Sie sind auf Seite 1von 7

Company name: Created by: Phone: Fax: Date: 10/8/2013

Position Qty. Description Single Price

CR 20-5 A-F-A-E-HQQE

Price on request

Note! Product picture may differ from actual product

Product No.: 96504450 Vertical, non-self-priming, multistage, in-line, centrifugal pump for installation in pipe systems and mounting on a foundation. The pump has the following characteristics: - Impellers and intermediate chambers are made of Stainless steel, DIN W.-Nr. 1.4301. - Pump head and base are made of Cast iron. - The shaft seal has assembly length according to EN 12756. - Power transmission is via cast iron split coupling. - Pipework connection is via DIN flanges. The motor is a 3-phase AC motor.

Liquid: Liquid temperature range: Density: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Materials: Pump housing:

-20 .. 120 C 1000 kg/m

3529 rpm 25.3 m/h 85.2 m HQQE CE

Impeller:

Cast iron EN-JL1030 ASTM A48-30 B Stainless steel DIN W.-Nr. 1.4301 AISI 304

Installation: Maximum ambient temperature: 60 C Max pressure at stated temp: 16 bar / 120 C 16 bar / -20 C Flange standard: DIN Pipe connection: DN 50 Pressure stage: PN 16
Printed from Grundfos CAPS [2012.01.059]

1/7

Company name: Created by: Phone: Fax: Date: 10/8/2013


Position Qty. Description Single Price

Flange size for motor: Electrical data: Motor type: IE Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump: Mains frequency: Rated voltage: Rated current: Starting current: Cos phi - power factor: Rated speed: IE efficiency: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85):

FF300

160MB IE2 - IE3 2 11 kW 11 kW 11 kW 60 Hz 3 x 380-480 D/660-690 Y V 20,8-17,2/12,0-11,6 A 580-890 % 0,89-0,83 3520-3550 rpm IE2 90,2% - IE3 91,0% 90,2-91,0 % 91,1-91,4 % 91,2-90,3 % 55 (Protect. water jets/dust) F

Others: Net weight: Gross weight: Shipping volume:

141 kg 169 kg 0.56 m3

Printed from Grundfos CAPS [2012.01.059]

2/7

Company name: Created by: Phone: Fax: Date: 10/8/2013


Description Product name: Product No: EAN number: Technical: Speed for pump data Rated flow: Rated head: Head max: Impellers: Shaft seal: Approvals on nameplate: Stages: Pump version: Model: Materials: Pump housing: Value CR 20-5 A-F-A-E-HQQE 96504450 5700396290416 H (m) 90 80 70 60 50 40 30 20 10 0 0 P (kW) 8 6 4 2 0
204 314

CR 20-5 3* 440 V, 60 Hz Density = 1000 kg/m

eta (%)

3529 rpm 25.3 m/h 85.2 m 106 m 05 HQQE CE 05 A A

80 60 40 20 0 NPSH (m) P1 P2 8 6 4 2 0

10

15

20

25

30 Q(m/h)

Impeller:

Material code: Code for rubber: Installation: Maximum ambient temperature: Max pressure at stated temp Flange standard: Connect code: Pipe connection: Pressure stage: Flange size for motor: Liquid: Liquid temperature range Density: Electrical data: Motor type: IE Efficiency class: Number of poles: Rated power - P2: Power (P2) required by pump Mains frequency: Rated voltage: Rated current: Starting current Cos phi - power factor: Rated speed: IE efficiency: Motor efficiency at full load: Motor efficiency at 3/4 load: Motor efficiency at 1/2 load: Enclosure class (IEC 34-5): Insulation class (IEC 85): Motor protec: Motor No: Others: Net weight: Gross weight: Shipping volume:

Cast iron EN-JL1030 ASTM A48-30 B Stainless steel DIN W.-Nr. 1.4301 AISI 304 A E

60 C 16 bar / 120 C 16 bar / -20 C DIN F DN 50 PN 16 FF300

471

352 G 1/2 G 1/2

-20 .. 120 C 1000 kg/m

664

G 1/2

18.1 125 65 215 256


CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE THERMISTORS PTC ACCORDING TO DIN 44082

160MB IE2 - IE3 2 11 kW 11 kW 11 kW 60 Hz 3 x 380-480 D/660-690 Y V 20,8-17,2/12,0-11,6 A 580-890 % 0,89-0,83 3520-3550 rpm IE2 90,2% - IE3 91,0% 90,2-91,0 % 91,1-91,4 % 91,2-90,3 % 55 (Protect. water jets/dust) F PTC 85U17524

90

130 176 300

4 x 13.5

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

+T

+T

+T

141 kg 169 kg 0.56 m3

TO AMPLIFIER RELAY

L1

L2

L3

Printed from Grundfos CAPS [2012.01.059]

3/7

165

20

Company name: Created by: Phone: Fax: Date: 10/8/2013

96504450 CR 20-5 60 Hz
H (m) CR 20-5 3* 440 V, 60 Hz eta Density = 1000 kg/m (%)

100

90

80

70

60

50

40

80 70

30

60 50

20

40 30

10

20 10

0 0 P (kW)

10

15

20

25

30

Q(m/h)

0 NPSH (m)

10 8 6 4 2 0
Printed from Grundfos CAPS [2012.01.059]

P1 P2

10 8 6 4 2 0

4/7

Company name: Created by: Phone: Fax: Date: 10/8/2013

96504450 CR 20-5 60 Hz
cos phi eta 1 eta cos phi 0.8 40 CR 20-5 + 160MB 11 kW 3* 440 V, 60 Hz I (A) 50

0.6

30

I 0.4 20

0.2

10

0 0 n (rpm)

10

12

14

P2(kW) P1 n

0 P1 (kW)

3200

12

2800

2400

0
Printed from Grundfos CAPS [2012.01.059]

5/7

Company name: Created by: Phone: Fax: Date: 10/8/2013

96504450 CR 20-5 60 Hz

204 314

471

352 G 1/2 G 1/2

664

G 1/2

18.1 125 65 215 256 165

90

20

130 176 300

4 x 13.5

Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. Printed from Grundfos CAPS [2012.01.059]

6/7

Company name: Created by: Phone: Fax: Date: 10/8/2013

96504450 CR 20-5 60 Hz

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

+T

+T

+T

TO AMPLIFIER RELAY

L1

L2

L3

Note! All units are in [mm] unless others are stated. Printed from Grundfos CAPS [2012.01.059]

7/7

IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 44082