Sie sind auf Seite 1von 6

VADODARA ZONE NOTICE INVITING TENDER ELECTRICAL AUDIT OF THE BRANCHES

Bank of India invites sealed tenders for electric audit for branches and offices in Vadodara Zone in the state of Gujarat, from the authorized electric consultant/electrical firm/empanelled electric engineers who full fill the following requirements1) Must have an established office any where in Gujarat. 2) The firm must have at least 05(five) years experiences in the same field. 3) The minimum educational qualification of an electric auditor/consultant should be a diploma holder in electrical engineering (DEE) Or retired electrical engineer from Govt., sector or PSU sector or private organization. Bachelor degree of electrical engineering and higher qualification will be an added advantage. 4) Must have valid sales Tax number 5) PF registration (If applicable) 6) ESI registration (If applicable) 7) Must have field income tax return at last 03(Three) years 8) The firm must have a minimum turnover of Rs 05 lacks per year for last three years. 9) The consultant/firm should be certified with license from appropriate authorities like state electric board. 10) The firm must be having at least two (02) running contract with a PSU/any other organization in electrical installation/electric audit or similar electric work done preferably the Banks (in the state where ZO is located). 11) The bids (Only Annexure I And Annexure III) should reach Bank of Indias Zonal Office, Vadodara by 28th July 2012 before 1.00 PM. Technical Bid And Financial Bids in separate sealed envelopes be put in a third envelope marked Tender - Electrical Audit Annexure II is not to be submitted with the tender documents as it is a Format which is to be used for conducting the Electrical Audit and them submitting the report for the same at Zonal Office. N.B. a) The relative documentary proof in respect of above conditions/ requirements should be enclosed with tender without which the tender will be summarily rejected. The Vendors fulfilling the above conditions may apply in TWO BID SYSTEM i.e. Technical Bid and Financial Bid. Interested vendor may either collect the Tender Forms from Bank of India, Zonal Office, Vadodara against the payments of Rs 500.00, in form of a DD payable to Bank of India, or download the same from the banks website (during 14.07.2012 to 28.07.2012) and deposit the amount along with tender documents by way of DD/Pay Order.

To be submitted in an envelope marked Cover No 1 - Technical Bid

Annexure I
Form A TECHINICAL BID FOR ELECTRIC AUDIT OF BRANCHES AND OFFICES 1. Name of Firm 2. Address 3. Established Since 4. Name of Proprietor/Partners 5. Whether firms are registered in State Electricity board or other related department. (Give name of board/dept. with address) 6. Registration no./ License No. with date 7. Name of electric engineer/auditor/inspector : 8. Qualification of electric engineer/auditor /inspector : : : : :

: :

(Qualification at least diploma holder in electric engineering or retired electrical engineer from govt., PSU or private organization) : 9. Details of running contacts with other Organizations with amount of work order 10. Details of two (02) work order of similar work, preferably with PSU/ Banks 11. Details of staffs who provide the service with contact no. (Attach separate list of staffs with qualification) : :

Signature/Seal Place: Date: Note: Please submit relevant photocopies of Registration / license / experience /work order or other relevant document for above said declaration.

Annexure II
FORMAT FOR ELECTRIC AUDIT OF BRANCHES/OFFICES
1.1 General informationSr. 01 02 03 04 05 06 07 08 09 Details Remarks Name of branch with full address and zone Type of branch (Metro/Urban/Semi-Urban/Rural) Name of power supply company / department Name of electric auditor/inspector/ Date of visit of auditor Sanctioned load for branch/offices by the state electricity board Average load consumption by the branch(From last six months) Is there any irregular breakdown/ power tripping (frequent/occasional/very rarely) Is there any penaltypay by branch/office in last six month( Yes/No) (if Yes then give details)

1.2 Mandatory checklist of electric equipmentSr. 01 02 Details Remarks Conditions of cabling carried out in the premises (Good/medium/Poor)( if poor give suggestion) Whether appropriate rating of cables have been used in the premises for installed electric equipment (Including false ceiling) (Yes/No)(If No give suggestion) Any clubbing of installations in one point. (yes/No) (If yes give location and suggestion) MCB/Master switch is installed in prominent place and is in working condition( Yes/No)(If No then give suggestion) Installed MCB/Master switch are in proper rating (Yes/No) (If No then give suggestion for proper rating MCB/Master switch) Any ELCB are installed in branches (Yes/No) (If No then give suggestion) Electric Load (KWs) a) Phase-I b) Phase-II c) Phase III (If any overload found in phase / consumed load is more than capacity than give full details with corrective suggestion)

03 04

05

06 07

08

09

10

11

12

13

14 15 16 17

Voltage (In Volts) a) R- phase (R-N) b) Y-phase (Y-N) c) B-phase (B-N) (If existing voltage is high or low as per requirement then give full details with suggestion) Whether any generator is kept inside the bank premises. (Yes/No) (If yes then give full details- make, capacity, date of manufacturing etc.) Whether condition of batteries, coolant and rpm of generator are in proper condition? (Yes/No) (If No then then give suggestion) Whether the connection between main power supply to Generator is appropriately connected. (Yes/No) (If No then give suggestion) Nos. of electric equipmenta) Tube light b) Fan c) Electric pod for computer d) Printers e) Passbook printers f) ACs(Split unit/window unit) g) Water Cooler h) Any other equipment (submit a separate sheet if required) Are there separate earthing connection for raw current, UPS and generators and Status of earthings are in good condition /adequate rating.(Yes/No) (If No then give suggestion) Total no. of UPS in the branch with capacity Whether appropriate UPS capacity/load for branch/offices premises(Yes/No) (If NO give suggestion) Status of UPS panel wiring. (Good/medium/poor) Any major fault found in service report of UPS and battery in last six month (Yes/No)(If Yes then give full details with suggestion) Is the UPS room kept clean & stationery/furniture etc not stored inside? (Yes/No) (If No give suggestion) Whether appropriate and proper ventilation/exhaust options available at the place where the batteries are stacked(Yes/No)(If No then give suggestion) Whether UPS and ACs are in under AMC (Yes/No) (If No then give suggestion) Any major faults found in AMC service report of UPS and ACs(last six months) (Yes/No) (If Yes give full details with observations)

18 19

20 21

22 23

24 25

26

Total no. of ACs with capacity Whether power supply for each AC unit is appropriate and proper connection with main power source.(Yes/No) (If no then give suggestion) Any other fire risk through electric in the premises(Yes/No) (If yes then give details) Overall fire risk rating through electrical wiring, switches, MCB etc. (High/Medium/Low)(Risk rating format attach in para 1.3) Any other Remarks regarding electric audit of the branch/Office ( may include addition sheet if require)

1.3 Risk Rating format of Branch/office on basis of electricitySr Any penalty Any overload in paid by branch branch/office(Y in last six es/No) month(Yes/No) Inadequate rating of MCB/Master switch(Yes/No) Any fire risk inUPS and battery room(Yes/No) Poor wiring in branch(Yes/ No)

Low RiskMedium RiskHigh Risk-

Less than two (02) (In Yes) Between two (02) to four (04) (In Yes) More than four (04) (In Yes)

Note: Electrical auditor/inspector may submit additional sheet on his/her observations.

Electrical auditor/inspector may submit the technical details / specifications for proper wiring, Switches, MCB or other details for the branch/office on his observations or audit report.

To be submitted in an envelope marked Cover No 2 Financial Bid


ANNEXURE- III FINANCIAL BID FOR ELECTRIC AUDIT Sr. Branch located (Within 50 Branch Located Km from the zonal (between 50 km to 200 office)(Unit rate) km from zonal office)(Unit rate) Branch located ( more than 200 km from the zonal office)(Unit rate)

Signature (Seal)

Note :- 1. The rates for electric audit should be inclusive travelling charges and
other expenses. The bank will not pay any additional amount excluding service tax to the aforesaid job.

Cover No 1 And Cover No 2 (i.e. Technical Bid and Financial Bid) should be put in a third envelope marked TENDER ELECTRICAL AUDIT