The company Giordano Riello, founder and chairman of Aermec, assisted by his son Alessandro and daughter Raffaella,

has solidly associated the Company name with precise values: Respect for the environment by using new eco-friendly refrigerants as well as innovative installations using water as the carrier fluid. Noise pollution control with low-noise emission products, which undergo scrupulous testing before being put on the market. Energy saving, the great challenge of the Third Millennium, with the development of combined heating and air conditioning systems where appliances are used only as and when necessary. Health care special filters trap the smallest particles in suspension and the Plasmacluster system cleans the air of dust mites and moulds, making for a cleaner, healthier environment and with the new germicidal lamps eliminating all virus and batteries.

Hystory
1961 Giordano Riello sets up Riello Condizionatori, initially producing for contractors only. The story begins. 1963 The Aermec brand is born and marks all future company products designed and manufactured on site. The brand name gains a stronghold as a major product name in Italy and throughout Europe. 1970 Aermec can already supply fresh and warm air. Aermec presents the first dual section conditioner: the first split-system. Fancoil production starts. 1980 The Eighties sees the development of water chillers and air handling units. 1990 The Nineties mark the definitive consolidation of the company on the market. The Aermec brand is associated with advanced technology and high quality design. 1998 The name makes the company. From 1 January Aermec becomes the company name as well as product brand. 2000 The company consolidated its leadership in the production of fancoils, and laid the technological and production basis for strong growth in the field of high powered air-conditioning systems. 2002 Design and technology: Aermec launched Omnia a new generation of fancoils, designed for domestic applications. OMNIA is the result of co operation with a worldwide prestigious designer. 2004 The international market ask for number and Aermec answer. Giordano Riello make the producing system more technogical. High producing, quality and assistance: the success of Aermec is going to continue. 2006 Aermec consolidated its presence in world markets with system appliances. A series of models to meet all design engineering requirements. 2008 Aermec responds with more and more efficient units to the world challenge of energy saving with a special attention for our environment. 2010 Aermec extends the use of inverter technology on its fancoils and chillers. The perfect integration of the new inverter technology with the most sophisticated control systems is best expressed in the VMF (Variable Multi Flow) Hydronic System - anew way to interpret comfort in the home and elsewhere. 2011 Aermec turns 50. The company has developed and enlarged, always willing to understand and anticipate the needs of the market with innovative and quality products. Quality in innovation, in products, in pre-sales and after-sales services. Promotion of the philosophy of integrated design between designer and architect. Past success represents the commitment to the future.

1 AIR HANDLING UNITS FOR SYSTEMS


FAN COILS
FCX.................................................................................................................................... 12 Universal and vertical installations FCXI................................................................................................................................... 16 Fan coils with Inverter brushless motor Continuous 0-100% air flow rate regulation Universal, floor and ducted installation FCX P................................................................................................................................. 20 Ductable installations DUALJET............................................................................................................................ 24 Controlled outlet fan coils - Floor installation VEC.................................................................................................................................... 26 Installation in suspended ceilings Omnia HL.......................................................................................................................... 28 Universal installations for residential applications Omnia UL.......................................................................................................................... 30 Universal installations for residential applications Ventilcassaforma................................................................................................................ 32 Template for recessed installation of fancoils in the wall FCW................................................................................................................................... 34 Wall installation FCL..................................................................................................................................... 36 False ceiling installation and cooling power from 1900 to 11000W FCLI................................................................................................................................... 40 False ceiling installation and cooling power from 1900 to 4980W FHX.................................................................................................................................... 44 With germicidal lamp VED.................................................................................................................................... 48 Air handling terminal with cooling capacities from 0.99 to 5.82 kW VED.................................................................................................................................... 52 Air handling terminal with cooling capacities from 8 to 18 kW Control panels.................................................................................................................... 56 Variable Multi Flow Sistems............................................................................................... 58

THERMOCONVECTORS

Climafon............................................................................................................................ 62 Vertical installation residential use CLIMABOX........................................................................................................................ 64 Recessed wall-mounted convection heater

AIR CONDITIONING UNITS

2 HEAT RECOVERY UNIT

TUN................................................................................................................................... 66 Ductable air-conditioning unit TS....................................................................................................................................... 70 Air treatment unit with power from 4.85 to 24.8 kW TDA................................................................................................................................... 72 Air flow rate from 800 to 3,500 cu.m/h TA...................................................................................................................................... 74 Conditioning unit cooling efficiency with 4 row battery from 4.5 to 32 kW 5.5 a 40 kW 6 row coil - heating efficiency with 4 row battery from 14.0 to 78.0 kW 15.5 a 87.5 kW 6 row coil TN...................................................................................................................................... 78 Air conditioning unit - Air flow from 2300 to 23000 m3/h

RePuro............................................................................................................................... 84 Heat recovery unit TRS..................................................................................................................................... 86 Heat recovery unit with enthalpic heat exchanger UR...................................................................................................................................... 88 Heating recovery unit HRS.................................................................................................................................... 92 Heat recovery unit URX_CF............................................................................................................................. 96 Heat recovery unit with refrigerant circuit URHE_CF......................................................................................................................... 100 High efficiency heat recovery unit with refrigerant circuit without an external unit ERS................................................................................................................................... 104 Heat recovery unit high efficiency with static recovery ERSR................................................................................................................................. 108 Heat recovery unit with high efficiency rotary heat exchanger

UNITS FOR SYSTEMS

AIR-COOLED CHILLERS, HEAT PUMPS AND MOTOCONDENSING UNITS

ANL020-202.................................................................................................................... 114 Air cooled water chillers, heat pumps and condensing units Cooling capacity from 5,65 43,70 kW - Heating capacity from 5,65 43,70 kW ANL290-650.................................................................................................................... 118 Air cooled chillers with axial fans - Cooling capacity from 55 to 133 kW ANLH290-650.................................................................................................................. 122 Air cooled heat pump with axial fans - Heating capacity from 61 to 142 kW ANLI................................................................................................................................ 126 Air cooled chiller and heat pump with axial fans - Cooling capacity 5.70 - 28.80 kW ANK................................................................................................................................. 130 Air cooled heat pump with axial fans - Cooling capacity from 6,82 to 29,92 kW HBI.................................................................................................................................. 134 Air cooled split system heat pump for heating, cooling and production of DHW DC Inverter Technology - Heat capacity from 8.5 kW to 16 kW CL.................................................................................................................................... 138 Air cooled chiller and heat pump with plug fan - Capacities from 5.82 to 40.34 kW SRA.................................................................................................................................. 142 Heat pumps only for hot water production systems, up to 65C and domestic hot water up to 50 C - Heating capacity from 10 up to 18 kW SRP................................................................................................................................... 146 High Temperature AIR/WATER Heat Pump only With PLUG FAN fans and heating capacity from 10 up to 19 kW SWP................................................................................................................................. 150 High temperature air cooled heat pumps for the production of domestic hot water NRL 280-700.................................................................................................................... 152 Air cooled chillers with axial fans - Cooling capacity from 53 kW to 162 kW NRL-H 280-700................................................................................................................ 156 Air-cooled heat pumps with axial fans - Heating capacity from 58 kW to 172 kW NRL 750-1800.................................................................................................................. 160 Air cooled chillers with axial fans - Cooling capacity from 173 kW to 467 kW NRL-H 750-1800.............................................................................................................. 164 Air cooled heat pumps with axial fans - Heating capacity from 203 to 526 kW NRL 2000-3600................................................................................................................ 168 Air cooled chiller with axial fans - Cooling capacity from 500 kW to 938 kW NRL-H 2000-3600............................................................................................................ 172 Air cooled heat pumps - Heating capacity from 588 up to 1050 kW NRP 200-750................................................................................................................... 176 Multipurpose air cooled units with axial fans NRP 800-1800................................................................................................................. 180 Multipurpose air cooled units with axial fans NRL Free Cooling 280-700............................................................................... 184 Free cooling - Cooling capacity from 58 kW up to 174 kW NRL Free-Cooling 750-1800............................................................................. 188 Free cooling - Cooling capacity from 177 kW to 452 kW NRL Free-Cooling 2000-3600........................................................................... 192 Free cooling - Cooling capacity from 446 kW to 904 kW NRC................................................................................................................................. 196 Air cooled chillers, heat pumps and condensing units with centrifugal fans Capacities from 46 to 263 kW NS.................................................................................................................................... 200 Air cooled chillers with axial fans and twin-rotor screw compressor Cooling capacity from 237 to 1595 kW NSH................................................................................................................................. 208 Air cooled heat pumps with axial fans and twin-rotor screw compressor Cooling capacity from 235 to 730 kW, heating capacity from 276 to 789 kW NS Free-Cooling............................................................................................................... 216 Air cooled chillers with axial fans and screw compressors Cooling capacity from 272 to 1554 kW - Free-cooling capacity from 280 to 1510 kW NS Free-Cooling HWT..................................................................................................... 220 Air cooled chillers with axial fans and screw compressors Cooling capacity from 251 to 1542 kW - Free-cooling capacity from 251 to 1542 kW NS Glycol Free................................................................................................................. 224 Air cooled chillers with axial fans and screw compressors Cooling capacity from 272 to 1554 kW - Free-cooling capacity from 213 to 1149 kW NS Glycol Free HWT....................................................................................................... 228 Air cooled chillers with axial fans Free-cooling capacity from 251 to 1542 kW - Screw compressor NSI................................................................................................................................... 232 Air cooled chillers - INVERTER screw compressors, axial fans Cooling capacity from 262 to 1249 kW TBX.................................................................................................................................. 236 Air cooled chillers with two-stage centrifugal compressor and axial fans Cooling capacity from 259 to 861 kW

INDEPENDENT SYSTEM

IDROBLOC...................................................................................................................... 240 With capacity from 3.5 up to 6.7 kW IDROBLOC C................................................................................................................... 242 With capacity from 3.5 up to 8.2 kW

3 UNITS FOR SYSTEMS

Venice.............................................................................................................................. 244 Water-cooled reversible heat pumps units - With capacities from 6,9 up to 9,7 kW WRL 025-160................................................................................................................... 246 Water-cooled chillers - Cooling capacity from 6,58 to 43,40 kW WRL 180-650................................................................................................................... 250 Reversible water-cooled chillers for the production of hot water up to 55 C Cooling capacity from 50 to 168 kW - Heating capacity from 53 to 187 kW WRL-H 025-160............................................................................................................... 254 Water cooled reversible heat pumps for the production of hot water up to 60 C Cooling capacity from 6 up to 40 kW - Heating capacity from 8 up to 48 kW WRL-H 180-650............................................................................................................... 258 Water cooled reversible heat pumps for the production of hot water up to 55 C Cooling capacity from 45 to 157 kW - Heating capacity from 53 to 184 kW VXT.................................................................................................................................. 262 Water cooled GEOTHERMAL reversible heat pump Heating, cooling and domestic hot water NXW................................................................................................................................ 266 Water cooled internal chiller and heat pump units with scroll compressors Cooling capacity from 106 kW to 385 kW - Heating capacity from 119 kW to 419 kW WSA................................................................................................................................. 270 Water cooled chillers and heat pumps with twin-rotor screw compressor Cooling capacity from 147 to 715 kW WSB................................................................................................................................. 274 Water cooled chillers and heat pumps with twin-rotor screw compressor Cooling capacity from 172 to 704 kW - Heating capacity from 184 to 741 kW WSH................................................................................................................................ 278 Water cooled reverse cycle heat pumps with twin-rotor screw compressor Cooling capacity from 166 to 668 kW - Heating capacity from 190 to 819 kW TW110............................................................................................................................. 282 Water cooled modular chiller with centrifugal compressor WF................................................................................................................................... 284 Water cooled chillers with twin-rotor screw compressor Cooling capacity from 630 to 1549 kW - Heating capacity from 678 to 1654 kW HWF................................................................................................................................ 288 Water cooled chillers with twin-rotor screw compressor Cooling capacity from 628 to 1524 kW - Heating capacity from 671 to 1615 kW

WATER-COOLED CHILLERS, HEAT PUMPS AND MOTOEVAPORATING UNITS

AIR HANDLING UNITS

NCS.................................................................................................................................. 292 NCD................................................................................................................................. 294 NCT H.............................................................................................................................. 296 SPL025_130..................................................................................................................... 298 Swimming Pool Lines. Air handling unit high efficiency for health centres. Air flow from 4.000 to 13.000 m3/h. SPL160-250...................................................................................................................... 302 Swimming Pool Lines. Air handling unit high efficiency for health centres. Air flow from 16.000 to 25.000 m3/h ENERGY........................................................................................................................... 306 Air handling unit for outside air with high energy efficiency

ROOFTOP

WATER-COOLED PACKAGED AIR CONDITIONERS

RTE 025-200.................................................................................................................... 310 ROOF-TOP cooling only and heat pump unit Cooling capacities from 11,3 up to 55,9 kW - Heating capacities from 11,5 up to 55,70 kW RTE 240-400.................................................................................................................... 314 ROOF-TOP cooling only and heat pump unit - Cooling capacities from 82,5 up to 152 kW standard version - Heating capacities from 77,5 up to 148 kW standard version RTE 480-800.................................................................................................................... 318 ROOF-TOP cooling only and heat pump unit - Cooling capacities from 150 up to 254 kW standard version - Heating capacities from 151 up to 266 kW standard version

MEC-W............................................................................................................................ 322 With radial fans and capacities from 11 up to 55 kW

COMPONENTS FOR AIR CONDITIONING SYSTEMS

SAP.................................................................................................................................. 324 Storage tank with capacity from 75 up to 3500 l TRA.................................................................................................................................. 328 Cooling towers with capacities from 49.53 up to 1084.88 kW REMOTE CONDENSERS.................................................................................................. 330 Remote condensers DRY COOLERS................................................................................................................ 338 Dry coolers DMP................................................................................................................................. 346 Recessed dehumidifier for floor systems

4 ROOM AIR CONDITIONERS


GREEN LINE
SI...................................................................................................................................... 350 Split system air conditioner and heat pump Wall mounted monosplit with capacity from 2.6 a 6.45kW - DC Inverter Technology - Air ioniser standard HWI serie 1...................................................................................................................... 352 Split system air conditioner and heat pump - Wall mounted monosplit with capacity from 2.6 to 6.45kW - DC Inverter Technology - Air ioniser standard HWI................................................................................................................................. 354 Split system air conditioners and heat pumps Wall installation with 2.5 to 6.45 kW power output with Inverter HW.................................................................................................................................. 356 Split system air conditioners and heat pumps Ductable installation with capacities from 2.6 up to 6.6 kW LCI................................................................................................................................... 358 Split system air conditioner and heat pump - Monosplit with capacity from 2.7 to 17kW DC Inverter Technology DXE.................................................................................................................................. 362 Heat pump with two air-cooled sections Ducted horizontal installation with power from 20 up to 39,5 kW MKM................................................................................................................................ 364 Multisplit system heat pump - Inverter MultiSplit System with capacity from 5 to 12kW Wall mounted unit with air ioniser standard MDW............................................................................................................................... 368 Multisplit heat pumps with heat recovery for hot domestic water production Variable refrigerant flow system (VRF) with inverter power input from 10 to 16 kW MVF/MDS........................................................................................................................ 372 Multisplit heat pumps with Variable Refrigerant Flow System (VRF) with capacities from 10 up to 60 kW

BLUE LINE

EWIH............................................................................................................................... 376 Wall installation with capacities from 2.6 up to 7.0 kW with Inverter and Plasmacluster filter EFI.................................................................................................................................... 378 Universal installation with capacities from 2,6 up to 7 kW with Inverter and Plasmacluster filter EXCI................................................................................................................................. 380 Split system air conditioners and heat pumps Ductable installation with capacitie from 2.6 up to 3.5 kW with Inverter EFSI.................................................................................................................................. 384 Floor installation with capacities from 2.5 up to 5 kW with Inverter and Plasmacluster filter MIH................................................................................................................................. 386 MultiSplit System with capacities from 5.2 up to 8.4 kW with Inverter

PORTABLE

PSD.................................................................................................................................. 390

DEHUMIDIFIER

Smuffo............................................................................................................................. 392

WATER COOLED CONDENSING UNIT

CWX................................................................................................................................ 394 Water cooled condensing unit Cooling only operation - Internal installation with capacity from 3.5 to 6.7 kW FW-R................................................................................................................................ 398 Water-cooled air conditioners with capacities from 2.9 up to 4.0 kW

NEW

FCX

Fan coils Universal and floor installation


White:

housing: RAL 9002 head and feet: RAL 7044

FCX APC ZX
Aermec participate in the EUROVENT program: FC / 2 / H, FC / 4 / H the products are present on the site www.eurovent-certification.com

Plasmacluster
FCX-U

PLASMACLUSTER ioniser filter Plasmacluster reduces pollutants by decomposing their molecules. By means of electrical discharges, "Plasmacluster" provokes the fission of the water molecules in the air, into positive and negative ions. These ions neutralise the molecules of the gas pollutants, thereby creating products that are normally found in the air anyway. The result is in the air: at last you'll be able to breathe clean, ionised air free of any bad smells.

Features
Available in 16 sizes and 8 versions: - Vertical installation: FCX-A: vertical free-standing with switch FCX-AS: vertical free-standing without switch. Compatible with the VMF system FCX-ACT: vertical free standing with electronic thermostat FCX-APC: (FCX 22, 24, 32, 34, 36, 42, 44, 50, 54, 56, 62, 64, 82, 84) vertical free-standing with electronic thermostat and Plasmacluster purifier FCX-B : front suction, without selector. Compatible with the VMF system - Vertical and horizontal installation: FCX-U : universal floor or wall/ceiling mounting. Adjustable air distribution grille, except for models 62, 64, 82, 84 and 102. Compatible with the VMF system FCX-UA : universal floor or wall/ceiling mounting. Grille with fixed fins. Compatible with the VMF system FCX-UE: universal floor or wall/ceiling mounting with direct expansion coil. Adjustable air distribution grille, except for models 62, 82 and 102. Automatic fan coil switch-off with closure of the air distribution grille Broad range of controls Metallic protective cabinet with rustproofing polyester paint Quiet operation Low loss of charge in the heat exchange batteries Versions with 3-row coil (FCX 17, 22, 32, 36, Electric motors with permanently inserted condensers 42, 50, 56, 62, 82 and 102) Versions with 4-row coil (FCX 24, 34, 44, 54, Ease of installation and maintenance Air filter easy to remove and clean 64, and 84) Extractable shrouds for easy, effective cleaning EUROVENT Certification Water connections can be reversed during 3-speed ventilating unit installation phase Full compliance with the accident prevention standards Rounded line

Electronic thermostat (FCX-ACT)


Automatic switch on / switch off
Thanks to the supply water temperature check, the microprocessor automatically switches the fan and any valve on or off (in standby) in both summer and winter.

Automatic fan speed change

Possibility of automatic fan speed change, to ensure the gradual modulation of the power output.

Quiet operation

Automatic season changeover

The absence of any electromechanical drives eliminates that typical ticking noise produced in certain conditions when the relays are triggered. This, together with extremely silent ventilation, means that Aermec fan coils guarantee excellent sound comfort as there are no sudden peaks of noise, even at low levels.

Thanks to a supply water temperature check, the panel automatically positions itself in winter or summer operation, automatically changing the temperature scale in the thermostat as well.

Other functions:

AUTOTEST function, winter anti-freeze check

12

Accessories
AMP: kit for the wall mounting installation of versions FCX U and UE. BC: Auxiliary condensate drip tray. Use the BC 5-6 tray accessory if horizontal, or BC 4 if vertical. BV: Single row hot water coil. Not available for 4-row versions or those with Plasmacluster. DSC4: Condensate drainage device for use when natural run-off is not possible. PC: Sheet metal panel to close rear of unit. RX: Armoured electric coil with safety thermostat. (Requires a thermostat with heater management). Not available for 4-row versions or those with Plasmacluster. SE: Manually operated fresh air intake louver. SIT 3 - 5: Thermostat Interface Cards. They allow the creation of a network of fan coils (max. 10) commanded by a central control panel (selector or thermostat). SIT3: commands the 3 fan speeds and must be installed on each fan coil of the network; receives the commands from the selector or the SIT5 card. Accessories FMT10(1) FMT21(1) KTLM(1) PTI(1) PX(1) PX2(1) PX2C6(1)**** PXBI(1) PXAI(1) PXAE(1) PXAR(1) TF1(1) TPF (1) WMT05(1) WMT06(1) WMT10(1) VMF-E4(2) VMF-E4D(2) VMF-E2(2) VMF-E0(2) VMF-E1(2) AMP* AMP20 BC* 4***** 5 6 117 122 132 142 162 17 18 22 23 32 33 42 43 62 17 22 32 42 52 62 15X 20X 30X 40X 80X 3 5 1X4L - 1X4R 2X4L - 2X4R 3X4L - 3X4R 41-4124** 42-4224** 43-4324** 44-4424** 45-4524** 1-124** 2-224** 3-324** 4-424** 5 6 17

22

24

SIT5: commands the 3 fan speeds and up to 2 valves (four pipes systems); sends the commands of the thermostat to the fan coils network. SW3: water temperature probe that gives the automatic season change feature to electronic thermostats supplied with water-side change over. SWA: SWA external probe accessory (length L = 6m). The probe detects the temperature of the ambient air if connected to the connector (A) of the panel FMT21; the ambient air temperature probe incorporated in the panel is automatically deactivated. Detects the temperature of the water in the system, for ventilation consent, if connected to the connector (W) of the FMT21 panel. Two SWA probes can be connected to the panel FMT21 simultaneously. VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper. For 3/4-row and 1-row coils (BV). Combine the SW3 probe with FCX ACT, too. Versions with 230V and 24V~50Hz power supply. FCX Fan Coil Size 32 34 36 42 44 50 54 56 62

VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 3/4-row and 1-row coils (BV). Combine the SW3 probe with FCX ACT, too. Versions with 230V and 24V~50Hz power supply. VCF_X4: The valve kits are designed for fan coil units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits totally separated. The kit consists of 2 valves of 3-way 4 port connection complete with electro-thermal actuators, insulating shells for the valves and associated hydraulic piping. VCF1X4L Valve kit for left hand connection fan coil units. VCF1X4R Valve kit for right hand connection fan coil units. Power supply: 230V ~ 50Hz. ZX: Feet for floor-standing installations for A-AS-ACT-APC models. Control panels(1) and VMF System(2): the characteristics are described on the appropriate card. Versions

64

82

84

BV DSC4*

PC

RX**

SE SIT SW3 SWA

VCF *****

*** *** *** *** *** *** *** *** *** *** *** *** *** ***

*** ***

VCFD ZX

*** ***

* = The DSC4 accessory is not compatible with AMP and BC4_5_6 accessories. The DSC4 accessory is compatible with the installation brackets AMP20. ** = 24 Volt.

*** = Only for the BV 1-row coil accessory. **** = PX2C6, PX2 panel in multiple 6-piece pack. ***** = The VCF valve and the BC4 tray cannot be installed together on a single fan coil.

AS-B-U-UA AS-B-U-UA AS-B-UA-U (62 - 102) AS-B-U-UA AS-B-U-UA AS-B-U-UA AS-B-U-UA AS-B-U-UA AS-B-U-UA AS-B-U-UA AS-B-U-UA AS-B-UA-U (62 - 102) AS-B-U-UA U-UA-UE U-UA-UE A-AS-ACT-APC-B-U-UA UE U-UA-UE U-UA-UE AS-B-U-UA AS-B-U-UA AS-B-U-UA AS-B-U-UA AS-B-U-UA A-AS-ACT-APC-B-U-UA-UE A-AS-ACT-APC-B-UA U-UE A-AS-ACT-APC-B-UA U-UE A-AS-ACT-APC-B-UA U-UE A-AS-ACT-APC-B-UA U-UE A-AS-ACT-B-U-UA-UE AS-B-U-UA AS-B-U-UA-UE AS-B-U-UA-UE AS-B-U-UA-UE AS-B-U-UA-UE AS-B-U-UA-UE A-AS-ACT-APC A-AS-ACT-APC A-AS-ACT-APC A-AS-ACT-APC A-AS-ACT-APC AS-B-U-UA-UE AS-B-U-UA-UE AS-B-U-UA AS-B-U-UA AS-B-U-UA AS-B-U-UA AS-B-U-UA AS-ACT-APC-B-U-UA AS-ACT-APC-B-U-UA AS-ACT-APC-B-U-UA AS-B-U-UA *** AS-B-U-UA AS-ACT-APC-B-U-UA AS-ACT-APC-B-U-UA AS-ACT-APC-B-U-UA *** AS-B-U-UA A-AS-ACT-APC A-AS-ACT-APC

102

13

Technical data
Mod. Heating capacity Heating capacity (water inlet 50C) Heating capacity (electric resistor) Water ow rate Water pressure drops Total cooling capacity Sensible cooling capacity Water ow rate Water pressure drops Air ow rate Number of fans Sound pressure Sound power Water content Max. motor power Max input current Max power. with electric heater Input current with electric heater Coil connections FCX W (max.) W (med.) W (min.) W (E) W l/h kPa W (max.) (E) W (med.) W (min.) W (max.) (E) W (med.) W (min.) l/h kPa (E) m3/h (max.) m3/h (med.) m3/h (min.) n. dB (A) (max.) dB (A) (med.) dB (A) (min.) dB (A) (max.)(E) dB (A) (med.)(E) dB (A) (min.)(E) l (W) (E) (A) (W) (A) (4R) (3R) (1R) 17 22 24 32 34 36 42 44 50 54 56 62 64 82 84 102 2490 3400 3950 4975 5850 6150 7400 8600 8620 10100 9650 12920 14300 15140 17100 17020 2070 2700 3200 4085 4850 5050 6415 6930 7530 8760 8430 10940 11500 13350 14420 15240 1610 1915 2200 3380 3850 4180 5115 5200 5420 6240 6060 8330 8500 10770 11200 12560 1360 2100 2320 3160 3550 3800 4240 5250 4900 6100 5380 6460 7810 7990 10400 9670 700 214 2,8 1000 890 720 830 710 540 172 2,6 200 160 110 1 36,5 29,5 22,5 45 38 31 0,58 35 0,16 735 3,2 1/2 1/2 950 292 6,3 1500 1330 1055 1240 1055 755 258 5,8 290 220 140 1 41,5 34,5 22,5 50 43 31 0,79 25 0,12 975 4,25 1/2 1/2 340 4 1730 1500 1150 1380 1140 828 297 3 290 220 140 1 42,5 37,5 26,5 51 46 35 1 33 0,25 3/4 1300 427 14,2 2210 2055 1570 1750 1540 1100 380 16,6 450 350 260 2 39,5 32,5 25,5 48 41 34 1,11 44 0,21 1344 5,86 1/2 1/2 503 8 2800 2450 2050 2130 1789 1441 482 9 450 350 260 2 39,5 32,5 27,5 48 41 36 1,5 44 0,45 3/4 1300 1650 529 15 2800 2600 1980 2200 1930 1380 482 28 450 350 260 2 39,5 32,5 25,5 48 41 34 636 14,1 3400 2800 2310 2760 2115 1635 585 14,3 600 460 330 2 42,5 35,5 28,5 51 44 37 1,48 44 57 0,21 0,28 740 21 4450 3780 2970 3300 2722 2079 765 19,2 600 460 330 2 46,5 41,5 32,5 55 50 41 1,9 57 0,51 3/4 1950 741 14,2 4190 3640 2840 3000 2750 2040 721 19,3 720 600 400 2 47,5 42,5 33,5 56 51 42 1,48 67 0,35 2017 8,83 3/4 1/2 869 22 4970 4770 3620 3540 3101 2281 855 25,9 720 600 400 2 47,5 44,5 35,5 56 53 44 1,9 67 0,36 3/4 1950 2200 830 40 4600 3990 3110 3550 3250 2410 791 38 720 600 400 2 47,5 42,5 33,5 56 51 42 1110 14,8 4860 4660 3950 3980 3510 2825 836 11,6 920 720 520 3 48,5 42,5 33,5 57 51 42 2,52 67 82 0,35 0,4 1230 22 6350 5520 4500 5030 4195 3330 1092 13 920 720 520 3 48,5 42,5 35,5 57 51 44 3,4 91 0,48 3/4 2200 1300 19,8 7420 5500 4710 5680 4250 3450 1276 13,5 1140 930 700 3 53,5 48,5 41,5 62 57 50 2,52 106 0,49 2306 10,06 3/4 1/2 1471 30 8600 7600 6270 5780 5016 4013 1479 22 1140 930 700 3 52,5 48,5 42,5 61 57 51 3,4 106 0,62 3/4 2200 1464 16,6 7620 7140 6270 5980 4984 4263 1311 19,2 1300 1120 900 3 57,5 52,5 47,5 66 61 56 2,52 131 0,58 2331 10,15 3/4 1/2

1344 1707 5,86 7,45 3/4 1/2 3/4 1/2

2017 2282 8,83 3/4 1/2 9,97 3/4 1/2

Power supply = 230V ~ 50Hz (E) = EUROVENT certificate performances Performance values refer to the following conditions: Level of sound pressure (A-weighted) measured in the room with volume V= 85m3; reverberation time t=0.5s; direction factor Q=2; distance r=2.5m. Cooling: - Room air temperature 27C D.B. ; 19C W.B. maximum speed: - water inlet temperature 7C; Dt water 5C. medium and minimum speed: - water inlet temperature 7C; - water flow rate as at maximum speed. Heating: room air temperature 20C D.B. maximum speed - water inlet temperature 70C; Dt water 10C. medium and minimum speed: - water inlet temperature 70C; - water flow rate as at maximum speed. Heating*: room air temperature 20C D.B. maximum speed - water inlet temperature 50C; - water flow rate as for cooling operation.

VERSION FCX A FCX AS FCX ACT FCX APC FCX B FCX U FCX UA FCX UE

17 17 17 17 17 17 -

22 22 22 22 22 22 22 22

24 24 24 24 24 24 24 -

32 32 32 32 32 32 32 32

34 34 34 34 34 34 34 -

36 36 36 36 36 36 36 -

42 42 42 42 42 42 42 42

AVAILABLE SIZES 44 50 44 50 44 50 44 50 44 44 44 50 50 50 50

54 54 54 54 54 54 54 -

56 56 56 56 56 56 56 -

62 62 62 62 62 62 62

64 64 64 64 64 64 -

82 82 82 82 82 82 82

84 84 84 84 84 84 -

102 102 102 102 102 102

14

Dimensions (mm)

FCX A FCX U 17 - 22 - 32 - 36 - 42 - 50 - 56 FCX AS FCX U 24 - 34 - 44 - 54 FCX ACT FCX UE 22 - 32 - 36 - 42 - 50 - 56 FCX APC

FCX B FCX UA 17 - 22 - 32 - 36 - 42 - 50 - 56 FCX UA 24 - 34 - 44 - 54 FCX U 62 - 82 - 102 FCX U 64 - 84 FCX UE 62 - 82 - 102

Mod FCX (A - AS - ACT - APC) Height with feet Width Feet height Rear height with feet Weight (without feet) Mod FCX (U - UE) Height Width Weight Mod FCX (UA) Height Width Weight Mod FCX (B) Height Width Weight

A B C F kg

17 563 640 105 88 13 17 520 640 13 17 490 640 13 17 490 640 13

22 / 24 563 750 105 88 15 22 / 24 520 750 15 22 / 24 490 750 15 22 / 24 490 750 15

32 / 34 / 36 563 980 105 88 20 32 / 34 / 36 520 980 20 32 / 34 / 36 490 980 20 32 / 34 / 36 490 980 20

42 / 44 563 1200 105 88 24 42 / 44 w520 1200 24 42 / 44 490 1200 24 42 / 44 490 1200 24

50 / 54 / 56 563 1200 105 88 24 50 / 54 / 56 520 1200 24 50 / 54 / 56 490 1200 24 50 / 54 / 56 490 1200 24

62 / 64 688 1320 125 108 34 62 / 64 590 1320 34

82 / 84 688 1320 125 108 34 82 / 84 590 1320 34

102 688 1320 125 108 34 102 590 1320 34

D B kg

D B kg

D B kg

62 / 64 590 1320 34

82 / 84 590 1320 34

102 590 1320 34

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Telephone 0442633111 - Telefax 044293730 www.aermec.com

15

Cod.: SFCXUY.16 / 1301

FCXI

Fan coils with Inverter brushless motor Continuous 0-100% air flow rate regulation Universal, floor and ducted installation
FCXI P

FCXI AS

Aermec participate in the EUROVENT program: FC / 2 / H the products are present on the site www.eurovent-certification.com

White: FCXI U

housing: RAL 9002 head and feet: RAL 7044

The future is Inverter FCXI is the Aermec range of fan coils with continuous 0-100% air flow rate variation and therefore continuous heating/ cooling capacity variation. Thanks to the Inverter technology, the FCXI continuously modifies the air flow rate, adapting it - moment by moment to the real needs in the room. This produces considerable advantages in terms of electric savings, comfort and noise reduction compared with a traditional on-off 3-speed fan coil.

ELECTRIC SAVINGS OF 50% COMPARED WITH A FAN COIL WITH TRADITIONAL 3-SPEED MOTOR VERY QUIET OPERATION TOTAL COMFORT: REDUCED TEMPERATURE AND HUMIDITY VARIATIONS IN THE AIR-CONDITIONED ROOMS
Air temperature in the air-conditioned room

Traditional fan coil with 3-speed motor FCXI Inverter with Brushless motor

Set point

Characteristics
Available in 5 sizes and 3 versions: Full compliance with the accident preven FCXI AS: with tall cabinet tion standards FCXI U: with universal cabinet for floor/ cei- Rounded line ling installation Metallic protective cabinet with rustproofing FCXI P: without cabinet for ceiling installation polyester paint Adjustable air distribution grille, for U ver Compatible with VMF System sions EUROVENT Certification Fan coil automatic power-off function with Fan unit with Brushless motor (continuous closure of the air delivery grille, for U ver0-100% speed variation) sions Quiet operation

Time (s)

Low loss of charge in the heat exchange batteries Configurable during the installation phase using dip switches - to obtain greater head at nominal delivery, for P versions Ease of installation and maintenance Air filter easy to remove and clean Extractable shrouds for easy, effective cleaning Water connections can be reversed during installation phase

16

Brushless electric motor

The "brushless" electric motor is the result of combining the most sophisticated technologies from the fields of mechanics and electronics. "Brushless" literally means "without brushes". The brushless electric motor has no sliding contacts between the rotor and the stator. In brushless motors, the rotor consists of permanent magnets whose magnetic field interacts - without any mechanical contact - with the stator windings. With the special inverter device, it is possible to control the speed and torque of the rotor continuously, just by means of the stator currents. Compared with the traditional alternate current motors, the brushless motor offers huge advantages: - reduced wear and tear - the possibility to adjust the rotation speed accurately and continuously (0-100%) - higher energy yields - longer life and greater reliability

These characteristics have made the brushless motor irreplaceable in a wide variety of applications: - robotics - automotive - precision drives - CD/DVD players - medical equipment - etc. Thanks to Aermec's FCXI range of inverter fan coils, brushless technology can now make inroads in the field of chilled water air conditioning, bringing notable energy savings along with the precise contro of both air temperature and humidity in the air-conditioned rooms.

Accessories
Compulsory accessory, essential for unit operation: WMT20: Control panel with electronic thermostat and LCD monitor. Essential for operation. Wall mounting. VMF System : the characteristics are described on the appropriate card. Accessories: AMP: Kit for ceiling installation, for versions FCXI P and FCXI U. BC: Auxiliary condensate drip tray. BV: 1-row hot water coil. The accessory is not available for the 4R models. CHF: VentilCassaforma is a galvanised metal template that allows you to create a space directly in the wall for housing the fan coil. The template facilitates masonry work during the construction of the niche where the fan coil will be installed. When the work is finished, the fan coil will be completely hidden from sight. (For FCXI P only). DSC4: Condensate drainage device for use when natural run-off is not possible. GA: Intake grille with fixed fins. GAF: Intake grille with fixed fins and filter. GM: Delivery grille with adjustable fins. MA: A-type covering cabinet (use tray accessory BC 4 for FCXI AS). MU: U-type covering cabinet (use tray accessory BC 5-6 for FCXI U). PA: Plenum suction assembly in galvanised sheet metal, complete with suction couplings for circular-section ducts. PA-F : Plenum suction assembly that allows intake and delivery on the same side; suitable for all installations where the machine needs to be positioned outside the air-conditioned rooms in order to minimise noise levels and facilitate maintenance operations. PC: Sheet metal panel to close rear of unit. PM : Delivery plenum in galvanised sheet metal, externally insulated, complete with plastic delivery couplings for circular section ducts. RD: Straight delivery coupling for canalisation. RDA: Straight suction coupling for canalisation. RP: 90 delivery coupling for canalisation. RPA: 90 suction coupling for canalisation. SE: External air damper with command FCXI P and FCXI AS. SWI: Water temperature probe for WMT20 control panels. Cable length L = 2m. VCF: Kit comprising motorized 3 way valve with isolating shell, unions and insulated copper pipes. For 3/4-row and 1-row coils (BV). Versions with 230V and 24V~50Hz power supply. VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 3/4-row and 1-row coils (BV). VCF_X4: The valve kits are designed for fan coil units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits totally separated. The kit consists of 2 valves of 3-way 4 port connection complete with electrothermal actuators, insulating shells for the valves and associated hydraulic piping. VCF1X4L Valve kit for left hand connection fan coil units. VCF1X4R Valve kit for right hand connection fan coil units. Power supply: 230V ~ 50Hz. ZX: Feet for floor installations for FCXI AS models.

17

Accessories
WMT20 AMP* AMP20 BC*

20

30

FCXI fancoil Size 40


50

80

Versions
AS - U - P U-P U-P AS - (P+MA) U - (P+MU) U - (P+MU) P P AS - U - P AS - U - P AS - U - P AS - U - P P P P P AS - U - P P P P P P P P P P P P P P P P P P P P P P P P P P P P P AS U AS U AS U AS - U P P P P P P P P P P P P P P P P P P P P P P AS - P AS - P AS - P AS - P AS - U - P AS - U - P AS - U - P AS - U - P AS - U - P AS - U - P AS - U - P AS - U - P AS - U - P AS - U - P AS - U - P AS - U - P AS - U - P AS AS P P

BV

CHF DSC4* GA

4**** 5 6 8 9 122 132 142 162 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 22F 32F 42F 62F 22 23 32 33 42 43 62 1 2 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 20X 30X 40X 80X 1X4L - 1X4R 2X4L - 2X4R 3X4L - 3X4R 41 - 4124** 42 - 4224** 43 - 4324** 44 - 4424** 45 - 4524** 1 - 124*** 2 - 224*** 3 - 324*** 4 - 424*** 5 6 7 8

*** *** *** *** *** ***

GAF

GM

MA

MU

PA

PA

PC

*** *** *** ***

PCR PM

RD

RDA

RP

RPA

SE SWI

VCF ****

VCFD

ZX

* = The DSC4 accessory is not compatible with AMP and BC4_5_6_8_9 accessories. The DSC4 accessory is compatible with AMP20 accessory.

18

** = 24 Volt. *** = Only for accessory coil BV 1R. **** = The BC4 accessory is not available for models fitted with VCF valve.

Technical data
Mod. Heating capacity (inlet water 70C) Heating capacity (inlet water 50C) (E) Water ow rate Water pressure drops Total cooling capacity Sensible cooling capacity Water ow rate Water pressure drops Air ow rate Number of fans Sound pressure Sound power Water content Input power Input current Input power** (Maximum head) Input current** (Maximum head) Heat exchanger water connections Power supply = 230V ~ 50Hz (E) = Eurovent certified performance Performance values refer to the following conditions: Level of sound pressure (A-weighted) measured in the room with volume V = 85m3; reverberation time t = 0.5s; direction factor Q = 2; distance r = 2.5m ** FCXI P version with internal dip-switch setting to obtain the maximum head at nominal delivery. Cooling: - room air temperature 27C D.B. ; 19C W.B. - inlet water temperature 7C ; maximum speed - Dt water 5C Heating: room air temperature 20C D.B. maximum speed: - water inlet temperature 70C ; Dt water 10C Heating*: room air temperature 20C D.B. maximum speed - water inlet temperature 50C - water flow rate as for cooling operation FCXI W (max.) W (S.min.) W (max.) W (S.min.) l/h kPa W (max.) W (S.min.) W (max.) W (S.min.) l/h kPa m3/h (max.) m3/h (S.min.) n. dB(A) Vel. max dB(A) Vel. med dB(A) Vel. min dB(A) Vel. S.min dB(A) (max.) dB(A) (S.min.) l W (max.) A (max.) W (max.) A (max.) Gas 20 3400 1080 2100 670 292 6,3 1500 520 1240 370 258 5,8 290 70 1 41,5 34,5 22,5 21,5 50 30 0,79 12 0,11 36 0,33 1/2 30 4975 1410 3160 900 427 14,2 2210 690 1750 500 380 16,6 450 115 2 39,5 32,5 25,5 18.5 48 28 1,11 12 0,11 45 0,41 1/2 40 7400 1700 4240 980 636 14,1 3400 760 2760 550 585 14,3 600 140 2 42,5 35,5 28,5 21,5 51 30 1,48 16 0,14 57 0,5 3/4 50 8620 1830 4900 1040 741 14,2 4190 800 3000 536 721 19,3 720 140 2 47,5 42,5 33,5 21,5 56 30 1,48 37 0,3 62 0,51 3/4 80 15140 2740 7990 1450 1300 19,8 7420 1170 5680 830 1276 13,5 1140 190 3 53,5 48,5 41,5 23,5 62 32 2,52 75 0,57 102 0,78 3/4

Dimensions (mm)

FCXI AS

FCXI 20P - 30P - 40P - 50P

FCXI 20U - 30U - 40U - 50U

FCXI 80U

FCXI 80P

Mod FCXI Height Width Weight

D E kg

20 U 520 750 15

30 U 520 980 20

40 U 520 1200 24

50 U 520 1200 24

80 U 590 1320 34

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

19

Cod.: SFCXIUY.02 / 1303

Mod FCXI Height with feet Width Height of feet Rear height with feet Weight (without feet)

20 AS 30 AS 40 AS 50 AS 80 AS A 563 563 563 563 688 B 750 980 1200 1200 1320 C 105 105 105 105 125 F 88 88 88 88 108 kg 15 20 24 24 34

FCXI A B C D E F G H L M N Weight (kg)

20P 453 562 216 440 41 101 74 260 144 49 522 13

30P 453 793 216 671 41 101 74 260 144 49 753 18

40P 453 1013 216 891 41 101 74 260 144 49 973 22

50P 453 1013 216 891 41 101 74 260 144 49 973 22

80P 558 1147 216 1102 41 107 68 273 253 32 1122 33

NEW

FCX P
Aermec participate in the EUROVENT program: FC / 2 / H, FC / 4 / H the products are present on the site www.eurovent-certification.com

Fan coils Duct installation

Plasmacluster
- Vertical installation: FCX PV: wall-mounted model without cabinet Versions with 3-row coil (FCX 17, 22, 32, 36, 42, 50, 56, 62, 82, 102) Versions with 4-row coil (FCX 24, 34, 44, 54, 64, and 84) EUROVENT Certification 3-speed ventilating unit Full compliance with the accident prevention standards Compatible with the VMF system Wide range of controls and accessories Quiet operation Low loss of charge in batteries Electric motors with permanently inserted condensers Ease of installation and maintenance Air filter easy to remove and clean Possibility of a residual head for ducting (if required) Internal insulation and air filter in fire resistance class 1 Extractable shrouds for easy, effective cleaning Water connections can be reversed during installation phase

Features
Available in 16 sizes and 5 versions: - Vertical and horizontal installation: FCX P: wall-mounted model without cabinet FCX PPC: (FCX 22, 32, 36, 42, 50, 56, 62, 64 , 82, 84) wall/ceiling mounting without cabinet, with Plasmacluster purifier. Compatible with the VMF system, or you can request a combination with the PXAE control panel FCX PE: wall-mounted model without cabinet and with direct expansion coil FCX PO: cabinet with 6-speed (3 of which can be selected) boosted motor (FCX 22, 32, 36, 42, 50, 56, 62, 64 , 82, 84)

Accessories
AMP: Kit for overhang installation. BC: Auxiliary condensate drip tray. BV: 1-row hot water coil. Not available for 4-row versions or those with Plasmacluster. CHF: VentilCassaforma is a galvanised metal template that allows you to create a space directly in the wall for housing the fan coil. The template facilitates masonry work during the construction of the niche where the fan coil will be installed. When the work is finished, the fan coil will be completely hidden from sight. (For FCX P - PV only). DSC4: Condensate drainage device for use when natural run-off is not possible. GA: Intake grille with fixed fins. GAF: Intake grille with fixed fins and filter. GM: Delivery grille with adjustable fins. MA: A-type covering cabinet (use tray accessory BC 4 for FCX AS). MU: U-type covering cabinet (use the BC 5-6 tray accessory if horizontal, or BC 4 if vertical). PCR: Galvanised plate protection for the controls and the electrical element. PA: Plenum suction assembly in galvanised sheet metal, complete with suction couplings for circular-section ducts. PA-F: Plenum suction assembly that allows intake and delivery on the same side; suitable for all installations where the machine needs to be positioned outside the air-conditioned rooms in order to minimise noise levels and
Accessories FMT10(1) FMT21(1) KTLP(1) PX(1) PX2(1) PX2C6(1)***** PXAE(1) PXAR(1) TF1(1) TPF(1) WMT05(1) WMT06(1) WMT10 (1) VMF-E4(2) VMF-E4D(2) VMF-E0(2) VMF-E1(2) AMP* AMP20 4***** 5 BC* 6 8 9 117 122 BV 132 142 162 17

facilitate maintenance operations. PM: Delivery plenum in galvanised sheet metal, externally insulated, complete with plastic delivery couplings for circular section ducts. RD: Straight delivery coupling for canalisation. RDA: Straight suction coupling for canalisation. RP: 90 delivery coupling for canalisation. RPA: 90 suction coupling for canalisation. RX: Armoured electric coil with safety thermostat. (Requires a thermostat with heater management). Not available for 4-row versions or those with Plasmacluster. SE: Manually operated fresh air intake louver. SIT 3 - 5: Thermostat Interface Cards. They allow the creation of a network of fan coils (max. 10) commanded by a central control panel (selector or thermostat). SIT3: commands the 3 fan speeds and must be installed on each fan coil of the network; receives the commands from the selector or the SIT5 card. SIT5: commands the 3 fan speeds and up to 2 valves (four pipes systems); sends the commands of the thermostat to the fan coils network. SW: water temperature probe that gives the automatic season change feature to electronic thermostats supplied with water-side change over. SWA: SWA external probe accessory (length L = 6m). The probe detects the temperature of the ambient air if connected to the connector (A) of the panel FMT21; the ambient air temperature
32

probe incorporated in the panel is automatically deactivated. Detects the water temperature in the system for ventilation consent, if connected to the connector (W) of the FMT21 panel. Two SWA probes can be connected to the panel FMT21 simultaneously. VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper. For 4-row, 3-row and 1-row coils (BV). Versions with 230V and 24V~50Hz power supply. VCFD : Kit consisting of powered 2-way valve, copper couplings and pipes. For 4-row, 3-row and 1-row coils (BV). Versions with 230V and 24V~50Hz power supply. VCF_X4: The valve kits are designed for fan coil units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits totally separated. The kit consists of 2 valves of 3-way 4 port connection complete with electro-thermal actuators, insulating shells for the valves and associated hydraulic piping. VCF1X4L Valve kit for left hand connection fan coil units. VCF1X4R Valve kit for right hand connection fan coil units. Power supply: 230V ~ 50Hz. ZX: Feet for recessed installation. Control panels(1) and VMF System(2): the characteristics are described on the appropriate card.
62

22

24

34

36

FCX Fan Coil 42 44


50

54

56

64

82

84

102 Versions P-PE-PO-PV P-PE-PO-PV P-PE-PO-PV P-PE-PO-PV-PPC P-PE-PO-PV P-PE-PO-PV P-PE-PO-PV P-PE-PO-PV

P-PE-PO-PV P-PE-PO-PPC P-PE-PO-PPC FCX P-PV+ MA FCX P + MU FCX P + MU P-PE-PO-PPC P-PE-PO-PPC P-PE-PV P-PE-PO-PV P-PE-PO-PV P-PE-PO-PV P-PE-PO-PV

20

Accessories CHF DSC4* GA

17 22 32 42 62 17 22 32 42 62 17 22 32 42 62 17 22 32 42 62 17 22 32 42 62 17 22 32 42 62 17 22 32 42 62 17 F 22 F 32 F 42 F 62 F 1 2 17 22 32 42 62 17 22 32 42 62 17 22 32 42 62 17 22 32 42 62 17 22 32 42 62 17 22 32 42 52 62 15X 20X 30X 40X 80X 3 5 1X4L - 1X4R 2X4L - 2X4R 3X4L - 3X4R 41 - 4124** 42 - 4224** 43 - 4324** 44 - 4424** 45 - 4524** 1 - 124** 2 - 224** 3 - 324** 4 - 424** 7 8

17

22

24

32

34

36

FCX Fan Coil 42 44

50

54

56

62

64

82

84

GAF

GM

MA

MU

PA

PA PCR PM

RD

RDA

RP

RPA

RX

*** *** *** *** *** *** *** *** *** *** *** ***

SE SIT SW3 SWA

*** *** ***

VCF *****

VCFD ZX

*** *** ***

102 Versions P-PV P-PV P-PV P-PV P-PV P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PPC P-PE-PV P-PE-PO-PV P-PE-PO-PV P-PE-PO-PV P-PE-PO-PV P-PE-PO-PV P-PE-PV P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV-PPC P-PE-PO-PV P-PE-PO-PV-PPC P-PO-PV P-PO-PV P-PO-PV P-PO-PV P-PO-PV P-PO-PV-PPC P-PO-PV-PPC P-PO-PV-PPC P-PO-PV *** P-PO-PV P-PO-PV-PPC P-PO-PV-PPC P-PO-PV-PPC *** P-PO-PV P-PE-PO-PV-PPC P-PE-PO-PV-PPC

* = The DSC4 accessory is not compatible with AMP and BC4_5_6_8_9 accessory. The DSC4 accessory is compatible with the installation brackets AMP20. ** = 24 Volt. *** = Only for the BV1-row coil accessory.

**** = PX2C6, PX2 panel in multiple 6-piece pack. ***** = The VCF valve and the BC4 tray cannot be installed together on a single fan coil.

21

Technical data
Mod. Heating capacity Heating capacity* (water inlet 50C) Heating capacity (electric resistor) Water ow rate Water pressure drops Total cooling capacity FCX W (max.) W (med.) W (min.) W (E) W 17 2490 2070 1610 1360 700 22 3400 2700 1915 2100 950 292 6,3 1500 1330 1055 1240 1055 755 258 5,8 290 220 140 1 41,5 34,5 22,5 49,5 58 50 43 31 0,79 25 54 0,12 0,25 975 1004 4,25 4,38 1/2 1/2 24 3950 3200 2200 2320 340 4 1730 1500 1150 1380 1140 828 297 3 290 220 140 1 42,5 37,5 26,5 49,5 58 51 46 35 1 33 54 0,25 0,25 3/4 32 4975 4085 3380 3160 1300 427 14,2 2210 2055 1570 1750 1540 1100 380 16,6 450 350 260 2 39,5 32,5 25,5 44 52,5 48 41 34 1,11 44 97 0,21 0,45 1344 1397 5,86 6 1/2 1/2 34 5850 4850 3850 3550 503 8 2800 2450 2050 2130 1789 1441 482 9 450 350 260 2 39,5 32,5 27,5 44 52,5 48 41 36 1,5 44 97 0,45 0,45 3/4 36 6150 5050 4180 3800 1300 529 15 2800 2600 1980 2200 1930 1380 482 28 450 350 260 2 39,5 32,5 25,5 44 52,5 48 41 34 1,11 44 97 0,21 0,45 1344 1397 5,86 6 3/4 1/2 42 7400 6415 5115 4240 1650 636 14,1 3400 2800 2310 2760 2115 1635 585 14,3 600 460 330 2 42,5 35,5 28,5 50 58,5 51 44 37 1,48 57 111 0,28 0,51 1707 1761 7,45 7,68 3/4 1/2 44 8600 6930 5200 5250 740 21 4450 3780 2970 3300 2722 2079 765 19,2 600 460 330 2 46,5 41,5 32,5 50 58,5 55 50 41 1,9 57 111 0,51 0,51 3/4 50 54 56 62 64 82 84 102 8620 10100 9650 12920 14300 15140 17100 17020 7530 8760 8430 10940 11500 13350 14420 15240 5420 6240 6060 8330 8500 10770 11200 12560 4900 1950 741 14,2 4190 3640 2840 3000 2750 2040 721 19,3 720 600 400 2 47,5 42,5 33,5 50,5 59 56 51 42 1,48 67 82 0,35 0,36 2017 2032 8,83 8,84 3/4 1/2 6100 869 22 4970 4770 3620 3540 3101 2281 855 25,9 720 600 400 2 47,5 44,5 35,5 50,5 59 56 53 44 1,9 67 82 0,36 0,36 3/4 5380 1950 6460 2200 7810 7990 10400 9670 2200 2200

Sensible cooling capacity Water ow rate Water pressure drops Air ow rate Number of fans Sound pressure Sound pressure FCX PO Sound power FCX PO Sound power Water content Max. motor power (W) Max input current (A) Max. motor power (W) with electric heater Max input current (A) with electric heater Coil connections

l/h 214 kPa 2,8 1000 W (max.) (E) W (med.) 890 W (min.) 720 830 W (max.) (E) W (med.) 710 W (min.) 540 l/h 172 2,6 kPa (E) m3/h (max.) 200 m3/h (med.) 160 m3/h (min.) 110 n. 1 dB (A) (max.) 36,5 dB (A) (med.) 29,5 dB (A) (min.) 22,5 dB (A) (max.) dB (A) (max.) 45 dB (A) (max.)(E) dB (A) (med.)(E) 38 31 dB (A) (min.)(E) l 0,58 35 FCXP (E) FCXPO FCXP 0,16 FCXPO FCXP 735 FCXPO FCXP 3,2 FCXPO (4R) (3R) 1/2 (1R) 1/2

830 1110 40 14,8 4600 4860 3990 4660 3110 3950 3550 3980 3250 3510 2410 2825 791 836 38 11,6 720 920 600 720 400 520 2 3 47,5 48,5 42,5 42,5 33,5 33,5 50,5 53,5 59 62 56 57 51 51 42 42 1,48 2,52 67 82 82 97 0,35 0,4 0,36 0,48 2017 2282 2032 2297 8,83 9,97 8,84 10,05 3/4 3/4 1/2 1/2

1230 1300 22 19,8 6350 7420 5520 5500 4500 4710 5030 5680 4195 4250 3330 3450 1092 1276 13 13,5 920 1140 720 930 520 700 3 3 48,5 53,5 42,5 48,5 35,5 41,5 53,5 55,5 62 64 57 62 51 57 44 50 3,4 2,52 91 106 97 135 0,48 0,49 0,48 0,62 2306 2335 10,06 10,19 3/4 3/4 1/2

1471 1464 30 16,6 8600 7620 7600 7140 6270 6270 5780 5980 5016 4984 4013 4263 1479 1311 22 19,2 1140 1300 930 1120 700 900 3 3 52,5 57,5 48,5 52,5 42,5 47,5 55,5 64 61 66 57 61 51 56 3,4 2,52 106 131 135 0,62 0,58 0,62 2331 10,15 3/4 3/4 1/2

Power supply = 230V ~ 50Hz (E) = EUROVENT certificate performances Performance values refer to the following conditions: Level of sound pressure (A-weighted) measured in the room with volume V=85m3; reverberation time t=0.5s ; direction factor Q=2 ; distance r=2.5m Cooling: - Room air temperature 27C D.B. ; 19C W.B. - Water inlet temperature 7C ; Maximum speed - Dt water 5C - For medium and low speed, the water flow rate remains the same as at maximum speed Heating 70: room air temperature 20C D.B. Maximum speed - Water inlet temperature 70C ; Dt water 10C Medium and minimum speed: - Water inlet temperature 70C - Water flow rate as at maximum speed. Heating 50: Room air temperature 20C D.B. Maximum speed - Water inlet temperature 50C - Water flow rate as for cooling operation

VERSION FCX P FCX PV FCX PO FCX PE FCX PPC

17 17 -

22 22 22 22 22

24 24 24 24

32 32 32 32 32

34 34 34 34

36 36 36 36

42 42 42 42 42

AVAILABLE SIZES 44 50 44 50 44 50 50 44 50

54 54 54 54

56 56 56 56

62 62 62 62 62

64 64 64 64

82 82 82 82 82

84 84 84 84

102 102 102 -

22

Dimensions (mm)
FCX 17 - 22 / 24 - 32 / 34 / 36 - 42 / 44 - 50 / 54 / 56 FCX 62 / 64 - 82 / 84 - 102

FCX A B C D E F G H L M N Weight [Kg]

17 453 452 216 330 41 101 74 260 144 49 412 11

22 / 24 453 562 216 440 41 101 74 260 144 49 522 13

32 / 34 / 36 453 793 216 671 41 101 74 260 144 49 753 18

42 / 44 453 1013 216 891 41 101 74 260 144 49 973 22

50 / 54 / 56 453 1013 216 891 41 101 74 260 144 49 973 22

62 / 64 558 1147 216 1102 41 107 68 273 253 32 1122 33

82 / 84 558 1147 216 1102 41 107 68 273 253 32 1122 33

102 558 1147 216 1102 41 107 68 273 253 32 1122 33

PA - INTAKE PLENUM

PM - DELIVERY PLENUM

PA A Vents

17 390 1

22 500 2

32 731 2

42 951 3

62 1072 4

PM A Vents

17 412 1

22 522 2

32 753 2

42 973 3

62 1094 4

PA-F - FRONT INTAKE PLENUM PM PA-F

L Vents

B* = Closed inlet vent, to use it remove the push-out closing component.

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Telephone 0442633111 - Telefax 044293730 www.aermec.com

23

Cod.: SFCXPUY.13 / 1303

PA 17 F 658 1 [A]

PA 22 F PA 32 F PA 42 F PA 62 F 768 1039 1259 1381 1 [A] 2 [A+B*] 2 [A+B*] 2 [A+B]

NEW

DUALJET

Controlled outlet fan coils Floor installation


White:

housing: RAL 9002 head and feet: RAL 7044

DUALJET: comfort, everywhere The perception of uneven temperature distribution, especially vertically, is one of the main factors that can drastically reduce occupants' perceived well-being. The innovative DUALJET fan coil makes the room more comfortable, by directing the air in such a way as to provide uniform temperature distribution throughout the room. In winter, warm air is directed towards the floor; in the summer, cool air is directed towards the ceiling.

Features
Controlled outlet fan coils available in 4 Front outlet for heating operation. sizes: Outlet from the top for cooling operation. Versions with 3-row coil - Vertical installation: DUALJET : without control panel but with (sizes 20, 30, 40, 50) VMF-E0 thermostat, ready for installation on 3-speed ventilating unit the network as a Slave unit or as a single or Full compliance with the accident prevention standards Master unit if combined with the wired panel accessories VMF-E4 / VMF-E4D or VMF-E2D Rounded line Metallic protective cabinet with rustproofing control panel. polyester paint All units are compatible with the VMF system Switching the front air outlet or from the top, Plastic feet available as accessory Quiet operation using the selector on the unit. Low loss of charge in the heat exchange batteries Electric motors with permanently inserted condensers Ease of installation and maintenance Air filter easy to remove and clean Extractable shrouds for easy, effective cleaning Water connections can be reversed during installation phase

Fan coil with controlled outlet


Comfort, anywhere
Optimum air flow in the room, depending on functioning mode. In every season the air temperature in the room will be uniform at all heights avoiding annoying stratification phenomena. In winter operation the hot air flow is directed towards the floor, in summer operation the cold air flow is directed towards the ceiling. The user can decide at any time through which air outlet the air flow is directed.

VMF:

Quiet operation

Its extremely silent ventilation means that Aermec fan coils guarantee excellent sound comfort as there are no sudden peaks of noise, even at low levels.

All DUALJET fan coils are equipped with VMF ( Va r i a b l e M u l t i F l ow ) t h e r m o s t a t , t h e management and control system of hydronic systems for the conditioning, heating and production of domestic hot water. The VMF system allows complete control of every component of a hydronic system both locally and centrally and, communicating between the various components of the system, manages the performance without ever neglecting the end user's request of comfort, but reaching it as efficiently as possible with energy saving. Summing up the advantages of this innovative control with the flexibility of a hydronic system, a more effective and efficient alternative to the variable refrigerant flow systems (VRF) is obtained. The VMF system is extremely flexible, enough to allow various control and manage steps, expandable at different moments.

24

Technical data
DUALJET Heating capacity Heating capacity* (inlet water 50C) Water ow rate Water pressure drop Total cooling capacity Sensible cooling capacity Water ow rate Water pressure drop Air ow rate Number of fans Sound pressure Sound power Water content Max. motor power Max. input current Coil connections W (max.) W (med.) W (min.) W l/h kPa W (max.) W (med.) W (min.) W (max.) W (med.) W (min.) l/h kPa m3/h (max.) m3/h (med.) m3/h (min.) No. dB (A) (max.) dB (A) (med.) dB (A) (min.) dB (A) (max.) dB (A) (med.) dB (A) (min.) L (W) (A) (3R) 20 3400 2700 1915 2100 292 6.3 1500 1330 1055 1240 1055 755 258 5.8 290 220 140 1 41.5 34.5 22.5 50 43 31 0.79 25 0.12 1/2 30 4975 4085 3380 3160 427 14.2 2210 2055 1570 1750 1540 1100 380 16.6 450 350 260 2 39.5 32.5 25.5 48 41 34 1.11 44 0.21 1/2 40 7400 6415 5115 4240 636 14.1 3400 2800 2310 2760 2115 1635 585 14.3 600 460 330 2 42.5 35.5 28.5 51 44 37 1.48 57 0.28 3/4 50 8620 7530 5420 4900 741 14.2 4190 3640 2840 3000 2750 2040 721 19.3 720 600 400 2 47.5 42.5 33.5 56 51 42 1.48 67 0.35 3/4

Power supply = 230V~ 50Hz Performance values refer to the following conditions: Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; direction factor Q = 2; distance r = 2.5m; Cooling: room air temperature 27C D.B. ; 19C W.B. maximum speed: - water inlet temperature 7C ; t water 5C medium and minimum speed: - water inlet temperature 7C - water flow rate as at maximum speed

Heating: room air temperature 20C D.B. maximum speed - water inlet temperature 70C ; t water 10C medium and minimum speed: - water inlet temperature 70C - water flow rate as at maximum speed Heating*: room air temperature 20C D.B. maximum speed - water inlet temperature 50C - water flow rate as for cooling operation

Accessories
Control panel and VMF System (1): The featu24V~50Hz power supply. res are described in the dedicated cards. VCF_X4: The valve kits are designed for fan coil * VMF-E1D Please contact us. units with single coil, installed in a 4 pipe ZX: Feet for floor mounting system with the "Cooling" and "Heating" circuits VCF: the kit contains a motorised 3-way valve totally separated. The kit consists of 2 valves of with insulating shell, plus coupling and pipes 3-way 4 port connection complete with electroin insulated copper. For 4-row, 3-row and thermal actuators, insulating shells for the val1-row coils (BV). Versions with 230V and ves and associated hydraulic piping. VCF1X4L 24V~50Hz power supply. Valve kit for left hand connection fan coil units. VCFD: Kit consisting of powered 2-way valve, VCF1X4R Valve kit for right hand connection copper couplings and pipes. For 4-row, 3-row fan coil units. Power supply: 230V ~ 50Hz. and 1-row coils (BV). Versions with 230V and
C 220 220

DUALJET VMF-E4(1) VMF-E4D(1) VMF-E2D(1) VMF-E1D(1) ZX5 VCF41 VCF4124 VCF42 VCF4224 VCFD1 VCFD124 VCFD2 VCFD224 VCF1X4L VCF1X4R VCF2X4L VCF2X4R

20 *

30 *

40 *

50 *

Dimensions (mm)

C 220

DUALJET20 - DUALJET30
C 220

DUALJET40 + ZX5 DUALJET50 + ZX5

DUALJET40 - DUALJET50

DUALJET20 + ZX5 DUALJET30 + ZX5 Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

DUALJET Height Height with feet Length Height of feet Rear height with feet Weight (without feet)

A B C D E kg

20 520 563 750 105 88 15

30 520 563 980 105 88 20

40 520 563 1200 105 88 24

50 520 563 1200 105 88 24

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

25

Code: SDJUY.01 / 1301

VEC
Aermec participate in the EUROVENT program: FC / 2 / H the products are present on the site www.eurovent-certification.com

Cassette type fancoil Coanda-effect Installation in false ceilingsInstallation in false ceilings

Features
VEC : Fan coil for ambient air treatment during the summer. The air is delivered into the room via vents which, thanks to the COANDA effect, make the air jet adhere to the ceiling. Available in 4 sizes Installation in false ceilings Compatible with VMF System Grille with suction and adjustable delivery vents with Coanda effect (compulsory accessory). 3-row coil Reduced pressure drops across heat exchangers For systems with fixed and variable delivery EUROVENT certified 3-speed fan unit Quiet operation Motors with permanently connected condensers Air filter easily removed and cleaned Internal insulation and air filter of Class 1 fire resistance Removable shrouds for easy, effective cleaning Reversibility of the water connections during installation Broad range of controls and accessories Easy installation and maintenance Full compliance with safety regulations For possible heat mode functioning, refer to the technical manual notes.

Accessoires
Compulsory accessories: SIT 3-5 : thermostat interface cards. These FMT21; in this case the ambient air tempera the following are essential for the functioallow you to create a network of fan coils ture probe built into the panel will be autoning of the units: (max. 10), commanded from a centralised matically disabled. Detects the temperature VEC_GL: air suction and delivery grille with panel (selector or thermostat). of the water in the system to allow ventilation adjustable Coanda-effect vents. SIT3: commands the 3 fan speeds, and must consent if connected to the connector (W) of White RAL 9010. be installed on each fan coil in the network; the panel FMT21. Two SWA probes may be Control panel and VMF system: the features receives the commands from the selector or simultaneously connected to the panel of the control panels are described in the SIT5 card. FMT21. relevant card. SIT5: commands the 3 fan speeds and up to 2 VCF : kit consisting of a 3-way motorised valves (4-pipe systems); conveys the thermovalve, and copper couplings and pipes. For Accessories: stat commands to the fan coil network. 3-row and 1-row coils (BV). Versions with AMP: kit for wall-mounting installation. SW3: water temperature probe, allowing the 230V and 24V~50Hz power supply. BC5: auxiliary condensate drain tray. implementation of automatic season chan- VCFD: Kit consisting of a 2-way motorised BV: Single row hot water coil. geover for those electronic thermostats equipvalve, and copper couplings and pipes. For DSC4: condensate drainage device for use ped with water side changeover. 3-row and 1-row coils (BV). Versions with when natural run-off is not possible. SWA: SWA external probe accessory (length L 230V and 24V~50Hz power supply. PCR1: galvanised sheet metal protection for = 6m). Detects the ambient air temperature if the commands and the electric resistor. connected to the connector (A) of the panel Accessory VEC20GL VEC30GL VEC40GL FMT10 FMT21 KTLP PX2 PXAE PXAR WMT05 WMT10 20 30 VEC 40 50 Accessory AMP ** AMP 20 BC 5 ** 122 BV 132 142 DSC 4 ** SIT 3 SIT 5 PCR1 20 30 VEC 40 50 Accessory SW 3 SWA 41 42 44* VCF 4124 4224 4424* 1 2 4* VCFD 124 224 424* 20 30 VEC 40 50

* = only for accessory coil BV 1R ** = DSC4 The accessory is not compatible with the installation brackets AMP and with the basins BC5.

26

Technical data
Mod. VEC Total cooling capacity W (max) W (med) W (min) W (max) W (med) W (min) l/h kPa m3/h (max) m3/h (med) m3/h (min) n. dB (A) (max) dB (A) (med) dB (A) (min) dB (A) (max) dB (A) (med) dB (A) (min) l W A W A 20 1320 1085 805 1085 885 640 227 4,6 247 194 130 1 39,5 33,5 26,5 48,0 42,0 35,0 0,79 25 0,12 975 4,25 1/2"G 1/2"G 30 1950 1645 1370 1535 1285 1055 335 13,3 383 309 241 2 36,5 31,5 26,5 45,0 40,0 35,0 1,11 44 0,21 1344 5,86 1/2"G 1/2"G 40 2985 2470 1985 2410 1980 1580 514 11,3 511 406 306 2 40,0 34,5 29,5 48,5 43,0 38,0 1,48 57 0,28 1707 7,45 3/4"G 1/2"G 50 3610 3170 2350 2595 2275 1680 621 14,8 613 529 371 2 44,5 41,5 34,5 53,0 50,0 43,0 1,48 67 0,35 2017 8,83 3/4"G 1/2"G

Sensible cooling capacity Water ow rate Water pressure drops Air ow rate Number of fans Sound pressure Sound power Water content Max. motor power Max. input current Max. power with electric resistor (RX) Input current with electric resistor 3-row coil connections 1-row coil connections (BV)

Heating mode: see notes and warnings in the technical booklet.


Electricity supply = 230V ~ 50Hz (E) = EUROVENT certificate performance Performance values refer to the following conditions: Level of sound pressure (A-weighted) measured in the room with volume V=85m3 ; reverberation time t=0.5 s ; direction factor Q=2 ; distance r=2.5 m Cooling: - room air temperature 27C D.B. ; 19C W.B. - inlet water temperature 7C - Dt water 5C

Dimensions (mm)
VEC20GL VEC30GL VEC40GL

62

595

595

595

15

15

895

1195

57

Mod. A Weight (VEC) Weight (VEC GL)

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

27

Cod.: SVECUY.03 / 1302

277

VEC VEC mm kg kg

020 20GL 574 15,5 3,7

030 30GL 874 20,6 5,7

040 40GL 1174 24,7 7

050 40GL 1174 24,7 7

595

Omnia HL
Aermec participate in the EUROVENT program: FC / 2 / H the products are present on the site www.eurovent-certification.com

Fan coils Universal installations for residential applications

White colour:

cover: RAL 9002 top and supports: RAL 7044 cover: FIAT 656 top and supports: RAL 7031

(only for Omnia HL PC and PCM)

Plasmacluster
HL LM: grey cabinet with Self-Closing Louver and electronic thermostat HL PC: white body with electronic thermostat and Plasmacluster filter (factory-mounted only) HL PCM: metallic grey body with electronic thermostat and Plasmacluster filter (factorymounted only) HL S: white body with no on-board controls VMF System compatible HL SM: metallic grey body with no on-board controls. VMF System compatible 3-speed centrifugal fan Very quiet operation

Grey colour:

Features
HL (High Line) fan coils for both horizontal and vertical installation 4 sizes and 12 versions: HL: white body with switch HL M: metallic grey body with switch HL C: white body with electronic thermostat HL CM: metallic grey body with electronic thermostat HL N: white body with electronic thermostat VMF HL NM: metallic grey body with electronic thermostat VMF HL L: white cabinet with Self-Closing Louver and electronic thermostat Aesthetically styled with soft flowing lines New adjustable air delivery louver Automatic power-off function with closure of the air delivery louver Slim dimensions Electronic temperature control, automatic fan speed change, automatic season changeover and automatic on - off (with electronic thermostat) Water connections reversibility during installation Low pressure drop across heat exchanger Motors with permanently connected condensers Easy installation and maintenance Full compliance with safety regulations

Accessories
AMP: Kit for wall/ceiling mounting. Standard on S and SM versions. BC: Auxiliary condensate drip tray. BC 10 for vertical installation BC 20 for horizontal installation DSC5: Condensate drainage device for use when natural run-off is not possible. DSC5 is not compatible BC10 - BC20 accessories. PCH - PCHM : Back closing panel, white (PCHM) or gray (PCHM). SIT 3-5 : Thermostat interface cards. They allow to set up a fancoils network (max. 10) commanded by a centralised panel (switch or thermostat). SIT3: commands the three speeds of the fan and must be installed on each fancoil of the network; it receives the commands from the switch or from the SIT5 card. SIT5: commands the 3 fan speeds and up to two valves (four-pipe systems); it sends the thermostat commands to the fancoils network. SW: Water probe which enables automatic season change-over thanks to the specific electronic thermostats. SWA: External probe accessory SWA (length L=6m). It detects the temperature of the room air if connected to the connector (A) of the FMT21 panel. The room air temperature probe, incorporated in the panel, is automatically disabled. It detects the temperature of the water in the system for ventilation consent if connected to the connector (W) of the FMT21 panel. Two SWA probes can be connected simultaneously to the FMT21 panel. VCH: Kit comprising motorized 3-way valve, unions and copper pipes. VCHD : Kit comprising motorized 2-way valve, unions and copper pipes. ZH1: White feet for floor-standing installations ZH1B: White feet for floor-standing installations with skirting board. ZH1M: Gray feet for floor-standing installations ZH1MB: Gray feet for floor-standing installations with skirting board. Control panels (1) and VMF system (2) : the characteristics of the control panels are described on the appropriate card.
Compatibility of accessories Omnia HL 11 16 26 36 Versions FMT10(1)FMT21(1) S-SM PX2(1) PX2C6(1) S-SM PXAE(1) S-SM TPF(1) S-SM (1) (1) WMT05 WMT10 S-SM VMF-E4(2) VMF-E4D(2) S-SM VMF-E2H(2) S-SM VMF-E0(2) VMF-E1(2) S-SM AMP 10 All except S, SM BC10 * All BC20 * All DSC5 * All PCH/PCHM All SIT3 S-SM SIT5 S-SM SW3 S-SM SWA S-SM VCH All except L, LM VCHD All except L, LM ZH1/ZH1B All ZH1M/ZH1MB All
PX2C6, PX2 panel in multiple 6-piece pack. * = The DSC5 accessory is not compatible BC10 - BC20 accessories.

Main features
Versions compatible with VMF System. Precharged electrostatic filter: Omnia fan ecules present in the air to separate into posi Fan cleaning : Omnia fan coils allow fan coils have, as standard, precharged electrotive and negative ions. These ions neutralise blades to be easily cleaned. It is now possible static filters. These filters, thanks to their spethe gas pollutant molecules, forming products to remove the fan volute (it contains the fan cial execution, attracts and retains all susthat are normally present in clean air. The blades) and clean it periodically. pended dust particles, thus garanteeing pure result is in the air: you can finally breath Condensate drip tray cleaning: Thanks to a breathable air to the whole family. clean, odour-free ionised air. new drip tray fitting, it is now easier to clean P L A S M A C L U S T E R i o n i s i n g f i l t e r : Silent operation: Thanks to the use of special it with Omnia fan coils. This important soluPlasmacluster is capable of reducing the level centrifugal fans, Omnia fan coils operation is tion avoids, in the long run, bacteria, germs of pollutants, by decomposing the molecules extremely silent and offers the maximum and mould to grow up, in the drip tray that form them. Using a series of electric acoustic comfort. because of the air humidity. shocks, "Plasmacluster" causes the water mol-

28

Technical data
Mod. Omnia Heating capacity Heating capacity (water inlet 50C)* Water ow rate Water pressure drop Total cooling capacity W (max.) W (med.) W (min.) W (E) l/h kPa W (max.) (E) W (med.) W (min.) W (max.) (E) W (med.) W (min.) l/h kPa (E) m3/h (max.) m3/h (med.) m3/h (min.) n. dB (A) (max.) dB (A) (med.) dB (A) (min.) dB (A) (max.) (E) dB (A) (med.) (E) dB (A) (min.) (E) l W (E) A HL 11 2010 1460 1060 1150 173 1,6 840 650 490 700 530 390 144 1,9 180 120 80 1 37,5 28,5 22,5 46,0 37,0 31,0 0,4 18 0,09 1/2 HL 16 2910 2120 1540 1700 250 3,7 1200 950 690 990 750 520 206 4,8 240 160 110 1 39,5 34,5 25,5 48,0 43,0 34,0 0,5 32 0,15 1/2 HL 26 4620 3830 2890 2750 397 10,5 2030 1780 1420 1640 1370 1050 349 11,0 350 270 190 2 39,5 34,5 26,5 48,0 43,0 35,0 0,8 35 0,18 1/2 HL 36 5940 4870 3530 3540 511 7,4 2830 2310 1730 2040 1790 1280 487 9,5 460 350 240 2 39,5 32,5 25,5 48,0 41,0 34,0 1,1 42 0,22 1/2

Sensible cooling capacity Water ow rate Water pressure drop Air ow rate Fans Sound pressure Sound power Water contents Max. motor power Max. input current Coil connections Power supply = 230V ~ 50Hz (E) = Eurovent certified performance

Performance values refer to the following conditions: Level of sound pressure (A-weighted) measured in the room with volume V=85m3; reverberation time t=0.5s ; direction factor Q=2; distance r=2.5m Cooling: - room air temperature 27C D.B. ; 19C W.B. - water inlet temperature 7C ; maximum speed - Dt water 5C - for medium and low speed, water flow rate remains same as at maximum speed

Heating: - room air temperature 20C - water inlet temperature 70C ; maximum speed - Dt water 10C - for medium and low speed, water flow rate remains same as at maximum speed Heating*: - room air temperature 20C - water inlet temperature 50C - maximum speed - water flow same as in cooling operation

Dimensions (mm)

Mod Omnia Height Width Depth Height Weight

A B C D [kg]

HL 11 600 640 187 93 13,6

HL 16 605 750 189 93 14,6

HL 26 615 980 191 93 17,6

HL 36 623 1200 198 93 20,6

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

29

Cod.: SOHLUY.15 / 1301

Omnia UL
Aermec participate in the EUROVENT program: FC / 2 / H the products are present on the site www.eurovent-certification.com

Fan coils Universal installations for residential applications

Omnia UL-P

Plasmacluster
(only for Omnia UL PC)

White colour:
Omnia UL

cover: RAL 9002 top and supports: RAL 7044

Features
UL (Universal Line) fan coils for both horizontal and vertical installation 4 sizes and 5 versions: UL-S: version without switch, with cabinet. Compatible with VMF System UL: version with switch and cabinet UL-C: version with electronic thermostat and with cabinet UL-PC : version with electronic thermostat and Plasmacluster filter (factory-mounted only) and cabinet UL-P: ceiling mounting version without cabinet. Compatible with VMF System EUROVENT certified 3-speed centrifugal fan Very quiet operation Aesthetically styled with soft flowing lines Adjustable air delivery louver Automatic power-off function with closure of the air delivery louver Slim dimensions Electronic temperature control, automatic fan speed change, automatic season changeover and automatic on - off (with electronic thermostat) Water connections reversibility during installation Low pressure drop across heat exchanger Motors with permanently connected condensers Easy installation and maintenance Air filter easy to remove and to clean Full compliance with safety regulations

Accessories
AMP: Kit for wall/ceiling mounting. Standard on P and S versions. BC: Auxiliary condensate drip tray. BC 10 for vertical installation BC 20 for horizontal installation DSC5: Condensate drainage device for use when natural run-off is not possible. DSC5 is not compatible BC10 - BC20 accessories. GU: Aspiration grille, covers the front space between the stands, does not interfere with the air filter. Use with ZU stands compulsory. PCU: Rear cover panel. SIT 3-5 : Thermostat interface cards. They allow to set up a fancoils network (max. 10) commanded by a centralised panel (switch or thermostat). SIT3: commands the three speeds of the fan and must be installed on each fancoil of the network; it receives the commands from the switch or from the SIT5 card. SIT5: commands the 3 fan speeds and up to two valves (four-pipe systems); it sends the thermostat commands to the fancoils network. SW : Water probe wich enables automatic season change-over thanks to the specific electronic thermostats. SWA: External probe accessory SWA (length L = 6m). It detects the temperature of the room air if connected to the connector (A) of the FMT21 panel. The room air temperature probe, incorporated in the panel, is automatically disabled. It detects the temperature of the water in the system for ventilation consent if connected to the connector (W) of the FMT21 panel. Two SWA probes can be connected simultaneously to the FMT21 panel. VCH: Kit comprising motorized 3-way valve, unions and copper pipes. VCHD : Kit comprising motorized 2-way valve, unions and copper pipes. ZU: Feet for floor-standing solutions. Control panels (1) and VMF System (2): The control panels are described in a separate document.
Compatibility of accessories Omnia UL FMT10(1)FMT21(1) PX2(1) PX2C6(1) PXAE(1) PXLM(1) TPF(1) WMT05(1) WMT10(1) VMF-E4(2) VMF-E4D(2) VMF-E0(2) VMF-E1(2) AMP10 BC10 * BC20 * DSC5 * GU PCU SIT3 SIT5 SW3 SWA VCH VCHD ZU 11 10 10 16 15 15 26 25 25 36 35 35 Versions S-P S-P S-P S S-P S-P S-P S-P UL-C-PC All All All UL-S-C-PC UL-S-C-PC S-P S-P All S-P All All UL-S-C-PC

Main features

PX2C6, PX2 panel in multiple 6-piece pack. * = The DSC5 accessory is not compatible BC10 - BC20 accessories.

Versions compatible with VMF System. Precharged electrostatic filter: Omnia fan ecules present in the air to separate into posi Fan cleaning : Omnia fan coils allow fan coils have, as standard, precharged electrotive and negative ions. These ions neutralise blades to be easily cleaned. It is now possible static filters. These filters, thanks to their spethe gas pollutant molecules, forming products to remove the fan volute (it contains the fan cial execution, attracts and retains all susthat are normally present in clean air. The blades) and clean it periodically. pended dust particles, thus garanteeing pure result is in the air: you can finally breath Condensate drip tray cleaning: Thanks to a breathable air to the whole family. clean, odour-free ionised air. new drip tray fitting, it is now easier to clean P L A S M A C L U S T E R i o n i s i n g f i l t e r : Silent operation: Thanks to the use of special it with Omnia fan coils. This important soluPlasmacluster is capable of reducing the level centrifugal fans, Omnia fan coils operation is tion avoids, in the long run, bacteria, germs of pollutants, by decomposing the molecules extremely silent and offers the maximum and mould to grow up, in the drip tray that form them. Using a series of electric acoustic comfort. because of the air humidity. shocks, "Plasmacluster" causes the water mol-

30

Technical data
Mod. Omnia Heating capacity Heating capacity (water inlet 50C)* Water ow rate Water pressure drop Total cooling capacity W (max.) W (med.) W (min.) W (E) l/h kPa W (max.) (E) W (med.) W (min.) W (max.) (E) W (med.) W (min.) l/h kPa (E) m3/h (max.) m3/h (med.) m3/h (min.) n. dB (A) (max.) dB (A) (med.) dB (A) (min.) dB (A) (max.) (E) dB (A) (med.) (E) dB (A) (min.) (E) l W (E) A UL 11 2010 1460 1060 1150 173 1,6 840 650 490 700 530 390 144 1,9 180 120 80 1 37,5 28,5 22,5 46 37 31 0,4 18 0,09 1/2 UL 16 2910 2120 1540 1700 250 3,7 1200 950 690 990 750 520 206 4,8 240 160 110 1 39,5 34,5 25,5 48 43 34 0,5 32 0,15 1/2 UL 26 4620 3830 2890 2750 397 10,5 2030 1780 1420 1640 1370 1050 349 11 350 270 190 2 39,5 34,5 26,5 48 43 35 0,8 35 0,18 1/2 UL 36 5940 4870 3530 3540 511 7,4 2830 2310 1730 2040 1790 1280 487 9,5 460 350 240 2 39,5 32,5 25,5 48 41 34 1,1 42 0,22 1/2

Sensible cooling capacity Water ow rate Water pressure drop Air ow rate Fans Sound pressure Sound power Water contents Max. motor power Max. input current Coil connections Power supply = 230V ~ 50Hz. (E) = Eurovent certified performance

Performance values refer to the following conditions: Level of sound pressure (A-weighted) measured in the room with volume V = 85m3 ; reverberation time t = 0.5s ; direction factor Q = 2; distance r = 2.5m Cooling: - room air temperature 27C D.B. ; 19C W.B. - water inlet temperature 7C ; maximum speed - Dt water 5C - for medium and low speed, water flow rate remains same as at maximum speed

Heating: - room air temperature 20 C - water inlet temperature 70 C ; maximum speed - Dt water 10 C - for medium and low speed, water flow rate remains same as at maximum speed Heating*: - room air temperature 20 C - water inlet temperature 50 C - maximum speed - water flow same as in cooling operation
E F

Dimensions (mm)

Mod Omnia Height Width Depth Weight

A D B C E F G kg

UL 11 606 93 640 173 384 360,5 288 12,5

UL 16 606 93 750 173 494 470,5 398 13,5

UL 26 606 93 980 173 725 701,5 629 16,5

UL 36 606 93 1200 173 945 921,5 849 19,5

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

31

Cod.: SOULUY.15 / 1301

Ventilcassaforma
CHF CHU L

Template for recessed installation of fancoils in the wall

Ventilcassaforma has been designed to respond to the needs to rationalise spaces to suit modern interior architecture. Ventilcassaforma is a galvanised template that makes it possible to make a space to house fan coils in the wall. The template will make masonry work easier during the construction of a niche where the fan coil will be installed. When the work is finished, the fan coil will be completely hidden from view. Ventilcassaforma is available in two versions with the same characteristics but designed to house fan coils from two different series: - CHU-L for fan coils in the Omnia UL-P series - CHF for fan coils in the FCX-P , FCX-PV and FCXI-P series in 2 pipe systems, 2 pipe systems with resistance and with 4 pipe systems

Features
Available in two versions for combined grey with rough glazed finish in order to fan coils: hold the paint. The final colour can be CHU-L : Ventilcassaforma for the chosen by the client. OMNIA UL-P series. Available in four Closure Panel: Made of galvanised steel, sizes this is the box housing the fan coil. The CHF: Ventilcassaforma for FCX-P , FCX-PV box is recessed in the wall during builand FCXI-P fan coils. Available in 5 sizes ding work making the construction of a Compatible with VMF System niche where the fan coils will be instal Ventilcassaforma is made up of the folled much easier. Holes for fitting the fan lowing parts to be assembled: coil and preparing an electric plant with - Recess box; a socket and GEWISS fuse holder are - Closure panel; already present on the back panel. The - Outer frame with deflector; box can accommodate the hydraulic - Cover bases, cross-members, covers. system pipes and condensation drain All parts are made of galvanised steel pipes thanks to the presence of several and treated with epoxy-polyester resineasily-removable elements on the sides based thermo-hardening base paint in and base. Closure Panel: made of steel pre-treated with base paint and no slots present. Easily removable for servicing and cleaning the air filter. Outer Frame: the perimeter of the box has an outer frame made of pre-treated steel making it possible to cover the perimeter part of the wall and hide any imperfections that overtime show possible crumbling on the edge of the plaster work. Deflector: manual, with which the flow of air can be directed into the room. The deflector is incorporated in the frame.

32

Ventilcassaforma - Omnia UL combination


Ventilcassaforma Fan coil Ventilcassaforma CHU L + Omnia UL combination CHU 12 L CHU 17 L Omnia UL 11 P Omnia UL 16 P CHU 27 L Omnia UL 26 P CHU 37 L Omnia UL 36 P

Ventilcassaforma

CHF 17 FCX 17 P FCX 17 PV

Fan coil

Ventilcassaforma CHF + FCX P - FCX PV - FCXI P combination CHF 22 CHF 32 CHF 42 CHF 62 FCX 22 P FCX 32 P - 36 P FCX 42 P - 50 P - 56 P FCX 62 P - 82 P - 102 P FCX 22 PV FCX 32 PV - 36 PV FCX 42 PV - 50 PV - 56 PV FCX 62 PV - 82 PV - 102 PV FCX 24 P FCX 34 P FCX 44 P - 54 P FCX 64 P - 84 P FCX 24 PV FCX 34 PV FCX 44 PV - 54 PV FCX 64 PV - 84 PV FCXI 20 P FCXI 30 P FCXI 40 P - 50 P FCXI 80 P

The fan coils FCX-P , FCX-PV and FCXI-P can be inserted into 2 pipe systems, 2 pipe systems with resistance and 4 pipe systems

Dimensions (mm)
CHU Height Width Depth A A1 B B1 C 12 L 691 648 692 644 186 17 L 691 648 802 754 186 27 L 691 648 1032 984 186 37 L 691 648 1252 1204 186

CHF Height Width Depth A A1 B B1 C

17 728 684 732 684 240

22 728 684 842 794 240

32 728 684 1073 1025 240

42 728 684 1293 1245 240

62 833 789 1414 1366 240

Outer frame and closure panel CHU Height A A1 A2 A3 B B1 12 L 724 634 70 494 713 633 17 760 680 93 493 94 753 673 17 L 724 634 70 494 823 743 22 760 680 93 493 94 863 783 27 L 724 634 70 494 1053 973 32 760 680 93 493 94 1094 1014 37 L 724 634 70 494 1273 1193 42 760 680 93 493 94 1314 1234 62 865 785 93 598 94 1435 1355

Width

CHF A A1 A2 A3 A4 B B1

A4
Cod.: SVC2UY.06 / 1302

Height

Width

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

33

NEW

FCW
Aermec participate in the EUROVENT program: FC / 2 / H the products are present on the site www.eurovent-certification.com

Fan coil Wall installation

2V VERSION WITH 2-WAY VALVE FITTED INSIDE WIRED CONTROL PANEL OR REMOTE CONTROL 3V VERSION WITH 3-WAY VALVE FITTED INSIDE WIRED CONTROL PANEL OR REMOTE CONTROL VL VERSION WITHOUT VALVE WIRED CONTROL PANEL OR REMOTE CONTROL
Features

2VN VERSION WITH 2-WAY VALVE FITTED INSIDE STANDARD CONTROL OR VMF SYSTEM 3VN VERSION WITH 3-WAY VALVE FITTED INSIDE STANDARD CONTROL OR VMF SYSTEM VLN VERSION WITHOUT VALVE STANDARD CONTROL OR VMF SYSTEM

By choosing the appropriate options it is possible to select the model to suit the specific system requirements:

Unit configuration:
123 Code FCW 45 Size 21 31 41 67 Valve 2V (2-way valve fitted inside) 3V (3-way valve fitted inside) VL (without Valve) 8 Microprocessor Controller (Blank) with controller N without controller

EUROVENT certified Cream color Display on panel front Tangential three-speed fan assembly Very quiet operation Aesthetic design Horizontally adjustable discharge air blades Horizontal deflector blades to vertically adjust discharge air. Manually adjustable only for units

without microprocessor controller. For units with microprocessor controller adjustable only via PFW2 wired control panel or TLW2 remote control Timer for on/off programming (TLW2 and PFW2) Automatic, cooling, heating, ventilation and dehumidification function programming (TLW2 and PFW2) Sleep function only with TLW2 remote control

Automatic season change (TLW2 and PFW2) Automatic start after black-out (TLW2 and PFW2) Ease of installation with hydraulic and condensate drain connections adjustable in several directions Routine maintenance is limited to periodic cleaning of the air filter Air filter can be easily removed and cleaned Full compliance with safety regulations

Accessories
TLW2 REMOTE CONTROL (accessory for versions with microprocessor controller FCW_2V, FCW_3V, FCW_VL): Accessory essential for the fan coil unit operation, as an alternative to the PFW2 wired control panel. The two control systems cannot be used at the same time on the same fan coil unit. The TLW2 remote control is provided loose from the fan coil unit. One remote control can control several fan coil units. The remote control makes it possible to set all the operating parameters of the unit. These parameters are shown on a liquid crystal display making programming operations easier. The remote control is supplied with a bracket allowing it to be hung on the wall. The remote control is fitted with a support so it can be hung on the wall and it is therefore possible to carry out the required operations without removing it, it must be installed at a point on the wall that is easy to reach and not exposed to sources of heat, steam or direct sunlight and that is at least a meter from televisions or other electronic apparatus The remote control is powered by two 1.5V mini stick batteries of the R03 AAA type and works optimally up to seven meters from the unit. PFW2 WIRED CONTROL PANEL (accessory for versions with microprocessor controller FCW_2V, FCW_3V, FCW_VL): Accessory essential for the fan coil unit operation, as alternative to the TLW2 remote control. The two control systems cannot be used at the same time on the same fan coil unit. A PFW2 wired control panel can control just one fan coil unit. The wired control panel must be installed on the wall and connected to the fan coil unit with the cable provided loose. The panel cable is 4 metres long. The PFW2 makes it possible to set the main operating parameters of the unit. These parameters are shown on a liquid crystal display making programming operations easier. WIRED CONTROL PANELS and VMF System (Accessories essential for versions without microprocessor controller FCW_2VN, FCW_3VN, FCW_VLN): Accessories essential for the fan coil unit operation, which then requires a cable connected accessory panel or connection to the accessories of the VFM system. The characteristics of the control panels are described on the appropriate card.

34

Technical data
Mod. Heating capacity (E) FCW W (max.) W (med.) W (min.) kPa (max.) kPa (med.) kPa (min.) W (max.) W (med.) W (min.) W (max.) W (med.) W (min.) l/h (max.) l/h (med.) l/h (min.) kPa (max.) kPa (med.) kPa (min.) W (max.) Input power (E) W (med.) W (min.) A (max.) Input current A (med.) A (min.) m3/h (max.) Air ow rate m3/h (med.) m3/h (min.) dB (A) (max.) dB (A) (med.) dB (A) (min.) dB (A) (max.) dB (A) (med.) dB (A) (min.) 212V 2400 1800 1400 21 13 8 1900 1450 1100 1550 1200 920 327 249 189 23 14 9 27 24 23 0,13 0,11 0,1 380 330 270 44,5 39,5 34 53 48 42,5 F 213V 2400 1800 1400 21 13 8 1900 1450 1100 1550 1200 920 327 249 189 23 14 9 27 24 23 0,13 0,11 0,1 380 330 270 44,5 39,5 34 53 48 42,5 F 21VL 2560 2180 1700 8 6 4 2050 1740 1370 1735 1475 1160 352 299 236 9 7 5 27 24 23 0,13 0,11 0,10 389 340 280 44,5 39,5 34 53 48 42,5 F 312V 3000 2600 1940 26 20 12 2400 2080 1550 1970 1680 1280 413 358 267 29 22 13 27 23 22 0,13 0,11 0,11 440 390 320 44,5 39,5 34 53 48 42,5 F 313V 3000 2600 1940 26 20 12 2400 2080 1550 1970 1680 1280 413 358 267 29 22 13 27 23 22 0,13 0,11 0,11 440 31VL 3125 2690 2225 14 10 7 2500 2150 1780 2040 1825 1510 430 370 306 15 11 8 27 23 22 0,13 0,11 0,11 446 412V 4750 4310 3750 28 24 18 3800 3450 3000 2850 2500 2015 654 593 516 32 27 21 48 41 41 0,23 0,19 0,14 540 470 370 45,5 40,5 35,5 54 49 44 F 413V 4750 4310 3750 28 24 18 3800 3450 3000 2850 2500 2015 654 593 516 32 27 21 48 41 41 0,23 0,19 0,14 540 470 370 45,5 40,5 35,5 54 49 44 F 41VL 5100 4675 3840 23 19 14 4080 3740 3075 3475 3115 2595 702 643 529 26 21 15 48 41 31 0,23 0,19 0,14 684 602 476 45,5 40,5 35,5 54 49 44 F

Water pressure drop (E)

Cooling capacity (E)

Sensible cooling capacity (E)

Water ow rate

Water pressure drop (E)

Sound pressure Sound power (E) Coil connections Power supply (E) = EUROVENT certified performance

390 400 320 330 44,5 44,5 39,5 39,5 34 34 53 53 48 48 42,5 42,5 F F 230V ~ 50Hz

Level of sound pressure (A-weighted) measured in the room with volume V=85m3; reverberation time t=0.5s; direction factor Q=2; distance r=2.5m Performance values refer to the following conditions (EUROVENT 6/3) : Cooling: - Room air temperature 27C B.S. ; 19C B.U. - Water inlet temperature 7C - t water 5C Heating: - Room air temperature 20C B.S. - Water inlet temperature 50C - t water 5C - Water flow rate remains same as at cooling mode

Dimensions (mm)
C

TLW2 FCW Height Width Depth Weight A B C kg

PFW2 212V 212V 298 880 180 9 21Vl 312V 312V 305 990 180 10 31Vl

B
412V 412V 360 1172 210 19 41Vl

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

35

Cod.: SFCW3VUY.02/1209

FCL
Aermec participate in the EUROVENT program: FC / 2 / H, FC / 4 / H the products are present on the site www.eurovent-certification. com

Cassette type fancoil Ceiling and false ceiling installation, cooling power from 1900 up to 11000W
Models: FCL 32 , FCL36 , FCL42 , FCL62 - FCL72 FCL 34 , FCL38 , FCL44 , FCL64 Models: FCL 82 , FCL102 , FCL122 FCL 84 , FCL104 , FCL124
FCL with accessory FCLMC

GLL10 - GLL10M - GLL10R - GLL10N


White: RAL 9010

GLL20 - GLL20R - GLL20N


White: RAL 9010

FCLMC

White: RAL 9010

Remote Control included for GLL10M GLL10R - GLL20R

4 CONFIGURATIONS ON ONE CASSETTE-TYPE FAN COIL: - WITH MOTORISED LOUVERS THAT CAN BE ORIENTED VIA THE REMOTE CONTROL (GLL10M ONLY) - WITH LOUVERS THAT CAN BE ORIENTED MANUALLY, REMOTE CONTROL - WITH LOUVERS THAT CAN BE ORIENTATED MANUALLY, WALL-MOUNTED CONTROL PANEL - WITH MANUALLY ADJUSTABLE FINS, VMF SYSTEM ELECTRONIC THERMOSTAT, WALL-MOUNTED CONTROL PANEL (VMF-E4), COMPLETE INTEGRATION WITH THE VMF SYSTEM (ONLY WITH GLL10N AND GLL20N) STANDARD INTERNAL 3-WAY VALVE, WITH FAST CONNECTION ACTUATOR AND VISUAL POSITION SIGNALLING VERSION WITH 2-WAY VALVE FOR VARIABLE WATER FLOW RATE SYSTEMS VERSION WITHOUT VALVES HEAT EXCHANGE COIL WITH SHAPED PROFILE AND ENHANCED SURFACE FAN PURPOSELY DESIGNED FOR LOW SOUND EMISSIONS VERSIONS FOR 2-PIPE AND 4-PIPE SYSTEMS ALSO AVAILABLE WITH ELECTRIC HEATER FOR HEATING Features
8 sizes for 2-pipe versions: FCL 32-36-42-62-72-82-102-122 7 sizes for 4-pipe versions: FCL 34-38-44-64-84-104-124 Standard preparation with standard internal three-way valve, with fast connection actuator and position visual signalling. FCL_V2 preparation (available upon request), with internal two-way valve, suitable for variable water flow rate systems. FCL_VL preparation (available upon request), without internal valve. 3 configurations on one cassette-type fan coil: - louvers that can be oriented by means of a remote control and electronic control if coupled with the accessory GLL10M; - with remote control, louvers that can be oriented manually and by means of electronic control if coupled with the accessory GLL10R or GLL20R; - with louvers that can be oriented manually if coupled with the accessory GLL10 or GLL20, also requires a wired control panel (accessory). High design aesthetics. Grille dimensions perfectly integrable in standard suspended ceiling panels of 600x600mm and 840x840mm for the most powerful units. Fan designed for low sound emissions. 3-speed and 4-speed mixed flow (axial + centrifugal) fan unit for larger sizes (FCL 42-44-62-64-72-82-84-102-104-122-124), in order to select the 3 speeds that best meet delivered power and quiet operation requirements. The load-bearing structure, reinforced with a galvanised steel side band, contains insulation elements in expanded polystyrene obtained from injection moulding for purposes of noise reduction and air routing (FCL 42-4462-72-64). Structure made entirely of galvanised steel, containing insulation elements in closed cell expanded polystyrene and externally covered with anti-condensate felt (FCL 82-84-102104-122-124). Condensation drip tray in one piece, with V0 self-extinguishing level and overmoulding to insulation in expanded polystyrene with flame retardant additive. Heat exchanger with shaped profile to increase the exchange surface, and easily accessible drain valves. Continuous fan operation to prevent stratification of room air. Possibility of direct release of external air regardless of indoor unit ventilation. Possibility to control the climate of adjacent rooms as well. The versions FCL 82-84-102104-122-124 allow 3-direction delivery. Air filter easily removed and cleaned, selfsupporting structure, characterised by a high efficiency and low pressure drops, with classV0 fire resistance (UL 94). Electrostatically pre-charged air filter regenerated with fire resistance class 2 (UL 900), (FEL 10 accessory for GLL10, GLL10R, GLL10M). Full compliance with safety regulations. Easy installation and maintenance.

36

Accessories
Compulsary GLL accessories, essential for unit operation: GLL10M (600x600) Delivery grille with adjustable louvers by means of a remote control and air intake, supplied with an infrared receiver with emergency operation switch. White RAL 9010. GLL10R (600x600) GLL20R (840x840) Delivery grille with louvers manually adjustable and air intake. With remote control, supplied with an infrared receiver with emergency operation switch. White RAL 9010. GLL10 (600x600) GLL20 (840x840) Delivery grille with louvers manually adjustable and air intake. Combined with wallmounted control panel. White RAL 9010. GLL10N (600x600) GLL20N (840x840) Delivery grille with Manually adjustable fins and air intake, with "VMF System" advanced electronic thermostat. Individual units, or network master also requires a wired control panel (VMF-E4 compulsory accessory). White RAL 9010. Control panels and VMF System: the characteristics are described on the appropriate card. Accessories: FCLMC10 FCLMC20 is a perimeter case in galvanised and painted sheet steel, which is used when the fan coil is installed outside the suspended ceiling. It is used for aesthetics and protection, therefore the technical features of the FCL and FCLI remain unvaried. FEL10 : electrostatically pre-charged air filter, regenerated with fire resistance class 2 (UL 900). KFL : Delivery flange, allowing the air to be directed to an adjacent room. KFL20 (***) : delivery flange, allowing the air to be directed to an adjacent room. Up to three KFL20 can be assembled on a single unit. KFLD : suction flange, allows to introduce external air directly into the room without mixing. KFLD20 (***) : suction flange, allows to introduce external air directly into the room without mixing. Up to two KFL20D can be assembled on a single unit. RXLE - RXLE20 : electric heater for heating, can be installed on the single-fan FCL units. Requires GLL-M or GLL-R. SIT 3-5 : Thermostat Interface Cards. They allow the creation of a network of fan coils (max. 6) commanded by a central control panel (selector or thermostat). SIT3 : commands the 3 fan speeds and must be installed on each fan coil of the network; receives the commands from the selector or the SIT5 card. SIT5: commands the 3 fan speeds and up to 2 valves (four pipes systems); transmits the thermostat commands to the network of fan coils fitted with SIT3. SW3 : Minimum water temperature probe, to be used with electronic PXAE thermostats. SW4 : Minimum water temperature probe, to be used with the units fitted with a grille with remote control. Conpulsury with GLL_M, GLL_R, GLL_N SWA : External SWA probe accessory for FMT21 panels. Detects the ambient air temperature if connected to the connector (A); the probe in the panel will be automatically disabled. Detects the temperature of the water in the system, for ventilation consent, if connected to the connector (W) (Length L = 6m) VHL1 - VHL20 : motor-driven three-way valve for the heating battery in 4-pipe systems. Obligatory accessory in 4-pipe systems. VHL2 - VHL22 : motor-driven two-way valve for the heating battery in 4-pipe systems. Obligatory accessory in 4-pipe systems with variable flow rates.

Mod. FCL GLL10 GLL10M** GLL10R** GLL10N** GLL20 GLL20R** GLL20N** FCLMC10 FCLMC20 FEL10 KFL KFL20*** KFLD KFLD20*** RXLE** RXLE20** SW3* SW4** SWA* VHL1 VHL20 VHL2 VHL22 SIT 3* SIT 5* FMT10* FMT21* PX* PX2*- PX2C6**** PXAE* WMT10* VMF-E4*****

32

34

36

38

42

Compatibility of accessories 44 62 64

72

82

84

102

104

122

124

* Accessories that can only be used in combination with GLL10 and GLL20 grilles. ** SW4 mandatory with GLL_M, GLL_R, GLL_N *** A maximum of three KFL20 / KFL20D can be assembled on a single unit

**** PX2C6 = Multiple package of n6 PX2 control panels ***** Accessories that can only be used in combination with the GLL10N and GLL20N grilles for individual units or network master

37

Technical data
Mod. FCL Heating capacity* 50C (E) Water flow rate* 50C Pressure drops* (VL) 50C (E) Total cooling capacity (E) Sensible cooling capacity (E) Water flow rate Pressure drops (VL) (E) Air flow rate (E) Fans Sound power (E) Sound pressure Heat exchanger water content Water connections Kvs (standard version 3R valve) Input power (E) Input current Starting current (max.) (max.) 2-pipe versions vel. (max) vel. (max) vel. (max) vel. (max.) vel. (max.) vel. (max.) vel. (max.) vel. 4 vel. 3 vel. 2 vel. 1 (min) vel. (max.) vel. 4 vel. 3 vel. 2 vel. 1 (min.) W l/h kPa W W l/h kPa m/h m/h m/h m/h n. dB(A) dB(A) dB(A) dB(A) dB(A) l Gas W A A 32 2380 327 9 1900 1520 327 10 600 410 300 1 46 37 29 26 1,2 3/4 2,5 45 0,22 0,66 36 3750 516 14 3000 2400 516 15 600 410 300 1 46 37 29 26 1,5 3/4 2,5 45 0,22 0,66 42 4950 679 23 3950 3160 679 25 700 530 360 260 1 53 44 37 29 26 1,5 3/4 2,5 75 0,33 0,99 62 6250 857 32 4980 3810 857 36 880 660 500 380 1 61 52 45 38 32 2,1 3/4 2,5 83 0,37 1,11 72 6750 939 38 5460 4100 939 43 900 680 520 400 1 63 54 47 40 34 2,1 3/4 2,5 93 0,4 1,2 82 7100 1032 23 6000 4200 1032 25 1100 830 680 460 1 50 41 36 34 30 3 3/4 4 150 0,70 2,10 102 10600 1548 25 9000 6660 1548 28 1350 1010 830 560 1 54 45 39 36 31 4,5 3/4 4 155 0,69 2,07 122 13000 1892 34 11000 8470 1892 38 1750 1350 1100 750 1 60 51 45 41 35 4,5 3/4 4 175 0,75 2,25

Mod. FCL Heating capacity 70C (E) Water flow rate 70C Pressure drops 70C (VL) (E) Total cooling capacity (E) Sensible cooling capacity (E) Water flow rate Pressure drops (VL) (E) Air flow rate (E) Fans Sound power (E) Sound pressure Heat exchanger water content Heat exchanger water content (hot circuit) Water connections Water connections (hot circuit) Kvs (standard version 3R valve) Kvs (hot circuit valve) Input power (E) Input current Starting current

4-pipe versions vel. (max) vel. (max) vel. (max) vel. (max.) vel. (max.) vel. (max.) vel. (max.) vel. 4 vel. 3 vel. 2 vel. 1 (min) n. vel. (max.) vel. 4 vel. 3 vel. 2 vel. 1 (min.) l l Gas Gas

W l/h kPa W W l/h kPa m/h m/h m/h m/h dB(A) dB(A) dB(A) dB(A) dB(A)

(max.) (max.)

W A A

34 2600 224 11 1900 1520 327 10 600 410 300 1 46 37 29 26 1,2 0,3 3/4 1/2 2,5 1,6 45 0,22 0,66

38 2600 224 11 2770 2240 476 13 600 410 300 1 46 37 29 26 1,5 0,5 3/4 1/2 2,5 1,6 45 0,22 0,66

44 3070 264 14 3650 2920 628 22 700 530 360 260 1 53 44 37 29 26 1,5 0,5 3/4 1/2 2,5 1,6 75 0,33 0,99

64 3800 327 21 4610 3530 793 31 880 660 500 380 1 61 52 45 38 32 2,1 0,6 3/4 1/2 2,5 1,6 83 0,37 1,11

84 8500 731 14 6000 4200 1032 25 1100 830 680 460 1 50 41 36 34 30 3 1,5 3/4 1/2 4 2,5 150 0,70 2,10

104 10000 860 19 7200 5300 1238 26 1350 1010 830 560 1 54 45 39 36 31 4,5 1,5 3/4 1/2 4 2,5 155 0,69 2,07

124 12500 1075 29 8800 6770 1514 38 1750 1350 1100 750 1 60 51 45 41 35 4,5 1,5 3/4 1/2 4 2,5 175 0,75 2,25

Power supply = 230V ~ 50Hz (E) = EUROVENT certificate performances

The performances are the same for all the configurations: FCL (standard), FCL V2 and FCL VL. Performance values refer to the following conditions: Sound pressure measured in an 100 m 3 semi-reverberant test chamber with reverberation time Tr = 0.5s Cooling: - room air temperature 27C B.S. ; 19C B.U. - inlet water temperature 7C ; Dt water 5C - maximum speed Heating - room air temperature 20C - inlet water temperature 70C ; Dt water 10C - maximum speed Heating *: - room air temperature 20C - inlet water temperature 50C - maximum speed

38

Dimensions (mm)
FCL 32 - 34 - 36 - 38 - 42 - 44 - 62 - 64 - 72 FCL 32 V2 - 34 V2 - 36 V2 - 38 V2 - 42 V2 - 44 V2 - 62 V2 - 64 V2 - 72 V2 FCL 32 VL - 34 VL - 36 VL - 38 VL - 42 VL - 44 VL - 62 VL - 64 VL - 72 VL

GLL10N GLL10N
Mod. FCL
Weight

kg

32 20,5 32 V2 20,5 32 VL 20

34 21 34 V2 21 34 VL 20,5

36 20,5 36 V2 20,5 36 VL 20

38 21 38 V2 21 38 VL 20,5

42 20,5 42 V2 20,5 42 VL 20

44 21 44 V2 21 44 VL 20,5

62 22 62 V2 21 62 VL 21,5

64 22,5 64 V2 22,5 64 VL 22

72 22,5 72 V2 22,5 72 VL 22

Mod. FCL
Wheigt

kg

Mod. FCL
Weight

kg

FCL 82 - 84 - 102 - 104 - 122 - 124 FCL 82 V2 - 84 V2 - 102 V2 - 104 V2 - 122 V2 - 124 V2 FCL 82 VL - 84 VL - 102 VL - 104 VL - 122 VL - 124 VL

GLL20N

GLL20N
Mod. FCL
Weight

kg kg kg

82 35 82 V2 35 32 VL 34

84 36 84 V2 36 34 VL 35

102 36 102 V2 36 102 VL 35

104 36 104 V2 36 104 VL 35

122 36 122 V2 36 122 VL 35

124 36 124 V2 36 124 VL 35

Mod. FCL
Weight

Mod. FCL
Weight

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

39

Cod.: SFCLUY.09 / 1302

FCLI
Aermec participate in the EUROVENT program: FC / 2 / H, FC / 4 / H the products are present on the site www.eurovent-certification.com

Cassette-type fancoils with Brushless Inverter motor Continuous 0-100% air flow rate regulation Ceiling and false ceiling installation, cooling power from 1900 up to 11000W
Models: FCLI32 , FCLI42 , FCLI62 FCLI34 , FCLI44 , FCLI64 Models: FCLI82 , FCLI122 , FCLI124 FCLI with accessory FCLMC

GLLI10 - GLLI10N White: RAL 9010

GLLI20 - GLLI20N White: RAL 9010

FCLMC White: RAL 9010

The future is Inverter FCLI is the Aermec range of cassette-type fan coils with continuous 0-100% air flow rate variation and therefore continuous heating/cooling capacity variation. Thanks to the Inverter technology, the FCLI continuously modifies the air flow rate, adapting it - moment by moment to the real needs in the room. This produces considerable advantages in terms of electric savings, comfort and noise reduction compared with a traditional on-off 3-speed fan coil.

VMF SYSTEM WITH GLLI10N AND GLLI20N GRILLES ELECTRIC SAVINGS OF 50% COMPARED WITH A FAN COIL WITH TRADITIONAL 3-SPEED MOTOR VERY QUIET OPERATION TOTAL COMFORT: REDUCED TEMPERATURE AND HUMIDITY VARIATIONS IN THE AIR-CONDITIONED ROOMS STANDARD INTERNAL THREE-WAY VALVE, WITH FAST CONNECTION ACTUATOR AND POSITION VISUAL SIGNALLING VERSION WITH 2-WAY VALVE FOR VARIABLE WATER FLOW RATE SYSTEMS VERSION WITHOUT VALVES THERMAL EXCHANGE BATTERY WITH SHAPED PROFILE AND ENHANCED SURFACE FAN FOR LOW SOUND EMISSIONS VERSIONS FOR SYSTEMS WITH 2 AND 4 PIPES
Features
Fan unit with Brushless motor (Continuous 0-100% speed variation); 5 sizes for 2-pipe versions: FCLI 32-42-62-82-122 4 sizes for 4-pipe versions: FCLI 34-44-64-124 Standard preparation with standard internal three-way valve, with fast connection actuator and visual signalling of the position FCLI_V2 preparation (available upon request), with internal two-way valve, suitable for variable water flow rate systems FCLI_VL preparation (available upon request), without internal valve Requires matching with the obligatory accessories, grill and control panel, necessary for the operation High design aesthetics Grille dimensions that can be perfectly incorporated into standard suspended ceiling panel sizes (600x600 mm) and (840X840) for more powerful units. Fan for low sound emissions EUROVENT certification The load-bearing structure, reinforced with a galvanised steel side band, contains insulation elements in expanded polystyrene obtained from injection moulding for purposes of noise reduction and air routing The condensation drip tray is in one piece, with V0 self-extinguishing level and joined by means of over-moulding technology to the insulation in expanded polystyrene with flame retardant additive Heat exchanger with shaped profile to increase the exchange surface, and easily accessible drain valves Possibility of direct release of external air regardless of indoor unit ventilation Possibilit di condizionare anche locali attigui Air filter easily removed and cleaned, selfsupporting structure, characterised by a high efficiency and low pressure drops, with a fire resistance class V0 (UL 94) Electrostatically pre-charged air filter regenerated with fire resistance class 2 (UL 900), (FEL 10 accessory) Full compliance with the accident prevention standards Ease of installation and maintenance

40

Brushless electric motor


Air temperature in the air-conditioned room

Traditional fan coil with 3-speed motor FCLI Inverter with Brushless motor

Set point

Time (s) The "brushless" electric motor is the result of combining the most sophisticated technologies from the fields of mechanics and electronics. "Brushless" literally means "without brushes". The brushless electric motor has no sliding contacts between the rotor and the stator. In brushless motors, the rotor consists of permanent magnets whose magnetic field interacts - without any mechanical contact with the stator windings. With the special inverter device, it is possible to control the speed and torque of the rotor continuously, just by means of the stator currents. Compared with the traditional alternate current motors, the brushless motor offers huge advantages: - Reduced wear and tear - The possibility to adjust the rotation speed accurately and continuously (0-100%) - Higher energy yields - Longer life and greater reliability These characteristics have made the brushless motor irreplaceable in a wide variety of applications: - robotics - automotive - precision drives - CD/DVD players - medical equipment - etc. Thanks to Aermec's FCLI range of inverter fan coils, brushless technology can now make inroads in the field of chilled water air conditioning, bringing notable notevoli vantaggi di energy savings along with the precise control of both air temperature and humidity in the air-conditioned rooms

Accessories
Obligatory accessories, essential for unit operation: GLLI10 (600x600) GLLI20 (840x840) Delivery grille with louvers manually adjustable and air intake. Combined with wallmounted control panel. White RAL 9010. WMT20 : Control panel with electronic thermostat and LCD monitor. Wall mounting. SWI : Water temperature probe for WMT20 control panels. Cable length L = 2m. GLLI10N (600x600) GLLI20N (840x840) Delivery grille with Manually adjustable fins and air intake, with "VMF System" advanced electronic thermostat. Individual units, or network master also requires a wired control panel (VMFE4 compulsory accessory). White RAL 9010. VMF-E4 : Control panel VMF System with Mod. FCLI 32 GLLI10 GLLI20 WMT20 GLLI10N GLLI20N VMF-E4 * FCLMC10 FCLMC20 ** FCLMC20IK ** FEL10 KFL KFL20 KFLD KFLD20 VHL1 VHL2 SWI SW4 * VMF-SW1 * * Accessory for GLLI_N 34 electronic thermostat and LCD monitor. Wallmounting SW4 : Water temperature probe for the control of maximum / minimum temperature (2-pipe system) or for the control of minimum temperature in the heating coil (4-pipe system) VMF-SW1 : Water temperature probe for the control of maximum temperature in the cooling coil (4-pipe system) Control panels and VMF System: the characteristics are described on the appropriate card. Accessories: FCLMC10 FCLMC20 : is a perimeter case in galvanised and painted sheet steel, which is used when the fan coil is installed outside the suspended ceiling. It is used for aesthetics and protection, therefore the technical features of the FCL and FCLI remain unvaried. FCLMC20 42 Compatibility of accessories 44 62 64 requires the combination with the FCLMC20IK accessory. FCLMC20IK : Installation kit for Controller Inverter, compulsory for units with FCLM20. FEL10 : electrostatically pre-charged air filter, regenerated with fire resistance class 2 (UL 900). KFL10 KFL20 : Delivery flange, allowing the air to be directed to an adjacent room. KFLD KFLD20 : suction flange, allows to introduce external air directly into the room without mixing. VHL1 : motor-driven three-way valve for the heating battery in 4-pipe systems. Obligatory accessory in the 4-pipe systems. VHL2 : motor-driven two-way valve for the heating battery in 4-pipe systems. Obligatory accessory for 4-pipe systems with variable flow rates.

82

122

124

** FCLMC20 requires the combination with the FCLMC20IK accessory

41

Technical data
Mod. FCLI Heating capacity 50C (E) Pressure drops (VL) 50C (E) Total cooling capacity (E) Sensible cooling capacity (E)vel. (max) Water ow rate Pressure drops (VL) (E) Air ow rate (E) Fans Sound power (E) Sound pressure 2-pipe versions vel. (max) vel. (max) vel. (max) W vel. (max) vel. (max) vel. (max) vel. (min) vel. (max) vel. (max) vel. (min) W kPa W l/h kPa m/h m/h n. dB(A) dB(A) dB(A) l Gas W A 32 2380 9 1900 1520 327 10 600 150 1 46 37 22 1,2 3/4 2,5 33 0,28 42 4950 23 3950 3160 679 25 700 150 1 53 42 23 1,5 3/4 2,5 55 0,43 62 6250 16 4980 3815 857 36 880 150 1 61 52 24 2,1 3/4 2,5 61 0,47 82 7100 21 6000 4200 1032 25 1100 350 1 50 41 31 3 3/4 4 80 0,71 122 13000 34 11000 8470 1892 38 1750 350 1 60 51 31 4,5 3/4 4 90 0,8

Heat exchanger water content Water connections Kvs (standard version 3R valve) Input power (E) Input current

(max) (max)

Mod. FCLI Heating capacity 70C Water ow rate 70C (E) Pressure drops (VL) 70C (E) Total cooling capacity (E) Sensible cooling capacity (E)vel. (max) Water ow rate Pressure drops (VL) (E) Air ow rate (E) Fans Sound power (E) Sound pressure

4-pipe versions vel. (max) vel. (max) W vel. (max) vel. (max) vel. (max) vel. (min) vel. (max) vel. (max) vel. (min) l/h W kPa W l/h kPa m/h m/h n. dB(A) dB(A) dB(A) l l Gas Gas

Heat exchanger water content Heat exchanger water content (hot circuit) Water connections Water connections (hot circuit) Kvs (standard version 3R valve) Kvs (hot circuit valve) Input power (E) Input current

(max) (max)

W A

34 2600 224 11 1900 1520 327 10 600 150 1 46 37 22 1,2 0,3 3/4 1/2 2,5 2,5 33 0,28

44 3070 264 14 3650 2920 628 22 700 150 1 53 42 23 1,5 0,5 3/4 1/2 2,5 2,5 55 0,43

64 3800 327 21 4610 3530 793 31 880 150 1 61 52 24 2,1 1,5 3/4 1/2 2,5 2,5 61 0,47

124 12500 1075 29 8800 6770 1514 38 1750 350 1 60 51 31 4,5 4,5 3/4 1/2 4 2,5 90 0,8

Power supply = 230V ~ 50Hz (E) = EUROVENT certificate performances

The performances are the same for all the configurations: FCLI (standard), FCLI V2 and FCLI VL. Performance values refer to the following conditions: Sound pressure measured in an 100 m 3 semi-reverberant test chamber with reverberation time Tr = 0.5s Cooling: - room air temperature 27C B.S. ; 19C B.U. - inlet water temperature 7C ; Dt water 5C - maximum speed Heating - room air temperature 20C - inlet water temperature 70C ; Dt water 10C - maximum speed Heating *: - room air temperature 20C - inlet water temperature 50C - maximum speed

42

Dimensions (mm)
FCLI 32 - 34 - 42 - 44 - 62 - 64 FCLI 32 V2 - 34 V2 - 42 V2 - 44 V2 - 62 V2 - 64 V2 FCLI 32 VL - 34 VL - 42 VL - 44 VL - 62 VL - 64 VL

GLLI 10 GLLI 10N Mod. FCLI Weight Mod. FCLI Weight Mod. FCLI Weight kg 32 20,5 32 V2 20,5 32 VL 20 34 21 34 V2 21 34 VL 20,5 42 20,5 42 V2 20,5 42 VL 20

GLLI 10 GLLI 10N

44 21 44 V2 21 44 VL 20,5

62 22 62 V2 21 62 VL 21,5

64 22,5 64 V2 22,5 64 VL 22

kg

kg

FCLI 82 - 122 - 124 FCLI 82 V2 - 122 V2 - 124 V2 FCLI 82 VL - 122 VL - 124 VL

FCLI

GLLI 20 GLLI20 GLLI 20N

GLLI 20 GLLI20 GLLI 20N Mod. FCLI Weight Mod. FCLI Weight Mod. FCLI Weight 82 35 82 V2 35 32 VL 34 122 36 122 V2 36 122 VL 35 124 36 124 V2 36 124 VL 35 Cod.: SFCLIUY.04/ 1210

kg

kg

kg

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Telephone 0442633111 - Telefax 044293730 www.aermec.com

43

FHX

Fan coils With germicidal lamp

Ge rm inc icida orp l l ora am ted p

Aermec participate in the EUROVENT program: FC / 2 / H the products are present on the site www.eurovent-certification.com

FHX-UVP FHX-UVPO

FHX-UV

The FHX fan coil is fitted with an exclusive device for air sterilization, making it essential in environments that require the highest levels of hygiene, such as:

hospitals dentists' surgeries doctors' and vets' surgeries analysis laboratories pharmaceutical companies

waiting rooms beauty institutes homes offices public premises

Features
Available in 6 sizes and 3 versions: FHX-UV: universal free-standing or wall/ceiling mounting. FHX-UVP : wall-mounted model without cabinet. FHX-UVPO : wall-mounted model without cabinet, with boosted motor at 6/7 speeds (3 selectable). EUROVENT certification. Compatible with VMF System. Exclusive air sterilization system with germicidal lamps. Efficiency of 99.999% in the deactivation of all microorganism Gram - and Gram + 3 row coil. 3-speed ventilating unit. Full compliance with the accident prevention standards. Rounded line. Quiet operation. Low loss of charge in the heat exchange batteries. Electric motors with permanently inserted condensers. Ease of installation and maintenance. Air filter easy to remove and clean. Control made by a microprocessor thermostat supplied as an accessory: - FHX-UVP and UVPO: requires external control panel. - FHX-UV: The control panel may be fitted on board the unit or externally. FHX-UV: Metal protection cabinet with varnishing in anticorrosion polyester, colour RAL9002. FHX-UV: The air delivery and suction louvers are made of plastic material, colour RAL7044 Adjustable air delivery louver on version UV except models 62 and 82.

44

Accessories
BC: Auxiliary condensate drip tray. GA: Intake louver with fixed slats. GAF: Intake louver with fixed slats and filter. GM: Delivery louver with adjustable slats. PA: Intake Plenum made of galvanized steel sheet, provided with Intake Connections for Circular Section Ducts. PA-F: Intake plenum that allows to have the intake and the delivery on the same side, suitable for all the installations where it is requested to put the appliance outside the airconditioned rooms in order to reduce to the minimum the noise and facilitate the maintenance operations. PC: Rear cover panel. Conveniently covers exposed rear fancoil sections. The panel is required by current safety standards for units installed away from the room wall. PM: Delivery plenum in galvanized steel with external insulation, with plastic outlet connections for circular section ducting. RD: Delivery straight duct connection. RDA: Intake straight duct connection. RP: Delivery 90 duct connection. RPA: Intake 90 duct connection. SE: Manually operated fresh air intake louver. SIT 3-5 : Thermostat interface cards. They allow to set up a fancoils network (max. 10) commanded by a centralised panel (switch or thermostat). SIT3: commands the three speeds of the fan and must be installed on each fancoil of the network; it receives the commands from the switch or from the SIT5 card. SIT5: commands the 3 fan speeds and up to two valves (four-pipe systems); it sends the thermostat commands to the fancoils network. SW : Probe for the electronic thermostats which permits operation of the unit only with water above 35 C. VCF: The SW3 probe must be combined to this accessory. Kit complete with copper connections and 3 way valves all or nothing type, to be powered by a 230 V ~ 50Hz, 24 V ~ 50Hz voltage supply. Attention: The VCF valve and the drip tray BC4 can be installed at the same time as the fan coil. VCFD: The SW3 probe must be combined to this accessory. Kit complete with copper connections and 2 way valves all or nothing type, to be powered by a 230 V ~ 50Hz, 24 V ~ 50Hz voltage supply. Attention: The VCFD valve and the drip tray BC4 can be installed at the same time as the fan coil. ZX: Feet for built-in installation. Control panels and VMF System: the characteristics are described on the appropriate card.

Accessories 22 4 5 6 8* 9* 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 22F 32F 42F 62F 23 33 43 62 22 32 42 62


32

42

Size (FHX) 50 62 82

Accessories Versions UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UV UV UV UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UV-UVP-UVPO UV 22 RD 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 20X 30X 40X 80X

32

42

Size (FHX) 50 62 82

BC

RDA

GA

RP

GAF

RPA

GM

SE** SIT3 SIT5 SW3

PA

PA

PC

PM PXAE PXAI

41 42 43 VCF 4124 4224 4324 1 2 3 VCFD 124 224 324 7 ZX 8

Versions UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UV-UVP-UVPO UVP-UVPO UVP-UVPO

(*) BC8 and BC9 are not applicable to fan coils with cover cabinets (**) SE accessories are matched with ZX feet

45

Technical data
Mod. Heating capacity Heating capacity (inlet water 50C) Water capacity Water pressure drops Total cooling capacity W (max.) W (med.) W (min.) W (E) l/h kPa W (max.) (E) W (med.) W (min.) W (max.) (E) W (med.) W (min.) l/h kPa (E) m3/h (max.) m3/h (med.) m3/h (min.) n. dB (A) (max.) dB (A) (med.) dB (A) (min.) dB (A) (max.) (E) dB (A) (med.) (E) dB (A) (min.) (E) l W A
(FHX-UV / UVP) (FHX-UVPO) (FHX-UV / UVP) (FHX-UVPO)

Sensitive cooling capacity Water capacity Water pressure drops Air capacity Number of fans Sound pressure Sound power Water content Total input power Total input current Battery connections 3R Battery connections 1R (BV)

FHX 22 3400 2700 1915 2100 292 6,3 1500 1330 1055 1240 1055 755 258 5,8 290 220 140 1 41,5 34,5 22,5 50 43 31 0,79 50 79 0,24 0,37 1/2 1/2

FHX 32 4975 4085 3380 3160 427 14,2 2210 2055 1570 1750 1540 1100 380 16,6 450 350 260 2 39,5 32,5 25,5 48 41 34 1,11 69 122 0,33 0,57 1/2 1/2

FHX 42 7400 6415 5115 4240 636 14,1 3400 2800 2310 2760 2115 1635 585 14,3 600 460 330 2 42,5 35,5 28,5 51 44 37 1,48 82 136 0,4 0,63 3/4 1/2

FHX 50 8620 7530 5420 4900 741 14,2 4190 3640 2840 3000 2750 2040 721 19,3 720 600 400 2 47,5 42,5 33,5 56 51 42 1,48 92 107 0,47 0,48 3/4 1/2

FHX 62 12920 10940 8330 6460 1110 14,8 4860 4660 3950 3980 3510 2825 836 11,6 920 720 520 3 48,5 42,5 33,5 57 51 42 2,52 182 197 0,84 0,92 3/4 1/2

FHX 82 15140 13350 10770 7990 1300 19,8 7420 5500 4710 5680 4250 3450 1276 13,5 1140 930 700 3 53,5 48,5 41,5 62 57 50 2,52 206 235 0,93 1,06 3/4 1/2

Electrical power supply = 230V ~ 50Hz The performance refers to the following conditions: Level of sound pressure (A-weighted) measured in the room with volume V=85m3; reverberation time t=0.5s ; direction factor Q=2; distance r=2.5m Cooling: - room air temperature 27C D.B. ; 19C W.B. maximum speed: - water inlet temperature 7C ; Dt water 5C medium and minimum speed: - water inlet temperature 7C - water flow rate same as at maximum speed

(E) = Performance EUROVENT certification

Heating: room air temperature 20C D.B. maximum speed: - water inlet temperature 70C ; Dt water 10C medium and minimum speed: - water inlet temperature 70C - water flow rate same as at maximum speed maximum speed (water inlet 50C): - water inlet temperature 50C - water flow rate same as in cooling operation

46

Dimensions (mm)

FHX 22 UV - 32 UV - 42 UV - 50 UV

FHX 62 UV - 82 UV

Mod. FHX Height Width Weight

D E [kg]

22 UV 520 750 16

32 UV 520 980 26

42 UV 520 1200 25

50 UV 520 1200 25

62 UV 590 1320 35

82 UV 590 1320 35

FHX 22 - 32 - 42 - 50 UVP FHX 22 - 32 - 42 - 50 UVPO

FHX 62 - 82 UVP FHX 62 - 82 UVPO

Mod. FHX A B C [kg]

Weight

22 UVP/UVPO 572 522 440 16

32 UVP/UVPO 823 753 671 26

42 UVP/UVPO 1043 973 891 25

50 UVP/UVPO 1043 973 891 25

62 UVP/UVPO 1205 1122 1102 35

82 UVP/UVPO 1205 1122 1102 35

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

47

Cod.: SFHXUY.03 / 0912

NEW

VED

Fan coil unit with cooling capacity from 0.99 to 5.82 kW For ducted installations

Aermec participates in the EUROVENT Certification Programme FCP / 2 / H. The products of interest can be found on the site: www.eurovent-certification.com

LARGE RANGE OF ACCESSORIES HORIZONTAL OR VERTICAL INSTALLATION COMPATIBLE WITH THE VMF SYSTEM VERSIONS FOR 2/4 PIPE SYSTEMS 1 ROW HEATING ONLY COIL (ACCESSORY BV) LARGE RANGE OF AVAILABLE STATIC PRESSURE Unit selection

6/7 SPEED FAN ASSEMBLY CENTRIFUGAL FANS IN ANTI-STATIC PLASTIC MATERIAL ACCESSIBLE FAN ASSEMBLY INTERNAL INSULATION WITH FIRE RETARDANT PROTECTION TO CLASS 1 AIR FILTER CLASS G3 REVERSIBLE COIL

By choosing the appropriate options it is possible to select the model to suit the specific system requirements.

Configuration fields:
123 Code 4 Size 5 Main Coil 6 0

Example:
123 4 VED 0 (VED030 = unit Size 0, with 3 Row Main Coil) 5 3 6 0

Characteristics
Ducted air conditioning terminal unit EUROVENT FCP Certification Programme Horizontal and vertical installation Internal installation Available in 8 sizes 3 or 4 row coils for 2-pipe systems 3 row main coil and heating only coil accessory for 4-pipe systems Reversing of hydraulic connections side on site Low pressure drop heat exchanger 3-way valve accessory 2-way valve accessory for variable flow systems 6 and 7 speed fan assembly (3 selectable) Large range of available static pressure Centrifugal fans in anti-static plastic material. Their characteristics permit energy savings compared to conventional fans Fans with aerofoil profile designed to achieve high airflows and pressures whilst at the same time producing low noise Compatible with the VMF system Large range of controllers Large range of accessories to satisfy all installation requirements Compatible with many accessories already available on the FCX range Discharge connection supplied loose Air filter Class G3, for easy removal and cleaning Internal insulation in Class 1 fire retardant material Protective rating IP20 Fan housing in plastic material removable for easy and effective cleaning Ease of installation and maintenance Full compliance with safety standards.

48

Accessories
DUCTING ACCESSORIES Plenum in galvanised sheet steel and connections: RDA_V: Straight intake connection with rectangular flange. RDAC_V: Straight intake connection with circular flanges. RPA_V : Intake plenum with rectangular flange. RDMC_V : Straight discharge with circular flanges. Internally insulated. PA_V: Intake plenum with circular flanges. Flanges in plastic material. RPM_V: Discharge plenum with rectangular flange. Internally insulated. PM_V: Discharge plenum with circular flanges. Internally insulated. Flanges in plastic material. KFV10 : Circular flanges kit for intake/discharge plenum. Discharge and intake grilles: GA: Intake grille with fixed louvres. GAF: Intake grille with fixed louvres with filter. GM: Discharge grille with adjustable louvres. SE: External air damper with manual control. INSTALLATION ACCESSORIES AMP: Hanging kit. Compatibilit BC: auxiliaryaccessori condensate drain tray. DSC4: Condensate pump to overcome lifts. Accessory Compatibility
Mod.VED RDA000V RDA100V RDA200V RDA300V RPA000V *** RPA100V *** RPA200V *** RPA300V *** RDAC000V RDAC100V RDAC200V RDAC300V PA000V *** PA100V *** PA200V *** PA300V *** PM000V *** PM100V *** PM200V *** PM300V *** RPM000V *** RPM100V *** RPM200V *** RPM300V *** RDMC000V RDMC100V RDMC200V RDMC300V BV030 BV130 BV230 BV162 KFV10 VMF-EO VMF-E1 VMF-SW VMF-SW1 VMF-E4/E4D VMF-E5N/E5B FMT10 FMT21 TPF 030 040 130 140 230 240 330 340 Mod.VED SWA KTLP PX PX2 - PX2C6 PXAR PXAE WMT05 WMT06 WMT10 SW3 SIT3 SIT5 VCF43-4324 * VCF45-4524 * VCFD3-324 * VCFD4-424 * VCF3X4R VCF3X4L AMP BC4 * / ** BC6 ** BC9 ** DSC4 ** GA22 GA32 GA42 GA62 GAF22 GAF32 GAF42 GAF62 GM22 GM32 GM42 GM62 SE20X **** SE30X **** SE40X **** SE80X **** ZX7 ZX8 030 4 4 040 4 4 130 4 4 140 4 4 230 4 4 240 4 4 330 4 4 340 4 4

ZX: Feet for recessed installation. HEATING ONLY COIL BV: 1 row heating only coil. WATER VALVES For main coil, 230V~50 Hz / 24V~50 Hz VCF43 / 4324: Kit composed of 3-way motorised valve with insulating casing, connections and insulated copper tubes. VCFD3 / 324: Kit composed of 2-way motorised valve with insulating casing, connections and insulated copper tubes. For heating only coil, 230V~50 Hz / 24V~50 Hz VCF45 / 4543: Kit composed of 3-way motorised valve, with connections and insulated copper tubes. VCFD4 / 424: Kit composed of 2-way motorised valve, with connections and insulated copper tubes. VCF3X4: Valve kit for 4 pipe systems and fan coil units with single coil and 2 connections. Kit composed of special 3 way motorised valve

CONTROL PANELS The complete characteristics of the control panels are described in the dedicated files. Some control panels require combination with other accessories; consult the relevant documentation. ACCESSORIES TO COMBINE TO CONTROL PANELS SIT 3 - 5: Thermostat Interface Boards. Allows networking of fan coil units (10 max) controlled by a central panel (switch or thermostat). SIT3: Controls the 3 speeds of the fan and must be installed on each fan coil unit on the network; receives controls from the switch or the SIT5 board. SIT5: Thermostat interface board. Allows a network of VED units (3 max) controlled by a single panel PXAE. SW3: Water temperature sensor for control panel PXAE. SWA: Air and water temperature sensor for with insulating casing, connections and insulated control panel FMT21. copper tubes. VARIABLE MULTI FLOW SYSTEM Version VCF3X4L for left hand connection fan coils. VMFSystem: The complete characteristics of the Version VCF3X4R for right hand connection fan VMF system are described in the dedicated coils. files. Power supply 230V ~ 50Hz. Some VMF components require combination with other accessories; consult the relevant documentation.

* The valve kits VCF and the drain pan BC4 cannot be installed together on the same fan coil unit. ** The accessory DSC4 is not compatible with AMP and BC4 - BC6 - BC9. *** All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) have a circular push-outs (=150mm ) on both sides, which can be removed and used with accessories.

A ll the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) can have intake/discharge either straight or downwards (straight or downwards with reference to horizontal installation). **** Accessories SE must be combined with the feet ZX.

49

Technical data
(1) (2) Mod. VED 030 W (nom) W (max) W (med) W (min) l/h (nom) l/h (max) l/h (med) l/h (min) kPa (nom) kPa (max) kPa (med) kPa (min) W (nom) W (max) W (med) W (min) kPa (nom) kPa (max) kPa (med) kPa (min) W (nom) W (max) W (med) W (min) W (nom) W (max) W (med) W (min) l/h (nom) l/h (max) l/h (med) l/h (min) kPa (nom) kPa (max) kPa (med) kPa (min) m3/h (nom) m3/h (max) m3/h (med) m3/h (min) Pa (nom) Pa (max) Pa (med) Pa (min) n. (nom) (max) (med) (min) W (nom) W (max) W (med) W (min) W A Gas (F) Gas (F) 4205 3688 3374 1820 369 323 296 160 11 9 7 3 2493 2180 1987 1100 10 8 7 3 1878 1623 1453 990 1410 1242 1116 750 323 279 250 170 11 9 7 3 334 285 256 161 50 61 50 21 1 V1 V1 V3 V6 61 59 38 23 70 0.37 3/4" IP20 040 4633 3916 33568 2366 406.2 343 313 207 17 12 10 4 2770 2340 2130 1410 17 12 10 5 2260 1900 1720 1120 1610 1350 1230 810 389 327 295 193 19.6 14 12 5 334 277 249 160 48 61 50 21 1 V1 V1 V3 V6 61 58 38 23 70 0.37 3/4" IP20 130 7302 6289 5833 4397 640 551 511 385 36 26 22 13 4350 3750 3480 2620 36 27 23 13 3447 2997 2790 2080 2440 2090 1940 1440 593 515 480 358 42 31 27 15 516 433 397 287 50 60 50 26 2 V1 V1 V3 V6 78 76 53 34 89 0.41 3/4" IP20 140 7935 6575 6089 4518 696 576 534 396 26 18 16 9 4750 3940 3650 2710 25 19 16 9 3820 3290 3050 2270 2790 2370 2190 1610 657 565 525 392 31 23 20 11 516 420 386 280 46 60 50 26 2 V1 V1 V3 V6 78 75 52 34 89 0.41 3/4" IP20 230 8170 7160 6500 5350 703 616 559 460 48 37 30 27 4920 4320 3920 3230 45 35 29 20 3880 3420 3130 2590 3070 2700 2440 2000 667 589 535 445 56 44 36 25 693 590 524 417 52 64 50 32 2 V1 V1 V4 V6 98 93 57 43 116 0.58 3/4" IP20 240 9449 7909 7141 5800 817 684 616 499 43 3 26 18 5580 4752 4290 3450 42.8 31 26 13 4740 4020 3630 2900 3582 3015 2718 2200 817 692 624 507 49 37 31 16 693 570 509 406 50 63 50 32 2 V1 V1 V4 V6 98 92 57 43 116 0.58 3/4" IP20 330 340 (1) (3) Mod. VED + Accessory BV (heating only with coil BV) 030 130 230 BV030 BV130 BV230 2475 4270 5000 2220 3780 4493 2080 3596 4171 1590 2946 3675 217 374 438 196 331 394 183 315 366 140 258 322 10 35 19 8 28 16 7 25 14 5 17 11 1878 3447 3880 1592 2931 3380 1416 2727 3080 984 2029 2500 1410 2440 3000 1218 2169 2600 1094 1900 2350 745 1400 1900 323 593 667 274 504 581 244 469 530 169 349 430 11 42 56 9 31 42 7 27 35 3 15 23 334 516 693 280 423 582 250 388 513 160 280 412 47 47 49 61 60 64 50 50 50 21 26 32 1 2 2 V1 V1 V1 V1 V1 V1 V3 V3 V4 V6 V6 V6 61 78 98 59 76 93 38 53 57 23 34 43 70 89 116 0.37 0.41 0.58 3/4" 3/4" 3/4" 1/2" 1/2" 1/2" IP20 IP20 IP20 330 BV330 6200 5888 5499 4896 543 515 482 429 28 26 23 19 5250 4946 4380 3600 3800 3670 3280 2720 903 851 753 619 20 18 14 9 855 790 695 568 58 66 50 33 3 V1 V1 V5 V6 107 104 75 63 136 0.66 3/4" 1/2" IP20

Heating capacity 70C (4)

Water ow rate 70C

Water pressure drop 70C

Heating capacity water 50C

Water pressure drop

Cooling capacity total

Cooling capacity sensible

Water ow rate

Water pressure drop

Air ow rate

Available static pressure (5) Number of centrifugal fans Motor connection speed

Power input Maximum power input Maximum current input Coil connections VED Coil connections BV Protective rating

11045 11966 10507 10951 9343 10017 7813 8312 968 1049 921 960 819 878 685 72 18 36 16 32 13 28 9 22 6590 7150 6265 6550 5584 5980 4674 4970 18 25 16 21 13 17 9 13 5250 5820 5000 5360 4420 4790 3680 3980 3920 4300 3738 3990 3337 3570 2803 2950 904 1000 861 924 761 830 634 686 20 30 18 26 14 21 10 16 855 855 805 775 704 685 572 563 62 58 66 64 50 50 33 34 3 3 V1 V1 V1 V1 V5 V5 V6 V6 107 107 104 103 75 74 63 63 136 136 0.66 0.66 3/4" 3/4" IP20 IP20

The performances to the following conditions: Data certified in accordance with Programme Eurovent FCP / 2 / H Power supply: 230V~50Hz (1) Cooling (Eurovent): - Air inlet temperature db - Air inlet temperature wb - Water inlet temperature - Water outlet temperature - Water flow rate with constant T

The nominal velocity represents the upper air flow limit for which the heat exchanger has been sized (4)Data for 3 or 4 row coil and accessory VCF3X4 (5)Air filter Class G3 installed - - - - - - (3) Heating 70C (Eurovent): Air inlet temperature db = 20C Air inlet temperature wb = 15C Water inlet temperature = 70C Water outlet temperature = 60C Water flow rate with constant T Heating coil circuit in unit configured for 4-pipe system

= 27C = 19C = 7C = 12C

- - - -

(2) Heating 50C (Eurovent): Air inlet temperature db = 20C Air inlet temperature wb = 15C Water inlet temperature = 50C Water flow rate as in Cooling test

50

Dimensional data (mm)


VED: 030 - 040 - 130 - 140 - 230 - 240 - 330 - 340

A B 25 25 C 25 24 217 167 24

111

Asola 20x9 253 141

41

96 156 149

0,5

584

350

17,5 273 98 D 378

VED
A B C D Net weight

030 mm mm mm mm
kg 576 550 500 530 20

040
576 550 500 530 21

130
807 781 731 761 23

140
807 781 731 761 24

230
1027 1001 951 981 29,5

240
1027 1001 951 981 32

330
1148 1122 1072 1102 32,5

340
1148 1122 1072 1102 34

The technical data shown in this documentation is not binding. Aermec S.p.A. reserves the right to make all modification deemed necessary for improving the product at any time.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

51

Cod.: SVED0UI.01 / 1302

VED

Air handling terminal with cooling capacities from 8 to 18 kW For ducted systems

AERMEC partecipates in the EUROVENT programme for: FCP/2/H Check ongoing validity of certificate online: www.eurovent-certification.com

WIDE RANGE OF ACCESSORIES HORIZONTAL AND VERTICAL INSTALLATION COMPATIBLE WITH THE VMF SYSTEM VERSIONS FOR 2/4 PIPE SYSTEMS HEAT EXCHANGER ONLY WITH 1 OR 2 ROWS WIDE RANGE OF USEFUL STATIC PRESSURE
Choosing the unit

5 SPEED VENTILATION UNIT CENTRIFUGAL FANS IN ANTISTATIC PLASTIC INSPECTIONABLE FAN UNIT INTERNAL ISOLATION WITH CLASS 1 FIREPROOF PROTECTION CLASS G3 AIR FILTER COIL REVERSIBILITY

By appropriately combining the options available, it is possible to select the model that satisfies the specific system requirements.

Fields configurator:
123 Code 123 VED 4 Size 4 5 5 Main coil n. rows 5 3 6 Heating only coil n. rows 6 2

(VED532 = unit size 5, with Main Coil 3 Rows and Heating Coil 2 Rows)

Features
Air handling terminal for ducted systems EUROVENT FCP Certification Program Horizontal and vertical installation Indoor installation Available in 4 sizes and 4 configurations Versions for 2 pipe systems with 3 or 4 row coil Versions for systems with 4 pipes with main coil with 3 or 4 rows and heating only coil with 1 or 2 rows Reversibility of the hydraulic connection in the installation phase Low pressure drop in the heat exchange coils 3-way valves accessories 2-way valves accessories for systems with variable water flow rate 5 speed fan unit (3 selectable) Wide range of useful static pressure Centrifugal fans in antistatic plastic. Due to their features, they allow to reduce the energy consumption with respect to normal fans Fans with wing-shaped profile studied to obtain high flow rate and static pressure performance and low noise emission at the same time Compatible with the VMF system Wide range of controls Wide range of accessories to satisfy all system requirements Rectangular flow flange already integrated into the framework Class G3 air filter with easy extraction and cleaning Internal insulation in Class 1 fire resistance IP20 protection rating Plastic augers, extractable for easy and efficient cleaning Easy installation and maintenance Full respect of the accident-prevention standards

52

Accessories
RDA_V : Straight fitting with rectangular flange for ducting. In galvanised sheet steel RPA_V: Intake plenum with rectangular flange for ducting. In galvanised sheet steel PA_V: Intake plenum with circular flanges for ducting. In galvanised sheet steel, the flanges are in plastic RPM_V: Flow plenum with rectangular flange for ducting. In galvanised sheet steel, internally isolated. PM_V: Flow plenum with circular flanges for ducting In galvanised sheet steel, internally isolated, the flanges are in plastic KFV: Circular flange kit for intake/flow plenum. In plastic VCF4_C: Kit made up from motorised 3-way valves with isolating shell, fittings and isolated copper pipes. For main coils. 230V~50 Hz power supply VCF4_H: Kit made up from motorised 3-way valves, fittings and isolated copper pipes. For heating only coils. 230V~50 Hz power supply VCF2_C: Kit made up from motorised 2-way valves, with fittings and isolated copper pipes. For main coils. 230V~50 Hz power supply VCF2_H: Kit made up from motorised 2-way valves, with fittings and copper pipes. For heating only coils. 230V~50 Hz power supply coupled to thermostats different to the VMF System SIT5: Thermostat interface board. Allows to realise a network of VED units (max 3) controlled by a centralised PXAE panel SW3: Water minimum temperature probe to use with PXAE control panel.

VARIABLE MULTI FLOW SYSTEM VMF System: The complete fittings of the VMF System management system are described in the dedicated sheet. CONTROL PANELS Some VMF components require coupling with The complete features of the control panels are other accessories, consult the relative described in the dedicated sheet. documentation. Some control panels require coupling with VMF-SIT 3 : Thermostat Interface Board other accessories, consult the relative VMF. Mandatory accessory on the VED unit documentation. supplied with VMF-E0 / E1 thermostat. ACCESSORIES TO COUPLE WITH THE CONTROL PANELS SIT3 : Thermostat interface board Mandatory accessory on the VED units

Mod. VED RDA 450 V RDA 670 V RPA 450 V RPA 670 V PA 450 V PA 670 V RPM 450 V RPM 670 V PM 450 V PM 670 V KFV SW3 SIT 3* SIT 5** PXAE WMT05 WMT06 WMT10 VCF45C VCF45H VCF47C VCF47H VCF25C VCF25H VMF-SIT3*** VMF-E0 VMF-E1 VMF-SW VMF-SW1 VMF-E4 VMF-E5B VMF-E5N

Accessories compatibility
430

432

440

441

530

532

540

541

630

632

640

641

730

732

740

741

* SIT3 ** SIT5 *** VMF-SIT3

=Mandatory accessory on the VED units coupled to thermostats different to the VMF System = Allows to realise a network of VED units (max 3) controlled by a centralised PXAE panel = Mandatory accessory for coupling with VMF-E0 or VMF-E1

53

Technical data
Mod. VED Heating Capacity 70C (heating only coil circuit) 430 432 440 441 530 532 540 541 630 632 640 641 730 732 740 741 W (nominal) - 13875 8990 - 15020 9510 - 22800 - 14800 - 25080 - 15800 W (max.) (E) - 12090 8160 - 13540 8850 - 20500 - 13750 - 22180 - 14500 W (med.) (E) - 10725 7480 - 12850 8520 - 17750 - 12370 - 19720 - 13330 W (min.) (E) 8280 6190 - 10720 7475 - 14690 - 10770 - 16730 - 11830 l/h (nominal) 1193 773 1292 818 1961 1273 2157 1359 l/h (max.) 1040 702 1164 761 1763 1183 1907 1247 l/h (med.) 922 643 1105 733 1527 1064 1696 1146 l/h (min.) 712 532 922 643 1263 926 1439 1017 kPa (nominal) 22 32 25 35 33 31 39 34 kPa (max.) (E) 17 27 21 31 27 27 31 30 kPa (med.) (E) 14 23 19 29 21 23 25 26 kPa (min.) (E) 9 17 14 23 15 18 19 21 W (nominal) 10420 - 11950 - 11340 - 13110 - 18220 - 19600 - 20060 - 21820 W (max.) (E) 9475 - 10740 - 10420 - 11820 - 16070 - 17930 - 17280 - 19150 W (med.) (E) 8250 9130 9775 - 11050 - 13500 - 14940 - 15120 - 16680 W (min.) (E) 6195 6810 8190 9170 - 11100 - 11980 - 12640 - 13840 kPa (nominal) 17 24 19 29 57 37 69 43 13 kPa (max.) (E) 19 16 23 48 32 57 35 kPa (med.) (E) 11 15 15 21 36 24 44 28 kPa (min.) (E) 7 9 11 16 26 17 33 21 W (nominal) 8010 8010 9290 9290 8660 8660 10280 10280 13900 13900 16450 16450 15360 15360 18100 18100 W (max.) (E) 6950 6950 8010 8010 7760 7760 8970 8970 12530 12530 15180 15180 13850 13850 16080 16080 W (med.) (E) 6150 6150 7060 7060 7395 7395 8545 8545 10700 10700 12760 12760 12200 12200 14230 14230 W (min.) (E) 4685 4685 5340 5340 6160 6160 7435 7435 8890 8890 10430 10430 10400 10400 11960 11960 W (nominal) 6225 6225 6675 6675 6755 6755 7255 7255 11500 11500 11590 11590 12770 12770 12800 12800 W (max.) (E) 5360 5360 5735 5735 6020 6020 6450 6450 10300 10300 10660 10660 11440 11440 11320 11320 W (med.) (E) 4715 4715 5040 5040 5715 5715 6130 6130 8750 8750 8910 8910 9990 9990 9970 9970 W (min.) (E) 3545 3545 3785 3785 4720 4720 5040 5040 7220 7220 7240 7240 8480 8480 8340 8340 l/h (nominal) 1378 1378 1598 1598 1490 1490 1768 1768 2391 2391 2829 2829 2642 2642 3113 3113 l/h (max.) 1195 1195 1378 1378 1335 1335 1543 1543 2155 2155 2611 2611 2382 2383 2766 2766 l/h (med.) 1058 1058 1214 1214 1272 1272 1470 1470 1840 1840 2195 2195 2098 2098 2448 2448 l/h (min.) 806 806 918 918 1060 1060 1279 1279 1529 1529 1794 1794 1789 1789 2057 2057 kPa (nominal) 22 22 30 30 26 26 37 37 58 58 47 47 70 70 56 56 kPa (max.) (E) 17 17 22 22 21 21 28 28 48 48 41 41 58 58 45 45 kPa (med.) (E) 13 13 17 17 19 19 25 25 36 36 30 30 46 46 37 37 kPa (min.) (E) 8 8 10 10 13 13 19 19 26 26 21 21 35 35 27 27 m3/h (nominal) 1520 1520 1520 1520 1700 1700 1700 1700 2450 2450 2450 2450 2800 2800 2800 2800 m3/h (max.) (E) 1350 1250 1340 1250 1520 1460 1500 1460 2210 2110 2200 2110 2410 2350 2380 2350 m3/h (med.) (E) 1130 1060 1100 1060 1400 1360 1380 1360 1800 1730 1770 1730 2040 2000 2020 2000 m3/h (min.) (E) 790 750 780 750 1120 1060 1100 1060 1380 1340 1370 1340 1640 1600 1620 1600 Pa (nominal) 55 40 50 40 40 30 35 30 68 53 63 53 47 37 42 37 Pa (max.) (E) 72 70 70 70 58 56 56 56 75 75 75 75 69 69 69 69 Pa (med.) (E) 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 Pa (min.) (E) 24 25 24 25 32 32 32 32 30 30 30 30 32 32 32 32 (nominal) V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 (max.) (E) V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 V5 (med.) (E) V3 V3 V3 V3 V4 V4 V4 V4 V3 V3 V3 V3 V3 V3 V3 V3 (min.) (E) V1 V1 V1 V1 V2 V2 V2 V2 V1 V1 V1 V1 V1 V1 V1 V1 W (nominale) 238 242 240 242 283 281 282 281 376 376 376 376 411 411 411 411 W (max.) (E) 228 215 222 215 270 265 267 265 339 339 339 339 371 371 371 371 W (med.) (E) 182 175 178 175 232 229 230 229 268 268 268 268 285 285 285 285 W (min.) (E) 137 130 135 130 175 269 172 169 224 224 224 224 234 234 234 234 W A n 290 1,4 IP20 2 3/4 41 44 290 1,4 IP20 2 3/4 1/2 45,5 48,5 290 1,4 IP20 2 3/4 43 46 290 1,4 IP20 2 3/4 1/2 45,5 48,5 300 1,35 IP20 2 3/4 41 44 300 1,35 IP20 2 3/4 1/2 45,5 48,5 300 1,35 IP20 2 3/4 43 46 300 1,35 IP20 2 3/4 1/2 45,5 48,5 436 2,07 IP20 3 3/4 57 72 436 2,07 IP20 3 3/4 1/2 63 78 436 2,07 IP20 3 3/4 60 75 436 2,07 IP20 3 3/4 1/2 63 78 440 2 IP20 3 3/4 57 72 440 2 IP20 3 3/4 1/2 63 78 440 2 IP20 3 3/4 60 75 440 2 IP20 3 3/4 1/2 63 78

Water flow rate 70C (heating only coil circuit) 70C water pressure drop (heating only coil circuit) Heating capacity 50C

50C water pressure drop (main coil circuit)

Total cooling capacity

Sensitive cooling capacity

Water flow rate (cooling)

Water head loss (cooling)

Air flow rate

Useful static pressure (with filter installed)

Motor speed connections

Input power Maximum input power Maximum input current Number of fans Number of fans Coil connections (main)

Gas (Female) Coil connections (heating Gas (Female) only) Net Weight kg Gross Weight kg

The performance refers to the following conditions: (E) :Certificate Data in compliance with the Eurovent FCP Program - Electric power supply: 230V~50Hz - Class G3 air filter installed Cooling (Eurovent): - Inlet air temperature D.B. = 27C - Inlet air temperature W.B. = 19C - Water inlet temperature = 7C - Outlet water temperature = 12C - Water flow rate depending on the Dtw constant

- The nominal speed represents the upper limit of the air flow rate for which the heat exchanger has been dimensioned

Heating 50C (Eurovent): - Inlet air temperature D.B. = 20C - Inlet air temperature W.B. = 15C - Water inlet temperature = 50C - Water flow rate as in the cooling test

Heating 70C (Eurovent): - Inlet air temperature D.B. = 20C - Inlet air temperature W.B. = 15C - Water inlet temperature = 70C - Outlet water temperature = 60C - Water flow rate depending on the tw constant

54

737

440

16 275

Dimensional data (mm)


141
VED: 430 - 432 - 440 - 441 - 530 - 532 - 540 - 541

1104 1109 1158 1133


25 1053

20

403 362 313

10 300 15 256

130

45 109 241 198 16 275

737

440

141

1104 1109

VED: 630 - 632 - 640 - 641 - 730 - 732 - 740 - 741

150

25

40

1558 1533 1453

20

403 362 313


10

248 287

40

15

351 307

46 109
280 316

789 440

16
247 287 326
423 379 329

174

1504 1509
Code : SVEDUY.00 / 1101
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

55

Control panels
PXAE PXAI PXAR PTI

Control panels for fan coils


PXBI

KTLM

WMT05 WMT06

FMT10

PX2C6 PX2

WMT10

FMT21

NEW

TPF

NEW

Control panels
FMT10: Electronic thermostat for fan coils installed in 4-pipe and 2-pipe systems and in 2-pipe systems with electric heater, can be connected to two On/Off valves for closing coil water supply. Simplified controls with only 2 selectors for adjusting temperature and fan speed (3 speeds). External air sensor (supplied with sensor holder) to be placed inside the fan coil. Recessed installation. FMT21: Electronic thermostat with LCD for fan coils installed in 4-pipe systems, 2-pipe systems and systems with 2-pipes with resistance, with the possibility of connecting two On - Off type valves for the cut-off of the coil supply water. Probe for air temperature inside the panel. A room air temperature probe can be connected (SWA accessory). A probe for the temperature of the water in the system can be connected (SWA accessory). Recess installation. KTLM: Thermostat kit, including an IR remote control, an IR receiver, an electronic control board with air temperature sensor, a connecting cable, brackets and all the necessary mounting fittings. KTLM can be applied to fan coils installed in 2-pipe systems with or without water valves or in 4-pipe systems with water valves. For use with FCX fan coils with cabinet. KTLP: Thermostat kit, including an IR remote control, an IR receiver, an electronic control board with air temperature sensor, a connecting cable, brackets and all the necessary mounting fittings. KTLP can be applied to fan coils installed in 2-pipe systems with or without water valves or in 4-pipe systems with water valves. For use with FCX fan coils without cabinet. PCT2: Control panel with electromechanical thermostat for 2-pipe systems with thermostated ventilation. Not for use with FCA-R. Wall installation. PXBI: Simplified control panel with electronic room temperature thermostat. Mounted directly on the fan coil (for FCX AS, B, U and UA). PXAE : Electronic thermostat for fan coils installed in 2-pipe or 4-pipe systems. Simplified controls with only 2 selectors for adjusting temperature and fan speed (3 speeds, manual or automatic control). Can control 2 On/Off valves. Continuous or thermostated ventilation. Wall installation. PXAI : Electronic thermostat for fan coils installed in 2-pipe or 4-pipe systems. Simplified controls with only 2 selectors for adjusting temperature and fan speed (3 speeds, manual or automatic control). Can control 2 On/Off valves. Water temperature sensor included. Continuous or thermostated ventilation. Mounted directly on the fan coil (for FCX AS, B, U and UA). PXAR : Electronic thermostat for fan coils installed in 2-pipe systems, 2-pipe systems with electric heater or 4-pipe systems (without electric heater). Simplified controls with only 2 selectors for adjusting temperature and fan speed (3 speeds, manual or automatic control). The electric heater is controlled by the fan speed control. Can control the heater and one On/Off valve or, alternatively, 2 On/ Off valves. Continuous or thermostated ventilation. Water temperature sensor included. Wall installation or mounted directly on the fan coil (for FCX AS, B, U and UA). PTI: Control panel with electronic room temperature thermostat to be mounted directly on the fan coil (for FCX AS, B, U and UA). Mounting on the fan coil. PX: Control panel with switch. Wall installation. PX2: Control panel with switch. Wall installation or mounted directly on the fan coil (for FCX AS, B, U and UA). PX2C6: The control panel PX2C6 is provided only in multiple packages of 6 parts, sealed individually. Wall installation. TF1 : Room temperature thermostat with switch. Wall installation. WMT05: Electronic thermostat for fan coils installed in 2-pipe systems. The panel is electrically protected by an internal fuse. Thermostatically controlled ventilation, no control valve, wall installation. WMT06: Electronic thermostat for fan coils installed in 2-pipe or 4-pipe systems. The panel is electrically protected by an internal fuse.control of the thermostat valve, continuous ventilation, wall installation. WMT10: Electromechanical thermostat for fan coils installed in 4-pipe and 2-pipe systems and in 2-pipe systems with electric heater; can be connected to two On/Off valves for closing coil water supply. The panel is electrically protected by an internal fuse. Continuous or thermostated ventilation. Wall installation. TPF: Electronic thermostat with LCD display, for 2 and 4 tube fan coil units, with the possibility of connecting two valves of On-Off type for isolating the water supply to the coils. Air temperature sensor internal to the panel. It is possible to connect a system water temperature sensor (water sensor supplied loose). Recess mounted.

56

PXAE

PXAI

PXAR

PXBI

PTI

FMT10

FMT21

TPF

WMT05

WMT06

WMT10

KTLM

KTLP

TF1

PX

PX2

PX2C6

PCT2

Features Electronic thermostat Electromechanical thermostat Switch

Change over Automatic Manual

2,3m 2,5m 6m 2,3m 6m * *

2,3m

2,3m

Standard equipment Internal air sensor External air sensor Water sensor

2,5m

2,5m

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
6m 6m

Installation Wall installation On board installation Recessed installation (503) IR remote control

Configurations 2-pipe system 2-pipe system Without valve VCF SW** SA*** SIT SIT3 SIT5

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

2-pipe system with electric heater RX RX + VF SW3** SIT SIT3 SIT5

4-pipe system VC+VF SW3** SIT SIT3 SIT5

SIT3

SIT5

Important: Before choosing a control panel make sure it is compatible with the fan coil model and its accessories. Some control panels offer more functions than the standard configuration; consult the manual for information on all the functions available

Symbols * = Air temperature sensor selected by remote control ** = Water temperature sensor *** = Air temperature sensor VC = Hot water valve

VF = Cold water valve VCF = Hot and cold water valve RX = Electric heater (503) = Recessed 503 module

57

Cod.: SPCUY.06 / 1302

NEW

VMF
Zone interface

Variable Multi Flow system Range of components for the management of air conditioning, heating and domestic hot water systems

VMF systems central interface

Accessory module

VMF-E4D VMF-E4
*As awared by Chicago Athenaeum: Museum of the Architecture and Design

VMF-E5N / VMF-E5B

VMF-VOC

VMF-CRP

Zone interface

Thermostat with serial communication

Domestic water panel

VMF-E0

VMF-E1 / VMF-E18

VMF-E2 VMF-E2H

VMF-SW / VMF-SW1

VMF-ACS

* Winner for the International design Award "Good Design 2010" for the "Electronics"

Features
VMF: Variable Multi Flow system. Management and control system of hydronic systems for the conditioning, heating and production of domestic hot water. The VMF system allows complete control of every component of a hydronic system both locally and centrally and, communicating between the various components of the system, manages the performance without ever neglecting the end user's request of comfort, but reaching it as efficiently as possible with energy saving. If you add the advantages deriving from such an innovative control to the flexibility of a hidronic system, you get a more efficient and effective alternative to the variable refrigerant flow systems (VRF). The VMF system is extremely flexible, enough to allow various control and manage steps, expandable at different moments: 1) Control of a single fancoil. 2) Control of a microzone (one MASTER fancoil and a maximum of 5 SLAVE fancoils). 3) Control of multi independent zones system (one MASTER fancoil and a maximum of 5 SLAVE fancoils for each zone). 4) Control of a fancoil system, plus management of the heat pump (if compatible with the VMF system). 5) Control of a fancoil system, heat pump and management of the domestic hot water system (VMF-ACS). 6) Control of a fancoil system, heat pump, domestic hot water production and additional circulators (up to a maximum of 12 using three additional VMF-CRP modules). 7) Control of a fancoil system, heat pump, domestic hot water production, additional circulators and management of heat recovery units, maximum 3, (with the ability to handle up to 3 VMF-VOC sensors) or a boiler. The VMF system can operate and manage, through a VMF-E5N / VMF-E5B panel, a maximum of 64 zones consisting of a MASTER fancoil and a maximum of 5 SLAVE fancoils connected to each MASTER, for a total of 384 fancoils. Besides the central control supplied by theVMF-E5N / VMF-E5B panel, the MASTER fancoils must be provided with a local control interface; this interface can be mounted on the fancoil (VMF-E2 / VMF-E2H) or be mounted into a wall panel (VMF-E4). Different functions can be controlled through the VMF-E5N / VMF-E5B panel, including: - Identify the different zones setting a name for each one. - Check and set the ON-OFF function and the set temperature of each zone. - Set and manage the set temperature of the heat pump. - Scheduling time slots. Simple installation of the fancoil system through the SELF-MONITORING function of the MASTER fancoils.

58

System components
VMF-E0: thermostat accessory to fix on the side of the fancoil, equipped with air and water sensors as standard, controls 2 pipes, 4 pipes, 2 pipes + Plasmacluster, 2 pipes + UV lamps, 2 pipes + Electric heater systems. Equipped with external contact to be used as low voltage remote ON-OFF. This thermostat can create a single fancoil zone through 2-wire serial communication (1 master + 5 slaves maximum). The thermostat is fuse protected. VMF-E1: like VMF-E0 with extra: - Economy contact/presence sensor. - Auxiliary water sensor for general control in 4-tube systems (with VMF-SW1 accessory). - Serial RS485, protocol ModBus RTU, for centralised control. - Possibility to insert expansion cards for future development. The VMF-E1 accessory must therefore be used in the Masters in the presence of multiple zones, or for communication with the chiller/heat pump. VMF-E18: the same as the VMF-E1, but for fancoils with inverter motors. VMF-E2: this is the user interface on the machine to match to the VMF-E0, VMF-E1 and E18 accessories for the series UL-S-FCXAS, FCX-U (sizes 62-64-82-84-102) FCX180U FHX-U (sizes 62-82). Equipped with 2 selector switches, one for temperature and one for speed control. VMF-E2D: is the user interface (as above) on the machine, to combine with accessories VMF and VMF-E0-E1, dedicated to the series DUALJET. VMF-E2H: this is the User Interface (as above) on the machine, to match to the VMF-E0, E1, accessories dedicated to the HL series VMF-E4: this is the wall mounted user interface, to match to the VMF-E0, VMF-E1 and VMF-E18 accessories for the UL, HL, and FCX series without on-board control. Innovative design, extremely slim and inexpensive, allows control of functions via a capacitive touch keypad with LCD display. The environment can be adjusted with the sensor on the panel (standard), or the sensor of the fancoil which it is connected to, or by their arithmetic mean. It also allows the activa t i on o f t h e a i r p u r i f i e r a c c e sso r y (Plasmacluster / UV Lamp) and the electrical heating element. VMF-E4D:is the variant of the previous code, but with frontal gray Pantone 425C (METAL) VMF-E5B: white recessed panel, with backlit graphic LCD and capacitive keyboard allows the centralised command/control of a complete hydronic system consisting of Fancoils: up to 64 fancoil zones consisting of a master + 5 slaves. Chiller/heat pump equipped with Modu_Control, GR3 and pCO2/PCO controls (accessory required for RS 485 interface with MODU-485A, AER485, AER485P2 / AER485P1); circulators: up to 12 configurable zone circulators; boiler: boiler consensus management for hot water production; heat recovery units: consents up to 3 per programmable recovery units based on the timing and/or by measuring the air quality obtained with the VMF-VOC accessory; domestic water module: complete management of the domestic hot water production through the control of: diverting/circulator valve, integrated resistor, accumulation temperature sensor, antilegionella circuit. VMF-E5N: this is the variant of the previous code, but with black plastic. VMF-VOC : accessories for measuring air quality (see related point in the description of the VMF-E5B). VMF-CRP: accessory module for the control of the boilers, pumps and heat recovery units. VMF-SIT3: Interface cards that allow you to connect
the thermostats VMF and VMF-E0-E1 to a fan motor with high power (for selection see all the documentation of the thermostat and the fan coil).

thermostats for the maximum control in the cold range. VMF-ACS3KM: electrical panel for the complete command/control for hot water storage (3-way control valve, integrated single phase 3kW resistor command, Anti-legionella and temperature sensor). VMF-ACS3KTN: electrical panel for the complete command/control for hot water storage (3-way control valve, integrated three-phase 3kW resistor command, Anti-legionella and temperature sensor). VMF-ACS6KTN: electrical panel for the complete command/control for hot water storage (3-way control valve, integrated three phase 6kW resistor command, Anti-legionella and temperature sensor). VMF-ACS8KTN: electrical panel for the complete command/control for hot water storage (3-way control valve, integrated three phase 8kW resistor command, Anti-legionella and temperature sensor). GLL_N: FCL_N grid units, equipped with thermostat card for serial communication with the accessory functions equivalent and VMFE1 (this grid is a mandatory accessory for the units FCL N); GLLI_N: FCLI_N grid units, equipped with thermostat card for serial communication with the accessory functions equivalent and VMF-E18, (this grid is a mandatory accessory for the units FCLI N);

VMF-SW: water sensor may be used in place of the standard supplied with VMF-E0, VMFE1 and VMF-E18 thermostats for the installation upstream of the valve. VMF-SW1: additional water sensor may be used for 4-pipe systems with VMF-E1 and E18

Dimensions (mm)

VMF-E5B / VMF-E5N VMF-E4 / VMF-E4D VMF-ACS VMF-VOC VMF-E5B / VMF-E5N

A B C [mm] [mm] [mm] 138 110 45 125 80 11 354 544 135 79 81 26

VMF-E4 / VMF-E4D

VMF-ACS

VMF-VOC

59

Selection 1 Compatibility of thermostats for serial communication and control interface for MASTER units
Models FCX FCXI HL UL FHX Versions AS - UA - B U P - PPC - PO - PV AS U P S - SM N S P UV UVP - UVPO Notes (7) (7) (1) (7) (8) (8) VMF-E0 VMF-E1 VMF-E18 VMF-E2 VMF-E2D VMF-E2H VMF-E4 / VMF-E4D GLL N GLLI N -

VEC FCL FCLI VED FCW N DUALJET

Selection 2 Compatibility of VMF-E5 7 VMF-E5B centralised control


Models FCX FCXI HL UL FHX VEC FCL FCLI VED FCW DUALJET Versions AS - U - UA - B P - PPC - PO - PV AS - U - P S - SM N S P UV - UVP - UVPO Notes (2) (2) (2) (2) (1) (2) (2) (2) (2) (2) (2) (2) (2) (2) VMF-E5N / VMF-E5B

Selection 3 Compatibility of heat pumps with electrical panel for domestic hot water management
Models ANL ANLI ANK ANR ANF SRA SRP-V1 NRL NRC WSH Versions H Tutte Tutte H H Tutte Tutte H H Tutte Notes (3) (4) (4) (4) (3) (4) (3) (4) (4) (4) (3) (4) (3) (4) (4) VMF-ACS3KM VMF-ACS3KT VMF-ACS6KT VMF-ACS8KT

Selection 4 Compatibility of modules and additional sensors


Models VMF-E5N/ E5D VED RePuro Versions Tutte Tutte Notes (5) (6) (9) (5) (6) VMF-CRP VMF-VOC (6) (6) VMF-SIT3

Notes: The versions with the accessories hanging MA or MP, can be treated equally to their respective versions FCX AS U FCX, FCX AU; (1) This version includes the thermostat E0-VMF and VMF-E2H command interface already installed, these features make these models suitable for operation as a single unit or function of the MASTER microzone plants (plants consist of a single zone, without centralized contol VMF-E5N / VMF-E5B); (2) To be compatible with the centralized control of VMF-E5N / VMF-E5B, a fan must be set as MASTER of the area, therefore this must be equipped with the thermostat for serial communications, or VMF VMF-E1-E18 and combined with a user interface ( VMF-E2, or VMF VMF-E2H-E4), or units FCL / FCLI equipped with a thermostat on the grid GLL_N / GLLI_N, combined with a command interface VMF-E4 / VMF-E4D ; (3) The heat pumps with integrated storage are not suitable for production of hot water; (4) To know the maximum temperature of hot water production (plant and / or health) refer to the limits on the operating unit technical manual; (5) All types of systems that provide centralized control of VMF-E5N / VMF-E5B, are compatible with the accessory modules (maximum 4) VMF-CRP, and each module can function as a pump controller (4 for each accessory module) or boiler control and recovery (with ON / OFF control and management of 3 recovery boiler in addition to 3 accessories VMF-VOC); (6) The compatibility of the probe VMF-VOC is only related to the presence of the accessory module in the system with VMF-CRP control function recovery; (7) VMF-E2: Only for size FCX62U-64U-82U -84U-102U, FCXI80U, FHX62UV-82UV. (8) units must be included in boxes FCLI GLLI_N mandatory accessory grid, this grid is equipped with a card thermostat same rights as VMF-E18 models. FCL cassette units must provide the mandatory accessory GLL_N grid, this grid is equipped with a card equivalent and thermostat models VMF-E1. To use one of these drives as MASTER is necessary to provide the command interface VMF-E4; (9) Accessory units required for the combination of VED with thermostats or VMF VMF-E0-E1. Using a VMF-SIT3 for each unit;

60

Example of system components


VMF-CRP
A maximum number of 4 VMF-CRP modules can be installed and each one can perform seveVOC n1 n2 ral tasks based on the type of setting: - Control 4 pumps VOC - Control 3 heat recovery units and 3 VOC senn3 n4 case the correct n3 number n4 of VMFsors (in this VOC accessories must be purchased) VOC - Control a boiler The only requirement to install VMF-CRP modules is the presence of a VMF-E5 centralised control

n1 n2 n3 n4 n3
n1

n2 n4
n2 n4

VOC VOC VOC VOC


VOC VOC

-CRP n2

n1

Selection 4:

VMF-CRP n1 x3 n2 n3 n4

x3

n3

VMF-ACS
VMF-ACS

x3
Selection 3:

VMF-ACS

The VMF-ACS accessory allows to control the different components needed to produce domestic hot water; for detailed information on the types of systems manageable by VMF-ACS, refer to technical documentation of the accessory WARNING: in the case where the plant is provided with accessory Multicontrol it will not be possible to use the accessory VMF-ACS, since the production of domestic hot water will be controled only through VMF-E5 the accessory Multicontrol.

Multicontrol

VMF-CRP (Multicontrol) n1 n2 n3

Chiller

VMF-E5

WARNING:: Each chiller must be provided with the appropriate communications accessory Modu-485A

Selection 2:

MODbus RS485 (MAX 1000m)


Chiller

Chiller 1 (Multicontrol)

Chiller 4 (Multicontrol)

VMF-E4
MODbus RS485 (MAX 1000m) VMF-E4 RS-485

RS-485 VMF-E4

RS-485

B Fancoil 1 A (MASTER) Fancoil 1 (Slave) Fancoil 2 (Slave)


MAX 30m (ModBus TTL)

Fancoil 1 A (MASTER) MODbus RS485 Multicontrol Fancoil 1 (Slave)


VMF-E4

Fancoil 64 (max) A (MASTER) Fancoil 1 (Slave) Selection 1: Fancoil 2 (Slave)

MAX 30m (ModBus TTL)

Fancoil 64 (max) A (MASTER) VMF-E4 A A A A A ModBus TTL

A A

A ModBus TTL A A A A

Fancoil 1 (Slave) A
Fancoil 1 A A (MASTER) B Fancoil 2 (Slave)

Fancoil 2 (Slave) Fancoil 3 (Slave)


B

Fancoil 64 (max) A Fancoil 3 (Slave) A (MASTER) A A A A A

Fancoil 3 (Slave) Fancoil 4 (Slave) Fancoil 5 (max) (Slave)

A 1 (Slave) Fancoil 4 (Slave) A(Slave) Fancoil Fancoil 3


ModBus TTL A A Fancoil 2 Fancoil (Slave) 5 (max) (Slave) Fancoil 4 (Slave) A Fancoil 3 (Slave)

A Fancoil 1 (Slave) Fancoil 4 (Slave) A Fancoil 2 (Slave) Fancoil 5 (max) (Slave)


Fancoil 3 (Slave) Fancoil 4 (Slave) Fancoil 5 (max) (Slave)
Cod.: SVMFUY.06 / 1301

Fancoil 5 (max) (Slave) A Fancoil 4 (Slave)


A Fancoil 5 (max) (Slave)

A
B

A
B

Thermostat for serial connection VMF-E0 / VMF-E1 / VMF-E18

A
B

Commands interface for MASTER unit VMF-E2 / VMF-E2H / VMF-E4

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

61

Climafon

Thermoconvectors Vertical installation residential use

With fixed grille (Version G)

With Manual Blade (Version M)

With Automatic Blade (Version A)

Aermec presents the brand new natural convection heating system in the CLIMAFON system. CLIMAFON is born from long experience in the heat exchange field gained within the Giordano Riello International Group, a group in which Aermec is the leading company. CLIMAFON is a system terminal that works on the basis of natural convection: the air is heated through an exclusive finned exchange and is sent into the room through a flue effect.

Features
Enhanced Comfort: CLIMAFON heats rooms content. This enables it to be very fast in heapleted. Costly masonry work typical of radiaquickly and naturally because it basis its opeting times and permits it to be used only tor installation is avoided: just four blocks are ration on air moved by simple convection. where it is useful. The speed it takes required for fixing CLIMAFON to the wall. The use of CLIMAFON with low temperature CLIMAFON to reach full capacity operation Electronic regulation: CLIMAFON, in its heating systems (heat pump, condensation has been checked by TV (world leader in complete version, has a built in thermostat boiler, geothermal and solar...) ensures that product assessment and verification). with temperature that can be regulated by the the rooms are heated without drying the air. Greater security: CLIMAFON's outer surface user. The thermostat controls an interior It causes a pleasant sensation of well-being reaches a top temperature of 43C, a value motor that opens and closes the deflector that helps to survive even the longest and that is totally harmless for our body (the risk interrupting the supply of heat. This system is harshest winters in total relaxation. of burning is nil). Its rounded form without powered by a normal 9 volt battery (a life of Best quality of the air we breath: the air temsharp edges makes the room a safer enviup to three years operation before replaceperature of the air leaving CLIMAFON is such ronment especially for children. ment is necessary) that makes CLIMAFON as not to allow the toasting of the powder in Greater care to appearance: the soft flowing, completely autonomous without the need for the environment. The result is healthy, clean modern and elegant lines give CLIMAFON connection to the mains. air. In addition to our health, winners also greater appeal that enables it to be integrated include the walls of our house (CLIMAFON with all types of furnishing whether it is tradispells the end to the blackening of walls typitional or modern. cal of radiator systems). Easier and faster installation: CLIMAFON is Energy saving: the innovative finned exchanmuch lighter than a radiator with the same ger ensures high energy efficiency thanks the capacity; just one person is needed to handle possibility of effective use at low temperatuand install it quickly and easily on all types of res of the warm supply water. wall. CLIMAFON is fitted with an installation Operation at full capacity achieved more template that means the unit can be assemquickly: CLIMAFON has much smaller water bled after the building work has been com-

62

Versions
Available in four sizes. Available versions with fixed grille, manual fin or motorised fin. For the last version, in order to avoid the creation of an electrical system, the unit is controlled by a normal 9V battery (life of up to three years of operation before replacement is necessary). The versions available are single coil (2 rows of pipes), double (4 rows of pipes) or treble (6 rows of pipes). Treble coil

Double coil

Single coil

Selection
By combining the various options, each model can be configured. Code: CLIMAFON Size : 1, 2, 3, 4 Coil : 1 - Single 2 - Double 3 - Treble Commercial code example: CLIMAFON 23M This is the Climafon unit, size 2 with treble coil and manual blade. Grille: G - With fixed grille M - With manual blade A - With motorised blade

Technical data
Mod. Climafon Heating capacity Water flow rate Water pressure drop Water contents Coil connections Rows of pipes W l/h kPa l 11 700 60 0,18 0,4 1/2 1 12 910 78 0,22 0,5 1/2 2 13 1005 87 0,26 0,6 1/2 3 21 1010 87 0,24 0,5 1/2 1 22 1350 116 0,50 0,8 1/2 2 23 1540 135 0,72 1,1 1/2 3 31 1400 120 0,35 0,6 1/2 1 32 1750 150 0,95 1,0 1/2 2 33 2001 176 1,36 1,4 1/2 3 41 1810 156 0,52 0,7 1/2 1 42 2205 190 1,31 1,1 1/2 2 43 2515 221 1,91 1,6 1/2 3

Performance values refer to the following conditions: Heating (in accordance with UNI EN 442): - room air temperature 20 C; - water inlet temperature 75-65 C; Dt water 50 C.

Dimensions (mm)

Mod Climafon Height Width Depth Weight

A B C [kg]

11 675 600 140 11,6

12 675 600 140 12,1

13 675 600 140 12,5

21 675 800 140 14,2

22 675 800 140 14,9

23 675 800 140 15,6

31 675 1000 140 17,1

32 675 1000 140 18

33 675 1000 140 18,7

41 675 1200 140 19,9

42 675 1200 140 21

43 675 1200 140 21,9

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

63

Cod.: SCFONUY.00 / 0503

Climabox

Recessed wall-mounted convection heater

Climabox is the innovative built-in wall convection radiator for heating systems. It was created to meet the needs for space rationalization according to modern architecture criteria for interiors and the current need for energy saving.
Characteristics
Available in 3 sizes with double or triple battery. Climabox consists of several parts to be assembled: 1. Frame in galvanized and painted plate that allows the heat exchanger to be installed in the wall. 2. Heat exchanger , designed for maximum intensification of the natural convection effect, constructed of copper piping and finning. 3. Closing panel supplied, which allows the materials, desired look and colour of the panel to be customized. Once the work is complete, the heating unit will be completely hidden from view. 4. Head Located on the upper horizontal part of the panel, it is available with a fixed metallic grille. The closing panel and all of the visible parts of the frame are treated so they can be painted with the same paint as the wall. The Climabox convection heater is the ideal terminal for heating any room. Heat is supplied instantly and uniformly distributed throughout the area. It can be added to a heating system powered by a boiler, district heating system or heat pump. The possibility of easily removing the cover allows for thorough cleaning of the interior. Ease of installation with reversable water attachments in the installation phase. Full compliance with safety and injury prevention regulations

Head

Frame in galvanized plate

closing panel

Heat exchange battery

Unit choice
Any model can be configured by changing the available options. Logo: CLIMABOX Size: 2, 3, 4 Battery: 2 - Double 3 - Triple Grille: Fixed grille

64

Technical data
Mod. Thermal power Water flow rate Water pressure drop Water content Battery connectors CBX 22 1220 105 0,5 0,8 CBX 23 1330 114 0,72 1,1 CBX 32 1610 138 0,95 1 1/2" Female CBX 33 1755 151 1,36 1,4 CBX 42 2005 172 1,31 1,1 CBX 43 2180 187 1,91 1,6

W l/h kPa l gas

Data in compliance with standard UNI EN 442 HEATING Water input temperature Water output temperature room temperature

75 C 65 C 20 C (T0=50 C)

Dimensions (mm)

Exchanger width

mm

625

625

825

825

1025

1025

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Fax 044293730 www.aermec.com

65

Cod.: SCBXUY.01 / 1203

CHF Height Width

A A

mm mm

22 155 884

23 155 884

32 155 1084

33 155 1084

42 155 1284

43 155 1284

TUN

Ductable air-conditioning unit

UNIVERSAL CONFIGURATION VERSION WITH 4-6 ROW COIL VERSION WITH EXTRACTOR
Features
The air-conditioning units of the TUN series are intended for civil, commercial and hotel systems in small to medium sized environments. They are distinguished by their compactness (a necessary requisite for false ceiling applications) and low noise. The wide range of accessories meets various system requirements The structure is made of 1.5 mm thick hot galvanised sheet metal, insulated internally with a V0 insulation class. The unit is designed for any flow and/or intake channels to be connected. The unit can be installed horizontally or vertically and both are facilitated by the relative brackets. Air-filtering relies on standard G2 class filters in accordance with EN779 (6 mm thick), positioned on intake. Forward blade double intake centrifugal fans with a directly coupled motor. The single-phase 230V-50Hz multi-speed motor has three speeds that are selected via a control. Internal condensate drip tray made of 1 mm thick hot galvanised sheet metal. 4-6 row coils, powered with hot or cold water and made of copper piping with aluminium louvered fins blocked by mechanical expansion of the pipes. The threaded sleeves for the hydraulic connections and the air bleeding valve are supplied. The coils can be rotated on site. Post-heating 2-row coils are also available, made of copper piping with aluminium louvered fins blocked by mechanical expansion of the pipes.

Choosing the unit


By appropriately combining the variety of options available, it is possible to configure every model in a manner that satisfies all specific implant requirements.

Fields configurator:
1 2 3 4 5 6 7 | | | | Code | Version | | | Size Configuration

Identication: TUN Size: 10, 15, 20, 25, 40 Version: 4 - 4 row coil 6 - 6 row coil Configuration: P - Powered X - Extractor

Example of a sale code: TUN104P This is a TUN unit, size 10 with a powered 4-row coil.

66

Accessories
M2S Mixing chamber 2 dampers Section made of galvanised steel sheet with two air calibration dampers and louvers made of galvanised sheet steel. 50 mm louver pitch; 8 mm motorised regulation pin made of galvanised steel. M3S Mixing chamber 3 dampers Section made of galvanised steel sheet with three air calibration dampers and louvers made of galvanised sheet steel. 50 mm louver pitch; 8 mm motorised regulation pins made of galvanised steel. It must be coupled with the VRF accessory. FTF Soft bag filter section Section made of galvanised steel sheet with F6 filtering degree soft bag filters. For different filtering degrees please contact the Aermec Sales Technical Dept. It must be coupled with a powered unit. made of galvanised steel. VRF Return ventilating section with a G4 filter Ventilating unit equipped with an electronic rev shifter, contained in a galvanised steel sheet section with flat filters having a G4 efficiency (EN779). PMM Plenum with circular flow attachments 1.5 mm Plenum made of hot galvanised sheet metal. The plenum has multi-diameter circular plastic fittings (200 mm, 180 mm and 150 mm) for circular pipes to be connected. TPMC Plenum of delivery Plenum to be used for the connection with circular canals. Made of galvanized steel with insulating mat with circular nozzles Three sections closed. It can be used as a plenum, both as a plenum aspiration with circular channels. FPI G4 filters for lower intake FPF G4 filters PX Control panel with only the switch-over WMT 05 Electro-mechanical thermostat For fan coils installed in 2-pipe systems. The panel must be installed on the wall and protected electrically with an internal fuse. It has the following functions: on / off switch; cursor to select the heating / cooling modes (manual season change); cursor to select the fan speed (high, medium and low); temperature selector (+5C to 30C) WMT 10 Control panel For fan coils installed on the wall. Controls the fan coil operation according to the set mode. The panel must be wall mounted; it is to be used in 4-pipe and 2-pipe systems and systems with 2-pipes with resistance, with the possibility of connecting two ON - OFF type valves for the cut-off of the coil supply water. The panel is protected electrically by an internal fuse. The control has the following functions: 1) cursor to select the cooling or heating mode; 2) manual season change; 3) manual selection of the fan speed; 4) selection of the desired room temperature (+ 10C to 30C); 5) 2-pipe system management; 6) 4-pipe system management; 7) 2-pipe system management (cooling) + electrical resistance (heating); 8) thermostatic ventilation; 9) continuous ventilation; 10) continuous ventilation in cooling mode and thermostatic in heating mode.

PMC Closed flow plenum 1.5 mm Plenum made of hot galvanised sheet B2R 2 row water coil metal. The plenum allows the flow to turn 90. For 4-pipe systems, positioned internally, The installer must make the flow downstream the main coil. The threaded sleeves for the hydraulic connections and the air aperture. bleeding valve are supplied. SAS Intake damper Air calibration damper with louvers made of PBE Section with post-heating coil galvanised sheet steel. 50 mm louver pitch; 8 The electric coil consists of armoured mm motorised regulation pin made of resistances fitted with a twin safety galvanised steel. thermostat. SSL Module with silencer baffles Section made of galvanised steel sheet with mineral wool silencer baffles covered in a polyethylene film in order to prevent flaking. S2Z 2-area damper (70-30%) Damper made of galvanised steel sheet with opposite louvers for the external air flow to blend with the air circulation flow. 50 mm louver pitch; 8 mm motorised regulation pin GMD Flow grid with adjustable louvers Grid with double row adjustable louvers for air to be introduced in the relative room. It can be installed directly on to the appliance by removing the flanges or on to the wall. GAP Intake grid With louvers tilted at 45; it can be installed directly on to the appliance by removing the flanges or on to the wall.

M2S M3S FTF B2R PBE SSL S2Z VRF PMM TPMC PMC SAS GMD GAP FPI FPF PX WMT 05 WMT 10

TUN 10 M2S1 M3S1 FTF1 B2R11 PBE1 SSL1 S2Z1 VRF1 PMM1 TMPC1 PMC1 SAS1 GMD1 GAP1 FPI1

TUN 15 M2S2 M3S2 FTF2 B2R21 PBE3 SSL2 S2Z2 VRF3 PMM2 TMPC2 PMC2 SAS2 GMD2 GAP2 FPI2 (1) (1)

Accessories compatibility TUN 20 M2S3 M3S3 FTF3 B2R31 PBE4 SSL3 S2Z3 VRF4 PMM3 TMPC3 PMC3 SAS3 GMD3 GAP3 FPI3 (1) (1)

TUN 25 M2S4 M3S4 FTF4 B2R41 PBE5 SSL4 S2Z4 VRF5 PMM4 TMPC4 PMC4 SAS4 GMD4 GAP4 FPI4 (1) (1)

TUN 40 M2S4 M3S4 FTF4 B2R41 PBE6 SSL4 S2Z4 VRF6 PMM4 TMPC4 PMC4 SAS4 GMD4 GAP4 FPI4 (2) (2) (2)

TUN 40P M2S5 M3S5 FTF5 B2R51 PBE7 SSL5 S2Z5 VRF7 PMM5 TMPC5 PMC5 SAS5 GMD5 GAP5 FPI5 (2) (2) (2)

(1) SIT3 is to be used and the 2A fuse is to be replaced with a 4A fuse (2) Install a replay, one per speed

67

Technical data
10 Cooling capacity with: 4-row coil (1) 6-row coil
(1)

15 9,3 6,6 11,1 7,6 1599 1910 16 34 19 21,1 9,3 10,5 1663 1849 13 24 11,7 1026 7 8 2

20 12,5 8,7 14,1 9,8 2141 2420 33 20 24,9 27,5 12,1 13,6 2183 2410 24 15 15,3 1339 7 10 2

25 16,5 11,4 18,5 12,7 2832 3184 33 20 32,3 35,4 16 17,6 2831 3101 24 14 20,5 1792 10 12 2 400V/3/50Hz 2500 150 874 3,8 4 230V/1/50Hz G2/G4 F6 78 1 "

40 23,3 16,3 26,6 18,5 4002 4572 60 37 46,7 52,2 25,9 28,9 4089 4573 46 28 27,9 2444 17 20 2

10P 4,7 3,6 6,2 4,4 804 1072 3 9 16,6 18,5 6,4 7,2 978 1097 4 7 7 609 4 6 2

40P 26,4 18,2 29,4 20,1 4536 5051 56 28 51,1 56,1 30,8 34,8 4475 4909 41 20 31,8 2786 10 20 2

total sensible total sensible

kW kW kW kW l/h l/h kPa kPa kW kW kW kW kW l/h l/h kPa kPa kW l/h kPa kW n

4,7 3,6 6,2 4,4 804 1072 3 9 11,2 12,5 5,5 6,1 978 1097 4 7 7 609 4 4 2

Water ow rate 4-row coil 6-row coil Pressure drop 4-row coil (2) 6-row coil (2) Heating capacity with 4-row coil (2) 6-row coil (2) 4-row coil 6-row coil Water ow rate 4-row coil 6-row coil Pressure drop 4-row coil 6-row coil Heating capacity 2-row water coil Water ow rate Pressure drop Electrial coil: Electric coil capacity No. of stages of the electric coil Power supply fan: Air ow rate (3) Static pressure Fan input current Fan power supply Poles Power supply Filters: Efciency of at lters (4) std/opt Efciency of bag lters Sound data: Sound power Hydraulic connections: Main coil collectors Additional coil

total total total total

m3/h Pa W A n

900 110 357 1,6 2

1500 150 713 3,1 2

2000 170 886 3,9 4

4000 120 1771 7,7 4

900 330 713 3,1 2

4000 220 1771 7,7 4

STD/OPT

G2/G4 F6 dB(A) 68 1 "

G2/G4 F6 72 1 "

G2/G4 F6 77 1 "

G2/G4 F6 79 1 "

G2/G4 F6 71 1 "

G2/G4 F6 80 1 "

(1) Temperature of incoming air Water temperature inlet Water temperature outlet (2) Temperature of incoming air Water temperature inlet Water temperature outlet

27C b.s.|19C b.u. 7C 12C 20C 70C 60C

(3) At nominal flow rate with 4-row coil (4) In compliance with EN 779

68

Dimensional data (mm)

C B

TUN HORIZONTAL INSTALLATION WITH EXTRACTOR Mod. TUN 10 10P 15 DIMENSIONS OF A HORIZONTAL INSTALLATION AND "EXTRACTOR" CONFIGURATION Height (A) mm 300 300 300 Width (B) mm 700 700 1050 Length (C) mm 700 700 700 Connection projection mm 82 82 82 Number of fans n 1 2 2 UNIT NET WEIGHTS 4-row coil 6-row coil 10 33 35 10P 37 38 15 47 49 20 390 1050 850 82 1 20 59 61 25 390 1475 850 82 1 25 88 92 40 390 1475 850 82 2 40 88 92 40P 390 2100 1000 82 2 40P 108 108

kg kg

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

69

Cod.: STUNUY.06 / 1211

TS

Air handling units with cooling capacity from 4.85 up to 24.8 kW

TSMX TS TSBA TSPM gal fans Wide range of accessories to meet varying Three-speed electrical motor with running needs (class G3 air filter, post-heating coils, capacitor permanently activated and internal plenum suction assembly, mixer section, sucthermal protection tion grille, delivery flanges with circular Transmission system relay card for each speed outlets or rectangular outlet) (excluding the models TS13 and TS16) Useful static pressure available for any canalisation Large choice of distance commands

Characteristics
Compact unit for horizontal installation Structure made of Aluzink sheet steel and internally covered with sheets of polyethylene and polyester to obtain improved thermal and acoustic insulation Condensate drip tray in stainless steel AISI 304 with insulation Coils with aluminium fins and copper pipes Statically and dynamically balanced centrifu-

Choice of Unit
By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system requirements. Code: Models Field configurer: TS 1 2 3 4 available: | | | Size: Code | | TS 13 1, 2, 3, 4, 5, 6, 7 | Size | TS 16 Coil: | | Row coil TS 23 3 - 3-row coil | | | TS 34 TS 1 2 3 4 5 6 7 3 4 6 4 - 4-row coil TS 36 TS 43 6 - 6-row coil

Example of the commercial code: TS34 This is a TS unit, size 3, with 4-row coil.

TS 46 TS 53 TS 56 TS 63 TS 74 TS 76

Accessories
TSBA: 2-row coil for post-heating, contained in which the TSGA grille can be applied the connector (W) of the FMT21 panel. Two a delivery installation plenum TSPM: Delivery plenum to be connected to the SWA probes can be connected simultaneously TSFA: Class G3 air filter circular channels (with 2, 3 or 4 circular, 200 to the FMT21 panel. TSFM: Delivery flange with rectangular section mm flanges). Control panels:the characteristics of the control TSGA: Horizontal suction grille with fixed fins SWA: External probe accessory SWA (length L = panels are described on the appropriate card. to produce suction from below together with 6m). It detects the temperature of the room air if the TSPA accessory connected to the connector (A) of the FMT21 TSMX: Section that mixes the recirculating air panel. The room air temperature probe, incorand the external air. Calibration of the mix via porated in the panel, is automatically disabled. the damper, motorisation is possible It detects the temperature of the water in the TSPA: Plenum with suction from below, to system for ventilation consent if connected to
TSPA TSMX TSFA

TS

TSRD TSRS

TSBA

TSFM

TSPM

TSGA

AIR AIR

AIR

70

Technical data
Model Cooling capacity Sensible cooling capacity Water side pressure drop Water flow rate Heating capacity Water side pressure drop Water flow rate Nominal air flow rate Useful static pressure (1) TSFA filter pressure drop (2) Coil rows Coil water connections Maximum water temperature Ventilation speed number Motors Fans Ventilation speed number Motors Motor maximum power Maximum input current Sound pressure level U.M. kW kW kPa l/h kW kPa l/h m3/h Pa Pa n. C bar n. n. W A dB(A) TS 13 4.85 3.75 21 830 9.80 12 840 930 90 13 3 G 3/4" 120 15 1 3 1 90 1 50 TS 16 5.80 4.45 9 1000 12.58 8 1080 930 55 13 6 G 1" 120 15 1 3 1 90 1 50 TS 23 7.9 6.4 24 1360 15.50 17 1330 1500 100 11 3 G 3/4" 120 15 2 3 1 147 1,9 51 TS 34 9.6 7.6 24 1650 19.70 20 1690 1600 85 12 4 G 3/4" 120 15 2 3 1 147 1,9 52 TS 36 10.5 8.3 16 1810 21.52 13 1850 1600 45 12 6 G 1" 120 15 2 3 1 147 1,9 52 TS 43 11.1 8.95 23 1910 21.60 17 1860 2050 115 13 3 G 3/4" 120 15 2 3 1 184 2,6 55 TS 46 13.3 10.7 17 2290 27.49 13 2360 2050 80 13 6 G 1" 120 15 2 3 1 184 2,6 55 TS 53 13.9 9.8 32 2390 25.90 21 2230 2400 105 11 3 G 3/4" 120 15 2 3 1 184 2,6 55 TS 56 16.5 11.7 27 2840 32.89 21 2830 2400 70 11 6 G 1" 120 15 2 3 1 184 2,6 55 TS 63 16.6 13.1 26 2860 35.50 20 3050 3600 120 16 3 G 1" 120 15 2 3 1 420 3,9 58 TS 74 21.9 17.8 28 3770 46.30 23 3980 4200 115 25 4 G 1" 120 15 2 3 1 600 5,5 58 TS 76 24.8 20.1 26 4270 52.06 21 4480 4200 75 25 6 G 1" 120 15 2 3 1 600 5,5 58

Power supply = 230V ~ 50Hz. Performance values refer to the following conditions: (1) rated capacity (maximum speed) without air filter; (2) air filter (TSFA accessory) at rated capacity; Cooling: - Internal air temperature 27C B.S. ; 19C B.U. - Water inlet temperature 7C ; - t = 5C

Heating: - Internal air temperature 20C - Water inlet temperature 70C - t = 10C

Compatibility of accessories TS TSBAx TSFAx TSFMx TSGAx TSMXx TSPAx TSPMx FMT10 PXAE WMT SWA** 10 10 10 10 10 10 10 10 05 20/30 20/30 20/30 20/40 20/30 20/30 20/30 20AW 10 40 40 40 40 40 40 50 50 50 50/60/70 50 50 50 60/70 60/70 60/70 60/70 60/70 60/70 13 - 16 * * * * * * * (x 1-2) 23 * * * * * * * (x 1-2) 34 - 36 * * * * * * * (x 1-2) 43 - 46 * * * * * * * (x 1-2) 53 - 56 * * * * * * * (x 1-2) 63 * * * * * * * (x 1-2) 74 - 76 * * * * * * * (x 1-2)

* = The code of these accessories is obtained by substituting the letter x with the number indicating the corresponding size of the unit ** = SWA accessories are matched with FMT21 control panels.

Dimensions (mm)

TS13 TS16 TS23 TS34 TS36 TS43 TS46 TS53 TS56 TS63 TS74 TS76 Height (A) [mm] 296 296 296 296 296 325 325 325 325 375 375 375 Width (B) [mm] 645 645 1000 1000 1000 1100 1100 1345 1345 1345 1345 1345 Depth (C) [mm] 520 520 520 520 520 600 600 600 600 600 600 600 Weight [kg] 25 27 35 38 42 42 46 48 52 56 61 67,5
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

71

Cod.: STS1UY.03 / 1302

TDA

Air handling units Air flow rate from 800 to 3,500 cu.m/h

HORIZONTAL OR VERTICAL INSTALLATION VERSION WITH 3-4 ROW WATER-TYPE COIL VERSION WITH 2-ROW DIRECT EXPANSION COIL VERSION WITH EXTRACTOR
Characteristics
The conditioning units in the TDA range have been designed for small and medium sized rooms in civil, commercial and hotel type systems. The units are designed to guarantee high head levels and are suitable for both vertical and horizontal installation, to ensure greater versatility of use. The outstanding aesthetic finish of the product makes it perfect for installation in box rooms, bathrooms, suspended ceilings or in the room itself. The wide range of sizes and accessories available means it's easy to choose the best model for the specific requirements. Structure with hot galvanised steel sandwich panels, 15mm thick, with interposed polyurethane foam (density 40kg/m3). The delivery and suction panels are equipped with flanges for the collets to any air channels and can be moved to create different air flow configurations. The horizontal or vertical fixing to the walls of the unit is made possible by the appropriate brackets. New centrifugal fans with high head levels, double suction, forward blades and directly coupled motor. The single-phase 230V-50Hz motor is multi-speed (of which three speeds can be selected). Condensated collection basin in galvanised steel, suitable for both vertical and horizontal installation. Coils with 3 rows, that can be fed with hot or refrigerated water. Made of copper pipes with aluminium finning held in place by the mechanical expansion of the pipes. They are equipped with threaded sleeves for the plumbing connections and the air breather valve. The coils can be rotated on site. A 2-row, direct expansion coil is also available. It is made of copper pipes with aluminium finning held in place by the mechanical expansion of the pipes.

Accessories
FAF filter G4 on intake Contained in the special housing, it is made of synthetic fibre and pleated geometry; the U-shaped frame is in galvanised sheet metal with two galvanised wire support nets SM Mixing chamber with G4 filter and dampers Galvanised steel housing complete with two air adjustment dampers with opposed fins in galvanised steel. The housing comes complete with a synthetic fibre filter (efficiency class G4, in accordance with standard EN779). SR Intake damper Consisting of a frame with galvanised steel ribbed fins. The fins are moved by nylon toothed wheels. GM Delivery grille Grille with double row of adjustable fins to introduce air into the room. GA Suction grille With tilted fins fixed at 45; can be installed directly on the device (by removing the flange) or on the wall. CMA Outer casing for grille BP One-row water-type post-heating coil applied outside the unit Contained in a special, thermally-insulated housing, it is installed on the air delivery flange only and consists of a 1-row turbo-type coil. BR Electric post-heating coil applied outside the unit The machines can be fitted with the electric coil accessory of suitable capacity. It is installed downstream of the finned coil only. PM Delivery plenum with circular start-up Sandwich panel in hot galvanised steel, with interposed polyurethane foam (40kg/m3). The panel is 15mm thick. It is installed in place of the delivery panel with rectangular flange, using the same 4 self-threading screws. Control panels: PX with selector only WMT05 Electromechanical thermostat. WMT10 control panel

FAF SM SR GM GA CMA BP

TDA09 FAF1 SM1 SR1 GM5 GA5 CMA5 BP1

Compatibility of accessories TDA15 TDA21 TDA 28 FAF2 FAF3 FAF4 SM2 SM3 SM4 SR2 SR3 SR4 GM6 GM7 GM8 GA6 GA7 GA8 CMA6 CMA7 CMA8 BP2 BP3 BP4

TDA37 FAF4 SM5 SR4 GM8 GA8 CMA8 BP5

BR PM PX WMT05 WMT10

TDA09 BR1 PM1

Compatibility of accessories TDA15 TDA21 TDA 28 BR2 BR3 BR4 PM2 PM3 PM4 (1) (1) (1) (1) (1) (1)

TDA 37 BR5 PM4 (2) (2) (2)

(1) Envision the use of SIT and the replacement of the AA fuse with one AA fuse (2) Envisions return relay, one per speed

72

Choice of Unit
By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system requirements. Code: Field configurer: TDA Size: 1 2 3 4 6 6 | | | 09, 15, 21, 28, 37 Code | Version Version: | 3 - 3-row water coil Size 4 - 4-row water coil E - 2-row direct expansion coil X - Extractor (without coil)

Technical data
Mod. TDA

Nominal air ow rate Useful static pressure (1) Cooling capacity with 3-row coil (2) Cooling capacity with 4-row coil (2) Cooling capacity with R-407C coil (3) Heating capacity with 3-row coil (4) Heating capacity with 4-row coil (4) Heating coil capacity for 4-pipe systems (4) Heating capacity with 3-row coil (5) Heating capacity with 4-row coil (5) Heating capacity with coil for 4-pipe systems (5) Electric coil capacity Electric coil power supply Fans Motors Total fan input power Fan input current Fan power supply Filter efciency (6) Sound power level (7) Connections Water battery collectors Direct expansion liquid coil pipes Direct expansion gas coil pipes Condensate discharge total sensible total sensibile totale sensibile

m3/h l/s Pa kW kW kW kW kW kW kW kW kW KW KW KW KW n kW A

9 800 222 277 4,90 3,50 6,10 4,30 5,10 3,50 10,40 12,10 5,20 5,10 6,00 2,50 4 1 1 0,357 1,6 G4 62 1 10 18 3/8

15 1400 389 330 7,40 5,60 9,70 6,90 7,50 5,20 16,60 19,90 8,80 8,10 9,80 4,30 6 2 2 0,713 3,1 G4 63 1 10 22 3/8

dB(A) mm i mm u mm

21 2000 556 227 11,10 8,20 13,10 9,40 10,70 7,40 24,20 27,30 12,60 11,90 13,40 6,00 8 230V~/50Hz 2 2 0,736 3,2 230V~/50Hz G4 70 1 12 22 1/2

28 2700 750 150 14,70 10,90 18,40 12,50 14,10 9,90 32,10 36,80 16,40 15,70 18,20 7,80 10 1 1 0,874 3,8 G4 72 1 16 28 1/2

37 3500 972 240 17,90 13,70 22,30 15,20 16,70 12,40 41,20 45,40 20,90 20,10 22,30 10,00 12 2 2 1,771 7,7 G4 73 1 16 28 1/2

(1) at nominal flow rate with 3-row coil (2) Incoming air temperature 27C d.b. 19C w.b.; water temperature (In-Out) 7C-12C (3) Incoming air temperature 27C d.b. 19C w.b.; average evap. temp. 7C

(4) (5) (6) (7)

Incoming air temperature 20C; water temperature (In-Out) 70C-60C Incoming air temperature 20C; water temperature (In-Out) 45C-40C In accordance with standard EN 779 In accordance with standard UNI EN ISO 9614

Dimensions (mm)

(*) with 4-row coil

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Telephone 0442633111 - Telefax 044293730 www.aermec.com

73

Cod.: STDAUY.01 / 0911

TDA Height (B) Width (C) Lenght (A) Net weight *

mm mm mm kg

9 300 920 630 42

15 320 1000 670 53,00

21 320 1400 670 71,00

28 380 1400 790 88,00

37 380 1400 790 91,00

TA

Air handling unit with 4 row cooling coil from 4.5 up to 32 kW 5.5 a 40 kW 6 row coil heating efficiency with 4 row coil from 14.0 up to 78.0 kW 15.5 a 87.5 kW 6 row coil

HORIZONTAL OR VERTICAL CONFIGURATION VERSION WITH 4-6 ROWS WATER COIL VERSION WITH 4 ROW EXPANSION COIL USING R410A VERSION WITH EXTRACTOR
Features
The air conditioning units in the TA range are destined to civil, commercial and hotel systems, for applications in small to medium sized environments. The units in the TA range are characterised for their compactness (indispensable requisite for typical suspended-ceiling applications), the low noise and high useful static pressure. The great availability of accessories (e.g. bag filters and the mixing chambers with 3 dampers) allows to satisfy the most varied plant requirements Structure realised with sandwich panels with thickness of 15 mm with polyurethane (density 40 kg/m3). The intake panel is equipped with a flange for fitting to any air channels. Horizontal or vertical fixing to a wall is made sleeves are supplied for the hydraulic attacheasy by the brackets. ments and the air vent valve. Filtration of the air entrusted to class G4 fil- The possibility to rotate the coils on site is ters in compliance with EN779 (thickness envisioned. 50mm) as per standard positioned at intake. Also available are coils with 4 rows with Fans double intake centrifugal with forward direct expansion operating with R410A fluid blades and directly coupled motor. and post-heating coils with 1 and 2 rows rea The 230V-50Hz single-phase motor has many lised in copper piping with aluminium louspeeds, of which three can be selected via the vers blocked via mechanical expansion of the control panel. pipes. Condensate drip tray interior isolated in aluminium alloy. Coils with 4, 6 rows that can be fed with hot or cooled water realised in coil in copper piping with aluminium louvers blocked via mechanical expansion of the pipes. Threaded

Choosing the unit


By appropriately combining the variety of options available, it is possible to configure every model in a manner that satisfies all specific implant requirements.

Fields configurator:
1 2 3 4 5 6 | | | | Code | Configuration | | | Size Version Code: TA Size: 09, 11, 15, 19, 24, 33, 40, 50 Configuration: H - Horizontal V - Vertical X - Extractor Example of a sale code: TA09H4 This is a TA unit, size 09 horizontal with 4 row coil. Version: 4 - Coil with 4 rows 6 - Coil with 6 rows E - R410A coil with direct expansion 4 left rows

74

Accessories
M2S 2 damper mixing chamber Louver pitch 50 mm; regulation pin in galva Galvanised sheet steel section complete with nised steel with diameter 8 mm mechanisatwo air calibration dampers with galvanised tion. sheet steel louvers. Louver pitch 50 mm; regulation pin in galva- VRF Recovery fan section with G4 filter nised steel with diameter 8 mm mechanisa- Fan unit, equipped with electronic varistor of tion. the number of revs. contained in a section in galvanised sheet steel equipped with flat fil M3S 3 damper mixing chamber ters with G4 efficiency (EN779). Galvanised sheet steel section complete with three air calibration dampers and galvanised PMM Plenum with multiple circular flows sheet steel louvers. Plenum equipped with sandwich panelling Louver pitch 50 mm; regulation pins in galvawith thickness of 15 mm in galvanised steel nised steel with diameter 8 mm mechanisawith polyurethane insulation. The plenum is tion. supplied with multi-diameter circular attach Va must be coupled with the VRF accessory ments (200 mm, 180 mm and 150 mm) in plastic to allow the connection of circular FTF Soft bag filters section conduits. Galvanised sheet steel section complete with soft bag filters with F6 filtration level. PMC Closed flow plenum For different filtrations, contact the AERMEC Plenum closed equipped with sandwich technical-sales dept. panelling with thickness of 15 mm in galvanised steel with polyurethane insulation. B1R 1 row water coil The plenum allows to turn the flow by 90. For 4 pipe systems, positioned internally, The opening of the flow hole is the installer's downstream from the main coil. responsibility. Threaded sleeves are supplied for the hydraulic attachments and the air vent valve. SAS Intake damper Air calibration damper with galvanised sheet B2R 2 row water coil steel louvers. For 4 pipe systems, positioned internally, Louver pitch 50 mm; regulation pin in galvadownstream from the main coil. nised steel with diameter 8 mm mechanisa Threaded sleeves are supplied for the hydraution. lic attachments and the air vent valve. GMD Flow grid with moveable louvers PBE Section with post-heating coil Grid with double order of moveable louvers The electric coil is made up from armoured for the introduction of air into the room to be resistances equipped with double safety therconditioned. mostat. It can be installed directly onto the appliance by removing the flanges or on the wall. SSL Module with seven silencers Galvanised sheet steel section complete with GAP Intake grid seven silencers in mineral wool covered with With fixed louvers inclined by 45; can be a polyethylene film to prevent exfoliation. installed directly onto the appliance by removing the flanges or on the wall. S2Z Damper with 2 areas (70-30%) Galvanised sheet steel damper with opposite FPI G4 flange filters louvers for the mixture of the external air flow PX Switch-over only control panel and the flow of recirculation air. Accessories compatibility TA 15 TA 19 TA 24 M2S2 M2S3 M2S4 M3S2 M3S3 M3S4 FTF2 FTF3 FTF4 B1R2 B1R3 B1R4 B2R2 B2R3 B2R4 PBE3 PBE4 PBE5 SSL2 SSL3 SSL4 S2Z2 S2Z3 S2Z4 VRF3 VRF4 VRF5 PMM2 PMM3 PMM4 PMC2 PMC3 PMC4 SAS2 SAS3 SAS4 GMD2 GMD3 GMD4 GAP2 GAP3 GAP4 FPI2 FPI3 FPI4 (1) (1) (1) (1) (1) (1) WMT 05 Electro-mechanical thermostat For fan coils installed in 2 pipe systems The panel must be installed on the wall and protected electrically by an internal fuse. Has the following functions: on/off switch; cursor for the selection of heating/cooling modes (manual season change); cursor for the selection of fan speed (high, medium and low); temperature selector switch (+5C30C) WMT10 Control panel For can coils with wall installation. Control functioning of the fan coil depending on the mode set. The panel must be mounted on the wall, it is used on 4 pipe and 2 pipe and 2 pipe with resistance systems, with the possibility of connecting two On - Off type valves for the cut-off of the coil supply water. The panel is protected electrically by an internal fuse. The control has the following functions: cursor for the selection of the cooling or heating functioning mode; manual season change; manual selection of the fan speed selection of the desired environment temperature (+10CA30CA); 2 pipe systems management; 4 pipe systems management; 2 pipe systems management (cooling) + electrical resistance (heating); thermostat ventilation; continuous ventilation; continuous ventilation in cooling mode and thermostat ventilation in heating mode.

M2S M3S FTF B1R B2R PBE SSL S2Z VRF PMM PMC SAS GMD GAP FPI PX WMT 05 WMT 10

TA 09 M2S1 M3S1 FTF1 B1R1 B2R1 PBE1 SSL1 S2Z1 VRF1 PMM1 PMC1 SAS1 GMD1 GAP1 FPI1

TA 11 M2S1 M3S1 FTF1 B1R1 B2R1 PBE2 SSL1 S2Z1 VRF2 PMM1 PMC1 SAS1 GMD1 GAP1 FPI1 (1) (1)

TA 33 M2S4 M3S4 FTF4 B1R4 B2R4 PBE6 SSL4 S2Z4 VRF6 PMM4 PMC4 SAS4 GMD4 GAP4 FPI4 (2) (2) (2)

TA 40 M2S5 M3S5 FTF5 B1R5 B2R5 PBE7 SSL5 S2Z5 VRF7 PMM5 PMC5 SAS5 GMD5 GAP5 FPI5 (2) (2) (2)

TA 50 M2S5 M3S5 FTF5 B1R5 B2R5 PBE8 SSL5 S2Z5 VRF8 PMM5 PMC5 SAS5 GMD5 GAP5 FPI5 (2) (2) (2)

(1) Envision the use of SIT and the replacement of the 2A fuse with one 4A fuse (2) Envisions return relay, one per speed

75

Technical data
Mod. TA Nominal air ow rate Useful static pressure (1) Cooling capacity with 4 row coil (2) Cooling capacity with 6 row coil (2) Cooling capacity with 4 row coil with direct exp.R-410A (3) Heating capacity with 4 row coil (4) Heating capacity with 6 row coil (4) 1 row water coil heating capacity for 4 row pipes (8) 2 row water coil heating capacity for 4 row pipes (8) Heating capacity with 4 row coil (5) Heating capacity with 6 row coili (5) 1 row water coil heating capacity for 4 row pipes (5) 2 row water coil heating capacity for 4 row pipes (5) Electric coil capacity Number of electric coil stages Electric coil power supply Fans Motors Fans total input power Fans input current Fans power supply Poles Flat lters capacity (6) Soft bag lters efciency (6) Sound power level (7) Connections Coils collectors Direct expansion coil pipes Condensate Drain IN OUT total sensible total sensible total sensible m3/h l/s Pa kW kW kW kW kW kW kW kW kW KW KW KW KW KW KW n n n W A n 9 900 250 110 4.7 3.5 5.4 3.9 6.6 4.2 14.2 15.7 5.2 8.4 5.5 6.1 2.2 3.6 4 2 1 1 357 1,6 2 G4 F6 63 1" 16 22 11 1100 306 277 5.7 4.2 6.7 4.7 7.3 4.7 16.6 18.5 5.7 9.5 6.4 7.2 2.4 4.1 6 2 2 2 713 3,1 2 G4 F6 66 1" 16 22 15 1500 417 249 8.7 6.2 11.7 7.5 11.0 7.0 23.9 26.6 9.2 14.2 9.3 10.5 4.0 6.2 8 2 2 2 713 3,1 2 G4 F6 67 1" 16 22 19 24 1900 2400 528 667 223 165 12.4 17.3 8.3 11.2 15.5 20.6 9.8 12.8 14.2 19.2 9.1 12.1 30.8 40.6 34.2 44.3 11.4 15.9 17.9 24.3 12.1 16.0 13.6 17.6 4.9 6.9 7.8 10.6 10 12 2 2 400V-3-50Hz 1 1 1 1 886 874 3,9 3,8 230V-1-50Hz 4 4 G4 G4 F6 F6 72 74 1" 16 22 1" 16 22 33 3300 917 215 21.7 14.3 26.3 16.6 23.0 14.8 52.2 58.0 18.3 29.9 20.6 23.0 7.9 13.0 16 2 2 2 1771 7,7 4 G4 F6 75 1" 16 22 40 4000 1111 220 27.2 18.0 33.5 20.9 30.5 19.4 65.8 72.6 25.2 38.9 25.9 28.9 10.9 16.9 20 2 2 2 1771 7,7 4 G4 F6 76 1" 22 28 50 5000 1389 163 31.8 21.3 39.6 25.0 34.5 22.3 78.3 87.5 27.7 44.9 30.8 34.8 12.0 19.5 24 2 2 2 2852 12,4 4 G4 F6 79 1" 22 28

dB(A) inc. mm. mm. inc.

(1) (2) (3) (4) (5) (6) (7) (8)

At nominal capacity with 4 row coil Entry air temperature 27C d.b. 19C w.b.; water temperature (Ent-Ex) 7C - 12C Entry air temperature 27C d.b. 19C w.b.; medium evap. temperature 2C Entry air temperature 10C; Water temperature (Ent-Ex) 70C - 60C Entry air temperature 20C; Water temperature (Ent-Ex) 45C - 40C Inc with the EN 779 Standard Sound power in compliance with UNIX EN ISO 9614-2 Standards Entry air temperature 15C; Water temperature (Sent-Ex) 70C - 60C

76

Dimensional data (mm)

A D

TA HORIZONTAL INSTALLATION AND WITH EXTRACTOR

Mod. TA 9 11 HORIZONTAL CONFIGURATION DIMENSIONS AND "EXTRACTOR" CONFIGURATION Height (B) mm 300 300 Width (C) mm 700 700 Lenght (A) mm 700 700 Connections projection (D) mm 82 82 Number of fans n 1 2

15 300 1050 700 82 2

19 390 1050 850 82 1

24 390 1475 850 82 1

33 390 1475 850 82 2

40 390 2100 1000 82 2

50 390 2100 1000 82 2

F
36,5

F A

TA VERTICAL INSTALLATION Mod. TA VERTICAL CONFIGURATION DIMENSIONS Height (B) Width (C) Lenght (A) Fixing points (D) (E) (F) Number of fans UNIT NET WEIGHTS 4 row coil 6 row coil Extractor
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

9 mm mm mm mm mm mm mm n 840 300 700 732 655 70 1 9 28 30

11 840 300 700 732 655 70 2 11 33 35

15 840 300 1050 1082 655 70 2 15 45 47

19 1090 390 1050 1082 905 70 1 19 60 62

24 1090 390 1475 1507 905 70 1 24 78 81

33 1090 390 1475 1507 905 70 2 33 86 89

40 1090 390 2099 2131 905 70 2 40 135 139

50 1090 390 2099 2131 905 70 2 50 140 144

mm kg kg

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

77

Cod.: STAUY.00 / 0910

NEW

TN

Air conditioning unit Air flow from 2300 to 23000 m3/h.

The TN units are destined to commercial and industrial plants for medium size rooms. The series consists of eight sizes with nominal air ow from 3000 m3/h to 23000 m3/h and allows the ltration, heating and / or cooling treatments. The performances are ensured by high efciency heat exchangers and high pressure fans coupled to the motor by variable pulley and belt. The compactness, low noise level, and the wide range of accessories gives the TN series a huge versatility in order to adapt to customer requirements: in addition to the possibility of transforming the model from horizontal to vertical and the contrary too, it has been chosen to add a enhanced conguration to ensure a higher pressure of the fan.

Features
VERSIONS: 8 available sizes in vertical configuration with the possibility to change them in horizontal version. Enhanced configuration to ensure a higher pressure of the fan. FANS: Fans are centrifugal type, double suction and FILTERS forward blades with high performances. These filters are easily removable to facilitate their maintenance and cleaning; they are pla MOTORS: ced on guides of the main coils section. The installed electrical motors are asynchro- The removal of filters can be done pulling nous three-phase, with closed frame and outthem sideways through the door on the panel, side ventilation, comply with the regulations connections side. IEC, CEI, UNEL (protection class IP55), single With the accessory FTMxT, the filtration is speed (4 poles). made through compact filters with a F7 filtration degree. TRANSMISSIONS: Pulleys are with variable diameter to better set of the fan to the installation. Belts can be SPA or SPB type. They are supplied with conical clamping , Taperlock type and are statically and dynamically balanced.

FRAME: The frame is made of aluminum profiles with sandwich panels made of galvanized steel inside and prepainted galvanized steel RAL 9002 outside with polyurethane insulation (density 40 kg / m) and thickness of 25 mm. Both panels of the base unit and panels of the plenum are provided with pre-cuts which allow to make them compatible with the integration of accessories. The fastening of the panels through profile block panel, ensures a perfect seal between panel and frame, and an extreme ease of WATER HEAT EXCHANGERS: assembly/ disassembly of the panels. The 3 ways corner joint is made of nylon The water heat exchangers are made of copper pipes and aluminum fins, blocked by reinforced with glass fibers. mechanical expansion of the tubes; the main The condensate drain pan, in galvanized coil can be 4 or 6 rows (hot or cold) and 2, 3 steel, is provided with threaded drain conor 4 rows the secondary one (only hot ). nection on both sides and it is suitable for both horizontal and vertical installation of the The filtration is carried out by 50 mm thick synthetic filters with G4 efficiency class unit. (according to EN 779) placed on suction side.

78

Accessories
PLxT supply and suction plenum: compatible with GAxT, GMxT and TPPLxT. FT7MxT compact lters F7 on fans supply: compatible with GMxT, SAxT and TPPxT. B2RxT - B3RxT - B4RxT batteria a acqua calda a 2 - 3 - 4 ranghi per impianti a 4 tubi. SAxT suction damper: to be installed on the base unit or on plenums. GMxT supply grille with adjustable ns: to be installed on the base unit or on plenums. GAxT suction grille with xed ns, 45 bended: to be installed on the base unit or on plenums. TPVSxT protection roof for vertical installation with up supply: to be installed on the base unit. TPVFxT protection roof for vertical installation: to be installed on PLxT, FT7MxT and vertical base unit with front supply. TPLxT protection roof for horizontal version with front supply: to be installed on the base unit. TPPLxT plenums protection roof for horizontal installation with front supply: to be installed on PLxT e FT7MxT from size 3 to 8. TPFTLxT bag lter protection roof for line installation with front supply. P50MBT corners support feets for horizontal and vertical versions. P50ACT side support feets for horizontal version.

GAxT GMxT SAxT B2RxT B3RxT B4RxT PLxT FT7MxT TPVSxT TPVFxT TPLxT TPPLxT TPFTLxT P50MBT P50ACT

Montage V-O V-O V-O V-O V-O V-O V-O V-O V V O O O V-O O

TN1 GA1T GM1T SA1T B2R1T B3R1T B4R1T PL1T FT7M1T TPVS1T TPVF1T TPL1T TPPL1T TPFTL1T

TN2 GA2T GM2T SA2T B2R2T B3R2T B4R2T PL2T FT7M2T TPVS2T TPVF2T TPL2T TPPL2T TPFTL2T

TN3 GA3T GM3T SA3T B2R3T B3R3T B4R3T PL3T FT7M3T TPVS3T TPVF3T TPL3T TPPL3T TPPL3T

TN4 GA4T GM4T SA4T B2R4T B3R4T B4R4T PL4T FT7M4T TPVS4T TPVF4T TPL4T TPPL4T TPPL4T

TN5 GA5T GM5T SA5T B2R5T B3R5T B4R5T PL5T FT7M5T TPVS5T TPVF5T TPL5T TPPL5T TPPL5T

TN6 GA6T GM6T SA6T B2R6T B3R6T B4R6T PL6T FT7M6T TPVS6T TPVF6T TPL6T TPPL6T TPPL6T

TN7 GA7T GM7T SA7T B2R7T B3R7T B4R7T PL7T FT7M7T TPVS7T TPVF7T TPL7T TPPL7T TPPL7T

TN8 GA8T GM8T SA8T B2R8T B3R8T B4R8T PL8T FT7M8T TPVS8T TPVF8T TPL8T TPPL8T TPPL8T

P50MBT P50ACT

V - O = This accessory can be mounted both on the vertical version and horizontal version; V = This accessory can be mounted only on the vertical version; O = This accessory can be mounted only on the horizontal version;

79

Technical data
TN1 3000 3500 3500 215 390 15,6 10,7 20 13,4 18,9 12 23,9 15 25,2 33,5 40 48,7 14,7 19,6 23,4 28,5 1" 1" 1" 1" 280 V/n/Hz kW/n 0,75 / 4 kW/n 1,1 / 4 9 9 10 G4 F7 52 TN2 4100 4700 4700 235 407 21,3 14,7 27,4 18,3 25,8 16,4 32,9 20,5 34 45,6 54,5 66,6 19,8 26,6 31,9 38,9 1" 1" 1" 1" 280 TN3 5650 6400 6400 236 458 29,1 20,1 37,7 25,2 35,3 22,4 45,3 28,3 46,8 62,7 74,9 91,5 27,3 36,6 43,7 53,5 1" 1" 1" 1/2 1" 1/2 315 TN4 7350 8000 8400 226 454 38,1 26,2 49,2 32,8 46,3 29,3 59,2 36,9 61,5 82 97,6 119,2 36 47,9 57 69,6 1" 1" 1" 1/2 1" 1/2 315 TN5 9300 10000 10900 156 340 44,8 33,3 58,3 41,1 56,1 37,5 71,6 46,4 84,4 110,8 131,1 157,5 49 64,4 76,3 91,7 1" 1" 1/2 1" 1/2 1" 1/2 400 TN6 11700 13400 13400 193 438 56,7 41,7 74,5 51,8 70,7 46,9 90,6 58,3 103,8 137,3 162,9 196,8 60,3 79,8 94,8 114,3 1" 1/2 1" 1/2 1" 1/2 1" 1/2 400 TN7 15500 17800 17800 207 396 74,7 55,1 98,9 68,8 93,3 62,1 120,3 77,4 138 182,5 216,1 260,4 80,1 106,1 125,8 151,7 1" 1/2 1" 1/2 1" 1/2 2" 500 TN8 20000 20000 23000 131 381 96,4 70,9 127,8 88,5 120,2 79,8 155,1 99,6 178,5 234,4 277,3 334,1 103,8 136,3 161,4 194,6 1" 1/2 1" 1/2 2" 2" 500

Max. airflow Max. airflow Max. airflow Fans available pressure Maximum fans Cooling power with coils 4 rows Cooling power with coils 6 rows Cooling power with coils 4 rows Cooling power with coils 6 rows Heating power with coils 2 rows Heating power with coils 3 rows Heating power with coils 4 rows Heating power with coils 6 rows Heating power with coils 2 rows Heating power with coils 3 rows Heating power with coils 4 rows Heating power with coils 6 rows COILS Manifolds diameter 2 rows Manifolds diameter 3 rows Manifolds diameter 4 rows Manifolds diameter 6 rows Condensate discarge diameter FAN MOTOR Power supply Power/Poles (base unit) Power/Poles (enhanced unit) FILTERS Plane filters efficiency Compact filters efficiency (accessory) Mouth sound pressure

1 2 3 4 4 5 5 6 6 7 7 7 7 8 8 8 8 Base unit Enhanced unit Total Sensible Total Sensible Total Sensible Total Sensible

m3/h m3/h m3/h Pa Pa kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW

1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F 1"M- 3/4"F

1,1 / 4 1,5 / 4 G4 F7 54

1,5 / 4 2,2 / 4 G4 F7 55

400V/3/50Hz 2,2 / 4 2,2 / 4 3/4 3/4 G4 F7 57 G4 F7 56

4/4 5,5 / 4 G4 F7 58

4/4 5,5 / 4 G4 F7 59

5,5 / 4 7,5 / 4 G4 F7 64

note (1): with cooling coil ; note (2): with heating coil, base unit; note (3): with heating coil, enhanced unit; nota (4): alla portata aria massima 1 with cooling coil 4 rows and lters G4 fouling medium life note (5): Air temperature enters 27 C d.b. 19 C w.b.; water temperature (In-Out) 7 C - 12C.; nota (6): Air temperature enters 27 C d.b 19 C w.b.; water temperature (In-Out) 5 C - 10C.; nota (7): Air temperature enters 10 C; water temperature (In-Out) 70 C - 60C.; nota (8): Air temperature enters 10 C; water temperature (In-Out) 45 C - 40C.; nota (9): comply with the regulation EN 779; nota (10): d = 10 m, Q =2, base version, at min. pressure, nominal air ow with cooling coil.

80

Dimensions (mm)

TN models Height Width Lenght Weight (base version coil 6R) Weight (enhanced version coil 6R)

A B C

mm mm mm kg kg

TN1 1334 684 928 190 200

TN2 1334 684 1172 220 223

TN3 1497 765 1334 275 283

TN4 1497 765 1659 320 321

TN5 1822 828 1659 415 417

TN6 1822 828 1984 475 502

TN7 2309 1172 1984 630 657

TN8 2309 1172 2472 807 813

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

81

Cod.: STNUY.00 / 1301

Objective air quality and energy saving: Aermec offers a large range of air-air heat recovery units for industrial and commercial systems and for Controlled Mechanical Ventilation Systems for residential. The heat recovery units, provided with appropriate accessories (heat exchange coils, heat pump refrigerant circuit, etc.), actively participate in the air treatment providing an important contribution to the air conditioning of the spaces served. The catalogued range of nominal available air flow rates is from 100 to around 16.100 m/h.

02. HEAT RECOVERY UNIT

NEW

RePuro

Heat recovery unit

high efficiency

Plasmacluster

RePuro is an innovative counter-ow heat recovery system which ensures the correct renewal of air to indoor environments. Through the use of up to 90% high efciency heat exchangers RePuro allows the introduction of fresh air at a temperature close to that of the room concerned, reducing energy costs that would be incurred in exchanging the air in traditional ways or by mechanical ventilation alone. PLASMACLUSTER ionising lter. Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them. The result is in the air: you can nally breath clean, odour-free ionised air. Characteristics
Available in 7 sizes 2 versions: - standard, with frost protection for climates >-10C (RePuro 250-350-450-550-650) - R, (RePuro 250R-350R-450R-550R-650R) with electric pre-heater for continuous operation in cold climates <-10C Wall installation and ceiling (RePuro 100-170) High efficiency of 90% and above (UNI EN 308) Free-cooling in mid-seasons through the automatic by-pass function (RePuro 250350-450-550-650) By-pass no frost (RePuro 450-550-650) Flow rate control 0-100% of nominal air flow rate Ionizer filter PLASMACLUSTER as standard Regulation flow rate 0-100% of nominal flow rate Direct drive centrifugal fans, with "Brushless" EC high efficiency variable speed electric motors (ERP2015) Microprocessor controller with interface capability to the VMF system Monitoring of the units with remote wired control panel (supplied as standard). Innovative design, extremely slim, allows control of functions via a touch keypad with LCD display. The panel cable is 6 metres long supplied as standard. Activation of the electric heater in the RePuro_R version. Front in light grey colour PANTONE COOL GRAY 1C Heat exchanger with hexagonal shape to increase the surface area Heat exchanger easily removed from the front for cleaning or replacement Casing in galvanised sheet steel with internal insulation Easy to wall mount with standard supplied mounting plate, or oor mount with antivibration mounts AVM accessory Simple to configure Adaptable to existing systems Compact size Quiet operation Standard filter on fresh air G4 Standard filter on extract air G2 Filters can be removed for cleaning or replacement The installation requires a condensate drain system. trols Modu_Control, GR3 and pCO 2 / pCO3 (required accessory RS 485 interface

Accessories
AVM : Anti-vibration mounts SSR : Bearing bracket (RePuro 250-350450-550-650) FF7 : Air filters for fresh air with F7 efficiency KSAE : External air temperature sensor PLS : Plenum with acoustic lining equipped with multi-way flange to ensure a uniform distribution in all treated areas. The plenum is configured with: - electric heater - germicidal lamp - water coil. PLSM : Plenum with acoustic lining equipped with one-way flange. The plenum is configured with: - electric heater - germicidal lamp - water coil. VCH : Kit consisting of powered 2-way valve, copper couplings and pipes. combined with the accessory PLS in the conguration with the water heat exchanger. In cooling recovery i requires an accessory tray BC. BC :Auxiliary condensate drip tray. BC10 for vertical installation. BC20 for horizontal inswtallation. VMF-E5B : White recessed panel, with backlit graphic LCD and touch keypad allowing the centralised command/control of a complete hydronic system consisting of: - Heat recovery units: up to 3 outputs for heat recovery units programmed according to time-clocks and/or by measuring the air quality obtained with the VMF-VOC accessory; - Fan coil units: up to 64 fan coil zones comprising 1 master + maximum 5 slaves; - Chiller/heat pump unit equipped with con-

84

respectively MODU-485A, AER485, AER485P2 / AER485P1), - Circulators: maximum of 12 configurable zone circulators; - Boiler: boiler enable for hot water production; - Domestic hot water module: complete management of the production of domestic hot water through the control of diverting valve/circulator, immersion heater, storage tank temperature sensor, anti-legionella cycle. VMF-E5N : Variant of the VMF-E5B panel but with black coloured plastic. VMF-VOC : Accessory for measuring air quality (see relevant point in the description of the VMF-E5B panel). VMF-CRP : ccessory module for the control of the boilers, pumps and heat recovery units.

Technical data
100
Nominal air ow rate Available static pressure Winter recovery efciency Recovered heating capacity Winter recovery efciency(*) Recovered heating capacity (*) Summer recovery efciency Recovered cooling capacity Air ow rate (2) Available static pressure Winter recovery efciency Recovered heating capacity Winter recovery efciency(*) Recovered heating capacity (*) Summer recovery efciency Recovered cooling capacity Air ow rate (1) Available static pressure Winter recovery efciency Recovered heating capacity Winter recovery efciency(*) Recovered heating capacity (*) Efcienza recupero estivo Potenza termica recuperata Weight Maximum power input Power supply Winter recovery conditions 20C db 50% RH -10C db Fresh air 80% RH The available static pressure can differ from nominal value due to the antifreeze control Extract air m3/h Pa % W % W % W m3/h Pa % W % W % W m3/h Pa % W % W % W Kg W V ~ Hz 100 85 94,4 957 90,6 601 90,6 180 75 135 95,7 728 92,7 462 92,7 138 50 185 97 492 95 315 95 95 25 45

170
170 20 91,2 1573 85,3 963 85,3 289 125 110 93,2 1181 88,6 735 88,6 220 75 210 95,7 728 92,7 462 92,7 138 25 65

250
250 195 91,9 2329 86,3 1433 86,4 430 150 331 94,8 1441 91,1 908 91,2 272 75 426 97,2 739 95,3 475 95,3 142 48 160 EN 308 25C db 27% RH 5C db 50% RH

350
350 133 89,4 3171 82,2 1910 82,2 573 200 376 93,3 1891 88,6 1177 88,7 353 100 526 96,4 977 93,9 623 93,9 187 48 180 230 ~ 50

450
450 100 90,3 4118 83,7 2500 83,7 750 300 210 93 2830 88,2 1758 88,3 527 150 310 96,2 1463 93,6 932 93,6 280 55 220 Summer recovery conditions Extract air Fresh air

550
550 120 88,6 4940 81 2957 81 887 350 300 92,1 3267 86,6 2014 86,7 604 175 430 95,7 1697 92,7 1077 92,7 323 55 280

650
650 70 87 5734 78,4 3386 78,5 1015 450 270 90,3 4118 83,7 2500 83,7 750 200 485 95,1 1928 91,7 1218 91,7 365 55 360

* Winter recovery conditions Extract air Fresh air

26C db 50% RH 32C db 50% RH

(1) (2) The performances provided conditions are different from the nominal

Dimensions (mm)
Extract air Fresh air

77 150

6m

180
150

150

427

33

160
800
242

750
575

655

520

72*

800

72*

530

RePuro 100 - RePuro 170


Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

RePuro 250 - RePuro 350 * = with AVM accessory


Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

RePuro 450 - RePuro 550 - RePuro 650

85

Cod.: SREPUY.03 / 1301

NEW

TRS

Heat recovery unit with enthalpic heat exchanger

TRSCPR

TRSCP

These units allow the extraction of a fixed amount of air from the room to be replaced with fresh air. Static type heat recovery unit with high efficiency in counter-flow, consisting of flat sheets of special paper. This particular material allows a "total" type heat exchange as both sensible heat and the latent heat (moisture) are recovered with average efficiency of 75% on the temperature (depending on the models) and 60% on the enthalpy, with high performance even in summer. The air flows are kept separated by a suitable sealing.

Features
Available in 6 sizes for horizontal installation High efficiency superior to that obtained from the units with only the recovery of sensible heat Free-cooling during spring and autumn thanks to automatic by-pass function Double suction centrifugal fans, directly coupled to high-efficiency "Brushless DC" electric motors, equipped with adjustable speed using an electronic regulator to vary the flow rate Control of the units between the control panel with LCD display (TRSCP accessory) or Kit with wired control panel with LCD display and remote control (TRSCPR accessory) Enthalpic heat recovery unit with hexagonal shape to increase the exchange surface Enthalpic heat recovery unit can be easily removed laterally for cleaning or replacement Self-supporting galvanized steel metal panels with insulation. Compact size for installation in suspended ceilings Inlet air filter, both on the external air inlet side and on the fresh air from the room side Synthetic filter on the internal air inlet with class G4 Filters laterally removable for cleaning or replacement Quiet operation The installation does not require the condensate discharge system

Accessories
It is mandatory to use one of the two accessories as they are essential to the operation of the units: TRSCP: Wired control panel with LCD display TRSCPR: Remote control and wired control for controlling the On-Off functions, speed panel with LCD display for control of the selection, weekly programmable timer, On-Off functions, speed selection, weekly automatic Free-Cooling function. IR receiver programmable timer, automatic Free-Cooling for operation coupled to the IR remote function. IR receiver for operation coupled to control accessory. the IR remote control accessory. Recessed wall mounting in "module 502" Recessed wall mounting in "module 502" electrical boxes. electrical boxes. Compatibility of accessories

TRS15
TRSCP TRSCPR

TRS25

TRS35

TRS50

TRS80

TRS100

86

Technical data
HEAT RECOVERY UNIT Winter operation Efciency Summer operation Efciency Temperature Enthalpy Power recovered at full speed Maximum Average Minimum Maximum Average Minimum Maximum Average Minimum Maximum Average Minimum % % kW m3/h m3/h m3/h Pa Pa Pa W W W dB(A) dB(A) dB(A) V/ph/Hz 63 60 0.5 150 150 100 85 70 50 80 55 30 26 24 22 62 60 0.8 250 250 160 85 65 30 90 60 35 27 26 22 63 61 1.2 350 350 270 90 60 30 120 80 45 31 29 25 230/1/50 62.5 60 1.7 500 500 360 100 60 30 135 110 60 33 31 27 59 57 2.5 800 800 625 150 100 40 300 190 110 38 36 32 59.5 57.5 3.2 1000 780 650 150 100 40 310 200 125 39 37 33 Temperature Enthalpy Power recovered at full speed % % kW TRS15 77 62 1.3 TRS25 76 62 2.2 TRS35 77 63 3.1 TRS50 76.5 62.3 4.3 TRS80 73 59 6.5 TRS100 73.5 59.5 8.2

Nominal air ow rate

Useful static pressure (*)

Input power

Sound pressure level Power supply

Performance values refer to the following conditions: (*) Values referring to the nominal ow net of heat recovery unit and lter pressure drops Sound pressure level (A-weighted) measured in free eld at a distance of 1.5 metres from the inlet of the unit. The operation noise level generally differs from the values shown, depending on operating conditions, reected noise and surrounding noise. Nominal conditions in winter operation: - external air: -5C W.B.; R.H. 80% - room air: 20C W.B.; R.H. 50% Nominal conditions in summer operation: - external air: 32C W.B.; R.H. 50% - room air: 26C W.B.; R.H. 50%

Dimensions (mm)
Inspection panel
E d D A2 A A1 C

Wired panel

B1

B2

Outlet air Fresh air Remote control

A TRS15 TRS25 TRS35 TRS50 TRS80 TRS100 885 885 885 970 1322 1322

A1 815 815 815 910 1252 1252

A2 1074 1074 1074 1130 1486 1486

B 666 666 806 997 882 1132

B1 720 720 860 1053 936 1186

B2 779 779 919 1112 994 1244

C 272 272 272 312 390 390

D 342 342 482 728 431 681

E 110 110 110 38 169 169

d 100 150 150 200 250 250

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

87

Code: STRSUY.00 / 1203

Weight (kg) 27 27 32 42 63 76

UR

Heat recovery unit

These units allow to extract a certain amount of exhaust air from the room and supply an equivalent quantity of fresh air. A crossflow aluminium plate exchanger assures an efficient heat exchange between exhaust and fresh air: therefore the fresh air is pre-heated or precooled according to the seasons. The supply air is filtered before entering the heat recovery exchanger that is protected with a synthetic filter also at the exhaust air side. The supply air can optionally be re-heated with a hot water coil or with an electric coil.

Features
7 sizes are available: UR: standard version UR W: same as standard version and equipped with water heating coil with copper tubes and 3 rows aluminium fins. Not to be used with chilled water UR E: same as standard versions and equipped with electric heating coil with aluminium fins and double safety thermostat Double suction centrifugal fans coupled directly to the electric motors, equipped with adjustable speeds via an electronic control to vary the flow rate cleaning or replacement G3 class synthetic filter on the air outlet Two versions available for horizontal and ver Aluminium plate reheater housed in the contical installation (it is not possible to install densate tray that is easily removed from the the cooling coil accessories and silencers for bottom the vertical installation) G3 class synthetic filter on the fresh air intake Electronic Regulator with Slave Application Self-bearing panels made of galvanized plate allowing continuous variation of rotation with injected polyurethane insulation and speed and air flow rate thickness 20 mm. Galvanized condensate tray Fans can be inspected from the bottom Filters can be removed from the bottom for

88

Accessories
BF: Water cooling coil. coil and 1-row water post-heating coil. FGC: Circular flanges. MPX : Module with 4-row water cooling G4: High-efficiency filters on the fresh air coil and electric post-heating coil with reinintake in class G4. forced finned coils. Safety thermostat inclu MPW: Module with 4-row water cooling ded. Compatibility of accessories Horizontal installation: BF 35 BF 55 BF 75 BF 100 BF 150 BF 210 BF 330 FGC 1 FGC 2 G4 35 G4 55 G4 75 G4 100 G4 150 G4 210 G4 330 MPW 35 MPW 55 MPW 75 MPW 100 MPW 150 MPW 210 MPW 330 MPX 35 MPX 55 MPX 75 MPX 100 MPX 150 MPX 210 MPX 330 SE 1 SE 2 SE 3 SE 4 SE 5 SU 1 SU 2 SU 3 SU 4 SU 5 Vertical installation: FGC 1 FGC 2 G4 35 G4 55 G4 75 G4 100 G4 150 G4 210 G4 330 SE 1 SE 2 SE 3 SE 4 SE 5 UR 35 UR 55 UR 75 UR 100 UR 150 UR 210 UR 330 UR 35 UR 55 UR 75 UR 100 UR 150 UR 210 UR 330 SE: Free-Cooling control dampers. SU: Silencers. Compatibility with the VMF system For further system information please refer to the specific documentation.

89

Technical data
Mod. Air ow Recoverer: Efciency Heat capacity recovered Cooling capacity recovered Output temperature Fan motor assembly: Fans Total input power Max. input current Fan speed variation Available static pressure (Pa) Electrical protection Insulation class Filtres: EN779 Classication Efciency Water heating coil (UR W): Geometry Rows Fin pitch Frontal surface area Heating capacity (1) Air output temperature (1) Heating capacity (2) Air output temperature (2) Heating capacity (3) Air output temperature (3) Electric heating coil (UR E): Heating capacity Air side pressure drop Stages Input current Air output temperature (air 8 C) m3/h UR 35 350 UR 55 550 UR 75 750 UR 100 1000 UR 150 1500 UR 210 2100 UR 330 3300

% kW kW C

52,1 1,5 0,4 8

55 2,5 0,7 8,7

54,3 3,4 1 8,6

54,4 4,6 1,3 8,6

53,1 6,7 1,9 8,3

52,7 9,3 2,6 8,2

52 14,3 4,3 8

n. kW A

2 0,27 1,1 continous UR Standard 125 UR E 115 UR W 50 IP 44 B

2 0,44 1,7 continous 140 130 50 54 F

2 0,65 2,8 continous 170 160 50 44 F

2 1,12 5 continous 150 140 70 55 F

2 1,12 5 continous 120 110 50 55 F

2 2 8,6 continous 120 110 50 55 F

4 4 17,2 continous 150 140 50 55 F

G3 80

G3 80

G3 80

G3 80

G3 80

G3 80

G3 80

n. mm m2 kW C kW C kW C

P2519 3 1,8 0,027 4,9 48 4,1 41,2 2,4 27,7

P2519 3 1,8 0,047 8,1 50 6,7 43 4 28,7

P2519 3 1,8 0,052 10,6 48 8,8 41,3 5,2 27,8

P2519 3 1,8 0,092 15,5 52 13 45 7,7 30

P2519 3 1,8 0,119 22,4 51 18,7 43,6 11,2 29,2

P2519 3 1,8 0,165 31 50 25,9 43 15,4 29

P2519 3 2,1 0,237 43 46 36,6 39,5 22 27

kW Pa n. A C

2.5 10 2 4,6 34

2.5 10 2 4,6 25

5 10 2 9,1 32

5 10 2 9,1 26

10 10 3 15,2 28

15 10 3 22,7 29

25 10 3 37,9 31

Water cooling coil accessory with box to be positioned after the discharge fan: Frontal surface area m2 0,075 0,075 Rows n. 4 4 Cooling capacity (4) kW 2 3 Air side pressure drop Pa 25 57 Power supply = 1~ 230V 50Hz (3N~ 400V 50 Hz per le resistenze elettriche). Performance values refer to the following conditions: - room air temperature 20 C; - ambient air temperature -5 C.

0,1125 4 4 48

0,2125 4 6,9 25

0,2125 4 8,8 54

0,25 4 12 74

0,25 4 17,5 105

(1) air temp. 8 C - water temp. 80/70 C (2) tair temp. 8 C - water temp. 70/60 C (3) air temp. 8 C - water temp. 45/40 C (4) air temp. 27 C - HR 50% - water temp. 12/7 C

90

Lay-out (horizontal configuration)


Exaust air Espulsione aria viziata Supply air Mandata in ambiente Supply air in Mandata ambiente Exaust air Espulsione aria viziata

Fresh air inlet Aspirazione aria di rinnovo

Return air Ripresa dall'ambiente

Return air Ripresa dall'ambiente

Fresh air inlet Aspirazione aria di rinnovo

Supply air Mandata in ambiente

Return air Ripresa dall'ambiente

Exaust air Espulsione aria viziata

Fresh air inlet Aspirazione aria di rinnovo

Exaust air Espulsione aria viziata

Fresh air inlet Aspirazione aria di rinnovo

Supply air Mandata in ambiente

Return Ripresaair dall'ambiente

Warning : the above diagrams refer to the unit in horizontal configuration only. For the vertical configuration, please consult the manual.

Dimensions (mm)

Mod. UR Height Width Depth Weight (kg)

A B C UR Std UR E UR W

35 1090 900 300 61 62 62

55 1090 900 300 65 66 66

75 1190 1000 330 74 75 75

100 1500 1250 390 115 117 117

150 1500 1250 390 130 133 133

210 1750 1400 390 170 174 174

330 2500 1750 390 280 286 286

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

91

Cod.: SURUY.03 / 1205

HRS

Heat recovery unit

HORIZONTAL INSTALLATION These units allow to extract a determined amount of air from the environment and replace it with fresh air. An aluminium plate recovery unit allows effective heat exchange between the expulsion air flow and that of fresh air: the fresh air is pre-heated or pre-cooled in this way, depending on the season, at the cost of the expelled air. The air introduced is filtered before passing through the recovery unit, which is protected from dirtying with a filter of the same type also on the expulsion side. The air introduced can also be post-heated int he versions with hot water heating coil.

Features
Available in 8 sizes and 2 versions: polyethylene/polyester with average thickness of Terminal board on machine to ease the electric HRS: standard version 20 mm. connections and fan control. HRS W: version with additional hot water coil. Condensate drip tray in ABS with low conden- Aluminium plate heat recovery unit housed in It is used when post-heating is necessary. sate drain connection. condensate drip tray. Available in models from 090 to 390. Air filters with G3 efficiency, easily extractable Horizontal installation. laterally, to allow periodical cleaning. Panels realised in Aluzink sheet steel, remova- Double intake centrifugal fans, coupled directly ble for inspection and maintenance. onto electric motors (with single intake for HRS Acoustic and heat insulation of the panels using 030).

92

Accessories
HRS_CS : Section of water cooling/heating - HRS230S ( 400 mm) (with stainless steel condensate drip tray). HRS_SC: Electronic speed regulator. HRS_ED: Regulation shutter. HRS_AT: Anti-freeze thermostat, allows to HRS_S : N 4 circular connection kits for control that the temperature does not fall direct connection of the unit to the circular below a pre-established value. Accessory conduits. installed in the factory, to be requested when - HRS090S ( 315 mm) placing the order for the HRS W version. - HRS160S ( 355 mm) PX: Control panel with switch-over. Wall installation. (from size 090 to 300) PX2: Control panel with switch-over. Wall installation. (from size 090 to 300) Compatibility with the VMF system For further system information please refer to the specific documentation.

HRS 030 HRS090CS HRS160CS HRS190CS HRS230CS HRS300CS HRS390CS HRS090ED HRS160ED HRS190ED HRS230ED HRS090S HRS160S HRS230S HRS030SC HRS060SC HRS01AT * PX PX2

HRS 060

Accessories compatibility HRS 090 HRS 160 HRS 190 HRS 090W HRS 160W HRS 190W

HRS 230 HRS 230W

HRS 300 HRS 300W

HRS 390 HRS 390W

* Accessory installed in the factory, compatible only with HRS W version, to be requested when placing the order.

93

Technical data
Mod. Nominal air ow rate Useful static pressure (1) Total max input Sound Pressure m3/h Pa A dB(A) % kW C % kW C W n n n IP HRS 030 300 45 0,75 43 53 1,5 8,3 46 0,27 29,2 92 x 2 4 2 1(5) 44 F HRS 060 620 55 1,8 51 54 3,1 8,5 48 0,58 29,1 90 x 2 4 2 1(5) 32 F HRS 090 920 65 2,2 50 55 4,7 8,8 48,5 0,88 29,1 147 x 2 4 2 3 44 F HRS 160 1580 70 4,4 53 54 7,9 8,5 47,5 1,48 29,2 350 x 2 4 2 3 44 F HRS 190 1850 77 4,8 52 54 9,2 8,5 47 1,73 29,2 350 x 2 4 2 3 44 F HRS 230 2250 80 5,2 51 54 11,2 8,5 47,5 2,11 29,2 350 x 2 4 2 3 55 F HRS 300 2950 100 8,3 54 51 13,9 7,8 45 2,63 29,3 550 x 2 4 2 3 44 F HRS 390 3920 100 5 56 57 20,6 9,3 50 3,86 29 750 x 2 4 2 1 55 F

Recuperator Efciency (2) Recovered heating capacity (2) Conditioned air temperature (2) Efciency (3) Recovered cooling capacity (3) Conditioned air temperature (3) Fans Power Poles Number of fans Number of speeds Protection rating Isolation class Filters (1) Efciency Air front speed

Electric power supply

230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz

m/s

G3 0,9

G3 1,7 -

G3 2 25x22 2 14 2,5 8,2 33,4 25 8 3/4 2,5

G3 2,3 25x22 2 18 2,5 12,2 30,8 32 14 3/4 2,5

G3 2,7 25x22 2 18 2,5 14,4 30,2 35 15 3/4 2,5

G3 1,8 25x22 2 22 2,5 20,3 33,2 24 17 3/4 5

G3 2,5 25x22 2 22 2,5 24,2 31,3 36 22 3/4 5

G3 2,8 25x22 2 22 2,5 29,9 29,7 38 30 3/4 6,5

Features of the water post-heating coil (HRS W) (4) Geometry mm Rows n Pipes for row n Louver pitch mm Heating capacity kW Air outlet temperature C Air side pressure drop Pa Water side pressure drop kPa Collectors diameter gas Weight kg The performance refers to the following conditions:

(1) Values referring to the nominal air flow rate including recovery unit and filters (2) Winter nominal conditions: - external air temperature: -5C BS, UR 80% - environmental air temperature: 20 C BS, UR 50% - nominal air flow rate (3) Summer nominal conditions: - external air temperature: 32 C BS UR 50% - environmental air temperature: 26 C BS, UR 50% - nominal air flow rate

(4) Heating: - water input temperature: 70 C - t = 10 C - air input temperature: 8 C - nominal air flow rate (5) Can

be adjusted electronically with HRS_SC regulator accessory

Noise pressure level: values referring to 1.5 m from machine intake in free field.

Mod. HRS 030 HRS 060 Features of the water post-heating/cooling coil (HRS_CS) Geometry mm Rows n Pipes for row n Louver pitch mm Heating (6) Heating capacity kW Air outlet temperature C Water ow rate m3/h Water side pressure drop kPa Air side pressure drop Pa Cooling (7) Cooling capacity kW Sensitive cooling capacity kW Air outlet temperature C Water ow rate m3/h Water side pressure drop kPa Air side pressure drop Pa The performance refers to the following conditions:
(6) Heating - air input temperature 12 C, - water input temperature 70 C - t = 10 C - nominal air flow rate

HRS 090 25x22 3 16 2,1 13,2 45,1 1,2 4 29 5,4 3,8 19,2 0,92 4 38

HRS 160 25x22 3 22 2,1 19,4 43,1 1,7 11 38 9,1 6,1 19 1,57 14 48

HRS 190 25x22 3 25 2,1 25,7 44,4 2,3 20 36 12,3 8 18,7 2,04 27 50

HRS 230 25x22 3 26 2,1 33,9 46,9 3 18 25 16,3 10,6 17,9 2,87 26 40

HRS 300 25x22 3 26 2,1 38 43,4 3,3 21 38 18,3 11,9 18,7 3,15 31 52

HRS 390 25x22 3 26 2,1 44,7 40,9 3,9 22 53 21,6 14,3 19,5 3,7 26 56

(7) Cooling - air input temperature 30 C, UR 50% - water input temperature 7 C - t = 5 C - nominal air flow rate

94

Internal layout (configurations available)


ORIENTATION TYPE 01 ORIENTATION TYPE 02

* post-heating coil * post-heating coil

ORIENTATION TYPE 03 STANDARD

ORIENTATION TYPE 04

* post-heating coil * post-heating coil

ORIENTATION TYPE 03 (STANDARD) ORIENTATION TYPE 01 / 02 / 04: TO BE REQUESTED WHEN PLACING THE ORDER * post-heating coil: ONLY AVAILABLE ON HRS W VERSION

Key:
Air expelled Fresh air

Dimensional data (mm)


Mod. HRS Height Length Width Weight (kg) Mod. HRS Height Length Width Weight (kg) Accessories compatibility HRS 030 HRS 060 HRS 090 290 290 410 990 990 1140 750 750 860 41 45 80 HRS 190 500 1380 960 138 HRS 230 600 1650 1230 160 HRS 300 600 1650 1230 174 HRS 160 500 1300 860 125 HRS 390 600 1750 1230 190

A B C

A B C

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

95

Cod.: SHRSUY.02 / 1208

NEW

URX CF
R410A

Heat recovery unit with refrigerant circuit. Air ow from 750 to 3,300 m3/h.

The URX_CF series is the mono-bloc solution designed for the installation requirements typical for public spaces like bars, restaurants, ofces, meeting rooms. The URX_CF units combine in one mono-bloc unit, besides the fan, filter, and heat recovery sections, a heat pump refrigerant circuit with scroll compressors of high output and low noise. The supply air is heated or cooled, based on the season, through the heat pump refrigerant circuit located within the unit and charged with refrigerant R410A. All this allows to have a complete unit, with the automatic operation in each season and capable of combining the required space ventilation requirements with efcient heat recovery. The careful design of the machine combines very compact dimensions, which permit easy installation in false ceilings, with an excellent accessibility for maintaining all the internal components.

Characteristics
VERSIONS ard. Standard horizontal configuration 5 sizes complete with temperature controller REFRIGERANT CIRCUIT: and ready for installation. Heat pump complete with high efficiency low noise scroll compressors, 4 way refrigerant PANELS: cycle reversing valve, evaporator coil, con Self-supporting sandwich panel 20 mm thick denser coil, liquid receiver, liquid separator, in galvanised steel for internal and external double thermostatic expansion valve, liquid surfaces with injected polyurethane insulasight glass (only for models 150, 210, 330), tion (density 40 kg/m3). filter drier, high/low pressure pressostats. HEAT RECOVERY: ELECTRICAL PANEL: Cross flow plate heat exchanger in aluminium The unit is provided with an electrical panel with outputs over 50% in winter conditions. complete with power and control section (included the control for the 3 way valve for FILTERS: the supplementary hot water coil and associ Class G3, 80% gravimetric efficiency, accordated actuators), ensuring the control of all the ing to EN 779, thickness 48 mm, located refrigerant circuit functions. Included are: before the heat recovery both in the supply NTC return air temperature sensor, external and return air flow. air temperature sensor, dampers and actuators in the free-cooling version, pressure switch in CENTRIFUGAL FANS: the supply air filter. Supplied loose is a Double inlet forward curved blades with remote mounted control terminal for autodirect drive motor. Single phase 230V-50Hz matic control of the unit and an outlet to single speed motor. The air flow is controlled, power and control a light to conform with the within +/- 15% of the nominal, through an current regulation for smoking zones. electronic speed controller supplied as standCONDENSATE DRAIN TRAY: Condensate drain tray in aluminium. ACCESSIBILITY: From below for the heat recovery, the filters, the condensate drain tray and the fans.

96

Accessories
MBC casing with 2 row hot water coil to install on the supply air. Includes the three way valve and on-off actuator. FCE free-cooling complete with controls to be added to the existing. Free-cooling operation only works in the summer mode, if the external air temperature is at least 10K lower than the internal air temperature and if the compressor safeties permit it. FGC circular anges. Each accessory consists of a ange to be connected to each unit's rectangular connection. G4F lter efciency G4 MBX casing with single stage electrical heater with shrouded nned elements, with double safety thermostat of manual and automatic reset type, to install on the supply air. 07 07 07 07 07 07 07 10 10 10 10 10 10 10 SUF silencer splitter module, in appropriate casing. The accessory consists of two modules: one for the supply and one for the return.

URCF FCE FGC G4F MBC MBX SUF

15 15 15 15 15 15 15

21 21 21 21 21 21 21

33 33 33 33 33 33

Filters class G3 EN779 in supply and return

Integrated heat pump refrigerant circuit with scroll compressor

Reduced height for false ceiling installations

Unit fitted with temperature controller with unit mounted electrical panel Electronic speed controller supplied as standard, to vary the fan speed

97

Technical data
URX_CF Air flow nominal supply and extract Air flow minimum Available supply static pressure Available extract static pressure Heating capacity total (heat recovery + refrigerant circuit) Total cooling capacity (heat recovery + refrigerant circuit) Heating capacity available Cooling capacity available Heating capacity recovered Cooling capacity recovered Heating capacity refrigerant circuit Cooling capacity refrigerant circuit Total power input winter condition Total power input summer condition Sound pressure level at 1 m Power supply HEAT RECOVERY Efficiency FANS Number of fans Total fans nominal power input Total fans maximum current input FILTERS Classification to EN779 Gravimetric efficiency REFRIGERANT CIRCUIT (COMPRESSOR) Refrigerant Compressor power input winter condition Compressor power input summer condition Maximum compressor current input MBC - HOT WATER COIL (accessory) Number of rows Air side pressure drop (nominal air flow) Heating capacity Heating capacity Water flow rate at nominal conditions Water pressure drop (nominal conditions) Water flow rate at nominal conditions Water pressure drop (nominal conditions) MBX - ELECTRIC HEATING COIL (accessory) Power supply Heating capacity Air side pressure drop (nominal air flow) Number of stages Electric heater current input CONNECTION DIAMETERS Drain pan condensate discharge diameter Water coil connection diameter (m3/h) 1 3 2 4 4 3 2 3 2 3 2 5 (Pa) (Pa) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) dB(A) 07 750 640 278 248 8,8 6,1 2,4 1,4 2,9 0,9 5,9 5,2 2,0 2,6 53 230V/1/50Hz 46,2 2 0,75 4,8 G3 80 R410A 1,3 1,8 8,2 2 11 5 1,9 442 16 336 11 10 1000 850 233 218 10,8 7,3 2,3 1,7 4,3 1,3 6,5 6,0 2,0 2,8 55 230V/1/50Hz 51,2 2 0,84 4,8 G3 80 R410A 1,3 2,1 12,5 2 18 6 2,2 523 22 382 14 15 21 33 1500 2100 3300 1275 1785 2800 239 166 289 233 163 273 15,8 22,8 33,3 10,2 15,0 23,0 3,0 4,8 5,2 2,2 3,4 5,1 7,1 10,1 14,3 2 2,8 4,2 8,7 12,7 19 8,2 12,2 18,8 3,3 4 5,5 3,8 5 6,9 57 59 62 400V/3N/50Hz 400V/3N/50Hz 400V/3N/50Hz 53,2 2 1,02 7,2 G3 80 R410A 1,8 2,3 7 2 23 8,7 3,4 763 9 584 6 53,6 2 1,24 7,2 G3 80 R410A 2,5 3,5 11,1 2 42 10,3 3,7 902 12 638 7 53,6 2 2,5 13,2 G3 80 R410A 3,0 4,4 19,7 2 78 16,8 7,5 1475 31 1306 28

(%)

(kW) (A)

(%)

3 2

(kW) (kW) (A) (n) (Pa) (kW) (kW) (l/h) (kPa) (l/h) (kPa)

6 7 6 6 7 7

(kW) (Pa) (n) (A) (in) (in)

3 10 1 4,6 1 3/4

400V/3/50Hz (separate power supply to the unit) 4,5 6 9 10 10 10 1 1 1 6,8 9,1 13,7 1 3/4 1 3/4 1 3/4

12 10 1 18,2 1 3/4

1. 2. 3. 4.

5.

Power supply fan: 230 V; nominal air ow; without accessories. Operating conditions: return air 26C 50% RH, external air 34C 50% RH. Operating conditions: return air 20C 50% RH, external air -5C 80% RH. This value offer an indication of the capacity produced by the unit net of the capacity used to bring the external air conditions to neutral values (specically 20C with 50% RH in winter and 26C with 50% RH in summer). At 1 m distance in free eld with ducted

6.

7.

connections. Inlet/outlet water temperature 70/60C. Compressor operating. Operating conditions: return air 20C 50% RH, external air -5C 80% RH. Inlet/outlet water temperature 45/40C. Compressor operating. Operating conditions: return air 20C 50% RH, external air -5C 80% RH.

98

Dimensional data (mm)

URX_CF Height Width Depth Weight

A B C

(mm) (mm) (mm) (kg)

07 450 1500 1300 205

10 450 1500 1300 218

15 550 1800 1500 272

21 550 1800 1500 298

33 600 1800 1600 328

Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data .

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

99

Cod.: SURXUY.00 / 1301

NEW

URHE CF
R410A
TECHNOLOGY

High efciency heat recovery unit with refrigerant circuit without an external unit. Air ow from 1,000 to 3,300 m3/h.

HIGH EFFICIENCY

The units from the URHE_CF series represent the high efficiency solution to satisfy the temperature and humidity comfort and ventilation requirements in air conditioning systems that serve public spaces and the commercial sector, such as ofces, bars, restaurants, etc. The URHE_CF units are particularly efficient machines in that they use a high efficiency cross flow plate heat exchanger of high capacity combined with a heat pump refrigerant circuit operating with refrigerant R410A. The use of a high capacity cross ow heat recovery unit permits a signicant reduction in the operating time of the refrigerant circuit throughout the year, thereby reducing to the minimum the electrical energy consumption. The small unit dimensions allow an easy installation even in false ceilings, allowing excellent accessibility for the maintenance of all the internal components. The numerous accessories available on request, for example the high efciency compact lters, the hot water coil or the silencers, complete the functions of the machine which is usually combined to an air conditioning system.

Characteristics
VERSIONS tained constant by the use of an electronic 4 sizes available in horizontal configuration controller.. ENVIRONMENTALLY FRIENDLY: for ground or ceiling void installation. Through the applied technology and the use Unit complete with temperature controller REFRIGERANT CIRCUIT: of ozone friendly refrigerant R410A, the and ready for installation. Heat pump with refrigerant R410A, complete URCHE_CF series is environmentally friendly. with high efficiency low noise rotary or scroll R410A is a refrigerant with high thermodySTRUCTURE AND PANELS: compressors (depending on size), 4 way namic efficiency and this allows, together Structure in aluminium profiles with glass refrigerant cycle reversing valve, evaporator with the use of scroll compressors, to reduce fibre reinforced nylon corner pieces. coil, condenser coil, liquid receiver, thermoCO2 emissions. Sandwich panel 25 mm thick with galvanised static expansion valve, liquid sight glass, filter steel for the internal surface, prepainted for drier, high pressure pressostat, low pressure the external surface with injected polyurepressostat, safety valve, bypass valve (for the thane insulation (density 42 kg/m3). smaller sizes). HEAT RECOVERY: ELECTRICAL PANEL: Cross flow plate heat exchanger in aluminium The unit is provided with an electrical panel optimised to ensure high outputs. complete with power and control section (including the control for the 3 way valve for PLEATED FILTERS: the supplementary hot water coil and associ Class G4, 80% gravimetric efficiency accordated actuators), ensuring the control of all the ing to EN 779, thickness 48 mm, located refrigerant circuit functions. Included are: before the heat recovery both in the supply NTC return air temperature sensor, external and return air flow. air temperature sensor, dampers and actuators in the free-cooling version, pressure switch in CENTRIFUGAL FANS: the supply air filter. Supplied loose is a High pressure forward curved impeller directremote mounted control terminal for autoly coupled to the motor. The air flow is mainmatic control of the unit.

100

Accessories
MBCH hot water coil module modules (only for RHExxB) MBCX electric heater module TPE roof for external installation (only for FCT high efficiency compact filters F7 RHExxB) BIT base for floor mounting (only for TPM roof for external installation of addiRHExxB) tional modules (only for RHExxB) BIM base for floor mounting for additional FCH free-cooling kit RS485 board RS485 MSS n 1 silencer splitter module TPMSS roof for silencer splitter module (only for RHExxB) FGE circular flanges

URHE_CF MBCH MBCX FCT BIT BIM TPE TPM FCH RS485 MSS TPMSS FGE

10 MBCH1 MBCX1 FCT1 BIT1 BIM1 TPE1 TPM1 FCH1 RS485 MSS1 TPMSS1 FGE1

15 MBCH1 MBCX2 FCT1 BIT1 BIM1 TPE1 TPM1 FCH1 RS485 MSS1 TPMSS1 FGE1

25 MBCH1 MBCX3 FCT2 BIT2 BIM1 TPE2 TPM1 FCH2 RS485 MSS2 TPMSS1 FGE1

33 MBCH2 MBCX4 FCT3 BIT3 BIM1 TPE3 TPM1 FCH2 RS485 MSS2 TPMSS2 FGE1

Filters class G4 EN779 in supply and return

High efciency plate heat exchanger

Remote panel (standard)

Inverter for fans standard to maintain constant air ow

High efciency heat pump refrigerant circuit Unit tted with temperature controller with unit mounted electrical panel

101

Technical data
URHE_CF Air flow nominal extract Air flow nominal supply Air flow minimum Available supply static pressure Available extract static pressure Heating capacity total (recovery + refrigerant circuit) Total cooling capacity (recovery + refrigerant circuit) Heating capacity available Cooling capacity available Heating capacity recovered Cooling capacity recovered Heating capacity refrigerant circuit Cooling capacity refrigerant circuit Total power input winter condition Total power input summer condition Sound pressure level Power supply HEAT RECOVERY Efficiency in winter condition Efficiency in summer condition FANS Number of fans Total fans nominal power input Total fans maximum current input Protective rating FILTERS (standard) Classification to EN779 Gravimetric efficiency Classification to EN779 (accessory filters) Additional pressure drop for filters F7 (accessory) REFRIGERANT CIRCUIT (COMPRESSOR) Refrigerant Compressor power input winter condition Compressor power input summer condition Maximum compressor current input CONDENSATE DRAIN TRAY Discharge diameter MBCH - HOT WATER COIL (accessory) Number of rows Air side pressure drop (nominal air flow) Heating capacity Heating capacity Water flow rate at nominal conditions Water side pressure drop (nominal conditions) Water flow rate at nominal conditions Water side pressure drop (nominal conditions) Water coil connection diameter MBCX - Electric heating coil (accessory) Power supply Heating capacity Air side pressure drop (nominal air flow) Number of stages Electric heater current input 1. 2. 3. 4. Power supply fan: 230 V; nominal air ow; without accessories. Operating conditions: return air 26C 50% RH, external air 34C 50%RH. Operating conditions: return air 20C 50% RH, external air -5C 80% RH. This value offer an indication of the capacity produced by the unit net of the capacity used to bring the external air conditions to neutral (%) (Pa) 1 1 3 2 4 4 3 2 3 2 3 2 5 (m3/h) (m3/h) (m3/h) (Pa) (Pa) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) dB(A) ph/V/Hz (%) (%) 10 1000 1000 800 320 320 7,5 6,6 2,8 1,8 3,6 2,2 3,9 4,4 2,2 15 1500 1500 1000 245 245 14,2 8,7 2,9 3,1 10 3,2 4,2 5,5 2,4 25 2500 2500 2000 140 140 24,8 13,8 3,9 3,3 15,3 4,5 9,5 9,3 4,2 33 3300 3300 2500 220 220 33,1 19,8 7 5,4 19,6 5,8 13,5 14 4,9

2,6 2,9 5,1 6,5 66 69 72 75 230V/1/50Hz 230V/1/50Hz 400V/3/50Hz 400V/3/50Hz 82 82 2 0,9 7,6 55 G4 90 F7 35 R410A 1,3 1,7 10 1 2 7 7,7 2,6 673 11 446 3 3/4 80 80 2 0,9 7,6 55 G4 90 F7 59 R410A 1,5 2 11 1 2 18 10,3 4 906 8 700 6 3/4 73 68 2 2,1 10,5 55 G4 90 F7 58 R410A 2,1 2,8 7 1 2 37 15,6 6,5 1363 18 1118 14 3/4 71 65 2 2,1 10,5 55 G4 90 F7 63 R410A 2,8 4,4 10,3 1 2 37 19,7 7,6 1725 32 1311 22 3/4

(kW) (A) IP

3 2

(kW) (kW) (A) (in) (n) (Pa) (kW) (kW) (l/h) (kPa) (l/h) (kPa) (in)

6 7 6 6 7 7

(kW) (Pa) (n) (A) values (specically 20C with 50% RH in winter and 26C with 50% RH in summer)) At 1 m distance in free eld with ducted connections. Inlet/outlet water temperature 70/60C. Compressor operating. Operating conditions: return air 20C 50% RH, external air -5C 80% RH. Inlet/outlet water temperature 45/40C.

400V/3/50Hz (separate power supply to the unit) 5 7,5 12,5 16,5 10 10 10 10 1 1 1 1 7,6 11,4 19 25,1 Compressor operating. Operating conditions: return air 20C 50% RH, external air -5C 80% RH.

5. 6.

7.

102

Dimensional data (mm)

URHE_CF Height Width Depht Weight

A B C

(mm) (mm) (mm) (kg)

10 574 1496 1067 300

15 574 1496 1067 310

25 574 1984 1638 373

33 574 2309 1964 410

Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data .

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

103

Cod.: SURHECFUY.00 / 1301

NEW

ERS
TECHNOLOGY

1. 2. 3.

Heat recovery unit high efciency with static recovery. Air ow from 1,000 to 5,000 m3/h.

HIGH EFFICIENCY

The units of the ERS series are designed to satisfy the temperature and humidity comfort and ventilation requirements typical for public areas like bars, restaurants, ofces, meeting halls. The unit uses a high efciency heat recovery unit made of aluminium plates designed to have the maximum heat exchange efciency. The supply air is thereby pre-heated or pre-cooled, as a function of the season, using the extract air. The intake air is ltered before passing through the heat recovery unit and is protected from dirt with a lter of the same type (G4) also on the extract side. The inverters supplied with the fans permit continuous variable speed control. The high reliability of the components used and the stringent acceptance tests which the unit is submitted to ensure high quality standards, accompanied by simplicity of installation and maintenance of these machines. The different versions available allow the selection of the most appropriate model for the installation requirements.

Characteristics
VERSIONS 5 sizes available for internal or external installation. 2 versions (basis B, with total bypass T) High efficiency counter flow plates in aluminferent types of controllers (factory fitted): ium. - CM: manual air flow control. - CPO: automatic air flow control. FILTERS: Supply and extract side pleated filters class G4 CONDENSATE DRAIN PAN: PANELS: (according to EN779), retained in a metallic Condensate drain pan in aluminium. Framework and sandwich panels 25 mm mesh of 50 mm thickness as standard. thick in galvanised steel for the internal surface and prepainted externally with injected SUPPLY AND EXTRACT FANS: polyurethane insulation (density 42 kg/m3). Double inlet forward curved impeller with Base in continuous profile galvanised steel. direct drive motor. Single phase 230V-50Hz The removal of the panels to inspect the intersingle speed motor supplied with electronic nal components is made as easy as possible. controller for varying the frequency. The unit is accessible on both sides. ELECTRONIC CONTROLLER: HEAT RECOVERY: It is possible to supply the unit with four dif-

104

Accessories
HBX electric pre-heat coil. HFT high efficiency bag filter. HBW supplementary water coil. HBC supplementary direct expansion R407C coil. HBA supplementary direct expansion R410A coil. TP protective roof. HPF filters pressure switch. V3V 3-way valve. FCR intake circular flange. GAR intake anti-vibration connection. HSR intake damper. CAR intake hood. BLM supply grille. FCE extract circular flange. GAR intake anti-vibration connection supply air. GAE intake anti-vibration connection extract air. GMR discharge anti-vibration connection supply air. GME discharge anti-vibration connection extract air. BLE extract grille. CM manual air flow controller. CPO constant air flow controller. CPV constant pressure controller (from fan). CPS constant pressure controller (from sensor).

ERS HFT, HBW, HBC, HBA, TP, CAR, HSR FCR, FCE, GAR, GAE, BLE HPF V3V CM, CPO, CPV, CPS HBX

10 B 10 10 HPF V3V 10 10

20 B 10 20 T 10 10 B 30 30

30 T 30 20 HPF V3V B 40 40

40 T 40 30 B 50 40

50 T 50 40

10 20

10 10

30 30

10 20

40 40

30 30

50 50

40 40

High pressure fan tted as standard with inverter

If the unit is tted with electronic controller the functions are controlled through the LCD on the remote mounted panel

The T versions has bypass for freecooling

High efciency counter ow heat exchanger

105

Technical data

ERS VERSION Air flow nominal supply and extract Maximum available external static pressure supply and extract Heating capacity recovered Recovery winter efficiency Cooling capacity recovered Recovery summer efficiency Total number of fans Power input per fan Maximum current input per fan Power supply Sound pressure level HBW Water coil Total cooling capacity Heating capacity Heating capacity HBC Direct expansion coil R407C Total cooling capacity Heating capacity HBA Direct expansion coil R410A Total cooling capacity Heating capacity

1 1 2 2

(m3/h) (Pa) (kW) (%) (kW) (%) (n) (kW) (A) V/h/Hz dB(A)

10 20 30 40 50 B B T B T B T B T 1.000 2.000 1.000 3.000 2.000 4.000 3.000 5.000 4.000 340 340 410 280 360 460 280 350 410 8,8 17,7 9 26,5 17,8 35,1 26,5 44,1 35,5 82,4 82,4 83,9 82,4 83,2 82 82,4 82,4 82,8 2,1 4,2 2,1 6,3 4,2 8,3 6,3 10,4 8,4 69,2 69,2 70,4 69,2 69,9 68,8 69,2 69,2 69,5 2 4 2 2 4 4 2 4 4 1 2 1 2 2 4 2 4 4 4,4 8,8 4,4 8,4 8,8 16,8 8,4 16,8 16,8 230V/1/50Hz 24,8 10 10,7 12,9 6,8 10 11,1 8,4 10 12 8,5 26,9 10 17,6 21,5 11,4 10 15,9 13,6 10 18,1 13,7 23,3 10 10,7 12,7 6,7 10 11,1 8,3 10 12,1 8,3 29,3 30 28,4 33,4 17,7 30 24,4 20,8 30 27,7 20,9 25,3 30 21,6 24,6 13 30 20,1 15,6 30 22,2 15,7 31,6 40 37,2 44 23,4 40 31,8 27,4 40 36,2 27,6 32 40 30,6 35,5 18,9 40 27,6 22,5 40 30,9 22,6 36,5 50 48,9 56,7 30,1 50 41,5 35,1 50 47 35,3 33,3 50 42,2 47,9 25,4 50 37,5 30 50 41,8 30,2

3 4 5 6 7 8 9

(kW) (kW) (kW) (kW) (kW) (kW) (kW)

1.

Equal supply and extract air flows; inlet temperature external air 10C, 90% RH; ambient air temperature 22C, 50% RH. Performance refers to: equal supply and extract air flows; inlet temperature external air 35C, 50% RH; ambient air temperature 26C, 50% RH. Sound pressure at 10m in free field, with directivity factor 2. Coil water inlet temperature 7C; inlet-outlet temperature differential 5K. Inlet temperature external air 35C, 50% RH; ambient air temperature 26C, 50% RH. Coil water inlet temperature 70C; inlet-outlet coil 5.

differential temperature 10K. Inlet temperature external air 10C, 90% RH; ambient air temperature 22C, 50% RH. Coil water inlet temperature 45C; inlet-outlet temperature differential 5K. Inlet temperature external air 10C, 90% RH; ambient air temperature 22C, 50% RH. Evaporating temperature 5C; condensing temperature 50C. Inlet temperature external air 35C, 50% RH; ambient air temperature 26C, 50% RH. Evaporating temperature 0C; condensing temperature 50C. Inlet temperature external air

10C, 90% RH; ambient air temperature 22C, 50% RH. 8. Evaporating temperature 5C; condensing temperature 50C. Inlet temperature external air 35C, 50% RH; ambient air temperature 26C, 50% RH. Evaporating temperature 0C; condensing temperature 50C. Inlet temperature external air 10C, 90% RH; ambient air temperature 22C, 50% RH.

2.

9.

3.

6.

4.

7.

106

Dimensional data (mm)

ERS Height Width Depth Weight A B C (mm) (mm) (mm) (kg)

10 1.900 900 1.300 290

20 1.900 900 1.300 315

30 1.900 1.300 1.300 373

40 1.900 1.600 1.300 453

50 1.900 2.100 1.300 531

Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data .

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

107

Cod.: SERSUY.00 / 1301

NEW

ERSR
TECHNOLOGY

Heat recovery unit with high efficiency rotary heat exchanger. Air flow from 1,000 to 30,000 m3/h.

HIGH EFFICIENCY

The units of the ERSR series are designed to satisfy the temperature and humidity comfort and ventilation requirements typical for public areas. The units are characterised by a high efciency low pressure drop rotary heat exchanger (with the option of having a hygroscopic treatment on its surfaces). The heat recovered by this exchanger ensures the contribution from the air conditioning system is kept to a minimum: in this way a highly cost effective operation is achieved. Signicant economic savings are ensured also by the use of plug fans with electronically controlled motors (up to size 17) or with high efciency inverter controlled motors. The unit is plug & play, being supplied with an electronic controller and unit mounted electrical power panel. The special control software is capable of maximising the use of the unit in energetically favourable conditions.

Characteristics
VERSIONS 7 sizes available for internal or external installation. 2 versions: - with rotary heat exchanger (T) - with hygroscopic rotary heat exchanger (H) STRUCTURE: Support structure and sandwich panel with 50 mm thickness in galvanised sheet steel for the internal surface and prepainted for the external surface with mineral wool insulation (density 50 kg/m3). On demand other types of panels can be provided. Base in continuous profile galvanised steel. The sizes 07 and 09 are mono-bloc whilst the other sizes are divided into sections. The unit is accessible from both sides. HEAT RECOVERY: Rotary (with optional hygroscopic material) with high efficiency and low pressure drop. FILTERS: Supply and extract air soft bag filters of class F7 (according to EN779) are supplied as standard. All filters are side withdrawal and are supplied as standard with a differential pressure switch to indicate a dirty filter. SUPPLY AND EXTRACT FANS: Plug fan with backward curved impeller with direct drive motor, electronically controlled for sizes 07-17 and with inverter for sizes 21-24. ELECTRONIC CONTROLLER: The unit is supplied with an electrical power panel unit mounted and with a controller specifically designed to reduce energy consumption. Serial port provided as standard for communicating on RS485 with MODBUS Master/ Slave protocol.

108

Accessories
RSR recirculation section/damper. RBF chilled water coil module with 3 way valve. RBC hot water coil module with 3 way valve. RBP chilled water coil and hot water reheat coil module with 3 way valves. RE electric coil module. VRC condensate drain pan. MSS silencer splitter module. TDP protective roof.

ERSR UNIT ACCESSORIES FRR (Flange) GAR (Rectangular anti-vibration connection) HSR (Intake air damper) RSR (Recirculating damper module) HG4 (Panel filters G4) TDP (Protective roof) VRC (Condensate drain pan) ACCESSORY MODULES RBC (Hot water coil module) RBF (Chilled water coil module) RE (Electric heater module) RBP (Chilled water and re-heat coil module) MSS (Silencer splitter module) ACCESSORY MODULES WITH ROOF RBCT (Hot water coil module) RBFT (Chilled water coil module) RET (Electric heater module) RBPT (Chilled water and re-heat coil module) MSST (Silencer splitter module)

07 FRR09 GAR07 HSR07 HG407 TDP07 VRC07 RBC07 RBF07 RE0706 RBP07 MSS07 RBC07T RBF07T RE0706T RBP07T MSS07T

09 FRR09 GAR09 HSR09 HG409 TDP09 VRC09 RBC09 RBF09 RE0909 RBP09 MSS09 RBC09T RBF09T RE0909T RBP09T MSS09T

12 FRR12 GAR12 HSR12 HSR12 HG412 TDP12 VRC12 RBC12 RBF12 RE1218 RBP12 MSS12 RBC12T RBF12T RE1218T RBP12T MSS12T

15 FRR15 GAR15 HSR15 RSR15 HG415 TDP15 VRC15 RBC15 RBF15 RE1524 RBP15 MSS15 RBC15T RBF15T RE1524T RBP15T MSS15T

17 FRR17 GAR17 HSR17 RSR17 HG417 TDP17 VRC17 RBC17 RBF17 RE1730 RBP17 MSS17 RBC17T RBF17T RE1730T RBP17T MSS17T

21 FRR21 GAR21 HSR21 RSR21 HG421 TDP21 VRC21 RBC21 RBF21 RE2148 RBP21 MSS21 RBC21T RBF21T RE2148T RBP21T MSS21T

24 FRR24 GAR24 HSR24 RSR24 HG424 TDP24 VRC24 RBC24 RBF24 RE2463 RBP24 MSS24 RBC24T RBF24T RE2463T RBP24T MSS24T

Plug fans supplied with electronic control motor or inverter, depending on size Bag filters class F7 standard

Rotary heat exchanger of high efciency and low pressure drop

Structure made of an aluminium frame and sandwich panel 50 mm thick

109

Technical data

ERSR VERSION Air flow nominal supply and extract Maximum available static pressure supply and extract Total nominal power input Maximum air flow supply and extract Maximum total power input Total heating capacity recovered Sensible heating capacity recovered Recovery winter efficiency Total cooling capacity recovered Sensible cooling capacity recovered Recovery summer efficiency Total number of fans Sound power level Unit power supply RBC Hot water coil Heating capacity Water flow rate Water side pressure drop RBF Chilled water coil Total cooling capacity Sensible cooling capacity Water flow rate Water side pressure drop

2 2 2 3 3 3

(m3/h) (Pa) (kW) (m3/h) (kW) (kW) (kW) (%) (kW) (kW) (%) (n) dB(A) V/h/Hz

07 T 1.100 420 0,33 2.000 0,82 10,7 7,4 80 2,8 2,7 80 2 65,6

09 T 1.950 660 0,48 4.370 2,04 19 13,1 80 4,9 4,7 80 2 67

12 T 3.700 1.100 1,06 5.880 6,09 36 24,9 80 9,3 9 80 2

15 17 21 24 T T T T 5.950 7.800 12.200 16.100 1.120 1.040 1.440 1.530 1,69 2,13 3,49 3,85 10.650 14.800 24.750 31.350 8,78 10,2 22,4 30,4 57,9 75,9 118 156 40,1 52,5 82,1 108 80 80 80 80 14,9 19,5 30,5 40,3 14,4 18,9 29,6 39 80 80 80 80 2 2 4 78 4 79

75,3 76,7 78 400V/3N/50Hz 27,4 2,3 8 34,7 13,9 6 7 46,7 4 7 59,8 23,9 10,3 23 60,1 5,2 11 80 32 13,7 33

4 4 4 5 5 5 5

(kW) (m3/h) (kPa) (kW) (kW) (m3/h) (kPa)

9,5 0,8 9 10,5 4,1 1,6 15

16,9 1,4 8 19,5 7,6 2,9 8

95,8 8,4 16 127,4 51 21,9 34

130,4 11,3 20 171,3 68,5 29,5 3,2

For the performance of the version H contact the factory


1. At nominal air ow rate conditions and available static pressure of 100 Pa. Heating Performance refers to: equal supply and extract air ow; external air inlet temperature 5C, 80% RH; ambient air temperature 20C, 50% RH. Cooling Performance refers to: equal supply and extract air ow: external air inlet temperature 35C, 50% RH; ambient air temperature 26C, 50% RH. 4. Coil water inlet temperature 70C; inlet-outlet coil differential temperature 10K. Coil inlet air temperature 15C; water pressure drops do not include the 3 way valve (standard). Coil water inlet temperature 7C; inlet-outlet temperature differential 5K. Coil inlet air temperature 28C, 75% RH; water pressure drops do not include the 3 way valve (standard).

2.

5.

3.

Sound power level of the supply fan not ducted with external static pressure equal to 0 Pa.

110

Dimensional data (mm)

ERSR Height (including base H=120mm) Width Length Weight A B C mm mm mm kg

07 1,375 895 965 240

09 1,535 1,005 1,285 340

12 2,045 1,375 1,445 570

15 2,365 1,695 1,765 820

17 2,365 1,855 2,085 1,010

21 3,005 2,335 2,405 1,610

24 3,005 2,665 2,725 1,980

Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data .

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

111

Cod.: SERSRUY.00 / 1301

03

ANL 020/202
R410A
Aermec participates in the EUROVENT Certification Programme: LCP/A/P/R. The products concerned appear in the EUROVENT site www.eurovent-certification.com.

Air cooled water chillers, heat pumps and condensing units with axial fans: Cooling capacity from 5,65 43,70 kW Heating capacity from 6,27 44,9 kW

STANDARD VERSION PUMP OPTION FOR WATER ABILITY TO PRODUCE PUMP DOMESTIC HOT WATER OPTION FOR WATER (D.H.W.) PUMP AND BUFFER TANK OPTION FOR HIGH HEAD
Features
Available in 11 sizes Cooling only, heat pump, and condensing unit models Available in 5 versions: ANL: Standard Version ANL P : Version fitted with water pump, expansion vessel, water filter ANL N: Version with high head pump ANL A : Version fitted with water pump, expansion vessel, water filter, and buffer tank ANL Q: Version with high head pump and ation buffer tank Metallic protective cabinet with anti-corro ANL C: Condensing unit (without evaporator) sion polyester paint High efficiency scroll compressors with low power input Differential pressure switch / flow switch as standard supply Electronic controller (Modu_control) High efficiency heat exchangers Axial flow fan units for extremely quiet oper-

Accessories
BDX: Condensate drip tray for outdoor unit. AERSET DCPX: Low temperature device for correct The AERSET accessory allows the automatic cooling mode operation with ambient temcompensation of the operating setpoint of the unit peratures from less than 20 C down to - 10 to which it is connected, based on a 0-10V MODC. BUS input signal. Mandatory accessory: AER485 Standard in the version with desuperheater or MODU-485A DRE: Electronic soft starter device reducing AERWEB300: The AERWEB option allows starting current by about 30%. Only available remote control of a chiller through a standfor three-phase models. Factory fitted only. ard PC and an ethernet connection with a KR: Anti-freeze electric heater for the plate standard browser; 4 versions available: heat exchanger, not available for sizes 020AAERWEB300-6: Web server to monitor and HA to 040A-HA. Factory fitted only. remote control maximum 6 units on RS485 KRB: Electric anti-freeze heater for the base. network; Prevents the formation of ice on the base. AERWEB300-18: Web server to monitor and Factory fitted only. remote control maximum 18 units on RS485 PR3: Simplified remote panel. Permits control network; of the basic unit functions (on/off and change AERWEB300-6G: Web server to monitor and of operating mode, diagnostics and alarm remote control maximum 6 units on RS485 reset). Maximum distance permitted is 150 m network with integrated GPRS modem; with screened cable. AERWEB300-18G: Web server to monitor and MODU-485A: RS-485 interface for superviremote control maximum 18 units on RS485 sion systems with MODBUS protocol. network with integrated GPRS modem. MULTICONTROL: Allows the simultaneous control of several chillers or heat pumps (up to 4) fitted with our MODUCONTROL controller and installed in the same hydraulic system. For complete control the following accessories are available: SPLW: System water temperature sensor. In most cases the loose supplied sensors for each chiller/ heat pump are sufficient. In cases of a common flow/return header this sensor can be used to control the common system supply water temperature for the chillers connected to the header, or it can be used for temperature monitoring. SDHW: Domestic hot water temperature sensor. Used with the storage tank to control the temperature of water produced. RA: Anti-freeze electric heater for the buffer tank. Factory fitted only. VT: Anti-vibration mounts. Compatibility with the VMF system For further system information please refer to the specific documentation.

114

Accessory compatibility

ANL PR3 MODU-485A AERSET AERWEB300 SPLW SDHW DRE 1 DCPX VT RA 3 BDX KR2 3 KRB3 3

vers () - H - C Alls Alls Alls Alls Alls () - H - C () - C H () - H - HP - C A A () / P A () / P A

20 50 51 9 9 5 5 2 -

25 50 51 9 9 5 5 2 -

30 50 51 9 9 5 5 2 -

40 50 51 9 9 5 5 2 -

50 5 50 51 9 15 5 6 2 2 -

70 5 50 51 9 15 5 6 2 2 -

80 5 50 51 9 15 5 6 2 2 -

90 5 50 51 9 15 5 6 2 2 -

102 5 x2 52 53 15 15 2 2

152 5 x2 52 53 15 15 2 2

202 5 x2 52 53 15 15 2 2 1 Only available for 400V/3N power supply. Factory fitted only. 2 Not available for sizes ANL 020040A | HA. 3 Factory fitted only. x2 Quantity to be ordered DCPX Standard in the version with desuperheater

MULTICONTROL Alls

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most particular of system requirements.

Configuration fields:
1 2 3 4 5 6 7 8 9 10 11 12 13 | | | | | | | | | Code | Model | Heat recovery | Field of use | Power supply | | | | Size Version Coil fins Evaporator Code ANL Size 020, 025, 030, 040, 050, 070, 080, 090, 102, 152, 202 Model Cooling only H Heat pump Version Standard P With pump N With high pump from size 102 to 202 A With pump and buffer tank Q With buffer tank and high head pump from size 050 to 202 Heat recovery: Without heat recovery D With desuperheater* Coil fins Aluminium R Copper possible for H version for sizes from 102 to 202 S Tinned copper For sizes 102 - 152 - 202 only in heat pump models V Treated aluminium (epoxy coated) epoxy paint for sizes 102 - 152 - 202 in heat pump models cataphoresis treatment for sizes 102 - 152 - 202 in cooling only models Field of use Standard leaving water temperature down to 4C Y Z Low leaving liquid from 4C down to up to 0C Low leaving liquid from 0C down to -6C

Evaporator Standatd C Condensing unit (without evaporator) Power supply M 230V/1/50Hz only for sizes 020 to 040 400V/3N/50Hz Attention: Z-Y = these options apply exclusively to cooling only models standard options are shown by symbol heat pump model not available as condensing unit version (field 7: option H; field 12: option C) single phase power supply (field 13: option M) is available only for sizes 020 - 025 - 030 - 040 * The desuperheater is available for sizes from 050 to 090 only with buffer tank, whilst sizes from 100 to 200 are available in all versions. Desuperheater is incompatible with the low temperature options, with the condensing unit version, and for dimensional reasons even with the option Q. Configuration code example: ANL090HAR This is a an ANL unit, size 090, heat pump model, with buffer tank and pump, with copper condenser coil, with evaporator, and with electrical panel for compressors with motors 3N~ 400V 50Hz. Note that as each option is precisely identified, it is not necessary to specify standard options (indicated by ) in the configuration code.

115

Technical Data
Model Cooling capacity P|A N|Q P|A N|Q P|A P|A N|Q ALL P|A N|Q P|A N|Q P|A N|Q kW kW kW kW kW kW A A A A A l/h kPa kPa kPa W/W W/W W/W 020 5,65 5,71 1,89 1,92 6,43 3,7 7,20 4,5 980 21 60 3,00 2,98 3,43 3,5 020H 6,27 6,19 1,98 1,98 6,61 3,80 7,38 4,57 3,17 3,12 1066 33 58 5,64 5,71 1,90 1,92 6,43 3,70 7,20 4,47 2,97 2,98 980 30 60 025 6,15 6,21 2,05 2,07 7,3 4,2 8,07 4,97 1066 21 60 3,00 3,00 3,43 3,54 025H 7,08 6,98 2,20 2,19 7,65 4,40 8,43 5,18 3,22 3,19 1204 37 56 6,14 6,21 2,06 2,07 7,30 4,20 8,07 4,97 2,98 3 1066 31 60 030 7,44 7,52 2,52 2,52 8,17 4,7 8,96 5,49 1290 22 59 2,96 2,98 3,4 3,55 030H 8,49 8,37 2,71 2,68 9,39 5,40 10,19 6,20 3,13 3,12 1445 37 55 7,43 7,52 2,53 2,52 8,17 4,70 8,96 5,49 2,93 2,98 1290 32 59 040 9,53 9,64 3,32 3,30 10,78 6,2 11,59 7,01 1651 24 55 2,87 2,92 3,33 3,48 040H 10,70 10,56 3,28 3,23 11,83 6,80 12,64 7,61 3,26 3,27 1823 34 51 9,52 9,64 3,33 3,30 10,78 6,20 11,59 7,01 2,86 2,92 1651 30 55 050 13,31 13,47 13,73 4,12 4,10 4,18 8,7 10,06 9,66 2305 25 82 160 3,23 3,28 3,28 3,74 3,85 3,66 050H 14,12 13,93 13,67 4,42 4,37 4,45 9,50 10,87 10,48 3,20 3,19 3,07 2408 34 82 159 13,29 13,47 13,73 4,14 4,10 4,18 8,70 10,06 9,66 3,21 3,28 3,28 2305 34 82 160 070 16,39 16,59 16,9 4,98 4,92 5,01 9,7 11,11 10,74 2838 26 81 159 3,29 3,37 3,37 3,82 3,97 3,77 070H 17,44 17,20 16,92 5,04 4,95 5,04 10,30 11,72 11,36 3,46 3,48 3,36 2976 36 79 157 16,37 16,59 16,87 5,01 4,94 5,02 9,70 11,11 10,74 3,26 3,36 3,36 2838 35 80 158 080 20,35 20,60 20,9 6,48 6,39 6,48 12,2 13,68 13,33 3526 34 69 144 3,14 3,22 3,22 3,65 3,8 3,61 080H 22,40 22,11 21,79 6,50 6,36 6,46 12,90 14,40 14,06 3,45 3,48 3,37 3818 48 65 137 20,32 20,59 20,9 6,51 6,39 6,48 12,20 13,68 13,33 3,12 3,22 3,22 3526 44 69 144 090 22,14 22,40 22,72 6,79 6,69 6,79 12,8 14,30 13,96 3836 35 66 140 3,26 3,35 3,35 3,71 3,95 3,75 090H 24,46 24,10 23,77 7,11 6,91 7,02 13,80 15,33 15,00 3,44 3,49 3,39 4162 65 61 132 22,06 22,4 22,72 6,87 6,69 6,79 12,80 14,30 13,96 3,21 3,35 3,35 3836 60 66 140 102 26,34 26,93 27,07 8,06 8,07 8,46 15,57 16,74 17,77 4575 58 84 140 3,27 3,34 3,20 3,85 3,96 3,61 102H 29,31 28,69 28,56 8,87 8,87 9,30 17,00 18,18 19,25 3,30 3,23 3,07 4988 69 70 117 25,75 26,33 26,47 8,82 8,84 9,23 15,60 16,73 17,75 2,92 2,98 2,87 4472 55 84 140 152 32,69 33,48 33,7 10,31 10,53 10,58 18,81 20,59 21,18 5676 61 115 185 3,17 3,18 3,18 3,99 3,94 3,74 152H 35,35 34,55 34,34 10,45 10,67 10,72 19,00 20,83 21,44 3,38 3,24 3,20 6020 68 100 174 31,71 32,47 32,65 10,48 10,72 10,77 18,80 20,56 21,15 3,02 3,03 3,03 5504 57 115 185 202 42,60 43,49 43,7 13,53 13,79 13,83 24,67 26,72 27,39 7396 68 90 158 3,15 3,15 3,16 3,94 3,82 3,62 202H 45,78 44,90 44,64 13,78 14,06 14,08 25,00 27,07 27,76 3,32 3,19 3,17 7795 78 68 141 40,57 41,41 41,63 14,28 14,57 14,60 24,70 26,67 27,33 2,84 2,84 2,85 7042 62 91 159

Total power input 230V/1 400V/3N 230V/1 400V/3N 400V/3N

Total input current

Water flow rate Pressure drop Available head EER

ESEER

Heating capacity

Total input power 230V/1 400V/3N 230V/1 400V/3N 400V/3N

Total input current

COP Water flow rate Pressure drop Available head Cooling capacity

Total input power 230V/1 400V/3N 230V/1 400V/3N 400V/3N

Total input current

EER Water flow rate Pressure drop Available head

P|A N|Q H P|A N|Q H H P|A P|A N|Q H P|A N|Q ALL H P|A N|Q P|A N|Q H P|A N|Q H H P|A P|A N|Q H P|A N|Q ALL H P|A N|Q

kW kW kW kW kW kW A A A A A W/W W/W W/W l/h kPa kPa kPa kW kW kW kW kW kW A A A A A W/W W/W W/W l/h kPa kPa kPa

Data declared in accordance with UNI EN 14511: 2011 COOLING Evaporator water inlet Evaporator water outlet External air temperature 12C 7C 35 C HEATING Condenser water inlet 40C Condenser water outlet 45C External air temperature 7 C db / 6 C wb COOLING version C Evaporating temperature External air temperature 5C 35 C

116

Technical Data
Cooling capacity Total input power Total input current EER Connections Line gas Line liquid DATA FOR ALL VERSIONS Electrical data 230V/1 400V/3N 230V/1 400V/3N 400V/3N 230V/1 400V/3N 230V/1 400V/3N 400V/3N P|A P|A N|Q P|A P|A N|Q A A A A A A A A A A 230V/1 400V/3N ALL kW kW A A W/W 020C 5,7 1,85 9,50 3,70 3,08 15,88 9,52 020 16,5 6,0 17,32 6,82 59,5 26,5 60,32 27,32 025C 6,0 2,05 10,00 4,20 2,93 15,88 9,52 025 16,5 6,0 17,33 6,83 62,5 32,5 63,33 33,33 030C 7,5 2,5 13,00 4,70 3,00 15,88 12,7 030 19,7 6,7 20,54 7,54 83,7 35,7 84,54 36,54 040C 9,6 3,3 16,30 6,30 2,91 15,88 12,7 040 23,7 8,7 24,56 9,56 98,7 48,7 99,56 49,56 050C 13,7 4,1 8,90 3,34 22 15,88 050 11,3 12,65 12 65,3 66,65 66,11 070C 16,8 5 9,90 3,36 22 15,88 070 13,5 14,9 14 75,3 76,7 76,17 IP24 scroll 1/1 R410A n l n m3/h dB(A) dB(A) 1 1" 25 1 2500 30 61 1 1" 25 1 2500 30 61 1 1" 35 1 3500 37 68 1 1" 35 1 3500 37 68 1 1" 75 2 7200 38 69 1 1" 75 2 7200 38 69 1 1" 75 2 7300 38 69 1 1" 75 2 7200 37 68 1 1" 100 2 14000 44 76 1 1" 100 2 13500 45 77 1 1" 100 2 13500 46 78 080C 20,8 6,5 12,40 3,20 22 15,88 080 16,3 17,76 17 102,3 103,76 103,25 090C 22,5 6,8 13,10 3,31 28 15,88 090 17,3 18,79 18 96,3 97,79 97,28 102C 26,9 8,0 16,0 3,36 28 15,88 102 22,0 23,03 24 76,0 77,03 77,93 152C 33,4 10,2 19,3 3,27 28 15,88 152 26,0 27,73 28 87,0 88,73 89,12 202C 43,7 13,5 25,3 3,24 28 15,88 202 32,0 33,95 34 117,0 118,95 119,40

Maximum current (FLA)

Starting current (LRA)

Protection rating Compressors Number / circuits Capacity control Refrigerant Heat exchanger system side Number hydraulic connections Buffer tank Capacity Fans Number Air flow rate cooling mode Sound data Sound pressure Sound power

n/n % type

1/1

1/1

1/1

1/1 1/1 0-100

1/1

1/1

2/1

2/1 0-50-100

2/1

IN|OUT

Sound power Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

Sound pressure Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Dimensions (mm)
DIMENSIONS - WEIGHT 020 025 030 040 050 070 080 090 868 868 1000 1000 1252 1252 1252 1252 |P|C mm 868 868 1015 1015 1281 1281 1281 1281 Height (A) A mm 1281 1281 1281 1281 Q mm 900 900 900 900 1124 1124 1124 1124 |P|C mm 1124 1124 1124 1165 1165 1165 1165 Width (B) A mm 1124 1165 1165 1165 1165 Q mm |P|C mm 310/354* 310/354* 310/354* 310/354* 384/428* 384/428* 384/428* 384/428* Depth (C) 550 550 550 A mm 384/428* 384/428* 384/428* 384/428* 550 550 550 550 550 Q mm Cooling only model 75 75 86 86 120 120 120 156 kg 77 77 91 91 127 127 163 163 P kg 99 99 103 103 147 147 147 183 Weight A kg 151 151 187 187 Q kg 70 70 78 78 110 110 141 141 C kg Heat pump model 75 75 86 86 120 120 120 156 kg 77 77 91 91 127 127 163 163 P kg Weight 99 99 103 103 147 147 147 183 A kg 151 151 187 187 Q kg
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

102
1450

152
1450

202
1450

020 040 * without feet / with feet


1750 1750 1750
C B

750

750

750

270 288 338

293 314 364

329 350 400

050 090
B A

295 313 363 423

322 343 393 447

358 379 429 457


C

102 - 152 - 202

117

Cod.: SANLUY.17/ 1301

NEW

ANL 290/650
cooling only

Air cooled chillers Axial fans Cooling capacity from 55 to 133 kW

R410A
Aermec participate in the EUROVENT program: LCP/A/P/R. the products are present on the site www.eurovent-certification.com

COOLING ONLY VERSION VERSION WITH PUMP


Features
Available in 7 sizes. Cooling only. Monocircuit. R410A Gas. Available in 2 version: - () Standard version ANL 580/650. - (L) Low noise vesion ANL 290/650. High efficiency scroll compressors Flow switch as standard supply.  Low and high pressure transducers as standard supply. Cooling mode: Up to 43C (ANL 290/400). Up to 44C (ANL 580/650).

VERSION WITH PUMP AND STORAGE TANK

High efficiency exchangers. Axial fans with low sound level. Versions with hydronic kit (pump/pomp-storage tank) options complete with water filter, flow switch, expansion tank and anti-freeze electric heater). Pump+Pump standby option controlled by manual switch. Electronic controller (Modu_control). Metallic protective cabinet with anti-corrosion polyester paint. Microprocessor control system -  Control from the entering water temperature, with the possibility of selecting con-

trol of the leaving water temperature -  Summer condensation control with 0-10V modulating signal depending on pressure, compensated according to the outside air temperature (with DCPX accessory) - Intelligent defrosting to decay of pressure. - Automatic rotation of compressors and pumps based on operating hours. - Load limiting safety control. - Automatic reset of alarms before total block. - Alarm history.

Accessories
DCPX: Low temperature device for correct cooling mode operation with ambient temperatures from less than 20 C down to - 10 C. DRE: (THIS ACCESSORY MUST THEREFORE BE SPECIFIED WHEN THE ORDER IS PLACED, CAN ONLY BE APPLIED IN THE FACTORY) current reduction of about, 26% for two circuit units. Only available for three-phase models. PR3: Simplified remote panel. Permits control of the basic unit functions (on/off and change of operating mode, diagnostics and alarm reset). Maximum distance permitted is 150 m with screened cable. AERSET: accessory allows the automatic compensation of the operating setpoint of the unit to which it is connected, based on a 0-10V MODBUS input signal. Mandatory accessory: AER485 or MODU-485A MODU-485A: RS-485 interface for supervision systems with MODBUS protocol. AERWEB300: The AERWEB option allows remote control of a chiller through a standard PC and an ethernet connection with a standard browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control maximum 6 units on RS485 network; AERWEB300-18: Web server to monitor and remote control maximum 18 units on RS485 network; AERWEB300-6G: Web server to monitor and remote control maximum 6 units on RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control maximum 18 units on RS485 network with integrated GPRS modem. MULTICONTROL: Allows the simultaneous control of several chillers or heat pumps (up to 4) fitted with our MODUCONTROL controller and installed in the same hydraulic system. For complete control the following accessories are available: SPLW: System water temperature sensor. In most cases the loose supplied sensors for each chiller/heat pump are sufficient. In cases of a common flow/return header this sensor can be used to control the common system supply water temperature for the chillers connected to the header, or it can be used for temperature monitoring. VT: Anti-vibration mounts. GP: Protects the external coil from blows. RIF (THIS ACCESSORY MUST THEREFORE BE SPECIFIED WHEN THE ORDER IS PLACED, CAN ONLY BE APPLIED IN THE FACTORY): Current rephaser. Connected in parallel to the motor, it allows a reduction of the absorbed current about 10%. COMPATIBILITY WITH THE VMF SYSTEM. For further system information please refer to the specific documentation.

118

Accessory compatibility
ANL DCPX (version with standard fan "") DCPX (version with high static pressure fan "M") DRE PR3 AERSET MODU-485A AERWEB-300 MULTICONTROL SPLW VT (00) VT (P1-P2-P3-P4) VT (01-02-03-04) GP RIF vers /L /L /L /L /L /L /L /L /L /L /L /L /L /L 290 58 62 10(x2) 17 13 13 GP3 32 300 58 62 10(x2) 17 13 13 GP3 32 340 58 62 15(x2) 17 13 13 GP3 42 400 58 63 25(x2) 17 17 13 GP3 42 580 83 83 30(x2) 11 11 11 GP2 (x2) 50 620 83 83 30(x2) 11 11 11 GP2 (x2) 72 650 83 83 30(x2) 11 11 11 GP2 (x2) 51

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most particular of system requirements. Code

1,2,3 4,5,6

DESCRIPTION ANL
SIZE

13

POWER SUPPLY

400V-3N -50 Hz 14 SOFT START Without Soft Start S With Soft Start 15-16 00 01 02 03 04 P1 P2 P3 P4 SORAGE TANK/PUMP Without pump or storage tank Low head pump and buffer tank Single and standby low head pump and buffer tank Single high head pump and buffer tank Single and standby high head pump and buffer tank Low head pump Single and standby low head pump Single high head pump Single and standby high head pump

290-300-340-400-580-620-650 7
FIELD OF USE

Standard with produced water down to +4 C Y Low leaving water up to -6 C X Electronic thermostatic valve temperature of water produced up to +4C (for different temperatures please contact us) 8 MODEL Cooling only C Condensing unit
HEAT RECOVERY

Without heat recovery D With partial heat recovery (desuperheater) 10 VERSION Standard L Low noise COIL R S V 12
Aluminium Copper Tinned copper Coated

ATTENTION: Sizes up 290 to 400 are available only in the silenced mode "L". The conguration (02-04-P2-P4) option controlled by manual switch. "D" option is not compatible with "Y" valve.

11

FAN Standard M High static pressure J Inverter (ANL- 580-620-650)

119

Technical data
ANL COOLING ONLY MODEL Cooling capacity Total power input Evaporator water flow rate Total pressure drop POWER SUPPLY EER ESEER POWER SUPPLY Power supply ELECTRICAL DATA Total input current Maximum current (FLA) Starting current (LRA) Starting current with Soft Start IP PROTECTION IP GAS Type SCROLL COMPRESSOR Compressor / Circuit Crank case HYDRONIC KIT Usefoul head 01-02-P1-P2 Usefoul head 03-04-P3-P4 FAN (Axial) Fan quantity Air flow EVAPORATORS (Plates) Quantity Hydraulic connection (VICTAULIC) SOUND DATA Sound power Sound pressure W/W W/W W/W W/W V A A A A A n/n n/W kPa kPa kPa kPa n m3/h n dB(A) dB(A) dB(A) dB(A) L L /L L /L /L /L /L /L /L /L L L /L /L /L /L L L 2/1 2/44 123 162 4 15600 1 2" 73 41 2/1 2/44 114 153 4 15600 1 2" 73 41 2/1 4/44 103 179 4 15600 1 2" 74 42 38 49 130 99 24 41 53 131 101 24 2,60 3,83 2,60 3,83 2,61 3,93 2,54 3,83 2,74 2,38 4,03 3,71 2,63 2,23 3,99 3,68 2,44 2,03 3,72 3,52 kW kW kW kW l/h l/h kPa kPa L L L L 290 55 20,96 9422 28 300 60 22,99 10339 33 340 66 25,19 11388 40 400 76 29,88 13154 41 580 111 104 40,36 43,69 19205 18029 81 72 620 124 114 47,13 51,23 21472 19772 61 52 650 133 121 54,40 59,44 23013 20933 70 58

400V-3N-50Hz (with thermomagnetic switches) 46 58 162 123 24 55 69 183 140 24 R410A 2/1 4/44 93 170 6 20700 1 2" 75 43 2/1 2/75 74 91 167 183 2 35900 1 2-1/2" 82 77 50 45 2/1 2/75 80 100 174 193 2 35900 1 2-1/2" 82 77 50 45 2/1 2/75 61 87 155 180 2 35900 1 2-1/2" 83 78 51 46 70 74 85 262 198 24 82 87 99 308 230 24 94 101 112 320 242 24

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011

COOLING Evaporator water inlet 12C Evaporator water outlet 7C External air temperature 35 C

SOUND POWER: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

SOUND PRESSURE: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

120

Dimensions (mm)

ANL/L/C 290-300-340

ANL ] 290-300-340 (mm) ANL [ [ ] 290-300-340 (mm) ANL [ ] 290-300-340 (mm)

ANL/L/C 400

ANL ] 400 (mm) ANL [ [ ] 400 (mm) ANL [ ] 400 (mm)

ANL/L/C 580-620-650

ANL ] 580-620-650 (mm) ANL [ [ ] 580-620-650 (mm) ANL [ ] 580-620-650 (mm)

A A A

A A A

A A A

C C C

C C C B B B

C C C B B B B B B

DIMENSIONS/WEIGHT Height Width Depth Empty weight Functioning weight

A B C

mm mm mm Kg Kg

/L/C /L/C /L/C /L /L

ANL 290 1605 1100 2450 628 646

ANL 300 1605 1100 2450 636 654

ANL 340 1605 1100 2450 648 666

ANL 400 1605 1100 2450 666 685

ANL 580 1875 1100 3200 854 876

ANL 620 1875 1100 3200 925 949

ANL 650 1875 1100 3200 970 994

Technical data version C


Mod. ANL C Cooling capacity Total power input EER Maximum current (FLA) Starting current (LRA) Input current Sound power Sound pressure Empty weight U.M. (kW) (kW) (W/W) (A) (A) (A) dB(A) dB(A) Kg Vers. L L L All All L L L All ANL 290 55 20,7 2,66 49 130 37,7 73 41 583 ANL 300 61 22,5 2,69 53 131 40,3 73 41 591 ANL 340 67 24,8 2,69 58 162 46,2 74 42 603 ANL 400 77 29,4 2,62 69 183 54,3 75 43 616 ANL 580 115 108 39,6 39,5 2,91 2,73 85 262 69,7 73,9 82 77 50 45 799 ANL 620 128 117 46,2 47,3 2,77 2,48 99 308 81,4 87,3 82 77 50 45 848 ANL 650 138 126 53,4 54,9 2,59 2,30 112 320 94,0 100,6 83 78 51 46 893

Performance values refer to the following conditions: COOLING Evaporating temperature External air temperature t 5 C 35 C 5 C

SOUND POWER: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. SOUND PRESSURE: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744). Cod.: SANL290_650UY.03/1301

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

121

NEW

ANL 290/650
heat pump

Air cooled heat pump Axial fans Heating capacity from 61 to 142 kW Cooling capacity from 53 to 128 kW

R410A

Aermec participate in the EUROVENT program: LCP/A/P/R. the products are present on the site www.eurovent-certification.com

HEAT PUMP VERSION VERSION WITH PUMP


Features
Available in 7 sizes. Heat pump models. Monocircuit. R410A gas. Available in 2 version: [] Standard ANL 400/650 [L] Low noise vesion ANL 290/650 High efficiency scroll compressors Flow switch as standard supply.  Low and high pressure transducers as standard supply. Cooling mode: ANL-H 290-400 up to 43C Cooling mode: ANL-H 580-650 up to 44C Heating mode: ANL-H 290-650 up to 50C

VERSION WITH PUMP AND STORAGE TANK

High efficiency exchangers. Axial fans with low sound level. Versions with hydronic kit. Pump+Pump standby option controlled by manual switch. Electronic controller (Modu_control). Metallic protective cabinet with anti-corrosion polyester paint. Microprocessor control system -  Control from the entering water temperature, with the possibility of selecting control of the leaving water temperature -  Summer condensation control with 0-10V modulating signal depending on pressure,

compensated according to the outside air temperature (with DCPX accessory) - Intelligent defrosting to decay of pressure. - Automatic rotation of compressors. - Load limiting safety control. - Automatic reset of alarms before total block. - Alarm history.

Accessories
DCPX : Low temperature device for correct cooling mode operation with ambient temperatures from less than 20 C down to - 10 C. DRE: (THIS ACCESSORY MUST THEREFORE BE SPECIFIED WHEN THE ORDER IS PLACED, CAN ONLY BE APPLIED IN THE FACTORY) current reduction of about, 26% for two circuit units. Only available for three-phase models. PR3: Simplified remote panel. Permits control of the basic unit functions (on/off and change of operating mode, diagnostics and alarm reset). Maximum distance permitted is 150 m with screened cable. AERSET: accessory allows the automatic compensation of the operating setpoint of the unit to which it is connected, based on a 0-10V MODBUS input signal. Mandatory accessory: AER485 or MODU-485A MODU-485A: RS-485 interface for supervision systems with MODBUS protocol. AERWEB300: The AERWEB option allows remote control of a chiller through a standard PC and an ethernet connection with a standard browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control maximum 6 units on RS485 network; AERWEB300-18: Web server to monitor and remote control maximum 18 units on RS485 network; AERWEB300-6G: Web server to monitor and remote control maximum 6 units on RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control maximum 18 units on RS485 network with integrated GPRS modem. MULTICONTROL: Allows the simultaneous control of several chillers or heat pumps (up to 4) fitted with our MODUCONTROL controller and installed in the same hydraulic system. For complete control the following accessories are available: SPLW: System water temperature sensor. In most cases the loose supplied sensors for each chiller/heat pump are sufficient. In cases of a common flow/return header this sensor can be used to control the common system supply water temperature for the chillers connected to the header, or it can be used for temperature monitoring. VT: Anti-vibration mounts. GP: Protects the external coil from blows. RIF (THIS ACCESSORY MUST THEREFORE BE SPECIFIED WHEN THE ORDER IS PLACED, CAN ONLY BE APPLIED IN THE FACTORY): Current rephaser. Connected in parallel to the motor, it allows a reduction of the absorbed current about 10%. COMPATIBILITY WITH THE VMF SYSTEM. For further system information please refer to the specific documentation.

122

Accessory compatibility
ANL-H DCPX (version with standard fan "") DCPX (version with high static pressure fan "M") DRE PR3 AERSET MODU-485A AERWEB-300 MULTICONTROL SPLW VT (00) VT (P1-P2-P3-P4) VT (01-02-03-04) GP RIF /L /L /L /L /L /L /L /L /L /L /L /L /L /L 290 58 62 10(x2) 17 13 13 GP3 32 300 58 62 10(x2) 17 13 13 GP3 32 340 58 63 15(x2) 17 13 13 GP3 42 400 83 83 25(x2) 11 11 11 GP2 (x2) 42 580 83 83 30(x2) 11 11 11 GP2 (x2) 50 620 83 83 30(x2) 11 11 11 GP2 (x2) 72 650 83 83 30(x2) 11 11 11 GP2 (x2) 51

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most particular of system requirements. Code

1,2,3 4,5,6

DESCRIPTION ANL
SIZE

13

POWER SUPPLY

400V-3N -50 Hz 14 SOFT START Without Soft Start S With Soft Start 15-16 00 01 02 03 04 P1 P2 P3 P4 SORAGE TANK/PUMP Without pump or storage tank Low head pump and buffer tank Single and standby low head pump and buffer tank Single high head pump and buffer tank Single and standby high head pump and buffer tank Low head pump Single and standby low head pump Single high head pump Single and standby high head pump

290-300-340-400-580-620-650 7
FIELD OF USE

Standard with produced water down to +4 C Y Low leaving water up to -6 C X Electronic thermostatic valve temperature of water produced up to +4C (for different temperatures please contact us) 8 MODEL H Heat pump
HEAT RECOVERY

Without heat recovery D With partial heat recovery (desuperheater) 10 VERSION Standard L Low noise COIL R S V 12
Aluminium Copper Tinned copper Coated

ATTENTION: Sizes up 290 to 340 are available only in the silenced mode "L". The conguration (02-04-P2-P4) option controlled by manual switch. "D" option is not compatible with "Y" valve.

11

FAN Standard M High static pressure J Inverter (ANL- 400-580-620-650)

123

Technical data
ANL-H Cooling capacity Total power input Evaporator water flow rate Total pressure drop Total input current Heating capacity Total power input Condenser water flow rate Total pressure drop Total input current ENEGY INDEX EER ESEER COP POWER SUPPLY Power supply Maximum current (FLA) Starting current (LRA) IP PROTECTION IP GAS Type SCROLL COMPRESSOR (Scroll) Compressor / Circuit Crank case AXIAL FAN () Quantity Cold air flow Heat air flow EVAPORATORS (Plates) Quantity Hydraulic connection (VICTAULIC) HYDRONIC KIT Buffer tank Expansion tank Security valve SOUND DATA Sound power Sound pressure kW kW l/h kPa A kW kW l/h kPa A W/W W/W W/W V A A n/n n/W n m3/h m3/h n l n/l bar dB(A) dB(A) L L L L L /L /L /L /L /L L L /L 290 53 20,91 9152 26 37 61 18,82 10407 32 34 2,53 3,80 3,23 300 57 23,86 9888 24 41 66 20,60 11372 29 36 2,40 3,69 3,22 340 66 24,52 11348 31 45 73 22,37 12431 35 42 2,68 4,15 3,25 400 83 78 28,98 30,58 14247 13466 29 26 52 54 90 28,44 15412 33 51 2,85 2,55 4,06 3,64 3,16 580 106 101 41,54 44,60 18292 17412 44 40 68 72 122 38,73 20902 55 63 2,55 2,26 3,74 3,31 3,16 620 122 116 43,30 46,47 21088 20089 53 48 70 75 134 42,07 22834 61 68 2,82 2,50 4,06 3,60 3,17 650 128 122 48,42 51,87 22291 21150 61 55 77 83 142 46,00 24176 70 74 2,66 2,36 3,93 3,48 3,08

/L /L /L /L /L /L /L L /L /L /L /L /L /L L L

44 126 24

47 128 24

400V-3N-50Hz (with thermomagnetic switches) 54 65 98 107 160 181 264 264 24 24 R410A 24 24

116 273 24

2/1 2/44 4 17600 17000 1 2 300 1/25 6 73,4 41,7

2/1 2/44 4 17600 17000 1 2 300 1/25 6 74,1 42,4

2/1 4/44 6 17200 16400 1 2 300 1/25 6 74,3 42,6

2/1 4/44 2 45800 32060 44400 1 2 300 1/25 6 89,4 83,4 57,6 51,5

2/1 2/140 2 45800 32060 44400 1 2 400 1/25 6 89,4 84,0 57,6 52,1

2/1 2/140 2 44600 31220 43000 1 2 400 1/25 6 89,4 84,6 57,6 52,7

2/1 2/140 2 44600 31220 43000 1 2 400 1/25 6 89,4 85,2 57,6 53,4

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011

COOLING Evaporator water inlet 12C Evaporator water outlet 7C External air temperature 35 C t 5C

Heating Evaporator water inlet 40C External air temperature 7C Evaporator water outlet 45C t 5C

Sound power Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

Sound pressure Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

124

Dimensions (mm)

ANL-H 290-300

ANL ] 290-300-340 (mm) ANL [ [ ] 290-300-340 (mm) ANL [ ] 290-300-340 (mm)

ANL-H 340

ANL ] 400 (mm) ANL [ [ ] 400 (mm) ANL [ ] 400 (mm)

ANL-H 400-580-620-650

ANL ] 580-620-650 (mm) ANL [ [ ] 580-620-650 (mm) ANL [ ] 580-620-650 (mm)

A A A

A A A

A A A

C C C

C C C B B B

C C C B B B B B B

DIMENSIONS / WEIGHT Height Width Depth Empty weight "00" Functioning weight "00"

A B C

mm mm mm Kg Kg

ANL-H 290 1605 1100 2450 655 673

ANL-H 300 1605 1100 2450 660 679

ANL-H 340 1605 1100 2450 684 703

ANL-H 400 1875 1100 2950 808 832

ANL-H 580 1875 1100 3200 902 926

ANL-H 620 1875 1100 3200 1008 1033

ANL-H 650 1875 1100 3200 1053 1078

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

125

Cod.: SANLH290_650UY.00/1301

ANLI

Air cooled chiller and heat pump with axial fans Heating capacity (UNDER FLOOR HEATING) Heating capacity (FAN COILS) Cooling capacity

6.40 - 33.75 kW 6.10 - 31.70 kW 5.70 - 28.80 kW

Aermec participates at EUROVENT program: LCP/A/P/R. The involved products can be found in the website www.eurovent-certification.com

INVERTER COMPRESSOR STANDARD VERSION VERSION WITH ON/OFF PUMP OR INVERTER


Characteristics
Refrigerant R410A High efficiency at partial load Capable of variable water flow rates on primary circuit (terminals with 2-way valves) Perfect water temperature control even in systems with low water content Suitable for heat pump mode summer operation to provide domestic hot water (DHW) with the DCPX fan speed controller accessory Extended operating limits in heat pump mode ANLI 020 - 025 - 101: 1. Maximum leaving water temperature 55 C 2. Maximum external air temperature 42 C (with DCPX fan speed controller accessory) 3. Minimum external air temperature -15 C ANLI 021 - 026 - 040 - 045 - 071 - 075 - 080: 1. Maximum leaving water temperature 60 C 2. Maximum external air temperature 42 C (with DCPX fan speed controller accessory) 3. Minimum external air temperature -20 C Reduced starting currents Dual-flow electronic expansion valve with autoadaptive algorithm controlling superheat, suitable for leaving liquid temperatures: 1. down to -6 C for ANLI 020 - 025 - 101 2. down to -8 C for ANLI 021 - 026 - 040 045 - 071 - 075 - 080 High efficiency scroll and Twin rotary compressors with permanent magnet DC motors of "high side" type (with high pressure casing), designed for variable speed operation Integral pump: - ANLI: standard without pump - ANLI P: on/off pump - ANLI X: variable speed pump with water side pressure transducer installed and unit mounted microprocessor, capable of controlling various operating modes: Constant P: maintains constant pressure differential between pump inlet and outlet; pump speed reduces as terminal valves close Variable P: reduces pressure differential with flow reduction, in consideration of the pressure reduction in the pipe-work system to the terminals (recommended for larger pipe-work systems) Water filter, differential pressure switch, depending on the model, fitted on all units. Expansion tank and pressure safety valve (only units with pump) Available in heat pump version only Fitted with EMC filters Controller: - Aermec Modu_Control circuit board - User interface with 6 soft-touch keys, 4 digit display, 6 LEDs - Control of the leaving water temperature with PID algorithm - Set-point compensation based on the external air temperature - Display of operating frequency - Control of compressor ramp speed - Auto-adaptive intelligent defrosting - Condensing control in summer with a 0-10 V modulating signal based on pressure and compensated for external air temperature (with DCPX accessory - Load limiting safety control by reducing compressor speed - High and low pressure transducers - Automatic reset of alarms before tripping - Alarms history

126

Accessories
AERSET: L'accessoire AERSET permet de compenser
automatiquement (en fonction des configurations logiciel saisies) les points de consigne de travail de unit auxquels il est reli, en se basant sur un signal 0-10V MODBUS en entre; Accessoire obligatoire: AER485 ou MODU-485A BDX5: Condensate drip tray for outdoor unit. BDX8/9: Condensate drip tray with integrated electric resistance, managed by external air probe control. DCPX: Allows correct operation, in cooling mode, with outside temperatures lower than 20 C and as low as 10 C, in heating mode up to 42 C. Accessory mandatory for the production of domestic hot water (DHW) in summer mode (only for some sizes, refer to the technical manual). KR: Electric anti-freeze resistance for plate heat exchanger. Standard for sizes from 021 to 080 Can only be applied in the factory. KRB1/2/3: Electric anti-freeze resistance kit for base; prevents the formation of ice on the base. Can only be applied in the factory. PR3: Simplified remote panel. Allows to perform the basic controls of the unit with alarm signals. It can be controlled with a shielded cable at a distance up to 150 m. MODU-485A : RS-485 interface for supervising systems with MODBUS protocol. AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; MULTICONTROL: Allows the simultaneous control of several chillers or heat pumps (up to 4) fitted with our MODUCONTROL controller and installed in the same hydraulic system. For complete control the following accessories are available: SPLW: System water temperature sensor. In most cases the loose supplied sensors for each chiller/heat pump are sufficient. In cases of a common flow/return header this sensor can be used to control the common system supply water temperature for the chillers connected to the header, or it can be used for temperature monitoring. SDHW: Domestic hot water temperature sensor . Used with the storage tank to control the temperature of water produced. VT: Anti-vibration mounts. COMPATIBILITY with VMF SYSTEM For further information on system, refer to specific documentation.

Available accessories ANLI


AERSET

Available accessories 20 51 9 5 2 25 51 9 5 2 101 53 15 2 ANLI


AERSET

vers. () / P / X

vers. () / P / X

21 51 9 8 -

26 51 9 8 -

40 51 9 9 -

45 51 9 9 -

71 51 9 9

75 51 9 9

80 51 9 9

PR3 MODU-485A AERWEB300 MULTICONTROL SPLW SDHW DCPX VT BDX KR (1) BSK4KW230M BSK6KW230M BSK6KW400T BSK9KW400T KRB3 (1) 1 Factory fitted only.

PR3 MODU-485A AERWEB300 MULTICONTROL SPLW SDHW DCPX VT BDX (1) KRB1 (1) KRB2 (1) BSK4KW230M BSK6KW230M BSK6KW400T BSK9KW400T

() / P / X () / P / X 230V/1 230V/1 400V/3N 400V/3N () / P / X

() / P / X () / P / X () / P / X 230V/1 230V/1 400V/3N 400V/3N

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system requirements.

Configuration fields:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 | | | | | | | | | Code | Model | Heat recovery | Field of use | Power supply | | | | Size Version Coil Evaporator Code: ANLI Size: 020 - 025 - 101 021 - 026 - 040 - 045 - 071 - 075 - 080 Model: H - Heat Pump Version: - Standard (without pump) P - With ON/OFF pump X - With INVERTER pump Heat recovery: - Without heat recovery Coil: - Aluminium R - Copper S - Tinned copper V - Coated aluminium Field of use: - Standard for leaving liquid temperature down to -6 C for sizes 020 - 025 - 101 - Standard for leaving liquid temperature down to -8 C for sizes 021 - 026 - 040 - 045 - 071 - 075 - 080 Evaporator: - Standard PED regulations Power supply: M - 230V/1/50Hz sizes 020 - 025 | 021- 026 - 040 - 045 T - 400V/3N/50Hz sizes 101 | 071 - 075 - 080

Example of a configuration code: ANLI101HT This is an ANLI unit, size 101, heat pump model, standard (without pump), without heat recovery, aluminium condenser coil, standard field of use, standard evaporator, and electrical panel for compressors with 400V/3N/50Hz motors.

127

Technical Data
ANLI Heating mode: water 40/45 C - air 7 C db / 6 C wb (fan coils) H kW Heating capacity HP|HX kW H kW Input power HP|HX kW H A Total input current HP|HX A H W/W COP HP|HX W/W H l/h Water flow rate HP|HX l/h Pressure drops H kPa Heating mode: water 30/35C - air 7C d.b./6C w.b. (floor heating) H kW Heating capacity HP|HX H kW Input power HP|HX kW H A Total input current HP|HX A H W/W COP HP|HX W/W H l/h Water flow rate HP|HX l/h Pressure drops H kPa Cooling mode water 12/7C - external air 35C H kW Cooling capacity HP|HX H kW Input power HP|HX kW H A Total input current HP|HX A H W/W EER HP|HX W/W H ESEER HP HX H l/h Water flow rate HP|HX l/h Pressure drops H kPa Available head HP|HX kPa COMMON DATA FOR ALL VERSIONS Electrical data H A Maximum current (FLA) HP|HX A H A Starting current (LRA) HP|HX A Protection rating Compressor Quantity/circuit n Partializations % System side heat exchanger Quantity n Hydraulic connections Fans Quantity n Air flow rate in cooling mode m3/h Sound data Sound pressure dB(A) Sound power dB(A)
DATA DECLARED IN ACCORDANCE WITH THE STANDARD UNI EN 14511-2 2011 SINCE FOR THE ANLI 101 MODEL THE COMPRESSOR CONTROL RANGE IS WIDER THAN PREVIOUS MODELS, THE FOLLOWING DATA IS PROVIDED IN THE DECLARATION OF PERFORMANCE: FREQUENCY F1 MAXIMUM PERFORMANCE FREQUENCY F2 PERFORMANCE COMPLIANT WITH FRENCH STANDARD NF 414 FREQUENCY F3 INTERMEDIATE PERFORMANCE Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

020H 6.18 6.1 2.08 2.1 10.1 10.6|10.6 2.97 2.90 1063 1049 25 6.48 6.40 1.72 1.74 8.4 8.9|8.9 3.77 3.68 1114 1100 28 5.88 5.95 2.12 2.14 10.3 10.8|10.8 2.77 2.78 3.58 3.36 3.65 1011 1023 23 57-57
230V/1/50Hz

025H F1 7.31 7.21 2.33 2.35 11.3 11.8 3.14 3.07 1257 1241 29 7.66 7.59 1.93 1.94 9.4 9.9 3.97 3.91 1318 1306 32 6.42 6.5 2.42 2.44 10.9 11.4 2.65 2.66 3.54 3.60 3.91 1104 1117 29 52-52 14.0 14.5 20.0 20.5 1|1 1 1"1/4 1 3500 37.0 68.0 31.7 31.0 11.4 11.45 15.7 17.1 2.78 2.71 5452 5332 59 33.75 33.01 9.85 9.86 13.4 14.8 3.43 3.35 5805 5678 66 28.77 29.43 11.73 11.82 16.3 17.7 2.45 2.49 4.11 4.40 4.40 4948 5061 50

101H F2 24.95 24.3 8.34 8.35 11.5 12.9 2.99 2.91 4291 4179 36 25.34 24.65 7.05 7.06 9.6 11 3.59 3.49 4359 4239 37 23.95 24.53 8.14 8.31 11.3 12.7 2.94 2.95 4.11 4.40 4.40 4120 4219 30 92
400V/3N/50Hz

F3 20.08 19.54 6.36 6.38 8.8 10.2 3.16 3.06 3454 3362 23 20.87 20.32 5.44 5.46 7.4 8.8 3.84 3.72 3590 3494 28 20.03 20.23 6 5.8 8.3 9.7 3.34 3.49 4.11 4.40 4.40 3445 3480 24

14.0 14.5-14.5 20.0 20.5-20.5 1|1 1 1"1/4 1 2500 29.0 61.0

21.0 22.4 30.0 31.4-30.7 IP24 SCROLL 1|1 35-100 PLATES 1 1"1/4 AXIAL

21.0 22.4 30.0 31.4-30.7 1|1 1 1"1/4 2 13200 44.0 76.0

21.0 22.4 30.0 31.4-30.7 1|1 1 1"1/4

Dimensional data (mm)


310 900 384 1124 1800 1750

354

020H - 025H ANLI Empty weight

1750

1450

1252

868 428

101H 020H 025H 101H 70 70 293 72 72 308

750

128

H HP|HX

kg kg

Technical data
ANLI 021H Heating mode: water 40/45C - air 7C d.b./6C w.b. (fan coils) H kW 6,23 Heating capacity HP kW 6,18 HX kW 6,14 H kW 1,93 Input power HP kW 1,97 HX kW 1,90 H W/W 3,23 COP HP W/W 3,14 HX W/W 3,23 Water flow rate ALL l/h 1066 Pressure drop H kPa 11 Heating mode: water 30/35C - air 7C d.b./6C w.b. (floor heating) H kW 6,58 Heating capacity HP kW 6,52 HX kW 6,48 H kW 1,63 Input power HP kW 1,66 HX kW 1,59 H A 6,7 Total input current HP A 7,5 HX A 7,2 H W/W 3,23 COP HP W/W 3,14 HX W/W 3,23 Water flow rate ALL l/h 1125 Pressure drop H kPa 13 HP kPa 64 Available head HX kPa 72 Cooling mode water 12/7C - external air 35C H kW 5,71 Cooling capacity HP kW 5,75 HX kW 5,79 H kW 1,94 Input power HP kW 1,98 HX kW 1,91 H A 8,4 Total input current HP A 9,2 HX A 8,9 H W/W 2,95 EER HP W/W 2,91 HX W/W 3,03 H 4,15 ESEER HP 4,11 HX 4,38 Water flow rate ALL l/h 987 Pressure drop H kPa 11 COMMON DATA FOR ALL VERSIONS Electrical data Maximum current (FLA) H A 12.1 Starting current (LRA) H A 8.0 Protection rating Compressor Quantity/circuit n 1/1 Partializations % 33-100 System side heat exchanger Quantity n 1 Hydraulic connections 1"1/4 Fans Quantity 1 Air flow rate in cooling mode m3/h 3500 Sound data Sound pressure dB(A) 31 Sound power dB(A) 62 026H 7,79 7,72 7,68 2,45 2,46 2,40 3,18 3,13 3,20 1331 18 8,16 8,08 8,03 2,07 2,07 2,00 8,6 9,4 9,1 3,18 3,13 3,20 1393 20 56 65 7,26 7,33 7,37 2,58 2,59 2,53 11,2 12,0 11,7 2,82 2,83 2,92 4,10 4,29 4,54 1256 17 14.1 8.0 1/1 27-100 1 1"1/4 1 3500 32.5 63.5 040H 9,92 9,82 9,78 3,17 3,16 3,09 3,13 3,11 3,16 1698 12 10,51 10,41 10,37 2,68 2,67 2,60 11,4 12,2 11,9 3,13 3,11 3,16 1799 14 59 70 9,39 9,48 9,52 3,17 3,17 3,10 13,7 14,5 14,2 2,97 2,99 3,07 4,06 4,22 4,36 1622 12 20.0 10.0 1/1 37-100 1 1"1/4 2 8000 35.7 66.7 045H 12,75 12,62 12,57 4,23 4,19 4,12 3,02 3,01 3,05 2179 20 12,94 12,81 12,76 3,55 3,51 3,44 15,1 15,9 15,6 3,02 3,01 3,05 2212 20 50 60 12,25 12,37 12,42 4,37 4,34 4,27 19,1 19,9 19,6 2,80 2,85 2,91 4,10 4,40 4,47 2119 20 23.6 10.0 IP24 1/1 30-100 PLATES 1 1"1/4 AXIAL 2 8000 36.7 67.7 071H 15,16 14,99 14,94 4,85 4,82 4,70 3,13 3,11 3,18 2594 18 16,17 15,98 15,95 4,08 4,04 3,92 6,1 7,7 6,8 3,13 3,11 3,18 2766 21 85 67 13,66 13,82 13,88 4,80 4,79 4,66 7,3 8,9 8,0 2,84 2,89 2,98 4,20 4,19 4,65 2363 18 12.5 15.0 1/1 34-100 1 1"1/4 2 7500 36.7 67.7 075H 17,60 17,39 17,38 6,07 6,01 5,92 2,90 2,89 2,94 3008 24 18,57 18,35 18,35 5,09 5,02 4,94 7,6 9,2 8,3 2,90 2,89 2,94 3173 28 76 46 16,35 16,55 16,58 6,16 6,11 6,00 9,4 11,0 10,1 2,66 2,71 2,76 4,17 4,33 4,65 2831 25
400V/3N/50Hz

080H 20,12 19,89 19,91 7,27 7,19 7,13 2,77 2,77 2,79 3437 32 21,03 20,78 20,82 6,13 6,03 5,99 9,0 10,7 9,7 2,77 2,77 2,79 3590 35 66 25 18,51 18,73 18,73 7,63 7,55 7,47 11,4 13,1 12,2 2,43 2,48 2,51 4,12 4,34 4,59 3207 32 15.0 15.0 1/1 25-100 1 1"1/4 2 7500 38 69 Code: SANLIUY.10 / 1212

230V/1/50Hz

13.5 15.0 1/1 28-100 1 1"1/4 2 7500 38 69

Dimensional data (mm)


ANLI Height Width Depth Empty weight H HP|HX mm mm mm kg kg all all all 021H 026H 040H 045H 071H 1028 1028 1281 1281 1281 1000 1000 1000 1000 1150 400 400 450 450 450 118 118 138 138 174 123 123 143 143 184 075H 1281 1150 450 174 184 080H 1281 1150 450 174 184

021H - 026H

040H - 045H

071H - 075H - 080H


Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

129

ANK
R410A
Aermec participates in the EUROVENT programme: LCP/A/P/R. The products involved can be found at the website www.eurovent-certification.com

Air cooled heat pump with axial fans Heating capacity from 7,98 to 33,51 kW Cooling capacity from 6,82 to 29,92 kW

PRODUCTION OF HOT WATER UP TO 60 C OPTIMISED FOR HEAT PUMP OPERATION HIGH EFFICIENCY COMPRESSORS HEATING OPERATION WITH EXTERNAL TEMPERATURES DOWN TO -20 C PRODUCTION OF HOT DOMESTIC WATER WITH EXTERNAL TEMPERATURES FROM -20 C UP TO 42 C AVAILABLE OPTIONS: - WITH PUMP - WITH PUMP AND BUFFER TANK
Characteristics
Available in 8 sizes 3 versions available: ANK H: Standard ANK HP: With pump ANK HA: With pump and buffer tank High-efficiency scroll compressor with crank case heater High efficiency heat exchangers with trace heating as standard Flow switch fitted as standard Electronic controller with start timers and control of defrost cycles Axial flow fans for quiet operation Metal enclosure with anti-corrosion polyester paint Electronic soft start to reduce starting current (standard for single phase versions)

Accessories
VT ANTI-VIBRATION MOUNTS: Set of antivibration mounts. MODU-485A: RS-485 interface for supervising systems with MODBUS protocol. AERSET The AERSET accessory allows the automatic compensation of the operating setpoint of the unit to which it is connected, based on a 0-10V MODBUS input signal. Mandatory accessory: AER485 or MODU-485A AERWEB300: The AERWEB option allows remote control of a chiller through a standard PC and an ethernet connection with a standard browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control maximum 6 units on RS485 network; AERWEB300-18: Web server to monitor and remote control maximum 18 units on RS485 network; AERWEB300-6G: Web server to monitor and remote control maximum 6 units on RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control maximum 18 units on RS485 network with integrated GPRS modem. MULTICONTROL: Allows the simultaneous control of several chillers or heat pumps (up to 4) fitted with our MODUCONTROL controller and installed in the same hydraulic system. For complete control the following accessories are available: SPLW: System water temperature sensor. In most cases the loose supplied sensors for each chiller/ heat pump are sufficient. In cases of a common flow/return header this sensor can be used to control the common system supply water temperature for the chillers connected to the header, or it can be used for temperature monitoring. SDHW: Domestic hot water temperature sensor. Used with the storage tank to control the temperature of water produced. DCPX: Fan speed controller allowing operation in cooling mode within an external temperature range from +20 C to -10 C; in heating mode in summer to produce DHW with external temperatures up to +42 C. DRE: Electronic soft starter. Reduces starting current by about 30%. KRB: Electric anti-freeze heater for the base. Prevents the formation of ice on the base. BSKW: Electric heater kit with IP44 panel for remote mounting in a sheltered area. Available in single and three phase power supply: - BS4KW230M (4 kW, 230V/1/50Hz) - BS6KW230M (6 kW, 230V/1/50Hz) - BS6KW400T (6 kW, 400V/3/50Hz) - BS9KW400T (9 kW, 400V/3/50Hz) BDX: Condensate drip tray with integrated electric heater controlled by the external air temperature sensor. PR3: Simplified remote panel. Permits control of the basic unit functions (on/off and change of operating mode, diagnostics and alarm reset). Maximum distance permitted is 150 m with a 7 core screened cable, minimum size 0.5 mm. Compatibility with the VMF system For further system information please refer to the specific documentation.

130

ANK VT BDX

Vers. H-HP HA

020 030 040 045 050 085 VT9 VT9 VT9 VT9 VT9 VT9 VT15A VT15A VT15A VT15A VT15A VT15A BDX8 BDX9 BDX9 BDX9 BDX9 BDX9

100 VT15 VT15 -

150 VT15 VT15 -

ELECTRICAL ACCESSORIES DRE5 1 DCPX51 2 DCPX53 2 MODU-485A 2 AERSET AERWEB300 VMF-CRP VMF-VOC VMF-E5B o N 2 VMF-ACS3KM 2 230V-1 VMF-ACS3KTN 2 400V-3N VMF-ACS6KTN 2 400V-3N VMF-ACS8KTN 2 400V-3N KRB1 KRB2 KRB3 PR3 BS4KW230M BS6KW230M BS6KW400T BS9KW400T

(x2)

(x2) NOTE: 1. Only available for 400V/3N/50Hz units. Factory fitted only. 2. MODU-485A |DCPX |VMF-ACS |VMF E5 accessories are mandatory for the control and production of DHW. Accessories DRE/KRB1/KRB2/KRB3 and BDX8/9 factory fitted only.

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most particular of system requirements.

Configuration fields:
1 2 3 4 5 6 7 8 9 10 11 12 13 | | | | | | | | | Code | Model | Execution | Field of use | Power supply | | | | Size Version Coil Evaporator Code: Coil: ANK - Aluminium R - Copper Size: S - Tinned copper 020, 030, 040, 045, 050, 085, 100, 150 V - Epoxy coated aluminium Model: H - Heat pump Version: - Standard P - With pump A - With pump and buffer tank Execution: - Standard Field of use: - Leaving water temperature down to +4 C Z - Leaving liquid temperature from +4 C down to 0 C Y - Leaving liquid temperature from 0 C down to -8 C Evaporator: - Standard Power supply: - 400V/3N/50Hz M - 230V/1/50Hz for sizes 020 - 030 - 040 - 045

Attention: - the standard options are shown by the symbol Example of the configuration code: ANK085HPR This is an ANK unit, size 085, heat pump model, with pump, standard execution, copper condenser coil, standard evaporator, and electrical panel 400V/3N/50Hz.

131

EUROVENT Technical Data


ANK Heating capacity H HP-HA H HP-HA H HP-HA H HP-HA H HP-HA H HP-HA H HP-HA H HP-HA H HP-HA H HP-HA H HP-HA H HP-HA H HP-HA H H Vers. 230V/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N kW kW kW kW kW kW kW kW A A A A W/W W/W W/W W/W l/h l/h l/h l/h kPa kPa kPa kPa kW kW kW kW kW kW kW kW A A A A W/W W/W W/W W/W 020 7,98 7,98 7,87 7,87 2,54 2,5 2,59 2,55 12,29 4,71 13,32 5,6 3,14 3,19 3,04 3,09 1373 1373 1354 1354 24 24 62 62 6,82 6,76 6,91 6,84 2,36 2,33 2,43 2,41 11,31 4,38 12,43 5,31 2,89 2,9 2,84 2,84 3,16 3,18 3,28 3,3 1173 1163 1189 1176 16 16 65 65 13,90 6,10 45,00 39,70 1/1 0-100 030 10,05 10,05 9,91 9,91 3,11 3,11 3,15 3,15 14,55 6,21 15,55 7,1 3,23 3,23 3,15 3,15 1729 1729 1705 1705 16 15 67 67 8,15 8,15 8,25 8,25 2,82 2,82 2,89 2,89 13,15 5,67 14,27 6,6 2,89 2,89 2,85 2,85 3,24 3,24 3,37 3,35 1402 1402 1419 1419 9 9 70 70 19,40 7,70 45,00 40,30 1/1 0-100 040 10,88 12,26 10,74 12,1 3,47 3,79 3,51 3,81 17,12 7,66 18,13 8,52 3,14 3,23 3,06 3,18 1871 2109 1847 2081 19 23 62 57 9,55 10,48 9,67 10,61 3,24 3,55 3,3 3,61 15,84 7,12 16,94 8,05 2,95 2,95 2,93 2,94 3,28 3,27 3,45 3,44 1643 1803 1663 1825 14 16 64 61 22,20 9,10 45,00 54,30 1/1 0-100 045 13,5 14,07 13,29 13,85 3,88 4,18 3,98 4,27 19,18 8,06 21,03 9,6 3,48 3,37 3,34 3,24 2322 2420 2286 2392 19 21 82 79 11,69 11,57 11,85 11,74 3,73 3,98 3,88 4,12 18,58 7,71 20,66 9,31 3,13 2,91 3,05 2,85 3,46 3,25 3,47 3,26 2011 1990 2038 2019 14 14 87 87 25,00 10,60 45,00 61,30 1/1 0-100 050 15,38 15,15 4,44 4,54 9 10,6 3,46 3,34 2645 2606 25 72 13,04 13,22 4,34 4,49 8,75 10,41 3 2,94 3,4 3,45 2243 2274 18 80 11,80 71,30 1/1 0-100 085 17,49 17,25 5,07 5,13 10,43 12,03 3,45 3,34 3008 2967 30 65 15,48 15,68 5,22 5,35 10,71 12,38 2,97 2,93 3,33 3,41 2663 2697 24 70 12,30 91,30 1/1 0-100 100 27,19 26,59 8,43 8,37 17,6 18,61 3,23 3,18 4677 4573 37 113 25,20 25,78 8,18 8,13 17,05 18,08 3,08 3,17 3,89 4,08 4334 4434 32 113 21,70 72,60 2/1 0-50-100 150 33,51 32,72 10,56 10,61 21,33 23,21 3,17 3,08 5764 5628 47 127 29,20 29,92 10,13 10,2 20,4 22,25 2,88 2,93 3,85 3,93 5022 5146 36 140 25,80 104,70 2/1 0-50-100

Total input power

Total input current

COP

Water flow rate Pressure drop Available head Cooling capacity

Total input power

Total input current

EER

ESEER

Water flow rate Pressure drop Available head Maximum current (FLA) Starting current (LRA) 3

COMPRESSOR SCROLL Quantity/circuit all Part load Refrigerant SYSTEM SIDE HEAT EXCHANGER Quantity all Hydraulic connections all FANS AXIAL Quantity all Air flow rate all Sound pressure all Sound power all Data declared in accordance with UNI EN 14511:2011

l/h l/h l/h l/h kPa kPa kPa kPa A A A A n/n %

R410A

N n m3/h dB(A)

1 1" 1/4 1 3500 37,0 68,0

1 1" 1/4 2 8000 39,5 70,5

1 1" 1/4 2 8000 39,5 70,5

1 1" 1/4 2 7500 39,5 70,5

1 1" 1/4 2 7500 39,5 70,5

1 1" 1/4 2 7500 39,5 70,5

1 1" 1/4 2 14500 45,5 77

1 1" 1/4 2 13500 46,5 78

HEATING: Entering condenser water temperature 40 C Leaving condenser water temperature 45 C External air temperature 7 C db / 6 C wb COOLING: Entering evaporator water temperature Leaving evaporator water temperature External air temperature

Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

NOTE: 3 Single phase units have soft start fitted as standard.

12 C 7 C 35 C

132

MCS Technical Data 230V/1/50Hz


A 7/W 35 Heating capacity Total input power COP Vers. ANK020 H 8,363 HP-HA 8,256 kW H 2,039 HP-HA 2,124 H 4,10 W/W HP-HA 3,88 ANK030 10,700 10,620 2,664 2,668 4,01 3,98 ANK040 11,694 11,658 2,914 2,929 4,01 3,98 ANK045 14,040 13,840 3,270 3,375 4,294 4,10 Data declared in accordance with UNI EN 14511: 2008
NOTE: A External air temperature W Leaving condenser water temperature

EHPA Technical Data 400V/3N/50Hz


A 2/W 35 Heating capacity Total input power COP Vers. ANK020 H 6,260 HP-HA 6,048 kW H 1,870 HP-HA 1,940 H 3,34 W/W HP-HA 3,11 All l/h H kPa HP-HA All m3/h All dB(A) All ANK020 1470 28 55.0 3500 37.0 68.0 ANK030 8,179 8,045 2,545 2,583 3,21 3,11 ANK030 1840 16 63.0 8000 39.5 70.5 ANK040 9,764 9,610 3,074 3,097 3,17 3,10 ANK040 2260 24 51.0 8000 39.5 70.5 ANK045 11,239 11,021 3,378 3,467 3,32 3,17 ANK045 2550 18 74 7500 39.5 70.5 ANK050 11,556 11,330 3,550 3,649 3,25 3,10 ANK050 2800 22 66 7500 39.5 70.5 ANK085 13,300 12,568 4,110 4,045 3,23 3,10 ANK085 3222 27 56 7500 39.5 70.5 Data declared in accordance with UNI EN 14511: 2008
NOTE: A External air temperature W Leaving condenser water temperature 4 Water flow rates refer to conditions: Entering condenser water temperature. 30 C Leaving condenser water temperature. 35 C External air temperature 7 C db / 6 C wb

Water flow rate 4 Pressure drop Available head Air flow rate Sound pressure Sound power

Technical Data
ANK Heating capacity Vers. 230V/1 H 400V/3N 230V/1 HP-HA 400V/3N 230V/1 H 400V/3N 230V/1 HP-HA 400V/3N 230V/1 H 400V/3N 230V/1 HP-HA 400V/3N 230V/1 H 400V/3N 230V/1 HP-HA 400V/3N 230V/1 H 400V/3N 230V/1 HP-HA 400V/3N 230V/1 H 400V/3N 230V/1 HP-HA 400V/3N kW kW kW kW kW kW kW kW W/W W/W W/W W/W kW kW kW kW kW kW kW kW W/W W/W W/W W/W 020 8,67 8,67 8,58 8,58 2,12 2,12 2,21 2,18 4,10 4,10 3,89 3,94 9,44 9,36 9,57 9,53 2,48 2,45 2,51 2,48 3,81 3,82 3,81 3,82 030 10,92 10,92 10,84 10,84 2,64 2,64 2,64 2,64 4,14 4,14 4,10 4,10 11,30 11,30 11,43 11,49 2,95 2,95 3,00 3,00 3,83 3,82 3,81 3,81 040 11,93 13,40 11,90 13,24 2,88 3,22 2,90 3,23 4,14 4,17 4,10 4,10 13,23 14,52 13,38 14,77 3,40 3,73 3,43 3,76 3,89 3,89 3,90 3,90 045 14,04 14,80 13,84 14,88 3,27 3,55 3,37 3,60 4,29 4,17 4,11 4,13 16,30 16,04 16,54 16,27 3,93 4,18 4,08 4,27 4,15 3,84 4,05 3,81 050 16,27 16,12 3,81 3,91 4,27 4,12 18,07 18,33 4,56 4,66 3,96 3,93 085 18,46 18,31 4,36 4,45 4,23 4,11 21,43 21,74 5,50 5,59 3,89 3,88 100 29,12 28,49 7,03 6,95 4,14 4,10 33,69 34,41 8,88 8,74 3,80 3,94 150 35,90 35,06 8,92 8,94 4,03 3,92 39,06 39,96 11,02 11,03 3,55 3,62 Data declared in accordance with UNI EN 14511:2011 HEATING: Entering condenser water temperature 30 C Leaving condenser water temperature 35 C External air temperature 7 C db / 6 C wb COOLING: Entering evaporator water temperature 23 C Leaving evaporator water temperature 18 C External air temperature 35 C

Total input power

COP

Cooling capacity

Total input power

EER

Dimensions (mm)
ANK Height (A) Width (B) Depth (C) Weight empty Vers. H-HP HA H HP HA mm mm mm mm kg kg kg 020 1028 1000 1358 400 118 123 160 030 1281 1000 1450 450 149 154 211 040 1281 1000 1450 450 152 157 214 045 1281 1000 1450 450 165 175 232 050 1281 1000 1450 450 172 182 238 085 1281 1000 1450 450 174 184 241 100 1450 1750 750 296 314 364 150 1450 1750 750 341 362 412

B
A A

vers. H-HP

vers. HA

ANK 100 - 150 H-HP-HA


Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

133

Cod.: SANKUY.07 / 1302

HBI

R410A

Air cooled split system heat pump for heating, cooling and production of DHW DC Inverter Technology Heat capacity from 6.2kW to 16kW
HBI_C HBI_E HBI_WT / WTS

AERMEC partecipates in the EUROVENT programme for: LCP/A/S/R The products of interest can be found on the website www.eurovent-certification.com

Unit mounted control panel (HBI_E)

Characteristics
6 sizes single phase HBI_C outdoor unit and 3 sizes three phase HBI_CT outdoor unit available 6 sizes single phase HBI_E outdoor unit (Hydronic module) and 3 sizes three phase HBI_ET outdoor unit available for wall installation, with compact dimensions 4 sizes of DHW Storage Tank available of 200 300 litres capacity with main coil, electric heater and supplementary heating coil Refrigerant R410A Outdoor unit with one or two fans with DC Inverter motor for continuous speed modulation The DC Inverter compressors have been selected to maximise efficiency, reduce consumption and minimise starting current Microprocessor controller Operating modes: -Cooling -Heating -Domestic Hot Water production Possibility of prioritising operating mode Very quiet operation Anti-legionella Cycle: function can be set via the Control Panel on the HBI_E indoor unit Anti-freeze function for the Hydronic Module and DHW Storage Tank Indoor unit fitted (hydraulic side) with: -water filter -plate heat exchanger -expansion vessel (10 litres) -electric heaters: 1step (6 kW) for three phase unit 2 steps (1.5 kW+1.5 kW) only HBI060E unit 2 steps (3 kW+3 kW) single phase activated/ deactivated -air vent -safety valve (3 bar) -flow switch -circulation pump -gauge Maximum length of the refrigerant pipes up to 30 m, maximum level difference between outdoor unit and indoor unit 15 m Outdoor unit supplied with Base Electric Heating Kit to prevent the formation of ice during heat pump operating mode Indoor unit capable of controlling: - 2-way valve - 3-way valve - Remote contact - Ambient Thermostat - Ambient Temperature Sensor (supplied loose), can be installed in the wall in a rectangular 3-module recess box (type 503) Weekly Timer Auto-Restart Function Operational limits: -Cooling Outdoor air temperature +10 C to +48 C -Heating Outdoor air temperature -20 C to +35 C -Domestic Hot Water production Outdoor air temperature -20 C to +45 C Emergency Operation: in the event of malfunction of the outdoor unit operating Heating or DHW mode, the electric heaters are activated Condensing control device as standard; permits cooling mode operation with outdoor temperatures down to +10 C

Accessories
HBI_WT (230V ~ 50Hz) HBI_WTT (400V 3N ~ 50Hz) 200, 300 litre DHW Storage Tank with main coil and 3 kW electric supplementary heater -Magnesium sacrificial anode -Stainless steel tank and coil -External covering in painted sheet steel and heat insulating material, thickness 50 mm -Indoor installation HBI_WTS (230V 3N ~ 50Hz) HBI_WTST (400V 3N ~ 50Hz) 200, 300 litre DHW Storage Tank with main coil, supplementary heating coil and 3 kW electric supplementary heater -Magnesium sacrificial anode -Stainless steel tank and coil -External covering in painted sheet steel and heat insulating material, thickness 50 mm -Indoor installation

134

HBI_WT/WTS Accessory Compatibility (DHW Storage Tank)


MODEL 230V~50Hz HBI200WT/WTS HBI300WT/WTS MODEL 400V 3N~50Hz HBI200WTT/WTST HBI300WTT/WTST HBI060 3 3 HBI080 3 3 HBI100 3 3 HBI120 3 3 HBI120 3 3 HBI140 3 3 HBI140 3 3 HBI160 3 3 HBI160 3 3

Technical Data
Cooling capacity (1) (nominal) Input power (1) (nominal) EER (1) Cooling capacity (2) (nominal) Input power (2) (nominal) EER (2) Heating capacity (1) (nominal) Input power (1) (nominal) COP (1) Heating capacity (2) (nominal) Input power (2) (nominal) COP (2) Max input power (without electric heater) Cooling Max input power (without electric heater) Heating OUTDOOR UNIT
Electric power supply Air flow rate

kW kW kW kW kW kW kW kW kW kW

HBI060C HBI080C HBI100C HBI120C HBI140C HBI160C HBI120CT HBI140CT HBI160CT 5.5 9.05 10.5 14 15 15.5 14 15 15.5 1.62 2.50 3.14 3.68 4.29 4.63 3.68 4.29 4.43 3.4 3.62 3.34 3.8 3.5 3.35 3.8 3.5 3.5 4 6.5 8.0 10 11 11.5 10 10.5 11 1.54 2.50 3.08 3.45 3.93 4.6 3.45 3.75 4.07 2.6 2.6 2.6 2.9 2.80 2.5 2.9 2.8 2.7 6.2 8.5 10 12 13.5 16 12 14 15 1.51 2.10 2.50 2.79 3.21 3.95 2.67 3.33 3.7 4.1 4.00 4.00 4.3 4.2 4.00 4.5 4.2 4.05 5.5 8.0 9.0 11.5 12.5 14 11 12 14 1.83 2.54 2.90 3.38 3.73 4.59 3.23 3.58 4.38 3 3.15 3.1 3.4 3.35 3.05 3.4 3.35 3.2 2.46 2.75
230V~50Hz

5 4.6
230V~50Hz

5 4.6
230V~50Hz

6.6 5.5
230V~50Hz

6.6 5.5
230V~50Hz

7 6

7.0 6.0

7.0 6.0

7.5 6.5

m/h / / / 6398 6398 6398 3766 3766 3766 N of fans n / 1 1 2 2 2 2 2 2 R410A refrigerant charge kg 1.7 2 2 3.3 3.3 3.3 3.5 3.5 3.5 e Sound pressure dB(A) 57 57 57 57 57 60 57 57 60 e Sound pressure dB(A) 59 59 59 59 59 62 59 59 62 Liquid 6.35(1/4) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) 9.52(3/8) Cooling connections Gas 12.7(1/2) 15.9(5/8) 15.9(5/8) 15.9(5/8) 15.9(5/8) 15.9(5/8) 15.9(5/8) 15.9(5/8) 15.9(5/8) flare Type INDOOR UNIT HBI060E HBI080E HBI100E HBI120E HBI140E HBI160E HBI120ET HBI140ET HBI160ET (3) Input power indoor unit W 200 245 245 245 245 245 200 200 200 Pump max input power W 200 205 205 205 205 205 200 200 200 Speeds n 3 3 3 3 3 3 3 3 3 Electric heater capacity power (4) kW 1.5+1.5 3+3 3+3 3+3 3+3 3+3 6 6 6 Hydraulic connections (In/Out) - (Male) G1" G1" G1" G1" G1" G1" G1" G1" G1" Expansion vessel capacity l 10
Electric power supply Outlet water temperature Outlet water temperature Outlet water temperature Outlet water temperature e eSound pressure Cooling connections

230V~50Hz 400V 3N~50Hz 400V 3N~50Hz 400V 3N~50Hz

(range) (range) (1) (range) (2) (range)


(1) (2)

C 18 25 C 7 25 C 25 45 C 25 55 dB(A) 31 Liquid 6.35(1/4) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8) Gas 12.7(1/2) 15,9(5/8) 15,9(5/8) 15,9(5/8) 15,9(5/8) 15,9(5/8) 15,9(5/8) 15,9(5/8) 15,9(5/8) flare Type

230V~50Hz

230V~50Hz

230V~50Hz

230V~50Hz

230V~50Hz

230V~50Hz 400V 3N~50Hz 400V 3N~50Hz 400V 3N~50Hz

HBI_WT/WTS Accessory Technical Data


Domestic Hot Water storage tank Capacity DHW outlet temperature

Electric heater capacity Electric heater input current Electric power supply Utility hydraulic connections (In/Out) - (Female) Main coil hydraulic connections (In/Out) - (Female) Supplementary coil hydraulic connections (In/Out) - (Female) Supplementary coil Data in accordance with UNI EN 14511-2011

l C kW A m mm

HBI200WT/WTT HBI200WTS/WTST HBI300WT/WTT 200 200 300 40 80 (5) 3 3 3 13 13 13


230V~50Hz 400V 3N~50Hz

HBI300WTS/WTST 300 3 13

L xs

G1/2 G3/4 -

230V~50Hz 400V 3N~50Hz

G1/2 G3/4 G3/4 10 22 x 0,8

230V~50Hz 400V 3N~50Hz

G1/2 G3/4 -

230V~50Hz 400V 3N~50Hz

G1/2 G3/4 G3/4 10 22 x 0,8

DHW outlet temperature Pump max power input + Auxiliaries Electric heater 2 step ON/OFF control from Control Pane (5) With electric heater/without electric heaters 40 50C
(3) (4) (1) Under

floor system 23C / 18C 35C B.S. / 24CB.U.

(2) Fan

coil units 12C / 7C 35C B.S. / 24C B.U.

Cooling - Inlet/outlet water temperature - External air temperature


(1) Under

Cooling - Inlet/outlet water temperature - External air temperature


(2) Fan

floor system

coil units 40C / 45C 7C B.S. / 6C B.U.

Heating (without electric heaters): - Inlet/outlet water temperature 30C / 35C - External air temperature 7C B.S. / 6C B.U. measured at 1m in a semi anechoic chamber measured at 1.4m in a semi-anechoic chamber

Heating (without electric heaters): - Inlet/outlet water temperature - External air temperature

135

HBI System Configuration

OUTDOOR UNIT

INDOOR UNIT

Under floor system

2-way valve

3-way valve

Supplementary heat sources

Fan coils

Storage tank HBI_WT / WTS

The supplementary coil is present only in HBI_WTS models

Supply The main coil is present in all HBI_WT / WTS modelS

Fan coils

Water inlet

System example - operating in heating mode

Fill point

Tank drain

136

Dimensional Data

C A

A B C
Indoor unit MODEL HBI060E HBI080E HBI100E HBI120E HBI140E HBI160E HBI120ET HBI140ET HBI160ET Height(A) (mm) 900 900 900 900 900 900 900 900 900 Width(B) (mm) 500 500 500 500 500 500 500 500 500 Depth(C) (mm) 324 324 324 324 324 324 324 324 324 Net weight Gross weight (kg) (kg) 52 62 52 62 52 62 53 63 53 63 53 63 53 63 53 63 53 63 Outdoor Unit MODEL HBI060C HBI080C HBI100C Height (A) (mm) 791 791 791 Width (B) (mm) 921 921 921 Depth (C) (mm) 427 427 427 Net weight Gross weight (kg) (kg) 66 71 69 74 69 74

A A

B C
Outdoor unit Height (A) MODEL (mm) HBI120C 1253 HBI140C 1253 HBI160C 1253 HBI120CT 1253 HBI140CT 1253 HBI160CT 1253 Width (B) (mm) 950 950 950 950 950 950 Depth (C) (mm) 412 412 412 412 412 412 Net weight Gross weight (kg) (kg) 99 108 99 108 99 108 99 108 99 108 99 108 Storage Tank MODEL HBI200WT / WTS HBI300WT / WTS Height (A) (mm) 1595 1620 Width (B) (mm) 540 620 Net weight* Gross weight (kg) (kg) 68 / 71 77 / 80 82 / 87 92 / 97

* Weight when empty

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

137

Cod.: SHBIUY.01 / 1201

NEW

CL

025/200

Air cooled chiller and heat pump with plug fan Cooling Capacity from 5,82 to 40,34 kW Heating capacity from 7,92 to 44,00 kW

R410A
Aermec participates in the EUROVENT Program: LCP/A/P/R The products of interest can be found on the website www.eurovent-certification.com

HEAT PUMP OPTIMISED FOR HEATING: PRODUCTION OF HOT WATER UP TO 60C HEATING OPERATION WITH EXTERNAL TEMPERATURES FROM -15C TO 42C INTERFACES WITH VARIABLE MULTIFLOW VMF SYSTEM EVAPORATING AND CONDENSING CONTROL STANDARD INVERTER PLUG FAN
Characteristics
Available in 10 sizes Cooling only and heat pump models "H" Manufactured with refrigerant R410A Versions available: "" Standard "P" With pump, expansion tank and water filter "A" With pump, expansion tank, water filter and buffer tank All versions are available for the production of chilled water down to -6C (see unit configurator option) Compressors isolator and mains isolator standard on all models

AVAILABLE VERSIONS: STANDARD WITH PUMP WITH PUMP AND BUFFER TANK DOMESTIC HOT WATER (DHW) PRODUCTION WITH EXTERNAL TEMPERATURES FROM -15C TO 42C

Horizontal or vertical air discharge site adjustable for all sizes Plastic directional air discharge hood for sizes 050 to 090 Galvanised steel directional air discharge hood for the other sizes High Efficiency Scroll Compressor Compressor crank case heater standard Water filter and flow switch standard on all versions Plug fans with EC Inverter motors conforming to regulation EU 327/2011 Through continuous fan speed control permits

operation in cooling mode with external temperatures down to -10C and in heating mode with external temperatures up to 42C Electronic controller with start timers and optimisation of defrost cycles High efficiency plate heat exchanger Plate heat exchanger anti-freeze electric heater "KR" standard on heat pump "H" models Condensate drain tray standard on heat pump "H" models Anti-freeze electric heater standard for the buffer tank

Accessories
AERSET: The AERSET accessory allows the automatic compensation of the operating setpoint of the unit to which it is connected, based on a 0-10V MODBUSinput signal. Mandatory accessory: AER485 or MODU-485A MODU - 485A: RS-485 interface for supervising systems with MODBUS protocol. (accessory mandatory for the production of domestic hot water). DRE: Electronic soft starter. Reduces starting current by about 30%. Factory fitted only. KR: Plate heat exchanger anti-freeze electric heater (only available for cooling only versions) Factory fitted only. PR3: Simplified remote panel. Permits control of basic unit functions and alarm notification. Remote mounted with shielded cable up to 30 m distance. VT: Anti-vibration mounts. CLPA: Galvanised steel plenum to be installed on the condenser coil. Facilitates duct installations. GPCL: Protective grille. Protects the external condenser coil from damage. KR B4/B5/B6: Electric base heater to prevent the formation of ice (only available for heat pump versions). BSKW: External electric heater kit of various capacities with single and three phase power supplies: - BS4KW230M (4kW, 230V/1/50Hz) - BS6KW230M (6kW, 230V/1/50Hz) - BS6KW400T (6kW, 400V/3/50Hz) - BS9KW400T (9kW, 400V/3/50Hz) MULTICONTROL: can be used as a remote panel for a single unit or to simultaneously control several chillers or heat pumps (up to 4) installed in the same hydraulic system, fitted with our MODUCONTROL controller. For complete control the following accessories are available: - SPLW: System water temperature sensor. In most cases the loose supplied sensors for each chiller/heat pump are sufficient. In cases of a common flow/ return header this sensor can be used to control the common system supply water temperature for the chillers connected to the header, or it can be used for temperature monitoring. - SDHW: Domestic hot water temperature sensor. Used with the storage tank to control the temperature of water produced. AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: - AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; - AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; - AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; - AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; COMPATIBILITY with the VMF SYSTEM For more information on the system refer to the manual.

138

Unit configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system requirements. Conguration elds 12 | Code 345 | | | Size 6 | Model 7 | | | Execution 8 | Version 9 | | | Heat recovery 10 | Coil 11 | | | Field of use 12 | Evaporator 13 | | | Power supply

Code: CL Size: 025, 030, 040, 050, 070, 080, 090, 100, 150, 200 Model: - Cooling only H- Heat pump Execution - Standard L - Low noise Version: - Standard P- With pump A- With pump and buffer tank Heat recovery: - Without heat recovery D - With desuperheater (for Cooling only models sizes 050 to 200)

Coil: - Aluminium R- Copper S- Tinned copper V- Epoxy coated aluminium Field of use: - Standard Z - Low temperature leaving liquid from +4C to 0C Y -Low temperature leaving liquid from 0C to -6C Evaporator: - Standard C- Condensing unit Power supply: - 3N~ 400V 50Hz M - 1~ 230V 50Hz (only for sizes 025 to 040) 3 - 3~ 230V 50Hz (only for sizes 090 and 200, for other sizes contact the factory)
Heat pump "H" model not possible with: - thermostatic expansion valve "Z" - "Y" - condensing unit "C" - desuperheater "D" - low noise "L" Heat recovery "D" not possible with: - thermostatic expansion valve "Z" - "Y" - condensing unit "C"

WARNING The integral buffer tank of the CLH unit refers to the system and not to the production of domestic hot water.

CL "" COOLING ONLY "H" HEAT PUMP


(1) (1) (1)

25 Power supply All All All All All 3N~ 400V 50Hz 3N~ 400V 50Hz All All / H / P / HP A / HA All - 485A All All 3N~ 400V 50Hz 1~ 230V 50Hz All All All All All 9 15A 1 5 1 H Std 9 15A 1 5 1 9 15A 2 5 2

30 H Std 9 15A 2 5 2 9 15A 2 5 2

40 H Std 9 15A 2 5 2 9 15A 2 5 2

50 H Std 9 15A 2 5 2 9 15A 2 5 2

70 H Std 9 15A 2 5 2 9 15A 2 5 2

80 H Std 9 15A 2 5 2 9 15A 2 5 2

90 H Std 9 15A 2 5 2 15 15 3

100 H Std 15 15 3 15 15 3

150 H Std 15 15 3 15 15 3

200 H Std 15 15 3

KRB4 KRB5 KRB6

BS4KW230M BS6KW230M BS6KW400T BS9KW400T


(1)

KR2

PR3 VT AERSET
(2) MODU (3) CLPA (4) DRE (1) GPCL

5 (x2) 5 (x2) 5 (x2) 5 (x2) 5 (x2) 5 (x2) 3 3 3 3 3 3

MULTICONTROL SPLW SDHW AERWEB300

Power supply 1~ 230V 50Hz is available only for sizes 025 - 030 - 040 (1) Accessory factory tted only (2) Accessory mandatory for the production of domestic hot water (3) Not available with accesory GPCL only for sizes 025 to 090 (4)DRE for power supply 1~ 230V 50Hz / 3~ 230V 50Hz

Std -

Available accessory Fitted as standard Not available

139

Technical data
Model "" COOLING ONLY Cooling capacity Total power input Water flow rate Total Pressure drop Available pump head ENERGY EFFICIENCY EER ESEER ELECTRICAL DATA Total current input A P/A P/A P/A Version H HP/HA H HP/HA H H HP/HA H HP/HA H HP/HA HP/HA H HP/HA H HP/HA H HP/HA H HP/HA H HP/HA H HP/HA H HP/HA H HP/HA Version L LP/LA L LP/LA All L LP/LA L LP/LA L LP/LA L LP/LA L LP/LA L LP/LA Units kW kW l/h kPa kPa W/W W/W Version P/A P/A All P/A P/A P/A Power supply All All All All All All All All All All All 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz Power supply 400V/3N/50Hz 400V/3N/50Hz 400V/3N/50Hz 400V/3N/50Hz All All All All All All All All All All All All All All All All 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz Power supply 400V/3N/50Hz 400V/3N/50Hz 400V/3N/50Hz 400V/3N/50Hz All All All 400V/3N/50Hz 400V/3N/50Hz 400V/3N/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 230V/1/50Hz 400V/3N/50Hz 025 5,82 5,87 2,09 2,12 1009 19,00 58,26 2,79 2,77 3,23 3,21 10,14 4,80 10,91 5,57 21,6 11,1 22,57 12,07 66,6 37,6 67,57 38,57 025 6,39 6,44 2,54 2,57 1105 13,00 63,81 7,92 7,85 2,24 2,25 1406 19,00 57,50 2,51 2,51 3,53 3,48 2,92 2,91 12,7 5,50 13,48 6,28 11,8 5,50 12,59 6,29 18,80 11,01 19,77 11,98 86,10 44,60 87,07 45,57 025 5,65 5,70 2,13 2,17 979 18,23 59,40 2,65 2,63 3,13 3,11 9,93 4,31 10,70 5,08 21,6 11,1 22,57 12,07 66,6 37,6 67,57 38,57 030 7,11 7,18 2,55 2,57 1234 26,00 49,17 2,79 2,80 3,27 3,28 12,99 5,10 13,77 5,88 24,6 11,6 25,57 12,57 87,6 40,6 88,57 41,57 030 8,35 8,42 2,98 2,99 1442 12,00 63,08 9,79 9,70 2,86 2,85 1740 16,00 58,79 2,80 2,82 3,42 3,40 3,29 3,31 15,4 6,30 16,20 7,10 14,3 6,20 15,11 7,01 23,70 11,96 24,67 12,93 95,51 44,60 96,48 45,57 030 6,90 6,97 2,60 2,62 1197 24,76 50,36 2,66 2,66 3,16 3,17 12,79 4,70 13,57 5,48 24,6 11,6 25,57 12,57 87,6 40,6 88,57 41,57 040 8,80 8,89 3,47 3,47 1525 25,00 49,63 2,54 2,56 2,98 3,01 16,91 7,50 17,71 8,30 24,7 12,6 25,67 13,57 117,6 71,6 118,57 72,57 040 10,34 10,44 3,56 3,55 1787 13,00 60,09 12,52 12,39 3,45 3,42 2113 18,00 53,54 2,91 2,94 3,63 3,62 3,25 3,29 16 6,70 16,81 7,51 15,66 6,50 16,49 7,33 24,00 11,92 24,97 12,89 96,14 57,18 97,11 58,15 040 8,53 8,62 3,51 3,51 1479 23,57 51,88 2,43 2,46 2,89 2,92 16,83 6,90 17,63 7,70 24,7 12,6 25,67 13,57 117,6 71,6 118,57 72,57 7 C 12 C 35 C 050 12,65 12,80 4,03 4,02 2191 27,00 79,21 3,13 3,18 3,73 3,79 8,53 9,88 13,68 15,63 77,18 79,13 050 11,90 12,03 3,93 3,94 2055 11,00 98,55 14,47 14,30 3,88 3,86 2476 17,00 92,80 3,03 3,06 3,72 3,71 3,41 3,44 7,68 9,02 7,64 9,02 13,50 15,45 64,18 66,13 050 12,14 12,29 4,21 4,21 2104 25,16 81,94 2,88 2,92 3,48 3,53 8,97 10,31 13,68 15,63 77,18 79,13 070 16,28 16,47 5,24 5,19 2820 29,00 74,42 3,11 3,17 3,63 3,71 10,23 11,64 15,38 17,33 77,18 79,13 070 13,96 14,12 4,60 4,58 2413 15,00 92,73 15,95 15,76 4,52 4,47 2727 21,00 88,35 3,04 3,08 3,53 3,52 3,42 3,47 8,38 9,75 8,18 9,58 14,68 16,63 74,18 76,13 070 15,63 15,82 5,42 5,37 2707 26,64 77,50 2,89 2,94 3,43 3,49 11,27 12,67 15,38 17,33 77,18 79,13 080 18,30 18,51 6,45 6,38 3170 30,00 71,35 2,84 2,90 3,29 3,37 12,03 13,47 16,98 18,93 77,18 79,13 080 15,49 15,67 5,37 5,34 2678 17,00 87,84 18,61 18,39 5,24 5,17 3181 26,00 79,25 2,89 2,94 3,55 3,56 3,25 3,31 9,77 11,16 9,34 10,78 15,15 17,10 94,18 96,13 080 17,57 17,78 6,55 6,49 3043 27,60 74,65 2,68 2,74 3,13 3,18 12,64 14,07 16,98 18,93 77,18 79,13 090 20,14 20,37 6,53 6,45 3487 29,00 70,62 3,08 3,16 3,56 3,64 12,89 14,36 20,38 22,33 105,18 107,13 090 18,92 19,14 6,52 6,46 3275 26,00 75,11 21,06 20,81 6,32 6,22 3597 34,00 69,77 2,90 2,96 3,33 3,35 3,27 3,38 13,42 14,87 12,71 14,19 20,38 22,33 105,18 107,13 090 18,54 18,75 7,26 7,20 3208 24,46 77,20 2,55 2,61 3,00 3,06 13,64 15,09 20,38 22,33 105,18 107,13 100 26,16 24,34 8,47 8,53 4538 45,00 82,63 3,09 2,85 4,64 4,68 16,72 17,85 27,36 29,32 90,86 92,82 100 23,82 24,34 7,85 7,91 4126 34,00 99,30 27,98 27,41 7,79 7,83 4772 49,00 81,15 3,04 3,08 3,59 3,50 4,54 4,55 14,34 15,43 14,34 15,50 27,00 28,96 77,68 79,64 100 24,09 24,60 9,46 9,53 4175 38,49 91,23 2,55 2,58 3,89 3,91 18,54 19,64 27,36 29,32 90,86 92,82 150 32,86 31,94 10,78 10,98 5701 53,00 131,17 3,05 2,91 4,55 4,60 19,76 21,55 30,76 33,84 92,56 95,64 150 31,21 31,94 10,43 10,70 5394 22,00 157,54 34,92 34,14 10,12 10,39 5971 30,00 143,90 2,99 2,99 3,45 3,29 4,42 4,45 21,25 23,00 19,45 21,29 30,30 33,38 109,33 112,41 150 31,56 32,35 11,08 11,29 5473 48,96 137,40 2,85 2,87 4,31 4,34 20,20 21,96 30,76 33,84 92,56 95,64 200 40,34 38,31 13,83 13,97 7009 72,00 121,75 2,92 2,74 4,51 4,53 25,36 27,33 40,76 43,84 125,56 128,64 200 37,43 38,31 13,73 13,93 6484 43,00 144,36 44,00 43,03 13,84 14,03 7346 62,00 116,78 2,73 2,75 3,18 3,07 4,21 4,21 26,61 28,51 26,49 28,53 40,76 43,84 125,56 128,64 200 37,27 38,20 14,11 14,26 6472 66,38 129,38 2,64 2,68 4,14 4,15 26,10 28,00 40,76 43,84 125,56 128,64

Maximum current (FLA)

Staring current (LRA)

Model "H" HEAT PUMP Cooling capacity Total power input Water flow rate Total Pressure drop Available pump head Heating capacity Total power input Water flow rate Total Pressure drop Available pump head ENERGY EFFICIENCY EER COP ESEER ELECTRICAL DATA Total current input ( cooling)

U.M. kW kW l/h kPa kPa kW kW l/h kPa kPa W/W W/W W/W

Total current input (heating)

Maximum current (FLA)

Staring current (LRA)

Model "L" LOW NOISE Cooling capacity Total power input Water flow rate Total Pressure drop Available pump head ENERGY EFFICIENCY EER ESEER ELECTRICAL DATA Total current input

Units kW kW l/h kPa kPa W/W W/W

Maximum current (FLA)

Staring current (LRA)

- Data in accordance with UNI EN 14511-2011 - All data refers to nominal available fan static pressure

COOLING Evaporator water outlet temperature Evaporator water inlet temperature External air temperature

HEATING Condenser water inlet temperature Condenser water outlet temperature External air temperature

40 C 45 C 7C db / 6C wb

140

Technical data
GENERAL DATA SCROLL COMPRESSOR Quantity / circuits PLATE HEAT EXCHANGER Quantity Hydraulic connections (victaulic) PLUG FAN - EC INVERTER MOTOR Quantity Air ow rate Power input Nominal available fan static pressure Maximum available fan static pressure BUFFER TANK Capacity EXPANSION TANK Numbe/Capacity SOUND DATA Radiated sound power Radiated sound pressure Discharge sound power Discharge sound pressure Units n/n n n m3/h kW Pa Pa l n/l dB(A) dB(A) dB(A) dB(A) Version All All All H L H L All All A P/A H L H L H L H L Power supply All All All All All All All All All All All All All All All All 025 1/1 1 1" 1/4 1 4000 4000 3000 0,34 0,34 0,16 50 300 50 1/2 78,3 78,3 70,6 46,3 46,3 38,6 78,3 78,3 70,7 46,3 46,3 38,7 030 1/1 1 1" 1/4 1 4000 4000 3000 0,34 0,34 0,16 50 300 100 1/5 78,3 78,3 70,6 46,3 46,3 38,6 78,3 78,3 70,7 46,3 46,3 38,7 040 1/1 1 1" 1/4 1 4000 6500 3000 0,34 0,62 0,16 50 300 100 1/5 78,3 73,0 70,6 46,3 41,0 38,6 78,3 77,9 70,7 46,3 45,9 38,7 7 C 12 C 35 C 050 1/1 1 1" 1/4 1 6500 6500 4000 0,62 0,62 0,24 80 400 100 1/5 73,0 73,0 68,9 41,0 41,0 36,9 77,9 77,9 67,8 45,9 45,9 35,8 070 1/1 1 1" 1/4 1 6500 6500 4000 0,62 0,62 0,24 80 400 100 1/5 73,0 73,0 68,9 41,0 41,0 36,9 77,9 77,9 67,8 45,9 45,9 35,8 080 1/1 1 1" 1/4 1 6500 6500 5000 0,62 0,62 0,36 80 400 100 1/5 73,0 73,0 68,9 41,0 41,0 36,9 77,9 77,9 67,8 45,9 45,9 35,8 090 1/1 1 1" 1/4 1 7500 7500 5000 0,83 0,83 0,36 80 400 100 1/5 75,7 75,7 68,9 43,7 43,7 36,9 80,9 80,9 67,8 48,9 48,9 35,8 100 2/1 1 1" 1/4 2 10000 10000 6000 0,95 0,95 0,33 80 400 100 1/8 74,4 74,4 65,6 42,4 42,4 33,6 78,0 78,0 63,1 46,5 46,5 31,6 150 2/1 1 1" 1/4 2 12000 12000 8500 1,76 1,76 0,83 100 400 100 1/8 78,7 78,7 71,7 46,7 46,7 39,7 83,4 83,4 72,6 51,9 51,9 41,1 200 2/1 1 1" 1/4 2 12000 16000 8500 1,76 2,72 0,83 100 400 100 1/8 78,7 80,4 71,7 46,7 48,4 39,7 83,4 85,1 72,6 51,9 53,6 41,1

- Data in accordance with UNI EN 14511-2011 - All data refers to nominal available fan static pressure

COOLING Evaporator water outlet temperature Evaporator water inlet temperature External air temperature

HEATING Condenser water inlet temperature Condenser water outlet temperature External air temperature

40 C 45 C 7C db / 6C wb

SOUND POWER Sound power measured with intensity method in accordance with UNI EN ISO 9614-1, as required for Eurovent certication.

SOUND PRESSURE Sound pressure measured in free eld over a reective plane at a distance of 10m and directivity factor of 2. In accordance with ISO 3744 standard. Power supply 400V.

Dimensional data (mm)


DIMENSIONS - WEIGHTS without packaging - "" COOLING ONLY / "L" LOW NOISE Version Units 025 030 040 050 070 080 Height (A) All mm 1028 1281 1281 1281 1281 1281 -P mm 1005 1006 1006 1160 1160 1160 Width (B) A mm 1366 1458 1458 1610 1610 1610 Depth (C) All mm 702 754 754 798 798 798 kg 127 160 160 208 210 210 Weight empty P kg 133 166 166 217 225 225 A kg 157 201 201 252 260 260 DIMENSIONS - WEIGHTS without packaging - "H" HEAT PUMP Version Units 025 030 040 Height (A) Tutte mm 1028 1028 1281 H HP mm 1005 1005 1160 Width (B) HA mm 1366 1366 1610 Depth (C) Tutte mm 702 702 798 H kg 142 142 229 Weight empty HP kg 148 148 239 HA kg 172 172 274 050 1281 1160 1610 798 229 239 274 070 1281 1160 1610 798 240 250 284 080 1281 1160 1610 798 240 250 284 090 1281 1160 1610 798 212 221 256 090 1281 1160 1610 798 234 243 279 100 1674 1897 1897 801 469 482 532 100 1674 1897 1897 801 504 517 567 150 1674 1897 1897 801 471 487 537 150 1674 1897 1897 801 527 543 593 200 1674 1897 1897 801 475 492 542 200 1674 1897 1897 801 515 531 581

A B C A

B
Discharge hood possible configurations (site modified)
CL 025 - 040 CL 040H-050-090 CL100-200

Sizes 020 to 090

C
Sizes 100 to 200
Cod.: SCLUY.02 / 1302

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

141

SRA

Heat pumps only for hot water production systems, up to 65C, and domestic hot water up to 50 C Heating capacity from 10 up to 18 kW

STANDARD VERSION VERSION EQUIPPED WITH CIRCULATION PUMP VERSION EQUIPPED WITH OVERSIZED PUMP HOT WATER PRODUCTION FOR SYSTEM, UP TO 65 C PRIORITY DIRECTED TO DOMESTIC HOT WATER (A.C.S.) UP TO 50 C
Features
SRA is a line of heat pumps with air-cooled condensing units that use the refrigerant R470C. They heat water up to 65C and can operate down to -15C, with prioritized production of domestic hot water. These are external units with hermetic Scroll compressors that perfectly meet the needs of the residential and services markets: reduced dimensions, easy installation, and quiet. High energy efficiency SRA heat pumps were designed to offer high efficiency in all use conditions. Particular care was taken with the heat pump performance. The components chosen provide high energy efficiency, with a notable decrease in consumption. Performance down to -15 C SRA heat pumps were designed with a focus on winter performance. Next generation regulation guarantees that the heat pump will function well beyond the normal limits of traditional units. maintain water temperature at the perfect level. Dynamic set point SRA heat pumps come with an external air temperature sensor. Based on the external conditions, the regulator automatically modifies the system's water temperature set point, improving energy efficiency for the system. Priority directed to domestic hot water (A.C.S.) The unit guarantees production of domestic hot water up to 50 C, as long as the appropriate domestic hot water storage (ACCESSORY) is included, and the guarantee is valid for both summer and winter. Advantages The technological choices made, always focused on maximum quality and the use of the most innovative technology, mean that SRA offers high efficiency, easy installation, and a wide range of usage options. ON-OFF pump. (A heavy duty pump is also available N.) Technical Features High output scroll compressor and low electricity consumption Differential pressure switch Conforms to CE safety directives and to electromagnetic compatibility norms. Device safety is guaranteed by the disconnecting switch door lock found on the power supply electrical panel, which is integrated in the unit, as well as by active protection on the main components Controls are accessible externally, with a user interface display that shows all performance parameters in four languages Next generation regulation Easy to use remote control panel with alarms included

Available in three sizes As a option is possible installation integrated SRA: Heat pump with production of domeresistance stic hot water. Available with three-phase or SRA heat pumps can be integrated with resistansingle-phase power supply. The single-phase ce directly managed by the unit's electronics. version comes with soft-start installed. Resistance activation depends on external air SRA P: Heat pump with production of dometemperature and the temperature of the water in stic hot water. Available with three-phase or the system, making it possible to constantly single-phase power supply and integrated

142

Accessories
VT: Anti-vibration supports, a group of four antivibrating supports to be placed under the sheet steel foundation of the unit. DHW: Management kit with the components necessary for production of domestic hot water (anti-legionella cycle included). S...S: Domestic hot water storage, available in 300, 400, and 500 litres (S300S, S400S, and S500S). S...I: System storage; available in 200, 300, 400, and 500 litres (S200I, S300I, S400I, and S500I) RXS: Domestic hot water storage resistance; available in 3kW single phase (RXS3M), or in 3 - 6 - 8 kW three phase (RXS3T, RXS6T, RXS8T). MODU-485A: RS-485 interface for supervision systems with MODBUS protocol. AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; PR3: Simplified remote panel. This makes it possible to carry out the unit's basic controls with the signalling of alarms. Can be made remote with shielded cable up to 150 m. Compatibility with the VMF system VMF-CRP VMF-VOC VMF-ACS VMF-E5B|N For more information refer to the documentation dedicated.

Accessory compatibility
Mod. SRA VT MODU-485A AERWEB300 PR3 S300S S400S - S500S S200I - S300I - S400I -S500I 10M 15 10T 15 14M 15 14T 15 19T 15

COMPATIBILITY BETWEEN DOMESTIC HOT WATER STORAGE AND DOMESTIC STORAGE RESISTANCE (RXS) RXS3M RXS3T RXS6T RXS8T S300S S400S S500S

Unit selection
By judiciously combining the numerous options available, each model can be configured in a way that satisfies the most specific system needs. Configuration rules: 1 2 3 45 6 7 8 9 | | | | | | Code | | | | Power supply | Soft-start kit | version Size electric resistances Code: SRA Size: 10 - 14 - 19 Version: - Standard P - with pump N - with oversized pump Soft-start: (factory installed for single phase versions) - Standard S - With Soft-start kit (to be factory installed) Integrated resistances: - Without integreted resistance R - With electric resistances Power supply: M - 1~ 230V 50Hz (only for sizes 10 and 14) T - 3N~ 400V 50Hz

SRA

143

Technical data
Mod. SRA Heating capacity P Total power input P Total current input P N C.O.P. P Water cond. flow rate P Pressure drops Available pressure P N Maximum current (FLA) P Peak current with soft start (LRA) Peak current with soft start (LRA) Compressors N compressors/N circuits Part load Refrigerant Condenser Number Hydraulic connections Integrated resistance OPTIONS Number Capacity Fans Number Air flow rate Sound data Sound power Sound pressure Performance is in line with norms UNI EN 14511-2: 2008 H H All 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230V/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N 230/1 400V/3N kW kW kW kW kW kW kW kW A A A A A A W/W W/W W/W W/W l/h l/h l/h l/h kPa kPa kPa A A A A A A A A n/n % type N n kW All All All All n m3/h dB(A) dB(A) 2 7.200 69 37 2 7.200 69 37 10M 10,03 9,9 10T 10,10 10,08 14M 14,00 13,8 14T 14,10 13,9 19T 18,34 18,15

2,52
2,61 13,1 14,1 14,5 3,98 3,79 1730 1700 18 62 91 22,4 23,3 45 100 1/1 0 - 100

2,29 2,41 4,6 3,6 4,0 4,41 4,18 1740 1720 19 61 90 7,4 8,3 30 42 1/1 0 - 100

3,69
3,74 21,0 22,0 22,6 3,79 3,69 2410 2370 36 52 83 31,4 32,3 45 162 Scroll 1/1 0 - 100 R407C Plate 1 F / 1" 1 11,5 Axial 2 6.800 70 38

3,57 3,62 6,1 7,1 7,7 3,95 3,84 2430 2390 36 51 82 11,4 12,3 46 66 1/1 0 - 100

4,70 4,52 8,8 9,8 10,4 3,87 3,80 3150 3120 39 35 70 15,4 16,4 73 104 1/1 0 - 100

All All

1 F / 1"

1 F / 1"

1 F / 1"

1 F / 1"

2 6.800 70 38

2 6.800 71 39

Heating Condenser Input temperature 30C; Output temperature 35C; t 5C External air temperature 7bs / 6bu

Sound power Aermec determines the value, based on the measurements made, in accordance with ISO 9614-2 norms

Sound pressure Measured in a free field frontal distance, 10 m and directionality = 2, in conformance with ISO 3744 norms

144

Technical data (400V/3N/50Hz)


A2/W35 Heating capacity Total power input C.O.P. Water cond. flow rate (1) Pressure drops Available pressure Air flow rate Sound pressure Sound power P P P kW kW kW kW kW kW l/h kPa kPa m3/h dB(A) dB(A) SRA10T 8,03 7,95 2,25 2,37 SRA14T 11,33 11,17 3,45 3,49 SRA19T 15,06 14,58 4,76 4,56 TECHNICAL DATA UNI EN 14511-2: 2008 NOTE: A Ambient air temperature W Condenser outlet water temperature (1) The water flow rate declared: Condenser inlet water temperature 30C Condenser outlet water temperature. 35C Ambient air temperature 7C b.s. / 6 C b.u. Sound power Aermec determines sound power values on the basis of measurements made in compliance with the ISO 9614-2 Standard, in agreement with that requested by Eurovent certification Sound pressure Sound pressure in free field conditions on reflective surface (directivity factor Q=2) at 10 mt from the external surface of unit, in compliance with ISO 3744 regulations.

3,569
3,354 1720 19 61 7200 37 69

3,284
3,201 2430 37 51 6800 38 70

3,164
3,197 3180 40 44 6800 39 71

P All All All

Dimensions (mm)

384

1124

1252
SRA (/P/N) Height Width Depth mm mm mm 10 1252 1124 384/428 14 1252 1124 384/428 19 1252 1124 384/428

428

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

145

Cod.: SSRAUY.03 / 1201

SRP
R407C

High Temperature AIR/WATER Heat Pump only With PLUG FAN fans and heating capacity from 10 up to 19 kW

INDOOR INSTALLATION

OUTDOOR INSTALLATION

ELECTRICAL PANEL TECHNICAL ROOM

HEAT PUMP UNIT TO PRODUCE HOT WATER UP TO 65C WITH EXTERNAL TEMPERATURE OF -20 C OPERATING LIMITS FROM -20C UP TO 42C (AMBIENT TEMPERATURE) Features
Maximum safety under all working conditions. These heat pumps can produce hot water up to 65C. They can also operate with outside temperatures ranging between -20C and 42C, always ensuring continuous operation. Available in 3 sizes and two versions Outdoor or indoor installation Possible plants layout : no. 70 - 71 - 72 - 74 (ref. to technical / installation mnaual) Main characteristics: Water filter Safety valve for enhanced efficiency Scroll type compressors Electric resistor for platetype exchanger. - High level of reliability PLUG-FAN fan with highhead and particularly - High efficiency silent operation Electronic regulator capable of managing a double The units are characterised by being very compact function- controlling the heat pump and are varnished with polyester powders to proand managing the hydraulic system components tect them against atmospheric agents. (Storage system, domestic hot water (DHW) storage, a three-way valve (1 max), mixing valve (1 max), pumps (3 max), probes, etc.). Platetype exchanger externally insulated with a closed cell cover that minimises heat loss. Optimised

Accessories
VT: Anti-vibration mountings, set of four vibrationdamping components to fit under the steel base of the unit. S...S: Domestic hot water (DHW) storage; available in three different capacities: 300, 400 and 500 litres (S300S, S400S and S500S). RXS: Electric resistors for domestic hot water (DHW) storage; available in two models: single-phase, 3 kW (RXS3M), or three-phase, 3 - 6 - 8 kW (RXS3T, RXS6T, RXS8T). S...I: Storage system; available in four different capacities: 200, 300, 400 and 500 litres (S200I, S300I, S400I and S500I). AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; TASRP: Room temperature probe, it allows users to set the room air value, with a correction of 3C. TADSRP: Room temperature probe with display, it offers all the same functions available with Elesta control electronics. QLT: (Obligatory accessory) Electrical panel of the technical room containing the Elesta control electronics, and the power and safety components necessary for the unit to function; this accessory is available in different presentations (wired according to the type of unit chosen): - QLT10RT, electrical panel for SRP10 with domestic hot water (DHW) storage managed by a three-phase resistor; - QLT10T, electrical panel for SRP10 , three-phase standard; - QLT14RT, electrical panel for SRP14 with domestic hot water (DHW) storage managed by a three-phase resistor; - QLT14T, electrical panel for SRP14 , three-phase standard; - QLT14RM, electrical panel for SRP14 with domestic hot water (DHW) storage managed by a single-phase resistor; - QLT14M, electrical panel for SRP14 , single-phase standard; - QLT19RT, electrical panel for SRP19 with domestic hot water (DHW) storage managed by a three-phase resistor; - QLT19T, electrical panel for SRP19 , three-phase standard; FV: (Compulsory Accessory) Flange for airside channelling, needed for indoor installation; COVE: (Compulsory accessory) Upper metal cover, needed for Outdoor installation , painted with polyester powders to protect units against atmospheric agents;

146

Accessory compatibility
SRP COMPULSORY ACCESSORIES: QLT M (single-phase units without domestic water resistors) QLT RM (single-phase units with domestic water resistors) QLT T (three-phase units without domestic water resistors) QLT RT (three-phase units with domestic water resistances) FV COVE 10T 14M 14T 19T

OPTIONAL ACCESSORIES:
TASRP TADSRP VT 9

AERWEB300 (SRP-V1)
S300S S400S - S500S S200I - S300I - S400I -S500I RXS3M RXS3T - RXS6T - RXS8T

COMPATIBILITY BETWEEN DOMESTIC HOT WATER (DHW) TANKS AND ELECTRIC RESISTORS FOR DOMESTIC WATER STORAGE (RXS)
S300S S400S S500S

Is there a version marked by the initials V1, equipped with simplified electronics can handle the drive and the production of hot water; With the SRP - V1 is no longer necessary accessories QLT, and TDASRP TASRP; for remote control of this version is available PR3 AERWEB300 and accessory kits are 2 pumps (for KPSRP14 SRP10-14 / KPSRP19 for SRP19) Optional accessories only at the factory. Compatibility with the VMF system: VMF-CRP - VMF-VOC - VMF-ACS - VMF-E5B|N - For more information refer to the documentation dedicated. Example of commercial code: SRP 14 T - V1 (with simplified electronic version)

Choice of Unit
Field configurer:

1 2 3 4 5 6 7 8 9 | | | | | | Code | Ventilation | Supplementary | | | elect. resistance | Size Soft start kit | Power supply By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system requirements.

Code: SRP Size: 10 - 14 - 19 Ventilation: - Standard Soft-start: (standard for the single-phase version) - Standard S - With Soft-Start kit (to be assembled in the factory)

Supplementary elect. resistors: - Standard (without supplementary electric resistors) R - With supplementary electric resistors Power supply: * M - 230V~50Hz T - 400V 3N~ 50Hz

* Single-phase supply available only for SRP 14M.

147

TEMPERATURE TEMPERATURE OF -20 C OF -20 C OPERATING OPERATING LIMITS FROM LIMITS -20C FROM UP TO -20C 42C UP (AMBIENT TO 42C TEMPERATURE) (AMBIENT TEMPERATURE)

Installation example
indoor installation Outdoor installation

SRP

buffer tank system Domestic hot water (DHW) storage

SRP

buffer tank system

Domestic hot water (DHW) storage

Technical data
Mod. Heating capacity Total power input Total current input Starting current with soft start Starting current COP Water flow rate Pressure drops Sound pressure Sound power Air flow rate Hydraulic connections Supporting electric resistors 400V 3N~ 50Hz 230V ~ 50Hz 400V 3N~ 50Hz 230V ~ 50Hz 400V 3N~ 50Hz 230V ~ 50Hz 400V 3N ~ 50Hz SRP10T 10 2,6 / 5,9 / 30 / 43 3,85 1.720 12,5 34,7 66,7 3.500 1 1 8,2 SRP14M 14,0 / 3,66 / 22,0 / 45 / 3,82 2.410 24,0 35,5 67,5 3.500 1 1 11,5 SRP14T 14,1 3,4 / 7,3 / 46 / 67 4,15 2.425 24,0 35,5 67,5 3.500 1 1 11,5 SRP19T 19,1 4,72 / 11,7 / 73 / 105 4,05 3.285 30,0 41,0 73,0 5.000 1 1 15,5

kW kW A A A W/W l/h kPa dB(A) (IN) (OUT) m3/h kW

Data stated according to EN14511: 2008 Heating: - water outlet temperature 35 C; - outside air temperature 7 C B.S., 6 C B.U.; - t = 5 C.

Sound pressure Measured in a free field frontal distance, 10 m and directionality = 2, in conformance with ISO 3744 norms Sound power Aermec determines the value, based on the measurements made, in accordance with ISO 9614-2 norms

Technical data (400V/3N/50Hz)


A2/W35 Heating capacity Total power input COP Water flow rate 1 Pressure drops Air flow rate Sound pressure Sound power TECHNICAL DATA UNI EN 14511-2: 2008 NOTE: A Ambient air temperature W Condenser outlet water temperature 1 The water ow rate declared: Condenser inlet water temperature. Condenser outlet water temperature. Ambient air temperature SRP10T 7,62 2,17 3,52 1680 12 3500 35 66,7 SRP14T 11,33 3,29 3,44 2430 24 3500 36 67,5 SRP19T 15,34 4,56 3,36 3290 30 5000 41 73

kW kW kW l/h kPa m3/h dB(A) dB(A)

30C 35C 7C b.s. / 6 C b.u.

Sound power Aermec determines sound power values on the basis of measurements made in compliance with the ISO 9614-2 Standard, in agreement with that requested by Eurovent certification Sound pressure Sound pressure in free field conditions on reflective surface (directivity factor Q=2) at 10 mt from the external surface of unit, in compliance with ISO 3744 regulations.

148

Dimensions (mm)
B

B C

Height Width Depth Weight

A B C kg

Outdoor Installation Indoor installation Outdoor installation Indoor installation Outdoor installation Indoor installation

SRP10 T 1427 1115 1322 812 1392 284 242

SRP14 M/T 1427 1115 1322 812 1392 297 255

SRP19 T 1427 1115 1322 812 1392 315 273

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

149

Cod.: SSRPUY.08 / 1202

SWP

High temperature air cooled heat pumps for the production of domestic hot water

AIR COOLED HEAT PUMPS FOR HOT WATER PRODUCTION UP TO 60C (UP TO 70C WITH AUXILIARY ELECTRIC HEATER) APPLICATION RANGE: IN HEAT PUMP WITH AIR INTAKE FROM 8C TO 35C (EXTENDED FROM -15C TO 45C WITH THE AID OF THE AUXILIARY ELECTRIC HEATER) VERSIONS WITH 300 LITRES STORAGE TANK, OR WITH 1 OR 2 COILS TO BE USED TOGETHER WITH OTHER HEAT SOURCES (SOLAR PANELS, BOILER, HEAT PUMP) AUTOSTART FUNCTION FOR THE UNIT TO RESTART AUTOMATICALLY Features
The SWP heat pumps use the thermal energy of air for production of domestic hot water. The process occurs in the most efficient and profitable way with average COPs > 3. The energy advantage of the SWP heat pumps also safeguards the environment, using most of its energy from solar radiation. Easy installation, silent and reliable functioning and very low maintenance requirements complete the benefits of this highly ecological and economic system. Main features Steel tank with a double vitrification layer with storage capacity of 300 litres, (SWP 300, SWP 300 S1 and SWP 300 S2) Condenser wrapped externally to the boiler with no scales and refrigerant-water fluid contamination Auxiliary coil to be used together with a boiler or solar panels Integrated NTC sensor to control the water temperature External air sensor for automatic connection of the electric heater with unfavourable temperatures in heat pump mode Anti-corrosion magnesium anode Hydraulic connections located at rear of unit Thermal insulation made of very thick expanded polyurethane foam with a silver grey RAL 2006 external covering (ABS) Adjustable support feet Environmentally friendly refrigerant R134a Electric heater 1.5 kW 230V IEC power supply connector with insulating sheath High pressure safety devices Reciprocating hermetic compressor Radial fan with an adjustment of 40 % of the nominal flow rate Electronic controller: - water set point adjustment - external air temperature sensing - auto-diagnostic with display of the high/low pressure alarm, water overheating alarm and disconnected sensors alarm - record of run hours - control of minimum time between successive compressor starts - setting of parameters from the keyboard - control of electric heater in manual mode or in supplementary automatic mode for low external temperatures - periodic antibacterial treatment cycle to eliminate and prevent Legionella from developing - user display to set the operating mode and various parameters with different levels of accessibility by means of passwords Possible configurations Standard where the heat pump and the electric heater are the source of heat ( SWP 300) With auxiliary coil to be used together with a boiler or solar panels (SWP 300 S1) With double auxiliary coils for simultaneous use of three heat sources (SWP 300 S2)

150

Dimensional Data (mm)


SWP 300 SWP 300 S1 SWP 300 S2

Technical Data
Mod. Voltage - phases - frequency Heating capacity in heat pump mode Electric heater power Maximum water temperature Intake air operating range Total input power Max total input current in heat pump mode Max total input current in electric heater mode Compressor Fan Air flow rate Min sound power Max sound power Max ducted length Air ducts minimum diameter Working pressure e Sound pressure level DHW hot water flow connection DHW cold water return connection Heating system return connection Heating system flow connection Recirculation connection Alternative heat source 1 and 2 return connection Net weight Gross weight Storage tank capacity Unit dimensions V-Ph-Hz W W C C W A A Type / number Type / number m3/h dB(A) dB(A) m mm bar dB(A) SWP 300 230 - 1 - 50 2.150 1500 60 +8*/+35 640 3,9 6,8 450 59 71 10 160 6 52 1 1 1 1 1/2 1 116 137 SWP 300 S1 230 - 1 - 50 2.150 1500 60 +8*/+35 640 3,9 6,8 reciprocating/1 centrifugal/1 450 59 71 10 160 6 52 1 1 1 1 1/2 1 94 115 300 1.865 660 660 2.050 770 770 SWP 300 S2 230 - 1 - 50 2.150 1500 60 +8*/+35 640 3,9 6,8 450 59 71 10 160 6 52 1 1 1 1 1/2 1 134 155

Kg Kg

L
Height Width Depth Height Width Depth

Packaging dimensions

Performances in accordance with EN 255-3 Heating: Condenser Inlet temperature 15 C Outlet temperature 50 C External air temperature 15 C

* default settings e Sound pressure measured in free field at a distance of 10m from the front and directivity factor = 2. In accordance with ISO 3744.

Installation Examples
Cod.: SSWPUY.01 / 1212
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

151

NRL
0280/0700 cooling only

Air cooled chillers with axial fans Cooling capacity from 53 kW to 162 kW

R410A

Aermec participate in the EUROVENT program:LCP/A/P/C the products are present on the site www.eurovent-certification.com

COMPACT VERSION LOW NOISE COMPACT VERSION HIGH EFFICIENCY VERSION LOW NOISE HIGH EFFICIENCY VERSION
Characteristics
Available in 9 sizes Refrigerant R410A 2 refrigerant circuits High efficiency even at part load Heat exchangers optimised to benefit from the excellent heat transfer characteristics of R410A High efficiency scroll compressors Axial fans with low sound level Solid construction with polyester anti-corrosion painted finish Operating Limits: Cooling Mode Versionis/L - Max. water produced 18C - Max. external air temperature 42C Version A/E - Max. water produced 18C - Max. external air temperature 46C

- 2 COOLING CIRCUITS - PUMP ASSEMBLY OPTION - PUMP ASSEMBLY AND BUFFER TANK OPTION

Versions available: Compact cooling only (sizes 500-700) L Compact low noise cooling only (sizes 280-700) A High efficiency cooling only (sizes 500-700) E H igh efficiency low noise cooling  only (sizes 280-700) C Condensing unit Fan unit (selected in unit configurator): - Standard - M High static pressure - J Inverter Pump assembly and buffer tank options complete with water filter, flow switch, expansion tank, charging point, and anti-freeze electric heater Microprocessor control system: -  Control from the entering water temperature, with the possibility of selecting control

of the leaving water temperature -  Summer condensation control with 0-10V modulating signal depending on pressure, compensated according to the outside air temperature (with DCPX accessory) - A utomatic rotation of compressors and pumps based on operating hours - Load limiting safety control - Low and high pressure transducers (for sizes 280-350 the TP3 accessory is available) - Automatic reset of alarms before tripping - Display in 4 languages - Alarm history

Accessories
AERSET: The AERSET accessory allows the automatic compensation of the operating setpoint of the unit to which it is connected, based on a 0-10V MODBUS input signal. Mandatory accessory: AER485 or MODU485A AER485: RS-485 interface for supervision systems with MODBUS protocol. VT: set of four anti-vibration mounts, to be fitted below the unit base. DCPX: Low ambient device for cooling operation below 10 C down to -10 C. Pressure transducers read the condensing pressure and the electronic controller varies fan speed to maintain adequate pressure for correct unit operation. It also allows a correct operation by heating with external temperatures above 30 C and up to 42 C. DRE: Soft starter (current reduction of about 30% for single circuit units, 26% for two circuit units, 22% for three circuit units). Only available for 400V-3-phase power supply. Factory fitted only. GP: Protection grille protects the external coil from accidental damage. PGS: Daily/Weekly Programmer. Allows two daily time-clock programmes (two switch on/ off cycles) and different programmes for each day of the week. RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted only. AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; DUALCHILLER: Simplified control system to switch on/off and control two chillers in a single system (using Aermec GR3 command), as if they were a single unit. MULTICHILLER: Control system for multiple parallel installed constant flow chillers providing individual chiller on/off and control capability. TRX1: Metal cap that replaces the plastic cap, mounted as shipping protection, for immersion heater holes in the buffer tank. PRM1: FACTORY FITTED ACCESSORY. A manual reset pressure switch wired in series with the existing high pressure switch installed on the compressor discharge line. TP3: High pressure transducer linked to the controller generates a pre-alarm in the case of high operating pressure (only for sizes 280-350). COMPATIBILITY with the VMF SYSTEM For more information on the system refer to the manual.

152

Mod. NRL AERSET AER485 DUALCHILLER MULTICHILLER PGS AERWEB300 TRX1 VT (00-P1-P2-P3-P4) VT (01-02-03-04-05-06-07-08-09-10) (1)DCPX

(1) DCPX (version with high static pressure fan) DRE GP RIF PRM1 TP3

Vers. All All All All All All All -L A-E -L A-E L A E L A E All -L A-E All All All

280 17 17 13 13 56 56 60 61 281 3 3 50

Accessory compatibility 300 330 350 17 17 17 17 17 17 13 13 13 13 13 13 56 56 56 56 57 57 60 60 61 61 61 61 301 331 351 3 3 3 4 4 4 50 50 51

500 13 13 10 10 64 standard 64 standard 64 standard 64 standard 501 2 (x2) 2 (x2) 52 standard

550 13 13 10 10 64 standard 64 standard 64 standard 64 standard 551 2 (x2) 2 (x2) 52 standard

600 13 13 10 10 64 standard 64 standard 64 standard 64 standard 601 2 (x2) 2 (x2) 53 standard

650 13 13 10 10 64 standard 64 standard 64 standard 64 standard 651 2 (x2) 2 (x2) 53 standard

700 13 22 10 22 64 standard 64 standard 64 standard 65 standard 701 2 (x2) 2 (x3) 53 standard

Note: Sizes 280,300,330,350 are only available in versions L - E. (1) Accessory DCPX includes: DCPX + TP3

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 | | | | | | | | | | Code | | Model | Version | Fan | Hydronic | | | | | Kit Size Expansion valve Heat recovery Coil Power supply Fan: - Standard M - High static pressure (sizes 280-700) J - Inverter (sizes 500-700) Power supply: - 400V 3N~ 50Hz with circuit breakers 1 - 220V 3~ 50Hz with circuit breakers Integrated hydronic module: 00 - without pump or buffer tank 01 - single low head pump and buffer tank 02 - single and standby low head pump and buffer tank 03 - single high head pump and buffer tank 04 - single and standby high head pump and buffer tank 05 - single low head pump and buffer tank (with holes for immersion heaters) 06 - single and standby low head pump and buffer tank (with holes for immersion heaters) 07 - single high head pump and buffer tank (with holes for immersion heaters) 08 - single and standby high head pump and buffer tank (with holes for immersion heaters) 09 - double hydraulic circuit 10 - double hydraulic circuit with immersion heater P1 - single low head pump without buffer tank P2 - single and standby low head pump without buffer tank P3 - single high head pump without buffer tank P4 - single and standby high head pump without buffer tank

Configuration fields:

Code: NRL Size: 0280, 0300, 0330, 0350, 0500, 0550, 0600, 0650, 0700 Expansion valve: - Standard thermostatic expansion valve for water temperature down to +4 C Y - Thermostatic expansion valve for low liquid temperature down to -6 C X - Electronic thermostatic valve, max. temp. of water produced: +4C (for lower temperatures please contact us) Model: - Cooling only C - Condensing unit Heat recovery - Without heat recovery D - With partial heat recovery (desuperheater) T - With total heat recovery Version: - Compact L - Compact low noise A - High efficiency E - High efficiency low noise Coil: - Aluminium R - Copper S - Tinned copper V - Coated aluminium

Attention: options D - T - C are not compatible with option Y the standard options are shown by the symbol

153

Technical Data
Mod. NRL Cooling capacity (kW) Vers. L A E L A E L A E L A E L A E L A E L A E All All All All L A E L A E All All All L A E L A E All L A E L A E 0280 53 57 20,68 17,16 9116 9804 51 43 2,54 3,30 3,01 3,75 36 30 46 155 2/2 14200 22000 4 6 0300 63 65 23,00 19,76 10836 11180 46 39 2,72 3,27 3,22 3,72 40 34 53 184 2/2 14200 22000 4 6 0330 68 74 26,57 22,17 11696 12728 54 35 2,54 3,32 3,01 3,80 0350 80 83 28,94 25,57 13932 14276 55 44 2,78 3,23 3,29 3,68 0500 96 87 97 90 35,39 38,98 30,72 33,54 16684 14964 16856 15480 53 43 44 37 2,72 2,22 3,17 2,67 3,28 3,27 3,68 3,65 0550 102 92 103 95 38,86 43,04 34,79 37,19 17716 15996 17888 16340 59 48 49 41 2,63 2,15 2,97 2,54 3,17 3,17 3,45 3,43 0600 125 112 128 116 46,70 51,54 40,83 44,89 21672 19436 22188 20124 64 51 54 44 2,68 2,18 3,14 2,59 3,66 3,66 4,07 3,97 0650 136 126 142 128 54,72 58,30 45,44 52,28 23564 21844 24596 22188 61 52 60 49 2,49 2,17 3,13 2,45 3,42 3,42 4,04 3,95 88 99 77 89 112 243 4/2 34600 29400 32600 22800 2 2 2 2 0700 155 143 162 149 61,02 65,67 53,29 57,45 26832 24768 28036 25800 74 63 68 58 2,54 2,18 3,04 2,60 3,48 3,48 3,93 3,83 100 111 90 97 122 261 4/2 33600 28600 50000 32500 2 2 3 3

Total power input

(kW)

Water flow rate

(l/h)

Total pressure drop ENEGY INDEX EER

(kPa)

(W/W)

ESEER POWER SUPPLY Power supply Total input current Maximum current (FLA) Starting current (LRA) Compressor type Compressor / circuit Fan type Air flow

(W/W)

(A) (A) (A)

(m/h)

Fan quantity

(n)

Evaporator Hydraulic connection (VICTAULIC) Hydraulic connection () dimension HYDRONIC KIT Useful head low pump cooling mode Useful head high pump cooling mode Buffer tank capacity SOUND DATA Sound power (kPa)

400V 3N~ 50Hz with thermomagnetic switches 63 67 81 44 51 70 75 90 55 60 71 37 45 60 64 78 58 63 76 81 100 190 200 214 220 232 Scroll 2/2 2/2 3/2 3/2 4/2 Axial 34600 34600 34600 14200 20200 28400 28700 27700 34100 34100 32600 27000 27000 21100 22200 21800 2 2 2 4 6 2 2 2 2 2 2 8 8 2 2 2 Plates Victaulic 2 96 83 135 122 300 74 75 42 43 2 89 85 129 125 300 75 76 43 44 2 123 123 121 135 162 161 160 173 500 82 77 82 74 50 45 50 42 2 111 111 109 126 150 149 148 164 500 82 77 82 74 50 45 50 42 2 91 91 85 107 184 184 179 200 500 82 77 82 74 50 45 50 42

2 104 94 143 133 300 73 74 41 42

2 106 102 145 141 300 73 74 41 42

2 83 83 71 98 177 176 166 191 500 83 78 83 75 51 46 51 43

2 91 91 76 103 146 145 132 158 500 83 78 85 77 51 46 53 45

(kPa) l

dB(A)

Sound pressure

dB(A)

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011

COOLING Evaporator water inlet 12C Evaporator water outlet 7C External air temperature 35 C t 5C SOUND PRESSURE Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

SOUND POWER Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

154

Technical Data Version C


Mod. NRL C Cooling capacity U.M. (kW) Vers. L A E L A E L A E All All L A E L A E L A E /L A/E 0280 27,5+27,5 29,5+29,5 20,48 16,95 2,67 3,46 46 155 36,3 35,3 73 74 41 42 655 662 0300 37,0+28,0 38,0+29,0 22,80 19,57 2,85 3,42 53 184 40,4 39,4 73 74 41 42 660 724 0330 35,0+35,0 38,0+38,0 26,33 22,00 2,66 3,47 58 190 44,4 43,4 74 75 42 43 664 730 0350 41,5+41,5 42,5+42,5 28,66 25,33 2,91 3,38 63 200 51,5 49,4 75 76 43 44 677 736 0500 57,0+43,0 51,0+39,0 57,5+43,5 53,0+40,0 35,11 38,85 30,47 33,40 2,85 2,31 3,31 2,78 76 214 63,6 60,8 55,5 70,5 82 77 82 74 50 45 50 42 837 918 0550 65,0+41,0 58,0+38,0 65,5+41,5 60,0+38,0 38,54 42,88 34,51 37,03 2,75 2,23 3,10 2,64 81 220 67,6 75,2 60,5 64,9 82 77 82 74 50 45 50 42 841 922 0600 65,0+65,0 58,0+58,0 66,5+66,5 60,5+60,5 46,31 51,36 40,46 44,70 2,80 2,27 3,28 2,70 100 232 81,7 90,7 71,5 78,9 82 77 82 74 50 45 50 42 931 1098 0650 70,5+70,5 65,5+65,5 73,5+73,5 66,5+66,5 54,39 58,12 45,00 52,06 2,59 2,25 3,27 2,55 112 243 88,8 99,9 77,7 89,9 83 78 83 75 51 46 51 43 939 1105 0700 80,5+80,5 74,0+74,0 84,0+84,0 77,5+77,5 60,54 65,38 52,77 57,11 2,65 2,27 3,18 2,71 122 261 100,9 112,0 90,9 97,9 83 78 85 77 51 46 53 45 1047 1264

Total power input

(kW)

EER Maximum current (FLA) Starting current (LRA) Input current

(W/W) (A) (A) (A)

Sound power

dB(A)

Sound pressure Weight empty

dB(A) Kg

COOLING Evaporating temperature External air temperature t

5 C; 35 C; 5 C.

SOUND POWER Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

SOUND PRESSURE Sound pressure in free field, at 10 m distance A from the external surface of the unit (in accordance with UNI EN ISO 3744)

C B

Dimensions (mm)
NRL 0280-0300-0330 L NRL 0350 L

NRL 0500-0550-0600-0650-0700 /L

A A

A A

C B B

C B

C B

C C B C B B

C B

C B B B

NRL 0280 E

NRL 0300-0330-0350 E

NRL 0500-0550-0600-0650 A/E

NRL 0700 A/E

A AA

A AA A A

C C C

B B B

C C B

C C B B C B

C B B B

C B B

Length Weight empty

(mm) (kg)

C C Note: Sizes 280,300,330,350 are only in versions L - E. B available B

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

155

Cod.: SNRLUY.07 / 1301

Mod. NRL Height Width AA

(mm) (mm)

A B

Vers. All All -L A-E -L A-E

0280 1606 1100 2450 2450 675 686

0300 1606 1100 2450 2950 684 751

0330 1606 1100 2450 2950 688 761

0350 1606 1100 2450 2950 704 767

0500 1875 1100 2950 2950 868 955

0550 1875 1100 2950 2950 872 959

0600 1875 1100 2950 2950 968 1142

0650 1875 1100 2950 2950 983 1155

0700 1875 1100 2950 3950 1091 1323

NRL
0280/0700 heat pump

Air-cooled heat pumps Axial fans Cooling capacity from 51 kW to 149 kW Heating capacity from 58 kW to 172 kW

R410A
Aermec participate in the EUROVENT program:LCP/A/P/C the products are present on the site www.eurovent-certification.com

COMPACT VERSION LOW NOISE COMPACT VERSION HIGH EFFICIENCY VERSION LOW NOISE HIGH EFFICIENCY VERSION
Characteristics
Available in 9 sizes Refrigerant R410A 2 refrigerant circuits High efficiency even at part load Heat exchangers optimised to benefit from the excellent heat transfer characteristics of R410A High efficiency scroll compressors Axial fans with low sound level Solid construction with polyester anti-corrosion painted finish Operating Limits:
Heating mode Versions H/HL - Max. water produced 50C - Max. external air temperature 30C (42C with accessory DCPX) Versions HA/HE - Max. water produced 55C - Max. external air temperature 30C (42C with accessory DCPX)

- 2 REFRIGERANT CIRCUITS - PUMP ASSEMBLY OPTION - PUMP ASSEMBLY AND BUFFER TANK OPTION

Cooling mode Versions H/HL - Max. water produced 18C - Max. external air temperature 30C 42C Versions HA/HE - Max. water produced 18C - Max. external air temperature 46C

Versions available: H Standard compact heat pump HL Low noise compact heat pump HA High efficiency heat pump HE High efficiency low noise heat pump Fan type (selected in unit configurator): - Standard - J Inverter Pump assembly and buffer tank options complete with water filter, flow switch, expansion tank, charging point, and antifreeze electric heater Microprocessor control system: -  Control from the entering water tempera-

ture, with the possibility of selecting control of the leaving water temperature. - Condensing control in summer with a 0-10 V modulating signal based on pressure and compensated for external air temperature (with DCPX accessory) - E vaporating control in summer for heat pump operation (with DCPX accessory) - Intelligent defrost control on drop of pressure - Automatic rotation of compressors and pumps based on operating hours - Load limiting safety control - Low and high pressure transducers (standard for all units) - Automatic reset of alarms before tripping - Display in 4 languages - Alarm history

Accessories
AERSET: The AERSET accessory allows the automatic compensation of the operating setpoint of the unit to which it is connected, based on a 0-10V MODBUS input signal. Mandatory accessory: AER485 or MODU485A AER485: RS-485 interface for supervision systems with MODBUS protocol. VT: set of four anti-vibration mounts, to be fitted below the unit base. DCPX: Low ambient device for cooling operation below 10 C down to -10 C. Pressure transducers read the condensing pressure and the electronic controller varies fan speed to maintain adequate pressure for correct unit operation. It also allows a correct operation by heating with external temperatures above 30 C and up to 42 C. DRE: Soft starter (current reduction of about 30% for single circuit units, 26% for two circuit units, 22% for three circuit units). Only available for 400V-3-phase power supply. Factory fitted only. GP: Protection grille protects the external coil from accidental damage. PGS: Daily/Weekly Programmer. Allows two daily time-clock programmes (two switch on/ off cycles) and different programmes for each day of the week. RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted only. AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; DUALCHILLER: Simplified control system to switch on/off and control two chillers in a single system (using Aermec GR3 command), as if they were a single unit. MULTICHILLER: Control system for multiple parallel installed constant flow chillers providing individual chiller on/off and control capability. TRX1: Metal cap that replaces the plastic cap, mounted as shipping protection, for immersion heater holes in the buffer tank. PRM1: FACTORY FITTED ACCESSORY. A manual reset pressure switch wired in series with the existing high pressure switch installed on the compressor discharge line. TP3: As standard COMPATIBILITY with the VMF SYSTEM For more information on the system refer to the manual.

156

Mod. NRL AERSET AER485 DUALCHILLER MULTICHILLER PGS AERWEB300 TRX1 VT (00-P1-P2-P3-P4)

VT (01-02-03-04-0506-07-08-09-10)

DCPX

DCPX vers. with high static pressure fans (*) DRE GP RIF PRM1

Vers. All All All All All All All H HL HA HE H HL HA HE H HL HA HE H HL HA HE All H HL HA HE All All

0280 17 17 13 13 58 58 63 63 281 3 3 50

Accessory compatibility 0300 0330 0350 17 17 17 17 17 17 13 13 13 13 13 13 58 58 58 58 59 59 63 63 63 63 63 63 301 331 351 3 3 3 4 4 4 50 50 51

0500 13 13 13 13 10 10 10 10 64 standard 64 standard 501 2 (x2) 2 (x2) 2 (x2) 2 (x2) 52

0550 13 13 13 13 10 10 10 10 64 standard 64 standard 551 2 (x2) 2 (x2) 2 (x2) 2 (x2) 52

0600 13 13 13 13 10 10 10 10 64 standard 64 standard 601 2 (x2) 2 (x2) 2 (x2) 2 (x2) 53

0650 13 13 13 13 10 10 10 10 64 standard 64 standard 651 2 (x2) 2 (x2) 2 (x2) 2 (x2) 53

0700 13 13 22 22 10 10 22 22 64 standard 65 standard 701 2 (x2) 2 (x2) 2 (x3) 2 (x3) 53

(*) DCPX not necessary for units with high static pressure fans (sizes 500 to 700). Fans are already fitted with speed controller.

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 | | | | | | | | | | Code | | Model | Version | Fan | Hydronic | | | | | Kit Size Expansion valve Heat recovery Coil Power supply Code: NRL Size: 0280, 0300, 0330, 0350, 0500, 0550, 0600, 0650, 0700 Expansion valve: - Standard thermostatic expansion valve for water temperature down to +4 C X - Electronic thermostatic valve, max. temp. of water produced: +4C ( for lower temperatures please contact us) Model: H - Heat pump Heat recovery - Without heat recovery D - With partial heat recovery (desuperheater) T - With total heat recovery) Version: - Standard compact L - Compact low noise A - High efficiency E - High efficiency low noise Coil: - Aluminium R - Copper S - Tinned copper V - Coated aluminium Fan: - Standard M - High static pressure (sizes 280-350) J - Inverter (sizes 500-700) Power supply: - 400V 3N~ 50Hz with circuit breakers 1 - 220V 3~ 50Hz with circuit breakers Integrated hydronic module: 00 - without pump or buffer tank 01 - single low head pump and buffer tank 02 - single and standby low head pump and buffer tank 03 - single high head pump and buffer tank 04 - single and standby high head pump and buffer tank 05 - single low head pump and buffer tank (with holes for immersion heaters) 06 - single and standby low head pump and buffer tank (with holes for immersion heaters) 07 - single high head pump and buffer tank (with holes for immersion heaters) 08 - single and standby high head pump and buffer tank (with holes for immersion heaters) 09 - double hydraulic circuit 10 - double hydraulic circuit with immersion heater P1 - single low head pump without buffer tank P2 - single and standby low head pump without buffer tank P3 - single high head pump without buffer tank P4 - single and standby high head pump without buffer tank

Attention: the standard options are shown by the symbol the configurations XD and XT are not available (only for liquid temperatures below +4C )

157

Technical Data
Mod. NRL Cooling capacity U.M. (kW) Vers. H HL HA HE H HL HA HE H HL HA HE H HL HA HE H HL HA HE H HL HA HE H HL HA HE H HL HA HE H HL HA HE H HL HA HE H HL HA HE All H HL HA HE H HL HA HE All All All All All H HL HA HE H HL HA HE H HL HA HE All All All 0280 51 53 20,45 18,10 8772 9116 47 20 58 59 19,06 17,55 9976 10148 61 25 2,48 2,92 3,02 3,85 3,07 3,38 36 30 33 35 46 155 2/2 14000 20000 14000 20000 4 6 21/2 0300 61 62 22,87 20,27 10492 10664 43 27 68 69 21,77 20,64 11696 11868 54 34 2,65 3,04 3,23 3,77 3,15 3,36 40 34 38 39 53 184 2/2 20000 26000 20000 26000 6 8 21/2 0330 66 69 26,64 23,27 11352 11868 51 23 76 76 24,87 22,82 12900 13072 66 28 2,46 2,95 3,02 3,85 3,04 3,34 0350 73 77 31,44 26,92 12556 13244 45 27 83 86 28,35 26,20 14104 14792 56 34 2,31 2,85 3,31 3,73 2,91 3,30 0500 89 83 94 90 36,91 40,13 30,82 33,48 15480 14276 16168 15480 46 39 33 30 98 100 104 104 33,81 33,81 31,71 31,71 16684 17028 17716 17716 55 55 40 40 2,42 2,06 3,04 2,68 3,30 3,28 3,71 3,67 2,89 2,95 3,26 3,26 0550 94 89 100 95 41,06 43,40 34,06 36,81 16340 15480 17200 16340 50 45 36 32 104 107 111 111 36,69 36,70 34,37 34,37 17716 18232 18920 18920 62 62 44 44 2,30 2,06 2,92 2,57 3,19 3,18 3,48 3,45 2,83 2,91 3,22 3,22 0600 114 109 121 114 49,76 52,41 41,53 45,46 19780 18920 20984 19608 53 49 36 31 127 130 136 136 43,93 43,94 40,75 40,75 21672 22188 23220 23220 67 67 44 44 2,30 2,09 2,92 2,50 3,69 3,66 4,13 4,03 2,89 2,95 3,33 3,33 0650 133 123 137 127 54,08 58,97 48,45 53,26 23048 21328 23736 22016 58 50 43 37 138 151 153 153 48,93 48,98 45,69 45,69 23564 25800 26144 26144 73 73 52 52 2,46 2,09 2,83 2,39 3,42 3,42 4,09 3,99 2,82 3,08 3,34 3,34 88 99 77 89 82 82 91 112 243 4/2 37500 27400 36500 22400 37500 37500 36500 36500 2 2 2 2 21/2 0700 144 139 149 142 63,78 66,43 52,05 58,49 24940 24080 25800 24596 64 60 49 45 157 166 172 172 56,22 56,28 53,08 53,08 26832 28380 29412 29412 83 83 64 64 2,26 2,10 2,87 2,43 3,50 3,48 3,98 3,87 2,79 2,95 3,24 3,24 100 111 90 97 95 88 99 122 261 4/2 37500 28100 58000 31900 37500 37500 58000 58000 2 2 3 3 21/2

Total power input

(kW)

Water flow rate

(l/h)

Total pressure drop

(kPa)

Heating capacity

(kW)

Total power input

(kW)

Water flow rate

(l/h)

Total pressure drop ENEGY INDEX EER

(kPa)

(W/W)

ESEER

(W/W)

COP POWER SUPPLY Power supply Total input current cooling mode Total input current heating mode Maximum current (FLA) Starting current (LRA) Compressor type Compressor / circuit Fan type Air flow (cooling) Air flow (heating)

(W/W)

(A)

(A) (A) (A) n/n

(m/h)

(m/h)

Fan quantity Evaporator Hydraulic connection Hydraulic connection dimension

(n)

()

400V 3N~ 50Hz with thermomagnetic switches 63 67 81 44 51 70 75 90 55 60 71 37 45 60 64 78 60 63 76 41 50 55 59 72 43 49 60 64 79 58 63 76 81 100 190 200 214 220 232 Scroll 2/2 2/2 3/2 3/2 4/2 Axial 39400 39400 39400 20000 20000 28400 28700 28700 37000 37000 36500 26000 26000 20200 21100 21400 39400 39400 39400 20000 20000 39400 39400 39400 37000 37000 36500 26000 26000 37000 37000 36500 2 2 2 6 6 2 2 2 2 2 2 8 8 2 2 2 Plates Victaulic 21/2 21/2 21/2 21/2 21/2

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011

COOLING Evaporator water inlet 12C Evaporator water outlet 7C External air temperature 35 C t 5C

HEATING: Evaporator water inlet 40C External air temperature 7C B.S. / 6C B.U. Evaporator water outlet 45C t 5C

158

Mod. NRL HYDRONIC KIT Useful head low pump cooling mode Useful head high pump cooling mode Useful head low pump heating mode Useful head high pump heating mode Buffer tank capacity SOUND DATA Sound power

U.M.

Vers. H HL HA HE H HL HA HE H HL HA HE H HL HA HE All H HL HA HE H HL HA HE

0280 105 104 147 143 102 94 142 133 300 73 74 41 42

0300 107 108 152 147 104 98 143 137 300 74 75 42 43

0330 97 94 144 133 93 83 132 123 300 74 75 42 43

0350 93 97 144 136 88 84 128 124 300 75 76 43 44

0500 127 131 128 135 191 191 167 173 123 122 117 117 162 160 156 156 500 82 77 82 74 50 45 50 42

0550 116 120 117 126 183 183 155 164 111 109 114 102 150 148 153 142 500 82 77 82 74 50 45 50 42

0600 100 104 98 113 234 234 192 205 91 88 91 79 184 182 185 173 500 82 77 82 74 50 45 50 42

0650 86 95 81 99 236 236 176 193 83 69 71 59 177 165 167 155 500 83 78 83 75 51 46 51 43

0700 103 108 103 117 223 223 158 171 91 80 63 63 146 136 122 122 500 83 78 85 77 51 46 53 45

(kPa)

(kPa)

(kPa)

(kPa) (l)

dB(A)

Sound pressure

dB(A)

SOUND POWER Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

SOUND PRESSURE Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).

C B

Dimensions (mm)
NRL 0280-0300-0330 H/HL NRL 0350 H/HL

NRL 0500-0550-0600-0650-0700 H/HL

A A

A A

C B B

C B

C B

C B

CC B B

C B B B

NRL 0280 HA/HE

NRL 0300-0330-0350 HA/HE

NRL 0500-0550-0600-0650 HA/HE

NRL 0700 HA/HE

A AA

A AA

A A A

CC

C B B B B

C C

C B B

C B

C B B B

C B B

A AC Length

(mm) kg

Weight empty

Note: C C Sizes 280,300,330,350 are only available in versions HL - HE.


B B

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

159

Cod.: SNRLHUY.07 / 1301

Mod. NRL Height A Width B

U.M. (mm) (mm)

Vers. All All H - HL HA - HE H - HL HA - HE

0280 1606 1100 2450 2450 713 730

0300 1606 1100 2450 2950 724 795

0330 1606 1100 2450 2950 731 805

0350 1606 1100 2450 2950 740 811

0500 1875 1100 2950 2950 913 1099

0550 1875 1100 2950 2950 917 1103

0600 1875 1100 2950 2950 1016 1204

0650 1875 1100 2950 2950 1130 1212

0700 1875 1100 2950 3950 1142 1390

NRL
0750/1800 cooling only

Air cooled chillers with axial fans Cooling capacity from 174 kW to 469 kW

R410A
Aermec adheres to the EUROVENT Certification programme up to 600kW cooling. The products concerned appear in the EUROVENT Certified products guide.

HIGH EFFICIENCY VERSION LOW NOISE HIGH EFFICIENCY VERSION COMPACT VERSION LOW NOISE COMPACT VERSION
Characteristics
Available in 9 sizes Refrigerant R410A 2 refrigerant circuits High efficiency even at part load Heat exchangers optimised to benefit from the excellent heat transfer characteristics of R410A High efficiency scroll compressors Axial fans with low sound level Solid construction with polyester anti-corrosion painted finish Operating limits in cooling up to 46 C ambient - Maximum leaving water temperature 18 C Versions available: Compact cooling only L Compact low noise cooling only A High efficiency cooling only

- 2 REFRIGERANT CIRCUITS - PUMP ASSEMBLY OPTION - PUMP ASSEMBLY AND TANK OPTION

E  High efficiency low noise cooling only C Condensing unit Expansion valve (selected in unit configurator): () standard thermostatic expansion valve (Y)  thermostatic expansion valve for low liquid temperature down to -6 C (X)  electronic expansion valve, also for low liquid temperature (down to -6 C) Fan unit (selected in unit configurator): - Standard - M High static pressure - J Inverter Pump assembly and buffer tank options complete with water filter, flow switch, expansion tank, charging point, and anti-freeze electric heater Microprocessor control system:

-  Control from the entering water temperature, with the possibility of selecting control of the leaving water temperature -  Summer condensation control with 0-10V modulating signal depending on pressure, compensated according to the outside air temperature (with DCPX accessory) - A utomatic rotation of compressors and pumps based on operating hours (manual rotation sizes 1400 to 1800) - Load limiting safety control - Low and high pressure transducers (standard for all units) - Automatic reset of alarms before tripping - Display in 4 languages - Alarm history

Accessori
AERSET: The AERSET accessory allows the daily time-clock programmes (two switch on/ automatic compensation of the operating setoff cycles) and different programmes for each point of the unit to which it is connected, day of the week. based on a 0-10V MODBUSinput signal. RIF: Power factor correction. Connected in Mandatory accessory: AER485 or MODUparallel to the motor allowing about 10% 485A reduction of input current. Must be requested AER485: RS-485 interface for supervision sysat time of order and is available factory fitted tems with MODBUS protocol. only. AVX: spring anti-vibration mounts Select the AERWEB300: Accessory AERWEB allows AVX model from the compatibility table. remote control of a chiller through a com DCPX: Low ambient device for cooling opermon PC and an ethernet connection over a ation below 10 C down to -10 C. Pressure common browser; 4 versions available: transducers read the condensing pressure and AERWEB300-6: Web server to monitor and the electronic controller varies fan speed to remote control max. 6 units in RS485 netmaintain adequate pressure for correct unit work; operation. AERWEB300-18: Web server to monitor and DRE: Soft starter (current reduction of about remote control max. 18 units in RS485 net30% for single circuit units, 26% for two cirwork; cuit units, 22% for three circuit units). Only AERWEB300-6G: Web server to monitor and available for 400V-3-phase power supply. remote control max. 6 units in RS485 netFactory fitted only. work with integrated GPRS modem; GP: Protection grille protects the external coil AERWEB300-18G: Web server to monitor and from accidental damage. remote control max. 18 units in RS485 net PGS: Daily/Weekly Programmer. Allows two work with integrated GPRS modem; DUALCHILLER: Simplified control system to switch on/off and control two chillers in a single system (using Aermec GR3 command), as if they were a single unit. MULTICHILLER: Control system for multiple parallel installed constant flow chillers providing individual chiller on/off and control capability. TRX1: Metal cap that replaces the plastic cap, mounted as shipping protection, for immersion heater holes in the buffer tank. VT: anti-vibration mounts, to be fitted below the unit base. PRM1 and PRM2: FACTORY FITTED ACCESSORY. A manual reset pressure switch wired in series with the existing high pressure switch installed on the compressor discharge line. COMPATIBILITY with the VMF SYSTEM For more information on the system refer to the manual.

160

Accessory compatibility
Mod. NRL AERSET AER485 DUALCHILLER MULTICHILLER PGS AERWEB300 TRX1 AVX VT DCPX Vers. All All All All All All All All All L A E L A E standard -L A-E -L A-E standard 0750 23 64 standard 64 standard 65 standard 65 standard 751 10 (x3) 10 (x3) 53 53 0800 64 standard 66 standard 65 standard 66 standard 801 10 (x3) 260 87 88 0900 64 di standard 66 di standard 65 di standard 66 di standard 901 10 (x3) 260 89 90 1000 65 standard 66 standard 65 standard 66 standard 1001 10 (x4) 260 91 92 1250 65 standard 67 standard 65 standard 68 standard 1251 10 (x4) 350 91 92 1404 66 standard 67 standard 66 standard 68 standard 1404 350 350 92 92 1504 66 standard 67 standard 66 standard 68 standard 1504 350 350 92 92 1655 67 standard 68 standard 68 standard 68 standard 1655 350 500 93 93 1800 67 standard 68 standard 68 standard 68 standard 1801 350 500 94 94

DCPX M vers. con ventilatori maggiorati DRE GP RIF PRM1/PRM2

NOTE: For the selection of AVX refer to the technical manual

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 | | | | | | | | | | Code | | Model | Version | Fan | Hydronic | | | | | Kit Size Expansion valve Heat recovery Coil Power supply Code: NRL Size: 0750, 0800, 0900, 1000, 1250, 1404, 1504, 1655, 1800 Expansion valve: - Standard thermostatic expansion valve for water temperature down to +4 C Y - Thermostatic expansion valve for low liquid temperature down to -6 C X - Electronic thermostatic valve, max. temp. of water produced: +4C (for lower temperatures please contact us) Model: - Cooling only C - Condensing unit Heat recovery - Without heat recovery D - With partial heat recovery (desuperheater) T - With total heat recovery (not available with buffer tank) Version: - Compact L - Compact low noise A - High efficiency E - High efficiency low noise Coil: - Aluminium R - Copper S - Tinned copper V - Coated aluminium Fan: - Standard M - High static pressure J - Inverter Power supply: - 400V 3~ 50Hz with circuit breakers - 400V 3N~ 50Hz with circuit breakers (only NRL 0750) Integrated hydronic module: 00 - without pump or buffer tank 01 - single low head pump and buffer tank 02 - single and standby low head pump and buffer tank 03 - single high head pump and buffer tank 04 - single and standby high head pump and buffer tank 05 - single low head pump and buffer tank (with holes for immersion heaters) 06 - single and standby low head pump and buffer tank (with holes for immersion heaters) 07 - single high head pump and buffer tank (with holes for immersion heaters) 08 - single and standby high head pump and buffer tank (with holes for immersion heaters) 09 - double hydraulic circuit 10 - double hydraulic circuit with immersion heater P1 - single low head pump without buffer tank P2 - single and standby low head pump without buffer tank P3 - single high head pump without buffer tank P4 - single and standby high head pump without buffer tank

Attention: options D - T - C are not compatible with option Y the standard options are shown by the symbol Example of configuration code: NRL090000 This is an NRL unit of size 900, with standard thermostatic expansion valve, cooling only model, without heat recovery, compact version, with aluminium condenser coils, standard fans, and electrical panel for compressor motors 400V 3~ 50Hz, without pump or buffer tank.

161

Technical Data

Mod. NRL Cooling capacity

U.M. (kW)

Total power input

(kW)

Water flow rate

(l/h)

Pressure drop ENERGY INDICES EER

(kPa)

Vers. L A E L A E L A E L A E L A E L A E L A E -L A-E -L A-E All -L A-E All L A E -L A-E All All L A E L A E All All

0750 189 173 194 179 70,56 76,09 63,32 69,16 32680 29928 33540 30960 86 72 88 75 2,67 2,27 3,06 2,59 3,63 3,65 3,91 3,82 122 113 113 109 144 144 320 320 4/2 4/2 51400 42700 49000 35300 3 3 81 101 74 94 198 219 191 211 700 3"

0800 210 189 217 202 79,19 88,96 70,23 77,04 36292 32680 37496 34916 66 55 66 58 2,65 2,13 3,09 2,62 3,96 3,91 4,14 4,06 142 153 136 145 170 173 345 348 4/2 4/2 54900 38430 72800 50960 3 4 100 120 93 108 216 237 208 224 700 3"

0900 230 209 241 223 93,32 102,05 82,41 89,17 39732 36120 41624 38528 68 57 70 61 2,46 2,05 2,92 2,50 3,76 3,78 4,01 3,98 166 177 158 169 192 195 401 404 4/2 4/2 54150 40575 71500 51805 3 4 92 112 81 99 207 228 195 214 700 3"

1000 255 234 269 249 105,53 114,22 94,55 102,29 44204 40420 46612 43000 73 61 70 61 2,42 2,05 2,85 2,43 3,75 3,76 3,93 3,88

1250 301 270 320 296 122,90 135,45 107,85 116,53 52116 46612 55384 51256 80 65 73 63 2,45 1,99 2,97 2,54 3,71 3,65 4,06 4,04

1404 336 301 355 327 143,93 158,47 126,14 135,76 58136 51944 61404 56588 73 59 78 67 2,33 1,90 2,81 2,41 3,55 3,49 3,85 3,82 249 269 235 251 278 284 612 618 4/2 4/2 77000 57700 104100 75420 4 6 102 133 84 110 238 272 219 247 700 4"

1504 373 334 397 365 163,26 178,72 143,91 155,55 64500 57792 68628 63124 79 64 61 52 2,28 1,87 2,76 2,35 3,46 3,44 3,84 3,79 286 308 273 292 308 314 642 648 4/2 4/2 76000 60800 102000 76500 4 6 88 115 69 94 200 241 173 209 700 4"

1655 410 365 435 407 176,91 193,45 156,06 166,76 70864 62952 75164 70348 59 48 61 54 2,32 1,88 2,79 2,44 3,57 3,51 3,88 3,87 305 328 289 306 343 349 677 683 5/2 5/2 108300 75810 125800 91110 6 8 109 134 94 111 246 270 231 247 700 4"

1800 447 392 467 434 189,05 209,48 169,22 180,86 77228 67596 80668 74992 59 46 62 54 2,36 1,87 2,76 2,40 3,64 3,49 3,88 3,86 319 348 304 324 391 398 659 666 6/2 6/2 106200 74340 122000 91500 6 8 99 129 87 106 236 266 225 244 700 4"

(W/W)

ESEER ELECTRICAL DATA Power supply Total input current Maximum current (FLA) Starting current (LRA) Type of compressors Compressors/circuits Type of fans Fan air flow rate Number of fans Evaporator Type of hydraulic connections Useful pump head low-head Useful pump head high-head Buffer tank capacity Hydraulic connections "00" version (*)

(W/W)

(A) (A) (A)

(m3/h) (n)

(kPa)

(kPa) (l) ()

400V-3-50Hz (*) 189 208 200 226 180 196 192 211 217 261 217 267 426 529 426 535 Scroll 4/2 4/2 4/2 4/2 Axial 75800 73200 53060 51240 70200 106200 52650 74340 4 4 4 6 Plate Victaulic 91 111 110 139 78 92 97 116 204 250 225 281 189 230 211 255 700 700 3" 3"

THE POWER SUPPLY FOR SIZE 750 IS: 400V-3N-50HZ.

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011

Cooling: leaving water temperature 7 C external air temperature 35 C t = 5 K.

162

Mod. NRL Sound power

U.M. dB(A)

Sound pressure

dB(A)

Vers. L A E L A E

0750 85,0 80,0 85,0 77,0 53,0 48,0 53,0 45,0

0800 86,0 83,0 88,0 83,0 54,0 51,0 56,0 51,0

0900 86,0 83,0 88,0 83,0 54,0 51,0 56,0 51,0

1000 90,0 87,0 88,0 83,0 58,0 55,0 56,0 51,0

1250 91,0 88,0 91,0 86,0 59,0 56,0 59,0 54,0

1404 90,5 87,5 90,5 85,5 58,5 55,5 58,5 53,5

1504 90,5 87,5 90,5 85,0 58,5 55,5 58,5 53,0

1655 92,0 89,0 91,5 86,5 60,0 57,0 59,5 54,5

1800 92,0 89,0 93,5 88,5 60,0 57,0 61,5 56,5

Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Technical Data " C Version "


Mod. NRL C Cooling capacity (kW) Vers. L A E L A E L A E -L A-E -L A-E L A E L A E L A E 0750 196 179 201 185 70 76 62 69 2,8 2,37 3,22 2,7 144 144 320 320 123 134 110 121 85 80 85 77 53 48 53 45 0800 220 198 227 211 81 91 71 78 2,71 2,19 3,19 2,71 170 173 345 348 147 158 140 149 86 83 88 83 54 51 56 51 0900 241 219 252 233 95 105 83 91 2,53 2,09 3,03 2,57 192 195 401 404 172 183 163 173 86 83 88 83 54 51 56 51 1000 269 245 282 260 108 117 95 103 2,48 2,09 2,97 2,52 217 217 426 426 196 207 185 197 90 87 88 83 58 55 56 51 1250 316 283 335 311 125 139 109 118 2,52 2,03 3,08 2,64 261 267 529 535 215 234 202 216 91 88 91 86 59 56 59 54 1404 352 315 372 343 147 163 127 138 2,39 1,94 2,92 2,48 290 296 499 505 258 279 241 258 90,5 87,5 90,5 85,5 58,5 55,5 58,5 53,5 1504 391 351 415 382 166 183 145 158 2,35 1,91 2,86 2,42 319 325 528 534 297 319 281 299 90,5 87,5 90,5 85 58,5 55,5 58,5 53 1655 430 383 463 426 182 199 152 169 2,37 1,92 3,05 2,52 358 365 626 633 316 340 289 315 92 89 91,5 86,5 60 57 59,5 54,5 1800 469 410 497 454 194 216 165 184 2,42 1,9 3,02 2,47 391 398 659 666 331 361 302 333 92 89 93,5 88,5 60 57 61,5 56,5

Total power input

(kW)

EER Maximum current (FLA) Starting current (LRA) Input current

(W/W) (A) (A) (A)

Sound power

db(A)

Sound pressure

db(A)

Dimensions (mm)
NRL_0750/0800/0900 -L NRL_0750 A-E NRL_1000/1250 -L NRL_1404/1504 -L NRL_0800/0900/10000 A-E NRL_1655/1800 -L NRL_1250/1404/1505 A-E NRL_1650/1800 A-E

C B

C B

C B

C B

Mod. NRL

Height Width Length Weight empty

(mm) A (mm) B (mm) C (kg)

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

163

Code: SNRLLSUY.06 /1301

Vers. -L A-E -L A-E -L A-E L A E

750 1975 1975 1500 1500 4350 4350 1382 1382 1663 1663

800 1975 2450 1500 2200 4355 3400 1730 1740 2120 2135

900 1975 2450 1500 2200 4355 3400 1860 1870 2265 2280

1000 1975 2450 1500 2200 5355 3400 2015 2025 2410 2425

1250 1975 2450 1500 2200 5355 4250 2135 2145 2710 2725

1400 2450 2450 2200 2200 4250 4250 2765 2775 2910 2925

1500 2450 2450 2200 2200 4250 4250 2960 2970 3125 3140

1650 2450 2450 2200 2200 4250 5750 3055 3065 3620 3635

1800 2450 2450 2200 2200 4250 5750 3160 3170 3735 3750

0750/1800
heat pump

NRL
R410A

Air cooled heat pumps with axial fans Capacity from 203 to 526 kW

Aermec adheres to the EUROVENT Certification programme up to 600kW cooling. The products concerned appear in the EUROVENT Certified products guide.

HIGH EFFICIENCY VERSION LOW NOISE HIGH EFFICIENCY VERSION COMPACT VERSION LOW NOISE COMPACT VERSION
Characteristics
Available in 9 sizes Refrigerant R410A 2 refrigerant circuits High efficiency even at part load Heat exchangers optimised to benefit from the excellent heat transfer characteristics of R410A High efficiency scroll compressors Axial fans with low sound level Solid construction with polyester anti-corrosion painted finish Extended operating limits in heat pump operation: - Maximum leaving water temperature 55 C - Maximum external air temperature 30 C (42 C with fan speed controller accessory DCPX) Operating limits extended operation in heat pump. Version H - HL - Max water at 50 C produced - Max air temperature 30 C (42 C with acces-

- 2 REFRIGERANT CIRCUITS - PUMP ASSEMBLY OPTION - PUMP ASSEMBLY AND BUFFER TANK OPTION

sory DCPX fan speed controller) Version. HA - HE - Max water at 55 C produced - Max air temperature 30 C (42 C with accessory DCPX fan speed controller) Cooling mode Version. H - HL - Max 18 C water produced - Max air temperature 42 C Version. HA - HE - Max 18 C water produced - Max air temperature 46 C Expansion valve (selected in unit configurator): - standard thermostatic expansion valve - X electronic expansion valve, also for low fluid temperature (down to -6 C) Fan type (selected in unit configurator): - Standard - J Inverter Pump assembly and buffer tank options complete with water filter, flow switch, expansion

tank, charging point, and anti-freeze electric heater Microprocessor control system: -  Control from the entering water temperature, with the possibility of selecting control of the leaving water temperature. - Condensing control in summer with a 0-10 V modulating signal based on pressure and compensated for external air temperature (with DCPX accessory) - E vaporating control in summer for heat pump operation (with DCPX accessory) - A utomatic rotation of compressors and pumps based on operating hours (manual rotation sizes 1400 to 1800) - Load limiting safety control - Low and high pressure transducers (standard for all units) - Automatic reset of alarms before tripping - Display in 4 languages - Alarm history DCPX standard on all versions silenced

Accessories
AERSET: The AERSET accessory allows the from accidental damage. automatic compensation of the operating set- PGS: Daily/Weekly Programmer. Allows two point of the unit to which it is connected, daily time-clock programmes (two switch on/ based on a 0-10V MODBUSinput signal. off cycles) and different programmes for each Mandatory accessory: AER485 or MODUday of the week. 485A RIF: Power factor correction. Connected in AER485: RS-485 interface for supervision sysparallel to the motor allowing about 10% tems with MODBUS protocol. reduction of input current. Must be requested AVX: spring anti-vibration mounts Select the at time of order and is available factory fitted AVX model from the compatibility table. only. DCPX: Low ambient device for cooling oper- AERWEB300: Accessory AERWEB allows ation below 10 C down to -10 C. Pressure remote control of a chiller through a comtransducers read the condensing pressure and mon PC and an ethernet connection over a the electronic controller varies fan speed to common browser; 4 versions available: maintain adequate pressure for correct unit AERWEB300-6: Web server to monitor and operation. Also permits correct unit operation remote control max. 6 units in RS485 netin heating mode with external air temperawork; tures above 30 C and up to 42 C. AERWEB300-18: Web server to monitor and DRE: Soft starter (about 26% with two comremote control max. 18 units in RS485 netpressors, 22% with three compressors). Only work; available for 400V-3-phase power supply. AERWEB300-6G: Web server to monitor and Factory fitted only. remote control max. 6 units in RS485 net GP: Protection grille protects the external coil work with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; DUALCHILLER: Simplified control system to switch on/off and control two chillers in a single system (using Aermec GR3 command), as if they were a single unit. MULTICHILLER: Control system for multiple parallel installed constant flow chillers providing individual chiller on/off and control capability. TRX1: Metal cap that replaces the plastic cap, mounted as shipping protection, for immersion heater holes in the buffer tank. VT: anti-vibration mounts, to be fitted below the unit base. PRM1 and PRM2 : FACTORY FITTED ACCESSORY. A manual reset pressure switch wired in series with the existing high pressure switch installed on the compressor discharge line. COMPATIBILITY with the VMF SYSTEM For more information on the system refer to the manual.

164

Accessory Compatibility
Mod. NRL AERSET AER485 DUALCHILLER MULTICHILLER PGS AERWEB300 TRX1 AVX "00" AVX "01...04" AVX (P1-P2-P3-P4) VT DCPX DCPX vers. with fans "J" DRE GP RIF PRM1/PRM2 Vers. 0750 All All All All All All All H - HL HA - HE H - HL HA - HE H - HL HA - HE All 23 H 64 HL standard HA 65 HE standard All 751 All H - HL 10 (x3) HA - HE 10 (x3) 53 H -HL 53 HA -HE All 0800 701 704 702 705 703 706 65 standard 66 standard 801 10 (x3) 260 87 88 0900 1000 1250 1404 1504 1655 1800 707 713 713 722 722 733 730 710 716 719 725 730 734 737 708 714 717 723 728 728 728 738 711 711 720 726 731 735 709 715 718 724 729 729 732 712 712 721 727 732 736 736 65 65 65 66 66 68 68 standard standard standard standard standard standard standard 66 66 68 68 68 68 68 standard standard standard standard standard standard standard NOTE: DCPX not necessary. The fans are already fitted with speed controller. 901 1001 1251 1404 1504 1655 1801 10 (x3) 10 (x4) 10 (x4) 350 350 350 350 260 260 350 350 350 500 500 89 91 91 92 92 93 94 90 92 92 92 92 93 94

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 4567 8 9 10 11 12 13 14 15 16 | | | | | | | | | | Code | | Model | Version | Fan | Hydronic | | | | | Kit Size Expansion valve Heat recovery Coil Power supply Code: NRL Size: 0750, 0800, 0900, 1000, 1250, 1404, 1504, 1655, 1800 Expansion valve: - Standard thermostatic expansion valve for water temperature down to +4 C X - Electronic thermostatic valve, max. temp. of water produced: +4C (for lower temperatures please contact us) Model: H - Heat pump Heat recovery - Without heat recovery D - With partial heat recovery (desuperheater) T - With total heat recovery (not available with buffer tank) Version: - Standard compact L - Compact low noise A - High efficiency E - High efficiency low noise Coil: - Aluminium R - Copper S - Tinned copper V - Coated aluminium Fan: - Standard J - Inverter Power supply: - 400V 3~ 50Hz with circuit breakers (only for NRL 800 up to 1800) - 400V 3N~ 50Hz with circuit breakers (only NRL 0750) Hdronic kit: 00 - without pump or buffer tank 01 - single low head pump and buffer tank 02 - single and standby low head pump and buffer tank 03 - single high head pump and buffer tank 04 - single and standby high head pump and buffer tank 05 - single low head pump and buffer tank (with holes for immersion heaters) 06 - single and standby low head pump and buffer tank (with holes for immersion heaters) 07 - single high head pump and buffer tank (with holes for immersion heaters) 08 - single and standby high head pump and buffer tank (with holes for immersion heaters) 09 - double hydraulic circuit 10 - double hydraulic circuit with immersion heater P1 - single low head pump without buffer tank P2 - single and standby low head pump without buffer tank P3 - single high head pump without buffer tank P4 - single and standby high head pump without buffer tank

Attention: the standard options are shown by the symbol the configurations XD and XT are not available (only for liquid temperatures below +4C ) Example of configuration code: NRL1000HE04 This is an NRL unit of size 1000, with standard thermostatic expansion valve, heat pump model, without heat recovery, high efficiency, with aluminium condenser coils, standard fans, and electrical panel for compressor motors 400V 3~ 50Hz, and single and standby high head pump and buffer tank.

165

Technical data
Mod. NRL Cooling capacity (kW) Vers. 0750 H 175 HL 164 HA 179 HE 174 H 71,23 HL 78,36 HA 64,22 HE 69,84 H 30272 HL 28380 HA 30960 HE 30100 H 74 HL 65 HA 64 HE 60 H 203 HA - HE 205 H - HL 66,77 HA - HE 62,69/62,39 H - HL 34572 HA - HE 35088 H - HL 96 HA - HE 82 H HL HA HE H HL HA HE H - HL HA - HE All H HL HA HE H HL HA HE H - HL HA - HE H - HL HA - HE All All All H HL HA HE H HL HA HE All All All 2,46 2,09 2,79 2,49 3,66 3,67 3,98 3,87 3,03 3,28/3,29 122 132 113 120 113 113 113 113 144 144 320 320 4/2 50200 41700 48000 34600 3 3 3 3 3" 0800 200 183 210 193 81,88 90,74 74,02 81,87 34572 31648 36292 33368 46 39 55 47 228 234 76,19 75,33 39044 40076 61 68 2,44 2,02 2,84 2,36 3,85 3,79 4,01 3,92 3,00 3,11 142 153 136 145 136 136 138 138 173 177 348 352 4/2 64500 45200 85600 59920 3 3 4 4 3" 0900 221 199 238 212 94,93 105,76 83,15 94,90 38184 34400 41108 36636 45 37 56 45 257 264 86,33 84,49 44032 45236 62 69 2,33 1,88 2,86 2,23 3,66 3,66 3,90 3,87 2,98 3,13 166 177 158 169 156 156 157 157 195 199 404 408 4/2 63750 44600 84600 59220 3 3 4 4 3" 1000 261 236 260 230 102,13 112,91 95,20 107,93 45064 40764 44892 39732 50 41 54 43 295 295 97,55 94,63 50396 50396 65 69 2,55 2,09 2,73 2,13 3,67 3,66 3,82 3,78 3,02 3,11 189 200 180 192 179 179 177 177 221 221 430 430 1250 299 264 313 283 121,42 137,05 110,56 123,23 51600 45580 54180 48848 57 45 61 51 342 346 113,05 112,03 58480 59168 78 76 2,46 1,93 2,83 2,29 3,63 3,56 3,96 3,93 3,03 3,09 1404 332 301 350 318 141,15 154,93 127,40 141,11 57276 51944 60372 54868 40 33 48 40 386 390 127,67 125,79 66048 66736 54 58 2,35 1,94 2,74 2,25 3,50 3,42 3,80 3,77 3,02 3,10 1504 366 331 386 354 160,25 175,00 144,55 159,24 63124 57104 66736 61060 40 34 49 41 429 435 142,85 141,02 73444 74476 55 60 2,28 1,89 2,67 2,22 3,44 3,39 3,72 3,66 3,00 3,08 286 308 273 292 261 261 265 282 312 320 646 654 4/2 86800 69400 122400 91800 4 4 6 6 4" 1655 421 372 435 397 167,61 188,18 152,86 169,47 72756 64156 75164 68456 47 37 54 45 470 486 157,13 155,41 80496 83248 59 66 2,51 1,98 2,85 2,34 3,45 3,39 3,74 3,72 2,99 3,13 305 328 286 306 279 279 282 282 349 357 683 691 5/2 124200 86900 168000 117600 6 6 8 8 4" 1800 452 396 470 424 180,68 205,22 163,99 183,53 78088 68284 81184 73272 46 36 54 44 505 526 168,23 165,57 86516 89956 58 66 2,50 1,93 2,87 2,31 3,53 3,37 3,71 3,74 3,00 3,17 319 348 304 324 290 290 293 293 398 406 666 674 6/2 122400 85700 165600 115920 6 6 8 8 4"

Total power input

(kW)

Water flow rate

(l/h)

Pressure drop

(kPa)

Heating capacity Total power input Water flow rate Pressure drop ENERGY INDICES EER

(kW) (kW) (l/h) (kPa)

(W/W)

ESEER COP ELECTRICAL DATA Supply Total input current in cooling mode

(W/W) (W/W)

(A)

Total input current in heating mode Maximum current (FLA) Starting current (LRA) Type of compressors Compressors/circuits Type of fans Fan air flow rate

(A) (A) (A) (n)

(m3/h)

Number of fans

(n)

Evaporator Type of hydraulic connection Hydraulic connections "00" version ()

400V-3-50Hz (*) 208 249 226 269 196 235 211 251 193 227 193 227 197 231 197 231 265 282 274 290 533 616 542 624 Scroll 4/2 4/2 4/2 Axial 85600 80800 87400 59900 56600 65500 83600 126000 124200 60610 88200 90000 4 4 4 4 4 4 4 6 6 4 6 6 Plates Victaulic 3" 3" 4"

(*) For size 075 has the power: 400V-3N-50Hz.

166

Mod. NRL HDRONIC KIT Useful pump head low-head cooling mode Useful pump head high-head cooling mode Useful pump head low-head heating mode Useful pump head high-head heating mode Buffer tank capacity SOUND DATA Sound power

U.M.

Vers. H HL HA HE H HL HA HE H HL HA HE H HL HA HE All
H HL HA HE H HL HA HE

0750 99 112 94 100 216 229 211 217 75 105 71 71 192 187 187 187 700
85,0 80,0 85,0 77,0 53,0 48,0 53,0 45,0

0800 110 126 100 117 226 243 216 233 90 116 84 84 205 200 199 199 700
88,5 85,5 88,5 83,0 56,5 53,5 56,5 51,0

0900 101 121 84 109 216 237 198 225 73 107 66 66 186 177 178 178 700
88,5 85,5 88,5 83,0 56,5 53,5 56,5 51,0

1000 86 109 87 114 199 223 200 228 63 91 63 63 173 163 173 173 700
90,5 87,5 88,5 83,5 58,5 55,5 56,5 51,0

1250 114 144 99 128 253 286 238 269 83 119 78 78 219 204 214 214 700
93,5 90,5 91,5 86,0 61,5 58,5 59,5 54,0

1404 106 133 90 119 243 272 225 257 65 101 61 61 197 176 193 193 700
91,0 88,0 91,0 85,5 59,0 56,0 59,0 53,5

1504 94 118 78 102 209 245 186 222 57 101 52 52 148 137 141 141 700
90,5 87,5 91,5 85,0 58,5 55,5 58,5 53,0

1655 103 131 94 117 239 266 231 253 82 112 71 71 219 210 209 209 700
92,0 89,0 92,0 86,5 60,0 57,0 60,0 54,5

1800 96 127 85 112 234 264 223 249 73 104 60 60 211 200 198,86 199 700
94,0 91,0 94,0 88,5 62,0 59,0 62,0 56,5

(kPa)

(kPa)

(kPa)

(kPa) (l)

db(A)

Sound pressure

db(A)

Cooling leaving water temperature 7 C external air temperature 35 C t = 5 C.

Heating leaving water temperature 45 C external air temperature 7 C db / 6 C wb t = 5 C.

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011 SOUND POWER: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. SOUND PRESSURE: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Dimensions (mm)
NRL_0750 HA-HE NRL_0750/0800/0900 H-HL NRL_1000/1250 H-HL NRL_0800/0900/1000 HA-HE NRL_1404/1504 H-HL NRL_1250/1404/1504 HA-HE 1655/1800 H-HL NRL_1655/1800 HA-HE

C B

C B

C B

C B

Mod. NRL Height Width Depth Weight empty

U.M. (mm) A (mm) B (mm) C (kg)

Vers.
H - HL HA - HE H - HL HA -HE H - HL HA - HE H HL HA HE

0750
1975 1975 1500 1500 4350 4350 1487 1487 1748 1748

0800
1975 2450 1500 2200 4355 3400 1800 1800 2150 2160

0900
1975 2450 1500 2200 4355 3400 1940 1950 2300 2310

1000
1975 2450 1500 2200 5355 3400 2170 2180 2460 2470

1250
1975 2450 1500 2200 5355 4250 2320 2320 2750 2760

1404
2450 2450 2200 2200 4250 4250 2930 2940 2990 3000

1504
2450 2450 2200 2200 4250 4250 3140 3150 3190 3200

1655
2450 2450 2200 2200 4250 5750 3220 3230 3680 3690

1800
2450 2450 2200 2200 4250 5750 3330 3340 3800 3810

Warning: the weights refer to versions without pump or buffer tank.

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

167

Cod.: SNRLLSHUY.10 / 1301

NRL

2000/3600 cooling only

Air cooled chiller with axial fans Cooling capacity from 497 kW to 994 kW

R410A
Aermec participate in the EUROVENT program:LCP/A/P/C, up to 600 kW the products are present on the site www.eurovent-certification.com * Not certified model

HIGH EFFICIENCY VERSION LOW NOISE HIGH EFFICIENCY VERSION COMPACT VERSION LOW NOISE COMPACT VERSION
Characteristics
Available in 7 sizes Refrigerant R410A 4 refrigerant circuits High efficiency even at part load Heat exchangers optimised to benefit from the excellent heat transfer characteristics of R410A High efficiency scroll compressors Axial fans with low sound level Solid construction with polyester anti-corrosion painted finish Operating limits in cooling up to 46 C ambient - Maximum leaving water temperature 18 C Versions available: Compact cooling only L Compact low noise cooling only A High efficiency cooling only E  High efficiency low noise cooling only C Condensing unit

- 4 REFRIGERANT CIRCUITS - PUMP ASSEMBLY OPTION - PUMP ASSEMBLY AND BUFFER TANK OPTION

Expansion valve (selected in unit configurator): () standard thermostatic expansion valve (Y)  thermostatic expansion valve for low liquid temperature down to -6 C (X)  electronic expansion valve Fan unit (selected in unit configurator): - Standard - M High static pressure - J Inverter Pump assembly and buffer tank options complete with water filter, flow switch, expansion tank, charging point, and anti-freeze electric heater Microprocessor control system: -  Control from the entering water temperature, with the possibility of selecting control of the leaving water temperature -  Summer condensation control with 0-10V modulating signal depending on pressure, compensated according to the outside air temperature (with DCPX accessory)

- A utomatic rotation of compressors and pumps based on operating hours (for all sizes) - Load limiting safety control - Low and high pressure transducers (standard for all units) - Automatic reset of alarms before tripping - Display in 4 languages - Alarm history

Accessories
AER485P1: RS-485 interface for supervision GP: Protection grille protects the external coil TRX1: Metal cap that replaces the plastic cap, systems with MODBUS protocol. from accidental damage. mounted as shipping protection, for immer AVX: spring anti-vibration mounts Select the PGS: Daily/Weekly Programmer. Allows two sion heater holes in the buffer tank. AVX model from the compatibility table. daily time-clock programmes (two switch on/ PRM1-PRM2: FACTORY FITTED ACCESSORY. DCPX: Low ambient device for cooling operoff cycles) and different programmes for each A manual reset pressure switch wired in ation below 10 C down to -10 C. Pressure day of the week. series with the existing high pressure switch transducers read the condensing pressure and RIF: Power factor correction. Connected in installed on the compressor discharge line. the electronic controller varies fan speed to parallel to the motor allowing about 10% maintain adequate pressure for correct unit reduction of input current. Must be requested operation. It also allows a correct operation at time of order and is available factory fitted by heating with external temperatures above only. 30 C and up to 42 C.

168

Accessory compatibility
Mod. NRL AER485P1 PGS TRX1 DCPX Vers. All All All L A E L A E -L A-E -L A-E All -L A-E -L A-E -L A-E 2000 standard 78 standard standard 78 standard 260 x 2 RIFNRL2000 767 768 769 2250 standard 79 standard standard 80 standard 260 350 RIFNRL2250 773 774 775 2500 standard 81 standard standard 82 standard 350 x 2 RIFNRL2500 779 780 781 2808 78 standard 81 standard 78 standard 82 standard 350 x 2 350 x 2 RIFNRL2808 RIFNRL2808 785 785 786 786 787 787 3008 78 standard 81 standard 78 standard 82 standard 350 x 2 350 x 2 RIFNRL3008 RIFNRL3008 791 791 792 792 793 793 3310 3600 81 81 standard standard 82 82 standard standard 82 82 standard standard 82 82 standard standard 350 x 2 350 x 2 500 x 2 500 x 2 RIFNRL3310 RIFNRL3600 RIFNRL3310 RIFNRL3600 791 791 798 798 792 792 799 799 793 793 800 800

DCPX M with high static pressure fans GP RIF PRM1/PRM2 AVX (00) AVX (01-02-03-04) AVX (P1-P2-P3-P4)

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 4567 8 9 10 11 12 13 14 | | | | | | | | | Code | | Model | Version | Fan | | | | | | Size Expansion valve Heat recovery Coil Power supply 15-16 | Integrated hydronic module

Code: NRL Size: 2000, 2250, 2500, 2808, 3008, 3310, 3600 Expansion valve: - Standard thermostatic expansion valve for water temperature down to +4 C Y - Thermostatic expansion valve for low liquid temperature down to -6 C X - Electronic thermostatic valve, max. temp. of water produced: +4C (for lower temperatures please contact us) Model: - Cooling only C - Condensing unit Heat recovery - Without heat recovery D - With partial heat recovery (desuperheater) T - With total heat recovery (not available with buffer tank) Version: - Compact L - Compact low noise A - High efficiency E - High efficiency low noise Coil: - Aluminium R - Copper S - Tinned copper V - Coated aluminium Fan: - Standard

M - High static pressure J - Inverter Power supply: - 400V 3~ 50Hz with circuit breakers Integrated hydronic module: 00 - without pump or buffer tank 01 - single low head pump and buffer tank 02 - single and standby low head pump and buffer tank 03 - single high head pump and buffer tank 04 - single and standby high head pump and buffer tank 05 - single low head pump and buffer tank (with holes for immersion heaters) 06 - single and standby low head pump and buffer tank (with holes for immersion heaters) 07 - single high head pump and buffer tank (with holes for immersion heaters) 08 - single and standby high head pump and buffer tank (with holes for immersion heaters) 09 - double hydraulic circuit 10 - double hydraulic circuit with immersion heater P1 - single low head pump without buffer tank P2 - single and standby low head pump without buffer tank P3 - single high head pump without buffer tank P4 - single and standby high head pump without buffer tank

Attention: options D - T - C are not compatible with option Y the standard options are shown by the symbol Example of configuration code: NRL200000 This is an NRL unit of size 2000, with standard thermostatic expansion valve, cooling only model, without heat recovery, compact version, with aluminium condenser coils, standard fans, and electrical panel for compressor motors 400V 3~ 50Hz, without pump or buffer tank.

169

Technical Data
Mod. NRL "" Cooling capacity U.M. (kW) Vers. L A E L A E L A E L A E L A E L A E (All) L A E -L A-E -L A-E -L A-E L A E L A E All All -L A-E L A E L A E All L A E L A E 2000 538 497 187,78 203,31 93052 85828 70,00 61 2,87 2,44 3,99 3,93 361 384 434 643 8/4 140400 105300 8 8 4 85 104 200 216 2x700 91 86,0 59 54 2250 589 545 201,12 218,57 101824 94256 73,00 63 2,98 2,50 4,25 4,02 377 403 484 752 8/4 *2500 *640 594 215,35 232,77 110768 102684 73,00 63 2,97 2,55 4,14 4,11 *2808 671 600 709 656 287,49 316,64 251,88 272,18 116100 103716 122636 113348 73 59 78,00 67 2,34 1,90 2,82 2,41 3,61 3,54 3,93 3,89 *3008 741 669 793 731 325,10 357,11 286,45 310,80 129000 115584 137084 126248 78 64 61,00 52 2,29 1,87 2,77 2,35 3,53 3,50 3,89 3,83 *3310 820 730 884 815 353,45 387,61 299,79 332,18 141728 126076 152736 140696 59 48 61,00 54 2,32 1,88 2,95 2,45 3,62 3,55 3,93 3,91 610 656 563 613 686 698 1020 1032 10 / 4 10 / 4 216600 151620 266000 192300 12 12 16 16 4 4 109 134 94 111 246 271 233 245 2x700 95,0 92,0 94,5 89,5 63,0 60,0 62,5 57,5 *3600 894 783 949 869 378,72 418,68 324,09 362,36 154456 135192 163916 149984 59 46 62,00 54 2,36 1,87 2,93 2,40 3,68 3,52 3,89 3,91 638 696 589 649 782 795 1050 1063 12/4 12/4 212400 148680 244000 183000 12 12 16 16 4 4 99 130 82 102 237 267 221 236 2x700 95,0 92,0 96,5 91,5 63,0 60,0 64,5 59,5

Total power input

(kW)

Water flow rate

(l/h)

Pressure drops ENERGY INDEX EER

(kPa)

(W/W)

ESEER POWER SUPPLY Power supply Total input current Maximum current (FLA) Starting current (LRA) Compressor type Compressor / circuit FAN TYPE Air flow

(W/W)

(A) (A) (A) (A) (n.)

(m3/h)

Fan quantity Evaporator Hydraulic connection Hydraulic connection dimension HYDRONIC KIT Useful head low pump cooling mode Useful head high pump cooling mode Buffer tank capacity SOUND DATA Sound power

(m3/h)

()

400V-3-50Hz with thermomagnetic switches 498 572 538 616 393 470 547 421 502 583 556 616 534 568 628 890 950 802 902 962 Scroll 8/4 8/4 8/4 8/4 8/4 Axial 154000 152000 115400 121600 176400 212400 208200 204000 126990 148680 150840 153000 8 8 8 8 10 12 12 12 10 12 12 12 Plates Victaulic 4 4 3/4 4 4 4 103 118 227 245 2x700 93 88 61 56 103 125 247 264 2x700 94 89,0 62 57 102 133 82 108 246 279 222 246 2x700 93,5 90,5 93,5 88,5 61,5 58,5 61,5 56,5 88 116 106 125 220 258 226 250 2x700 93,5 90,5 93,5 88,0 61,5 58,5 61,5 56

(kPa)

(kPa) n/l

dB(A)

Sound pressure

dB(A)

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011


* EUROVENT Not certified model

Performance values refer to the following conditions: Cooling: - leaving water temperature 7 C; - external air temperature 35 C; - t = 5 C.

SOUND POWER Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. SOUND PRESSURE Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

170

Technical Data
Mod. NRL Cooling capacity U.M. (kW) Vers. L A E L A E L A E -L A-E -L A-E L A E L A E L A E *2000 564 520 190 206 2,97 2,52 434 643 370 394 91 86,0 59 54 *2250 617 571 204 221 3,02 2,58 484 752 387 413 93 88 61 56 *2500 670 622 218 236 3,07 2,64 534 802 404 432 94 89,0 62 57 *2800 704 630 744 686 284 314 254 276 2,39 1,93 2,93 2,49 580 592 789 801 516 558 482 516 93,5 90,5 93,5 88,5 61,5 58,5 61,5 56,5 *3000 782 702 830 764 322 354 290 316 2,36 1,92 2,86 2,42 638 650 847 859 594 638 562 598 93,5 90,5 93,5 88,0 61,5 58,5 61,5 56 *3300 860 766 926 852 350 384 304 338 2,36 1,92 3,05 2,52 716 729 984 997 632 680 578 630 95,0 92,0 94,5 89,5 63 60 62,5 57,5 *3600 938 820 994 908 374 416 330 368 2,42 1,90 3,01 2,47 782 795 1050 1063 662 722 604 666 95,0 92,0 96,5 91,5 63 60 64,5 59,5

Total power input

(kW)

EER Maximum current (FLA) Starting current (LRA) Input current

(W/W) (A) (A) (A)

Sound power

(dBA)

Sound pressure

(dBA)

Performance values refer to the following conditions: Cooling: - leaving water temperature 7 C; - external air temperature 35 C; - t = 5 C.

SOUND POWER Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. SOUND PRESSURE Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Dimensions (mm)

Mod. NRL Height Width Length Weight empty C A B

U.M. (mm) (mm) (mm) (Kg)

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

171

Cod.: SNRLMSUY.05 / 1301

Vers. -L A-E -L A-E -L A-E -L A-E

2000 2450 2200 6400 4820

2250 2450 2200 7250 5240

2500 2450 2200 8100 5660

2800 2450 2450 2200 2200 8100 8100 5630 6060

3000 2450 2450 2200 2200 8100 8100 6020 6510

3300 2450 2450 2200 2200 8100 11100 6220 7590

3600 2450 2450 2200 2200 8100 11100 6420 7850

NRL

2000/3600 heat pump

Air cooled heat pumps with axial fans Cooling capacity from 461kW to 940kW Heating capacity from 588kW to 1050kW

R410A
Aermec participate in the EUROVENT program:LCP/A/P/C, up to 600 kW the products are present on the site www.eurovent-certification.com * Not certified model

HIGH EFFICIENCY VERSION LOW NOISE HIGH EFFICIENCY VERSION COMPACT VERSION LOW NOISE COMPACT VERSION

- 4 REFRIGERANT CIRCUITS - PUMP ASSEMBLY OPTION - PUMP ASSEMBLY AND BUFFER TANK OPTION

Characteristics
Available in 7 sizes Refrigerant R410A 4 refrigerant circuits High efficiency even at part load Heat exchangers optimised to benefit from the excellent heat transfer characteristics of R410A High efficiency scroll compressors Axial fans with low sound level Solid construction with polyester anti-corrosion painted finish Extended operating limits in heat pump operation: - Maximum leaving water temperature 55 C - Maximum external air temperature 30 C (42 C with fan speed controller accessory DCPX) Versions available: - H Standard compact heat pump - HL Low noise compact heat pump - HA High efficiency heat pump - HE High efficiency low noise heat pump Expansion valve (selected in unit configurator): - standard thermostatic expansion valve - X electronic expansion valve Fan type (selected in unit configurator): - Standard - M High static pressure - J Inverter Pump assembly and buffer tank options complete with water filter, flow switch, expansion tank, charging point, and anti-freeze electric heater Microprocessor control system: -  Control from the entering water temperature, with the possibility of selecting control of the leaving water temperature. - Condensing control in summer with a 0-10 V modulating signal based on pressure and compensated for external air temperature (with DCPX accessory) - E vaporating control in summer for heat pump operation (with DCPX accessory) - A utomatic rotation of compressors and pumps based on operating hours (for all sizes) - Load limiting safety control - Low and high pressure transducers (standard for all units) - Automatic reset of alarms before tripping - Display in 4 languages - Alarm history

Accessories
AER485P1: RS-485 interface for supervision from accidental damage. PRM1-PRM2: FACTORY FITTED ACCESSORY. systems with MODBUS protocol. PGS: Daily/Weekly Programmer. Allows two A manual reset pressure switch wired in AVX: spring anti-vibration mounts Select the daily time-clock programmes (two switch on/ series with the existing high pressure switch AVX model from the compatibility table. off cycles) and different programmes for each installed on the compressor discharge line. DCPX: Low ambient device for cooling operation day of the week. below 10 C down to -10 C. Pressure transducers RIF: Power factor correction. Connected in parread the condensing pressure and the electronic allel to the motor allowing about 10% reduction controller varies fan speed to maintain adequate of input current. Must be requested at time of pressure for correct unit operation. It also allows a order and is available factory fitted only. correct operation by heating with external tempe- TRX1: Metal cap that replaces the plastic cap, ratures above 30 C and up to 42 C. mounted as shipping protection, for immer GP: Protection grille protects the external coil sion heater holes in the buffer tank.

172

Accessory compatibility
Mod. NRL AER485P1 PGS TRX1 DCPX GP RIF PRM1/PRM2 AVX (00) AVX (01-02-03-04) AVX (P1-P2-P3-P4) Vers. All All All H HL HA HE H - HL HA - HE H - HL HA - HE All H - HL HA -HE H-HL HA - HE H - HL HA - HE 2000 4 4 4 standard 78 standard 260 x 2 RIFNRL2000 4 767 768 769 2250 4 4 4 standard 80 standard 260 350 RIFNRL2250 4 773 774 775 2500 4 4 4 standard 82 standard 350 x 2 RIFNRL2500 4 779 780 781 2808 4 4 4 78 standard 82 standard 350 x 2 350 x 2 RIFNRL2808 RIFNRL2808 4 785 785 786 786 787 787 3008 4 4 4 78 standard 82 standard 350 x 2 350 x 2 RIFNRL3008 RIFNRL3008 4 791 791 792 792 793 793 3310 4 4 4 82 standard 82 standard 350 x 2 500 x 2 RIFNRL3310 RIFNRL3310 4 791 798 792 799 793 800 3600 4 4 4 82 standard 82 standard 350 x 2 500 x 2 RIFNRL3600 RIFNRL3600 4 791 798 792 799 793 800

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 4567 8 9 10 11 12 13 14 | | | | | | | | | Code | | Model | Version | Fan | | | | | | Size Expansion valve Heat recovery Coil Power supply 15-16 | Integrated hydronic module

Code: NRL Size: 2000, 2250, 2500, 2808, 3008, 3310, 3600 Expansion valve: - Standard thermostatic expansion valve for water temperature down to +4 C X - Electronic thermostatic valve, max. temp. of water produced: +4C (for lower temperatures please contact us) Model: H - Heat pump Heat recovery - Without heat recovery D - With partial heat recovery (desuperheater) T - With total heat recovery (not available with buffer tank) Version: - Standard compact L - Compact low noise A - High efficiency E - High efficiency low noise Coil: - Aluminium R - Copper S - Tinned copper V - Coated aluminium

Fan: - Standard M - High static pressure J - Inverter Power supply: - 400V 3~ 50Hz with circuit breakers Integrated hydronic module: 00 - without pump or buffer tank 01 - single low head pump and buffer tank 02 - single and standby low head pump and buffer tank 03 - single high head pump and buffer tank 04 - single and standby high head pump and buffer tank 05 - single low head pump and buffer tank (with holes for immersion heaters) 06 - single and standby low head pump and buffer tank (with holes for immersion heaters) 07 - single high head pump and buffer tank (with holes for immersion heaters) 08 - single and standby high head pump and buffer tank (with holes for immersion heaters) 09 - double hydraulic circuit 10 - double hydraulic circuit with immersion heater P1 - single low head pump without buffer tank P2 - single and standby low head pump without buffer tank P3 - single high head pump without buffer tank P4 - single and standby high head pump without buffer tank

Attention: the standard options are shown by the symbol the configurations XD and XT are not available (only for liquid temperatures below +4C ) Example of configuration code: NRL2000HE04 This is an NRL unit of size 2000, with standard thermostatic expansion valve, heat pump model, without heat recovery, high efficiency, with aluminium condenser coils, standard fans, and electrical panel for compressor motors 400V 3~ 50Hz, and single and standby high head pump and buffer tank.

173

Technical Data
Mod. NRL Cooling capacity (kW) Vers. H HL HA HE H HL HA HE H HL HA HE H HL HA HE H - HL HA - HE H - HL HA - HE H - HL HA - HE H - HL HA - HE H HL HA HE H HL HA HE H - HL HA - HE (All) H HL HA HE H HL HA HE H-HL HA-HE H-HL HA-HE All All All H HL HA HE H-HL HA-HE All All All H - HL HA - HE 2000 518 461 191,13 215,61 89612 79636 53 43 588 187,94 100620 69 2,71 2,14 3,84 3,80 3,13 357 388 353 353 442 651 8/4 167200 121200 158400 8 2 3 2250 572 513 205,61 231,04 98900 88580 61 51 639 205,40 109392 75 2,78 2,22 3,90 3,86 3,11 379 414 374 374 495 763 8/4 209600 148800 199200 10 2 3/4 *2500 626 566 220,82 247,21 108188 97696 61 51 692 223,63 118336 75 *2808 665 601 699 637 282,06 309,61 254,52 281,99 114724 103716 120744 109908 40,00 33,00 48,00 40,00 770 780 255,01 252,23 131924 133644 54,00 58,00 *3008 732 663 772 707 320,24 350,79 287,79 317,22 126248 114380 133300 121948 40,00 34,00 49,00 41,00 858 870 285,35 280,66 147060 148952 55,00 60,00 *3310 844 743 870 792 334, 91 377,12 306,36 339,65 145684 128140 150156 136740 47,00 37,00 54,00 45,00 940 972 314,85 309,37 160992 166496 59,00 66,00 2,52 1,97 2,84 2,33 3,47 3.40 3,75 3,74 2,99 3,14 592 641 572 625 558 558 565 565 698 714 1032 1048 10/4 248400 173800 336000 235200 234600 318400 16 2 4 4 *3600 905 792 940 849 361,03 410,14 327,54 366,76 156176 136568 162368 146544 46,00 35,00 53,00 46,00 1009 1050 337,04 330,67 172860 179740 58,00 66,00 2,50 1,93 2,87 2,32 3,54 3,38 3,73 3,75 2,99 3,17 618 673 595 654 579 579 585 585 796 813 1064 1081 12/4 244800 171400 331200 231800 229200 312000 16 2 4 4

Total power input

(kW)

Water flow rate

(l/h)

Pressure drops Heating capacity Total power input Water flow rate Pressure drops ENERGY INDEX EER

(kPa) (kW) (kW) (l/h) (kPa)

(W/W)

ESEER COP Power supply Total input current (cooling) Total input current (heating) Maximum current (FLA) Starting current (LRA) Compressors tipe Compressors/circuit Fan tipe Total air flow rate in cooling mode Total air flow rate heating mode Fan quantity Evaporator Hydraulic connection Dimension of hydraulic connection V00

(W/W) (W/W) (A) (A)

(A) (A) (A) n/n

(m3/h) (m3/h) n n ()

2,36 2,29 1,94 1,89 2,84 2,75 2,68 2,29 2,26 2,23 3,52 3,45 3,44 3.40 3,98 3,82 3,74 3,95 3,78 3,68 3,02 3,01 3,09 3,09 3,10 400V - 3 - 50Hz with megnetotermic 482 551 521 594 401 469 536 441 511 582 454 522 454 522 395 462 530 395 462 530 564 624 548 580 640 898 958 816 914 974 SCROLL 8/4 8/4 8/4 Axial 174800 173600 131000 138800 252000 248400 244800 176400 180000 183600 169800 168000 240000 234600 229200 12 12 12 2 2 2 VICTAULIC 4 4 4 4 4

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011


* EUROVENT Not certified model

174

Mod. NRL Useful head low pump cooling mode Useful head high pump cooling mode Useful head low pump heating mode Useful head high pump heating mode Buffer tank capacity Sound power

U.M. (kPa)

(kPa) (kPa) (kPa) (l) dB(A)

Sound pressure

dB(A)

Vers. H HL HA HE H HL HA HE H-HL HA-HE H-HL HA-HE All H HL HA HE H HL HA HE

2000 94 118 207 233 71 181 2x700 91,5 86,0 59,5 54,0

2250 111 139 250 280 88 223 2x700 93,3 87,8 61,3 55,8

*2500 110 136 248 278 89 225 2x700 94,5 89,0 62,5 57,0

*2808 104 131 87 116 240 270 222 254 63 58 195 189 2x700 93,5 90,5 94,0 88,5 62 59 62 56,5

*3008 124 144 113 131 240 270 220 251 95 91 186 180 2x700 93,5 90,5 93,5 88,0 61,5 58,5 61,5 56,0

*3310 106 134 98 121 243 270 236 257 86 76 224 214 2x700 95,0 92,0 95,0 89,5 63,0 60,0 63,0 57,5

*3600 96 127 85 112 233 263 223 249 73 60 211 198 2x700 95,0 92,0 97,0 91,5 65,0 62,0 65,0 59,5

Performance values refer to the following conditions: Cooling - leaving water temperature 7 C; - external air temperature 35 C; - t = 5 C. Heating: - leaving water temperature 45 C; - external air temperature 7 C B.S. 6 C B.U.; - t = 5 C.

SOUND POWER Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. SOUND PRESSURE Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Dimensions (mm)

Mod. NRL Height Width Length Weight empty C A B

U.M. (mm) (mm) (mm) (kg)

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

175

Cod.: SNRLMSHUY.05 / 1301

Vers. H - HL HA - HE H - HL HA -HE H - HL HA - HE H - HL HA-HE

200 2450 2200 6400 4930

225 2450 2200 7250 5360

250 2450 2200 8100 5780

280 2450 2450 2200 2200 8100 8100 6080 6190

300 2450 2450 2200 2200 8100 8100 6490 6630

330 2450 2450 2200 2200 8100 11100 6660 7710

360 2450 2450 2200 2200 8100 11100 6880 7980

0200/0750

NRP
R410A

Multipurpose air cooled units with axial fans

DESIGNED FOR 2 AND 4-PIPE SYSTEMS FOR EXTERNAL INSTALLATION HIGH EFFICIENCY VERSION

Features
NRP is the range of multipurpose external units operating on refrigerant R410A, designed for 2 or 4-pipe systems. With just one unit simultaneous and independent requests for hot and chilled water can be accommodated all year round. Axial fans with low sound level. Extremely solid structure with anti-corrosion polyester paint. Extended operating limits in heat pump operation: - Maximum leaving water temperature 55 C. - External air temperature from -15 C to 42 C. Range: Units fitted as standard with fan speed con Refrigerant R410A. troller (DCPX), which permits operation in the 2 refrigerant circuits. winter with external temperatures down to High efficiency even at part load. 10 C, and in heating mode with external Heat exchangers optimised to benefit from temperatures up to 42 C. the excellent heat transfer characteristics of Available versions: R410A. - A High efficiency heat pump. High efficiency scroll compressors. - E High efficiency low noise heat pump. Fans: - Standard. - M High static pressure. - J Inverter. Options for integrated hydronic modules with pumps, buffer tank, water filter, flow switch, expansion tank. Microprocessor controls.

Accessories
VT: Anti-vibration mounts to be installed AER485P1: RS-485 interface for supervising AERWEB300-18G: Web server to monitor and under the base of the unit. systems with MODBUS protocol. remote control maximum 18 units on RS485 GP: Protection grille protects the external AERWEB300: The AERWEB option allows network with integrated GPRS modem. coil from accidental damage. remote control of a chiller through a stand- PGD1: Simplified remote panel. Allows con TRX1: Metal cap that replaces the plastic ard PC and an ethernet connection with a trol of basic unit functions and alarm notificacap, mounted as shipping protection, for standard browser; 4 versions available: tion. Remote mounted up to 500 m away immersion heater holes in the buffer tank. AERWEB300-6: Web server to monitor and with TWISTED PAIR SCREENED cable and DRE: Electronic soft starter which reduces remote control maximum 6 units on RS485 TCONN6J000. starting current by about 26%. Available only network; with 400V power supply. Factory fitted only. AERWEB300-18: Web server to monitor and RIF: Power factor correction. Connected in remote control maximum 18 units on RS485 parallel to the motor allowing about 10% network; reduction of input current. Must be requested AERWEB300-6G: Web server to monitor and at time of order and is available factory fitted remote control maximum 6 units on RS485 only. network with integrated GPRS modem;

176

Accessory compatibility

00 |P1- P2-P3-P4 VT 01...08 P1|R1...P4|R4 GP HA HE TRX1 all DRE all RIF all AER485P1 all AERWEB300 all PGD1 all

0200 17 13 17 GP3 281 54

0240 17 13 17 GP3 281 54

0280 17 13 17 GP3 281 50

0300 17 13 17 GP4 301 50

0330 17 13 17 GP4 331 50

0350 17 13 17 GP4 351 51

0500 13 10 13 GP2x2 GP2x2 501 52

0550 13 10 13 GP2x2 GP2x2 551 52

0600 13 10 13 GP2x2 GP2x2 601 53

0650 13 10 13 GP2x2 GP2x2 651 53

0700 22 22 22 GP2x3 GP2x3 701 53

0750 23 23 23 GP10x3 GP10x3 751 53

Choosing the unit


By appropriately combining the variety of options available, it is possible to configure every model in a manner that satisfies all specific system requirements. Configuration fields: 1 2 3 4567 8 9 10 11 12 13 14 15 16 | | | | | | | | | Code | | System type | Fan | System integrated | | | | | hydronic module | Size Version Coil Power supply Heat recovery integrated hydronic module Code: NRP Size: 0200, 0240, 0280, 0300, 0330, 0350, 0500, 0550, 0600, 0650, 0700, 0750 Version: A - High efficiency E - High efficiency low noise System type: 2 - 2-pipe system (cooling + DHW heating) 4 - 4-pipe system (cooling + heating) Coil: - Aluminium R - Copper S - Tinned copper V - Coated aluminium (epoxy paint) Fan: - Standard M - High static pressure (only sizes 0200-0350) J - High static pressure inverter (only sizes 0500-0750) Power supply: - 400V/3N/50Hz with circuit breakers 1 - 220V/3/50Hz with circuit breakers (not available for sizes 0750) System integrated hydronic module (1): 00 - without pumps or buffer tank 01 - low head pump and buffer tank 02 - low head and standby pump and buffer tank 03 - high head pump and buffer tank 04 - high head and standby pump and buffer tank 05 - low head pump and buffer tank (with holes for immersion heaters) 06 - l ow head and standby pump and buffer tank (with holes for immersion heaters) 07 - high head pump and buffer tank (with holes for immersion heaters) 08 - high head and standby pump and buffer tank (with holes for immersion heaters) P1 - only low head pump P2 - only low head and standby pump P3 - only high head pump P4 - only high head and standby pump Heat recovery integrated hydronic module (2): 00 - without pumps R1 - only low head pump R2 - only low head and standby pump R3 - only high head pump R4 - only high head and standby pump CONFIGURATION POSSIBILITY BETWEEN HYDRONIC MODULES FOR NRP 0200 0750 heat recovery hydronic module

Attention: - Sizes 0200 to 0350 only available in low noise version "E". (1) 4-pipe cooling and heating 2-pipe cooling or heating (2) 2-pipe system - can works as priority regardless of main system operation

00 01 02 03 04 05 06 07 08 P1 P2 P3 P4

00 ok ok ok ok ok ok ok ok ok ok ok ok ok

R1 ok nd nd nd nd nd nd nd nd ok ok ok ok

R2 ok nd nd nd nd nd nd nd nd ok ok ok ok

R3 ok nd nd nd nd nd nd nd nd ok ok ok ok

R4 ok nd nd nd nd nd nd nd nd ok ok ok ok

nd = not available

system hydronic module

177

Technical data 1
NRP Cooling capacity Total input power Water ow rate Pressure drop SISTEM SIDE EER u.m (kW)
Version

Heating capacity Total input power Water ow rate Pressure drop SISTEM SIDE vers. 2 pipe system Pressure drop DHW SIDE/SYSTEM SIDE* COP Cooling capacity Heating capacity Total input power Evaporator water ow rate Evaporator Pressure drop system side Recovery water ow rate Recovery water ow rate DHW SIDE/SYSTEM SIDE* Total Efciency Ratio (TER) Electrical data Power supply Total input current Maximum current (FLA) Starting current (LRA) Compressors Compressors (n/circuit) Fans Air ow rate Quantity of fans High static pressure fans (M) Static pressure available Inverter fans (J)

A E A (kW) E A (l/h) E A (kPa) E (W/W) A (W/W) E (kW) A/E (kW) A/E (l/h) A/E (kPa) (kPa) (W/W) (kW) (kW) (kW) (l/h) (kPa) (l/h) (kPa) A/E A/E A/E A/E A/E A/E A/E A/E A/E A/E

0200 43 13,8 7400 26 3,12 46 13,1 7912 31 13 3,50 45 58 13,0 7740 30 9976 20 7,92

0240 50 16,3 8600 37 3,06 53 15,3 9116 42 17 3,46 52 67 15,2 8944 40 11520 27 7,83

0280 56 18,7 9549 22 2,96 60 17,5 10236 25 21 3,41 58 75 17,5 9890 24 12900 33 7,60

0300 64 20,6 10956 29 3,10 75 22,0 12833 39 33 3,40 68 88 20,0 11696 33 15136 46 7,80

0330 68 23,0 11711 22 2,97 80 23,6 13732 31 38 3,38 73 95 22,0 12556 26 16340 54 7,64

0350 80 26,7 13776 31 3,00 84 25,3 14526 34 19 3,33 86 111 25,0 14792 36 19092 33 7,88

0500 100 95 32,0 34,8 17118 16390 37 34 3,11 2,74 106 32,1 18242 42 31 3,30 102 132 30,0 17544 39 22704 47 7,80

0550 104 99 35,5 38,5 17949 17051 39 35 2,94 2,58 112 34,5 19290 45 34 3,25 110 142 32,0 18920 43 24424 55 7,88

0600 124 116 43,6 47,9 21269 19874 37 32 2,83 2,41 137 40,6 23507 45 51 3,37 132 174 42,0 22704 42 29928 82 7,29

0650 141 131 49,8 54,9 24211 22457 48 41 2,83 2,38 152 44,9 26146 56 49 3,39 147 193 46,5 25198 52 33196 78 7,30

0700 160 153 54,3 61,1 27556 26270 56 51 2,95 2,50 173 52,8 29796 66 35 3,28 167 218 51,0 28724 61 37496 56 7,55

0750 185 179 63,5 69,6 31749 30867 67 63 2,91 2,58 205 61,4 35340 83 50 3,34 200 261 61,0 34400 78 44892 80 7,56

(W/W) A/E

(A) (A) (A)

A E A/E A/E A/E

28 36 119 2/2 20000 6 50 -

33 41 150 2/2 20000 6 50 -

38 46 155 2/2 20000 6 50 -

41 53 184 2/2 26000 8 50 -

45 58 190 2/2 26000 8 50 -

400V/3N/50Hz 55 52 63 200 scroll 3/2 Axial 37000 26000 20200 8 2 50 2/2 60 76 214

59 64 81 220 3/2 37000 21100 2 80

72 79 100 232 4/2 36500 21400 2 80

82 91 112 243 4/2 36500 22400 2 80

88 99 122 261 4/2 58000 31900 3 80

113 120 144 320 4/2 48000 34600 3 80

(m/h) A E (n) A/E (Pa)

Static pressure available (Pa) Evaporator Hydraulic connection type Hydraulic connections size () hydronic module Pumps - Useful head (calculated in cooling mode) A Low head pump (kPa) E A High head pump (kPa) E Buffer tank Capacity (l) Sound data A Sound pressure dB(A) E A Sound power dB(A) E Sound pressure Sound power

21/2

21/2

21/2

21/2

21/2

80 Plate Victaulic 21/2 21/2

21/2

21/2

21/2

21/2

132 172 300 42 74 42 74

120 160 300 42 74 42 74

135 175 300 42 74 42 74

126 165 300 43 75 43 75

128 166 300 43 75 43 75

120 159

141 147 181 186

133 140 173 180 500 50 42 82 74 50 82

124 135 211 223 500 50 42 82 74 50 82

95 114 181 200 500 51 43 83 75 51 83

113 125 177 192 500 53 45 85 77 53 85

104 110 224 231 700 53 45 85 77 53 85

300 500 COOLING MODE 50 44 42 82 76 74 HEATING MODE 44 76 50 82

dB(A)

1 2

Cooling mode: evaporator leaving water temperature 7 C external air temperature 35 C T 5K Heating mode: condenser leaving water temperature 45C evaporator air temperature 7 C db / 6 C wb T 5K

3 Cooling mode with heat recovery:

heat recovery leaving water temperature 45 C evaporator leaving water temperature 7 C T 5K Sound power: Aermec determines sound power values in accordance with ISO 9614-2, as required for Eurovent certification.

Sound Pressure: Sound pressure measured in free field conditions over a reflective plane (directivity factor Q=2) at 10 m distance from external surface of unit, in accordance with ISO 3744. *DHW SIDE/SYSTEM SIDE DHW side, production of domestic hot water, in 2-pipe systems. System side, production of hot water, in 4-pipe systems.

178

Dimensions (mm)

A A C C B
NRP 0200 0280 NRP 0300 0350

C B
NRP 0500 0650

C B
NRP 0700 0750

NRP Height (mm) Width (mm) Length (mm) Weight empty

u.m A B C (kg)

0200

0240 1606 1100 2700 790

0280 1606 1100 2700 792

0300 1606 1100 3200 862

0330 1606 1100 3200 872

0350 1606 1100 3200 894

0500 1875 1100 3280 1233

0550 1875 1100 3280 1237

0600 1875 1100 3280 1359

0650 1875 1100 3280 1378

0700 1875 1100 4280 1591

0750 1975 1500 4350 1939

A/E A/E A/E A/E

1606 1100 2700 788

Attention: weights refer to units without pumps or buffer tank.

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

179

Cod.: SNRP0200-0750UY.01 /1301

0800/1800

NRP
R410A

Multipurpose air cooled units with axial fans

DESIGNED FOR 2 AND 4-PIPE SYSTEMS FOR EXTERNAL INSTALLATION HIGH EFFICIENCY VERSION

Features
NRP is the range of multipurpose external units operating on refrigerant R410A, designed for 2 or 4-pipe systems. With just one unit simultaneous and independent requests for hot and chilled water can be accommodated all year round. Axial fans with low sound level. Extremely solid structure with anti-corrosion polyester paint. Extended operating limits in heat pump operation: - Maximum leaving water temperature 55 C. - External air temperature from -15 C to 42 C. Range: Units fitted as standard with fan speed con Refrigerant R410A. troller (DCPX), which permits operation in the 2 refrigerant circuits. winter with external temperatures down to High efficiency even at part load. 10 C, and in heating mode with external Heat exchangers optimised to benefit from temperatures up to 42 C. the excellent heat transfer characteristics of Available versions: R410A. - A High efficiency heat pump. High efficiency scroll compressors. - E High efficiency silenced heat pump. Ventilation Unit: - Standard. - J Inverter. Options for integrated hydronic modules with pumps, water filter, flow switch, expansion tank. Microprocessor controls.

Accessories
AVX: Anti-vibration mounts to be installed AERWEB300-18: Web server to monitor and RIF: Power factor correction. Connected in under the base of the unit. remote control maximum 18 units on RS485 parallel to the motor allowing about 10% GP: Protection grille protects the external network; reduction of input current. Must be requested coil from accidental damage. AERWEB300-6G: Web server to monitor and at time of order and is available factory fitted AER485P1: RS-485 interface for supervising remote control maximum 6 units on RS485 only. systems with MODBUS protocol. network with integrated GPRS modem; PGD1: Simplified remote panel. Allows control AERWEB300: The AERWEB option allows AERWEB300-18G: Web server to monitor and of basic unit functions and alarm notification. remote control of a chiller through a standremote control maximum 18 units on RS485 Remote mounted up to 500 m away with ard PC and an ethernet connection with a network with integrated GPRS modem. T W I S T E D PA I R S C R E E N E D c a b l e a n d standard browser; 4 versions available: DRE: Electronic soft starter which reduces TCONN6J000. AERWEB300-6: Web server to monitor and starting current by about 26%. Available only remote control maximum 6 units on RS485 with 400V power supply. Factory fitted only. network;

180

NRP AVX GP AER485P1 AERWEB300 DRE PGD1 RIF 00 P1-P2-P3-P4 P1|R1...P4|R4 all all all all all all

0800 704 706 706 GP260 801 88

0900 710 712 712 GP260 901 90

Accessory compatibility 1000 1250 716 719 712 721 712 721 GP260 GP350 1001 1251 92 92

1404 725 727 727 GP350 1401 93

1504 730 732 732 GP350 1501 94

1655 734 736 736 GP500 1651 94

1800 737 736 736 GP500 1801 94

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements. Configuration fields: 1 2 3 4567 8 9 10 11 12 13 14 15 16 | | | | | | | | | Code | | System type | Fan | System integrated | | | | | hydronic module | Size Version Coil Power supply Heat recovery integrated hydronic module Code: NRP Size: 0800, 0900, 1000, 1250, 1404, 1504, 1655, 1800 Version: A - High efficiency E - High efficiency low noise System type: 2 - 2-pipe system (cooling + DHW heating) 4 - 4-pipe system (cooling + heating) Coils: - Aluminium R - Copper S - Tinned copper V - Coated aluminium (epoxy paint) Fans: - Standard J - High static pressure inverter Power supply: - 400V/3N/50Hz with circuit breakers System integrated hydronic module (1): 00 - without pumps or buffer tank P1 - only low head pump P2 - only low head and standby pump P3 - only high head pump P4 - only high head and standby pump Heat recovery integrated hydronic module (2): 00 - without pumps R1 - only low head pump R2 - only low head and standby pump R3 - only high head pump R4 - only high head and standby pump

NRP

CONFIGURATION POSSIBILITY BETWEEN HYDRONIC MODULES FOR NRP 0800 1000 heat recovery hydronic module
P1 P2 P3 P4 ok ok ok ok ok R1 ok ok ok ok ok R2 na na na na na R3 ok ok ok ok ok R4 na na na na na

n.a. = not available CONFIGURATION POSSIBILITY BETWEEN HYDRONIC MODULES FOR NRP 1250 1800 heat recovery hydronic module
P1 P2 P3 P4 ok ok ok ok ok R1 ok ok ok ok ok R2 ok ok ok ok ok R3 ok ok ok ok ok R4 ok ok ok ok ok

(1) 4-pipe cooling and heating 2-pipe cooling or heating (2) 2-pipe system - can works as priority regardless of main system operation

system hydronic module

system hydronic module


NRP

181

Technical data 1
NRP Cooling capacity Total input power Water ow rate Pressure drop SISTEM SIDE EER Version A (kW) E A (kW) E A (l/h) E A (kPa) E (W/W) A (W/W) E (kW) A / E (kW) A / E (l/h) A / E u.m (kPa) (kPa) (W/W) (kW) (kW) (kW) (l/h) (kPa) (l/h) (kPa) A/E A/E A/E A/E A/E A/E A/E A/E A/E A/E 0800 218 200 72,4 80,3 37498 34477 59 50 3,01 2,50 241 73,2 41498 73 50 3,29 223 289 66,0 38356 62 49709 72 7,76 0900 243 217 82,2 94,3 41841 37289 58 47 2,96 2,30 258 79,7 44312 66 44 3,23 251 328 77,0 43172 62 56417 72 7,52 1000 260 230 88,2 100,4 44753 39609 54 43 2,95 2,29 290 87,8 49946 68 49 3,31 278 364 86,0 47817 62 62609 77 7,47 1250 323 291 107,7 120,5 55506 50044 64 54 3,00 2,41 384 114,5 66115 93 49 3,36 334 432 98,0 57449 71 74305 63 7,82 1404 365 332 121,0 134,4 62852 57122 52 43 3,02 2,47 400 119,5 68833 63 44 3,35 379 491 112,0 65189 56 84453 66 7,77 1504 402 368 135,0 149,2 69171 63288 53 44 2,98 2,47 459 137,6 78870 68 51 3,33 422 550 128,0 72585 58 94601 73 7,59 1655 441 402 145,3 161,6 75888 69115 55 46 3,04 2,49 503 153,0 86579 72 51 3,29 463 598 135,0 79637 61 102857 72 7,86 1800 477 430 155,9 175,1 81966 73977 55 45 3,06 2,46 544 164,6 93555 72 53 3,30 496 642 146,0 85313 60 110425 74 7,79

Heating capacity Total input power Water ow rate Pressure drop SISTEM SIDE vers. 2 pipe system Pressure drop DHW SIDE/SYSTEM SIDE* COP Cooling capacity Heating capacity Total input power Evaporator water ow rate Evaporator Pressure drop system side Heat recovery water ow rate Heat recovery water ow rate DHW SIDE/SYSTEM SIDE* Total Efciency Ratio (TER) Electrical data Power supply Total input current Maximum current (FLA) Starting current (LRA) Compressors Compressors (n/circuits) Fans Air ow rate Quantity of fans Inverter fans (J)

(W/W) A / E

(A) (A) (A)

A E A/E A/E A/E

136 145 173 348 4/2 85600 59920 4 50

158 169 195 404 4/2 84600 59220 4 50

180 192 217 426 4/2 83600 60610 4 50

400V/3/50Hz 196 235 211 267 535 4/2 Axial 126000 88200 6 50 plate Victaulic 251 296 505 5/2 124200 90000 6 50

273 292 325 534 6/2 122400 91800 6 50

289 306 365 633 6/2 168000 117600 8 50

304 324 398 666 6/2 165600 115920 8 50

(m/h) A E (n) A/E

Static pressure available (Pa) Evaporator Hydraulic connections type Hydraulic connections size () Hydronic module Pumps - Useful head (calculated in cooling mode) A Low head pump (kPa) E A High head pump (kPa) E Sound pressure Sound power dB(A) dB(A) A E A E

3"

3"

3"

4"

4"

4"

4"

4"

123 135 240 252 56,5 51 88,5 83 56,5 88,5

114 132 230 249 56,5 51 88,5 83 56,5 88,5

111 131 225 247 56,5 51 88,5 83,5 56,5 88,5

128 128 150 149 269 266 293 289 Cooling mode 59,5 59 54 53,5 91,5 91 86 85,5 Heating mode 59,5 91,5 59 91

125 141 246 272 58,5 53 91,5 85 58,5 91,5

106 126 241 261 60 54,5 92 86,5 60 92

95 119 232 255 62 56,5 94 88,5 62 94

Sound pressure Sound power

dB(A)

1 2 3

Cooling mode: evaporator leaving water temperature 7 C external air temperature 35 C T 5K Heating mode: condenser leaving water temperature 45C evaporator air temperature 7 C db / 6 C wb T 5K Cooling mode with heat recovery: heat recovery leaving water temperature 45 C evaporator leaving water temperature 7 C T 5K

Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

* DHW SIDE/SYSTEM SIDE DHW side, production of domestic hot water, in 2-pipe systems. System side, production of hot water, in 4-pipe systems.

182

Dimensions (mm)

B
NRP
u.m A B C (kg)

0800

0900 2450 2200 3400 2460

1000 2450 2200 3400 2640

1250 2450 2200 4250 2970

1404 2450 2200 4250 3220

1504 2450 2200 4250 3430

1655 2450 2200 5750 3950

1800 2450 2200 5750 4090

Height (mm) Width (mm) Length (mm) Weight empty

A/E A/E A/E A/E

2450 2200 3400 2270

Attention: weights refer to units without pumps or buffer tank.

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

183

Cod.: SNRP0800-1800UY.01 /1301

NRL
0280/0700
free-cooling

Air cooled chiller with axial flow fans Cooling capacity from 58 kW up to 174 kW

R410A

HIGH EFFICIENCY VERSION SILENCED HIGH EFFICIENCY VERSION VERSION WITH CIRCULATION PUMP 2 COOLING CIRCUITS
Features
Available in 9 different sizes Refrigerant R410A. 2 cooling circuits High efficiency even with partial loads Heat exchangers optimised to exploit the excellent heat transfer characteristics of the R410A High-efficiency scroll compressors Axial flow fans with reduced noise level Solid construction with polyester anticorrosion painted finish Cooling mode up to 44 C Operation modes: - Free-Cooling only: is the most economical way to use the unit. Only the fans operate in modulation of speed, the cooling power is fully recovered from the external air - mixed Free-Cooling and compressors: the cooling power recovered from the external air is integrated with the total or partial operation of the

VERSION WITH CIRCULATION PUMP AND STORAGE TANK

compressors - compressors only: the cooling capacity is provided entirely by the compressors (standard operation of a chiller) Versions available: - High efficiency - Silenced high efficiency - Glycole-free - With pumping assembly (high-head, with/ without reserve pump) - Versions with pumping assembly and 300 litre tank, complete with water filter, flow switch, expansion tank and antifreeze electric heater - Electronic thermostatic valve - Enlarged fans Microprocessor control system of the compressors and fans for the management of the three operating modes (Free-Cooling only, mixed FreeCooling and compressors and compressors only)

Display of all operating parameters in 4 languages. Simplified remote control panel with shielded cable up to 50 m. Performs the basic checks of the unit with alarm warnings. High efficiency air-water exchanger (Free-Cooling) with smooth tubes and corrugated fins Three-way valve located on the water side for water switch-over on the Free-Cooling coils High and low pressure transducers(standard for all versions) Fan speed adjustment device for low air temperature operation. Manages the cooling capacity in the Free-Cooling mode

Accessories
AER485: RS-485 interface for supervision systems with MODBUS protocol. AERSET: The AERSET accessory allows the automatic compensation of the operating setpoint of the unit to which it is connected, based on a 0-10V MODBUS input signal. Mandatory accessory: AER485 or MODU-485A VT: anti-vibration support, to be fitted below the sheet metal base of the unit. DRE: Current soft starter device (about 26% for two-circuit-units, 22% for three-circuitunits) Only available for 400V-3-phase power supply. It must be factory set GP: Protection grille, protects the external coil from accidental knocks. PGS: Daily/Weekly Programmer. Allows you to programme two time bands per day (two switch on/off cycles) and to have differentiated programming for each day of the week. RIF: Capacitor device . Connected in parallel to the motor winding. It allows to maintain a costant COSd at 0.95 and also allows an input current reduction (about 10%). It must be factory set when the unit is manufactured AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: - AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; - AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; - AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; - AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem DUALCHILLER: Simplified control system to switch on and off, and command, two chillers (using Aermec GR3 command) in a single system, as if they were a single unit. MULTICHILLER: Control system to switch the individual chillers on and off, and command them, in a system in which several units are installed in parallel, always ensuring a constant delivery to the evaporators. PRM1-PRM2: FACTORY FITTED ACCESSORY. It is a manual pressure switch electrically wired in series with the existing automatic high pressure switch on the compressor discharge pipe.

184

Mod. NRL AER485

AERSET
dualchiller multichiller PGS AERWEB300 VT DRE GP RIF PRM1-PRM2

Vers. All All All All All All 00 - P3 - P4 03 - 04 All All All All

0280 17 13 281 4 50

0300 17 13 301 4 50

Compatibility of accessories 0330 0350 17 17 13 13 331 351 4 4 50 51

0500 13 10 501 2(x2) 52

0550 13 10 551 2(x2) 52

0600 22 22 601 2(x3) 53

0650 22 22 651 2(x3) 53

0700 22 22 701 2(x3) 53

Choice of Unit
By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system requirements.

Configuration fields:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 | | | | | | | | | | Code | | Model | Version | Fan | Hydronic | | | | | Kit Size Expansion valve Heat recovery Coil Power supply Code: NRL Size: 0280, 0300, 0330, 0350, 0500, 0550, 0600, 0650, 0700 Thermostatic valve: - Standard mechanical thermostatic valve Y - Mechanical thermostatic valve with processed water from +4C down to -6 C X - Electronic thermostatic valve also with processed water down to +4C (for different temperature contact the head office) Model: F - Free-cooling K - Free-cooling low pressure drops B - Free-cooling glycol free Heat recovery units: - Without recovery units Version: A - High efficiency E - High efficiency, silenced version Batteries: - Aluminium R - Copper S - Tinned copper V - In painted aluminium (epoxy paint) Fans: - Standard M - Oversized Alimentazione: - 400V 3N~ 50Hz with thermomagnetic switches 1 - 220V 3~ 50Hz with thermomagnetic switches Storage tank: (options listed are available only for models "F" free cooling) 00 -without storage tank 03 - high-head storage tank and single pump 04 - high-head storage tank and reserve pump P3 - without storage tank, with high-head pump P4 - without storage tank, with high-head pump and reserve pump

ATTENTION: The B model (free-cooling glycol free) can not be configured with hydronic kit.

Warning: the standard options are shown by the symbol ; Example of the commercial code: NRL0350FA00 This is a size 035 NRL unit with standard mechanical thermostatic valve, Free-cooling model, high efficiency, with aluminium condensing coils, standard fans, electrical panel for compressors with 400V 3N~ 50Hz motors and without storage tank.

185

Technical data
Mod. NRL Free Cooling "F" Vers. A Cooling capacity (kW) E A Total power input (kW) E A Water flow rate (l/h) E A Total pressure drop (kPa) E A EER (W/W) E A Input current (A) E Cooling capacity (kW) A/E Total power input (kW) A/E A Water flow rate (l/h) E A Total pressure drop (kPa) E EER (W/W) A/E Input current (A) A/E Mod. NRL Free Cooling - "K" low pressure drop A Cooling capacity (kW) E A Total power input (kW) E A Water flow rate (l/h) E A Total pressure drop (kPa) E A EER (W/W) E A Input current (A) E Cooling capacity (kW) A/E Total power input (kW) A/E A Water flow rate (l/h) E A Total pressure drop (kPa) E EER (W/W) A/E Input current (A) A/E Mod. NRL Free Cooling - "B" Glycol free Cooling capacity kW BA|BE Total power input kW BA|BE BA Water flow rate (l/h) BE BA Total pressure drop (kPa) BE Input current A BA|BE 0280 59,0 18,1 10150 63 3,26 32 58,0 1,05 10150 95,6 55,24 4,6 60,2 18,1 10351 33,7 3,32 32 56,3 1,05 9937 48,5 53,6 4,6 45 1,85 10150 94 8,1 0300 65,0 21,8 11180 53 2,98 38 68,0 1,05 11180 69,1 64,76 4,6 66,3 21,8 11404 40,6 3,04 38 66,0 1,05 10948 51,3 62,8 4,6 52 1,85 11180 88 8,1 0330 74,0 24,0 12730 66 3,08 41 83,0 1,35 12730 85,8 61,48 5,9 75,5 24,0 12983 35,6 3,15 41 80,5 1,35 12463 49,6 59,6 5,9 64 2,35 12730 90 10,3 0350 82,0 28,3 14100 58 2,90 51 85,0 1,35 14100 82,2 62,96 5,9 83,6 28,3 14386 43,3 2,96 51 82,5 1,35 13811 60,1 61,1 5,9 66 2,35 14100 82 10,3 0500 99,0 91,0 33,7 37,0 17030 15650 60 51 2,93 2,46 61 67 103,0 2,65 17030 15650 79,2 67 38,87 5,9 101,0 92,8 33,7 37,0 17369 15965 44,4 37,5 3,00 2,51 61 67 98,0 2,65 16674 15327 56,8 48,0 37,0 5,9 79 3,65 17030 15650 92 78 8,1 0550 104,0 95,0 37,3 40,0 17890 16340 69 58 2,79 2,37 65 70 104,0 2,65 17890 16340 90,1 75 39,25 5,9 106,1 96,9 37,3 40,0 18246 16667 36,5 30,5 2,84 2,42 65 70 99,0 2,65 17516 16000 50,4 42,0 37,3 5,9 80 3,65 17890 16340 101 84 8,1 0600 132,0 119,0 44,5 49,2 22700 20470 78 63 2,96 2,42 79 87 137,0 3,9 22700 20470 107,9 88 35,13 8,7 134,6 121,4 44,5 49,2 23158 20878 41,7 33,9 3,03 2,47 79 87 121,1 3,9 22232 20042 58,0 47,1 31,1 8,7 104 5,2 22700 20470 101 82 11,6 0650 144,0 130,0 51,7 59,8 24770 22360 73 60 2,79 2,17 84 97 159,0 3,9 24770 22360 107,2 87 40,77 8,7 146,9 132,6 51,7 59,8 25264 22807 39,9 32,5 2,84 2,22 84 97 139,3 3,9 24253 21895 57,8 47,1 35,7 8,7 122 5,7 24770 22360 104 85 12,7 0700 159,0 147,0 60,8 65,8 27350 25280 87 74 2,62 2,23 101 109 174,0 5,4 27350 25280 124,1 106 32,22 11,6 162,2 149,9 60,8 65,8 27895 25790 49,0 41,9 2,67 2,28 101 109 152,5 5,4 26779 24758 70,9 60,6 28,2 11,6 133 7,7 27350 25280 120 103 16,5

Cooling: water outlet temperature 7 C; outside air temp. 35 C; t = 5C.

Cooling in Free-Cooling mode water inlet temperature 15C; outside air temperature 2C; nominal water flow rate; compressors off.

Cooling in Free-Cooling Glycol free water inlet temperature 15C; outside air temperature 2C; nominal water flow rate; compressors off.

186

Technical data
Mod. NRL Free Cooling "F" Maximum current (FLA) Starting current (LRA) Compressors/circuits Vers. A/E A/E A/E A Sound power dB(A) E A Sound pressure dB(A) E Plumbing connections () 0 Motor input power (kW) A/E Motor input current (A) A/E A Air flow rate (m3/h) E Hydronic kit for models only "F" Free Cooling Tank capacity (l) A/E Input power (kW) A/E pump motor Input current (A) A/E pump motor A Useful head (chiller) kPa E A Useful head (freecooling) kPa E Mod. NRL Free Cooling - "B" Glycol free Sound power dB(A) BA|BE Sound pressure dB(A) BA|BE Air flow rate (m3/h) BA|BE (A) (A) (n/n) 0280 46 155 2/2 74 42 2"1/2 0,9 3,9 20000 300 1,5 3,6 124 88 74 42 20000 0300 53 184 2/2 74 42 2"1/2 0,9 3,9 19000 300 1,5 3,6 132 115 74 42 19000 0330 58 190 2/2 75 43 2"1/2 1,2 5,2 25000 300 1,5 3,6 110 88 75 43 25000 0350 63 200 2/2 76 44 2"1/2 1,2 5,2 25000 300 1,5 3,6 118 91 76 44 25000 0500 76 214 3/2 82 74 50 42 2"1/2 2,5 5,6 32500 23400 300 1,85 5 144 160 123 142 82 50 32500 0550 81 220 3/2 82 74 50 42 2"1/2 2,5 5,6 32500 24100 300 1,85 5 132 151 109 131 82 50 32500 0600 100 232 4/2 82 74 50 42 2"1/2 3,75 8,4 50000 33500 300 3 5,7 147 174 114 147 83 51 50000 0650 112 243 4/2 83 75 51 43 2"1/2 3,75 8,4 49000 35300 300 3 5,7 137 169 122 156 84 52 49000 0700 122 261 4/2 85 77 53 45 2"1/2 5,25 11,3 56000 47600 300 3 5,7 99 131 77 115 87 55 56000

SOUND POWER Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

SOUND PRESSURE Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Dimensions (mm)

Mod. NRL Height Width Depth Weight when empty

A B C A

U.M. (mm) (mm) (mm) (kg)

Vers. A/E A/E A/E 00 FA/FE BA/BE -

280 1606 1100 2950 838

300 1606 1100 2950 908

330 1606 1100 2950 913

350 1606 1100 2950 922

500 1875 1100 3200 1079

550 1875 1100 3200 1083

600 1875 1100 3950 1386

650 1875 1100 3950 1460

700 1875 1100 3950 1540

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

187

Cod.: SNRLFCUY.10 /1301

NRL

0750/1800 free-cooling

Air cooled chillers with axial fans Cooling capacity from 177 kW to 452 kW

R410A

HIGH EFFICIENCY VERSION LOW NOISE HIGH EFFICIENCY VERSION PUMP ASSEMBLY OPTION
Characteristics
Available in 9 sizes Refrigerant R410A 2 refrigerant circuits High efficiency even at part load Heat exchangers optimised to benefit from the excellent heat transfer characteristics of R410A High efficiency scroll compressors Axial fans with low sound level Solid construction with polyester anti-corrosion painted finish Operation up to 44 C ambient in cooling mode Operation modes: -  Free-Cooling only: is the most economical way to use the unit. Only the fans operate by speed control. Cooling is achieved completely from the external air temperature -  combined Free-Cooling and compressors:

2 REFRIGERANT CIRCUITS PUMP ASSEMBLY AND BUFFER TANK OPTION

the cooling capacity is achieved from the external air temperature combined with compressor operation at full or partial load -  compressors only: the cooling capacity is provided entirely by the compressors (standard operation of a chiller) Versions available: - High efficiency - High efficiency low noise - Glycol free -  With pump assembly (high head, with/without standby pump) -  With pump assembly and 700 litre buffer tank (500 litres for size 750), complete with water filter, flow switch, expansion tank, charging point and antifreeze electric heater - Electronic expansion valve - Inverter fans Microprocessor control system of the com-

pressors and fans for the control of the three operating modes (Free-Cooling only, combined Free-Cooling and compressors, and compressors only) Display of all operating parameters in 4 languages. Simplified remote control panel located up to 50 m distance away with shielded cable. Permits basic control and alarm notifications of the unit High efficiency air-water coil (Free-Cooling) with smooth tubes and wavy fins Three-way valve installed on the hydraulic circuit to modulate flow to the Free-Cooling coils High and low pressure transducers (standard for all versions) Fan speed controller for low ambient operation. In Free-Cooling mode controls capacity

Accessories
AERSET: The AERSET accessory allows the off cycles) and different programmes for each automatic compensation of the operating setday of the week. point of the unit to which it is connected, RIF: Power factor correction. Connected in based on a 0-10V MODBUSinput signal. parallel to the motor allowing about 10% Mandatory accessory: AER485 or MODUreduction of input current. Must be requested 485A at time of order and is available factory fitted AER485: RS-485 interface for supervision sysonly. tems with MODBUS protocol. AERWEB300: Accessory AERWEB allows AVX: spring anti-vibration mounts Select the remote control of a chiller through a comAVX model from the compatibility table. mon PC and an ethernet connection over a DRE: Soft starter (current reduction of about common browser; 4 versions available: 30% for single circuit units, 26% for two cirAERWEB300-6: Web server to monitor and cuit units, 22% for three circuit units). Only remote control max. 6 units in RS485 netavailable for 400V-3-phase power supply. work; Factory fitted only. AERWEB300-18: Web server to monitor and GP: Protection grille protects the external coil remote control max. 18 units in RS485 netfrom accidental damage. work; PGS: Daily/Weekly Programmer. Allows two AERWEB300-6G: Web server to monitor and daily time-clock programmes (two switch on/ remote control max. 6 units in RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; DUALCHILLER: Simplified control system to switch on/off and control two chillers in a single system (using Aermec GR3 command), as if they were a single unit. MULTICHILLER: Control system for multiple parallel installed constant flow chillers providing individual chiller on/off and control capability. PRM1 and PRM2: FACTORY FITTED ACCESSORY. A manual reset pressure switch wired in series with the existing high pressure switch installed on the compressor discharge line.

188

Mod. NRL AERSET AER485 DUALCHILLER MULTICHILLER PGS AERWEB300 VT

AVX DRE GP RIF PRM1-PRM2

Vers. All All All All All All 00 - P3 - P4 03 - 04 00 P3 - P4 03 - 04 All All All All

0750 4 4 4 4 4 23 23 751 10 (x3) 53 4

0800 4 4 4 4 4 739 741 740 801 260 88 4

Accessory compatibility 0900 1000 4 4 4 4 4 4 4 4 4 4 739 745 744 747 743 746 901 1001 260 260 90 92 4 4

1250 4 4 4 4 4 748 750 749 1251 350 92 4

1404 4 4 4 4 4 752 754 753 1404 350 92 4

1504 4 4 4 4 4 757 758 753 1504 350 92 4

1655 4 4 4 4 4 761 763 762 1655 500 93 4

1800 4 4 4 4 4 766 763 762 1801 500 94 4

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 4567 8 9 10 11 12 13 14 | | | | | | | | | Code | | Model | Version | Fan | | | | | | Size Expansion valve Heat recovery Coil Power supply 15-16 | Integrated hydronic module

Code: NRL Size: 0750, 0800, 0900, 1000, 1250, 1404, 1504, 1655, 1800 Expansion valve: - Standard thermostatic expansion valve Y - Thermostatic expansion valve with leaving liquid temperature from +4C down to -6 C X - Electronic thermostatic valve, max. temp. of water produced: +4C (for lower temperatures please contact us) Model: F - Free-cooling K - Free-cooling low pressure drop B - Free-cooling glycol free Heat recovery - Without heat recovery Version: A - High efficiency E - High efficiency low noise version

Coil: - Aluminium R - Copper S - Tinned copper V - Anti-corrosion coated aluminium (epoxy paint) Fan: - Standard J - Inverter Power supply: - 400V 3N~ 50Hz with circuit breakers (only NRL 0750 model) - 400V 3~ 50Hz with circuit breakers Integrated hydronic module: 00 - without pump or buffer tank 03 - single high head pump and buffer tank 04 - single and standby high head pump and buffer tank P3 - single high head pump without buffer tank P4 - single and standby high head pump without buffer tank

WARNING: NRL "B" size 750 can not be provided with hydronic kit 03-04-P3-P4 NRL "B" size 800-1800 can not be provided with hydronic kit 03-04

Attention: the standard options are shown by the symbol Example of configuration code: NRL0750FA00 This is an NRL unit of size 750, with standard thermostatic expansion valve, Free-cooling model, without heat recovery, high efficiency, with aluminium condenser coils, standard fans, and electrical panel for compressor motors 400V 3N~ 50Hz, and without pump or buffer tank.

189

Technical Data
Mod. NRL Free Cooling Vers. FA Cooling capacity (kW) FE FA Total power input (kW) FE FA Water flow rate (l/h) FE FA Total pressure drop (kPa) FE FA EER (W/W) FE FA Input current (A) FE FA Cooling capacity (kW) FE Total power input (kW) Tutte FA Water flow rate (l/h) FE FA Total pressure drop (kPa) FE FA EER (W/W) FE Input current (A) FA/FE Mod. NRL Free Cooling - "K" low pressure drop FA Cooling capacity (kW) FE FA Total power input (kW) FE FA Water flow rate (l/h) FE FA Total pressure drop (kPa) FE FA EER (W/W) FE FA Input current (A) FE Cooling capacity FA/FE (kW) Total power input FA/FE (kW) FA Water flow rate FE (l/h) FA Total pressure drop (kPa) FE EER (W/W) FA/FE Input current (A) FA/FE Mod. NRL Free Cooling Glycol free Cooling capacity kW Tutte Total power input kW Tutte BA Water flow rate (l/h) BE BA Total pressure drop (kPa) BE Input current glycol free A BA|BE U.M. 0750 191 177 69,6 76,4, 32850 30440 103 89 2,75 2,32 123 135 187 187 5,4 32850 30440 156,3 134 34,63 34,63 11,6 194,8 180,5 69,6 76,4 33509 31053 34,6 29,7 2,80 2,36 123 135 165,3 5,4 32169 29811 63,9 54,9 30,6 11,6 143 7.7 32850 30440 130 112 16.5 0800 210 196 75 80 36120 33730 77 68 2,81 2,46 144 149 182 178 7,5 36120 33730 105 93 24,30 23,76 15 214,2 199,9 75,0 80,0 36843 34387 64,8 56,5 2,86 2,50 144 149 174,6 7,5 35369 33011 88,3 76,9 23,3 15 153 11.1 36111 33734 94 87 21 0900 229 216 89 93 39390 37110 82 73 2,58 2,33 169 174 206 201 7,5 39390 37110 110 99 27,48 26,76 15 233,6 220,3 89,0 93,0 40176 37895 65,8 58,6 2,62 2,37 169 174 199,1 7,5 38569 36380 86,9 77,3 26,6 15 170 11.1 39334 37106 102 94 21 1000 247 228 103 109 42480 39210 81 69 2,41 2,09 195 203 229 223 7,5 42840 39210 110 94 30,53 29,76 15 251,9 232,6 103,0 109,0 43334 40001 70,2 59,8 2,45 2,13 195 203 223,7 7,5 41601 38401 91,2 77,7 29,8 15 186 11.1 42557 39206 103 94 21 1250 310 289 114 120 53320 49670 92 80 2,72 2,40 208 217 257 263 11,0 53320 49670 123 106 23,34 23,89 22 316,2 294,8 114,0 120,0 54387 50703 65,6 57,0 2,77 2,46 208 217 242,2 11 52212 48675 87,1 75,7 22,0 22 217 17.3 53345 49665 108 99 33 1404 337 310 136 145 57960 53260 98 84 2,48 2,14 252 265 291 288 11,0 57960 53260 131 110 26,47 26,19 22 343,7 316,2 136,0 145,0 59124 54387 69,1 58,5 2,53 2,18 252 265 275,0 11 56759 52212 90,9 76,9 25,0 22 242 17.3 57936 53259 117 105 34 1504 364 331 157 169 62610 56850 83 70 2,31 1,95 296 312 326 314 11,0 62610 56850 117 94 29,61 28,50 22 371,3 337,6 157,0 169,0 63861 58071 75,2 62,2 2,36 2,00 296 312 307,9 11 61306 55748 97,3 80,4 28,0 22 266 17.3 62526 56853 104 94 34 1655 430 400 159 169 73960 68770 104 90 2,70 2,37 298 310 399 396 14,5 73960 68770 140 117 27,48 27,33 30 438,6 408,0 159,0 169,0 75440 70177 95,5 82,6 2,76 2,41 298 312 378,5 14,5 72422 67370 125,6 108,7 26,1 30 328 23.2 73935 68770 108 99 45 1800 452 421 175 186 77740 72330 107 93 2,58 2,26 317 332 440 443 14,5 77740 72330 145 120 30,32 30,58 30 461,0 429,4 175,0 186,0 79300 73861 105,2 91,3 2,63 2,31 317 332 420,2 14,5 76128 70907 135,6 117,6 29,0 30 361 23.2 77730 72329 112 102 45

Cooling leaving water temperature 7C; external air temperature 35C; t = 5 C;

Cooling in Free-Cooling mode: entering water temperature 15C; external air temperature 2C; nominal water flow rate; compressors off.

Cooling in Free-Cooling Glycol free entering water temperature 15C; external air temerature 2C; nominal water flow rate; compressors off.

190

Technical Data
Mod. NRL Free Cooling Maximum current (FLA) Starting current (LRA) Compressors/circuits Sound power Sound pressure Air flow rate Pump assembly option Tank capacity Input power pump motor Input current pump motor Useful head (Chiller) Useful head (Free-cooling) U.M. (A) (A) (n/n) dB(A) db(A) () (m3/h) (l) (kW) (A) kPa kPa Vers. FA/FE FA/FE FA/FE FA FE FA FE (00) FA FE FA/FE FA/FE FA/FE FA FE FA FE BA|BE BA|BE BA|BE 0750 144 320 4/2 87 82 55 50 21/2 56000 46500 500 5,5 11 177 200 119 150 87 55 56000 0800 177 352 4/2 88,5 82,5 56,5 50,5 3 79600 55700 700 6,5 11,0 220 233 194 211 88.5 56.5 79600 0900 199 408 4/2 88,5 82,5 56,5 50,5 3 78800 55200 700 6,5 11,0 210 222 184 202 88.5 56.5 78800 1000 221 430 4/2 88,5 82,5 56,5 50,5 3 78000 55800 700 6,5 11,0 204 223 177 203 88.5 56.5 78000 1250 274 542 4/2 91,5 85,5 59,5 53,5 4 115200 80600 700 8,6 14,6 242 262 214 245 91.5 59.5 115200 1404 290 624 4/2 91 85 59,0 53,0 4 114000 79800 700 8,6 14,6 223 250 195 234 91 59.0 114000 1504 320 654 4/2 90,5 84,5 58,5 52,5 4 112800 80700 700 8,6 14,6 224 255 195 242 90.5 58.5 112800 1655 357 691 5/2 92 86 60,0 54,00 4 155200 108600 700 12,3 21,2 192 214 165 197 92 60.0 155200 1800 406 674 6/2 94 88 62,0 56,0 4 153600 109800 700 12,3 21,2 182 206 155 189 94 62.0 153600

Hydraulic connections

Mod. NRL Free Cooling Glycol free Sound power db(A) Sound pressure db(A) Air flow rate (m3/h)

e Sound pressure: Sound power: Aermec determines the value based on the measured in free field measurements made in compliance with conditions, in cooling mode, at distance of the standard ISO 9614 - 2, respecting 10m and directivity factor = 2. Eurovent requirements. In accordance with the ISO 3744 Power supply voltage: 400 V

Dimensions (mm)

290

1500

C
B

Mod. NRL-F / NRL-B U.M. Vers. 0750 0800 0900 1000 Height A (mm) A/E 1955 2450 2450 2450 Width B (mm) A/E 1500 2200 2200 2200 Length C (mm) A/E 4350 3400 3400 3400 Weight empty A (kg) A/E 1889 2470 2650 2840
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

1250 2450 2200 4250 3120

1404 2450 2200 4250 3380

1504 2450 2200 4250 3660

1655 2450 2200 5750 4220

1800 2450 2200 5750 4420

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

191

Code: SNRLFCUY.03 / 1301

NRL

2000/3600 free-cooling

Air cooled chiller with axial fans Cooling capacity from 446 kW to 904 kW

R410A

HIGH EFFICIENCY VERSION LOW NOISE HIGH EFFICIENCY VERSION PUMP ASSEMBLY OPTION
Characteristics
Available in 7 sizes Refrigerant R410A 4 refrigerant circuits High efficiency even at part load Heat exchangers optimised to benefit from the excellent heat transfer characteristics of R410A High efficiency scroll compressors Axial fans with low sound level Solid construction with polyester anti-corrosion painted finish Operation up to 44 C ambient in cooling mode Operation modes: -  Free-Cooling only: is the most economical way to use the unit. Only the fans operate by speed control. Cooling is achieved completely from the external air temperature -  combined Free-Cooling and compressors: the cooling capacity is achieved from the

4 REFRIGERANT CIRCUITS PUMP ASSEMBLY AND BUFFER TANK OPTION

external air temperature combined with compressor operation at full or partial load -  compressors only: the cooling capacity is provided entirely by the compressors (standard operation of a chiller) Versions available: - High efficiency - High efficiency low noise - Glycol free -  With pump assembly (high head, with/without standby pump) -  With pump assembly and 700 litre buffer tanks complete with water filter, flow switch, expansion tank, charging point and antifreeze electric heater - Electronic expansion valve - Inverter fans Microprocessor control system of the compressors and fans for the control of the three

operating modes (Free-Cooling only, combined Free-Cooling and compressors, and compressors only) Display of all operating parameters in 4 languages. Simplified remote control panel located up to 50 m distance away with shielded cable. Permits basic control and alarm notifications of the unit High efficiency air-water coil (Free-Cooling) with smooth tubes and wavy fins Three-way valve installed on the hydraulic circuit to modulate flow to the Free-Cooling coils High and low pressure transducers (standard for all versions) Fan speed controller for low ambient operation. In Free-Cooling mode controls capacity.

Accessories
AER485P1: RS-485 interface for supervision systems with MODBUS protocol. AVX: spring anti-vibration mounts Select the AVX model from the compatibility table. GP: Protection grille protects the external coil from accidental damage. PGS: Daily/Weekly Programmer. Allows two daily time-clock programmes (two switch on/ off cycles) and different programmes for each day of the week. RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted only. PRM1 and PRM2: FACTORY FITTED ACCESSORY. A manual reset pressure switch wired in series with the existing high pressure switch installed on the compressor discharge line.

192

Accessory compatibility
Mod. NRL AER485P1 PGS TRX1 GP RIF PRM1/PRM2 AVX (00) AVX (03-04) AVX (P3-P4) Vers. All All All A-E A-E All A-E A-E A-E 2000 4 4 4 260 x 2 RIFNRL2000 2250 4 4 4 260 - 350 RIFNRL2250 2500 4 4 4 350 x 2 RIFNRL2500 2808 4 4 4 350 x 2 RIFNRL2808 3008 4 4 4 350 x 2 RIFNRL3008 3310 4 4 4 500 x 2 RIFNRL3310 3600 4 4 4 500 x 2 RIFNRL3600

770 771 772

776 777 778

782 783 784

788 789 790

794 795 796

801 802 803

801 802 803

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 4567 8 9 10 11 12 13 14 | | | | | | | | | Code | | Model | Version | Fan | | | | | | Size Expansion valve Heat recovery Coil Power supply 15-16 | Integrated hydronic module

Code: NRL Size: 2000, 2250, 2500, 2808, 3008, 3310, 3600 Expansion valve: - Standard thermostatic expansion valve Y - Thermostatic expansion valve with leaving liquid temperature from +4C down to -6 C X - Electronic thermostatic valve, max. temp. of water produced: +4C (for lower temperatures please contact us) Model: F - Free-cooling B - Free-cooling glycol free Heat recovery - Without heat recovery D - With desuperheater (partial heat recovery) Version: A - High efficiency E - High efficiency low noise version

Coil: - Aluminium R - Copper S - Tinned copper V - Anti-corrosion coated aluminium (epoxy paint) Fans: - Standard J - Inverter Power supply: - 400V 3~ 50Hz with circuit breakers Integrated hydronic module: 00 - without pump or buffer tank 03 - single high head pump and buffer tank 04 - single and standby high head pump and buffer tank P3 - single high head pump without buffer tank P4 - single and standby high head pump without buffer tank

WARNING: The model "B" (Free-cooling, Free-cooling glycol free) glycol can not be provided with hydronic kit 03-04

Attention: the standard options are shown by the symbol Example of configuration code: NRL2000FA00 This is an NRL unit of size 2000, with standard thermostatic expansion valve, Free-cooling model, without heat recovery, high efficiency, with aluminium condenser coils, standard fans, and electrical panel for compressor motors 400V 3~ 50Hz, and without pump or buffer tank.

193

Technical Data
Mod. NRL Cooling capacity Total power input Water flow rate Total pressure drop EER Input current Cooling capacity Total power input Water flow rate Total pressure drop EER Input current Maximum current (FLA) Starting current (LRA) Compressors/circuits Sound power Sound pressure Hydraulic connections Air flow rate Pump assembly option Buffer tank capacity Input power motor pump Input current motor pump Useful head (Chiller) Useful head (Freecooling) U.M. kW kW l/h kPa W/W A kW kW l/h kPa W/W A A A n/n dB(A) dB(A) m3/h nx l kW A kPa kPa Vers. A E A E A E A E A E A E A E All A E A E A E A/E A/E A/E A/E A E A E All A E All All All A E A E 2000 494 456 206 218 84970 78430 81 69 2,40 2,09 389 407 458 446 15 85115 78413 110 94 30,53 29,73 30 442 651 8/4 91,5 85,5 59,5 53,5 3" 156000 111600 2x700 13,0 22,0 204 223 177 199 2250 557 517 217 229 95800 88920 92 80 2,57 2,26 403 421 486 486 19 95903 88871 123 107 25,58 25,58 37 495 763 8/4 93,3 87,3 61,5 55,3 3"/4 193200 136400 2x700 6.5+8.6 11+14.6 242 262 214 239 2500 620 578 228 240 106640 99420 92 80 2,72 2,41 417 435 514 526 22 106691 99330 123 107 23,36 23,91 44 548 816 8/4 94,5 88,5 62,5 56,5 4" 230400 161200 2x700 17,2 29,2 242 262 214 239 2808 674 620 272 290 115930 106640 98 84 2,48 2,14 504 529 582 576 22 115871 106518 131 111 26,45 26,18 44 606 815 8/4 94,0 88,0 62,0 56,0 4" 228000 159600 2x700 17,2 29,2 223 250 195 226 3008 728 662 314 338 125220 113860 83 70 2,32 1,96 592 624 652 627 22 125052 113706 117 97 29,64 28,50 44 664 873 8/4 93,5 87,5 61,5 55,5 4" 225600 161400 2x700 17,2 29,2 224 255 195 231 3310 860 800 318 338 147920 137600 104 90 2,70 2,37 597 621 798 792 29 147870 137540 140 122 27,52 27,31 59 747 1015 10/4 95,0 89,0 63,0 57,0 4" 310400 217200 2x700V 24,7 42,4 192 214 165 191 3600 904 842 350 372 155490 144820 107 93 2,58 2,26 634 665 880 887 29 155459 144658 145 126 30,34 30,59 59 813 1081 12/4 97,0 91,0 65,0 59,0 4" 307200 219600 2x700 24,7 42,4 182 206 155 182

Cooling leaving water temperature 7C; external air temperature 35C; t = 5 C; Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

Cooling in Free-Cooling mode: entering water temperature 15C; external air temperature 2C; nominal water flow rate; compressors off. Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

194

Dimensions (mm)

C B

Mod. NRL-F / NRL-B Height Width Length Weight empty A B C

U.M. (mm) (mm) (mm) (Kg)

Vers. A/E A/E A/E A/E

2000 2450 2200 6400 5670

2250 2450 2200 7250 6190

2500 2450 2200 8100 6700

2800 2450 2200 8100 7120

3000 2450 2200 8100 7580

3300 2450 2200 11100 9060

3600 2450 2200 11100 9330

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

195

Code: SNRLMSFCUY.03 / 1301

NRC
R407C

Air cooled chillers, heat pumps and condensing units with centrifugal fans Capacities from 46 to 263 kW

Aermec participates in the EUROVENT programme: LCP / A / P / C The products involved can be found at the website www. eurovent-certification.com

STANDARD VERSION OPTION FOR PUMP


Features
Available in 13 sizes Cooling only, heat pump and condensing unit versions All versions manufactured with refrigerant R407c Options for partial or total heat recovery 4 versions available: - With loose supplied water filter and differential pressure switch - With pump only - With low head pump assembly, 500 litre buffer tank (700 litres for sizes 800 to 1000) with 300 W anti-freeze heater (2 x 300 W for sizes 750 to 1000), water filter fitted, and flow switch - With high head pump assembly, 500 litre buffer tank (700 litres for sizes 800 to 1000) with 300 W anti-freeze heater (2 x 300 W for sizes 750 to 1000), water filter fitted, and flow switch

OPTION FOR PUMP AND BUFFER TANK


Simplified remote control panel. Provides access to all the unit basic control functions and alarm notification High efficiency plate heat exchangers Evaporator trace heating Compressor crank case heater Low pressure transducer (standard on heat pump models) High pressure transducer (standard on heat pump models and cooling only sizes 500 to 1000) Air discharge: top discharge for sizes 275 to 550 and front discharge for sizes 600 to 1000 (with top discharge on request) Centrifugal fans Compact size Metallic protective cabinet with anti-corrosion polyester paint

Cooling only version can be requested for low leaving liquid temperatures 4 C down to -6 C. This option must be specified at the time of order All the versions can be requested with high static pressure fans which allows nominal air flow rates with higher static pressure installations. This option must be specified at time of order. Please refer to the technical manuals for technical data The versions with pump and/or buffer tank are also fitted with automatic air vent valve, filling point, expansion tank and water pressure relief valve High efficiency scroll compressors with low power input Modulating microprocessor control system Functional parameters can be displayed in 4 languages

Accessories
AER485: RS-485 interface for supervision systems with MODBUS protocol. AERSET The AERSET accessory allows the automatic compensation of the operating setpoint of the unit to which it is connected, based on a 0-10V MODBUS input signal. Mandatory accessory: AER485 or MODU-485A AVX: Spring anti-vibration mounts. Select the AVX model by using the compatibility table. DR: Low temperature device, consisting of a damper for installation on the fan outlet, modulates air flow to the condenser based on the pressure transducer value. The DR 202 - 402 accessories also include the TP2 high pressure transducers. Accessory obligatory in D versions. DRE: Current soft starter device (about 30% reduction for single-circuit-units, 26% for two-circuit-units, 22% for three-circuit-units). Only available for 400V-3-phase power supply. Factory fitted only PGS: Daily/Weekly Programmer. Allows two daily time-clock programmes (two switch on/ off cycles) and different programmes for each day of the week. RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted only. AERWEB300: The AERWEB option allows remote control of a chiller through a standard PC and an ethernet connection with a standard browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control maximum 6 units on RS485 network; AERWEB300-18: Web server to monitor and remote control maximum 18 units on RS485 network; AERWEB300-6G: Web server to monitor and remote control maximum 6 units on RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control maximum 18 units on RS485 network with integrated GPRS modem. TP 1: Low pressure transducer, providing display of operating pressure (one per circuit). Standard on heat pump models. TP 2: High pressure transducer, providing display on the microprocessor controller of working pressure (one per circuit). Standard on heat pump models and cooling only sizes 500 to 1000. VT: Anti-vibration mounts, set of four mounts to be installed under the unit base. DUALCHILLER: Simplified control system to switch on/off and control two chillers in a single system (using Aermec GR3 command), as if they were a single unit. MULTICHILLER: Control system for multiple parallel installed constant flow chillers providing individual chiller on/off and control capability.

196

Accessory compatibility
Mod. AER485 AERSET DUALCHILLER MULTICHILLER AVX DR 200 DR 400 DR 202 DR 402 DR 600 DR 800 DRE 275 DRE 300 DRE 325 DRE 10 DRE 15 DRE 25 DRE 30 PGS RIF AERWEB300 TP 1 TP 2 VT 14* VT 16* VT 17 VT 2 (x2) (x2) (x2) (x2) (x4) (x4) (x2) (x2) (x4) (x2) 275 ** 300 ** 325 ** ** ** ** 350 500 550 600 650 700 750 800 900 1000 401/402* 401/402* 402/403* 402/403* 404/406* 404/406* 405/407*

(x2) (x4) 62 62 62 82 63 63 64 64 64 64 64 74 84 (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)*** (x2)***

DR = Accessory obligatory for D versions. * = To be used in versions with buffer tank. ** = To be used in heat pump models.

*** = Standard on heat pump models. N.B. = number in brackets indicates required quantity.

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 | | | | | | | | | | Code | Field of use | Heat recovery | Coil | Power supply | | | | | | Size Model Version Evaporator Integrated hydronic module Code: NRC Size: 0275, 0300, 0325, 0350, 0500, 0550 0600, 0650, 0700, 0750, 0800, 0900, 1000 Field of use: - Standard with leaving water above +4 C Y - Low temperature with leaving liquid down to -6 C Model: - Cooling only H - Heat pump Heat recovery: - Without heat recovery D - With desuperheaters (partial heat recovery) T - With total heat recovery Version: - Standard L - Low noise Coil: - Aluminium R - Copper S - Tinned copper V - Coated aluminium Evaporator: - To PED regulations G - To TV-D regulations (Germany) C - Condensing unit (without evaporator) Power supply: - 400V 3~ 50Hz* with circuit breakers 4 - 230V 3~ 50Hz with circuit breakers 9 - 500V 3~ 50Hz with circuit breakers Integrated hydronic module: 00 - without pump or buffer tank 01 - single low head pump and buffer tank 02 - single and standby low head pump and buffer tank 03 - single high head pump and buffer tank 04 - single and standby high head pump and buffer tank 05 - single low head pump and buffer tank (with holes for immersion heaters) 06 - single and standby low head pump and buffer tank (with holes for immersion heaters) 07 - single high head pump and buffer tank (with holes for immersion heaters) 08 - single and standby high head pump and buffer tank (with holes for immersion heaters) P1 - single low head pump without buffer tank P2 - single and standby low head pump without buffer tank P3 - single high head pump without buffer tank P4 - single and standby high head pump without buffer tank

Attention: standard options are shown by the symbol the following options are not available for heat pump models: Y, T, L and C * (400V 3N~ 50Hz sizes 275,300, 325, 350, 500, 550, 600, 650, 700, 750 / 400V 3~ 50Hz 800, 900, 1000)

197

Technical Data
Cooling only models Cooling capacity (kW) Total input power (kW) Input current (A) Water flow rate (l/h) Pressure drop (kPa) EER Total air flow rate (m3/h) Sound pressure dB(A) Capacity steps (n.) Fans (n.) Fan speed (rpm) Maximum current (A) Starting current (A) Crank case electric heater (W) Anti-freeze heater (W) Water connections () * Buffer tank capacity (l) Available head (kPa) - gr1** Available head (kPa) - gr2** Heat pumps model Cooling capacity Total input power EER Input current Water flow rate Pressure drop Heating capacity Total input power COP Input current Water flow rate Pressure drop Total air flow rate Sound pressure Capacity steps Fans Fan speed Maximum current Starting current Crank case electric heater Anti-freeze heater Water connections () * Buffer tank capacity Available head - gr1** Available head - gr2** Compressors / circuits L L kW kW A l/h kPa kW kW A l/h kPa m3/h dB (A) n. n. n. rpm A A W W 00-P1/P4 01/08 l kPa kPa 00-P1/P4 01/08 L L Vers. L L L L L L L L 275 51 46 22,3 23,0 40,3 40,5 8772 7911 39,0 31,7 2,27 1,99 16000 11000 53.0 49.0 2/2 2 2 630 540 54 153 152 2x75 300 M/2" F/2" 500 127 139 160 172 275 H 49 21,6 2,26 39,7 8428 36,0 60 22,84 2,63 44,0 10262 49,4 16000 53.0 2/2 2 2 630 54 155 2x75 300 M/2" F/2" 500 132 165 300 59 54 26,4 26,6 46,5 45,8 10148 9288 33,0 27,6 2,22 2,02 22000 15500 53.0 49.0 2/2 2 2 570 500 63 161 158 2x75 300 M/2" F/2" 500 126 138 160 171 300 H 57 25,9 2,19 45,8 9804 30,8 69 26,88 2,58 50,7 11853 41,6 22000 53.0 2/2 2 2 570 63 162 2x75 300 M/2" F/2" 500 131 165 325 67 62 29,7 30,0 51,3 50,7 11524 10664 34,0 29,1 2,24 2,06 22000 15500 54.0 50.0 2/2 2 2 570 520 71 165 163 2x75 300 M/2" F/2" 500 122 131 155 164 325 H 65 29,1 2,22 50,5 11180 32,0 80 30,08 2,65 56,1 13622 43,9 22000 54.0 2/2 2 2 570 71 168 2x75 300 M/2" F/2" 500 126 160 350 76 70 32,7 33,5 57,5 57,7 13072 12040 45,0 38,2 2,31 2,08 26000 18000 56.0 52.0 2/2 2 2 590 500 80 208 206 2x75 300 M/2" F/2" 500 104 116 138 150 350 H 74 32,1 2,29 56,7 12728 42,7 90 33,09 2,72 62,7 15391 57,7 26000 56.0 2/2 2 2 590 80 210 2x75 300 M/2" F/2" 500 108 142 500 89 81 38,0 40,3 68,1 68,7 15308 13932 28,6 23,7 2,33 2,00 27000 19000 56.0 52.0 3/2 3 2 600 510 93 219 217 3x75 300 M/2" F/2" 500 131 146 171 183 500 H 86 37,2 2,30 67,1 14792 26,7 104 38,64 2,70 74,4 17867 36,0 27000 56.0 3/2 3 2 600 93 222 3x75 300 M/2" F/2" 500 137 176 550 97 89 40,7 43,3 72,1 73,3 16684 15308 23,5 19,8 2,37 2,05 27000 19000 56.0 52.0 3/2 3 2 600 510 99 223 221 3x75 300 M/2" F/2" 500 126 140 171 181 550 H 94 39,9 2,35 71,0 16168 22,1 115 41,48 2,76 78,9 19637 30,1 27000 56.0 3/2 3 2 600 99 227 3x75 300 M/2" F/2" 500 132 175 600 120 110 52,5 47,9 93,4 82,8 20640 18920 32,0 26,9 2,28 2,29 45000 31500 58.0 54.0 4/2 4 3 600 520 131 207 205 4x75 300 M/2" F/2" 500 69 93 148 165 600 H 118 51,5 2,28 92,0 20296 30,9 141 52,25 2,69 101,9 24059 40,2 45000 58.0 4/2 4 3 600 131 213 4x75 300 M/2" F/2" 500 74 151 650 136 126 58,5 54,4 101,5 91,9 23392 21672 28,3 24,3 2,32 2,31 45000 31500 58.0 54.0 4/2 4 3 600 520 143 215 212 4x75 300 M/2" F/2" 500 85 104 176 187 650 H 134 57,0 2,34 99,8 23048 27,5 160 57,65 2,78 110,9 27422 36,0 45000 58.0 4/2 4 3 600 143 223 4x75 300 M/2" F/2" 500 89 178 700 155 141 66,1 62,5 117,0 107,4 26832 24424 36,5 30,2 2,35 2,26 50000 35000 59.0 55.0 4/2 4 3 580 500 164 267 266 4x75 300 M/2" F/2" 500 103 126 123 145 700 H 151 64,6 2,34 115,3 26144 34,7 181 64,99 2,78 127,4 30960 45,0 50000 59.0 4/2 4 3 580 164 275 4x75 300 M/2" F/2" 500 109 129 750 183 168 77,6 73,0 134,5 122,8 31648 28896 27,8 23,2 2,36 2,30 50000 35000 59.0 55.0 4/2 4 3 580 500 190 318 315 2x75 2x130 2x300 M/2" F/2" 500 100 117 217 235 750 H 177 76,6 2,32 133,5 30616 26,0 214 75,71 2,82 145,8 36621 34,4 50000 59.0 4/2 4 3 580 190 326 2x75 2x130 2x300 M/2" F/2" 500 106 224 800 213 193 90,8 83,6 153,7 138,1 36808 33368 35,6 29,3 2,35 2,31 60000 42000 60.0 56.0 4/2 4 4 650 580 225 337 334 4x130 2x300 V3" V3" 700 97 116 212 233 800 H 203 90,2 2,25 153,7 35088 32,4 247 87,59 2,82 166,2 42281 43,5 60000 60.0 4/2 4 4 650 225 346 4x130 2x300 V3" V3" 700 107 223 900 237 215 100,7 94,6 171,7 155,8 40936 37152 30,3 25,0 2,36 2,28 68000 47600 60.0 56.5 4/2 4 4 600 530 245 404 401 4x130 3x300 V3" V3" 700 95 115 209 230 900 H 229 100,7 2,28 172,7 39560 28,3 276 97,91 2,81 186,5 47235 37,3 68000 60.0 4/2 4 4 600 245 414 4x130 2x300 V3" V3" 700 102 217 1000 263 237 113,3 105,2 193,2 173,4 45408 40936 30,6 24,9 2,32 2,26 68000 47600 60.0 56.5 4/2 4 4 700 600 277 424 419 4x130 2x300 V3" V3" 700 82 106 194 220 1000 H 253 112,7 2,25 192,9 43688 28,3 304 108,29 2,81 206,9 52188 37,4 68000 60.0 4/2 4 4 700 277 435 4x130 2x300 V3" V3" 700 91 204

Compressors / circuits (n.)

* = M: male; F: female; V: Victaulic. ** = gr1 (Low head pump assembly); gr2 (High head pump assembly)

Data declared in accordance with UNI EN 14511:2011 Performance values refer to the following conditions: Cooling leaving water temperature 7 C external air temperature 35 C t = 5C Heating leaving water temperature 50 C external air temperature 7 C db / 6 C wb t = 5C

e Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744) - Power supply: 400 V

198

Dimensions (mm)

NRC 275 - 550 without buffer tank

NRC 275 - 550 with buffer tank

NRC 600 - 1000 without buffer tank

NRC 600 - 1000 with buffer tank

Model. NRC 00 (without buffer tank) A B C Weight (kg) mm mm mm NRC NRC H 275 1763 2100 950 629 689 300 1793 2100 950 665 737 325 1793 2100 950 699 748 350 1763 2450 950 777 841 500 1963 2450 950 904 983 550 1963 2450 950 919 999 600 2288 3750 1100 1481 1593 650 2288 3750 1100 1498 1610 700 2288 4550 1100 1737 1831 750 2288 4550 1100 1918 2001 800 2295 4950 1300 2670 2797 900 2295 4950 1300 2700 2827 1000 2295 4950 1300 2960 3095

Model NRC P1/P4 (with pumping assembly) 275 A mm 1763 B mm 2100 C mm 950 NRC 663 Weight (kg) NRC H 723

300 1793 2100 950 699 771

325 1793 2100 950 733 782

350 1763 2450 950 811 875

500 1963 2450 950 938 1017

550 1963 2450 950 953 1033

600 2288 3750 1100 1659 1771

650 2288 3750 1100 1676 1788

700 2288 4550 1100 1914 2009

750 2288 4550 1100 2096 2179

800 2295 4950 1300 2870 2997

900 2295 4950 1300 2900 3027

1000 2295 4950 1300 3160 3295

Note: the weights given for the versions with buffer tank refer to the empty weight.

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

199

Cod.: SNRCUY.14 / 1301

Mod. NRC 01/08 (with buffer tank unit and pump) 275 300 A mm 1763 1793 B mm 2950 2950 C mm 950 950 NRC 827 891 Weight (kg) NRC H 865 920

325 1793 2950 950 901 930

350 1763 3300 950 996 1030

500 1963 3300 950 1121 1194

550 1963 3300 950 1138 1210

600 2288 4550 1100 1743 1855

650 2288 4550 1100 1760 1872

700 2288 5350 1100 1998 2093

750 2288 5350 1100 2180 2263

800 2295 5750 1300 3070 3190

900 2295 5750 1300 3100 3220

1000 2295 5750 1300 3350 3482

NS

1251/7203 cooling only

Air cooled chillers with axial fans and twin-rotor screw compressor Cooling capacity from 237 to 1595 kW

R134a

Aermec participate in the EUROVENT program:LCP/A/P/C, up to 600 kW the products are present on the site www.eurovent-certification.com * Not certified model

Characteristics
Available in 32 sizes Cooling only version Manufactured with refrigerant R134a Options for partial or total heat recovery High efficiency, low noise screw compressors with modulating capacity control from 40 to 100%. (25 to 100% with electronic expansion valve option) Pump assembly option (see Unit Configurator) that includes: - single pump, or one run plus one standby pump - two 25 litre expansion tanks. Standard Version (): - Operating limit up to 42 C external air temperature - Compressor acoustical enclosure for low noise operation. Version L: - Operating limit up to 42 C external air temperature - Compressor acoustical enclosure for low noise operation - Fan speed control - Hot gas discharge muffler. High efficiency Version A: - Operating limit up to 48 C external air temperature - Compressor acoustical enclosure for low noise operation. High efficiency Version E: - Operating limit up to 48 C (46 C for sizes 5402 to 5702) external air temperature - Compressor acoustical enclosure for low noise operation - Fan speed control - Hot gas discharge muffler. Modulating capacity control microprocessor system Multilingual display panel Shell and tube evaporator optimised for refrigerant R134a Axial fans for extremely quiet operation Compact sizes Metal control panel with anti-corrosion polyester paint

Accessories
AER485P1: RS-485 interface for supervision systems with MODBUS protocol. AVX: Spring anti-vibration mounts. For compatibility of the AVX mounts refer to the technical manual. DCPX: Low ambient device for cooling operation below 19 C down to -10 C. Standard for Versions D, L, and E. KRS: Evaporator trace heating. Factory fitted only. KRSDES/KRSREC: Evaporator and heat recovery exchangers trace heating. Factory fitted only. GP: Protective grille. Condenser coil external protection against accidental or hail damage. Factory fitted. PRV3: Remote control of the chiller operating functions. RIFNS: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted only. For compatibility of the RIF device refer to the technical manual. AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; AK: ACOUSTIC KIT (only for Versions L and E). This accessory allows further sound reduction. Must be requested at time of order and is available factory fitted only. MULTICHILLER: Control system for multiple parallel installed constant flow chillers providing individual chiller on/off and control capability.

200

Mod. NS AER485P1 MULTICHILLER AK-ACUSTIC KIT (1) PRV3 AERWEB300 Mod. NS AER485P1 MULTICHILLER AK-ACUSTIC KIT (1) PRV3 AERWEB300 Mod. NS /L GP 300M (1) GP 400M (1) GP 300B (1) GP 400B (1) GP 500B (2) GP 300M+300M (1) KRS (1) KRSDES (1) (2) KRSREC (1) (2)

1251 4(x1)
4 4 4 4

1401 4(x1)
4 4 4 4

1601 4(x1)
4 4 4 4

1801 4(x1)
4 4 4 4

2101 4(x1)
4 4 4 4

Accessory compatibility 2401 1402 1602 4(x1) 4(x2) 4(x2)


4 4 4 4 4 4 4 4 4 4 4 4

4(x2) 4 4 4 4

1802

4(x2) 4 4 4 4

2002

4(x2) 4 4 4 4

2202

4(x2) 4 4 4 4

2352

4(x2) 4 4 4 4

2502

4(x2) 4 4 4 4

2652

4(x2) 4 4 4 4

2802

4(x2) 4 4 4 4

3002

4(x2) 4 4 4 4

3202

4(x2) 4 4 4 4

3402

4(x2) 4 4 4 4

3602

4(x2) 4 4 4 4

3902

4(x2) 4 4 4 4

4202

4(x2) 4 4 4 4

4502

4(x2) 4 4 4 4

4802

4(x2) 4 4 4 4

5002

4(x2) 4 4 4 4

5202

4(x2) 4 4 4 4

5402

4(x2) 4 4 4 4

5702

4(x3) 4 4 4 4

6003

4(x3) 4 4 4 4

6303

4(x3) 4 4 4 4

6603

4(x3) 4 4 4 4

6903

4(x3) 4 4 4 4

7203

1251
4

1401
4

1601
4

1801
4

2101
4

2401
4

1402
4

1602
4

1802
4

2002

2202

2352

2502

2652

2802

3002

4 4 4

4 KRS10 KRS10 KRS10 KRS10 KRS11 KRS11 KRS10 KRS10 KRS10 KRS10 KRS10 KRS10 KRS10 KRS11 KRS11 KRS12 KRS10DES KRS10DES KRS10DES KRS10DES KRS11DES KRS11DES KRS18DES KRS18DES KRS18DES KRS18DES KRS18DES KRS18DES KRS18DES KRS19DES KRS19DES KRS12DES KRS10REC KRS10REC KRS10REC KRS10REC KRS11REC KRS11REC KRS10REC KRS10REC KRS10REC KRS10REC KRS10REC KRS10REC KRS10REC KRS11REC KRS11REC KRS12REC

Mod. NS /L (*) 3202 3402 3602 3902 4202 4502 4802 5002 5202 5402 5702 6003 6303 6603 6903 7203 4 4 GP 300M+300M (1) 4 4 4 GP 300M+400M (1) 4 4 GP 400M+400M (1) GP 400M+500M (1) 4 4 4 4 GP 500M+500M (1) 4 GP 300M+300M+400M (1) 4 4 GP 300M+400M+400M (1) 4 4 GP 400M+400M+400M (1) KRS12 KRS12 KRS12 KRS13 KRS13 KRS14 KRS14 KRS14 KRS14 KRS14 KRS14 KRS15 KRS16 KRS16 KRS17 KRS17 KRS (1) (1) (2) KRS12DES KRS12DES KRS12DES KRS13DES KRS13DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS15DES KRS16DES KRS16DES KRS17DES KRS17DES KRSDES KRS12REC KRS12REC KRS12REC KRS13REC KRS13REC KRS14REC KRS14REC KRS14REC KRS14REC KRS14REC KRS14REC KRS15REC KRS16REC KRS16REC KRS17REC KRS17REC KRSREC(1) (2) Mod. NS A/E (*) GP 300M (1) GP 400M (1) GP 500M (1) GP 300B (1) GP 400B (1) GP 500B (1) GP 300M+300M (1) KRS (1) KRSDES (1) (2) KRSREC (1) (2) 1251
4

1401
4

1601
4

1801
4

2101

2401
4

1402

1602

1802

2002

2202

2352

2502

2652

2802

3002

4 4 4 4 4 4 4 4
KRS10 KRS10 KRS11 KRS10 KRS11 KRS11 KRS11 KRS11 KRS10 KRS10 KRS11 KRS11 KRS11 KRS11 KRS11 KRS13 KRS10DES KRS10DES KRS11DES KRS10DES KRS11DES KRS11DES KRS19DES KRS19DES KRS18DES KRS18DES KRS19DES KRS19DES KRS19DES KRS19DES KRS19DES KRS13DES KRS10REC KRS10REC KRS11REC KRS10REC KRS11REC KRS11REC KRS11REC KRS11REC KRS10REC KRS10REC KRS11REC KRS11REC KRS11REC KRS11REC KRS11REC KRS13REC

Mod. NS A/E 3202 3402 3602 3902 4202 4502 4802 5002 5202 5402 5702 6003 6303 6603 6903 7203 GP 300M+300M (1) 4 (1) GP 300M+400M 4 GP 400M+400M (1) 4 (1) GP 400M+500M 4 4 GP 500M+500M (1) 4 4 4 4 4 4 GP 400M+400M+500M (1) 4 GP 400M+500M+500M (1) 4 4 GP 500M+500M+500M (1) 4 4 KRS14 KRS13 KRS12 KRS13 KRS13 KRS14 KRS14 KRS14 KRS14 KRS14 KRS14 KRS15 KRS16 KRS16 KRS17 KRS17 KRS (1) KRS14DES KRS13DES KRS12DES KRS13DES KRS13DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS15DES KRS16DES KRS16DES KRS17DES KRS17DES KRSDES (1) (2) KRS14REC KRS13REC KRS12REC KRS13REC KRS13REC KRS14REC KRS14REC KRS14REC KRS14REC KRS14REC KRS14REC KRS15REC KRS16REC KRS16REC KRS17REC KRS17REC KRSREC (1) (2) Mod. NS /L AVX RIFNS (1) Mod. NS /L AVX RIFNS (1) Mod. NS A/E AVX RIFNS (1) Mod. NS A/E AVX RIFNS (1) 1251 502 1251 3202 509 3202 1251 502 1251 3202 509 3202 1401 502 1401 3402 509 3402 1401 502 1401 3402 513 3402 1601 502 1601 3602 507 3602 1601 502 1601 3602 516 3602 1801 501 1801 3902 508 3902 1801 506 1801 3902 519 3902 2101 506 2101 4202 508 4202 2101 510 2101 4202 519 4202 2401 506 2401 4502 516 4502 2401 510 2401 4502 521 4502 1402 502 1402 4802 516 4802 1402 503 1402 4802 521 4802 1602 502 1602 5002 532 5002 1602 503 1602 5002 535 5002 1802 503 1802 5202 533 5202 1802 504 1802 5202 535 5202 2002 504 2002 5402 533 5402 2002 511 2002 5402 535 5402 2202 505 2202 5702 534 5702 2202 511 2202 5702 535 5702 2352 505 2352 6003 517 6003 2352 511 2352 6003 526 6003 2502 505 2502 6303 515 6303 2502 511 2502 6303 528 6303 2652 511 2602 6603 515 6603 2652 511 2602 6603 528 6603 2802 511 2802 6903 523 6903 2802 511 2802 6903 531 6903 3002 509 3002 7203 523 7203 3002 509 3002 7203 531 7203

Note: (1) Accessory only factory fitted (2) Accessory KRSDES/KRSREC includes evaporator and heat recovery exchangers trace heating

201

Mod. NS DCPX (3) Mod. NS DCPX (3) Mod. NS A DCPX (3) Mod. NS A DCPX (3)

1251 65(x1) 3202 68(x1) 1251 65(x1) 3202 68(x1)

1401 65(x1) 3402 68(x1) 1401 65(x1) 3402 72(x1)

1601 65(x1) 3602 68(x1) 1601 65(x1) 3602 73(x1)

1801 65(x1) 3902 72(x1) 1801 69(x1) 3902 73(x1)

2101 69(x1) 4202 72(x1) 2101 69(x1) 4202 73(x1)

COMPATIBILITY DCPX 2401 1402 1602 69(x1) 68(x1) 68(x1) 4502 4802 5002 73(x1) 73(x1) 73(x1) 2401 69(x1) 4502 73(x1) 1402 68(x1) 4802 73(x1) 1602 68(x1) 5002 73(x1)

1802 68(x1) 5202 73(x1) 1802 68(x1) 5202 73(x1)

2002 68(x1) 5402 73(x1) 2002 68(x1) 5402 73(x1)

2202 68(x1) 5702 73(x1) 2202 68(x1) 5702 73(x1)

2352 68(x1) 6003 68+76 2352 68(x1) 6003 73+76

2502 68(x1) 6303 72+76 2502 68(x1) 6303 73+76

2652 68(x1) 6603 72+76 2652 68(x1) 6603 73+76

2802 68(x1) 6903 73+76 2802 68(x1) 6903 73+76

3002 68(x1) 7203 73+76 3002 68(x1) 7203 73+76

DCPX VERSION WITH HIGH STATIC PRESSURE FANS Mod. NS DCPX (3) Mod. NS DCPX (3) Mod. NS A DCPX (3) Mod. NS A DCPX (3) 1251 69(x1) 3202 73(x1) 1251 69(x1) 3202 73(x1) 1401 69(x1) 3402 73(x1) 1401 69(x1) 3402 73(x1) 1601 69(x1) 3602 73(x1) 1601 69(x1) 3602 73(x1) 1801 69(x1) 3902 73(x1) 1801 69(x1) 3902 74(x1) 2101 69(x1) 4202 73(x1) 2101 70(x1) 4202 74(x1) 2401 69(x1) 4502 73(x1) 2401 70(x1) 4502 75(x1) 1402 68(x1) 4802 73(x1) 1402 68(x1) 4802 75(x1) 1602 68(x1) 5002 73(x1) 1602 68(x1) 5002 75(x1) 1802 68(x1) 5202 73(x1) 1802 68(x1) 5202 75(x1) 2002 68(x1) 5402 74(x1) 2002 73(x1) 5402 75(x1) 2202 68(x1) 5702 75(x1) 2202 73(x1) 5702 75(x1) 2352 68(x1) 6003 73+76 2352 73(x1) 6003 73+77 2502 68(x1) 6303 73+76 2502 73(x1) 6303 74+77 2652 68(x1) 6603 73+76 2652 73(x1) 6603 74+77 2802 68(x1) 6903 73+76 2802 73(x1) 6903 75+77 3002 73(x1) 7203 73+76 3002 73(x1) 7203 75+77

Accessory supplied as standard on Versions L, E, and D The number in brackets e.g. (x3) indicates the quantity.
(3)

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system requirements. Configuration fields: 12 3 4 5 6 7 8 9 10 11 12 13 14 15 | | | | | | | | | | Code | Expansion device | Heat recovery | Condenser coil | Power supply | | | | | | Size Model Version Fan Pump Code: NS Size: 1251, 1401, 1601, 1801, 2101, 2401, 1402, 1602, 1802, 2002, 2202 2352, 2502, 2652, 2802,3002, 3202,3402, 3602, 3902,4202,4502, 4802, 5002, 5202, 5402, 5702, 6003, 6303, 6603, 6903, 7203 Expansion device: - R134a thermostatic expansion valve, minimum leaving water temperature down to +4C Y - R134a thermostatic expansion valve, minimum leaving liquid temperature down to -6 C X - R134a electronic expansion valve, minimum leaving liquid temperature down to -6 C Model: - Cooling only, heat exchanger to PED regulations C - Condensing unit Heat recovery: - Without heat recovery D - With desuperheaters (partial heat recovery) T - With total heat recovery Version: - Standard L - Standard low noise version A - High efficiency E - High efficiency low noise version Condenser coil: - Aluminium R - Copper Attention: the standard options are shown by the symbol options D - T - C are not compatible with option Y 500V 3~50Hz power supply is compatible only with high static pressure fans option (M) sizes 5002-5202-5402-5702 are available only with electronic expansion valve (X) Example of the configuration fields: NS1401LR8PA This is an NS unit with of size 1401, standard low noise version, with copper condenser coil, power supply 400V 3~ 50Hz with circuit S - Tinned copper V - Anti-corrosion coated aluminium Fan: - Standard M - High static pressure J - Inverter Power supply: - 400V 3~ 50Hz with fuses 2 - 230V 3~ 50Hz with fuses * 4 - 230V 3~ 50Hz with circuit breakers * *(not available for sizes: 1251~2401, 2352~7203) 5 - 500V 3~ 50Hz with fuses ** 8 - 400V 3~ 50Hz with circuit breakers 9 - 500V 3~ 50Hz with circuit breakers ** ** (not available for sizes: 1801~2401, 3402~7203) Pump: 00 - Without pump assembly PA - Pump assembly (Pump A) PB - Pump assembly (Pump A and standby pump) PC - Pump assembly (Pump C) PD - Pump assembly (Pump C and standby pump) PE - Pump assembly (Pump E) PF - Pump assembly (Pump E and standby pump) PG - Pump assembly (Pump G) PH - Pump assembly (Pump G and standby pump) PJ - Pump assembly (Pump J) PK - Pump assembly (Pump J and standby pump) breakers, and pump assembly with only pump A. Since each option is uniquely identified it is not neccessary to indicate the standard options (represented by ) in the unit configurator.

202

Technical Data
Mod. NS Cooling capacity U.M. kW Vers. L A E L A E L A E L A E L A E L A E L A E -L A-E -L A-E All L A E -L A-E L A E L A E 1251 258 237 275 251 91.97 97.82 89.08 90.90 44548 40936 47472 43344 42.00 35.00 45.00 38.00 2.81 2.42 3.09 2.76 3,81 3,70 4,22 4,09 159 162 154 152 236 236 381 381 1 116000 82000 110000 70000 6 6 94 86 94 86 62 54 62 54 1401 293 264 313 290 109.12 113.90 98.07 101.90 50568 45580 54008 50052 44.00 36.00 39.00 33.00 2.68 2.32 3.19 2.85 3,75 3,64 4,24 4,11 187 192 172 170 236 236 425 425 1 116000 82000 106000 74000 6 6 95 87 95 87 63 55 63 55 1601 335 307 346 329 118.28 125.03 104.84 109.77 57792 52976 59684 56760 45.00 38.00 25.00 23.00 2.83 2.46 3.30 3.00 3,70 3,59 4,30 4,17 197 206 181 182 236 236 425 425 1 110000 82000 106000 81500 6 6 97 89 97 89 65 57 65 57 1801 383 360 419 390 146.77 151.51 135.54 141.29 66220 62092 72240 67252 58.00 51.00 45.00 39.00 2.61 2.37 3.09 2.76 3,73 3,62 4,24 4,11 238 244 222 225 331 338 486 493 1 110000 82000 136000 94000 6 8 97 89 97 89 65 57 65 57 2101 442 411 465 431 167.37 171.14 151.46 156.22 76196 70864 80152 74304 37.00 32.00 38.00 33.00 2.64 2.40 3.07 2.76 3,78 3,67 4,20 4,07 280 284 256 255 348 355 614 621 1 150000 110000 180000 113000 8 10 98 90 98 90 66 58 66 58 2401 491 453 531 495 181.70 186.36 166.96 173.64 84796 78088 91676 85484 43.00 36.00 47.00 41.00 2.70 2.43 3.18 2.85 3,76 3,65 4,28 4,15 301 307 279 283 388 395 678 685 1 145000 104000 174000 118000 8 10 98 90 98 90 66 58 66 58 1402 281 258 303 272 102.98 106.84 97.87 101.70 48504 44548 52288 46956 39.0 33.0 30.0 24.0 2.73 2.42 3.10 2.68 3,88 3,76 4,20 4,07 177 180 171 170 269 269 245 245 2 116000 82000 106000 74000 6 6 96 88 96 88 64 56 64 56 1602 316 286 344 313 122.26 125.99 110.16 115.93 54524 49364 59340 54008 47.0 39.0 39.0 32.0 2.58 2.27 3.12 2.70 3,72 3,61 4,22 4,09 207 212 190 194 309 309 283 283 2 116000 82000 106000 77000 6 6 97 89 97 89 65 57 65 57

Total input power

kW

Water flow rate

l/h

Pressure drop

kPa

EER

W/W

ESEER

Total input current Maximum current (LRA) Starting current (FLA) Compressors Fan air flow rate Number of fans Sound power

A A A n (m3/h)

dB(A)

Sound pressure

dB(A)

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011

Power supply = 400V 3~ 50Hz. Performance values refer to the following conditions: Sound power Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744) Cooling: - - - - entering water temperature 12 C leaving water temperature 7 C external air temperature 35 C t = 5 K.

203

Technical Data
Mod. NS Cooling capacity U.M. kW Vers. L A E L A E L A E L A E L A E L A E L A E -L A-E -L A-E All L A E -L A-E L A E L A E 1802 357 324 396 363 139.55 143.22 128.19 130.95 61576 55900 68284 62608 53.0 44.0 35.0 29.0 2.55 2.26 3.09 2.77 3,69 3,58 4,20 4,07 218 221 215 214 345 352 325 332 2 110000 82000 144000 96000 6 8 97 89 97 89 65 57 65 57 2002 403 371 448 409 155.24 161.02 145.60 151.28 69488 63984 77400 70520 36.0 31.0 44.0 37.0 2.59 2.30 3.08 2.70 3,59 3,48 4,23 4,10 261 266 248 247 372 379 403 410 2 145000 104000 187500 124500 8 10 98 90 98 90 66 58 66 58 2202 449 419 493 452 172.32 182.25 158.57 162.27 77400 72240 85140 77916 35.0 35.0 39.0 33.0 2.60 2.30 3.11 2.78 3,56 3,45 4,24 4,11 295 301 274 277 392 399 420 427 2 145000 104000 180000 120000 8 10 98 90 98 90 66 58 66 58 2352 484 442 517 477 178.84 186.46 167.74 172.42 83592 76196 89268 82216 48.0 40.0 42.0 36.0 2.71 2.37 3.08 2.76 3,82 3,71 4,23 4,10 306 310 288 290 425 432 480 487 2 145000 104000 176500 123000 8 10 97 90 97 90 65 58 65 58 2502 501 457 541 501 188.96 199.57 174.95 182.59 86516 78948 93396 86516 50.0 42.0 46.0 39.0 2.65 2.29 3.09 2.75 3,81 3,70 4,25 4,12 322 333 301 303 458 465 507 514 2 145000 104000 173000 126000 8 10 98 90 98 90 66 58 66 58 2652 539 493 575 537 203.98 212.57 184.13 193.80 93052 85140 99244 92708 47.0 39.0 48.0 42.0 2.64 2.32 3.12 2.77 3,73 3,62 4,25 4,12 347 354 320 320 458 465 551 558 2 152000 108000 173000 130000 8 10 98 90 98 90 66 59 66 58 2802 576 528 *610 572 218.32 231.88 199.52 209.12 99416 91160 105264 98728 53.0 45.0 55.0 48.0 2.64 2.28 3.05 2.73 3,78 3,67 4,21 4,08 371 381 339 344 458 465 553 560 2 152000 108000 173000 136000 8 10 98 91 98 91 66 59 66 59 3002 *627 571 *659 *621 227.13 238.70 202.70 211.44 108188 98556 113692 106984 44.0 37.0 32.0 28.0 2.76 2.39 3.25 2.93 3,68 3,57 4,28 4,15 384 398 353 352 472 472 567 567 2 226000 164000 212000 155500 12 12 99 90 99 90 66 57 66 57

Total input power

kW

Water flow rate

l/h

Pressure drop

kPa

EER

W/W

ESEER

Total input current Maximum current (LRA) Starting current (FLA) Compressors Fan air flow rate Number of fans Sound power

A A A n (m3/h)

dB(A)

Sound pressure

dB(A)

Data declared in accordance with UNI EN 14511:2011

* Not certified model EUROVENT

Power supply = 400V 3~ 50Hz. Performance values refer to the following conditions: Sound power Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Cooling: - - - - entering water temperature 12 C leaving water temperature 7 C external air temperature 35 C t = 5 K.

204

Technical Data
Mod. NS Cooling capacity U.M. kW Vers. L A E L A E L A E L A E L A E L A E L A E -L A-E -L A-E All L A E -L A-E L A E L A E *3202 669 614 694 659 236.99 249.60 209.44 219.28 115412 105952 119540 113520 38.0 32.0 25.0 23.0 2.82 2.46 3.31 3.00 3,68 3,57 4,30 4,17 394 411 362 364 472 472 567 567 2 220000 164000 212000 163000 12 12 99 91 99 91 66 58 66 58 *3402 718 667 765 719 264.67 276.20 240.08 250.78 124012 115068 131924 124012 50.0 43.0 35.0 31.0 2.71 2.41 3.19 2.87 3,68 3,57 4,26 4,13 435 450 403 407 567 574 628 635 2 220000 164000 242000 175500 12 14 99 91 99 91 66 58 66 58 *3602 768 719 836 780 293.21 302.72 270.78 282.31 132612 124184 144308 134504 58.0 51.0 45.0 39.0 2.62 2.38 3.09 2.76 3,68 3,57 4,19 4,06 477 488 444 450 662 676 654 661 2 220000 164000 272000 188000 12 16 99 92 99 92 66 59 66 59 *3902 825 771 882 820 313.80 322.34 286.68 297.20 142416 132956 152220 141384 46.0 40.0 41.0 35.0 2.63 2.39 3.08 2.76 3,73 3,62 4,18 4,05 519 527 478 480 679 693 778 792 2 260000 192000 316000 207000 14 18 100 92 100 92 67 59 67 59 *4202 876 812 950 885 327.16 337.61 301.16 314.64 151188 140180 163916 152736 50.0 43.0 46.0 40.0 2.68 2.41 3.15 2.81 3,73 3,62 4,24 4,11 540 551 501 508 719 733 825 839 2 255000 186000 310000 212000 14 18 100 92 100 92 67 59 67 59 *4502 933 864 996 925 347.76 357.25 317.10 329.56 160992 148952 171828 159616 40.0 34.0 43.0 37.0 2.68 2.42 3.14 2.81 3,73 3,62 4,17 4,04 582 591 535 538 736 750 900 914 2 295000 214000 354000 231000 16 20 100 92 100 92 67 59 67 59 *4802 984 905 1063 991 362.07 372.45 332.54 346.97 169764 156004 183352 170968 43.0 36.0 47.0 41.0 2.72 2.43 3.19 2.86 3,67 3,56 4,17 4,04 603 613 558 566 776 790 900 914 2 290000 208000 348000 236000 16 20 100 92 100 92 67 59 67 59 *5002 1060 982 1152 1085 393.08 407.50 363.45 378.93 182836 169248 198660 187136 40.0 34.0 42.0 37.0 2.70 2.41 3.17 2.86 3,71 3,60 4,25 4,12 648 670 614 626 866 880 1051 1065 2 297000 212000 346000 254000 16 20 101 93 101 93 68 60 68 60

Total input power

kW

Water flow rate

l/h

Pressure drop

kPa

EER

W/W

ESEER

Total input current Maximum current (LRA) Starting current (FLA) Compressors Fan air flow rate Number of fans Sound power

A A A n (m3/h)

dB(A)

Sound pressure

dB(A)

* Not certified model EUROVENT

Power supply = 400V 3~ 50Hz. Performance values refer to the following conditions: Sound power Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Cooling: - - - - entering water temperature 12 C leaving water temperature 7 C external air temperature 35 C t = 5 K.

203

Technical Data
Mod. NS Cooling capacity U.M. kW Vers. L A E L A E L A E L A E L A E L A E L A E -L A-E -L A-E All L A E -L A-E L A E L A E *5202 1137 1058 1241 1157 422.98 442.47 393.29 409.74 196080 182320 213968 199520 36 31 37 32 2.69 2.39 3.15 2.82 3,71 3,60 4,26 4,13 693 726 655 670 924 938 1109 1123 2 304000 216000 346000 272000 16 20 101 93 101 93 68 60 68 60 *5402 1182 1102 1283 1195 435.31 456.77 411.55 428.96 203820 190060 221364 206056 39 34 39 34 2.71 2.41 3.12 2.79 3,69 3,58 4,20 4,07 715 750 685 700 968 975 1228 1235 2 324000 240000 346000 283500 18 20 101 93 101 93 68 60 68 60 *5702 1226 1147 1326 1233 447.64 470.08 429.89 447.20 211560 197800 228760 212592 42 37 42 36 2.74 2.44 3.08 2.76 3,69 3,58 4,15 4,03 736 774 715 735 1012 1012 1227 1227 2 360000 267000 346000 295000 20 20 101 93 101 93 68 60 68 60 *6003 1259 1172 1368 1274 473.56 488.79 436.25 455.53 217408 202272 235984 219816 53 46 45 39 2.66 2.40 3.14 2.80 3,76 3,65 4,28 4,15 778 795 723 733 1050 1071 1013 1034 3 365000 268000 446000 306000 20 26 101 93 101 93 68 60 68 60 *6303 1317 1224 1415 1316 494.19 508.48 452.20 470.46 227212 211044 244068 226868 46 40 43 37 2.66 2.41 3.13 2.80 3,78 3,67 4,25 4,12 820 834 757 763 1067 1088 1072 1093 3 405000 296000 490000 325000 22 28 101 93 101 93 68 60 68 60 *6603 1368 1264 1481 1380 508.49 523.66 467.64 487.86 235984 218096 255592 238048 48 41 46 40 2.69 2.41 3.17 2.83 3,76 3,65 4,28 4,15 841 858 780 791 1107 1128 1064 1085 3 400000 290000 484000 330000 22 28 101 93 101 93 68 60 68 60 *6903 1426 1316 1527 1421 529.06 543.30 483.58 502.79 245960 226868 263504 245100 41 35 44 38 2.70 2.42 3.16 2.83 3,81 3,70 4,29 4,16 883 898 814 821 1124 1145 1122 1143 3 440000 318000 528000 349000 24 30 102 93 102 93 69 60 68 59 *7203 1476 1358 1595 1486 543.36 558.48 499.04 520.21 254560 234092 275200 256280 43 36 47 41 2.72 2.43 3.20 2.86 3,76 3,65 4,28 4,15 904 921 837 849 1164 1185 1122 1143 3 435000 312000 522000 354000 24 30 102 94 102 94 68 61 68 60

Total input power

kW

Water flow rate

l/h

Pressure drop

kPa

EER

W/W

ESEER

Total input current Maximum current (LRA) Starting current (FLA) Compressors Fan air flow rate Number of fans Sound power

A A A n (m3/h)

dB

Sound pressure

dB

* Not certified model EUROVENT

Power supply = 400V 3~ 50Hz. Performance values refer to the following conditions: Sound power Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Cooling: - - - - entering water temperature 12 C leaving water temperature 7 C external air temperature 35 C t = 5 K.

206

Dimensions (mm)

Mod. NS Height Width Length Weight empty Mod. NS Height Width Length Weight empty Mod. NS Height Width Length Weight empty Mod. NS Height Width Length Weight empty

(A) (B) (C) kg (A) (B) (C) kg (A) (B) (C) kg (A) (B) (C) kg

Version All All /L A/E /L A/E Version All All /L A/E /L A/E Version All All /L A/E /L A/E Version All All /L A/E /L A/E

1251 2450 2200 3780 3780 2910 3050 1802 2450 2200 3780 4770 3460 3900 3202 2450 2200 7160 7160 6270 6520 5202 2450 2200 11100 11100 10100 10750

1401 2450 2200 3780 3780 3060 3230 2002 2450 2200 4770 5750 4270 4700 3402 2450 2200 7160 8150 6770 7540 5402 2450 2200 11100 11100 10200 10800

1601 2450 2200 3780 3780 3150 3250 2202 2450 2200 4770 5750 4740 5270 3602 2450 2200 7160 9140 7280 8610 5702 2450 2200 11100 11100 10350 10850

1801 2450 2200 3780 4770 3650 4330 2352 2450 2200 4770 5750 4800 5390 3902 2450 2200 8150 10120 7830 9180 6003 2450 2200 11530 14490 11390 13760

2101 2450 2.200 4770 5750 4230 4920 2502 2450 2200 4770 5750 4900 5500 4202 2450 2200 8150 10120 8180 9410 6303 2450 2200 12520 15470 12210 14330

2401 2450 2200 4770 5750 4570 5150 2652 2450 2200 5750 5750 5320 5510 4502 2450 2200 9140 11100 8750 9820 6603 2450 2200 12520 15470 12250 14560

1402 2450 2200 3780 3780 3250 3420 2802 2450 2200 5750 5750 5330 5520 4802 2450 2200 9140 11100 9090 10200 6903 2450 2200 13510 16450 13230 14970

1602 2450 2200 3780 3780 3270 3560 3002 2450 2200 7160 7160 6180 6450 5002 2450 2200 10120 11100 9360 10450 7203 2450 2200 13510 16450 13570 15350

For transport reasons Versions A and E, sizes 6003 to 7203, are shipped separated; one module consisting of two compressors and standard electrical panel (placed in front of the unit) and one module with one compressor and the electrical panel placed on the

compressor side beneath the condenser coil. On the site it is only necessary to connect the two sections electrically. For more information refer to the technical and/or installation manual.

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

207

Cod.: SNSUY.06 / 1302

NSH
1251/3602 heat pump

Air cooled heat pumps with axial fans and twin-rotor screw compressor Cooling capacity from 235 to 730 kW - Heating capacity from 276 to 789 kW

AERMEC partecipates in the EUROVENT programme for:LCP/A/P/R up to 600 kW Check ongoing validity of certificate online: www.eurovent-certification.com

Characteristics
R134a refrigerant High efficiency both in cooling and heating mode, and also at part load Compact sizes Screw compressors with 40-100% modulating capacity control, with acoustical enclosure as a standard Shell and tube heat exchanger optimised as either evaporator or condenser Electronic expansion valve as a standard Economiser circuit with plate heat exchanger for improved performance, particularly at high compression ratios, as experienced in heating mode at low ambients Generously sized refrigerant circuit for minimum pressure drop Modulating capacity control microprocessor system with multilingual display panel Extremely robust construction with anti-corrosion polyester paint Extensive choice of models and versions - 17 sizes (4 single, 13 double circuit) - 4 versions: standard [], low noise[L], high efficiency [A], low noise high efficiency [E] - Partial heat recovery option (desuperheater) - Pump assembly option (single pump and expansion vessel) - Inverter fans with high static pressure option - Condenser coil with aluminium, coated aluminium, copper or tinned copper fins Wide operating limits - Maximum leaving water temperature in heating mode 55C - Maximum external air temperature in cooling mode 48 C for high efficiency versions, 44 C for standard versions - Minimum external temperature in heating mode -7 C for high efficiency versions, -3 C for standard versions - Ability to exceed operating limits with a reduction of capacity using an intelligent algorithm that avoids a fault trip-out - Low sound level - Low noise axial fans with aerodynamic profile blades - Acoustical compressor enclosure as standard - For low noise versions: - Hot gas discharge muffler - Reduced fan speed by means of phase-cut controller (DCPX) - Optional acoustic kit AK, including enhanced soundproofing enclosures and additional insulation

Accessories
AER485P1: RS-485 interface for supervision ing functions. remote control max. 6 units in RS485 netsystems with MODBUS protocol. RIFNSH: Power factor correction. Connected in work with integrated GPRS modem; AVX: Spring anti-vibration mounts. For comparallel to the motor allowing about 10% AERWEB300-18G: Web server to monitor and patibility of the AVX mounts refer to the techreduction of input current. Must be requested remote control max. 18 units in RS485 netnical manual. at time of order and is available factory fitted work with integrated GPRS modem; DCPX: Electronic controller that varies fan only. For compatibility of the RIF device refer AK: ACOUSTIC KIT (only for Versions speed based on condensing pressure. Low to the technical manual. HL-HE). ambient device for cooling operation below AERWEB300: Accessory AERWEB allows This accessory allows further sound reduc19 C down to -10 C. Standard for Versions remote control of a chiller through a comtion. Must be requested at time of order and HD, HL, and HE. mon PC and an ethernet connection over a is available factory fitted only. KRS: Evaporator trace heating. Factory fitted common browser; 4 versions available: MULTICHILLER: Control system for multiple only. AERWEB300-6: Web server to monitor and parallel installed constant flow chillers pro KRSDES: E vaporator and desuperheater remote control max. 6 units in RS485 netviding individual chiller on/off and control exchangers trace heating. Factory fitted only. work; capability. GP: Protective grille. Condenser coil external AERWEB300-18: Web server to monitor and protection against accidental or hail damage. remote control max. 18 units in RS485 netFactory fitted. work; PRV3: Remote control of the chiller operatAERWEB300-6G: Web server to monitor and

208

Accessory Compatibility
Mod. NSH AER485P1 MULTICHILLER AK-ACUSTIC KIT (1) PRV3 AERWEB300 Mod. NSH KRS (1) KRSDES (1)(2) Mod. NSH RIFNSH Mod. NSH GP300M (1) GP400M (1) GP300B (1) GP400B (1) GP500B (1) Mod.NSH DCPX(3)(4) Mod.NSH(version - L) AVX (00) AVX (PA) AVX (PC) AVX (PE) AVX (PG) AVX (PJ) Mod.NSH(version A - E) AVX (00) AVX (PA) AVX (PC) AVX (PE) AVX (PG) AVX (PJ) Accessories available for all versions (1)Accessory only factory fitted (2)Accessory KRSDES includes evaporator and desuperheater heat exchangers trace heating (3) Standard for low noise Versions(L/E) and with desuperheater(D) (4)Fans Inverter (J): DCPX not necessary. Fans are already equipped with speed controller Mod. NSH AER485P1 MULTICHILLER AK-ACUSTIC KIT (1) PRV3 AERWEB30 Mod. NSH KRS (1) KRSDES (1)(2) Mod. NS RIFNSH Mod. NSH GP500B (1) GP300M+300M (1) GP300M+400M (1) GP400M+400M (1) Mod.NSH DCPX(3)(4) Mod.NSH (version - L) AVX(00) AVX(PA) AVX(PC) AVX(PE) AVX(PG) AVX(PJ) Mod.NSH(version A - E) AVX(00) AVX(PA) AVX(PC) AVX(PE) AVX(PG) AVX(PJ) Accessories available for all versions (1)Accessory only factory fitted (2)Accessory KRSDES includes evaporator and desuperheater heat exchangers trace heating (3) Standard for low noise Versions(L/E) and with desuperheater(D) (4)Fans Inverter (J): DCPX not necessary. Fans are already equipped with speed controller 2202 (x2) 2202 KRS19 KRS19DES 2202 2202 2202 2352 (x2) 2352 KRS19 KRS19DES 2352 2352 2352 2502 (x2) 2502 KRS19 KRS19DES 2502 2502 2502 2652 (x2) 2652 KRS19 KRS19DES 2652 2652 2652 2802 (x2) 2802 KRS19 KRS19DES 2802 2802 2802 3002 (x2) 3002 KRS14 KRS14DES 3002 3002 3002 3202 (x1) 3202 KRS14 KRS14DES 3202 3202 3202 2202 DCPX73 2202 544 544 544 544 544 544 2202 543 543 543 543 543 543 2352 DCPX73 2352 545 546 546 546 546 546 2352 545 545 545 545 545 545 2502 DCPX73 2502 547 547 547 547 548 548 2502 549 550 550 550 550 550 2652 DCPX73 2652 549 549 549 549 550 550 2652 551 551 551 551 551 551 2802 DCPX73 2802 549 550 550 550 550 550 2802 551 551 551 551 551 551 3002 DCPX73 3002 552 553 553 553 553 553 3002 554 553 553 553 553 553 3202 DCPX73 3202 552 553 555 555 555 555 3202 556 553 555 555 555 555 3402 DCPX73 3402 557 557 557 557 557 557 3402 557 557 557 557 557 557 3602 DCPX73 3602 558 558 558 558 558 558 3602 559 559 559 559 559 559 3402 (x1) 3402 KRS14 KRS14DES 3402 3402 3402 3602 (x1) 3602 KRS14 KRS14DES 3602 3602 3602 1251 (x1) 1251 KRS11 KRS11DES 1251 1251 1251 1401 (x1) 1401 KRS11 KRS11DES 1401 1401 1401 1601 (x1) 1601 KRS11 KRS11DES 1601 1601 1601 1801 (x1) 1801 KRS11 KRS11DES 1801 1801 1801 1251 DCPX69 1251 536 536 536 536 536 536 1251 536 536 536 536 536 536 1401 DCPX69 1401 536 536 536 536 536 536 1401 536 536 536 536 536 536 1601 DCPX69 1601 536 536 536 536 536 536 1601 536 536 536 536 536 536 1801 DCPX69 1801 539 539 540 540 540 540 1801 540 540 540 540 540 540 1402 DCPX68 1402 537 537 537 537 538 538 1402 537 537 538 538 538 538 1602 DCPX68 1602 538 538 538 538 538 538 1602 538 538 538 538 538 538 1802 DCPX68 1802 541 541 541 541 541 541 1802 541 541 541 541 541 541 2002 DCPX73 2002 542 543 543 543 543 543 2002 543 543 543 543 543 543 1402 (x2) 1402 KRS19 KRS19DES 1402 1402 1402 1602 (x2) 1602 KRS19 KRS19DES 1602 1602 1602 1802 (x2) 1802 KRS19 KRS19DES 1802 1802 1802 2002 (x2) 2002 KRS19 KRS19DES 2002 2002 2002

209

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system requirements.

Configuration fields: 12 3 4 5 6 7 8 9 10 11 12 13 14 15 | | | | | | | | | | Code | Expansion device | Heat | Condenser coil | Power supply | | | Recovery | | | Size Model Version Fan Pump

Code: NS Size: 1251, 1401, 1601, 1801, 1402, 1602, 1802, 2002, 2202 2352, 2502, 2652, 2802,3002, 3202,3402, 3602 Expansion device: X - Electronic thermostatic valve, max. temp. of water produced: +4C (for lower temperatures please contact us) Model: H

Condenser coil: - Aluminium R - Copper S - Tinned copper V - Anti-corrosion coated aluminium Fan: - Standard J - Inverter Power supply: - 400V 3~ 50Hz with fuses 2 - 230V 3~ 50Hz with fuses * 4 - 230V 3~ 50Hz with circuit breakers * * (available for sizes 1402,1602,1802,2002,2202) 5 - 500V 3~ 50Hz with fuses ** 8 - 400V 3~ 50Hz with circuit breakers 9 - 500V 3~ 50Hz with circuit breakers ** ** (not available for sizes 1801, 3402, 3602) Pump: 00 - Without pump assembly PA - Pump assembly (Pump A) PC - Pump assembly (Pump C) PE - Pump assembly (pump E) PG - Pump assembly (Pump G) PJ - Pump assembly (Pump J) Example of the configuration fields: NS1401XH00 This is an NS unit, size 1401, electronic expansion valve, heat pump model, without heat recovery, standard version with aluminium condenser coils, standard fans, 400V 3~50Hz power supply with fuse, without pump assembly

- Heat pump

Heat recovery: - Without heat recovery D - With desuperheaters Version: L A E Standard Standard low noise version High efficiency High efficiency low noise version

Attention: The standard options are marked with the symbol

210

Technical Data
NSH U.M. VERS. H Cooling capacity kW HL HA HE H Total input power kW HL HA HE H Water flow rate evaporator l/h HL HA HE H Pressure drop evaporator kPa HL HA HE Heating capacity Total input power Water flow rate condenser Pressure drop condenser EFFICIENCIES H EER W/W HL HA HE COP W/W H/HL HA/HE H ESEER W/W HL HA HE ELECTRICAL DATA Power supply H Input current (COOLING MODE) A HL HA HE Input current (HEATING MODE) Maximum current (FLA) Starting current (LRA) A A A H/HL HA/HE H/HL HA/HE H/HL HA/HE 157 166 149 161 159 150 209 209 327 327 174 185 164 178 171 163 242 242 387 387 189 204 185 202 189 180 258 258 431 431 400V 3~ 50Hz 226 242 215 234 218 212 316 316 472 472 173 182 168 181 173 165 276 276 251 251 192 207 186 202 193 182 276 276 251 251 225 241 216 233 223 213 325 325 305 305 232 245 227 246 242 229 352 352 313 313 2,66 2,48 3,01 2,73 2,97 3,20 3,15 3,09 3,51 3,36 2,59 2,37 2,96 2,61 2,95 3,17 3,04 2,94 3,44 3,21 2,67 2,40 2,87 2,52 3,03 3,20 3,14 2,97 3,31 3,09 2,61 2,38 2,84 2,52 2,94 3,12 3,07 2,96 3,30 3,10 2,47 2,26 2,71 2,40 2,79 3,03 3,02 2,90 3,23 3,05 2,66 2,40 2,90 2,59 3,01 3,22 3,25 3,07 3,48 3,29 2,61 2,37 2,91 2,64 2,95 3,21 3,18 3,05 3,49 3,33 2,70 2,56 2,89 2,61 2,88 3,09 3,29 3,27 3,48 3,30 kW kW l/h kPa H/HL HA/HE H/HL HA/HE H/HL HA/HE H/HL HA/HE 1251 244 235 262 250 91,82 94,77 86,93 91,80 42140 40592 45236 43172 34 32 38 32 276 282 93,08 88,07 47300 48332 45 47 1401 260 250 281 266 100,70 105,64 95,02 101,92 44892 43172 48504 45924 25 23 41 37 292 298 98,90 94,16 50052 51084 33 49 1601 296 280 309 291 111,02 116,92 107,82 115,73 51084 48332 53320 50224 39 35 27 24 337 333 111,37 103,94 57792 57104 53 33 1801 353 335 365 343 135,00 140,94 128,32 136,13 60888 57792 62952 59168 32 30 43 38 382 395 130,21 126,59 65532 67596 40 54 1402 241 227 257 242 97,80 100,72 94,88 100,80 41624 39216 44376 41796 33 30 36 33 273 282 97,99 93,07 46784 48332 44 47 1602 298 285 315 301 111,90 118,84 108,33 116,19 51428 49192 54352 51944 32 30 50 46 341 344 113,21 106,63 58480 58824 45 64 1802 342 327 365 349 131,18 138,06 125,32 132,17 58996 56416 62952 60200 40 37 43 39 381 397 129,50 123,60 65360 67940 52 54 2002 366 354 384 366 135,38 138,29 132,49 140,32 63124 61060 66220 63124 45 43 47 43 412 414 142,80 133,76 70520 70864 60 58

data in accordance with ISO EN 14511:2011 NOMINALCONDITIONS: Cooling mode entering water temperature 12 C leaving water temperature 7 C external air temperature 35 C t = 5 K. Heating mode entering water temperature 40 C leaving water temperature 45 C external air temperature 7 C t = 5 K.

211

Technical data
NSH COMPRESSOR N compressors/circuits FAN H Air flow rate m/h HL HA HE H Total input power kW HL HA HE H Total input current A HL HA HE H Quantity n HL HA HE SHELL & TUBE HEAT EXCHANGER Water contents Water connections Quantity dm3 n dm3 n dm3 n H/HL H/HL H/HL 103,8 101,2 98,0 138,2 6 1 103,8 101,2 143,4 143,4 128400 89880 117600 82320 10,5 7,2 10,5 7,2 22,2 22,2 22,2 22,2 6 6 6 6 128400 89880 117600 117600 10,5 7,2 10,5 7,2 22,2 22,2 22,2 22,2 6 6 6 6 120000 84000 112200 78540 10,5 7,2 10,5 7,2 22,2 22,2 22,2 22,2 6 6 6 6 n/n 1/1 1/1 1/1 U.M. VERS. 1251 1401 1601 1801 1402 1602 1802 2002

TWIN-ROTOR SCREW 1/1 2/2 2/2 2/2 2/2

(STANDARD) 171200 119840 156000 109200 14 9,6 14,0 9,6 29,6 29,6 29,6 29,6 8 8 8 8 128400 89880 117600 82320 10,5 7,2 10,5 7,2 22,2 22,2 22,2 22,2 6 6 6 6 120000 84000 112200 78540 10,5 7,2 10,5 7,2 22,2 22,2 22,2 22,2 6 6 6 6 171200 119840 153200 107240 14 9,6 14,0 9,6 29,6 29,6 29,6 29,6 8 8 8 8 214000 149800 196000 137200 17,5 12 17,5 12 37,0 37,0 37,0 37,0 10 10 10 10

SHELL & TUBE HEAT EXCHANGER Water contents Water connections Quantity EXPANSION VESSEL Capacity Quantity SOUND DATA H Sound power (COOLING MODE) dB(A) HL HA HE Sound power dB(A) H/HA HL/HE 93,5 88,5 93,5 88,5 61,5 56,5 93,5 88,5 93,5 88,5 61,5 56,5 94,5 89,5 94,5 89,5 62,5 57,5 96 91 96 91 63,5 58,5 94 89 94 89 62 57 95 90 95 90 63 58 96 91 96 91 63,5 58,5 96,5 91,5 96,5 91,5 64 59 25 2 HAH/E HA/HE HA/HE 96,0 101,2 98,1 132,9 6 1 96,0 101,2 132,9 132,9

Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

212

Technical data
NSH U.M VERS. H Cooling capacity kW HL HA HE H Total input power kW HL HA HE H Water flow rate evaporator l/h HL HA HE H Pressure drop evaporator kPa HL HA HE Heating capacity Total input power Water flow condenser Pressure drop condenser EFFICIENCIES H EER W/W HL HA HE COP W/W H/HL HA/HE H ESEER W/W HL HA HE ELECTRICAL DATA Power supply H Total input current (COOLING MODE) Total input current (HEATING MODE) Maximum current (FLA) Starting current (LRA) A HL HA HE A A A H/HL HA/HE H/HL HA/HE H/HL HA/HE 245 259 233 254 246 236 370 370 350 350 283 302 268 293 279 267 390 390 365 365 310 333 295 333 301 292 410 410 436 436 400V 3PH~ 50Hz 330 354 318 349 319 303 443 443 461 461 340 368 335 365 335 318 476 476 521 521 363 389 349 380 360 342 500 500 534 534 378 407 370 403 378 359 516 516 578 578 415 445 400 436 407 391 574 574 612 612 453 484 430 468 436 423 631 631 653 653 2,71 2,55 2,98 2,68 2,98 3,20 3,30 3,26 3,56 3,40 2,58 2,36 2,86 2,57 2,90 3,19 3,12 3,04 3,41 3,25 2,54 2,30 2,87 2,53 2,97 3,18 3,07 2,95 3,44 3,18 2,53 2,28 2,80 2,50 2,99 3,19 3,05 2,92 3,36 3,15 2,61 2,33 2,79 2,45 3,01 3,17 3,17 2,98 3,33 3,11 2,50 2,39 2,91 2,57 3,00 3,19 3,09 2,97 3,37 3,15 2,67 2,40 2,87 2,53 3,03 3,21 3,14 2,98 3,31 3,09 2,64 2,39 2,86 2,53 2,98 3,16 3,10 2,96 3,31 3,08 2,62 2,38 2,85 2,52 2,94 3,12 3,07 2,96 3,30 3,09 kW H/HL HA/HE kW l/h kPa H/HL HA/HE H/HL HA/HE H/HL HA/HE 2202 394 380 413 393 145,33 149,21 138,75 146,55 67940 65532 71380 67940 40 37 53 48 437 452 146,65 141,14 74820 77400 51 67 2352 432 414 454 435 167,28 175,21 158,40 169,26 74476 71380 78260 74992 35 34 37 34 481 504 165,67 157,80 82388 86344 47 49 2502 465 445 498 487 183,56 193,41 173,55 192,42 80324 76712 86000 83936 41 38 38 35 525 543 176,90 170,85 89956 93052 50 47 2652 490 468 523 505 194,00 204,92 186,68 202,53 84452 80668 90300 87204 23 21 40 37 557 565 186,34 176,99 95632 96836 31 49 2802 518 491 546 516 198,12 210,97 195,86 210,63 89268 84624 94256 89096 25 22 43 39 590 587 195,55 185,20 101136 100620 35 53 3002 557 531 590 559 222,47 222,30 202,63 217,40 95976 91504 101824 96320 32 29 34 30 629 631 209,95 197,88 107844 108188 43 41 3202 592 560 619 585 221,83 233,59 215,39 231,20 102168 96664 106640 100792 39 35 27 24 674 666 222,47 207,64 115584 114208 53 33 *3402 649 615 674 635 245,81 257,60 235,86 251,60 111972 106124 116272 109564 35 32 35 31 719 727 241,36 230,21 123324 124700 47 43 *3602 706 670 730 686 269,80 281,63 256,38 272,03 121776 115584 125904 118336 32 30 43 38 764 789 260,16 252,87 131064 135192 40 54

data in accordance with ISO EN 14511:2011 NOMINALCONDITIONS: Cooling mode entering water temperature 12 C leaving water temperature 7 C external air temperature 35 C t = 5 K. Heating mode entering water temperature 40 C leaving water temperature 45 C external air temperature 7 C t = 5 K.

* EUROVENT Not certified model

211

Technical Data
NSH COMPRESSOR N compressors/circuits FANS H Air flow rate m/h HL HA HE H Total input power kW HL HA HE H Total input current A HL HA HE H Quantity n HL HA HE SHELL & TUBE HEAT EXCHANGER Water contents dm3 H/HL Water connections Quantity n H/HL H/HL 1 159,8 1 1 159,8 1 1 149,9 1 1 220,7 1 214000 149800 196000 137200 17,5 12 17,5 12 37,0 37,0 37,0 37,0 10 10 10 10 138,2 214000 149800 196000 137200 17,5 12 17,5 12 37,0 37,0 37,0 37,0 10 10 10 10 132,9 214000 149800 196000 137200 17,5 12 17,5 12 37,0 37,0 37,0 37,0 10 10 10 10 159,8 207000 144900 191500 134050 17,5 12 17,5 12 37,0 37,0 37,0 37,0 10 10 10 10 159,8 U.M VERS 2202 2352 2502 2652 2802 BI-SCREW 2/2 STANDARD 200000 140000 187000 130900 17,5 12 17,5 12 37,0 37,0 37,0 37,0 10 10 10 10 159,8 6 1 220,7 6 1 25 2 96,5 91,5 96,5 91,5 64 59 2 96,5 91,5 96,5 91,5 64 59 2 97 92 97 92 64,5 59,5 2 97 92 97 92 64,5 59,5 2 97 92 97 92 64,5 59,5 4 97 92 97 92 64 59 4 97,5 92,5 97,5 92,5 65 60 4 98,5 93,5 98,5 93,5 65,5 60,5 4 99 94 99 94 66 61 2 2 2 2 2 199,3 2 196,2 2 231,0 2 265,8 248400 173880 229800 196140 21 14,4 21,0 14,4 44,4 44,4 44,4 44,4 12 12 12 12 199,2 240000 168000 224400 157080 21 14,4 21,0 14,4 44,4 44,4 44,4 44,4 12 12 12 12 196,0 291200 203840 268200 187740 24,5 16,8 24,5 16,8 51,8 51,8 51,8 51,8 14 14 14 14 236,2 342400 239680 312000 218400 28 19,2 28,0 19,2 59,2 59,2 59,2 59,2 16 16 16 16 276,4 3002 3202 3402 3602

SHELL & TUBE HEAT EXCHANGER Water contents dm3 HA/HE Water connections Quantity EXPANSION VESSEL Capacity Quantity SOUND DATA H Sound power (coolign mode) dB(A) HL HA HE Sound pressure dB(A) dB(A) H/HA HL/HE dm3 n All All n HA/HE HA/HE

Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

214

Dimensions (mm)

C B

DIMENSIONS Height (A) Width (B) Lenght (C) Weight empty Weight operating Weight empty Weight operating

U.M. mm mm mm Kg Kg Kg Kg

Vers. All All All HH/L HH/L HA/HE HA/HE

1251 2450 2200 3780 3150 3255 3245 3340

1401 2450 2200 3780 3165 3265 3280 3380

1601 2450 2200 3780 3340 3440 3435 3535

1801 2450 2200 4770 4005 4145 4115 4250

1402 2450 2200 3780 3475 3580 3570 3665

1602 2450 2200 3780 3800 3900 3835 3935

1802 2450 2200 4770 3930 4075 4005 4140

2002 2450 2200 5750 4290 4435 4385 4520

DIMENSIONS Height (A) Width (B) Lenght (C) Weight empty Weight operating Weight empty Weight operating

U.M. mm mm mm Kg Kg Kg Kg

Vers. All All All H/HL H/HL HA/HE HA/HE

2202 2450 2200 5750 4355 4495 4570 4730

2352 2450 2200 5750 4735 4870 4940 5100

2502 2450 2200 5750 5090 5250 5265 5415

2652 2450 2200 5750 5210 5370 5470 5690

2802 2450 2200 5750 5330 5490 5610 5830

3002 2450 2200 7160 6330 6530 6540 6740

3202 2450 2200 7160 6555 6750 6745 6940

3402 2450 2200 8150 7220 7455 7425 7655

3602 2450 2200 9140 7885 8160 8105 8370 Cod.: SNSHUY.02 /1302

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

215

NS

1251/7203 free-cooling

Air cooled chillers with axial fans and screw compressors Cooling capacity from 272 to 1554 kW Free-cooling capacity from 280 to 1510 kW

R134a

OPERATES TO 46C AMBIENT AVAILABLE WITH PUMP ASSEMBLY


Characteristics
R134a refrigerant High efficiency even at part load Screw compressors with modulating capacity control from 40 to 100%. (25 to 100% with electronic expansion valve option) and acoustical enclosure as standard Shell and tube heat exchanger optimised for refrigerant R134a Electronic expansion valve as standard in sizes 5002 to 5702 Three-way valve installed on the hydraulic circuit to modulate flow to the Free-cooling coil Modulating capacity control microprocessor system with multilingual display panel Extremely robust construction with anti-corrosion polyester paint Available in 32 sizes Available versions: High Efficiency [A], Low noise High Efficiency [E] Partial heat recovery (option) desuperheater) Pump assembly option (single pump or run and standby pumps with two 25 litre expansion vessels) Inverter fans with high static pressure option Condenser coil with aluminium, coated aluminium, copper or tinned copper fins Wide operating limits - Maximum external air temperature: 42C for size 1601 and from 3002 to 3402 44C for sizes 5002 to 5702 46C for all other sizes - Ability to exceed operating limits with a reduction of capacity using an intelligent algorithm that avoids a fault trip-out Low sound level Low noise axial fans with aerodynamic profile blades Acoustical compressor enclosure as standard For the low-noise versions: - Hot gas discharge muffler - Optional acoustic kit AK, including enhanced soundproofing enclosures and additional insulation DCPX as standard: fan speed control by means of phase-cut controller

Accessories
AER 485P1: RS-485 interface for supervision at time of order and is available factory fitted AERWEB300-18G: Web server to monitor and systems with MODBUS protocol. only. For compatibility of the RIF device refer remote control max. 18 units in RS485 net AVX: Spring anti-vibration mounts. For comto the technical manual. work with integrated GPRS modem; patibility of the AVX mounts refer to the tech- AERWEB300: Accessory AERWEB allows AK: ACOUSTIC KIT (only for Versions E). nical manual. remote control of a chiller through a com- This accessory allows further sound reduc KRSDES: (available for desuperheater "D" mon PC and an ethernet connection over a tion. Must be requested at time of order and option). E vaporator and desuperheater common browser; 4 versions available: is available factory fitted only. exchangers trace heating. Factory fitted only AERWEB300-6: Web server to monitor and MULTICHILLER: Control system for multiple GP: Protective grille. Condenser coil external remote control max. 6 units in RS485 netparallel installed constant flow chillers proprotection against accidental or hail damage. work; viding individual chiller on/off and control Factory fitted. AERWEB300-18: Web server to monitor and capability. PRV3: Remote control of the chiller operatremote control max. 18 units in RS485 neting functions. work; RIFNS :Power factor correction. Connected in AERWEB300-6G: Web server to monitor and parallel to the motor allowing about 10% remote control max. 6 units in RS485 netreduction of input current. Must be requested work with integrated GPRS modem;

216

Compatibility accessories
Mod. NS AER485P1 MULTICHILLER (1)(3)AK-ACUSTIC KIT PRV3 AERWEB300 Mod. NS AER485P1 MULTICHILLER (1)(3)AK-ACUSTIC KIT PRV3 AERWEB300 1251 (x1) 3202 (x2) 1401 (x1) 3402 (x2) 1601 (x1) 3602 (x2) 1801 (x1) 3902 (x2) 2101 (x1) 4202 (x2) 2401 (x1) 4502 (x2) 1402 (x2) 4802 (x2) 1602 (x2) 5002 (x2) 1802 (x2) 5202 (x2) 2002 (x2) 5402 (x2) 2202 (x2) 5702 (x2) 2352 (x2) 6003 (x3) 2502 (x2) 6303 (x3) 2652 (x2) 6603 (x3) 2802 (x2) 6903 (x3) 3002 (x2) 7203 (x3)

Mod. NS A/E 1251 1401 1601 1801 2101 2401 1402 1602 1802 2002 2202 2352 2502 2652 2802 3002 (1)GP 300M (1)GP 400M (1)GP 500M (1)GP 300B (1)GP 400B (1)GP 500B (1)GP 300M+300M KRS10DES KRS10DES KRS11DES KRS11DES KRS11DES KRS19DES KRS19DES KRS19DES KRS18DES KRS18DES KRS19DES KRS19DES KRS19DES KRS19DES KRS19DES KRS13DES (1)(4)KRSDES Mod. NS A/E 3202 3402 3602 3902 4202 4502 4802 5002 5202 5402 5702 6003 6303 6603 6903 7203 (1)GP 300M+300M (1)GP 300M+400M (1)GP 400M+400M (1)GP 400M+500M (1)GP 500M+500M (1)GP 400M+400M+500M (1)GP 400M+500M+500M (1)GP 500M+500M+500M KRS14DES KRS13DES KRS12DES KRS13DES KRS13DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS15DES KRS16DES KRS16DES KRS17DES KRS17DES (1)(4)KRSDES Mod. NS A/E 1251 1401 1601 1801 2101 2401 1402 1602 1802 2002 2202 2352 2502 2652 2802 3002 AVX 501 501 501 506 512 512 501 501 505 511 511 511 511 511 511 509 1251F 1401F 1601F 1801 2101 2401 1402 1602 1802 2002 2202 2352 2502 2602 2802 3002F (1)(2)RIFNS* Mod. NS A/E 3202 3402 3602 3902 4202 4502 4802 5002 5202 5402 5702 6003 6303 6603 6903 7203 AVX 507 513 516 518 518 521 521 560 560 560 560 525 527 527 530 530 3202F 3402F 3602 3902 4202 4502 4802 5002 5202 5402 5702 6003 6303 6603 6903 7203 (1)(2)RIFNS* *example: RIFNS1251F (3) Accessory only available for low noise versions Notes: (1) Accessory only factory fitted. Number in brackets, i.e. (x1) indicates quantity. (4) Accessory KRSDES includes evaporator and desuperheater heat exchangers trace heating (2) Accessory only available with 400V-3-50Hz power supply

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.
Field key: 12 | Code Code: NS Size: 1251, 1401, 1601, 1801, 2101, 2401, 1402, 1602, 1802, 2002, 2202 2352, 2502, 2652, 2802,3002, 3202,3402, 3602, 3902,4202,4502, 4802, 5002, 5202, 5402, 5703, 6003, 6303, 6603, 6903, 7203 Expansion device: - Thermostatic expansion valve, minimum leaving water temperature +4C Y - Thermostatic expansion valve , leaving liquid temperature +4C to -6C X - Electronic expansion valve, minimum leaving water temperature +4C (for lower temperatures please contact the factory) Model: F - Free-cooling Heat recovery: - Without heat recovery D -With desuperheater Version: A - High efficiency E - High efficiency low noise version Coil: S - Aluminium - Tinned copper R - Copper V - Anti-corrosion coated aluminium 3 4 5 6 7 | | | Expansion device | Size 8 9 | | | Heat recovery | Model 10 11 | | | Condenser coil | Version Fan: J - Standard - Inverters (not compatible with Power supply fields 5 and 9) - 400V 3~ 50Hz with fuses M - High static pressure (not compatible with Power supply fields 2, 4, 5 and 9) Power supply: 2 - 230V 3~ 50Hz with fuses * 4 - 230V 3~ 50Hz with circuit breakers * 5 - 500V 3~ 50Hz with fuses ** 8 - 400V 3~ 50Hz with circuit breakers 9 - 500V 3~ 50Hz with circuit breakers ** Pump assembly: 00 - Without pump assembly PA - Pump assembly (Pump A) PB - Pump assembly (Pump A and standby pump) PC - Pump assembly (Pump C) PD - Pump assembly (Pump C and standby pump) PE - Pump assembly (Pump E) PF - Pump assembly (Pump E and standby pump) PG - Pump assembly (Pump G) PH - Pump assembly (Pump G and standby pump) PJ - Pump assembly (Pump J) PK - Pump assembly (Pump J and standby pump) PN - Pump assembly (Pump N) *** PO - Pump assembly (Pump N and standby pump)*** 12 13 14 15 | | | | Power supply | | | Fan Pump assembly

PP - Pump assembly (Pump P) *** PQ - Pump assembly (Pump P and standby pump)***

Limitations of option D with Desuperheater not available in sizes 2002-2802 available in sizes 1251 to 1601, 1402, 1602, 1801, 1802, from 3002 to 4202, and from 6003 to 6603 without evaporator pump assembly

* not available in sizes 1251 to 2401, and 2352 to 7203 ** not available in sizes 1801 to 2401, and 3402 to 7203 ***not available in sizes 1251 to 1801, 1402 to 2002, 3002 to 4202, and 6003 to 6603

217

Technical Data
Mod. NS Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total input current Water flow rate Compressors *Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (Chiller) Air flow rate (Chiller) Sound pressure (Freecooling) Air flow rate (Freecooling) Fans Evaporators (1) Mod. NS Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total input current Water flow rate Compressors *Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (Chiller) Air flow rate (Chiller) Sound pressure (Freecooling) Air flow rate (Freecooling) Fans Evaporators (1) Mod. NS Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total input current A A kW kW A l/h n dB(A) dB(A) dBA dBA m3/h m3/h n n U.M. kW kW W/W A kW kW W/W A l/h n dB(A) dB(A) dBA dBA m3/h m3/h n n U.M. kW kW A kW kW U.M. kW kW Vers. FA FE FA FE FA FE FA FE FA FE All FA FE All FA FE All % FA FE FA FA FE FA FA FE FA FA/FE FA/FE Vers. FA FE FA FE FA FE FA FE FA FE All FA FE All FA FE All % FA FE FA FA FE FA FA FE FA All All Vers. FA FE FA FE FA FE FA FE FA FE All FA FE All 1251 272 243 91 93 2.99 2.61 160 164 280 268 12 23.3 22.3 24 46780 41800 1 40-100 94 86 94 62 54 62 102000 70000 102000 6 1 2002 429 389 153 156 2.80 2.49 261 266 452 420 20 22.6 21.0 40 73790 66910 2 40-100 98 90 98 66 58 66 170000 124500 170000 10 1 3602 817 744 288 298 2.84 2.50 476 493 807 782 32 25.2 24.4 64 1401 304 282 104 105 2.92 2.69 180 182 291 283 12 24.3 23.6 24 52290 48500 1 40-100 95 87 95 63 55 63 102000 78000 102000 6 1 2202 480 439 168 167 2.86 2.63 288 286 491 476 20 24.6 23.8 40 82560 75510 2 40-100 98 90 98 66 58 66 170000 120000 170000 10 1 3902 873 787 300 311 2.91 2.53 505 524 889 585 36 24.7 16.3 72 1601 338 322 115 117 2.94 2.75 196 199 301 297 12 25.1 24.8 24 58140 55380 1 40-100 97 89 97 65 57 65 102000 87000 102000 6 1 2352 501 457 177 179 2.83 2.55 305 308 498 483 20 24.9 24.2 40 86170 78600 2 40-100 98 90 98 66 58 66 170000 123000 170000 10 1 4202 926 843 321 333 2.88 2.53 537 557 907 881 36 25.2 24.5 72 1801 408 372 144 148 2.83 2.51 238 245 403 391 16 25.2 24.4 32 70180 63980 1 40-100 97 89 97 65 57 65 136000 100000 136000 8 1 2502 522 475 186 191 2.81 2.49 322 331 505 489 20 25.3 24.5 40 89780 81700 2 40-100 98 90 98 66 58 66 170000 130000 170000 10 1 4502 983 887 334 346 2.94 2.56 566 586 989 956 40 24.7 23.9 80 2101 465 415 157 161 2.96 2.58 267 274 486 466 20 24.3 23.3 40 79980 71380 1 40-100 98 90 98 66 58 66 170000 112000 170000 10 1 2652 553 514 200 203 2.77 2.53 344 349 514 502 20 25.7 25.1 40 95120 88410 2 40-100 99 91 99 67 59 67 170000 130000 170000 10 1 4802 1036 943 354 369 2.93 2.56 598 623 1007 979 40 25.2 24.5 80 2401 518 471 177 183 2.93 2.57 299 309 503 490 20 25.2 24.5 40 89100 81010 1 40-100 98 90 98 66 58 66 170000 127000 170000 10 1 2802 584 554 215 214 2.72 2.59 366 364 522 514 20 26.1 25.7 40 100450 95290 2 40-100 99 91 99 67 59 67 170000 140000 170000 10 1 5002 1084 1017 374 381 2.90 2.67 629 641 993 976 40 24.8 24.4 80 1402 285 257 103 105 2.77 2.45 179 182 285 249 12 23.8 20.8 24 49020 44200 2 40-100 96 88 96 64 56 64 102000 74000 102000 6 1 3002 642 604 219 222 2.93 2.72 376 381 592 580 24 24.7 24.2 48 110430 103890 2 40-100 99 91 99 67 59 67 204000 165000 204000 12 2 5202 1154 1066 403 413 2.86 2.58 672 689 1009 988 40 25.2 24.7 80 1602 324 295 119 121 2.72 2.44 205 208 297 288 12 24.8 24.0 24 55730 50740 2 40-100 97 89 97 65 57 65 102000 80000 102000 6 1 3202 675 645 230 233 2.93 2.77 391 396 602 594 24 25.1 24.8 48 116100 110940 2 40-100 100 92 100 68 60 68 204000 174000 204000 12 2 5402 1225 1116 432 445 2.84 2.51 714 735 1025 1001 40 25.6 25.0 80 1802 377 340 133 136 2.83 2.50 225 230 393 379 16 24.6 23.7 32 64840 58480 2 40-100 97 89 97 65 57 65 136000 96000 136000 8 1 3402 746 694 259 265 2.88 2.62 434 444 705 688 28 25.2 24.6 56 128310 119370 2 40-100 100 92 100 68 60 68 238000 187000 238000 14 2 5702 1282 1159 444 457 2.89 2.54 743 765 1035 1010 40 25.9 25.3 80

SOUND POWER Sound power measured with intensity method in accordance with UNI EN ISO 9614-1, as required for Eurovent certication.

SOUND PRESSURE Sound pressure measured in free eld over a reective plane at a distance of 10m and directivity factor of 2. In accordance with ISO 3744 standard. Power supply 400V.

*40-100 - Modulating capacity 25-100 - Electronic expansion valve

218

Technical Data
Mod. NS Water flow rate Compressors *Capacity control Sound power (Chiller) Sound power (Freecooling) Sound pressure (Chiller) Air flow rate (Chiller) Sound pressure (Freecooling) Air flow rate (Freecooling) Fans Evaporators (1) Mod. NS Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total input current Water flow rate Compressors *Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (Chiller) Air flow rate (Chiller) Sound pressure (Freecooling) Air flow rate (Freecooling) Fans Evaporators (1) U.M. l/h n dB(A) dB(A) dBA dBA m3/h m3/h n n U.M. kW kW W/W A kW kW W/W A l/h n dB(A) dB(A) dBA dBA m3/h m3/h n n Vers. FA FE All % FA FE FA FA FE All FA FE FA FA/FE FA/FE Vers. FA FE FA FE FA FE FA FE FA FE All FA FE All FA FE All % FA FE FA FA FE FA FA FE FA FA/FE FA/FE 3602 140530 127970 2 40-100 100 92 100 68 60 68 272000 200000 272000 16 2 6003 1335 1216 465 479 2.87 2.54 775 798 1310 1272 52 25.2 24.5 104 229620 209150 3 40-100 102 94 102 70 62 70 442000 327000 442000 26 3 3902 150160 135370 2 40-100 101 93 101 69 61 69 306000 212000 306000 18 2 4202 159270 145000 2 40-100 101 93 101 69 61 69 306000 227000 306000 18 2 4502 169080 152570 2 40-100 101 93 101 69 61 69 340000 239000 340000 20 2 7203 1554 1414 532 549 2.92 2.58 897 926 1510 1469 60 25.2 24.5 120 267290 243210 3 40-100 103 95 103 71 63 71 510000 381000 510000 30 3 4802 178190 162200 2 40-100 101 93 101 69 61 69 340000 254000 340000 20 2 5002 186450 174930 2 25-100 102 94 102 70 62 70 340000 254000 340000 20 2 5202 198490 183350 2 25-100 102 94 102 71 63 71 340000 254000 340000 20 2 5402 210700 191950 2 25-100 102 94 102 71 63 71 340000 254000 340000 20 2 5702 220510 199350 2 25-100 102 94 102 71 63 71 340000 254000 340000 20 2

6303 1391 1259 478 492 2.91 2.56 804 828 1393 1347 56 24.9 24.1 112 239250 216550 3 40-100 102 94 102 70 62 70 476000 339000 476000 28 3

6603 1444 1315 498 514 2.90 2.56 836 863 1410 1371 56 25.2 24.5 112 248370 226180 3 40-100 103 95 103 71 63 71 476000 354000 476000 28 3

6903 1501 1358 511 527 2.94 2.58 865 892 1493 1446 60 24.9 24.1 120 258170 233580 3 40-100 103 95 103 71 63 71 510000 366000 510000 30 3

(1) = Tubular

band Power supply voltage = 400V 3~ 50 Hz. Performance values refer to the following conditions: Cooling: - water inlet temperature - water outlet temperature - outside air temp. - Dt = 5 C. Free-cooling - water inlet temperature - outside air temp. - Glycol

12 C; 7 C; 35 C;

15C 2C 0%

SOUND POWER Sound power measured with intensity method in accordance with UNI EN ISO 9614-1, as required for Eurovent certication. SOUND PRESSURE Sound pressure measured in free eld over a reective plane at a distance of 10m and directivity factor of 2. In accordance with ISO 3744 standard. Power supply 400V.

*40-100 - Partload continuous 25-100 - Electronic expansion valve

Dimensions (mm)
Mod. NS(F) Height Width Length Weight Mod. NS(F) Height Width Length Weight Mod. NS(F) Height Width Length Weight Mod. NS(F) Height Width Length Weight Version (A) (B) (C) kg (A) (B) (C) kg (A) (B) (C) kg (A) (B) (C) kg A/E A/E Version A/E A/E Version A/E A/E Version A/E A/E 1251 2450 2200 3780 3760 1602 2450 2200 3780 4030 2802 2450 2200 5750 6350 4502 2450 2200 11100 11104 1401 2450 2200 3780 3770 1802 2450 2200 4770 4730 3002 2450 2200 7160 7210 4802 2450 2200 11100 11320 1601 2450 2200 3780 3840 2002 2450 2200 5750 5470 3202 2450 2200 7160 7310 5002 2450 2200 11100 12300 1801 2450 2200 4770 5000 2202 2450 2200 5750 5790 3402 2450 2200 8150 8410 5202 2450 2200 11100 12600 2101 2450 2200 5750 5950 2352 2450 2200 5750 6340 3602 2450 2200 9140 9180 5402 2450 2200 11100 12700 2401 2450 2200 5750 5980 2502 2450 2200 5750 6330 3902 2450 2200 10120 10580 5702 2450 2200 11100 12800 1402 2450 2200 3780 4010 2652 2450 2200 5750 6340 4202 2450 2200 10120 11580 6003 2450 2200 14490 15160 6303 2450 2200 15470 16560 6603 2450 2200 15470 16840

C B

For transport reasons NS FREECOOLING sizes 6003 to 7203 are shipped separated; one module consisting of two compressors and standard electrical panel (placed in front of the unit) and one module with one compressor and the electrical panel placed on the
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

compressor side beneath the condenser coil. On the site it is only necessary to connect the two sections electrically. For more information refer to the technical and/or installation manual.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

219

Cod.: SNSFCUY.00 / 1211

6903 2450 2200 16450 17084

7203 2450 2200 16450 17300

NEW

NS

Air cooled chillers with axial fans and screw compressors Cooling capacity from 251 to 1542 kW Free-cooling capacity from 251 to 1542 kW

1251/7203
free-cooling HWT

R134a

DATA CENTERS &


PROCESS COOLING Applications

Designed for

OPERATES TO 46 C AMBIENT WATER PRODUCTION UP TO 30 C AVAILABLE WITH PUMP ASSEMBLY


Characteristics
R134a refrigerant High efficiency even at part load Screw compressors with modulating capacity control from 25 to 100% with electronic expansion valve, and acoustical enclosure as standard Shell and tube heat exchanger optimised for refrigerant R134a Electronic expansion valve standard for all sizes Three-way valve installed on the hydraulic circuit to modulate flow to the Free-cooling coil Modulating capacity control microprocessor system with multilingual display panel Extremely robust construction with anti-corrosion polyester paint Available in 32 sizes Available versions: High Efficiency [A], Low noise High Efficiency [E] Partial heat recovery (option) desuperheater) Pump assembly option (single pump or run and standby pumps with two 25 litre expansion vessels) Inverter fans with high static pressure option Condenser coil with aluminium, coated aluminium, copper or tinned copper fins Wide operating limits - Maximum external air temperature: 44C for size 2802 and from 5002 to 5702 46C for all other sizes - Ability to exceed operating limits with a reduction of capacity using an intelligent algorithm that avoids a fault trip-out Low sound level Low noise axial fans with aerodynamic profile blades Acoustical compressor enclosure as standard For the low-noise versions: - Hot gas discharge muffler - Optional acoustic kit AK, including enhanced soundproofing enclosures and additional insulation DCPX as standard: fan speed control by means of phase-cut controller

Accessori
AER 485P1: RS-485 interface for supervision only. For compatibility of the RIF device refer to the technical manual. AERWEB300-18G: Web server to monitor and systems with MODBUS protocol. remote control max. 18 units in RS485 net AVX: Spring anti-vibration mounts. For com- AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC work with integrated GPRS modem; patibility of the AVX mounts refer to the techand an ethernet connection over a common AK: ACOUSTIC KIT (only for Versions E). nical manual. browser; 4 versions available: This accessory allows further sound reduc GP: Protective grille. Condenser coil external AERWEB300-6: Web server to monitor and tion. Must be requested at time of order and protection against accidental or hail damage. remote control max. 6 units in RS485 netis available factory fitted only. Factory fitted. work; MULTICHILLER: Control system for multiple PRV3: Remote control of the chiller operating AERWEB300-18: Web server to monitor and parallel installed constant flow chillers profunctions. remote control max. 18 units in RS485 netviding individual chiller on/off and control RIFNS : Power factor correction. Connected in work; capability. parallel to the motor allowing about 10% AERWEB300-6G: Web server to monitor and reduction of input current. Must be requested remote control max. 6 units in RS485 netat time of order and is available factory fitted work with integrated GPRS modem;

220

Compatibility Accessories
Mod. NS_W_F AER485P1 MULTICHILLER AK-ACUSTIC KIT (1)(3) PRV3 AERWEB300 Mod. NS_W_F AER485P1 MULTICHILLER AK-ACUSTIC KIT (1)(3) PRV3 AERWEB300 Mod. NS_W_F_A/E GP 300M (1) GP 400M (1) GP 500M (1) GP 300B (1) GP 400B (1) GP 500B (1) GP 300M+300M (1) Mod. NS_W_F_A/E GP 300M+300M (1) GP 300M+400M (1) GP 400M+400M (1) GP 400M+500M (1) GP 500M+500M (1) GP 400M+400M+500M (1) GP 400M+500M+500M (1) GP 500M+500M+500M (1) Mod. NS_W_F_A/E AVX RIFNS (1)(2) Mod. NS_W_F_A/E AVX RIFNS (1)(2) 1251 (x1) 3202 (x2) 1251 1401 (x1) 3402 (x2) 1401 1601 (x1) 3602 (x2) 1601 1801 (x1) 3902 (x2) 1801 3202 3402 1251 3202 1401 3402 1601 3602 1801 3902 2101 4202 2401 4502 1402 4802 1602 5002 1802 5202 2002 5402 2202 5702 2352 6003 2502 6303 2652 6603 2802 6903 3002 7203 3602 3902 4202 4502 4802 5002 5202 5402 5702 6003 6303 6603 6903 7203 2101 (x1) 4202 (x2) 2101 2401 (x1) 4502 (x2) 2401 1402 (x2) 4802 (x2) 1402 1602 (x2) 5002 (x2) 1602 1802 (x2) 5202 (x2) 1802 2002 (x2) 5402 (x2) 2002 2202 (x2) 5702 (x2) 2202 2352 (x2) 6003 (x3) 2352 2502 (x2) 6303 (x3) 2502 2652 (x2) 6603 (x3) 2652 2802 (x2) 6903 (x3) 2802 3002 (x2) 7203 (x3) 3002

Notes: (1) Accessory only factory fitted. Number in brackets, i.e. (x1) indicates quantity. (2) Accessory only available with 400V-3-50Hz power supply (3) Accessory only available for low noise versions

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.
Field key:

12 Code

3456 Size

7 Expansion device

8 Model

9 Heat recovery

10 Version

11 Condenser coil

12
Fan

13
Power supply

14 15
Pump assembly

Code:

Power supply:

NS
Size:

- 400V 3~ 50Hz with fuses 8 - 400V 3~ 50Hz with circuit breakers


Pump assembly:

1251, 1401, 1601, 1801, 2101, 2401, 1402, 1602, 1802, 2002, 2202 2352, 2502, 2652, 2802,3002, 3202,3402, 3602, 3902,4202,4502, 4802, 5002, 5202, 5402, 5703, 6003, 6303, 6603, 6903, 7203
Expansion device:

W -Electronic expansion valve, leaving water temperature +5C to +30 C Model: F - Free-cooling
Heat recovery:

- Without heat recovery Version: A - High efficiency E - High efficiency low noise version
Coil:

- Aluminium R - Copper S - Tinned copper V - Anti-corrosion coated aluminium


Fan:

00 - Without pump assembly PA - Pump assembly (Pump A) PB - Pump assembly (Pump A and standby pump) PC - Pump assembly (Pump C) PD - Pump assembly (Pump C and standby pump) PE - Pump assembly (Pump E) PF - Pump assembly (Pump E and standby pump) PG - Pump assembly (Pump G) PH - Pump assembly (Pump G and standby pump) PJ - Pump assembly (Pump J) PK - Pump assembly (Pump J and standby pump) PN - Pump assembly (Pump N) * PO - Pump assembly (Pump N and standby pump)* PP - Pump assembly (Pump P) * PQ - Pump assembly (Pump P and standby pump)*

- Standard M - High static pressure J - Inverters

*not available in sizes 1251 to 1801, 1402 to 2002, 3002 to 4202, and 6003 to 6603

221

Technical Data
Mod. NS_W_F Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total air temperature free-cooling Total input current Water flow rate Compressors Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (chiller) Sound pressure (freecooling) Air flow rate (Chiller) Air flow rate (Freecooling) Fans Evaporators (1) Mod. NS_W_F Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total air temperature free-cooling Total input current Water flow rate Compressors Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (chiller) Sound pressure (freecooling) Air flow rate (Chiller) Air flow rate (Freecooling) Fans Evaporators (1) Mod. NS_W_F Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total air temperature free-cooling Total input current C C A A kW kW C C A l/h n dB(A) dB(A) dB(A) dB(A) m3/h m3/h n n U.M. kW kW W/W A kW kW W/W C C A l/h n dB(A) dB(A) dB(A) dB(A) m3/h m3/h n n U.M. kW kW A kW kW U.M. kW kW Vers. FA FE FA FE FA FE FA FE FA FE All FA FE FA FE All FA FE All % FA FE FA FA FE FA FA FE FA FA/FE FA/FE Vers. FA FE FA FE FA FE FA FE FA FE All FA FE FA FE All FA FE All % FA FE FA FA FE FA FA FE FA All All Vers. FA FE FA FE FA FE FA FE FA FE All FA FE FA FE All 1251 265 251 71 73 3,73 3,44 123 125 265 251 12 22,1 20,9 12,7 12,8 24 45580 43172 1 25-100 94 86 94 62 54 62 102000 70000 102000 6 1 2002 445 419 118 122 3,77 3,43 208 212 445 419 20 22,3 21,0 12,2 12,0 40 76540 72068 2 25-100 98 90 98 66 57 66 170000 124500 170000 10 1 3602 796 734 202 212 3,94 3,46 358 370 796 734 32 24,9 22,9 12,2 12,8 64 1401 306 286 83 86 3,69 3,33 142 147 306 286 12 25,5 23,8 11,3 11,9 24 52632 49192 1 25-100 95 87 95 63 55 63 102000 78000 102000 6 1 2202 472 436 122 126 3,87 3,46 212 217 472 436 20 23,6 21,8 12,5 13,1 40 81184 74992 2 25-100 98 90 98 66 58 66 170000 120000 170000 10 1 3902 857 791 214 223 4,00 3,55 375 386 857 791 36 23,8 22,0 12,5 13,0 72 1601 331 307 88 94 3,76 3,27 157 163 331 307 12 27,6 25,6 10,7 11,6 24 56932 52804 1 25-100 97 89 97 65 57 65 102000 87000 102000 6 1 2352 493 461 133 139 3,71 3,32 229 236 493 461 20 24,7 23,1 12,2 12,6 40 84796 79292 2 25-100 98 90 98 66 58 66 170000 123000 170000 10 1 4202 912 839 230 241 3,97 3,48 413 426 912 839 36 25,3 23,3 12,0 12,6 72 1801 398 367 101 106 3,94 3,46 179 185 398 367 16 24,9 22,9 12,2 12,8 32 68456 63124 1 25-100 97 89 97 65 57 65 136000 100000 136000 8 1 2502 520 483 143 150 3,64 3,22 245 254 520 483 20 26,0 24,2 11,6 12,2 40 89440 83076 2 25-100 98 90 98 66 58 66 170000 130000 170000 10 1 4502 973 896 242 252 4,02 3,56 430 442 973 896 40 24,3 22,4 12,2 12,8 80 2101 459 424 113 117 4,06 3,62 196 201 459 424 20 23,0 21,2 12,7 13,2 40 78948 72928 1 25-100 98 90 98 66 57 66 170000 112000 170000 10 1 2652 550 509 155 164 3,55 3,10 265 277 550 509 20 27,5 25,5 11,1 11,8 40 94600 87548 2 25-100 99 91 99 67 59 67 170000 130000 170000 10 1 4802 1028 944 258 270 3,98 3,50 468 482 1028 944 40 25,7 23,6 11,7 12,5 80 2401 514 472 129 135 3,98 3,50 234 241 514 472 20 25,7 23,6 11,7 12,5 40 88408 81184 1 25-100 98 90 98 66 58 66 170000 127000 170000 10 1 2802 574 543 167 177 3,44 3,07 284 298 574 543 20 28,7 27,2 10,7 11,3 40 98728 93396 2 25-100 99 91 99 67 59 67 170000 140000 170000 10 1 5002 1087 1003 281 296 3,87 3,39 496 514 1087 1003 40 27,2 25,1 10,8 11,7 80 1402 304 285 80 85 3,80 3,35 148 152 304 285 12 25,3 23,8 11,1 10,2 24 52288 49020 2 25-100 96 88 96 64 56 64 102000 74000 102000 6 1 3002 637 593 171 180 3,73 3,29 299 310 637 593 24 26,5 24,7 11,0 11,7 48 109564 101996 2 25-100 99 91 99 66 58 66 204000 165000 204000 12 2 5202 1146 1062 304 322 3,77 3,30 524 546 1146 1062 40 28,7 26,6 10,2 11,0 80 1602 340 314 98 103 3,47 3,05 174 181 340 314 12 28,3 26,2 10,1 10,9 24 58480 54008 2 25-100 97 89 97 65 57 65 102000 80000 102000 6 1 3202 662 614 176 188 3,76 3,27 314 326 662 614 24 27,6 25,6 10,7 11,6 48 113864 105608 2 25-100 100 92 100 67 59 67 204000 174000 204000 12 2 5402 1205 1113 332 354 3,63 3,14 568 596 1205 1113 40 30,1 27,8 9,7 10,5 80 1802 411 382 110 114 3,74 3,35 196 201 411 382 16 25,7 23,9 11,4 11,9 32 70692 65704 2 25-100 97 89 97 65 57 65 136000 96000 136000 8 1 3402 729 674 189 200 3,86 3,37 336 348 729 674 28 26,0 24,1 11,5 12,2 56 125388 115928 2 25-100 100 92 100 67 59 67 238000 187000 238000 14 2 5702 1264 1164 360 386 3,51 3,02 612 646 1264 1164 40 31,6 29,1 9,1 10,0 80

Sound power: Aermec determines the value of sound power on the basis of measurements made in accordance with ISO 9614-2, as required for Eurovent certification.

Sound pressure: Measured in free field over a reflective plane (directivity factor Q = 2), at a distance of 10 metres from the outer surface of the unit, in accordance with ISO 3744.

222

Technical Data
Mod. NS_W_F Water flow rate Compressors Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (chiller) Sound pressure (freecooling) Air flow rate (chiller) Air flow rate (freecooling) Fans Evaporators (1) Mod. NS_W_F Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total input current Total air temperature free-cooling Total input current Water flow rate Compressors Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (chiller) Sound pressure (freecooling) Air flow rate (Chiller) Air flow rate (Freecooling) U.M. l/h n dB(A) dB(A) dBA dBA m3/h m3/h n n U.M. kW kW W/W A kW kW W/W C C A l/h n dB(A) dB(A) dB(A) dB(A) m3/h m3/h n n Vers. FA FE All % FA FE FA FA FE FA FA FE FA FA/FE FA/FE Vers. FA FE FA FE FA FE FA FE FA FE All FA FE FA FE All FA FE All % FA FE FA FA FE FA FA FE FA FA/FE FA/FE 3602 136912 126248 2 25-100 100 92 100 67 59 67 272000 200000 272000 16 2 6003 1310 1206 331 347 3,96 3,48 592 611 1310 1206 52 25,2 23,2 12,0 12,7 104 225320 207432 3 25-100 102 94 102 69 62 69 442000 327000 442000 26 3 3902 147404 136052 2 25-100 101 93 101 68 60 68 306000 212000 306000 18 2 6303 1371 1263 343 358 4,00 3,53 609 627 1371 1263 56 24,5 22,6 12,2 12,8 112 235812 217236 3 25-100 102 94 102 69 62 69 476000 339000 476000 28 3 4202 156864 144308 2 25-100 101 93 101 68 60 68 306000 227000 306000 18 2 6603 1426 1311 359 376 3,97 3,49 647 667 1426 1311 56 25,5 23,4 11,9 12,6 112 245272 225492 3 25-100 103 95 103 70 63 70 476000 354000 476000 28 3 4502 167356 154112 2 25-100 101 93 101 68 60 68 340000 239000 340000 20 2 6903 1487 1368 371 387 4,01 3,53 664 683 1487 1368 60 24,8 22,8 12,0 12,7 120 255764 235296 3 25-100 103 95 103 69 63 69 510000 366000 510000 30 3 4802 176816 162368 2 25-100 101 93 101 68 60 68 340000 254000 340000 20 2 7203 1542 1416 387 405 3,98 3,50 702 723 1542 1416 60 25,7 23,6 11,7 12,5 120 265224 243552 3 25-100 103 95 103 69 63 69 510000 381000 510000 30 3 5002 186964 172516 2 25-100 102 94 102 69 61 69 340000 254000 340000 20 2 5202 197112 182664 2 25-100 102 94 102 69 63 69 340000 254000 340000 20 2 5402 207260 191436 2 25-100 102 94 102 69 63 69 340000 254000 340000 20 2 5702 217408 200208 2 25-100 102 94 102 69 63 69 340000 254000 340000 20 2

(1)

= Shell & tube Power supply = 400V 3~ 50 Hz. Performance values refer to the following conditions: Chiller: - entering water temperature 25 C - leaving water temperature 20 C - external air temperature 35 C - t = 5 C. Free-cooling: - entering water temperature 25C - Glycol 0% Sound power: Aermec determines the value of sound power on the basis of measurements made in accordance with ISO 9614-2, as required for Eurovent certification. Sound pressure: Measured in free field over a reflective plane (directivity factor Q = 2), at a distance of 10 metres from the outer surface of the unit, in accordance with ISO 3744.

Fans Evaporators (1)

Dimensions (mm)
Mod. NS_W_F Height Width Lenght Weight Mod. NS_W_F Height Width Lenght Weight Mod. NS_W_F Height Width Lenght Weight Mod. NS_W_F Height Width Lenght Weight Version (A) (B) (C) kg (A) (B) (C) kg (A) (B) (C) kg (A) (B) (C) kg A/E A/E Version A/E A/E Version A/E A/E Version A/E A/E 1251 2450 2200 3780 3468 1602 2450 2200 3780 4030 2802 2450 2200 5750 5774 4502 2450 2200 11100 10213 1401 2450 2200 3780 3482 1802 2450 2200 4770 4730 3002 2450 2200 7160 6913 4802 2450 2200 11100 10420 1601 2450 2200 3780 3840 2002 2450 2200 5750 5182 3202 2450 2200 7160 7310 5002 2450 2200 11100 11706 1801 2450 2200 4770 4622 2202 2450 2200 5750 5232 3402 2450 2200 8150 8023 5202 2450 2200 11100 12312 2101 2450 2200 5750 5509 2352 2450 2200 5750 5769 3602 2450 2200 9140 8424 5402 2450 2200 11100 12385 2401 2450 2200 5750 5530 2502 2450 2200 5750 5745 3902 2450 2200 10120 9761 5702 2450 2200 11100 12458 1402 2450 2200 3780 3668 2652 2450 2200 5750 5760 4202 2450 2200 10120 10032 6003 2450 2200 14490 13954 6303 2450 2200 15470 15291 6603 2450 2200 15470 15562
A

C B

6903 2450 2200 16450 15743

7203 2450 2200 16450 15950

For transport reasons NS FREECOOLING HWT sizes 6003 to 7203 are shipped separated; one module consisting of two compressors and standard electrical panel (placed in front of the unit) and one module with one compressor and the electrical panel placed on the
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

compressor side beneath the condenser coil. On the site it is only necessary to connect the two sections electrically. For more information refer to the technical and/or installation manual.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

223

Cod.: SNSFCHWTUY.00 / 013

NS

1251/7203 glycolfree

Air cooled chillers with axial fans and screw compressors Cooling capacity from 272 to 1554 kW Free-cooling capacity from 213 to 1149 kW

R134a

OPERATES TO 46 C AMBIENT AVAILABLE WITH PUMP ASSEMBLY

Characteristics
R134a refrigerant High efficiency even at part loads Screw compressors with modulating capacity control from 40 to 100% (25 to 100% with electronic expansion valve option) and acoustical enclosure as standard Shell and tube heat exchanger optimised for refrigerant R134a Electronic expansion valve as standard in sizes 5002 to 5702 An intermediate plate heat exchanger provides two circuits: a glycol circuit, where glycol is added to protect the chiller's coils from freezing, and the chilled water circuit without glycol. The glycol circuit includes as standard: - Intermediate plate heat exchanger - Circulation pump - Expansion vessel - Flow switch - Low pressure switch - Gauge - Safety pressure valve Modulating capacity control microprocessor system with multilingual display panel Extremely robust construction with anti-corrosion polyester paint Available in 32 sizes Available versions: High Efficiency [A], Low noise High Efficiency [E] Partial heat recovery (option) desuperheater) Pump assembly option (single pump or run and standby pumps with two 25 litre expansion vessels) Inverter fans with high static pressure option Condenser coil with aluminium, coated aluminium, copper or tinned copper fins Wide operating limits - Maximum external air temperature: 42C for size 1601 and from 3002 to 3402 44C for sizes 5002 to 5702 46C for all other sizes - Ability to exceed operating limits with a reduction of capacity using an intelligent algorithm that avoids a fault trip-out Low sound level Low noise axial fans with aerodynamic profile blades Acoustical compressor enclosure as standard For the low-noise versions: - Hot gas discharge muffler - Optional acoustic kit AK, including enhanced soundproofing enclosures and additional insulation DCPX as standard: fan speed control by means of phase-cut controller

Accessories
AER 485P1: RS-485 interface for supervision systems with MODBUS protocol. AVX: Spring anti-vibration mounts. For compatibility of the AVX mounts refer to the technical manual. KRS: (obligatory accessory with version ). Evaporator trace heating. Factory fitted only. KRSDES: (obligatory accessory version with desuperheater D). Evaporator and desuperheater exchangers trace heating. Factory fitted only. KDI: 20 mm doubled thickness evaporator insulation. Provides stand-still protection down to -20C. Must be ordered in conjunction with options KRS and KRSDES heaters. GP: Protective grille. Condenser coil external protection against accidental or hail damage. Factory fitted. PRV3: Remote control of the chiller operating functions. RIFNS: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted only. For compatibility of the RIF device refer to the technical manual. AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; AK: ACOUSTIC KIT (only for Versions E). This accessory allows further sound reduction. Must be requested at time of order and is available factory fitted only. MULTICHILLER: Control system for multiple parallel installed constant flow chillers providing individual chiller on/off and control capability.

224

Mod. NS AER485P1 MULTICHILLER (1)(3)AK-ACUSTIC KIT PRV3 AERWEB300 Mod. NS AER485P1 MULTICHILLER (1)(3)AK-ACUSTIC KIT PRV3 AERWEB300 Mod. NS A/E (1)GP 300M (1)GP 400M (1)GP 500M (1)GP 300B (1)GP 400B (1)GP 500B (1)GP 300M+300M (1)KRS (1)(4)KRSDES

1251 (x1) 3202 (x2) 1251

1401 (x1) 3402 (x2) 1401

1601 (x1) 3602 (x2) 1601

1801 (x1) 3902 (x2) 1801

2101 (x1) 4202 (x2) 2101

2401 (x1) 4502 (x2) 2401

1402 (x2) 4802 (x2) 1402

1602 (x2) 5002 (x2) 1602

1802 (x2) 5202 (x2) 1802

2002 (x2) 5402 (x2) 2002

2202 (x2) 5702 (x2) 2202

2352 (x2) 6003 (x3) 2352

2502 (x2) 6303 (x3) 2502

2652 (x2) 6603 (x3) 2652

2802 (x2) 6903 (x3) 2802

3002 (x2) 7203 (x3) 3002

KRS10 KRS10 KRS11 KRS10 KRS11 KRS11 KRS11 KRS11 KRS10 KRS10 KRS11 KRS11 KRS11 KRS11 KRS11 KRS13 KRS10DES KRS10DES KRS11DES KRS11DES KRS11DES KRS19DES KRS19DES KRS19DES KRS18DES KRS18DES KRS19DES KRS19DES KRS19DES KRS19DES KRS19DES KRS13DES

Mod. NS A/E 3202 3402 3602 3902 4202 4502 4802 5002 5202 5402 5702 6003 6303 6603 6903 7203 (1)GP 300M+300M (1)GP 300M+400M (1)GP 400M+400M (1)GP 400M+500M (1)GP 500M+500M (1)GP 400M+400M+500M (1)GP 400M+500M+500M (1)GP500M+500M+500M (1)KRS KRS14 KRS13 KRS12 KRS13 KRS13 KRS14 KRS14 KRS14 KRS14 KRS14 KRS14 KRS15 KRS16 KRS16 KRS17 KRS17 (1)(4)KRSDES KRS14DES KRS13DES KRS12DES KRS13DES KRS13DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS14DES KRS15DES KRS16DES KRS16DES KRS17DES KRS17DES Mod. NS A/E 1251 1401 1601 1801 2101 2401 1402 1602 1802 2002 2202 2352 2502 2652 2802 3002 AVX 501 501 501 506 512 512 501 501 505 511 511 511 511 511 511 509 (1)(2)RIFNS* 1251F 1401F 1601F 1801 2101 2401 1402 1602 1802 2002 2202 2352 2502 2602 2802 3002F Mod. NS A/E 3202 3402 3602 3902 4202 4502 4802 5002 5202 5402 5702 6003 6303 6603 6903 7203 AVX 507 513 516 518 518 521 521 560 560 560 560 525 527 527 530 530 (1)(2)RIFNS* 3202F 3402F 3602 3902 4202 4502 4802 5002 5202 5402 5702 6003 6303 6603 6903 7203 *example RIFNS1251F Mod NS A/E
(5) (5) (5) (5)

Mod NS A/E Mod NS A/E Mod NS A/E

KDI (x n) KDI (x n) KDI (x n) KDI (x n)

1251 KDI01 2002 KDI06 3602 KDI03 x2 6003 KDI03 x2+KDI04

1401 KDI01 2202 KDI08 3902 KDI03+KDI04 6303 KDI03+KDI04 x2

1601 KDI02 2352 KDI08 4202 KDI03+KDI04 6603 KDI03+KDI04 x2

1801 KDI03 2502 KDI08 4502 KDI04 x2 6903 KDI04 x3


(4) (5)

2101 KDI04 2652 KDI08 4802 KDI04 x2 7203 KDI04 x3

2401 KDI04 2802 KDI08 5002 KDI04+KDI05

1402 KDI06 3002 KDI01+KDI02 5202 KDI05 x2

1602 KDI06 3202 KDI02 x2 5402 KDI05 x2

1802 KDI06 3402 KDI02+KDI03 5702 KDI05 x2

Notes: (1) Accessory only factory fitted. Number in brackets, i.e. (x1) indicates quantity. (2) Accessory only available with 400V-3-50Hz power supply (3) Accessory only available for low noise versions

Accessory KRSDES includes evaporator and desuperheater heat exchangers trace heating Accessory KDI must always be combined with the KRS and KRSDES heating elements.

KRS(obligatory accessory version )/KRSDES(obligatory accessory version with desuperheater D)

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.
Field key: 12 | Code Code: NS Size: 1251, 1401, 1601, 1801, 2101, 2401, 1402, 1602, 1802, 2002, 2202 2352, 2502, 2652, 2802,3002, 3202,3402, 3602, 3902,4202,4502, 4802, 5002, 5202, 5402, 5703, 6003, 6303, 6603, 6903, 7203 Expansion device: - Thermostatic expansion valve, minimum leaving water temperature +4C Y - Thermostatic expansion valve , leaving liquid temperature +4C to -6C X - Electronic expansion valve, minimum leaving water temperature +4C (for lower temperatures please contact the factory) Model: 3 4 5 6 7 | | | Expansion device | Size 8 9 | | | Heat recovery | Model 10 11 | | | Condenser coil | Version Fan: J - Standard - Inverters (not compatible with Power supply fields 5 and 9) - 400V 3~ 50Hz with fuses M - High static pressure (not compatible with Power supply fields 2, 4, 5 and 9) Power supply: 2 - 230V 3~ 50Hz with fuses * 4 - 230V 3~ 50Hz with circuit breakers * 5 - 500V 3~ 50Hz with fuses ** 8 - 400V 3~ 50Hz with circuit breakers 9 - 500V 3~ 50Hz with circuit breakers ** Pump assembly: 00 - Without pump assembly PA - Pump assembly (Pump A) PB - Pump assembly (Pump A and standby pump) *** PC - Pump assembly (Pump C) PD - Pump assembly (Pump C and standby pump) *** PE - Pump assembly (Pump E) PF - Pump assembly (Pump E and standby pump) *** PG - Pump assembly (Pump G) - Aluminium - Tinned copper PH - Pump assembly (Pump G and standby pump) *** PJ - Pump assembly (Pump J) PK - Pump assembly (Pump J and standby pump) *** 12 13 14 15 | | | | Power supply | | | Fan Pump assembly

B - Free-cooling Glycol-free
Heat recovery: - Without heat recovery D -With desuperheater Version: A - High efficiency E - High efficiency low noise version Coil: S R - Copper V - Anti-corrosion coated aluminium Limitations of option D with Desuperheater not available in sizes:

- dalla 1251 alla 1601 / 1402,1602 / dalla 2002 alla 3402


available in sizes:

without evaporator pump assembly * not available in sizes 1251 to 2401 and 2352 to 7203 ** not available in sizes 1801 to 2401 and 3402 to 7203 ***not available in sizes 1251 to 1601 and 3002 to 4202

- 1801,1802 / dalla 3602 alla 4202 / dala 6003 alla 6603

Pump assembly option not available in sizes 1402, 1602, 2002

225

Tecnichal data
Mod. NS Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total input current Water flow rate Compressors *Capacity control Sound power (Chiller) Sound power (Freecooling) Sound pressure (Chiller) Air flow rate(Chiller) Sound pressure (Freecooling) Air flow rate (Freecooling) Fans Evaporators (1) Vers. BA kW BE BA kW BE BA BE BA A BE kW BA /BE kW BA /BE BA /BE A BA /BE BA l/h BE n All % BA dB(A) BE BA dB(A) BA dBA BE dBA BA BA m3/h BE m3/h BA n All n All U.M. 1251 272 243 91 93 2.99 2.61 160 164 213 14.0 15.2 28 46780 41800 1 40-100 94 86 94 62 54 62 102000 70000 102000 6 1 1401 304 282 104 105 2.92 2.69 180 182 222 14.0 15.9 28 52290 48500 1 40-100 95 87 95 63 55 63 102000 78000 102000 6 1 1601 338 322 115 117 2.94 2.75 196 199 229 14.0 16.4 28 58140 55380 1 40-100 97 89 97 65 57 65 102000 87000 102000 6 1 1801 408 372 144 148 2.83 2.51 238 245 307 19.8 15.5 40 70180 63980 1 40-100 97 89 97 65 57 65 136000 100000 136000 8 1 2101 465 415 157 161 2.96 2.58 267 274 370 25.3 14.6 51 79980 71380 1 40-100 98 90 98 66 58 66 170000 112000 170000 10 1 2401 518 471 177 183 2.93 2.57 299 309 383 25.5 15.0 51 89100 81010 1 40-100 98 90 98 66 58 66 170000 127000 170000 10 1 1402 285 257 103 105 2.77 2.45 179 182 217 14.0 15.5 28 49020 44200 2 40-100 96 88 96 64 56 64 102000 74000 102000 6 1 1602 324 295 119 121 2.72 2.44 205 208 226 14.0 16.1 28 55730 50740 2 40-100 97 89 97 65 57 65 102000 80000 102000 6 1 1802 377 340 133 136 2.83 2.50 225 230 299 19.8 15.1 40 64840 58480 2 40-100 97 89 97 65 57 65 136000 96000 136000 8 1

Mod. NS Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total Water flow rate Compressors *Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (Freecooling) Air flow rate Air flow rate (Freecooling) Fans Evaporators (1) Sound pressure (Chiller)

Vers. BA BE BA kW BE BA BE BA A BE kW BA /BE kW BA /BE BA /BE A BA /BE BA l/h BE n All % BA dB(A) BE dB(A) BA BA dBA BE dBA BA BA m3/h BE 3 m /h BA n All n All kW

U.M.

2002 429 389 153 156 2.80 2.49 261 266 344 25.3 13.6 51 73790 66910 2 40-100 98 90 98 66 58 66 170000 124500 170000 10 1

2202 480 439 168 167 2.86 2.63 288 286 374 25.3 14.8 51 82560 75510 2 40-100 98 90 98 66 58 66 170000 120000 170000 10 1

2352 501 457 177 179 2.83 2.55 305 308 379 25.4 14.9 51 86170 78600 2 40-100 98 90 98 66 58 66 170000 123000 170000 10 1

2502 522 475 186 191 2.81 2.49 322 331 385 25.5 15.1 51 89780 81700 2 40-100 98 90 98 66 58 66 170000 130000 170000 10 1

2652 553 514 200 203 2.77 2.53 344 349 391 27.1 14.4 54 95120 88410 2 40-100 99 91 99 67 59 67 170000 130000 170000 10 1

2802 584 554 215 214 2.72 2.59 366 364 397 27.2 14.6 54 100450 95290 2 40-100 99 91 99 67 59 67 170000 140000 170000 10 1

3002 642 604 219 222 2.93 2.72 376 381 451 28.0 16.1 56 110430 103890 2 40-100 99 91 99 67 59 67 204000 165000 204000 12 2

3202 675 645 230 233 2.93 2.77 391 396 458 28.0 16.4 56 116100 110940 2 40-100 100 92 100 68 60 68 204000 174000 204000 12 2

3402 746 694 259 265 2.88 2.62 434 444 536 33.8 15.9 68 128310 119370 2 40-100 100 92 100 68 60 68 238000 187000 238000 14 2

Mod. NS Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total input current

U.M. kW kW

A kW kW A

Vers. BA BE BA BE BA BE BA BE BA /BE BA /BE BA /BE BA /BE

3602 817 744 288 298 2.84 2.50 476 493 614 39.6 15.5 79

3902 873 787 300 311 2.91 2.53 505 524 677 45.1 15.0 90

4202 926 843 321 333 2.88 2.53 537 557 690 45.3 15.2 91

4502 983 887 334 346 2.94 2.56 566 586 753 50.8 14.8 102

4802 1036 943 354 369 2.93 2.56 598 623 766 51.0 15.0 102

5002 1084 1017 374 381 2.90 2.67 629 641 756 51.0 14.8 102

5202 1154 1066 403 413 2.86 2.58 672 689 768 51.0 15.1 102

5402 1225 1116 432 445 2.84 2.51 714 735 780 51.0 15.3 102

5702 1282 1159 444 457 2.89 2.54 743 765 788 51.0 15.5 102

SOUND POWER Sound power measured with intensity method in accordance with UNI EN ISO 9614-1, as required for Eurovent certication.

SOUND PRESSURE Sound pressure measured in free eld over a reective plane at a distance of 10m and directivity factor of 2. In accordance with ISO 3744 standard. Power supply 400V.

*40-100 - Modulating capacity 25-100 - Electronic expansion valve

226

Tecnichal data
Mod. NS Water flow rate Compressors *Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (Chiller) Sound pressure (Freecooling) dBA Air flow rate (Chiller) Air flow rate (Freecooling) Fans Evaporators(1) U.M. l/h n dB(A) dB(A) dBA dBA m3/h m3/h n n Vers. BA BE All % BA BE BA BA BE BA BA BE BA All All 3602 140530 127970 2 40-100 100 92 100 68 60 68 272000 200000 272000 16 2 3902 150160 135370 2 40-100 101 93 101 69 61 69 306000 212000 306000 18 2 4202 159270 145000 2 40 - 100 101 93 101 69 61 69 306000 227000 306000 18 2 4502 169080 152570 2 40-100 101 93 101 69 61 69 340000 239000 340000 20 2 4802 178190 162200 2 40-100 101 93 101 69 61 69 340000 254000 340000 20 2 5002 186450 174930 2 25-100 102 94 102 70 62 70 340000 254000 340000 20 2 5202 198490 183350 2 25-100 102 94 102 71 63 71 340000 254000 340000 20 2 5402 210700 191950 2 25-100 102 94 102 71 63 71 340000 254000 340000 20 2 5702 220510 199350 2 25-100 102 94 102 71 63 71 340000 254000 340000 20 2

Mod. NS Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total input current Water flow rate Compressors *Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure(Chiller)

U.M. kW kW W/W A kW kW A l/h n dB(A) dB(A) dBA dBA m3/h m3/h n n

Vers. BA BE BA BE BA BE BA BE BA /BE BA /BE BA /BE BA /BE BA BE All % BA BE BA BA BE BA BA BE BA All All

6003 1335 1216 465 479 2.87 2.54 775 798 984 65.1 15.1 130 229620 209150 3 40-100 102 94 102 70 62 70 442000 327000 442000 26 3

6303 1391 1259 478 492 2.91 2.56 804 828 1060 70.6 15.0 141 239250 216550 3 40-100 102 94 102 70 62 70 476000 339000 476000 28 3

6603 1444 1315 498 514 2.90 2.56 836 863 1073 70.8 15.2 142 248370 226180 3 40-100 103 95 103 71 63 71 476000 354000 476000 28 3

6903 1501 1358 511 527 2.94 2.58 865 892 1136 76.3 14.9 153 258170 233580 3 40-100 103 95 103 71 63 71 510000 366000 510000 30 3

7203 1554 1414 532 549 2.92 2.58 897 926 1149 76.5 15.0 153 267290 243210 3 40-100 103 95 103 71 63 71 510000 381000 510000 30 3

(1) = Shell & tube Power supply = 400V 3~ 50 Hz. Performance values refer to the following conditions: Cooling: - entering water temperature 12 C - leaving water temperature 7 C - external air temperature 35 C - t = 5 K. Free-cooling glycol free - entering water temperature 15C - external air temperature 2C - primary circuit glycol 30% - secondary system circuit glycol 0% *40-100 - Modulating capacity 25-100 - Electronic expansion valve
SOUND POWER Sound power measured with intensity method in accordance with UNI EN ISO 9614-1, as required for Eurovent certication. SOUND PRESSURE Sound pressure measured in free eld over a reective plane at a distance of 10m and directivity factor of 2. In accordance with ISO 3744 standard. Power supply 400V.

Sound pressure (Freecooling) Air flow rate (Chiller) Air flow rate (Freecooling) Fans Evaporators (1)

Dimensions (mm)
Mod. NS "B" Height Width Lenght Weight Mod. NS "B" Height Width Lenght Weight Mod. NS "B" Height Width Lenght Weight (A) (B) (C) kg (A) (B) (C) kg (A) (B) (C) kg 1251 2450 2200 3780 3888 1602 2450 2200 3780 4158 2802 2450 2200 5750 6565 1401 2450 2200 3780 3898 1802 2450 2200 4770 4887 3002 2450 2200 7160 7466 1601 2450 2200 3780 3968 2002 2450 2200 5750 5648 3202 2450 2200 7160 7566 1801 2450 2200 4770 5157 2202 2450 2200 5750 5989 3402 2450 2200 8150 8695 2101 2450 2200 5750 6149 2352 2450 2200 5750 6539 3602 2450 2200 9140 9494 2401 2450 2200 5750 6179 2502 2450 2200 5750 6529 3902 2450 2200 10120 10936 1402 2450 2200 3780 4138 2652 2450 2200 5750 6555 4202 2450 2200 10120 11216

A/E A/E

A/E A/E

A/E A/E

C B

For transport reasons NS GLYCOL FREE sizes 6003 to 7203 are shipped separated; one module consisting of two compressors and standard electrical panel (placed in front of the unit) and one module with one compressor and the

electrical panel placed on the compressor side beneath the condenser coil. On the site it is only necessary to connect the two sections electrically. For more information refer to the technical and/or installation manual.

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Fax 044293730 www.aermec.com

227

Cod.: SNSGFUY.00 / 1201

Mod. NS "B" Height Width Lenght Weight

(A) (B) (C) kg

A/E A/E

4502 2450 2200 11100 11502

4802 2450 2200 11100 11718

5002 2450 2200 11100 12698

5202 2450 2200 11100 12998

5402 2450 2200 11100 13098

5702 2450 2200 11100 13198

6003 2450 2200 14490 15673

6303 2450 2200 15470 17115

6603 2450 2200 15470 17395

6903 2450 2200 16450 17639

7203 2450 2200 16450 17855

NEW

NS

1251/7203
glycolfree HWT

Air cooled chillers with axial fans Cooling capacity from 251 to 1542 kW Cooling capacity in Free-cooling mode from 251 to 1542 kW Screw compressor

R134a
DATA CENTERS &
PROCESS COOLING Applications Designed for

OPERATES TO 46 C AMBIENT WATER PRODUCTION UP TO 30 C AVAILABLE WITH PUMP ASSEMBLY


Characteristics
R134a refrigerant igh efficiency even at part loads Screw compressors with modulating capacity control from 25 to 100% with electronic expansion valve and acoustical enclosure as standard Shell and tube heat exchanger optimised for refrigerant R134a Electronic expansion valve as standard for all sizes An intermediate plate heat exchanger provides two circuits: a glycol circuit, where glycol is added to protect the chiller's coils from freezing, and the chilled water circuit without glycol. The glycol circuit includes as standard: - Intermediate plate heat exchanger - Circulation pump - Expansion vessel - Flow switch - Low pressure switch - Manometer - Safety valve Modulating capacity control microprocessor system with multilingual display panel Extremely robust construction with anti-corrosion polyester paint Available in 32 sizes Available versions: High Efficiency [A], Low noise High Efficiency [E] Pump assembly option (single pump or run and standby pumps with two 25 litre expansion vessels) High static pressure fan (M) and Inverter (J) fans options Condenser coil with aluminium, coated aluminium, copper or tinned copper fins Wide operating limits - Maximum external air temperature: 44C for size 2802 and for sizes from 5002 up to 5702 46C for all other sizes - Ability to exceed operating limits with a reduction of capacity using an intelligent algorithm that avoids a fault trip-out Low sound level Low noise axial fans with aerodynamic profile blades Acoustical compressor enclosure as standard For the low-noise versions: - Hot gas discharge muffler - Optional acoustic kit AK, including enhanced soundproofing enclosures and additional insulation DCPX as standard: fan speed control by means of phase-cut controller

Accessories
AER 485P1: RS-485 interface for supervision systems with MODBUS protocol. AVX: Spring anti-vibration mounts KRS: (obligatory accessory with version ). Evaporator trace heating. Factory fitted only. KDI: 20 mm doubled thickness evaporator insulation. Provides stand-still protection down to -20C. Must be ordered in conjunction with options KRS. GP: Protective grille. Condenser coil external protection against accidental or hail damage. Factory fitted. PRV3: Remote control of the chiller operating functions. RIFNS: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted AK: ACOUSTIC KIT (only for Versions E). only. For compatibility of the RIF device refer This accessory allows further sound reduction. Must be requested at time of order and to the technical manual. is available factory fitted only. AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an MULTICHILLER: Control system for multiple parallel installed constant flow chillers proethernet connection over a common browser; 4 viding individual chiller on/off and control versions available: capability. AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem;

228

Compatibility Accessories
Mod. NS_W_B AER485P1 MULTICHILLER AK-ACUSTIC KIT (1)(3) PRV3 AERWEB300 Mod. NS_W_B AER485P1 MULTICHILLER AK-ACUSTIC KIT (1)(3) PRV3 AERWEB300 Mod. NS_W_B GP 300M (1) GP 400M (1) GP 500M (1) GP 300B (1) GP 400B (1) GP 500B (1) GP 300M+300M (1) KRS (1) Mod. NS_W_B_A/E GP 300M+300M (1) GP 300M+400M (1) GP 400M+400M (1) GP 400M+500M (1) GP 500M+500M (1) GP 400M+400M+500M GP 400M+500M+500M GP500M+500M+500M KRS (1) Mod. NS_W_B_A/E AVX RIFNS (1)(2) Mod. NS_W_B_A/E AVX RIFNS (1)(2) Mod. NS_W_B_A/E KDI (x n) (4) Mod. NS_W_B_A/E KDI (x n) (4) Mod. NS_W_B_A/E KDI (x n) (4) Mod. NS_W_B_A/E KDI (x n) (4) 1251 (x1) 3202 (x2) 1251 1401 (x1) 3402 (x2) 1401 1601 (x1) 3602 (x2) 1601 1801 (x1) 3902 (x2) 1801 KRS10 3202 KRS10 3402
(1) (1) (1)

2101 (x1) 4202 (x2) 2101

2401 (x1) 4502 (x2) 2401

1402 (x2) 4802 (x2) 1402

1602 (x2) 5002 (x2) 1602

1802 (x2) 5202 (x2) 1802

2002 (x2) 5402 (x2) 2002

2202 (x2) 5702 (x2) 2202

2352 (x2) 6003 (x3) 2352

2502 (x2) 6303 (x3) 2502

2652 (x2) 6603 (x3) 2652

2802 (x2) 6903 (x3) 2802

3002 (x2) 7203 (x3) 3002

KRS11 5702

KRS11 6003

KRS11 6303

KRS11 6603

KRS11 6903 KRS13 7203

KRS11 3602

KRS10 3902

KRS11 4202

KRS11 4502

KRS11 4802

KRS11 5002

KRS10 5202

KRS10 5402

KRS16 2652 6603 KRS17 2802 6903 KRS17 3002 7203

KRS14 1251 3202

KRS13 1401 3402

KRS12 1601 3602

KRS13 1801 3902

KRS13 2101 4202

KRS14 2401 4502

KRS14 1402 4802

KRS14 1602 5002 2101 KDI04 2652 KDI08 4802 KDI04 x2 7203 KDI04 x3
(4) Accessory

KRS14 1802 5202

KRS14 2002 5402

KRS14 2202 5702

KRS15 2352 6003

KRS16 2502 6303

1251 KDI01 2002 KDI06 3602 KDI03 x2 6003 KDI03 x2+KDI04

1401 KDI01 2202 KDI08 3902 KDI03+KDI04 6303

1601 KDI02 2352 KDI08 4202 KDI03+KDI04 6603

1801 KDI03 2502 KDI08 4502 KDI04 x2 6903 KDI04 x3

2401 KDI04 2802 KDI08 5002 KDI04+KDI05

1402 KDI06 3002 KDI01+KDI02 5202 KDI05 x2

1602 KDI06 3202 KDI02 x2 5402 KDI05 x2

1802 KDI06 3402 KDI02+KDI03 5702 KDI05 x2

KDI03+KDI04 x2 KDI03+KDI04 x2

Notes: (1) Accessory only factory fitted. Number in brackets, i.e. (x1) indicates quantity. (2) Accessory only available with 400V-3-50Hz power supply (3) Accessory only available for low noise versions

KDI must always be combined with the KRS heating elements. KRS (obligatory accessory version )

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.
Field key:

12 Code

3456 Size

7 Expansion device

8 Model

9 Heat recovery

10 Version

11 Condenser coil

12
Fan

13
Power supply

14 15
Pump assembly

Code: NS Sizes: 1251, 1401, 1601, 1801, 2101, 2401, 1402, 1602, 1802, 2002, 2202 2352, 2502, 2652, 2802,3002, 3202,3402, 3602, 3902,4202,4502, 4802, 5002, 5202, 5402, 5703, 6003, 6303, 6603, 6903, 7203 Expansion device W - Electronic expansion valve, leaving water temperature from +5C up to +30C Modell: B - Free-cooling Glycol-free Heat recovery - Without heat recovery Version: A - High Efficiency E - High efficiency low noise version Coil: - Alluminium R - Copper S - Tinned copper V - Anti-corrosion coated aluminium Fan: - Standard M - High static pressure * not available in sizes from 1251 up to 1601 and from 3002 up to 3402 Pump assembly option not available in sizes 1402, 1602, 2002

J - Inverters
Power supply:

- 400V 3~ 50Hz with fuses 8 - 400V 3~ 50Hz with circuit breakers Pump assembly: 00 - Without pump assembly PA - Pump assembly (Pump A) PB - Pump assembly (Pump A and standby pump) * PC - Pump assembly (Pump C) PD - Pump assembly (Pump C and standby pump) * PE - Pump assembly (Pump E) PF - Pump assembly (Pump E and standby pump) * PG - Pump assembly (Pump G) PH - Pump assembly (Pump G and standby pump) * PJ - Pump assembly (Pump J) PK - Pump assembly (Pump J and standby pump) *

229

Technical Data
Mod. NS_W_B Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total air temperature free-cooling Total input current Water flow rate Compressors Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (Chiller) Sound pressure (Freecooling) Air flow rate (Chiller) Air flow rate (Freecooling) Fans Evaporators (1) Mod. NS_W_B Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total air temperature free-cooling Total input current Water flow rate Compressors Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (Chiller) Sound pressure (Freecooling) Air flow rate (Chiller) Air flow rate (Freecooling) Fans Evaporators(1) Mod. NS_W_B Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total air temperature free-cooling Total input current C C A A kW kW kW C C A l/h n dB(A) dB(A) dB(A) dB(A) m3/h m3/h n n U.M. kW kW A kW kW kW C C A l/h n dB(A) dB(A) dB(A) dB(A) m3/h m3/h n n U.M. kW kW A kW kW kW U.M. kW kW Vers. BA BE BA BE BA BE BA BE BA BE BA /BE BA BE BA BE BA /BE BA BE Tutte % BA BE BA BA BE BA BA BE BA All All Vers. BA BE BA BE BA BE BA BE BA BE BA /BE BA BE BA BE BA /BE BA BE All % BA BE BA BA BE BA BA BE BA All All Vers. BA BE BA BE BA BE BA BE BA BE BA /BE BA BE BA BE BA /BE 1251 265 251 71 73 3,73 3,44 123 125 265 251 14,0 18,9 17,9 8,6 8,7 28 45580 43172 1 25-100 94 86 94 62 54 62 102000 70000 102000 6 1 2002 445 419 118 122 3,77 3,43 208 212 445 419 25,3 17,6 16,6 8,1 7,9 51 76540 72068 2 25-100 98 90 98 66 57 66 170000 124500 170000 10 1 3602 796 734 202 212 3,94 3,46 358 370 796 734 39,6 20,1 18,5 8,1 8,7 79 1401 306 286 83 86 3,69 3,33 142 147 306 286 14,0 21,9 20,4 7,2 7,8 28 52632 49192 1 25-100 95 87 95 63 55 63 102000 78000 102000 6 1 2202 472 436 122 126 3,87 3,46 212 217 472 436 25,3 18,7 17,2 8,4 9,0 51 81184 74992 2 25-100 98 90 98 66 58 66 170000 120000 170000 10 1 3902 857 791 214 223 4,00 3,55 375 386 857 791 45,1 19,0 17,5 8,4 8,9 90 1601 331 307 88 94 3,76 3,27 157 163 331 307 14,0 23,6 21,9 6,6 7,5 28 56932 52804 1 25-100 97 89 97 65 57 65 102000 87000 102000 6 1 2352 493 461 133 139 3,71 3,32 229 236 493 461 25,4 19,4 18,1 8,1 8,5 51 84796 79292 2 25-100 98 90 98 66 58 66 170000 123000 170000 10 1 4202 912 839 230 241 3,97 3,48 413 426 912 839 45,3 20,1 18,5 7,9 8,5 91 1801 398 367 101 106 3,94 3,46 179 185 398 367 19,8 20,1 18,5 8,1 8,7 40 68456 63124 1 25-100 97 89 97 65 57 65 136000 100000 136000 8 1 2502 520 483 143 150 3,64 3,22 245 254 520 483 25,5 20,4 18,9 7,5 8,1 51 89440 83076 2 25-100 98 90 98 66 58 66 170000 130000 170000 10 1 4502 973 896 242 252 4,02 3,56 430 442 973 896 50,8 19,2 17,6 8,1 8,7 102 2101 459 424 113 117 4,06 3,62 196 201 459 424 25,3 18,1 16,8 8,6 9,1 51 78948 72928 1 25-100 98 90 98 66 58 66 170000 112000 170000 10 1 2652 550 509 155 164 3,55 3,10 265 277 550 509 27,1 20,3 18,8 7,0 7,7 54 94600 87548 2 25-100 99 91 99 67 59 67 170000 130000 170000 10 1 4802 1028 944 258 270 3,98 3,50 468 482 1028 944 51,0 20,2 18,5 7,6 8,4 102 2401 514 472 129 135 3,98 3,50 234 241 514 472 25,5 20,2 18,5 7,6 8,4 51 88408 81184 1 25-100 98 90 98 66 58 66 170000 127000 170000 10 1 2802 574 543 167 177 3,44 3,07 284 298 574 543 27,2 21,1 20,0 6,6 7,2 54 98728 93396 2 25-100 99 91 99 67 59 67 170000 140000 170000 10 1 5002 1087 1003 281 296 3,87 3,39 496 514 1087 1003 51,0 21,3 19,7 6,7 7,6 102 1402 304 285 80 85 3,80 3,35 148 152 304 285 14,0 21,7 20,4 7,0 6,1 28 52288 49020 2 25-100 96 88 96 64 56 64 102000 74000 102000 6 1 3002 637 593 171 180 3,73 3,29 299 310 637 593 28,0 22,8 21,2 6,9 7,6 56 109564 101996 2 25-100 99 91 99 66 58 66 204000 165000 204000 12 2 5202 1146 1062 304 322 3,77 3,30 524 546 1146 1062 51,0 22,5 20,8 6,1 6,9 102 1602 340 314 98 103 3,47 3,05 174 181 340 314 14,0 24,3 22,4 6,0 6,8 28 58480 54008 2 25-100 97 89 97 65 57 65 102000 80000 102000 6 1 3202 662 614 176 188 3,76 3,27 314 326 662 614 28,0 23,6 21,9 6,6 7,5 56 113864 105608 2 25-100 100 92 100 67 59 67 204000 174000 204000 12 2 5402 1205 1113 332 354 3,63 3,14 568 596 1205 1113 51,0 23,6 21,8 5,6 6,4 102 1802 411 382 110 114 3,74 3,35 196 201 411 382 19,8 20,8 19,3 7,3 7,8 40 70692 65704 2 25-100 97 89 97 65 57 65 136000 96000 136000 8 1 3402 729 674 189 200 3,86 3,37 336 348 729 674 33,8 21,6 19,9 7,4 8,1 68 125388 115928 2 25-100 100 92 100 67 59 67 238000 187000 238000 14 2 5702 1264 1164 360 386 3,51 3,02 612 646 1264 1164 51,0 24,8 22,8 5,0 5,9 102

SOUND POWER: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 96142, as required for Eurovent certification.

SOUND PRESSURE: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

230

Technical Data
Mod. NS_W_B Water flow rate Compressors Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (chiller) Sound pressure (freecooling) Air flow rate (chiller) Air flow rate (freecooling) Fans Evaporators (1) Mod. NS_W_B Cooling capacity Total input power E.E.R. Total input current Cooling capacity Total input power EER Total air temperature free-cooling Total input current Water flow rate Compressors Capacity control Sound power (chiller) Sound power (freecooling) Sound pressure (Chiller) Sound pressure (Freecooling) Air flow rate (Chiller) Air flow rate (Freecooling) C C A l/h n dB(A) dB(A) dB(A) dB(A) m3/h m3/h n n U.M. l/h n dB(A) dB(A) dBA dBA m3/h m3/h n n U.M. kW kW W/W A kW kW kW Vers. BA BE All % BA BE BA BA BE BA BA BE BA All All Vers. BA BE BA BE BA BE BA BE BA BE BA /BE BA BE BA BE BA /BE BA BE All % BA BE BA BA BE BA BA BE BA All All 3602 136912 126248 2 25-100 100 92 100 67 59 67 272000 200000 272000 16 2 6003 1310 1206 331 347 3,96 3,48 592 611 1310 1206 65,1 20,1 18,5 7,9 8,6 130 225320 207432 3 25-100 102 94 102 3902 147404 136052 2 25-100 101 93 101 68 60 68 306000 212000 306000 18 2 6303 1371 1263 343 358 4,00 3,53 609 627 1371 1263 70,6 19,4 17,9 8,1 8,7 141 235812 217236 3 25-100 102 94 102 4202 156864 144308 2 25-100 101 93 101 68 60 68 306000 227000 306000 18 2 6603 1426 1311 359 376 3,97 3,49 647 667 1426 1311 70,8 20,1 18,5 7,8 8,5 142 245272 225492 3 25-100 103 95 103 4502 167356 154112 2 25-100 101 93 101 68 60 68 340000 239000 340000 20 2 6903 1487 1368 371 387 4,01 3,53 664 683 1487 1368 76,3 19,5 17,9 7,9 8,6 153 255764 235296 3 25-100 103 95 103 4802 176816 162368 2 25-100 101 93 101 68 60 68 340000 254000 340000 20 2 7203 1542 1416 387 405 3,98 3,50 702 723 1542 1416 76,5 20,2 18,5 7,6 8,4 153 265224 243552 3 25-100 103 95 103 5002 186964 172516 2 25-100 102 94 102 69 61 69 340000 254000 340000 20 2
(1)

5202 197112 182664 2 25-100 102 94 102 69 63 69 340000 254000 340000 20 2

5402 207260 191436 2 25-100 102 94 102 69 63 69 340000 254000 340000 20 2

5702 217408 200208 2 25-100 102 94 102 69 63 69 340000 254000 340000 20 2

= Shell & tube Power supply = 400V 3~ 50 Hz. Performance values refer to the following conditions: Chiller: - entering water temperature 25 C - leaving water temperature 20 C - external air temperature 35 C - t = 5 C. Free-cooling glycol free - temperatura acqua Ingresso 25C - primary circuit glycol 30% - secondary circuit glycol 0% Sound power: Aermec determines the value of sound power on the basis of measurements made in accordance with ISO 9614-2, as required for Eurovent certification. Sound pressure: Measured in free field over a reflective plane (directivity factor Q = 2), at a distance of 10 metres from the outer surface of the unit, in accordance with ISO 3744.

69 62 69
442000 327000 442000 26 3

69 62 69
476000 339000 476000 28 3

70 63 70
476000 354000 476000 28 3

69 63 69
510000 366000 510000 30 3

69 63 69
510000 381000 510000 30 3

Fans Evaporators (1)

Dimensions (mm)
Mod.NS_W_B Height Width Lenght Weight Mod.NS_W_B Height Width Lenght Weight Mod.NS_W_B Height Width Lenght Weight Mod.NS_W_B Height Width Lenght Weight (A) (B) (C) kg (A) (B) (C) kg (A) (B) (C) kg (A) (B) (C) kg 1251 2450 2200 3780 3596 1602 2450 2200 3780 4158 2802 2450 2200 5750 5989 4502 2450 2200 11100 10611 1401 2450 2200 3780 3610 1802 2450 2200 4770 4887 3002 2450 2200 7160 7169 4802 2450 2200 11100 10818 1601 2450 2200 3780 3968 2002 2450 2200 5750 5360 3202 2450 2200 7160 7566 5002 2450 2200 11100 12104 1801 2450 2200 4770 4779 2202 2450 2200 5750 5431 3402 2450 2200 8150 8308 5202 2450 2200 11100 12710 2101 2450 2200 5750 5708 2352 2450 2200 5750 5968 3602 2450 2200 9140 8738 5402 2450 2200 11100 12783 2401 2450 2200 5750 5729 2502 2450 2200 5750 5944 3902 2450 2200 10120 10117 5702 2450 2200 11100 12856 1402 2450 2200 3780 3796 2652 2450 2200 5750 5975 4202 2450 2200 10120 10388 6003 2450 2200 14490 14467

A/E A/E

A/E A/E

C B

A/E A/E

A/E A/E

For transport reasons NS GLYCOLFREE HWT sizes 6003 to 7203 are shipped separated; one module consisting of two compressors and standard electrical panel (placed in front of the unit) and one module with one compressor and the electrical panel placed on the
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

compressor side beneath the condenser coil. On the site it is only necessary to connect the two sections electrically. For more information refer to the technical and/or installation manual.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Fax 044293730 www.aermec.com

231

Cod.: SNSGFHWTUY.00 / 0113

6303 2450 2200 15470 15846

6603 2450 2200 15470 16117

6903 2450 2200 16450 16298

7203 2450 2200 16450 16505

PRELIMINARY

NSI

Air cooled chillers INVERTER screw compressors, axial fans Cooling capacity from 262 to 1249 kW

R134a
HIGH

Aermec participate in the EUROVENT program:LCP/A/P/C, up to 600 kW the products are present on the site www.eurovent-certification.com * Not certified model

SEASONAL
EFFICIENCY

New generation INVERTER screw compressor

Features
Available in 14 sizes Cooling only version Refrigerant R134a New generation INVERTER screw compressor: - Continuous capacity control from 15 to 100% - With automatic control of compression ratio - With opto-electronic control of oil level AC Inverter: - Refrigerant cooled - With control of operating field - With integrated data logger High efficiency version A Operating limit up to 46 C external air temperature Compressor acoustical enclosure for low noise operation Electronic expansion valve Dry expansion shell and tube evaporator optimised for refrigerant R134a Extremely low noise axial fans with options: - M high static pressure fans - J inverter fans P u m p a s s e m b l y o p t i o n ( s e e U n i t Configurator) that includes: - 1 pump - 1 pump plus 1 standby - 2 expansion tanks of 25 litres Microprocessor controller Multilingual display Compact dimensions Metal control panel with anti-corrosion polyester paint.

Accessories
AER485P1: RS-485 interface for supervision systems with MODBUS protocol. AVX: Spring anti-vibration mounts. For compatibility of the AVX mounts refer to the technical manual. DCPX: Low ambient device for cooling operation below 19 C down to -10 C. Standard for Versions D, L, and E. KRS: Evaporator trace heating. Factory fitted only. GP: Protective grille. Condenser coil external protection against accidental or hail damage. Factory fitted. PRV3: Remote control of the chiller operating functions. RIFNS: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted only. For compatibility of the RIF device refer to the technical manual. AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; MULTICHILLER: Control system for multiple parallel installed constant flow chillers providing individual chiller on/off and control capability.

232

Accessory compatibility

GP300M * GP400M * GP500B * GP300M+GP300M * GP400M+GP400M * GP300M+GP300M+GP300M * GP400M+GP400M+GP400M * DCPX KRS

1 1 1 1 1 1 1 2

1251

1401

1601

1701

1801

2502

2802

3202

3402

3602

4203

4803

5103

5403

73+69 73+69 73+76 73+76

69

69

69

69

69

73

73

73

73

73

1. 2.

Accessory only factory fitted Accessory available for all sizes, to t contact factory

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system requirements. Configuration fields: 123 4567 8 9 10 11 12 13 14 15-16 | | | | | | | | | | Code | Expansion | Heat recovery | | | | | | device | | Condenser coil | Power supply | Size Model Version Fan Pump Code: NSI Size: 1251, 1401, 1601, 1701, 1801, 2502, 2802, 3202, 3402, 3602, 4203, 4803, 5103, 5403 Expansion device: X - R134a electronic expansion valve, minimum leaving water temperature down to +4 C (for lower temperatures contact the factory) Model: - Cooling only Heat recovery: - Without heat recovery Version: A - High efficiency Condenser coil: - Aluminium R - Copper S - Tinned copper V - Anti-corrosion coated aluminium Fan: - Standard M - High static pressure J - Inverter Power supply: - 400V/3/50Hz with fuses Pump: 00 - Without pump assembly PA - Pump assembly (Pump A) PB - Pump assembly (Pump A and standby pump) PC - Pump assembly (Pump C) PD - Pump assembly (Pump C and standby pump) PE - Pump assembly (Pump E) PF - Pump assembly (Pump E and standby pump) PG - Pump assembly (Pump G) PH - Pump assembly (Pump G and standby pump) PJ - Pump assembly (Pump J) PK - Pump assembly (Pump J and standby pump)

233

Technical Data
Mod. NSI Cooling capacity Total input power Water ow rate Pressure drop EER ESEER Power supply Total input current Maximum current (FLA) Starting current (LRA) Capacity control Compressors Refrigerant Refrigerant circuits Air ow rate Fans Evaporator Sound power Maximum external air temp. Mod. NSI Cooling capacity Total input power Water ow rate Pressure drop EER ESEER Power supply Total input current Maximum current (FLA) Starting current (LRA) Capacity control Compressors Refrigerant Refrigerant circuits Air ow rate Fans Evaporator Sound power Maximum external air temp.
* Not certified model EUROVENT Vers

A A A A A A A A A A A A A A A A A A

kW kW l/h kPa W/W W/W V/ph/Hz A A A % type n tipo n m3/h type n type n dB(A) C

1251 262 88 45240 36,0 2,98 4,69 140 180 18 24-100 1 1 116000 6 1 94,9 46 *3202 666 224 114730 25,2 2,97 4,64 358 483 121 9-100 2 2 212000 12 2 101,5 46

1401 302 100 52110 46,9 3,02 4,68 159 211 18 20-100 1 1 110000 6 1 96,7 46 *3402 748 253 128970 37,1 2,95 4,63 403 550 126 9-100 2 2 290000 16 2 101,2 46

1701 1801 374 416 127 140 64490 71800 37,1 33,5 2,95 2,97 4,63 4,67 430/3/50Hz 179 202 223 242 275 309 18 20 20 18-100 17-100 15-100 screw - inverter 1 1 1 R134a 1 1 1 106000 145000 136000 Axial 6 8 8 shell and tube evaporator 1 1 1 98,5 98,2 97,8 46 46 46 *3602 833 280 143600 33,5 2,98 4,67 *4203 *4803 906 999 299 337 156340 172100 46,9 25,2 3,03 2,97 4,76 4,64 430/3/50Hz 446 476 537 618 632 725 126 225 225 9-100 7-100 7-100 screw - inverter 2 3 3 R134a 2 3 3 272000 330000 318000 Axial 16 18 18 shell and tube evaporator 2 3 3 100,8 101,5 103,3 46 46 46

1601 333 112 57370 25,2 2,96 4,64

2502 526 173 90720 47,3 3,03 4,78 275 357 119 12-100 2 2 180000 10 1 97,9 46 *5103 1122 380 193460 37,1 2,95 4,63 605 825 232 7-100 3 3 435000 24 3 103,0 46

2802 591 199 102170 58,8 2,97 4,69 315 416 119 12-100 2 2 173000 10 1 99,7 46 *5403 1249 420 215410 33,5 2,98 4,67 669 927 232 7-100 3 3 408000 24 3 102,6 46

Vers

A A A A A A A A A A A A A A A A A A

kW kW l/h kPa W/W W/W V/ph/Hz A A A % type n type n m3/h type n type n dB(A) C

Data declared in accordance with UNI EN 14511:2011 COOLING MODE Entering water temperature Leaving water temperature External air temperature

12 C 7 C 35 C

Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

234

Dimensions (mm)

Mod. NSI Height Width Lenght Weight empty

A B C

mm mm mm kg

1251 2450 2200 3780 2979

1401 2450 2200 3780 3082

1601 2450 2200 3780 3252

1701 2450 2200 4770 3763

1801 2450 2200 4770 3956

2502 2450 2200 5750 5407

2802 2450 2200 5750 5562

3202 2450 2200 7160 6493

3402 2450 2200 9140 7464

3602 2450 2200 9140 7850

4203 2450 2200 10540 9194

4803 2450 2200 10540 9704

5103 2450 2200 13510 11155

5403 2450 2200 13510 11734

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

235

Cod.: snsiuy.01/ 1301

TBX
R134a

Air cooled chillers with two-stage centrifugal compressor and axial fans Cooling capacity from 259 to 861 kW

SEASONAL
Aermec participates in the EUROVENT: LCP/A/P/R programme, up to 600 kW The products are listed on the site www.eurovent-certification.com * not certified models

HIGH

EFFICIENCY

Characteristics
Available in 12 sizes Cooling only version New generation two-stage oil-free centrifugal compressor with magnetic levitation bearings Refrigerant R134a Exceptional high efficiency at part load (up to 30% higher ESEER compared to standard chillers) Electronic expansion valve for precise control Flooded shell and tube evaporator optimised for refrigerant R134a Axial fans for extremely quiet operation Compressor features: 1. Operates without oil as bearings are magnetic levitation type. Vibration free and very quiet 2. Provided with inverter technology that permits capacity modulation down to 25% 3. Integrated controller that reduces starting current to 6 A only Standard and Low noise L Versions: 1. Operating limit up to 42 C external air temperature 2. Compressor acoustical enclosure for low noise operation 3. Fan speed control High efficiency A and High efficiency low noise E Versions: 1. Operating limit up to 42 C external air temperature 2. Compressor acoustical enclosure for low noise operation 3. EC (Electronically Commutated) fan Modulating capacity control microprocessor system Evaporator trace heating. LCD user interface: colour touch-screen with simple and intuitive graphical menu Multilingual display panel Compact sizes Metal control panel with anti-corrosion polyester paint

Accessories
AER485P1: RS-485 interface for supervision Factory fitted. systems with MODBUS protocol. PTW: Remote control of the chiller operating AVX: Spring anti-vibration mounts. For comfunctions. patibility of the AVX mounts refer to the technical manual. GP: Protective grille. Condenser coil external protection against accidental or hail damage.

236

TBX AER485P1 AERWEB300-6 AERWEB300-18 AERWEB300-6G AERWEB300-18G GP300M GP400M GP500M GP 300M+300M GP 300M+400M GP 400M+400M GP 400M+500M GP 500M+500M GP 300M GP 400M GP 500M GP 300M+300M GP 300M+400M GP 400M+400M GP 400M+500M GP 500M+500M AVX

VERS. All All All All All L|E L|E L|E L|E L|E L|E L|E L|E |A |A |A |A |A |A |A |A L A E

1401 (x1)

1801 (x1)

2001 (x1)

2302 (x2)

2502 (x2)

2652 (x2)

2802 (x2)

3202 (x2)

3502 (x2)

3702 (x2)

3802 (x2)

4102 (x2)

570 570 570 570 571 571 571 571 571 571 571 571 572 572 572 572 573 573 573 573 574 574 574 574 575 575 575 575 575 575 575 575 576 575 576 575 576 576 576 576 577 576 578 576 577 577 578 577

Note: The number in brackets (x2) indicates the quantity to order. AER485P1 - GP Accessory only factory fitted.

Unit Configurator
Combinando opportunamente le numerose opzioni disponibili, possibile configurare ciascun modello in modo tale da soddisfare le pi specifiche esigenze impiantistiche. Configuration fields: 123 4 5 6 7 8 9 10 11 12 | | | | | | | Code | Model | Condenser coil | | | | | Power supply Size Version Fan

Code: TBX Size: 1401, 1801, 2001, 2302, 2502, 2652, 2802, 3202, 3502, 3702, 3802, 4102 Model: - Cooling only, with evaporator to PED regulations Version: - Standard L - Standard low noise A - High efficiency E - High efficiency low noise Condenser coil: - Aluminium R - Copper S - Tinned copper V - Anti-corrosion coated aluminium

Fan: - Standard I - EC (Electronically Commutated) standard on A and E Versions Power supply: - 400V 3~ 50Hz with circuit breakers Note: Electronic expansion valve standard

237

Technical Data
1401 1801 2001 2302 kW 287 368,3 407,3 469,3 kW 258,8 342,8 392,1 435,7 Cooling capacity kW 286,8 370,7 415,5 460,4 kW 265,2 354,8 406,4 441,2 kW 91,8 117,2 129,3 149 kW 88,9 117,9 134,7 149,6 Total input power kW 86 110,9 124,8 138,1 kW 84,8 113,6 130,2 141,2 l/h 49536 63468 70176 80840 l/h 44646 59065 67577 75047 Evaporator water flow rate l/h 49536 63984 71724 79464 l/h 45790 61229 70176 76141 kPa 36 17 15 15 kPa 30 15 19 13 Evaporator pressure drop kPa 50 41 43 44 kPa 44 38 49 40 W/W 3,13 3,14 3,15 3,15 W/W 2,91 2,91 2,91 2,91 EER W/W 3,33 3,34 3,33 3,33 W/W 3,13 3,12 3,12 3,13 W/W 4,82 4,92 4,95 5,12 W/W 4,69 4,77 4,76 4,97 ESEER W/W 5,01 5,06 5,04 5,33 W/W 4,85 4,89 4,82 5,15 Power supply V/ph/Hz A 147 195 216 242 L A 144 198 225 244 Total input current A A 134 179 200 217 E A 132 176 209 221 A 153 234 240 300 L A 153 234 240 300 Maximum input current (FLA) A A 159 242 250 310 E A 159 242 250 310 A 24 30 36 126 L A 24 30 36 126 Maximum starting current (LRA) 30 38 46 136 A A E A 30 38 46 136 A Capacity modulation A 30-100 30-100 30-100 15-100 type Compressor n 1 1 1 2 Refrigerant type Refrigerant circuit n 1 1 1 1 |A m3/h 94200 132800 166000 166000 Air flow rate L|E m3/h 69720 92960 116200 116200 |L type A|E type Fan L|E type 6 8 10 10 |A type 6 8 10 10 type Evaporator n 1 1 1 1 Electric heater n/W 1/170 1/250 1/250 1/250 Maximum external air C 42 42 42 42 temperature |A dB(A) 88 89 90 90 Sound power L dB(A) 83 84 85 85 81 82 83 83 E dB(A) |A dB(A) 56 57 58 58 Sound pressure L dB(A) 51 52 53 53 E dB(A) 49 50 51 51 L A E L A E L A E L A E L A E L A E
* Unit not EUROVENT certified

Mod. TBX

2652 2802 3202* 545,2 587,2 669,1 518,3 543,2 595 538,1 594,1 667,8 532,5 556 614 173 184,9 212,2 177,5 186,2 203,8 161,1 177,3 199,7 170,3 177 196,9 93912 101136 115240 89292 93568 102495 92880 102512 115240 91931 95976 105966 15 14 15 16 15 15 44 41 43 48 46 44 3,15 3,18 3,15 2,92 2,92 2,92 3,34 3,35 3,34 3,13 3,14 3,12 5,13 5,18 5,14 4,96 5,00 4,97 5,35 5,38 5,37 5,13 5,15 5,16 400V/3/50Hz 260 280 299 355 258 287 308 345 235 251 276 322 238 265 275 320 300 306 312 462 300 306 312 462 310 318 326 476 310 318 326 476 126 132 138 188 126 132 138 188 136 144 152 202 136 144 152 202 stepless 15-100 15-100 15-100 15-100 centrifugal inverter oil-free 2 2 2 2 R134a 1 1 1 1 157000 199200 232400 232400 109900 139440 162680 162680 axial Axial EC (Electronically Commutated) 10 12 14 14 10 12 14 14 ooded shell & tube 1 1 1 1 1/250 1/250 1/250 1/250 42 90 85 83 58 53 51 42 91 86 84 58 53 51 42 92 87 85 59 54 52 42 92 87 85 59 54 52

2502 509,2 463,9 502,2 473,6 161,4 159,3 150,4 152,2 87720 79911 86688 81755 15 15 44 46 3,16 2,91 3,34 3,11 5,14 4,97 5,35 5,13

3502* 736 635,3 739,5 650,4 233,3 217,7 220,8 207,8 126764 109444 127624 112282 16 17 45 49 3,15 2,92 3,35 3,13 5,14 4,97 5,37 5,14 389 366 355 337 468 462 484 476 194 188 210 202

3702* 780,9 687,8 793,3 707,4 247,4 236,3 237,3 226,5 134504 118477 136912 122106 17 16 46 47 3,16 2,91 3,34 3,12 5,14 4,98 5,36 5,15 412 396 382 366 474 468 492 484 200 194 218 210

3802* 815,9 742,3 831,2 768,4 258,8 255 248,4 246,1 140524 127858 143448 132633 15 16 45 48 3,15 2,91 3,35 3,12 5,15 4,97 5,37 5,15 431 426 399 396 480 474 500 492 206 200 226 218

4102* 844,8 784,6 861 813,1 268,2 269 258,1 260,1 145512 135154 148608 140352 16 17 48 48 3,15 2,92 3,34 3,13 5,14 4,96 5,34 5,14 447 449 413 417 480 480 500 500 206 206 226 226

15-100 15-100 15-100 15-100 2 2 2 2

1 1 1 1 265600 298800 332000 314000 153860 185920 209160 232400

16 14 1 1/250 42 93 87 85 60 54 52

18 16 1 1/250 42 93 88 86 60 55 53

20 18 1 1/250 42 93 88 86 60 55 53

20 20 1 1/250 42 93 88 86 60 55 53

Data in accordance with EN14511-2:2011 Cooling Entering water temperature Leaving water temperature External air temperature

12C 7C 35C

Sound power: Aermec determines the value of sound power on the basis of measurements made in accordance with ISO 9614-2, as required for Eurovent certification.

Sound pressure: Measured in free field over a reflective plane (directivity factor Q = 2), at a distance of 10 metres from the outer surface of the unit, in accordance with ISO 3744.

238

Dimensions (mm)

Model. TBX Height A Width B Length

All All |A L|E

mm mm mm mm

1401 2.450 2.200 3.780 3.780

1801 2.450 2.200 4.770 4.770

2001 2.450 2.200 5.750 5.750

2302 2.450 2.200 5.750 5.750

2502 2.450 2.200 5.750 5.750

2652 2.450 2.200 7.160 7.160

2802 2.450 2.200 8.150 8.150

3202 2.450 2.200 8.150 8.150

3502 3702 3802 2.450 2.450 2.450 2.200 2.200 2.200 9.140 10.120 11.100 8.150 9.140 10.120

4102 2.450 2.200 11.100 11.100

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

239

Cod.: STBXUY.04 / 1301

IDROBLOC
R407C

Air cooled chiller with axial fan With capacity from 3.5 up to 6.7 kW

IDROBLOC is a low-consumption water chiller assembly designed for outdoor installation, sized to provide a water flow sufficient to run a relatively high number of terminal units. The thermal head of water to the evaporator can be contained to 2.5C; in practical terms, this means that the system can run fancoils in all rooms, though only operating the ones located in rooms that are occupied. The user can select which of the fancoils installed are to be activated, simply by turning individual units on or

off, without ever having to adjust the water distribution circuit. IDROBLOC may be installed on the ground or wall-mounted. With a size similar to that of regular outdoor water boilers, the IDROBLOC is perfectly suited for new or restructured domestic applications.

IDROBLOC IDROBLOC H

Features
Unit for roof-hanging or floor-standing installation with brackets supplied (only for IDROBLOC and IDROBLOC H) All versions are supplied for use with R407C Cooling only and heat pump version Compact dimensions Helical fan unit with axial delivery Evaporator dimensioned for working with t = 2.5 C Antifreeze electric heater for the storage tank environments, keeping in operation only Hydraulic circuit complete with pump, those relative to rooms that are occupied expansion tank, storage tank, water filter, flow Electric power used within the standard switch and safety valve domestic availability limits Adjustment and control fully electronic with Extreme simplicity of installation microprocessor card Pre-arrangement for coupling with boiler, with immediate seasonal switching Possibility of powering the fan coils of all the

Accessories
DCPX: (only for IDROBLOC) Low temperatuand off, signalling of alarms and season chancable up to 150 m. re device for correct cooling mode operation geover). Can be made remote with shielded SDP: Electronic card for using PR3 accessory with ambient temperatures from less than cable up to 30 m. up to a distance of 150 m. 20C down to - 10C. PRD1 : Smart remote panel. Repeats at a VT7: Anti-vibration mounts. PR3: Simplified remote panel. Allows basic distance the functions of the panel on the machine checks to be carried out (turning on machine. Can be made remote with shielded Compatibility of accessories
IDROBLOC 3-5 3H-5H DCPX 42 PR 3 PRD 1 SDP VT 7

Installation
IDROBLOC is quick and simple to install: simply position the unit, then make all water and electrical connections. The unit can be connected to any type of heating assembly: autonomous or centralised boiler, or district (remote) heating systems.

IDROBLOC Free-standing
DISTRICT HEATING SYSTEM INDIPENDENT HEATING SYSTEM CENTRALIZED HEATING SYSTEM

IDROBLOC Wall-mounted

240

Technical data
IDROBLOC Cooling capacity Total input power* Input current* Evaporator water flow rate Effective head Heating capacity Total input power* Input current* Evaporator water flow rate Effective head e Sound pressure Total air flow rate Compressors Peak current (compressor) Storage tank capacity Expansion tank capacity Pump speed Water connections (female Gas) Power supply = 230V ~ 50Hz. Performance values refer to the following conditions: Cooling: - water outlet temperature 7 C; - ambient air temperature 35 C - t = 5 C. Riscaldamento: - water outlet temperature 50 C; - ambient air temperature 7 C D.B., 6 C W.B.;.; - t = 5 C. Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744) * = included the absorption of the circulation pump kW kW A l/h (nominal) l/h (max.) kPa (nominal) kPa (max.) kW kW A l/h (nominal) l/h (max.) kPa (nominal) kPa (max.) dB (A) m3/h n type A l l n. (installation) (heating) 3 3,5 1,5 7,3 600 2000 69 32 33,5 1200 1 33,5 25 1 3 3/4 1/2 3H 3,2 1,5 7,3 550 2000 69 59 3,85 1,45 7,2 660 2000 67 55 33,5 1200 1 33,5 25 1 3 3/4 1/2 5 6,7 2,8 13,2 1150 2000 58 26 39 2300 1 75 25 2 3 3/4 1/2 5H 6,7 2,9 13,8 1150 2000 58 26 7,8 3,1 14,7 1340 2000 56 26 39 2300 1 75 25 2 3 3/4 1/2

Scroll

Dimensions (mm)

IDROBLOC Height Width Depth Weight

A B C Kg

3 990 450 450 79

3H 990 450 450 80

5 1063 606 563 116

5H 1063 606 563 119 Cod.: SIDBUY.04 / 0709

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

241

IDROBLOC C
R407C

Air cooled chiller with radial fan With capacity from 3.5 up to 8.2 kW

IDROBLOC C is a low-consumption water chiller assembly designed for outdoor installation, sized to provide a water flow sufficient to run a relatively high number of terminal units. The thermal head of water to the evaporator can be contained to 2.5C; in practical terms, this means that the system can run fancoils in all rooms, though only operating the ones located in rooms that are occupied. The user can select which of the fancoils installed are to be activated, simply by turning individual units on or off, without ever having to adjust the water distribution circuit. It is possible to canalise the air delivery outwards by removing the grille for installation with free delivery. IDROBLOC C must be floor-mounted and has similar dimensions to those of a normal boiler for outside installation. IDROBLOC C is especially suitable for domestic use in new or renovated buildings.

Features
Unit for roof-hanging installation All versions are supplied for use with R407C Cooling only version Compact dimensions Centrifugal fan with vertical air delivery for possible ducted installation Evaporator dimensioned for working with t = 2.5 C Antifreeze electric heater for the plate heat exchanger (as standard) Antifreeze electric heater for the storage tank (RA accessory) Adjustment and control fully electronic with microprocessor card Pre-arrangement for coupling with boiler, with immediate seasonal switching Hydraulic circuit complete with pump, expansion tank, storage tank, water filter, flow switch and safety valve Possibility of powering the fan coils of all the environments, keeping in operation only those relative to rooms that are occupied Electric power used within the standard domestic availability limits Extreme simplicity of installation Metallic protective cabinet with rustproof polyester paint Color RAL 9002

Accessories
PR3: Simplified remote panel. Allows basic PRD1 : Smart remote panel. Repeats at a RA: Antifreeze electric heater for the storage machine checks to be carried out (turning on distance the functions of the panel on the tank. It must be factory-mounted. and off, signalling of alarms and season chanmachine. Can be made remote with shielded SDP: Electronic card for using PR3 accessory geover). Can be made remote with shielded cable up to 150 m. up to a distance of 150 m. cable up to 30 m. VT7: Anti-vibration mounts.
IDROBLOC 3C - 5C - 8C PR3 Compatibility of accessories PRD1 RA SDP VT 7

Installation
IDROBLOC C is quick and simple to install: simply position the unit, then make all water and electrical connections. The unit can be connected to any type of heating assembly: autonomous or centralised boiler, or district (remote) heating systems.

No duct air delivery

Ducted air delivery

242

Technical data
IDROBLOC Cooling capacity Total input power* Input current* Evaporator water flow rate Effective pressure e Sound pressure Total air flow rate (duct 900 mm)** Effective static pressure Compressors Peak current (compressor) Storage tank capacity Expansion tank capacity Pump speed Water connections (female Gas) kW kW A l/h (nominal) kPa (max.) dB (A) n. type A l l n. (installation) (heating)
3C 3.5 1.74 8.2 602 66 41 1150 20 1 Rotary 33.5 17 2 3 3/4 F Gas 1/2 F Gas 5C 6.8 3.25 14.8 1170 58 42 2500 50 1 Scroll 75 17 2 3 3/4 F Gas 1/2 F Gas 8C 8.2 3.85 19 1410 52 45 3000 50 1 Scroll 103 17 2 3 3/4 F Gas 1/2 F Gas

Power supply = 230V ~ 50Hz. Performance values refer to the following conditions: Sound pressure measured in free field conditions at distance of 10 m and direction factor = 2. Cooling: - water outlet temperature 7 C; - ambient air temperature 35 C; - t = 5 C. * = including circulator pump power consumption ** = with 900 mm channel without protection grille

Dimensions (mm)

IDROBLOC Height Width Depth Weight

A B C Kg

3C 1118 606 572 110

5C 1118 606 572 128

8C 1145 710 590 144

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

243

Cod.: SIDBCUY.00 / 0709

Venice
R407C

Water-cooled reversible heat pumps units With capacities from 6,9 up to 9,7 kW

Aermec participates in the EUROVENT Program LCP / W / P / C The products of interest can be found on the website www.eurovent-certification.com

Features
Available in 3 sizes Versions: Venice: cooling only Venice H: heat pump Cycle reversal on refrigerant circuit All versions are equipped with circulation pump, water tank, water filter and safety valve Complies with EEC Safety Directive (CE) Compact size High efficiency scroll compressors Metallic protective cabinet with rustproof Differential pressure switch on the external polyester paint circuit standard on heat pumps Degree of protection IP 24 Fluxostat standard on installation circuit Modular microprocessor control system Straightforward intuitive control panel High efficiency plate type heat exchangers

Accessories
PR3 : Remote control panel with ON/OFF, ser, thereby maintaining the condensation the water flows through both branches of the operating mode selection (cooling / heating) temperature unchanged. circuit. and general alarm indication. VPH: Pressure switch valve with bypass sole- VT: Rubber anti-vibration mounts. VP: Pressure switch valve complete with connoid valve: during cooling mode operation VT M: Spring anti-vibration mounts. nections, piloted directly in relation to conthe bypass valve is closed so the water flows densation pressure; the valve modulates the exclusively through the circuit with the presvolume of water needed to cool the condensure switch. During heating mode operation

Compatibility of accessories Mod. Venice 20 20 H 25 25 H 30 30 H

PR 3

VP 14

VP 15

VPH 10

VPH 11

VT 7

VT M

244

Technical data
Mod. Venice Cooling capacity Total input power* Evaporator water flow rate Usefoul head system side circuit Condenser water consumption Condenser pressure drop Heating capacity Total input power* Condenser water flow rate Usefoul head system side circuit Condenser water consumption (10 C) Evaporator pressure drop ENERGY INDEX EER ESEER COP ELETTRICAL DATA Power supply Input current Input current Max. current (FLA) Peak current (LRA) SOUNDA DATA Sound power Sound pressure HYDRAULIC CONNECTION Hydraulic connection** Storage tank capacity Compressor kW kW l/h kPa l/h kPa kW kW l/h kPa l/h kPa W/W W/W W/W A A A A dB(A) dB(A) l type 20 6,92 1,95 1187 63 1485 18 3,56 4,59 10,18 15 61 56,5 48,0 1 23 Scroll 20H 6,92 1,92 1187 63 1485 9 7,77 2,59 1342 61 929 2 3,60 4,00 3,00 10,18 13,39 15 61 56,5 48,0 1 23 Scroll 25 8,23 2,22 1410 61 1758 13 3,70 4,58 25H 8,23 2,22 1410 61 1758 10 9,26 3,08 1600 59 1106 2 3,71 4,23 3,00 30 9,74 2,62 1668 59 2080 12 3,72 4,58 13,18 24 100 57,5 49,0 1 23 Scroll 30 H 9,74 2,62 1668 59 2080 11 10,85 3,57 1875 57 1300 2 3,72 4,24 3,04 13,81 18,31 24 100 57,5 49,0 1 23 Scroll

230V ~ 50Hz. 11,89 11,89 15,70 18 18 76 76 56,5 48,5 1 23 Scroll 57,0 48,5 1 23 Scroll

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011 * ** Cooling processed water temperature 7 C; water inlet temperature to condenser 30 C; Dt = 5 C. Heating processed water temperature 50 C; water inlet temperature to evaporator 10 C; Dt = 5 C. including circulator pump power consumption. male Gas connection. Sound power Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744) Power supply = 1~ 230V 50Hz.

Dimensions (mm)

Mod. Venice 20 25 - 30 Mod. Venice Peso [Kg]

mm mm Venice Venice H

M 130 130

N 40 40

O 20 20

P 118 118 20 100 103

Q 77 77

R 304 304 25 103 106

S 249 249

T 120 120 30 105 109

U 220 220

V 111 111

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

245

Cod.: SVNCUY.04 / 1302

Mod. Venice 20 25 - 30

mm mm

A 504 504

B 404 404

C 625 625

D 190 190

E 83 83

F 20 20

G 48 48

H 465,5 465,5

I 20 20

L 25 25

WRL

025/160
cooling only

Water-cooled chillers Cooling capacity from 6,58 to 43,40 kW

DISPLAY MODU_CONTROL

KSAE External air sensor ACCESSORY Aermec participates in the EUROVENT Programme: LCP / W / P / C The products of interest can be found on the website www.eurovent-certification.com

HIGH EFFICIENCIES OPTION FOR: DESUPERHEATER SUITABLE FOR GEOTHERMAL APPLICATIONS


Characteristics
WRL is the range of water cooled chillers operating with refrigerant R410A. They are internal units with hermetic scroll compressors that respond perfectly to the market requirements: small dimensions, ease of installation, low noise. High efficiency Aermec has designed these units to optimise heat pump operation, providing high performances and low energy consumption. Connections The electric and hydraulic connections are all located on the upper part of the unit facilitating installation and maintenance. This allows reduced plant room space and installation in the smallest space possible.

PR3 Simplified remote panel ACCESSORY

Silent The WRL units are distinguished for their silence Versions in operation. Careful soundproofing of the unit WRL- (standard without buffer tank) with suitable sound-absorbent material results in WRL-A (with buffer tank) low sound levels for all units. Technical features Dynamic set point Structure and base in hot dip galvanised sheet Using the latest generation of electronic controlsteel with epoxy paint finish (RAL 9002) ler and with an external air temperature sensor Generously sized plate heat exchangers

"KSAE" (accessory). the heat pump unit can vary Compressors with high performance and low the leaving water temperature based on climatic electrical input conditions, thus increasing the energy efficiency Differential pressure switch standard (on of the system. evaporator side) Conforms with Safety Directives (CE) and the Advantages standards regarding electromagnetic Using the latest innovative technology and focus compatibility on maximum quality gives the WRL series the The safety of the unit is provided by the door maximum energy efficiency, ease of installation, interlocked isolator and active protection of and most versatile application using renewable the main components energy sources. Latest generation of electronic controller Control circuit board (Modu control) Range "PR3" simplified remote panel (ACCESSORY) Available in 9 sizes. Compatible with the (VMF) system except for domestic hot water production. Models WRL (cooling only) WRL E (evaporating unit), ships with holding charge only.

246

Accessories
VT: Anti-vibration mounts: four anti-vibration mounts to be installed under the unit's steel base. KSAE: External air sensor. Temperature sensor with plastic enclosure. PR3: Simplified remote panel. Allows control of the basic unit functions and alarm notification. Remote mounted up to 150 m distance with a shielded cable. AERSET: The AERSET accessory allows the automatic compensation of the operating setpoint of the unit to which it is connected, based on a 0-10V MODBUS input signal. Mandatory accessory: AER485 or MODU485A MODU-485A: RS-485 interface for supervising systems with MODBUS protocol. AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: - AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; - AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; - AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; - AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem;

Accessory compatibility
WRL VT (version ) VT (version A) KSAE PR3 AERSET MODU-485A AERWEB300 025 9 15 030 9 15 040 9 15 050 9 15 070 9 15 080 9 15 100 15 15A 140 15 15A 160 15 15A

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 456 7 8 9 10 11 12 13 14 15 | | | | | | | | | | | Code | Field of use | Version | Geothermal side | Field | Power supply | | | pump kit | not used | Size Model Heat recovery System side Soft start pump kit CODE: WRL SIZE: 025 - 030 - 040 - 050 - 070 - 080 - 100 - 140 - 160 FIELD OF USE: - Standard with leaving water down to +4 C Y - Low temperature with leaving liquid down to -8 C MODEL: - Cooling only E - Evaporating unit (shipped with holding charge only) VERSION: - Standard A - With buffer tank HEAT RECOVERY: - Without heat recovery D - Desuperheater GEOTHERMAL SIDE PUMP KIT VERSION : - Without pump Geothermal applications B - 3 speed PUMP ON-OFF (UP TO MODEL WRL 080) Single speed three-phase STANDARD PUMP (WRL 100-140-160 MODELS) U - Single speed three-phase HIGH HEAD PUMP (WRL 100-140-160 MODELS) F - Pump with phase cut control (MODELS UP TO WRL 080) I - Inverter Pump (MODELS UP TO WRL 080) Applications with bore hole water V - 2-way modulating valve SYSTEM SIDE PUMP KIT: Standard version - Without pump P - 3 speed ON-OFF PUMP (UP TO MODEL WRL 080) Single speed three-phase STANDARD PUMP (WRL 100-140-160 MODELS) N - Single speed three-phase HIGH HEAD PUMP (WRL 100-140-160 MODELS) FIELD NOT USED SOFT-START: - Without Soft-start S - With Soft-start POWER SUPPLY: - 400V 3N~ 50Hz M - 230V ~ 50Hz (only for models WRL 025 - 030 - 040)

Configuration example: WRL050YS

247

Technical Data
WRL MODEL Cooling capacity Input power Input current Evaporator water flow rate Pressure drop (system side) Water consumption (geothermal side) Pressure drop (geothermal side) ENERGY INDEX E.E.R. ESEER COMPRESSOR N circuits/N compressors Capacity control EVAPORATOR Hydraulic connections Quantity CONDENSER Hydraulic connections Quantity BUFFER TANK Tank capacity EXPANSION VESSEL WRL with pump only WRL pump and buffer tank SOUND DATA Sound power Sound pressure WRL-A MODEL Cooling capacity Input power Input current Evaporator water flow rate Useful head system side "P" Water consumption (geothermal side) Useful head geothermal side "B" ENERGY INDEX E.E.R. 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 kW kW A l/h kPa l/h kPa 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 kW kW A l/h kPa l/h kPa 025 6,58 6,58 1,58 1,53 7,20 4,29 1138 1138 15,0 15,0 1391 1383 28,0 28,0 4,15 4,29 4,22 4,42 1/1 0 - 100 F / 1"/14 1 F / 1"/14 1 100 1/2 1/8 55,5 24,3 025 6,64 6,64 1,60 1,55 8,77 4,67 1138 1138 66 66 1391 1383 52 52 4,14 4,27 025 66 66 65 65 n.d. n.d. 52 52 n.d. 52 52 52 52 030 8,27 8,37 1,92 1,84 9,20 4,57 1432 1449 18,0 19,0 1739 1741 29,0 30,0 4,30 4,56 4,41 4,65 1/1 0 - 100 F / 1"/14 1 F / 1"/14 1 100 1/2 1/8 57,0 25,8 030 8,36 8,46 1,90 1,81 10,81 4,21 1432 1449 63 63 1739 1741 48 48 4,41 4,69 030 62 61 61 60 n.d. n.d. 48 48 n.d. 48 48 48 48 040 11,26 11,16 2,70 2,60 11,70 4,90 1951 1934 23,0 23,0 2380 2348 36,0 35,0 4,18 4,29 4,34 4,46 050 14,56 3,27 6,40 2520 23,0 3044 32,0 4,45 4,59 070 19,06 4,22 7,40 3299 27,0 3973 40,0 080 21,66 4,95 9,10 3752 32,0 4539 46,0 100 29,26 6,51 12,80 5061 27,0 6109 42,0 140 38,08 8,46 14,80 6591 36,0 7940 57,0 160 43,40 9,91 18,20 7514 41,0 9090 66,0

W/W W/W

% n n l n/l n/l dB(A) dB(A)

4,51 4,37 4,49 4,50 4,38 4,58 4,46 4,89 4,84 4,69 SCROLL 1/1 1/1 1/1 1/1 1/2 1/2 1/2 0 - 100 0 - 100 0 - 100 0 - 100 0 - 50 - 100 0 - 50 - 100 0 - 50 - 100 PLATES F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 1 1 1 1 1 1 1 PLATES F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 1 1 1 1 1 1 1 Only for units with buffer tank / buffer tank and pumps 100 100 100 100 150 150 150 1/2 1/8 57,5 26,3 040 11,39 11,29 2,60 2,52 13,36 6,56 1951 1933 53 53 2380 2348 37 38 4,37 4,49 040 53 53 52 52 n.d. n.d. 38 38 n.d. 38 38 38 38 1/2 1/8 59,0 27,7 050 14,73 3,18 9,21 2520 82 3044 68 4,63 050 80 75 n.d. n.d. 68 n.d. 68 88 1/2 1/8 60,0 28,7 070 19,27 4,06 10,37 3299 72 3973 53 4,74 070 71 63 n.d. n.d. 53 n.d. 53 80 1/2 1/8 60,5 29,2 080 21,90 4,75 12,16 3751 65 4539 43 4,61 080 63 53 n.d. n.d. 43 n.d. 43 73 1/8 1/8 62,0 30,6 100 29,95 6,40 15,49 5061 147 6110 116 4,68 100 146 130 236 220 116 203 n.d. n.d. 1/8 1/8 63,0 31,6 140 39,00 8,32 18,19 6591 164 7940 137 4,68 140 162 133 247 218 137 222 n.d. n.d. 1/8 1/8 63,5 32,1 160 44,41 9,71 21,82 7514 158 9090 125 4,57 160 155 118 240 203 125 210 n.d. n.d.

W/W

HYDRONIC KIT Useful head system side A A P P N B Useful head geothermal side U All F I 230V-1 400V-3N 230V-1 400V-3N 400V-3N 230V-1 400V-3 400V-3 230V-1 400V-3 230V-1 400V-3

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011 COOLING


Evaporator inlet temperature 12C Evaporator outlet temperature 7C Condenser inlet temperature 30C Condenser outlet temperature 35C

SOUND POWER: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

SOUND PRESSURE: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

248

Technical Data E
WRL-E Model Cooling capacity Input power Input current E.E.R. Evaporator flow rate Pressure drop evaporator side Cooling: 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 kW kW A 025E 6,2 6,3 1,7 1,7 8,3 3,4 3,56 3,70 1070 1080 13 13 030E 7,8 7,8 2,1 2,0 10,5 3,2 3,65 3,87 1340 1340 15 15 040E 10,4 10,4 2,9 2,8 12,8 5,4 3,63 3,75 1790 1790 20 20 050E 13,4 3,6 7,2 3,73 2300 18 070E 17,4 4,5 8,3 3,83 2980 21 080E 19,7 5,3 10,2 3,71 3390 24 100E 26,8 7,2 14,3 3,73 4600 21 140E 34,7 9,1 16,6 3,83 5970 28 160E 39,4 10,6 20,5 3,71 6770 31

l/h
kPa

Condensing temperature 45C Outlet water temperature 7C; t 5C

Dimensions (mm)

A A A

B C

WRL 025-040 WRL Height (A) Width (B) Depth (C) Weight WRL Weight WRLE 025 976 607 628 120 110 030 976 607 628 125 115 040 976 607 628 130 125

WRL 050-080 050 1126 607 798 150 150 070 1126 607 798 170 150 080 1126 607 798 180 150 100 1126 1157 798 260 245

WRL 100-160 140 1126 1157 798 270 250 160 1126 1157 798 280 250

mm mm mm kg kg

B C C

WRL-A Height (A) Width (B) Depth (C) Weight *

mm mm mm Kg

025 1.126 1.157 798 190

030 1.126 1.157 798 200

040 1.126 1.157 798 210

050 1.126 1.157 798 230

070 1.126 1.157 798 250

080 1.126 1.157 798 260

100 1.126 1.757 798 340

140 1.126 1.757 798 350

160 1.126 1.757 798 360

* Weight with two heat exchangers and buffer tank without pumps.

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma. 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

249

Code : SWRLUY.02 / 1201

WRL-A 025-080

WRL-A 100-160

WRL
reversible water- side

180/650

Water-cooled reversible chillers for the production of hot water up to 55 C Cooling capacity from 50 to 168 kW Heating capacity from 51 to 180 kW

R410A
Aermec participates in the EUROVENT Programme: LCP / W / P / C The products of interest can be found on the website www.eurovent-certification.com

PGD1 Simplified remote panel. ACCESSORY

HIGH EFFICIENCIES POSSIBILITY OF HAVING: PARTIAL HEAT RECOVERY PRODUCTION OF HOT WATER UP TO 55 C SUITABLE FOR GEOTHERMAL APPLICATIONS
Characteristics
WRL is the range of water cooled chillers operating with refrigerant R410A. They are internal units with hermetic scroll compressors that respond perfectly to the market requirements: small dimensions, ease of installation, low noise. Dynamic set point Using the latest generation of electronic controller and with an external air temperature sensor (accessory), the heat pump unit can vary the leaving water temperature based on climatic conditions, thus increasing the energy efficiency of the system. Compressors with high performance and low electrical input Flow switch as standard Conforms with Safety Directives (CE) and the standards regarding electromagnetic compatibility The safety of the unit is provided by the door interlocked isolator and active protection of the main components Externally mounted user interface with display of all operating parameters in 4 languages Latest generation of electronic controller User-friendly remote mounted control panel with alarm notification.

High efficiency Aermec has designed these units to optimise Advantages heat pump operation, providing high perfor- Using the latest innovative technology and focus mances and low energy consumption. on maximum quality gives the WRL series the maximum energy efficiency, ease of installation, Connections and most versatile application using renewable The electric and hydraulic connections are all energy sources. located on the upper part of the unit facilitating installation and maintenance. This Range allows reduced plant room space and installa- Available in 8 sizes: tion in the smallest space possible. Water-side reversible system Silent The WRL units are distinguished for their silence in operation. Careful soundproofing of the unit with suitable sound-absorbent material results in low sound levels for all units. Version WRL= Cooling only: reversible water-side Technical features Structure and base in hot dip galvanised sheet steel with epoxy paint finish (RAL 9002) Generously sized plate heat exchangers

250

Accessories
AER485P1: RS-485 interface for supervising systems with MODBUS protocol. VT: Anti-vibration mounts: four anti-vibration mounts to be installed under the unit's steel base. STA: Room temperature sensor, 230 Vac recess mounted kit containing the ambient sensor with display and control knob, able to control an ON-OFF valve or a zone pump. STH: Room temperature and humidity sensor, 230 Vac recess mounted kit containing the sensor with display and control knob, able to control an ON-OFF valve or a zone pump and dehumidifier enable. SSM: Sensor to be used together with the VMFCRP: WRL Zones Control can control up mixing valve in applications with radiant panto a maximum of 3 zones with the following els. Accessory to be requested together with modes: the VMFCRP zone accessory. - Zone 1: Controlled as standard with the lat S...I: System buffer tanks: available in sizes est generation electronic controller. The 200, 300, 400 and 500 litres (S200I, S300I, "SSM" clamp on sensor (accessory) is recomS400I and S500I). mended to control the flow temperature. PGD1: Simplified remote panel. Allows control - The control of the remaining Zone 2 and of basic unit functions and alarm notification. Zone 3 is possible using the VMFCRP + SSM Remote mounted up to 500 m away with accessories for each zone. TWISTED PAIR SCREENED cable and TCONN6J000. KSAE: External air sensor. Temperature sensor with plastic enclosure. Accessory compatibility
WRL AER485P1 VT STA STH SSM S...I (200-300-400-500) PGD1 KSAE VMFCRP 180 9 200 9 300 9 400 9 500 15 550 15 600 15 650 15

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 456 7 8 9 10 11 12 13 14 15 | | | | | | | | | | | Code | Field of use | Version | Pumps | Field | Power supply | | | (condenser side) | not used | Size Model Heat Pumps Soft start recovery (evaporator side)

CODE: WRL SIZE: 180 - 200 - 300 - 400 - 500 - 550 - 600 - 650 FIELD OF USE: - Standard with leaving water above +4C Y - Low temperature with leaving liquid down to -8C X - Electronic expansion valve with leaving liquid down to +4C (for different temperature contact us) MODEL: - Reversible water-side E - Evaporating unit (not available for heat pump versions) (shipped with holding charge only) VERSION: - Standard HEAT RECOVERY - Without heat recovery D - Desuperheater PUMPS (CONDENSER SIDE) - Without pump B - Low static pressure pump U - High static pressure pump F - Low static pressure inverter pump I - High static pressure inverter pump V - 2-way modulating valve

PUMPS (EVAPORATOR SIDE) - Without pump P - Low static pressure pump N - High static pressure pump FIELD NOT USED SOFT START - Without Soft Start S - Soft Start POWER SUPPLY - 400V-3N -50 Hz 5 - 500V-3-50Hz (only models WRL400-550-600-650)

251

Technical data
Modello WRL Cooling capacity (E) Input power (E) Input current Evaporator water flow rate Evaporator pressure drop Condenser water flow rate Condenser pressure drop Heating capacity Input power Input current Condenser water flow rate Condenser pressure drop Evaporator water flow rate Evaporator pressure drop Energy index E.E.R. (E) E.S.E.E.R. C.O.P. Compressor N circuits/N compressors Capacity control Evaporator Hydraulic connections Quantity Condenser Hydraulic connections Quantity Desuperheater (optional) Hydraulic connections Quantity Expansion vessel (versions with pumps) Expansion vessel (per circuit) Sound data Sound power Sound pressure 180 50 10,95 19,90 8559 27 10176 27 51 12,79 22,80 8808 20 6668 19 4,52 4,61 4,02 1/2 50/100 2 1 2 1 1 1 1/8 61.1 29.1 200 64 14,52 25,00 11094 43 13210 46 69 17,46 29,50 11858 37 8963 31 4,42 4,43 3,97 1/2 50/100 2 1 2 1 1 1 1/8 61.8 29.8 300 74 16,91 28,50 12838 46 15290 62 76 19,16 32,00 13031 44 9859 30 4,39 4,40 3,98 1/2 50/100 2 1 2 1 1 1 1/8 62.9 30.9 400 86 18,34 31,90 14838 60 17459 81 89 21,29 35,90 15201 61 11711 41 4,67 4,40 4,18 500 100 20,51 36,30 17205 30 20242 32 102 23,49 41,10 17494 24 13560 20 4,86 5,47 4,35 550 129 26,96 50,80 22320 49 26265 52 140 32,51 57,80 24030 44 18640 37 4,79 5,67 4,32 1/2 50/100 2 1 2 1 1 1 1/12 79.1 47.1 600 150 30,98 59,30 25872 53 30400 57 161 37,00 66,70 27518 47 21381 38 4,83 5,23 4,34 1/2 50/100 2 1 2 1 1 1 1/12 79.1 47.1 650 168 35,73 68,30 29126 67 34312 72 180 42,04 76,10 30791 59 23843 47 4,71 4,82 4,28 1/2 50/100 2 1 2 1 1 1 1/12 79.1 47.1

kW kW A l/h kPa l/h kPa kW kW A l/h kPa l/h kPa W/W W/W -

% n n n n/l dB(A) dB(A)

SCROLL 1/2 1/2 50/100 50/100 PIASTRE 2 2 1 1 PIASTRE 2 2 1 1 PIASTRE 1 1 1 1 1/8 1/12 71.1 39.1 67.6 35.6

WRL model Usefoul head system side Usefoul head geothermal side

P N B-F U-I

kPa kPa kPa kPa

180 133 208 130 205

200 112 188 103 180

300 104 181 80 212

400 83 161 132 185

500 104 184 170 222

550 102 232 149 212

600 86 213 127 186

650 123 182 94 148

(E) for the reversible water-side EUROVENT certies only cooling capacity (12-7C / 30-35C)

DATA DECLARED IN ACCORDANCE WITH


UNI EN14511: 2011

COOLING
Evaporator inlet temperature 12C Evaporator outlet temperature 7C Condenser inlet temperature 30C Condenser outlet temperature 35C

HEATING
Evaporator inlet temperature 10C Evaporator outlet temperature 5C Condenser inlet temperature 40C Condenser outlet temperature 45C

SOUND POWER Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

SOUND PRESSURE Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).

Technical data WRL-E


Model WRL-E Cooling capacity Input power Input current EER Evaporator water flow rate Evaporator pressure drop Discharge line Liquid line Cooling: kW kW A l/h kPa mm mm 180 46.0 12.4 22.9 3.7 7900 23 28 22 200 60.1 16.0 28.5 3.8 10340 39 28 22 300 69.6 18.5 32.4 3.8 11980 39 28 22 400 80.1 19.8 35.6 4.1 13770 56 28 22 500 90.6 23.1 41.8 3.9 15580 25 35 28 550 121.3 29.6 55.8 4.1 20860 42 35 28 600 140.2 34.1 64.8 4.1 24110 47 35 28 650 158.7 38.5 73.9 4.1 27300 57 35 28

Condensing temperature Outlet water temperature

45C 7C; t 5C

252

Dimensions (mm)

B C

WRL 180-400

WRL 500-650

WRL Model Height (A) Width (B) Depth (C) Weight empty WRL- Weight empty WRL-D Weight empty WRL-E

mm mm mm kg kg kg

180 1380 1320 845 375 383 346

200 1380 1320 845 375 383 346

300 1380 1320 845 381 389 351

400 1380 1320 845 388 396 358

500 1380 2060 845 518 528 460

550 1380 2060 845 594 604 536

600 1380 2060 845 670 681 615

650 1380 2060 845 715 726 660

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

253

Code : SWRL2UY.03 / 1302

WRL
heat pump

025/160

Water cooled reversible heat pumps for the production of hot water up to 60 C Cooling capacity from 6 to 40 kW Heating capacity from 8 to 48 kW
WRL

R410A

Aermec participates in the EUROVENT Programme: LCP / W / P / C The products of interest can be found on the website www.eurovent-certification.com

STA - STH ACCESSORIES

HIGH EFFICIENCY POSSIBILITY OF HAVING: TOTAL HEAT RECOVERY. PRODUCTION OF HOT WATER USE UP TO 60 C PRIORITY PRODUCTION OF DHW SUITABLE FOR GEOTHERMAL APPLICATIONS REVERSIBLE REFRIGERANT SIDE
Characteristics
WRL is the range of water cooled chillers operating with refrigerant R410A. They are internal units with hermetic scroll compressors that respond perfectly to the market requirements: small dimensions, ease of installation, low noise. High efficiency Aermec has designed these units to optimise heat pump operation, providing high performances and low energy consumption. Connections The electric and hydraulic connections are all located on the upper part of the unit facilitating installation and maintenance. This allows reduced plant room space and installation in the smallest space possible. Silent The WRL units are distinguished for their silence in operation. Careful soundproofing of the unit with suitable sound-absorbent material results in low sound levels for all units. Priority production of domestic hot water The unit guarantees the prioritised production of DHW both in summer and winter. The temperature of DHW produced depends on the type of combination between the WRL heat pump and associated DHW devices. The heat pump unit is shipped with a temperature sensor kit for the DHW tank. Dynamic set point Using the latest generation of electronic controller and with an external air temperature sensor (accessory). the heat pump unit can vary the leaving water temperature based on climatic conditions, thus increasing the energy efficiency of the system. Advantages Using the latest innovative technology and focus on maximum quality gives the WRL series the maximum energy efficiency, ease of installation, and most versatile application using renewable energy sources. Range Available in 9 sizes with refrigerant side reversing. Versions WRL H WRL HA

Simplified remote panel.


ACCESSORIES

PGD1

Technical features Structure and base in hot dip galvanised sheet steel with epoxy paint finish (RAL 9002) Generously sized plate heat exchangers Compressors with high performance and low electrical input Pressostat as standard One temperature sensor kit for the DHW tank Conforms with Safety Directives (CE) and the standards regarding electromagnetic compatibility. The safety of the unit is provided by the door interlocked isolator and active protection of the main components Externally mounted user interface with display of all operating parameters in 4 languages Latest generation of electronic controller User-friendly remote mounted control panel with alarm notification.

254

Accessories
AER485P1: RS-485 interface for supervising systems with MODBUS protocol. VT: Anti-vibration mounts: four anti-vibration mounts to be installed under the unit's steel base. STA: Room temperature sensor. 230 Vac recess mounted kit containing the ambient sensor with display and control knob, able to control an ON-OFF valve or a zone pump. STH: Room temperature and humidity sensor. 230 Vac recess mounted kit containing the sensor with display and control knob, able to control an ON-OFF valve or a zone pump and dehumidifier enable. SSM: Sensor to be used together with the mixing valve in applications with radiant panels. Accessory to be requested together with the VMFCRP zone accessory. S...I: System buffer tanks: available in sizes 200, 300, 400 and 500 litres (S200I, S300I, S400I and S500I). PGD1: Simplified remote panel. Allows control of basic unit functions and alarm notification. Remote mounted up to 500 m away with TWISTED PAIR SCREENED cable and TCONN6J000. KSAE: External air sensor. Temperature sensor Accessory compatibility 050 070 9 9 9 9 with plastic enclosure. VMFCRP: WRL Zones Control can control up to a maximum of 3 zones with the following modes: - Zone 1: Controlled as standard with the latest generation electronic controller. The "SSM" clamp on sensor (accessory) is recommended to control the flow temperature. - The unit is shipped with a temperature sensor kit for the DHW tank. - The control of the remaining Zone 2 and Zone 3 is possible using the VMFCRP + SSM accessories for each zone.

WRL AER485P1 VT (version H) VT (version HA) STA STH SSM S...I (200-300-400-500) PGD1 KSAE VMFCRP

025 9 9

030 9 9

040 9 9

080 9 9

100 15 15A

140 15 15A

160 15 15A

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 456 7 8 9 10 11 12 13 14 15 | | | | | | | | | | | Code | Field of use | Version | Geothermal side | Heat recovery | Power supply | | | pumps kit | pumps kit | Size Model Heat recovery System side Soft start pump kit CODE: WRL SIZE: 025 - 030 - 040 - 050 - 070 - 080 - 100 - 140 - 160 FIELD OF USE: X - Electronic thermostatic valve (AS PER STANDARD FOR ALL MODELS) WRL 025-030-040-050-070-080 models water produced up to -8C WRL 100-140-160 models water produced up to +4C (for lower temperatures please contact us). MODEL: H - Heat pump VERSION: - Standard A - With buffer tank HEAT RECOVERY: - Without heat recovery T - With total heat recovery FOR HEAT PUMP VERSIONS ONLY VERSION "/A" GEOTHERMAL SIDE PUMP KIT: - Without pump Geothermal applications B - 3-SPEED PUMP ON-OFF (UP TO MODEL WRL 080) Single speed three-phase STANDARD PUMP (WRL 100-140-160 MODELS) U - Single speed three-phase HIGH HEAD PUMP (WRL 100-140-160) F - Pump with phase cut control (MODELS UP TO WRL 080) I - Pump Inverter recommended for TOTAL HEAT RECOVERY VERSIONS (MODELS UP TO WRL 080) Applications with bore hole water V - 2-way modulating valve

SYSTEM SIDE PUMP KIT: Standard version - Without pump P - 3-speed PUMP ON-OFF (UP TO MODEL WRL 080) Single speed three-phase STANDARD PUMP (WRL 100-140-160 MODELS) N - Single speed three-phase HIGH HEAD PUMP (WRL 100-140-160 MODELS) Version A - Without pump P - 3-speed PUMP ON-OFF (UP TO MODEL WRL 080) Single speed three-phase STANDARD PUMP (WRL 100-140-160 MODELS) J - 3-speed HIGH HEAD PUMP ON-OFF (MODELS WRL 025-030-040) N - Single speed three-phase HIGH HEAD PUMP (MODELS WRL 050-070-080-100-140-160) HEAT RECOVERY PUMP KIT: - Without pump Q - Pump SOFT-START: - Without Soft-start S - With Soft-start POWER SUPPLY: - 400V 3N~ 50Hz M - 230V ~ 50Hz (only for size WRL 025 - 030 - 040) 4 - 230V~3~50Hz (only for size WRL 050-070-080-100-140-160)

255

Technical Data
WRL-H MODEL Cooling capacity Input power Input current Evaporator water flow rate Pressure drop (system side) Condenser water flow rate Pressure drop (geothermal side) Heating capacity Input power Input current Condenser water flow rate Pressure drop (system side) Condenser water flow rate Pressure drop (geothermal side) ELECTRICAL INDEX E.E.R. E.S.E.E.R. C.O.P. WRL-HA MODEL Cooling capacity Input power Input current Evaporator water flow rate Useful head system side "P" Condenser water flow rate Useful head geothermal side "B" Heating capacity Input power Input current Condenser water flow rate Pressure drop (system side) Evaporator water flow rate Pressure drop (geothermal side) ELECTRICAL INDEX E.E.R. C.O.P. HYDRONIC KIT Usefoul head system side Usefoul head geothermal side P N B U I 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3 230V-1 400V-3N 400V-3N 230V-1 400V-3N 400V-3N 230V-1 400V-3N kW kW A l/h kPa l/h kPa kW kW A l/h kPa l/h kPa W/W W/W W/W 025 6,28 6,28 1,75 1,65 8,5 4,2 1086 1086 13,0 13,0 1371 1354 22,0 21,4 7,94 7,93 2,10 2,09 10,5 4,9 1355 1354 20,4 20,0 1700 1700 34,0 32,3 3,58 3,81 3,97 4,23 3,78 3,80 025 6,34 6,33 1,79 1,69 10,07 5,77 1086 1085 67 68 1371 1353 52 53 7,57 7,55 2,11 2,11 12,16 6,46 1307 1304 62 62 967 963 66 66 3,54 3,75 3,59 3,58 67 69 n.d. 52 58 n.d. 62 67 030 7,87 8,09 1,99 1,91 10,8 3,8 1362 1400 15,0 15,8 1686 1708 22,0 22,6 10,00 9,53 2,60 2,43 13,1 4,9 1709 1628 22,0 20,0 2150 2064 37,4 33,6 3,95 4,24 4,42 4,66 3,85 3,92 030 7,95 8,18 1,99 1,90 12,40 5,40 1362 1400 65 64 1686 1708 50 49 9,68 9,13 2,56 2,43 14,79 6,48 1673 1577 57 60 1251 1178 63 65 3,99 4,30 3,79 3,76 65 64 n.d. 50 55 n.d. 60 65 040 10,26 10,37 2,55 2,42 13,5 5,8 1776 1795 20,0 20,4 2186 2183 30,0 30,0 12,68 12,56 3,35 3,14 16,6 6,7 2164 2127 29,0 28,0 2720 2746 46,5 46,5 4,02 4,28 4,37 4,64 3,79 4,00 040 10,37 10,48 2,48 2,35 15,14 7,44 1776 1795 57 57 2186 2183 44 44 12,12 11,94 3,24 3,01 18,23 8,32 2092 2061 49 50 1550 1559 61 61 4,17 4,45 3,73 3,96 57 57 n.d. 44 46 n.d. 54 56 050 13,71 3,18 7,2 2372 19 2886 29 16,47 4,13 8,5 2813 28,0 3589 43,3 4,31 4,65 3,99 050 13,87 3,12 9,97 2372 85 2886 72 15,73 4,02 11,13 2719 77 2051 93 4,44 3,92 85 n.d. 72 n.d. 87 070 17,66 4,42 9,0 3055 22 3770 36 21,03 5,32 10,7 3591 32,3 4569 49,6 3,99 4,23 3,95 070 17,86 4,29 11,93 3055 78 3770 59 19,98 5,11 13,45 3453 68 2594 88 4,17 3,91 78 n.d. 59 n.d. 78 080 20,16 5,19 10,2 3489 26 4326 41 24,19 6,23 12,2 4130 37,6 5232 58,8 3,89 4,10 3,88 080 20,38 5,01 13,22 3489 71 4326 49 23,09 5,95 15,04 3986 59 2982 83 4,07 3,88 71 n.d. 49 n.d. 71 100 27,43 6,35 13,3 4741 22 5771 37 32,93 8,22 16,1 5628 35,3 7178 52,3 4,32 5,28 4,01 100 28,09 6,25 15,94 4742 154 5771 126 31,09 8,00 18,44 5438 138 4102 166 4,49 3,89 154 243 126 213 n.d. 140 35,27 8,80 16,7 6100 29 7525 48 41,90 10,55 20,7 7157 43,1 9110 62,0 4,01 4,84 3,97 140 36,12 8,74 19,99 6100 170 7525 144 39,40 10,33 23,41 6894 160 5185 176 4,14 3,81 170 255 147 233 n.d. 160 40,28 10,32 19,1 6968 33 8636 56 48,17 12,41 23,9 8224 51,0 10403 73,0 3,90 4,56 3,88 160 41,22 10,19 22,60 6968 164 8636 133 45,47 12,09 26,71 7947 152 5940 171 4,04 3,76 164 249 136 222 n.d.

kW kW

A l/h
kPa l/h kPa kW kW A

l/h
kPa l/h kPa

W/W W/W
kPa kPa kPa kPa kPa kPa kPa kPa

PERFORMANCE IN ACCORDANCE WITH UNI EN14511: 2011 ATTENTION: Please refer to the data of the HA version for units with buffer tank and pumps. The technical data includes the input power of the standard geothermal and system side pumps.

COOLING Evaporator inlet temperature 12C Evaporator outlet temperature 7C Condenser inlet temperature 30C Condenser outlet temperature 35C

HEATING Evaporator inlet temperature 10C Evaporator outlet temperature 5C Condenser inlet temperature 40C Condenser outlet temperature 45C

256

WRLH- /A Model Compressor N circuits / N compressors Capacity control Evaporator Hydraulic connections Quantity Condenser Hydraulic connections Quantity Buffer tank Buffer tank capacity Expansion vessel WRLH with pump WRLH pump and buffer tank Sound data Sound power Sound pressure

025 n/n % n n l n/l n/l dB(A) dB(A) 1/1 0 - 100 F / 1"/14 1 F / 1"/14 1 100 1/2 1/8 55,5 24,3

030 1/1 0 - 100 F / 1"/14 1 F / 1"/14 1 100 1/2 1/8 57,0 25,8

070 080 100 SCROLL 1/1 1/1 1/1 1/1 1/2 0 - 100 0 - 100 0 - 100 0 - 100 0 - 50 - 100 PLATE F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 1 1 1 1 1 PLATE F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 F / 1"/14 1 1 1 1 1 Only for units with buffer tank / buffer tank-pump 100 100 100 100 150 1/2 1/8 57,5 26,3 1/2 1/8 59,0 27,7 1/2 1/8 60,0 28,7 1/2 1/8 60,5 29,2 1/8 1/8 62,0 30,6

040

050

140 1/2 0 - 50 - 100 F / 1"/14 1 F / 1"/14 1 150 1/8 1/8 63,0 31,6

160 1/2 0 - 50 - 100 F / 1"/14 1 F / 1"/14 1 150 1/8 1/8 63,5 32,1

SOUND POWER Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

SOUND PRESSURE Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).

Dimensions (mm)

A A A

B C

WRL 025-040 WRL Height (A) Width (B) Depth (C) Weight 025H 976 607 628 120 030H 976 607 628 125

WRL 050-080 040H 976 607 628 130 050H 1.126 607 798 150 070H 1.126 607 798 170 080H 1.126 607 798 180

WRL 100-160 100H 1.126 1.157 798 260 140H 1.126 1.157 798 270 160H 1.126 1.157 798 280

mm mm mm kg

B C C

WRL 025-080 WRL Height (A) Width (B) Depth (C) Weight * 025HA 1126 1157 798 190 030HA 1126 1157 798 200 040HA 1126 1157 798 210 050HA 1126 1157 798 230

WRL 100-160 070HA 1126 1157 798 250 080HA 1126 1157 798 260 100HA 1126 1757 798 340 140HA 1126 1757 798 350 160HA 1126 1757 798 360

mm mm mm Kg

* Weight with two heat exchangers and buffer tank without pumps.
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma. 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

257

Cod.: SWRLHUY.07 / 1302

WRL

180/650

Water cooled reversible heat pumps for the production of hot water up to 55 C Cooling capacity from 45 to 157 kW Heating capacity from 53 to 184 kW

reversible refrigerant c i r c u i t

Aermec participates in the EUROVENT Programme: LCP / W / P / C The products of interest can be found on the website www.eurovent-certification.com

PGD1 Simplified remote panel. ACCESSORY

HIGH EFFICIENCIES POSSIBILITY OF HAVING: PARTIAL HEAT RECOVERY PRODUCTION OF HOT WATER UP TO 55 C SUITABLE FOR GEOTHERMAL APPLICATIONS
Characteristics
WRL is the range of water cooled chillers operating with refrigerant R410A. They are internal units with hermetic scroll compressors that respond perfectly to the market requirements: small dimensions, ease of installation, low noise. High efficiency Aermec has designed these units to optimise heat pump operation, providing high performances and low energy consumption. Connections The electric and hydraulic connections are all located on the upper part of the unit facilitating installation and maintenance. This allows reduced plant room space and installation in the smallest space possible. Silent The WRL units are distinguished for their silence in operation. Careful soundproofing of the unit with suitable sound-absorbent material results in low sound levels for all units. Dynamic set point Using the latest generation of electronic controller and with an external air temperature sensor (accessory), the heat pump unit can vary the leaving water temperature based on climatic conditions, thus increasing the energy efficiency of the system. Advantages Using the latest innovative technology and focus on maximum quality gives the WRL series the maximum energy efficiency, ease of installation, and most versatile application using renewable energy sources. Range Available in 8 sizes: Reversible refrigerant side Version WRLH= Heat pump Technical features Structure and base in hot dip galvanised sheet steel with epoxy paint finish (RAL 9002) Generously sized plate heat exchangers Compressors with high performance and low electrical input Flow switch as standard Conforms with Safety Directives (CE) and the standards regarding electromagnetic compatibility The safety of the unit is provided by the door interlocked isolator and active protection of the main components Externally mounted user interface with display of all operating parameters in 4 languages Latest generation of electronic controller User-friendly remote mounted control panel with alarm notification.

258

Accessories
AER485P1: RS-485 interface for supervising systems with MODBUS protocol. VT: Anti-vibration mounts: four anti-vibration mounts to be installed under the unit's steel base. STA: Room temperature sensor, 230 Vac recess mounted kit containing the ambient sensor with display and control knob, able to control an ON-OFF valve or a zone pump. STH: Room temperature and humidity sensor, 230 Vac recess mounted kit containing the sensor with display and control knob, able to control an ON-OFF valve or a zone pump and dehumidifier enable. SSM: Sensor to be used together with the mixing valve in applications with radiant panels. Accessory to be requested together with the VMFCRP zone accessory. S...I: System buffer tanks: available in sizes 200, 300, 400 and 500 litres (S200I, S300I, S400I and S500I). PGD1: Simplified remote panel. Allows control of basic unit functions and alarm notification. Remote mounted up to 500 m away with TWISTED PAIR SCREENED cable and TCONN6J000. KSAE: External air sensor. Temperature sensor with plastic enclosure. VMFCRP: WRL Zones Control can control up to a maximum of 3 zones with the following modes: - Zone 1: Controlled as standard with the latest generation electronic controller. The "SSM" clamp on sensor (accessory) is recommended to control the flow temperature. - The control of the remaining Zone 2 and Zone 3 is possible using the VMFCRP + SSM accessories for each zone.

ACCESSORY COMPATIBILITY
WRLH AER485P1 VT STA STH SSM S...I (200-300-400-500) PGD1 KSAE VMFCRP 180 9 200 9 300 9 400 9 500 15 550 15 600 15 650 15

VMFCRP

Unit configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.

Configuration fields:
1 2 3 456 7 8 9 10 11 12 13 14 15 | | | | | | | | | | | Code | Field of use | Version | Pumps | Field | Power supply | | | (geothermal side) | not used | Size Model Heat Pumps Soft start recovery (system side) CODE: WRL SIZE: 180 - 200 - 300 - 400 - 500 - 550 - 600 - 650 FIELD OF USE: - Standard with leaving water above +4 C Y - Low temperature with leaving liquid down to -8 C X - Electronic expansion valve with leaving liquid down to +4C (for different temperature contact us) MODEL: H - Reversible refrigerant circuit VERSION: - Standard HEAT RECOVERY - Without heat recovery D - Desuperheater PUMPS (GEOTHERMAL SIDE) - Without pump B - Low static pressure pump U - High static pressure pump F - Low static pressure inverter pump I - High static pressure inverter pump V - 2-way modulating valve PUMPS (SYSTEM SIDE) - Without pump P - Low static pressure pump N - High static pressure pump FIELD NOT USED SOFT START - Without Soft Start S - Soft Start POWER SUPPLY - 400V-3N -50 Hz 5 - 500V-3-50Hz (only models WRL400-550-600-650)

259

Technical Data
WRL-H model Cooling capacity Kw Input power Kw Input current A Evaporator water flow rate l/h Evaporator pressure drop kPa Condenser water flow rate l/h Condenser pressure drop kPa Heating capacity Kw Input power Kw Input current A Condenser water flow rate l/h Condenser pressure drop kPa Evaporator water flow rate l/h Evaporator pressure drop kPa Energy index E.E.R. W/W E.S.E.E.R. W/W C.O.P. W/W Compressor N circuits/N compressors Capacity control % Geothermal side heat exchanger Hydraulic connections Quantity n System side heat exchanger Hydraulic connections Quantity n Desuperheater (optional) Hydraulic connections Quantity n Expansion vessel (versions with pumps) Expansion vessel (per circuit) n/l Sound data Sound power Sound pressure dB(A) dB(A) 180 45 10,96 20 7740 20 9365 32 53 13,04 23 9113 30 12009 49 4,09 4,72 4,08 1/2 50/100 2 1 2 1 1 1 1/8 61.1 29.1 200 59 14,83 25 10286 37 12453 55 71 17,76 29 12175 52 16042 89 4,01 4,53 4,01 1/2 50/100 2 1 2 1 1 1 1/8 61.8 29.8 300 65 16,47 28 11180 37 13595 53 77 19,11 31 13154 49 17343 92 3,93 4,58 4,03 1/2 50/100 2 1 2 1 1 1 1/8 62.9 30.9 400 79 18,68 32 13726 55 16419 76 93 22,57 37 15913 72 21229 132 4,24 4,54 4,13 SCROLL 1/2 50/100 2 1 2 1 1 1 1/8 71.1 39.1 1/2 50/100 PLATES 2 1 PLATES 2 1 PLATES 1 1 1/12 67.6 35.6 1/2 50/100 2 1 2 1 1 1 1/12 79.1 47.1 1/2 50/100 2 1 2 1 1 1 1/12 79.1 47.1 1/2 50/100 2 1 2 1 1 1 1/12 79.1 47.1 500 93 20,23 36 16030 25 19034 35 107 23,98 41 18298 32 24645 61 4,59 5,62 4,46 550 120 27,69 52 20709 40 24780 58 144 33,06 57 24705 58 33289 107 4,33 5,43 4,37 600 140 31,44 60 24166 40 28795 58 165 37,16 65 28247 56 38175 101 4,45 5,42 4,44 650 157 35,97 69 27142 50 32405 73 184 42,60 75 31523 70 42437 125 4,36 5,00 4,33

WRL-H model Usefoul head system side Usefoul head geothermal side

P N B-F U-I

kPa kPa kPa kPa

180 141 217 126 202

200 120 195 96 173

300 117 193 95 226

400 92 169 140 194

500 114 193 172 225

550 116 247 148 213

600 105 233 133 193

650 147 210 102 158

PERFORMANCE IN ACCORDANCE WITH UNI EN14511: 2011

COOLING Evaporator inlet temperature 12C Evaporator outlet temperature 7C Condenser inlet temperature 30C Condenser outlet temperature 35C

HEATING Evaporator inlet temperature 10C Evaporator outlet temperature 5C Condenser inlet temperature 40C Condenser outlet temperature 45C

SOUND POWER Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification.

SOUND PRESSURE Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744).

260

Dimensions (mm)

B C

WRLH 180-400

WRLH 500-650

WRLH Model Height (A) Width (B) Depth (C) Weight empty

mm mm mm kg

180 1380 1320 845 370

200 1380 1320 845 370

300 1380 1320 845 381

400 1380 1320 845 388

500 1380 2060 845 522

550 1380 2060 845 598

600 1380 2060 845 708

650 1380 2060 845 753

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

261

Code : SWRLH2UY.03 / 1301

VXT
R410A

Water cooled GEOTHERMAL reversible heat pump Heating, cooling and domestic hot water

Aermec participates in the EUROVENT Program: LCP / W / P / C The products of interest can be found on the website www.eurovent-certication.com

DOMESTIC HOT WATER: DHW TEMPERATURE UP TO 55 C 180 LITRE DHW STORAGE TANK SUITABLE FOR GEOTHERMAL APPLICATION Features
The VXT heat pump provides winter heating and summer air conditioning of the home. VXT also produces domestic hot water: DHW temperature up to 55 C Small indoor units making them very easy to install in a kitchen for example or even inside a cabinet like the type used for a fridge. The careful choice of the sound-absorbent materials makes the unit particularly quiet. Main features: Refrigerant circuit Refrigerant R410A Refrigerant side reversing Scroll compressors - High level of reliability - High efficiency to guarantee the production of water up to 55 C, also suitable for traditional radiators. Externally isolated plate heat exchangers to decrease heat loss and optimised to obtain high efficiency Dual-flow electronic expansion valve High and low pressure transducers and pressure switches

DESIGNED FOR SUPPLEMENTARY SOLAR PANEL INTEGRATION

Hydraulic circuit The unit is equipped as standard with all components needed for correct and safe operation System side: following included 3-speed circulating pump expansion vessel safety valve brazed plate heat exchanger DHW side: following included 180 litre storage tank with coil for the production of hot water using the heat of condensation plate heat exchanger for the instantaneous production of hot water 2 supplementary electrical heaters tank with connections for solar panels water filter mounted at the inlet of the plate heat exchanger mixing valve with manual adjustment Options Supplementary electric heaters Geothermal application: it is possible to have

ON-OFF pump Pump with phase cut control Inverter Pump Bore hole water sheet application: possible to have 2-way modulating valve Electronic controller The microprocessor supplied provides control of: - hydraulic pumps on the system and geothermal circuit sides - radiant plant temperature and humidity sensor - DHW boiler temperature probe - external air temperature sensor for the compensation of the system water set point - system mixing valve - optional supplementary solar control kit - control of up to two ambient zones with digital inputs.

262

Accessories
KST KFC PGD0 VT Solar heat kit. Free-cooling kit Remote control panel Group of 4 anti-vibration mounts ACCESSORY COMPATIBILITY VXT 08 VXT 10 08 10

KST KFC PGD0 VT 15

VXT 06 06

VXT 14 14

VXT 16 16

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most particular of system requirements. Configuration fields: 123 | | Code Code: VXT Size: 06 - 08 - 10 - 14 - 16 Applications: P - ON-OFF pump F - Pump with phase cut control X - Inverter Pump V - With 2-way modulating valve FOR GEOTHERMAL APPLICATIONS FOR GEOTHERMAL APPLICATIONS FOR GEOTHERMAL APPLICATIONS FOR APPLICATIONS WITH BORE HOLE WATER 45 | | | Size 6 | | Applications 7 | | | Electric heaters 8 | | Soft start 9 | | | Power supply

Electric heaters: - Standard (without DHW supplementary heaters) R - With DHW supplementary heaters Soft-start: (standard for the 230V ~ 50Hz versions) - Standard (without soft-start) S - With Soft-start kit 400V 3N~ 50Hz Power supply: M - 230V ~ 50Hz T - 400V 3N~ 50Hz

VXT KST

KFC

263

Technical Data
VXT HEATING MODE OPERATION 30/35 C - 10/5 C (Under floor system) 230V Heating capacity kW 400V 230V Total power input kW 400V 230V COP 400V 230V Current input A 400V 230V Condenser water flow rate l/h 400V 230V Evaporator water flow rate l/h 400V HEATING MODE OPERATION 40/45 C - 10/5 C (Fan coils) 230V Heating capacity kW 400V 230V Total power input kW 400V 230V COP 400V 230V Current input A 400V 230V Condenser water flow rate l/h 400V 230V Evaporator water flow rate l/h 400V COOLING MODE OPERATION 23/18 C - 30/35 C (Under floor system)

06
7.6 7.6 1.6 1.6 4,75 4,75 8 3.6 1310 1310 1050 1050 7.52 7.52 2.21 2.07 3,40 3,63 10.7 4.2 1290 1290 930 960

08
9.7 9.9 2.0 1.9 4,85 5,21 10.6 3.4 1670 1700 1350 1390 9.28 9.47 2.59 2.46 3,58 3,85 13.4 4.6 1600 1630 1170 1230

10
12.3 12.3 2.6 2.4 4,73 5,13 13.3 5.3 2120 2110 1700 1720 12.18 11.76 3.25 3.00 3,75 3,92 16.4 6.3 2090 2020 1560 1530

14
16.4 3.2 5,13 7.3 2820 2300 16.24 4.00 4,06 8.9 2790 2140

16
18.6 3.6 5,17 7.5 3200 2610 17.79 4.50 3,95 8.8 3060 2320

230V 400V 230V Total power input kW 400V 230V EER 400V 230V Current input kW 400V 230V Evaporator water flow rate l/h 400V 230V Condenser water flow rate l/h 400V COOLING MODE OPERATION 12/7 C - 30/35 C (Fan coils) 230V Cooling capacity kW 400V 230V Total power input kW 400V 230V EER 400V 230V Current input kW 400V 230V Evaporator water flow rate l/h 400V 230V Condenser water flow rate l/h 400V 230V Maximum current input A 400V Starting current with Soft-start A 230V Starting current A 400V e Sound pressure dB(A) Cooling capacity kW

8.7 8.5 1.7 1.6 5,12 5,31 8.2 3.7 1500 1450 1770 1720 6.21 6.39 1.71 1.61 3,63 3,97 8 3.6 1070 1100 1350 1360 16.0 5.5 29.5 32.0 35.0

10.5 10.1 2.0 1.9 5,25 5,32 10.7 3.6 1810 1740 2140 2060 7.89 8.21 2.01 1.92 3,93 4,28 10.6 3.4 1360 1410 1690 1730 19.0 6.0 37.5 35.0 37.0

13.6 13.7 2.5 2.4 5,44 5,71 13.5 5.4 2340 2360 2750 2760 10.23 10.3 2.51 2.41 4,08 4,27 13.3 5.3 1760 1770 2170 2170 23.0 8.0 45.0 48.0 37.0

17.8 3.3 5,39 7.5 3070 3600 13.38 3.32 4,03 7.3 2300 2840 10.0 64.0 39.0

20.3 3.5 5,80 7.5 3500 4080 15.26 3.52 4,34 7.5 2620 3200 11.8 64.0 41.5

Performance in accordance with EN 14551:2004. Sound pressure Environment volume of 80 m3, reverberation time 0.5 s, distance 3 metres and directivity factor 4.

264

Dimensions (mm)

VXT. Height Width Depth Weight mm mm mm kg

06 2000 560 560 254

08 2000 560 560 256

10 2000 560 560 268

14 2000 560 560 283

16 2000 560 560 291

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

265

Code.: SVXTUY.03 / 1301

NXW
0500/1400

Water cooled internal chiller and heat pump units with scroll compressors Cooling capacity from 106 kW to 385 kW Heating capacity from 119 kW to 419 kW

Aermec adheres to the EUROVENT Certification Programme: LCP/W/P/C - LCP/W/P/R The products concerned appear in the EUROVENT Certified Products Guide.

HIGH EFFICIENCY VERSION CLASS "A" EUROVENT HEAT PUMP WITH REFRIGERANT SIDE REVERSING FOR GEOTHERMAL APPLICATIONS OPTION OF 1 OR 2 PUMPS ON BOTH EVAPORATOR AND CONDENSER SIDE PRODUCTION OF HOT WATER UP TO 55 C

Characteristics
NXW is the range of water cooled heat pumps that operate with refrigerant R410a. They are internal units with hermetic scroll compressors that respond perfectly to the market requirements: small dimensions, ease of installation, low noise. Maximum energy efficiency For years Aermec has been attentive to the energy efficiency issue, and has now designed the NXW units with the aim of ensuring high efficiency levels with both full and partial loads. The results are an EER level of 5.05 and COP at 4.45 (Class A Eurovent) Models available NXW: water side reversible heat pump NXWH: refrigerant side reversible heat pump All models are available in low noise version The machine can be supplied with a hydronic module for both the evaporator and the condenser side; each module includes a water filter fitted, low or high head pump, flow switch, and a 25 litre system side expansion tank, thereby optimising space, time and installation costs. It is possible to request a standby low or high head pump. Advanced controls The NXW controller provides several functions: - Two chiller units in parallel (run/standby) - Programmed pump rotation - Inverter condenser pump control to manage the condensing pressure - Programmable time-clock - Automatic water set point compensation - Data logging Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002) High efficiency plate heat exchangers Compressors with high performance and low electrical input High and low pressure transducers as standard Conforms with Safety Directives (CE) and the standards regarding electromagnetic compatibility The safety of the unit is provided by the door interlocked isolator and active protection of the main components Externally mounted user interface with display of all operating parameters in 4 languages User-friendly remote mounted control panel with alarm notification.

Accessories
AER485P1: RS-485 interface for supervision

integrated GPRS modem; at time of order and is available factory fitted systems with MODBUS protocol. AERWEB300-18G: Web server to monitor and only. AERWEB300: Accessory AERWEB allows remote remote control max. 18 units in RS485 network AVX: spring anti-vibration mounts. control of a chiller through a common PC and an with integrated GPRS modem; DRE: Soft starter (current reduction of about ethernet connection over a common browser; 4 PGD1: In addition to the unit mounted con30% for single circuit units, 26% for two cirversions available: troller on the NXW unit a remote mounted cuit units, 22% for three circuit units). Only AERWEB300-6: Web server to monitor and remote PGD1 panel can be supplied providing the available for 400V-3-phase power supply. control max. 6 units in RS485 network; same functions (keyboard controls and disFactory fitted only. AERWEB300-18: Web server to monitor and remote play). control max. 18 units in RS485 network; RIF: Power factor correction. Connected in AERWEB300-6G: Web server to monitor and remoparallel to the motor allowing about 10% te control max. 6 units in RS485 network with reduction of input current. Must be requested

266

Accessory Compatibility
NXW AER485P1 ALL AERWEB300 ALL REMOTE CONTROL PANEL PGD1 ALL AVX + 1 PUMP + 2 PUMPS + 3 PUMPS + 4 PUMPS H H + 1 PUMP H + 2 PUMPS H+ 3 PUMPS H + 4 PUMPS L L+ 1 PUMP L+ 2 PUMPS L + 3 PUMPS L + 4 PUMPS HL HL+ 1 PUMP HL+ 2 PUMPS HL + 3 PUMPS HL + 4 PUMPS E E + 1 PUMP E + 2 PUMPS E + 3 PUMPS E + 4 PUMPS LE L E + 1 PUMP L E + 2 PUMPS L E + 3 PUMPS L E + 4 PUMPS T LT RIF ALL DRE ALL 0500 319 320 320 320 309 319 320 320 309 309 309 321 311 311 312 309 311 311 312 312 319 320 320 320 309 309 321 311 311 312 303 312 RIF98 DRE501 0550 319 320 320 320 309 319 320 320 309 309 309 321 311 311 312 309 311 311 312 312 319 320 320 320 309 309 321 311 311 312 303 312 RIF98 DRE551 0600 301 320 309 309 310 301 320 303 303 312 310 311 31 312 312 310 311 312 312 312 301 320 309 309 310 310 311 31 312 312 310 651 RIF95 DRE601 0650 301 320 309 309 310 301 309 309 311 312 303 311 311 312 310 303 311 313 313 313 301 320 309 309 310 303 311 311 312 310 310 651 RIF95 DRE651 0700 301 320 309 309 310 302 309 311 312 312 303 651 651 651 651 304 651 651 651 651 301 320 309 309 310 303 651 651 651 651 310 652 RIF95 DRE701 0750 303 312 312 312 312 310 651 651 651 651 310 651 651 651 651 314 652 652 652 652 303 312 312 312 312 310 651 651 651 651 314 652 RIF95 DRE751 0800 310 651 651 651 651 310 651 651 651 651 314 652 652 652 652 314 665 665 665 665 310 651 651 651 651 314 652 652 652 652 652 652 RIF95 DRE801 0900 314 665 665 665 665 314 665 665 665 665 314 653 653 653 653 315 653 653 653 653 314 665 665 665 665 314 653 653 653 653 315 323 RIF96 DRE901 1000 316 653 653 653 653 316 654 654 654 654 315 654 654 654 654 317 659 659 659 659 316 653 653 653 653 315 654 654 654 654 322 324 RIF97 DRE1001 1250 316 654 654 654 654 315 654 654 654 654 315 659 659 659 659 317 659 659 659 659 316 654 654 654 654 315 659 659 659 659 322 324 RIF97 DRE1251 1400 315 654 654 654 654 317 654 654 654 654 317 659 659 659 659 318 659 659 659 659 315 654 654 654 654 317 659 659 659 659 322 324 RIF97 DRE1401

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements.
Configuratore campi 123 | 4567 | | | 8 | Field of use 9 | | | 10 | 11 | | | Evaporator 12 | Heat recovery 13 | | | Power supply 14*** | 15*** | | | Pumps Condenser

Code Size
Sigla: NXW Grandezza:

Version

Pumps Evaporator

Model

Power supply:
- 400V 3~ 50Hz with circuit breakers 4 - 220V 3~ 50Hz with circuit breakers* 5 - 500V 3 50Hz with circuit breakers**

0500, 0550, 0600, 0650, 0700, 0750, 0800, 0900, 1000, 1250, 1400 Campo d'impiego: - Thermostatic expansion valve with leaving water above +4 C Y - Thermostatic expansion valve for low leaving liquid down to -8 C X - Electronic thermostatic valve, max. temp. of water produced: +4C

(for lower temperatures please contact us) Model: - Heat pump with water side reversing
H - pompa di calore inversione ciclo lato gas Versione: - Standard L - Low Noise Evaporator: - Standard E - Evaporating unit (shipped with holding charge only) Heat recovery: - Without heat recovery D - With desuperheaters (partial heat recovery) T - With total heat recovery

Evaporator side pumps - without pumps M - low head pump N - low head pump and standby pump O - high head pump P - high head pump and standby pump Condenser side pumps - without pumps U - low head pump V- low head pump and standby pump W - high head pump Z - high head pump and standby pump J - low head inverter pump K - high head inverter pump Combinations not possible: YD, YT, HE, HT, ET, T with evaporator or condenser side pumps.

* only available for sizes 0500-0700 ** only available for sizes 0800-1400 *** "evaporator" is the heat exchanger that works as such in cooling; "condenser" is the heat exchanger that works as such in heating

267

Technical Data
Mod. NXW - L (data declared Eurovent: 12/7C) Size Cooling capacity (E) 400V-3 kW Total input power (E) 400V-3 kW Total current input 400V-3 A Evaporator water flow rate 400V-3 l/h Evaporator pressure drop 400V-3 kPa Condenser water flow rate 400V-3 l/h Condenser pressure drop 400V-3 kPa Heating capacity 400V-3 kW Total input power 400V-3 kW Total current input 400V-3 A Condenser water flow rate Condenser pressure drop Evaporator water flow rate Evaporator pressure drop 400V-3 400V-3 400V-3 400V-3 400V-3 400V-3 400V-3 400V-3 400V-3 l/h kPa l/h kPa W/W A A 0500 112 23.08 48 19264 30 22891 25 119 27.16 53.3 20468 20 16138 21 4.83 4.39 5,73 75 240 0550 120 24.93 51 20812 35 24717 29 129 29.37 56.2 22188 23 17515 25 4.83 4.41 5,71 80 245 0600 148 30.65 58 25628 32 30448 29 161 36.59 65.1 27692 24 21859 23 4.84 4.41 5,76 96 227 0650 166 34.36 63 28724 40 34100 37 182 41.13 71.0 31215 31 24681 29 4.84 4.43 5,85 107 238 0700 188 38.93 86 32508 43 38603 37 205 46.75 92.7 35195 31 27763 31 4.83 4.39 5,76 122 289 750 222 45.59 94 38356 47 45480 45 243 55.09 41595 38 32850 34 4.87 4.41 146 319 800 257 53.00 102 44376 49 52611 60 280 63.75 47995 50 37904 36 4.85 4.40 169 341 900 291 60.28 120 50224 55 59669 38 319 72.25 133.1 54638 32 43140 41 4.82 4.41 193 398 1000 325 66.51 138 56072 35 66611 29 357 80.80 151.9 61281 25 48340 26 4.89 4.42 217 422 1250 354 72.63 140 61060 36 72547 34 388 87.98 157.8 66655 29 52574 27 4.87 4.42 231 490 1400 384 78.66 143 66220 36 78655 36 420 95.11 162.7 72029 30 56807 27 4.88 4.41 248 504

ENERGY EFFICIENCY
E.E.R. (E) COP E.S.E.E.R.

ELECTRICAL DATA
Maximum current Starting current

DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011


(E) EUROVENT per le unit reversibili lato acqua certica le sole rese a freddo (12-7C - 30-35C)

Conditions reference: Cooling: Leaving water temperature 7 C Condenser entering water temperature 30 C t = 5C

Heating: Leaving water temperature 45 C Evaporator entering water temperature 10 C t = 5C

Mod. NXW H - HL (data declared Eurovent: 12/7 C 30/35 C - 10/7C - 40/45C) Size 0500 0550 0600 Cooling capacity 400V-3 kW 106 114 141 Total input power 400V-3 kW 23.92 25.84 31.24 Total current input 400V-3 A 49 52 60 Evaporator water flow rate 400V-3 l/h 18232 19608 24252 Evaporator pressure drop 400V-3 kPa 17 20 19 Evaporator water flow rate 400V-3 l/h 22023 23693 29203 400V-3 kPa 25 29 28 Condenser pressure drop Heating capacity 400V-3 kW 126 136 166 Total input power 400V-3 kW 27.96 30.32 36.86 Total current input 400V-3 A 53 56 65 Condenser water flow rate 400V-3 l/h 21536 23316 28478 Condenser pressure drop 400V-3 kPa 24 28 26 Evaporator water flow rate 400V-3 l/h 28589 30965 37822 400V-3 kPa 43 49 46 Evaporator pressure drop

0650 159 35.39 65 27520 24 33108 35 188 41.75 71 32216 33 42843 58 4.51 4.50 107 238 0650 156 36.9 70 26918 35 4.24 107 238 28/28 28/28

0700 180 40.20 87 31132 24 37488 35 211 46.94 92 36130 32 47999 58 4.49 4.49 122 289 0700 177 41.7 96 30381 38 4.23 122 289 28/28 28/28

750 211 47.13 95 36464 29 43899 42 4.48 146 319 750 209 48.8 105 35935 41 4.28 146 319 28/28 28/28

800 242 54.23 104 41796 38 50293 55 4.46 169 341 800 241 56.5 114 41488 43 4.27 169 341 28/28 28/28

900 277 62.17 122 47816 24 57865 36 326 72.55 133 55886 33 74186 58 4.46 4.49 193 398 900 273 64.7 134 46976 48 4.22 193 398 35/28 35/28

1000 313 70.41 140 54008 19 65250 28 366 80.76 152 62828 26 83446 46 4.45 4.53 217 422 1000 305 72.3 154 52463 31 4.22 217 422 35/35 35/35

1250 341 76.61 144 58824 22 71030 32 400 88.67 158 68702 30 91221 52 4.45 4.52 231 490 1250 332 78.8 156 57187 32 4.22 231 490 35/42 35/35

1400 369 82.74 147 63640 24 76810 34 435 96.49 162 74576 32 99023 58 4.46 4.51 248 504 1400 360 85.3 160 61909 32 4.22 248 504 42/42 35/35

ENERGY EFFICIENCY
E.E.R. COP

400V-3 400V-3 400V-3 400V-3

W/W A A

4.42 4.49 75 240 0500 105 24.9 54 18031 26 4.22 75 240 28/22 28/22

4.40 4.49 80 245 0550 113 26.8 56 19480 31 4.23 80 245 28/22 28/22

4.50 4.51 96 227 0600 139 33.0 65 23988 28 4.22 96 227 28/28 28/28

ELECTRICAL DATA
Maximum current (FLA) Starting current (LRA) Mod. NXW E - EL Size Cooling capacity Total input power Total current input Evaporator water flow rate Evaporator pressure drop

400V-3 400V-3 400V-3 400V-3 400V-3 400V-3

kW kW A l/h kPa W/W A A mm mm

ENERGY EFFICIENCY
E.E.R.

ELECTRICAL DATA
Maximum current (FLA) Starting current (LRA) REFRIGERATION LINES (0 - 10 m) Gas (C1+C2) 400V-3 Liquid (C1+C2) 400V-3 PUMPS EVAPORATOR SIDE Low head pump M - N useful head (cooling) useful head (heating) useful head (a caldo) High head pump O - P useful head (cooling) useful head (cooling) useful head (heating)

kPa kPa kPa kPa

H H

90 106 90.1 192 208 192.6

81 99 80.2 183 202 182.9

68 86 63.0 171 189 166.5

88 109 78.5 211 234 170.8

67 93 59.5 188 214 136.6

99 127 248.1 147 178 312.0

85 101 164.7 167 182 237.3

66 103 74.3 152 187 162.4

72 93 62.6 160 180 153.9

100 120 84.1 148 167 134.2

85 105 63.1 135 154 114.8

268

Size PUMPS CONDENSER SIDE Low head pump U - V - J useful head useful head (cooling) useful head (heating) High head pump W - Z - K useful head useful head (cooling) useful head (heating)

0500

0550

0600

0650

0700

750

800

900

1000

1250

1400

kPa kPa kPa kPa

H H n/n n n n/l bar

84 87 45.4 187 190 148.8 3/2 2"1/2

74 78 29.0 177 180 132.8 3/2 2"1/2

91 98 36.4 155 161 102.6 4/2 2"1/2

65 72 184 192 105.4 4/2 2"1/2

107 115 29.8 156 165 67.7 4/2 2"1/2

87 93 164.7 170 175 237.3 Scroll 4/2 Plate 2"1/2 1 Plate 2"1/2 1 1/25 1,5 86 80 54 48 86 80 54 48

96 106 195.1 142 151 237.3 4/2 2"1/2

101 108 38.3 149 155 89.9 4/2 2"1/2

91 96 17.2 191 197 101.7 4/2 3"

68 75 162 171 56.1 4/2 3"

98 106 134 144 6.4 4/2 3"

Compressor
N compressors/circuits Evaporator Hydraulic connection Quantity Condenser Hydraulic connection Quantity Expansion vessel n/capacity Calibration

2"1/2

2"1/2

2"1/2

2"1/2

2"1/2

2"1/2

2"1/2

3"

3"

3"

1/25 1,5 78 72 46 40 78 72 46 40

1/25 1,5 79 73 47 41 79 73 47 41

1/25 1,5 79 73 47 41 79 73 47 41

1/25 1,5 80 74 48 42 80 74 48 42

1/25 1,5 82 76 50 44 82 76 50 44

1/25 1,5 88 82 56 50 88 82 56 50

1/25 1,5 88 82 56 50 88 82 56 50

1/25 1,5 88 82 56 50 88 82 56 50

1/25 1,5 90 84 58 52 90 84 58 52

1/25 1,5 90 84 58 52 90 84 58 52

SOUND DATA
Sound power Sound pressure Sound power Sound pressure dB(A) dB(A) dB(A) dB(A) L L H HL H HL

Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certication.

Sound pressure: Sound pressure in free eld, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Dimensions (mm)
Mod. NXW / Version "" Size Height(A) (mm) 500 1835 550 1835 600 1835 650 1835 700 1835 750 1775 800 1775 900 1820 1000 1820 1250 1820 1400 1820 Mod. NXW / Version "L" 500 1885 550 1885 600 1885 650 1885 700 1885 750 1885 800 1885 900 1885 1000 1885 1250 1885 1400 1885 Mod. NXW / Version "H" 500 1835 550 1835 600 1835 650 1835 700 1835 750 1775 800 1775 900 1820 1000 1820 1250 1820 1400 1820 Mod. NXW / Version "HL" Size Height(A) (mm) 500 1885 550 1885 600 1885 650 1885 700 1885 750 1885 800 1885 900 1885 1000 1885 1250 1885 1400 1885 Width(B) (mm) 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 Width(B) (mm) 800 800 800 800 800 800 800 800 800 800 800 Length(C) (mm) 1790 1790 1790 1790 1790 2090 2354 2354 2354 2354 2354 2090 2090 2090 2090 2090 2090 2354 2354 2354 2354 2354 1790 1790 1790 1790 1790 2090 2354 2354 2354 2354 2354 Length(C) (mm) 2090 2090 2090 2090 2090 2090 2354 2354 2354 2354 2354 Weight (Kg) 578 582 682 690 727 882 989 1180 1417 1461 1539 750 755 854 863 900 1054 1187 1378 1615 1659 1737 628 633 734 743 791 948 1042 1275 1545 1577 1657 Weight (Kg) 801 805 907 915 963 1121 1240 1473 1743 1775 1855 Mod. NXW / Version with pumps Size Version Height(A) (mm) -H 1775 500 L-HL 1885 -H 1775 550 L-HL 1885 -H 1775 600 L-HL 1885 -H 1775 650 L-HL 1885 -H 1775 700 L-HL 1885 -H 1775 750 L-HL 1885 -H 1775 800 L-HL 1885 -H 1850 900 L-HL 1885 -H 1850 1000 L-HL 1885 -H 1850 1250 L-HL 1885 -H 1850 1400 L-HL 1885 Width(B) (mm) 800 800 800 800 800 800 800 800 800 800 800 Length(C) (mm) 3020 3020 3020 3020 3020 3020 3420 3420 3420 3420 3420

A C

A C

The technical data in this documentation are not binding. Aermec S.p.A. shall have the right to introduce at any time whatever modifications deemed necessary for the improvement of the product.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

269

Code: SNXWUY.05 / 1301

WSA
R134a
Aermec participates in the EUROVENT Program: LCP / W / P / C The products of interest can be found on the website www.eurovent-certication.com

Water cooled chillers and heat pumps with twin-rotor screw compressor Cooling capacity from 147 to 715 kW Heating capacity from 161 to 771 kW

High-efficiency versions

Characteristics
Available in 13 sizes (5 sizes single compressor and 8 sizes dual compressor) Manufactured with refrigerant R134a Versions for cooling only, heat pump or evaporating unit (delivered with holding charge only) Partial or total heat recovery options Standard Version (): - leaving water temperature up to 55 C in heat pump mode Version L: - Low noise with sound absorbent galvanised sheet panels High efficiency, low noise screw compressors with modulating capacity control from 40 to 100% with standard thermostatic expansion valve. (25 to 100% with electronic expansion valve option) Compressor discharge and liquid line isolating valves Current transformer as standard for each compressor Dual refrigerant circuit plate heat exchanger optimised for R134a on dual compressor units Modulating capacity control microprocessor system Independent control for individual circuits Electrical panel with all cables numbered Modulating capacity control with dynamic display of refrigeration capacity Always Working function. In the case of critical conditions the unit will not stop but automatically adjusts operation Automatic set point compensation using analogue inputs 4-20 mA or 010 V or an external air sensor Auto-adaptive differential to ensure correct compressor operating timers PDC (Pull Down Control) system which prevents capacity loading when the water temperature quickly approaches the set point DL (Demand Limit) system permits current limiting of the unit during times of insufficient electrical power (load peaks or generator operation) Compact dimensions Multilingual display panel Metal control panel with anti-corrosion polyester paint

Accessories
AER485P1: RS-485 interface for supervision systems with MODBUS protocol. PRV3: Remote control of the chiller operating functions. RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted only. AVX: Spring anti-vibration mounts. AERWEB300 : Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: - AERWEB300-6: Web server to monitor and MULTICHILLER: Control system for multiple remote control max. 6 units in RS485 netparallel installed constant flow chillers prowork; viding individual chiller on/off and control - AERWEB300-18: Web server to monitor and capability. remote control max. 18 units in RS485 net- AKW: ACOUSTIC KIT: Allows further unit work; sound reduction using an optimised enclosure - AERWEB300-6G: Web server to monitor and made from a high density ecological material. remote control max. 6 units in RS485 network with integrated GPRS modem; - AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; SAP: A series of remote buffer tanks and pumps are available. Refer to the technical manual.

270

Accessory compatibility
Mod Vers. AERWEB300 MULTICHILLER AER485P1 RIF PRV3 /L E AVX D DE T AKW 0601 651 0701
161

0801
161

0901
201

1101
241

1202 (x2)
-

1402 (x2)
161(x2)

1602 (x2)
161(x2)

1802 (x2)
201(x2)

2002 (x2)
201-241

2202 (x2)
241(x2)

2502 (x2)
301(x2)

2802 (x2)
301(x2)

651 668 651 668 652

652 668 652 668 655

652 668 652 668 655

656 669 654 669 657

658

658 670 658 670 662

658 670 659 670 662

659 670 659 670 662

667 671 667 671 663

661 672 661 672 664

661 672 661 672 664

661 672 661 672 664

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system requirements.

Fields configurator:
123 Code 4567 Size 8 Expansion device 9 Model 10 Heat recovery 11 Version 12 Condenser 13 Power supply

Code: WSA Size: 601, 0701, 0801, 0901, 1101, 1202, 1402, 1602, 1802, 2002, 2202, 2502, 2802 Expansion device: - Standard, minimum leaving water temperature down to +4 C X - With electronic expansion valve max. temp. of water produced: +4C (for lower temperatures please contact us) Model: - Standard Heat recovery: - Without heat recovery D - With desuperheaters (partial heat recovery) (not available for the size 0601 and 1202) T - With total heat recovery (not available for the size 0601 and 1202)

Version: - Standard L - Low noise Condenser: - PED regulation E - Evaporating unit (delivered with holding charge only) Power supply: - 400V 3~ 50Hz with fuses 8 - 400V 3~ 50Hz with circuit breakers 2 - 230V 3~ 50Hz with fuses * 4 - 230V 3~ 50Hz with circuit breakers * * (not available for sizes 2502 and 2802) 5 - 500V 3~ 50Hz with fuses 9 - 500V 3~ 50Hz with circuit breakers

Attention: The standard options are shown by the symbol Example of configuration code: WSA1602L8 This is a WSA unit, size 1602 in low noise version, with heat exchangers to PED regulations, and with electrical panel and compressor motors at 400V 3~ 50Hz with circuit breakers. Since each option is uniquely identified it is not necessary to indicate the standard options (represented by ) in the unit configurator.

271

Technical Data
Mod WSA Cooling capacity (E) kW Total input power (E) kW Water flow rate evaporator l/h Pressure drop evaporator kPa Water flow rate condenser l/h Pressure drop condenser kPa Heating capacity kW Total input power kW Water flow rate condenser l/h Pressure drop condenser kPa Water flow rate evaporator l/h Pressure drop evaporator kPa E.E.R. (E) W/W EEEC(1) C.O.P W/W EEEC(1) Power supply Input current cooling A Input current heating A Maximum current (FLA) A Starting current (LRA) A Compressor Type Quantity n Part load (standard expansion valve) % Part load (electronic expansion valve) % Evaporator Type Quantity n Evaporator hydraulic connection Hydraulic connection type Type Condenser Type Quantity n Condenser hydraulic connection Hydraulic connection type Type Sound pressure(2) dB(A) 0601
146 31,75 25284 29 30268 40 161 36,93 27520 31 21638 19 4,61 B 4,35 B 56 67 105 180 1 40-100 25-100 1 3"

0701
179 38,10 30788 20 36834 27 192 44,08 32852 41 25826 12 4,69 B 4,35 B 66 73 124 163 1 40-100 25-100 1 3

0801
212 43,24 36636 20 43499 27 219 48,85 37496 20 29653 12 4,91 A 4,47 A 74 82 144 192 1 40-100 25-100 1 3

0901
233 49,28 40248 19 48091 26 246 56,89 42140 19 32990 12 4,74 B 4,32 B 82 91 162 229 1 40-100 25-100 1 3

1101
293 59,68 50568 23 60045 31 309 71,20 52976 24 41538 14 4,91 A 4,34 B 101 117 182 300 1 40-100 25-100 1 3

1202
293 63,52 50568 38 60535 53 320 73,83 54868 42 43103 25 4,61 B 4,34 B 112 133 210 285

1402
356 76,83 61404 36 73496 50 376 87,85 64500 36 50448 22 4,63 B 4,28 B 132 146 248 287

1602

1802

2002

2202

2502

2802

422 468 527 586 660 712 86,53 101,02 110,73 120,50 137,70 148,19 72756 80840 90988 101136 114036 122980 40 41 45 48 53 62 86318 96690 108308 119927 135441 145856 55 58 62 67 75 88 435 493 559 627 690 771 99,22 113,57 129,03 143,58 155,22 178,00 74648 84452 95804 107500 118164 131924 39 42 46 50 55 74 58798 66315 75216 84624 93491 103819 24 25 27 29 32 44 4,87 4,64 4,76 4,86 4,80 4,80 A B B A A A 4,39 4,34 4,33 4,37 4,44 4,33 A B B A A A 148 164 288 336 164 183 324 391 184 209 344 462 203 235 364 482 233 257 430 575 233 258 430 575

400V/3/50Hz

Twin-rotor screw
2 2 2 2 2 2 2 2 20-100 20-100 20-100 20-100 20-100 20-100 20-100 20-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100

Plate
1 3" 1 3 1 3 1 3 1 3 1 3 1 3 1 3

Victaulic Plate
1 3 53 1 3 54 1 3 54 1 3 54 1 3 60 1 3" 56 1 3 57 1 3 57 1 3 57 1 3 61 1 3 63 1 3 63 1 3 63

Victaulic

Data declared in accordance with UNI EN 14511:2011 (E) EUROVENT for reversible units side water certifies the sun made cold (12-7 C - 30-35 C) Mod WSA - E Cooling capacity Total input power Water flow rate evaporator (7 C) Pressure drop evaporator E.E.R. EEEC(1) Power supply Input current cooling Maximum current (FLA) Starting current (LRA) Compressor Quantity Part load (standard expansion valve) Part load (electronic expansion valve) Evaporator Quantity Evaporator hydraulic connection Hydraulic connection type Sound pressure(2) kW kW l/h kPa W/W A A A Type n % % Type n Type dB(A) 1402 1602 1802 2002 2202 2502 2802 326 385 428 481 539 601 676 82 93 108 120 132 146 159 56070 66220 73620 82790 92710 103370 116270 33 37 38 40 45 49 59 3.98 4.14 3.96 4.00 4.08 4.12 4.25 A A A A A A A 400V 3~ 50 Hz 72 81 90 113 144 162 180 204 226 254 272 124 144 162 182 248 288 324 344 364 430 430 163 192 229 300 287 336 391 462 482 575 575 Twin-rotor screw 1 1 1 1 2 2 2 2 2 2 2 40-100 40-100 40-100 40-100 20-100 20-100 20-100 20-100 20-100 20-100 20-100 25-100 25-100 25-100 25-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 Plate 1 1 1 1 1 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 3 3 Victaulic 54 54 54 60 57 57 57 63 63 63 63 0701 163 41 28040 18 3.98 A 0801 192 47 33020 18 4.09 A 0901 212 54 36460 17 3.93 A 1101 263 66 45240 21 3.98 A

The sizes 0601 and 1202 is not available without condenser (1) EEEC EUROVENT energy efficiency class (2) Sound pressure measured in free field with directivity factor 2 at 10 m distance, in accordance with ISO 3744.

Cooling: leaving water temperature 7 C entering condenser water temperature 30 C t = 5K Evaporating unit: leaving evaporator water temperature 7 C refrigerant condensing temperature 45 C t = 5K

Heating: leaving water temperature 45 C entering evaporator water temperature 10 C t = 5K

272

Dimensions (mm)

Mod WSA (E - L) Height (A) - E Height (A) L - LE Width (B) Length (C) Weight

mm mm mm mm kg () kg (L) kg (D/DE)

0601 1775 1775 810 2960 1101 1229 -

0701 1775 1775 810 2960 1251 1379 1479

0801 1775 1775 810 2960 1301 1429 1529

0901 1775 1775 810 2960 1357 1485 1585

1101 1775 1775 810 3360 1788 1934 2045

1202 1975 2120 810 2960 1738 1966 -

1402 1975 2120 810 2960 2028 2256 2256

1602 1975 2120 810 2960 2097 2325 2325

1802 2005 2120 810 2960 2169 2397 2397

2002 1985 2120 810 3360 2598 2855 2855

2202 2065 2120 810 3360 3000 3257 3257

2502 2065 2120 810 3360 3095 3352 3352

2802 2065 2120 810 3360 3095 3352 3352

Mod WSA ( - L) Height (A) Height (A) L Width (B) Length (C) Weight

mm mm mm mm kg

0601T 0701 T 0801 T 0901 T 1101 T 1202T 1402 T 1602 T 1802 T 2002 T 2202 T 2502 T 2802 T 2000 2000 2000 2000 2050 2050 2050 2050 2065 2065 2065 2120 2120 2120 2120 2120 2120 2120 2120 2120 2120 2120 810 810 810 810 1250 1250 1250 1250 1250 1250 1250 2960 2960 2960 3360 3060 3060 3060 3460 3460 3460 3460 1479 1529 1585 2045 2294 2363 2435 2894 3296 3391 3391

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

273

Cod.: SWSAUY.16 / 1301

WSB
R134a
Aermec participates at EUROVENT program: LCP / W / P / C The involved products can be found in the website www.eurovent-certification.com

Water cooled chillers and heat pumps with twin-rotor screw compressor Cooling capacity from 171 to 701 kW Heating capacity from 185 to 743 kW

Feaures
Available in 11 sizes (4 sizes single compressor and 7 sizes dual compressor) Manufactured with refrigerant R134a Versions for cooling only, heat pump or evaporating unit (delivered with holding charge only) Partial or total heat recovery options Standard Version (): - leaving water temperature up to 55 C in heat pump mode Version L: - Low noise with sound absorbent galvanised sheet panels High efficiency, low noise screw compressors with modulating capacity control from 40 to 100% with standard thermostatic expansion valve. (25 to 100% with electronic expansion valve option) Compressor discharge and liquid line isolating valves Current transformer as standard for each compressor Dual refrigerant circuit plate heat exchanger optimised for R134a on dual compressor units Modulating capacity control microprocessor system Independent control for individual circuits Electrical panel with all cables numbered Modulating capacity control with dynamic display of refrigeration capacity Always Working function. In the case of critical conditions the unit will not stop but automatically adjusts operation Automatic set point compensation using analogue inputs 4-20 mA or 010 V or an external air sensor Auto-adaptive differential to ensure correct compressor operating timers PDC (Pull Down Control) system which prevents capacity loading when the water temperature quickly approaches the set point DL (Demand Limit) system permits current limiting of the unit during times of insufficient electrical power (load peaks or generator operation) Compact dimensions Multilingual display panel Metal control panel with anti-corrosion polyester paint

Accessories
AER485P1: RS-485 interface for supervision systems with MODBUS protocol. PRV3: Remote control of the chiller operating functions. RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted only. AVX: Spring anti-vibration mounts. AERWEB300 : Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: work with integrated GPRS modem; - AERWEB300-6: Web server to monitor and SAP: A series of remote buffer tanks and pumps remote control max. 6 units in RS485 netare available. Refer to the technical manual. work; MULTICHILLER: Control system for multiple - AERWEB300-18: Web server to monitor and parallel installed constant flow chillers providremote control max. 18 units in RS485 neting individual chiller on/off and control capawork; bility. - AERWEB300-6G: Web server to monitor and AKW: ACOUSTIC KIT: Allows further unit remote control max. 6 units in RS485 netsound reduction using an optimised enclosure. work with integrated GPRS modem; - AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 net-

274

Accessory compatibility
Mod Vers. AERWEB300 MULTICHILLER AER485P1 RIF PRV3 /L E AVX D T DE AKW 0701 161 651 668 651 651 668 0801 161 651 668 651 652 668 0901 201 651 668 652 652 668 1101 241 653 669 653 654 669 1402 (x2) 161(x2) 656 670 658 662 670 1602 (x2) 161(x2) 658 670 658 662 670 1802 (x2) 201(x2) 658 670 659 662 670 2002 (x2) 201-241 667 671 667 663 671 2202 (x2) 241(x2) 660 672 660 664 672 2502 (x2) 301(x2) 661 672 661 664 672 2802 (x2) 301(x2) 661 672 661 664 672

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system requirements.

Configuration Fields: 1 2 3 4 5 6 7 8 9 10 11 12 13 | | | | | | | | Code | Expansion device | Heat recovery | Condenser | | | | | Size Model Version Power supply

Code: WSB Size: 0701, 0801, 0901, 1101, 1402, 1602, 1802, 2002, 2202, 2502, 2802 Expansion device: - Standard, minimum leaving water temperature down to +4 C X - With electronic expansion valve Model: - Standard Heat recovery: - Without heat recovery D - With desuperheaters (partial heat recovery) T - With total heat recovery Version: - Standard L - Low noise

Condenser: - PED regulation E - Evaporating unit (delivered with holding charge only) Power supply: - 400V 3~ 50Hz with fuses 8 - 400V 3~ 50Hz with circuit breakers 2 - 230V 3~ 50Hz with fuses * 4 - 230V 3~ 50Hz with circuit breakers * * (not available for sizes 2502 and 2802) 5 - 500V 3~ 50Hz with fuses 9 - 500V 3~ 50Hz with circuit breakers

Attention: The standard options are shown by the symbol Example of configuration code: WSB1602L8 This is a WSB unit, size 1602 in low noise version, with heat exchangers to PED regulations, and with electrical panel and compressor motors at 400V 3~ 50Hz with circuit breakers. Since each option is uniquely identified it is not necessary to indicate the standard options (represented by ) in the unit configurator.

275

Technical Data
Mod WSB Cooling capacity (E) Total input power (E) Water flow rate evaporator Pressure drop evaporator Water flow rate condenser Pressure drop condenser Heating capacity Total input power Water flow rate condenser Pressure drop condenser Water flow rate evaporator Pressure drop evaporator E.E.R. (E) EEEC(1) C.O.P. EEEC(1) Power supply Input current cooling Input current heating Maximum current (FLA) Starting current (LRA) Compressor Quantity Part load (standard expansion valve) Part load (electronic expansion valve) Evaporator Quantity Evaporator hydraulic connection Hydraulic connection type Condenser Quantity Condenser hydraulic connection Hydraulic connection type Sound pressure 1402 1602 1802 343 395 451 77,77 88,57 101,96 59168 68284 77916 52 57 54 71260 82010 93766 73 79 77 362 418 475 89,42 100,85 115,12 62092 71724 81528 54 57 56 47876 55711 63227 31 34 33 4,40 4,46 4,42 B B B W/W 4,05 4,14 4,13 B B B 400V 3~ 50Hz A 66 74 82 102 132 149 165 A 73 82 91 118 147 166 184 A 124 144 162 182 248 288 324 A 163 192 229 300 287 336 391 Type Twin-rotor screw n 1 1 1 1 2 2 2 % 40-100 40-100 40-100 40-100 20-100 20-100 20-100 % 25-100 25-100 25-100 25-100 12,5-100 12,5-100 12,5-100 Type Plate n 1 1 1 1 1 1 1 3 3 3 3 3 3 3 Type Victaulic Type Plate n 1 1 1 1 1 1 1 3 3 3 3 3 3 3 Type Victaulic dB(A) 58 58 59 60 61 61 62 kW kW l/h kPa l/h kPa kW kW l/h kPa l/h kPa W/W 0701 171 38,75 29584 40 35630 56 185 45,21 31648 41 24458 24 4,42 B 4,09 B 0801 200 43,75 34572 35 41435 48 211 50,21 36292 35 28285 21 4,58 B 4,21 B 0901 225 50,73 38872 30 46879 42 241 57,22 41452 31 32302 19 4,44 B 4,22 B 1101 280 60,23 48332 34 57809 47 304 72,55 52116 36 40515 21 4,65 B 4,18 B 2002 505 112,60 87204 56 104688 79 541 130,76 92880 63 72128 34 4,48 B 4,14 B 184 210 344 462 2202 564 123,34 97352 58 116470 82 607 145,18 104232 62 81193 36 4,57 B 4,18 B 205 237 364 482 2502 645 139,03 111456 57 133025 81 679 157,44 116444 59 91444 35 4,64 B 4,31 B 233 259 430 575 2802 701 148,65 121088 67 143964 95 743 179,19 127452 80 99184 47 4,71 B 4,15 B 233 259 430 575

2 2 2 2 20-100 20-100 20-100 20-100


12,5-100 12,5-100 12,5-100 12,5-100

1 3 1 3 63

1 3 1 3 63

1 3 1 3 63

1 3 1 3 63

Data declared in accordance with UNI EN 14511:2011 (E) EUROVENT for reversible units side water certifies the sun made cold (12-7 C - 30-35 C) Mod WSB - E Cooling capacity Total input power Water flow rate evaporator (7 C) Pressure drop evaporator E.E.R. EEEC(1) Power supply Input current cooling Maximum current (FLA) Starting current (LRA) Compressor Quantity Part load (standard expansion valve) Part load (electronic expansion valve) Evaporator Quantity Evaporator hydraulic connection Hydraulic connection type Sound pressure(2) 1402 1602 1802 2002 2202 2502 2802 311 365 410 465 521 594 665 82 92 107 120 131 146 159 53490 62780 70520 79924 89610 102170 114380 48 53 50 51 54 53 64 3.79 3.97 3.83 3.88 3.98 4.07 4.18 A A A A A A A 400V 3~ 50Hz A 71 81 89 113 143 161 178 203 226 254 272 A 124 144 162 182 248 288 324 344 364 430 430 A 225 264 310 391 287 336 391 462 482 575 575 Type Twin-rotor screw n 11 1 1 1 2 2 2 2 2 2 2 % 40-100 40-100 40-100 40-100 20-100 20-100 20-100 20-100 20-100 20-100 20-100 % 25-100 25-100 25-100 25-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 12,5-100 Type Plate n 1 1 1 1 1 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 3 3 Type Victaulic dB(A) 58 58 59 60 61 61 62 61 63 63 63 kW kW l/h kPa W/W 0701 155 41 26660 40 3.78 A 0801 185 46 31820 35 4.02 A 0901 207 53 35600 30 3.91 A 1101 258 66 44380 34 3.91 A

(1) EEEC EUROVENT energy efficiency class (2) Sound pressure measured in free field with directivity factor 2 at 10 m distance, in accordance with ISO 3744.

Cooling: leaving water temperature 7 C entering condenser water temperature 30 C t = 5K Evaporating unit: leaving evaporator water temperature 7 C refrigerant condensing temperature 45C t = 5K

Heating: leaving water temperature 45C entering evaporator water temperature 10C t = 5K

276

Dimensions (mm)

Mod WSB ( - L) Height (A) Height (A) L Width (B) Length (C) Weight

mm mm mm mm kg () kg (L) kg (D/DE)

0701 1775 1775 810 2960 1251 1379 1479 0701 T 2000 2120 810 2960 1479

0801 1775 1775 810 2960 1301 1429 1529 0801 T 2000 2120 810 2960 1529

0901 1775 1775 810 2960 1357 1485 1585 0901 T 2000 2120 810 2960 1585

1101 1775 1775 810 3360 1788 1934 2045 1101 T 2000 2120 810 3360 2045

1402 1975 2120 810 2960 2028 2256 2256 1402 T 2050 2120 1250 3060 2294

1602 1975 2120 810 2960 2097 2325 2325 1602 T 2050 2120 1250 3060 2363

1802 2005 2120 810 2960 2169 2397 2397 1802 T 2050 2120 1250 3060 2435

2002 1985 2120 810 3360 2598 2855 2855 2002 T 2050 2120 1250 3460 2894

2202 2065 2120 810 3360 3000 3257 3257 2202 T 2065 2120 1250 3460 3296

2502 2065 2120 810 3360 3095 3352 3352 2502 T 2065 2120 1250 3460 3391

2802 2065 2120 810 3360 3095 3352 3352 2802 T 2065 2120 1250 3460 3391

Mod WSB ( - L) Height (A) Height (A) L Width (B) Length (C) Weight

mm mm mm mm kg

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

277

Cod.: SWSBUY.11 / 1301

WSH
R134a

Water cooled reverse cycle heat pumps with twin-rotor screw compressor Cooling capacity from 166 to 668 kW Heating capacity from 190 to 819 kW

Aermec participate in the EUROVENT program: LCP / W / P / R the products are present on the site www.eurovent-certification.com

REFRIGERANT REVERSING VALVE OPTIONAL ELECTRONIC EXPANSION VALVE WHICH ALLOWS: - COOLING DOWN TO -6 C - MODULATING CAPACITY CONTROL 25-100%

Characteristics
Available in 10 sizes (4 sizes single compressor and 6 sizes dual compressor) Manufactured with refrigerant R134a Versions for cooling only - heat pump with refrigerant reversing valve Partial heat recovery option Standard Version (): - leaving water temperature up to 55 C in heat pump mode Version X: - leaving liquid temperature down to -6 C Version L: - low noise High efficiency, low noise screw compressors with modulating capacity control from 40 to 100% with standard thermostatic expansion valve. (25 to 100% with electronic expansion valve option) Compressor discharge and liquid line isolating valves Current transformer as standard for each compressor Dual refrigerant circuit plate heat exchanger optimised for R134a on dual compressor units Modulating capacity control microprocessor system Independent control for individual circuits Electrical panel with all cables numbered Modulating capacity control with dynamic display of refrigeration capacity Always Working function. In the case of critical conditions the unit will not stop but automatically adjusts operation Automatic set point compensation using analogue inputs 4-20 mA or 010 V or an external air sensor Auto-adaptive differential to ensure correct compressor operating timers PDC (Pull Down Control) system which prevents capacity loading when the water temperature quickly approaches the set point DL (Demand Limit) system permits current limiting of the unit during times of insufficient electrical power (load peaks or generator operation) Compact dimensions Multilingual display panel Metal control panel with anti-corrosion polyester paint

Accessories
AER485P1: RS-485 interface for supervision AERWEB300-6: Web server to monitor and are available. Refer to the technical manual. systems with MODBUS protocol. remote control max. 6 units in RS485 net- MULTICHILLER: Control system for multiple PRV3: Remote control of the chiller operating work; parallel installed constant flow chillers providfunctions. AERWEB300-18: Web server to monitor and ing individual chiller on/off and control capa RIF: Power factor correction. Connected in parremote control max. 18 units in RS485 netbility. allel to the motor allowing about 10% reducwork; AKW: ACOUSTIC KIT: Allows further unit tion of input current. Must be requested at time AERWEB300-6G: Web server to monitor and sound reduction using an optimised enclosure of order and is available factory fitted only. remote control max. 6 units in RS485 netmade from a high density ecological material. AVX: Spring anti-vibration mounts. work with integrated GPRS modem; AERWEB300: Accessory AERWEB allows AERWEB300-18G: Web server to monitor and remote control of a chiller through a comremote control max. 18 units in RS485 netmon PC and an ethernet connection over a work with integrated GPRS modem; common browser; 4 versions available: SAP: A series of remote buffer tanks and pumps

278

Accessory compatibility
Mod AERWEB300 MULTICHILLER AER485P1 RIF PRV3 AVX AKW Vers.
-

/L D
-

0701 161 665 665

0801 161 665 665

0901 201 665 665

1101 241 666 666

1402 (x2) 161(x2) 662 662

1602 (x2) 161(x2) 662 662

1802 (x2) 201(x2) 662 662

2002 (x2) 201-241 663 663

2202 (x2) 241(x2) 664 664

2502 (x2) 301(x2) 664 664

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system requirements.

Configuration Fields: 1 2 3 4 5 6 7 8 9 10 11 12 13 | | | | | | | | Code | Expansion device | Heat recovery | Condenser | | | | | Size Model Version Power supply

Code: WSH Size: 0701, 0801, 0901, 1101, 1402, 1602, 1802, 2002, 2202, 2502 Expansion device: - Standard, minimum leaving water temperature down to +4 C X - With electronic expansion valve that allows: - Leaving liquid temperature down to -6 C - Modulating capacity control (25 - 100%) Model: - Standard Heat recovery: - Without heat recovery D - With desuperheaters (partial heat recovery) Version: - Standard

L - Low noise Condenser: - PED regulation Power supply: - 400V 3~ 50Hz with fuses 8 - 400V 3~ 50Hz with circuit breakers 2 - 230V 3~ 50Hz with fuses * 4 - 230V 3~ 50Hz with circuit breakers * * (not available for size 2502) 5 - 500V 3~ 50Hz with fuses 9 - 500V 3~ 50Hz with circuit breakers

Attention: The standard options are shown by the symbol Example of configuration code: WSH1602L8 This is a WSH unit, size 1602 in low noise version, with heat exchangers to PED regulations, and with electrical panel and compressor motors at 400V 3~ 50Hz with circuit breakers. Since each option is uniquely identified it is not necessary to indicate the standard options (represented by ) in the unit configurator.

279

Technical Data
Mod WSH Cooling capacity Total input power Water flow rate evaporator Pressure drop evaporator Water flow rate condenser Pressure drop condenser Heating capacity Total input power Water flow rate condenser Pressure drop condenser Water flow rate evaporator Pressure drop evaporator E.E.R. EEEC(1) C.O.P. EEEC(1) Power supply Input current cooling Input current heating Maximum current (FLA) Starting current (LRA) Compressor Part load (standard expansion valve) Part load (electronic expansion valve) Evaporator Quantity Evaporator hydraulic connection Hydraulic connection type Condenser Quantity Condenser hydraulic connection Hydraulic connection type Sound pressure Sound power 0701 166 37,14 28552 23 34434 30 190 45,84 32651 26 42361 46 4,46 C 4,15 B 65 81 124 163 40-100 25-100 1 3 1 3 54 86 0801 195 42,31 33712 24 40411 31 218 52,05 37468 25 48746 46 4,62 B 4,20 B 73 91 144 192 40-100 25-100 1 3 1 3 54 86 0901 216 48,35 37324 22 45004 30 247 59,19 42286 25 54856 43 4,48 C 4,17 B 80.6 101 162 229 40-100 25-100 1 3 1 3 54 86 1101 269 58,78 46440 27 55754 36 312 75,13 53526 31 69480 55 4,58 B 4,15 B 100 130.5 182 300 40-100 25-100 1 3 1 3 60 92 1402 1602 359 426 79,23 92,02 61920 73616 43 47 74338 87995 57 62 438 511 104,03 123,32 74937 87426 61 67 98039 113923 82 89 4,53 4,63 B B 4,21 4,14 B B 400V 3~ 50Hz 135 146.5 178.5 210 248 288 287 336 Twin-rotor screw 20-100 20-100
12,5-100 12,5-100

kW kW l/h kPa l/h kPa kW kW l/h kPa l/h kPa W/W W/W A A A A Type % % Type n Type Type n Type db(A) db(A)

1802 464 103,47 80152 48 96329 65 563 133,01 96346 68 126325 89 4,49 B 4,23 B 162 221 324 391 20-100
12,5-100

2002 524 114,87 90472 59 108273 79 647 153,87 110620 77 144907 98 4,56 B 4,20 B 187.5 256.5 344 462 20-100
12,5-100

2202 591 127,11 102168 65 121776 88 730 173,98 124894 85 163764 110 4,65 B 4,20 B 210 291 364 482 20-100
12,5-100

2502 668 146,90 115584 74 138133 101 819 190,54 139881 97 184907 122 4,55 B 4,30 A 242 320 430 575 20-100
12,5-100

Plate 1 1 3 3 Victaulic Plate 1 1 3 3 Victaulic 57 57 89 89

1 3 1 3 57 89

1 3 1 3 61 93

1 3 1 3 63 95

1 3 1 3 63 95

(1) EEEC EUROVENT energy efficiency class

Data declared in accordance with UNI EN 14511:2011 Cooling Evaporator leaving water temperature 7 C entering condenser water temperature 12 C Condenser leaving water temperature 35 C entering condenser water temperature 30 C Heating Evaporator leaving water temperature 7 C entering condenser water temperature 10 C Condenser leaving water temperature 45 C entering condenser water temperature 40 C

Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

280

Dimensions (mm)

C B

Mod WSH Height (A) Width (B) Length (C) Weight (empty) () L mm mm mm mm kg () kg (D)

0701 1980 2120 810 2960 1391 1622

0801 1980 2120 810 2960 1443 1674

0901 1980 2120 810 2960 1506 1737

1101 2060 2120 810 3360 1946 2200

1402 2000 2120 1260 3060 2276 2542

1602 2000 2120 1260 3060 2350 2616

1802 2000 2120 1260 3060 2423 2689

2002 2000 2120 1260 3460 2872 3168

2202 2060 2120 1260 3460 3309 3605

2502 2060 2120 1260 3460 3407 3703

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

281

Cod.: SWSHUY.07 / 1301

TW110
R134a
Aermec participates in the EUROVENT Program: LCP / W / P / C The products of interest can be found on the website www.eurovent-certication.com

Water cooled modular chiller with centrifugal compressor

Characteristics
Cooling only version New generation two-stage oil free centrifugal compressor with magnetic levitation friction free bearings Plate heat exchangers optimised for use with refrigerant R134a Extremely compact: only 805 mm wide to allow access through a standard doorway Component layout designed to enable several units to be positioned side by side in restricted plant rooms. Ideal when standby is required or when cooling duty is to be increased at a later date High efficiency with generously sizes heat exchanger Extraordinary efficiency at part load (up to active controls 30% higher IPLV when compared with Microprocessor control system standard chillers) LCD user interface: colour touch-screen with Electronic expansion valve simple and intuitive graphical menu Acoustic enclosure: heavy gauge galvanized Compressor features: sheet steel with internal acoustic insulation. Operates without oil as bearings are magnetic levitation type. Vibration free and very quiet Provided with inverter technology that permits capacity modulation down to 25% Integrated controller that reduces starting current to 6 A only 5 times lighter than an equivalent screw compressor Electronic controller for monitoring and pro-

Accessories
AER485P1TW: RS-485 interface for supervision systems with MODBUS protocol. PTW: Remote control of chiller operating functions. MULTICHILLER: Control system for multiple parallel installed constant flow chillers providing individual chiller on/off and control capability. (When this accessory is present, the AER485P1TW is factory fitted as standard).

282

Technical data
Mod. Cooling capacity Total input power Evaporator water flow rate (7 C) Evaporator pressure drop Condenser water flow rate (30 C) Condenser pressure drop ENERGY INDEX EER ESEER ELECTRICA DATA Power supply Input current Maximum current (FLA) Starting current (LRA) SOUND DATA Sound pressure Sound power HYDRAULIC CONNECTION Evaporator hydraulic connection (Victaulic) Condenser hydraulic connection (Victaulic) Data declared in accordance with UNI EN 14511:2011 kW kW l/h kPa l/h kPa W/W W/W A A A dB(A) dB(A) TW 110 284 58,47 49020 30 58236 43 4,86 7,05 400V 3~ 50Hz 88 134 6 77 49 3 3 Cooling leaving water temperature 7C; condenser entering water temperature 30 C; t = 5 C; Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

Dimensions (mm)

A
OUT Condenser IN evaporator

IN Condenser

OUT evaporator

C B
Model Height Width Depth Weight TW 110 1727 805 1653 960

[mm] (A) [mm] (B) [mm] (C) kg

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

283

Cod.: STWUY.04 / 1302

WF
R134a

Water cooled chillers with twin-rotor screw compressor Cooling capacity from 630 to 1549 kW Heating capacity from 678 to 1654 kW

ENERG
Range Model

IJA IE

IA EFFICIENCY CLASS

ENERG
Range Model

IJA IE

IA EFFICIENCY CLASS

MANUFACTURER
www.eurovent-certification.com

MANUFACTURER
www.eurovent-certification.com

HEAT PUMP LOCAL DESIGNATION LOCAL DESIGNATION Heating mode at full load A B

LIQUID CHILLING PACKAGE LOCAL DESIGNATION LOCAL DESIGNATION Cooling mode at full load

A B C D E
Rf. : 08-201103

Aermec participate in the EUROVENT program: LCP / W / P / R up to 1500 kW. the products are present on the site www.eurovent-certification.com * Not certified model

C D E
Rf. : 08-201103

F G
RS 6/C/003-2011 and RS 6/C/003A-2011

F G
RS 6/C/003-2011 and RS 6/C/003A-2011

OPTIMISED FOR LOW CONDENSER TEMPERATURES for example: units working in cooling mode with ground or tower water, or units working in heat pump mode with low leaving water temperature STANDARD AND HIGH EFFICIENCY VERSIONS MAXIMUM CONDENSER LEAVING WATER TEMPERATURE: 50C SHELL AND TUBE HEAT EXCHANGERS STANDARD ELECTRONIC EXPANSION VALVE WHICH ALLOWS: - COOLING DOWN TO -6 C - ADJUSTMENT OF THE COOLING CAPACITY VIA CONTINUOUS MODULATION 12.5-100%
Characteristics
- Available in 8 sizes - Two independent refrigerant circuits - High efficiency screw compressors optimised for R134a - Heat exchangers with oversized surface areas - Electronic expansion valve as standard - Compact dimensions - Suitable for use in heat pump mode with leaving water temperature up to 50 C (with hydraulic system reversing) and with ground water or geothermal loops. For heating mode operation the IS accessory, condenser isolating valves, is required Operational limits: - condenser leaving water temperature up to 50 C - evaporator leaving liquid temperature down to -6 C Options available: - partial heat recovery - total heat recovery - evaporating unit - low noise unit with compressor acoustical enclosures made from galvanised steel and high density sound absorbent material Modulating capacity control microprocessor system - Redundancy of the unit (one microprocessor per circuit) - Leaving water temperature control with modulating capacity control (12.5-100% for each compressor) and dynamic display of the refrigeration capacity - Condensing control based on pressure with 0-10 Vdc signal for controlling a modulating valve / variable speed pump - Electrical panel with all cables numbered - Current transformer as standard for each compressor - Always Working function. In the case of critical conditions the unit will not stop but automatically adjusts operation - Automatic set point compensation using analogue inputs 4-20 mA or 010 V or an external air sensor - Auto-adaptive differential to ensure correct compressor operating timers - PDC (Pull Down Control) system which prevents capacity loading when the water temperature quickly approaches the set point - DL (Demand Limit) system permits current limiting of the unit during times of insufficient electrical power (load peaks or generator operation) - Multilingual display panel

Accessories
AER485P1: RS-485 interface for supervision systems with MODBUS protocol. PRV3: Remote control of the chiller operating functions. RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted only. AVX: Spring anti-vibration mounts. AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: MULTICHILLER: Control system for multiple parallel installed constant flow chillers proAERWEB300-6: Web server to monitor and viding individual chiller on/off and control remote control max. 6 units in RS485 netcapability. work; AERWEB300-18: Web server to monitor and AKW: ACOUSTIC KIT: Allows further unit sound reduction using an optimised encloremote control max. 18 units in RS485 netsure made from a high density ecological work; material. Only available for L Versions. AERWEB300-6G: Web server to monitor and Factory fitted only. remote control max. 6 units in RS485 net IS: Condenser isolating valves. Mandatory work with integrated GPRS modem; accessory for units operating in heat pump AERWEB300-18G: Web server to monitor and mode. Factory fitted only. remote control max. 18 units in RS485 network with integrated GPRS modem;

284

Mod AERWEB300 MULTICHILLER AER485P1 PRV3 AVX RIF AKW(WF-L) IS1 IS2 IS3

Accessory compatibility 2512 2812 3212 3612 4212 4812 5612 6412 (x2) (x2) (x2) (x2) (x2) (x2) (x2) (x2) RIFWF2512 RIFWF2812 RIFWF3212 RIFWF3612 RIFWF4212 RIFWF4812 RIFWF5612 RIFWF6412 /A /A A A A A A A AVX compatibility

Standard/Low noise Mod WF AVX Mod WF AVX High efficiency/High efficiency low noise Mod WF AVX Mod WF AVX

2512 673 2512L 673 2512A 673 2512AL 674

2812 673 2812L 673 2812A 673 2812AL 674

3212 673 3212L 674 3212A 674 3212AL 675

3612 674 3612L 674 3612A 675 3612AL 675

4212 674 4212L 674 4212A 675 4212AL 675

4812 674 4812L 674 4812A 675 4812AL 675

5612 675 5612L 675 5612A 676 5612AL 676

6412 675 6412L 675 6412A 676 6412AL 676

RIF - AKW - IS are accessories factory installed only = versione standard A = High efficiency version L/AL = Low noise version / High efficiency low noise version Attention: For D - T - E version - please contact us

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system requirements.

Configuration Fields:
12 3 4 5 6 7 8 9 10 11 12 | | | | | | | | Code | | Version | Heat recovery | Power supply | Model | | Size Version Evaporator Code: WF Size: 2512, 2812, 3212, 3612, 4212, 4812, 5612, 6412 Model: - Optimised for low condensing temperature Version: - Standard A - High efficiency Version: - Standard L - Low noise Heat recovery: - Without heat recovery D - With partial heat recovery T - With total heat recovery (not available for unit E) Evaporator: - Standard E - Evaporating unit Power supply: - 400V 3~50Hz with fuses 8 - 400V 3~50Hz with circuit breakers 5 - 500V 3~50Hz with fuses (only for sizes 2512 and 2812) 9 - 500V 3~50Hz with circuit breakers (only for sizes 2512 and 2812)

Attention: The standard options are shown by the symbol Example of configuration code: WF2512A8 This is a WF unit, size 2512 in high efficiency version, and with electrical panel and compressor motors at 400V 3~ 50Hz with circuit breakers. Since each option is uniquely identified it is not necessary to indicate the standard options (represented by ) in the unit configurator.

285

Technical data
Mod WF Cooling capacity (E) Total input power (E) Water ow rate evaporator Pressure drop evaporator Water ow rate condenser Pressure drop condenser Input current EER (E) EER class (Eurovent) ESEER Heating capacity Total input power Water ow rate condenser Pressure drop condenser Water ow rate evaporator Pressure drop evaporator Input current COP COP class (Eurovent) Power supply Maximum current (FLA) Startiing current (LRA) Twin-rotor screw compressor Part load (electronic expansion valve) Shell and tube evaporator Evaporator hydraulic connection (victaulic) Shell and tube condenser Condenser hydraulic connection (victaulic) Sound power Sound pressure Mod WF Cooling capacity (E) Total input power (E) Water ow rate evaporator Pressure drop evaporator Water ow rate condenser Pressure drop condenser Input current EER (E) EER class (Eurovent) ESEER Heating capacity Total input power Water ow rate condenser Pressure drop condenser Water ow rate evaporator Pressure drop evaporator Input current COP COP class (Eurovent) Power supply Maximum current (FLA) Startiing current (LRA) Twin-rotor screw compressor Part load (electronic expansion valve) Shell and tube evaporator Evaporator hydraulic connection (victaulic) Shell and tube condenser Condenser hydraulic connection (victaulic) Sound power Sound pressure * Not certified model EUROVENT Cooling: - Evaporator water (in/out) = 12C / 7C - Condenser water (in/out) = 30C / 35C Heating: - Condenser water (in/out) = 40C /45C - Evaporator water (in/out) = 10C / 5C - With condenser isolating valves (mandatory accessory) kW kW l/h kPa l/h kPa A W/W 3612 4212 4812 5612 *6412 984 1111 1276 1406 1546 194,84 219,28 253,97 280,17 309,99 169764 191608 220332 242864 267116 47 43 62 65 75 200810 226576 260529 287309 316136 16 18 24 17 19 317 349 416 457 506 5,05 5,06 5,02 5,02 4,99 A A A A A 6,18 6,19 6,2 6,18 6,16 1060 1195 1374 1515 1668 246.23 277.48 319.33 353.36 390.48 182148 205368 235984 260408 286724 13 14 19 14 15 142442 160596 184676 203545 223978 32 29 43 44 51 406 447 533 585 648 4,31 4,31 4,30 4,29 4,27 B B B B B 400V-3-50Hz 294 336 396 446 494 572 636 702 447 528 596 659 712 872 968 1156 2 2 2 2 2 2 2 2 12.5-100 12.5-100 12.5-100 12.5-100 12.5-100 12.5-100 12.5-100 12.5-100 1 1 1 1 1 1 1 1 6" 6" 6" 8" 8" 8" 8" 8" 2 2 2 2 2 2 2 2 5" 5" 5" 5" 5" 5" 6" 6" 93,6 94 93,5 93,7 94,6 95,5 97,3 97,9 61,6 62 61,5 61,7 62,6 63,5 65,3 65,9 3612A 4212A 4812A 5612A *6412A 1004 1132 1278 1413 1549 188,58 213,76 239,85 269,78 298,99 173204 195564 220504 243724 267288 44 62 42 41 51 202616 228734 257923 285881 313857 69 69 74 74 77 303 332 392 437 483 5,32 5,30 5,33 5,24 5,18 A A A A A 6,66 6,67 6,66 6,54 6,49 1066 1199 1358 1506 1654 237.08 260 300.67 338.30 373.85 182664 206228 232716 258172 283456 56 55 59 59 62 144919 161508 184840 204250 223978 30 42 29 28 35 388 425 501 559 619 4,50 4,50 4,52 4,45 4,43 A A A A A 400V-3-50Hz 294 336 396 446 494 572 636 702 447 528 596 659 712 872 968 1156 2 2 2 2 2 2 2 2 12.5-100 12.5-100 12.5-100 12.5-100 12.5-100 12.5-100 12.5-100 12.5-100 1 1 1 1 1 1 1 1 8" 8" 8" 10" 10" 10" 10" 10" 2 2 2 2 2 2 2 2 4" 4" 5" 5" 5" 5" 6" 6" 93,6 94 93,5 93,7 94,6 95,5 97,3 97,9 61,6 62 61,5 61,7 62,6 63,5 65,3 65,9 2512A 639 120,53 110252 44 129043 63 202 5,30 A 6,63 676 150.92 116272 51 92252 30 258 4,50 A 2812A 725 137,92 125216 59 146621 64 232 5,26 A 6,61 772 171.87 132268 51 104980 40 297 4,49 A 3212A 887 168,89 153252 62 179396 72 268 5,25 A 6,63 944 210.18 161680 58 128346 42 343 4,49 A 2512 630 125,06 108704 41 128639 16 212 5,04 A 6,16 678 158,11 116616 13 91126 28 271 4,29 B 2812 720 143,21 124356 58 147069 16 243 5,03 A 6,19 775 180,80 133300 13 104215 39 312 4,29 B 3212 872 174,00 150500 56 178115 18 282 5,01 A 6,16 940 219.28 161508 14 126214 38 361 4,29 B

kW kW l/h kPa l/h kPa A

A A n % n n dB(A) dB(A) kW kW l/h kPa l/h kPa A W/W

kW kW l/h kPa l/h kPa A

A A n % n n dB(A) dB(A)

Data declared in accordance with UNI EN 14511:2011

(E) EUROVENT for reversible units side water certifies the sun made cold (12-7 C - 30-35 C) Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

286

Technical Data
Mod WF Cooling capacity Total input power Water ow rate evaporator Pressure drop evaporator Input current EER EER class (Eurovent) Power supply Maximum current (FLA) Starting current (LRA) Twin-rotor screw compressor Part load (electronic expansion valve) Shell and tube evaporator Evaporator hydraulic connections (victaulic) Sound power Sound pressure (1) Mod WF Cooling capacity Total input power Water ow rate evaporator Pressure drop evaporator Input current EER EER class (Eurovent) Power supply Maximum current (FLA) Starting current (LRA) Twin-rotor screw compressor Part load (electronic expansion valve) Shell and tube evaporator Evaporator hydraulic connections (victaulic) Sound power Sound pressure (1) kW kW l/h kPa A 2512E 547 143 94084 31 242 3,83 A 294 447 2 35-100 1 6" 93,6 61,6 2512AE 585 143 100620 36 242 4,09 A 294 447 2 35-100 1 8" 93,6 61,6 2812E 624 162 107328 43 277 3,85 A 336 528 2 35-100 1 6" 94 62 2812AE 665 162 114380 49 277 4,1 A 336 528 2 35-100 1 8" 94 62 3212 E 748 195 128656 41 321 3,84 A 396 596 2 35-100 1 6" 93,5 61,5 3212AE 800 195 137600 50 321 4,1 A 396 596 2 35-100 1 8" 93,5 61,5 3612E 4212 E 842 954 221 247 144824 164088 34 31 363 398 3,81 3,86 A A 400V-3-50Hz 446 494 659 712 2 2 35-100 35-100 1 1 8" 8" 93,7 94,6 61,7 62,6 3612AE 4212AE 899 1016 221 248 154628 174752 35 49 363 400 4,07 4,1 A A 400V-3-50Hz 446 494 659 712 2 2 35-100 35-100 1 1 10" 10" 93,7 94,6 61,7 62,6 4812E 1077 279 185244 44 465 3,86 A 572 872 2 35-100 1 8" 95,5 63,5 4812AE 1148 280 197456 34 465 4,1 A 572 872 2 35-100 1 10" 95,5 63,5 5612E 1208 313 207776 47 516 3,86 A 636 968 2 35-100 1 8" 97,3 65,3 5612AE 1246 313 214312 31 518 3,98 A 636 968 2 35-100 1 10" 97,3 65,3 6412E 1328 345 228416 55 571 3,85 A 702 1156 2 35-100 1 8" 97,9 65,9 6412AE 1382 346 237704 40 573 3,99 A 702 1156 2 35-100 1 10" 97,9 65,9

A A n % n dB(A) dB(A)

kW kW l/h kPa A

A A n % n dB(A) dB(A)

(1) Sound pressure measured in free field with directivity factor 2 at 10 m distance, in accordance with ISO 3744. Performance values refers to the following conditions: Cooling: - Evaporator water (in/out) 12C/7C - Condensing temperature 45C

Dimensions (mm)
Mod WF Height (A) Width (B) Length (C) Weight Mod WF Height(A) Width (B) Length (C) Weight mm mm mm Kg 2512 2100 1470 3690 3570 2812 2100 1470 3690 3650 3212 2050 1470 4030 4470 3612 2120 1520 4030 4750 4212 2140 1550 4370 5050 4812 2140 1550 4370 5180 5612 2210 1600 4610 6030 6412 2210 1600 4760 6260

mm mm mm Kg

2512A 2812A 3212A 3612A 4212A 4812A 5612A 6412A 2180 2180 2190 2340 2340 2340 2380 2380 1470 1470 1537 1695 1695 1695 1700 1700 4330 4330 4330 4370 4550 4550 4800 4800 4080 4140 5470 5950 6240 6440 7230 7360

Attention: For the dimensions of versions D - T - L - E contact the head office Code: SWFUY.05 / 1301
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

287

HWF
Aermec participate in the EUROVENT program: LCP / W / P / R up to 1500 kW the products are present on the site www.eurovent-certification.com * Not certified model

Water cooled chillers with twin-rotor screw compressor Cooling capacity from 628 to 1524 kW Heating capacity from 671 to 1615 kW

ENERG
Range Model

IJA IE

IA EFFICIENCY CLASS

ENERG
Range Model

IJA IE

IA EFFICIENCY CLASS

MANUFACTURER
www.eurovent-certification.com

MANUFACTURER
www.eurovent-certification.com

HEAT PUMP LOCAL DESIGNATION LOCAL DESIGNATION Heating mode at full load A B C D E
Rf. : 08-201103

LIQUID CHILLING PACKAGE LOCAL DESIGNATION LOCAL DESIGNATION Cooling mode at full load

A B C D E
Rf. : 08-201103

F G
RS 6/C/003-2011 and RS 6/C/003A-2011

F G
RS 6/C/003-2011 and RS 6/C/003A-2011

OPTIMISED FOR HIGH CONDENSER TEMPERATURES for example: units operating in heating mode STANDARD AND HIGH EFFICIENCY VERSIONS MAXIMUM CONDENSER LEAVING WATER TEMPERATURE: 60C SHELL AND TUBE HEAT EXCHANGERS STANDARD ELECTRONIC EXPANSION VALVE WHICH ALLOWS: - COOLING DOWN TO -6 C - CAPACITY MODULATION 12.5-100%
Characteristics
- Available in 8 sizes - Two independent refrigerant circuits - High efficiency screw compressors optimised for R134a - Heat exchangers with oversized surface areas - Electronic expansion valve as standard - Compact dimensions - Suitable for use in heat pump mode with leaving water temperature up to 60 C (with hydraulic system reversing) and with ground water or geothermal loops. For heating mode operation the IS accessory, condenser isolating valves, is required Operational limits: - condenser leaving water temperature up to 60 C - evaporator leaving liquid temperature down to -6 C Options available: - - - - partial heat recovery total heat recovery evaporating unit low noise unit with compressor acoustical enclosures made from galvanised steel and high density sound absorbent material Modulating capacity control microprocessor system - Redundancy of the unit (one microprocessor per circuit) - Leaving water temperature control with modulating capacity control (12.5-100% for each compressor) and dynamic display of the refrigeration capacity - Condensing control based on pressure with 0-10 Vdc signal for controlling a modulating valve / variable speed pump - Electrical panel with all cables numbered - Current transformer as standard for each compressor - Always Working function. In the case of critical conditions the unit will not stop but automatically adjusts operation - Automatic set point compensation using analogue inputs 4-20 mA or 010 V or an external air sensor - Auto-adaptive differential to ensure correct compressor operating timers - PDC (Pull Down Control) system which prevents capacity loading when the water temperature quickly approaches the set point - DL (Demand Limit) system permits current limiting of the unit during times of insufficient electrical power (load peaks or generator operation) - Multilingual display panel

Accessories
AER485P1: RS-485 interface for supervision remote control max. 6 units in RS485 net- AKW: ACOUSTIC KIT: Allows further unit systems with MODBUS protocol. work; sound reduction using an optimised enclo PRV3: Remote control of the chiller operating AERWEB300-18: Web server to monitor and sure made from a high density ecological functions. remote control max. 18 units in RS485 netmaterial. Only available for L Versions. RIF: Power factor correction. Connected in work; Factory fitted only. parallel to the motor allowing about 10% AERWEB300-6G: Web server to monitor and IS: Condenser isolating valves. Mandatory reduction of input current. Must be requested remote control max. 6 units in RS485 netaccessory for units operating in heat pump at time of order and is available factory fitted work with integrated GPRS modem; mode. only. AERWEB300-18G: Web server to monitor and Factory fitted only. AVX: Spring anti-vibration mounts. remote control max. 18 units in RS485 net AERWEB300: Accessory AERWEB allows work with integrated GPRS modem; remote control of a chiller through a com- MULTICHILLER: Control system for multiple mon PC and an ethernet connection over a parallel installed constant flow chillers procommon browser; 4 versions available: viding individual chiller on/off and control AERWEB300-6: Web server to monitor and capability.

288

Mod AERWEB300 MULTICHILLER AER485P1 PRV3 AVX RIF AKW(WF-L) IS1 IS2 IS3

Accessory compatibility 2512 2812 3212 3612 4212 4812 5612 6412 (x2) (x2) (x2) (x2) (x2) (x2) (x2) (x2) RIFHWF 2512 RIFHWF 2812 RIFHWF 3212 RIFHWF 3612 RIFHWF 4212 RIFHWF 4812 RIFHWF 5602 RIFHWF 6412 /A /A A A A A A A AVX compatibility

Standard/Low noise Mod HWF AVX

2512 673

2812 673

3212 673 3212L 674 3212A 674 3212AL 675

3612 674 3612L 674 3612A 675 3612AL 675

4212 674 4212L 674 4212A 675 4212AL 675

4812 674 4812L 674 4812A 675 4812AL 675

5612 675 5612L 675 5612A 676 5612AL 676

6412 675 6412L 675 6412A 676 6412AL 676

Mod HWF 2512L 2812L AVX 673 673 High efficiency/High efficiency low noise Mod HWF 2512A 2812A AVX 673 673 Mod HWF AVX 2512AL 674 2812AL 674

(x2) Indicate the quantity to be ordered RIF - AKW - IS are accessories factory installed only = Standard version A = High efficiency version L/AL = Low noise version / High efficiency low noise version Attention: For D - T - E versions contact the facory

Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most demanding of system requirements.

Configuration Fields:
123 4 5 6 7 8 9 10 11 12 13 | | | | | | | | Code | | Version | Heat recovery | Power supply | Model | | Size Version Evaporator Code: HWF Size: 2512, 2812, 3212, 3612, 4212, 4812, 5612, 6412 Model: - Optimised for high condensing temperature Version: - Standard A - High efficiency Version: - Standard L - Low noise Heat recovery units: - Without heat recovery D - With partial heat recovery T - With total heat recovery (not available for unit E) Evaporator: - Standard E - Evaporating unit Power supply: - 400V 3~50Hz with fuses 8 - 400V 3~50Hz with circuit breakers 5 - 500V 3~50Hz with fuses (only for sizes 2512 and 2812) 9 - 500V 3~50Hz with circuit switches (only for sizes 2512 and 2812)

Attention: The standard options are shown by the symbol Example of configuration code: HWF2512A8 This is a HWF unit, size 2512 in high efficiency version, and with electrical panel and compressor motors at 400V 3~ 50Hz with circuit breakers. Since each option is uniquely identified it is not necessary to indicate the standard options (represented by ) in the unit configurator.

289

Technical Data
Mod HWF Cooling capacity (E) Total input power (E) Water flow rate evaporator Pressure drop evaporator Water flow rate condenser Pressure drop condenser Input current E.E.R. (E) E.E.R. class (Eurovent) E.S.E.E.R. Heating capacity Total input power Water flow rate condenser Pressure drop condenser Water flow rate evaporator Pressure drop evaporator Input current C.O.P. C.O.P. class (Eurovent) Power supply Maximum current (FLA) Starting current (LRA) Twin-rotor screw compressor Part load (electronic expansion valve) Shell and tube evaporator Evaporator hydraulic connection (victaulic) Shell and tube condenser Condenser hydraulic connection (victaulic) Sound power Sound pressure kW kW l/h kPa l/h kPa A 2512 628 130,1 108360 41 129112 16 226 4,83 B 5,85 671 151.10 115240 13 90893 28 267 4,50 A 370 545 2 12.5-100 1 6" 2 5" 93,6 61,6 2812 713 148,1 123152 56 146682 16 255 4,81 B 5,87 763 172 131064 12 103286 39 300 4,42 A 418 613 2 12.5-100 1 6" 2 5" 94,0 62,0 3212 843 173,6 145512 53 173127 17 286 4,85 B 5,91 899 202.02 154456 13 121939 36 337 4,45 A 468 670 2 12.5-100 1 6" 2 5" 93,5 61,5 3612 4212 946 1092 195,4 225,0 163228 188340 44 41 194437 224288 15 17 314 378 4,84 4,85 B B 5,86 5,87 1010 1164 227.94 262.36 173548 200036 12 14 136783 157715 30 28 371 446 4,43 4,44 A A 400V-3-50Hz 516 612 723 892 2 2 12.5-100 12.5-100 1 1 8" 8" 2 2 5" 5" 93,7 94,6 61,7 62,6 4812 1256 259,6 216892 60 258069 23 426 4,84 B 5,90 1339 302.02 230128 18 181606 41 503 4,44 A 690 995 2 12.5-100 1 8" 2 5" 95,5 63,5 5612 1415 294,3 244412 65 291144 18 488 4,81 B 5,86 1513 343.45 260064 14 204835 45 575 4,41 A 776 1193 2 12.5-100 1 8" 2 6" 97,3 65,3 *6412 1512 314,4 261268 72 311105 18 530 4,81 B 5,88 1616 366.08 277780 14 218956 49 625 4,49 A 846 1340 2 12.5-100 1 8" 2 6" 97,9 65,9

kW kW l/h kPa l/h kPa A

A A n % n n db(A) db(A)

Mod HWF Cooling capacity (E) Total input power (E) Water flow rate evaporator Pressure drop evaporator Water flow rate condenser Pressure drop condenser Input current E.E.R. (E) E.E.R. class (Eurovent) E.S.E.E.R. Heating capacity Total input power Water flow rate condenser Pressure drop condenser Water flow rate evaporator Pressure drop evaporator Input current C.O.P. C.O.P. class (Eurovent) Power supply Maximum current (FLA) Starting current (LRA) Twin-rotor screw compressor Part load (electronic expansion valve) Shell and tube evaporator Evaporator hydraulic connection (victaulic) Shell and tube condenser Condenser hydraulic connection (victaulic) Sound power Sound pressure

kW kW l/h kPa l/h kPa A

kW kW l/h kPa l/h kPa A

2512A 643 128,7 110940 44 131038 65 221 5,00 A 6,19 680 148.93 116616 51 92923 30 261 4,68 A 370 545 2 12.5-100 1 8" 2 4" 93,6 61,6

2812A 730 147,1 126076 60 148952 66 249 4,96 A 6,18 774 169.89 132612 52 105651 41 293 4,67 A 418 613 2 12.5-100 1 8" 2 4" 94,0 62,0

3212A 855 172,1 147576 57 174374 68 278 4,96 A 6,17 902 193 155144 53 121948 39 328 4,56 A 468 670 2 12.5-100 1 8" 2 5" 93,5 61,5

A A n % n n db(A) db(A)

3612A 4212A 966 1108 193,0 222,3 166668 191264 41 59 196897 225905 66 67 306 367 5,01 4,98 A A 6,18 6,19 1022 1172 223.46 256.93 175268 200896 51 52 139647 160046 28 40 361 433 4,58 4,56 A A 400V-3-50Hz 516 612 723 892 2 2 12.5-100 12.5-100 1 1 10" 10" 2 2 5" 5" 93,7 94,6 61,7 62,6

4812A 1249 249,4 215516 40 254569 72 408 5,01 A 6,19 1321 289.20 226526 56 180445 28 481 4,57 A 690 995 2 12.5-100 1 10" 2 5" 95,5 63,5

5612A 1435 287,4 247508 42 292443 77 471 4,99 A 6,17 1519 333.54 260236 60 207131 29 556 4,66 A 776 1193 2 12.5-100 1 10" 2 6" 97,3 65,3

*6412A 1524 306,7 262988 50 310864 76 514 4,97 A 6,16 1615 355.32 276748 59 220212 34 606 4,55 A 846 1340 2 12.5-100 1 10" 2 6" 97,9 65,9

Data declared in accordance with UNI EN 14511:2011 * Not certified model EUROVENT Cooling: - Evaporator water (in/out) = 12C / 7C - Condenser water (in/out) = 30C / 35C Heating: - Condenser water (in/out) = 40C /45C - Evaporator water (in/out) = 10C / 5C - With condenser isolating valves (mandatory accessory)

(E) EUROVENT for reversible units side water certifies the sun made cold (12-7 C - 30-35 C) Sound power: Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. Sound pressure: Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

290

Technical Data
Mod HWF Cooling capacity Total input power Water flow rate evaporator Pressure drop evaporator Input current EER EER class (Eurovent) Electric power supply Maximum current (FLA) Starting current (LRA) Twin-rotor screw compressor Part load (electronic expansion valve) Shell and tube evaporator Evaporator hydraulic connection (victaulic) Sound power Sound pressure (1) kW kW l/h kPa A W/W A A n % n db(A) db(A) 2512E 540 141 92883 30 247 3,83 A 370 545 2 35-100 1 6" 93,6 61,6 2812E 615 161 105773 42 278 3,82 A 418 613 2 35-100 1 6" 94 62,0 3212 E 726 189 124872 39 315 3,84 A 468 670 2 35-100 1 6" 93,5 61,5 3612E 4212 E 816 947 212 246 140352 162884 32 31 345 416 3,85 3,85 A A 400V-3-50Hz 516 612 723 892 2 2 35-100 35-100 1 1 8" 8" 93,7 94,6 61,7 62,6 4812E 1070 278 184040 44 465 3,85 A 690 995 2 35-100 1 8" 95,5 63,5 5612E 1225 318 210700 49 532 3,85 A 776 1193 2 35-100 1 8" 97,3 65,3 6412E 1311 340 225492 54 579 3,86 A 846 1340 2 35-100 1 8" 97,9 65,9

Mod HWF Cooling capacity Total input power Water flow rate evaporator Pressure drop evaporator Input current EER EER class (Eurovent) Electric power supply Maximum current (FLA) Starting current (LRA) Twin-rotor screw compressor Part load (electronic expansion valve) Shell and tube evaporator Evaporator hydraulic connection (victaulic) Sound power Sound pressure (1)

kW kW l/h kPa A W/W A A n % n db(A) db(A)

2512AE 577 143 99244 35 249 4,03 A 370 545 2 35-100 1 8" 93,6 61,6

2812AE 657 162 113004 48 281 4,06 A 418 613 2 35-100 1 8" 94 62,0

3212AE 779 191 133988 47 318 4,08 A 468 670 2 35-100 1 8" 93,5 61,5

3612AE 4212AE 873 1012 214 248 150156 174064 33 49 348 418 4,08 4,08 A A 400V-3-50Hz 516 612 723 892 2 2 35-100 35-100 1 1 10" 10" 93,7 94,6 61,7 62,6

4812AE 1143 280 196596 34 467 4,08 A 690 995 2 35-100 1 10" 95,5 63,5

5612AE 1263 320 217236 32 534 3,95 A 776 1193 2 35-100 1 10" 97,3 65,3

6412AE 1362 342 234264 39 581 3,98 A 846 1340 2 35-100 1 10" 97,9 65,9

(1) Sound pressure measured in free field with directivity factor 2 at 10 m distance, in accordance with ISO 3744. Performance values refers to the following conditions: Cooling: - Evaporator water (in/out) 12C/7C - Condensing temperature 45C

Dimensions (mm)
Mod. HWF Height (A) Width (B) Length (C) Weight Mod. HWF Height (A) Width (B) Length (C) Weight mm mm mm Kg mm mm mm Kg 2512 2100 1470 3690 3570 2812 2100 1470 3690 3650 3212 2050 1470 4030 4470 3612 2120 1520 4030 4750 4212 2140 1550 4370 5100 4812 2140 1550 4370 5200 5612 2210 1600 4610 6110 6412 2210 1600 4760 6310

2512A 2812A 3212A 3612A 4212A 4812A 5612A 6412A 2180 2180 2190 2340 2340 2340 2380 2380 1470 1470 1537 1695 1695 1695 1700 1700 4330 4330 4330 4370 4550 4550 4800 4800 4080 4140 5470 5950 6290 6460 7310 7410

Attention: For the dimensions of versions D - T - L - E contact the head office Code: SHWFUY.01 / 1301
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

291

NCS

Air handling units with 25 mm thick panels. Air flow rate from 1,000 to 45,000 m3/h

Characteristics
The NCS series of air handling units is a direct descendant of the NCD series. They both offer high quality components, versatile configurations, and a complete array of available sections and accessories. The NCS series of air handling units is notable due to its use of 25 mm thick sandwich panels, which are attached to the frame using frame panels which do not require screws. This system allows for uniform pressure on the case, minimizing leakage. Thanks to a modular construction and the wide range of accessories, the designer is always able to select the most appropriate unit for their precise installation type. Main Characteristics Structure: Aluminium sections with rounded edges and reinforced nylon corners. The case is made of sealing sandwich panels, 25 mm thick, attached to the frame using an exclusive frame panel which does not require any screws. Aluminium dampers with aerofoil blades. Precise construction guarantees low leakage. Filter systems All types of filter systems generally used in air handling units are available, all of which guarantee conformance with the current regulations regarding environmental air quality. Humidification systems Chosen based on the specific intended use for the unit, in conformance with the system chosen. Forward or backward curved fan blades. The choice is made based on the requested aeraulic performance, and with attention to output and noise level. Silencers Available in various lengths. Constructed of rock wool, surfaces in contact with the air are protected using polyester film and held inside a micro-perforated galvanized steel sheet.

Heat exchange coils can be removed on slides and are provided in Various types of heat recovery systems various materials based on usage and heating Make it possible to respect current energy saving regulations. system.

Accessories
A vast array of accessories, which can be chosen using our selection programme. The programme also makes it possible to quickly design a unit in real-time.

292

Technical information
NCS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 2 907 1566 1912 2506 3059 3445 4206 4966 6415 7582 9238 11370 13582 17055 20609 24618 29711 2,5 1134 1958 2390 3132 3823 4307 5257 6207 8019 9477 11548 14213 16978 21319 25761 30772 37139 air ow rate (m3/h) 3 1361 2349 2867 3758 4588 5168 6308 7449 9623 11372 13857 17055 20373 25583 30913 36926 44566 3,5 1588 2741 3345 4385 5352 6029 7360 8690 11227 13268 16167 19898 23769 29847 36065 43081 51994

Vel.: Face velocity on the battery pack heat exchange

Dimensional data (mm)


NCS Width 684 1009 1171.5 1009 1171.5 1009 1171.5 1334 1659 1659 1984 1984 2309 1984 1984 2309 2309 External dimensions Height* 521.5 521.5 521.5 684 684 846.5 846.5 846.5 846.5 1009 1009 1171.5 1171.5 1659 1984 1984 2309 Width 613 938 1100.5 938 1100.5 938 1100.5 1263 1588 1588 1913 1913 2238 1913 1913 2238 2238 Internal dimensions Height 409.5 409.5 409.5 572 572 734.5 734.5 734.5 734.5 897 897 1059.5 1059.5 1547 1872 1872 2197

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

*declared external height does not include the base (120 mm)

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

293

Cod.: SNCSUY.00 / 0912

NCD

Air handling units

AERMEC partecipates in the EUROVENT programme for: MB/MB/MECH. Check ongoing validity of certificate online: www.eurovent-certification.com

Features
24 sizes of central air handling units with double panelling with panel thickness of 50 mm Support structure realised in aluminium alloy sections and a large choice of panels. Wide range of sections and components to satisfy all plant engineering requirements Double intake centrifugal fans with forward or reverse blades. PLUG FAN type fan with Inverter regulation, able to adapt to the most varied system requirements. Main Features Structure: In aluminium sections with rounded edges both internally and externally allowing greater cleanliness New panelling and gaskets, able to guarantee reduced seepage in compliance with the EN1886 Standard Reduction of noise emission thanks to the use of material with high sound-absorption power. Small dimensions and contained height. Large availability of filters: Filters with large surfaces to reduce the pressure drops and increase the duration - Cell pre-filters - Roll filters - Bag filters Internal components: - Absolute filters New high-efficiency heat exchangers with - Activated carbon filters small pressure drops - Germicidal lamp Mixing chamber with three dampers The configurations for the mixing chambers New efficient drop eliminator in PVC with three dampers are the following: New heat recoverers with high heat exchange - two upper dampers and an internal one for recirculation; - two front dampers and a horizontal one Electric components for recirculation (for overlapping control Electronic regulation available able to optimiunits); se the performance and simplify installation - two lateral internal dampers and an internal of the control unit itself for recirculation (configuration for expulsion New high performance selection software. and non-ducted fresh air intake)

Accessories
Wide range of accessories among which: - Technical rooms Accessories for air intake/exhaust sections: - flange; - blank panel (to be perforated with care by the customer); - anti-vibration sheet on the intake/flow vents (with or without damper) with earth cable; - aluminium grille (for internal dampers only); - manual command on the dampers; - proportional servo-control; - proportional servo-control with spring return; - pedestrian grill on the floor dampers. Accessories for the fan-motor sections: - Damper on the flow vent; - overpressure damper; - micro switch on the inspection hatch; Accessories common to several sections: - Spot light with window with 24V bulb (the installer must envision the 24V power supply); - manometer with dial; - pressure switch; - instruments-probes holder GJ 1/4" double sleeve; - floor reinforced with non-slip sheet steel.

294

Technical data
NCD 1 NCD 2 NCD 3 NCD 4 NCD 5 NCD 6 NCD 7 NCD 8 NCD 9 NCD 10 NCD 11 NCD 12 NCD 13 NCD 14 NCD 15 NCD 16 NCD 17 NCD 18 NCD 19 NCD 20 NCD 21 NCD 22 NCD 23 NCD 24 Air ow rate m/h 1.134 1.958 2.390 3.132 3.823 4.307 5.257 6.207 8.019 9.477 11.548 14.213 16.978 19.742 25.761 30.772 37.139 47.187 49.235 55.283 61.331 67.379 73.427 79.475 Coil section m2 0,13 0,22 0,27 0,35 0,42 0,48 0,58 0,69 0,89 1,05 1,28 1,58 1,89 2,19 2,86 3,42 4,13 4,8 5,47 6,14 6,81 7,49 8,16 8,83

The performance refers to an air speed through the coils equal to 2.5 m/s.

Dimensional data (mm)

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

295

Cod.: SNCDUY.01 / 0912

NCD 1 NCD 2 NCD 3 NCD 4 NCD 5 NCD 6 NCD 7 NCD 8 NCD 9 NCD 10 NCD 11 NCD 12 NCD 13 NCD 14 NCD 15 NCD 16 NCD 17 NCD 18 NCD 19 NCD 20 NCD 21 NCD 22 NCD 23 NCD 24

Section A 645 645 645 805 805 965 965 965 965 1.130 1.130 1.285 1.285 1.285 2.085 2.085 2.405 2.405 2.405 2.405 2.405 2.405 2.405 2405

Section B 735 1055 1215 1055 1215 1055 1215 1375 1695 1695 2015 2015 2335 2655 2015 2335 2335 2655 2975 3295 3615 3935 4255 4575

NCT H

Air handling units With modular sections

Features
Fan sections, exchange coils, filters and external air intakes: - plug fans for all sizes, in stainless steel or treated material, equipped with guides and supports reduced to a minimum; - coils and heat recovery units in Cu/Cu, waterproof Cu/Cu, stainless steel/Cu or stainless steel/ stainless steel; - class F7 filters positioned upstream and on the pick-up points of the unit, class F8/F9 downstream (possibility to equip the unit with filters with a germicidal capacity); - external air intakes scaled for speeds of less than 2m/s, and equipped with suitable protective means. Humidification, silencers, drop eliminators: - steam humidification, either direct or with a producer operating with immersed electrodes; - suitable distances are maintained between the humidification and the subsequent component; - drop eliminators subjected to antibacterial treatment or made of stainless steel. Performance and safety characteristics: - the unit performance levels are certified according to the Eurovent programme; - the unit is supplied complete with all the electrical and electronic components for correct operation, and therefore carries the EC mark showing that it satisfies the safety requisites of the relevant directives. Inspection and cleaning: - access openings, drainage panels and adequate lighting in every section; - curved inner corners to avoid the accumulation of dirt; - edges and slits have been avoided and all permanent joints are sealed; - the drainage outlets are fitted with easy-toinspect drain-taps. Panelling and inner surface: - the precise frame-panelling coupling allows you to reach casing air seepage values that fall within class B of Standard UNI EN 1886, with the certification of the TV laboratories; - the materials used offer a good resistance to cracking, splintering, flaking and abrasion, they can be washed and disinfected, and they do not favour the proliferation of biological agents or agents that encourage bioburden reduction (antibacterial treatment with certified bioburden reduction).

296

Technical data
Air ow rate m3/h 1800 2520 3130 3820 4500 5080 6230 7340 9470 10730 13860 17500 21300 25780 30780 Coil section m2 0,202 0,278 0,348 0,425 0,502 0,566 0,69 0,815 1,053 1,191 1,539 1,944 2,369 2,862 3,419

NCT H 2 NCT H 3 NCT H 4 NCT H 5 NCT H 6 NCT H 7 NCT H 8 NCT H 9 NCT H 10 NCT H 11 NCT H 12 NCT H 13 NCT H 14 NCT H 15 NCT H 16

The performance levels refer to an air speed through the coils equal to 2.5 m/s.

Dimensions (mm)

NCT H 2 NCT H 3 NCT H 4 NCT H 5 NCT H 6 NCT H 7 NCT H 8 NCT H 9 NCT H 10 NCT H 11 NCT H 12 NCT H 13 NCT H 14 NCT H 15 NCT H 16

Section A 805 805 805 805 805 1125 1125 1125 1125 1445 1445 1765 1765 2085 2085

Section B 735 895 1055 1215 1375 1055 1215 1375 1695 1375 1695 1695 2015 2015 2335 Cod.: SNCTHUY.01 / 1009

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

297

NEW

SPL 025/130
R410A

Swimming Pool Lines Air handling unit high efficiency for health centres. Air flow from 4,000 to 13,000 m3/h.

TECHNOLOGY

HIGH EFFICIENCY

The units from the SPL series represent the ideal solution to guarantee the comfort conditions in small-medium spaces such as health centres, spa areas, tness centres, small swimming pools, sports facilities, etc. The unit contains a refrigerant circuit and a system for the recovery of sensible and latent heat coming from the humid air extracted from the space, thereby being optimised for the reduction of energy consumption. The main function of the unit, which is a "plug and play" machine ready for use, is that of dehumidifying and at the same time ensuring control of the temperature and humidity conditions of the area served. The unit is tted with an efcient heat recovery system on the water side, to be used to partially heat the swimming pool water at no cost. The structure and all the internal components are built to ensure the maximum resistance to corrosion.

Characteristics
VERSIONS 7 sizes available. REFRIGERANT CIRCUIT: valve (standard); this allows the accurate con Fitted with scroll compressor supplied with trol of the supply air temperature. The frame rubber anti-vibration feet, refrigerant gas/air of the coil is in painted galvanised steel to heat exchanger coil with copper tubes and preensure the maximum resistance to corrosion. painted aluminium fins and painted frame, filter, electronic expansion valve, liquid receiver, ELECTRICAL PANEL: filter drier, controls (pressure transducers and Power and controls panel unit mounted. visual indicators) and safeties (high and low Electrical installation for the connection of pressure pressostats), brazed copper connecpower and controls, set in tubes or conduits tions, refrigerant charge of environmentally with glands and grommets, IP44 protective friendly R410A. The refrigerant circuit is rating. Remote panel supplied as standard for installed in a compartment isolated from the the control of all the main functions and disair flow to facilitate checks and maintenance. play of alarms.

STRUCTURE: Anodised aluminium profile with reinforced nylon corner pieces. Casing made from sandwich type panels (50mm thickness), with internal surface pre-painted galvanised steel, external in pre-painted galvanised steel and insulating material hot injected polyurethane with a density of 42 kg/m, fixed without screws but with panel locking profiles, doors with keyless handles. This fixing method allows a uniform pressure on the casing, ensuring an excellent resistance to the leakFAN SECTIONS: age of air and water. The support structures Treated with epoxy paint resistant to corroand the seals around components are comsion, fitted with "plug fans" with backward pletely painted to ensure the maximum corrocurved impeller of high output. Electrical sion resistance. The bottom surfaces of the motor directly coupled to the impeller suitaunit are fitted with drain panels in pre-painted ble for inverter control (standard). galvanised steel with a central drain point piped sideways. FILTRATION SYSTEMS: Fitted as standard with panel filters in extract THERMAL RECOVERY SECTION: (G4 efficiency class according to EN779) and High efficiency static cross flow in pre-paintpanel + bag filters (G4 + F9 efficiency class ed aluminium. Including dampers: recirculataccording to EN779) meet the requirements ing damper used for the quick start up of the for the applicable standards for indoor air space, recirculating damper for the "primary" quality. Dirty filter differential pressure cycle, dampers on the air inlet and extract. switches are provided as standard. All dampers are manufactured in anodised aluminium and are individually controlled by HOT WATER HEATING COIL: an external actuator for precise air flow con With copper tubes and pre-painted aluminitrol. um fins to heat the supply air after dehumidification, controlled by a modulating 3 way

298

Operating schematics

The principal operation modes of the unit are shown in the example schematics below. In all the following schematics the hot water coil is always operating because the external air temperature is below 10C with a required supply air temperature to compensate for the heat losses from the building. "Start up" cycle
The operating mode is with no external air ow. The whole air ow is recirculated through damper 5 and returned to the pool area. The hot water coil is operational. The "start up cycle" is activated for the time necessary to heat up the area.

Supply

"Dehumidication" cycle
Dehumidication with external air
Extract External air External air External air

External air
6 2 1

Extract

5 4 3

The operating mode is with external air dehumidifying the space, compensating for evaporation from the pool. The refrigerant circuit (consisting of the compressor 1 and the coils 2 and 3) allows the sensible and latent heat recovery of the extracted air to be transferred to the supply air or the water, through the thermal heat exchange consisting of the double heat exchanger on the water side. The hot water coil 4 supplements, if necessary, the heating capacity provided by the refrigerant circuit, placed downstream of the entering air ow (condensing coil 3).

Supply

Dehumidication with external air and primary cycle

6 5 4 3 2

When required the compressor also assists in the dehumidication of the pool area. The supply air ow is modulated by the fan inverter to reach the required hygrometric conditions. As a function of the external ambient temperature the unit modies the operating mode to achieve the best efciency possible.

Supply

Extract

Dehumidication with external air (night cycle)


Extract

6 5 4 3 1 2

In night time mode the unit modies the operating settings to adapt to the changes of evaporation from the pool and reduce consumption to the minimum.

Supply

299

Technical data

SPL Nominal airow (supply/extract) Available pressure (supply/extract) Heat recovery capacity recovered1 Max heat recovery efciency1 Refrigerant circuit recovered capacity1 Total recovered capacity1 Compressor power input1 COP1 COP2 Total dehumidication capacity1 Supply fan power input Extract fan power input Type / number of compressors Hot water heating coil (standard) Capacity (without recovery active)1 Water ow rate 3 Water pressure drop 3 Water ow rate nominal4 Pressure drop4 Water ow rate nominal pool5 Pressure drop pool side5 Pressure drop intermediate circuit side5 Electrical data Unit power supply Maximum total current input supply fan Maximum total current input extract fan Unit maximum current input Unit starting current A kW l/h kPa m3/h Pa kW % kW kW kW kg/h kW kW n

025 2.500 400 7,9 80,8 7,5 15,4 1,3 11,8 3,9 15,5 1,6 1,2

040 4.000 400 12,6 79,3 10,5 23,1 1,6 14,4 4,0 25,2 2,6 1,9

060 6.300 400 20,4 80,1 21,3 41,6 3,7 11,2 4,1 40,1 3,7 2,7 Scroll / 1

100 10.000 400 32,0 79,5 31,7 63,7 6,0 10,6 4,0 63,7 5,9 4,5

130 13.000 400 41,5 79,4 45,7 87,3 8,4 10,4 4,1 82,7 7,6 5,7

26,1 2.250 23,5

35,4 3.050 43,7

61,6 5.300 33,1

95,3 8.200 48,8

124,5 10.700 46,3

Plate heat exchanger R410A/non aggressive water (standard) l/h kPa 950 19 1.120 19 2.500 31 3.600 32 5.400 33

Plate heat exchanger accessible non aggressive water/pool water (standard) l/h kPa kPa 1.200 32,4 21,2 1.400 34 22,3 3.100 31,4 20,6 4.500 33 21,6 6.800 34,5 22,5

400 V - 3 ph - 50 Hz 3,5 6,2 11 14,6 15

A A A

2,6 11,6 32,1

4,9 17,1 46,1

6,4 32,4 91,4

11,3 49,3 181,9

11,3 61,3 184,3

1 2 3 4 5

External air 0C,80% RH; internal air 29C,60% RH. Values as per conditions of D.M. 7 april 2008 for heating only operation. Water temperature inlet/outlet 70/60C; water pressure drop including 3 way valve. Water temperature inlet/outlet non aggressive 27/37C. Water temperature inlet/outlet intermediate circuit 37/27C; water temperature inlet/outlet pool 25/35C Preliminary technical data, subject to modification.

300

Dimensional data (mm)

B SPL Height (including base H=120mm) Width Length Weight A B C mm mm mm kg 025 1.765 895 3.230 900 040 1.765 895 3.390 1.000 060 2.245 1.055 4.190 1.350 100 2.405 1.375 4.190 2.060 130 2.405 1.695 4.670 2.600

Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data .

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

301

Cod.: SSPL025_130UY.00 / 1301

NEW

SPL 160/250
R410A
TECHNOLOGY

Swimming Pool Lines Air handling unit high efficiency for health centres. Air flow from 16,000 to 25,000 m3/h.

HIGH EFFICIENCY

The units from the SPL series represent the ideal solution to guarantee the comfort conditions in medium-large spaces such as health centres, spa areas, tness centres, swimming pools, sports facilities, etc. The unit contains a refrigerant circuit and a system for the recovery of sensible and latent heat coming from the humid air extracted from the space, thereby being optimised for the reduction of energy consumption. The main function of the unit, which is a "plug and play" machine ready for use, is that of dehumidifying and at the same time ensuring control of the temperature and humidity conditions of the area served. The unit is tted with an efcient heat recovery system on the water side, to be used to partially heat the swimming pool water at no cost. The structure and all the internal components are built to ensure the maximum resistance to corrosion.

Characteristics
VERSIONS 3 sizes available. REFRIGERANT CIRCUIT: supply air after dehumidification, controlled by a modulating 3 way valve (standard); this Fitted with scroll compressor supplied with allows the accurate control of the supply air rubber anti-vibration feet, refrigerant gas/air STRUCTURE: temperature. The frame of the coil is in paintheat exchanger coil with copper tubes and pre Anodised aluminium profile with reinforced ed galvanised steel to ensure the maximum painted aluminium fins and painted frame, filnylon corner pieces. Casing made from sandresistance to corrosion. ter, electronic expansion valve, liquid receiver, wich type panels (50mm thickness), with filter drier, controls (pressure transducers and internal surface pre-painted galvanised steel, ELECTRICAL PANEL: visual indicators) and safeties (high and low external in pre-painted galvanised steel and Power and controls panel unit mounted. pressure pressostats), brazed copper connecinsulating material hot injected polyurethane Electrical installation for the connection of tions, refrigerant charge of environmentally with a density of 42 kg/m, fixed without power and controls, set in tubes or conduits friendly R410A. The refrigerant circuit is screws but with panel locking profiles, doors with glands and grommets, IP44 protective installed in a compartment isolated from the with keyless handles. This fixing method rating. Remote panel supplied as standard for air flow to facilitate checks and maintenance. allows a uniform pressure on the casing, the control of all the main functions and disensuring an excellent resistance to the leakplay of alarms. FAN SECTIONS: age of air and water. The support structures Treated with epoxy paint resistant to corroand the seals around components are comsion, fitted with "plug fans" with backward pletely painted to ensure the maximum corrocurved impeller of high output. Electrical sion resistance. The bottom surfaces of the motor directly coupled to the impeller suitaunit are fitted with drain panels in pre-painted ble for inverter control (standard). galvanised steel with a central drain point piped sideways. FILTRATION SYSTEMS: Fitted as standard with panel filters in extract THERMAL RECOVERY SECTION: (G4 efficiency class according to EN779) and High efficiency static cross flow double plate panel + bag filters (G4 + F9 efficiency class heat exchanger in pre-painted aluminium. Including dampers: recirculating damper used according to EN779) meet the requirements for for the quick start up of the space, recirculatthe applicable standards for indoor air quality. ing damper for the "primary" cycle, dampers Dirty filter differential pressure switches are on the air inlet and extract. All dampers are provided as standard. manufactured in anodised aluminium and are individually controlled by an external actuaHOT WATER HEATING COIL: tor for precise air flow control. Water coil with copper tubes and pre-painted aluminium fins and painted frame to heat the

302

Operating schematics

The principal operation modes of the unit are shown in the example schematics below. In all the following schematics the hot water coil is always operating because the external air temperature is below 10C with a required supply air temperature to compensate for the heat losses from the building.

"Start up" cycle


Top view
The operating mode is with no external air ow. The whole air ow is recirculated through damper 5 and returned to the pool area. The hot water coil is operational. The "start up cycle" is activated for the time necessary to heat up the area
Extract External air
2 6 1

Supply

"Dehumidication" cycle
Dehumidication with external air Top view
Extract External air External air External air

Supply

4 3

The operating mode is with external air dehumidifying the space, compensating for evaporation from the pool. The refrigerant circuit (consisting of the compressor 1 and the coils 2 and 3) allows the sensible and latent heat recovery of the extracted air to be transferred to the supply air or the water, through the thermal heat exchange consisting of the double heat exchanger on the water side. The hot water coil 4 supplements, if necessary, the heating capacity provided by the refrigerant circuit, placed downstream of the entering air ow (condensing coil 3).

Dehumidication with external air and primary cycle Top view


Extract
2

Supply

5 1

4 3

When required the compressor also assists in the dehumidication of the pool area. The supply air ow is modulated by the fan inverter to reach the required hygrometric conditions. As a function of the external ambient temperature the unit modies the operating mode to achieve the best efciency possible.

Dehumidication with external air (night cycle) Top view


Extract
2

Supply

5 1

In night time mode the unit modies the operating settings to adapt to the changes of evaporation from the pool and reduce consumption to the minimum.

4 3

303

Technical data

SPL Nominal airow (supply/extract) Available pressure (supply/extract) Heat recovery capacity recovered1 Max heat recovery efciency1 Refrigerant circuit recovered capacity1 Total recovered capacity1 Compressor power input1 COP1 COP2 Total dehumidication capacity1 Supply fans power input Extract fans power input Type / number of compressors Hot water heating coil (standard) Capacity (without recovery active)1 Water ow rate 3 Water pressure drop 3 Water ow rate nominal4 Pressure drop4 Water ow rate nominal pool5 Pressure drop pool side5 Pressure drop intermediate circuit side5 Electrical data Unit power supply Maximum total current input supply fans Maximum total current input extract fans Unit maximum current input Unit starting current A kW l/h kPa m3/h Pa kW % kW kW kW kg/h kW kW n

160 16.000 400 59,6 93 46,3 105,9 8,5 12,5 4,0 102,2 10,9 8,3

200 20.000 400 68,6 86 53,6 122,2 9,2 13,3 3,9 127,6 13,7 9,8 Scroll / 1

250 25.000 400 89,2 89 69,4 158,6 12,8 12,4 3,9 159,5 17,7 12,4

131,9 11.300 43,7

182,7 15.700 37,9

205,9 17.700 42,2

Plate heat exchanger R410A/non aggressive water (standard) l/h kPa 5.760 33 6.450 33 8.260 33

Plate heat exchanger accessible non aggressive water/pool water (standard) l/h kPa kPa 7.200 34,2 22,3 8.100 34,7 22,7 10.400 34,2 22,2

400 V - 3 ph - 50 Hz 29,2 41 42

A A A

22 86,2 209

22,6 99,6 223

30 123 287

1 External air 0C,80% RH; internal air 29C,60% RH. 2 Values as per conditions of D.M. 7 april 2008 for heating only operation. 3 Water temperature inlet/outlet 70/60C; water pressure drop including 3 way valve. 4 Water temperature inlet/outlet non aggressive 27/37C.

Water temperature inlet/outlet intermediate circuit 37/27C; water temperature inlet/outlet pool 25/35C Preliminary technical data, subject to modication.

304

Dimensional data (mm)

SPL Height Width Length Weight A B C mm mm mm kg

160 2.085 2.015 5.790 2.780

200 2.405 2.175 5.790 3.250

250 2.405 2.335 6.430 3.580

Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data .

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

305

Cod.: SPL160_250UY.00 / 1301

NEW

ENERGY
R410A
TECHNOLOGY

Air handling unit for outside air with high energy efficiency. Airflow from 4,000 to 25,000 m3/h.

HIGH EFFICIENCY

The units of the Energy series represent the maximum expression of technical innovation for the treatment of outside air. The Energy series has been specically designed to reduce to the minimum the operating energy consumption, which represents around 80% of the entire life cycle cost of an air treatment unit. The double heat recovery system (static and active) and the innovative cooling and adiabatic humidication system, allow the supply of air at the desired conditions with the minimum energy expenditure. The damper for total bypass allows free-cooling in the intermediate season, exploiting to the maximum the free external thermal contribution. The Energy series is manufactured in full compliance with the standard EN1886 with regards to mechanical resistance, air leakage, thermal and acoustical insulation of the casing.

Characteristics
VERSIONS 5 sizes available. and bag), to satisfy any filtration requirement and ensure compliance with the current air quality standards. Dirty filter pressure switches supplied as standard. ensure the continuous drainage of water and avoid stagnation. ELECTRICAL PANEL: Complete with power and controls unit mounted. Remote panel for the control of all the main functions and display of alarms. MICROPROCESSOR CONTROLLER: Capable of controlling the various operating modes (control of outside air, control of total air), ensuring the maximum energy saving in each operating condition. RS485 interface supplied as standard (MODBUS protocol) for connection to a supervisory systems and remote control. Manual season change over (summer/winter). ON DEMAND: Hot water re-heat coil (only Standard version, as standard on Eco version), enthalpy freecooling (available only with ambient temperature control), bag filters.

PLUG AND PLAY: The units of the Energy series are delivered ready for use. In particular, the machine is STATIC HEAT RECOVERY: equipped with a complete control system and Integrated reversible heat pump. Tandem the refrigerant circuit is completely assembled scroll compressor (single for sizes 040 and and tested, minimising the time and cost of 060) supplied with rubber anti-vibration feet; installation and start up. continuous capacity control through an inverter to ensure the maximum energy savSTRUCTURAL ASSEMBLY: ings even at part load. Double expansion In aluminium profile with rounded edges and valve electronically controlled. 4 way refrigreinforced nylon corner pieces. The casing is erant cycle reversing valve. Coils manufacmanufactured from sandwich panels of 50 tured with copper tubes and prepainted alumm thickness, fixed to the frame with an minium fins. Environmentally friendly exclusive panel fixing without the use of refrigerant R410A ensures improved energy screws. This fixing method allows a uniform efficiency for the refrigerant cycle. pressure on the casing, ensuring an excellent resistance to the leakage of air and water. RE-HEAT COIL: Water in the Standard version (optional) and MODULATING BYPASS DAMPER: Eco version (standard), hot gas in the Dry ver In aluminium with opposed aerofoil blades, sion (standard). installed in the extract air flow to permit freecooling. Additional recirculating damper (only COOLING SYSTEM: in the Eco version). The accurate manufactur Adiabatic with water spray in the extract air, ing minimises air leakage. with self cleaning spray nozzles and high pressure pump module, having the function PLUG FANS: of maximising the heat exchange in the dou Very high efficiency directly coupled to the ble heat recovery system. motor. Inverter for continuous control of supply and extract air flow. WATER HUMIDIFICATION SYSTEM: Spray in the supply air. FILTRATION SYSTEMS: Lower surfaces of the unit equipped with Various types of filters are available (panel drain panels with central condensate drain to

306

Refrigerant circuit with inverter compressor

Modulating dampers for free-cooling

Humidication system pump

Fan inverter

Re-heater coil (optional)

Electrical panel with power and controls

Double static heat recovery

VERSION ENERGY STD ENERGY DRY ENERGY ECO

Adiabatic cooling / humidication

Recirculating damper -

Hot gas re-heat -

Water re-heat Optional -

307

Technical data

Energy Air ow nominal Air ow minimum Max motor capacity standard fans Current input at max capacity Available supply static pressure Available extract static pressure Max motor capacity oversized fans Available supply pressure Available extract pressure Recovered heat capacity1, 3 Heat recovery output1, 3 Cooling capacity heat recovery circuit active 1 Compressor power input 1 Compressor current input 1 E.E.R. total 1 Recovered heat capacity2, 3 Heat recovery output2, 3 Heating capacity heat recovery circuit active 2 Compressor power input 2 Compressor current input 2 C.O.P. total 2 Type compressors/ number Power supply Pump capacity adiabatic cooling circuit Humidication capacity Water ow rate Heating capacity water coil 4 Water ow rate Pressure drop water side Pressure drop air side kW g/kg kg/h kW m3/h kPa Pa kW % kW kW A m3/h m3/h kW A Pa Pa kW Pa Pa kW % kW kW A

040 4.000 2.800 2,2 4 300 200 3 500 400 16,2 75,4 19,1 7,3 13,8 3,5 12,5 76,6 24,2 7,4 15,9 3,9 Scroll / 1

060 6.000 4.200 3 5,4 300 200 4 500 400 23,4 72,3 27,8 9,4 13,2 3,8 21,9 74 32,1 8,0 11,3 4,5

100 10.000 7.000 5,5 9,9 300 200 7,5 500 400 38 71,3 45,6 15,3 24,12 3,8 35,6 72,1 56,8 17,8 29,1 3,9

160 16.000 11.200 7,5 13,5 300 200 11 500 400 63,3 74,0 73,8 22 32,5 4,1 59,2 74,8 84,6 19,1 29,2 4,7 Scroll / 2

250 25.000 17.500 15 27,1 300 200 15 500 400 100,8 75,4 97,6 25 37 4,4 94,2 76,2 109,8 22,6 34,7 4,8

400V / 3Ph+N / 50Hz 0,46 5 24 25,4 1,09 8 28 0,46 5 36 33,9 1,50 6 41 0,46 5 60 60,7 2,60 9 33 0,69 5 96 102,0 4,38 8 52 0,69 5 150 133,6 5,87 7 80

1 2

External air 35C, 40% RH; extract air 27C, 47,5% RH, adiabatic cooling active. External air 7C, 87% RH; extract air 20C, 60% RH, adiabatic humidication active.

3 4

Constant performance over time. Water inlet 70C, water outlet 50C. Preliminary technical data, subject to modication.

308

Dimensional data (mm)

040 Height Width Length Weight Standard version mm mm mm kg 1.810 1.055 4.830 1.400

060 1.810 1.375 4.830 1.800

100 2.130 1.695 5.630 2.300

160 2.450 2.015 6.270 2.900

250 2.450 2.335 6.270 3.500

Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data .

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

309

Cod.: SENERGYUY.00 / 1301

RTE

ROOF-TOP cooling only and heat pump unit Cooling capacities from 11,3 up to 55,9 kW Heating capacities from 11,5 up to 55,70 kW

Features
The RTE rooftop units represent the ideal solution for air conditioning medium-small applications for tertiary and commercial use. The units offer noteworthy advantages in terms of air quality and environmental comfort, easy installation and low noise level. The availability of many accessories also confers great versatility, thus making the range perfectly suitable for the varied system requirements. They are reversible air-cooled, used in winter and summer, scroll compressors with R410A refrigerant fluid. Handling section fans: for sizes 025, 030, 040, 050, the fans are the centrifugal double intake type directly coupled with the electronic device for variation of the number of revs as per standard. For sizes 080, 090, 100, 150, 200 the fans are the double intake centrifugal type coupled using belts and pulleys with variable pitch. with copper pipes and high efficiency aluminium louvers. Air filtering using synthetic pleated filters with G4 efficiency (EN779). Microprocessor adjustment complete with electric control board, probes and actuators for all components. models available RTE F Cooling only version.

The direction of delivery air flow can be: RTE 020...050 - Rear RTE H Structure: RTE 080...200 Heat pump version. For 025, 030, 040, 050 sizes it is self-supporting - Rear / lower / upper with simple aluminium alloy panelling with isolation of the air handling section via closed Helical condensation section fans: cell expanded polyethylene (density 30 kg/m3). statically and dynamically balanced helical For 080, 090, 100, 150, 200 sizes it is self- type, protected electrically by magnet circuit suppo rting with in te r na l a nd e x t e r na l breakers and mechanically by grids. aluminium alloy sandwich-type panelling with thickness of 25 mm and injected polyurethane Cooling circuit: insulation (density 42 kg/m3) for the perimeter Fitted with scroll compressors that guarantee panels and for the roof of the air handling low noise level and high efficiency thanks to the section. use of R410A gas, internal and external coil

310

Accessories
SM - Mixing chamber 2 dampers. BRE - Electric coils. Including damper servocontrols and rain-proof Electric coil. See the table below. hoods. TP - Pressure transducers. SM3P - Mixing chamber 3 dampers. As per standard on all heat pump models. 3-damper mixing chamber with return fan and rear intake, including damper servocontrols, rain-proof DCPR - PRESSURE CONTROL device. hoods and management of the free-cooling for tem- Extends the functioning range of the rooftop in the perature. summer cycle (minimum temperature of the external air up to 10 C) and in the winter cycle in heat pump SM3I - Mixing chamber 3 dampers. mode (maximum temperature of the external air up to 3-damper mixing chamber with return fan and lower 25 C). Moreover, it makes functioning silent with intake, including damper servocontrols, rain-proof partial loads. A regulation circuit board varies the hoods and management of the free-cooling for tem- number of the motor condensing fan revs on the basis perature. of the condensation pressure, read by the relevant transducers, thus guaranteeing correct power supply SCSM - Mixing chamber 2 dampers. of the thermostatic valve. Including servocontrols with dampers spring return and rain-proof hoods. DP - dehumidification and post-heating kit. Kit for management of dehumidification and postSCSM3P - Mixing chamber 3 dampers. heating. It can be coupled with the PUC accessory 3-damper mixing chamber with return fan and rear (Humidification contact). intake, including spring return servocontrols, dampers, rain-proof hoods and management of the free- FCH - enthalpy freecooling. cooling for temperature. Only for models from 100 to 200 and the 3-damper mixing chamber, if present. SCSM3I - Mixing chamber 3 dampers. It can be coupled with: 3-damper mixing chamber with return fan and lower - the DP accessory (dehumidification and post-heaintake, including spring return servocontrols, dam- ting management kit) only in presence of the 3-shutpers, rain-proof hoods and management of the free- ter mixing chamber and water or electric coil. cooling for temperature. - the PUC accessory (Humidification contact) only with 3-damper mixing chamber. P - filters pressure switch. puc - humidification contact Only for 100, 150, 200 models. BRT2 - 2 row water coils . ON/OFF contact (normally open) for humidification Water coils for two row heating. consent. In this case, the unit is complete with one humidity probe positioned in the environment air BRT3 - 3 row water coils return. A humidity probe is also supplied to be posiWater coil for three row post-heating. tioned downstream from the humidification section.
Mod. SM SM3P SM3I SCSM SCSM3P SCSM3I PF BRT2 BRT3 BRE103 (4) BRE106 BRE109 BRE107 BRE112 BRE118 BRE212 BRE218 BRE224 BRE236 TP DCPR DP DP+FCH (1) PUC+FCH (2) PUC+DP (3) FCH PUC SQA PR2 GP VT AVX RC 25 30 40 50 80 90

sqa Air quality probe. Only for 100, 200 models. PR2 - REMOTE panel. Allows to control the rooftop at a distance. GP - protection grid. Protects the external coil from blows and to prevents access to the underlying area where the compressors and the chiller circuit are housed. VT - Rubber anti-vibration mounts. Rubber anti-vibration mounts. Select the VT model from the compatibility table. AVX - Spring anti-vibration mounts. Spring anti-vibration mounts. Select the AVX model from the compatibility table. RC Roof-curb. Only for models from 080 to 200. Attention: The standard configuration control is however able to manage the following accessories, which can also be added at a later date, SM, PF, SSV (supervisor), PR2, TP. For any other accessory, change the electric control board. Independently from the type of control, GP , VT, AVX, RC can be supplied at a later date.

100

150

200

(1) Only if 3-damper mixing chamber and water or electric coil present. (2) Only with 3-damper mixing chamber. (3) Only if electric or water coil present. (4) BRE103 = electric coils, the first indicates the stages, the last two characters indicate the power (e.g.: 1 stage, 3 kW).

311

Technical data
RTE F Cooling capacity Sensitive nominal cooling capacity Compressor input power EER RTE H Cooling capacity Sensitive nominal cooling capacity Compressor input power EER Heating capacity Compressor input power COP 25 11,3 6,8 2,4 4,71 25 11,1 6,7 2,4 4,63 11,5 2,3 5,00 1.500 1.275 1.725 1 1 1 1 30 13,2 8,2 2,9 4,55 30 13,2 8,2 3 4,40 12,5 2,3 5,43 1.900 1.615 2.185 1 1 1 1 40 17,2 10,3 3,2 5,38 40 16,7 10,2 3,3 5,06 17,1 3,1 5,52 2.400 2.040 2.760 1 1 1 1 50 20,9 12,4 3,8 5,50 50 20,3 12,2 4 5,08 19,3 3,3 5,85 2.900 2.465 3.400 1 1 1 1 80 25,5 15,7 5,4 4,72 80 25,1 15,5 5,4 4,65 25,3 4,6 5,50 4.000 3.400 4.600 Scroll 1 1 Axial 1 2 G4 50 1 350 36,1 52,1
6/12/18

kW kW kW W/W

90 29,7 18,8 6,2 4,79 90 29,5 18,7 6,2 4,76 29,1 5,6 5,20 4.500 3.825 5.175 1 1 1 2

100 39,7 24 8,1 4,90 100 39,4 23,8 8,1 4,86 39,1 6,9 5,67 6.000 5.100 6.900 1 1 4 2

150 48,8 29,6 10,7 4,56 150 48,3 29,4 10,7 4,51 48,6 8,8 5,52 8.000 6.800 9.200 1 1 4 2

200 55,9 32,8 11,8 4,74 200 55,5 32,5 11,80 4,70 55,70 10,40 5,36 9.000 7.650 10.350 1 1 4 2

kW kW kW W/W kW kW W/W

Nominal air ow rate internal fans m3/h Minimum air ow for the handling section m3/h Maximum air ow for the handling section m3/h type Compressors n Cooling circuits n Fans type External fans n Internal fans n Air lters type Thickness mm Evaporator type Maximum available pressure Pa Water coil heating capacity * Electric coil heating capacity Sound pressure level Electrical power supply V/Ph/Hz kW kW dB(A)

315 16,3 22,5


3/6/9

275 19,2 27
3/6/9

345 22,5 32,2


3/6/9

287 25,5 37,1


6/12/18

330 39 56,8 64

365 57 81,8 67

360 68,9 100,4 67

330 74,4 109,3 67

12/18/24/36 12/18/24/36 12/18/24/36 12/18/24/36

58

58

61

61

64 400/3+N/50

* Room air 20C d.b., water 80/70C. Cooling capacity RH 50% (Twb 19C), Text 35C RH 50%; Operation with 30% of ambient air and expelled (version with mixing chamber with three dampers SM3). Nominal air ow. Heating capacity Heating capacity Tin 20C RH 50%, Text 7C RH 70%. Operation with 30% of ambient air and expelled (version with mixing chamber with three dampers SM3). Nominal air ow. Sound pressure: Sound pressure in free eld, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

312

Dimensional data (mm)

025 - 030

040 - 050

080 - 200

RTE Height Width Depth RTE F weight RTE H weight

A B C

mm mm mm kg kg

25 1.040 1.175 1.155 235 245

30 1.040 1.175 1.155 250 260

40 1.040 1.175 1.155 270 280

50 1.040 1.175 1.155 285 300

80 1.175 1.240 1.805 435 455

90 1.175 1.240 1.805 450 470

100 1.500 1.510 2.710 650 690

150 1.500 1.510 2.710 675 710

200 1.500 1.510 2.710 735 770

Dimensions and weights of the basic set-up unit.

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

313

Code : SRTE025_200UY.02 /1301

RTE
R410A

ROOF-TOP cooling only and heat pump unit Cooling capacities from 82,5 up to 152 kW standard version Heating capacities from 77,5 up to 148 kW standard version

Features
The rooftop units in the RTE range represent the ideal solution for air conditioning environments with average cubage for tertiary, commercial and industrial destination. The units offer noteworthy advantages in terms of air quality and environmental comfort, easy installation and low noise level. The use of ecological R410A fluid refrigerant allows to increase the unit efficiency. The availability of many accessories, e.g. the cross flow recovery systems or the hot air generator with condensation, also confer a noteworthy versatility, making the RTE range perfectly suitable for the various system requirements. Structure: Self-supporting with external aluminium alloy and internal galvanised steel sandwich-type panelling with thickness of 50 mm and injected polyurethane insulation (density 42 kg/m3) for the air handling section. Air handling section fan: Double intake centrifugal type with blades facing forwards for greater silence, coupled using belts and pulleys with variable pitch. The direction of delivery air flow can be: UPWARDS, SIDEWAYS AND DOWNWARDS. complete with electric control board, probes and actuators for all components.

Versions: RTPA F cooling only version. RTPA H heat pump. High temperature functioning (A) Condensation section fans: Silenced functioning (L) Statically and dynamically balanced helical SET-UPS: type, protected electrically by magnet circuit breakers and mechanically by grids. SMP mixing chamber 2 dampers with rear intake. Cooling circuit: SM2 mixing chamber 2 dampers with lateral/ Fitted with scroll compressors that guarantee lower intake. low noise and high efficiency, complete with SM3 mixing chamber 3 dampers with free-cooresistances on the guard, internal and external ling. coil with copper pipes and high efficiency alu- FT7 F7 (EN 779) efficiency rigid pocket filters. minium louvers. REC cross flow heat recovery units with intake fan. Air filtering: Gxxx condensation hot air generator (72 kW, 92 Pleated synthetic filters with G4 efficiency or F7 kW or 150 kW). rigid pocket filters (optional). Microprocessor adjustment

Accessories
DCPR - Pressure control device Extends the functioning range of the rooftop in the summer cycle (minimum temperature of the external air up to 10 C) and in the winter cycle in heat pump mode (maximum temperature of the external air up to 25 C). Moreover, it makes functioning silent with partial loads. A regulation circuit board varies the number of the motor condensing fan revs on the basis of the condensation pressure, read by the relevant transducers, thus guaranteeing correct power supply of the thermostatic valve. TP - Pressure transducers (as per standard on heat pumps) They show the high and low pressures on the display, they manage activity of the compressors and the valves during defrosting and inhibit their functioning when the pressures exceed the limits set. RUB - Cocks on the liquid and pressing line (cooling only version) Hermetic cocks with manual closure positioned on the compressor delivery and on the circuit liquid side GP - Protection grids Protect the external coils from blows and hail. T1 - Right lateral air intake (only on SM2). T2 - Left lateral air intake (only on SM2). T3 - Rear air intake (only on SM2). T4 - Lower air intake (only on SM2). T5 - Right lateral air intake (only on SM2). T6 - Left lateral air intake (only on SM2).

314

AI - Lower intake (only on SM3). PA4 - Rear air intake Return fan static pressure up to 300 Pa at nominal ow rate. MA - Upper air delivery Upper air delivery, delivery fan static pressure up to 200 Pa at nominal air ow rate. MA - Left air delivery Left air delivery, delivery fan static pressure up to 200 Pa at nominal air ow rate. MD - Right air delivery Right air delivery, delivery fan static pressure up to 200 Pa at nominal air ow rate. PM4 - Delivery fan static pressure up to 400 Pa Delivery fan static pressure up to 400 Pa at nominal ow rate. BTR - Water heating coil 2 row hot water coil with 3-way modulating valve. They can be managed in post-heating mode only with DP accessories. They can be coupled with the G72 or G92 generator. BRE - Electric heating coil Electric heating coil with two stages tted with twin safety thermostat, one with automatic rearm and the other with manual rearm. The powers proposed are 12, 18, 24 and 36 kW (or indicate the power requested in the order phase). They can be managed in post-heating mode only with DP accessories. The BRE cannot be coupled with the G72 or G92 generator. PUC - Humidication control set-up. ON/ OFF contact (normally open) for humidication consent. In this case, the unit is complete with humidity probe positioned in the enviAccessories coupling Version

ronment air return. A humidity probe is also supplied to be positioned downstream from the humidication section. DP - Kit for management of dehumidication and post-heating The control will force compressor functioning in order to dehumidify the air to the set humidity set. If the water or electric coil is present, post-heating can also be managed. It can be coupled with the PUC accessory (humidication contact). SCS - Damper servocontrols for 2-damper set-up Modulating servocontrols mounted directly on the return and external dampers for the management of fresh air. SCSM - Damper servocontrols with spring return for 2-damper set-up Servocontrols with spring return mounted directly on the return and external dampers for the management of fresh air. In the event of blackout they close the external air damper completely and completely open the fresh air damper. SCM3 - Damper servocontrols with spring return for 3-damper set-up. Servocontrols with spring return mounted directly on the dampers for management of freecooling as a replacement for the standard ones. In the event of blackout they close the external air dampers completely and completely open the fresh air damper. FCH - Enthalpy Free-cooling Only with 3-damper mixing chamber. Manages the ow of external and return air, making reference to their enthalpy values.

PR2 - Remote panel Allows to perform rooftop control operations from a distance. SSV - RS485 serial interface for supervision Serial board necessary for the interface with supervision systems. SQA - Air quality probe. It analyses the quality of the air on the basis of a SnO2 sensor with VOC mixed gas, evaluating contamination by polluting gases. The presence of the probe coupled to the rooftop allows: - to set a sensitivity threshold depending on the envisioned maximum contamination of the air. - the ventilation of the rooms only when necessary, thus guaranteeing energy saving. TV2 - Power supply voltage 3/230V/50Hz. TV3 - Power supply voltage 3/460V/60Hz. VTR (3 - 5 - 7) - Anti-vibration mounts Rubber anti-vibration mounts. PF - Filters dirtying pressure switch BSP - Special coils Condensing coils with copper pipes and pre-painted aluminium louvers. BSR - Special coils Condensing coils with copper pipes and copper louvers. BSS - Special coils Condensing coils with copper pipes and tinned copper louvers. NOTE: for further information refer to the technical manual.

Size 240 - 260 - 300 -350 - 400 cooling only (F) Heat pump (H) L (no 350 and A (no 350 and L (no 350 and A (no 350 and Functioning std std 400) 400) 400) 400) DCPR as per standard as per standard TP as per standard as per standard as per standard RUB GP T1 (1) T2 (1) T3 T4 T5 (1) T6 (1) AI PA4 MA MS (1) MD (1) PM4 BTR BRE PUC DP SCS SCSM SCM3 FCH PR2 SSV SQA TV2 TV3 VTR3 (basic set-up) VTR5 (for units from 5 to 7.1 m) VTR7 (for units over 7.1 m) PF BSP BSR BSS (1) Right or left direction refers to the direction of air flow inside the handling sections.

315

Technical data

RTE F Cooling capacity Sensitive nominal cooling capacity Compressor input power EER RTE H Cooling capacity Sensitive nominal cooling capacity Compressor input power EER Heating capacity Compressor input power COP Nominal air ow rate internal fans Minimum air ow for the handling section Maximum air ow for the handling section Compressors Cooling circuits External fans Nominal air ow rate Internal fans Maximum available pressure Air lters Thickness Evaporator Water coil heating capacity * Gas heating module heating capacity Sound pressure level Electrical power supply V/Ph/Hz * Room air 20C d.b., water 80/70C. Cooling capacity RH 50% (Twb 19C), Text 35C RH 50%; Operation with 30% of ambient air and expelled (version with mixing chamber with three dampers SM3). Nominal air ow. kW kW kW W/W kW kW W/W m3/h m3/h m3/h Type n n Type n m3/h q.t Pa Type mm Type kW 240 81,8 49,7 16 5,11 77,5 13,4 5,8 260 93,4 61,8 18,9 4,94 89,9 14,4 6,2 kW kW kW W/W 240 82,5 50,2 16 5,16 260 94,2 61,8 18,9 4,98

Standard 300 109,7 66,6 23,6 4,65 Standard 300 111,8 67,2 23,6 4,74 107,7 17,3 6,2

350 137,9 77,8 28,6 4,82

400 152,1 83,1 33,9 4,49

High temperature (A) 240 260 300 83,7 96,6 116,1 50,2 61,6 67,7 16,5 18,8 23 5,07 5,14 5,05 High temperature (A) 240 260 300 82,9 95,7 114,9 49,7 61,6 67,7 16,5 18,8 23 5,02 5,09 5,00 81,1 95,6 106,2 13,8 15,3 17,9 5,9 6,2 5,9

Low noise (L) 240 260 300 74,1 89,1 109,3 45,9 59,3 66,3 17,5 21,6 24,6 4,23 4,13 4,44 Low noise (L) 240 260 300 72,3 89,1 90,4 45,9 59,3 64,2 17,5 21,6 21,7 4,13 4,13 4,17 78 88,8 88,1 13,9 15 17,8 5,6 5,9 4,9

350 137 77,1 28,6 4,79 133 22,5 5,9

400 150 83,1 33,9 4,42 148 26,8 5,5

12.000 17.000 20.000 22.000 23.000 12.000 17.000 10.400 14.800 17.400 19.100 19.550 10.400 14.800 14.100 20.000 23.500 23.500 23.500 14.100 20.000 Scroll 2 2 Axial 4 32.000 29.000 28.000 40.000 34.200 29.000 28.000 1 200 G4 50 4 140 179 200 213 219 140 179 72 92 92 92 92 72 92 kW 92 150 150 150 150 92 150 dB(A) 72 73 74 77 78 72 73 400/3+N/50

20.000 12.000 17.000 20.000 17.400 10.400 14.800 17.400 23.500 14.100 20.000 23.500

33.000 19.000 18.000 22.000

200 92 150 74

140 72 92 69

179 92 150 70

200 92 150 71

Heating capacity Heating capacity Tin 20C RH 50%, Text 7C RH 70%. Operation with 30% of ambient air and expelled (version with mixing chamber with three dampers SM3). Nominal air ow.

Sound pressure: Sound pressure in free eld, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

316

Dimensional data (mm)

C B

RTE Height Width Depth Weight RTE Weight RTE H

A B C

mm mm mm kg kg

240 1.830 2.166 3.290 1300 1320

260 1.830 2.166 3.290 1390 1410

300 1.830 2.166 3.290 1480 1500

350 1.830 2.166 3.286 1.565 1.645

400 1.830 2.166 3.286 1.645 1.725

Dimensions and weights of the basic set-up unit.

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

317

Code : SRTE240_400UY.01 /1301

RTE

ROOF-TOP cooling only and heat pump unit Cooling capacities from 150 up to 254 kW standard version Heating capacities from 151 up to 266 kW standard version

Features
The rooftop units in the RTE range represent the ideal solution for air conditioning environments with average and large cubage for tertiary, commercial and industrial destination. The units offer noteworthy advantages in terms of air quality and environmental comfort, easy installation and low noise level. The use of ecological R410A fluid refrigerant allows to increase the unit efficiency. The availability of many accessories, e.g. the cross flow recovery systems or the hot air generator with condensation, also confer a noteworthy versatility, making the RTE range perfectly suitable for the various system requirements. and pulleys with variable pitch. The direction of delivery air flow can be: Versions: UPWARDS, SIDEWAYS AND DOWNWARDS. RTPA F cooling only version. RTPA H heat pump. Condensation section fans: High temperature functioning (A) Statically and dynamically balanced helical Silenced functioning (L) type, protected electrically by magnet circuit SET-UPS: breakers and mechanically by grids. SMP mixing chamber 2 dampers with rear intaDouble cooling circuit: ke. which at the same time guarantees the respect SM2 mixing chamber 2 dampers with lateral/ for the environment and the increase of energy lower intake. efficiency. The cooling circuit lines and the elec- SM3 mixing chamber 3 dampers with free-cootric plant wiring are inserted into the base of the ling. machine with the purpose of making mainte- FT7 F7 (EN 779) efficiency rigid pocket filters. nance and internal cleaning easier. REC cross flow heat recovery units with intake Structure: Scroll tandem compressors that guarantee low fan. Self-supporting with external aluminium alloy noise and high efficiency. Gxxx condensation hot air generator. and internal galvanised steel sandwich-type Internal and external coil with copper pipes and panelling with thickness of 50 mm and injected high efficiency aluminium louvers. polyurethane insulation (density 42 kg/m3) for the air handling section. Air filtering: Pleated synthetic filters with G4 efficiency or F7 Air handling section fan: rigid pocket filters (optional). Double intake centrifugal type with blades Microprocessor adjustment facing. complete with electric control board, probes forwards for greater silence, coupled using belts and actuators for all components.

Accessories
DCPR - Pressure control device (as per standard for silenced functioning mode) Extends the functioning range of the rooftop in the summer cycle (minimum temperature of the external air up to 10 C) and in the winter cycle in heat pump mode (maximum temperature of the external air up to 25 C). Moreover, it makes functioning silent with partial loads. A regulation circuit board varies the number of the motor condensing fan revs on the basis of the condensation pressure, read by the relevant transducers, thus guaranteeing correct power supply of the thermostatic valve. GP - Protection grids Protect the external coils from blows and hail. T1 - Right lateral air intake (only on SM2). T2 - Left lateral air intake (only on SM2). T4 - Lower recirculation air intake. rear fresh air intake (only on SM2). T5 - Right lateral recirculation air intake. left fresh air intake (only on SM2). T6 - Left lateral recirculation air intake. right fresh air intake (only on SM2). AI - Lower intake (only on SM3). PA4 - Rear air intake Return fan static pressure up to 300 Pa at nominal flow rate. MA - Upper air delivery. MS - Left air delivery nominal air flow rate. MD - Right air delivery. PM4 - Delivery fan static pressure up to 400. Pa Static pressure of the delivery fan up to 400 Pa at nominal flow rate. BTR - Water heating coil 2 row hot water coil with anti-freeze probe as per standard. They can be

318

managed in post-heating mode only with DP accessories. They can be coupled with the Gxxx generator. V3V - 3-way valve with servocontrol modulating for the management of the water coil mounted inside the rooftop BRE - Electric heating coil Electric heating coil with two stages fitted with twin safety thermostat, one with automatic rearm and the other with manual rearm. They can be managed in post-heating mode only with DP accessories. The BRE cannot be coupled with the Gxxx generator. PUC - Humidification control set-up. ON/OFF contact (normally open) for humidification consent. In this case, the unit is complete with humidity probe positioned in the environment air return. A humidity probe is also supplied to be positioned downstream from the humidification section. DP - Kit for management of dehumidification and post-heating The control will force compressor functioning in order to dehumidify the air to the set humidity set. If the water or electric coil is present, post-heating can also be managed. It can be coupled with the PUC accessory (humidification contact). SCSR - Recirculation damper for SMP mixing chamber.

SRP - Recirculation damper for the SMP mixing chamber and modulating servocontrol (joined dampers). SCMP - Recirculation damper for the SMP mixing chamber and modulating servocontrol with spring return. SCS2 - Recirculation damper for SM2 mixing chamber. SR2 - Recirculation damper for the SM2 mixing chamber and modulating servocontrol. SCM2 - Recirculation damper for the SM2 mixing chamber and modulating servocontrol on return and modulating servocontrol with spring return on fresh air. SCM3 - Modulating servocontrols with spring control for SM3 or REC set-ups. FCH - Enthalpy Free-cooling Only with 3-damper mixing chamber. Manages the flow of external and return air, making reference to their enthalpy values. PR2 - Remote panel Allows to perform rooftop control operations from a distance. SSV - RS485 serial interface for supervision Serial board necessary for the interface with supervision systems. SQA - Air quality probe. It analyses the quality of the air on the basis of a SnO2 sensor with VOC mixed gas, evaluating contamination by polluting gases. The presence of the probe coupled to the

rooftop allows: - to set a sensitivity threshold depending on the envisioned maximum contamination of the air. - the ventilation of the rooms only when necessary, thus guaranteeing energy saving. CAF - For protection of the external air inlets in the mixing chambers with 2 dampers or recovery unit. As per standard with SM3. CF - Stainless steel flue, double isolated wall with inspection cap and measuring sump with flue gas temperature thermometer. PF - Filters dirtying pressure switch. RUB - Cocks on the liquid and pressing line (cooling only version). NOTE: for further information refer to the technical manual.

Accessories coupling Version Functioning DCPR TP GP T1 T2 T4 T5 T6 AI PA4 MA PM4 BTR V3V BRE (1) PUC DP SCSR SRP SCMP SCS2 SR2 SCM2 SCM3 FCH PR2 SSV SQA CAF CF (only with Gxxx) PF RUB VT

std

Size 480-530-600-700-800 cooling only (F) Heat pumps (H) L A (no 700 - 800) std L standard standard standard standard

A (no 700 - 800) standard

(1) Not available with Gxxx set-ups.

319

Technical data
RTE F Cooling capacity Sensitive nominal cooling capacity Compressor input power EER RTE H Cooling capacity Sensitive nominal cooling capacity Compressor input power EER Heating capacity Compressor input power COP Nominal air ow rate internal fans Minimum air ow for the handling section Maximum air ow for the handling section Compressors Cooling circuits External fans Nominal air ow rate Internal fans Maximum available pressure Air lters Thickness Evaporator Sound pressure level Electrical power supply V/Ph/Hz RTE F Cooling capacity Sensitive nominal cooling capacity Compressor input power EER RTE H Cooling capacity Sensitive nominal cooling capacity Compressor input power EER Heating capacity Compressor input power COP Nominal air ow rate internal fans Minimum air ow for the handling section Maximum air ow for the handling section Compressors Cooling circuits External fans Nominal air ow rate Internal fans Maximum available pressure Air lters Thickness Evaporator Sound pressure level Electrical power supply V/Ph/Hz Cooling capacity RH 50% (Twb 19C), Text 35C RH 50%; Operation with 30% of ambient air and expelled (version with mixing chamber with three dampers SM3). Nominal air ow. kW kW kW W/W kW kW W/W m3/h m3/h m3/h Type n n Type n m3/h n Pa Type mm Type dB(A) 480 154,4 119,1 42,6 3,62 157 28,6 5,49 26.500 22.500 30.500 530 188,3 145,9 43,8 4,30 186,7 31,5 5,93 29.500 25.000 34.000 kW kW kW W/W 480 157,6 123,7 40,7 3,87 530 189,3 147,2 42,9 4,41 kW kW kW W/W kW kW W/W m3/h m3/h m3/h Type n n Type n m3/h n Pa Type mm Type dB(A) 480 155,7 120,5 41,4 3,76 158,1 28,7 5,51 26.500 22.500 30.500 530 188,3 145,9 43,8 4,30 186,4 31,5 5,92 29.500 25.000 34.000 kW kW kW W/W 480 160,6 119,5 39,3 4,09 530 189,8 147,1 43,1 4,40 Standard 600 210,9 159,3 47 4,49 Standard 600 207,9 157,8 48,8 4,26 212,7 37 5,75 31.500 26.800 36.300 700 247 184,5 58 4,26 800 274,4 201,5 69,9 3,93 High temperature (A) 480 530 600 167,3 195,6 223,6 123,3 149,6 150,5 36,9 40,9 45,1 4,53 4,78 4,96 High temperature (A) 480 530 600 163,7 190,5 219,3 122,8 147,4 158,8 37,5 42,4 47,6 4,37 4,49 4,61 167,3 191,6 217,2 29,5 31,8 36,9 5,67 6,03 5,89 26.500 29.500 31.500 22.500 25.000 26.800 30.500 34.000 36.300

74.600

72.400

69.200

3 82

4 83

4 84

700 800 245,8 272,2 183,1 201,2 59,1 70,9 4,16 3,84 242,2 278,8 49,2 60,4 4,92 4,62 35.000 38.500 29.800 32.700 40.300 44.300 Scroll tandem 4 2 Axial 4 84.400 80.600 1 200 G4 50 4 4 87 88 400/3/50

72.400

69.200

67.400

4 82

4 83

4 84

Silenziata L 600 215,6 160,3 45,1 4,78

700 245,4 184,3 58,7 4,18

800 268 199,6 73,3 3,66

74.600

72.400

3 82

4 83

Standard 600 700 211,8 242,5 159,8 182,5 46,5 60,7 4,55 4,00 205,8 238,9 36,4 48,9 5,65 4,89 31.500 35.000 26.800 29.800 36.300 40.300 Scroll tandem 4 2 Axial 4 69.200 84.400 1 200 G4 50 4 4 84 87 400/3/50

800 266 198,7 74,6 3,57 262,8 58,5 4,49 38.500 32.700 44.300

80.600

4 88 Sound pressure: Sound pressure in free eld, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744)

320

Heating capacity Heating capacity Tin 20C RH 50%, Text 7C RH 70%. Operation with 30% of ambient air and expelled (version with mixing chamber with three dampers SM3). Nominal air ow.

Dimensional data (mm)

C B

RTE Height Width Depth Depth RTE Depth RTE H

A B C

mm mm mm kg kg

480 2450 2350 4200 2100 2200

530 2450 2350 4200 2200 2300

600 2.450 2.350 4.200 2300 2400

700 2.450 2.350 5.500 2700 2800

800 2450 2350 5500 2800 2900

Dimensions and weights of the basic set-up unit.

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

321

Code : SRTE480_800UY.01 /1301

MEC-W
R407C

Water-cooled packaged air conditioners With radial fans and capacities from 11 up to 55 kW

Features
Available in 5 different sizes All versions are supplied for use with R407C Metallic protective cabinet with rustproof polyester paint Double suction radial fans Electric motors with belt transmission Four row evaporator coil with copper tubes Plate-type condenser and aluminium fins Water flow control valve driven directly in Washable air filter relation to condensing pressure Room thermostat with one or two contacts depending on the model Hermetic compressors

Accessories
BAS: Hot water coil with three rows of alumi- PL: Air distribution plenum comprising delinium finned copper tubes. very grille with two rows of adjustable slats and internal lining of sound insulating material.

Compatibility of accessories
Mod. BAS 30 BAS 50 BAS 75 BAS 100 BAS 150 BAS 200 BAS 300 PL 22 PL 23 PL 26 PL 37 PL 38 PL 39 PL 300 307 W 507 W 757 W 1007 W 1507 W

322

Technical data
Mod. MEC Cooling capacity Input power Water flow rate at 30 C Pressure drops Water consumption at 16 C* Pressure drops* Heating capacity (accessory BAS) Pressure drops (accessory BAS) Coil rows Nominal air flow rate e Sound pressure Motor power Speed Motor pulley diameter Fan pulley diameter Air flow rate Input current Peak current Power supply: 3~ 230V 50Hz; 3N~ 400V 50Hz. Cooling room air temperature 27 C D.B., 19 C W.B.; condensing temperature 40 C; condensing temperature 35 C. Heating water inlet temperature 85 C; air intake temperature 15 C; Sound pressure measured in an 85 m3 semi-reverberant test chamber with reverberation time Tr = 0.5s.. kW kW l/h kPa l/h kPa kW kPa n. m3/h dB (A) kW g/m (min.) g/m (max.) mm (min.) mm (max.) mm m3/h (min.) m3/h (max.) A (230 V) A (400 V) A (230 V) 307 W 11 3,05 2350 38 620 3,5 25,28 3,47 4 2040 63 0,375 840 1120 79 104 130 1600 2400 12,2 6 98 48 507 W 18 4,45 3740 65 990 6,7 46,61 4,01 4 3400 65,5 0,75 840 1120 79 104 130 2750 4100 15,4 8,9 142 68 757 W 29 7,3 5900 56 1550 5 58,01 3,97 4 5100 72,5 1,125 840 1120 79 104 130 4100 6000 24,2 13,9 168 101 1007 W 35 8,5 7270 65 1910 5,3 78,59 4,59 4 6800 69,5 1,5 620 810 79 104 180 5500 8200 30,8 17,8 157 77 1507 W 55 13,7 11270 53 2970 5 113,68 5,77 4 10200 73,5 1,125 840 1120 79 104 130 8200 12000 46,6 26,9 190 115

Dimensions (mm)

Mod. Height Width Depth Weight

A B C kg

307 W 1290 900 494 147

507 W 1410 1040 558 184

757 W 1680 1220 648 273

1007 W 1700 1450 723 335

1507 W 1745 1880 753 484 Cod.: SMECUY.03 / 0301

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Fax 044293730 www.aermec.com

323

SAP

Buffer tank with capacity from 75 to 3500 litres

Features
Buffer tank with pump fully assembled to be Pump motors protected by circuit breakers al. used together with water chillers. Hydraulic SAP 0075 and 0150 can be supplied with 5 SAP 1500, 2500 and 3500 can be supplied connections to be site installed different pump models with water flow rates with 10 models of pumps with water flow Units dimensionally compatible with Aermec up to 18,000 l/h and pressures up to 140 kPa rates up to 200,000 l/h and pressures up to NBW, NRA, R, RV water chillers, but also (maximum 2 pumps can be installed internal300 kPa (pump set configurations with standcompatible with any chiller ly) by pump are possible). For correct sizing of Steel enclosure with epoxy powder coating SAP 0300, 0500, 0501, 0750 and 1000 can the unit consult the technical manual. for the maximum resistance to weathering be supplied with 8 models of pumps with Electric centrifugal pumps with stainless steel water flow rates up to 60,000 l/h and presimpeller sures up to 200 kPa (pump set configurations Overpressure relief valve with standby pump are possible). For correct Fully insulated water circuit sizing of the unit consult the technical manu-

Accessories
AVX: Spring anti-vibration mounts. Select the thermostats to prevent freezing during winter. AVX model from the compatibility table Factory fitted only. included in the technical manual. VT: Anti-vibration mounts, set of four anti RX - RXV: Electric immersion heater (RX: 500 vibration mounts to be installed under the W - RXV: 3 kW), installed and controlled by units base.

SAP 0075 0150 0300 0500 - 0501 0750 1000 1500 2500 3500

Accessory compatibility RX RXV VT 2

VT 8

324

Connection Schematic Example

PRIMARY CIRCUIT chiller

PRIMARY-SECONDARY CIRCUITUBLE RING

chiller

Technical Data
Mod. SAP Capacity Expansion tank capacity Relief valve setting Water connections Connection diameter 0075 75 8 6 F 1 1/4 0150 150 12 6 F 1 1/2 0300 300 18 6 F 2 0500 500 24 6 F 2 1/2 0501 500 24 6 F 2 1/2

l l bar (1)

Mod. SAP Capacity Expansion tank capacity Relief valve setting Water connections Connection diameter

l l bar (1)

0750 750 18 x 2 6 F 3

system

1000 1000 18 x 2 6 F 3

1500 1500 24 x 2 6

2500 2500 24 x 3 6

3500 3500 24 x 3 6

Model Pump 1500 flange (*) 2500 flange (*) 3500 flange (*)

R 125 125 125

T 125 125 125

U 150 150 150

V 150 150 150

X 150 150 150

Y 150 150 150

W 200 200 200

K 200 200 200

J 200 200 200

Power supply = 3N~ 400V 50Hz. (1) F = Female connection (Gas) (*) PN16UNI2278

system
I 200 200 200

325

Technical Data
Pump motor power input Pump Max. input power Max. input current Pump Max. input power Max. input current

W A

A 275 0,5

B 330 0,69

C 614 1,1 N 1470 2,6

E 895 1,6 P 2600 4,4

F 1070 1,9 Q 5200 8,8

G 1550 2,8 R 4000 8,5

H 2050 3,6 T 5200 11,5

I 22000 43 U 5800 15,5

J 17500 36,4 V 8000 15,5

K 14500 30 W 11500 22,5

L 3100 5,6 X 9000 22,5

M 4100 7,2 Y 11000 22,5

W A

Pump combinations SAP 0075 SAP 0150 SAP 0300 SAP 0500 SAP 0501 SAP 0750 SAP 1000 SAP 1500 SAP 2500 SAP 3500

AC AC EC

AE AE EE

AF AF EF

AZ AZ EZ FS FS FS LS JS VS JS VS JS VS

BC BC FC FZ FZ FZ MZ LZ JZ VZ JZ VZ JZ VZ

IS IS IS

IZ UZ IZ UZ IZ UZ

BE BE FE CS GS GS GS NS MS KS WS KS WS KS WS

BF BF FF CZ GZ GZ GZ NZ MZ KZ WZ KZ WZ KZ WZ

BZ BZ FZ ES HS HS HS PS NS RS XS RS XS RS XS

ZC CC ZC EZ HZ HZ HZ PZ NZ RZ XZ RZ XZ RZ XZ

ZE CE ZE FS PS PS LS QS QS TS YS TS YS TS YS

ZF CF ZF FZ PZ PZ LZ QZ QZ TZ YZ TZ YZ TZ YZ

ZZ CZ ZZ ZZ ZZ ZZ MS ZZ ZZ US ZZ US ZZ US ZZ

1st letter: primary circuit. 2nd letter: secondary circuit. A, B = multi-speed water pumps. L, M, Q = twin pump set. S = pump and standby pump set. Z = without pump. The combinations shown in the table are the only possible ones. A large number of different flow rate/pressure combinations are available. Refer to the technical manual.

326

Dimensions (mm)

SAP 0075 - 0150

SAP 0300 - 0500

SAP 0501 - 0750

SAP 1000 - 1500 - 2500 - 3500

SAP Height Width Depth Net weight (ZZ version)

A B C kg

0075 1000 1000 700 120

0150 1000 1000 700 120

0300 1650 1100 1100 190

0500 1650 1100 1100 230

0501 1968 1550 1000 310

0750 1968 1550 1000 400

1000 2049 2200 1000 445

1500 2049 2200 1750 560

2500 2049 2200 2000 710

3500 2049 2200 2300 790

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

327

Cod.: SSAPUY.05 / 0702

TRA

Cooling towers with capacities from 49.53 up to 1084.88 kW

Features
Available in 17 different sizes - TRA from 50 up to 750 silenced and Inspection window standard - TRA from 850 up to 1100 standard TRA from 850 up to 1100 silenced (L) All with inspection door to a crawl Series Entirely built of fibre-glass reinforced resin to avoid corrosion problems with surface treatment to withstand ultraviolet rays, heat changes and scuffing caused by bad weather Limited to the three largest sizes (TRA 850, 950 and 1100) the bearing structure is made of hot galvanised steel with 22mm thick fibreglass reinforced resin sandwich panels, with support foam material inside. In this way, as well achieving good mechanical strength the Axial high efficiency fan with several blades sound of the water flowing is muffled. Surface Water drip pan, waterproof and water resitreatment to withstand ultraviolet rays, heat stant made of fibreglass reinforced polyester changes and scuffing caused by bad weather. resin with multi layer glass material Self-bearing structure Personal protection grill made of AISI 304 on Exchange pack and drip separator made of the fan outlet self-extinguishing PVC P V C wa t e r d i s t r i b u t i o n p i p e s w i t h polypropylene nozzles Hydrometer (when there is not water flow rate measuring device, this instrument makes possible to have an approximate indication of the flow rate of the water in circulation based on the nozzle load drop) Plastic bleed cock

Accessories*
RT: Heater element with regulating thermostat.
Compatibility of accessories 200 240 300 400

TRA RT 11 (1 kW) RT 12 (2 kW) RT 13 (3 kW) RT 15 (5 kW) RT 17 (7.5 kW)

50

70

90

110

130

170

500

550

600

750

850

950

1100

N.B. = In the case of RT accessories, the number between brackets indicates the capacity of the heater element. * = All the accessories and/or variants must in all cases be specified when the order is placed.

328

Technical data
Mod. TRA Capacity Air flow rate Water flow rate Pressure drops Motor power Motor poles Motor poles (double polarity) Fans Nozzles e Sound pressure Mod. TRA Capacity Air flow rate Water flow rate Pressure drops Motor power Motor poles Motor poles (double polarity) Fans Nozzles e Sound pressure e Sound pressure (silenced version) * = Sizes from 50 to 750 are only muted. Power supply = 3~ 230V 50Hz; 3N~ 400V 50Hz. Performance values refer to the following conditions: e Sound pressure measured in free field conditions at distance of 10 m with direction factor = 2. - air inlet temperature 23.5 C W.B.; - water inlet temperature 35 C; - water outlet temperature 29 C 50 49,53 4500 7100 42 0,55 4 4/8 1 1 52 400 405,35 28350 58100 28 2,2 6 6/8 1 4 57 70 69,06 4500 9900 32 0,75 4 4/8 1 1 52 500 488,37 28350 70000 40 4 6 6/12 1 4 57 90 88,60 8100 12700 52 0,75 4 4/8 1 1 54 550 574,19 36000 82300 55 5,5 6 6/12 1 4 58 110 107,44 8100 15400 32 0,75 4 4/8 1 1 54 130 125,58 8100 18000 42 1,1 6 6/12 1 1 54 170 168,14 12600 24100 28 1,1 6 6/12 1 1 54 200 197,67 12600 28330 35 1,5 6 6/8 1 1 54 240 242,09 18100 34700 23 1,5 6 6/8 1 4 55 950 941,86 58000 135000 25 5,5 8 8/16 1 16 62 56 300 302,33 18100 43300 40 2,2 6 6/8 1 4 55 1100 1084,88 67000 155500 32 7,5 8 8/16 1 16 64 57

kW m3/h l/h kPa kW n. n. n. n. dB (A)

kW m3/h l/h kPa kW n. n. n. n. dB (A) dB (A)

600 604,88 45350 86700 30 4 6 6/12 1 9 61

750 767,44 45350 110000 48 5,5 6 8/16 1 9 61

850 856,74 58000 122800 49 5,5 8 8/16 1 16 62 56

Dimensions (mm)

TRA 50-750

TRA 850-1100 TRA 850L-1100L 70 2110 800 800 75 550 3380 1900 2100 500 90 2595 1000 1000 85 600 3450 2100 2300 555 110 2595 1000 1000 95 750 3450 2100 2300 580 130 2595 1000 1000 95 850 3650 2030 2360 850 170 2800 1200 1200 170 850L 3900 2030 2360 850 200 2800 1200 1200 170 950 3650 2030 2360 815 240 2860 1400 1400 210 950L 3900 2030 2360 815 300 2860 1400 1400 210 1100 3650 2360 2360 915 400 3140 1740 1740 410 1100L 3900 2360 2360 915

Mod. TRA Height Width Depth Weight

A B C kg

500 3140 1740 1740 410

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

329

Cod.: STRAUY.03 / 1211

Mod. TRA Height Width Depth Weight

A B C kg

50 2110 800 800 75

CSE - CDR - CVA - CVR


Air remote condensers

CSE

CDR-CVR

CVA

Characteristics
CSE SERIES General characteristics Modularity has been prioritized in the design: each unit is made up of standard sections, whose elements are easily dismantlable Starting from the CSE 563 in the 500 series, and from the CSE663 in the 630 series, there are models made up of two units side by side, making vertical installation impossible. All the other models are designed for either horizontal or vertical installation. To facilitate the connection of the condensers to the electrical system, the fan motors are wired in the factory (excluding the 350 diameter series) and connected to a junction box located on the manifold side and protected, together with the manifolds, by an easily removable cover. Construction characteristics They are designed for outdoor installation and therefore made with technologies and materials which ensure resistance to atmospheric agents Coils with staggered copper pipes and corrugated aluminium fins, mechanically expanded. The coils are fixed at the shoulders so as to avoid breakage of the tubes as a result of any vibration. Manifolds in copper with connectors for soldering, sealed to prevent the ingress of impurities and moisture into the circuits. Latest generation of axial fans to ensure silent operation and high output, protection grade IP54. They are intended for /Y connection and various polarities, and allow continuous regulation of the speed by reducing the voltage. Available versions: (B) basic (S)silenced (E) extra silenced. SERIES CDR General characteristics Two exchangers arranged in a V Two independent cooling circuits Two rows of fans, diameter 800mm From 6 to 10 fans Separate ventilation compartment for each fan Construction characteristics They are designed for outdoor installation and therefore made with technologies and materials which ensure resistance to atmospheric agents High-efficiency finned exchangers Latest generation of axial fans to ensure silent operation and high output, protection grade IP54. The standard units are supplied with the fans wired up to a junction box. Separate airflow for each fan. Available versions: (BT) basic 6 pole (ST)silenced 8 pole (ET) extra silenced 12 pole CVA SERIES General characteristics Exchangers in W configuration Low noise Two rows of fans, diameter 800mm With 6 to 8 fans Construction characteristics They are designed for outdoor installation and therefore made with technologies and materials which ensure resistance to atmospheric agents 4 high-efficiency finned exchangers Latest generation of axial fans to ensure silent operation and high output, protection grade IP54. The standard units are supplied with the fans wired up to a junction box. Separate airflow for each fan. Available versions: (BT) basic 6 pole (ST)silenced 8 pole CVR SERIES General characteristics Two exchangers arranged in a V Diameter of fans 800 mm From 2 to 5 fans Separate ventilation compartment for each fan Construction characteristics They are designed for outdoor installation and therefore made with technologies and materials which ensure resistance to atmospheric agents High-efficiency finned exchangers Latest generation of axial fans to ensure silent operation and high output, protection grade IP54. The standard units are supplied with the fans wired up to a junction box. Separate airflow for each fan. The extremely small dimensions allow installation in restricted spaces, high power output for area occupied Available versions: (BT) basic 6 pole (ST)silenced 8 pole (ET) extra silenced 12 pole

330

Choice of unit
By suitably combining the numeurus options available, its possible to configure each model in such a way as to meet the most particular of system requirements.

Fielf configurator:

1 2 3 4 5 6 7 8 9 10 11 | | | | | | | | Code | | n rows | Power supply | | Fans n coil Motor Electrical Refrigerant Fans type connection Size: CSE-CVR-CVA-CDR Gas: X - R410A - Fluidi refrigeranti con PS max 28 bar fans (mm): 3 - 350 5 - 500 6 - 630 8 - 800 9 - 910 n fans: * - da 1 a 16 N rows: * - da 2 a 6 motor type: B - Standard S - Silenced E - Extra silenced C - Brushless motor with electronic commutation (EC) Power supply: T - 400V/3/50Hz M - 230V/1/ 50Hz Electrical connection: D - Triangle Y - Star - Monophase

Combinations
To facilitate the choice of condenser, we have provided tables below with the combinations of condeseless Aermec unit. The combinations specified require the compulsory use of an RPM regulator and an electrical panel, to ensure correct operation under varying external conditions.

number of remote condensers

number of circuits of remote condenser

condensing temperature C

WRL025E WRL030E WRL040E

1 1 1

WRL050E

WRL070E WRL080E

1 1

WRL100E

WRL140E

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

CSEX3014SM CSEX3013BM CSEX3012BM CSEX3022SM CSEX3022SM CSEX5014EM CSEX5013STY CSEX5014STD CSEX6013ETD CSEX5025ETY CSEX5013STD CSEX6014STY CSEX5015STD CSEX6014STD CSEX5023STY CSEX6014BTY CSEX6015BTD CSEX6023ETD CSEX6014BTD CSEX6023STD CSEX6024STY

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A

Monophase Monophase Monophase Monophase Monophase Monophase star triangle triangle star triangle star triangle triangle star star triangle triangle triangle triangle star

50 45 50 45 50 45 50 45 45 45 50 45 50 45 45 50 45 45 50 45 45

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

8 9 10 11 15 15 19 19 19 19 23 23 27 27 28 38 37 37 45 48 45

26 36 36 29 29 32 31 38 32 29 38 34 38 42 34 43 49 35 49 45 37

no no no no no no 1/QA1 1/QA1 1/QA1 1/QA1 1/QA1 1/QA1 1/QA1 1/QA1 1/QA1 1/QA1 1/QA1 1/QA1 1/QA1 1/QA1 1/QA1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

no no no no no no no no no no no no no no no no no no no no no

* Accessory to be provided in the order

Sound pressure measued in free field conditions, in cooling mode, at distance of 10m and direction factors = 2 in accordance with the ISO 3744 standard

331

(request for) double coolig circuit *

refrigerant pipeworks kit *

control box type n/Type

ambient temperature C

condenser capacity kW

number of circuits of condenserless unit

Condenserless unit

Sound pressure dB(A)

speed regulator n

wiring connection

transducer n

Condenser

refrigerant

Combinations
number of remote condensers number of circuits of remote condenser condensing temperature C (request for) double coolig circuit *

WRL160E

WRL180E

WRL200E

WRL300E

WRL400E

WRL500E

WRL550E

WRL600E

WRL650E

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

CSEX5024BTY CSEX6023BTY CSEX6033ETD CSEX6023STD CSEX6023BTD CSEX6033STY CSEX6023BTD CSEX6033BTY CSEX6043STY CSEX6024BTD CSEX6033BTD CSEX8024STY CSEX6025BTD CSEX6034BTD CVRX8023STY CSEX6033BTD CSEX8024BTY CVRX8023STD CSEX8033ETD CSEX8024BTY CVRX8023BTD CVRX8033STY CSEX8024BTD CVRX8024BTD CVRX8033STD CVRX8043ETD CVRX8023BTD CSEX8034BTD CVRX8034STD CVRX8043STY CSEX6034BTD CSEX9024BTD CSEX6044BTD CVRX8023BTY CSEX8023BTY CSEX8024BTD CVRX8024BTY CVRX8043ETY CSEX9024BTD CSEX6044BTD CVRX8024BTD CVRX8033STD CSEX9026BTD CVRX8024BTY CSEX9034BTD CVRX8033BTY CVRX8024BTD CSEX9036BTD CDRX8043STD CSEX9034BTD CVRX8034BTD CVRX8043BTY CVRX8054STY CVRX8033BTD CVRX8043BTD CVRX8053STD CDRX8083ETD

1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 2 1 1 2 2 1 2 2 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A

star star triangle triangle triangle star triangle star star triangle triangle star triangle triangle star triangle star triangle triangle star triangle star triangle triangle triangle triangle triangle triangle triangle star triangle triangle triangle star star triangle star star triangle triangle triangle triangle triangle star triangle star triangle triangle triangle triangle triangle star star triangle triangle triangle triangle

50 45 45 50 45 45 50 45 45 50 45 45 50 45 45 50 45 45 46 50 45 45 50 45 45 45 50 45 45 45 50 45 45 45 50 45 45 45 50 50 45 45 50 50 45 45 50 45 45 50 45 45 45 50 45 45 45

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 45 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

54 53 56 64 61 61 81 79 82 91 91 90 99 102 100 122 115 125 118 154 162 151 191 180 188 178 216 215 200 202 137 133 136 130 141 143 145 145 178 182 180 188 202 194 201 196 240 227 221 268 270 262 259 325 325 313 300

45 46 37 45 52 39 52 48 40 52 54 41 52 54 37 54 49 43 40 49 51 39 55 51 45 36 51 57 45 40 54 59 55 44 49 55 44 32 59 55 51 45 59 44 61 46 51 61 46 61 53 47 41 53 54 47 39

1/QA1 1/QA1 1/QA2 1/QA1 1/QA1 1/QA2 1/QA1 1/QA2 1/QA2 1/QA1 1/QA2 1/QA1 1/QA1 1/QA2 1/QA1 1/QA2 1/QA1 1/QA1 1/QA2 1/QA1 1/QA1 1/QA2 1/QA1 1/QA1 1/QA2 1/QA2 1/QA1 1/QA2 1/QA2 1/QA2 1/QA2 1/QA1 1/QA2 1/QA1 1/QA1 1/QA1 1/QA1 1/QA2 1/QA1 1/QA2 1/QA1 1/QA2 1/QA1 1/QA1 1/QA2 1/QA2 1/QA1 1/QA2 2/QA1 1/QA2 1/QA2 1/QA2 1/QA3 1/QA2 1/QA2 1/QA3 2/QA2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

no no no no no no no no no no no no no no yes no no yes no no yes yes no yes yes yes yes no yes yes no no no no no no no no no no no no no no no no no no no no no no no no no no no yes yes yes no yes yes no no yes yes no no yes no yes no no yes no yes no no no no no no no

NXW500E

NXW550E

NXW600E

NXW650E

NXW700E

NXW750E

NXW800E

* Accessory to be provided in the order

Sound pressure measued in free field conditions, in cooling mode, at distance of 10m and direction factors = 2 in accordance with the ISO 3744 standard

332

refrigerant pipeworks kit *

control box type n/Type

ambient temperature C

condenser capacity kW

number of circuits of condenserless unit

Condenserless unit

Sound pressure dB(A)

speed regulator n

wiring connection

transducer n

Condenser

refrigerant

Combinations
number of remote condensers number of circuits of remote condenser condensing temperature C (request for) double coolig circuit *

NXW900E

NXW1000E

NXW1250E

NXW1400E

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1+1 1 1+1 1 1 2 1 2 2 2 2 2

CSEX8043BTD CVRX8034BTD CVRX8044BTD CVRX8054BTY CDRX8083STY CSEX8044BTD CSEX8063BTD CVRX8053BTD CDRX8103ETD CVRX8043BTD CSEX8064BTD CVRX8054BTD CDRX8103STY CVRX8044BTD CVRX8054BTD CDRX8084STD CDRX8104STY CVR833BTD CVR853ETD CSE843BTD CSE863STY CVR834BTD CVR853STY CSE844BTD CSE864STY CVR834BTD CVR843BTD CVR853STD CSE863BTY CVR843BTD CVR844BTD CVR854BTY CSE863BTD CVR853BTD CDR864BTD CDR883STD CDR8104STD CVR854BTD CDR883BTD CDR8103STD CDR883BTD CDR884BTD CDR8104STD CVR843BTD CVR844BTD CDR8103BTD CDR884STY CDR883ETD CDR8103BTD CDR8104BTD CVR854BTY CDR8104BTD CVR853BTD CVA883STD CVR854BTD CVA864BTD CVA884STD

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 2 1 1 1 1 1

R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a

triangle triangle triangle star star triangle triangle triangle triangle Triangle Triangle Triangle Star triangle triangle triangle star triangle triangle triangle star triangle star triangle star triangle triangle triangle star triangle triangle star triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle star triangle triangle triangle star triangle triangle Triangle triangle triangle Triangle

50 50 45 45 45 50 45 45 45 50 45 45 45 50 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

339 361 361 348 348 382 382 406 378 434 430 451 435 481 451 469 440 222 200 232 288 247 229 261 249 247 297 286 288 297 329 317 348 370 405 402 535 412 494 502 494 540 535 297 329 621 320 274 621 675 317 675 370 431 412 415 424

58 53 54 48 43 58 60 55 40 54 60 55 44 54 55 49 44 53 37 58 46 53 41 58 46 53 54 47 54 54 54 48 60 55 56 49 50 55 57 50 57 57 50 54 54 58 43 39 58 57 50 58 57 50 58 57 50

2/QA1 1/QA2 1/QA2 1/QA3 2/QA2 2/QA1 2/QA2 1/QA3 2/QA3 1/QA2 2/QA2 1/QA3 2/QA3 1/QA2 1/QA3 2/QA2 2/QA3 1/QA2 1/QA3 2/QA1 2/QA2 1/QA2 1/QA3 2/QA1 2/QA2 1/QA2 1/QA2 1/QA3 2/QA2 1/QA2 1/QA2 1/QA3 2/QA2 1/QA3 2/QA2 2/QA2 2/QA3 1/QA3 2/QA2 2/QA3 2/QA2 2/QA2 2/QA3 1/QA2 1/QA2 2/QA3 1/QA4 1/QA4 2/QA3 2/QA3 2/QA3 2/QA3 2/QA3 2/QA4 2/QA3 2/QA3 2/QA4

2 1 1 1 2 2 2 1 2 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 1 2 1 1 1 2 1 2 2 2 1 2 2 2 2 2 1 1 2 1 1 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 1 1 2 1 1 2 2 2 2 2 2 2 2 2

no no no no no no no no no no no no no no no no no yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes no no no no no no no no no no yes yes no yes yes no no yes no yes yes yes yes yes

refrigerant pipeworks kit *

control box type n/Type

ambient temperature C

condenser capacity kW

number of circuits of condenserless unit

Condenserless unit

Sound pressure dB(A)

speed regulator n

wiring connection

transducer n

Condenser

refrigerant

no no no no no no no no no no no no no no no no no

WSA/WSB701E

WSA/WSB801E

WSA/WSB901E

WSA/WSB1101E

WSA/WSB1402E

WSA/WSB1602E

WSA/WSB1802E

2 2

WSA/WSB2002E

2 2

WSA/WSB2202E

WSA/WSB2502E

WSA/WSB2802E

* Accessory to be provided in the order

Sound pressure measued in free field conditions, in cooling mode, at distance of 10m and direction factors = 2 in accordance with the ISO 3744 standard

333

Combinations
number of remote condensers number of circuits of remote condenser condensing temperature C (request for) double coolig circuit *

HWF2512E

HWF2812E

HWF3212E

HWF3612E

HWF4212E

HWF4812E

HWF5612E

HWF6412E

HWF2512AE

HWF2812AE

HWF3212AE

HWF3612AE

HWF4212AE

HWF4812AE

HWF5612AE

HWF6412AE

1 1 1 1 1 1 1 1 2 2 1 1 2 1 2 2 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 2 2 1 1 2 1 2 2 1 2 2 2 2 2 2 2 2

CDR8084BTD CDR8104BTD CVA8163STY CDR8103BTD CVA8123BTD CVA8163STD CVA8123BTD CVA8163BTD CVA8103STD CVA8143ETD CVA8123BTD CVA8164BTD CDR8103BTY CVA8163BTD CDR8084BTD CVA8123STD CVA8163BTD CDR8104BTD CVA8143STD CDR8103BTD CVA8123BTD CVA8163STD CDR8103BTD CVA8124BTD CVA8164STD CDR8084BTD CVA8123BTD CVA8163STD CDR8103BTD CVA8124BTD CVA8163BTY CVA8123BTD CVA8163BTD CVA8103STD CVA8143ETD CVA8124BTD CVA8164BTD CDR8104BTY CVA8163BTD CDR8104BTD CVA8124STD CVA8164BTD CVA8104BTD CVA8143BTY CDR8103BTD CVA8124BTD CVA8163STD CDR8104BTD CVA8143BTD CVA8164STD

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a

triangle triangle star triangle triangle triangle triangle triangle triangle triangle triangle triangle star triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle star Triangle Triangle Triangle Triangle triangle triangle star triangle triangle triangle triangle triangle star triangle triangle triangle triangle triangle triangle

50 45.2 46 50 45 45 48 44 45 45 50 45 45 50 45 45 50 45 45 50 45 45 50 45 45 50 45 43,6 50 45 45 50 45 45 45 50 45 45 50 45 45 50 45 45 50 45 45 50 45 45

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

719 684 693 828 776 798 932 945 983 998 1035 1103 1036 1351 1187 1199 1351 1350 1397 1657 1553 1596 1657 1660 1694 719 776 724 828 830 823 1035 1013 983 998 1106 1103 1112 1351 1350 1270 1470 1437 1442 1657 1660 1596 1799 1781 1705

57 2/QA2 58 2/QA3 46 2/QA4 58 2/QA3 59 2/QA3 52 2/QA4 59 2/QA3 60 2/QA4 53 1/QA2-1/QA3 44 1/QA3-1/QA4 59 2/QA3 60 2/QA4 54 1/Q5 60 2/QA4 60 1/QA4 54 2/QA3 60 2/QA4 61 1/QA5 54 1/Q2-1/Q3 61 1/Q5 62 2/QA3 55 2/QA4 61 1/Q5 62 2/QA3 55 2/QA4 57 2/QA2 59 2/QA3 52 2/QA4 58 2/QA3 59 2/QA3 53 2/QA4 59 2/QA3 60 2/QA4 50 1/Q2-1/Q3 41 1/Q3-1/Q4 59 2/QA3 60 2/QA4 54 1/Q5 60 2/QA4 61 1/Q5 54 2/QA3 60 2/QA4 61 1/Q2-1/Q3 55 1/Q3-1/Q4 61 1/Q5 62 2/QA3 55 2/QA4 61 1/Q5 62 1/Q3-1/Q4 55 2/QA4

2 2 2 2 2 2 2 2 2 2 2 2 1 2 1 2 2 1 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 2 1 2 2 2 2 1 2 2 1 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

no no no no no no no no yes yes no no yes no yes yes no yes yes yes yes yes yes yes yes no no no no no no no no yes yes no no yes no yes yes no yes yes yes yes yes yes yes yes

* Accessory to be provided in the order

Sound pressure measued in free field conditions, in cooling mode, at distance of 10m and direction factors = 2 in accordance with the ISO 3744 standard

334

refrigerant pipeworks kit *

control box type n/Type

ambient temperature C

condenser capacity kW

number of circuits of condenserless unit

Condenserless unit

Sound pressure dB(A)

speed regulator n

wiring connection

transducer n

Condenser

refrigerant

Combinations
number of remote condensers number of circuits of remote condenser condensing temperature C (request for) double coolig circuit *

WF2512E

WF2812E

WF3212E

WF3612E

WF4212E

WF4812E

WF5612E

WF6412E

WF2512AE

WF2812AE

WF3212AE

WF3612AE

WF4212AE

WF4812AE

WF5612AE

WF6412AE

1 1 1 1 1 1 1 1 2 1 1 2 1 2 2 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2

CDR8084BTD CVA8123BTD CVA8163STY CDR8103BTD CVA8124BTD CVA8163STD CVA8123BTD CVA8163BTD CDR8103BTY CVA8124BTD CVA8164BTD CDR8104BTY CVA8163BTD CDR8103BTD CVA8123STD CVA8164BTD CVA8104BTD CVA8143STD CDR8103BTD CVA8123BTD CVA8163STD CDR8104BTD CVA8143BTD CVA8164STD CDR8103BTD CVA8123BTD CVA8163STD CDR8103BTD CVA8124BTD CVA8163BTY CVA8123BTD CVA8164BTD CDR8103BTY CVA8163BTD CDR8103BTD CVA8123STD CVA8163BTD CDR8104BTD CVA8124STD CVA8164BTD CVA8104BTD CVA8143BTY CDR8103BTD CVA8124BTD CVA8163STD CDR8104BTD CVA8143BTD CVA8164BTY

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a R134a

triangle triangle star triangle triangle triangle triangle triangle star triangle triangle star triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle star triangle triangle star triangle triangle triangle triangle triangle triangle triangle triangle star triangle triangle triangle triangle triangle star

50 45 46 50 45 45 50 45 45 50 45 45 50 45 45 50 45 45 50 45 45 50 45 45 50 45 43.6 50 45 45 50 45 45 50 45 45 50 45 45 50 45 45 50 45 45 50 45 45

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

719 776 693 828 830 798 1035 1013 1036 1106 1103 1112 1351 1242 1199 1470 1437 1397 1657 1553 1596 1799 1781 1694 828 776 724 828 830 828 1035 1103 1036 1351 1242 1199 1351 1350 1270 1470 1437 1442 1657 1660 1596 1799 1781 1730

57 59 46 58 59 52 59 60 54 59 60 54 60 61 54 60 61 54 61 62 55 61 62 55 58 59 52 58 59 53 59 60 54 60 61 54 60 61 54 60 61 55 61 62 55 61 62 56

2/QA2 2/QA3 2/QA4 2/QA3 2/QA3 2/QA4 2/QA3 2/QA4 1/Q5 2/QA3 2/QA4 1/Q5 2/QA4 1/Q5 2/QA3 2/QA4 1/Q2 -1/Q3 1/Q2 -1/Q3 1/Q5 2/QA3 2/QA4 1/Q5 1/Q3-1/Q4 2/QA4 2/QA3 2/QA3 2/QA4 2/QA3 2/QA3 2/QA4 2/QA3 2/QA4 1/Q5 2/QA4 1/Q5 2/QA3 2/QA4 1/Q5 2/QA3 2/QA4 1/Q2 -1/Q3 1/Q3-1/Q4 1/Q5 2/QA3 2/QA4 1/Q5 1/Q3-1/Q4 2/QA4

2 2 2 2 2 2 2 2 1 2 2 1 2 1 2 2 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 1 2 1 2 2 1 2 2 2 2 1 2 2 1 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

no no no no no no no no yes yes yes yes no yes yes no yes yes yes yes yes yes yes yes no no no no no no no no yes no yes yes no yes yes no yes yes yes yes yes yes yes yes

* Accessory to be provided in the order

Sound pressure measued in free field conditions, in cooling mode, at distance of 10m and direction factors = 2 in accordance with the ISO 3744 standard

refrigerant pipeworks kit *

control box type n/Type

ambient temperature C

condenser capacity kW

number of circuits of condenserless unit

Condenserless unit

Sound pressure dB(A)

speed regulator n

wiring connection

transducer n

Condenser

refrigerant

335

Technical and dimensional data


Air ow rate Dimensions [mm] Connection IN Connection OUT

Model

Fans

CSE C 760 760 760 1310 1105 1105 1105 1105 1105 1105 2045 2045 2045 1340 1340 1340 1340 1340 1340 2500 2500 2500 2500 2500 2500 2500 3660 3660 3660 3660 3660 4820 4820 3543 3543 3543 3543 3543 3543 5208 5208 5208 3543 5208 5208 3543 5208 5208 3063 3063 4493 4493 2270 2270 2270 2270 3210 3210 3210 3210 3210 3210

CSEX3012BM CSEX3013BM CSEX3014SM CSEX3022SM CSEX5013STY CSEX5013STD CSEX5014SM CSEX5014EM CSEX5014STD CSEX5015STD CSEX5023STY CSEX5024BTY CSEX5025ETY CSEX6013ETD CSEX6014STY CSEX6014STD CSEX6014BTY CSEX6014BTD CSEX6015BTD CSEX6023ETD CSEX6023STD CSEX6023BTD CSEX6023BTY CSEX6024BTD CSEX6024STY CSEX6025BTD CSEX6033BTD CSEX6033ETD CSEX6033STY CSEX6033BTY CSEX6034BTD CSEX6043STY CSEX6044BTD CSEX8023STD CSEX8023BTY CSEX8023STD CSEX8023STY CSEX8024BTY CSEX8024BTD CSEX8033ETD CSEX8033STY CSEX8034BTD CSEX8043BTD CSEX8063BTD CSEX8063BTY CSEX8044BTD CSEX8064BTD CSEX8064STY CSEX9024BTD CSEX9026BTD CSEX9034BTD CSEX9036BTD CVRX8023BTD CVRX8023BTY CVRX8024BTD CVRX8024BTY CVRX8033BTD CVRX8033STD CVRX8033STY CVRX8033BTY CVRX8034BTD CVRX8034STD

[n] 1 1 1 2 1 1 1 1 1 1 2 2 2 1 1 1 1 1 1 2 2 2 2 2 2 2 3 3 3 3 3 4 4 2 2 2 2 2 2 3 3 3 4 6 6 4 6 6 2 2 3 3 2 2 2 2 3 3 3 3 3 3

[m3/h] 2500 2200 1400 3000 3900 5100 4750 3550 4850 4600 7800 11000 3500 4450 5000 6500 7350 9150 8700 8900 13500 19100 15500 18300 10000 17400 28650 13350 16050 28650 27450 21400 36600 28150 30200 28150 21550 28400 36850 25500 32650 55650 77500 117000 91200 73700 111300 60400 38700 35400 58050 53100 47500 37500 46000 36500 72000 52500 41000 57000 68500 50500

[nx mm] 1x16 1x16 1x18 1x18 1X28 1X28 1x28 1x28 1X28 1X28 1X35 1X35 1X35 1X28 1X28 1X28 1X28 1X28 1X35 1X35 1X35 1X35 1X35 1X42 1X42 1X42 1X48 1X48 1X48 1X48 1X48 1X48 1X54

[nx mm] 1x16 1x16 1x18 1x18 1X18 1X18 1x22 1x22 1X22 1X22 1x28 1x28 1x28 1X22 1X22 1X22 1X22 1X22 1X28 1X28 1X28 1X28 1X28 1X28 1X28 1X28 1X35 1X35 1X35 1X35 1X35 1X35 1X42

1X54 1X54 1X54 1X70 2x42 2x42 2x42 2x42 2x42 2x42 2x42 2x42 2x48 2x48

1X42 1X42 1X42 1X54 2x28 2x28 2x28 2x28 2x28 2x28 2x28 2x28 2x35 2x35

A 820 820 820 820 1060 1060 1060 1060 1060 1060 1060 1060 1060 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1340 1340 1340 1340 1340 1340 1340 1340 1340 1340 1340 1340 1340 1340 1340 1530 1530 1530 1530 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590

B 560 560 560 560 773 773 773 773 773 773 773 773 773 973 973 973 973 973 973 973 973 973 973 973 973 973 973 973 973 973 973 973 973 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1150 1374 1374 1374 1374 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100

CVR

1090

1000 B

336

Technical and dimensional data


Air ow rate Dimensions [mm] Connection IN Connection OUT Model CDR

Fans

B
C 4180 4180 4180 4180 5150 5150 5150 4180 4180 4180 5150 5150 5150 2270 3240 4210 4210 4210 4210 4210 4210 4210 5180 5180 5180 5180 5180 5180 5180 5180 5180 8100 8100 8700 8700 8700 8700 8700 8700 8700 8700 11200 11200 9950 9950 11200 11200 11200

CVRX8043BTD CVRX8043STY CVRX8044BTD CVRX8043ETD CVRX8053BTD CVRX8053STD CVRX8053ETD CVRX8043BTY CVRX8043ETY CVRX8053STY CVRX8054BTD CVRX8054BTY CVRX8054STY CDRX8043STD CDRX8064BTD CDRX8083BTD CDRX8083STD CDRX8083ETD CDRX8083STY CDRX8084BTD CDRX8084STD CDRX8084STY CDRX8103BTD CDRX8103BTY CDRX8103STD CDRX8103ETD CDRX8103STY CDRX8104BTD CDRX8104STD CDRX8104STY CDRX8104BTY CVA8103BTD CVA8104BTD CVA8123BTD CVA8123STD CVA8124BTD CVA8124STD CVA8143BTD CVA8143BTY CVA8143STD CVA8143ETD CVA8163STY CVA8163STD CVA8163BTD CVA8163BTY CVA8164BTD CVA8164BTY CVA8164STD

[n] 4 4 4 4 5 5 5 4 4 4 5 5 5 4 6 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 10 10 10 12 12 12 12 14 14 14 14 16 16 16 16 16 16 16

[m3/h] 96000 53500 91000 68200 115000 86000 55100 74000 44250 68000 115000 92000 66000 59000 115700 163600 117000 71700 86000 150000 107000 83000 204500 152000 145000 89700 108000 192700 140000 108000 108000 205000 19000 242000 170000 222000 162000 282000 218000 202000 122800 179300 230000 324000 145000 296000 234000 215000

[nx mm] 2x48 2x48 2x48 2x48 2x60 2x60 2x60 2x48 2x48 2x48 2x60 2x60 2x60 2x48 2x54 2x60 2x60 2x60 2x60 2x60 2x60 2x60 2x70 2x70 2x70 2x70 2x70 2x70 2x70 2x70 2x70 2x89 2x89 2x89 2x89 2x89 2x89 2x89 2x89 2x89 2x89 2x89 2x89 2x89 2x89 2x89 2x89 2x89

[nx mm] 2x35 2x35 2x35 2x35 2x42 2x42 2x42 2x35 2x35 2x35 2x42 2x42 2x42 2x35 2x42 2x48 2x48 2x48 2x48 2x48 2x48 2x48 2x54 2x54 2x54 2x54 2x54 2x54 2x54 2x54 2x54 2x64 2x64 2x64 2x64 2x64 2x64 2x64 2x64 2x64 2x64 2x64 2x64 2x64 2x64 2x64 2x64 2x64

A 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2105 2105 2105 2105 2105 2105 2105 2105 2105 2105 2105 2105 2105 2105 2105 2105 2105

B 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 2160 2160 2160 2160 2160 2160 2160 2160 2160 2160 2160 2160 2160 2160 2160 2160 2160 2160 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200

CVA

The technical data in this document is not binding. Aermec S.p.A. reserves the right to make any changes at any time deemed necessary for product improvement.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Telephone 0442633111 - Telefax 044293730 www.aermec.com

337

Cod.: SCONREUY.02 / 1111

WTE - WTR - WDR - WTS - WTA


Dry coolers

WTE

WTR-WDR

WTS

WTA

Features
WTE RANGE General features Design has privileged modularity, each unit is made up from standard sections, whose elements can be easily removed Parting from the WTE 563 for the 500 range, from the WTE 663 for the 630 range, models are found that are made up from two flanked units, thus making vertical installation impossible. All of the other models are designed for both horizontal and vertical installation. The support feet supplied can be used in both cases. To ease the connection of the electric system chillers, the fan motors are wired in the factory (excluding 350 diameter range) and connected to a junction box positioned on the collectors side and protected along with the latter by a lid that can be easily removed. Construction features They are designed for outdoor installation and therefore manufactured with technologies and materials that guarantee resistance to atmospheric agents Coils with staggered copper pipes and corrugated or mechanically expanded aluminium louvers. The coils are fixed to the shoulders in a way to prevent pipe breakage due to any vibrations. Iron collectors with GAS threading. Latest generation axial fans to guarantee silent functioning and high performance with IP54 protection rating: They are envisioned for D/Y connections and different polarities and allow continuous regulation of the speed via voltage reduction. Available versions: (B) basic (S) silent (E) Super silent. WTA RANGE General features Two exchangers positioned as W Two independent cooling circuits Two rows of fans with diameter of 800mm From 4 to 16 fans Separate ventilation compartments for each fan Construction features They are designed for outdoor installation and therefore manufactured with technologies and materials that guarantee resistance to atmospheric agents High efficiency louvred heat exchangers Latest generation axial fans to guarantee silent functioning and high performance with IP54 protection rating: The standard units are supplied with the fans wired onto the junction box. Air flow separator for each individual fan. Available versions: (BT) basic 6-pole (ST) silent 8-pole (ET) Super silent 12-pole WTR RANGE General features V exchangers configuration Two independent cooling circuits Low noise Two rows of fans with diameter of 800mm From 4 to 10 fans Construction features They are designed for outdoor installation and therefore manufactured with technologies and materials that guarantee resistance to atmospheric agents High efficiency louvred heat exchangers Latest generation axial fans to guarantee silent functioning and high performance with IP54 protection rating: The standard units are supplied with the fans wired onto the junction box. Air flow separator for each individual fan. Available versions: (BT) basic 6-pole (ST) silent 8-pole (ET) Super silent 12-pole WTS RANGE General features Two exchangers positioned as V Fans diameter 500 mm From 2 to 5 fans Separate ventilation compartments for each fan Construction features They are designed for outdoor installation and therefore manufactured with technologies and materials that guarantee resistance to atmospheric agents High efficiency louvred heat exchangers Latest generation axial fans to guarantee silent functioning and high performance with IP54 protection rating. The standard units are supplied with fans wired on junction box. Air flow separator for each individual fan. The extremely small dimensions allow installation in contained spaces, high output power per surface occupied Available versions: (BT) basic 4-pole (ST) silent 6-pole (ET) Super silent 8-pole WTR RANGE General features Two exchangers positioned as V Fans diameter 800 mm From 2 to 5 fans Separate ventilation compartments for each fan Construction features They are designed for outdoor installation and therefore manufactured with technologies and materials that guarantee resistance to atmospheric agents High efficiency louvred heat exchangers Latest generation axial fans to guarantee silent functioning and high performance with IP54 protection rating: The standard units are supplied with the fans wired onto the junction box. Air flow separator for each individual fan. The extremely small dimensions allow installation in contained spaces, high output power per surface occupied Available versions: (BT) basic 6-pole (ST) silent 8-pole (ET) Super silent 12-pole

338

Choosing the unit


Field configuration: 1 2 3 4 5 6 7 8 9 10 11 | | | | | | | | Code | [dm] fans | n rows | Power supply | | n fans motor Electrical Fluido Type connection Code: WTS-WTE-WTR-WTA-WDR Fluido: - Acqua o acqua glicolata con PS max 6 bar [dm] fans: 3 - 350 5 - 500 6 - 630 8 - 800 9 - 910 N fans: * - up 1 to 16 N rows: * - up 1to 6 Motor type: B - Standard S - Silenced E - Extra silenced Power suppluy: T - 400V/3/50Hz M - 230V/1/ 50Hz Electrical connection: D - Triangle - mono-phase

Technical and dimensional data


WTE

Model WTE WTE0312BM WTE 0313BM WTE0314BM WTE0322BM WTE0323BM WTE0324BM WTE0332BM WTE0333BM WTE0334BM WTE0342BM WTE0343BM WTE0344BM WTE0362BM WTE0363BM WTE0364BM WTE0312SM WTE0313SM WTE0314SM WTE0322SM WTE0323SM WTE0324SM WTE0332SM WTE0333SM WTE0334SM WTE0342SM WTE0343SM WTE0344SM WTE0362SM WTE0363SM WTE0364SM

wiring connec. Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase

Fans [dm] 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

Fan [n] 1 1 1 2 2 2 3 3 3 4 4 4 6 6 6 1 1 1 2 2 2 3 3 3 4 4 4 6 6 6

Rows [n] 2 3 4 3 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 3 4 2 3 4 2 3 4 2 3 4

air ow rate Power [m3/h] [kW] 2.500 4,6 2.200 6 2400 7,4 5000 9,2 4400 12 4800 15 7500 14 6600 18 7200 22 10000 18 8800 24 9600 30 15000 28 13200 38 14400 47 1500 1300 1400 3000 2600 2800 4500 3900 4200 6000 5200 5600 9000 7800 8400 3,6 4,4 5 7,4 9 10 11 14 16 15 18 20 24 28 32

Sound pressure dB(A) 36 36 36 39 39 39 41 41 41 42 42 42 44 44 44 26 26 26 29 29 29 31 31 31 32 32 32 34 34 34 48 48 48 51 51 51

A 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 820 1060 1060 1060 1060 1060 1060

Dimensions [mm] B 620 620 620 620 620 620 620 620 620 1200 1200 1200 1200 1200 1200 620 620 620 620 620 620 620 620 620 1200 1200 1200 1200 1200 1200 833 833 833 833 833 833

C 760 760 760 1310 1310 1310 1860 1860 1860 1310 1310 1310 1860 1860 1860 760 760 760 1310 1310 1310 1860 1860 1860 1310 1310 1310 1860 1860 1860 1105 1105 1105 2045 2045 2045

WTE0513 BT triangle 5 1 3 WTE0514 BT triangle 5 1 4 WTE0515 BT triangle 5 1 5 WTE0522 BT triangle 5 2 2 WTE0523 BT triangle 5 2 3 WTE0524 BT triangle 5 2 4 The performance refers to the following conditions: e Sound pressure measured in free field at a distance of 10m and directionality factor = 2;

7750 17 7400 20 7100 23 16000 26 15500 35 14800 42 - Ta = 25C - Twi = 40 C - Two = 35 C - Glyvol = 34%

339

Technical and dimensional data


WTE

Model WTE WTE0525BT WTE0533BT WTE0534BT WTE0535BT WTE0543BT WTE0544BT WTE0545BT WTE0563BT WTE0564BT WTE0565BT WTE0583BT WTE0584BT WTE0585BT WTE0513ST WTE0514ST WTE0515ST WTE0522ST WTE0523ST WTE0524ST WTE0525ST WTE0533ST WTE0534ST WTE0535ST WTE0543ST WTE0544ST WTE0545ST WTE0563ST WTE0564ST WTE0565ST WTE0583ST WTE0584ST WTE0585ST WTE0513ET WTE0514ET WTE0515ET WTE0522ET WTE0523ET WTE0524ET WTE0525ET WTE0533ET WTE0534ET WTE0535ET WTE0543ET WTE0544ET WTE0545ET WTE0563ET WTE0564ET WTE0565ET WTE0583ET WTE0584ET WTE0585ET WTE0513BM WTE0514BM WTE0515BM WTE0522BM WTE0523BM WTE0524BM WTE0525BM WTE0533BM

wiring connec. triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase

Fans [dm] 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

Fan [n] 2 3 3 3 4 4 4 6 6 6 8 8 8 1 1 1 2 2 2 2 3 3 3 4 4 4 6 6 6 8 8 8 1 1 1 2 2 2 2 3 3 3 4 4 4 6 6 6 8 8 8 1 1 1 5 2 2 2 3

Rows [n] 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 2 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 2 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 5 3 4 5 3

air ow rate Power [m3/h] [kW] 14200 47 23250 54 22200 63 21300 70 31000 71 29600 83 28400 96 46500 108 44400 126 42600 140 62000 142 59200 166 56800 192 5100 13 4850 11 4600 17 10650 21 10200 27 9700 32 9200 34 15300 41 14550 48 13800 52 20400 56 19400 64 18400 69 30600 82 29100 96 27600 104 40800 112 38800 129 36800 139 3350 10 3200 11 3000 12 7300 17 6700 21 6400 24 6000 25 10050 31 9600 36 9000 38 13400 42 12800 48 12000 50 20100 63 19200 72 18000 75 26800 84 25600 97 24000 100 7360 7030 6745 15200 14720 14060 13490 22080 16 20 22 26 34 41 45 52

Sound pressure dB(A) 51 53 53 53 54 54 54 56 56 56 57 57 57 38 38 38 41 41 41 41 43 43 43 44 44 44 46 46 46 47 47 47 32 32 32 35 35 35 35 37 37 37 38 38 38 40 40 40 41 41 41 45 45 45 48 48 48 48 50

A 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060

Dimensions [mm] B 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833

C 2045 2985 2985 2985 3925 3925 3925 2985 2985 2985 3925 3925 3925 1105 1105 1105 2045 2045 2045 2045 2985 2985 2985 3925 3925 3925 2985 2985 2985 3925 3925 3925 1105 1105 1105 2045 2045 2045 2045 2985 2985 2985 3925 3925 3925 2985 2985 2985 3925 3925 3925 1105 1105 1105 2045 2045 2045 2045 2985

The performance refers to the following conditions: e Sound pressure measured in free field at a distance of 10m and directionality factor = 2;

- Ta = 25C - Twi = 40 C - Two = 35 C - Glyvol = 34%

340

Technical and dimensional data


Model WTE WTE0534BM WTE0535BM WTE0543BM WTE0544BM WTE0545BM WTE0563BM WTE0564BM WTE0565BM WTE0583BM WTE0584BM WTE0585BM WTE0513SM WTE0514SM WTE0515SM WTE0522SM WTE0523SM WTE0524SM WTE0525SM WTE0533SM WTE0534SM WTE0535SM WTE0543SM WTE0544SM WTE0545SM WTE0563SM WTE0564SM WTE0565SM WTE0583SM WTE0584SM WTE0585SM WTE0513 EM WTE0514 EM WTE0515 EM WTE0522 EM WTE0523 EM WTE0524 EM WTE0525 EM WTE0533 EM WTE0534 EM WTE0535 EM WTE0543 EM WTE0544 EM WTE0545 EM WTE0563 EM WTE0564 EM WTE0565 EM WTE0583 EM WTE0584 EM WTE0585 EM WTE0613BT WTE0614BT WTE0615BT WTE0623BT WTE0624BT WTE0625BT WTE0633BT WTE0634BT WTE0635BT WTE0643BT WTE0644BT WTE0645BT WTE0663BT WTE0664BT WTE0665BT WTE0683BT WTE0684BT WTE0685BT WTE0613ST WTE0614ST WTE0615ST wiring connec. Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase Monophase triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle Fans [dm] 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Fan [n] 3 3 4 4 4 6 6 6 8 8 8 1 1 1 2 2 2 2 3 3 3 4 4 4 6 6 6 8 8 8 1 1 1 2 2 2 2 3 3 3 4 4 4 6 6 6 8 8 8 1 1 1 2 5 2 3 3 3 4 4 4 6 6 6 8 8 8 1 1 1 Rows [n] 4 5 3 4 5 3 4 5 3 4 5 3 4 5 2 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 2 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 air ow rate Power [m3/h] [kW] 21090 61 20235 67 29440 69 28120 80 26980 92 44160 104 42180 122 40470 135 58880 137 56240 160 53960 185 5000 4750 4510 10440 10000 9500 9020 15000 14250 15350 20000 19000 18040 30000 28500 27060 40000 38000 36080 3720 3550 3330 8100 7440 7100 6660 11160 10650 9990 14880 14200 13320 22320 21300 19980 29760 28400 26640 9550 9150 8700 19100 18300 17400 28650 27450 26100 38200 36600 34800 57300 54900 52200 76400 73200 69600 6750 6500 6200 13 15 17 21 27 31 34 40 47 51 55 65 68 80 95 102 111 127 136 11 12 13 18 22 25 27 34 38 41 45 51 55 68 76 82 90 102 109 23 28 31 48 56 62 74 85 93 98 113 123 147 171 186 195 226 246 19 22 24 Sound pressure dB(A) 50 50 51 51 51 53 53 53 54 54 54 35 35 35 38 38 38 38 40 40 40 41 41 41 43 43 43 44 44 44 32 32 32 35 35 35 35 37 37 37 38 38 38 40 40 10 41 41 41 49 49 49 52 52 52 54 54 54 55 55 55 57 57 57 58 58 58 42 42 42 A 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 Dimensions [mm] B 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 833 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 C 2985 2985 3925 3925 3925 2985 2985 2985 3925 3925 3925 1105 1105 1105 2045 2045 2045 2045 2985 2985 2985 3925 3925 3925 2985 2985 2985 3925 3925 3925 1105 1105 1105 2045 2045 2045 2045 2985 2985 2985 3925 3925 3925 2985 2985 2985 3925 3925 3925 1340 1340 1340 2500 2500 2500 3660 3660 3660 4820 4820 4820 3660 3660 3660 4820 4820 4820 1340 1340 1340

The performance refers to the following conditions: e Sound pressure measured in free field at a distance of 10m and directionality factor = 2;

- Ta = 25C - Twi = 40 C - Two = 35 C - Glyvol = 34%

341

Technical and dimensional data


WTE

Model WTE WTE0623ST WTE0624ST WTE0625ST WTE0633ST WTE0634ST WTE0635ST WTE0643ST WTE0644ST WTE0645ST WTE0663ST WTE0664ST WTE0665ST WTE0683ST WTE0684ST WTE0685ST WTE0613ET WTE0614ET WTE0615ET WTE0623ET WTE0624ET WTE0625ET WTE0633ET WTE0634ET WTE0635ET WTE0643ET WTE0644ET WTE0645ET WTE0663ET WTE0664ET WTE0665ET WTE0683ET WTE0684ET WTE0685ET WTE0913BT WTE0914BT WTE0916BT WTE0923BT WTE0924BT WTE0926BT WTE0933BT WTE0934BT WTE0936BT WTE0943BT WTE0944BT WTE0946BT WTE0963BT WTE0964BT WTE0966BT WTE0913ST WTE0914ST WTE0916ST WTE0923ST WTE0924ST WTE0926ST WTE0933ST WTE0934ST WTE0936ST WTE0943ST

wiring connec. triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle

Fans [dm] 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9

Fan [n] 2 2 2 3 3 3 4 4 4 6 6 6 8 8 8 1 1 1 2 2 2 3 3 3 4 4 4 6 6 6 8 8 8 1 1 1 2 2 2 3 3 3 4 4 4 6 6 6 1 1 1 2 2 2 3 3 3 4

Rows [n] 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 6 3 4 6 3 4 6 3 4 6 3 4 6 3 4 6 3 4 6 3 4 6 3

air ow rate Power [m3/h] [kW] 13500 38 13000 45 12400 48 20250 58 19500 67 18600 73 27000 77 26000 88 24800 98 40500 116 39000 134 37200 147 54000 154 52000 177 49600 196 4450 4300 4050 8900 8600 8100 13350 12900 12150 17800 17200 16200 26700 25800 24300 35600 34400 32400 20400 19350 17700 40800 38700 35400 61200 58050 53100 81600 77400 70800 122400 116100 106200 15000 14050 12900 30000 28100 25800 45000 42150 38700 60000 14 16 17 29 33 35 44 50 53 59 67 69 89 100 105 118 133 139 47 55 65 96 111 133 144 168 195 191 223 267 289 335 390 39 45 51 78 91 104 118 133 158 156

Sound pressure dB(A) 45 45 45 47 47 47 48 48 48 50 50 50 51 51 51 32 32 32 35 35 35 37 37 37 38 38 38 40 40 40 41 41 41 56 56 56 59 59 59 61 61 61 62 62 62 64 64 64 50 50 50 53 53 53 55 55 55 56

A 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530

Dimensions [mm] B 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1033 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434

C 2500 2500 2500 3660 3660 3660 4820 4820 4820 3660 3660 3660 4820 4820 4820 1340 1340 1340 2500 2500 2500 3660 3660 3660 4820 4820 4820 3660 3660 3660 4820 4820 4820 1633 1633 1633 3063 3063 3063 4493 4493 4493 3063 3063 3063 4493 4493 4493 1633 1633 1633 3063 3063 3063 4493 4493 4493 3063

The performance refers to the following conditions: e Sound pressure measured in free field at a distance of 10m and directionality factor = 2;

- Ta = 25C - Twi = 40 C - Two = 35 C - Glyvol = 34%

342

Technical and dimensional data


Model WTE WTE0944ST WTE0946ST WTE0963ST WTE0964ST WTE0966ST WTE0913ET WTE0914ET WTE0916ET WTE0923ET WTE0924ET WTE0926ET WTE0933ET WTE0934ET WTE0936ET WTE0943ET WTE0944ET WTE0946ET WTE0963ET WTE0964ET WTE0966ET wiring connec. triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle Fans [dm] 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Fan [n] 4 4 6 6 6 1 1 1 2 2 2 3 3 3 4 4 4 6 6 6 Rows [n] 4 6 3 4 6 3 4 6 3 4 6 3 4 6 3 4 6 3 4 6 air ow rate Power [m3/h] [kW] 56200 183 51600 208 90000 235 84300 267 77400 316 9200 8600 7800 18400 17200 15600 27600 25800 23400 36800 34400 31200 55200 51600 46800 28 32 35 57 65 70 87 96 106 115 129 141 174 193 212 Sound pressure dB(A) 56 56 58 58 58 38 38 38 41 41 41 43 43 43 44 44 44 46 46 46 A 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 1530 Dimensions [mm] B 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 1434 C 3063 3063 4493 4493 4493 1633 1633 1633 3063 3063 3063 4493 4493 4493 3063 3063 3063 4493 4493 4493

The performance refers to the following conditions: e Sound pressure measured in free field at a distance of 10m and directionality factor = 2;

- Ta = 25C - Twi = 40 C - Two = 35 C - Glyvol = 34%

WTS

Model WTS WTS0523BT WTS0524BT WTS0533BT WTS0534BT WTS0543BT WTS0544BT WTS0553BT WTS0554BT WTS0523ST WTS0524ST WTS0533ST WTS0534ST WTS0543ST WTS0544ST WTS0553ST WTS0554ST WTS0523ET WTS0524ET WTS0533ET WTS0534ET WTS0543ET WTS0544ET WTS0553ET WTS0554ET

wiring connec. triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle

Fans [dm] 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

Fan [n] 2 2 3 3 4 4 5 5 2 2 3 3 4 4 5 5 2 2 3 3 4 4 5 5

Rows [n] 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4

air ow rate Power [m3/h] [kW] 15.800 46 15.200 51 23700 69 22800 77 31600 92 30400 103 39500 115 38000 128 10400 10000 15600 15000 20800 20000 26000 25000 6800 6500 10200 9750 13600 13000 17000 16250 38 41 57 62 76 82 95 103 27 29 41 44 54 58 66 71

Sound pressure dB(A) 51 51 53 53 54 54 55 55 41 41 43 43 44 44 45 45 34 34 36 36 37 37 38 38

A 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065 1065

Dimensions [mm] B 780 780 780 780 780 780 780 780 780 780 780 780 780 780 780 780 780 780 780 780 780 780 780 780

C 1610 1610 2265 2265 2920 2920 3575 3575 1610 1610 2265 2265 2920 2920 3575 3575 1610 1610 2265 2265 2920 2920 3575 3575

The performance refers to the following conditions: e Sound pressure measured in free field at a distance of 10m and directionality factor = 2;

- Ta = 25C - Twi = 40 C - Two = 35 C - Glyvol = 34%

343

Technical and dimensional data


WTR

Model WTR WTR0823BT WTR0824BT WTR0833BT WTR0834BT WTR0843BT WTR0844BT WTR0853BT WTR0854BT WTR0823ST WTR0824ST WTR0833ST WTR0834ST WTR0843ST WTR0844ST WTR0853ST WTR0854ST WTR0823ET WTR0833ET WTR0843ET WTR0853ET

wiring connec. triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle

Fans [dm] 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

Fan [n] 2 2 3 3 4 4 5 5 2 2 3 3 4 4 5 5 2 3 4 5

Rows [n] 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 3 3 3

air ow rate Power [m3/h] [kW] 46.000 131 45.000 150 70000 204 66000 229 92000 275 88500 307 114000 338 112000 390 34000 32000 50500 48000 67000 63000 83500 80000 21100 31750 42300 52900 112 122 167 183 223 240 279 298 79 121 162 203

Sound pressure dB(A) 51 51 53 53 54 54 55 55 43 43 45 45 46 46 47 47 33 35 36 37

A 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590 1590

Dimensions [mm] B 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100

C 2270 2270 3210 3210 4180 4180 5150 5150 2270 2270 3210 3210 4180 4180 5150 5150 2270 3210 4180 5150

The performance refers to the following conditions: e Sound pressure measured in free field at a distance of 10m and directionality factor = 2; WTA

- Ta = 25C - Twi = 40 C - Two = 35 C - Glyvol = 34%

Model WTA WTA0843BT WTA0844BT WTA0863BT WTA0864BT WTA0883BT WTA0884BT WTA08103BT WTA08104BT WTA08123BT WTA08124BT WTA08143BT WTA08144BT WTA08163BT WTA08164BT

wiring connec. triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle

Fans [dm] 8 8 8 8 8 8 8 8 8 8 8 8 8 8

Fan [n] 4 4 6 6 8 8 10 10 12 12 14 14 16 16

Rows [n] 3 4 3 4 3 4 3 4 3 4 3 4 3 4

air ow rate Power [m3/h] [kW] 84.000 283 82.000 314 122000 391 112000 422 165000 525 153000 569 205000 674 190000 736 242000 782 222000 844 282000 916 258000 991 324000 1050 296000 1138

Sound pressure dB(A) 54 54 56 56 57 57 58 58 59 59 59 59 60 60

A 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090

Dimensions [mm] B 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200

C 3250 3250 3850 3850 5100 5100 8100 8100 8700 8700 9950 9950 11200 11200

The performance refers to the following conditions: e Sound pressure measured in free field at a distance of 10m and directionality factor = 2;

- Ta = 25C - Twi = 40 C - Two = 35 C - Glyvol = 34%

344

Technical and dimensional data


Model WTA WTA0843ST WTA0844ST WTA0863ST WTA0864ST WTA0883ST WTA0884ST WTA08103ST WTA08104ST WTA08123ST WTA08124ST WTA08143ST WTA08144ST WTA08163ST WTA08164ST WTA0843 ET WTA0863 ET WTA0883 ET WTA08103 ET WTA08123 ET WTA08143 ET WTA08163 ET wiring connec. triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle Fans [dm] 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Fan [n] 4 4 6 6 8 8 10 10 12 12 14 14 16 16 4 6 8 10 12 14 16 Rows [n] 3 4 3 4 3 4 3 4 3 4 3 4 3 4 6 3 3 3 3 3 3 air ow rate Power [m3/h] [kW] 62000 220 60000 236 87000 297 82000 316 116000 398 110000 424 147000 517 142000 551 170000 593 162000 632 202000 694 187000 739 230000 796 215000 847 37400 52500 70300 89900 105100 122800 140600 159 218 292 377 436 510 584 Sound pressure dB(A) 46 46 48 48 49 49 50 50 51 51 51 51 52 52 36 38 39 40 41 41 42 A 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 2090 Dimensions [mm] B 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 C 3250 3250 3850 3850 5100 5100 8100 8100 8700 8700 9950 9950 11200 11200 3250 3850 5100 8100 8700 9950 11200

The performance refers to the following conditions: e Sound pressure measured in free field at a distance of 10m and directionality factor = 2;

- Ta = 25C - Twi = 40 C - Two = 35 C - Glyvol = 34%

WDR

Model WDR WDR0843BT WDR0844BT WDR0863BT WDR0864BT WDR0883BT WDR0884BT WDR08103BT WDR08104BT WDR0843ST WDR0844ST WDR0863ST WDR0864ST WDR0883ST WDR0884ST WDR08103ST WDR08104ST WDR0843ET WDR0863ET WDR0883ET WDR08103ET

wiring connec. triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle triangle

Fans [dm] 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

Fan [n] 4 4 6 6 8 8 10 10 4 4 6 6 8 8 10 10 4 6 8 10

Rows [n] 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 3 3 3

air ow rate Power [m3/h] [kW] 77.100 232 70.400 254 115700 349 105500 381 154200 467 140700 508 192800 583 176000 635 55000 50000 82000 74500 110000 99000 136000 125000 33350 49900 66600 83250 188 203 286 301 384 405 476 507 137 206 274 343

Sound pressure dB(A) 54 54 56 56 57 57 58 58 46 46 48 48 49 49 50 50 36 38 39 40

A 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150

Dimensions [mm] B 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850

C 2270 2270 3240 3240 4210 4210 5180 5180 2270 2270 3240 3240 4210 4210 5180 5180 Cod.: SDRYCOOLERUI.02 / 1201 2270 3240 4210 5180

The performance refers to the following conditions: e Sound pressure measured in free field at a distance of 10m and directionality factor = 2;

- Ta = 25C - Twi = 40 C - Two = 35 C - Glyvol = 34%

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

345

DMP

Recessed dehumidifier for floor systems

R134a

White: front panel: RAL 9010

Features
Components: DMP 20: Monobloc dehumidifier unit, recessed inside the formwork. - electrostatically pre-charged air filter; - condensate drip tray; - hermetic compressor assembled on rubber The DMP dehumidifiers can be integrated peranti-vibration mounts; fectly in residential and tertiary environments - condensing and evaporating coils realised in with: copper pipes and aluminium louvers; - floor systems; - pre-cooling coil: to improve the dehumidifica Main features: - vertical installation recessed in the wall; - silenced functioning; - small electric consumption; - high dehumidification efficiency. tion efficiency of the unit; - post-cooling coil: to control the temperature of the outlet air and send thermally neutral air to the room; - centrifugal flow fan with uneven pitch rotors for silent functioning; - adjustment circuit board with remote control panel. - Refrigerant gas: R134a.

Accessories
DMP 20GL: OBLIGATORY ACCESSORY -Front closure panel with external frame: realised in polyurethane powder painted galvanised steel (colour RAL 9010). Made up from a frame and panel with air recovery and flow grid in anodised aluminium. -Formwork: In galvanised steel, it allows unit installation in niche. The formwork has appro- rooms heated by the radiant system reaching priate fins for correct fixing to the wall and is normal working conditions. prepared with openings for electric and hydraulic connections; In the winter season the DMP dehumidifier can be used to accelerate the temperature of the

346

Technical data
Mod. Nominal dehumidification capacity (1) Nominal input power (1) Nominal input current (1) Dehumidification capacity (2) Input power (2) Heating capacity produced - normal working conditions in heating mode (3) Input power (3) Maximum current absorbed Peak current Nominal water flow rate Pressure drop
l/24h W A l/24h W W W A A l/h kPa m3/h (min.) Air flow rate m3/h (max.) dB [A] kg

e Sound Pressure Weight

DMP 20 20 340 2,3 49 390 1010 25 2,5 4 170 7 200 300 380 33 36

The performance refers to the following conditions: Dehumidification (1) = Nominal conditions (min. fan speed) Room air temperature: 26C Relative humidity: 65% Water input temperature: 15C = Maximum conditions (min. fan speed) Room air temperature: 35C Relative humidity: 80% Water input temperature: 15C Heating (3) = Rapid heating at normal conditions (min. fan speed) Room air temperature: 15C Water input temperature: 35C

- - - (2) - - -

Power supply voltage = 230V/1/50Hz. Sound pressure measured in free field with directionality factor Q=2 at a distance of 1 m (minimum fan speed). In compliance with the ISO 3746 - -

Dimensional data (mm)


C

DMP 20
B

DMP 20 Monobloc dehumidifier unit External frame 678 843 8

B DMP 20 GL
Front panel 596 761 18 Formwork 606 771 227

A
Height Width Depth [mm] (A) [mm] (B) [mm] (C)

Monobloc dehumidifier unit

590 750 210

DMP 20GL
C B B B B B B C

A
Cod.: SDMPUY.01 / 0903

External frame

C B

Front panel

C B

Formwork C

C B

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

347

04

PRELIMINARY

SI
R410A

Split system air conditioner and heat pump Wall mounted monosplit with capacity from 2.6 a 6.45kW DC Inverter Technology Air ioniser standard

NEW N! DESIG

Seasonal Energy Efficiency See Technical data

SI_E

Regulation (EU) N. 206/2012 Delegated Regulation (EU) N. 626/2011

SI_C

Characteristics
Available in 4 different capacity sizes. Refrigerant R410A Heat pump operation with reversible refrigerant cycle and defrost control Tangential type fan with 4 speeds: - 3 speeds directly selected (Minimum, Medium, Maximum) - One Super High speed when the Rapid Cooling/Heating (TURBO) function is activated, to achieve the required temperature as quickly as possible DC Inverter rotary compressor Extremely low noise operation Microprocessor control Infrared remote controller with liquid crystal display to control all functions Emergency control possibility if the remote controller batteries are flat (Button AUTO on internal unit) Front panel display showing operating modes and temperature. The display can be activated or deactivated from the remote controller Motorised deflector louvres controlled by the (LIGHT) remote controller to vertically adjust the dis Timer to programme clock functions (switch charge air, with 5 xed positions or oating on or off) (SWING) Operating modes: Cooling, Heating, Dehu- Flare type refrigerant connections midication, Automatic or Ventilation Only Simple installation and maintenance Air ioniser standard Night-time Health function (SLEEP) Energy Saving function Rapid Cooling/Heating function (TURBO) Extended Ventilation (X-FAN) function prevents the growth of mould in the internal unit during Cooling and Dehumidication Modes Intelligent pre-heat function to prevent jets of cold air (Heating Mode) Auto-diagnostic function Auto-Restart function after a power cut External unit defrost function External unit with condensate connection Cleanable air filter Horizontally adjustable air discharge louvres

350

PRELIMINARY
Technical data
Internal Unit External Unit Cooling capacity Power input SEER Energy efficiency class Condensate rate Heating capacity Power input SCOP Energy efficiency class Power input nominal * Airflow rate (SI_E) Sound pressure max (SI_E) Sound pressure max (SI_C) Compressor Max line length Max elevation change (Internal - external unit) Refrigerant connections Refrigerant lines Power supply SI090E SI090C 2600 870 5,6 A+ 0,8 3000 900 3,8 A 1550 600/520/370/280 38 51 15 10 1/4 3/8" 6,35 (1/4) 9,52 (3/8) SI120E SI180E SI120C SI180C 3500 5275 1150 1600 5,1 5,4 A A 1,4 1,8 3800 5570 1100 1750 3,8 3,8 A A 1650 2650 680/560/410/300 800/680/560/460 39 44 53 55 Rotary DC Inverter 20 25 10 10 SI240E SI240C 6450 2180 5,1 A 2 7000 2220 3,8 A 2800 1000/800/700/550 47 58 25 10 1/4 5/8 6,35 (1/4) 15,9 (5/8) W (nominal) W (nominal)

l/h W (nominal) W (nominal)

W m3/h dB(A) dB(A) m m liquid gas mm (inch) liquid mm (inch) gas V ~ Hz

1/4 1/4 3/8" 1/2 6,35 (1/4) 6,35 (1/4) 9,52 (3/8) 12,7 (1/2) 230V ~ 50Hz

Sound pressure measured at 1m distance from front in semi-anechoic chamber * In accordance with Standard EN-60335 Performances in accordance with Standards EN-14511 and EN-14825 Cooling: Ambient air temperature 27C db ; 19C wb External air temperature 35C Maximum speed Refrigerant line length 5m Heating: Ambient air temperature External air temperature Maximum speed Refrigerant line length 5m

- - - -

- - - -

20C 7C db ; 6C wb

Dimensional data (mm)

SI_C

SI_E

C C

SI 090E Height Width Depth Weight A B C kg 283 770 201 8 120E 283 770 201 9 180E 305 865 215 12 240E 315 1007 219 14,5 090C 540 776 320 28 120C 540 848 320 30

SI 180C 700 955 396 46 240C 790 980 427 55,5

Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

351

Cod.: SSIUY.00P / 1301

PRELIMINARY

HWI
R410A

Split system air conditioner and heat pump Wall mounted monosplit with capacity from 2.6 to 6.45kW DC Inverter Technology Air ioniser standard

HWI_E Seasonal Energy Efficiency See Technical data

Regulation (EU) N. 206/2012 Delegated Regulation (EU) N. 626/2011

HWI_C

Characteristics
Available in 4 different capacity sizes Refrigerant R410A Heat pump operation with reversible refrigerant cycle and defrost control Tangential type fan with 4 speeds: - 3 speeds directly selected (Minimum, Medium, Maximum) - One Super High speed when the Rapid Cooling/Heating (TURBO) function is activated, to achieve the required temperature as quickly as possible DC Inverter rotary compressor Extremely low noise operation Microprocessor control Infrared remote controller with backlit liquid crystal display to control all functions Emergency control possibility if the remote controller batteries are flat (Button AUTO on internal unit) Front panel display showing operating modes and temperature. The display can be activated or deactivated from the remote controller (LIGHT) Clock on remote controller Timer to programme clock functions (switch on and/or off) Operating modes: Cooling, Heating, Dehumidication, Automatic or Ventilation Only Air ioniser standard Night-time Health function (SLEEP) Energy Saving function Rapid Cooling/Heating function (TURBO) Personal Climate (I FEEL) function allows the user to have around him the desired climate through the internal sensor of the remote controller Extended Ventilation (X-FAN) function prevents the growth of mould in the internal unit during Cooling and Dehumidication Modes Antifreeze function prevents the internal space temperature dropping below 8C during the winter period Intelligent pre-heat function to prevent jets of cold air (Heating Mode) Auto-diagnostic function Auto-Restart function after a power cut External unit defrost function External unit with condensate connection Cleanable air filter Horizontally adjustable air discharge louvres Motorised deflector louvres controlled by the remote controller to vertically adjust the discharge air, with 8 xed positions or oating (SWING) Flare type refrigerant connections Simple installation and maintenance

352

PRELIMINARY
Technical data
Internal Unit External Unit Cooling capacity Power input SEER Energy efficiency class Condensate rate Heating capacity Power input SCOP Energy efficiency class Power input nominal * Airflow rate (HWI_E) Sound pressure max (HWI_E) Sound pressure max (HWI_C) Compressor Max line length Max elevation change (Internal - external unit) Refrigerant connections Refrigerant lines Power supply HWI091E HWI091C 2600 720 6,4 A++ 0,8 2750 720 4,0 A+ 1550 650/500/400/300 48 53 20 10 1/4 3/8" 6,35 (1/4) 9,52 (3/8) HWI121E HWI121C 3500 1100 6,4 A++ HWI181E HWI181C 5275 1620 5,6 A+ HWI241E HWI241C 6450 1940 5,8 A+ 2,0 6450 1910 3,8 A 3050 1000/800/700/600 49 60 25 10 1/4 5/8 6,35 (1/4) 15,9 (5/8) W W

l/h W W

W m3/h dB(A) dB(A) m m liquid gas mm (inch) liquid mm (inch) gas V ~ Hz

1,4 1,8 3650 5275 1100 1600 3,8 3,8 A A 1580 2500 650/500/400/300 850/780/650/500 48 47 53 55 Rotary DC Inverter 20 25 10 10

1/4 1/4 3/8" 1/2 6,35 (1/4) 6,35 (1/4) 9,52 (3/8) 12,7 (1/2) 230V ~ 50Hz

Sound pressure measured at 1m distance from front in semi-anechoic chamber * In accordance with Standard EN-60335 Performances in accordance with Standards EN-14511 and EN-14825 - - - - Cooling: Ambient air temperature 27C db ; 19C wb External air temperature 35C Maximum speed Refrigerant line length 5m - - - - Heating: Ambient air temperature External air temperature Maximum speed Refrigerant line length 5m 20C 7C db ; 6C wb

Dimensional data (mm)

HWI_E
A A B C

HWI_C

C B

HWI 091E Height Width Depth Weight A B C kg 275 845 180 10 121E 275 845 180 10 181E 298 945 208 13 241E 315 1018 223 15,5 091C 540 798 320 30 121C 540 848 320 33

HWI 181C 700 955 396 46 241C 790 980 427 62,5

Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

353

Cod.: SHWI1UY.00P / 1301

HWI
R410A

Split system air conditioners and heat pumps Wall installation with 2.5 to 6.45 kW power output with Inverter

HWI_E

HWI C

Features
Available in 4 sizes with different potentiality R410A refrigerant gas Heat pump functioning with reverse cooling cycle and defrost control 4 speed tangential fan: - 3 speeds directly selectable (Minimum, Medium, Maximum) - A super high speed when the "Turbo" function is activated to reach the desired temperature as quickly as possible DC Inverter rotary compressor Silent functioning Microprocessor control Infrared ray remote control with liquid crystal display for checking all functions Possibility of emergency control if remote control batteries are at (AUTO key in indoor unit) LCD display on front panel viewing operating modes and temperature (the display can be activated and deactivated with the remote control) Clock on remote control Timer for programming hourly functioning (switch-on and/or switch-off) Functioning mode: Cooling, Heating, Dehumidication, Automatic and Fan only Night time well-being (SLEEP) function Energy saving function Quick heating function (Turbo) Quick cooling function (Turbo) Customised climate function (I FEEL) which by activating the internal probe of the remote control, allows the user to be surrounded by the climate he desires Prolonged ventilation program "Antifreeze" function prevents the indoor temperature from dropping below 8C during winter Smart preheating function to prevent cold air jets (Heating mode) Mould prevention function in the indoor unit Self-diagnostics function Auto-restart function after a power cut Outdoor unit defrost function Outdoor unit with fitting to drain condensation Regenerative air filter Air flow louvered fins with horizontal adjustment facility Powered deflector louvers, which can be activated by remote control to direct the ow air vertically, with 8 xed or oating (Swing) positions Refrigerant lines with flared connections Easy installation and maintenance

354

Technical data
Indoor unit Outdoor unit Cooling capacity Total input power Total absorption EER Humidity removed Heating capacity Total input power Total absorption COP Rated Power Input * Rated Current * Air ow (HWI_E) Sound pressure (HWI_E) Sound pressure (HWI_C) Compressor Lines max length (total) Maximum height difference (indoor - outdoor unit) Refrigerant connections Refrigerant lines W (nominal) W (min-max) W (nominal) W (min-max) A (nominal) l/h W (nominal) W (min-max) W (nominal) W (min-max) A (nominal) W A m3/h dB(A) dB(A) m m liquid gas mm (inch) liquid mm (inch) gas HWI090E HWI090C 2500 500/3200 623 280/1200 2.76 4.01 0.8 2750 800/3500 669 310/1350 2.97 4.11 1550 5.88 600/500/400/300/43/40/38/35/53 Rotary Inverter 15 10 1/4 3/8" 6.35 (1/4) 9.52 (3/8) HWI120E HWI120C 3500 950/4000 960 350/1250 4.50 3.64 1.4 3750 880/4300 1010 340/1360 4.60 3.71 1480 6.00 600/500/400/300/45/42/39/36/55 Rotary Inverter 20 10 1/4 3/8" 6.35 (1/4) 9.52 (3/8) HWI180E HWI180C 5300 900/6200 1560 330/2300 6.92 3.40 1.8 5800 950/7500 1600 350/2700 7.10 3.63 2700 11.98 850/780/650/500/45/42/37/33 56 Rotary Inverter 25 10 1/4 1/2 6.35 (1/4) 12.7 (1/2) HWI240E HWI240C 6450 1400/7000 2010 350/2600 8.91 3.21 2.0 6700 1200/8000 1855 350/2700 8.22 3.61 2750 12.20 1000/800/700/600/49/44/39/34 56 Rotary Inverter 25 10 1/4 5/8 6.35 (1/4) 15.9 (5/8)

Electric power supply = 230V ~ 50Hz Sound pressure measured in a semi-anechoic chamber at 1m distance from the unit front * In accordance with EN-60335 standard Performance data in accordance with EN-14511 standard Cooling: - - - - Internal air temperature 27C D.B. ; 19C W.B. External air temperature 35C Maximum speed Refrigerant line length 5m - - - - Heating: Internal air temperature 20C External air temperature 7C D.B. ; 6C W.B. Maximum speed Refrigerant line length 5m

Dimensions (mm)

A A B C

HWI_E HWI_C
B C

HWI 090 E Height Width Depth Net weight A B C kg 275 845 180 10 120 E 275 845 180 10 180 E 298 945 208 13 240 E 315 1018 223 15.5 090 C 540 776 320 32 120 C 540 848 320 33

HWI 180 C 700 955 396 48 240 C 700 955 396 53

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

355

Cod.: SHWIUY.02 / 1206

HW
R410A

Split system air conditioners and heat pumps Ductable installation with capacities from 2.6 up to 6.6 kW

NEW N! DESIG

HW_E

HW C

Features
Available in 4 sizes of different capacity R410A Refrigerant gas Heat pump functioning with reverse cooling cycle and defrost control Indoor unit equipped with tangential fan with 4-speed motor: - 3 speeds can be selected directly - One ultra high speed available on activation of the TURBO function to obtain the required temperature as quickly as possible Rotary compressor Very quiet operation Microprocessor control Infrared remote control with backlit liquid crystalscreen for controlling all the functions Function"AUTO" for automatic selection of speed Front panel on display at the indoor unit and features LEDs to indicate the operating mode (The display can be turned on and off with the remote control) Clock on the remote control Timer for programming switch-on and/or switch-off Operating modes: Cooling, Heating, Dehumidification, Automatic and Fan only Sleep programme Auto-restart function Rapid heating function (Turbo) Rapid cooling function (Turbo) IFEEL function: used to activate the room temperature sensor inside the remote control to optimise indoor comfort Program prolonged ventilation (X-FAN), function to prevent mold in the indoor unit Antifreeze function which is used to keep the room temperature at a minimum of 8C during winter Preheating function intelligently to avoid jets of cold air (heating mode) Self-diagnostics function Automatic defrosting of outdoor unit Outdoor unit with connection for the condensate drain washable air filter Washable air filter Air filters easily removed and cleaned Indoor unit with motorised horizontal fin enabling optimal control of air flow directly from the remote control Refrigerant lines with flared ends Easy installation and maintenance

356

Technical data
Indoor unit Outdoor unit Cooling capacity EER Moisture removed Total input power Total absorption Heating capacity COP Total input power Total absorption Rated power input * Rated current * Air ow rate (HW E) HW090E HW090C 2600 3.21 0.8 809 3.59 2800 3.61 775 3.44 1120 4.97 500 440 400 360 40 37 35 32 1800 50 Rotary 15 10 1/4" 3/8" 6.35 (1/4) 9.52 (3/8) HW120E HW120C 3500 3.26 1.4 1075 4.77 3850 3.62 1065 4.70 1500 6.65 630 530 440 360 42 38 36 33 1800 51 Rotary 20 10 1/4" 1/2 6.35 (1/4) 12.7 (1/2) HW180E HW180C 5400 3.42 1.8 1580 7.01 5900 3.61 1630 7.23 2300 10.20 850 780 650 500 45 42 37 33 2800 56 Rotary 25 10 1/4 1/2 6.35 (1/4) 12.7 (1/2) HW240E HW240C 6600 3.21 2.0 2056 9.12 7550 3.41 2215 9.83 2650 11.76 950 800 700 600 47 44 40 37 3200 57 Rotary 25 10 1/4 5/8 6.35 (1/4) 15.9 (5/8)

W l/h W A W W A W A m3/h (Turbo) m3/h (max) m3/h (med) m3/h (min) dB(A) (Turbo) dB(A) (max) dB(A) (med) dB(A) (min) m3/h dB(A)

Sound pressure (HW E)

Air ow rate (HW C) Sound pressure (HW C) Compressor Lines max length m Max level difference (Indoor - outdoor unit) m liquid Refrigerant connections gas mm (inch) liquid Refrigerant lines mm (inch) gas

Electric power supply = 230V ~ 50Hz Sound pressure measures in a semianechoic chamber at 1m from the front * In compliance with the EN 60335 The performance refers to the following conditions (EN-14511): Cooling: - - - - Room air temperature 27C D.B. ; 19C W.B. External air temperature 35C Maximum speed Refrigerant lines length 5m

Heating: - Room air temperature - External air temperature - Maximum speed - Refrigerant lines length 20C 7C D.B. ; 6C W.B. 5m

Dimensional data (mm)

A A B C

HW_E HW090C HW120C HW Height Width Depth Net weight A B C kg 090 E 265 794 182 10 120 E 274 848 189 10 180 E 298 945 208 13 240 E 315 1018 223 15,5 090 C 540 848 320 33.5 120 C 540 848 320 39
B C

HW 180 C 680 913 378 48 240 C 700 955 396 57

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

357

Cod.: SHWUY.01 / 1205

PRELIMINARY

LCI

Split system air conditioner and heat pump Monosplit with capacity from 2.7 to 17kW DC Inverter Technology

R410A
Seasonal Energy Efficiency See Technical data

EX C TE OO RN LIN DO AL T G W E W N MP ITH TO ER -15 ATU C RE

LCI_F

Regulation (EU) N. 206/2012 Delegated Regulation (EU) N. 626/2011

NEW N! DESIG
LCI_C

LCI_D

Wired panel

Controller

Characteristics
The LCI series consist of an external Inverter unit connected to 3 types of internal units External unit: LCI: 8 sizes of different capacity with single phase power LCI_T: 4 sizes of different capacity with three phase power Internal unit: Cassette (False ceiling mounted) (600x600): LCI036CS - 051CS (It is required to connect with accessory LCIGL40S) Cassette (False ceiling mounted) (840x840): LCI071C - 086C - 101C -121C (It is required to connect with accessory LCIGL40) Cassette (False ceiling mounted) (910x910): LCI141CB - 161CB (It is required to connect with accessory LCIGL40B) Floor Ceiling (Wall or ceiling mounted): LCI026F - 036F - 051F - 071F - 086C - 101F 121F - 161F Ducted (Horizontal installation): LCI026D - 036D - 051D - 071D - 086D - 101D - 121D - 141D - 161D Refrigerant R410A Heat pump operation with reversible refrigerant cycle and defrost control The DC Inverter compressors are selected to maximise efficiency, reduce consumption and minimise starting current External unit fitted with one or two fans with DC Inverter motor with continuous speed control Internal unit with 3 speed fan assembly Wired panel and remote controller standard on all internal units Infrared remote controller with liquid crystal display to control all functions Wired panel with liquid crystal display to control all functions Microprocessor control Possibility to set the ambient temperature sensor in the intake of the internal unit or in the wired panel Timer for programming switch on or off Operating modes: Cooling, Heating, Dehumidification, Automatic or Ventilation Only Extremely low noise operation Auto-Restart function: restart as default, can be deactivated Condensate discharge pump in version LCI_C CS - CB Simple installation and maintenance Air filter easily removed and cleaned Flare type refrigerant connections Maximum refrigerant line lengths: - up to 20m for units LCI026, LCI036 and LCI051 - up to 30m for units LCI071, LCI086, LCI101, LCI101T - up to 50m for units LCI121, LCI121T, LCI141, LCI141T and LCI161T Condensation control device standard; allows operation in Cooling with external temperatures down to -15C

358

PRELIMINARY
Technical data
External Unit (E.U.) LCI Internal Unit (I.U.) LCI Cooling capacity SEER Energy efficiency class Power input total Current input Heating capacity SCOP Energy efficiency class Power input total Current input Compressor Fans (E.U.) Airflow rate nominal (I.U.) Sound pressure (I.U.) Sound pressure (E.U.) W A n m3/h dB(A) dB(A) liquid gas W A W W (min) (max) 036 036CS 3400 1600 3600 5,1 A 1030 450 1400 4,6 2,1 6,4 3700 1600 4000 3,8 A 1025 400 1200 4,6 1,8 5,5 1 550 47 54 1/4 3/8 6,35 1/4 9,52 3/8 20 15 051 051CS 5000 1600 5800 5,1 A 1550 550 1750 7,0 2,3 7,5 5500 1400 6500 3,8 A 1524 500 1900 7,3 2,1 8,2 1 1180 47 57 1/4 1/2 6,35 1/4 12,7 1/2 20 15 071 071C 7000 2400 8500 5,1 A 2180 850 2500 9,6 3,7 11,1 8000 2400 9500 3,8 A 2210 800 2780 9,8 3,5 12,3 1 1400 51 59 3/8 5/8 9,52 3/8 15,9 5/8 30 15 086 101 086C 101C 8300 10000 2600 3000 9200 11500 5,1 5,1 A A 2670 3115 850 1040 2980 4200 12,1 14,6 3,7 4,6 13,2 18,5 9200 11000 2400 3500 9900 12800 3,8 3,8 A A 2570 3047 700 900 2720 3520 11,6 13,7 3,1 3,9 12,1 15,5 DC-Inverter 1 1 1660 1660 53 53 59 61 3/8 3/8 5/8 5/8 9,52 9,52 3/8 3/8 15,9 15,9 5/8 5/8 30 30 15 15 121 121C 11000 3500 13000 3426 900 4270 15,2 4,0 18,7 12000 3800 14500 3300 790 4080 14,64 3,5 17,9 1 1660 53 61 3/8 5/8 9,52 3/8 15,9 5/8 50 30 101T 101C 10000 3000 11500 5,1 A 3115 1020 4101 4,8 1,6 6,1 11000 3500 12800 3,8 A 3047 900 3840 4,7 1,4 5,7 1 1660 53 61 3/8 5/8 9,52 3/8 15,9 5/8 30 15 121T 121C 11000 3500 13000 3425 1040 4320 5,4 1,6 6,5 12000 3800 14500 3300 920 4020 4,88 1,4 6,0 1 1660 53 61 3/8 5/8 9,52 3/8 15,9 5/8 50 30

(min) (max) (max) (min) (min) (max)

(min) (max) (min) (max) Type

(Vmax) (max) (max) inch Refrigerant connections inch inch liquid mm Refrigerant lines inch gas mm Maximum refrigerant line lengths m Maximum elevation change m

Power supply internal unit (I.U.): 230V~50Hz Power supply External Unit (E.U.): 230V~50Hz (LCI); 400V 3N~50Hz (LCI_T) Sound pressure measured at 1m distance from front in semi-anechoic chamber * In accordance with Standard EN-60335 Performances in accordance with Standards EN-14511 and EN-14825 Cooling: Ambient air temperature 27C db ; 19C wb External air temperature 35C Maximum speed Refrigerant line length 5m Heating: Ambient air temperature External air temperature Maximum speed Refrigerant line length

- - - -

- - - -

20C 7C db ; 6C wb 5m

Accessories
SUPPLY GRILLE: Supply grilles are motorised. (600x600). Is a required accessory as the unit shipped without. Fitted with infrared receiver and emergency LCI_CS is shipped without. LCIGL40B : Supply and return air grille operation button. LCIGL40: Supply and return air grille (840x840). (910x910). Is a required accessory as the unit LCIGL40S : Supply and return air grilles Is a required accessory as the unit LCI_C is LCI_CB is shipped without. Mod. LCIGL40S LCIGL40 LCIGL40B LCI036CS

LCI051CS

LCI071C

LCI85C

LCI101C

LCI121C

LCI141CB

LCI161CB

Dimensional data (mm)


C C B

Mod. A B C Weight

LCI mm mm mm kg

036 540 848 320 33

051 700 955 396 46

071 790 980 427 65

086 790 980 427 68

101 1101 1107 440 89

121 1101 1107 440 89

141 1365 1085 427 116

101T 1101 1107 440 88


B

121T 1101 1107 440 88

141T 1365 1085 427 116


A

161T 1365 1085 427 118

A B C Weight

LCI mm mm mm kg

036CS* 051CS** 071C** 600 600 840 600 600 840 230 230 240 20 20 27

086C** 840 840 320 32

101C** 840 840 320 32

121C** 141CB*** 161CB*** *:Grille dimensions LCIGL40S mm 670x670x50; 840 910 910 Weight = 5 kg 840 910 910 **:Grille dimensions LCIGL40 mm 950x950x60; Weight = 6,5 kg 320 ***:Grille dimensions LCIGL40B mm 1040x1040x60; 32 -

359

PRELIMINARY
Technical data
External Unit (E.U.) LCI Internal Unit (I.U.) LCI Cooling capacity SEER Energy efficiency class Power input total Current input Heating capacity SCOP Energy efficiency class Power input total Current input Compressor Fans (E.U.) Airflow rate nominal (I.U.) Head nominal (I.U.) Sound pressure (I.U.) Sound pressure (E.U.) Refrigerant connections Refrigerant lines W A n m3/h Pa dB(A) dB(A) liquid gas liquid gas (min) (max) (min) (max) Type (Vmax) (Vmax) (max) (max) inch inch mm inch mm inch m m W A W (min) (max) (min) (max) (min) (max) W (min) (max) 026 026D 2700 1150 3000 A 830 450 1200 3,7 2,1 5,5 2900 1010 3000 A 803 450 1200 3,6 2,1 5,5 1 800 25 37 53 1/4 3/8 6,35 1/4 9,52 3/8 20 15 036 036D 3500 1600 3600 A 1077 480 1400 4,8 2,2 6,4 3800 1600 4000 A 974 450 1200 4,3 2,1 5,5 1 840 25 37 54 1/4 3/8 6,35 1/4 9,52 3/8 20 15 051 051D 5000 1600 5800 A 1550 550 1750 7,0 2,3 7,5 5600 1400 6800 A 1550 500 1900 7,3 2,1 8,2 1 1010 25 42 57 1/4 1/2 6,35 1/4 12,7 1/2 20 15 071 071D 7000 2200 8500 A 2180 850 2500 9,6 3,7 11,1 8000 2400 9500 A 2210 800 2650 9,1 3,5 11,8 1 1600 25 47 59 3/8 5/8 9,52 3/8 15,9 5/8 30 15 086 086D 8300 2400 8700 A 2670 840 3200 11,2 3,7 14,2 9200 2400 9900 A 2570 800 2750 10,7 3,5 12,2 1 1500 37 47 59 3/8 5/8 9,52 3/8 15,9 5/8 30 15 101 101D 10000 3500 11500 A 3115 1380 4180 14,6 6,1 18,4 11000 3800 12800 121 121D 11000 3500 13000 141 141D 14000 5000 14300 4360 1620 5340 20,0 7,1 23,5 16000 5200 18000 4430 1460 5340 21 6,4 23,5 2 2500 50 53 61 3/8 5/8 9,52 3/8 15,9 5/8 50 30 101T 101D 10000 3500 11500 A 3115 1350 4101 4,8 2,1 6,1 11000 3800 12800 A 3047 1220 3680 4,7 1,9 5,5 1 2300 37 53 61 3/8 5/8 9,52 3/8 15,9 5/8 30 15 121T 121D 11000 3500 13000 3425 1340 4520 5,5 2,1 6,8 12000 3800 14500 3320 1230 4101 4,88 1,9 6,1 1 2300 37 53 61 3/8 5/8 9,52 3/8 15,9 5/8 50 30 141T 141D 14000 5000 14300 4360 1600 5360 6,4 2,8 8,0 16000 5200 18000 4430 1440 5320 6,7 2,2 8,0 2 2500 50 53 61 3/8 5/8 9,52 3/8 15,9 5/8 50 30 161T 161D 17000 4000 17500 5290 1680 6380 7,8 2,6 9,5 18000 5000 18800 4980 1400 5460 7,4 2,2 8,2 2 3150 50 54 63 3/8 3/4 9,52 3/8 19 3/4 50 30

5,1

5,1

5,1

5,1

5,1

3,8

3,8

3,8

3,8

3,8

Maximum refrigerant line lengths Maximum elevation change

3426 860 4150 15,2 3,8 18,2 12000 3800 14500 3,8 A 3047 3300 1240 760 3680 3700 14,6 14,64 5,5 3,3 16,2 16,3 DC-Inverter 1 1 2300 2300 37 37 53 53 61 61 3/8 3/8 5/8 5/8 9,52 9,52 3/8 3/8 15,9 15,9 5/8 5/8 30 50 15 30

5,1

5,1

3,8

Power supply Internal Unit (I.U.): 230V~50Hz (LCI_D) Power supply External Unit (E.U.): 230V~50Hz (LCI); 400V 3N~50Hz (LCI_T) Sound pressure measured at 1m distance from front in semi-anechoic chamber * In accordance with Standard EN-60335 Performances in accordance with Standards EN-14511 and EN-14825 - - - - Cooling: Ambient air temperature 27C db ; 19C wb External air temperature 35C Maximum speed Refrigerant line length 5m - - - - Heating: Ambient air temperature External air temperature Maximum speed Refrigerant line length 5m 20C 7C db ; 6C wb

Dimensional data (mm)


Mod. A B C Weight LCI mm mm mm kg 026 540 848 320 33 036 540 848 320 33 051 700 955 396 46 071 790 980 427 65 086 790 980 427 68 101 1101 1107 440 89
B
C B

121 1101 1107 440 89


C

141 1365 1085 427 116


LCI141 LCI141T LCI161T

101T 1101 1107 440 88

121T 1101 1107 440 88

141T 1365 1085 427 116

161T 1365 1085 427 118

A
A C B

LCI026 LCI036 LCI051

LCI071 LCI086 LCI101 LCI121 LCI101T LCI121T

Mod. A B C Weight

LCI mm mm mm kg

026D 250 880 665 26

036D 266 980 721 34

051D 266 980 721 34

071D 268 1270 530 37

086D 268 1270 530 36

101D 290 1226 775 57

121D 290 1226 775 57

141D 330 1226 815 64

161D 389 1463 799 87

360

PRELIMINARY
Technical data
External Unit (E.U.) LCI Internal Unit (I.U.) LCI Cooling capacity SEER Energy efficiency class Power input total Current input Heating capacity SCOP Energy efficiency class Power input total Current input Compressor Fans (E.U.) Airflow rate nominal (I.U.) Sound pressure (I.U.) Sound pressure (E.U.) Refrigerant connections Refrigerant lines W A Type n m3/h dB(A) dB(A) liquid gas liquid gas Maximum refrigerant line lengths Maximum elevation change W A W W (min) (max) 026 026F 3000 1600 3500 5,1 A 857 400 1200 3,8 1,8 5,5 3000 1400 3800 3,8
A

(min) (max) (min) (max) (min) (max)

036 036F 3400 1600 3600 5,1 A 1059 480 1400 4,7 2,2 6,4 3800 1360 4101 3,8
A

051 051F 5000 1600 5800 5,1 A 1550 550 1750 7,0 2,3 7,5 5600 1400 6800 3,8
A

071 071F 7000 2400 8200 5,1 A 2180 850 2500 9,6 3,7 11,1 8000 2400 9000 3,8
A

086 086F 8500 2600 9200 5,1 A 2670 850 2980 12,1 3,7 13,2 9200 2400 9900 3,8
A

101 101F 10500 3500 13000 5,1 A 3270 1080 4040 14,9 4,7 17,7 11200 3500 12500 3,8
A

121 121F 11500 3500 13000 3580 850 4060 15,88 3,7 17,8 12500 3500 14200 -

141 101T 121T 141F 101F 121F 14000 10500 11300 5000 3500 3500 14300 13000 13000 5,1 A 4360 3270 3520 1150 1080 1080 4980 4000 4260 20,0 4,9 5,2 5,1 1,7 1,7 21,8 6,0 6,4 16000 11200 12500 5200 3500 3500 18000 12500 14200 3,8 A -

141T 161T 141F 161F 14000 16000 5000 4000 14300 16500
-

4360 4980 1420 1520 5140 6040 6,21 7,4 2,2 2,3 7,7 9,0 16000 17500 5200 4500 18000 18300 -

(min) (max) (min) (max) (Vmax) (max) (max) inch inch mm inch mm inch m m

750 400 1200 3,3 1,8 5,5 1 650 39 53 1/4 3/8 6,35 1/4 9,52 3/8 20 15

927 450 1200 4,1 2,1 5,5 1 700 39 54 1/4 3/8 6,35 1/4 9,52 3/8 20 15

1550 500 1900 7,3 2,1 8,2 1 900 45 57 1/4 1/2 6,35 1/4 12,7 1/2 20 15

2210 800 2780 9,8 3,5 12,3 1 1200 52 59 3/8 5/8 9,52 3/8 15,9 5/8 30 15

2570 700 2720 11,6 3,1 12,1 1 1600 50 59 3/8 5/8 9,52 3/8 15,9 5/8 30 15

3101 3460 950 720 3840 3820 14,5 15,35 4,2 3,2 16,9 16,8 DC-Inverter 1 1 2000 2000 54 54 61 61 3/8 3/8 5/8 5/8 9,52 9,52 3/8 3/8 15,9 15,9 5/8 5/8 30 50 15 30

4430 980 5080 21 4,3 22,3 2 2300 58 61 3/8 5/8 9,52 3/8 15,9 5/8 50 30

3101 960 3750 4,6 1,5 5,6 1 2000 54 61 3/8 5/8 9,52 3/8 15,9 5/8 30 15

3460 960 3880 5,12 1,5 5,8 1 2000 54 61 3/8 5/8 9,52 3/8 15,9 5/8 50 30

4430 1280 5250 6,5 2,0 7,8 2 2300 58 61 3/8 5/8 9,52 3/8 15,9 5/8 50 30

4840 1290 6330 7,2 2,0 9,5 2 2300 58 63 3/8 3/4 9,52 3/8 19 3/4 50 30

Power supply Internal Unit (I.U.): 230V~50Hz (LCI_F) Power supply External Unit (E.U.): 230V~50Hz (LCI); 400V 3N~50Hz (LCI_T) Sound pressure measured at 1m distance from front in semi-anechoic chamber * In accordance with Standard EN-60335 Performances in accordance with Standards EN-14511 and EN-14825 - - - - Cooling: Ambient air temperature 27C db ; 19C wb External air temperature 35C Maximum speed Refrigerant line length 5m - - - - Heating: Ambient air temperature External air temperature Maximum speed Refrigerant line length 5m 20C 7C db ; 6C wb

Dimensional data (mm)


Mod. A B C Weight LCI mm mm mm kg 026 540 848 320 33 036 540 848 320 33 051 700 955 396 46 071 790 980 427 65 086 790 980 427 68 101 1101 1107 440 89
B
C B

121 1101 1107 440 89


C

141 1365 1085 427 116


LCI141 LCI141T LCI161T

101T 1101 1107 440 88

121T 1101 1107 440 88

141T 1365 1085 427 116

161T 1365 1085 427 118

LCI026 LCI036 LCI051

LCI071 LCI086 LCI101 LCI121 LCI101T LCI121T

Mod. A B C Weight

LCI mm mm mm kg

026F 700 1220 225 40

036F 700 1220 225 40

051F 700 1220 225 42

071F 700 1220 225 43

086F 700 1420 245 51

101F 700 1420 245 53

121F 700 1420 245 55

141F 700 1700 245 64

161F 700 1700 245 65

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

361

Cod.: SLCIUI.01 / 1301

DXE

Heat pump with two air-cooled sections Ducted horizontal installation with power from 20 up to 39,5 kW

DXE 20E

DXE 25E

DXE 30E

DXE 40E

Wired control panel

Remote control

DXE 20CT DXE 25CT

DXE 30CT

DXE 40CT

Features
R410A refrigerant gas Indoor unit (DXE E): Heat Pump Ducted unit for horizontal installation Auto-Restart (function can be deactivated) The units have two air probes: one on the wired Condensate control device for functioning in control panel and one on the internal unit cooling mode with external temperature to return. Can be selected from the wired panel -15C, as per standard Metal cabinet in galvanised sheet steel Double intake centrifugal fans single speed Regenerative air filter Infrared ray remote control with liquid crystal display wired control panel for checking all functions Liquid crystal display wired control panel for checking all functions, infrared receiver and environment temperature probe Microprocessor control Outdoor unit (DXE CT): Metal protection cabinet with anti-corrosion paint Heat exchange coil in copper piping with aluminium louvers Helical fan coupled directly to the electric motor The maximum length of the chiller lines is 50 m and maximum difference in level 30 m

362

Technical data
DXE DXE Cooling capacity Total input power Maximum total current Heating capacity Total input power Maximum total current Power supply (outdoor unit) Power supply (indoor unit) Indoor unit air flow rate Useful static pressures Sound pressure (indoor unit) Sound pressure (outdoor unit) Refrigerant gas load (R410A) * Refrigerant gas top-up Refrigerant lines Refrigerant fittings 20 CT 20 E 20 8,4 15,3 22 7 13,2
400V 3N 50Hz 400V 3N 50Hz

kW kW A kW kW A V-Ph-Hz V-Ph-Hz m3/h Pa dB (A) dB (A) kg g/m (gas) (liquid) (gas) (liquid)

25 CT 25 E 24,5 9,8 22,2 27,5 9 21,2


400V 3N 50Hz 400V 3N 50Hz

30 CT 30 E 30 12,5 27 33 10,5 23
400V 3N 50Hz 400V 3N 50Hz

40 CT 40 E 39,5 13,6 37,8 42 11,8 34


400V 3N 50Hz 400V 3N 50Hz

4000 220 65 65 5,3* 54 3/4(19,05) 3/8(9,52) 3/4(19,05) 3/8(9,52)

4800 110 54 64 6,7* 54 1(25,4) 3/8(9,52) 1(25,4) 3/8(9,52)

5500 120 54 67 9,5 120 9/8(28,6) 1/2(12,7) 9/8(28,6) 1/2(12,7)

7000 150 58 69 12* 170 9/8(28,6) 5/8(15,9)) 9/8(28,6) 5/8(15,9)

The performance refers to the following conditions: Sound pressure measures in a semianechoic chamber, under the unit, at r=1,4m Sound pressure measures in a semianechoic chamber at 1m from the front * =for lines up to 7.5m; over perform top-up Cooling: - Room air temperature 27C D.B. ; 19C W.B. - External air temperature 35C

Heating: - Environmental air temperature 20C - External air temperature 7C D.B. ; 6C W.B.

Dimensional data (mm)


INDOOR UNIT

DXE 20E

DXE 25E

DXE 30E

DXE 40E

OUTDOOR UNIT

DXE 20CT DXE 25CT

DXE 30CT

DXE 40CT

Height Width Depth Weight

A B C kg

20 E 389 1463 799 86

25 E 500 1745 1116 150

40 E 650 1700 1100 215

20 CT 1350 1150 460 158

25 CT 1600 1150 460 185

40CT 1772 1290 800 285

Maximum clearance Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

363

Cod.: SDXEUY.06 / 0211

DXE 30 E 500 1745 1116 170

DXE 30 CT 1772 990 880 218

PRELIMINARY

MKM
R410A

Multisplit system heat pump Inverter MultiSplit System with capacity from 5 to 12kW Wall mounted unit with air ioniser standard

NEW N! DESIG
MKM_WS

x1 x2 x3 x4 x5
Wired panel = MKM_W MKM_WS MKM_C MKM_CS MKM_D MKM_F

Controller Seasonal Energy Efficiency See Technical data MKM_W

MKM_F Regulation (EU) N. 206/2012 Delegated Regulation (EU) N. 626/2011

Controller

MKM_C MKM_CS MKM_D MKM Microprocessor control Possibility to set the ambient temperature sensor in the intake of the internal unit or in the wired panel (MKM_C, MKM_CS, MKM_D, MKM_F) Timer for programming switch on and/or off Operating modes: Cooling, Heating, Dehumidication, Automatic or Ventilation Only Auto-diagnostic function Air filter easily removed and cleaned Efficient defrost control Condensate discharge pump standard in versions MKM_CS, MKM_C and MKM_D Flare type refrigerant connections Multi-line refrigerant connection system, where each internal unit is connected to the external unit through dedicated refrigerant lines Total refrigerant line length: up to 20m for the external units MKM52 and MKM72 up to 70m for the external units MKM73, MKM84 and MKM104 up to 80m for the external unit MKM125

Characteristics
Dualsplit: External units MKM52 and MKM72 connected to 1 or 2 internal units Trisplit: External unit MKM73 connected to 2 or 3 internal units Quadrisplit: External units MKM84 and MKM104 connected to 2, 3 or 4 internal units Pentasplit: External unit MKM125 connected to 3, 4 or 5 internal units Internal unit choices from: Wall (Wall mounted) with remote controller: MKM 20W - 25W - 35W - 50W MKM 20WS - 25WS - 35WS - 50WS Cassette 600x600 (False ceiling mounted) with remote controller and wired panel: MKM35CS - 50CS (it is required to connect with accessory MKMGL40S) Cassette 840x840 (False ceiling mounted) with remote controller and wired panel: MKM35C - 50C - 70C (it is required to connect with accessory MKMGL40) Floor Ceiling (Wall or ceiling mounted) with remote controller and wired panel: MKM25F - 35F - 50F - 70F Ducted (Horizontal installation) with remote controller and wired panel: MKM25D - 35D - 50D - 60D - 70D Nominal head 10Pa (450m3/h) Refrigerant R410A DC Inverter rotary compressor for higher energy savings and for optimised ambient conditions Internal unit with three speed fan External unit multi-speed single fan Rotary compressor with variable speed Horizontally adjustable air discharge louvres (MKM_W, MKM_WS, MKM_C, MKM_CS, MKM_F) Motorised deflector louvres for vertical adjustment of discharge air (MKM_W, MKM_ WS, MKM_C, MKM_CS, MKM_F) Air ioniser standard for wall mounted units (MKM_W, MKM_WS) Extremely low noise operation Infrared remote controller with liquid crystal display to control all functions Wired panel with liquid crystal display and Soft Touch buttons to control all functions (MKM_C, MKM_CS, MKM_D, MKM_F)

364

PRELIMINARY
Accessories
MKMGL40S: (600x600) motorised. Fitted with infrared receiver and MKMGL40: (840x840) emergency operation button. Supply and return air grille. Supply grilles are Is a required accessory as the units MKM_C and MKM_CS are shipped without.

Mod. MKM35CS MKM50CS MKM35C MKM50C MKM70C MKMGL40S MKMGL40

Combination of internal units permitted


internal unit MKM_C - MKM_CS - MKM_D - MKM_F - MKM_W - MKM_WS:
Dualsplit: possible installation of 1 or 2 internal units External unit Dualsplit MKM52 (18k) External unit Dualsplit MKM 72 (24k) Total (k) 7 9 12 14 16 Unit A 20 (7k) 25 (9k) 35 (12k) 20 (7k) 20 (7k) Unit B 20 (7k) 25 (9k) Total (k) 14 16 18 19 21 Unit A 20 (7k) 20 (7k) 25 (9k) 20 (7k) 25 (9k) Unit B 20 (7k) 25 (9k) 25 (9k) 35 (12k) 35 (12k)

18
19 21

25 (9k)
20 (7k) 25 (9k)

25 (9k)
35 (12k) 35 (12k)

24
25 27 30

35 (12k)
20 (7k) 25 (9k) 35 (12k)

35 (12k)
50 (18k) 50 (18k) 50 (18k)

Total (k) 14 16 18 19 21 24 25 27 30 36 21 23

Unit A 20 (7k) 20 (7k) 25 (9k) 20 (7k) 25 (9k) 35 (12k) 20 (7k) 25 (9k) 35 (12k) 50 (18k) 20 (7k) 20 (7k)

Trisplit: it is required to install at least 2 internal units for correct system operation External unit Trisplit MKM73 (24k) Unit B Unit C Total (k) Unit A 20 (7k) 25 20 (7k) 25 (9k) 26 20 (7k) 25 (9k) 27 25 (9k) 35 (12k) 28 20 (7k) 35 (12k) 30 25 (9k) 35 (12k) 31 20 (7k) 50 (18k) 32 20 (7k) 50 (18k) 33 25 (9k) 50 (18k) 34 20 (7k) 50 (18k) 36 25 (9k) 20 (7k) 20 (7k) 36 35 (12k) 20 (7k) 25 (9k) Quadrisplit: it is required to install at least 2 internal units for correct system operation External unit Quadrisplit MKM84 (28k) Unit B Unit C Unit D Total (k) Unit A Unit B 20 (7k) 34 20 (7k) 25 (9k) (25 (9k) 36 25 (9k) 25 (9k) 25 (9k) 36 35 (12k) 35 (12k) 35 (12k) 37 20 (7k) 35 (12k) 35 (12k) 39 25 (9k) 35 (12k) 35 (12k) 42 35 (12k) 35 (12k) 50 (18k) 28 20 (7k) 20 (7k) 50 (18k) 30 20 (7k) 20 (7k) 50 (18k) 32 20 (7k) 20 (7k) 50 (18k) 33 20 (7k) 20 (7k) 20 (7k) 20 (7k) 34 20 (7k) 25 (9k) 20 (7k) 25 (9k) 35 20 (7k) 20 (7k) 25 (9k) 25 (9k) 36 25 (9k) 25 (9k) 20 (7k) 35 (12k) 37 20 (7k) 25 (9k) 25 (9k) 25 (9k) 38 20 (7k) 20 (7k) 25 (9k) 35 (12k) 39 20 (7k) 20 (7k) 25 (9k) 35 (12k) 39 25 (9k) 25 (9k) 35 (12k) 35 (12k) 40 20 (7k) 25 (9k) 20 (7k) 50 (18k) 41 20 (7k) 20 (7k) 35 (12k) 35 (12k) 42 25 (9k) 25 (9k) External unit Quadrisplit MKM104 (36k)

Unit B

Unit C

25 (9k)
20 (7k) 25 (9k) 25 (9k) 25 (9k) 35 (12k) 20 (7k) 35 (12k) 25 (9k) 25 (9k) 35 (12k)

25 (9k)
35 (12k) 25 (9k) 35 (12k) 35 (12k) 35 (12k) 50 (18k) 35 (12k) 50 (18k) 50 (18k) 35 (12k)

Total (k) 14 16 18 19 21 24 25 27 30 36 21 23 25 26 27 28 30 31 32 33

Unit A 20 (7k) 20 (7k) 25 (9k) 20 (7k) 25 (9k) 35 (12k) 20 (7k) 25 (9k) 35 (12k) 50 (18k) 20 (7k) 20 (7k) 20 (7k) 20 (7k) 25 (9k) 20 (7k) 25 (9k) 20 (7k) 20 (7k) 25 (9k)

Unit C 50 (18k) 50 (18k) 35 (12k) 50 (18k) 50 (18k) 50 (18k)

Unit D -

20 (7k)
20 (7k) 25 (9k) 20 (7k) 25 (9k) 25 (9k) 25 (9k) 25 (9k) 35 (12k) 20 (7k) 25 (9k) 35 (12k) 25 (9k) 35 (12k)

20 (7k)
25 (9k) 25 (9k) 35 (12k) 25 (9k) 35 (12k) 25 (9k) 35 (12k) 35 (12k) 50 (18k) 35 (12k) 35 (12k) 50 (18k) 35 (12k)

Total connectable power of the external unit between 50% and 150% of its nominal power (36k) Pentasplit: it is required to install at least 2 internal units for correct system operation External unit Pentasplit MKM125 (42k) Total connectable power of the external unit between 50% and 150% of its nominal power (42k)

365

PRELIMINARY
Technical data
External Unit Cooling capacity Power input SEER Energy efficiency class Heating capacity Power input SCOP Energy efficiency class Power input nominal* Compressor Sound pressure Max number of connected units Power supply W W W W (min) (max) (min) (max) MKM52 5000 2050 6200 1550 500 2550 5,6 A+ 5600 2500 6650 1550 580 2700 3,8 A 2700 57 2 MKM72 7000 2200 10000 2460 650 4550 5,8 A 7700 3600 11000 2560 980 3950 3,8 A 4550 58 2 MKM73 MKM84 7100 8000 2200 2200 10000 10000 2250 2490 650 650 4550 4550 5,1 5,1 A A 8500 9300 3600 2880 11000 11000 2350 2580 980 980 3950 3950 3,8 3,8 A A 4550 4550 Rotary DC Inverter 58 59 3 4
230V ~ 50Hz

(min) (max) (min) (max)

W dB(A) n.

MKM104 10000 2100 11000 3750 700 3900 5,1 A 11000 2600 13000 3800 1300 3900 3,8 A 4880 54 4

MKM125 12100 3500 13600 3590 1300 4900 13000 4500 14000 3540 1300 4400 5300 54 5

Sound pressure measured at 1m distance from front in semi-anechoic chamber * In accordance with Standard EN-60335 Performances in accordance with Standards EN-14511 and EN-14825 - - - - Cooling: Ambient air temperature 27C db ; 19C wb External air temperature 35C Maximum speed Refrigerant line length 5m - - - - Heating: Ambient air temperature External air temperature Maximum speed Refrigerant line length 5m 20C 7C db ; 6C wb

MKM72 with adaptor 1 with adaptor 2 with adaptor 3 with adaptor 4 with adaptor 5 with adaptor 6 with adaptor 7 with adaptor 8 with adaptor 9 with adaptor 10

MKM73

EXTERNAL UNIT MKM84

MKM104

MKM125

9,52 (3/8") 12,7 (1/2") 9,52 (3/8") 12,7 (1/2") 9,52 (3/8") 12,7 (1/2") 6,35 (1/4") 9,52 (3/8") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") 12,7 (1/2") 9,52 (3/8") 12,7 (1/2") 9,52 (3/8") 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") 12,7 (1/2") 9,52 (3/8") 12,7 (1/2") 9,52 (3/8") 6,35 (1/4") 9,52 (3/8") 12,7 (1/2")

12,7 (1/2") 9,52 (3/8") 12,7 (1/2") 9,52 (3/8") 12,7 (1/2") 15,9 (5/8") 12,7 (1/2") 9,52 (3/8") 15,9 (5/8") 9,52 (3/8") 12,7 (1/2") 15,9 (5/8") 12,7 (1/2") 15,9 (5/8") 15,9 (5/8") 9,52 (3/8") 15,9 (5/8") 12,7 (1/2") INTERNAL UNIT - WALL MKM25W MKM35W 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") MKM25WS MKM35WS 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") INTERNAL UNIT - DUCTED MKM25D MKM35D 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") INTERNAL UNIT - CASSETTE 600x600 MKM35CS 6,35 (1/4") 9,52 (3/8") INTERNAL UNIT - CASSETTE 840x840 MKM35C 6,35 (1/4") 9,52 (3/8") INTERNAL UNIT - FLOOR CEILING MKM25F MKM35F 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8")

Model Liquid connection / LINE Gas connection / LINE Model Liquid connection / LINE Gas connection / LINE Model Liquid connection / LINE Gas connection / LINE Model Liquid connection / LINE Gas connection / LINE Model Liquid connection / LINE Gas connection / LINE Model Liquid connection / LINE Gas connection / LINE

MKM20W 6,35 (1/4") 9,52 (3/8") MKM20WS 6,35 (1/4") 9,52 (3/8")

MKM50W 6,35 (1/4") 12,7 (1/2") MKM50WS 6,35 (1/4") 12,7 (1/2") MKM50D 6,35 (1/4") 12,7 (1/2") MKM50CS 6,35 (1/4") 12,7 (1/2") MKM50C 6,35 (1/4") 12,7 (1/2") MKM50F 6,35 (1/4") 12,7 (1/2") MKM70C 9,52 (3/8") 15,9 (5/8") MKM70F 9,52 (3/8") 15,9 (5/8") MKM60D 9,52 (3/8") 15,9 (5/8") MKM70D 9,52 (3/8") 15,9 (5/8")

366

PRELIMINARY
Dimensional data (mm)
A (mm) 265 265 275 298 283 283 305 315 230 230 50 190 190 240 50 200 200 200 200 200 700 700 700 700 700 790 790 790 1103 1103 B (mm) 794 794 845 945 770 770 865 1007 600 600 650 840 840 840 950 782 782 982 1182 1182 1220 1220 1220 1220 955 980 980 980 1087 1087 C (mm) 186 186 180 208 201 201 215 219 600 600 650 840 840 840 950 635 635 635 635 635 225 225 225 225 396 427 427 427 440 440 Weight (kg) 9 9 10 13 8 8 9 12 18 18 5 25 25 30 5 22 24 25 29 29 40 40 40 45 50 63 64 65 102 102

MKM_W

MKM20W MKM25W MKM35W MKM50W MKM20WS MKM25WS MKM35WS MKM50WS MKM35CS* MKM50CS* MKMGL40S MKM35C** MKM50C** MKM70C** MKMGL40 MKM25D MKM35D MKM50D MKM60D MKM70D MKM25F MKM35F MKM50F MKM70F MKM52 MKM72 MKM73 MKM84 MKM104 MKM125

MKM_WS

MKM_C MKMGL40 MKM_CS MKMGL40S

MKM_D

MKM_F

* Requires grille MKMGL40S (650x650mm) ** Requires grille MKMGL40 (950x950mm)

MKM

Aermec reserves the right to make all modifications deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

367

Cod.: SMKMUY.00P / 1301

MDW

Multisplit heat pumps with heat recovery for hot domestic water production Variable refrigerant flow system (VRF) with inverter power input from 10 to 16 kW

Wired panel for MDW HB

MDW HB MDW HBi WT / WTS

Direct expansion indoor units

MDS WN

MDS F

MDS DH

Wired panel

Remote control

MDS C

MDS CS

Features
RNY01 or RNY11: Y-branch. The accessory is composed of two Y-branches, one for the liquid line and one for the discharge line. Mandatory accessory MDW HB: hydronic module for the production of hot water. Internal installation with 5kW or 8kW power Mandatory accessory HBi WT: HBI_WT: 200, 300, 350, 400 litre DHW Storage Tank with main coil and 3kW electric support resistance - Magnesium sacrificial anode - Stainless steel tank and coil - Outdoor covering in painted sheet steel and heat insulation material, thickness 50mm -Indoor installation Mandatory accessory (as an alternative to HBi WTS) HBi_WTS: 200, 300, 350, 400 litre DHW Storage Tank with main coil, integrative coil and 3kW electric support resistance - Magnesium sacrificial anode - Stainless steel tank and coil - Outdoor covering in painted sheet steel and heat insulation material, thickness 50mm - Indoor installation Mandatory accessory (as an alternative to HBi WT) MDSGL40S: air delivery and recovery grille for internal Cassette-type units Mandatory accessory for MDS CS MDSGL40: air delivery and recovery grille for internal Cassette-type units Mandatory accessory for MDS C ECD: remote contact kit. Allows the direct expansion indoor units to be switched on/off via an external contact MDSCC1: centralised command for handling up to 64 communication modules (MDSCM1 accessory), for a maximum of 64 outdoor units MDSCM1: communication module MDSRC: simplified control panel for centralised command. Allows the direct expansion indoor units to be controlled either individually or in groups MDSR: signal repeater. Necessary if the communication cables are more than 1000 metres long

Accessories
RNY01 or RNY11: Y-branch. The accessory is composed of two Y-branches, one for the liquid line and one for the discharge line. Mandatory accessory MDW HB: hydronic module for the production of hot water. Internal installation with 5kW or 8kW power Mandatory accessory HBi WT: HBI_WT: 200, 300, 350, 400 litre DHW Storage Tank with main coil and 3kW electric support resistance - Magnesium sacrificial anode - Stainless steel tank and coil - Outdoor covering in painted sheet steel and heat insulation material, thickness 50mm -Indoor installation Mandatory accessory (as an alternative to
MDW50HB

HBi WTS) HBi_WTS: 200, 300, 350, 400 litre DHW Storage Tank with main coil, integrative coil and 3kW electric support resistance - Magnesium sacrificial anode - Stainless steel tank and coil - Outdoor covering in painted sheet steel and heat insulation material, thickness 50mm - Indoor installation Mandatory accessory (as an alternative to HBi WT) MDSGL40S: air delivery and recovery grille for internal Cassette-type units Mandatory accessory for MDS CS MDSGL40: air delivery and recovery grille for internal Cassette-type units Mandatory accessory for MDS C
Compatibility HBi200WT/WTS

ECD: remote contact kit. Allows the direct expansion indoor units to be switched on/off via an external contact MDSCC1: centralised command for handling up to 64 communication modules (MDSCM1 accessory), for a maximum of 64 outdoor units MDSCM1: communication module MDSRC: simplified control panel for centralised command. Allows the direct expansion indoor units to be controlled either individually or in groups MDSR: signal repeater. Necessary if the communication cables are more than 1000 metres long

MDW100 MDW120 MDW140 MDW160

MDW80HB

HBi300WT/WTS

HBi350WT/WTS

HBi400WT/WTS

368

Operating mode
Cooling only Heating only Hot domestic water

Cooling + hot domestic water

Heating + hot domestic water

Cooling only: - outside air temp. from -5C D.B. to 48C D.B.. Cooling + hot domestic water: - outside air temp. from -5C D.B. to 43C D.B. - accumulation water temp. from 35C to 58C*

Heating only: - outside air temp. from -20C D.B. to 24C D.B Heating + hot domestic water: - outside air temp. from -15C D.B. to 24C D.B. - accumulation water temp. from 35C to 58C* Hot domestic water only: - outside air temp. from -15C D.B. to 43C D.B. - accumulation water temp. from 35C to 58C*C a 58C*

* The maximum temperature that can be set from the wired panel (MDW HB) is 58C. It is, however, possible - via a combination of keys - to modify the upper limit, bringing it from 58C (default) to 65C

Example of connection
Wired panel for MDW HB Supplementary heat sources The supplementary coil is only present in HBi WTS models

MDW HB
R410A R410A

User

Technical water

The main coil is present in all HBi WT / WTS models

Technical water HBi WT HBi WTS RNY* RNY* = RNY01 or RNY11


R410A

Aqueduct

MDW RNY* RNY* RNY* RNY*

RNY*
R410A

MDS WN

MDS C

MDS DH

MDS F

369

Technical data of direct expansion indoor unit


Internal units Cooling capacity Heating capacity Air flow Moisture removed Total power input Sound pressure (min) Sound pressure (max) Cooling connections MDS W W 3 m /h l/h W dB (A) dB (A) liquid gas Type MDS W W 3 m /h l/h W dB (A) liquid gas Type
MDS W W 3 m /h l/h W dB (A) dB (A) liquid gas Type 28C 2800 3200 680 0.8 60 34 37 6.35(1/4) 9.52(3/8) flare 36C 3600 4000 680 0.8 60 34 37 6.35(1/4) 12.7(1/2) flare

22WN 2200 2500 360 1 32 28 31 6.35(1/4) 9.52(3/8) flare

28WN 2800 3200 360 1 32 28 31 6.35(1/4) 9.52(3/8) flare 28CS 2800 3200 600 0.8 12 47 6.35(1/4) 9.52(3/8) flare
45C 4500 5000 680 1.2 65 34 37 6.35(1/4) 12.7(1/2) flare

36WN 3600 4000 500 1.2 48 32 35 6.35(1/4) 12.7(1/2) flare

45WN 4500 5000 500 1.2 48 32 35 6.35(1/4) 12.7(1/2) flare 36CS 3600 4000 600 0.8 12 47 6.35(1/4) 12.7(1/2) flare

50WN 5000 5800 700 2 56 38 42 6.35(1/4) 12.7(1/2) flare

56WN 5600 6300 750 2 58 40 45 9.52(3/8) 15.9(5/8) flare 45CS 4500 5000 600 1.2 12 47 6.35(1/4) 12.7(1/2) flare

Internal units Cooling capacity Heating capacity Air flow Moisture removed Total power input Sound pressure (max) Cooling connections

Internal unit Cooling capacity Heating capacity Air flow Moisture removed Total power input Sound pressure (min) Sound pressure (max) Cooling connections

50C 5000 5500 680 1.2 65 34 37 6.35(1/4) 12.7(1/2) flare

56C 5600 6300 1180 1.9 83 35 39 9.52(3/8) 15.9(5/8) flare

71C 7100 8000 1180 1.9 83 35 39 9.52(3/8) 15.9(5/8) flare

90C 9000 10000 1860 2.7 133 36 40 9.52(3/8) 15.9(5/8) flare

112C 11200 12500 1860 2.7 133 36 40 9.52(3/8) 15.9(5/8) flare

Internal unit Cooling capacity Heating capacity Air flow Total power input ee Sound pressure (max) Cooling connections

MDS W W m3/h W dB (A) liquid gas Type


MDS W W m /h l/h W dB (A) liquid gas Type
3

28F 2800 3200 550 19 37 6.35(1/4) 9.52(3/8) flare


22DH 2200 2500 450 0.7 85 37 6.35(1/4) 9.52(3/8) flare 71DH 7100 8000 1100 2.1 240 45 9.52(3/8) 15.9(5/8) flare

36F 3600 4000 600 19 38 6.35(1/4) 12.7(1/2) flare


28DH 2800 3200 570 0.9 90 39 6.35(1/4) 9.52(3/8) flare 90DH 9000 10000 1700 3 360 48 9.52(3/8) 15.9(5/8) flare

50F 5000 5800 700 75 47 6.35(1/4) 12.7(1/2) flare


36DH 3600 4000 570 0.9 90 39 6.35(1/4) 12.7(1/2) flare 112DH 11200 12500 1700 3 360 48 9.52(3/8) 15.9(5/8) flare

71F 7100 8000 1170 185 50 9.52(3/8) 15.9(5/8) flare


45DH 4500 5000 700 1.3 150 40 6.35(1/4) 12.7(1/2) flare

112F 11200 12500 2200 280 53 9.52(3/8)


15.9(5/8)

flare
56DH 5600 6300 1000 2.1 240 44 9.52(3/8) 15.9(5/8) flare 140DH 14000 14500 2000 3 500 50 9.52(3/8) 15.9(5/8) flare

Internal units Cooling capacity Heating capacity Air flow Moisture removed Total power input

Sound pressure

Cooling connections

Indoor units Cooling capacity Heating capacity Air flow Moisture removed Total power input

MDS W W m /h l/h W dB (A) liquid gas Type


3

Sound pressure

Cooling connections

Indoor unit power supply: 230V~50Hz


Performance values refer to the following conditions: measured at 1m in semi-anechoic chamber Cooling: - room air temperature 27C D.B. 19C W.B. - outside air temperature 35C D.B. measured at 1.4m in semi-anechoic chambe Heating: - room air temperature 20C D.B. - outside air temperature 7C D.B. 6C W.B.

Technical data for hot domestic water accumulation tank


Hot domestic water accumulation tank Capacity Electric resistor power Electric resistor input current Power supply User water connections (In / Out) Main coil water connections (In / Out) Supplementary coil water connections (In / Out) Supplementary coil L xs HBi l kW A m mm 230V ~ 50Hz G1/2 G3/4 G1/2 G3/4 G3/4 10 22 x 0.8 G1/2 G3/4 G1/2 G3/4 G3/4 10 22 x 0.8 G1/2 G3/4 G1/2 G3/4 G3/4 10 22 x 0.8 G1/2 G3/4 G1/2 G3/4 G3/4 10 22 x 0.8 200WT 200 3 13 200WTS 200 3 13 300WT 300 3 13 300WTS 300 3 13 350WT 350 3 13 350WTS 350 3 13 400WT 400 3 13 400WTS 400 3 13

370

Technical data of the external units and hydronic modules


Outdoor units Cooling capacity (nominal) Input power (nominal) Heating capacity (nominal) Input power (nominal) Max input power Total connectable power (min/max) Connectable direct expansion indoor units (min/max) Twin Rotary compressors Fans Sound pressure (max) Refrigerant charge Length of cooling lines (max) Level difference of indoor unit / indoor unit (max) Level difference of outdoor unit / indoor unit (max) Cooling connections (towards indoor units) Cooling connections (towards MDW_HB) Power supply MDW kW kW kW kW kW kW n 2/6 nx Type nx Type dB (A) Kg m m U. Outdoor unit higherm m U. Outdoor unit lower m liquid gas Type liquid gas Type 100 10 4,5 11 3,8 5,7 8/13 2/6 1 x DC Inverter 2 x DC Inverter 56 5 150 10 25 20 9,52 (3/8) 19,05 (3/4) are 12,7 (1/2) 15,9 (5/8) are 120 12 5,0 14 4,2 6,2 8/13 2/7 1 x DC Inverter 2 x DC Inverter 56 5 150 10 25 20 9,52 (3/8) 19,05 (3/4) are 12,7 (1/2) 15,9 (5/8) are 140 14 5,5 15,4 4,9 6,5 8/16 2/7 1 x DC Inverter 2 x DC Inverter 58 7 150 10 25 20 9,52 (3/8) 19,05 (3/4) are 12,7 (1/2) 15,9 (5/8) are 160 16 5,9 17,6 5,3 6,8 8/16 1 x DC Inverter 2 x DC Inverter 60 7 150 10 25 20 9,52 (3/8) 19,05 (3/4) are 12,7 (1/2) 15,9 (5/8) are

230V ~ 50Hz

230V ~ 50Hz

230V ~ 50Hz

230V ~ 50Hz

measured at 1m at the front in semi-anechoic chamber Cooling only: - room air temperature 27C D.B. 19C W.B. - outside air temperature 35C D.B.

Heating only: - room air temperature - outside air temperature

20C D.B. 7C D.B. 6C W.B.

Hot domestic water hydronic module Heating capacity (nominal)* Technical water circulator Total power input Length of cooling lines (max) Level difference of outdoor unit / hydronic module Cooling connections towards outdoor unit Capacity Head (max)

Water connections (In / Out) Length of hydraulic lines Hydronic module / Tank (max) Power supply

MDW kW l/min m W m m liquid gas Type m

50HB 5 16,7 6 80 10 5 12,7 (1/2) 15,9 (5/8) are G3/4 5

80HB 8 16,7 6 80 10 5 12,7 (1/2) 15,9 (5/8) are G3/4 5

230V ~ 50Hz

230V ~ 50Hz

(*) Hot domestic water only: - outside air temperature - initial / final temperature of water in the accumulation tank

20C D.B. 15C W.B. 15C / 55C

Dimensional data (mm)

MDS DH
A mm 770 770 830 830 1020 1020 570 570 570 840 840 840 840 840 840 840 840 695 695 B mm 250 250 285 285 310 310 570 570 570 840 840 840 840 840 840 840 840 840 840

MDS F
C mm 190 190 189 189 228 228 230 230 230 190 190 190 190 240 240 320 320 238 238 Peso kg 8 8 11 11 12 12 20 20 20 25 25 25 25 30 30 38 38 26 26

MDS WN

MDW HB

MDS CS MDS C

MDW

HBi WT HBi WTS

*: Grille dimensions MDSGL40S mm 650x650x50, Weight = 5kg **: Grille dimensions MDSGL40 mm 950x950x60, Weight = 6.5kg Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

371

Code: SMDWUY.00 / 1006

MDS22WN MDS28WN MDS36WN MDS45WN MDS50WN MDS56WN MDS28CS* MDS36CS* MDS45CS* MDS28C** MDS36C** MDS45C** MDS50C** MDS56C** MDS71C** MDS90C** MDS112C** MDS28F MDS36F

MDS50F MDS71F MDS112F MDS22DH MDS28DH MDS36DH MDS45DH MDS56DH MDS71DH MDS90DH MDS112DH MDS140DH MDW100 MDW120 MDW140 MDW160 MDW50HB MDW80HB HBi200WT / WTS HBi300WT / WTS HBi350WT / WTS HBi400WT / WTS

A mm 695 600 695 880 880 880 980 1155 1155 1425 1425 1425 1250 1250 1250 1250 250 250 1595 1620 1895 2125

B mm 840 1300 1590 665 665 665 721 756 756 756 756 756 950 950 950 950 650 650 540 620 620 620

C mm 238 188 238 250 250 250 266 300 300 300 300 300 340 340 340 340 300 300 / / / /

Peso kg 26 32 42 29 31 31 36 51 51 64 64 66 105 105 115 115 25 25 68/71 82/87 96/100 106/110

MVF-MDS
R410A
MDS WN

Multisplit heat pumps with Variable Refrigerant Flow System (VRF) with capacities from 10 up to 60 kW

MDS C

MDS DH MDS F Wire control panel Infrared remote control

Silencer for MDS WN and MDS F

MVF100 - MVF120 MVF140 - MVF140T MVF160T - MDS120

MDS260T MDS300T

MDS450T

MDS560T MDS600T

Characteristics
Available in 6 versions of MDS condensing units and 5 versions of MDS condensing units MVF. Combination with different types of indoor units: wall (MDS WN), cassette (MDS C / CS), foor-ceiling (MDS F) and duct type (MDS DH) From 2 to 32 indoor units can be connected R410A refrigerant gas Total power connectable to the outdoor unit between 50% and 135% of its rated power Wire control panel standard on all indoor units Infrared remote control standard on all indoor units DC Inverter (MVF) and Digital scroll compressors (MDS) have been chosen to maximise efficiency, reduce consumption, and minimise peak absorption to efficiently check the oil return to the compressor, to optimize the ambient temperature and humidity MVF outdoor unit is equipped by two fans with Inverter AC motor variable speed. Microprocessor control In the MDS systems, the refrigerator connections are created using braze welded Y-shunts (supplied as a mandatory accessory), ensuring flexibility in the installation and full respect for the safety regulations, as well as lower environmental impact due to the absence of leaks Extremely quiet operation Air filter easy to remove and regeneratable Maximum length of refrigerator lines up to 150m for the MVF100, MVF120, MVF140, MVF140T, MVF160T units Maximum length of refrigerator lines up to 300m for the MDS120 units; up to 500m for the MDS260T, MDS 300T, MDS450T, MDS560T and MDS600T units Auto-Restart enabled by default if necessary disabled Condensation control device as standard supply; enables operation even with low outdoor temperatures

Accessories
RNY11: Y-shunt for total installed power downstream less than or equal to 20 kW; the accessory is composed of two Y-shunts, one for the liquid line and one for the gas line. RNY12: Y-shunt for total installed power downstream greater than 20 kW but less than or equal to 30 kW; the accessory is composed of two Y-shunts, one for the liquid line and one for the gas line. RNY21: Y-shunt for total installed power downstream greater than 30 kW; the accessory is composed of two Y-shunts, one for the liquid line and one for the gas line. MDSGL40S: Air delivery/return grille. This is a MDSR: Signal repeater; necessary if the commandatory accessory, as the MDS CS units are munication cables are more than 1000 metres delivered without them. long. MDSGL40: Air delivery/return grille. This is a ECD: Kit remote contact. Allows you to manamandatory accessory, as the MDS C units are ge the on / off indoor units with direct expandelivered without them. sion via external contact MDSCC1: Centralised control by means of which MDSRC: Simplified control panel for centraliup to 64 communication modules (MDSCM1 zed control. Allows you to control the direct accessory) can be handled, for a maximum of 64 expansion indoor units individually or in outdoor units and 1024 indoor units. groups MDSCM1: Communication module. Up to 16 indoor units and the related outdoor unit can be connected to each module.

372

Connection examples

RNY

RNY

RNY

MDS/MVF

RNY MDS WN

MDS C

MDS WN

MDS F

RNY

RNY

RNY

RNY

MDS C MDS WN MDS WN MDS DH

Technical data
Outdoor units Cooling capacity (nominal) Total absorbed power (nominal) EER Heating capacity (nominal) Absorbed power (nominal) COP Maximum absorbed power (1) Total input power (min/max) Max. number of units connectable Compressors kW kW W/W kW kW W/W kW kW n. DC Inverter Digital Scroll Scroll On/Off m/h m MVF 100 10 2,86 3,50 11 2,60 4,23 5,9 5/13,5 6 1 --6000 150 10 30 25 2 58 9,52 (3/8) 15,9 (5/8) are MVF 120 12 3,50 3,43 14 3,40 4,12 6 6/16,2 7 1 --6000 150 10 30 25 2 58 9,52 (3/8) 15,9 (5/8) are MVF 140 14 4,36 3,21 15,4 4,05 3,80 6,1 7/18,9 8 1 --6000 150 10 30 25 2 58 9,52 (3/8) 15,9 (5/8) are MVF 140T 14 4,50 3,11 15,4 4,30 3,58 6,1 7/18,9 8 1 --6000 150 10 30 25 MVF 160T 16 5,10 3,14 17,6 4,80 3,67 6,6 8/21,6 9 1 --6000 150 10 30 25 MDS 120 12 3,9 14 3,8 6 6/16,2 7 -1 -5820 300 10 30 25 MDS 260T 26 8,5 28,5 8,0 15 13/35,1 16 -1 1 12000 500 15 50 40 MDS 300T 30 9,0 3,33 33,5 8,8 3,8 15 15/40,5 16 -1 1 12000 500 15 50 40

MDS F

MDS 450T 45 14,5 48 13,7 20,3 22,5/60,8 16 -1 2 12000 500 15 50 40

MDS 560T 56 18,5 60 18 28 28/75,6 32 -1 3 20000 500 15 50 40

MDS 600T 60 19,2 63 18,2 30 30/81 32 -1 3 24000 500 15 50 40

Air ow Lung. max. linee Max. height difference. m (indoor-indoor unit) Max. height difference m (outdoor-outdoor unit)*2 Max. height difference m (indoor-outdoor unit)**3 Fans n. Sound pressure dB (A) liquid Refrigerator connections gas Type Feeding

2 2 2 1 1 1 2 2 58 60 58 58 58 60 60 60 9,52 9,52 9,52 9,52 9,52 12,7 15,9 15,9 (3/8) (3/8) (3/8) (3/8) (3/8) (1/2) (5/8) (5/8) 15,9 19 15,9 22,2 22,2 28,6 28,6 28,6 (5/8) (3/4) (5/8) (7/8) (7/8) (1 1/8) (1 1/8) (1 1/8) are are are brazing brazing brazing brazing brazing 400V~3N 400V~3N 3N~400V 3N~400V 3N~400V 3N~400V 3N~400V 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz

measured at 1 m frontal in semianechoic chamber. Cooling: - room air temperature 27 C D.B., 19 C W.B. - outdoor air temperature 35 C D.B.

(1) = according to the Standard EN-60335 (2) = outdoor unit installed in a higher position than the indoor unit (3) = outdoor unit installed in a lower position than the indoor unit misurata a 1 m frontale in camera semianecoica Heating: - room air temperature 20 C D.B. - outdoor air temperature 7 C D.B., 6 C W.B.

373

Technical data
Indoor units Cooling capacity Heating capacity Air ow Moisture removed Total absorbed power Sound pressure (min.) Sound pressure (max.) Refrigerator connections Feeding Indoor units Cooling capacity Heating capacity Air ow Moisture removed Total absorbed power Sound pressure (min.) Sound pressure (max.) Refrigerator connections Feeding Indoor units Cooling capacity Heating capacity Air ow Moisture removed Total absorbed power Sound pressure (max.) Refrigerator connections Feeding Indoor units Cooling capacity Heating capacity Air ow Total absorbed power Sound pressure (max.) Refrigerator connections Feeding Indoor units Cooling capacity Heating capacity Air ow Moisture removed Total absorbed power Sound pressure Feeding Indoor units Cooling capacity Heating capacity Air ow Moisture removed Total absorbed power Sound pressure Feeding MDS W W m3/h l/h W dB (A) dB (A) liquid gas Tipy 22WN 2200 2500 360 1 32 28 31 6,35(1/4) 9,52(3/8) are 230V ~ 50Hz 28WN 2800 3200 360 1 32 28 31 6,35(1/4) 9,52(3/8) are 230V ~ 50Hz 36WN 3600 4000 500 1,2 48 32 35 6,35(1/4) 12,7(1/2) are 230V ~ 50Hz 45WN 4500 5000 500 1,2 48 32 35 6,35(1/4) 12,7(1/2) are 230V ~ 50Hz 50WN 56WN 5000 5600 5800 6300 700 750 2 2 56 58 38 40 42 45 6,35(1/4) 9,52(3/8) 12,7(1/2) 15,9(5/8) are are 230V ~ 50Hz 230V ~ 50Hz

MDS W W m3/h l/h W dB (A) dB (A) liquid gas Type

28C 36C 45C 50C 56C 71C 90C 112C 2800 3600 4500 5000 5600 7100 9000 11200 3200 4000 5000 5500 6300 8000 10000 12500 680 680 680 680 1180 1180 1860 1860 0,8 0,8 1,2 1,2 1,9 1,9 2,7 2,7 60 60 65 65 83 83 133 133 34 34 34 34 35 35 36 36 37 37 37 37 39 39 40 40 6,35(1/4) 6,35(1/4) 6,35(1/4) 6,35(1/4) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8) 9,52(3/8) 12,7(1/2) 12,7(1/2) 12,7(1/2) 15,9(5/8) 15,9(5/8) 15,9(5/8) 15,9(5/8) are are are are are are are are 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 230V ~ 50Hz 28CS 2800 3200 600 0,8 12 47 6,35(1/4) 9,52(3/8) are 230V ~ 50Hz 28F 2800 3200 550 19 37 6,35(1/4) 9,52(3/8) are 230V ~ 50Hz 22DH 2200 2500 450 0,7 85 37 6,35(1/4) 9,52(3/8) are 230V ~ 50Hz 71DH 7100 8000 1100 2,1 240 45 9,52(3/8) 15,9(5/8) are 230V ~ 50Hz 36F 3600 4000 600 19 38 6,35(1/4) 12,7(1/2) are 230V ~ 50Hz 28DH 2800 3200 570 0,9 90 39 6,35(1/4) 9,52(3/8) are 230V ~ 50Hz 36CS 3600 4000 600 0,8 12 47 6,35(1/4) 12,7(1/2) are 230V ~ 50Hz 50F 5000 5800 700 75 47 6,35(1/4) 12,7(1/2) are 230V ~ 50Hz 36DH 3600 4000 570 0,9 90 39 6,35(1/4) 12,7(1/2) are 230V ~ 50Hz 71F 7100 8000 1170 185 50 9,52(3/8) 15,9(5/8) are 230V ~ 50Hz 45DH 4500 5000 700 1,3 150 40 6,35(1/4) 12,7(1/2) are 230V ~ 50Hz 45CS 4500 5000 600 1,2 12 47 6,35(1/4) 12,7(1/2) are 230V ~ 50Hz 112F 11200 12500 2200 280 53 9,52(3/8) 15,9(5/8) are 230V ~ 50Hz 56DH 5600 6300 1000 2,1 240 44 9,52(3/8) 15,9(5/8) are 230V ~ 50Hz 140DH 14000 14500 2000 3 500 50 9,52(3/8) 15,9(5/8) are 230V ~ 50Hz

MDS W W m3/h l/h W dB (A) liquid gas Type

MDS W W m3/h W dB (A) liquid gas Type

Refrigerator connections

MDS W W m3/h l/h W dB (A) liquid gas Type

Refrigerator connections

MDS W W m3/h l/h W dB (A) liquid gas Type

90DH 9000 10000 1700 3 360 48 9,52(3/8) 15,9(5/8) are 230V ~ 50Hz

112DH 11200 12500 1700 3 360 48 9,52(3/8) 15,9(5/8) are 230V ~ 50Hz

The performance data refer to the following conditions: measured at 1 m in semianechoic chamber measured at 1.4 m in semianechoic chamber Cooling: - room air temperature 27 C D.B., 19 C W.B. - outdoor air temperature 35 C D.B.

Heating: - room air temperature 20 C D.B. - outdoor air temperature 7 C D.B., 6 C W.B

374

Dimensional data (mm)


A (mm) 250 250 285 285 310 310 840 840 840 840 840 840 840 840 570 570 570 695 695 695 600 695 880 880 880 980 1155 1155 1425 1425 1425 1250 1250 1250 1250 1250 1250 1772 1772 1772 1760 1760 B (mm) 770 770 830 830 1020 1020 840 840 840 840 840 840 840 840 570 570 570 840 840 840 1300 1590 665 665 665 721 756 756 756 756 756 950 950 950 950 950 1100 990 990 1290 1980 1980 C (mm) 190 190 189 189 228 228 190 190 190 190 240 240 320 320 230 230 230 238 238 238 188 238 250 250 250 266 300 300 300 300 300 340 340 340 340 340 340 880 880 880 920 920 weight (kg) 8 8 11 11 12 12 25 25 25 25 30 30 38 38 20 20 20 26 26 26 32 42 29 31 31 36 51 51 64 64 66 111 111 111 115 115 140 280 300 450 600 600

MDS WN

MDS F

MDS CS / C

MDS DH

MDS22WN MDS28WN MDS36WN MDS45WN MDS50WN MDS56WN MDS28C* MDS36C* MDS45C* MDS50C* MDS56C* MDS71C* MDS90C* MDS112C* MDS28CS** MDS36CS** MDS45CS** MDS28F MDS36F MDS50F MDS71F MDS112F MDS22DH MDS28DH MDS36DH MDS45DH MDS56DH MDS71DH MDS90DH MDS112DH MDS140DH MVF100 MVF120 MVF140 MVF140T MVF160T MDS120 MDS260T MDS300T MDS450T MDS560T MDS600T

MVF100 - MVF120 MVF140 - MVF140T MVF160T MDS120

*: MDSGL40 grille 950x950x60 mm; Weight = 6,5 kg; **: MDSGL40S grille650x650x50 mm; Weight = 5 kg; MDS260T - MDS300T

MDS450T
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

MDS560T - MDS600T
Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

375

Cod.: SMDSUY.05 / 1302

EWIH
R410A

Split system heat pumps Wall installation with capacities from 2,6 up to 7,0 kW with Inverter and Plasmacluster filter

EWI 091 H EWI 121 H

Seasonal Energy Efficiency See Technical data

Plasmacluster

EWI 182 H EWI 242 H

CWI H
Regulation (EU) N. 206/2012 Delegated Regulation (EU) N. 626/2011 PLASMACLUSTER ionising filter. Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them. Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air. The result is in the air: you can finally breath clean, odour-free ionised air. EWIH is fitted with a new generation filter: PLASMACLUSTER produces even more ions than the previous version. The result is faster air purification in the climate controlled environment. The COANDA effect EWIH is fitted with new vertical deflectors which, in addition to the standard positions used in cooling and heating mode, can also direct the air flow towards the ceiling (cooling function) or towards the floor (heating function). The result is better air distribution around the room without irritating draughts

Features
With R410A refrigerant Available in 4 different power versions Inverter technology for large power savings and optimized room comfort conditions Room reaches required temperature after switching on in 2/3 the time of an equivalent appliance without an inverter Excellent ratio between heating capacity and cooling capacity, thanks to the inverter-controlled compressor Three-speed cross flow fan Variable speed rotary compressor Air outlet deflectors with horizontal adjustment facility Motorized louver controllable from remote handset for vertical adjustment of outlet air flow direction Very quiet operation Infrared remote handset with LCD display for full control of all functions of the appliance Microprocessor control Local control facility Timer for programming On/Off times Programs for cooling only, heating only, dehumidification and automatic operation (heating/cooling) Self-diagnostics function Easily removable, washable air filter with anti-mould treatment Defrost control

Condensation control device for operation in cooling mode with an external temperature up to -10C

Refrigerant lines with flared ends Refrigerant lines up to 15m for (091H 121H), up to 20m for (EWI 182H) and up to 30m for(EWI 242H)

376

Technical data
EWI 091 H CWI 091 H 2640 900 - 3000 A++ 6,3 780 200 - 960 3,7 0,7 516 438 330 3100 900 - 4800 A+ 4,3 730 160 - 1400 3,5 39 28 45 1398 1/4 3/8 EWI 121 H EWI 182 H CWI 121 H CWI 182 H 3500 5000 1400 - 5700 900 - 3800 A A++ 6,7 5,4 1470 1090 260 - 1890 210 - 1300 6,6 5,0 1,6 1,2 864 588 726 510 570 414 5700 4000 1100 - 8000 1000 - 6000 A A 3,8 3,9 1510 1030 240 - 2380 180 - 1900 6,8 4,8 230V ~ 50Hz 43 40 39 28 49 48 2658 1602 1/4 1/4 3/8 1/2 EWI 242 H CWI 242 H 7000 1500 - 8000 A+
5,9 2160 260 - 2990 9,6 2,6 1104 864 642 7500 1100 - 9500 A+ 4,0 2015 240 - 2830 8,9 47 42 53 2736 1/4 5/8

Cooling capacity Energy Efficiency SEER Input power


Input current

nominal min. - max.

W W W/W W W A l/h m3/h m3/h m3/h W W W/W W W A max. dB (A) min. dB (A) dB (A) m3/h

Moisture removed Indoor unit air flow rate

Heating capacity

nominal min. - max. nominal max. speed max. med. min. nominale min. - max.

Energy Efficiency SCOP Input power Input current Power supply

nominale min. - max. nominale Indoor unit outdoor unit liquid gas

Sound pressure
Outdoor unit air flow rate Refrigerant connections

Performance values refer to the following conditions: measured at 1.3m in an anechoic chamber. Cooling: - room air temperature 27C D.B., 19C W.B.; - ambient air temperature 35C; maximum speed.

Heating: - room air temperature 20C; - ambient air temp. 7C D.B., 6C W.B.; max. speed

Dimensions (mm)

OUTDOOR UNIT

INDOOR UNIT

EWI 091 H EWI 121 H CWI 091 H CWI 121 H CWI 182 H CWI 242 H

INDOOR UNIT

EWI 182 H EWI 242 H


A B C kg EWI 091 H 278 790 198 10 EWI 121 H 278 790 198 10 EWI 182 H 325 1040 222 12 EWI 242 H 325 1040 222 13 CWI 091 H 540 730 250 36 CWI 121 H 540 730 250 36 CWI 182 H 710 850 330 49 CWI 242 H 710 850 330 53

Height Width Depth Weight

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com

377

Cod.: SEWIHUY.10 / 1302

EFI

Split system heat pumps Universal installation with capacities from 2,6 up to 7 kW with Inverter and Plasmacluster filter

R410A

Seasonal Energy Efficiency See Technical data

Plasmacluster

Regulation (EU) N. 206/2012 Delegated Regulation (EU) N. 626/2011 PLASMACLUSTER ionising filter. Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them. Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air. The result is in the air: you can finally breath clean, odour-free ionised air.

Features
Available in 4 different power versions Inverter technology for large power savings and optimized room comfort conditions Room reaches required temperature after switching on in 2/3 the time of an equivalent appliance without an inverter Excellent ratio between heating capacity and cooling capacity, thanks to the inverter-controlled compressor Can be installed in vertical or horizontal positions Variable speed rotary compressor Condensation control device for operation in cooling mode with an external temperature up Programs for cooling only, heating only, dehuto -10C, standard for 091H, 121H, 181H and midification, automatic operation (heating/coo241H ling) Air outlet deflectors with horizontal adjustment Self-diagnostics function facility Refrigeration lines up to 15m for EFI 091 - 121, Motorized louver controllable from remote up to 30m for EFI 181 - 241 handset for vertical adjustment of outlet air flow direction Very quiet operation Infrared remote handset with LCD display for full control of all appliance functions Microprocessor control Timer for programming On/Off times

378

Technical data
EFI 091 H CWI 091 H 2640 900 - 3400 A++ 6,3 780 230 - 960 3,6 1,2 - 4,4 3100 900 - 4500 A+ 4,3 730 250 - 1120 3,5 1,3 - 5,4 666 540 396 1398 39 34 28 45 1/4 3/8 EFI 121 H CWI 121 H 3500 900 - 4000 A 5,4 1090 230 - 1300 5,0 1,2 - 6,0 4000 900 - 5800 A 3,9 1030 290 - 1750 4,7 1,3 - 7,0 720 570 420 1460 41 35 29 48 1/4 3/8 EFI 181 H CFI 181 H 5000 1700 - 6100 A+ 5,6 1560 370 - 2650 7,2 1,7 - 12,3 6200 1700 - 7500 A 3,9 1700 370 - 2200 7,8 1,7 - 10,0 990 798 660 3240 43 38 34 54 1/4 1/2 EFI 241 H CFI 241 H 7000 2400 - 8000 A 5,2 2180 630 - 3120 10,0 2,9 - 14,3 8000 2800 - 9000 A 3,7 2210 730 - 2800 10,1 3,4 - 12,9 1140 930 690 3180 46 41 34 55 3/8 5/8

Cooling capacity Energy Efficiency SEER Total input power Total input current Heating capacity Energy Efficiency SCOP Total input power Total input current

W (nominale) W (min. - max.)

W (nominale) W (min. - max.) A (nominale) A (min. - max.) W (nominale) W (min. - max.)

Air flow rate (EFI) Air flow rate (CFI - CWI) Sound pressure (EFI) Sound pressure (CFI - CWI) Refrigerant connections

W (nominale) W (min. - max.) A (nominale) A (min. - max.) m3/h (max.) m3/h (med.) m3/h (min.) m3/h dB (A) (max.) dB (A) (med.) dB (A) (min.) dB (A) liquido gas

Power supply = 230V ~ 50Hz Performance values refer to the following conditions: = measured at 1.3 m in an anechoic chamber

Cooling: - room air temperature 27C D.B. ; 19C W.B. - ambient air temperature 35C ; maximum speed

Heating: - room air temperature 20C - ambient air temp. 7C D.B. ; 6C W.B. ; maximum speed

Dimensions (mm)

CWI091H CWI121H EFI-H EFI 091 H Height Width Depth Weight A B C kg 680 1025 212 31 121 H 680 1025 212 31 181 H 680 1300 212 34 241 H 680 1300 212 36 CWI 091 H 540 730 250 33 CWI 121 H 540 730 250 37 CFI 181 H 800 890 320 57 CFI 241 H 800 890 320 65

CFI181H CFI241H Cod.: SEFIUY.07 / 1301

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

379

EXCI
R410A

Split system air conditioners and heat pumps Ductable installation with capacitie from 2.6 up to 3.5 kW with Inverter

Seasonal Energy Efficiency See Technical data

Plasmacluster

Regulation (EU) N. 206/2012 Delegated Regulation (EU) N. 626/2011

Features
With R410A refrigerant Available in 2 versions with different power Inverter technology for large power savings and optimized room comfort conditions Room reaches required temperature after switching on in 2/3 the time of an equivalent appliance without an inverter Excellent ratio between heating capacity and cooling capacity, thanks to the inverter-controlled compressor Variable speed rotary compressor Indoor unit with three-speed centrifugal fan with possibility to change the electrical connections in order to obtain a greater available static pressure Very quiet operation Microprocessor control Timer for programming On/Off times Programs for cooling only, heating only, dehumidification and automatic operation (heating/cooling) Air filter Refrigerant lines with flared connections Refrigeration lines up to 15m Wide range of accessories Condensation control device for operation in cooling mode with an external temperature up to -10C, standard for CWI 091H and 121H

380

Technical data
EXC 090 I CWI 091 H 2640 900 - 3000 A++ 6,3 820 230 - 960 3,8 4,4 0,7 3100 900 - 4200 A+ 4,3 740 250 - 1160 3,5 5,4 35 30 26 45 460 370 290 1398 1/4 3/8 EXC 120 I CWI 121 H 3500 900 - 3800 A 5,4 1090 230 - 1300 5,0 6,0 1,2 4000 1000 - 5400 A 3,9 1030 250 - 1620 4,7 7,3 36,5 32 26,5 48 520 410 320 1602 1/4 3/8

Cooling capacity Energy Efficiency SEER Total input power Total input current Moisture removed Heating capacity Energy Efficiency SCOP Total input power Total input current

nominal min. - max. W/W nominal min. - max. nominal max maximum speed nominale min. - max. W/W nominal min. - max. nominal max Indoor unit Outdoor unit max. med. min. liquid gas

W W

W W A A l/h W W

Sound pressure

Indoor unit air flow rate Outdoor unit air flow rate Refrigerant connections Power supply = 230V ~ 50Hz

W W A A max. dB (A) med. dB (A) min. dB (A) dB (A) m3/h m3/h m3/h m3/h

Performance values refer to the following conditions: measured at 1.3m in an anechoic chamber. Cooling: - room air temperature 27C D.B. ; 19C W.B. - ambient air temperature 35C - maximum speed

Heating: - room air temperature 20C - ambient air temp. 7C D.B. ; 6C W.B ; - maximum speed

381

Accessories
AMP: Kit for ceiling mounting. BC: Auxiliary condensate drip tray. DSC : Condensate drainage device for use when natural run-off is not possible. GA: Intake louver with fixed slats. GAF: Intake louver with fixed slats and filter. GM: Delivery louver with adjustable slats. MA: Vertical cabinet. MU: Universal cabinet. PA: Intake plenum in galvanized steel, with EXC CWI AMP BC DSC GA 4* 5** 8 4 22 32 42 22 32 42 22 32 42 22 32 42 22 32 42 22 32 42 22 23 32 33 42 43 22 32 42 22 32 42 22 32 42 22 32 42 22 32 42 20X 30X 40X 2I *** 5 7 plastic outlet connections for circular section SE: Manually operated fresh air intake louver. ducting. TL2I : Infrared remote handset with LCD PC: Rear cover panel. display for full control of all appliance fun PM: Delivery plenum in galvanized steel with ctions. Kit including receiver for wall installaexternal insulation, with plastic outlet contion. (Obligatory accessory). nections for circular section ducting. ZX : Feet for floor standing installation of RD: Delivery straight duct connection. models with MA accessory; or built-in instal RDA: Intake straight duct connection. lation. RP: Delivery 90 duct connection. RPA: Intake 90 duct connection. Compatibility of accessories 090 I 091 H
** = in combination with accessory MU

070 I 071 H

120 I 121 H

GAF

GM

MA

MU

PA

PC

PM

RD

RDA

RP

RPA

SE TL ZX


*** = Obligatory accessor

* = in combination with accessory MA

382

Dimensions (mm)
EXC 090 I - 120 I EXC A B C D E F G H L M N P Weight (Kg) 090 I 457 823 216 671 453 41 101 74 260 144 49 753 23 120 I 457 1043 216 891 453 41 101 74 260 144 49 973 26

CWI Height Width Depth Weight

A B C kg

091 H 540 730 250 36

121 H 540 730 250 37

CWI H

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

383

Cod.: SEXCIUY.05 / 1301

EFSI
R410A

Split system heat pumps Floor installation with capacities from 2.5 up to 5 kW with Inverter and Plasmacluster filter HE

AT IN G OU O TS ID PERA TIO DO E TE N WN MP WI TH TO ERAT U -15 RE C

Seasonal Energy Efficiency See Technical data

Plasmacluster

Regulation (EU) N. 206/2012 Delegated Regulation (EU) N. 626/2011

PLASMACLUSTER ionising filter Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them. Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air. The result is in the air: you can finally breath clean, odour-free ionised air.

Features
With R410A refrigerant gas Available in 3 versions of different capacities Vertical, free-standing installation Elegant design and compact size Plasmacluster air purifier Inverter technology for large power savings and optimised room comfort conditions Following ignition, the required temperature is reached in 2/3 of the time taken by an air conditioning system without Inverter High heating capacity - cooling capacity ratio, thanks to the Inverter Variable speed rotary compressor Double delivery, with air outlet fins in both the lower and upper parts, for better air distribution and to minimise temperature differences at different heights Air distribution differentiated between cooling and heating mode, to obtain the maximum comfort Microprocessor control Infrared remote control with liquid crystal screen for controlling all the functions Timer for programming on/off times Operation modes: Cooling, Heating, Dehumidification and Automatic Auto-restart Self-diagnostics function Particularly quiet operation Regenerable air filter Refrigerant lines with flared ends Ease of installation and maintenance Condensation control device for cooling mode with outside temperatures down to -10C Heating mode with outside temperatures down to -15C

384

Technical data
EFSI 090 H W (nominal) W (min. - max.) CFSI 090 H 2500 900 - 3000 A 4,07 615 200 - 890 2,9 1,0 - 4,0 0,4 276 444 594 45 3400 900 - 5000 A 4,36 780 200 - 1400 3,6 1,0 - 6,3 342 480 612 46 22 29 37 20 7 1/4 3/8 EFSI 120 H CFSI 120 H 3500 900 - 4000 A 3,26 1075 230 - 1320 5,0 1,1 - 6,0 0,95 300 498 630 46 4500 900 - 6000 A 3,66 1230 230 - 1730 5,7 1,1 - 7,7 366 510 660 47 23 31 38 20 7 1/4 3/8 EFSI 180 H CWI 181 H 5000 900 - 5700 B 3,01 1660 260 - 2190 7,4 1,3 - 9,7 1,6 480 702 852 49 5700 900 - 7700 A 3,61 1580 260 - 2400 7,0 1,3 - 10,6 582 738 888 52 33 39 44 30 10 1/4 1/2

Cooling capacity Energy Efficiency Cooling Mode SEER Total input power Total input current Humidity removed Air flow rate (EFSI) Sound pressure (CFSI - CWI) Heating capacity Energy Effinciency Heating Mode SCOP Total input power Total input current Air flow rate (EFSI) Sound Pressure (CFSI - CWI) Sound Pressure (EFSI) Line max lenghts Max level difference Refrigerant connections

W (nominal) W (min. - max.) A (nominal) A (min. - max.) l/h m3/h (min) m3/h (med) m3/h (max) dB (A) W (nominal) W (min. - max.)

W (nominal) W (min. - max.) A (nominal) W (min. - max.) m3/h (max) m3/h (max) m3/h (max) dB (A) dB (A) (min) dB (A) (med) dB (A) (max) m (max) m (max) liquid max

Electric power supply = 230V ~ 50Hz Performance values refer to the following conditions: = measured in anechoic chamber at 1.3m from front, direction factor 4 = measured in anechoic chamber at 1m from front, direction factor 2 Cooling: - Room air temperature 27C B.S. ; 19C B.U. - Ambient air temperature 35C - Maximum Speed - Refrigerant lines lenght 5m

Heating: - Room air temperature 20C - Ambient air temp. 7C B.S. ; 6C B.U. - Maximun speed - Refrigerant lines length 5m

Dimensions (mm)

EFSI
090 H 670 750 235 17 EFSI 120 H 670 750 235 17 180 H 670 750 235 17

Height Width Depth Weight

A B C kg

CFSI 090 H 540 730 250 33

CFSI 120 H 540 730 250 33

CWI 181 H 540 780 265 37

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

385

Cod.: SEFSIUY.02 / 1301

CFSI_H CWI_H

MIH
MIH E MIHP071E MIHP091E MIHP121E

He at ing op e er Multisplit system heat pumps xt mo a e tio rn de MultiSplit System with capacities from 5.2 up to 8.4 kW with Inverter al n do w t wn emp ith er to at -1 5 ure C

Plasmacluster

Seasonal Energy Efficiency See Technical data

x3
MVIH

x4
= MIH E / MIHP E MFIH / MVIH MDIH E

MIHP181E

MDIH

MFIH

MIH C Regolamento (UE) N. 206/2012 Regolamento Delegato (UE) N. 626/2011

PLASMACLUSTER ionising filter (only for MIHP - MFIH - MVIH). Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them. Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air. The result is in the air: you can finally breath clean, odour-free ionised air.

Features
With R410A refrigerant Available in 3 different power versions Inverter technology for large power savings and optimized room comfort conditions Room reaches required temperature after switching on in 2/3 the time of an equivalent appliance without an inverter Excellent ratio between heating capacity and cooling capacity, thanks to the inverter-controlled compressor Three speed cross-flow fan Variable speed rotary compressor Optional indoor units among the following: Air outlet deflectors with horizontal adjustment MIH 071E - 091E - 121E facility MVIH 090E - 120E - 180E Motorized louver controllable from remote MDIH 070E - 090E - 120E (must be combined handset for vertical adjustment of outlet air with TL2I accessory)1) flow direction MIHP 071E - 091E - 121E - 181E (with Very quiet operation Plasmacluster) Infrared remote handset with LCD display for MFIH 071 - 091 - 121 (with Plasmacluster) full control of all functions of the appliance Trialsplit: MIH 183C outdoor unit which can be connected to 3 internal units Quadrisplit: MIH 244C outdoor unit which can be connected to 4 indoor units MIH 302C outdoor unit which can be connected to 4 indoor units, 180E/181E, combined with outdoor unit MIH302C, requires 3 indoor units instead of 4 Microprocessor control Local control facility Timer for programming On/Off times Programs for cooling only, heating only, dehumidification and automatic operation (heating/ cooling) Self-diagnostics function Easily removable, washable air filter with anti-mould treatmen Defrost control Refrigerant lines with flared ends Refrigeration lines up to 20m for the internal unit (max 50m for MIH 183C, max 50m for MIH 244C, max 50m for MIH 302C) Heating mode operation with external temperature down to -15 C

386

Technical data

Outdoor Units

Indoor Units* MIH - MIHP - MVIH MFIH - MDIH 09xE + 09xE + 09xE 12xE + 09xE + 07xE 12xE + 07xE + 07xE 09xE + 09xE + 07xE 09xE + 07xE + 07xE 07xE + 07xE + 07xE 09xE + 09xE + 09xE +09xE 12xE + 09xE + 07xE +07xE 09xE + 09xE + 09xE +07xE 12xE + 07xE + 07xE +07xE 09xE + 09xE + 07xE +07xE 09xE + 07xE + 07xE +07xE 07xE + 07xE + 07xE +07xE 18xE + 07xE + 07xE + / 18xE + 09xE + 07xE + / 18xE + 09xE + 09xE + / 18xE + 12xE + 07xE + / 07xE + 07xE + 07xE +07xE 07xE + 07xE + 07xE +09xE 07xE + 07xE + 09xE +09xE 07xE + 09xE + 09xE +09xE 09xE + 09xE + 09xE +09xE 07xE + 07xE + 07xE +12xE 07xE + 07xE + 09xE +12xE 07xE + 09xE + 09xE +12xE 07xE + 07xE + 12xE +12xE

Cooling capacity Input power nominal (min/max) nominal (min/max) kW 5,2 (2,2 / 7,2) 5,2 (2,2 / 7,2) 5,2 (2,2 / 7,2) 5,2 (2,2 / 7,2) 5,2 (2,2 / 7,2) 5,2 (2,2 / 7,0) 7,0 (3,0 / 8,2) 7,0 (3,0 / 8,2) 7,0 (3,0 / 8,2) 7,0 (3,0 / 8,2) 7,0 (3,0 / 8,2) 7,0 (3,0 / 8,2) 7,0 (3,0 / 8,2) 8,3 (4,3 / 8,9) 8,3 (4,3 / 8,9) 8,3 (4,3 / 8,9) 8,3 (4,3 / 8,9) 8,0 (4,3 / 9,0) 8,4 (4,3 / 9,0) 8,4 (4,3 / 9,0) 8,4 (4,3 / 9,0) 8,4 (4,3 / 9,0) 8,4 (4,3 / 9,0) 8,4 (4,3 / 9,0) 8,4 (4,3 / 9,0) 8,4 (4,3 / 9,0) kW 1,41 (0,43 / 2,56) 1,41 (0,43 / 2,56) 1,41 (0,43 / 2,56) 1,41 (0,43 / 2,56) 1,41 (0,43 / 2,56) 1,41 (0,43 / 2,46) 2,18 (0,60 / 2,98) 2,18 (0,60 / 2,98) 2,18 (0,60 / 2,98) 2,18 (0,60 / 2,98) 2,18 (0,60 / 2,98) 2,18 (0,60 / 2,98) 2,18 (0,60 / 2,98) 2,99 (1,07 / 3,49) 2,99 (1,07 / 3,49) 2,99 (1,07 / 3,49) 2,99 (1,07 / 3,49) 2,78 (1,07 / 3,49) 2,99 (1,07 / 3,49) 2,99 (1,07 / 3,49) 2,99 (1,07 / 3,49) 2,99 (1,07 / 3,49) 2,99 (1,07 / 3,49) 2,99 (1,07 / 3,49) 2,99 (1,07 / 3,49) 2,99 (1,07 / 3,49)

**

SEER

Heating capacity Input power nominal (min/max) nominal (min/max) kW kW 1,66 (0,42 / 2,48) 1,66 (0,42 / 2,48) 1,66 (0,42 / 2,48) 1,66 (0,42 / 2,48) 1,66 (0,42 / 2,48) 1,66 (0,42 / 2,48) 2,00 (0,56 / 2,56) 2,00 (0,56 / 2,56) 2,00 (0,56 / 2,56) 2,00 (0,56 / 2,56) 2,00 (0,56 / 2,56) 2,00 (0,56 / 2,56) 2,00 (0,56 / 2,56) 2,40 (0,94 / 3,06) 2,40 (0,94 / 3,06) 2,40 (0,94 / 3,06) 2,40 (0,94 / 3,06) 2,23 (0,94 / 2,85) 2,40 (0,94 / 3,06) 2,40 (0,94 / 3,06) 2,40 (0,94 / 3,06) 2,40 (0,94 / 3,06) 2,40 (0,94 / 3,06) 2,40 (0,94 / 3,06) 2,40 (0,94 / 3,06) 2,40 (0,94 / 3,06)

**

SCOP

183C

A+

244C

A++

302C

6,0 6,2 5,2 -

6,8 (2,2 / 8,4) 6,8 (2,2 / 8,4) 6,8 (2,2 / 8,4) 6,8 (2,2 / 8,4) 6,8 (2,2 / 8,4) 6,8 (2,2 / 8,4) 8,0 (3,0 / 9,2) 8,0 (3,0 / 9,2) 8,0 (3,0 / 9,2) 8,0 (3,0 / 9,2) 8,0 (3,0 / 9,2) 8,0 (3,0 / 9,2) 8,0 (3,0 / 9,2) 8,9 (4,4 / 10,5) 8,9 (4,4 / 10,5) 8,9 (4,4 / 10,5) 8,9 (4,4 / 10,5) 8,5 (4,4 / 9,8) 9,0 (4,4 / 10,6) 9,0 (4,4 / 10,6) 9,0 (4,4 / 10,6) 9,0 (4,4 / 10,6) 9,0 (4,4 / 10,6) 9,0 (4,4 / 10,6) 9,0 (4,4 / 10,6) 9,0 (4,4 / 10,6)

A+

A+

4,1 4,3 3,9 -

Data refer to total power with all units running. The technical manual contains the efficiency data of each unit. * = replace the x with 0 (zero) for MVIH - MDIH units and with 1 (one) for MIH E - MFIH - MIHP E units. ** =Energy efficiency class Trialsplit: It is necessary to install at least 2 indoor units to allow the system correct operation. Quadrisplit: It is necessary to install at least 3 indoor units to allow the system correct operation. MIH 071E 480 444 330 37 28 MVIH120E 666 534 405 40 26 MIHP 071E 480 444 330 37 28 MFIH 71 450 384 330 34 30 27 MDIH 70 300 270 220 37,5 35,5 29,5 MFIH121 624 522 432 39 36 30 MVIH 090E 573 486 378 38 25 MDHI120 520 410 320 36,5 32 26,5 MIH 241C 3120 56 1/4 3/8 MIH 091E 516 474 330 39 28 MIHP 091E 516 474 330 39 28 MFIH 91 522 438 366 38 34 29 MDIH 90 460 370 290 35 30 26 MIHP181E 864
726 570

Indoor Units Air ow rate Sound pressure Indoor units Air ow rate Refrigerant connections Outdoor Units Air ow rate Sound pressure m3/h (max.) m3/h (med.) m3/h (min.) dB (A) (max.) dB (A) (med.) dB (A) (min.)

m3/h (max.) m3/h (med.) m3/h (min.) dB (A) (max.) dB (A) (med.) dB (A) (min.) m3/h dB (A) liquid gas

MIH121E 588 510 414 40 29

MIHP121E 588 510 414 40 29

MVIH180E 864 714 531 44 35 MIH 244C 2580 49 1/4 3/8

43 39 MIH 302C 3120 57 1/4 3/8

Refrigerant connections

MIH 183C 1980 46 1/4 3/8

Power supply = 230V ~ 50Hz Performance values refer to the following conditions: e measured at 1.3m in an anechoic chamber. ee measured at 1m in an anechoic chamber. Cooling - room air temperature 27C D.B. ; 19C W.B. - ambient air temperature 35C ; maximum speed

Heating: - room air temperature 20C; - ambient air temperature 7C D.B. ; 6C W.B. ; max.speed

387

Accessories
AMP BC DSC GA GAF GM MA MU PA MDIH 4* 5** 8 4 22 32 42 22 32 42 22 32 42 22 32 42 22 32 42 22 32 42 22 23 32 33 42 43 22 32 42 22 32 42 22 32 42 22 32 42 22 32 42 20X 30X 40X 2 I *** 5 7
** =in combination with accessory MU

070

090

120

PC

PM RD RDA RP RPA SE TL ZX

* = in combination with accessory MA

*** = It is a mandatory accessory because the units are consigned without MDIH

AMP: Kit for ceiling mounting. BC: Auxiliary condensate drip tray. DSC : Condensate drainage device for use when natural run-off is not possible. GA: Intake louver with fixed slats. GAF: Intake louver with fixed slats and filter. GM: Delivery louver with adjustable slats. MA: Vertical cabinet. MU: Universal cabinet. PA: Intake plenum in galvanized steel, with

plastic outlet connections for circular section SE: Manually operated fresh air intake louver. ducting. TL2I: Infrared remote handset with LCD PC: Rear cover panel. display for full control of all appliance fun PM: Delivery plenum in galvanized steel with ctions. Kit including receiver for wall installaexternal insulation, with plastic outlet contion. (Obligatory accessory). nections for circular section ducting. ZX: Feet for floor standing installation of RD: Delivery straight duct connection. models with MA accessory; or built-in instal RDA: Intake straight duct connection. lation. RP: Delivery 90 duct connection. RPA: Intake 90 duct connection.

388

Dimensions (mm)

MIH E MFIH MDIH

MIH C
B C

MIHP 071 E MIHP 091 E MIHP 121 E

MIHP 181 E MVIH

Mod. MIH MIHP MFIH MVIH MIH MIHP MFIH MVIH MIH MIHP MFIH 071E 071E 071 090E 091E 091E 091 120E 121E 121E 121 Height A 278 278 680 670 278 278 680 670 278 278 680 Width B 790 790 1025 750 790 790 1025 750 790 790 1025 Depth C 198 198 212 235 198 198 212 235 198 198 212 Weight kg 10 10 31 17 10 10 31 17 10 10 31 Mod. MVIH MIHP MIH MIH MIH 180E 181E 183C 244C 302C Height A 670 325 645 800 800 Width B 750 1040 950 950 940 Depth C 235 229 323 357 320 Weight kg 17 16 53 64 70

MDIH 070 - 090 - 120 MDIH 070 090 120 A 457 457 457 B 592 823 1043 C 216 216 216 D 440 671 891 E 453 453 453 F 41 41 41 G 101 101 101 H 74 74 74 L 260 260 260 M 144 144 144 N 49 49 49 P 522 753 973 Weight [Kg] 17 23 26

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

389

Cod.: SMIHUY.19 / 1301

PSD
R410A

Portable air conditioner with remote control

Features
Mono tube portable air conditioner with high energy efficiency (A Class) Air conditioner for indoor installation The air conditioner is mounted on wheels, can be used in different rooms and is easy to transport and install For immediate use just insert the air outlet flexible pipe between the shutters of a window The air conditioner can also be installed in a fixed manner by making a hole (150 mm) in the wall or glass and can be removed when not required The same air conditioner can be installed in a fixed manner in a number of rooms, all that is required is a hole (150 mm) in each room Dehumidifying the room requires no particular installation - remove the flexible pipe from the air conditioner and the windows and doors in the room must be closed Infrared remote control with liquid crystal display to control all functions. Using it is simple and immediate The control panel with a display on the air conditioner allows simple and immediate use Microprocessor control Functioning mode: Cooling, Dehumidifying, Auto, Ventilation only Programmable switch-on/off timer Night time well-being program Plastic cover cabinet High efficiency rotary compressor Silent functioning Automatic expulsion of condensate in cooling mode Full tank indicator Possibility of manual draining of the condensate Three-speed ventilation The cool and/or dehumidified air is emitted through the front grid and travels in a horizontal as well as vertical direction through louvered mobile fins. The air to be treated is drawn in from the rear and side through the filters The warm air is expelled through a flexible pipe that must be applied with the special flange on the rear side of the air conditioner Regenerative air filters Automatic restore function in case of a power failure Electric power supply cable with plug

390

Technical data
Mod. Cooling capacity Humidity removed Input power Fan speed Air flow rate Compressor Refrigerant Gas load (R410A) Lenght of flexible pipe (min / max) Sound pressure Protection rating min med max min average max PSD 090 2,6 0,95 1000 3 250 300 350 Rotary R410A 0,48 0,5 / 1,5 52 54 56 IP20

kW l/h W n m3/h m3/h m3/h kg m dB(A) dB(A) dB(A) -

Power supply = 230V ~ 50Hz The performance refers to the following conditions: Mono tube installation Maximum speed Sound pressure measured in a semi anechoic chamber, 1m from the front Cooling - Environment air temperature (evaporator) 35C B.S. ; 24C B.U. - External air temperature (condenser) 35C B.S. ; 24C B.U.

Dimensional data (mm)

790

300

340

Weight

kg

PSD 090 26,5

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com

391

Cod.: SPSDUY.01 / 1007

Smuffo

Dehumidifier

Smuffo is harmless for the ozone layer because it uses R134a, the ecological CFC-free refrigerant.

DMF

Features
Smuffo is a dehumidifier designed to removes excess humidity from room air. Smuffo is the ideal solution against condensation water, moulds and the health problems they bring, because its stops them at the source. The cabinet has a modern design and is completely white. The desired operating mode is selected by using the controls. Effective: Dries up damp walls and eliminates excess air humidity before it can condense on cold room surfaces. Pratical: Portable and compact-sized, Smuffo fits in discreetly and requires very little maintenance. Clean the filter using a soft brush and hot, soapy water, and let dry before refitting. Condensate water is collected in an adequately sized tank or continuously removed by draining. User friendly: Simply plug Smuffo into a socket and set the desired functions. Coil defrosting is completely automatic. Smuffo will work quietly to improve your health.

392

Technical data
Mod. Moisture removed Sound pressure Air flow rate Tank capacity Total input power Total input current Refrigerant Power supply = 230V ~ 50Hz Performance values refer to the following conditions Sound pressure level (weighted A) measured in a room with 85m3 volume , reverberation time t = 0,5s direction factor Q = 2 ; distance r = 2,5m Dehumidification: Room air temperature D.B.=30C ; room air temperature W.B.=27C l/24h max. dB(A) max. m3/h med. m3/h min. m3/h l W A DMF 12 12 41,5 100 89 78 5,5 250 1,1 R134a DMF 20 20 48 125 111 98 5,5 400 1,76 R134a

Dimensions (mm)

DMF

Height Width Depth Weight

A B C kg

DMF 12 545 380 261 12,5

DMF 20 545 380 261 14

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

393

Cod.: SDMFUY.00 / 1010

NEW

CWX
R410A

Water cooled condensing unit Cooling only operation Internal installation with capacity from 3.5 to 6.7kW

Accessory TL 3

Accessory PF

CWX

EXC

EWP

Plasmacluster

EWA_H

The internal units EWP and EWA_H are supplied with the ioniser lter PLASMACLUSTER. Plasmacluster is capable of breaking down contaminants, decomposing the molecules. By electrical discharges "Plasmacluster" causes the water molecules present in the air to be split into positive and negative ions. These ions neutralise the molecules of gaseous contaminants achieving products normally present in clean air. The result is in the air: nally you can breathe air cleaned, ionised and without bad odours.

Characteristics
Available in 3 versions of different capacities The versions are manufactured with refrigerant R410A (CWX1200, CWX1800, CWX2400) Operates as cooling only with condensation by water CWX condensing unit with rotary compressor EXC: internal unit with three speed centrifugal fan with the possibility to modify the electrical connection to increase the available static pressure. Mandatory accessory PF(wired panel) or TL3 (remote controller), required for the operation of the unit EWA_H - EWP: internal unit with three speed tangential type fan. Horizontally adjustable discharge louvres and motorised deflector louvres, actioned by the remote controller for vertically adjusting the supply air Infra red remote controller with liquid crystal display. Extremely low noise operation Microprocessor controller Timer programmed delay start and stop Programmes for cooling only, heating only, dehumidification, automatic operation (heating/cooling) Washable filter easily removed and with anti mould treatment Flare type refrigerant connections Refrigerant lines up to 15m Vast range of accessories available for the internal unit EXC

394

Technical data
CWX Cooling capacity Total power input Total current input Water use at 16C Water use at 30-35C e Sound pressure Refrigerant Refrigerant connections Refrigerant lines EXC Heating capacity (electric heater) Condensate drain rate EER Energy efciency class Current input (electric heater) Heating capacity with water coil* Internal unit air ow e e Sound pressure Refrigerant connections EWA Condensate drain rate EER Energy efciency class Air flow W W A l/h l/h dB(A) liquid gas liquid gas W l/h W/W A W (min.) m3/h (med.) m3/h (max.) m3/h (min.) dB(A) (med.) dB(A) (max.) dB(A) liquid gas l/h W/W m3/h (min.) m3/h (med.) m3/h (max.) dB(A) (min.) dB(A) (med.) dB(A) (max.) liquid gas l/h m3/h (min.) m3/h(med.) m3/h (max.) dB(A) (min.) dB(A) (med.) dB(A) (max.) liquid gas 1200 3500 795 3.58 140 706 47.5 1/4 1/2 1/4 1/2 123 1650 1.4 7.2 3800 310 400 520 29.0 34.5 39.0 1/4 1/2 120 H 1.2 4.40 A 210 396 438 28 33 37 1/4 1/2 1800 5100 1370 6.34 235 1082 50.5 R410A 1/4 1/2 1/4 1/2 183 1950 1.78 3.72 A 8.5 5000 550 650 840 43 46.5 50 1/4 1/2 2400 6700 1940 1.4 345 1450 50.5 1/4 5/8 1/4 5/8 243 2200 2.3 3.45 B 9.6 6700 610 830 960 41 45 48 1/4 5/8 -

e Sound pressure Refrigerant connections EWP Condensate drain rate Air flow

181 H 1.6 798 954 1068 37 42 45 1/4 1/2

241 H 2.2 798 954 1068 37 42 45 1/4 1/2(*)

e Sound pressure Refrigerant connections Power supply = 230V ~ 50Hz

Performances relate to the following conditions: Sound pressure measured in a semi-reverberant room of 85m 3 and reverberation time Tr = 0.5s e e Sound pressure measured in an anechoic chamber at 1.3m distance and directivity factor 4

Cooling: - ambient air temperature 27C Db / 19C WB - external air temperature 35C - maximum speed

* = Apply the connection (1/2F - 5/8M) supplied loose with the condensing unit CWX 2400 to the refrigerant connections of unit EWP H

Accessories
Mandatory accessory PF or TL3 are required for the operation of the unit EXC: PF: Control panel with ambient electronic thermostat for wall mounting. It is a mandatory accessory since the EXC unit is shipped without. TL3: Infra red remote controller with liquid crystal display for the control of all functions Kit complete with recess mounted base. It is a mandatory accessory since the EXC unit is shipped without. AMP: Hanging installation kit. BC: Auxiliary condensate drain pan. BV: 1 row hot water coil. DSC4: Condensate pump for overcoming lift. GA: Intake grille with fixed louvres. GAF: Intake grille with fixed louvres and filter. GM: Supply grille with adjustable louvres. MA: Enclosure Alto. MU: Enclosure Universale. PA: Suction plenum in galvanised sheet steel, complete with supply connections in plastic for circular duct connections. PC: Sheet steel panel for enclosing the rear part of the unit. PM: Discharge plenum in galvanised steel, externally insulated, with supply connections in plastic for circular duct connections. RD: Discharge straight connection for ducting. RDA: Suction straight connection for ducting. RP: Discharge connection 90 for ducting. RPA: Suction connection 90 for ducting. RX: Shielded electric heater coil with safety thermostat. SE: External air manual damper. SW: Sensor that permits unit operation only with temperature above 35C. VCF: Kit consisting of 3 way motorised valve, connections and copper tubes. ZX: Feet for floor mounting for models with the accessory MA, or recess mounting.

395

Accessory compatibility CWX 1200 EXC 123 **** CWX 1800 EXC 183 **** CWX 2400 EXC 243 ****

TL PF AMP

3 *** *** 4* 5** 6** 8 9 122 132 142 162 4 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 22 23 32 33 42 43 62 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 22 32 42 62 070 090 120 180 180 T 240 240 T 20X 30X 40X 80X 3 44 45 5 6 7 8

BC

BV DSC GA

GAF

GM

MA

MU

PA

PC

PM

RD

RDA

RP

RPA

RX

SE SW VCF

ZX

* = in combination with accessory MA

** = in combination with accessory MU

*** = Is a mandatory accessory in that the EXC unit is shipped without

**** = The VCF valve and the BC4 drain pan cannot be installed simultaneously on the same unit.

396

Dimensional data (mm)


EXC 123 - 183 EXC A B C D E F G H L M N P Weight (kg) 123 457 1043 216 891 453 41 101 74 260 144 49 973 26 183 457 1043 216 891 453 41 101 74 260 144 49 973 27 243 562 1182 216 1102 558 41 107 68 273 253 32 1122 37

EXC 243

EWP Height Width Depth Weight

A B C kg

181 H 325 1040 229 16

241 H 325 1040 229 16

EWP

EWAH Height Width Depth Weight

A B C kg

070 H 270 810 184 9

090 H 270 810 184 9

120 H 278 790 198 10

EWAH

A B C kg

CWX
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293730 www.aermec.com

397

Cod.: SEXCUY.16 / 1301

CWX Height Width Depth Weight

1200 450 470 260 35

1800 450 470 260 38

2400 570 470 260 49

NEW

FW-R
R410A

Water-cooled air conditioners with capacities from 2.9 up to 4.0 kW

TL 3 Mandatory accessory

FW-R series integrated system air conditioners are independent appliances designed and built to create and maintain optimum room comfort conditions. Discreetly and elegantly styled, these remarkably quiet units are ideal for installation in the home or commercial premises. Equipped with a water-cooled condenser, FW-R appliances perform all typical cooling, dehumidification, ventilation and air filtration functions while offering particular benefits in terms of ease of application and installation.

Suitable also for winter operation when equipped with an electric heater or hot water coil; console air conditioners are able to provide different microclimates within the same room because each appliance can be adjusted independently; low running costs are assured by fast arrival at the required room temperature because of the low thermal inertia of the system; quiet operation and thermal efficiency are also promoted by the heat and sound insulation of the compressor bay. All appliances are factory assembled and individually tested.

Features
High efficiency rotary compressor Compact size Quiet operation Automatic temperature adjustment Reduced water consumption Low electrical power consumption

Accessories
TL3 : Mandatory accessory, remote controller, BR: Armoured heating element with safety BVR: Single row hot water coil. required for the operation of the unit thermostat.

FW TL 3 BR 26 BVR 1

Compatibility of accessories 130R 160R


398

Technical data
Mod. Cooling capacity Energy Efciency Class EER Humidity removed Input power Input current Heating capacity with water coil (BVR1) Water flow rate (BVR1) Pressure drops (BVR1) Heating capacity electric coil (BR26) Fans Air ow rate FW W (max.) 130R 2900 A 4.08 1.78 710 3.55 4350 600 12,6 1200 2 470 390 270 800 660 500 44 586 22 750 1120 4.97 18 1/2F 160R 4000 A 4.65 1.78 860 4.02 5200 600 12,6 1200 2 690 525 375 1140 885 665 47,5 804 40 830 1500 6.65 32 1/2F

Fans speed Sound pressure Water consumption at 30-35C Condenser pressure drops Refrigerant charge R410A Input nominal power consumption * Nominal imput current * Input current Water connections Power supply = 230V ~ 50Hz.

l/h W A W l/h kPa W n. m3/h (max.) m3/h (med.) m3/h (min.) g/m (max.) g/m (med.) g/m (min.) dB (A) l/h kPa g W A A

Sound pressure measured in an 85 m 3 semi-reverberant test chamber with reverberation time Tr = 0.5s. * In accordance with UNI EN-60335 Data declared in accordance with EN-14511 Cooling - Room air temperature 27C B.S. ; 19C B.U. - Entering water temperature 30C - Leaving water temperature 35C - Max speed

Heating (BVR1) : - Room air temperature 20C - Entering water temperature 70C - Max speed

Dimensions (mm)

Height Width Depth Weight

A B C Kg

FW 130 R 723 1121 242 63

FW 160 R 723 1121 242 67

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com

399

Cod.: SFWRUY.06 / 1303

DISTRIBUTORS / DISTRIBUTEURS
ALBANIA AERMEK ALBANIA SH.P.K. - Bul. Zhan DArk Kulla 4 - TIRANA- Tel. +355 4 2224339 - Fax. +355 4 2224339 - tltsystem@albmail.com ALGERIA AIRMEC ALGERIE - 312 Avenue Hamid Kebladj - Hammamet - Tel. + 213 21 957 883 - Fax + 213 21 958 036 - airmec_algerie@yahoo.fr AUSTRALIA COSAIR PRODUCTS PTY LTD - Unit 10, 35 Birch Street - Condell Park NSW 2200- Tel. +61 297964668 - Fax +61 297964669 mcosgrove@cosair.com.au AUSTRIA AERSYS GMBH - Anton-Freunschlag Gasse 72 - 1230 Wien - Tel. +431 6991967 - office@aersys.at AZERBAIJAN NEP ENGINEERING - Nizami 86/7 - Baku - Tel./Fax. +99 412 4934560 - nep@nep.az - perviz@ozulinsaat.com - k.secher@nep.com.tr BELGIUM ENERWIN S.P.R.L. - Chausse de L'Herbatte, 38 - 1300 WAVRE - Tel. +32 02 3671920 - Fax +32 02 3671920 - info@aermec-be.be BOSNIA AND HERZEGOVINA TAURUS D.O.O.- UL. Medresa BR. 4 - 71270 FOJNICA - Tel. +386 40298682 - Fax +387 33524738 - marko.moldovan@gmail.com BIELORUSSIA AEPMEK-BEL Ltd. - 115, Mayakovskogo str. - Minsk - Tel. 375 295018323 - Tornado-ASL@yandex.ru BULGARIA ATARO CLIMA EOOD - 272 Vasil Levski str. - Plovdiv - Tel. +359 32 906 906 - Fax +359 32 906 900 - ataro@ataro.bg RATOLA INZHENERING - Ul. Topli Dol. 3ET.1AP.1 - GR. Sofiya - Tel. +359 2 9691031 - Fax +359 2 9691020 - office@ratolabg.com CANADA MITS AIR CONDITIONING Inc. - 1608 Bonhill Road - L5T 1B451 Mississauga ONTARIO - Tel. +905 564 2221- Fax + 905 564 2205 jchaters@mitsair.com CROATIA MARITERM d.o.o. - Drazice 123D, Zamet - 51 000 Rijeka - Tel. +385 51 815010 - Fax +385 51 815011 - mariterm@mariterm.hr CYPRUS ROYAL ENGINEERING CO. LTD - 6 Trachona Str. - Dhali Industrial Area - 1662 Nicosia - P.O. Box 20689 - Tel. +357 22612199 Fax +357 22610272 - royaleng@cytanet.com.cy CZECH REPUBLIC COMPLETE CZ spol. s.r.o. - Legerova 1853/22 - Praha 2 - Tel. +420 246 030029 - Fax +420 246 030032 - info@completecz.cz DENMARK H. JESSEN JURGENSEN A/S - Tempovej 18-22 - 2750 Ballerup - Tel. +45 70 270607 - Fax +45 70 263405 - jeo@hjj.dk EGYPT EBIARY ENGINEERING COMPANY- 1-B, Makraam Ebeed St. - Nasr City - CAIRO - Mob. +20101350232 - Fax +202 22743550 ebiarydct@yahoo.com ENGLAND AERMEC UK LIMITED - 288 Bishopsgate - London - EC2M 4QP - Tel. +44 0203 008 5940 - Fax +44 0203 008 5941 - uksales@aermec.co.uk FINLAND HUURRE FINLAND - Taivaltie 5 - 01610 Vantaa - Tel. +358 20 5555897- Jari.Vanhala@huurre.com FRANCE AERMEC SAS - PARC VISIONIS II - Rue du Developpement - 01090 GUEREINS - Tl. +33 04 74090038 - Fax +33 4 74090988 info@aermec.fr AERMEC SAS - AGENCE SILLON ALPIN - Immeuble Le Dauphin 18 Alee du LAc St. Andre - 73382 Le Bourget du Lac Tel. +33 04 79 65 46 00 - Fax +33 04 79 65 41 77 - jerome.dubouchet@aermec.fr AERMEC SAS - Ile de France - 80 Avenue du Gnral De Gaulle - 91170 Viry Chatillon - Tel. +33 1 60478348 - Fax +33 1 69436368 gianni.defabbro@aermec.fr Chaud Froid National - 4 rue Nicphore Niepce - 76300 Sotteville les Rouen - Tel 02-32-76-88-81 - Fax 02-32-76-88-89 laurent.guidez@chaudfroidnational.fr DIMENA SARL - 88 Rue Du Moulineau - 33320 Eysines - Tel. +33-5-57876429 - Fax +33-5-56798900 - contact@dimena.fr DIMENA - 6 Rue Maurice Hurel - Parc de la plaine - 31500 Toulouse - kriva@dimena.fr S.TE FRANCE CLIM - 41 rue Pierre Smard - 57300 Hagondange - Tel. +33 3 87517505 - Fax +33 3 87517514 - france.clim@laposte.net PHOENIX CLIMATISATION - 8, Rue de Paris - 92190 Meudon - Tel. +33 01 41 14 41 91 - Fax +33 01 41 14 52 21 rponcet@phoenix-climatisation.fr T.C.A. - Avenue des Maurettes - 06270 Villeneuve Loubet - Tel. +33 4 92133666 - Fax +33 4 93208304 - tca06@tca.fr T.C.A. - 19 Rue M. Basti Z.I. de la Lauze - 34430 St Jean De Vedas - Tel. +33 4 67473690 - Fax +33 4 67479851 - tca34@tca.fr T.C.A. - 213 route de la Valentine aux 3 lucs -13011 Marseille - Tel. +33 4 91191919 - Fax +33 467479851 - tca13@tca.fr GEORGIA Saga Impex Ltd.- 2-4-6-8-10 Chachava Street, 0159 Tbilisi - Georgia - Tel: +995 32 540717/27/37/47 - Fax: +995 32 541727 shalva@sagaimpex.ge GERMANY AERMEC GmbH - Im Tal 10 - 87669 Rieden Am Forggensee - Tel. +49 8362 300600 - Fax +49 8362 3006060 - info@aermec.de NOVATHERM KLIMAGERTE GmbH - Am Gierath 4 - 40885 Ratingen - Tel. +49 2102 91000 - Fax +49 2102 910010 - ratingen@novatherm.de NOVATHERM KLIMAGERTE GmbH - Dieselstrasse 40 - 30827 Garbsen-Berenbostel - Tel. +49 5131 49670 - Fax +49 5131 496767 hannover@novatherm.de GREECE CALDA ENERGY S.A.I.C. -100 Tatoiou Str, Metamorfossi -14452 Athens - Tel/Fax +30 210 28 43 - Fax + 30 210 28 43 - calda@otenet.gr HOLLAND HOLLAND CONDITIONING B.V. - Tielenstraat 19 - 5145 RC Waalwijk - Tel. +31 416 650075 - Fax +31 416 650586 algemeen@holland-conditioning.nl HUNGARY OKTOKLIMA - Kirlyok tja 27 -1039 Budapest - Tel. +36 1 4332360 - Fax +36 1 2403617 - oktoklima@oktoklima.hu IRAN PIONEER MIDDLE EAST CO. - 643, West Sanabad Ave. - Mashad - Tel. +98 5118457722 - Fax 98 5118411627 - eng@middleasthvac.com IRELAND European Industrial Chillers Limited - Unit 74 Dunboyne Business Park - Dunboyne Co. Meath - Tel. +353 01 8255155 - Fax +353 01 8255188

VERTRIEBSPARTNER / DISTRIBUIDORES
ISRAEL ERES REFRIGERATION & ENGINEERING MANUFACTURE & SERVICE LTD - 27 Ha'Charoshet St. Ind. Zone Karmiel, P.O.B. 69 - 21610 Karmiel Tel. +972 4 9987043 - Fax +972 4 9985915 - eresrfrg@netvision.net.it NORTH IRELAND Please contact Aermec Spa - Via Roma, 996 - 37040 Bevilacqua (VR) - Tel. +39 0442 633111 - sales@aermec.com KAZAKHSTAN AEPMEK KAZAKHSTAN - Samal-2, 59, Blok B, office 19 - 050040 Almaty - Tel. +77272668648 - info@aermek.kz AEPMEK KAZAKHSTAN - Business Center Ansar 3rd floor, office VP Siganak Street 25, - 010000 Astana - Tel. +77172550748 info@aermek.kz LITHUANIA NIT Ltd - Savanoriu-Pr 151- 03150 Vilnius - Tel. +370 5 2728552 - Fax +370 5 2728559 - andrius@nit.lt LUXEMBOURG CLIMAX LUXEMBOURG SARL - 7 Rue Lankelz - L 4205 Esch Sur Alzette - G.D. of Luxembourg - Tel. +352 26 176615 - Fax +352 26 176625 info@climax.lu MACEDONIA D.O.O. EUROTERM - UL. Sotka Georgieski Br. 63 - 7500 PRILEP - Tel. +389 48419415 - Fax +389 48422981 - info@euroterm.com.mk MALTA ENGENUITY LTD - 8 Triq Tal HIas - Qormi Qrm5011 - Tel. +356 21490957/8 - Fax +356 21490964 - alan.abela@engenuity.com.mt MOLDOVA SC LERAI GROUP - Via Bulgara, 18 - Chisinau MD-2001 - Tel. +373 22 224238 - Fax +373 22 233024 - info@lerai.md MOROCCO ECOTHERM SARL - 67, Rue du Lieutenant MAHROUD ex Rue Chevalier BAYARD - Casablanca 20300 - Tel. +212 522 243300 Fax +212 522 243302 - contact@ecotherm.ma NEW ZEALAND Energy Products International - 30 Gallagher Drive - Frankton Hamilton 3243 - Tel. +64 7 839 2705 - Fax: +64 7 834 4212 epi.sales@energy-products.co.nz NORWAY NOVEMA KULDE AS - Marenlundveien 5 - 2020 Skedsmokorset - Tel. +4769367190 - Fax +4769367191 - trond.kristensen@novemakulde.no NOVEMA KULDE AS - Stabburveien 8 -1601 Fredrikstad - Tel. +47 69 367190 - Fax +47 69 367191 - espen.spondalen@novemakulde.no NOVEMA KULDE AS - J Brochs gate 12 inng B - 5006 Bergen - Tel. +47 55 348675 Fax +47 55 348675 - bjorn.vassbotten@novemakulde.no NOVEMA KULDE AS - Sorgenfrivn 9 - 7037 Trondheim - Tel. +47 73 820890 - Fax +47 55348675 - jon.lines@novemakulde.no POLAND TEOMA S.A. - ul. Majdanska, 3 - 04-088 Warszawa - Tel. +48 22 517 7900 - Fax +48 22 5177901 - teoma@teoma.pl PORTUGAL CEST COMRCIO E INDSTRIA, LDA Av. Almirante Gago Coutinho - Ouressa Parque - Arm. 13, 2725-322 Mem Martins Tel. +351 219253330 Fax +351 219253338 geral@cest.pt RUMANIA AIRMEC ROMANIA S.RL. - 29 lezeru Street, Sector 1 - Bucharest - Tel. +40 21 550866589 - Fax +40 21 3260973 - airmec@adslexpress.ro RUSSIA AERMEC Spa - Rep. Office Business Center Capital Plaza, 4 Lesnoy Pereulok - office 455 - 125047 Moscow - Tel. +7 495 6638044 m.l@aermec.com SERBIA & MONTENEGRO AKTING DOO - Jurija Gagarina, 153/32 -11070 Novi Beograd - Tel. +381 113187383 - Fax +381 113187387 - akting@eunet.rs SLOVAKIA KLIMA TEAM s.r.o. - Trnavska 63 - 82101 Bratislava - Tel. +421 2 43293969 - Fax +421 2 43420079 - mail@klimateam.sk SLOVENIA BOSSPLAST D.O.O. - Pod Jelsami 5 -1290 Grosuplje - Tel. +386 1781 0550/5 - Fax +386 1781 0560 - jernej.rode@bossplast.com SOUTH AFRICA APOLLO AIR CC - Unit 4, 10 Cabernet Str - Saxenburg Park, Kuilsriver - 7562 Cape Town - Tel +27 21 9057979 - Fax +27 21 9057976 carlo@apolloair.co.za SPAIN AIRLAN S.A. - Ribera de Deusto 70 - 48014 Bilbao - Tel. +34 94 4760139 - Fax +34 94 4752402 - rcoteron@airlan.es AIRLAN - Pol. lnd. La Grela C/Ermita 48 -15008 La Coruna - Tel. +34 981 288209 - Fax +34 981 286503 AIRLAN - C/Arganda 18 - 28005 Madrid - Tel. +34 91 4732765 - Fax +34 91 4732581 AIRLAN - Avda Meridiana 350 4A - 08020 Barcelona - Tel. +34 93 278 06 20 - Fax +34 93 278 02 24 AIRLAN - C/ Acueducto 24 - Edif. Dos Hermanas Isla Edificio 2, Pl 1, Mod. 9 - 41703 Pol. Ind. Ctra. De la Isla, Sevilla (Sevilla) Tel. 955 540 612 - Fax 901 706 015 AIRLAN - Pol. lnd. Son Castello C/Teixidors 30, Nave 5 - 07004 Palma De Mallorca - Tel. +34 971 706500 - Fax +34 971 706372 AIRLAN - C/Los Bimbaches 13 - 38007 Santa Cruz de Tenerife (Isole Canarie) - Tel.+34 922 21 4563 - Fax +34 922 7985 SYRIA SINJAB TRADING EST - Murshe Khater st. PO BOX 5358 - 5073 Damascus - Tel. +963 11 4424541 - Fax 963-11-4412862 - sinjabest@gmail.com SWEDEN KYLMA AB - Box 8213 -163 08 SPNGA, Tel. +46 8 59890805 - Fax +46 8 59890891 - Mikael.Magnusson@kylma.se AIRCOIL AB - Angsvagen 22 - 67232 ARJNG - Tel. +46 573 711045 - Fax. +46 573 711811 - info@aircoil.se SWITZERLAND TCA THERMOCLIMA AG - Piccardstr. 13 - 9015 St. Gallen - Tel. +41 71 313 99 22 - Fax +41 71 313 99 29 - info@tca.ch TCA THERMOCLIMA AG - Gewerbestr. 10 - 4528 Zuchwil - Tel. +41 71 313 99 22 - Fax +41 71 313 99 29 - info@tca.ch TCA THERMOCLIMA SA - Av. Boveresses 52 - 1010 Lausanne - Tel. +41 71 313 99 22 - Fax +41 71 313 99 29 - info@tca.ch KATALTHERM SERVICE S.A. - Via alla Gerra, Cp 54 - 6930 Bedano - Tel. +41 91 935 22 22 - Fax +41 91 935 22 24 katalthermservice@ticino.com TUNISIA CODIFET S.A.R.L. - 7 Rue de la Chimie Z.I. SIDI REZIG - 2033 Megrine - Tel. +216 71 433035 - Fax +216 71 433239 - codifet@planet.tn TURKEY ALDAG DIS TICARET AS - Dereboyu Sok. Sun Plaza Kat:13 - 34398 Maslak /Istanbul - Tel. +212 366 5806 - Fax +212 366 58 55 serkansozen@aldag.com.tr UKRAINE AERMEK UKRAINE LLC, - Vorovskogo Str., build. 37/14 off. 304 - 01054 Kyiv 054 - Tel. +380 44 390 73 47 - Fax +380 44 390 73 46 apo@aermec.com.ua