.000
R-L-M-0.500x2-1.000
274A0107 &
274A0144
Receiver 0.500 2 1.000





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 43 of 163 InnerspecTechnologies
Typical operation range for Steel Plate

Wavelength
Part Number
Thickness
Range (mm)
Operating Frequency
Range (kHz)* inch mm
0.24 0.61
T-L-MF-0.024x15-0.680-5.000R
R-L-MF-0.024x15-0.680-1.000R
Min 0.05 1000
Max 1 10000
0.32 0.81
T-L-MF-0.032x12-0.715-5.000R
R-L-MF-0.032x12-0.680-1.000R
Min 0.05 1000
Max 1 10000
0.06 1.52
T-L-M-0.060x12-1.000
R-L-M-0.060x12-1.000
Min 0.05 200
Max 5 6000
0.07 1.78
T-L-M-0.070x8-1.000
R-L-M-0.070x8-1.000
Min 0.1 200
Max 6 6000
0.08 2.03
T-L-M-0.080x8-1.000
R-L-M-0.080x8-1.000
Min 0.1 200
Max 6 6000
0.10 2.54
T-L-M-0.100x5-1.000
R-L-M-0.100x5-1.000
Min 0.1 200
Max 6 6000
0.12 3.05
T-L-M-0.120x5-1.000
R-L-M-0.120x5-1.000
Min 0.2 200
Max 6 6000
0.14 3.55
T-L-M-0.140x6-1.000
R-L-M-0.140x6-1.000
Min 0.2 100
Max 7 5000
0.16 4.06
T-L-M-0.160x5-1.000
R-L-M-0.160x5-1.000
Min 0.25 100
Max 8 5000
0.18 4.57
T-L-M-0.180x5-1.000
R-L-M-0.180x5-1.000
Min 0.25 100
Max 10 4000
0.20 5.08
T-L-M-0.200x4-1.000
R-L-M-0.200x4-1.000
Min 0.25 100
Max 10 4000
0.25 6.35
T-L-M-0.250x4-1.000
R-L-M-0.250x4-1.000
Min 0.5 100
Max 12 3000
0.30 7.62
T-L-M-0.300x3-1.000
R-L-M-0.300x3-1.000
Min 0.5 100
Max 15 2500
0.40 10.2
T-L-M-0.400x2-1.000
R-L-M-0.400x2-1.000
Min 1 100
Max 20 2000
0.50 12.7
T-L-M-0.500x2-1.000
R-L-M-0.500x2-1.000
Min 2 50
Max 20 1500

- The RF Coil requires different hardware settings of the Signal Conditioning Box for different
frequencies. These settings are achieved using Tuning Modules that cover particular frequency
ranges. Check the Tuning Module Data Sheet of the RF Coil for available options.



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 44 of 163 InnerspecTechnologies
7.2.3.5.1. RF Coils: T-L-MF-0.024x15-0.715-5.000R & R-L-MF-0.024x15-0.680-1.600R



Part Number T-L-MF-0.024x15-0.680-5.000R R-L-MF-0.024x15-0.680-1.600R
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Focused Meander Focused
Meander
Period
inch 0.024 0.024
mm 0.61 0.61
Number of
Periods
15 15
Overall
Depth
inch 0.36 0.36
mm 9.14 9.14
Aperture
inch 0.715 0.680
mm 18.16 17.27
Focal
Distance
Inch 5 1
mm 127 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module Name
Tuning Frequency
(kHz)
Recommended Frequency Range
3dB Range
Transmitter (kHz) Receiver (kHz)
L/SE-PC-MF-0.024-3000kHz
L/SE-PE-MF-0.024-3000kHz
3000 1000-3500 1915-4210 2084-4258
L/SE-PC-MF-0.024-5000kHz
L/SE-PE-MF-0.024-5000kHz
5000 3500-6000 3073-7327 3293-7067
L/SE-PC-MF-0.024-8000kHz
L/SE-PE-MF-0.024-8000kHz
8000 6000-12000 4644-12080 4724-11740

Frequency Spectra

Transmitter Receiver

0 2000 4000 6000 8000 10000 12000 14000 16000
0
5
10
15
20
25
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e
TLMF24


3000kHz
5000kHz
8000kHz
0 2000 4000 6000 8000 10000 12000 14000 16000
0
5
10
15
20
25
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e
RLMF24


3000kHz
5000kHz
8000kHz





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 45 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.024 (0.61mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.

0 0.2 0.4 0.6 0.8 1
0
2
4
6
8
10
12
14
Thickness (mm)
F
r
e
q
u
e
n
c
y

(
M
H
z
)
Coil period 0.024 inch


A0
S0
A1
S1
S2
A2
A3
S3
A4
S4
S5
A5
A6
S6

0 0.2 0.4 0.6 0.8 1
0
1
2
3
4
5
6
Thickness (mm)
G
r
o
u
p

V
e
l
o
c
i
t
y

(
m
m
/
u
s
)
Coil period 0.024 inch


A0
S0
A1
S1
S2
A2
A3
S3
A4
S4
S5
A5
A6
S6










Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 46 of 163 InnerspecTechnologies
Illustration of Focusing Effect





































-50 0 50
20
40
60
80
100
120
Beam Intensity Plot : Transmitter
X (mm)

Y

(
m
m
)
-50 0 50
20
40
60
80
100
120
Beam Intensity Plot : Receiver
X (mm)
Y

(
m
m
)



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 47 of 163 InnerspecTechnologies
7.2.3.5.2. RF Coils: T-L-MF-0.032x12-0.715-5.000R & R-L-MF-0.032x12-0.680-1.600R



Part Number T-L-MF-0.032x12-0.715-5.000R R-L-MF-0.032x12-0.680-1.600R
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Focused Meander Focused
Meander
Period
inch 0.32 0.32
mm 8.13 8.13
Number of
Periods
12 12
Overall
Depth
inch 0.384 0.384
mm 9.75 9.75
Aperture
inch 0.715 0.680
mm 18.16 17.27
Focal
Distance
Inch 5 1
mm 127 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-MF-0.032-2500kHz
L/SE-PE-MF-0.032-2500kHz
2500 800-3000 1686-3458 1761-3428
L/SE-PC-MF-0.032-3500kHz
L/SE-PE-MF-0.032-3500kHz
3500 3000-4500 2340-4883 2403-4911
L/SE-PC-MF-0.032-7000kHz
L/SE-PE-MF-0.032-7000kHz
7000 4500-12000 4190-10342 4190-10780

Frequency Spectra
Transmitter Receiver

0 2000 4000 6000 8000 10000 12000 14000
0
5
10
15
20
25
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e
TLMF32


2500kHz
3500kHz
7000kHz
0 2000 4000 6000 8000 10000 12000 14000
2
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e
RLMF32


2500kHz
3500kHz
7000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 48 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.032 (0.81mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.

0 0.2 0.4 0.6 0.8 1
0
2
4
6
8
10
12
Thickness (mm)
F
r
e
q
u
e
n
c
y

(
M
H
z
)
Coil period 0.032 inch


A0
S0
A1
S1
S2
A2
A3
S3
A4
S4
S5
A5
A6
S6

0 0.2 0.4 0.6 0.8 1
0
1
2
3
4
5
6
Thickness (mm)
G
r
o
u
p

V
e
l
o
c
i
t
y

(
m
m
/
u
s
)
Coil period 0.032 inch


A0
S0
A1
S1
S2
A2
A3
S3
A4
S4
S5
A5
A6
S6




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 49 of 163 InnerspecTechnologies
Illustration of Focusing Effect

-50 0 50
20
40
60
80
100
120
Beam Intensity Plot : Transmitter
X (mm)

Y

(
m
m
)
-50 0 50
20
40
60
80
100
120
Beam Intensity Plot : Receiver
X (mm)
Y

(
m
m
)








Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 50 of 163 InnerspecTechnologies
7.2.3.5.3. RF Coils: T-L-M-0.060x12-1.000 & R-L-M-0.060x12-1.000



Part Number T-L-M-0.060x12-1.000 R-L-M-0.060x12-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.060 0.060
mm 1.524 1.524
Number of Periods 12 12
Overall
Depth
inch 0.705 0.705
mm 17.9 17.9
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.060-1600kHz
L/SE-PE-M-0.060-1600kHz
1600 600-1800 1198-2143 951-2527
L/SE-PC-M-0.060-2000kHz
L/SE-PE-M-0.060-2000kHz
2000 1800-2400 1485-2707 1185-3339
L/SE-PC-M-0.060-3500kHz
L/SE-PE-M-0.060-3500kHz
3500 2400-6000 2347-5206 1772-6706

Frequency Spectra

Transmitter Receiver








Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 51 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.06 (1.52mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.










Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 52 of 163 InnerspecTechnologies
7.2.3.5.4. RF Coils: T-L-M-0.070x10-1.000 & R-L-M-0.070x10-1.000



Part Number T-L-M-0.070x10-1.000 R-L-M-0.070x10-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible
Probe
274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.070 0.070
mm 1.78 1.78
Number of
Periods
10 10
Overall
Depth
inch 0.683 0.683
mm 17.3 17.3
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.070-1300kHz
L/SE-PE-M-0.070-1300kHz
1300 600-1400 968-1684 845-2014
L/SE-PC-M-0.070-1800kHz
L/SE-PE-M-0.070-1800kHz
1800 1400-2200 1347-2476 1100-2948
L/SE-PC-M-0.070-3000kHz
L/SE-PE-M-0.070-3000kHz
3000 2200-6000 2036-4210 1574-5435

Frequency Spectra

Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 53 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.07 (1.78mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 54 of 163 InnerspecTechnologies
7.2.3.5.5. RF Coils: T-L-M-0.080x8-1.000 & R-L-M-0.080x8-1.000



Part Number T-L-M-0.080x8-1.000 R-L-M-0.080x8-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.080 0.080
mm 2.03 2.03
Number of Periods 8 8
Overall
Depth
inch 0.62 0.62
mm 15.75 15.75
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Tuning Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.080-1000kHz
L/SE-PE-M-0.080-1000kHz
1000 500-1200 778-1303 698-1472
L/SE-PC-M-0.080-1500kHz
L/SE-PE-M-0.080-1500kHz
1500 1200-1800 1132-1997 990-2168
L/SE-PC-M-0.080-2600kHz
L/SE-PE-M-0.080-2600kHz
2600 1800-6000 1864-3607 1494-4237

Frequency Spectra

Transmitter Receiver







Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 55 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.08 (2mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 56 of 163 InnerspecTechnologies
7.2.3.5.6. RF Coils: T-L-M-0.100x7-1.000 & R-L-M-0.100x7-1.000



Part Number T-L-M-0.100x7-1.000 R-L-M-0.100x7-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible
Probe
274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.100 0.100
mm 2.54 2.54
Number of
Periods
7 7
Overall
Depth
inch 0.675 0.675
mm 17.15 17.15
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.100-900kHz
L/SE-PE-M-0.100-900kHz
900 500-1000 691-1162 632-1317
L/SE-PC-M-0.100-1250kHz
L/SE-PE-M-0.100-1250kHz
1250 1000-1400 930-1616 858-1874
L/SE-PC-M-0.100-2000kHz
L/SE-PE-M-0.100-2000kHz
2000 1400-4000 1421-2630 1253-3207

Frequency Spectra

Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 57 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.10 (2.54mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.









Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 58 of 163 InnerspecTechnologies
7.2.3.5.7. RF Coils: T-L-M-0.120x5-1.000 & R-L-M-0.120x5-1.000



Part Number T-L-M-0.120x5-1.000 R-L-M-0.120x5-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.120 0.120
mm 3.05 3.05
Number of Periods 7 5
Overall
Depth
inch 0.570 0.570
mm 14.48 14.48
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.120-500kHz
L/SE-PE-M-0.120-500kHz
500 300-600 346-681 297-773
L/SE-PC-M-0.120-1000kHz
L/SE-PE-M-0.120-1000kHz
1000 600-1200 680-1412 568-1648
L/SE-PC-M-0.120-2000kHz
L/SE-PE-M-0.120-2000kHz
2000 1200-2500 1232-3196 896-3856
L/SE-PC-M-0.120-5000kHz
L/SE-PE-M-0.120-5000kHz
5000 2500-9000 2240-8870 1370-10000*

* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 2000 4000 6000 8000 10000
0
2
4
6
8
10
12
14
16
18
20
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
1000kHz
2000kHz
5000kHz

0 2000 4000 6000 8000 10000
0
5
10
15
20
25
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
1000kHz
2000kHz
5000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 59 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.120 (3mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 60 of 163 InnerspecTechnologies
7.2.3.5.8. RF Coils: T-L-M-0.140x6-1.000 & R-L-M-0.140x6-1.000



Part Number T-L-M-0.140x6-1.000 R-L-M-0.140x6-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.140 0.140
mm 3.556 3.556
Number of Periods 6 6
Overall
Depth
inch 0.805 0.805
mm 20.45 20.45
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.140-500kHz
L/SE-PE-M-0.140-500kHz
500 200-600 345-695 296-815
L/SE-PC-M-0.140-900kHz
L/SE-PE-M-0.140-900kHz
900 600-1100 612-1344 502-1587
L/SE-PC-M-0.140-1500kHz
L/SE-PE-M-0.140-1500kHz
1500 1100-3000 951-2399 684-3000


Frequency Spectra

Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 61 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.140 (3.56mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 62 of 163 InnerspecTechnologies
7.2.3.5.9. RF Coils: T-L-M-0.160x5-1.000 & R-L-M-0.160x5-1.000



Part Number T-L-M-0.160x5-1.000 R-L-M-0.160x5-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.160 0.160
mm 4.06 4.06
Number of Periods 5 5
Overall
Depth
inch 0.760 0.760
mm 19.30 19.30
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.160-500kHz
L/SE-PE-M-0.160-500kHz
500 200-600 359-697 287-815
L/SE-PC-M-0.160-750kHz
L/SE-PE-M-0.160-750kHz
750 600-800 522-1066 404-1283
L/SE-PC-M-0.160-1250kHz
L/SE-PE-M-0.160-1250kHz
1250 800-1500 810-1882 588-2500*
L/SE-PC-M-0.160-3000kHz
L/SE-PE-M-0.160-3000kHz
3000 1500-5000 1542-4980 883-6000*

* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 1000 2000 3000 4000 5000 6000
0
2
4
6
8
10
12
14
16
18
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
750kHz
1250kHz
3000kHz
0 1000 2000 3000 4000 5000 6000
4
6
8
10
12
14
16
18
20
22
24
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
750kHz
1250kHz
3000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 63 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.160 (4mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 64 of 163 InnerspecTechnologies
7.2.3.5.10. RF Coils: T-L-M-0.180x5-1.000 & R-L-M-0.180x5-1.000



Part Number T-L-M-0.180x5-1.000 R-L-M-0.180x5-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.180 0.180
mm 4.57 4.57
Number of
Periods
5 5
Overall
Depth
inch 0.855 0.855
mm 21.72 21.72
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.180-400kHz
L/SE-PE-M-0.180-400kHz
400 150-500 273-607 241-639
L/SE-PC-M-0.180-700kHz
L/SE-PE-M-0.180-700kHz
700 500-800 437-1102 402-1177
L/SE-PC-M-0.180-1200kHz
L/SE-PE-M-0.180-1200kHz
1200 800-2500 658-2054 605-2323


Frequency Spectra

Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 65 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.18 (4.57mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.









Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 66 of 163 InnerspecTechnologies
7.2.3.5.11. RF Coils: T-L-M-0.200x4-1.000 & R-L-M-0.200x4-1.000




Part Number T-L-M-0.200x4-1.000 R-L-M-0.200x4-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.200 0.200
mm 5.08 5.08
Number of Periods 4 4
Overall
Depth
inch 0.750 0.750
mm 19.05 19.05
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.200-500kHz
L/SE-PE-M-0.200-500kHz
500 200-600 330-730 251-953
L/SE-PC-M-0.200-1000kHz
L/SE-PE-M-0.200-1000kHz
1000 600-1200 582-1646 395-2000*
L/SE-PC-M-0.200-2000kHz
L/SE-PE-M-0.200-2000kHz
2000 1200-4000 916-3664 521-4000*

* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 500 1000 1500 2000 2500 3000 3500 4000
2
4
6
8
10
12
14
16
18
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
1000kHz
2000kHz


0 500 1000 1500 2000 2500 3000 3500 4000
4
6
8
10
12
14
16
18
20
22
24
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
1000kHz
2000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 67 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.200 (5mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 68 of 163 InnerspecTechnologies
7.2.3.5.12. RF Coils: T-L-M-0.250x4-1.000 & R-L-M-0.250x4-1.000



Part Number T-L-M-0.250x4-1.000 R-L-M-0.250x4-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.250 0.250
mm 6.35 6.35
Number of Periods 4 4
Overall
Depth
inch 0.938 0.938
mm 23.81 23.81
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.250-400kHz
L/SE-PE-M-0.250-400kHz
400 100-500 251-621 222-725
L/SE-PC-M-0.250-800kHz
L/SE-PE-M-0.250-800kHz
800 500-1000 429-1350 366-1600*
L/SE-PC-M-0.250-2000kHz
L/SE-PE-M-0.250-2000kHz
2000 1000-4000 740-3872 569-4000*

* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 500 1000 1500 2000 2500 3000 3500 4000
2
4
6
8
10
12
14
16
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


400kHz
800kHz
2000kHz


0 500 1000 1500 2000 2500 3000 3500 4000
4
6
8
10
12
14
16
18
20
22
24
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


400kHz
800kHz
2000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 69 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.250 (6.35mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 70 of 163 InnerspecTechnologies
7.2.3.5.13. RF Coils: T-L-M-0.300x3-1.000 & R-L-M-0.300x3-1.000



Part Number T-L-M-0.300x3-1.000 R-L-M-0.300x3-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.300 0.300
mm 7.62 7.62
Number of Periods 3 3
Overall
Depth
inch 0.825 0.825
mm 20.96 20.96
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.300-300kHz
L/SE-PE-M-0.300-300kHz
300 100-350 198-460 147-600*
L/SE-PC-M-0.300-700kHz
L/SE-PE-M-0.300-700kHz
700 350-800 393-1165 363-1400*
L/SE-PC-M-0.300-1500kHz
L/SE-PE-M-0.300-1500kHz
1500 800-2500 658-3000* 373-3000*

* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 500 1000 1500 2000 2500 3000
2
4
6
8
10
12
14
16
18
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


300kHz
700kHz
1500kHz


0 500 1000 1500 2000 2500 3000
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


300kHz
700kHz
1500kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 71 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.300 (7.62mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 72 of 163 InnerspecTechnologies
7.2.3.5.14. RF Coils: T-L-M-0.400x2-1.000 & R-L-M-0.400x2-1.000



Part Number T-L-M-0.400x2-1.000 R-L-M-0.400x2-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.400 0.400
mm 10.2 10.2
Number of Periods 2 2
Overall
Depth
inch 0.700 0.700
mm 17.78 17.78
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.400-200kHz
L/SE-PE-M-0.400-200kHz
200 100-250 120-312 114-400*
L/SE-PC-M-0.400-500kHz
L/SE-PE-M-0.400-500kHz
500 250-550 275-855 231-1000*
L/SE-PC-M-0.400-1000kHz
L/SE-PE-M-0.400-1000kHz
1000 550-2000 431-1647 343-2000*

* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 500 1000 1500 2000
1
2
3
4
5
6
7
8
9
10
11
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


200kHz
500kHz
1000kHz


0 500 1000 1500 2000
2
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


200kHz
500kHz
1000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 73 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.400 (10.2mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.






















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 74 of 163 InnerspecTechnologies
7.2.3.5.15. RF Coils: T-L-M-0.500x2-1.000 & R-L-M-0.500x2-1.000



Part Number T-L-M-0.500x2-1.000 R-L-M-0.500x2-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.500 0.500
mm 12.7 12.7
Number of Periods 2 2
Overall
Depth
inch 0.875 0.875
mm 22.2 22.2
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.500-200kHz
L/SE-PE-M-0.500-200kHz
200 20-250 136-296 72-400*
L/SE-PC-M-0.500-400kHz
L/SE-PE-M-0.500-400kHz
400 250-500 257-604 130-800*
L/SE-PC-M-0.500-1000kHz
L/SE-PE-M-0.500-1000kHz
1000 500-1500 541-1607 201-2000*

* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 500 1000 1500 2000
1
2
3
4
5
6
7
8
9
10
11
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


200kHz
400kHz
1000kHz


0 500 1000 1500 2000
4
6
8
10
12
14
16
18
20
22
24
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


200kHz
400kHz
1000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 75 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.500 (12.7mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 76 of 163 InnerspecTechnologies
7.2.3.6. RF Coils for Angled Beam and Guided Waves (Lamb, Rayleigh and SH) with Small Pulsed
Magnet Probes (Summary Tables)

Part Number
Compatible
Probe
Function*
Coil Period
(inch)
Number of
periods
Aperture
(inch)
T-SE-M-0.060x12-1.000
160A0062 &
160A0049
Transmitter 0.060 12 1.000
R-SE-M-0.060x12-1.000
160A0062 &
160A0049
Receiver 0.060 12 1.000
T-SE-M-0.070x10-1.000
160A0062 &
160A0049
Transmitter 0.070 10 1.000
R-SE-M-0.070x10-1.000
160A0062 &
160A0049
Receiver 0.070 10 1.000
T-SE-M-0.080x8-1.000
160A0062 &
160A0049
Transmitter 0.080 8 1.000
R-SE-M-0.080x8-1.000
160A0062 &
160A0049
Receiver 0.080 8 1.000
T-SE-M-0.100x7-1.000
160A0062 &
160A0049
Transmitter 0.100 7 1.000
R-SE-M-0.100x7-1.000
160A0062 &
160A0049
Receiver 0.100 7 1.000
T-SE-MF-0.100x6-1.000-7.000R
160A0062 &
160A0049
Transmitter 0.100 6 1.000
R-SE-M-0.100x6-1.000-1.000R
160A0062 &
160A0049
Receiver 0.100 6 1.000
T-SE-M-0.120x5-1.000
160A0062 &
160A0049
Transmitter 0.120 5 1.000
R-SE-M-0.120x5-1.000
160A0062 &
160A0049
Receiver 0.120 5 1.000
T-SE-MF-0.120x5-1.000-7.000R
160A0062 &
160A0049
Transmitter 0.120 5 1.000
R-SE-M-0.120x5-1.000-1.000R
160A0062 &
160A0049
Receiver 0.120 5 1.000
T-SE-M-0.140x6-1.000
160A0062 &
160A0049
Transmitter 0.140 6 1.000
R-SE-M-0.140x6-1.000
160A0062 &
160A0049
Receiver 0.140 6 1.000
T-SE-M-0.160x5-1.000
160A0062 &
160A0049
Transmitter 0.160 5 1.000
R-SE-M-0.160x5-1.000
160A0062 &
160A0049
Receiver 0.160 5 1.000
T-SE-M-0.180x5-1.000
160A0062 &
160A0049
Transmitter 0.180 5 1.000
R-SE-M-0.180x5-1.000
160A0062 &
160A0049
Receiver 0.180 5 1.000
T-SE-M-0.200x4-1.000
160A0062 &
160A0049
Transmitter 0.200 4 1.000
R-SE-M-0.200x4-1.000
160A0062 &
160A0049
Receiver 0.200 4 1.000
T-SE-M-0.250x4-1.000
160A0062 &
160A0049
Transmitter 0.250 4 1.000
R-SE-M-0.250x4-1.000
160A0062 &
160A0049
Receiver 0.250 4 1.000
T-SE-M-0.300x3-1.000
160A0062 &
160A0049
Transmitter 0.300 3 1.000
R-SE-M-0.300x3-1.000
160A0062 &
160A0049
Receiver 0.300 3 1.000
T-SE-M-0.400x2-1.000
160A0062 &
160A0049
Transmitter 0.400 2 1.000
R-SE-M-0.400x2-1.000
160A0062 &
160A0049
Receiver 0.400 2 1.000
T-SE-M-0.500x2-1.000
160A0062 &
160A0049
Transmitter 0.500 2 1.000
R-SE-M-0.500x2-1.000
160A0062 &
160A0049
Receiver 0.500 2 1.000




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 77 of 163 InnerspecTechnologies
Typical operation range for Steel Plate

Wavelength
Part Number
Thickness
Range (mm)
Operating Frequency
Range (kHz)* inch mm
0.06 1.52
T-SE-M-0.060x12-1.000
R-SE-M-0.060x12-1.000
Min 0.05 200
Max 5 6000
0.07 1.78
T-SE-M-0.070x8-1.000
R-SE-M-0.070x8-1.000
Min 0.1 200
Max 6 6000
0.08 2.03
T-SE-M-0.080x8-1.000
R-SE-M-0.080x8-1.000
Min 0.1 200
Max 6 6000
0.10 2.54
T-SE-M-0.100x5-1.000
R-SE-M-0.100x5-1.000
Min 0.1 200
Max 6 6000
0.10 2.54
T-SE-MF-0.100x6-1.000-7.000R
R-SE-M-0.100x6-1.000-1.000R
Min 0.1 200
Max 6 6000
0.12 3.05
T-SE-M-0.120x5-1.000
R-SE-M-0.120x5-1.000
Min 0.2 200
Max 6 6000
0.12 3.05
T-SE-MF-0.120x5-1.000-7.000R
R-SE-M-0.120x5-1.000-1.000R
Min 0.2 200
Max 6 6000
0.14 3.55
T-SE-M-0.140x6-1.000
R-SE-M-0.140x6-1.000
Min 0.2 100
Max 7 5000
0.16 4.06
T-SE-M-0.160x5-1.000
R-SE-M-0.160x5-1.000
Min 0.25 100
Max 8 5000
0.18 4.57
T-SE-M-0.180x5-1.000
R-SE-M-0.180x5-1.000
Min 0.25 100
Max 10 4000
0.20 5.08
T-SE-M-0.200x4-1.000
R-SE-M-0.200x4-1.000
Min 0.25 100
Max 10 4000
0.25 6.35
T-SE-M-0.250x4-1.000
R-SE-M-0.250x4-1.000
Min 0.5 100
Max 12 3000
0.30 7.62
T-SE-M-0.300x3-1.000
R-SE-M-0.300x3-1.000
Min 0.5 100
Max 15 2500
0.40 10.2
T-SE-M-0.400x2-1.000
R-SE-M-0.400x2-1.000
Min 1 100
Max 20 2000
0.50 12.7
T-SE-M-0.500x2-1.000
R-SE-M-0.500x2-1.000
Min 2 50
Max 20 1500

- The RF Coil requires different hardware settings of the Signal Conditioning Box for different
frequencies. These settings are achieved using Tuning Modules that cover particular frequency
ranges. Check the Tuning Module of the RF Coil for available options.




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 78 of 163 InnerspecTechnologies
7.2.3.6.1. RF Coils: T-SE-M-0.060x12-1.000 & R-SE-M-0.060x12-1.000



Part Number T-SE-M-0.060x12-1.000 R-SE-M-0.060x12-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Meander
Meander
Period
inch 0.060 0.060
mm 1.524 1.524
Number of Periods 12 12
Overall
Depth
inch 0.705 0.705
mm 17.9 17.9
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.060-1600kHz
L/SE-PE-M-0.060-1600kHz
1600 600-1800 1198-2143 951-2527
L/SE-PC-M-0.060-2000kHz
L/SE-PE-M-0.060-2000kHz
2000 1800-2400 1485-2707 1185-3339
L/SE-PC-M-0.060-3500kHz
L/SE-PE-M-0.060-3500kHz
3500 2400-6000 2347-5206 1772-6706


Frequency Spectra

Transmitter Receiver






Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 79 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.06 (1.52mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.











Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 80 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.06 (1.52mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate






Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 81 of 163 InnerspecTechnologies
7.2.3.6.2. RF Coils: T-SE-M-0.070x10-1.000 & R-SE-M-0.070x10-1.000



Part Number T-SE-M-0.070x10-1.000 R-SE-M-0.070x10-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Meander
Meander
Period
inch 0.070 0.070
mm 1.78 1.78
Number of Periods 10 10
Overall
Depth
inch 0.683 0.683
mm 17.3 17.3
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.070-1300kHz
L/SE-PE-M-0.070-1300kHz
1300 600-1400 968-1684 845-2014
L/SE-PC-M-0.070-1800kHz
L/SE-PE-M-0.070-1800kHz
1800 1400-2200 1347-2476 1100-2948
L/SE-PC-M-0.070-3000kHz
L/SE-PE-M-0.070-3000kHz
3000 2200-6000 2036-4210 1574-5435


Frequency Spectra

Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 82 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.07 (1.78mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 83 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.08 (2.0mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate








Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 84 of 163 InnerspecTechnologies
7.2.3.6.3. RF Coils: T-SE-M-0.080x8-1.000 & R-SE-M-0.080x8-1.000



Part Number T-SE-M-0.080x8-1.000 R-SE-M-0.080x8-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Meander
Meander
Period
inch 0.080 0.080
mm 2.03 2.03
Number of Periods 8 8
Overall
Depth
inch 0.62 0.62
mm 15.75 15.75
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.080-1000kHz
L/SE-PE-M-0.080-1000kHz
1000 500-1200 778-1303 698-1472
L/SE-PC-M-0.080-1500kHz
L/SE-PE-M-0.080-1500kHz
1500 1200-1800 1132-1997 990-2168
L/SE-PC-M-0.080-2600kHz
L/SE-PE-M-0.080-2600kHz
2600 1800-6000 1864-3607 1494-4237


Frequency Spectra

Transmitter Receiver






Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 85 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.08 (2mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.






















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 86 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.08 (2.0mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate












































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 87 of 163 InnerspecTechnologies
7.2.3.6.4. RF Coils: T-SE-M-0.100x7-1.000 & R-SE-M-0.100x7-1.000



Part Number T-SE-M-0.100x7-1.000 R-SE-M-0.100x7-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Meander
Meander
Period
inch 0.100 0.100
mm 2.54 2.54
Number of Periods 7 7
Overall
Depth
inch 0.675 0.675
mm 17.15 17.15
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.100-900kHz
L/SE-PE-M-0.100-900kHz
900 500-1000 691-1162 632-1317
L/SE-PC-M-0.100-1250kHz
L/SE-PE-M-0.100-1250kHz
1250 1000-1400 930-1616 858-1874
L/SE-PC-M-0.100-2000kHz
L/SE-PE-M-0.100-2000kHz
2000 1400-4000 1421-2630 1253-3207


Frequency Spectra

Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 88 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.10 (2.54mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.









Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 89 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.10 (2.54mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate






Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 90 of 163 InnerspecTechnologies
7.2.3.6.5. RF Coils: T-SE-MF-0.100x6-1.000-7.000R & R-SE-MF-0.100x6-1.000-1.000R



Part Number T-SE-MF-0.100x6-1.000-7.000R R-SE-M-0.100x6-1.000-1.000R
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Focused Meander Focused
Meander
Period
inch 0.100 0.100
mm 2.54 2.54
Number of
Periods
6 6
Overall
Depth
inch 0.6 0.6
mm 15.24 15.24
Aperture
inch 1.000 1.000
mm 25.4 25.4
Focal
Distance
Inch 7 1
mm 177.8 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-MF-0.100-800kHz
L/SE-PE-MF-0.100-800kHz
800 200-900 557-1154 552-1141
L/SE-PC-MF-0.100-1200kHz
L/SE-PE-MF-0.100-1200kHz
1200 900-1400 804-1720 833-1724
L/SE-PC-MF-0.100-2200kHz
L/SE-PE-MF-0.100-2200kHz
2200 1400-2500 1338-3523 1405-3492
L/SE-PC-MF-0.100-4000kHz
L/SE-PE-MF-0.100-4000kHz
4000 2500-6000 1993-6798 2114-7519

Frequency Spectra
Transmitter Receiver

0 1000 2000 3000 4000 5000 6000 7000 8000
0
5
10
15
20
25
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e
TSEMF100


800kHz
1200kHz
2200kHz
4000kHz

0 1000 2000 3000 4000 5000 6000 7000 8000
0
5
10
15
20
25
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e
RSEMF100


800kHz
1200kHz
2200kHz
4000kHz




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 91 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.10 (2.54mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.








Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 92 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.10 (2.54mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.








Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 93 of 163 InnerspecTechnologies
Illustration of Focusing Effect



-50 0 50
20
40
60
80
100
120
Beam Intensity Plot : Transmitter
X (mm)

Y

(
m
m
)
-50 0 50
20
40
60
80
100
120
Beam Intensity Plot : Receiver
X (mm)
Y

(
m
m
)








Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 94 of 163 InnerspecTechnologies
7.2.3.6.6. RF Coils: T-SE-M-0.120x5-1.000 & R-SE-M-0.120x5-1.000



Part Number T-SE-M-0.120x5-1.000 R-SE-M-0.120x5-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Meander
Meander
Period
inch 0.120 0.120
mm 3.05 3.05
Number of Periods 7 5
Overall
Depth
inch 0.570 0.570
mm 14.48 14.48
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.120-500kHz
L/SE-PE-M-0.120-500kHz
500 300-600 346-681 297-773
L/SE-PC-M-0.120-1000kHz
L/SE-PE-M-0.120-1000kHz
1000 600-1200 680-1412 568-1648
L/SE-PC-M-0.120-2000kHz
L/SE-PE-M-0.120-2000kHz
2000 1200-2500 1232-3196 896-3856
L/SE-PC-M-0.120-5000kHz
L/SE-PE-M-0.120-5000kHz
5000 2500-9000 2240-8870 1370-10000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 2000 4000 6000 8000 10000
0
2
4
6
8
10
12
14
16
18
20
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
1000kHz
2000kHz
5000kHz


0 2000 4000 6000 8000 10000
0
5
10
15
20
25
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
1000kHz
2000kHz
5000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 95 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.120 (3mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 96 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.120 (3.0mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate





















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 97 of 163 InnerspecTechnologies
7.2.3.6.7. RF Coils: T-SE-MF-0.120x5-1.000-7.000R & R-SE-MF-0.120x5-1.000-1.000R



Part Number T-SE-MF-0.120x5-1.000-7.000R R-SE-M-0.120x5-1.000-1.000R
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Focused Meander Focused
Meander
Period
inch 0.120 0.120
mm 3.05 3.05
Number of
Periods
5 5
Overall
Depth
inch 0.6 0.6
mm 15.24 15.24
Aperture
inch 1.000 1.000
mm 25.4 25.4
Focal
Distance
Inch 7 1
mm 177.8 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)
Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.120-500kHz
L/SE-PE-M-0.120-500kHz
500 200-700 356-706 337-738
L/SE-PC-M-0.120-1000kHz
L/SE-PE-M-0.120-1000kHz
1000 700-1300 490-1555 702-1397
L/SE-PC-M-0.120-2000kHz
L/SE-PE-M-0.120-2000kHz
2000 1300-2400 1109-3111 1325-3159
L/SE-PC-M-0.120-5000kHz
L/SE-PE-M-0.120-5000kHz
5000 2400-6000 2412-8908 2372-8738
* The +3dB range is greater than twice of the tuning frequency
Frequency Spectra
Transmitter Receiver

0 2000 4000 6000 8000 10000
0
5
10
15
20
25
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e
TSEMF120


500kHz
1000kHz
2000kHz
5000kHz
0 2000 4000 6000 8000 10000
0
5
10
15
20
25
Frequency (kHz)
V
o
l
t
a
g
e

R
e
s
p
o
n
s
e
RSEMF120


500kHz
1000kHz
2000kHz
5000kHz

Lamb & Rayleigh Dispersion Curves for RF Coils with 0.120 (3mm) Coil Period



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 98 of 163 InnerspecTechnologies
The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.

































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 99 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.120 (3.0mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate




























Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 100 of 163 InnerspecTechnologies
Illustration of Focusing Effect


-50 0 50
20
40
60
80
100
120
Beam Intensity Plot : Transmitter
X (mm)

Y

(
m
m
)
-50 0 50
20
40
60
80
100
120
Beam Intensity Plot : Receiver
X (mm)
Y

(
m
m
)










Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 101 of 163 InnerspecTechnologies
7.2.3.6.8. RF Coils: T-SE-M-0.140x6-1.000 & R-SE-M-0.140x6-1.000



Part Number T-SE-M-0.140x6-1.000 R-SE-M-0.140x6-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.140 0.140
mm 3.556 3.556
Number of Periods 6 6
Overall
Depth
inch 0.805 0.805
mm 20.45 20.45
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.140-500kHz
L/SE-PE-M-0.140-500kHz
500 200-600 345-695 296-815
L/SE-PC-M-0.140-900kHz
L/SE-PE-M-0.140-900kHz
900 600-1100 612-1344 502-1587
L/SE-PC-M-0.140-1500kHz
L/SE-PE-M-0.140-1500kHz
1500 1100-3000 951-2399 684-3000


Frequency Spectra

Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 102 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.140 (3.56mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.




























Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 103 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.140 (3.56mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 104 of 163 InnerspecTechnologies
7.2.3.6.9. RF Coils: T-SE-M-0.160x5-1.000 & R-SE-M-0.160x5-1.000



Part Number T-SE-M-0.160x5-1.000 R-SE-M-0.160x5-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Meander
Meander
Period
inch 0.160 0.160
mm 4.06 4.06
Number of Periods 5 5
Overall
Depth
inch 0.760 0.760
mm 19.30 19.30
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.160-500kHz
L/SE-PE-M-0.160-500kHz
500 200-600 359-697 287-815
L/SE-PC-M-0.160-750kHz
L/SE-PE-M-0.160-750kHz
750 600-800 522-1066 404-1283
L/SE-PC-M-0.160-1250kHz
L/SE-PE-M-0.160-1250kHz
1250 800-1500 810-1882 588-2500*
L/SE-PC-M-0.160-3000kHz
L/SE-PE-M-0.160-3000kHz
3000 1500-5000 1542-4980 883-6000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver


0 1000 2000 3000 4000 5000 6000
0
2
4
6
8
10
12
14
16
18
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
750kHz
1250kHz
3000kHz
0 1000 2000 3000 4000 5000 6000
4
6
8
10
12
14
16
18
20
22
24
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
750kHz
1250kHz
3000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 105 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.160 (4mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 106 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.160 (4.0mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate





















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 107 of 163 InnerspecTechnologies
7.2.3.6.10. RF Coils: T-SE-M-0.180x5-1.000 & R-SE-M-0.180x5-1.000



Part Number T-SE-M-0.180x5-1.000 R-SE-M-0.180x5-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0107 & 274A0120 274A0107 & 274A0120
Coil Geometry Meander Meander
Meander
Period
inch 0.180 0.180
mm 4.57 4.57
Number of Periods 5 5
Overall
Depth
inch 0.855 0.855
mm 21.72 21.72
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.180-400kHz
L/SE-PE-M-0.180-400kHz
400 150-500 273-607 241-639
L/SE-PC-M-0.180-700kHz
L/SE-PE-M-0.180-700kHz
700 500-800 437-1102 402-1177
L/SE-PC-M-0.180-1200kHz
L/SE-PE-M-0.180-1200kHz
1200 800-2500 658-2054 605-2323

Frequency Spectra

Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 108 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.18 (4.57mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.









Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 109 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.18 (4.57mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 110 of 163 InnerspecTechnologies
7.2.3.6.11. RF Coils: T-SE-M-0.200x4-1.000 & R-SE-M-0.200x4-1.000




Part Number T-SE-M-0.200x4-1.000 R-SE-M-0.200x4-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Meander
Meander
Period
inch 0.200 0.200
mm 5.08 5.08
Number of Periods 4 4
Overall
Depth
inch 0.750 0.750
mm 19.05 19.05
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.200-500kHz
L/SE-PE-M-0.200-500kHz
500 200-600 330-730 251-953
L/SE-PC-M-0.200-1000kHz
L/SE-PE-M-0.200-1000kHz
1000 600-1200 582-1646 395-2000*
L/SE-PC-M-0.200-2000kHz
L/SE-PE-M-0.200-2000kHz
2000 1200-4000 916-3664 521-4000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 500 1000 1500 2000 2500 3000 3500 4000
2
4
6
8
10
12
14
16
18
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
1000kHz
2000kHz



0 500 1000 1500 2000 2500 3000 3500 4000
4
6
8
10
12
14
16
18
20
22
24
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


500kHz
1000kHz
2000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 111 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.200 (5mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 112 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.200 (5.0mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate





















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 113 of 163 InnerspecTechnologies
7.2.3.6.12. RF Coils: T-SE-M-0.250x4-1.000 & R-SE-M-0.250x4-1.000



Part Number T-SE-M-0.250x4-1.000 R-SE-M-0.250x4-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Meander
Meander
Period
inch 0.250 0.250
mm 6.35 6.35
Number of Periods 4 4
Overall
Depth
inch 0.938 0.938
mm 23.81 23.81
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.250-400kHz
L/SE-PE-M-0.250-400kHz
400 100-500 251-621 222-725
L/SE-PC-M-0.250-800kHz
L/SE-PE-M-0.250-800kHz
800 500-1000 429-1350 366-1600*
L/SE-PC-M-0.250-2000kHz
L/SE-PE-M-0.250-2000kHz
2000 1000-4000 740-3872 569-4000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 500 1000 1500 2000 2500 3000 3500 4000
2
4
6
8
10
12
14
16
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


400kHz
800kHz
2000kHz



0 500 1000 1500 2000 2500 3000 3500 4000
4
6
8
10
12
14
16
18
20
22
24
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


400kHz
800kHz
2000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 114 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.250 (6.35mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 115 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.250 (6.35mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate






















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 116 of 163 InnerspecTechnologies
7.2.3.6.13. RF Coils: T-SE-M-0.300x3-1.000 & R-SE-M-0.300x3-1.000



Part Number T-SE-M-0.300x3-1.000 R-SE-M-0.300x3-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Meander
Meander
Period
inch 0.300 0.300
mm 7.62 7.62
Number of Periods 3 3
Overall
Depth
inch 0.825 0.825
mm 20.96 20.96
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.300-300kHz
L/SE-PE-M-0.300-300kHz
300 100-350 198-460 147-600*
L/SE-PC-M-0.300-700kHz
L/SE-PE-M-0.300-700kHz
700 350-800 393-1165 363-1400*
L/SE-PC-M-0.300-1500kHz
L/SE-PE-M-0.300-1500kHz
1500 800-2500 658-3000* 373-3000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 500 1000 1500 2000 2500 3000
2
4
6
8
10
12
14
16
18
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


300kHz
700kHz
1500kHz



0 500 1000 1500 2000 2500 3000
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


300kHz
700kHz
1500kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 117 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.300 (7.62mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 118 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.300 (7.62mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate

















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 119 of 163 InnerspecTechnologies
7.2.3.6.14. RF Coils: T-SE-M-0.400x2-1.000 & R-SE-M-0.400x2-1.000



Part Number T-SE-M-0.400x2-1.000 R-SE-M-0.400x2-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Meander
Meander
Period
inch 0.400 0.400
mm 10.2 10.2
Number of Periods 2 2
Overall
Depth
inch 0.700 0.700
mm 17.78 17.78
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.400-200kHz
L/SE-PE-M-0.400-200kHz
200 100-250 120-312 114-400*
L/SE-PC-M-0.400-500kHz
L/SE-PE-M-0.400-500kHz
500 250-550 275-855 231-1000*
L/SE-PC-M-0.400-1000kHz
L/SE-PE-M-0.400-1000kHz
1000 550-2000 431-1647 343-2000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 500 1000 1500 2000
1
2
3
4
5
6
7
8
9
10
11
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


200kHz
500kHz
1000kHz



0 500 1000 1500 2000
2
4
6
8
10
12
14
16
18
20
22
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


200kHz
500kHz
1000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 120 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.400 (10.2mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 121 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.400 (10.2mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate






















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 122 of 163 InnerspecTechnologies
7.2.3.6.15. RF Coils: T-SE-M-0.500x2-1.000 & R-SE-M-0.500x2-1.000



Part Number T-SE-M-0.500x2-1.000 R-SE-M-0.500x2-1.000
Connector 2 Pin Lemo 0B 2 Pin Lemo 0B
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 160A0062 & 160A0049 160A0062 & 160A0049
Coil Geometry Meander Meander
Meander
Period
inch 0.500 0.500
mm 12.7 12.7
Number of Periods 2 2
Overall
Depth
inch 0.875 0.875
mm 22.2 22.2
Aperture
inch 1.000 1.000
mm 25.4 25.4

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
L/SE-PC-M-0.500-200kHz
L/SE-PE-M-0.500-200kHz
200 20-250 136-296 72-400*
L/SE-PC-M-0.500-400kHz
L/SE-PE-M-0.500-400kHz
400 250-500 257-604 130-800*
L/SE-PC-M-0.500-1000kHz
L/SE-PE-M-0.500-1000kHz
1000 500-1500 541-1607 201-2000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra

Transmitter Receiver

0 500 1000 1500 2000
1
2
3
4
5
6
7
8
9
10
11
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


200kHz
400kHz
1000kHz



0 500 1000 1500 2000
4
6
8
10
12
14
16
18
20
22
24
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


200kHz
400kHz
1000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 123 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.500 (12.7mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 124 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.500 (12.7mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate




















































0 2 4 6 8 10 12 14 16 18 20
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
1.5
Thickness (mm)
F
r
e
q
u
e
n
c
y

(
M
H
z
)
Coil period 0.50 inch


SH0
SH1
SH2
SH3
SH4
SH5
SH6
SH7
SH8
SH9
0 2 4 6 8 10 12 14 16 18 20
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
2.6
2.8
3
3.2
3.4
3.6
3.8
4
Thickness (mm)
G
r
o
u
p

V
e
l
o
c
i
t
y

(
m
m
/
u
s
)
Coil period 0.50 inch


SH0
SH1
SH2
SH3
SH4
SH5
SH6
SH7
SH8
SH9



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 125 of 163 InnerspecTechnologies
7.2.3.7. RF Coils for Angled Beam and Guided Waves (Lamb and SH) with Medium Pulsed Magnet
Probes (Summary Tables)

Whereas the RF Coils for Permanent Magnets can only be used for generation of Lamb and Rayleigh
Waves, the Pulsed Magnet Probes can generate Lamb, Rayleigh and Shear Horizontal modes.

Part Number
Compatible
Probe
Function*
Coil Period
(inch)
Number of
periods
Aperture
(inch)
T-ME-M-0.080x12-2.000
274A0076 &
274A0119
Transmitter 0.080 12 2.000
R-ME-M-0.080x12-2.000
274A0076 &
274A0119
Receiver 0.080 12 2.000
T-ME-M-0.120x9-2.000
274A0076 &
274A0119
Transmitter 0.120 9 2.000
R-ME-M-0.120x9-2.000
274A0076 &
274A0119
Receiver 0.120 9 2.000
T-ME-M-0.160x7-2.000
274A0076 &
274A0119
Transmitter 0.160 7 2.000
R-ME-M-0.160x7-2.000
274A0076 &
274A0119
Receiver 0.160 7 2.000
T-ME-M-0.200x6-2.000
274A0076 &
274A0119
Transmitter 0.200 6 2.000
R-ME-M-0.200x6-2.000
274A0076 &
274A0119
Receiver 0.200 6 2.000
T-ME-M-0.250x5-2.000
274A0076 &
274A0119
Transmitter 0.250 5 2.000
R-ME-M-0.250x5-2.000
274A0076 &
274A0119
Receiver 0.250 5 2.000
T-ME-M-0.300x4-2.000
274A0076 &
274A0119
Transmitter 0.300 4 2.000
R-ME-M-0.300x4-2.000
274A0076 &
274A0119
Receiver 0.300 4 2.000
T-ME-M-0.400x4-2.000
274A0076 &
274A0119
Transmitter 0.400 4 2.000
R-ME-M-0.400x4-2.000
274A0076 &
274A0119
Receiver 0.400 4 2.000
T-ME-M-0.520x3-2.000
274A0076 &
274A0119
Transmitter 0.520 3 2.000
R-ME-M-0.520x3-2.000
274A0076 &
274A0119
Receiver 0.500 3 2.000
T-ME-M-0.640x2-2.000
274A0076 &
274A0119
Transmitter 0.640 2 2.000
R-ME-M-0.640x2-2.000
274A0076 &
274A0119
Receiver 0.640 2 2.000
T-ME-M-0.720x2-2.000
274A0076 &
274A0119
Transmitter 0.720 2 2.000
R-ME-M-0.720x2-2.000
274A0076 &
274A0119
Receiver 0.720 2 2.000











Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 126 of 163 InnerspecTechnologies

Wavelength
Part Number
Thickness
Range (mm)
Operating Frequency
Range (kHz)* inch mm
0.08 2.03
T-ME-M-0.080x12-2.000
R-ME-M-0.080x12-2.000
Min 0.1 200
Max 6 6000
0.12 3.05
T-ME-M-0.120x9-2.000
R-ME-M-0.120x9-2.000
Min 0.2 200
Max 6 6000
0.16 4.06
T-ME-M-0.160x7-2.000 R-
ME-M-0.160x7-2.000
Min 0.25 200
Max 8 5000
0.20 5.08
T-ME-M-0.200x6-2.000
R-ME-M-0.200x6-2.000
Min 0.25 100
Max 10 4000
0.25 6.35
T-ME-M-0.250x5-2.000
R-ME-M-0.250x5-2.000
Min 0.5 100
Max 12 3000
0.30 7.62
T-ME-M-0.300x4-2.000
R-ME-M-0.300x4-2.000
Min 0.5 100
Max 15 2500
0.40 10.2
T-ME-M-0.400x4-2.000
R-ME-M-0.400x4-2.000
Min 1 100
Max 20 2000
0.52 13.2
T-ME-M-0.520x3-2.000
R-ME-M-0.520x3-2.000
Min 2 50
Max 20 1500
0.64 16.3
T-ME-M-0.640x2-2.000
R-ME-M-0.640x2-2.000
Min 2 50
Max 20 1200
0.72 18.3
T-ME-M-0.720x2-2.000
R-ME-M-0.720x2-2.000
Min 2 50
Max 20 1000

- The RF Coil requires different hardware settings of the Signal Conditioning Box for different
frequencies. These settings are achieved using Tuning Modules that cover particular frequency
ranges. Check the Tuning Module Data Sheet (Modules shaded in red are the minimum
recommended) of the RF Coil for available options.





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 127 of 163 InnerspecTechnologies
7.2.3.7.1. RF Coils: T-ME-M-0.080x12-2.000 & R-ME-M-0.080x12-2.000




Part Number T-ME-M-0.080x7-1.000 R-ME-M-0.080x7-1.000
Connector RF Coil directly to FPC RF Coil directly to FPC
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0076 & 274A0119 274A0076 & 274A0119
Coil Geometry Meander Meander
Meander
Period
inch 0.080 0.080
mm 2.03 2.03
Number of Periods 12 12
Overall
Depth
inch 0.940 0.940
mm 23.88 23.88
Aperture
inch 2.000 2.000
mm 50.8 50.8
- Hourglass shaped RF Coil is designed to conform to tubular products when scanning along the
tube (axial direction)

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
ME-PC-M-0.080-1250kHz
ME-PE-M-0.080-1250kHz
1250 200-1600 855-1728 608-2328
ME-PC-M-0.080-2500kHz
ME-PE-M-0.080-2500kHz
2500 1600-3000 1520-4075 725-5000*
ME-PC-M-0.080-4000kHz
ME-PE-M-0.080-4000kHz
4000 3000-6000 2112-6888 1048-7584
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra
Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 128 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.08 (2mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 129 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.08 (2mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.




















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 130 of 163 InnerspecTechnologies
7.2.3.7.2. RF Coils: T-ME-M-0.120x9-2.000 & R-ME-M-0.120x9-2.000



Part Number T-ME-M-0.120x9-2.000 R-ME-M-0.120x9-2.000
Connector RF Coil directly to FPC RF Coil directly to FPC
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0076 & 274A0119 274A0076 & 274A0119
Coil Geometry Meander Meander
Meander
Period
inch 0.120 0.120
mm 3.05 3.05
Number of Periods 9 9
Overall
Depth
inch 1.05 1.05
mm 26.67 26.67
Aperture
inch 2.000 2.000
mm 50.8 50.8
- Hourglass shaped RF Coil is designed to conform to tubular products when scanning along the
tube (axial direction)
Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
ME-PC-M-0.120-800kHz
ME-PE-M-0.120-800kHz
800 200-1000 442-1317 360-1602
ME-PC-M-0.120-1000kHz** 1000** 500-1200 510-1784 456-2000
ME-PC-M-0.120-1800kHz
ME-PE-M-0.120-1800kHz
1800 1000-2200 746-3852 526-3600*
ME-PC-M-0.120-2500kHz
ME-PE-M-0.120-2500kHz
2500 1200-2800 875-5392 580-5000*
ME-PC-M-0.120-3000kHz
ME-PE-M-0.120-3000kHz
3000 2800-6000 912-6000* 594-5400
* The +3dB range is greater 2x tuning frequency ** Specifically provided to excite SH
0
mode
Frequency Spectra
Transmitter Receiver
0 1000 2000 3000 4000 5000 6000
4
6
8
10
12
14
16
18
20
22
24
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


800kHz
1000kHz
1800kHz
2500kHz
3000kHz

0 1000 2000 3000 4000 5000 6000
5
10
15
20
25
30
Frequency (kHz)
V
o
l
t
a
g
e

(
m
V
)


800kHz
1000kHz
1800kHz
2500kHz
3000kHz



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 131 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.120 (3mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 132 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.120 (3mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.




















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 133 of 163 InnerspecTechnologies
7.2.3.7.3. RF Coils: T-ME-M-0.160x7-2.000 & R-ME-M-0.160x7-2.000



Part Number T-ME-M-0.160x7-2.000 R-ME-M-0.160x7-2.000
Connector RF Coil directly to FPC RF Coil directly to FPC
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0076 & 274A0119 274A0076 & 274A0119
Coil Geometry Meander Meander
Meander
Period
inch 0.160 0.160
mm 4.06 4.06
Number of Periods 7 7
Overall
Depth
inch 1.08 1.08
mm 27.43 27.43
Aperture
inch 2.000 2.000
mm 50.8 50.8
- Hourglass shaped RF Coil is designed to conform to tubular products when scanning along the
tube (axial direction)

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
ME-PC-M-0.160-500kHz
ME-PE-M-0.160-500kHz
500 200-600 321-746 259-899
ME-PC-0.160-1250kHz
ME-PE-0.160-1250kHz
1250 600-1500 643-2235 452-2500*
ME-PC-M-0.160-1250kHz
ME-PE-M-0.160-1250kHz
2500 1500-5000 955-5380 575-5000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra
Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 134 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.160 (4mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 135 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.160 (4mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.




















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 136 of 163 InnerspecTechnologies
7.2.3.7.4. RF Coils: T-ME-M-0.200x6-2.000 & R-ME-M-0.200x6-2.000



Part Number T-ME-M-0.200x6-2.000 R-ME-M-0.200x6-2.000
Connector RF Coil directly to FPC RF Coil directly to FPC
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0076 & 274A0119 274A0076 & 274A0119
Coil Geometry Meander Meander
Meander
Period
inch 0.200 0.200
mm 5.08 5.08
Number of Periods 6 6
Overall
Depth
inch 1.150 1.150
mm 29.21 29.21
Aperture
inch 2.000 2.000
mm 50.8 50.8
- Hourglass shaped RF Coil is designed to conform to tubular products when scanning along the
tube (axial direction)

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
ME-PC-M-0.200-400kHz
ME-PE-M-0.200-400kHz
400 100-500 220-678 194-767
ME-PC-M-0.200-1000kHz
ME-PE-M-0.200-1000kHz
1000 500-1200 418-2176 330-2000*
ME-PC-M-0.200-2000kHz
ME-PE-M-0.200-2000kHz
2000 1200-4000 556-4640 396-4000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra
Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 137 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.200 (5mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 138 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.200 (5mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.




















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 139 of 163 InnerspecTechnologies
7.2.3.7.5. RF Coils: T-ME-M-0.250x5-2.000 & R-ME-M-0.250x5-2.000




Part Number T-ME-M-0.250x5-2.000 R-ME-M-0.250x5-2.000
Connector RF Coil directly to FPC RF Coil directly to FPC
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0076 & 274A0119 274A0076 & 274A0119
Coil Geometry Meander Meander
Meander
Period
inch 0.250 0.250
mm 6.35 3.35
Number of Periods 5 5
Overall
Depth
inch 1.188 1.188
mm 30.16 30.16
Aperture
inch 2.000 2.000
mm 50.8 50.8
- Hourglass shaped RF Coil is designed to conform to tubular products when scanning along the
tube (axial direction)

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
ME-PC-M-0.250-400kHz
ME-PE-M-0.250-400kHz
400 100-500 237-638 175-800*
ME-PC-M-0.250-800kHz
ME-PE-M-0.250-800kHz
800 500-1000 389-1502 248-1600*
ME-PC-M-0.250-1500kHz
ME-PE-M-0.250-1500kHz
1500 1000-3000 546-3316 303-3000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra
Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 140 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.250 (6.35mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 141 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.250 (6.35mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.



















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 142 of 163 InnerspecTechnologies
7.2.3.7.6. RF Coils: T-ME-M-0.300x4-2.000 & R-ME-M-0.300x4-2.000



Part Number T-ME-M-0.300x4-2.000 R-ME-M-0.300x4-2.000
Connector RF Coil directly to FPC RF Coil directly to FPC
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0076 & 274A0119 274A0076 & 274A0119
Coil Geometry Meander Meander
Meander
Period
inch 0.300 0.300
mm 7.62 7.62
Number of Periods 4 4
Overall
Depth
inch 1.125 1.125
mm 28.58 28.58
Aperture
inch 2.000 2.000
mm 50.8 50.8
- Hourglass shaped RF Coil is designed to conform to tubular products when scanning along the
tube (axial direction)

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
ME-PC-M-0.300-300kHz
ME-PE-M-0.300-300kHz
300 100-400 161-511 132-608
ME-PC-M-0.300-650kHz
ME-PE-M-0.300-650kHz
650 400-800 290-1354 203-1300*
ME-PC-M-0.300-1250kHz
ME-PE-M-0.300-1250kHz
1250 800-2500 398-3087 257-2500*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra
Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 143 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.300 (7.62mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 144 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.300 (7.62mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.




















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 145 of 163 InnerspecTechnologies
7.2.3.7.7. RF Coils: T-ME-M-0.400x4-2.000 & R-ME-M-0.400x4-2.000



Part Number T-ME-M-0.400x4-2.000 R-ME-M-0.400x4-2.000
Connector RF Coil directly to FPC RF Coil directly to FPC
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0076 & 274A0119 274A0076 & 274A0119
Coil Geometry Meander Meander
Meander
Period
inch 0.400 0.400
mm 10.2 10.2
Number of Periods 2 4
Overall
Depth
inch 1.5 1.5
mm 38.1 38.1
Aperture
inch 2.000 2.000
mm 50.8 50.8
- Hourglass shaped RF Coil is designed to conform to tubular products when scanning along the
tube (axial direction)

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
ME-PC-M-0.400-250kHz
ME-PE-M-0.400-250kHz
250 100-300 150-420 87-500*
ME-PC-M-0.400-500kHz
ME-PE-M-0.400-500kHz
500 300-600 239-893 123-1000*
ME-PC-M-0.400-1000kHz
ME-PE-M-0.400-1000kHz
1000 600-2000 354-2000* 148-2000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra
Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 146 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.400 (10.2mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 147 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.400 (10.2mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.






















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 148 of 163 InnerspecTechnologies
7.2.3.7.8. RF Coils: T-ME-M-0.520x3-2.000 & R-ME-M-0.520x3-2.000




Part Number T-ME-M-0.520x3-2.000 R-ME-M-0.520x3-2.000
Connector RF Coil directly to FPC RF Coil directly to FPC
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0076 & 274A0119 274A0076 & 274A0119
Coil Geometry Meander Meander
Meander
Period
inch 0.520 0.520
mm 13.2 13.2
Number of Periods 2 3
Overall
Depth
inch 1.43 1.43
mm 36.32 36.32
Aperture
inch 2.000 2.000
mm 50.8 50.8
- Hourglass shaped RF Coil is designed to conform to tubular products when scanning along the
tube (axial direction)


Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
ME-PC-M-0.520-150kHz
ME-PE-M-0.520-150kHz
150 50-200 90-238 57-300*
ME-PC-M-0.520-400kHz
ME-PE-M-0.520-400kHz
400 200-500 198-795 97-800*
ME-PC-M-0.520-750kHz
ME-PE-M-0.520-750kHz
750 500-1500 282-750 117-1500*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra
Transmitter Receiver




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 149 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.520 (12.7mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 150 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.520 (12.7mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.




















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 151 of 163 InnerspecTechnologies
7.2.3.7.9. RF Coils: T-ME-M-0.640x2-2.000 & R-ME-M-0.640x2-2.000



Part Number T-ME-M-0.640x2-2.000 R-ME-M-0.640x2-2.000
Connector RF Coil directly to FPC RF Coil directly to FPC
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0076 & 274A0119 274A0076 & 274A0119
Coil Geometry Meander Meander
Meander
Period
inch 0.640 0.640
mm 16.3 16.3
Number of Periods 2 2
Overall
Depth
inch 1.120 1.120
mm 28.45 28.45
Aperture
inch 2.000 2.000
mm 50.8 50.8
- Hourglass shaped RF Coil is designed to conform to tubular products when scanning along the
tube (axial direction)

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
ME-PC-M-0.640-150kHz
ME-PE-M-0.640-150kHz
150 50-200 89-240 58-300*
ME-PC-M-0.640-300kHz
ME-PE-M-0.640-300kHz
300 200-350 159-547 85-600*
ME-PC-M-0.640-500kHz
ME-PE-M-0.640-500kHz
500 350-1200 224-987 106-1000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra
Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 152 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.640 (16.3mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 153 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.640 (16.3mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.




















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 154 of 163 InnerspecTechnologies
7.2.3.7.10. RF Coils: T-ME-M-0.720x2-2.000 & R-ME-M-0.720x2-2.000



Part Number T-ME-M-0.640x2-2.000 R-ME-M-0.640x2-2.000
Connector RF Coil directly to FPC RF Coil directly to FPC
Coil Function Transmitter, bi-directional Receiver
Compatible Probe 274A0076 & 274A0119 274A0076 & 274A0119
Coil Geometry Meander Meander
Meander
Period
inch 0.720 0.720
mm 18.3 18.3
Number of Periods 2 2
Overall
Depth
inch 1.26 1.26
mm 32.00 32.00
Aperture
inch 2.000 2.000
mm 50.8 50.8
- Hourglass shaped RF Coil is designed to conform to tubular products when scanning along the
tube (axial direction)

Tuning Module Data Sheet (Modules shaded in red are the minimum recommended)

Tuning Setting Module
Name
Tuning
Frequency
(kHz)
Recommended Frequency
Range
3dB Range
Transmitter
(kHz)
Receiver
(kHz)
ME-PC-M-0.720-125kHz
ME-PE-M-0.720-125kHz
125 50-150 70-203 46-250*
ME-PC-M-0.720-250kHz
ME-PE-M-0.720-250kHz
250 150-300 125-500* 69-500*
ME-PC-M-0.720-500kHz
ME-PE-M-0.720-500kHz
500 300-1000 193-1000* 89-1000*
* The +3dB range is greater than twice of the tuning frequency

Frequency Spectra
Transmitter Receiver





Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 155 of 163 InnerspecTechnologies
Lamb & Rayleigh Dispersion Curves for RF Coils with 0.720 (18.3mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.























































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 156 of 163 InnerspecTechnologies
Shear Horizontal Dispersion Curves for RF Coils with 0.720 (18.3mm) Coil Period

The following sets of curves provide the Frequency and Corresponding Group Velocity for a given thickness
of Steel Plate.




















































Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 157 of 163 InnerspecTechnologies
8. Signal Conditioning Box (Remote Box)

Part
Number
Type &
Frequency
Probes &
Sensors
Minimum
Cables
Required*
Connector
Instrument
Connector
Probe
Dimensions
245A0136
1 Channel
Pulse-Echo
Normal
Beam
2-4MHz
All
Normal
Beam
except
160A0046

1-232A0294
1-232A0234
1-232A0296
1-232A0123
1-2 Pin Lemo
0B
1-BNC
1-Triax
1-2 Pin
Lemo 1B
1-2 Pin
Lemo 0B

3.42 x 5.15 x 1.86
87mm x 131mm x 47mm
Mounting Holes
1.57 x 5.39 (40mm x 137mm)
245A0142
1 Channel
Pulse-Echo
Normal Beam
1-2MHz
All
Normal
Beam
except
160A0046
1-232A0294
1-232A0234
1-232A0296
1-232A0123
1-2 Pin Lemo
0B
1-BNC
1-Triax
1-2 Pin
Lemo 1B
1-2 Pin
Lemo 0B
245A0132
2 Channel
Pitch-Catch
Angled Beam
& Guided
Waves

(includes 2
slots for
Tuning
Modules)
274A0106
274A0107
274A0120
274A0144
274A0108
160A0062
160A0049
160A0076
160A0119
1 Channel
1-232A0294
1-232A0234
1-232A0296
2-232A0123

2 Channel
1-232A0294
2-232A0234
2-232A0296
4-232A0123
4-2 Pin
Lemo 0B
2-BNC
2-Triax
2-6 Pin Lemo
1B
2 or 4-2 Pin
Lemo 0B



Box
4.25 x 6.77 x 2.50
108mm x 172mm x 64mm
Mounting Holes
2.36 x 7.18 (60mm x 182mm)
245A0145
8 Channel
Pitch-Catch
Phased Array

SH-750KHz
274A0133
274A0149
1-232A0294
1-232A0304
1-232A0305
2-232A0306
OR
4-232A0307
2-8 Pin DSub
Combo D
1-2 Pin
Lemo 1B
4-8 Pin
Lemo 1B
OR
2-18 Pin
Lemo 3B

Box
2.28 x 8.77 x 5.50
58mm x 223mm x 165mm
Mounting Holes
4.92 x 9.38 (125mm x 238mm)
245A0146
8 Channel
Pulse-Echo
Phased Array

SV-1-3MHz
274A0119
1-232A0294
1-232A0304
1-232A0305
2-232A0306
OR
4-232A0307
2-8 Pin DSub
Combo D
1-2 Pin
Lemo 1B
4-8 Pin
Lemo 1B
OR
2-18 Pin
Lemo 3B

- Can vary with each instrument and application. Consult Innerspec Technologies for assistance.



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 158 of 163 InnerspecTechnologies
9. Interconnecting Cables & Adapters

Part Number Length
Connector
Instrument
Connector
Signal
Cond. Box
Connector
Probe
Description
232A0123
2
(60cm)
1

NA
1-2 Pin
Lemo 0B
1-2 Pin
Lemo 0B
1 Channel (2 Pin) RF Coil Cable
232A0169
2
(60cm)
1

NA
1-6 Pin
Lemo 1B
1-6 Pin
Lemo 1B
2 Channel (6 Pin) RF Coil Cable
232A0306
2
(60cm)
1

NA
1-16 Pin
Lemo 3B
1-16 Pin
Lemo 3B
8 Channel (16 Pin) Transmit or
Receive RF Coil Cable
232A0307
2
(60cm)
1

NA
1-8 Pin
Lemo 1B
1-8 Pin
Lemo 1B
4 Channel (8 Pin) Transmit or
Receive RF Coil Cable
232A0234
6
(182cm)
2

1-Triax 1-Triax NA
1 Channel Transmit Cable for
PowerBox 1 & 2
232A0296
6
(182cm)
2

1-BNC 1-BNC NA
1 Channel Receive Cable for
PowerBox 1 & 2
232A0345
6
(182cm)
2

1-8 Pin DSub
Combo D
1-8 Pin DSub
Combo D
NA
8 Channel Transmit Cable for
PowerBox 8
232A0346
6
(182cm)
2

1-8 Pin DSub
Combo D
1-8 Pin DSub
Combo D
NA
8 Channel Receive Cable for
PowerBox 8
232A0303
6
(182cm)
2

1- 3 Pin
Amphenol PT
(for PB1)
NA
1- 3 Pin
Amphenol PT
Pulsed Magnet Cable for
PowerBox 1
232A0292
6
(182cm)
2

1- 3 Pin
Amphenol 97
(for PBMP)
NA
1- 3 Pin
Amphenol PT
Pulsed Magnet Cable for
PowerBox MP
232A0293
6
(182cm)
2

1- 3 Pin
Amphenol 97
(for PBMP)
NA
2- 3 Pin
Amphenol PT
Pulsed Magnet Cable for
PowerBox MP (2 sensors)
232A0294
6
(182cm)
2

1-DB25
1-2 Pin
Lemo 1B
NA
Signal Conditioning Box Power
Cable
232A0295
6
(182cm)
2

1-DB25
2-2 Pin
Lemo 1B
NA
Signal Conditioning Box Power
Cable (2 Boxes)
232A0296
3
(90cm)
1-BNC 1-BNC NA
Magnet Pulser Trigger Cable (PB 2
to PB MP)
232A0308
6
(182cm)
2

1-DB9 NA 1-8 Pin M12 PowerBox 1, 2 & 8 Encoder Cable
211M0001 6 NA
1-2 Pin
Lemo 1B
NA
Signal Conditioning Box Power
Supply
279A0006 NA BNC Triax NA
Adapter BNC-Triax Balun for Low
Frequency (0.1-1MHz)
3

279A0007 NA BNC Triax NA
Adapter BNC-Triax Balun for High
Frequency (1-5MHz)
3


1
Other lengths up to 4 (120cm) available upon request
2
Other lengths up to 150 (50m) available upon request
3
Used to connect to instruments that use standard BNC connectors for transmit



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 159 of 163 InnerspecTechnologies
10. Accessories

10.1. Wear Surfaces

Wear surfaces are used to protect the RF Coil when inspecting over rough surfaces. The wear surfaces
provided here have been tested by Innerspec Technologies in automated and manual inspections.

10.1.1. Metallic

Metallic Wear Surfaces are recommended only for Angled Beam (Magnetostrictive) and Guided Wave
Applications

Part
Number
Probe Dimensions
001F0785
274A0106
Medium
Rectangular
3.5 L x 0.875 W
86mm L x 21mm W
001F0786
274A0107 and 24A0120
Large
Rectangular
4.0 L x 1.125 W
98mm L x 28mm W
001F0787
274A0108
XLarge
Rectangular
5.0 L x 1.625 W
123mm L x 40mm W
001F0972
160A0062 & 160A0049
Pulsed Small Lamb or SH
Shaped
4.875 L x 1.375 W
119mm L x 34mm W
001F0675
160A0062 & 160A0049
Pulsed Small Lamb or SH
Rectangular
4.875 L x 1.375 W
119mm L x 34mm W
280F0084
274A0076 & 274A0119
Pulsed Medium Lamb or SH
Shaped*
6.313 L x 2.250 W
155mm L x 55mm W
280F0085
274A0076 & 274A0119
Pulsed Medium Lamb or SH
Rectangular
6.313 L x 2.250 W
155mm L x 55mm W

- Hourglass shaped wear surface is designed to conform to tubular products when scanning along
the tube (axial direction)

10.1.2. Non-Metallic

Non-Metallic Wear Surfaces are recommended for Normal Beam Applications and High Temperature
Angled Beam, Guided Waves and Phased Array.

Part Number Application Dimensions & Length
510V00005 Normal Beam up to 100C
High Resistance Wear Surface Tape Roll
0.010" Thick 2 x 5 yds
510V00006
Guided Waves, Angled Beam and
SV Phased Array at up to 200C
High Resistance Wear Surface Tape Roll
0.005" Thick 2 x 5 yds
510V00008 SH Phased Array Sensors up to 80C
High Resistance Wear Surface Tape Roll
0.002" Thick 2 x 5 yds



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 160 of 163 InnerspecTechnologies
10.2. Compliance Spring Foam

Compliance spring foam is used to maintain flexible RF coils close to the part. The foam is engineered to
maintain its shape in dirty or wet environments and apply very low pressure on the coil to minimize wear.

Part
Number
Description Order Quantity Probes
001V00014
1/8 Gray Foam for Permanent
Magnet Probes

24 x 24 Sheet
274A0106
274A0107
274A0120
274A0121
274A0108
274A0128
001F0680
Straight White Foam for Small
Pulsed Electromagnet Probes
Unit
160A0049
160A0062
001F0404
Shaped White Foam for Medium
Pulsed Electromagnet Probes
Unit

274A0076
274A0119
001V00015 High-Temperature Foam (200C) 2 x 7 Strip 274A0144



10.3. RF Coil Fasteners

Detachable RF Coils are attached to the Probes using different types of fastening screws. Use the table
below to order spares.

Part
Number
Description Probes
510V0001
Set of 4 Thumbscrews
6/32-3/8
274A0106
274A0107
274A0144
274A0120
274A0121
274A0108
274A0128
160A0049
160A0062
510V0002
Set of 4 Thumbscrews
8/32-3/8
274A0076
274A0119
510V0003
Set of 4 Shoulder Screws
3/16 1-1/4
160A0046



Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 161 of 163 InnerspecTechnologies
10.4. Sensor & Probe Fixtures

Roller-Kit assemblies are recommended for scanning ferromagnetic parts with Permanent Magnet Probes,
and handles are used for spot checking through insulation inspection holes with our high-temperature
sensors. Lift-Assist devices are also available to be able to scan and dislodge Permanent Magnet probes
from a ferromagnetic part. The SH Sensor Positioning Fixture permits setting angles and distances to
facilitate setups in automated scanning.


Part
Number
Description Probes Picture
187A0001 4-Wheel Roller Kit for Permanent Magnet Probes
274A0106
274A0107
274A0144
274A0120
274A0121
274A0108

187A0002
Front-Rear Roller Kit for Medium Permanent Magnet
Probes
(used for axial scanning of tubes and rounds)
274A0106

187A0003
Front-Rear and Side Roller Kit for Large Permanent
Magnet Probes
(used for axial scanning of tubes and rounds)
274A0107
274A0144
274A0120
274A0121

187A0004
Front-Rear and Side Roller Kit for XL Permanent
Magnet Probes
(used for axial and circumferential scanning of tubes
and rounds)
274A0108
160A0063 Rail Head Roller Kit with Lift-Assist
2 x
274A0108

187A0007
High-Temperature Sensor Handle
1 D x 12 L
25mm D x 300mm L
274A0145
274A0146

160A0071
SH Sensor Positioning Fixture with Built-In Scales for
Angle (Yaw) and Distance to Pivoting Point
274A0133




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 162 of 163 InnerspecTechnologies
10.5. Encoders and Thermocouples

Designed to be integrated seamlessly with the instruments.

Part
Number
Description Connector Instrument
281A0002 Encoder Lemo FGG.2G.318 temate PowerBox H
281A0001 Thermocouple Type K Mini temate PowerBox H

10.6. Transport Cases
The temate

PowerBox transport cases are watertight, crushproof and dust proof with easy open double
throw latches. Automatic pressure equalization valve for air transport and wheels and handle for easy
transportation.

Part
Number
Description Dimensions Good For Picture
135V0001
Transport
Case Small

21.37" L x
16.31" W x
12.56" D
21.37" L x 16.31" W x 12.56" D
(54.3 x 41.4 x 31.9 cm)
1 x PowerBox 1, 2, 8,
MP
+ Accessories

135V0002
Transport
Case Large

31.50"L x
22.88"W x
18.88"D
31.50"L x 22.88"W x 18.88"D
(80.0 x 58.1 x 47.9 cm)
2 x PowerBox 1, 2, 8 MP
+ Accessories




Standard Sensors & Accessories for EMAT Applications
T-SA-E10 Page 163 of 163 InnerspecTechnologies
11. Limited Warranty

Innerspec Technologies warrants these products to be free of defects in Material and Workmanship for a
period of one year from date of purchase by end user. Innerspec Technologies will, at its choice, replace
or repair parts found defective and return equipment or parts to the purchaser.

The above stated warranty does not apply to products which have failed due to misuse, alteration,
unauthorized repair or modification. The purchaser is responsible for transportation costs of the equipment
to and from the factory for warranty replacement or repair. The above warranty does not include incidental
or consequential damages.

Das könnte Ihnen auch gefallen