Beruflich Dokumente
Kultur Dokumente
RC. 413243
Name & Address of the Owner of the Crane OANDO ENERGY SERVICES LTD. Name & Address of the Maker of the Crane EXCELL CRANE AND HYDRAULICS, INC, 3274 WEST MAIN ST, GRAY LA. 70359 USA Type of Crane & Source of Power PEDESTAL CRANE/MECHANICAL & HYDRAULIC POWERED Model No. Pedestal Height from Main Deck
K30-80 Date of last previous Load test of Crane: 01/11/2012
Requested By:
Date of Examination
OLUSEGUN ODUNLAMI
Date of manufacture of Crane OCTOBER 2007 Type of Derricking Interlock SLEW JIB Maker Serial Number
07/10/2013
12FT
Relevant Standard API RP 2D, ISO 4309-1990
K01183
01/11/2012 (i)
Length of jib (feet/mtrs)
Type of inspection:
(ii)
Boom Radius
(iii)
Boom Angle (Degrees)
(iv)
Test Load (Tonne)
(v)
S.W.L(Tonne)
(feet/mtrs)
N/A
N/A
N/A
N/A
N/A
In the case of a crane with a derrick jibs, the maximum angle at which the jib may be worked.
N/A Hydraulic Cylinder Boom (Construction, Size)
Defects noted and alterations and repairs required before the Crane is put into service ( if none enter NONE)
N/A
N/A
(Parts of line) =
SWL
X
6
(Parts of line) =
(Parts of line) =
SWL
INSPECTOR NAME/QUALIFICATTION:
STANLEY IREHIE LEEA, SNT LEVEL II MT, PT, UT, Lifting Equipment Insp.
JC International Ltd.
Page 1 of 10
A)
Inspect, measure wire rope with Venier caliper And record: Construction, Diameter, Type End, Orientation. BOOM LINE a) b) Nominal diameter of Boom Line: Measured Diameter of Boom Line:
Worst percentage of Wear Reduction at Different Section of Boom Line: Maximum Allowable: 10% = Defect which may impair continued use of this wire rope: Overall Assessment: c) d) Installed Date: Wire rope condition: N/A
LOAD LINE e) f) Nominal diameter of Load line: Measured diameter of Load line: 19mm 19mm NONE
Worst percentage of Wear Reduction at different sections of Load line: Maximum Allowable 10% Defect which may impair continued use of this wire rope: Overall Assessment: Installed Date:
g)
Page 2 of 10
JC International Ltd.
AUX. LINE h) i) Nominal diameter of Aux. line: Measured diameter of Aux line: 16mm 16mm
Worst percentage of Wear Reduction at different sections of Aux line: Maximum Allowable 10% = Defect which may impair continued use of this wire rope: Overall Assessment: j) Installed Date:
h)
k) Pendant Line (R ): Installed Date: l) Pendant Line ( L): Installed Date: N/A
B)
CONDITION
COMMENTS
Good
b) Wedge Sockets:
Good
Good
Ok
d) Swivel Condition:
Good
e) Pin Condition:
Good
f)
Good
Page 3 0f 10
JC International Ltd.
g) Main Hoist Block Hook i) Manufacturer: ii) Rating: EXCELL 30 U.S. Tons
h) Sheaves bearings and Bushing: i) Broken Wires None a) Number of Broken wires in one strand: b) Number of Broken wires in one lay: c) Numbers of Broken wires at the end fitting: None None None
C 1.
WIRE ROPE WINCH DRUMS Main Line Hoist Drum a) Rope Properly Reeved:
CONDITION
COMMENTS
Yes
Good
Good
Yes
JC International Ltd.
3.
b)
D.
CONDITION
COMMENTS
Good
Good
c) Boom Length:
80ft
d) Condition of Pins/keeper/Bolts:
Good
No wear on pins and And foot pin secured Cuts operation once at limit
e) Boom Stop:
Good
f)
Number of Sections:
Good N/A
i)
N/A
j)
Boom Pendant connection point condition: N/A Good Cuts operation once at limit
l)
Good
Page 5 0f 10
JC International Ltd.
m)
Sheave condition:
Good
E.
a) Housing condition:
Good
Handrails, Midrails, toe board and floors are all structurally good.
Good
Good
Non-slip surface, Platforms and railings are properly in order In good condition
Handrail, midrails, And floors are all Structurally good
Good
e) f) F.
Good Good Safe, clear of Obstruction and built To standard Proper markings and operations. Controllers labeled to indicate their functions Working properly Working properly Working properly
c)
Page 6 of 10
JC International Ltd.
e)
Yes
Proper markings
f)
Good
g)
Good
G a)
BRAKES Main Hydraulic hoist brake system: Good Stops operation after Brake application Stops operation after Brake application
b)
Good
c)
Good
d)
Good
e)
Swing Ring: Slewing ring condition: Slew ring motor: Good Good
CONDITION
COMMENTS
a)
Not seen
Good
Good
Good
Page 7 of 10
JC International Ltd.
e) Control identification:
Good
f)
Good
N/A
h) Fire Extinguisher:
Good
In operators cabin
i)
Load Indicator
Bad
CONDITION Good
COMMENT
b)
Access ladders/step:
Good
Page 8 of 10
JC International Ltd.
JC International Limited
RC. 413243
Page 9 of 10
JC International Ltd.
JC International Limited
RC. 413243
GENERAL
Inspect the following: a) Hydraulic Swivel: CONDITIONS Good
b)
Good
c)
Safety System:
Good
d) e)
N/A Good
f)
Angle Indicator:
Good
g)
Load Indicator:
Bad
h)
Good
i)
Load Chart:
Good
j)
Control Identification:
Good
k)
Fire Extinguishers:
Good
l)
Good
m)
Cabin Condition:
Good
n)
Good
o)
Good
p)
Sheave
Good
Page 10 0f 10
JC International Ltd.