Beruflich Dokumente
Kultur Dokumente
Stupidcaterpillar
Entries (RSS) Comments (RSS) Home RF Parametric RF performance Protocols Message Type in IE RRC Reporting events
Timers for UE
Timer T300 Start Stop At expiry
T302
T304
Retransmit RRC CONNECTION REQUEST if V300 =< N300, else go to Idle mode Transmission of Reception of CELL Retransmit CELL CELL UPDATE UPDATE/URA UPDATE/URA CONFIRM/URA UPDATE if V302 =< UPDATE UPDATE CONFIRM N302, else, go to Idle mode Transmission of Reception of UE Retransmit UE UE CAPABILITY CAPABILITY CAPABILITY INFORMATION INFORMATION if INFORMATION CONFIRM V304 =< N304, else initiate a cell update procedure
1/7
http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/
2/1/2014
T305
Entering Entering another state. CELL_FACH or URA_PCH or CELL_PCH state. Reception of CELL UDPATE CONFIRM/URA UPDATE CONFIRM. When the timer When the UE detects T305 has expired in service area. and the UE detects out of service area. Transmission of Not stopped RRC CONNECTION RELEASE COMPLETE
Transmit CELL UPDATE if T307 is not activated and the UE detects in service area. Otherwise, if T307 is not active, start T307.
T307
T308
T309
T310
T311
T312
Transmit RRC CONNECTION RELEASE COMPLETE if V308 <=N308, else go to idle mode. Upon reception of Successful response to Resume the connection CELL CHANGE a connection to UTRAN ORDER FROM establishment request in UTRAN message the new cell. Transmission of Reception of Transmit PUSCH PUSCH PHYSICAL SHARED CAPACITY CAPACITY CHANNEL REQUEST if V310 =< REQUEST ALLOCATION N310, else procedure stops. Reception of Reception of UE may initiate a PHYSICAL PHYSICAL SHARED PUSCH capacity SHARED CHANNEL request procedure. CHANNEL ALLOCATION ALLOCATION message with message with the CHOICE PUSCH CHOICE allocation set to PUSCH PUSCH allocation allocation set to assignment. PUSCH allocation pending. When the UE When the UE detects The criteria for physical starts to establish N312 in sync channel establishment dedicated CH indication from L1. failure is fulfilled
2/7
http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/
2/1/2014
T313
When the UE detects consecutive N313 out of sync indication from L1.
When the UE detects The criteria for Radio consecutive N315 in Link failure is fulfilled sync indication from L1.
T314
When the criteria When the Cell Update See subclause 8.3.1.13 for radio link procedure has been failure are fulfilled. completed. The timer is started if radio bearer(s) that are associated with T314 exist of if only RRC connection exists.
T315
When the criteria When the Cell Update See subclause 8.3.1.14 for radio link procedure has been failure are fulfilled. completed. The timer is started only if radio bearer(s) that are associated with T315 exist.
T316
When the UE When the UE detects detects out of in service area. service area in URA_PCH or CELL_PCH state
T317
Initiate cell update procedure if in service area is detected. Otherwise start timer T317, transit to CELL_FACH state and initiate cell update procedure when the UE detects in service area. When the T316 When the UE detects Transit to idle mode expires or when in in service area. CELL_FACH state, the UE detects out of service area.
3/7
http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/
2/1/2014
Counters for UE
Counter Reset V300 When reaching max value When initiating the Upon expiry of T300. When V300 > N300, procedure RRC the UE enters idle connection mode. establishment When initiating the Upon expiry of T302 When V302 > N302 procedure Cell the UE enters idle update or URA mode. update When sending the Upon expiry of T304 When V304 > N304 first UE the UE initiates the Cell CAPABILITY update procedure INFORMATION message. When sending the Upon expiry of T308 When V308 > N308 first RRC the UE stops reCONNECTION transmitting the RRC RELEASE CONNECTION COMPLETE RELEASE message in a RRC COMPLETE message. connection release procedure. When sending the Upon expiry of T310 When V310 > N310 first PUSCH the UE stops reCAPACITY transmitting the REQUEST PUSCH CAPACITY message in a REQUEST message. PUSCH capacity request procedure Incremented
V302
V304
V308
V310
http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/
2/1/2014
CONNECTION RELEASE COMPLETE message Maximum number of retransmission of the PUSCH CAPACITY REQUEST message Maximum number of in sync received from L1. Maximum number of successive out of sync received from L1. Maximum number of successive in sync received from L1 during T313 is activated.
You are commenting using your WordPress.com account. ( Log Out / Change )
You are commenting using your Twitter account. ( Log Out / Change )
You are commenting using your Facebook account. ( Log Out / Change )
http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/ 5/7
2/1/2014
You are commenting using your Google+ account. ( Log Out / Change ) Cancel Connecting to %s Notify me of follow-up comments via email.
Post Comment
Search
Cause codes from network. RSCP & Ec/Io Cause values for mobility management Timers of mobility management Cause values for GPRS Session Management 3G UE Protocol timers, counters, other parameters and default configurations RF Parametric PLMN selection and roaming Automatic Network Selection Mode Procedure Cause values for call control aamadmi: Great Job done ! for a one stop source for references of relevant timers. Idriss: Hi, it is very interessent, but i need know if the measuse is tooken for a special code or for the best signal code of a node B?? J: Hello, I'm trying to find a bit more information regarding GMM cause 98 however I don't quite understand the, "see annex.H subclause H.6.2". I would
Categories
BMC (1) NAS (6) Network Selection by UE (2) Physical Layer (1)
http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/ 6/7
2/1/2014
Archives
July 2011 February 2011 October 2010 September 2010 August 2010 Blog at WordPress.com. The Albeo Theme. Follow
Follow Stupidcaterpillar
Get every new post delivered to your Inbox.
Enter your email address Sign me up
Powered by WordPress.com
http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/