Equipment:
DETAILED ENGINEERING
Order: VEC001101
DATE
DOCUMENT
ORDER
Nov-2012 INDEX
VEC001101
CUSTOMER
CONSISTENTS WITH OUR CONTINUAL PRODUCT IMPROVEMENT POLICY, GUASCOR POWER RESERVES THE RIGHT TO CHANGE ANY SPECIFICATION WITHOUT PRIOR NOTICE.
DATE
DOCUMENT
ORDER
Nov-2012 INDEX
VEC001101
CUSTOMER
MEASUREMENT TABLES
From
Transformer 1 Transformer 2 Transformer 3 Transformer 4 Transformer 5 Transformer 6 Transformer 7 Transformer 8 Transformer 9 Transformer 10 Transformer 11 Transformer 12 Transformer 13 Transformer 14 Transformer Cell Room (C15) Transformer Cell Room (C16) Transformer Cell Room (C15)
To
Transformer Cell Room PLC (C-1) Transformer Cell Room PLC (C-2) Transformer Cell Room PLC (C-3) Transformer Cell Room PLC (C-4) Transformer Cell Room PLC (C-5) Transformer Cell Room PLC (C-6) Transformer Cell Room PLC (C-7) Transformer Cell Room PLC (C-8) Transformer Cell Room PLC (C-9) Transformer Cell Room PLC (C-10) Transformer Cell Room PLC (C-11) Transformer Cell Room PLC (C-12) Transformer Cell Room PLC (C-13) Transformer Cell Room PLC (C-14) Incoming Switchgear Stall (C-18) Incoming Switchgear Stall (C-19) Incoming Switchgear Stall (C-18)
Cable
RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 10x1,5 mm RV-K 2x1,5 mm RV-K 4x4 mm RV-K 4x4 mm RV-K 8x1,5 mm
Description
Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarms Trafo DGPT2 relay. Alarm Aux Trafo temperature. Signs of CTs differential protection Signs of CTs differential protection Book exchange signals
Amount
52 43 34 32 41 50 52 43 34 32 41 50 57 57 125 125 125
CONSISTENTS WITH OUR CONTINUAL PRODUCT IMPROVEMENT POLICY, GUASCOR POWER RESERVES THE RIGHT TO CHANGE ANY SPECIFICATION WITHOUT PRIOR NOTICE.
DATE
DOCUMENT
ORDER
Nov-2012 INDEX
VEC001101
CUSTOMER
From
Transformer Cell Room (C16) Transformer 15 Transformer 15 Transformer 16 Transformer 16 T15 cell resistances Trafo T16 cell resistances Trafo T15 cell resistances Trafo T16 cell resistances Trafo
To
Incoming Switchgear Stall (C-19) Incoming Switchgear Stall PLC Incoming Switchgear Stall PLC Incoming Switchgear Stall PLC Incoming Switchgear Stall PLC Incoming Switchgear Stall (C-18) Incoming Switchgear Stall (C-19) Incoming Switchgear Stall PLC Incoming Switchgear Stall PLC
Cable
RV-K 8x1,5 mm RV-K 4x6 mm (3F+N) RV-K 3x(16x2,5 mm) RV-K 4x6 mm (3F+N) RV-K 3x(16x2,5 mm) RV-K 2x4 mm RV-K 2x4 mm RV-K 8x1,5 mm RV-K 8x1,5 mm
Description
Book exchange signals Food 400Vac Tap Alarm and Controller Food 400Vac Tap Alarm and Controller TI Signal Ground TI Signal Ground State disconnector State disconnector
Amount
125 57 57 49 49 12 12 12 12
CONSISTENTS WITH OUR CONTINUAL PRODUCT IMPROVEMENT POLICY, GUASCOR POWER RESERVES THE RIGHT TO CHANGE ANY SPECIFICATION WITHOUT PRIOR NOTICE.