Timers for UE
Timer T300 Start Stop At expiry

Transmission of Reception of RRC RRC CONNECTION CONNECTION SETUP REQUEST

T302

T304

Retransmit RRC CONNECTION REQUEST if V300 =< N300, else go to Idle mode Transmission of Reception of CELL Retransmit CELL CELL UPDATE UPDATE/URA UPDATE/URA CONFIRM/URA UPDATE if V302 =< UPDATE UPDATE CONFIRM N302, else, go to Idle mode Transmission of Reception of UE Retransmit UE UE CAPABILITY CAPABILITY CAPABILITY INFORMATION INFORMATION if INFORMATION CONFIRM V304 =< N304, else initiate a cell update procedure
1/7

http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/

2/1/2014

3G UE Protocol timers, counters, other parameters and default configurations | Stupidcaterpillar

T305

Entering Entering another state. CELL_FACH or URA_PCH or CELL_PCH state. Reception of CELL UDPATE CONFIRM/URA UPDATE CONFIRM. When the timer When the UE detects T305 has expired in service area. and the UE detects out of service area. Transmission of Not stopped RRC CONNECTION RELEASE COMPLETE

Transmit CELL UPDATE if T307 is not activated and the UE detects in service area. Otherwise, if T307 is not active, start T307.

T307

Transit to idle mode

T308

T309

T310

T311

T312

Transmit RRC CONNECTION RELEASE COMPLETE if V308 <=N308, else go to idle mode. Upon reception of Successful response to Resume the connection CELL CHANGE a connection to UTRAN ORDER FROM establishment request in UTRAN message the new cell. Transmission of Reception of Transmit PUSCH PUSCH PHYSICAL SHARED CAPACITY CAPACITY CHANNEL REQUEST if V310 =< REQUEST ALLOCATION N310, else procedure stops. Reception of Reception of UE may initiate a PHYSICAL PHYSICAL SHARED PUSCH capacity SHARED CHANNEL request procedure. CHANNEL ALLOCATION ALLOCATION message with message with the CHOICE PUSCH CHOICE allocation set to PUSCH PUSCH allocation allocation set to assignment. PUSCH allocation pending. When the UE When the UE detects The criteria for physical starts to establish N312 in sync channel establishment dedicated CH indication from L1. failure is fulfilled
2/7

http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/

2/1/2014

3G UE Protocol timers, counters, other parameters and default configurations | Stupidcaterpillar

T313

When the UE detects consecutive N313 out of sync indication from L1.

When the UE detects The criteria for Radio consecutive N315 in Link failure is fulfilled sync indication from L1.

T314

When the criteria When the Cell Update See subclause 8.3.1.13 for radio link procedure has been failure are fulfilled. completed. The timer is started if radio bearer(s) that are associated with T314 exist of if only RRC connection exists.

T315

When the criteria When the Cell Update See subclause 8.3.1.14 for radio link procedure has been failure are fulfilled. completed. The timer is started only if radio bearer(s) that are associated with T315 exist.

T316

When the UE When the UE detects detects out of in service area. service area in URA_PCH or CELL_PCH state

T317

Initiate cell update procedure if in service area is detected. Otherwise start timer T317, transit to CELL_FACH state and initiate cell update procedure when the UE detects in service area. When the T316 When the UE detects Transit to idle mode expires or when in in service area. CELL_FACH state, the UE detects out of service area.
3/7

http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/

2/1/2014

3G UE Protocol timers, counters, other parameters and default configurations | Stupidcaterpillar

Counters for UE
Counter Reset V300 When reaching max value When initiating the Upon expiry of T300. When V300 > N300, procedure RRC the UE enters idle connection mode. establishment When initiating the Upon expiry of T302 When V302 > N302 procedure Cell the UE enters idle update or URA mode. update When sending the Upon expiry of T304 When V304 > N304 first UE the UE initiates the Cell CAPABILITY update procedure INFORMATION message. When sending the Upon expiry of T308 When V308 > N308 first RRC the UE stops reCONNECTION transmitting the RRC RELEASE CONNECTION COMPLETE RELEASE message in a RRC COMPLETE message. connection release procedure. When sending the Upon expiry of T310 When V310 > N310 first PUSCH the UE stops reCAPACITY transmitting the REQUEST PUSCH CAPACITY message in a REQUEST message. PUSCH capacity request procedure Incremented

V302

V304

V308

V310

UE constants and parameters


Constant N300 N302 N304 N308 Usage Maximum number of retransmissions of the RRC CONNECTION REQUEST message Maximum number of retransmissions of the CELL UPDATE / URA UPDATE message Maximum number of retransmissions of the UE CAPABILITY INFORMATION message Maximum number of retransmissions of the RRC
4/7

http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/

2/1/2014

3G UE Protocol timers, counters, other parameters and default configurations | Stupidcaterpillar

N310 N312 N313 N315

CONNECTION RELEASE COMPLETE message Maximum number of retransmission of the PUSCH CAPACITY REQUEST message Maximum number of in sync received from L1. Maximum number of successive out of sync received from L1. Maximum number of successive in sync received from L1 during T313 is activated.

Related Leave a Reply


Enter your comment here...

Fill in your details below or click an icon to log in:

Email (required) (Address never made public) Name (required) Website

You are commenting using your WordPress.com account. ( Log Out / Change )

You are commenting using your Twitter account. ( Log Out / Change )

You are commenting using your Facebook account. ( Log Out / Change )
http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/ 5/7

2/1/2014

3G UE Protocol timers, counters, other parameters and default configurations | Stupidcaterpillar

You are commenting using your Google+ account. ( Log Out / Change ) Cancel Connecting to %s Notify me of follow-up comments via email.
Post Comment

Search

Top Posts Latest Comments Tags

Cause codes from network. RSCP & Ec/Io Cause values for mobility management Timers of mobility management Cause values for GPRS Session Management 3G UE Protocol timers, counters, other parameters and default configurations RF Parametric PLMN selection and roaming Automatic Network Selection Mode Procedure Cause values for call control aamadmi: Great Job done ! for a one stop source for references of relevant timers. Idriss: Hi, it is very interessent, but i need know if the measuse is tooken for a special code or for the best signal code of a node B?? J: Hello, I'm trying to find a bit more information regarding GMM cause 98 however I don't quite understand the, "see annex.H subclause H.6.2". I would

Categories
BMC (1) NAS (6) Network Selection by UE (2) Physical Layer (1)
http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/ 6/7

2/1/2014

3G UE Protocol timers, counters, other parameters and default configurations | Stupidcaterpillar

RF (1) RRC (2)

Archives
July 2011 February 2011 October 2010 September 2010 August 2010 Blog at WordPress.com. The Albeo Theme. Follow

Follow Stupidcaterpillar
Get every new post delivered to your Inbox.
Enter your email address Sign me up

Powered by WordPress.com

http://stupidcaterpillar.wordpress.com/2010/09/08/3g-ue-protocol-timers-counters-other-parameters-and-default-configurations/

7/7

Das könnte Ihnen auch gefallen