DESCRIPTION
HYDROTITE CJ-0725 is a state-of-the-art hydrophilic waterstop. Comprised of non-bentonite synthetic chloroprene rubber, HYDROTITE has unmatched durability and water sealing capacity. Expanding when exposed to water, HYDROTITE conforms to gap variations along the joint. The swelling action combined with HYDROTITEs co-extrusion ensures complete sealing even under high hydrostatic head pressures. Due to its slim profile, excellent concrete consolidation can be expected around the waterstop, with little chance of the profile being moved out of position when concrete is placed. The small cross section allows most CJ profiles to be packaged in convenient 10 meter rolls weighing less than 3 kilograms. HYDROTITE CJ profiles, as well as all HYDROTITE profiles, are treated with a special delay coating to prevent it from reacting with fresh, moist concrete and expanding before curing takes place. HYDROTITE CJ-0725 is glued to a concrete footing during the construction of a new potable water reservoir
FEATURES
delay coating to prevent premature swelling co-extruded to create directional growth no difficult split forming required fast, simple and economical to install resistant to common chemicals and microbacterial attack proven track record
APPLICATION
HYDROTITE CJ-0725 is designed for sealing construction joints in new concrete structures such as: potable water reservoirs utility chambers swimming pools cast-in-place transit tunnels sewage treatment facilities parking garages bridges hydro dams HYDROTITE CJ-0725 is glued and fastened prior to the placement of a concrete traffic overlay on a large bridge rehabilitation
HYDROPHILIC WATER SEALING MATERIALS
HYDROTITE CJ-0725 is commonly installed as a waterstop between new and existing structures during facility expansion projects. Large concrete refacing and rehabilitation projects benefit from the ease of installation of HYDROTITE.
HYDROPHILIC
WATER
SEALING
MATERIALS
HYDROPHILIC
WATER
SEALING
CONCRETE WALL
2. Forming Requirements: HYDROTITE CJ profiles are installed after the form is stripped from the first pour and before the second concrete pour is made. Therefore, splitting the form is not required. Due to the hydrophilic nature of the HYDROTITE product, installation of the profile should be timed as close as possible to the second placement of concrete. This will reduce the chance for premature expansion of HYDROTITE due to rain water or ground water exposure. 3. HYDROTITE / PVC Junctions: HYDROTITE CJ profiles are commonly used in conjunction with typical PVC waterstops. HYDROTITE CJ profiles should be cut to butt up directly to the PVC. Place several drops of a cyanacrylate type adhesive (super-glue) to the PVC and the cut end of HYDROTITE and immediately join the ends together. Hold in position for approximately 30 seconds to allow the adhesive to set. Apply a sufficient bead of LEAKMASTER to the HYDROTITE / PVC junction. HYDROTITE CJ-0725 and LEAKMASTER are used during many concrete rehabilitation projects
HYDROTITE CJ-0725
HYDROTITE CJ-0725
HYDROTITE CJ-0725
LEAKMASTER
ADHESIVE
NAIL
HYDROPHILIC
WATER
SEALING
MATERIALS
HYDROPHILIC
NOTE: In all 3 installation methods, installed HYDROTITE profiles should be inspected to ensure that no separation exists between the HYDROTITE profile and the substrate. If this is observed, apply a suitable bead of LEAKMASTER in the separation and secure with nails or special fasteners as required.
WATER
A 2-part epoxy may also be used to level extremely erratic surfaces. MULTIURETHANES GEL-LOC EPOXY can be used on rough, damp concrete surfaces to bond HYDROTITE profiles in position. The HYDROTITE profile should be applied to the bed of epoxy prior to final cure, approximately 30 minutes. Again, concrete nails may be used on vertical or overhead applications.
SEALING
MATERIALS
HYDROPHILIC
WATER
SEALING
MATERIALS
10
50 mm
6. Important Precautions:
BEND TO RADIUS
CJ CAN BE BENT TO A MINIMUM RADIUS OF APPROX. 50 mm OTHERWISE MITER AND BOND WITH SUPER-GLUE
Cracking of the concrete, caused by the expansion pressure of HYDROTITE, can be avoided by maintaining a 50 mm minimum concrete coverage. Increase this coverage if lightweight or low strength concrete (<25 mPa compressive strength) is used. Appropriate concrete placement techniques must be implemented to ensure proper concrete consolidation. HYDROTITE should be stored in a cool, dark, dry place. Exposure to moisture prior to installation may expand HYDROTITE prematurely. If HYDROTITE is installed in an expanded condition, the effectiveness of the seal may be severely reduced. Once installed, adequate measures should be taken to prevent exposure to rain water, ground water, etc. before the joint is covered with concrete.
Flat Ts and Xs should be made by butt slicing and joining the legs with the use of cyanacrylate adhesive. Vertical 90 corner, vertical Ts and vertical Xs should be butted and bonded with the cyanacrylate adhesive. MULTIURETHANES offers contractors prefabricated and spliced components. NOTE: All splices must be further enhanced by placing a bead of LEAKMASTER at the splice.
PACKAGING
CJ-0725 is packaged in boxes containing 6 x 10 m rolls.