Sie sind auf Seite 1von 2

Masonry Column

Lic. # : KW-06004882 Design of Masonry Pilaster at Canopy Location - Handicap Ramp Description :

File = C:\PROGRA~2\ENERCA~1 ENERCALC, INC. 1983-2012, Build:6.12.12.7, Ver:6.12.12.7

Licensee : mwh engineering

Code References
Calculations per, ASCE 7-05 Load Combinations Used : ASCE 7-05

General Information
Material Properties Column Data F'm = 1,500.0 psi Column width along X-X = 75.0 psi Fr - Rupture = Column depth along Y-Y = Em = f'm * = 1,125.0 Longitudinal Bar Size = 120.0 pcf Column Density = Bars per side at +Y & -Y = Rebar Grade = Grade 60 Bars per side at +X & -X = 60000 psi Fy - Yield = Cover from ties = 24000 psi Fs - Allowable = Actual Edge to Bar Center = E - Rebar = 29,000.0 ksi Load Combination = ASCE 7-05 Brace condition for deflection (buckling) along columns : 23.625 in 23.625 in # 7.0 3 3 3.50 in 4.4375 in Analysis Settings Analysis Method End Fixity Condition Overall Column Height Construction Type Tie Bar Size Tie Bar Spacing = Working Stress Design

= Top Pinned, Bottom Fixed = 7.110 ft Solid Grouted Hollow Concrete Masonry = =

4.0 8.0 in

X-X (width) axis : Y-Y (depth) axis :

Unbraced Length for X-X Axis buckling = 7.110 ft, K = 0.80 Unbraced Length for X-X Axis buckling = 7.110 ft, K = 0.80

Service loads entered. Load Factors will be applied for calculations. . Applied Loads Column self weight included : 3,306.98 lbs * Dead Load Factor AXIAL LOADS . . . Axial Load at 7.110 ft, D = 2.804 k BENDING LOADS . . . Moment fron STL Column due to wind: Moment acting about Y-Y axis, W = 33.145 k-ft . DESIGN SUMMARY

Bending & Shear Check Results PASS Maximum Bending Stress Ratio =
Load Combination Location of max.above base At maximum location values are . . . Axial - Applied Axial - Allowable Moment - Applied Moment - Allowable

0.901 : 1
+0.60D+W+H 7.062 ft 3.667 k 4.075 k 32.811 k-ft 36.423 k-ft 4.800 1.395 22.326

Maximum SERVICE Load Reactions . . Top along X-X 6.993 k Bottom along X-X 6.993 k

Maximum SERVICE Load Deflections . . . Along x-x 0.002 in for load combination : W Only

at

4.772 ft

above base

PASS

Reinforcing Area Check


As : Actual Reinforcement Min: 0.0025 * An Max: 0.04 * An

Compressive Strength 280.943 k Pa = (0.25 f'm An + 0.65 Ast Fs) * [1-(h/(140*r))^2]

PASS Check Column Ties


Min. Tie Dia. = 1/4", # 4 bar provided Max Tie Spacing = 14.00 in, Provided = 8.00 in

Dimensional Checks PASS


Min. Width/Depth >= 8" Overall Height / Min Dim <= 25

Load Combination Results Load Combination


D Only +D+L+H +D+W+H +D+0.750Lr+0.750L+0.750W+H +D+0.750L+0.750S+0.750W+H +0.60D+W+H Maximum Bending Stress Ratios Stress Ratio Status Location 0.02169 PASS 0.0 ft 0.02169 PASS 0.0 ft 0.8522 PASS 7.062 ft 0.6080 PASS 7.062 ft 0.6080 PASS 7.062 ft 0.9008 PASS 7.062 ft Maximum Axial Load Actual Allow 6.111 k 280.937 6.111 k 280.937 6.111 k 7.188 6.111 k 10.146 6.111 k 10.146 3.667 k 4.075 Maximum Moments Actual Allow 0.0 k-ft 22.007 k-ft 0.0 k-ft 22.007 k-ft 32.811 k-ft 38.497 k-ft 24.609 k-ft 40.449 k-ft 24.609 k-ft 40.449 k-ft 32.811 k-ft 36.423 k-ft

k k k k k k

Masonry Column
Lic. # : KW-06004882 Design of Masonry Pilaster at Canopy Location - Handicap Ramp Description :

File = C:\PROGRA~2\ENERCA~1 ENERCALC, INC. 1983-2012, Build:6.12.12.7, Ver:6.12.12.7

Licensee : mwh engineering

Maximum Reactions - Unfactored


Load Combination D Only W Only D+W Load Combination D Only W Only D+W Y-Y Axis Reaction @ Base @ Top k 6.993 k 6.993 k Max. Y-Y Deflection 0.0000 in 0.0024 in 0.0024 in k -6.993 k -6.993 k Distance 0.000 ft 4.772 ft 4.772 ft

Note: Only non-zero reactions are listed. Axial Reaction @ Base 6.111 k k 6.111 k

Maximum Deflections for Load Combinations - Unfactored Loads

Cross Section
Bar Spac = 7.375 in Y

Interaction Diagram
Masonry Column P-M Interaction Diagram
199.7 Allowable Moment (k-ft) Min. Ecc = 0.10 * Depth

. .

Pa - Allowable = 199.73
179.8

159.8
23.625 in

X
Bar Spac = 7.375 in

Compression Zone

139.8
No Rebar Tension

Balanced Pb, Mb = (114.93, 65.85)


Bar Size = # 7.0

99.9

3.50 in

79.9
23.625 in

59.9
Tension Zone

39.9

20.0

Mmax w/ Pu = 0 = 33.77
6.9 13.8 20.7 27.7 34.6 41.5 48.4 55.3 62.2 69.1

Allowable Axial (k)

119.8

Das könnte Ihnen auch gefallen