Sie sind auf Seite 1von 18

Forensic Science International,

51 (1991) 203- 220

203

Elsevier Scientific Publishers

Ireland Ltd.

MICROSPECTROFLUORIMETRY OF FLUORESCENT DYES AND BRIGHTENERS ON SINGLE TEXTILE FIBRES: PART 1 FLUORESCENCE EMISSION SPECTRA

ANDREW W. HARTSHORNE

and DAVID K. LAING


Home Office Forensic Science Service, Aldermaston.

Central Research and Support Establishment, Reading, Berkshire, RG7 LPN (U.K.)

(Received January llth, 1991) (Accepted August 23rd, 1991)

Summary
Objective discrimination of fluorescent brighteners on single textile fibres is difficult to achieve by current methods; the technique of microspectrofluorimetry provides a solution to this problem. The modifications necessary to convert a microspectrophotometer into a microspectrofluorimeter and the limitations imposed by such conversion are described. The use of the instrument for the discrimination of fluorescent brighteners and fluorescent red dyestuffs on single fibres is also examined.
Key words: Microspectrofluorimetry;

Single fibres; Dyes; Brighteners;

Emission spectra

Introduction Microspectrophotometry and complementary tristimulus calorimetry, using the NanoSpec 10s microspectrophotometer (Nanometrics, Sunnyvale, CA, U.S.A.), have been shown to be suitable methods for discriminating and colour coding single fibres [l - 41. By its nature, microspectrophotometry is of limited use with uncoloured fibres. As these comprise about 37% (Home Office Forensic Science Service report, unpublished results) of the Home Office Forensic Science service (HOFSS) Fibre Data Collection [5], a technique for their discrimination would be of value. Such fibres, however, will often fluoresce when irradiated with UV light, due to the presence of fluorescent brighteners. These serve to enhance the reflectance of the fibre at the blue end of the spectrum by converting UV radiation into visible blue light, so reducing unwanted yellowness. Few methods exist for the comparison of fluorescent brighteners on single textile fibres. The use of thin layer chromatography has been reported [6-81, but the procedure described is somewhat inconvenient. Characterisation by high performance liquid chromatography has also been described [9], but this is applicable only to bulk samples, not the limited amount of material extracted from brighteners often single fibres. Once extracted into solution, fluorescent undergo photodegradation and photoisomerism [6]. To prevent this, the use of a photographic safe light is necessary.
Printed and Published in Ireland

204

The only other directly applicable examination method for these materials is fluorescence microscopy [lo], used extensively by forensic fibre examiners. However, just as the comparison of coloured fibres can be made more objective by the use of microspectrophotometry, then the technique of microspec[ 11,121 should provide a similar advance in the discrimination of trofluorimetery fluorescent brighteners. In addition, as certain coloured dyestuffs are themselves fluorescent, then microspectrofluorimetry with appropriate excitation wavelengths may provide additional discrimination above that obtained by microspectrophotometry alone. To convert the NanoSpec 10s microspectrophotometer into a microspectrofluorimeter, several modifications are necessary, the most obvious being the provision of a suitable excitation source. The Leitz Ortholux II microscope (E Leitz, Wetzlar, Germany) allows excitation by either incident or transmitted light. Incident light excitation is preferred as it generally produces a more intense fluorescence emission [lo], but this introduces the problem of the exciting and emitted light travelling in opposite directions along the same optical path. Separation of the two may be achieved by a dichroic beam-splitting mirror according to Ploem [13], which reflects short wavelength light from the source onto the sample, but transmits long wavelength fluorescence from the sample onto the detector. In a conventional spectrofluorimeter, isolation of the desired excitation wavelengths is achieved by monochromation, making possible the measurement of fluorescence excitation spectra. With the proposed microspectrofluorimeter, excitation monochromation is not possible, band-pass filters being used instead. As glass optics and slides are used, the shortest excitation wavelength achievable is about 360 nm. This has the advantage of almost completely removing the problem of native fluorescence from the substrate fibre, as only wool is fluorescent above this wavelength [14]. Unless correction procedures are employed, measured fluorescence emission spectra are dependent upon the optical system employed and the efficiency of the photomultiplier tube detector; any quantitative results are applicable only to the individual instrument used. All the instrumental variables may be combined into a single parameter called the optical transfer function. The design of the Nanometrics SDP2000 data processor allows this function to be determined and corrected spectra to be obtained. This work therefore describes the modifications made to the NanoSpec 10s to convert it into a microspectrofluorimeter and the measurement method employed. Following assessment of instrument performance, the discrimination of fluorescent fibres on the basis of their emission spectra is investigated. Experimental
Instrument assessment and method of measurement

To obtain fluorescence emission spectra from single fibres, modifications were made to the standard [2] NanoSpec 10s microspectrophotometer system, the modified instrument being shown in Fig. 1.

205

Entrance slit

viewer

Dlchrolc

mirro

Fluotar

objectwe

ransrnlsswn

illuminator

Fig. 1. Schematic diagram of the microspectrofluorimeter.

The Ortholux II microscope. The excitation source employed was a Wotan HBO 50 W mercury lamp (Osram GmbH, Berlin, Germany), attached to the microscope via a multiple mirror housing, this latter enabling either of two attached sources to be used to provide incident or transmitted light illumination. The microscope was fitted with a x 25 Fluotar objective and adjusted to provide Koehler illumination [13] in both modes. For microspectrofluorimetry, isolation of the desired excitation wavelengths was achieved using a Leitz Ploemopak Fluorescence Illuminator, which contains two filter cubes. Each cube consists of three components. The first component in the optical path is a band-pass interference filter to isolate the excitation wavelengths from the incident radiation. These then impinge on a dichroic beamsplitting mirror placed at 45 degrees to the microscope axis and are reflected onto the sample. The longer wavelength fluorescence emitted by the sample passes through the dichroic mirror and a long-pass suppression filter, the latter removing any residual excitation wavelengths reflected from the sample and transmitted by the mirror. The arrangement of these components within the cube is shown in Fig. 1. Two cubes, designated A and H2, were used to provide excitation illumination. Cube A has an excitation range of 340-380 nm, with fluorescence emissions being detectable above 430 nm. Cube H2 has correspon-

206

ding values of 390-490 nm and 515 nm. These values were checked using a Hewlett-Packard HP8450A spectrophotometer (Hewlett-Packard, Winnersh, Berkshire, U.K.). Two further cubes, TU55 and TL, fitted to the illuminator allow normal incident and transmitted light microscopy respectively. The NanoSpec 10s microspectrophotometer head. This was operated as for microspectrophotometry [3], except that the entrance slits were adjusted to span the full width of the fibre under examination, instead of just the central third. This allows more light to be directed onto the detector. No unwanted refraction effects [4] should be introduced, as fluorescence radiation is emitted randomly in all directions [15]. The SDPf2000 spectral data processor. This was set to record spectra over the wavelength range 390- 710 nm, at a scan speed of 200 nm/min, although the characteristics of the cubes mean that measured intensities below the cut-off wavelengths must be ignored. The SDP2000 was also used to correct fluorescence emission spectra to allow for the instrument s optical transfer function. This procedure depends on the quartz-halogen lamp fitted to the microscope being equivalent to the Commission Internationale de 1 Eclairage (CIE) Illuminant A [16]. By determining the spectral power distribution of the quartz-halogen source with the microspectrofluorimeter and comparing these values with those for Illuminant A programmed into the SDP2000, correction factors for each wavelength can be computed. These are stored in the SDP2000 memory for the correction of subsequent fluorescence spectra. To establish that the quartz-halogen lamp and CIE Illuminant A were equivalent, the spectral power distribution of the quartzhalogen lamp was determined over the range 5-9 V. In addition, the emission spectrum of the mercury lamp was also determined, using a slow scan speed of 20 nmlmin to ensure adequate resolution of spectral features. When used for correction, the intensity of the quartz halogen lamp needs to be attenuated [17], to be comparable with the moderate intensity of most fluorescence emissions. This was achieved by means of a circular metal disc, drilled with a central 3.44 mm diameter hole, placed behind the quartz-halogen lamp diffuser disc. The chart recorder, analogue-to-digital converter and PET microcomputer system. These components were employed as in microspectrophotometry with the fluorescence emission spectra being stored on disk. Wavelengths at which no emission could be observed, due to the suppression filters cut-off limits, were arbitrarily given emission intensities of zero. This prevents any negative values being recorded, which may result from measurement inaccuracies at low light levels. Taking into account the factors described above, a standard measurement protocol for obtaining fluorescence emission spectra from single textile fibres was developed, which may be summarised as follows: (1) Move the fibre to be measured under the slits, adjusting the slit size to suit. (2) Move the required illumination cube into the optical train, set transmitted light quartz-halogen illumination and switch on the SDP2000 correction facility. (3) Move the fibre to one side of the slits and obtain the optical transfer function by scanning through from 390 - 710 nm, storing it in the SDP2000 memory.

207

(4) Move the fibre back under the slits, set reflected-light mercury illumination and switch off the correction facility. (5) Scan again, ratioing the signal with the optical transfer function stored in memory, the SDP2000 output being the fibre s fluorescence emission spectrum. This standard protocol was then used to assess the stray light [17] performance of the microspectrofluorimeter, by measurement of the fluorescence emission spectrum of a National Physical Laboratory (Teddington, Middlesex, U.K.) opal glass white diffuse reflectance standard [6]. This material is nonfluorescent, so any radiation received by the detector must be due to stray light. Use of this material ensures maximum collection of any extraneous radiation, thus representing the worst possible measurement conditions. Both cubes A and H2 were used for excitation. Microspectrojluorimetry of visually colour-matched samples From dye manufacturers pattern cards, 11 similarly coloured red dispersedyed polyester samples were selected. All were known to be fluorescent and are listed in Table 1, with their Colour Index [18] generic names. With the exception

TABLE 1 COLOUR-MATCHED RED POLYESTERS BY MICROSPECTROFLUORIMETRY


Dye manufacture+ and dye&u. (no., name)

AND FLUORESCENT

BRIGHTENERS

EXAMINED

Dye
CO?K.

CI Disperse Red

CI Fluorescent Brightener

CI Constitution

70

Number

Red disperse dyes 1 YCL Serisol Fast Pink RFL 2 YCL Serilene Brill. Pink R-LS 3 YCL Serilene Pink GLS 4 CGY Terasil Brill. Pink FG 5 CGY Terasil Brill. Pink B 6 CGY Terasil Brill. Pink 2GL 7 CGY Terasil Brill. Pink 4BN 8 CGY Terasil Brill. Pink 3G 9 CGY Terasil Red G 10 ICI Dispersol Red B-2B 11 SDZ Foron Brill. Red E-2BL Fluorescent 1 2 3 4 5 brighteners 0.4 0.4 0.4 0.4 * _ _ 179 162:l _ _ _ _ 2.5 3.0 3.0 4.0 5.0 2.0 3.0 3.6 2.0 4.5 5.0 59 96 86 55 91 86 II 302 _ 60 60 _ _ _ _ _ -

62175

62175 62015 _ _ 60756 60756

ICI Fluolite XMF SDZ Leucophor EFR SDZ Leucophor EFG SDZ Leucophor EFA Nylon Baby knitting yarn

a(CGY) Ciba-Geigy, Clayton, Manchester; (ICI) ICI Organics Division, Blackley, Manchester; (SDZ) Sandoz, Horsforth, Leeds; (YCL) Yorkshire Chemicals, Leeds. *Dye concentration unknown.

208

of Terasil Red G, which could not be located in the Colour Index, all were anthraquinone derivatives. Well teased-out fibres from each sample were mounted on slides, using XAM neutral medium improved white (BDH, Poole, Dorset, U.K.) and a coverslip. It has been shown [19] that XAM is not itself fluorescent. With cube A in place in the microscope light train, five replicate determinations of the fluorescence emission spectrum were made for each sample, using the standard measurement protocol. Replication allows measurement reproducibility to be assessed; different fibres were used for each measurement. This procedure was then repeated for excitation with cube H2. Comparison microscopy, under both white light and cubes A and H2 excitation and visible microspectrophotometry were also performed on the samples. This enabled the discrimination power [20] of microspectrofluorimetry to be compared with those of existing examination methods. Spectral comparison for both microspectrophotometry and microspectrofluorimetry was achieved by overlaying spectra on a light box. Microspectrojluorimetry of jluorescent brighteners A selection of five fluorescent brighteners was examined by microspectrofluorimetry. These were taken from dye and yarn manufacturers pattern cards and are detailed in Table 1. Only two could be located in the Colour Index and were a triazine and a naphthalic acid derivative respectively. As before, fibres from each sample were mounted on slides and five determinations of the fluorescence emission spectrum made, according to the standard measurement protocol. Cubes A and H2 were both used for isolation of the exciting radiation. Comparison microscopy, using white light and cube A and H2 illumination, was also performed and the discrimination power of each method calculated.

5iO

Wavelength
Fig. 2. Emission spectrum of the mercury lamp.

209

Results and Discussion Instrument assessment and method of measurement The mercury lamp emission spectrum is shown in Fig. 2. It takes the form of a low intensity continuous background output of radiation on which is superimposed a number of intense emission lines. As the excitation wavelength range of fluorescent materials coincides with several of these lines [21], the low intensity of the continuum is not a disadvantage. UVNisible spectrophotometry of the components of cubes A and H2 revealed that the reported characteristics were accurate. In consequence, fluorescence emission spectra may be obtained over the ranges 430-710 nm for cube A excitation and 520 - 710 nm for cube H2. However, it was also found that while cube H2 transmits a reasonable amount of the excitation illumination over its effective range (around 70% of the source), cube A transmits only 14%. In practice, further intensity losses will be caused by the glass contained in the microscope objective and sample slide, which could be avoided by the use of quartz objectives, slides and cover slips, but only at great expense. The spectral power distributions of the quartz-halogen lamp at a number of voltages are shown in Table 2, with the differences from CIE Illuminant A 1161 plotted in Fig. 3. In general, the differences between the two are small, the greatest fractional deviation being of the order of 1%. There appear to be no significant differences between the sets of results obtained over the range 5 - 8 V, but the deviations at 9 V tend to be greater than those at the other voltages. These results indicate that usage of CIE Illuminant A values for correcting fluorescence emission spectra is valid. As microspectrophotometry on the same instrument is usually performed with a lamp voltage of 5 V, then to avoid unnecessary adjustment (and possible instability) of the light source, this voltage was adopted for all subsequent microspectrofluorimetric work. The cubes A and H2 optical transfer functions obtained at this voltage are shown in Fig. 4. The spectra obtained from the stray light assessment were found to contain emission bands at wavelengths identical to those of a mercury lamp, but of very low intensity. However, this radiation was found to arise not from the mercury lamp source used, but from the fluorescent tubes providing general laboratory illumination. Repeating the measurements with the laboratory lights off gave a measured emission intensity of zero at all wavelengths. As described, the microscope and Ploemopak Fluorescence Illuminator are identical to the arrangement used in the HOFSS for comparison fluorescence microscopy. This allows a strict comparison of the discrimination powers of fluorescence microscopy and microspectrofluorimetry to be made. Microspectrojluorimetry of visually colour-matched samples Examples of the fluorescence emission spectra obtained by cube H2 excitation of the 11 colour-matched red polyesters are shown in Fig. 5, the spectra being offset for clarity. It can be seen that eight dyes gave fluorescence emission maxima around 600 nm; the exceptions (spectra 7,10 and 11) being at slightly longer wavelengths. Replicate spectra from the same sample were virtually in-

210

TABLE

2 OF QUARTZ-HALOGEN MICROSCOPE LAMP WITH CIE ILLUMINANT A

COMPARISON

Wavelength True Illumi(nm) nant A


valzd (x 10) 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600 610 620 630 640 650 660 670 680 690 700 710 121 147 177 210 247 287 331 378 429 483 539 599 661 725 791 860 929 1000 1072 1144 1217 1290 1363 1436 1508 1580 1650 1720 1788 1854 1919 1983 2044

Measured intensity and di@rence from true at lamp voltage (V)


5.0 6.0 7.0 8.0 9.0

128 142 174 214 240 284 328 382 426 480 533 592 666 722 778 852 928 994 1072 1134 1202 1290 1356 1432 1496 1564 1640 1706 1780 1832 1902 1972 2027

+7 -5 -3 +4 -7 -3 -3 +4 -3 -3 -6 -7 +5 -3 -13 -8 -1 -6 0 -10 -15 0 -7 -4 -12 -16 -10 -14 -8 -22 -17 -11 -17

127 142 174 214 240 284 328 382 424 480 533 590 666 722 776 852 920 994 1072 1130 1202 1288 1356 1432 1493 1564 1638 1706 1775 1832 1896 1968 2024

+6 -5 -3 +4 -7 -3 -3 +4 -5 -3 -6 -9 +5 -3 -15 -8 -9 -6 0 -14 -15 -2 -7 -4 -15 -16 -12 -14 -13 -22 -23 -15 -20

125 142 174 210 240 284 328 382 426 480 529 592 664 722 776 852 928 994 1070 1130 1202 1290 1356 1432 1496 1564 1640 1706 1772 1836 1894 1968 2029

+4 -5 -3 0 -7 -3 -3 +4 -3 -3 -10 -7 +3 -3 -15 -8 -1 -6 -2 -14 -15 0 -7 -4 -12 -16 -10 -14 -16 -18 -25 -15 -15

126 142 174 212 240 284 328 382 424 480 524 590 660 722 776 852 924 992 1070 1128 1202 1285 1356 1430 1488 1564 1638 1706 1777 1836 1896 1970 2024

+5 -5 -3 +2 -7 -3 -3 +4 -5 -3 -15 -9 -1 -3 -15 -8 -5 -8 -2 -16 -15 -5 -7 -6 -20 -16 -12 -14 -11 -18 -23 -13 -20

127 142 174 208 240 284 328 374 416 476 524 590 656 722 776 842 918 984 1052 1126 1198 1278 1354 1424 1486 1559 1630 1699 1770 1828 1892 1966 2018

+6 -5 -3 -2 -7 -3 -3 -4 -13 -7 -15 -9 -5 -3 -15 -18 -11 -16 -20 -18 -19 -12 -9 -12 -22 -21 -20 -21 -18 -26 -27 -17 -26

aFrom Reference 20.

211
30

-5v ;.-fJ/
c-7v ,-av

-9v

500

550

600

650

7oc

Wavelength Fig. 3. Difference in relative intensity between the quartz-halogen nant A at various lamp voltages. microscope lamp and CIE Illumi-

distinguishable in most cases, measurement reproducibility being comparable to that of microspectrophotometry. In general, spectra obtained for cube A excitation were similar in shape to those from cube H2, but of much lower intensity. This accords with the principle that the wavelength of excitation does not affect the shape of the emission spectrum, only its absolute intensity [21]. It does however show that the dyestuffs

CubeA

Cube H2

-c

710

390

550

710

Wavelength (nm)
Fig. 4 Cubes A and H2 optical transfer functions obtained using the microspectrofluorimeter.

212

3 4 5 Absorbance 6

8 9

710

520

710

Wavelength
Fig. 5. Visible absorption and cube H2 fluorescence emission spectra of colour-matched red polyester fibres (for sample identification, see Table 1).

TABLE 3 DISCRIMINATION OF COLOUR-MATCHED RED POLYESTER FIBRES Sample


no.

10

11

a
0 0

Cube A fluorescence emission spectra (DPb = 43155 = 0.78) 1 *** 0 10 1 0 1 2 *** 1 1 1 1 1 3 *** 1 1 1 1 4 *** 0 0 1 5 *** 0 1 6 *** 1 *** 7 8 9 10 11 Cube A comparison fluorescence microscopy (DP = 36155 = 0.66) 1 *** 0 1 1 0 0 1 2 *** 0 1 0 0 1 3 *** 0 0 0 1 4 *** 0 0 1 5 *** 0 1 6 *** 1 7 *** 8 9 10 11 Cube HZ fluorescence emission spectra (DP = 52/55 = 0.95) 1 *** 0 1 1 1 1 1 2 *** 1 1 1 1 1 3 *** 1 1 1 1 4 i** 0 1 1 5 *i* 1 1 6 *** 1 7 *** 8 9 10 11 Cube H2 comparison fluorescence 1 *** 0 0 2 *** 0 3 *** 4 5 6 7 8 9 10 11 microscopy (DP 1 0 0 1 0 0 *** 0 *** = 38/55 0 0 0 0 1 ***

1 0 0 0 1 ***

1 1 1 1 1 0 1 1 ***

1 1 1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 1 1 ***

0 0 0 0 0 0 1 ***

1 1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 1 0 ***

1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 1 0 ***

= 0.69) 1 1 1 1 1 1 ***

0 0 1 0 0 0 1 ***

1 1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 1 1 ***

214 TABLE 3 (continued) Sample


nO.a

10

11

Visible absorbance spectra 1 *** 0 2 *** 3 4 5 6 7 8 9 10 11

(DP = 44/55 = 0.80) 1 0 0 1 0 0 *** 1 1 *** 0 ***

1 1 0 1 1 ***

1 1 1 1 1 1 ***

0 0 1 0 0

1 1 ***

1 1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 1 ***

Visible comparison microscopy (DP = 36/55 = 0.66) 1 *** 0 0 1 1 0 2 *** 0 1 0 0 3 *** 0 0 0 4 *** 0 0 5 *** 0 6 *** 7 8 9 10 11 YSeeTable 1 for sample identification. bDP, discrimination power. (0) Undiscriminated. (1) Discriminated.

1 1 1 1 1 1 ***

0 0 0 0 0 0 1 ***

1 1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 1 ***

1 1 1 1 1 1 1 1 1 0 ***

examined are excited more efficiently by violet/blue wavelengths, rather than the ultraviolet. Table 3 summarises the resultant spectral comparisons. Of the 55 possible pairings, 43 are discriminated by cube A excitation and 52 by cube H2, giving discrimination powers of 0.78 and 0.95, respectively. The better performance of cube H2 is not surprising, as it gives a greater emission intensity, enabling small spectral differences to be resolved. One of the pairings found identical by cube H2 excitation was discriminated by cube A, thus giving an overall discrimination power of 0.96. From Fig. 5, it can be seen that many spectra gave two closely spaced emission maxima. While in many pairings, the wavelengths of the emission maxima were identical, discrimination could be achieved on the basis of their relative intensities. Table 3 also gives the results of comparison fluorescence microscopy for both illumination conditions; the discrimination powers being 0.66 for cube A and 0.69

215

for cube H2. This indicates that the more objective comparison method of microspectrofluorimetry does give a much improved performance, particularly for cube H2 excitation, due to the discrimination of metameric pairs. Of course, all spectrally identical pairs should appear visually identical, but in practice this may not be so, due to instrumental errors and imbalances in the comparator illumination. This was found to be the case, with two cube A and one cube H2 spectrally identical pairs being discriminated by fluorescence microscopy. The relative brightness of the fluorescence emissions is also a factor in visual discrimination. Without comparison against a fluorescence standard, no account can be taken of this feature when comparing spectra. For visible light comparison microscopy and microspectrophotometry, the respective discrimination powers achieved for this set of colour-matched fibres were 0.66 and 0.80, as given in Table 3. Typical absorbance spectra from each dyed fibre are given in Fig. 5 (spectra offset for clarity). From this, it can be seen that all absorbance maxima are in the range 500 - 560 nm. Further consideration of Fig. 5 shows that in general, fluorescence emission maxima occurred at wavelengths around 60-70 nm higher than the corresponding absorbance maxima, in accordance with Stokes Law [21]. It can also be seen that the emission and absorbance spectra bear an approximate mirror image relationship to each other; a slow rise and sharp fall in absorbance being contrasted with a sharp rise and slow fall in fluorescence. Another point of similarity is that dyes having two absorbance maxima generally gave two fluorescence emission maxima. For these dyed fibres, comparison fluorescence microscopy therefore provides little additional discrimination over ordinary comparison microscopy; indeed most of the undiscriminated pairs were common to the two methods. However, microspectrofluorimetry gives an increase in discrimination over that of microspectrophotometry. Overall, discrimination power increases in the order visible microscopy, fluorescence microscopy, microspectrophotometry and microspectrofluorimetry. Although only tested on red dyestuffs, this result indicates that microspectrofluorimetry offers considerable promise as a discrimination technique for single textile fibres dyed with fluorescent dyes. Microspectrofluorimetry of fluorescent brighteners Typical fluorescence emission spectra obtained by cubes A and H2 excitation are given in Fig. 6, the spectra being offset for clarity. It should be remembered that the cut-off of the cube suppression filters prevents observation of the full emission spectrum, particularly for cube H2. The indicated wavelengths of maximum emission are therefore not the true values; the intensity of emission continuing to increase in the hidden portion of the emission spectrum. The true emission spectra for cubes A and H2 may well be identical in shape. As this limitation affects all spectra in the same manner, there should be no adverse effects on the discrimination potential of the method. This limitation was irrelevant to the red disperse dyes examined above, which give little fluorescence emission below 520. nm. In general, the emission intensity obtained with cube A excitation was much

216

Cube A

Cube H2

7io

Wavelength
Fig. 6. Cubes A and H2 fluorescence tification, see Table 1). emission spectra of fluorescent brighteners (for sample iden-

greater than that measured for cube H2. ferences observed between the cubes A and relatively higher values obtained with cube cube A spectra and thus unresolvable. During measurement, it was noted that

This probably accounts for the difH2 spectra at long wavelengths; the H2 being of small magnitude in the the visible intensity of fluorescence

217

emission decayed appreciably during the 2 min needed to complete a measurement. However, this appeared to affect only the intensity of maximum emission and not the reproducibility of the spectral shape. Table 4 summarises the comparison of the fluorescence emission spectra obtained from the fluorescent brighteners examined. Using cube A to provide excitation, only Leucophor EFG can be discriminated from the other samples, by

TABLE 4 DISCRIMINATION Sample no. a OF FLUORESCENT 1


2 3

BRIGHTENERS 4
5

Cube A fluorescence emission spectra (DPb = 400 = 0.40) 0 0 1 0 *** 1 0 *** 1 0 2 1 *** 1 3 0 *** 4 *** 5 Cube A comparison fluorescence microscopy (DP = 4110 0 1 0 *** I *** 1 0 2 *** 1 3 *** 4 5 Cube H2 fluorescence emission spectra 1 *** 1 *** 2 3 4 5 = 0.40) 0 0 1 0 ***

(DP = lo/10 = 1.00) 1 1 1 1 1 1 1 *** 1 1 *** ***

Cube H2 comparison fluorescence microscopy (DP = 9/10 = 0.90) 1 1 1 1 *** 1 0 *** 1 1 2 1 *** 1 3 1 *** 4 *** 5 Visible comparison microscopy (DP = 0110 = 0.00) 0 0 0 *** 1 *** 0 0 2 *** 0 3 +** 4 5 %ee Table 1 for sample identification. bDP, discrimination power. (0) Undiscriminated. (1) Discriminated.

0 0 0 0 ***

218

virtue of the small shoulder present in its spectrum. This leads to an overall discrimination power of 0.4. When cube H2 excitation is employed however, all five samples are differentiated, giving a discrimination power of 1.0. This is achieved mainly by the behaviour in the orange/red area of the fluorescence emission spectra, each sample having a different long wavelength cut-off. For example, with the knitting yarn sample (Baby), the emitted intensity at the red end of the spectrum actually rises considerably. The comparison microscopy results are also presented in Table 4. Visible light illumination provides no discrimination whatsoever, as might be expected. For illumination by cubes A and H2, the respective discrimination powers were 0.4 and 0.9. Table 4 shows that the results of fluorescence microscopy and microspectrofluorimetry for cube A excitation were identical, the same samples being discriminated by each method. For cube H2, the single pairing found identical by fluorescence microscopy could be discriminated by microspectrofluorimetry. Conclusions Even though microspectrofluorimetry is not applicable to all dyestuffs, the results described indicate that it is a valuable additional technique for the discrimination of single textile fibres. Although only tested on a limited range of samples, it appears to be particularly appropriate for use with fluorescent brighteners, for which no simple method of objective comparison currently exists. For cube H2 excitation, microspectrofluorimetry of those red dyestuffs and fluorescent brighteners examined gave higher discrimination powers than both comparison microscopy and microspectrophotometry. The technique is comparable in ease of use to microspectrophotometry and requires no additional equipment above that already found in a forensic science laboratory. Its use is not necessarily limited to fibres; the fluorescent brighteners used in paper may also be discriminated by microspectrofluorimetry. The technique is also capable of extension in two areas. Firstly, it should be possible to code fluorescent colours, using a modification of the CIE system. Secondly, as prolonged excitation causes the fluorescence emission intensity of some dyestuffs to decrease with time, the possibility arises of utilising this feature as a method of discrimination. Both will be examined in subsequent papers. However, as the microspectrofluorimeter used is a scanning instrument, it should be remembered that it is impossible to obtain the true fluorescence emission spectrum of a material which exhibits rapid decay. Although emission intensity at the short wavelengths will be measured correctly, as the scan proceeds, emission at the longer wavelengths will have decayed from its original value. To minimise any irreproducibility, the incident light shutter on the microscope must be used to ensure that excitation and scanning begin simultaneously. The method of microspectrofluorimetry as so far described suffers from one major defect. As the intensity of fluorescence emission is directly proportional to the intensity of the exciting radiation, then the gradual deterioration in output

219

inevitable with the source used will change the intensity of the emission spectrum. Some form of standardisation is therefore indicated. The use of standards in fluorimetry is well documented [17], but most are liquids, which are unsuitable for microspectrofluorimetry. A solid glass microspectrophotometry standard [22]is currently in use in the HOFSS, consisting of a small fragment of purple glass mounted on a slide, which is measured in exactly the same manner as a single fibre. It serves not so much to monitor small changes in the illumination source (which are removed by the use of absorbance or transmission measurements), but more as a check on the correct adjustment and operation of the instrument. The glass used is of course non-fluorescent, which is an important requirement for absorbance standards [23]. However, a similarly constructed standard, made from fluorescent glass, would appear suitable for microspectrofluorimetry. References
1 2 3 4 5 6 R. Macrae, R.J. Dudley and K.W. Smalldon, The characterization of dyestuffs on wool fibers with special reference to microspectrophotometry. J. Forensic Sci., 24 (1979) 117- 129. D.K. Laing and M.D.J. Isaacs, The examination of paints and fibres by microspectrophotometry. W Spectrom. Group Bull., 9 (1981) 18-27. D.K. Laing, A.W. Hartshorne and R.J. Harwood, Colour measurements on single textile fibres. Forensic Sci. Znt., 30 (1986) 65 - 77. A.W. Hartshorne and D.K. Laing, The definition of colour for single textile fibres by microspectrophotometry. Forensic Sci. ht., 34 (1987) 107 - 129. D.K. Laing, A.W. Hartshorne, R. Cook and G. Robinson, A fiber data collection for forensic scientists - collection and examination methods. J. Forensic Sci., 32 (1987) 364 - 369. J.B.F. Lloyd, Forensic significance of fluorescent brighteners: their qualitative TLC characterisation in small quantities of fibre and detergents. J. Forensic Sci. Sot., 17 (1977) 145- 152. K.R. Desai and D.M.Vashi, Thin layer chromatography of some modern optical whitening agents. J. Inst. Chem., Calcutta, 55 (1983) ill- 112. L. Lepri, P.G. Desideri and W. Coas, High performance thin layer chromatography of fluorescent whitening agents and their identification in detergents. J. Chromatogr., 322 (1985) 363 - 370. G. Micah, P. Curro and G. Calabro, High performance liquid chromatographic separation and determination of fluorescent whitening agents in detergents. Analyst, 109 (1984) 155- 158. J.I. Siegel, Fluorescence microscopy. Znt. Lab. 13 (1982) 46-51. CA. Parker, Spectrophosphorimeter microscopy: an extension of fluorescence microscopy. Analyst, 94 (1969) 161- 176. T.A. Kubic, J.E. King and IS. DuBey, Forensic analysis of colorless textile fibres by fluorescence microscopy. Microscope, 31 (1983) 213 - 222. W.G. Hartley, Hartley s Microscopy, Senecio, Charlbury, England, 1979. N.S. Allen, J. Homer and J.F. McKellar, The use of luminescence spectroscopy in aiding the identification of commercial polymers. Analyst, 101 (1976) 260 - 264. G. Wyszecki and W.S. Stiles, Color Science, 2nd edn., Wiley Interscience, New York, 1982. R.S. Hunter, The Measurement ofAppearance, Wiley Interscience, New York, 1975. J.N. Miller (ed)., Standards in Fluorescence Spectrometry, Chapman and Hall, London, 1981. Colour Index International, 3rd edn. (3rd revision), Society of Dyers and Colourists, Bradford, United Kingdom, 1987. R. Cook and D. Norton, An evaluation of mounting media for use in forensic textile fibre examination. J. Forensic Sci. Sot., 22 (1982) 57- 63.

7 8

9 10 11 12 13 14 15 16 17 18 19

220

20 21 22 23

K.W. Smalldon and A.C. Moffat, The calculation of discrimination power for a series of correlated attributes. J. Forensic Sci. See., 13 (1973) 291-295. K. McLaren, The Colour Science ofDyes and Pigments, Adam Hilger, Bristol, United Kingdom, 1983. A.W. Hartshorne and D.K. Laing, An absorption standard for microspectrophotometry: Results of a collaborative exercise. Forensic Sci. Znt., 51 (1991) 263- 271. C. Burgess and A. Knowles (eds.), Standards in Absorption Spectrometry, Chapman and Hall, London. 1981.

Das könnte Ihnen auch gefallen