Sie sind auf Seite 1von 148

Catalog | August 2013

Kabeldon cable accessories 1 420 kV Product catalog 2013

Table of contents

Introduction

1 2 3 4 5 6 7 8 9

Cable accessories 1 kV

Cable accessories for XLPE-insulated cables 7.242 kV

Cable accessories 1252 kV, PILC cables

Other accessories for 1242 kV

Cable accessories for XLPE-insulated cables 52420 kV

Universal clamps

List of contents Alphabetical order

List of contents by category

ABB Catalog 2013 | Kabeldon cable accessories 1420 kV |

1/1 | Kabeldon cable accessories 1420 kV | Introduction

Table of contents Introduction

1
Introduction Introduction Fundamental technologies Reasons for choosing Kabeldon cable accessories Standards Manufacturing and testing 1/3 1/4 1/5 1/7 1/9

Introduction | Kabeldon cable accessories 1420 kV |

1/2

Introduction

Our factory is situated in Alingss, Sweden. The production is automated and meets stringent quality and environmental requirements.

We work to create safe electrical distribution via power cable networks. To achieve this, we develop, manufacture and market a broad range of cable accessories, switching devices and enclosures. Our main groups of customers are power supply companies, network companies, industrial companies and OEMs. Our primary areas of expertise are electrical connections in cable systems and control of electrical fields. Our own testing plant is an important aid to product development. Catalog The entire product range is presented in three main parts including product facts and ordering information in tabular form. Cable accessories 1 kV Cable accessories 1242 kV Cable accessories 52420 kV An alphabetical list of contents and a list of contents by product category can be found in the end of this catalogue. The product catalogue can also be downloaded from our website. A separate product catalog for Kabeldon low voltage switchgear system is available on request. We reserve the right to alter the design and range of our products without prior notice.

Our business idea We provide companies that work with electric power with solutions which enable them to joint and connect cables easily and safely, and distribute electricity. Quality and the environment are among our top-priorities. They are important and self-evident parts of the strategic plan. We work continuously to improve our processes. Important foundations for this work are: ISO 9001 quality standard ISO 14001 environmental standard.

ABB AB Kabeldon Box 531, SE-441 15 Alingss, Sweden Tel: +46 322 770 00 e-mail: info.sedon@se.abb.com www.abb.com/cableaccessories

1/3 | Kabeldon cable accessories 1420 kV | Introduction

Fundamental technologies

1
We work on the basis of four fundamental technologies within which we have accumulated substantial expertise over many years. 1. Electrical connections The safe and secure transfer of electric current between cable conductors, or between a cable conductor and a device, requires an electrical connection of good quality. We test and develop various methods, but in most cases we use bolt technology, that gives us the possibility of offering complete solutions in line with our philosophy of easy and safe installation. 2. Controlling electrical fields At high voltages the electrical fields must be controlled so that the strength of the insulation or the surrounding material is not put at risk. Depending on the voltage level, we work with different methods, e.g. geometrical, refractive or resistive field control. Geometrical field control is achieved with premolded stress relief cones and cable joint bodies. Resistive and refractive field control are achieved with special field controlling materials integrated into premolded cable terminations and cable joints. 3. Development of creepage current resistant materials Outdoors, cable accessories are exposed to major stresses, e.g. UV radiation from the sun and creepage currents caused by precipitation and pollution. Cable accessories are installed everywhere on the face of the planet: in humid tropical environments, in extreme cold or in the swirling salt mist of coastal regions. We develop materials and designs for outdoor use that are only minimally affected by external factors. Practical endurance tests are an important part of our development work. In addition to Weather-O-Meter, salt-mist-chamber tests and other destructive long-term tests, the products are tested under outdoor weather conditions. 4. Design of low voltage networks Electrical distribution in power cable networks calls for safe and rugged products to connect cables and to withstand external factors such as humidity, vibration, etc., for a long time without causing malfunctions. Lengthy experience of manufacturing switching devices and hot-dip galvanized enclosures, together with good customer relations, means that we can quickly adapt product development to suit the needs of the market.

1.

3.

2.

4.

Introduction | Kabeldon cable accessories 1420 kV |

1/4

Reasons for choosing Kabeldon cable accessories

1
A power cable network must be capable of supplying electric power without interruption. If a failure does occur, it is usually the junction points in the network that are at fault, rarely the cable. So it pays to choose cable accessories with care. Unique, long experience Long experience brings great expertise. We have been manufacturing cable accessories for paper-insulated cables for about 100 years. When XLPE-insulated cables began to be used more than 50 years ago, we were involved from the outset. Since then we have always been in the forefront of developments. Leading research and development Our core competence is our expertise in electrical onnections in power cable systems. Successful product development requires proper resources. We have an advanced chemistry laboratory, a profound expertise in the field of polymers and well-equipped high voltage and high-current laboratories. Better economy Kabeldon cable accessories provide greater safety. This means major savings in the long term, as well as lower costs from simplified routines for purchase, delivery and storage.

Manufacturing outdoor cable termination for paper-insulated cables in 1962.

1/5 | Kabeldon cable accessories 1420 kV | Introduction

1
Professional training The technology of cables and their installation is constantly developing. We offer a broad range of courses in cable technology and cable accessories. Our instructors also take part in our development projects, so you can be sure that they have access to the latest technology. We arrange training programmes and practical exercises in the assembly of cable accessories up to 420 kV. All course participants will receive a diploma or a training certificate after passing a theoretical and practical test. If you would like to know more about the courses, please contact your ABB representative or our training department directly.

Introduction | Kabeldon cable accessories 1420 kV |

1/6

Standards

1
Definition of voltages Cables and cable accessories are classified according to the voltages at which they operate. A rapid survey at standards all over the world shows that the designations are a little different. However, IEC designations gives a clear picture of used vocabulary. The voltages normally used in this context are: U0 = the rated r.m.s.(root mean square) power-frequency voltage between each conductor and screen or sheath for which cables and accessories are designed. U = the rated r.m.s power-frequency voltage between two different conductors for which the cables and accessories are designed. Um = the maximum r.m.s power-frequency voltage between two different conductors for which the cables and accessories are designed. It is the highest voltage that can be sustained under normal operating conditions at any time and at any point in a system. It excludes temporary voltage variations due to fault conditions and the sudden disconnection of large loads. Standards and type testing Electrical components must meet numerous requirements in areas such as functional safety, technical performance, personal safety and so on. For cable accessories, compliance with the quality requirements is checked by type and routine testing. We perform these tests to various standards, both international and national. These are the standards on which our tests are usually based: IEC (International Electrotechnical Commission) An international standard. EN (European Norm) HD (Harmonization Document) These standards were developed by CENELEC for the European countries. The aim is to use the same standards throughout Europe to eliminate obstacles to trade. In most cases, these standards harmonize with IEC standards. Each European country publishes the standard as its own, and there may be some national deviations and special requirements. IEEE (The Institute of Electrical and Electronics Engineers) This standard is mainly used in the USA. Some customers require special tests that are not included in the usual standards. We are usually able to meet their requirements.

Tests in the high voltage laboratory. 1/7 | Kabeldon cable accessories 1420 kV | Introduction

Standards

1
Voltage range Um 1.2 kV In this voltage range, the function of cable accessories is to provide mechanical protection and insulation. There is no need for controlling the electrical field. In the past, there was no international standard, only national standards. CENELEC therefore produced an international standard, HD 623 S1, which is equivalent to Swedish standard, SS 424 14 44. When the CENELEC standard is adopted in a country, it can be supplemented with one or more national options, for example requirements for impact resistance at low ambient temperature. Voltage range Um 7.2-42 kV IEC: Current standards are IEC 61442, which covers test methods, and IEC 60502-4, which sets out the testing requirements. IEC contains Um 36 kV. CENELEC: Current standards are EN 61442 which covers test methods and is identical to IEC 61442. HD 629.1 S2, which sets out the testing requirements. The main difference between IEC and CENELEC is that CENELEC stipulates a longer period of temperature cycling under voltage. HD 629.2 S1 applies to accessories for paper-insulated cables and transition joints. A test conducted in accordance with CENELEC also satisfies the IEC requirements. To include the less common voltages which occur in certain European countries, CENELEC has included more voltage classes than IEC. In addition, CENELEC runs up to U m42 kV. IEEE: The currently applicable standards are Std. 48 for terminations covering insulation classes 2.5-765 kV, and Std. 404 for joints rated at 2.5-500 kV. The test voltage for joints is generally lower than for equivalent terminations. The voltage classes in IEEE are not identical with those in IEC. Some of the definitions also differ slightly between IEEE and IEC. This can make direct comparisons difficult. Voltage range Um 52420 kV IEC standard 60840 covers cable systems with voltages above 36 kV up to 170 kV. The third edition of the standard now also treats routine testing of cable accessories. IEC standard 62067 covers cable systems with voltages above 170 kV up to 550 kV. The standard also states methods and requirements for the routine testing of cable accessories. Both IEC 60840 and IEC 62067 deal with testing of outer protection for buried joints and screen separation kits. These tests are to qualify the electrical performance of the outer protection with special emphasis on watertightness. IEC voltage classes
U0 26 36 64 76 87 127 160 190 220 U 4547 6069 110115 132138 150161 220230 275287 330345 380400 Um 52 72.5 123 145 170 245 300 362 420

CENELEC voltage classes


U0 3.6 3.8 6 6.35 8.7 12 12.7 18 19 20.8 U 6 6.6 10 11 15 20 22 30 33 36 Um 7.2 7.2 12 12 17.5 24 24 36 36 42

We supply cable accessories for various types of cables.

Introduction | Kabeldon cable accessories 1420 kV |

1/8

Manufacturing and testing

A snapshot of a cable termination manufacture.

Research and development are the basis for the manufacturing of our products.

Manufacturing of premolded connectors. The different layers are vulcanized together.

The premolded cable joints are routine tested after manufacturing.

The three layers of the joint are vulcanized together in a unique manufacturing process. 1/9 | Kabeldon cable accessories 1420 kV | Introduction

Electrical testing of cable termination for 420 kV at our high voltage laboratory.

We test and develop electrical connections with reliable bolt connector technology.

Testing Kabeldon cable termination APECB 245 P and cable joint JS-A 245 in an independent laboratory.

Shortcircuit test, HDC-A.

Cycling rigging for testing electrical connections.

Testing Kabeldon dry cable termination TD 145 in an independent laboratory.

Introduction | Kabeldon cable accessories 1420 kV |

1/10

2/1 | Kabeldon cable accessories 1420 kV | Cable accessories < 1 kV

Table of contents Cable accessories < 1 kV

Introduction Introduction Cable accessories 1 kV Cable joint with cast resin for plastic and paper-insulated cables, and control cables, SMARTA Cable joint, branch for plastic-insulated cables, SAGA 11 Y Cable joint, heat-shrink for plastic-insulated cables, SMKC Cable joint, tape for plastic-insulated cables, SMILA and SMULA Protective hood for plastic-insulated cables, LPH Protective hood for plastic-insulated cables, LXAC Connection protection for plastic-insulated cables, KAL Cable connection , prefabricated, AK-ADAS 2/4 2/5 2/6 2/7 2/8 2/9 2/10 2/11 2/3

Cable accessories < 1 kV | Kabeldon cable accessories 1420 kV |

2/2

Introduction Cable accessories 1 kV

The most important tasks of the cable accessories are to create a safe electrical connection, insulation and provide mechanical protection. The product range includes accessories designed on different principles with different properties. Accessories which utilize tape technology are simple to use, flexible and unaffected by the dimensions of the cable. Cable accessories which utilize heat-shrink technology offer a simple alternative.

Cast resin products are the obvious choice in slightly more challenging environments.The robust joint is able to cope with a water depth of 10 metres, and can be used for both power and control cables.

Cast resin joint type SMARTA.

Protective hood type LPH.

Cable connection AK-ADAS. Tape joint type SMILA / SMULA.

Cast resin branch joint type SAGA. Protective hood type LXAC.

Connection protection type KAL.

Heat-shrink joint SMKC.

2/3 | Kabeldon cable accessories 1420 kV | Cable accessories < 1 kV

Cable joint with cast resin for plastic and paper-insulated cables, and control cables SMARTA
Use For jointing 1 kV plastic and paper-insulated 35 core cables as communication cables and the transition between plastic and paper-insulated cables. Standards Meets the requirements of: SS 424 14 44 Edition 1 EBR KJ 24:89 Design The joint consists of a transparent casting mold with flexible sealing rings between the casting mold and the cable. Compounding cast resin and hardener are mixed in a sealed bag. After hardening the joint becomes resistant. Please note, the lower the temperature is, the longer the hardening time will be. Hardening time is reduced if cast resin is stored warm until use. SMARTA should not be installed if temperature is below -10 C. When jointing paper-insulated cable, and at the transition between paper and plastic cables, accessory kit PPC must be used. Note that, when jointing plastic-insulated to paperinsulated cables, connectors with a partition must be used. The joint is also excellent to use when jointing cables with an integrated tube for opto fiber, which must be jointed without heating. The material for jointing the opto tube is not included. Can be used in down to 10 metres water depth. To be ordered separately Connectors PPC (see below)
Designation Conductor cross section Cu mm SMARTA SMARTA SMARTA SMARTA SMARTA 10-5 11-5 12 13 14 2.510 616 2570 95150 185240 2550 70150 185240 Al Control cable with without mm 527 1530 2550 3065 3570 Cable Casting mold Length 240 340 540 660 840 Diameter mm 35 40 72 96 105 kg/item 0.8 1.2 3.6 7.6 10.5 Weight

Hardening time hours

Outdoor temperature Compounding cast resin; hardening time in relation to temperature

max number of cores diameter individual screen 14 27 27 39 91

To be ordered separately
Accessory kit PPC 11 PPC 12 PPC 13 PPC 14 Used for SMARTA 10-5 / SMARTA 115 SMARTA 12 SMARTA 13 SMARTA 14 Weight kg/item 0.2 0.3 0.4 0.5

Cable accessories < 1 kV | Kabeldon cable accessories 1420 kV |

2/4

Cable joint, branch for plastic-insulated cables SAGA 11 Y

Use Branching of 1 kV plastic-insulated 34 core cables.

2
Standards Meets the requirements of: SS 424 14 44 Edition 1 EBR KJ 24:89 Design The joint consists of a transparent casting mold with flexible sealing rings between the casting mold and the cable. Compounding cast resin and hardener are mixed in a sealed bag. After hardening the joint becomes resistant. Hardening time is reduced if cast resin is stored warm until use.

Please note, the lower the temperature is, the longer the hardening time will be. SAGA 11 Y should not to be installed if the temperature is below -10 C.
L

Branching takes place with the help of clamps which penetrate the insulation on the main cable. The clamps, which are included in the kit, are tightened with a torque wrench. Can be used in down to 10 metres water depth.
Hardening time hours

Outdoor temperature Compounding cast resin; hardening time in relation to temperature

Designation

Conductor cross section Main cable Branch cable mm 1050

Diameter Main cable 1530 Branch cable mm 525

Dimensions L mm 500 96

Weight kg/item 4.5

SAGA 11 Y

1650

2/5 | Kabeldon cable accessories 1420 kV | Cable accessories < 1 kV

Cable joint, heat-shrink for plastic-insulated cables SMKC

Use For jointing 1 kV plastic-insulated cables with 35 cores, with or without screen. Standards Meets the requirements of: SS 424 14 44 Edition 1 EBR KJ 24:89 Design SMKC 11-5 contains one outer and five inner sleeves. SMKC 12, SMKC 13 and SMKC 14 contain one outer and four inner sleeves. The sleeves are made of cross-linked polyethylene, coated internally with a hot-melt adhesive and are installed with heat. To be ordered separately Connectors

Designation

Conductor cross section plastic cable

Outer sleeve before/after heat-shrinkage

Weight

Al SMKC 11-5 SMKC 12 SMKC 13 SMKC 14 2550 70150 185240

Cu mm 2.516 2570 95150 185240

Al/Cu 50/25 150/7095 240/120150

Length mm 380 550 790 950

max/min kg/item 34/14 66/20 83/26 110/40 0.2 0.4 0.5 0.9

Cable accessories < 1 kV | Kabeldon cable accessories 1420 kV |

2/6

Cable joint, tape for plastic-insulated cables SMILA and SMULA

Use For jointing 1 kV plastic-insulated cables with 35 cores, with or without screen. SMILA is used for jointing cables with screen. Otherwise SMULA is used. Standards Meets the requirements of: SS 424 14 44 Edition 1 EBR KJ 24:89 Design The kit contains insulating vulcanizing tape and electrical tape. SMILA also includes a copper net. Insulating vulcanizing tape is used for insulation of the connectors. The stripped cable sheaths and electrical tape are used as outer protection. The cable joints are packed in kits. Two SMILA 12 or SMULA 12 kits are used to joint 70150 mm cables, and three kits are used for 185240 mm cables. To be ordered separately Connectors

Designation

Conductor cross section Al mm Cu 2.516 2570 95150 185240 2.516 2570 95150 185240

Cable joint Length mm 420 570 770 920 420 570 770 920

Weight kg/item 0.2 0.3 0.6 0.9 0.1 0.3 0.6 0.9

SMILA 11 SMILA 12 SMILA 12 (two) SMILA 12 (three) SMULA 11 SMULA 12 SMULA 12 (two) SMULA 12 (three)

2550 70150 185240 2550 70150 185240

For larger cable cross sections, use SMILA 12 as below

For larger cable cross sections, use SMULA 12 as below

2/7 | Kabeldon cable accessories 1420 kV | Cable accessories < 1 kV

Protective hood for plastic-insulated cables LPH

Use Termination outdoors for 1 kV plastic-insulated underground cables with 35 cores, 2.5-95 mm. Standards Meets the requirements of: SEN 24 14 34 Design The cable termination consists of a hood made of weather-proof and oil-resistant rubber. The cable cores are bent downwards and fixed with tape before the hood is pushed on. Cable cores can be protected against UVradiation by using IS insulating hose.

Designation 3-core LPH 2532 LPH 4052 LPH 6070 LPH 70 16 50 95

Conductor cross section 4-core mm 10 35 70 95 10 16 5-core

Internal diameter mm 30 49 67 68

Internal height mm 83 137 176 175

Weight kg/item 0.1 0.1 0.3 0.3

To be ordered separately

IS
Insulating hose for plastic cables, overhead cables or for connection to aerial bundled cables. Meets the requirements of SEN 24 21 11 and is UV- and cold-resistant.

Designation IS 16 IS 50 IS 95

Conductor cross section mm 2.516 2550 7095

Thickness mm 0.7 1.0 1.2

Length m/roll 25 25 25

Weight kg/roll 0.7 1.5 2.3

Cable accessories < 1 kV | Kabeldon cable accessories 1420 kV |

2/8

Protective hood for plastic-insulated cables LXAC

Use Outdoor termination for 1 kV plastic-insulated underground cables, 24 cores 2.5-35 mm. Standards Meets the requirements of: SEN 24 14 34 Design The cable termination consists of a bushing and hood made from impact-resistant black polyethylene. The cable cores are bent downwards and pushed into grooves in the bushing before the hood is pushed on. Cable cores can be protected against UV-radiation by using IS insulating hose.

Designation

Conductor cross section polymeric cable 3- and 4-core mm

Max cable diameter mm 27 31

External diameter mm 60 75

Height mm 100 125

Weight kg/item 0.1 0.1

LXAC 116 LXAC 135

16 35

Tillbehr, bestlls separat

IS
Insulating hose for plastic cables, overhead cables or for connection to aerial bundled cables. Meets the requirements of SEN 24 21 11 and is UV- and cold-resistant.

Designation IS 16 IS 50

Conductor cross section mm 2.516 2550

Thickness mm 0.7 1.0

Length m/roll 25 25

Weight kg/roll 0.7 1.5

2/9 | Kabeldon cable accessories 1420 kV | Cable accessories < 1 kV

Connection protection for plastic-insulated cables KAL

Use Enclosed connection protection for transformer bushings 1.2 kV. Standards Electrical breakdown strength > 40 kV. Design KAL is made from UV-resistant PVC latex and consists of an inner yellow and an outer black layer. These layers provide double insulation, at the same time as the inner yellow layer functions as a warning signal in the event of wear or damage to the protection. Each kit includes three hoods.

A B

Designation

Max cable diameter mm

Max bushing diameter A mm 35 50 50 75 B

Weight kg/kit 0.70 1.25

KAL 11 KAL 12

15 20

Cable accessories < 1 kV | Kabeldon cable accessories 1420 kV |

2/10

Cable connection, prefabricated AK-ADAS

Use For the extension of Al cable, for example in conjunction with connection in cable distribution cabinets, service distribution boards and switchgears. Dimensioned in accordance with the cable loading and short-circuit data. Standards Meets the requirements of: SEN 24 50 10 Edition 1 SEN 24 50 12 Edition 1 Design Flexible XLPE-insulated Cu conductor compressed onto a prefabricated Al/Cu cable connection. The aluminium part is designed for crimping with the Elpress system. The length of all the connectors are 700 mm.

Designation

Fits aluminium conductor cross section mm

Conductor cross section of connector mm 25 35 50 70 70 120 120

Weight kg/kit 0.2 0.3 0.5 0.5 0.6 0.9 1.0

AK-ADAS 5025-7 AK-ADAS 7035-7 AK-ADAS 9550-7 AK-ADAS 12070-7 AK-ADAS 15070-7 AK-ADAS 185120-7 AK-ADAS 240120-7

50 70 95 120 150 185 240

2/11 | Kabeldon cable accessories 1420 kV | Cable accessories < 1 kV

Cable accessories < 1 kV | Kabeldon cable accessories 1420 kV |

2/12

3/1 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Table of contents Cable accessories for XLPE- and EPR-insulated cables 1242 kV

Introduction Cable accessories 1242 kV 3/3

Cable terminations Dimensional drawings, SOT Premolded cable termination, indoor, SOT 7.2 kV Premolded cable termination, complete kits, SOT SCL 1236 kV Premolded cable termination, SOT 1236 kV Cable termination for cables with Cu-tape screen, SOT 1236 kV Cable termination, recommended to be used in applications were significant harmonics may occur, indoors, APIT 1236 kV Cable termination, recommended to be used in applications were significant harmonics may occur, outdoors, APSEA 1236 kV 3/12 3/11 3/4 3/5 3/6 3/7 3/8

Cable connectors and shrouded terminations Screened separable cable connectors, CSE-A 1224 kV, 250 A Screened separable cable connectors, CSE-A 1242 kV, 400 A Screened separable cable connectors, CSE-A 1242 kV, 630 A Screened separable connectors for cables with Cu-tape screen, CSE-A 1236 kV, 630 A Parallel connectors, CSEP-A 1242 kV, 630 A Parallel connectors for cables with Cu-tape screen, CSEP-A 1224 kV, 630 A Surge arresters for 630 A connectors, CSAP-A, 1224 kV, 630 A Shrouded termination, TB-A 12 kV, 630 A Shrouded termination, KAP 630, 1224 kV, 630 A Shrouded termination, KAP 300 U, 1224 kV, 300 A 3/23 3/25 3/26 3/27 3/29 3/20 3/22 3/14 3/17 3/19

Cable joints Cable joint with cold shrink outer jacket, SOJ CS, SOJ CSS 1224 kV Cable joint for radially watertightened cable, SOJ CSWS, SOJ RWI, SOJ RWIT 1224 kV Cable joint with or without outer jacket, SOJ SL, SOJ R 1224 kV Cable joint with heat-shrink outer jacket, SOJ HSTS 1236 kV Cable joint, for cables with Cu-tape screen, SOJ EA 1224 kV Tape cable joint, SMXB 1236 kV 3/31 3/32 3/33 3/35 3/39 3/30

Cable cabinets Cable cabinet, 1224 kV, 250 A Cable cabinet, 1236 kV, 630 A 3/41 3/43

Accessories Screen separation kit for 3-core cables, PSSK, PSSK L, PSSK E Branch seal kit for 3-core cable terminations, TSH, SSH Earthing kit for cable terminations, JSA 46, JXT 13 Screen connection for cable joints, JSA 1016 Armouring kit for cable joints, ARM Cable connection, cverhead line clamps, FK, FKFB Cable connection, cable lugs, SCL-B Cable connection, cable connectors, SH-SKRM Accessories, bird protection, HU, HUF, HUS 3/45 3/46 3/47 3/48 3/49 3/50 3/51 3/51 3/52

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/2

Introduction Cable accessories for XLPE- and EPR-insulated cables 1242 kV

Kabeldon cable accessories for 1242 kV are characterized by simple solutions with a reliable function. Long experience and continuous product development enable us to offer products that meet future requirements for reliable and dependable systems.

The use of flexible materials enables the cable accessory to follow the variations in the cable under load, thus ensuring an active pressure for a reliable power transmission. Manufacturing the products from soft rubber also means that fewer sizes covers different cable dimensions. All of this, in combination with the bolt technology that we use in our cable connectors and cable lugs, gives a reliable and dependable system. More than one million premolded cable joints, cable terminations and cable connectors have already been installed by customers in electricity distribution networks all over the world. Our cable terminations and screened separable cable connectors are also purchased by customers who manufacture switchgears and other installations. In addition to the products presented in this catalogue, we offer especially adapted products and solutions for different markets and cables and a range of cable preparation tools. Please do not hesitate to contact us if you have any other needs or queries.

3
At the time when XLPE-insulated cable was introduced in the beginning of the 1960s, we already appreciated the importance of the cable accessories having a constant, active pressure over the cable, in this way following the physical changes in the cable in service. The solution at the time was to use tapes with different properties. Our patented field-control material and the first premolded products were introduced in the 1970s. The technology has since been a guiding force for our product development. Our current range includes cable joints, cable terminations and screened separable cable connectors in line with this concept. The fact that the products are premolded means that they are manufactured in a single piece including important functions such as electrical field-control, insulation and sealing.

Cable accessories with four important functions: control of electrical fields, control of creepage currents, moisture barriers and mechanical protection.

3/3 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Dimensional drawings Installation of cable termination

Minimum air gap


Max voltage kV 10 12 24 36 Phase to earth A 90 120 220 320 Indoor Phase to phase B 90 120 250 370 Phase to phase C 10 10 30 50 Outdoor Phase to earth A 130 160 270 380 Phase to phase B 130 160 270 380

Minimum air gap between cores* in parallel


10 kV C 10 mm 12 kV 10 mm 24 kV 30 mm 36 kV 50 mm

* The cable terminations must be placed in the same height.

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/4

Premolded cable termination, indoors SOT 7.2 kV

Use Premolded cable termination for XLPE- and EPR-insulated cables 1- or 3-core with Al or Cu conductor for 6.6/7.2 kV, indoors. It can also be installed in an indoor humid environment*.

3
Standards Meets the requirements of: CENELEC, HD 629.1 S1 Design Premolded cable termination made of silicone rubber with integrated field control. The length of the termination is approximate 145 mm which also makes it suitable for installations in narrow spaces. The termination is supplied in kits for 3 single-core cables. Note: Cable lugs are to be ordered separately. Branch seal TSH for 3-core cable is to be ordered separately.

145

Always select products by Insulation diameter.


* For the best watertightness in an indoor humid environment, order branch seal kit TSH. See page 3/46.

Insulation diameter mm 3-core / three 1-core 10.515 12.925.8 21.434.9

Conductor cross section mm 1035 50185 185500

Designation

Conductor cross section mm

Weight kg/kit 0.2 0.2 0.2

SOT 1013 SOT 102-3 SOT 103-3

1035 50185 185500

3/5 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Min

200

Premolded cable termination, indoors and outdoors, complete SOT SCL 1236 kV

Use Premolded cable termination for XLPE- and EPR-insulated 1- or 3-core cable with Al- or Cu- conductor for 1236 kV. The indoor termination can also be installed in a humid indoor environment*.

3
Standard Fulfills requirements of: SS 424 14 45 edition 1 IEEE 48 1996 CENELEC HD 629.1 Design Premolded cable termination made of silicone rubber with integrated field control and top sealing. The outdoor type is provided with permanent sheds for extended creepage distance. The cable termination is supplied in kits for 1- or 3-core cables. The kits include: Bi-metalic shear-off cable lugs SCL-B for Al- and Cuconductor. The cable lug has bolts which breaks off once the correct torque is reached. Branch seal and protective heat-shrink hoses in kits for outdoor, 3-core cables.
* For the best watertightness in an indoor humid environment, order branch seal kit TSH. See page 3/46.

SOT 1- and 3-core outdoor.

SOT 1- and 3-core indoor.

Always select products by Insulation diameter.


weight Designation weight kg/kit 1-core indoor SOT 241 A SCL2 SOT 241 SCL3 SOT 242 SCL5 SOT 242 SCL6 SOT 242 B SCL6 1-core outdoor SOT 243 A SCL2 SOT 243 SCL3 SOT 244 SCL5 SOT 245 SCL6 0.30 0.45 0.60 1.15 1.20 0.40 0.55 0.70 1.40

Insulation diameter mm 1115 1526 2439 2439 2439 3854 1115 1524 2233 3140 3140 2639 1524 2233 3140 3140 3854 2639 3854

Conductor cross section 12 kV 24 kV mm 1035 50150 185300 400 500 630 1035 50150 185300 400 500630 1035 50150 185300 400 500630 1016 2595 120300 400 500 500630 1016 2595 120300 400 500630 1016 2595 120300 400 500630 70300 70300 400630 36 kV

Designation

kg/kit 3-core / 3 x 1-core indoor SOT 241 A-3 SCL2 0.90 SOT 2413 SCL3 1.35 SOT 242-3 SCL5 1.80 SOT 242-3 SCL5B 3.30 SOT 242-3 SCL6 3.40 SOT 242 B-3 SCL6 3.60 3-core outdoor SOT 243 A-3 SCL2 2.20 SOT 243-3 SCL3 2.55 SOT 244-3 SCL5 3.05 SOT 245-3 SCL5B 5,10 SOT 245-3 SCL6 5.20 3-core indoor/outdoor SOT 3613 SCL5 3.10 3 x 1-core outdoor SOT 243 A-31 SCL2 1.10 SOT 243-31 SCL3 1.65 SOT 244-31 SCL5 2.15 SOT 244-31 SCL5B 4,10 SOT 245-31 SCL6 4.20 3 x 1-core indoor/outdoor SOT 36131 SCL5 2.45 SOT 362-31 SCL6 4.30

1-core indoor/outdoor SOT 361 SCL5 0.82 SOT 362 SCL6 1.45
3/6

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

Premolded cable termination, indoors and outdoors SOT 1236 kV

Use Premolded cable termination for XLPE- and EPR-insulated cables 1- or 3-core with Al or Cu conductors for 1236 kV. The indoor termination can also be installed in a humid indoor environment*.

3
Standard Meets the requirements of: CENELEC, HD 629.1 S1 IEEE 48 1996 Design Premolded cable termination made of silicone rubber with integrated field control and top sealing. The outdoor type is provided with permanent sheds for extended creepage distance. The termination is supplied in kits for 1- or 3-core cables. 3-phase kits for outdoor use include branch seal and protective heat-shrink hoses.
* For the best watertightness in an indoor humid environment, order branch seal kit TSH. See page 3/46.

SOT 1- and 3-core outdoor.

SOT 1- and 3-core indoor.

Note: Cable lugs are to be ordered separately. Always select products by Insulation diameter.

Insulation diameter mm 1115 1526 1526 2439 1115 1526 2439 3854 1115 1524 2233 3140

Conductor cross section 12 kV 24 kV mm 1035 5095 120185 185400 1035 50185 185500 630** 1035 50150 150300 400500 1016 2550 70120 150400 1016 25120 150400 500630** 1016 2570 95240 300400 2570 95240 300400 500630* 70300 400630* 36 kV

Designation

Weight

Designation

Weight kg/kit

1524 2233 3140 3854 2639 3854

50150 150300 400500 500630**

kg/kit Indoor termination incl. branch seal for 3-core SOT 241A-3C 0.9 SOT 2413C 0.9 SOT 2413D 1.3 SOT 242-3D 1.4 Indoor termination 3-core / 3 x 1-core SOT 241 A-3 0.60 SOT 2413 0.60 SOT 242-3 0.70 SOT 242 B-3 0.90 Outdoor termination incl. branch seal for 3-core SOT 243 A-3 1.90 SOT 243-3 1.80 SOT 244-3 2.00 SOT 245-3 2.50 Indoor/outdoor termination 3-core SOT 3613 Outdoor termination 3 x 1-core SOT 243-31 0.80 SOT 244-31 0.90 SOT 245-31 1.11 SOT 246-31 1.50 Indoor/outdoor termination 3 x 1-core SOT 36131 1.40 SOT 362-31 1.60

Indoor termination 1-phase kit SOT 241 A 0.20 SOT 241 0.19 SOT 242 0.23 SOT 242 B 0.30 Outdoor termination 1-phase kit SOT 243 A 0.31 Indoor/outdoor termination 1-phase kit Outdoor termination 1-phase kit SOT 243 0.27 SOT 244 0.30 SOT 245 0.38 SOT 246 0.51 Indoor/outdoor termination 1-phase kit SOT 361 0.42 SOT 362 0.52

* Can be mounted on cables with 800 and 1000 mm by using silicone rubber tape IA 2342 (1 per kit) as top seal, see page 5/3.

3/7 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Premolded cable termination for cables with Cu-tape screen SOT 7.236 kV

Use Premolded cable termination for XLPE- and EPR-insulated 1-core cables with Al or Cu conductors and Cu-tape screen for 7.236 kV. The indoor termination can also be installed in a humid indoor environment*.

3
Standard Meets the requirements of: CENELEC HD 629.1 S1 IEEE 48 1996 Design Premolded cable termination made of silicone rubber with integrated field control and top sealing. The outdoor type is provided with permanent sheds for extended creepage distance. The indoor termination can also be installed in a humid indoor environment. The kits includes copper braids and constant force springs for connection of the Cu-tape screen to earth. One kit includes material for three single core terminations.
* For the best watertightness in an indoor humid environment, order branch seal kit TSH. See page 3/46.

Note: Cable lugs are to be ordered separately.

Always select products by Insulation diameter.


Insulation diameter mm 10.515 12.925.8 21.534.9 1115 1526 1526 2439 2439 2639 2639 1115 1524 1524 2233 2233 3140 2639 2639 1650 70185 240400 500630 2550 70185 240400 500630 1635 50120 150185 185240 300630 1635 50150 185240 300400 500630 7.2 kV Conductor cross section 12 kV 17.5 kV mm 2595 120185 240500 25120 150185 240300 400500 35120 150400 3570 95120 150240 300400 70185 240300 70185 240300 SOT 1013 R SOT 102-3 R SOT 103-3 S SOT 241A-3 R SOT 241-3 R SOT 241-3 S SOT 242-3 S SOT 242-3 T SOT 361-3 T SOT 361-3 U SOT 243A-3 R SOT 243-3 R SOT 243-3 S SOT 244-3 S SOT 244-3 T SOT 245-3 T SOT 361-3 T SOT 361-3 U 24 kV 36 kV Designation Size of copper braid mm 10 10 22 10 10 22 22 22 22 35 10 10 22 22 22 22 22 35
3/8

Indoor termination for three 1-core cables with Cu-tape screen

Outdoor termination for three 1-core cables with Cu-tape screen

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

Premolded cable termination for cables with Cu-tape screen SOT 7.236 kV

Use Premolded cable termination for XLPE- and EPR-insulated cables 3-core with Al or Cu conductors and Cu-tape screen for 7.236 kV.

Standard Meets the requirements of: CENELEC HD 629.1 S1 IEEE 48 1996 Design Premolded cable termination made of silicone rubber with integrated field control and top sealing. The outdoor type is provided with permanent sheds for extended creepage distance. The indoor termination can also be installed in a humid indoor environment. The kits includes Cu-braids and constant force springs for connection of the Cu-tape screen to earth. The kits also include branch seal and protective hoses of heat-shrink type. Note: Cable lugs are to be ordered separately.

Always select products by Insulation diameter.


Insulation diameter mm 10.515 12.925.8 12.925.8 21.434.9 1115 1526 1526 1526 2439 2439 2639 2639 1115 1524 1524 1524 2233 2533 3140 2639 2639 1650 70 95185 240400 2550 70 95185 240400 1635 50 70120 150185 185240 300400 1635 50 70150 185240 300400 7.5 kV Conductor cross section 12 kV 17.5 kV mm 2535 5095 120150 185 240400 2535 50120 150185 240400 35120 150400 3570 95120 150400 300400 70185 240300 70185 240300 SOT 1013 RC SOT 102-3 RC SOT 102-3 RD SOT 103-3 SD SOT 241A-3 RC SOT 2413 RC SOT 2413 RD SOT 2413 SD SOT 242-3 SD SOT 242-3 TD SOT 3613 TB SOT 3613 UB SOT 243A-3 RA SOT 243-3 RA SOT 243-3 RB SOT 243-3 SB SOT 244-3 SB SOT 244-3 TB SOT 245-3 TB SOT 3613 TB SOT 3613 UB 24 kV 36 kV Designation Size of Cu-braid mm 3 x 10 3 x 10 3 x 22 3 x 22 3 x 10 3 x 10 3 x 10 3 x 22 3 x 22 3 x 22 3 x 22 3 x 35 3 x 10 3 x 10 3 x 10 3 x 22 3 x 22 3 x 22 3 x 22 3 x 22 3 x 35

Indoor termination for 3-core cables with Cu-tape screen

Outdoor termination for 3-core cables with Cu-tape screen

3/9 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Dimensional drawings and accessories Premolded cable termination, SOT 1236 kV

I I Creepage distance L L I I

SOT, indoor

SOT, outdoor

Designation SOT 241/242/242 B SOT 243/244/245 SOT 246/361/362

I 235 330 390

L mm min 300 min 430 min 500

D 70/75/80 80/85

Creepage distance min 520 min 725

Accessories, to be ordered separately

SCL-B

UKR

FK

TSH

PSSK

Designation SCL-B UKR JSA, JXT FK TSH PSSK

Description Cable lug Universal clamp for fastening cable to a pole, etc. Earthing kits when the cable does not have a Cu-wire screen Overhead line clamp Branch seal kit Screen separation kit (if needed for indoor)

See page 3/51 7/2 3/47 3/50 3/46 3/45


3/10

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

Premolded cable termination with geometrical field control, indoors APIT 1236 kV

Use Cable termination with geometric field control for XLPE- and EPR-insulated 1- or 3-core cables. This type of termination is recommended to be used in applications were significant harmonics may occur.

3
Standard Meets the requirements of: CENELEC HD 629.1 IEEE 48-1975
A

Design The cable termination consists of a premolded stress relief cone with an integrated deflector for geometrical field control. The cables conducting layer is connected to the stress relief cone for optimal function. The termination is supplied in kits for 3-core cables. Note: Cable lugs and branch seal for 3-core cables are to be ordered separately.
Designation Insulation diameter Cable cross section mm APIT 4 APIT 5 APIT 6 APIT 7 APIT 8 APIT 9 APIT 10 APIT 11 APIT 12 APIT 13 25.028.0 27.530.5 30.533.6 33.036.6 35.739.7 39.343.1 42.548.1 48.054.0 54.060.0 60.066.0 mm 240 300 400 500 630 800 1000 1200 mm 170 170 170 170 170 170 170 170 12kV Creepage Length distance A mm 160 160 160 160 160 160 160 160 Cable cross section mm 120150 185240 300 400 500 500630 630800 1000 1200 mm 310 310 310 310 310 310 310 310 310 24kV Creepage distance A mm 300 300 300 300 300 300 300 300 300 Length Cable cross section mm 5095 95120 150240 240 300 400 500 630800 1000 1200 mm 460 460 460 460 460 460 460 460 460 460

Always select products by Insulation diameter.


36kV Creepage Length distance A mm 450 450 450 450 450 450 450 450 450 450 mm 96 96 96 96 96 96 96 96 99 99 kg/each 3.0 2.9 2.9 2.8 2.8 2.6 2.5 2.5 2.5 2.5 Diameter Weight

Accessories, to be ordered separately

SCL-B

UKR

FK

TSH

PSSK

Designation SCL-B UKR JSA FK TSH, SSH PSSK

Description Cable lug Universal clamp for fastening cable to a pole, etc. Earthing kits when the cable does not have a Cu-wire screen Overhead line clamp Branch seal kit and extension protective hoses Screen separation kit

See page 3/51 7/2 3/47 3/50 3/46 3/45

3/11 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Premolded termination with geometrical field control, outdoors APSEA 1236 kV

Use Cable termination with geometric field control for XLPE- and EPR-insulated 1- or 3-core cables. This type of termination is recommended to be used in applications were significant harmonics may occur. It is also suitable for environments where a longer creepage distance is required. Standard Meets the requirements of: CENELEC HD 629.1 IEEE 48-1975 Design The cable termination is made of rubber with prefabricated geometrical field control in the stress relief cone. The cables conducting layer is connected to the stress relief cone for optimal function. The creepage distance is built up with separate sheds and also a top cap that provides a diffusion sealed protection against the cable lug. The termination is supplied in kits for 3-core cables. Always select products by Insulation diameter.
Voltage Insulation diameter mm 25.028.0 27.530.5 30.533.6 33.036.6 35.739.7 39.343.1 42.548.1 48.054.0 25.028.0 27.530.5 30.533.6 33.036.6 35.739.7 39.343.1 42.548.1 48.054.0 54.060.0 25.028.0 27.530.5 30.533.6 33.036.6 35.739.7 39.343.1 42.548.1 48.054.0 54.060.0 60.066.0 Conductor cross section 12 12 12 12 12 12 12 12 24 24 24 24 24 24 24 24 24 36 36 36 36 36 36 36 36 36 36 mm 240 300 400 500 630 800 1000 1200 120150 185240 300 400 500 500630 630800 1000 1200 5095 95120 150240 240 300 400 500 630800 1000 1200 APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA APSEA 1213 122-3 123-3 124-3 125-3 126-3 127-3 128-3 2413 242-3 243-3 244-3 245-3 246-3 247-3 248-3 249-3 3613 362-3 363-3 364-3 365-3 366-3 367-3 368-3 369-3 3610-3 THS THS THS THS THS THS THS THSA THS THS THS THS THS THS THS THSA THSA THS THS THS THS THS THS THS THSA THSA THSA Designation Top cap type Creepage distance mm 300 300 300 300 300 300 300 300 830 830 830 830 830 830 830 830 830 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 Length A mm 255 255 255 255 255 255 255 255 470 470 470 470 470 470 470 470 470 580 580 580 580 580 580 580 580 580 580 Diameter mm 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165
APSEA 12 kV APSEA 24 kV

APSEA 36 kV

Note: Top caps are not included in the kit. Three pieces must be ordered separately. Top bolts, cable lugs and branch seal for 3-core cables are to be ordered separately.

Weight kg/kit 4.0 3.9 3.9 3.8 3.8 3.6 3.5 3.5 9.0 9.0 8.7 8.5 8.3 8,0 7.8 7.5 7.5 10.0 10.0 9.8 9.7 9.5 9.5 9.3 8.8 8.5 8.5
3/12

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

Premolded termination with geometrical field control, outdoor APSEA 1236 kV

Top caps, cable lugs and top bolts are supplied in one-piece kits, to be ordered separately. Top bolts and cable lugs The top cap THS or THSA is selected with regards to the size of the cable termination (see table at page 3/12) and the outer diameter of thickest part of the cable lug or top bolt. See dimension B in the table below.
Top hole Max. diameter of cable connection
THS, THSA Top cap.

Top cap THS THS 28 THS 37 THS 47 THS 60

Top cap THSA THSA 28 THSA 37 THSA 47 THSA 60 Cable conductor material Al Al Al Al Al Al Al Al Al Cu Cu Cu Cu Cu Cu Cu Cu Cu Al/Cu Al/Cu Al/Cu Al/Cu Al/Cu Net weight kg/item 0.5 0.5 0.8 0.8 0.9 0.9 1.2 1.2 1.1 1.6 1.6 2.4 2.4 2.8 2.8 4.0 3.8 3.5 0,10 0,25 0,30 0,35 0,90

mm 30 40 50 65 Accessory Diameter A mm Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Cable lug Cable lug Cable lug Cable lug Cable lug 30 30 30 30 30 30 40 40 40 30 30 30 30 30 30 40 40 40 24 28 33 38 50 B 45 45 50 55 60 60 65 65 65 45 45 50 55 60 60 65 65 65 24 28 33 38 52

Cable Designation cross section Top bolts mm 120 150, 185 240 300, 400 500 630 800 1000 1200 120 150, 185 240 300, 400 500 630 800 1000 1200 1095 25150 50240 70300 300630 A-TBF 30 120 SKR A-TBF 30 185 SKR A-TBF 30 240 SKR A-TBF 30 400 SKR A-TBF 30 500 SKR A-TBF 30 630 SKR A-TBF 40 800 SKR A-TBF 40 1000 SKR A-TBF 40 1200 SKR K-TBF 30 120 SKR K-TBF 30 185 SKR K-TBF 30 240 SKR K-TBF 30 400 SKR K-TBF 30 500 SKR K-TBF 30 630 SKR K-TBF 40 800 SKR K-TBF 40 1000 SKR K-TBF 40 1200 SKR SCL-B 95-12 SCL-B 150-12 SCL-B 240-12 SCL-B 300-16 SCL-B 630-16

125

B A/K-TBF SKR Top bolt. Tightening torque, 45 Nm.

A SCL-B Cable lug with shear-off bolts.

Accessories, to be ordered separately

Designation THS, THSA A/K-TBF SKR SCL-B


THS, THSA A/K-TBF SKR SCL-B UKR

Description Top caps for outdoor termination APSEA Top bolt Cable lug Universal clamp for fastening cable to a pole, etc. Overhead line clamp Branch seal kit and protective hoses Screen separation kit Earthing kits when the cable does not have a Cu-wire screen

See page 3/13 3/13 3/51 7/2 3/50 3/46 3/45 3/47

UKR FK TSH, SSH PSSK JSA

FK

TSH

SSH

PSSK

3/13 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Premolded screened separable cable connectors CSE-A 1224 kV, 250 A CSS-A 1224 kV, 250 A
Application areas Premolded screened separable connectors for XLPEand EPR-insulated 1- or 3-core cables with Al- or Cuconductors for 1224 kV. Can be installed both indoors and outdoors.

3
Fits standard bushings of outer cone type according to EN 50181. Connector with rated current: 250 A: Interface A with plug-in 7.9 mm. Standard Meets the requirements of: CENELEC, HD 629.1 S2 Design CSE-A and CSS-A are manufactured in rubber with three layers; a conductive inner layer, an insulation layer and a conductive outer layer, that are vulcanized together for the best possible interface between the layers. The cable connectors include both a capacitive test point with protection and an integrated earthing wire.
CSE-A 250 A, 1224 kV CSE-A 12250 CSE-A 24250 C-C 70 min CSS-A 12250 CSS-A 24250

63

124

29

58 211

Delivered in 3-phase kits, complete with cable lugs, bolt connection and stress grading adapter, designed to ensure a reliable installation. Note: For 3-core cable with common copper screen wires, a screen separation kit or a branch seal kit must be used. To be ordered separately.

C-C 80 min

66

65 263

Always select products by Insulation diameter.


Voltage kV 12 12 24 24 12 12 24 24 Insulation diameter mm 1012 1322 1322 1725.5 1012 1322 1322 1725.5 Conductor cross section mm 1016 2595 1016 2595 1016 2595 1016 2595 CSE-A 12250-01 CSE-A 12250-02 CSE-A 24250-01 CSE-A 24250-02 CSS-A 12250-01 CSS-A 12250-02 CSS-A 24250 01 CSS-A 24250 02 Designation Rated current A 250 250 250 250 250 250 250 250

CSS-A 250 A, 1224 kV

Weight kg/unit 2.2 2.2


1

C 2x45
R1

R3 31 32.5

Elbow cable connector

90 48.5

9 3.5

48 Bail holder

Elbow cable connector 2.2 2.2 2.2 2.2 2.2 2.2

Straight cable connector

4 Standard bushing EN 50181 Interface A, 250 A Contact type: Plug-in approx. 7.9 mm

Straight cable connector

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/14

Premolded screened separable connector for cables with Cu-tape screen CSE-A 1224 kV, 250 A
Application areas Premolded screened separable connectors for XLPE- and EPR-insulated 1- or 3-core 1224 kV cables with Al- or Cu-conductors with copper tape screens, with or without aluminium or steel wire armouring. Can be installed both indoors and outdoors. Fits standard bushings of outer cone type according to EN 50181. Connector with rated current: 250 A: Interface A with plug-in 7.9 mm. Standard Meets the requirements of: CENELEC, HD 629.1 S2 Design CSE-A is manufactured in rubber with three layers; a conductive inner layer, an insulation layer and a conductive outer layer, that are vulcanized together for the best possible interface between the layers. The cable connectors include both a capacitive test point with protection and an integrated earthing wire.
CSE-A 250 A, 1224 kV CSE-A 12250 CSE-A 24250 C-C 70 min

63

124

29

58 211

Delivered in 3-phase kits, complete with cable lugs, bolt connection, earthing kit and stress grading adapters. The adapters are designed to ensure a reliable installation. For 3-core cables, a branch seal kit is included.

Always select products by Insulation diameter.

Voltage

Insulation diameter mm connector, 1322 connector, 1925.5 connector, 1322 1322 connector, 1925.5

Conductor cross section mm 3 x 1-core 2595 3 x 1-core 3595 3-core 2550 7095 3-core 3595

Designation

Outer sheath diameter mm

Weight
90 48.5

C 2x45
R1

R3 31 32.5

kV Elbow cable 12 Elbow cable 24 Elbow cable 12 12 Elbow cable 24

kg/unit 2.7 2.7 2.9 2.9 2.9

CSE-A 12250-02 R CSE-A 24250-02 S CSE-A 12250-02 RA CSE-A 12250-02 RB CSE-A 24250-02 SB

3150 4470 4770

9 1

48 3.5 Bail holder

4 Standard bushing EN 50181 Interface A, 250 A Contact type: Plug-in approx. 7,9 mm

3/15 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Accessories, to be ordered separately Screened separable cable connectors CSE-A and CSS-A 1224 kV, 250 A

3
IH-A 24250 Insulating hood of flexible rubber with outer conductive layer and a preinstalled insulating rod. To be mounted on the bushing in a switchgear or a transformer 250 A to insulate it when a cable is temporarily disconnected but other cables are energized. PSSK Screen separation kit to achieve a metallic screen on each core for 3-core cables. JP 250 Earth circuit connector for short-circuit protective earthing. For mounting on the disconnected connector CSE-A for 250 A. Delivered in 3-phase kits in a case.

IP 250 Screened insulating plug for installation in the connector so that the cable can be energized even when disconnected from the switchgear or transformer 250 A.

TSH Branch seal kit to achieve a sealing on each core for 3-core cables.

CU 250 Coupling piece to connect two connectors.

PC 630/250 Parallel coupling piece. Replaces the plug in CSE-A 630 A when making a parallel connection to CSE-A 250 A. Delivered in 3-phase kits and hex bit socket.

MA 250 Measurement adapter used for mega ohm measurements and to perform different measurements up to 5 kV DC, for example determination of phases, 250 A.

Designation Description IH-A 24250 IP 250 PSSK TSH PC 630/250 JP 250 CU 250 MA 250 Insulating hood, 1224 kV, 250 A Screened insulating plug, 250 A Screen separation kit, heat-shrink for 3-core cable Branch seal kit Parallel coupling piece Earthing device, 250 A Coupling piece between two cable connectors, 250 A Measurement adapter, 250 A

Qty. per kit 3 1 1 1 3 3 1 1

Weight kg/kit 2.3 0,8 1.01.1 0.31.0 3.0 2.7 0.2 0.3

See page 3/16 3/16 3/45 3/46 3/16 3/16 3/16 3/16

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/16

Premolded screened separable cable connector CSE-A 1242 kV, 400 A

Application areas Premolded screened separable connector for XLPEand EPR-insulated 1- or 3-core cables with Al- or Cuconductors for 1242 kV. Can be installed both indoors and outdoors.

3
Fits standard bushings of outer cone type according to EN 50181. Connector with rated current: 400 A: series 400 interface type B with plug-in 14 mm.
CSE-A 12400 CSE-A 24400

Standard Meets the requirements of: CENELEC, HD 629.1 S2 Design CSE-A is manufactured in rubber with three layers; a conductive inner layer, an insulation layer and a conductive outer layer, that are vulcanized together for the best possible interface between the layers. The cable connector includes both a capacitive test point with protection and an integrated earthing wire.

80

C-C 85 min

173

34

72 256

CSE-A 400 A, 1224 kV

Delivered in 3-phase kits complete with cable lugs, bolt connection and stress grading adapter, designed to ensure a reliable installation. Note: For 3-core cables with common Cu-screen wires, a screen separation kit or a branch seal kit must be used. To be ordered separately.

80

C-C 85 min

195

34

74 284

CSE-A 400 A, 3642 kV

Always select products by Insulation diameter.


Voltage kV 12 12 24 24 36 36 42 42 Insulation diameter mm 1320 18.530.5 1724 22.535 24.534 27.542 24.534 27.542 Conductor cross section mm 2570 95300 2570 95300 50-95 95-300 5070 95300 CSE-A 12400-01 CSE-A 12400-02 CSE-A 24400-01 CSE-A 24400-02 CSE-A 36400-01 CSE-A 36400-02 CSE-A 42400-01 CSE-A 42400-02 Designation Rated current
102 70

Weight kg/unit 6.1 6.6 6.1 6.6 6.1 6.6 6.1 6.6
11

R3 R3

40

R3 46 56

A 400 400 400 400 400 400 400 400

90 5.5 Bail holder

Standard bushing EN 50181 Interface B, 400 A Contact type: Plug-in 14

3/17 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Accessories, to be ordered separately Screened separable cable connector CSE-A 1242 kV, 400 A

3
IH-A 24400, 42400 Insulating hood, of flexible rubber with outer conductive layer and a preinstalled insulating rod. To be mounted on the bushing in a switchgear or a transformer 400 A to insulate it when a cable is temporarily disconnected but other cables are energized. PSSK Screen separation kit to achieve a metallic screen on each core for 3-core cable.

IP 400 Screened insulating plug for installation in the connector so that the cable can be energized even when disconnected from the switchgear or transformer 400 A.

TSH Branch seal kit to achieve a sealing on each core for 3-core cable.

Designation Description IH-A 24400 IH-A 42400 IP 400 PSSK TSH Insulating hood, 1224 kV, 400 A Insulating hood, 36-42 kV, 400 A Screened insulating plug, 400 A Screen separation kit, heat-shrink for 3-core cable Branch seal

Qty. per kit 3 3 1 1 1

Weight kg/kit 5.2 5.5 2.2 1.01.1 0.31.0

See page 3/18 3/18 3/18 3/45 3/46

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/18

Premolded screened separable cable connector CSE-A 1242 kV, 630 A

Application areas Premolded screened separable connector for XLPEand EPR-insulated 1- or 3-core cables with Al- or Cu-conductors for 1242 kV. Can be installed both indoors and outdoors.

3
Fits standard bushings of outer cone type according to EN 50181. Connector with rated current: 630 A: Interface C1 with bolt M16. 1250 A: Interface C2 with bolt M16.
CSE-A 12630, CSE-A 24630 CSE-A 36630, CSE-A 42630 172 9

Standard Meets the requirements of: CENELEC, HD 629.1 S2 Design CSE-A is manufactured in rubber with three layers; a conductive inner layer, an insulation layer and a conductive outer layer, that are vulcanized together for the best possible interface between the layers. The cable connector includes both a capacitive test point with protection and an integrated earthing wire. Delivered in 3-phase kits, complete with cable lugs, bolt connection and stress grading adapter, designed to ensure a reliable installation. Note: For 3-core cables with common Cu-screen wires, a screen separation kit or a branch seal kit must be used. To be ordered separately.

81

C-C 85 min

72 256

CSE-A 630 A, 1224 kV, sizes 12 C-C 90 min

85

180

90 314

CSE-A 630 A, 1224 kV, size 3 C-C 85 min

81

194

Always select products by Insulation diameter.

74 70 283

R3 R3

29 1.5

R3 46 56

Voltage kV 12 12 12 24 24 24 36 36 36 42 42 42

Insulation diameter mm 1320 18.530.5 30.545 1724 22.535 30.545 24.534 27.542 38.055 24.534 27.542 3855

Conductor cross section mm 2570 95300 400630 2570 95300 400630 50-95 95-300 400-630 5070 95300 400630

Designation

Weight kg/unit 5.1 5.5 7.7 5.1 5.5 7.7 6.1 6.6 8.7 6.1 6.6 8.7

CSE-A 630 A, 3642 kV sizes 12. C-C 90 min

11

90

CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A

12630-01 12630-02 12630-03 24630-01 24630-02 24630-03 36630-01 36630-02 36630-03 42630-01 42630-02 42630-03

85

202

Standard bushing EN 50181 Interface: C1, 630 A Interface: C2, 1250 A Contact type: Bolt M16

90 314

CSE-A 630 A, 3642 kV size 3.

3/19 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Premolded screened separable cable connector for cables with copper tape screen CSE-A 1236 kV, 630 A
Application areas Premolded screened separable connector for XLPE- and EPR-insulated 1- or 3-core 1236 kV cables, with Al- or Cuconductors with Cu-tape screens, with or without aluminium or steel wire armouring. Can be installed both indoors and outdoors. Fits standard bushings of outer cone type according to EN 50181. Connectors with rated current: 630 A: interface type C1 with bolt M16. 1250 A: interface type C2 with bolt M16. Standard Meets the requirements of: CENELEC, HD 629.1 S2 Design CSE-A is manufactured in rubber with three layers; a conductive inner layer, an insulation layer and a conductive outer layer, that are vulcanized together for the best possible interface between the layers. The cable connector includes both a capacitive test point with protection and an integrated earthing wire. Delivered in 3-phase kits, complete with cable lugs, bolt connection, earthing kit and stress grading adapters. The adapters are designed to ensure a reliable installation. For 3-core cables, a branch seal kit is included.

CSE-A 12630 / CSE-A 24630 C-C 85 min

CSE-A 36630 172 9

81

72 256

CSE-A 630 A, 1224 kV, sizes 12 C-C 90 min

85

180

90 314

Always select products by Insulation diameter.


CSE-A 630 A, 1224 kV, size 3

Voltage kV

Insulation diameter mm

Conductor cross section mm

Outer sheath Designation diameter mm CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A CSE-A 12630-01 R 12630-02 S 12630-03 T 24630-01 S 24630-02 T 24630-03 T 36630-01 S 36630-02 T 36630-03 U 12630-01 12630-02 12630-02 12630-03 24630-01 24630-02 24630-03 36630-01 36630-02 RA SB TB TB SB TB TB SB TB

Weight kg/unit 5.6 6.0 8.2 5.6 6.0 8.2 6.8 7.3 9.4 5.8 6.2 6.2 8.4 5.8 6.2 8.4 6.8 7.3
81 C-C 85 min 194 9

Elbow cble connectors, 3 x 1-core cables 12 1320 2570 12 1929 95300 12 30.537 400 24 1924 3570 24 2535 95300 24 30.537 400 36 1929 5070 36 27.537 95300 36 3850 400

74 283

CSE-A 630 A, 3642 kV sizes 12. C-C 90 min

Elbow cable connectors, 3-core cables 12 1320 2570 3150 12 1929 95185 4770 12 2530.5 240300 5894 12 30.537 400 5894 24 1924 3570 4770 24 2535 95300 5894 24 30.537 400 65110 36 1929 5095 5894 36 27.537 95300 65110

85

202

90 314

CSE-A 630 A, 3642 kV size 3. 3/20

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

Accessories, to be ordered separately Screened separable cable connector CSE-A 1242 kV, 630 A

3
IH-A 24630, IH 42630 Insulating hood, of flexible rubber with outer conductive layer and a preinstalled insulating rod. To be mounted on the bushing in a switchgear or a transformer 630 A to insulate it when a cable is temporarily disconnected but other cables are energized. PSSK Screen separation kit to achieve a metallic screen on each core for 3-core cable. CSAP-A Surge arrestor, 630 A. CSEP-A Parallel cable connector.

PG 630 Bushing for voltage testing.

PC 630-3 L Parallel coupling piece, 36-42 kV. Delivered in 3-phase kits with hex bit socket.

IP 630 Screened insulating plug for installation in the connector so that the cable can be energized even when disconnected from the switchgear or transformer 630 A.

TSH Branch seal kit to achieve a sealing on each core for 3-core cable. PG-A 630 Bushing for voltage testing, 3642 kV. PC 630-3 Parallel coupling piece. Delivered in 3-phase kits with hex bit socket. JPB 630 Universal earthing device with two fields of application for 630 A and 12-42 kV: As earthing-for-work device mounted at the back of a connected cable connector CSE-A for 630 A. As short-circuit protective earthing mounted in front of a disconnected cable connector CSE-A for 630 A.

PC 630/250 Parallel coupling piece. Replaces the plug in CSE-A 630 A when making a parallel connection to CSE-A 250 A. Delivered in 3-phase kits and hex bit socket.

MA-A 630 Measurement adapter used for mega ohm measurements and to perform different measurements up to 5 kV DC, for example determination of phases, 630 A.

JPA V Tool for earthing device, JPB 630.

Designation Description IH-A 24630 IH-A 42630 IP 630 PC 630/250 PSSK TSH JPB 630 JPA V CSAP-A PG 630 PG-A 630 MA-A 630 CSEP-A PC 630-3 PC 630-3 L Insulating hood, 1224 kV, 630 A Insulating hood, 36-42 kV, 630 A Screened insulating plug, 630 A Parallel coupling piece Screen separation kit, heat-shrink for 3-core cable Branch seal Earthing device, 630 A Tool for earthing-for-work device, JPB 630 Surge arrestor, 630 A, 1224 kV Bushing for voltage testing, 630 A, 1224 kV Bushing for voltage testing, 630 A, 3642 kV Measurement adapter, 630 A Parallel cable connector Parallel coupling piece, 630 A Parallel coupling piece, 3642 kV

Qty. per kit 3 3 1 3 1 1 3 1 1 1 1 3 1 3 3

Weight kg/kit 5.2 5,5 2.2 3.0 1.01.1 0.31.0 5.0 1.8 3.65.0 1.5 2.0 0.2 5.79.8 3.3 3.6

See page 3/21 3/21 3/21 3/21 3/45 3/46 3/21 3/21 3/25 3/21 3/21 3/21 3/22 3/21 3/21

3/21 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Parallel separable connector for 630 A cable connector CSEP-A 1242 kV

Application area CSEP-A is a screened separable parallel cable connector designed to be connected to a screened separable cable connector type CSE-A 630. Used with XLPE- och EPRinsulated 1- or 3-core cables with Al- or Cu-conductor for 1242 kV. Standard Fulfills the requirements of CENELEC HD 629.1 S2. Design CSEP-A is manufactured in rubber with three layers; a conductive inner layer, an insulation layer and a conductive outer layer that are vulcanized together for the best possible interface between the layers. When installing CSEP-A on the CSE-A the plug and the protective cap must be moved from CSE-A to parallel connector CSEP-A. In that way the capacitive test point is re-established. Delivered in 3-phase kits complete with cable lugs, bolt connections, stress grading adapters and also an integrated earthing wire. Note: For 3-core cables with common Cu-screen wires, a screen separation kit or a branch seal kit must be used. For screen separation kit see table at page 3/45.

CSEP-A

100

81

min 85

72 256

CSEP-A, 1224 kV sizes 12 114 9 85 min 90

90 314

Always select products by Insulation diameter.

CSEP-A, 1224 kV size 3 122 9 81 min 85

Voltage kV 12 12 12 24 24 24 36 36 36 42 42 42

Conductor cross section mm 2570 95300 400630 2570 95300 400630 5095 95300 400630 5070 95300 400630

Insulation diameter mm 1320 18.530.5 30.545 1724 22.535 30.545 24.534 27.542 3855 24.534 27.542 3855

Designation

Weight
74

CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A

12630-01 12630-02 12630-03 24630-01 24630-02 24630-03 36630-01 36630-02 36630-03 42630-01 42630-02 42630-03

kg/kit 5.7 6.1 8.6 5.7 6.1 8.6 6.7 7.1 9.8 6.7 7.1 9.8

283

CSEP-A, 3642 kV sizes 12 136 9 85 min 90

90 314

CSEP-A, 3642 kV size 3

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/22

Parallel screened separable connector for cable with copper tape screen, 630 A CSEP-A 1236 kV
Application area CSEP-A is a screened separable parallel connector designed to be connected to a screened separable connector type CSE-A 630. Used with XLPE- and EPR-insulated 1- or 3-core 1236 kV cables, with Al- or Cu-conductors with copper tape screens, with or without aluminium or steel wire armouring. Standard Fulfills the requirements of CENELEC HD 629.1 S2. Design CSEP-A is manufactured in rubber with three layers; a conductive inner layer, an insulation layer and a conductive outer layer that are vulcanized together for the best possible interface between the layers. When installing CSEP-A on the CSE-A, the plug and the protective cap must be moved from CSE-A to the parallel connector CSEP-A. In that way the capacitive test point is re-established. Delivered in 3-phase kits complete with cable lugs, bolt connections, stress grading adapters and also an integrated earthing wire. Note: For 3-core cables with common Cu-tape screen, a screen separation kit or a branch seal kit must be used. See table at page 3/45.
72 256

CSEP-A

100

81

min 85

CSEP-A, 1224 kV sizes 12 114 9 85 min 90

90 314

Always select products by Insulation diameter.


Voltage Insulation Conductor Designation Weight kg/kit diameter cross section kV mm mm Parallel connector for 3 x 1-core cables 12 1320 2570 12 18.530.5 95300 12 30.545 400 24 1724 3570 24 22.535 95300 24 30.545 400 36 24.534 5070 36 27.542 95300 36 3855 400 Parallel connector for 3-core cables 12 1320 2570 12 18.530.5 95185 12 18.530.5 240300 12 30.545 400 24 1724 3570 24 22.535 95300 24 30.545 400 36 24.534 5095 36 27.542 95300

CSEP-A, 1224 kV size 3 122 9 81 min 85

74

CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A CSEP-A

12630-01 12630-02 12630-03 24630-01 24630-02 24630-03 36630-01 36630-02 36630-03 12630-01 12630-02 12630-02 12630-03 24630-01 24630-02 24630-03 36630-01 36630-02

R S T S T T S T U RA SB TB TB SB TB TB SB TB

5.8 6.2 8.7 5.8 6.2 8.7 6.8 7.2 9.9 5.8 6.2 6.2 8.7 5.8 6.2 8.7 6.8 7.2

283

CSEP-A, 3642 kV sizes 12 136 9 85 min 90

90 314

CSEP-A, 3642 kV size 3

3/23 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Dimensional drawings Parallel connection of CSE-A and CSEP-A 1242 kV Parallel connection of two CSE-A 1242 kV
Connection of parallel connector type CSEP-A to cable connector type CSE-A meets the requirements according to the standard CENELEC HD 629.1 S2.
278 289 286 298

1224 kV

97 CSEP-A size 12 + CSE-A size 12 316

105 CSEP-A size 3 + CSE-A size 12 330

101 CSEP-A size 12 + CSE-A size 3 324

109 CSEP-A size 3 + CSE-A size 3 339

3642 kV

113 CSEP-A size 12 + CSE-A size 12

124 CSEP-A size 3 + CSE-A size 12

117 CSEP-A size 12 + CSE-A size 3

128 CSEP-A size 3 + CSE-A size 3

Parallel connection of two cable connectors type CSE-A with parallel coupling piece PC 630-3 / PC 630-3 L meets the requirements according to the standard CENELEC HD 629.1 S2.
353 369 397 413

172 180 Parallel connection of two CSE-A size 12, 1224 kV Parallel connection of two CSE-A size 3, 1224 kV 194 Parallel connection of two CSE-A size 12, 36 kV 202 Parallel connection of two CSE-A size 3, 36 kV

Accessories, to be ordered separately:


Designation Description TSH, SSH Branch seal and additional hoses PSSK Screen separation kit See page 3/46 3/45

TSH

SSH

PSSK 3/24

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

Surge arresters for 630 A separable connector CSAP-A 1224 kV

Application area CSAP-A is a screened separable surge arrester designed to be connected in parallel with screened separable cable connector type CSE-A 630 A. Protects electrical components against overvoltage and transients. Standard Fulfills the requirements of IEC 60099-4. Parallel connection of surge arrester CSAP-A connected to cable connector CSE-A meets the requirements according to standard CENELEC HD 629.1 S2. Design CSAP-A includes a premolded body, manufactured in three layers; a conductive inner layer, an insulation layer and a conductive outer layer vulcanized together for the best possible interface between the layers. The surge arresters active part is made of metal oxide. The connected earth braid manages short circuit currents according to the standard. When installing CSAP-A on the CSE-A 630, the plug and the protective cap must be moved from CSE-A to the surge arrester CSAP-A. In that way the capacitive test point is re-established. Delivered in 1-core kits complete with bolt connection, earth braid and also an integrated earthing wire.
Voltage kV 12 12 24 24 Designation CSAP-A CSAP-A CSAP-A CSAP-A 12 12 24 24 5 kA 10 kA 5 kA 10 kA Weight kg/kit 3.6 4.0 4.6 5.0
90 90 266

CSAP-A

114

9 mm

85

min 90

CSAP-A sizes 12/5 and 12/10 114 9 mm 85 min 90

360

Explanation of symbols according to IEC 60099-4


Uc Ur Ures In Ihc Is continuous operating voltage rms rated voltage rms residual voltage peak at 8/20 s nominal discharge current 8/20 s high current impulse 4/10 s short circuit rating 50 Hz rms for 0.2 s
CSAP-A sizes 24/5 and 24/10 289 298

Technical data
Designation Uc [kA] CSAP-A CSAP-A CSAP-A CSAP-A 12 12 24 24 5 kA 10 kA 5 kA 10 kA 12 12 24 24 Ur [kA] 15 15 30 30 Ures [kA] 39.1 40 78.2 80 In [kA] 5 10 5 10 Ihc [kA] 65 100 65 100 Is [kA] 16 16 16 16 IEC line discharge class 1 1

CSE-A sizes 12 + CSAP-A

CSE-A size 3 + CSAP-A

3/25 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Shrouded termination, 630 A TB-A 12, 12 kV

Use Shrouded cable termination for connecting XLPEand EPR-insulated 12 kV cables in switchgear, type ABB SafeLink. Standard Meets the requirements of: CENELEC, HD 629.1 Design TB-A is a shrouded cable termination made of rubber. Supplied in complete 3-phase kits including cable terminations, two-piece boots, cable lugs with shear-off bolts, grease, cleaning cloth and installation instructions. Due to the smart installation method the upper part of the two-piece boot will stick to the bushing. For measuring, the lower part of the boot can easily be pulled down to expose the palm of the bushing. Note: For 3-core cables with common Cu-screen wires, a screen separation kit or a branch seal kit must be used.

Connector cross section mm

Designation

Length mm

Weight kg/kit 2.65 2.90 3.10

Three 1-core or one 3-phase kits 1035 50150 185300 TB-A 12630-1 TB-A 12630-2 TB-A 12630-3 400 400 450

Accessories, to be ordered separately

PSSK

TSH

Designation PSSK TSH

Description Screen separation kit Branch seal

See page 3/45 3/46

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/26

Shrouded termination, 630 A KAP 630, 1224 kV

Use For XLPE- and EPR-insulated 1- or 3-core cables with Al or Cu conductor for 1224 kV. KAP can be used to connect a cable to gas-insulated switchgear and in other compact installations, as well as for substation transformers. To be used indoors only. Standards Meets the requirements of: SEN 24 14 34 SS 424 14 17 Edition 4 Design KAP is an insulated connector made of rubber. It is supplied complete with cable termination and bolt cable lug. The covers are provided with a removable plastic plug to allow direct voltage testing on the conductor.
86

~316 185 130

Also available for parallel installation. The connectors are supplied in 3-phase kits. Note: For 3-core cables with common Cu-screen wires, a screen separation kit or a branch seal kit must be used. For plug-in connector 250 A or 400 A, choose CSE-A.
260

C-C 133 70 KAP 630 SCL KAP 630 P SCL Installed in parallel with KAP 630 SCL.

Always select products by Insulation diameter.


Type Insulation diameter Standard Standard Parallel Parallel mm 1525 2437 1525 2437 Conductor cross section 12 kV mm 50150 185300 50150 185300 2595 120300 2595 120300 KAP KAP KAP KAP 630-1 SCL 3 630-2 SCL 5 630 P-1 SCL 3 630 P-2 SCL 5 Bolt Bolt Bolt Bolt M16 M16 M16 M16 24 kV Designation Connection type kg/item 2.2 2.5 2.5 2.5 Weight

3/27 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Dimensional drawings and accessories KAP 630

The indicated recommended minimum distances are generally applicable. For applications in which type testing has been performed, other minimum distances may be applied. This is the case, for example, for gas-insulated Ring Main Unit (RMU).
A B C D

3
D

Recommended minimum distances

Recommended minimum air gap


Voltage kV 12 24 Insulation level kV 75 125 50 90 10 30 A B mm 90 110 10 50 C D

Accessories, to be ordered separately

PSSK

TSH

Designation PSSK TSH

Description Screen separation kit Branch seal

See page 3/45 3/46

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/28

Insulating boot KAP 300 U, 1224 kV

Use For XLPE- and EPR-insulated 1- or 3-core cables with Al or Cu conductor, for 1224 kV, indoors. KAP 300 U is especially well suited for the renovation of, for example, oil-filled transformer boxes, when replacing paper-insulated cable with XLPE-insulated cable. An indoor termination type SOT (must be ordered separately) is installed together with KAP 300 U on the XLPE-insulated cable, thus insulating the connection point when the oil is drained from the cable box. KAP 300 U can also be mounted straight. Standards Meets the requirements of: SEN 24 14 34 SS 424 14 17 Edition 4 Design An insulating boot made of rubber. The covers are fitted with a removable plastic plug to allow direct voltage testing on the conductor. Note: For 3-core cables with common Cu-screen wires, a screen separation kit or a branch seal kit must be used. See dimensional drawings for minimum distance to earth. Termination and cable lug are not included.
Conductor cross section Designation 12 -24 kV mm 25300 KAP 300-U Bolt kg/item 2.0 Specification Weight
78

210

195

345

44 Elbow KAP 300 U. Straight KAP 300 U.

Recommended minimum distances The indicated recommended minimum distances are generally applicable. Recommended minimum air gap
Voltage kV Insulation level kV 75 125
A B C D

A 50 110

B mm 10 50

C 90 130

D 10 50

Accessories, to be ordered separately

12 24

PSSK

TSH

SOT

SCL-B

Designation PSSK, PSSK-E, PSSK L TSH SCL-B SOT

Description Screen separation kit Branch seal kit Bolt cable lug Cable termination

See page 3/45 3/46 3/51 3/6

3/29 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Premolded cable joint with cold shrink outer jacket SOJ 1224 kV

Use Premolded cable joint for XLPE- and EPR-insulated 1- or 3-core cables with Al or Cu conductor, 1224 kV. Standards CENELEC, HD 629.1 S1 SS 424 14 45 Edition 1 VDE 0278 KEMA S8 IEEE 404 1993

SOJ CSS

3
The kits are selected as follows: SOJ CSS Contains cold-shrink outer jacket and connectors with shear-off bolts for conductor and screen.

Design The joint body is made of rubber in three layers: a conductive SOJ CS Contains cold-shrink outer jacket. Connectors are not outer layer, an insulating layer and a conductive inner layer. included. The kit contains all mounting material. The joint body is pre-expanded on plastic inserts before installation. When the cables have been connected and the joint is centred, the inserts are pulled out. This way the joint body will provide an active pressure on the cable insulation and will follow variations in the cable during load. Always select products by Insulation diameter.
Insulation diameter mm 1519.5 18.524 2328 2734 33.5-46 1923.5 22.528 2735 2735 33.5-46 33.5-46 5070 95150 185240 300400 500630 Cable cross section 12 kV mm 5070 95150 185240 300 400 500630 SOJ 244-1 SOJ 121-1 SOJ 122-1 SOJ 123-1 SOJ 124-1 SOJ 125-1 SOJ 241-1 SOJ 242-1 SOJ 243-1 24 kV Designation 1-core CSS Weight kg/kit 2.5 2.6 3.4 4.7 5.5 3.3 3.6 4.3 4.5 5.3 5.5 CS Weight kg/kit 2.4 2.5 3.2 4.2 4.8 3.2 3.5 4.0 4.0 4.8 4.8 SOJ 1213 SOJ 122-3 SOJ 123-3 SOJ 124-3 SOJ 2413 SOJ 242-3 SOJ 243-3 Designation 3-core CSS Weight kg/kit 5.0 5.5 7.0 5.8 6.9 8.8 CS Weight kg/kit 4.7 5.2 6.2 7.3 5.5 6.5 8.0

Note: For 1635 mm cables ADAPTER must be ordered separately, see following pages. WIM 3 to be used as complement when jointing 3-core watertightened cable, see following pages.

Accessories, to be ordered separately


D

ADAPTER

TS

WIM

SH-SKRM

Accessories ADAPTER TS WIM 3 SH-SKRM JSA 1013 JSA 1416

Use Cables with different dimensions Additional kit for sector shaped 3-core cables Diffusion seal Bolt connector Cables with Cu-tape screen Cables with Al-foil screen

SOJ CSS X X X X X

SOJ CS X X X X X X

See page 3/36 3/36 3/37 3/51 3/48 3/48


3/30

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

Premolded cable joint for radially watertightened cable SOJ 1224 kV

Use Premolded cable joint for XLPE- and EPR-insulated 1- or 3-core cables with Al- or Cu-conductor and radially watertightened aluminium foil for 1224 kV.

SOJ CSWS

Standards Meets the requirements of: CENELEC, HD 629.1 S1 SS 424 14 45 edition 1 VDE 0278 KEMA S8 IEEE 404 1993 Design The joint body is made of rubber in three layers: a conductive outer layer, an insulating layer and a conductive inner layer. The kit contains all mounting material. The joint body is pre-expanded on plastic inserts before installation. When the cables have been connected and the joint is centred, the inserts are pulled out. This way the joint body will provide an active pressure on the cable insulation and will follow variations in the cable during load. The kits are selected as follows: SOJ CSWS Used for jointing watertightened 1-core cables with Cu-wire screen. Contains cold-shrink outer jacket, Al-foil tube and connectors for conductor and screen.
Insulation diameter mm 1519.5 18.524 2328 2734 33.546 1923.5 22.528 2735 33.546 33.546 5070 95150 185240 300400 500630 Cable cross section 12 kV mm 5070 95150 185240 300400 500630 SOJ 121-1 50 SOJ 122-1 95 150 SOJ 123-1 240 SOJ 124-1 400 SOJ 125-1 630 SOJ 241-1 50 SOJ 242-1 95 150 SOJ 243-1 240 SOJ 244-1 400 SOJ 244-1 630 24 kV Designation 1-core CSWS Weight kg/kit 3.0 3.2 4.0 5.3 6.1 3.9 4.2 4.9 5.9 6.1

SOJ RWI

SOJ RWIT

SOJ RWI Used for jointing three 1-core cables, Prysmian type WISKITM or similar. Contains copper braids to connect screens, Al foil tubes for radially watertightness and also outer jacket RULLE. Connectors and items for jointing of separate earth wire are not included. SOJ RWIT Used for jointing three 1-core cables Prysmian type WISKITM or similar, to a standard 3-core cable. Contains copper braids to connect screens, STOP longitudinal watertightness and outer jacket RULLE. Connectors and articles for jointing a separate earth wire are not included. Note: For 1635 mm cables, ADAPTER must be ordered separately, see the table below. Always select products by Insulation diameter.
RWI Weight kg/kit 7.3 7.9 10.3 10.0 10.9 13.0 RWIT Weight kg/kit 5.0 5.5 7.0 5.5 6.5 8.0

Designation 3 x 1-core SOJ 12131 SOJ 122-31 SOJ 123-31 SOJ 24131 SOJ 242-31 SOJ 243-31

Accessories, to be ordered separately


D

ADAPTER

TS

SH-SKRM

Accessories Adapter TS SH-SKRM

Use Adapter kit for cables with different dimensions Additional kit for sector shaped cables Bolt connector

SOJ CSWS X

SOJ RWI X X X

SOJ RWIT X X X

See page 3/36 3/36 3/51

3/31 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Premolded cable joint with or without outer jacket, RULLE SOJ 1224 kV

Use Premolded cable joint for XLPE- and EPR-insulated 1- or 3-core cables with Al or Cu conductor for 1224 kV. Standards Meets the requirements of: CENELEC, HD 629.1 S1 SS 424 14 45 edition1 VDE 0278 KEMA S8 IEEE 404 1993 Design The joint body is made of rubber in three layers: a conductive outer layer, an insulating layer and a conductive inner layer. The joint body is pre-expanded on plastic inserts before installation. When the cables have been connected and the joint is centred, the inserts are pulled out. This way the joint body will provide an active pressure on the cable insulation and will follow variations in the cable during load.
Insulation diameter mm 1519.5 18.524 2328 2734 33.546 1923.5 22.528 2735 33.546 5070 95150 185240 300400 500630 Cable cross section Designation 12 kV mm 5070 95150 185300 400 SOJ 121-1 SOJ 122-1 SOJ 123-1 SOJ 124-1 SOJ 125-1 SOJ 241-1 SOJ 242-1 SOJ 243-1 SOJ 244-1 24 kV 1-core R Weight kg/kit 2.6 3.0 3.1 4.3 5.9 3.2 3.9 4.5 6.4

SOJ R

The kits are selected as follows: SOJ R Contains outer jacket RULLE; a two-layer tape of EPDMrubber and mastic, which is wrapped around the joint. Connectors are not included. SOJ SL Supplied without outer jacket. An outer jacket approved by us must be added, for example type ARM. Connectors are not included. Note: For 1635 mm cables ADAPTER must be ordered separately, see the table below. WIM 3 / WIM 4 used as complement when jointing 3-core watertightened cable, see the table below. Always select products by Insulation diameter.
SL kg/kit SOJ 121-1 SL SOJ 122-1 SL SOJ 123-1 SL SOJ 124-1 SL SOJ 125-1 SL SOJ 241-1 SL SOJ 242-1 SL SOJ 243-1 SL SOJ 244-1 SL 1.0 1.1 1.2 1.6 2.2 1.3 1.5 1.8 2.2 SOJ 1213 SOJ 122-3 SOJ 123-3 SOJ 124-3 SOJ 2413 SOJ 242-3 SOJ 243-3 Designation R Weight kg/kit 4.7 5.6 6.4 8.9 6.2 7.0 9.1 SOJ 1213 SL SOJ 122-3 SL SOJ 123-3 SL SOJ 124-3 SL SOJ 2413 SL SOJ 242-3 SL SOJ 243-3 SL Designation 3-core SL Weight kg/kit 2.0 2.3 2.7 4.2 2.8 3.4 4.5

Designation 1-core

Weight 3-core

Accessories, to be ordered separately


D

ADAPTER

TS

WIM

STOP

SH-SKRM

Accessories Adapter JSA 1013 JSA 1416 TS WIM ARM STOP SH-SKRM

Use Cables with different dimensions Cables with Cu-tape screen Cables with Al-foil screen Additional kit for sector shaped 3-core cables Diffusion seal Armouring kit Crutch seal when 3 x 1-core cables are jointed to a 3-core Bolt connector

SOJ R X X X X X X X

SOJ SL X X X X X X X

See page 3/36 3/48 3/48 3/36 3/37 3/49 3/36 3/51

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/32

Premolded cable joint with heat-shrink outer jacket SOJ HSTS 1224 kV

Use Premolded cable joint with heat-shrink outer jacket and bolt connector. For jointing 1224 kV XLPE- and EPRinsulated 1- or 3-core cables with Al- or Cu-conductors.
SOJ HSTS 3-core kit

Standard Meets the requirements of: SS 424 14 45 edition 1 VDE 0278 CENELEC, HD 629.1 S1 KEMA S8 IEEE 404 1993 Design The joint body is made of rubber in three layers: a conductive outer layer, an insulating layer and a conductive inner layer. The joint kit is complete and restores all the parts of the cable. The joint body is pre-expanded on plastic inserts before installation. When the cables have been connected and the joint is centred, the inserts are pulled out. This way the joint body will provide an active pressure on the cable insulation and will follow variations in the cable during load.

The kits include: Heat-shrink outer jacket, vulcanizing tape and connectors with shear-off bolts for conductor and screen. Note: For 1635 mm cables ADAPTER must be ordered separately, see the table below. WIM 3 / WIM 4 used as complement when jointing 3-core watertightened cable, see the table below.

Always select products by Insulation diameter.

Voltage kV Cable joint 12 12 12 12 12 Cable joint 12 12 12 12 Cable joint 24 24 24 24 24 24 Cable joint 24 24 24

Insulation diameter mm for 1-core 1519.5 18.524 2328 2734 33.546 for 3-core 1519.5 18.524 2328 2734 for 1-core 1923.5 22.528 2735 2735 33.546 33.546 for 3-core 1923.5 22.528 2735

Conductor cross section mm 5070 95150 185240 300400 500630 5070 95150 185240 300400 5070 95150 185240 300 400 500630 5070 95150 185240 SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ

Designation

Weight kg/kit

Accessories, to be ordered separately

121-1 122-1 123-1 124-1 125-1 121-3 122-3 123-3 124-3 241-1 242-1 243-1 243-1 244-1 245-1

70 HSTS 150 HSTS 240 HSTS 400 HSTS 630 HSTS 70 HSTS 150 HSTS 240 HSTS 400 HSTS 70 HSTS 150 HSTS 240 HSTS 300 HSTS 400 HSTS 630 HSTS

2.5 2.6 3.4 4.7 5.5 5.0 5.5 7.0 9.1 3.3 3.6 4.3 4.5 5.3 5.5 5.8 6.9 8.8

ADAPTER

WIM

Accessories Adapter WIM JSA 1013 JSA 1416

Use Cables with different dimensions Diffusion seal Cables with copper tape screen Cables with Al-foil screen

See page 3/36 3/37 3/48 3/48

SOJ 241-3 70 HSTS SOJ 242-3 150 HSTS SOJ 243-3 240 HSTS

3/33 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Premolded cable joint with heat-shrink outer jacket SOJ HSTS 36 kV

Use Premolded cable joint with heat-shrink outer jacket and bolt connector. For jointing 36 kV XLPE- and EPRinsulated 1- or 3-core cables with Al or Cu conductors.
SOJ HSTS 3-core kit

Design The joint body is made of rubber in three layers: a conductive outer layer, an insulating layer and a conductive inner layer. The joint kit is complete and restores all the parts of the cable. The joint body is pre-expanded on plastic inserts before installation. When the cables have been connected and the joint is centred, the inserts are pulled out. This way the joint body will provide an active pressure on the cable insulation and will follow variations in the cable during load.

3
The kits are included: Heat-shrink outer jacket, vulcanizing tape and connectors with shear-off bolts for conductor and screen. Note: For 1635 mm cables ADAPTER must be ordered separately, see the table below. WIM 3 / WIM 4 used as complement when jointing 3-core watertightened cable, see the table below. Cable joint must be selected according to Insulation diameter and conductor cross section.

Always select products by Insulation diameter.

Voltage kV Cable joint 36 36 36 36 36 36 36 36 Cable joint 36 36 36 36 36 36 36 36

Insulation diameter mm for 1-core 1923.5 22.528 22.528 2735 2735 33.546 33.546 33.546 for 3-core 1923.5 22.528 22.528 2735 2735 33.546 33.546 33.546

Conductor cross section mm 5070 5070 95 95150 185240 185240 300400 500 5070 5070 95 95150 185240 185240 300400 500

Designation

Weight kg/kit

Accessories, to be ordered separately

SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ SOJ

361-1 362-1 362-1 363-1 363-1 364-1 364-1 365-1 361-3 362-3 362-3 363-3 363-3 364-3 364-3 365-3

70 HSTS 70 HSTS 95 HSTS 150 HSTS 240 HSTS 240 HSTS 400 HSTS 500 HSTS 70 HSTS 70 HSTS 95 HSTS 150 HSTS 240 HSTS 240 HSTS 400 HSTS 500 HSTS

3.3 3.6 3.6 4.3 4.3 5.2 5.3 5.5 5.8 6.9 6.9 8.8 8.8 10.6 10.7 10.9

ADAPTER

WIM

Accessories Adapter WIM JSA 1013 JSA 1416

Use Cables with different dimensions Diffusion seal Cables with Cu-tape screen Cables with Al-foil screen

See page 3/36 3/37 3/48 3/48

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/34

Premolded cable joint, for cables with Cu-tape screen SOJ EA 1224 kV

Use Premolded cable joint for XLPE- and EPR-insulated 1- or 3-core cable with Al or Cu conductors and Cu-tape screen for 1224 kV.

Standards Meets the requirements of: SS 424 14 45 edition 1 VDE 0278 CENELEC, HD 629.1 S1 KEMA S8 IEEE 404 1993 Design The joint body is made of rubber in three layers: a conductive outer layer, an insulating layer and a conductive inner layer. The joint body is pre-expanded on plastic inserts before installation. When the cables have been connected and the joint is centred, the inserts are pulled out. This way the joint body will provide an active pressure on the cable insulation and will follow variations in the cable during load.
Insulation diameter mm 1519.5 18.524 2328 2734 1923.5 22.528 2735 5070 95150 185240 300400 Cable cross section 12 kV mm 5070 95150 185300 SOJ 1213 EA SOJ 122-3 EA SOJ 123-3 EA SOJ 124-3 EA SOJ 2413 EA SOJ 242-3 EA SOJ 243-3 EA 24 kV Designation

The kits are selected as follows: SOJ EA Contains copper stockings and constant force springs to restore the Cu-tape screen and cast resin armouring kit to restore the outer jacket. Note: Connectors for the cable conductors are not included and must be ordered separately.

Always select products by Insulation diameter.

Accessories, to be ordered separately


D

ADAPTER

TS

WIM

SH-SKRM

Accessories Adapter TS WIM ARM SH-SKRM

Use Cables with different dimensions Additional kit for sector shaped 3-core cables Diffusion seal Armouring kit Bolt connector

See page 3/36 3/36 3/37 3/49 3/51

3/35 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Accessories, to be ordered separately Premolded cable joint, SOJ 1224 kV

Additional kit TS Additional kit for sector shaped 3-core cables, for use when the D-dimension over the insulation is above the value as below.
Designation TS 121 TS 242 TS 243 Fitting joint SOJ 1213 SOJ 242-3 SOJ 243-3 D mm 20 29 39 Weight kg/item 0.1 0.1 0.1

Adapter kit, ADAPTER Adapter for cables from 10 mm and for jointing cables with a smaller cross section. Manufactured and tested to take one step down to the nearest joint size (each kit contains one adapter).

Designation

Fitting joint

Minimum conductor cross section mm

Insulation diameter mm Minimum 10 15.019.5 18.524.0 19.023.5 23.028.0 22.528.0 27.034.0 27.035.0 23.028.0 22.528.0

Weight kg/item 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1

ADAPTER 1* ADAPTER 2 ADAPTER 3 ADAPTER ** ADAPTER 5 ADAPTER 6**

SOJ 121,241 SOJ 122 SOJ 123 SOJ 242, 362 SOJ 124 SOJ 243, 363 SOJ 125 SOJ 244, 364 SOJ 125 SOJ 244, 364

10 50 95 50 185 95 300 185 185 95

* Minimum diameter over connector is 12 mm. ** ADAPTER 6 takes a larger outer diameter than ADAPTER 4 to t SOJ 125, SOJ 244 and SOJ 364.

Crutch seal, STOP For sealing when three 1-core cables are jointed to a 3-core cable.
Designation Voltage kV STOP 1 12 24 36 STOP 2 12 24 36 Suitable for 1-core cables with conductor cross section mm 50185 5095 5095 > 240 > 120 > 120 kg/item 0.2 0.2 0.2 0.2 0.2 0.2 Weight

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/36

Accessories, to be ordered separately Premolded cable joint, SOJ 1224 kV

Diffusion seal, WIM Used as complement to SOJ CS, SOJ CSS or SOJ R when jointing 1- or 3-core watertightened cables with diffussion barrier of aluminium.

3
WIM 3

Designation WIM 3

Fitting joint SOJ 1213, 122-3, 123-3 SOJ 2413, 242-3, 243-3 SOJ 361-3, 362-3, 364-3

Type of cable 3-core with Al foil in direct contact with screen 1-core with Al-foil in direct contact with screen 1-core with Al-foil in direct contact with screen

Weight kg/kit 0.5

WIM 5 WIM 6

SOJ 121-1, SOJ 122-1 SOJ 123-1, SOJ 124-1, SOJ 125-1 SOJ 241-1, SOJ 242-1, SOJ 243-1 SOJ 244-1, SOJ 245-1, SOJ 361-1 SOJ 362-1, SOJ 363-1, SOJ 364-1, SOJ 365-1

0.4 0.4

Accessories, to be ordered separately


D

ADAPTER

TS

WIM

STOP

SH-SKRM

To be ordered separately
Accessories ADAPTER TS WIM STOP SH-SKRM JSA 1013 JSA 1416 ARM Description Cables with different dimensions Additional kit for sector shaped 3-core cables Diffusion seal Crutch seal when 3 x 1-core cables are jointed to a 3-core Bolt connector Earthing kit for cable with Cu-tape screen Earthing kit for cable with Al-foil screen only Armoured cable or when extra mechanical protection is required CSS X X X X X X CS X X X X X X R X X X X X X X SL X X X X RWI X X RWIT X X HSTS See page X X X X X X 3/36 3/36 3/37 3/36 3/51 3/48 3/48 3/49

3/37 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Dimensional drawings Premolded cable joint, SOJ 1224 kV

B C

A A

3
SOJ with cold-shrink outer jacket for watertightened 1-core cables.

SOJ with cold-shrink outer jacket. B

B C

SOJ with RULLE outer jacket on 3 x 1-core WISKITM cables.

SOJ with RULLE outer jacket on 3 x 1-core WISKI TM cables to a 3-core XLPE-insulated cable. B

Designation A* 1-core SOJ 121-1 SOJ 122-1 SOJ 123-1 SOJ 124-1 SOJ 125-1 SOJ 241-1 SOJ 242-1 SOJ 243-1 SOJ 244-1 SOJ 361-1 SOJ 362-1 SOJ 363-1 SOJ 364-1 SOJ 365-1 3-core SOJ 121-3 SOJ 122-3 SOJ 123-3 SOJ 124-3 SOJ 241-3 SOJ 242-3 SOJ 243-3 SOJ 361-3 SOJ 362-3 SOJ 363-3 SOJ 364-3 SOJ 365-3

Dimensions B* mm 9701050 9801090 10701150 11901270 12801400 10101090 10701150 11901270 12801400 1070 1110 1240 1280 1280 11201150 11701270 1310 13501470 12101240 12601310 13301450 1240 1310 1450 1600 1600 740850 780890 820950 9701070 9801200 770890 810950 9401070 9801200 770 810 940 980 980 8501000 9701150 10101190 11701310 9401090 10101140 11501310 940 1010 1150 1300 1300 60 65 75 75 90 75 80 85 90 75 80 85 90 90 120 125 140 165 145 160 180 145 160 180 200 200
A SOJ with heat-shrink outer jacket.

C*

B C

SOJ with cast resin as armouring outer jacket.

SOJ with RULLE outer jacket.

*Estimated dimensions depending on installation and type of outer jacket.

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/38

Tape cable joint SMXB 1236 kV

Use For jointing XLPE- and EPR-insulated 1- and 3-core cables with Al or Cu conductor 1236 kV. Standard Meets the requirements of: SEN 24 14 34 SS 424 14 17 Edition 4 VDE 0278 Design The joint kit consists of tapes, stress grading pads FSD and a copper net. Note: Connectors for conductor and screen and welding equipment are not included.

Designation

Weight kg/item

Designation 1 x 1-core cable SMXB 1-1 SMXB 2-1 SMXB 3-1 SMXB 4-1 SMXB 5-1 SMXB 6-1 SMXB 7-1 SMXB 8-1 SMXB 9-1 SMXB 10-1 SMXB 11-1 SMXB 12-1 SMXB 13-1

Weight kg/item 0.9 1.1 1.4 1.6 2.0 2.2 2.5 3.6 5.1 3.8 5.1 6.7 7.8

1 x 3-core or 3 x 1-core cables SMXB 13 SMXB 2-3 SMXB 3-3 SMXB 4-3 SMXB 5-3 SMXB 6-3 SMXB 7-3 SMXB 8-3 SMXB 9-3 For selecting size see next page. 2.6 3.7 4.0 4.3 4.5 5.9 6.7 9.7 12.9

To be ordered separately

STOP

WIM

SH-SKRM

Accessories STOP WIM SH-SKRM JSA 14-16

Description Crutch seal when 3 x 1-core cables are jointed to a 3-core Diffusion seal Bolt connector Earthing kit for cable with Al-foil screen only

See page 3/36 3/36 3/51 3/48

3/39 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Tables for selection of tape cable joint SMXB 1236 kV

For compression of aluminium conductors


Voltage Insulation thickness 10 kV mm One 3-core or three 1-core cables 12 3.4 24 5.5 One 1-core cable 36 8.0 25 35 50 70 95 Cross section 120 150 mm Cable joint SMXB No. 1 1 1 1 2 3 4 4 Cable joint SMXB No. 10 10 10 1 4 10 2 5 10 2 5 10 2 6 10 3 6 11 3 6 11 6 8 11 7 8 11 7 8 11 8 9 12 185 240 300 400 500 630

For compression of Cu-conductors


Voltage Insulation thickness 25 kV mm One 3-core or three 1-core cables 12 3.4 24 5.5 One 1-core cable 36 8.0 30 50 70 95 120 Cross section 150 185 mm Cable joint SMXB No. 1 1 1 1 3 3 3 3 10 10 10 10 1 3 10 1 5 10 2 5 10 2 5 11 3 6 11 3 6 11 7 7 11 7 8 11 7 8 11 13 13 240 300 400 500 630 800 1200

For thermite welding of aluminium or Cu-conductors


Voltage Insulation thickness 400 kV mm One 3-core or three 1-core cables 12 3.4 24 5.5 One 1-core cable 36 8.0 500 Cross section 630 800 1000 1200

Always select products by Insulation diameter.

mm Cable joint SMXB No. 7 7 7 7 8 8 Cable joint SMXB No. 11 11 11 11

12

12

Accessories, to be ordered separately STOP Crutch seal for sealing when 3 x 1-core cables are jointed to a 3-core cable.
Designation Voltage kV STOP 1 12 24 36 STOP 2 12 24 36 Suitable for 1-core cables with conductor cross section mm 50185 5095 5095 >240 >120 >120 kg/item 0.2 0.2 0.2 0.2 0.2 0.2 Weight

WIM Diffusion seal kits for restoring radial watertightness on cables with diffusion barrier of aluminium.
Designation WIM 1 WIM 2 WIM 3 Fitting joint SMXB 1-1, 2-1, 3-1, 4-1 SMXB 5-1, 6-1, 7-1, 8-1,9-1,10-1,11-1,12-1 SMXB 13, 2-3, 3-3, 4-3, 5-3, 6-3 Type of cable 1-core with Al-foil 1-core with Al-foil 3-core with Al-foil in direct contact with screen Weight kg/kit 0.5 0.5 0.3
3/40

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

Cable cabinet, 250 A HDC-A 1224 kV

Use For jointing or branching XLPE- and EPR-insulated 1-core or 3-core, 1224 kV cables with conductor cross sections 2595 mm, 250 A.

When branching in a cable grid, a branching point may be necessary to enable selected cable runs to be sectionalized during maintenance. With HDC-A, a solution is provided that makes this possible. Up to three cables can be connected in parallel. Standards Enclosure meets the requirements of mechanical impact tests according to: IEC 60439-5 Cable connectors meet the requirements of electrical tests according to CENELEC, HD 629.1 S2 Design The enclosure is made of hot-dip-galvanized sheet steel plates with a foundation base plate and additional corrosion protection on parts that will be buried under ground.
Overall height 1293 mm Height above ground level,993 mm

312 mm 996 mm

The screened separable cable connectors are connected with coupling pieces pre-mounted in the cabinet. The cable cabinet is supplied with: 9 screened separable connectors Standard locks and padlock shackle Note: For 3-core cables, branch seal kit type TSH or screen separation kit type PSSK must be used. To be ordered separately. For foundation kit for floor installation, contact us.

Always select products by Insulation diameter.

Voltage kV 12 24

Insulation diameter Conductor cross section Designation basic configuration mm mm 1322 1725.5 2595* 2595* HDC-A 12250 HDC-A 24250

Weight kg /unit 117 117

* For cables smaller than 25 mm, contact us.

3/41 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Accessories, to be ordered separately Cable cabinet, HDC 1224 kV, 250 A

3
IP 250 Screened insulating plug for installation in the connector so that the cable can be energized even when the cable connector is disconnected. IH-A 24250 Insulating hood made of flexible rubber with outer conductive layer and an already installed insulating rod. To be mounted on the bushing in HDC-A 250 for insulation when a cable is temporary disconnected and remaining cables are under voltage. MA 250 Measurement adapter used for mega ohm measurements and to perform different measurements up to 5 kV DC, for example determination of phases.

KA 250 Transversal anchor bar. PSSK: for cables with Cu-wire screen, heat-shrink. PSSK E: for Ericssons cables with Al-wire screen, heat-shrink. TSH Branch seal kit

13

35

UKRA 90 Universal clamp.

Designation IP 250 IH-A 24250 MA 250 KA 250 PSSK 1 PSSL 1 L PSSK 1 E* PSSK 2 PSSL 2 L PSSK 2 E* TSH UKRA 90

Description Screened insulating plug Insulating hood Measurement adapter Busbar Screen separation kit, heat-shrink, for 3-core cable 1070 mm / 12 kV, 1035 mm / 24 kV Screen separation kit, heat-shrink, reinforced and extended, for 3-core cable, 1070 mm / 12 kV, 1035 mm / 24 kV Screen separation kit, heat-shrink, for 3-core Ericsson cable 1070 mm / 12 kV, 1035 mm / 24 kV Screen separation kit, heat-shrink, for 3-core cable 95300 mm / 12 kV, 50300 mm / 24 kV Screen separation kit, heat-shrink, reinforced and extended, for 3-core cable, 95300 mm / 12 kV, 50300 mm / 24 kV Screen separation kit, heat-shrink, for 3-core Ericsson cable 95300 mm / 12 kV, 50300 mm / 24 kV Branch seal Clamp for fixing cables

Qty kit 1 3 1 1 1 1 1 1 1 1 1 1

Weight kg/unit 0.8 2.3 0.3 0.5 1.9 3.3 1.9 2.5 3.9 2.5 0.31.0 0.23

See page 3/42 3/42 3/42 3/42 3/45 3/45 3/45 3/45 3/45 3/45 3/46 7/2

* Special screen separation for Ericssons 3-core cable with Al-wire screen.

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/42

Cable cabinet, 630 A HDC-A 1236 kV

Use For jointing or branching of XLPE- and EPR-insulated, 1236 kV 1-core or 3-core cables with conductor cross sections 25630 mm, 630 A. Up to four cables can be connected in parallel.

3
When branching in a cable grid, a branching point may be necessary to enable selected cable runs to be sectionalized during maintenance. With HDC-A a solution is provided that makes this possible. Standard The cable cabinet meets the requirements for mechanical impact testing according to IEC 60439-5. The cable connectors meet the electrical requirements according to CENELEC, HD 629.1 S2.
522 mm

The screened separable cable connectors are connected with coupling pieces pre-mounted in the cabinet. The cable cabinet is supplied with: 6 screened separable cable connectors Locks and padlock shackle Required when connecting more cables: 6 screened separable cable connectors type CSE-A. Parallel coupling piece type PC. Note: For 3-core cables, branch seal kit type TSH or screen separation kit type PSSK must be used. To be ordered separately. For foundation kit for floor installation, contact us.
Voltage kV 12 12 12 24 24 24 36 36 36 Insulation diameter mm 1320 18.530.5 30.545 1724 22.535 30.545 24.534 27.542 3855 Conductor cross section mm 2570 95300 400630 2570 95300 400630 5095 95300 400630

Overall height 1293 mm Height above ground level,993 mm

Design The enclosure is made of hot-dip-galvanized sheet steel plates with a foundation base plate and additional corrosion protection on parts that will be buried under ground.

996 mm

The third cable connector is to be ordered separately.

Always select products by Insulation diameter.

Designation basic configuration HDC-A 12630-01 HDC-A 12630-02 HDC-A 12630-03 HDC-A 24630-01 HDC-A 24630-02 HDC-A 24630-03 HDC-A 36630-01 HDC-A 36630-02 HDC-A 36630-03

Weight kg /unit 140 140 140 140 140 140 140 140 140

3/43 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Accessories, to be ordered separately Cable cabinet, HDC-A 1236 kV, 630 A

PG 630 Bushing for voltage testing of the cable. Adapted to cable connectors 1224 kV.

3
CSE-A IH-A 24630, IH-A 42630 Screened separable connector 630 A Insulating sealing hood of flexible for connection of an external cable. rubber with outer conductive layer and an already installed insulating hood. To be installed in HDC-A 630 instead of cable connector in order to temporarily insulate 630 A switchgear or transformer bushings. PSSK L Screen separation kit for 3-core cables with Cu-wire screen including heat-shrink branch seal and 2 meters long protective hoses.

PG-A 630 Bushing for voltage testing of the cable. Adapted to cable connectors 36 kV.

PC 630-3 Parallel coupling piece. Replaces the plug in CSE-A when making a parallel connection to another CSE-A 1224 kV.

IP 630 Screened insulating plug for installation in the screened separable connector so that the cable can be energized even when the connector is disconnected from the switchgear or transformer.

MA-A 630 Measurement adapter used for mega ohm measurements and to perform different measurements up to 5 kV DC, for determination of phases. 13

TSH Branch seal kit.

35

PC 630-3 L Parallel coupling piece. Replaces the plug in CSE-A when making a parallel connection to another CSE-A 36 kV.

PC 630/250 Connector for connecting a CSE-A 250, in parallel with a previously mounted CSE-A 630. 3 pieces in the kit, tool is included.

UKRA 90 Universal clamp.

KA 630 Transversal anchor bar.

Designation CSE-A KA 630 IH-A 24630 IH-A 42630 PC 630-3 PC 630-3 L PG 630 PG-A 630 IP 630 MA-A 630 PC 630/250 PSSK 2, PSSK 2 L, PSSK 2 E PSSK 3, PSSK 3 L, PSSK 3 E TSH UKRA 90

Description Screened separable connector. Transversal anchor bar, add two when using 1-core cables Insulating sealing hood, 1224 kV Insulating sealing hood, 36 kV Parallel coupling piece, 630, 1224 kV Parallel coupling piece, 630, 36 kV Bushing for voltage testing of the cable, 1224 kV Bushing for voltage testing of the cable, 36 kV Insulating plug, 630 A Measurement adapter, 630 A Parallel coupling piece between CSE-A 630 and CSE-A 250 Screen separation for 3-core cable 95300 mm / 3642 kV Screen separation for 3-core cable 95300 mm / 3642 kV Branch seal Clamp for fixing cables

Qty. per kit 3 1 3 3 3 3 1 1 1 3 3 1 1 1 1

Weight kg/kit Olika 0.8 5.2 5.2 1.1 1.1 1.5 2.0 0.8 0.1 3.0 2.5 / 3.9 / 2.5 3.4 / 4.8 / 3.4 0.31.0 0.23

See page 3/44 3/44 3/44 3/44 3/44 3/44 3/44 3/44 3/44 3/44 3/44 3/45 3/45 3/46 7/2
3/44

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

Screen separation kit PSSK

Use For XLPE- and EPR-insulated 3-core cables with common Cu- or Al-wire screen. Used to prevent flashover between the phases in small spaces, for example in a switchgear bay. Used together with screened separable connector CSE-A, shrouded termination KAP or cable termination SOT. Standard Meets the requirements of EBR KJ 25:99.
PSSK

Design PSSK: Length 1.2 m for cable with Cu-wire screen. A copper stocking with a screen cross section of 25 mm is fitted on each phase and connected to the wire screens of the cable. A heat-shrink branch seal and protective hoses are used as an outer sheath. It can also be cut for shorter installation. PSSK E: Length 1.2 m for cable with Al-wire screen. A copper stocking with a screen cross section of 25 mm is fitted on each phase and connected to thee wire screens of the cable. A heat-shrink branch seal and protective hoses are used as an outer sheath. It can also be cut for shorter installation. PSSK L: Length 2 m for cable with Cu- or Al-wire screen. The extended variant in heat-shrink when the branch area might be placed below ground. To achieve watertightness; mastic, vulcanizing tape and protective tape are applied to the lower part of the branch seal. Note! Cable connectors or cable terminations to be ordered separately.

Heat-shrink hose

Branch seal

PSSK with cable termination CSE-A.

Conductor cross section 12 kV 1095 95300 1095 95300 1070 95300 24 kV mm 1035 50300 1035 50300 1035 50300 50150 95300 50150 95300 5095 95300 95300 95300 5095 95300 36 kV 42 kV

Designation

Length L mm

Weight Kg/item 1.9 2.5 3.4 1.9 2.5 3.4 3.3 3.9 4.8
PSSK L with cable termination CSE-A. L

PSSK 1 PSSK 2 PSSK 3 PSSK 1 E PSSK 2 E PSSK 3 E PSSK 1 L PSSK 2 L PSSK 3 L

1200 1200 1200 1200 1200 1200 2000 2000 2000

3/45 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Branch seal kit TSH

Use TSH L are branch seal kits for sealing the 3-core cables branch when installing cable termination SOT, indoor or outdoor. SSH are kits with protective hoses to be used as additional extension of the branch seal together with TSH L. Design Branch seal and protective hoses of heat-shrink material as per below, lashing wire for mechanical reinforcement of the branch, earth wire and non-corrosive band-strip for connection of earth potential to termination. TSH 1 L and TSH 2 L include a branch seal and 3 protective hoses, length 1.2 m. SSH 1 L and SSH 2 L include only 3 heat-shrink protective hoses, length 1.2 m. SSH 1 S and SSH 2 S include only 3 heat-shrink hoses, length 0.4 m.

Designation

Outer diameter cable Min mm Max 60 60 110 110

Core diameter Min mm 9 9 16 16 9 9 16 16 27 27 50 50 27 27 50 50 Max

Cable cross section 12 kV mm 1095 1095 120300 120300 1095 1095 120300 120300 1050 1050 70300 70300 1050 1050 70300 70300 50240 50240 50240 50240 24 kV 36 kV

Length m Approx. 1.25 Approx. 0.45 Approx. 1.25 Approx. 0.45 1.2 0.4 1.2 0.4

Weight kg/kit 0.5 0.3 1.0 0.7 0.4 0.1 0.6 0.2

TSH 1 L TSH 1 S TSH 2 L TSH 2 S SSH 1 L SSH 1 S SSH 2 L SSH 2 S

22 22 47 47

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/46

Earthing kit for cable terminations JXT 13 and JSA 46

Earthing kits for XLPE- and EPR-insulated cables with earth screen of Cu-tape or Al-foil. The kits are designed for Kabeldon cable terminations and cable connectors. There is enough material in the kits for three 1-core cable terminations. There are also complete kits for 1-core cables.

Cu-tape screen

Al-foil

Cable Screen mm Earthing kit Cable accessories SOT 241 SOT 242 SOT 242 B SOT 243 SOT 244 SOT 245 SOT 246 SOT 361 SOT 362 CSS-A 12250-01 CSS-A 12250-02 CSS-A 24250-01 CSS-A 24250-02 CSE-A 12250-01 CSE-A 12250-02 CSE-A 24250-01 CSE-A 24250-02 CSE-A 12400-01 CSE-A 12400-02 CSE-A 24400-01 CSE-A 24400-02 CSE-A 12630-01 CSE-A 12630-02 CSE-A 12630-03 CSE-A 24630-01 CSE-A 24630-02 CSE-A 24630-03 CSE-A 36400-01 CSE-A 36400-02 CSE-A 36630-01 CSE-A 36630-02 CSE-A 36630-03 CSE-A 42400-01 CSE-A 42400-02 CSE-A 42630-01 CSE-A 42630-02 CSE-A 42630-03 KAP 630-1 SCL 3 KAP 630-2 SCL 5 APIT 4 APIT 5 APIT 6 APIT 7 APIT 8 APIT 9 APIT 10 APIT 11 APIT 12 APIT 13 APSEA xx1 APSEA xx2 APSEA XX3 APSEA XX4 APSEA XX5 APSEA XX6 APSEA XX7 APSEA XX8 APSEA XX9 APSEA XX10

For cables with Cu-tape screen 15 25 20 30 31 50 JXT 1 JXT 2 JXT 3 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

For cables with Al-foil screen 20-30 25-40 20 30 JSA 4 JSA 5 JSA 6 IV-tape IV-tape Shrink sleeve X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

For cables with Cu-tape screen JXT 13 contains copper stockings which are connected to the screen with constant force springs. For cables with aluminium foil screen JSA 46 contains copper braids which are connected to the screen with a plate and constant force springs. Note: If the cable has only Cu-wire screen, no earthing kit is needed. For cables with other screen types, or 3-core cable with Cu-tape screen, contact us for information.

X X

X X X X X

X X X X X X X

X X X X X

3/47 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Screen connection for cable joints JSA 1016

Screen connection kits for XLPE- and EPR-insulated cables with earth screen of copper tape or aluminium foil. The kits are designed for Kabeldon cable joints type SOJ and SMXB. There is enough material in the kits for one 3-core joint or three 1-core joints. Cables with copper tape screen JSA 1013 contains copper stockings which are connected to the screen with constant force springs. Connections to armouring (if any) are made with lashing wire. Cables with aluminium foil screen JSA 1416 contains copper braids which are connected to the screen with a plate and constant force springs. Note: If the cable has only copper wire screen, no earthing kit is needed. For cables with other screen types, or 3-core cables with Cu-tape screen, contact us for information.

Armouring

Copper tape screen

Aluminium foil

Cable Insulation diameter in mm Earthing kit for 1-core Earthing kit for 3-core Cable joint SOJ 121 SOJ 122 SOJ 123 SOJ 124 SOJ 125 SOJ 241 SOJ 242 SOJ 243 SOJ 244 SOJ 361 SOJ 362 SOJ 363 SOJ 364 SOJ 365 SMXB 1 SMXB 2 SMXB 3 SMXB 4 SMXB 5 SMXB 6 SMXB 7 SMXB 8 SMXB 9 SMXB 10 SMXB 11

For cables with copper tape screen 17 20 19 27 25 35 31 48 JSA 10-1 JSA 11-1 JSA 12-1 JSA 13-1 JSA 10-3 JSA 113 JSA 12-3 JSA 13-3 X X X X X X X X X X X X X X X X X X X X X X X X X

For cables with aluminium foil screen 19 27 25 35 31 48 JSA 14-1 JSA 15-1 JSA 16-1 JSA 14-3 JSA 15-3 JSA 16-3

X X X X X X X X X X X X X X X X X X X X X X X

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/48

Armouring kit for cable joints ARM

Use For restoring a steel wire or steel tape armoured cable. ARM can be used with SOJ and SMXB joints, as well as other joints.

Selecting ARM for unknown application requires the length of joint L and diameter over joint as below.
(mm) 140 1 2 3 4

3
100

60 500 1000 L (mm)

Design The kit consists of plastic mesh, spiral, funnel with holder, transparent tape and cast resin. The mesh and spiral are placed over the joint and sealed with the tape. The cast resin, which contains a base and hardener in a partitioned bag, is mixed and poured into the funnel until the mesh is full. The maximum storage temperature for the cast resin is 30 C.

ARM kit size L E.g. 115 and L 850 mm give ARM 3.

Kabeldon cable joints type SOJ and SMXB are completed with ARM as following
Cable joint SOJ 1213 SOJ 122-3 SOJ 123-3 SOJ 124-3 SOJ 2413 SOJ 242-3 SOJ 243-3 SMXB 13 SMXB 2-3 SMXB 3-3 SMXB 4-3 SMXB 5-3 SMXB 6-3 SMXB 7-3 SMXB 8-3 X X X X X X X X X X X ARM 1 X X X X ARM 2 ARM 3

Designation ARM ARM ARM ARM 1 2 3 4

Weight kg/item 3.5 6.5 8.0 10.0

3/49 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Cable connection Overhead line clamps

50

28

72

40

50 28 72 40

131

23,5 38 FK 120 Overhead line clamp. A greased tin-plate must be used when connecting to a Cu conductor outdoors. FK 300 Overhead line clamp. A greased tin-plate must be used when connecting to a Cu conductor outdoors.

FKFB Bracket to connect overhead line clamp FK to surge arrester.

Designation

Conductor Al or Cu size mm max mm 13 21

Tightening torque

Overhead line Al size mm max mm 512 1020.5

Weight kg/item 0.5 0.9 0.1

FK 120 FK 300 FKFB

50120 50300

25 Nm 25 Nm when 50100 mm 45 Nm when 100300 mm

3199 62234

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/50

Cable connection Cable lugs and connectors

B A E C

3
D

C SCL-B Bolt cable lug for cable terminations, type SOT, APIT and APSEA. For indoor and outdoor connection of both Cu- and Al-conductors. A greased cupal washer must be used when connecting to a Cu conductor outdoors. Meets the requirements of EN 61238-1. The cable lug is manufactured in an aluminium alloy surface-treated with tin. Shear-off bolts are made of brass. Breaks off once the correct torque is reached. Thanks to its design, the bolts will always break off directly at the edge of the cable lug. Single core kits The kit also includes: Adapter rings for different conductor cross sections. Covers used as protection over the bolts. SH-SKRM Bolt connector with partition and shear-off bolts for Al- and Cu-conductors. Meets the requirements of IEC 61238-1. The connector is equipped with turnable twosided shear-off bolts and a specially designed nut. The bolt is rotated in the appropriate direction, and the nut is then assembled. When the specified torque is reached, the bolt will shear off and the installation is completed. Single core kits. CW 3013, CW 3817 Cupal washer, to be used when connecting cable lug SCL-B to a copper busbar outdoors. The washers are coated with contact grease. Supplied in bags of three.

Designation

Conductor cross section Al / Cu Round mm Sector shaped mm 5095 35120 50185 95240 max mm 13 16 20 24 33

Tightening torque Nm 251) 25


1)

Dimensions A 58 74 100 101 165 B 70 91 115 120 180 C mm 24 28 33 38 50 13 13 13 16.5 16.5 24 28 33 38 50 D() E()

Weight kg/unit 0.10 0.25 0.30 0.35 0.90

SCL-B 95-12 SCL-B 150-12 SCL-B 240-12 SCL-B 300-16 SCL-B 630-16

1095 25150 50240 703002) 3006303)

361) 52 1) 801)

1) The bolt will be sheared-off at the right tightenening torque. 2) Solid round conductor up to 400 mm 3) Solid round conductor up to 800 mm

Designation

Conductor cross section Al / Cu Round stranded Solid round mm 11 16 20 25.5 33 Hole diameter mm 13 17 Sector shaped 2570 95 120185 240 Thickness mm 2 2

Tightening torque

Dimensions A 100 114 144 175 210 B mm C

Weight kg/unit

SH-SKRM 70 SH-SKRM 150 SH-SKRM 240 SH-SKRM 400 SH-SKRM 630 Designation CW 3013 CW 3817

1670 95150 185240 300400 500630 Outer diameter mm 30 38

15 20 30 40 45 Weight g/unit 5 8

21.5 27 33.5 41.5 49

0.25 0.35 0.60 0.90 1.20

3/51 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 12-42 kV

Accessories Bird protection

Use Used for bird protection on the high-voltage bushings for pole-mounted transformers. To prevent short-circuits caused by larger birds, HU is also placed on the surge arresters. For total protection, HU should be combined with an insulated down-conductor. This is done with insulation spiral HUS. On post insulators, HU is used in combination with two wings HUF. This will protect the overhead line closest to the insulator from short-circuiting. Standards HU is designed for bushings with a diameter of 120-220 mm according to DIN 42531 standard. Design All components are made of UV-resistant plastic.

HU 200 HUF

HUS

HU 150

Designation

Bushing diameter A min mm max

Pieces/kit

Length m

Weight kg/item 0.6 0.8 1.1 1.8

HU 150 HU 200 HUF HUS

120 160

160 220

3 3 6 1

0.6 30

Cable accessories for XLPE-insulated cables 12-42 kV | Kabeldon cable accessories 1420 kV |

3/52

4/1 | Kabeldon cable accessories 1420 kV | Cable accessories for PILC-insulated cables 12-52 kV

Table of contents Cable accessories for paper-insulated cables (PILC), 1252 kV

Cable accessories for PILC cables 1252 kV Cable termination, indoor for paper-insulated cable, OTIA 12 kV Cable joint and repair cable joint for paper-insulated cable, SMTD 12 kV Transition cable joint for paper-insulated cable, SMTXB 12 kV Transition cable joint, SMTXD 2436 kV Cable joint for paper-insulated cable, SMTA and SMTPA 2452 kV Dimensional drawings, SMT Spring-loaded gaskets for paper-insulated cables, FPA, FP, FPMP Accessories for paper-insulated cable joints and transition joints 4/3 4/5 4/7 4/8 4/9 4/10 4/11 4/12

Cable accessories for PILC-insulated cables 12-52 kV | Kabeldon cable accessories 1420 kV |

4/2

Cable termination, indoor, for paper-insulated cable (PILC) OTIA 12 kV

Use Indoor termination for paper-insulated 3-core cables 12 kV. Standard Meets the requirements of: SEN 24 14 34 Rated pressure 0,3 MPa (overpressure) Design The housing is made of cross-linked HD-polyethylene (XLPE) with a transparent lower part so that the oil level can be seen. A spring-loaded gasket type FPA provides a seal between cable and housing, as well as electrical contact between cable screen and housing. A GEX expansion vessel can be connected to the filling opening for the oil. The paper-insulated cable is jointed in the upper part of the housing to a flexible connecting cable. The length is 900 mm and must be compressed with the Elpress crimping system. As an alternative, bolt connection is available for Cu conductors of certain cross sections.

Designation

Conductor cross section Al mm Cu 25240

Suitable spring loaded gasket

Weight
min 120 (free air gap)

kg/item FPA 4.1

OTIA 152

35240

min 100

min 30

min 650

135

112

GEX 01 Expansion vessel for one OTIA 152.

GEX 02 Expansion vessel for two OTIA 152.

OTIA 152

4/3 | Kabeldon cable accessories 1420 kV | Cable accessories for PILC-insulated cables 12-52 kV

Accessories, to be ordered separately OTIA 12 kV

GEX

AK-ASA, K-ASA, K-ASB

SCL-B

FPA

Designation GEX SCL-B FPA

Description Expansion vessel Cable lug Spring-loaded gasket

See page 4/4 4/4 3/51 4/11

AK-ASA, K-ASA, K-ASB Connecting cable

Designation GEX 01 GEX 02

For use with One OTIA Two OTIA

Weight kg/item 2.0 2.0

Flexible connecting cable. Each kit contains one connecting cable (length 900 mm)
Beteckning Conductor cross section Al mm Press type connecting cable AK-ASA 3535-9 AK-ASA 5035-9 AK-ASA 7035-9 AK-ASA 95150-9 AK-ASA 120150-9 AK-ASA 150150-9 AK-ASA 185150-9 AK-ASA 240150-9 K-ASA 185150-9 K-ASA 240150-9 Bolt type connecting cable K-ASB 7035-9 K-ASB 150150-9 3570 95150 35 150 6.2 16.6 500 500 0.8 1.2 35 50 70 95 120 150 185 240 185 240 35 35 35 150 150 150 150 150 150 150 6.2 6.2 6.2 16.6 16.6 16.6 16.6 26.1 26.1 26.1 200 200 200 350 350 350 350 500 500 500 0.6 0.6 0.6 1.2 1.2 1.2 1.2 1.8 1.8 1.8 Cu Cross section of connecting conductor Cu flexible mm Max short-circuit current kA Max continuous rating A Weight kg/item

Cable accessories for PILC-insulated cables 12-52 kV | Kabeldon cable accessories 1420 kV |

4/4

Cable joint and repair cable joint for paper-insulated cable (PILC) SMTD 12 kV

Use For jointing paper-insulated 3-core lead-sheathed cables with Al or Cu conductor 12 kV. Standards Meets the requirements of: SEN 24 14 34 SEN 24 14 23 VDE 0278 Rated pressure 0.3 MPa (overpressure) Design The joint tube is a plastic-coated steel tube. The joint insulation consists of transparent polyester film and insulating oil. The oil prevents discharges in the paper-insulated cable. Spring-loaded gaskets provide a seal between the cable and the joint tube, as well as electrical contact between cable screens and joint tube. Type FPA or FP for belted cables and FPMP for separately lead-sheathed cables. The length of the SMTD 152 LK and SMTD 153 K joint tube allows crossing of the conductors, in order to obtain the right phase sequence. The repair joint SMTD 152 RK should be completed with three extension cores of paperor XLPE-insulated cable (not included). Note: Insulating bitumen compound and insulating oil need not be heated at temperatures exceeding +10C.

Maximum Conductor cross section Designation Al/Cu mm 3x240 3x240 3x300 3x240 SMTD 152 K SMTD 152 LK* SMTD 153 K SMTD 152 RK**

Type

Suitable spring-loaded gasket

Joint tube mm

Weight kg/item 25 27 52 39

Standard Extended Standard Repair

FPA FPA FP, FPMP FPA

100 100 150 100

* Extended type, allows crossing of the conductors, in order to obtain the right phase sequence. ** For jointing with XLPE-insulated cable, three insulating materials type IG 1718 must be added.

Accessories, to be ordered separately

FPA, FP, FPMP

SH-SKRM

Designation FPA, FP, FPMP SH-SKRM

Description Spring loaded gasket Bolt connector

Required Qty. 2 3*

See page 4/11 3/51

* 6 connectors should be used for SMTD 152 RK.

4/5 | Kabeldon cable accessories 1420 kV | Cable accessories for PILC-insulated cables 12-52 kV

Supplementary kit for SMTD For conversion to a transition joint

PXS

PXSA

A. Select the basic kit, SMTD joint (see previous page) and spring-loaded gasket according to the dimension of the paper-insulated cable. B. Select an XLPE-kit, PXS or PXSA, in accordance with the following table.

Cable insulation diameter

Conductor cross section mm 10240 10300 1035 50185 50185 240 240 240300

Designation

Type of termination for XLPE-insulated cable

Joint tube mm

Weight kg/item 2.9 5.5 2.6 2.6 2.6 2.7 2.7 5.2

32 32 1115 1526 1526 2532 2532 2532

PXS 02 PXS 03 PXSA 12 A PXSA 12 PXSA 12 W* PXSA 22 PXSA 22 W* PXSA 23

Tape Tape SOT termination SOT termination SOT termination SOT termination SOT termination SOT termination

100 150 100 100 100 100 100 150

* For 3 x 1-core XLPE-insulated cables with Al foil screen.

Accessories, to be ordered separately

SH-SKRM

Designation SH-SKRM

Description Connector with a partition

Required number 3

See page 3/51

Cable accessories for PILC-insulated cables 12-52 kV | Kabeldon cable accessories 1420 kV |

4/6

Transition cable joint for paper-insulated cable SMTXB 12 kV

Use For jointing a paper-insulated 3-core cable with an XLPEinsulated 1- or 3-core cable with Al or Cu conductor 12 kV. Standards Meets the requirements of: SEN 24 14 34 VDE 0278

Rated pressure 0,3 MPa (overpressure) Design The joint tube is a plastic-coated steel tube. The joint insulation consists of transparent polyester film and insulating oil. The oil prevents discharges in the paper-insulated cable. A crutch seal provides a seal between the steel joint tube and the XLPE-insulated cable, which is also covered with either a premolded termination (SOT) or silicone tape. Spring-loaded gaskets provide a seal between the cable and the joint tube, as well as electrical contact between cable
Insulation diameter mm 32 32 32 1526 1526 1526 2532 2532 2532 2532 50185 50185 50185 240 240 240 240300 Conductor cross section XLPE-insulated cable PXSA mm 10240 10240 10300 PXS Conductor cross section paper-insulated gasket cable maximum mm 240 240 300 240 240 240 240 240 240 300 SMTXB 1502 SMTXB 1502 L* SMTXB 1503 SMTXB 1522 SMTXB 1522 L* SMTXB 1522 W** SMTXB 1532 SMTXB 1532 L* SMTXB 1532 W** SMTXB 1533 FPA FPA FP, FPMP FPA FPA FPA FPA FPA FPA FP, FPMP Designation Suitable spring-loaded gasket Tube mm 100 100 150 100 100 100 100 100 100 150 kg/item 28 30 57 28 30 28 28 30 28 57 Weight

screen and joint tube. Type FPA or FP for belted cables and FPMP for separately lead-sheathed cables. A sealing ring for three 1-core cable is included in the kit. Note: Insulating bitumen compound and insulating oil need not be heated at temperatures exceeding +10C.

* L = Extended type, allows crossing of the conductors, in order to obtain the right phase sequence. ** For 3 x 1-core XLPE-insulated cables with Al foil screen.

Accessories, to be ordered separately

Options

FPA, FP, FPMP

SH-SKRM

GC

Designation FPA, FP, FPMP SH-SKRM

Description Spring-loaded gasket Connector with a partition

Required Qty. 1 3

See page 4/11 3/51

Designation

Steel tube Description internal mm

Qty.

See page

GC

100

Clamps for 3 x 1-core XLPEinsulated cables 40-45 mm

1 kit

4/12

4/7 | Kabeldon cable accessories 1420 kV | Cable accessories for PILC-insulated cables 12-52 kV

Transition cable joint SMTXD 2436 kV

Use For jointing a paper-insulated 3-core cable and XLPEinsulated 1-core or 3-core cable with Al or Cu conductor 2436 kV. Standards Meets the requirements of: SEN 24 14 34 VDE 0278 Rated pressure 0,3 MPa (overpressure) Design The joint tube is a plastic-coated steel tube. The insulation consists of impregnated crepe paper tape and insulating oil. The oil prevents discharges in the paper-insulated cable. The outer conductive layer of the cable is restored by conductive, impregnated crepe paper and copper net. A crutch seal provides a seal between the steel tube and the XLPE-insulated cable, which is also covered with an oil barrier of silicone tape. Spring-loaded gaskets provide a seal between the cable and the joint tube, as well as electrical contact between cable screens of PILC cable and joint tube. Type FP for belted cables and FPMP for separately lead-sheathed cables. A sealing ring for three 1-core cable is included in the kit. Note: Insulating bitumen compound and insulating oil need not be heated at temperatures exceeding +10C.

XLPE-insulated cable conductor cross section 12/20 (24) kV 10150 185240 300 18/30 (36) kV 1050 70150 240

PILC cable lead sheath Diameter mm 2085 2085 2085 Cross section mm 10300 10300 10300

Designation

Suitable spring-loaded gasket

Joint tube mm

Weight

mm

kg/item 76 76 76

SMTXD 3613 SMTXD 3623 SMTXD 3633

FP, FPMP FP, FPMP FP, FPMP

150 150 150

Accessories, to be ordered separately

FPA, FP, FPMP

SH-SKRM

Designation FP and FPMP SH-SKRM

Description Spring-loaded gasket Connector with a partition

Required Qty. 1 3

See page 4/11 3/51

Cable accessories for PILC-insulated cables 12-52 kV | Kabeldon cable accessories 1420 kV |

4/8

Cable joint for paper-insulated cable (PILC) SMTA and SMTPA 24-52 kV

Use For jointing paper-insulated 3-core cables with Al or Cu conductor 24-52 kV. Standards Meets the requirements of: SEN 24 14 34 SEN 24 14 23

Rated pressure 0,3 MPa (overpressure) Design The joint tube is a plastic-coated steel tube. The insulation consists of impregnated crepe paper tape and insulating oil. The oil prevents discharges in the paper-insulated cable. The outer conductive layer of the cable is restored by conductive, impregnated crepe paper and copper net. Spring-loaded gaskets provide a seal between the cable and the joint tube, as well as electrical contact between cable screen and joint tube. Type FPA or FP for belted cables and FPMP for separately lead-sheathed cables. Note: Insulating bitumen compound and insulating oil need not be heated at temperatures exceeding +10C.

Diameter of cable lead sheath min mm For belted cable 12 20 63 85 max

Maximum conductor cross section Al/Cu 24 kV 36 kV mm 3x120 3x300 3x70 3x240 3x150 52 kV

Designation

Suitable spring-loaded gasket

Joint tube mm

Weight

kg/item 25 62

SMTA 24362 SMTPA 24523

FPA FP/FPMP

100 150

For belted and separate lead-sheathed cable

Accessories, to be ordered separately

FPA, FP, FPMP

SH-SKRM

Designation FPA, FP, FPMP SH-SKRM

Description Spring-loaded gasket Bolt connector

Required Qty. 2 3

See page 4/11 3/51

4/9 | Kabeldon cable accessories 1420 kV | Cable accessories for PILC-insulated cables 12-52 kV

Dimensional drawings SMTD, SMTXB, SMTXD, SMTA, SMTPA

A B

Designation A SMTXB 1502 SMTXB 1502 L* SMTXB 1503 SMTXB 1522 SMTXB 1522 L* SMTXB 1522 W** SMTXB 1532 SMTXB 1532 L* SMTXB 1532 W** SMTXB 1533 1135 1335 1500 1135 1335 1135 1135 1335 1135 1500

Dimensions in mm B 175 175 228 175 175 175 175 175 175 228 C 900 1100 1200 900 1100 900 900 1100 900 1200 D 100 100 150 100 100 100 100 100 100 150

Designation A SMTXD 3613 SMTXD 3623 SMTXD 3633 1500 1500 1500

Dimensions in mm B 228 228 228 C 1200 1200 1200 D 150 150 150

* L = Extended type, allows crossing of the conductors, in order to obtain the right phase sequence. ** For 3 x 1-core XLPE-insulated cables with Al foil screen.

A B

Designation A SMTD 152 K SMTD 152 LK SMTD 153 K SMTD 152 RK 1135 1335 1500 1935

Dimensions in mm B 175 175 228 175 C 900 1100 1200 1700 D 100 100 150 100

Designation A For belted cable SMTA 24362 SMTPA 24523 1335 1500

Dimensions in mm B 175 228 C 1100 1200 D 100 150

For belted or separate lead-sheathed cable

Cable accessories for PILC-insulated cables 12-52 kV | Kabeldon cable accessories 1420 kV |

4/10

Spring-loaded gaskets for paper-insulated cables (PILC) FPA, FP, FPMP

FPA 100 mm for belted cables.

FP 150 mm for belted cables.

FPMP 150 mm, 3-hole gasket,non-magnetic design for separate lead-sheathed cables.

Diameter over lead sheath mm 18-21 2124 2427 2730 3033 3336 3639 3942 4245 4548 4851 5154 5457 5760 6063 6366

Designation

Weight kg/item

Diameter over lead sheath mm 2530 3035 3540 4045 4550 5055 5560 6065 6570 7075 7580 8085

Designation

Weight kg/item

FPA 1021 FPA 1024 FPA 1027 FPA 1030 FPA 1033 FPA 1036 FPA 1039 FPA 1042 FPA 1045 FPA 1048 FPA 1051 FPA 1054 FPA 1057 FPA 1060 FPA 1063 FPA 1065

1.2 1.2 1.1 1.1 1.1 1.1 1.0 1.0 1.0 1.0 1.0 0.9 0.9 0.9 0.9 0.9

FP 1530 FP 1535 FP 1540 FP 1545 FP 1550 FP 1555 FP 1560 FP 1565 FP 1570 FP 1575 FP 1580 FP 1585

4.2 4.2 4.3 4.1 4.2 3.9 4.1 4.0 3.9 3.8 3.9 4.0

Diameter over lead sheath mm 2023 2326 2629 2932 3235 3538 3840

Designation

Weight kg/item

FPMP 1523 FPMP 1526 FPMP 1529 FPMP 1532 FPMP 1535 FPMP 1538 FPMP 1540

4.5 4.4 4.4 4.4 4.2 4.1 4.2

4/11 | Kabeldon cable accessories 1420 kV | Cable accessories for PILC-insulated cables 12-52 kV

Accessories Cable joints for PILC and transition joints

4
GC The kit contains one sealing ring, bolts and two roomy clamp halves for 100 mm joint tubes. The clamps are made from fiberglass reinforced polymer. The bolt and washer are molded into the material. Used on the XLPE side of the transition joint; SMTXB 1502/1522/1532 when installing 1-core cables with an outer diameter greater than 40 mm. IA 2502 - 2519 Bituminized paper for filling, for example in cable clamps. RKM 402 Funnel for oil filling.

IA 1003 Stress grading tape.

IA 2112 - 2113 Impregnated crepe paper tape.

IKP Impregnated carbon crepe paper (conductive).

Designation GC IA 2502 IA 2508 IA 2518 IA 2519 RKM 402 IA 1003 IA 2112 IA 2113 IKP

Use SMTXB with 100 joint tube For filling cable clamps For filling cable clamps For filling cable clamps For filling cable clamps For oil filling Paper-insulated cable joint Paper-insulated cable joint Paper-insulated cable joint

Length m Cable 40-45 3 14 10 14 9 9

Width mm 83 200 83 100 10 24

Thickness mm 0.5 0.5 0.5 0.5

Weight kg/item 0.72 0.20 1.40 0.50 0.75 0.10 0.13 0.40 0.60 0.30

Cable accessories for PILC-insulated cables 12-52 kV | Kabeldon cable accessories 1420 kV |

4/12

Accessories Cable joints for PILC and transition joints

IG 1201 Cold insulating bitumen compound for cable clamps.

IG 1601, IG 1604 Insulating oil, for joints and terminations for paper-insulated cables 12-52 kV. Need not be heated at temperatures exceeding +10C.

IG 1717, 1718 Insulating film made of transparent polyester for transition joints and for paper-insulated cables 1224 kV, type SMTXB and SMTD.

IK 1002 Linen yarn.

IK 1003 Polyester tape.

Designation IG 1201 IG 1601 IG 1604 IG 1717 IG 1718 IK 1002 IK 1003

Length m 1.7 1.5 5 4x1.5

Width mm 457 711 2.5

Volume l 1.0 4.0

Weight kg/item 1.3 1.0 4.1 0.3 0.2 0.2 0.1

4/13 | Kabeldon cable accessories 1420 kV | Cable accessories for PILC-insulated cables 12-52 kV

Cable accessories for PILC-insulated cables 12-52 kV | Kabeldon cable accessories 1420 kV |

4/14

5/1 | Kabeldon cable accessories 1420 kV | Other accessories and tools

Table of contents General accessories and tools, 1252 kV

General accessories and tools Other accessories, tapes Other accessories Tools 5/3 5/4 5/6

5 5

Other accessories and tools | Kabeldon cable accessories 1420 kV |

5/2

Other accessories Tapes

IA 2333 - 2338 Insulating vulcanizing tape.

IA 2339 Insulating vulcanizing tape.

IA 2342 Silicon rubber tape.

IA 2343 Silicon rubber tape.

5 5

IA 2352 Semiconducting tape.

IA 2362 Filling tape.

IA 2441 - 2444 Protective tape.

RULLE Two-layer insulating tape made of EPDM and butyl rubber.

IA 2421 Electrical tape.

Designation IA 2333 IA 2337 IA 2338 IA 2339 IA 2342 IA 2343 IA 2352 IA 2362 IA 2421 IA 2441 IA 2443 IA 2444 RULLE 1 RULLE 2

Length m 9 9 9 2 9 2.5 4.5 1.5 10 10 10 30.5 3.5 5.5

Width mm 38 19 38 25 25 25 19 38 19 25 50 50 60 60

Thickness mm 0.8 0.5 0.5 0.76 0.5 0.5 0.8 3.2 0.18 0.4 0.4 0.4 2.0 2.0

Weight kg/item 0.50 0.20 0.40 0.10 0.16 0.30 0.10 0.30 0.06 0.20 0.30 0.90 0.60 0.90

5/3 | Kabeldon cable accessories 1420 kV | Other accessories and tools

Other accessories

IK 1105, 1106, 1107, 1108, 1109 Abrasive cloth.

IK 1405, IK 1406 Lashing wire (tin-coated copper wire).

IK 1401, IK 1407 Lashing wire (tin-coated copper wire).

5 5

IK 2221 Silicone grease, 25 g.

IK 2233 Grease, type AP paste, 10 g.

IK 1502 Lashing wire (galvanized steel wire).

Designation IK 1105 IK 1106 IK 1107 IK 1108 IK 1109 IK 1405 IK 1406 IK 1401 IK 1407 IK 1502 IK 2221 IK 2233

Length m 1 1 1 1 1 5 9.5 2 6 4

Diameter mm 1.4 1.4 1.4 1.0 1.5

Coarseness 100 80 120 220 400

Weight kg/item 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.1 0.2 0.1 0.03 0.02

Other accessories and tools | Kabeldon cable accessories 1420 kV |

5/4

Other accessories

IA 1701 Earthing braid, sold by the metre, 10 mm.

IA 1706 Copper net for e.g. SMXB, sold by the metre, approx. 10 mm.

5 5

IK 2230 Washing cloth, 3 alcohol-soaked paper cloths 200 x 300 mm.

SKALUS Peeling string for XLPE-insulation.

MBR 250 Stainless marking tape, 100 units/kit.

Designation IA 1701 IA 1706 IK 2230 SKALUS MBR 250

Length m 2 0.25

Width mm 16 80

Thickness mm 1.0 1.0 1.0 1.0

Weight 0.10 kg/m 0.06 kg/m 0.03 kg/unit 0.02 kg/unit 0.50 kg/kit

5/5 | Kabeldon cable accessories 1420 kV | Other accessories and tools

Accessories Tools (all dimensions in mm)

350

285

730 R Torque wrench for bolt connectors, bolt cable lugs, overhead line clamps, etc. Supplied with 7 mm socket head, extension and 8 mm internal hexagon head. Torque range 6-50 Nm. 305

Intercable No. RKS 1607 054 Cable shears for cutting cable max 54 mm.

5 5
145

RKM 1055 Splitting tool for longitudinal splitting off XLPE-insulation with 10-55 mm.

RKM 670 Cable knife, 30 mm blade.

330

RKM 672 Sheath removing knife with two handles for plastic sheated cable.

RKM 1435 and RKM 2550 Brace for use in the assembly of the connectors and cable lugs with a torque or shear-off screw. Provides a secure and stable mounting. Adjustable between min and max diameter of the connector or cable lug. Available in two sizes according to the table. Meets the insulation requirements of EN/IEC 60900.

RKM SB Cordless impact wrench set to fit connectors and cable lugs with shear-off bolts. Meets the insulation requirements of EN/IEC 60900. The kit includes: Impact wrench Battery: 18 V/3.0Ah - 2 st Battery charger Allen nut: SW5, SW6, SW8

Designation 730 R RKM 1055 RKM 1055 K RKM 672 RKM 1435 RKM 2550 RKM 670 RKM SB

Description Torque wrench Splitting tool Spare blade for RKM 1055 Sheath removing knife Brace for bolted connector for outer diameter of 1435 mm Brace for bolted connector for outer diameter of 2550 mm Cable knife Cordless impact wrench set

RKS 1607 054 Cable shears

Other accessories and tools | Kabeldon cable accessories 1420 kV |

5/6

Accessories Tools (all dimensions in mm)

153 175

Intercable No. AV 6220 Sheath removing tool for PE-sheathed cable > 20 mm.

Model 1700 Series Peeling tool for strippable outer conductive layer on XLPE-insulated cable 13-51 mm.

177 235

Intercable No. FBS 1722 1 Stripping tool for the vulcanized, outer conducting layer of XLPE-insulated cable 10-52 mm. The tool is supplied in a rigid case with a tube of silicone grease.

GB-M20 Cutting tool for cable sheath and XLPE-insulation: Diameter: 15-50 mm Cutting depth: 8 mm

GB-M20 S8 Spare peeling blade to GB-M20. 5 per kit.

Designation AV 6220 Model 1700 Series FBS 1722 1 GB-M20 GB-M20 S8

Description Sheath removing tool Peeling tool Stripping tool XLPE stripping tool Spare blade for GB-M20 S8

5/7 | Kabeldon cable accessories 1420 kV | Other accessories and tools

Other accessories and tools | Kabeldon cable accessories 1420 kV |

5/8

6/1 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Table of contents Cable accessories 52420 kV

Introduction Cable accessories 52420 kV 6/3

Cable terminations Outdoor cable termination APED 3684 kV Outdoor flexible cable termination, APSEA 5272 kV Outdoor cable termination, APECB 84420 kV Dry outdoor pre-assembled cable termination, TD 145 kV Dry plug-in indoor cable termination, CD 145 kV for connection to: gas-insulated switchgear (GIS) transformers (TRF) Cable termination, APEGA 84420 kV for connection to: gas-insulated switchgear (GIS) transformers (TRF) Earthing kits for cable terminations, JSA, SCK 6/17 6/17 6/21 6/15 6/15 6/4 6/7 6/10 6/13

Cable joints Premolded one-piece cable joint without screen interruption JS 52123 kV with screen interruption JX 52123 kV Premolded one-piece cable joint without screen interruption JS 245 kV with screen interruption JX 245 kV Premolded cable joint without screen interruption SMPGB 145170 kV with screen interruption SMPGB-C 145170 kV Premolded cable joint without screen interruption SMPGB 420 kV with screen interruption SMPGB-C 420 kV Accessories, ARM, SKKB 6/31 6/31 6/33 6/28 6/28 6/26 6/26 6/22 6/22

Accessories Tools and oil 6/34

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/2

Introduction Cable accessories 52420 kV

ABB in Alingss has long experience in the area of 52420 kV and has always led the field in research and development. We were among the first in the world to use stress cone technology to control electrical fields. One reason for our success is that we have constantly developed cable accessories for all types of cables. This has given us an experience base that is both broad and deep. We have also developed our accessories to facilitate for optical fiber in power cables, and even integrated cross bonding in cable joints. This involves system designers to improve their systems. One feature that sets our range of cable accessories for this voltage range apart, is their modular design. This makes the

accessories exeptionally easy to install. The installers become familiar with the components, and this reduces the risk of mistakes. Another advantage is that our cable terminations can be assembled on the ground under controlled conditions and then lifted into place simple and safe! Unless otherwise specified, the cable accessories are supplied as standard with bolt connections for conductors. We offer training courses for installers and supervisors. For information, please contact your ABB-representative or our training department directly.

Installation of Kabeldon cable joint with screen interruption, JX 245.

Installation of composite cable termination, APECB.

Cable termination APEGA are installed in a gas-insulated switchgear.

Installation of dry cable termination, TD 145 kV.

We develop accessories for most cable designs, including cables with optical fiber.

6/3 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Outdoor cable termination APED 3684 kV

Use Suitable for installations in which the termination is to be used as a fixed connection point and for installations where there is a risk of very high continuous creepage currents. Standard Meets the requirements of: IEC 60840 IEEE 48 Design The cable termination consists of a porcelain or composite insulator installed on a box body made of Al casting. The eld control component is a premolded stress cone. The insulator has sheds of the short-long type and is lled with synthetic insulating oil. The porcelain insulator is available in brown. The composite insulator is available in grey. A post insulator kit which includes three stand-off insulators and a supporting plate is used for insulated installation.
APED 360 P top bolt

insulator synthetic insulating oil stress cone

6
box body

cable clamp

APED 521 B

A top bolt with a diameter of 30 mm is included in the kit. Installation Installation can be simplied by assembling the termination horizontally on the ground before lifting it into place.
APED 843 B APED 722 P

The following cable data should be stated when ordering: Voltage Diameter across prepared insulation Conductor cross section Conductor material Cu or Al Screen, cross section and type Outer diameter of the cable Insulator, porcelain 52 och 84 kV or composite 36 and 72 kV Top bolt with bolt connection as standard

Voltage

Insulation diameter min max mm 25 66

Cable outer sheath max mm 85

Max conductor cross section mm 1200

kV 1236, 52, 72, 84

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/4

Technical specification APED 3684 kV

30

Max. permissible forces acting on the top bolt, horizontally and vertically: 2000 N.

Max 35

18

Dimensions in mm

125

Creepage distance

202,5 182 234

Attachment to bracket for insulated installation Three 18 mm holes for M16 bolts.

280

52

14

There are two versions of insulators for APED 3684 kV: 52 and 84 kV with suffix B: Brown porcelain in traditional design. 36 and 72 kV with suffix P: Composite insulator with grey silicone rubber and a fiberglass reinforced epoxy, resin hollow core. Light-weight and less sensibility for outer damages.

76 32

Attachment to beam Three 14 mm hole for M10 bolts.

Voltage kV 52 84 1236 72

Insulator

Designation

Creepage distance min mm

Dimensions A mm 645 1040 570 950 267 267 270 270

Net weight kg/item 48 67 27 33

Porcelain Porcelain Composite Composite

APED 521 B APED 843 B APED 360 P APED 722 P

1340 2635 950 2330

6/5 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Applications and accessories APED 3684 kV

30

Inclination up to 30.

GAP-APED Rod gap.

Accessories, to be ordered separately

PIU-APED Post insulator kit for fixing to a supporting plate for insulated installation.

RE-APED-T Re-assembly kit for APED-T (for Insulation 25-48.1mm). Stress cone is included. Bolt clamp is to be ordered separately as required.

RE-APED-M Re-assembly kit for APED-M (for Insulation 48-66 mm). Stress cone is included. Bolt clamp is to be ordered separately as required.

Designation GAP-APED PIU-APED RE-APED-T RE-APED-M

Description Rod gap Post insulator kit Re-assembly kit Re-assembly kit

Use Protects against over-voltage. When insulated installation. Used for re-assembly of an already installed termination. Insulation 2548.1 mm. Used for re-assembly of an already installed termination. Insulation 466 mm.

Designation JSA SCK

Description Earthing kit for cable with metallic sheath, e.g. lead. Not needed if cable has only Cu-wire screen. Screen connection for Al-foil radial waterproof cable. Not needed if cable has only Cu-wire screen.

See page 6/21 6/21

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/6

Outdoor flexible cable termination APSEA 5272 kV

Use Flexible cable termination, suitable for installations in which the termination can be installed in any angle. The termination is not self-supporting. Standard Meets the requirements of: IEC 60840 Design The cable termination is made up of modules comprising a field controlling stress relief cone, sheds to increase the creepage distance and a top cap.

top bolt

creepage current electrode

top cap

sheds

The modules are made of proven weather and leakage current resistant rubber. The diameter across the prepared insulation is 33-66 mm. Installation The termination is installed easily, entirely without heat. The stress cone and sheds are to be pushed on to the cable and snapped together. The following cable data should be stated when ordering: Voltage Diameter across prepared insulation Conductor cross section Conductor material Cu or Al Screen, cross section and type Outer diameter of the cable Note: Top bolt or cable lug is to be ordered separately, see following pages.
33-66 mm

stress cone creepage current collector

APSEA 72

APSEA 52

6/7 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Technical specification and applications APSEA 5272 kV

30/40

Voltage level kV

Prepared insulation mm 3336 3639.5 39.543 4348 4854 5460 6066 3336 3639.5 39.543 4348 4854 5460 6066

Designation

Top cap type

Creepage distance min mm

Length A mm 580 580 580 580 580 650 650 690 690 690 690 870 870 870

Net weight kg/item 4 4 4 4 4 4 4 5 5 5 5 5 5 5

125

52 52 52 52 52
165

APSEA 521 U APSEA 522 U APSEA 523 U APSEA 524 U APSEA 525 U APSEA 526 U APSEA 527 U APSEA 721 U APSEA 722 U APSEA 723 U APSEA 724 U APSEA 725 U APSEA 726 U APSEA 727 U

THS THS THS THS THSA THSA THSA THS THS THS THS THSA THSA THSA

1150 1150 1150 1150 1150 1250 1250 1420 1420 1420 1420 1790 1790 1790

52 52 72 72 72 72 72 72 72

Creepage distance

Extension kits
Designation Extra creepage distance per kit mm APSEA 521 U / 721 U APSEA 522 U / 722 U APSEA 523 U / 723 U APSEA 524 U / 724 U APSEA 525 U / 725 U APSEA 526 U / 726 U APSEA 527 U / 727 U ~ 290 ~ 290 ~ 290 ~ 290 ~ 135 ~ 135 ~ 135 Extension kit Article number 6235.0163* 6235.0164* 6235.0165* 6235.0166* 6235.0167** 6235.0168** 6235.0169**

* The kit consists of 2 sheds and 1 adapter. ** The kit consists of 1 shed only.

180

Can be installed in any angle.

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/8

Accessories, to be ordered separately APSEA 5272 kV

Top caps, cable lugs and top bolts are supplied by the piece.

Top cap, THS, THSA A

The top cap THS or THSA is selected based on size of the cable termination and the outer diameter of thickest part of cable lug or top bolt. E.g. for top bolts and cable lugs see dimension B in the table below.

Top hole Max. diameter mm 30 40 50 65

Top cap

Top cap

THS THS THS THS

28 37 47 60

THSA THSA THSA THSA

28 37 47 60

Top bolts and cable lugs


Description Cable conductor Designation material
125

Cable cross section mm 120 150, 185 240 300, 400 500 630 800 1000 1200 120 150, 185 240 300, 400 500 630 800 1000 1200 1095 25150 50240 70300 300630

Diameter A mm 30 30 30 30 30 30 40 40 40 30 30 30 30 30 30 40 40 40 24 28 33 38 50 45 45 50 55 60 60 65 65 65 45 45 50 55 60 60 65 65 65 24 28 33 38 52 B

Net weight kg/item 0.5 0.5 0.8 0.8 0.9 0.9 1.2 1.2 1.1 1.6 1.6 2.4 2.4 2.8 2.8 4.0 3.8 3.5 0,10 0,25 0,30 0,35 0,90

B A/K-TBF SKR Top bolt. Moment 45 Nm.

A SCL-B Bolt cable lug.

Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Top bolt Cable lug Cable lug Cable lug Cable lug Cable lug

Al Al Al Al Al Al Al Al Al Cu Cu Cu Cu Cu Cu Cu Cu Cu Al/Cu Al/Cu Al/Cu Al/Cu Al/Cu

A-TBF 30 120 SKR A-TBF 30 185 SKR A-TBF 30 240 SKR A-TBF 30 400 SKR A-TBF 30 500 SKR A-TBF 30 630 SKR A-TBF 40 800 SKR A-TBF 40 1000 SKR A-TBF 40 1200 SKR K-TBF 30 120 SKR K-TBF 30 185 SKR K-TBF 30 240 SKR K-TBF 30 400 SKR K-TBF 30 500 SKR K-TBF 30 630 SKR K-TBF 40 800 SKR K-TBF 40 1000 SKR K-TBF 40 1200 SKR SCL-B 95-12 SCL-B 150-12 SCL-B 240-12 SCL-B 300-16 SCL-B 630-16

A/K-TBF SKR

SCL-B

Description A/K-TBF SKR SCL-B UKR JSA 1 SCK 2

Use Top bolt Cable lug, if needed. For fixing cables. Earthing kit for cable with metallic sheath, e.g. lead. Not needed if cable has only Cu-wire screen. Screen connection for Al-foil radial waterproof cable. Not needed if cable has only Cu-wire screen.

See page 6/9 3/51 7/2 6/21 6/21

UKR 90

6/9 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Outdoor cable termination APECB 84420 kV

Use For installations in which the termination is to be used as a fixed connection point and in installations where there is a risk of very high continuous creepage currents. Standard Meets the requirements of: IEC 60840, < 170 kV IEC 62067, 245420 kV IEEE 48 Design The cable termination consists of an insulator installed on a box body made of Al castings. The box body consists partly of insulating material, which provides an insulated installation. The base part must be installed on a bracket. For 420 kV a post-insulator kit PIU-APEC is included to provide insulated installation. The field control component is a premolded stress cone. The insulator has sheds of short-long type and is filled with synthetic insulating oil. The insulator is of grey silicone rubber and has a fiberglass reinforced epoxy resin hollow core. Is light-weight and less sensitive for outer damages. A bolt clamp in the top fitting is used to connect the conductor to the top bolt. Top bolt and bolt clamp are included in the kit. For the maximum permitted diameter across the oversheath of the cable and the diameter across prepared insulation, see the table below. Installation Installation can be simplified by assembling the termination horizontally on the ground before lifting it into place. When ordering, please state the following data: Voltage Diameter across prepared insulation Conductor cross section, diameter Screen, cross section and type Outer diameter of cable If optical fibres in screen Diameter and material of the top bolt, Al or Cu for connecting to overhead power line

top bolt Bolt clamp

Insulator synthetic insulating oil

6
stress cone

Base part Cable clamp

APECB 84 APECB 145 APECB 170

APECB 245 APECB 300 APECB 420

Voltage

Insulation diameter min max

Outer sheath mm

kV 170 245 300 420 45.5 73 73 80

mm 107 120 120 124

170 170 170 170

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/10

Technical specification APECB 84420 kV

Min 125

Max. permissible forces acting on the top bolt, horizontally and vertically: 2000 N.

18.5

Dimensions in mm

140

345-350

Creepage distance

Fixing to bracket for 84300 kV Insulated or non-insulated: four 18 mm holes for M16 bolts.

345-350 min 280

22

150

495

6
C Fixing to bracket for 420 kV Non-insulated: four 18 mm holes for M16 bolts. Insulated: four 22 mm holes for M20 bolts. 495 min 350

Voltage kV 84 145 170 170 170 245 300 420

Insulator

Designation* A

Dimensions B mm 40/50/54/60 40/50/54/60 40/50/54/60 40/50/54/60 40/50/54/60 40/50/54/60 40/50/54/60 40/50/54/60 C 359 359 359 359 359 490 490 600 D 235 235 235 235 235 235 235 395

Creepage distance min mm 2820 3750 4500 5950 8000 9360 9360 14900

Net weight kg/item 100 105 110 120 135 290 290 600

Composite Composite Composite Composite Composite Composite Composite Composite

APECB 841 P APECB 1452 P APECB 1703 P APECB 1704 P APECB 1705 P APECB 2456 P APECB 3006 P APECB 4201 P

1320 1620 1820 2140 2720 3030 3030 4600

* When the cable diameter is larger than 120 mm, add: 170 at the end of the designation (e.g. APECB 841 P 170).

6/11 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Applications and accessories APECB 84420 kV

30

6
Inclination up to 30. GAP-APECB Rod gap. PIU-APEC Post insulator kit for fixing APECB 420 kV when insulated installation. Included in the kit.

Accessories, to be ordered separately

~ 500

OKT Optical fiber kit for cables with integrated optical fibers in the earth screen.

RE-APECB Re-assembly kit. Stress cone is included. Bolt clamp must be ordered separately.

SV140, SV190, SV 215 Tools for installation of stress cones as follows: SV 140 for SKG SV 190 for SKGB SV 215 for SKGE

Designation GAP-APECB PIU-APEC OKT RE-APECB SV 140 SV 190 SV 215 Designation JSA* SCK*

Description Rod gap for protection against over-voltage 84-170 kV Post-insulator kit for fixing APECB 420 kV when insulated installation Optical fiber kit for optical fibers in the screen of the cable 84420 kV Re-assembly kits for re-assembling of already installed cable terminations Installation tool for stress cone, SKG for cable termination APECB 84170 Installation tool for stress cone, SKGB for cable termination APECB 245300 Installation tool for stress cone, SKGE for cable termination APECB 420 Description Earthing kit for cable with metallic sheath, e.g. lead. Not needed if cable has only Cu-wire screen. Screen connection for Al-foil radial waterproof cable. Not needed if cable has only Cu-wire screen. See page 6/21 6/21

* NB: if earthing kit is required, this increases the cable outer diameter by 20 mm.

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/12

Dry pre-assembled cable termination, outdoor TD 145 kV

Use For installations in which the cable termination is to be used as a fixed connection point and in installations where there is a risk of very high continuous creepage currents. Standard Meets the requirements of: IEC 60840 Design TD 145 contains of: a pre-assembled cable termination, top bolt and bolt clamp in the top fitting and also cable clamp and earth clamp.

top bolt bolt clamp

The cable termination consists of a composite insulator with integrated base part, stress cone, support pipe and dry electrical insulating silicone compound. Both the support pipe and the cable clamp are made of fiberglass reinforced polyester that provides an insulated installation. The field control component is a premolded stress cone. The termination has a minimum creepage distance of 4650 mm, which means it fulfills Pollution class IV according to IEC 60815-3. A bolt clamp for the cable conductor and a top bolt is included in the kit. For the maximum permitted diameter across the oversheath of the cable and the diameter across prepared insulation, see the table below. Installation The termination comes pre-assembled from the factory which remarkably reduces installation time after cable preparation. Installation can be made horizontally or vertically. No filling of insulating medium at site. When ordering, please state the following data: Diameter across prepared insulation Conductor cross section Screen, cross section and type Outer diameter of cable If optical fibres in screen Diameter and material of the top bolt, Cu or Al for connecting to overhead power line
Insulation diameter min mm 53 102 max
Base part

Outer sheath max mm 150

Max conductor cross section mm 2500

Voltage kV 145

Insulator

Designation

Creepage distance min mm 4650

Prefabricated cable termination cable clamp earth clamp

Net weight kg/item 100

Composite

TD 145

6/13 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Technical specification, applications and accessories TD 145 kV

40/50/54/60

~ 130 mm

Max. permissible forces acting on the top bolt, horizontally and vertically: 2000 N.

18.5

Dimensions in mm

140

345-350

Creepage distance min 4650 mm

345-350 min 280

Fixing to bracket Insulated or non-insulated: four 18.5 mm holes for M16 bolts.

1630 mm

45

380 mm

325 mm

Accessories, to be ordered separately

Inclination up to 45.

Selection table for installation cone


Inner diameter
RKM 145 Installation tool. Opto kit

Outer diameter mm 53 55 58 61 64 67 70 73 78 84 93 102 105

Installation cone Article number 4209.2384 4209.2385 4209.2386 4209.2387 4209.2388 4209.2331 4209.2332 4209.2333 4209.2334 4209.2335 4209.2336 4209.2337 4209.2400

Optical fiber kit for cables with


integrated optical fibers in the earth screen.

Installation cone.

Designation RKM 145 Installation cone Opto kit

Description Installation tool Installation cone, see table. Optical fiber kit for optical fibers in the screen of the cable

kV 20 22 22 29 38 28 32 36 43 48 51 57 57

Designation JSA SCK

Description Earthing kit for cable with metallic sheath, e.g. lead. Not needed if cable has only Cu-wire screen. Screen connection for Al-foil radial waterproof cable. Not needed if cable has only Cu-wire screen.

See page 6/21 6/21

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/14

Dry plug-in cable termination CD 145 kV

Use Dry cable termination suitable as a fixed connection point in a gas-insulated switchgear, a transformer without a separate cable box or where the cable box is filled with transformer oil. Standard Meets the requirements of: IEC 60840 Design The cable termination is to be ordered in two separate kits: 1. CD 145; plug-in connector kit consisting of plug-in connector, locking halves, stress cone, pre-loaded spring assembly, box body, earth clamp and cable clamp. 2. CDI 145; insulator kit consisting of top fitting, epoxy insulator with integrated screen separation and pressure ring. For the maximum permitted diameter across the oversheath of the cable and the diameter across prepared insulation, see the table below. The following cable data should be stated when ordering: Voltage Diameter across prepared insulation Conductor cross section Conductor material, Cu or Al Screen, cross section and type Outer diameter of the cable If optical fibres in screen Type of connector: Plug-in connector as standard
pressure ring

top fitting

plug-in connector

locking halves epoxy insulator stress relief cone

spring assembly

box body

earth clamp

cable clamp

2. CDI 145, Insulator kit.

Insulation diameter min max mm 44 96

Conductor Cu/Al mm 3002000

Outer sheath CUW PAL, MET mm 150 130

Voltage level kV
145 145

Designation
CD 145 CDI 145

Description
Plug-in connector kit Insulator kit

Standard dimensions
IEC 62271-209 IEC 62271-209

Gross weight kg/kit


33 30

1. CD 145, connector kit. (Cable not included)

6/15 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Technical specification and accessories CD 145 kV

Pressure ring for CDI 145. 320

Dimensions in mm

470 mm 14 (12x)

1149 mm

283 345

To be ordered separately for connecting CD 145 to a transformer (TRF)

CST 170 Corona shield. (optional)

CBT Contact bolt. (optional)

Accessories, to be ordered separately

Designation CST 170 CBT 84-170 ECDI

Description Corona shield Contact bolt for TRF Extension

ECDI IEC Extension adapter will extend the height of CD 145 with 287 mm to be fitted into conventional transformers with a height of 757 mm. (optional)

IPC Protective cover for Insulator.

SH 80, SH 130 Tool for peeling and stripping of XLPE-insulation and outer conductive layer.

FK-SH 80, FK-SH 130 Spare peeling blade to be used with SH 80 and SH 130.

RKM 145 Installation tool.

OKT Optical fiber kit for cables with integrated optical fibers in the earth screen.

IK-SH 80, IK-SH 130 Spare stripping blade to be used with SH 80 and SH 130.

SLK-SH 80, SLK-SH 130 Slot knife for peeling and stripping tool SH80 and SH130. To be used to make the slot in the XLPEinsulation of the cable.

BSL-SH 130 Slot knife base plate for SLK-SH 130 and stripping blade IK-SH 130.

Designation IPC RKM 145 OKT JSA, SCK*

Description Installation protective cover Installation tool Optical fiber kit Earthing kit, se page 6/21

* NB: if earthing kit is required, this increases the cable outer diameter by 20 mm.

Designation SH 80, SH 130 IK-SH 80, IN-SH 130 FK-SH 80, FK-SH 130 SLK-SH 80, SLK-SH 130 BSL-SH 130

Description Peeling and stripping tool Spare stripping blade Spare peeling blade Spare stripping blade Base plate for slot knife and stripping blade
6/16

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

Cable termination for connection to gas-insulated switchgear (GIS), APEGA 84420 kV transformers (TRF), APEGA 84420 kV
Use Suitable for installations where the termination is to be used as a fixed connection point in gas-insulated switchgears or in transformers. Standard Meets the requirements of: IEC 60840, < 170 kV IEC 62067, 245420 kV IEEE 48 Design The cable termination consists of an epoxy insulator standing on a box body made of aluminium alloy. The field controlling component is a stress cone made of rubber. The insulator is filled with synthetic insulating oil. A flange for insulated installation is integrated in the epoxy insulator. A pressure ring is also included, see next page. For the maximum permissible diameter across the sheath of the cable and the diameter across the prepared cable insulation, see the table below. Installation Installation can be simplified by assembling the termination horizontally on the ground before lifting it into place. The following cable data should be stated when ordering: Voltage Diameter across prepared insulation Conductor cross section Conductor material, Cu or Al Screen, cross section and type Outer diameter of the cable If optical fibres in screen Type of connector: Bolt as standard Weld (up to 170 kV)
APEGA 84

top fitting

epoxy insulator syntetic insulating oil stress cone pressure ring

box body

cable clamp

APEGA 170

APEGA 245 APEGA 300 APEGA 420

Voltage kV 84 170 245 300 420

Cable insulation mm min 25 45.5 73 73 80 max 66 100 120 120 124

Outer sheath mm 85 150 160 160 160

6/17 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Technical specification for connecting APEGA 84420 to a gas-insulated switchgear (GIS)

Expansion vessel

690 640

Dimensions in mm

18 (20x)

448

AF 420 Adapter flange for APEGA 420. It is included in the kit of APEGA 420.

c 270 320

12 (8x) 14 (12x) d

217 300 Pressure ring for APEGA 84.

270 345 Pressure ring for APEGA 170.

b a Pressure ring for APEGA 245420.

APEGA 245300 420

a 612 570

b 450 464

c 582 535

d 18 (16x) 14 (20x)

Voltage kV 84 170 245 300 420

Designation

Standard A mm

Dimensions B mm 587 757 960 960 1400 mm 245 298 450 450 614

Net weight kg/item 55 75 270 270 400

APEGA 841 APEGA 1703 APEGA 2456 APEGA 3006 APEGA 4202

IEC 62271-209 IEC 62271-209 IEC 62271-209 IEC 62271-209 IEC 62271-209

~ 1030 ~ 1460 ~ 1670 ~ 1670 ~ 2175

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/18

Technical specification for connecting APEGA 84420 to a transformer (TRF)

CST 84/CST 170

Expansion vessel

CST 245420

Expansion vessel

Dimensions in mm

B B A A

Dimension drawing for APEGA 84170 kV.

Dimension drawing for APEGA 245420 kV.

Voltage level kV 84 170 245 300 420

Designation

Dimensions standard

Dimensions A 1150 1580 1830 1830 2335 B mm 707 877 1120 1120 1560

Weight kg/item 245 298 450 450 614 55 75 270 270 400

APEGA 841 TRF * APEGA 1703 APEGA 2456 APEGA 3006 APEGA 4202

EN 50299 EN 50299 EN 50299 EN 50299 EN 50299

*Corona shield CST 84, included in the kit.

To be ordered separately for connecting APEGA in a transformer (TRF)


370 160 300 220

20/30/40

30/40/50/60

292.5 170

32

8 CST 84, CST 170 Corona shield for installing APEGA 84 kV and APEGA 170 kV. CST 245420 Corona shield for installing APEGA 245420 kV. AFT 1703 Adapter flange for welding between APEGA 170 kV and transformer box. CBT 84170 For installing APEGA 84170 kV. CBT 245420 For installing APEGA 245420 kV.

Designation CST 170 CST 245-420 AFT 1703 CBT 84-170 CBT 245-420

Description Corona shield Corona shield Adapter flange Connection bolt Connection bolt

Application area For installing APEGA 170 kV For installing APEGA 245-420 kV Adapter flange to be welded between termination and transformer For installing APEGA For installing APEGA

6/19 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Tools and accessories, to be ordered separately APEGA 84420 kV

SPT 1 Circlip pliers for installation of top fitting.

SPV 1 Panduit pliers for bundle tape APEGA 170 kV.

DMT 1 Top fitting removal kit.

~ 500

OKT Optofiber kit for cables with integrated optical fibers in the earth screen.

RE-APEGA Re-assembly kit. Stress cone is included. Top bolt is to be ordered separately as required.

SV140, SV190, SV 215 Tools for installation of stress cones as follows: SV 140 for SKG SV 190 for SKGB SV 215 for SKGE

Designation SPT 1 OKT SPV 1 RE-APEGA DMT 1 SV 140 SV 190 SV 215

Description Circlip pliers when installing top fitting, APEGA 84170. Optofiber kit for cables with integrated optical fibers in the earth screen. Panduit pliers for installation of bundle tape around stress cone, APEGA 170. Re-assembly kits used for re-assembly of already installed terminations. Top fitting removal kit when removing top fitting, APEGA 84170. Installation tool for stress cone, SKG for cable termination APEGA 170. Installation tool for stress cone, SKGB for cable termination APEGA 245300. Installation tool for stress cone, SKGE for cable termination APEGA 420.

Designation JSA SCK

Description Earthing kit for cable with metallic sheath, e.g. lead. Not needed if cable has only Cu-wire screen. Screen connection for Al-foil radial waterproof cable. Not needed if cable has only Cu-wire screen.

See page 6/21 6/21

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/20

Earthing kits for cable terminations JSA, SCK

The earthing kit connects the screen of the cable to the termination. The earthing kit is designed to handle the total screen cross section. It also provides the cable with a sealing.

For corrugated screen made of: Aluminium: use JSA 1 Al Copper: use JSA 1 Pb Stainless steel: contact us. Note: The earthing kit increases the cable outer diameter by 20 mm.

Cable with copper wire screen only.

No earthing kit is needed.

Cable with copper wire screen and metal-PE laminate.

Use earthing kit SCK 2.

Metal-sheathed cable with or without screen.

Use earthing kit JSA 1.

Cable with copper tape screen and cable with armouring.

Contact us.

Diameter over outer sheath mm 40120* 120150* 150200* 40120* 120150* 150200* 1326 2646 4666 6686 86106 106126 126145

Designation

No. of contact plates per kit 1 2 3 4 5 6 7

Total copper equivalent cross section in earthing kit mm 130 220 330 130 220 330

No. of copper braids 6 10 15 6 10 15

For cables with

JSA 1 Al JSA 1 Al 10 JSA 1 Al 15 JSA 1 Pb JSA 1 Pb 10 JSA 1 Pb 15 SCK 2-1 SCK 2-2 SCK 2-3 SCK 2-4 SCK 2-5 SCK 2-6 SCK 2-7

Corrugated aluminium Corrugated aluminium Corrugated aluminium Corrugated copper or lead-sheathed Corrugated copper or lead-sheathed Corrugated copper or lead-sheathed Metal-PE laminated as radial watertightness Metal-PE laminated as radial watertightness Metal-PE laminated as radial watertightness Metal-PE laminated as radial watertightness Metal-PE laminated as radial watertightness Metal-PE laminated as radial watertightness Metal-PE laminated as radial watertightness

* Applicable for metalic sheath < 4 mm. For thicker metallic sheath contact us.

6/21 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Premolded one-piece cable joint without screen interruption JS 52123 kV with screen interruption JX 52123 kV
Use For jointing XLPE- or EPR-insulated 52123 kV cables with Al- or Cu-conductor and different cable sheaths. Standard Meets the requirements of: IEC 60840 including Annex H Design The joint body is made of rubber in three layers: a conductive outer layer, an insulating layer and a conductive inner layer in one piece. The cable joint is supplied with bolt connector and heat-shrink outer jacket. The joint is available in two different types JS: Straight cable joint with heat-shrink outer jacket. JX: Cross-bonded cable joint with heat-shrink outer jacket. There are cable joints for different types of cable screen C For cables with copper wire screen. P For aluminium laminated cables. M For cables with metal screen; lead, corrugated copper/aluminium or corrugated stainless steel. The following cable data should be stated when ordering: Voltage Diameter of prepared insulation Conductor cross section Conductor material Cu or Al Diameter of conductor Screen, cross section and type Outer diameter of the cable If optical fibres in screen Note: A torque wrench, mounting kit, installation cone and installation tool RKM 145 are needed for assembling. For diameter across the prepared insulation and conductor cross section, see the table. For corrugated aluminium and stainless steel, the flux is not included in the soldering kit. For flux, please contact your local supplier.
Voltage kV 52 72 123 33 33 46 Cable insulation diameter min mm 75 75 100 max Conductor cross section mm 1501600 1501600 1502500

JS Premolded cable joint without screen interruption.

JX Premolded cable joint with screen interruption.

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/22

Technical specification JS 52123 kV

Insulation diameter mm Cu-wire screen 3338 3842 4247 4754

Designation

Dimensions L mm

Net Weight kg/kit

Insulation diameter mm Cu-wire screen 3338 3842 4247 4754 5463 6375 3338 3842 4247 4754 5463 6375 3338 3842 4247 4754 5463 6375

Designation

Dimensions L mm

Net Weight kg/kit

JS-A 05210 C JS-A 05211 C JS-A 05212 C JS-A 05213 C JS-A 05214 C JS-A 05215 C JS-A 05210 P JS-A 05211 P JS-A 05212 P JS-A 05213 P JS-A 05214 P JS-A 05215 P JS-A 05210 M JS-A 05211 M JS-A 05212 M JS-A 05213 M JS-A 05214 M JS-A 05215 M

1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860

140 140 150 150 170 170 140 140 150 150 170 170 140 140 150 150 170 170

25 25 25 25 25 25 25 25 25 25 25 25 25 25 30 30 30 30

JS-A 07210 C JS-A 07211 C JS-A 07212 C JS-A 07213 C JS-A 07214 C JS-A 07215 C JS-A 07210 P JS-A 07211 P JS-A 07212 P JS-A 07213 P JS-A 07214 P JS-A 07215 P JS-A 07210 M JS-A 07211 M JS-A 07212 M JS-A 07213 M JS-A 07214 M JS-A 07215 M

1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860

140 140 150 150 170 170 140 140 150 150 170 170 140 140 150 150 170 170

25 25 25 25 25 25 25 25 25 25 25 25 25 25 30 30 30 30

5463 6375 3338 3842 4247 4754 5463 6375 3338 3842 4247 4754 5463 6375

Metal-PE laminated (PAL)

Metal-PE laminated (PAL)

Metal screen lead; corrugated Cu, Al or stainless steel

Metal screen lead; corrugated Cu, Al or stainless steel

Insulation diameter mm Cu-wire screen 4651 5157 5763 6372 7284 84100 4651 5157 5763 6372 7284 84100

Designation

Dimensions L mm

Weight kg/kit

Insulation diameter mm 4651 5157 5763 6372 7284 84100

Designation

Dimensions L mm

Weight kg/kit

Metal screen lead; corrugated Cu, Al or stainless steel JS-A 12310 C JS-A 12311 C JS-A 12312 C JS-A 12313 C JS-A 12314 C JS-A 12315 C JS-A 12310 P JS-A 12311 P JS-A 12312 P JS-A 12313 P JS-A 12314 P JS-A 12315 P 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 1860 170 170 180 190 212 220 176 180 195 198 218 226 28 28 30 30 32 32 29 29 31 31 33 33 JS-A 12310 M JS-A 12311 M JS-A 12312 M JS-A 12313 M JS-A 12314 M JS-A 12315 M 1860 1860 1860 1860 1860 1860 176 180 195 198 218 226 29 29 31 31 33 33

Metal-PE laminated (PAL)

6/23 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Technical specification JX-A 52123 kV

Insulation diameter mm Cu-wire screen 3338 3842 4247 4754 5463 6375 3338 3842 4247 4754 5463 6375 3338 3842 4247 4754 5463 6375

Designation

Dimensions L mm

Net Weight kg/kit 55 55 55 55 55 55 55 55 55 55 55 55 60 60 60 60 60 60

Insulation diameter mm Cu-wire screen 3338 3842 4247 4754 5463 6375 3338 3842 4247 4754 5463 6375 3338 3842 4247 4754 5463 6375

Designation

Dimensions L mm

Net Weight kg/kit 55 55 55 55 55 55 55 55 55 55 55 55 60 60 60 60 60 60

JX-A 05210 C JX-A 05211 C JX-A 05212 C JX-A 05213 C JX-A 05214 C JX-A 05215 C JX-A 05210 P JX-A 05211 P JX-A 05212 P JX-A 05213 P JX-A 05214 P JX-A 05215 P JX-A 05210 M JX-A 05211 M JX-A 05212 M JX-A 05213 M JX-A 05214 M JX-A 05215 M

2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200

200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235

JX-A 07210 C JX-A 07211 C JX-A 07212 C JX-A 07213 C JX-A 07214 C JX-A 07215 C JX-A 07210 P JX-A 07211 P JX-A 07212 P JX-A 07213 P JX-A 07214 P JX-A 07215 P JX-A 07210 M JX-A 07211 M JX-A 07212 M JX-A 07213 M JX-A 07214 M JX-A 07215 M

2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200

200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235 200235

Metal-PE laminated (PAL)

Metal-PE laminated (PAL)

Metal screen lead; corrugated Cu, Al or stainless steel

Metal screen lead; corrugated Cu, Al or stainless steel

Insulation diameter mm Cu-wire screen 4651 5157 5763 6372 7284 84100 4651 5157 5763 6372 7284 84100

Designation

Dimensions L mm

Weight kg/kit 60 60 60 60 65 65 60 60 65 65 65 65

Insulation diameter mm 4651 5157 5763 6372 7284 84100

Designation

Dimensions L mm

Weight kg/kit 60 60 65 65 65 65

Metal screen lead; corrugated Cu, Al or stainless steel JX-A 12310 C JX-A 12311 C JX-A 12312 C JX-A 12313 C JX-A 12314 C JX-A 12315 C JX-A 12310 P JX-A 12311 P JX-A 12312 P JX-A 12313 P JX-A 12314 P JX-A 12315 P 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 235300 235300 235300 235300 235300 235300 235300 235300 235300 235300 235300 235300 JX-A 12310 M JX-A 12311 M JX-A 12312 M JX-A 12313 M JX-A 12314 M JX-A 12315 M 2200 2200 2200 2200 2200 2200 235300 235300 235300 235300 235300 235300

Metal-PE laminated (PAL)

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/24

Tools and accessories, to be ordered separately JS and JX 52123 kV

RKM 145 Installation tool for cable joints JS and JX 52123 kV.

Installation cone Installation cone for cable joints JS and JX 52123 kV.

OKJ 2 and OKJ 3 Opto fiber kit for cables with integrated optical fibers in the earth screen. Used for JS and JX 123 kV only.

Opto fiber kits

Designation RKM 145 Installation cone

Description Installation tool Installation cone

Weight kg/unit 31 ~ 0.5

Cable joint JS 123 JX 123

Suitable opto fiber kit OKJ 2 OKJ 3

Article number 6248.0007 6248.0008

Selection guide for installation cone


Voltage level kV 52 52 52 52 52 52 72 72 72 72 72 72 123 123 123 123 123 123 Insulation diameter mm 3338 3842 4247 4754 5463 6375 3338 3842 4247 4754 5463 6375 4651 5157 5763 6372 7284 84100 JS-A/JX-A 05210 C/P/M JS-A/JX-A 05211 C/P/M JS-A/JX-A 05212 C/P/M JS-A/JX-A 05213 C/P/M JS-A/JX-A 05214 C/P/M JS-A/JX-A 05215 C/P/M JS-A/JX-A 07210 C/P/M JS-A/JX-A 07211 C/P/M JS-A/JX-A 07212 C/P/M JS-A/JX-A 07213 C/P/M JS-A/JX-A 07214 C/P/M JS-A/JX-A 07215 C/P/M JS-A/JX-A 12310 C/P/M JS-A/JX-A 12311 C/P/M JS-A/JX-A 12312 C/P/M JS-A/JX-A 12313 C/P/M JS-A/JX-A 12314 C/P/M JS-A/JX-A 12315 C/P/M Article number 4550.0272 4550.0273 4550.0274 4550.0275 4550.0276 4550.0277 4550.0272 4550.0273 4550.0274 4550.0275 4550.0276 4550.0277 4550.0278 4550.0279 4550.0280 4550.0281 4550.0282 4550.0283 Joint size Installation Cone

6/25 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Premolded one-piece cable joints without screen interruption JS 245 kV with screen interruption JX 245 kV
Use For jointing XLPE- and EPR-insulated 245 kV cables with Al- or Cu-conductor and various types of cable sheaths. Standard Meets the requirements of: IEC 62067 including Annex D Design The joint body is made of rubber in three layers: a conductive outer layer, an insulating layer and a conductive inner layer. The cable joint has a prefabricated PUR casted copper casing as a protective outer jacket. The joint is supplied complete with bolted cable connector for both conductor and screen. The joint is available in two different types JS: Straight cable joint with heat-shrink outer jacket. JX: Cross-bonded cable joint with heat-shrink outer jacket. There are joints for different types of cable screen C For cables with copper wire screen. P For aluminium laminated cables. M For cables with metal screen; lead, corrugated copper/aluminium or corrugated stainless steel. The following cable data should be stated when ordering: Voltage Diameter of prepared insulation Conductor cross section Conductor material, Cu or Al Diameter of conductor Screen, cross section and type Outer diameter of the cable If optical fibers in screen Note: Torque wrench and installation tool RKM 245 are needed for assembling (installation cone is included). For corrugated aluminium and stainless steel the flux is not included in the soldering kit. For flux, please contact your local supplier.

JS Premolded cable joint without screen interruption.

JX Premolded cable joint with screen interruption.

Voltage kV 245

cable insulation diameter min mm 74 120 max

Outer sheath max mm 143

Conductor cross section mm 5002500

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/26

Technical specification, tools and accessories JS 245 and JX 245 kV

B JX A

B JS

Description

Designation

Dimensions A mm B

Net Weight kg

6
Cable joint with casing JS-A 245 P JS-A 245 M JS-A 245 C Cable joint without casing with outer protection of heat-shrink Cable joint with casing and integrated screen interruption JS-B 245 C JX-B 245 P JX-B 245 M JX-B 245 C

2690 3250 3250 2280 2730 3060 2730

326 325 325 290 355 370 355

170200 180210 170200 170200 170200 180210 170200

JS 245 and JX 245


Insulation diameter Joint body size mm 7481 7987 8594 10 11 12 Insulation diameter Joint body size mm 92102 100110 108120 13 14 15

Accessories, to be ordered separately

RKM 245 Installation tool.

OKJ 1 Opto fiber kit for cables with integrated optical fibers in the earth screen.

Designation RKM 245 OKJ 1 Soldering kit

Description Installation tool including installation cone Kit for optical fibers For soldering of the casing halves if required (only P and C versions)

6/27 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Premolded cable joints without screen interruption SMPGB 145170 kV with screen interruption SMPGB-C 145170 kV
Use Suitable for jointing XLPE and EPR insulated cables with Al- and Cu-conductors and various types of cable sheaths. Standard Meets the requirements of: IEC 60840 including Annex H IEEE 404 Design The cable joint consists of a premolded joint tube with two premolded adapters and a bolt cable clamp. Bolt technology facilitates jointing of the conductor and also allows jointing of different sizes of cables. The cable joint SMPGB M for metallic sheathed cables includes also a prefabricated PUR casted copper casing as a protective outer jacket. For diameter across the prepared insulation and conductor diameter, see the table below. The joint is available in two different types: SMPGB: Straight cable joint with heat-shrink outer jacket. SMPGB-C: Cross-bonded cable joint with heat-shrink outer jacket. The joint is available for different types of cable screens and sheaths. C For cables with copper wire screen only. P For aluminium laminated cables. M For cables with metal screen; lead, corrugated copper/aluminium or corrugated stainless steel. The following cable data should be stated when ordering: Voltage Diameter across prepared insulation Conductor cross section Conductor material, Cu or Al Diameter over conductor Screen, cross section and type Outer diameter of the cable If optical fibres in screen Note: A torque wrench, installation cone and installation tool RKM 170 are needed for assemblying. For corrugated copper and stainless steel, the flux is not included in the soldering kit. For flux, please contact your local supplier.
SMPGB

SMPGB-C P

SMPGB-C M

Voltage level kV 145 170

Cable insulation diameter min mm 48 61 107 107 max

Conductor mm min/max 1665 1665

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/28

Technical specification SMPGB 145170 kV, SMPGB-C 145170 kV

SMPGB
Designation SMPGB 145 C SMPGB 145 P SMPGB 145 M SMPGB 170 C SMPGB 170 P SMPGB 170 M L mm 13001950 16002250 16202220 13001950 16002250 16202220 205 210 245 205 210 245
SMPGB

L B

SMPGB-C
Designation L mm 18002300 18002300 18002300 18002300 410 410 300 340
SMPGB-C M SMPGB-C P L

SMPGB-C 145 P SMPGB-C 145 M SMPGB-C 170 P SMPGB-C 170 M

Selection of cable joint according to cable insulation diameter


Voltage kV 145 145 145 145 145 145 145 145 145 145 145 145 145 170 170 170 170 170 170 170 170 Insulation diameter mm 4851 5053 5256 5559 5862 6165 6368 6671 6976 7482 8091 89100 98107 6165 6368 6671 6976 7482 8091 89100 98107 Conductor diameter* mm 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 1665 SMPGB C/P/M** SMPGB 14501 C/P/M SMPGB 14502 C/P/M SMPGB 14503 C/P/M SMPGB 14504 C/P/M SMPGB 14505 C/P/M SMPGB 14506 C/P/M SMPGB 14507 C/P/M SMPGB 14508 C/P/M SMPGB 14509 C/P/M SMPGB 14510 C/P/M SMPGB 14511 C/P/M SMPGB 14512 C/P/M SMPGB 14513 C/P/M SMPGB 1701 C/P/M SMPGB 1702 C/P/M SMPGB 1703 C/P/M SMPGB 1704 C/P/M SMPGB 1705 C/P/M SMPGB 1706 C/P/M SMPGB 1707 C/P/M SMPGB 1708 C/P/M Cable joint size SMPGB-C P/M** SMPGB-C 14501 P/M SMPGB-C 14502 P/M SMPGB-C 14503 P/M SMPGB-C 14504 P/M SMPGB-C 14505 P/M SMPGB-C 14506 P/M SMPGB-C 14507 P/M SMPGB-C 14508 P/M SMPGB-C 14509 P/M SMPGB-C 14510 P/M SMPGB-C 14511 P/M SMPGB-C 14512 P/M SMPGB-C 14513 P/M SMPGB-C 1701 P/M SMPGB-C 1702 P/M SMPGB-C 1703 P/M SMPGB-C 1704 P/M SMPGB-C 1705 P/M SMPGB-C 1706 P/M SMPGB-C 1707 P/M SMPGB-C 1708 P/M

* Manufactured according to cable specication. ** C for cables with copper wire screen only. P for aluminium laminated cables. M for cables with metal screen; lead, corrugated copper/aluminium or corrugated stainless steel.

6/29 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Tools and accessories SMPGB 145170 kV, SMPGB-C 145170 kV

Tools and accessories, to be ordered separately


Max 4 m

RKM 170 Installation tool for SMPGB joint 145170 kV.

Installation cone For installing the adapter.

OKJ 4 and OKJ 5 Opto fiber kit for cables with integrated optical fibers in the earth screen.

6
Article number 6248.0009 6248.0009 6248.0010 6248.0010 6248.0009

Opto fiber kits


Designation RKM 170 Installation cone Description Installation tool Installation cone Weight kg/item 42 ~ 0.5 Cable joint SMPGB 145170 P SMPGB-C 145170 P SMPGB 145170 M SMPGB-C 145170 M SMPGB 145170 Suitable opto fiber kit OKJ 4 OKJ 4 OKJ 5 OKJ 5 OKJ 4

Selection of installation cone and adapters according to cable insulation diameter


Voltage kV 145 145 145 145 145 145 145 145 145 145 145 145 145 170 170 170 170 170 170 170 170 Cable Insulation diameter mm 4851 5053 5256 5559 5862 6165 6368 6671 6976 7482 8091 89100 98107 6165 6368 6671 6976 7482 8091 89100 98107 14501 14502 14503 14504 14505 14506 14507 14508 14509 14510 14511 14512 14513 1701 1702 1703 1704 1705 1706 1707 1708 Cable joint size Installation cone Article number 4209.2384 4209.2385 4209.2386 4209.2387 4209.2388 4209.2331 4209.2332 4209.2333 4209.2334 4209.2335 4209.2336 4209.2337 4209.2400 4209.2331 4209.2332 4209.2333 4209.2334 4209.2335 4209.2336 4209.2337 4209.2338

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/30

Premolded cable joints without screen interuption SMPGB 420 kV with screen interuption SMPGB-C 420 kV
Use For jointing XLPE- and EPR-insulated cables with Al- and Cu-conductor and various types of cable sheaths. Standard Meets the requirements of: IEC 62067 including Annex D Design The cable joint consists of a premolded joint tube with two premolded adapters made in rubber, a bolt connector and a prefabricated PUR casted copper casing as a protective outer jacket.
SMPGB-C 420 SMPGB 420

See table below for diameter across the prepared insulation. The joint is available in two different types: SMPGB: Straight cable joint. SMPGB-C: Cross-bonded cable joint. The joint is available for different types of cable screens and cable sheaths. PAL For aluminium laminated cable. Pb For cables with metal screen; lead, corrugated copper/aluminium or corrugated stainless steel. The following cable data should be stated when ordering: Voltage Diameter of prepared insulation Conductor cross section Conductor diameter Conductor material, Cu or Al Screen, cross section and type If optical fibres in screen Note: Torque wrench and installation tool RKM 420 are needed when assemblying. For corrugated copper and stainless steel, the flux is not included in the soldering kit. For flux, contact your local supplier.

Cable insulation diameter mm 80124 80124 80124 80124

Conductor cross section mm 6302500 6302500 6302500 6302500

Screen cross section mm 95500 95500 95500 95500

Designation SMPGB 420 Pb SMPGB 420 PAL SMPGB-C 420 Pb SMPGB-C 420 PAL

6/31 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Technical specification, tools and accessories SMPGB 420 and SMPGB-C 420 kV

Dimensions in mm

575

2000
SMPGB 420

575

2000
SMPGB-C 420

Tools and accessories, to be ordered separately

Max 3 m

RKM 420 Installation tool.

OKJ 1 Opto fiber kit for cables with integrated optical fibers in the earth screen.

PD kit SMPGB 420

Integrated PD-measuring sensor for measuring of partial discharges in SMPGB 420.

Designation RKM 420 OKJ 1 PD kit SMPGB 420

Description Installation tool for SMPGB 420 kV Kit for splicing of optical fibers Integrated PD-measurement sensor for measuring of partial discharges in SMPGB 420

Net weight kg/kit 74

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/32

Accessories ARM, SKKB

ARM For restoring the armouring when jointing armoured cables. The kit consists of plastic mesh, spiral, funnel with holder, transparent tape and cast resin. The mesh and spiral are placed over the joint and sealed with the tape. The cast resin, which contains base and hardener in a partitioned bag, is mixed and poured into the funnel until the mesh is full. The maximum storage temperature for the casting resin is 30 C.
100

(mm) 140

Selection guide for ARM Selecting ARM for unknown applications requires the length of joint L and diameter over cable joint as below:

60 500 ARM kit size 1000 L (mm)

E.g. 115 and L 850 mm gives ARM 3. Other dimensions on request.

SKKB SKKB is a cross bonding kit for cables up to 170 kV. It can be mounted on already laid cable, where the load condition has changed and losses need to be reduced. It also gives the ability to optimize the cable system since cross-bonding can be done at any position along the cable.

Cable outer sheath diameter < 50 50100 100150 < 50 50100 100140 < 50 50100 100150

Designation ARM SKKB 5 PAL SKKB 10 PAL SKKB 15 PAL SKKB 5 MET SKKB 10 MET SKKB 15 MET SKKB 5 CUW SKKB 10 CUW SKKB 15 CUW

Use Armouring kit for armoured cable Al laminate as radially watertightness Al laminate as radially watertightness Al laminate as radially watertightness For metallic screen with or without copper screen wires For metallic screen with or without copper screen wires For metallic screen with or without copper screen wires Copper screen Copper screen Copper screen

6/33 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Tools and oil All dimensions in mm

140

360

Dimensions in mm

RKM 670 Cable knife, 30 mm blade.

RKM 672 Sheath removing knife, with two handles, for XLPE-insulated cable.

350

450

730R Torque wrench for bolt connectors, bolt cable lugs, overhead line clamps, etc. Supplied with 7 mm socket head, extension arm and 8 mm internal hexagon head. Torque range 650 Nm.

RKM 130 Torque wrench for bolt connectors, bolt cable lugs, overhead line clamps, etc. Torque wrench can be used with standard 1/2 sockets. Torque range 25130 Nm.

6501200

IG 18011806 Synthetic insulating oil.

RKM-PM Oil filling equipment (30 litres).

Note: For cable straightening equipment, contact us.

Designation RKM 670 RKM 672 AV 6220 730 R RKM 130 RKM-PM

Description Cable knife Sheath removing knife Sheath removing tool Torque wrench 650 Nm Torque wrench 25130 Nm Manual oil filling equipment

Designation IG 1801 IG 1803 IG 1804 IG 1805 IG 1806

Description Synthetic insulating oil Synthetic insulating oil Synthetic insulating oil Synthetic insulating oil Synthetic insulating oil

Contents litre 4 2 5 60 190

Vessel Tin Tin Tin Drum Drum

Cable accessories for XLPE-insulated cables 52420 kV | Kabeldon cable accessories 1420 kV |

6/34

Tools All dimensions in mm

322

~ 500

Dimensions in mm

MB 1 Cable sheath breaker.

SV140, SV190, SV 215 Tools for installation of stress cones as follows: SV 140 for SKG SV 190 for SKGB SV 215 for SKGE

SH 50, SH 80, SH 130 Tool for peeling and stipping XLPE-insulation and for removing outer conductive layer. The tool is available in three sizes depending on the diameter of the cable insulation in the cable as table below.

FK-SH 50, 80, 130 Spare blades to SH 50, SH 80 and SH 130 for peeling of cable insulation of cables.

IK-SH 50, 80, 130 Spare stripping blades to SH 50, SH 80 and SH 130 for stripping XLPE-insulation of cables.

SLK-SH 50, SLK-SH 80, SLK-SH 130 Slot knife for peeling and stripping tool SH. Used for tailoring slot in the cable insulation of the cable. Suitable for plug-in termination CD 145.

BSL-SH 130 Base plate for slot knife SLK-SH 130 and stripping blade IK-SH 130.

Designation MB 1 SV 140 SV 190 SV 215 SH 50 SH 80 SH 130 IK-SH 50, 80, 130 FK-SH 50, 80, 130

Description cable sheath breaker Installation tool for stress cone, SKG for cable termination APECB 84170 and APEGA 170 Installation tool for stress cone, SKGB for cable termination APECB 245300 and APEGA 245300 Installation tool for stress cone, SKGE for cable termination APECB 420 and APEGA 420 XLPE-shaver, SH 50 for cable insulation 1550 mm XLPE-shaver, SH 80 for cable insulation 4080 mm XLPE-shaver, SH 130 for cable insulation 70130 mm Spare blade for removing XLPE-insulation in SH 50, 80, 130 Spare blade for peeling XLPE-insulation in SH 50, 80, 130

Quantity per kit 2 1 1 1 1 1 1 1 1 1 1

SLK-SH 50, 80, 130 Slot knife for XLPE-shaver SH BSL-SH 130 Base plate for slot knife SLK-SH

6/35 | Kabeldon cable accessories 1420 kV | Cable accessories for XLPE-insulated cables 52420 kV

Table of contents Universal clamps

Universal clamps UKR 90, UKRA 90 UKR 200, UKRA 200 Typical applications, UKR 200,UKRA 200 7/2 7/3 7/4

Universal clamps | Kabeldon cable accessories 1420 kV |

7/1

Universal clamps UKR 90, UKRA 90

UKR 90 Use For fixing cables, tubes, hoses, etc. It will fix round profiles with 2090 mm or angular profiles with circumferences of 60300 mm. Design The bracket is made of non-magnetic hot-dip galvanized steel. The band is made of stainless steel SS 2333-02 with rounded edges and has a thickness of 0.2 mm. The band can be tightened and locked in one operation. The locking bolt is made of die-cast zinc alloy. UKRS 90 Consists of one UKR 90 and a spacer with a hexagon head wood screw for fastening on a wooden pole e.g.

13

UKR 90 Universal clamp.

35

UKRS 90 Universal clamp with spacer.

90

78
UKJ Earthing plate. UKS 90 Spacer.

Applications:

UKRA 90 Use For fixing cables with 2090 mm to the anchor bars in a cable distribution cabinet, etc. Design The bracket is made of non-magnetic hot-dip galvanized steel. The band is made of stainless steel according to SS 2333-02 with rounded edges and has a thickness of 0.2 mm. The band can be tightened and locked in one operation. The locking bolt is made of die-cast zinc alloy. A spring-loaded nut with a reversible locking washer offers a choice of fixed or flexible position and direction.

13

35

UKRA 90 Universal clamp with bracket for anchor bar.

Dimensional drawing of the anchor bar.

Designation UKR 90 UKRA 90 UKS UKRS 90 UKJ

Weight kg/item 0.17 0.23 0.28 0.45 0.14

7/2 | Kabeldon cable accessories 1420 kV | Universal clamps

Universal clamps UKR 200, UKRA 200

UKR 200 Use For bundling cables with 50275 mm. Design The bracket is made of non-magnetic hot-dip galvanized steel. The band is made of stainless steel SS 2333-02 with rounded edges and has a thickness of 0.2 mm. The band can be tightened and locked in one operation. The locking bolt is made of die-cast zinc alloy. UKRF For fixing cables, etc., to cable ladders. For use together with UKR 200. The height of the ladder profile is approx. 16 mm and will fit within the specified dimensions. The bracket is made of hot-dip galvanized steel. UKRS 200 Consists of one UKR 200 and a spacer with a hexagon head wood screw for fastening cables on a wall or a wooden pole.

55

78

UKR 200 Universal clamp.

UKRS 200 Universal clamp UKR 200 with spacer.

13 21 UKRF Fixing bracket.

UKRA 200 Use For fixing cables with of 50275 mm to the anchor bars. Design The bracket is made of non-magnetic hot-dip galvanized steel. The band is made of stainless steel SS 2333-02 with rounded edges and a thickness of 0.2 mm. The locking bolt is made of die-cast zinc alloy and can be tightened and locked in one operation. A spring-loaded nut with a reversible locking washer offers a choice of fixed or flexible position and direction.
55

UKRA 200 Universal clamp with bracket for anchor bar.

Dimensional drawing of the anchor bar.

Designation UKR 200 UKRA 200 UKRF UKRS 200

Weight kg/item 0.32 0.45 0.21 0.81

Universal clamps | Kabeldon cable accessories 1420 kV |

7/3

Typical applications UKR 200,UKRA 200

Flat configuration

UKR 200 with fixing brackets UKRF.

Universal clamp (results of testing with 2 turns of steel band). Max 275 mm L [m] max

UKR 200 with one fixing bracket, UKRF.

= Short circuit current (peak value) s C-C = Distance between cable centres L max = Distance between clamps UKR 200 with fixing bracket, UKRF UKRA 200

s [kA]

Trefoil configuration

Max 140 mm L [m] max

UKR 200 with two fixing brackets, UKRF.

s = Short circuit current (peak value) D = Outer diameter of cable L max = Distance between clamps s [kA] UKR 200 with fixing bracket, UKRF

7/4 | Kabeldon cable accessories 1420 kV | Universal clamps

List of contents Alphabetical order

List of contents Alphabetical order

8/2

List of contents alphabetical order | Kabeldon cable accessories 1420 kV |

8/1

List of contents Alphabetical order

Designation A A-TBF SKR AF 420 AFT 1703 ADAPTER AK-ADAS AK-ASA APECB-P 84420 kV APED B 52, 84 kV APED P 1236, 72 kV APEGA GIS 84420 kV APEGA TRF 84420 kV APIT 1236 kV APSEA 1236 kV APSEA 5272 kV ARM AV 6220 B

Page No. 3/13, 6/9 6/18 6/19 3/36 2/11 4/4 6/106/12 6/46/6 6/46/6 6/176/20 6/176/20 3/11 3/123/13 6/76/9 3/49, 6/33 5/7, 6/34

Designation G GB-M20 GC GB-M20 S8 GEX H HDC-A 250 A, 1224 kV HDC-A 630 A, 1236 kV HU 150 HU 200 HUF HUS I IA 1003 IA 1701 IA 1706 IA 2112

Page No. 5/7 4/12 5/7 4/4

3/413/42 3/433/44 3/52 3/52 3/52 3/52

4/12 5/5 5/5 4/12 4/12 5/3 5/3 5/3 5/3 5/3 5/3 5/3 5/3 5/3 5/3 5/3 5/3 4/12 4/12 4/12 4/12 4/13 4/13 4/13 4/13 4/13 6/34 3/16, 3/42 3/18 3/21, 3/44 3/18 3/21, 3/44 4/13 4/13 5/4

BSL-SH 130 C CBT 84170 CBT 245420 CD 145 kV CSAP-A 1224 kV CSE-A 1224 kV, 250 A CSE-A 3642 kV, 400 A CSE-A 3642 kV, 630 A CSEP-A 1242 kV CST 170 CST 84420 CU 250 CW D DMT1 F FBS-1722 1 FK FKFB FK-SH FP FPA FPMP G GAP-APECB GAP-APED

6/16, 6/35

IA 2113 IA 2333 IA 2337

6/16, 6/19 6/19 6/156/16 3/25 3/143/16 3/17-3/18 3/19-3/21 3/22-3/24 6/16 6/19 3/16 3/51

IA 2338 IA 2339 IA 2342 IA 2343 IA 2352 IA 2362 IA 2421 IA 2441 IA 2443 IA 2444 IA 2502 IA 2508 IA 2518 IA 2519

6/20

IG 1201 IG 1601 IG 1604

5/7 3/50 3/50 6/16, 6/35 4/11 4/11 4/11

IG 1717 IG 1718 IG 1801-1807 IH-A 24250 IH-A 24400 IH-A 24630 IH-A 42400 IH-A 42630 IK 1002

6/12 6/6

IK 1003 IK 1105, 1106, 1107, 1108, 1109

8/2 | Kabeldon cable accessories 1420 kV | List of contents alphabetical order

List of contents Alphabetical order

Designation I IK 1401 IK 1405 IK 1406 IK 1407 IK 1502 IK 2221 IK 2230 IK 2233 IKP IK-SH Installation cone IP 250 IP 400 IP 630 IPC IS J JP 250 JPB 630 JPA V JS/JX 52123 JS/JX 245 JSA 1 JSA 46 JSA 1016 JXT 13 K KA 250 KA 630 K-TBF 30 SKR K-TBF 40 SKR KAL 11 KAP 300 U KAP 630 K-ASA K-ASB L LPH LXAC M MA 250 MA-A 630 MB 1 MBR 250 Model 1700 Series

Page No. 5/4 5/4 5/4 5/4 5/4 5/4 5/5 5/4 4/12 6/166/35 6/25, 6/30 3/16, 3/42 3/18 3/21, 3/44 6/16 2/8, 2/9

Designation O OKJ OKT Opto kit OTIA 152 P PC 630-3 PC 630-3 L PC 630/250 PD kit SMPGB 420 PG 630 PG-A 630 PIU-APEC PIU-APED PPC Pressure ring PSSK PSSK E

Page No. 6/25, 6/27, 6/30, 6/32 6/12, 6/16, 6/20 6/14 4/3

3/21, 3/44 3/21, 3/44 3/16, 3/21, 3/44 6/32 3/21, 3/44 3/21, 3/44 6/12 6/6 2/4 6/18 3/45 3/45 3/45 4/6 4/6

3/16, 3/42 3/21 3/21, 3/44 6/226/25 6/266/27 6/21 3/47 3/48 3/47

PSSK L PXS PXSA R RE-APECB RE-APED RE-APEGA RKM 1055 RKM 1055 K RKM 130

6/12 6/6 6/20 5/6 5/6 6/34 5/6 6/16, 6/25 6/30 6/27 5/6 6/32 4/12 5/6, 6/34 5/6, 6/34 6/34 5/6 5/6 5/3

3/42 3/44 3/13, 6/9 3/13, 6/9 2/10 3/29 3/273/28 4/4 4/4

RKM 1435 RKM 145 RKM 170 RKM 245 RKM 2550 RKM 420 RKM 402 RKM 670 RKM 672 RKM-PM RKM-SB

2/8 2/9

RKS 1607 054 RULLE S

3/16, 3/42 3/21, 3/44 6/35 5/5 5/7

730 R SAGA 11 Y SCK 2 SCL-B SH

5/6, 6/34 2/5 6/21 3/51 6/16, 6/35

List of contents alphabetical order | Kabeldon cable accessories 1420 kV |

8/3

List of contents Alphabetical order

Designation S SH-SKRM SKALUS SLK-SH SMARTA SMILA SMKC SMPGB 145170 kV SMPGB 420 kV SMTA SMTD SMTPA SMTXB SMTXD SMULA SMXB SOJ SOT SPT1 SPV1 SSH STOP SV

Page No. 3/51 5/5 6/16, 6/35 2/4 2/7 2/6 6/286/30 6/316/32 4/9 4/54/6 4/9 4/7 4/8 2/7 3/393/40 3/303/38 3/53/10 6/20 6/20 3/46 3/36, 3/40 6/35

Designation T TB-A 12 TD 145 THS, THSA TS TSH U UKJ UKR 90 UKR 200 UKRA 90 UKRA 200 UKRF UKS 90 UKRS 90 UKRS 200 W WIM

Page No. 3/26 6/136/14 3/13, 6/9 3/36 3/46

7/2 7/2 7/3 7/2 7/3 7/3 7/2 7/2 7/3

3/37, 3/40

8/4 | Kabeldon cable accessories 1420 kV | List of contents alphabetical order

List of contents By category

List of contents by category

9/2

List of contents by category | Kabeldon cable accessories 1420 kV |

9/1

List of contents by category Cable terminations and Cable connectors

Cable terminations 1 kV Outdoor Outdoor 1036 kV XLPE- and EPR-insulated cable 1236 kV XLPE- and EPR-insulated cable 1236 kV XLPE- and EPR-insulated cable 1236 kV paper-insulated cable 5272 kV XLPE- and EPR-insulated cable 36 kV, 72 kV XLPE- and EPR-insulated cable 5272 kV XLPE- and EPR-insulated cable 84420 kV XLPE- and EPR-insulated cable 145 kV XLPE- and EPR-insulated cable 145 kV XLPE- and EPR-insulated cable 84420 kV XLPE- and EPR-insulated cable Cable connectors 1 kV Enclosed connection protection Prefabricated cable connection for extension of Al cable 1224 kV XLPE- and EPR-insulated cable Premolded screened separable connector Premolded screened separable connector Premolded screened separable connector Premolded parallel screened separable connector Premolded screened separable surge arrestor KAL AK-ADAS CSE-A 250 A CSE-A 400 A CSE-A 630 A CSEP-A 630 A CSAP-A 630 A Premolded indoor/outdoor Premolded, with geometrical field control, indoor Premolded, with geometrical field control, outdoor Indoor Porcelain insulator Composite insulator Flexible, made of rubber Composite insulator Composite insulator, DRY, outdoor Plug-in, DRY, indoor GIS and TRF LPH LXAC SOT 1036 kV APIT 1236 kV APSEA 1236 kV OTIA 12 kV APED 52, 84 kV APED-P 1236, 72 kV APSEA 5272 kV APECB-P 84420 kV TD 145 kV CD 145 kV APEGA 84420 kV

See page 2/8 2/9 3/53/10 3/11 3/123/13 4/3 6/46/6 6/46/6 6/76/9 6/106/12 6/136/14 6/156/16 6/176/20 See page 2/10 2/11 3/143/16 3/173/18 3/193/21 3/223/24 3/25 See page Shrouded termination, 12 kV indoor Shrouded termination, 1224 kV indoor Shrouded termination, 1224 kV indoor TB-A KAP 630 KAP 300 U 3/26 3/273/28 3/29

3642 kV XLPE- and EPR-insulated cable 3642 kV XLPE- and EPR-insulated cable 1242 kV XLPE- and EPR-insulated cable 1224 kV XLPE- and EPR-insulated cable Shrouded terminations 1224 kV XLPE- and EPR-insulated cable

9/2 | Kabeldon cable accessories 1420 kV | List of contents by category

List of contents by category Cable joints

Cable Joints 1 kV Cast resin for plastic-, paper-insulated and signal cable Branch joint for plastic-insulated cable Heat-shrink for plastic-insulated cable Tape for plastic-insulated cable with screen Tape for plastic-insulated cable without screen 1236 kV XLPE- and EPR-insulated cable 1236 kV Paper-insulated cable Premolded Tape Joint Repair joint Transition joint Transition joint Joint Joint, separated lead-sheathed cable 52420 kV XLPE- and EPR-insulated cable Premolded Premolded Premolded with screen interruption Premolded with screen interruption Premolded Premolded 1236 kV Cable distribution cabinet 1236 kV Cable distribution cabinet Kabeldon cable cabinet, 250 A Kabeldon cable cabinet, 630 A HDC-A 1224 kV HDC-A 1236 kV SMARTA SAGA Y SMKC SMILA SMULA SOJ 1236 SMXB 1236 SMTD 12 kV SMTD-RK 12 kV SMTXB 12 kV SMTXD 2436 kV SMTA 2436 kV SMTPA 52 kV JS 52123 kV JS 245 kV JX 52123 kV JX 245 kV SMPGB 145170 kV, SMPGB-C 145170 kV SMPGB 420 kV

See page 2/4 2/5 2/6 2/7 2/7 3/303/38 3/393/40 4/54/6 4/54/6 4/7 4/8 4/9 4/9 6/226/25 6/266/27 6/226/25 6/266/27 6/286/30 6/316/32 See page 3/413/42 3/433/44

List of contents by category | Kabeldon cable accessories 1420 kV |

9/3

List of contents by category Accessories for cable accessories

Accessories Accessories for XLPE- and EPRinsulated Cable accessories 1236 kV Screen separation kit Branch seal for 3-core cable terminations Earthing kit for terminations Screen connection for joints Armouring kit Overhead line clamp Bolt cable lug Bolt connector Accessories for paper-insulated cable accessories 1236 kV General accessories 1236 kV Spring-loaded gaskets General accessories Bird protection Tapes Other accessories Tools Accessories for cable accessories 52420 kV Earthing kits for cable terminations Armouring kit Cross bonding kit Tools and oil General accessories Universal clamps UKR 90 UKRA 90 UKR 200 UKRA 200 JSA 1 , SCK 2 ARM SKKB PSSK, PSSK-E, PSSK L TSH, SSH JSA 46 and JXT 13 JSA 1016 ARM FK 120 och FK 300 SCL-B SH-SKRM FPA, FP och FPMP

See page 3/45 3/46 3/47 3/48 3/49 3/50 3/51 3/51 4/11 4/124/13 3/2 5/3 5/45/5 5/65/7 6/21 6/33 6/33 6/34 7/2 7/2 7/3 7/3

9/4 | Kabeldon cable accessories 1420 kV | List of contents by category

Contact us

ABB AB Kabeldon BOX 531 SE-441 15 Alingss, Sweden Tel: + 46 322 770 00 Fax: +46 322 770 01 e-mail: info.sedon.kabeldon@se.abb.com www.abb.com/cableaccessories

Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2013 ABB All rights reserved

Document ID: 7ABA102366

Das könnte Ihnen auch gefallen