Evacuated tube solar heat pipe collector model and associated tests

Farzad Jafarkazemi and Hossein Abdi Citation: J. Renewable Sustainable Energy 4, 023101 (2012); doi: 10.1063/1.3690958 View online: http://dx.doi.org/10.1063/1.3690958 View Table of Contents: http://jrse.aip.org/resource/1/JRSEBH/v4/i2 Published by the American Institute of Physics.

Related Articles
Theoretical and experimental investigation of Alfa type bio mass Stirling engine with effect of regenerator effectiveness, heat transfer, and properties of working fluid J. Renewable Sustainable Energy 4, 043126 (2012) Performance analysis and parametric optimum criteria of the nanothermoelectric engine with a single-level quantum dot at maximum power J. Appl. Phys. 111, 094318 (2012) Optimization of power and efficiency of thermoelectric devices with asymmetric thermal contacts J. Appl. Phys. 111, 024509 (2012) Performance of copper coated two stroke spark ignition engine with methanol-blended gasoline with catalytic converter J. Renewable Sustainable Energy 4, 013102 (2012) A high performance thermoacoustic engine J. Appl. Phys. 110, 093519 (2011)

Additional information on J. Renewable Sustainable Energy


Journal Homepage: http://jrse.aip.org/ Journal Information: http://jrse.aip.org/about/about_the_journal Top downloads: http://jrse.aip.org/features/most_downloaded Information for Authors: http://jrse.aip.org/authors

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY 4, 023101 (2012)

Evacuated tube solar heat pipe collector model and associated tests
Farzad Jafarkazemia) and Hossein Abdib)
Department of Mechanical Engineering, South Tehran Branch, Islamic Azad University, P.O. Box 1584743311, Tehran, Iran (Received 10 December 2011; accepted 8 February 2012; published online 6 March 2012)

In this paper, an evacuated solar heat pipe collector is investigated theoretically and experimentally. Heat transfer formulas were used for theoretical modeling, and a test method was adopted from ISO 9806-1 to compare the theoretical model with the experimental results. The collector efciency and useful heat gain were compared between the theoretical and experimental methods. The effect of the working uid ow rates and collector area were also investigated and discussed. The comparison shows that the theoretical model is in good agreement with the experimental results and is capable of predicting the efciency, useful heat gain, and working uid outlet temperature of an evacuated heat pipe collector with good accuracy. C 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3690958] V
I. INTRODUCTION

Currently, most of the global energy demand is met by fossil fuels, but the massive exploitation of fossil fuels leads to a real threat to the environment from global warming and acidication of the water cycle. Rapidly increasing energy requirements, reduced availability of traditional sources of energy, and environmental pollution have forced scientists to search for alternative energy sources. Sun and wind are among those energy resources that are effectively unlimited and are available in abundant amounts and all over the world at no cost. The average solar irradiation for the whole of Iran is approximately 5.3 kWh per square meter per day, and it is even higher in the central part of the country. The amount of useful solar radiation hours in Iran exceeds 2800 h per year.1 To convert the solar radiation energy into a more usable or storable form, solar collectors are used. These devices constitute the core of solar heating systems and are available in different forms and designs. Evacuated solar heat pipe collectors represent a novel design concept that has a low loss coefcient. The literature contains studies on evacuated and heat pipe solar collectors and the effect of different parameters on their performance. Mahdjuri2 rst introduced a tubular evacuated solar collector with rectangular performance characteristics. He introduced a heat pipe cycle to transfer heat from the absorber to the water tubing. Ortabasi and Fehlner3 used a solar thermal heat pipe collector based on an internal cusp concentrator. The performance of the collector was compared to that of an evacuated, selectively coated at-plate absorber equipped with owthrough heat transfer. Garg et al.4 have discussed the state of the art for evacuated tubular solar energy collectors. They have also attempted to analyze the optical and thermal behavior of this evacuated collector. Ezekwe5 employed a mathematical model to analyze and compare solar energy systems that use heat pipe absorbers with systems that use conventional solar collectors. Zambolin and Del Col6 and Fischer et al.7 tested different collectors with standard testing methods, such as EN, ISO, and ASHRAE. EN 12975-2 (Ref. 8) standard is the latest standard in these series. Ng et al.9 conducted performance tests under steady state conditions for two types
a)

b)

Author to whom correspondence should be addressed. Electronic mail: f_jafarkazemi@azad.ac.ir. Tel.: 0098(912) 3499232. Fax: 0098(21)66572717. Electronic mail: abdi@mech.ir. 4, 023101-1
C 2012 American Institute of Physics V

1941-7012/2012/4(2)/023101/13/$30.00

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-2

F. Jafarkazemi and H. Abdi

J. Renewable Sustainable Energy 4, 023101 (2012)

of evacuated tube solar heat pipe collectors. A theoretical model was also presented to predict the collector efciency. Azad10 designed and constructed a heat pipe solar collector and measured its performance in an outdoor test facility. The thermal behavior was investigated theoretically and experimentally. The theoretical model was based on the effectiveness-NTU method. Ayompe et al.11 presented year-round energy performance monitoring results for two solar water heaters (SWHs) with at plate and heat pipe evacuated tube collectors (ETCs). The energy performance of the two systems was compared on a daily, monthly, and yearly basis. Hayek et al.12 conducted an experimental investigation of the overall performance of two kinds of evacuated tube solar collectors, specically, the water-in-glass tube and the heat-pipe designs. Jafarkazemi et al.13 reviewed the international standards for determining the thermal performance of solar thermal collectors and solar water heating systems and introduced the details of a test center which was under construction in Iran. Badar et al.14 investigated the overall heat loss coefcient (U-value) of a vacuum tube solar collector experimentally and theoretically with regard to the pressure of the remaining gas inside the evacuated glass envelope. Tang et al.15 constructed and tested two sets of water-in-glass evacuated tube SWH for performance comparative study. Both SWHs were identical in all aspects but had different collector tilt-angle from the horizon with the one inclined at 22 and the other at 46 . Zambolin and Del Col16 introduced an improved procedure for the experimental characterization of optical efciency in evacuated tube solar collectors. The new method does not require a minimum number of data points for each data subset and thus it is less demanding in terms of required number of tests. In this study, an evacuated heat pipe solar collector with a circular n and a dry condenser has been theoretically modeled by heat transfer formulas, and its efciency and heat gain diagrams are compared with the results of experimental tests. The test procedure was adapted from the ISO 9806-1 (Ref. 17) test procedure. Additionally, the variation of the working (cooling) uid ow rate and its effect on the efciency and useful heat gain has been discussed, and the experimental and theoretical results are also presented.
II. THERMAL ANALYSIS

The heat pipe is a device with very high thermal conductance. The main components of the heat pipe are the evaporator, the condenser, and the contained working uid. When the evaporator is heated, the working uid is evaporated as it absorbs an amount of heat equivalent to its latent heat of vaporization. In the condenser section, the working uid vapor is condensed by a cooling uid. The method of condensate return is dependent on the heat pipe structure. Condensate return techniques include capillary force and gravity, among others. This cycle continues as the evaporator is heated.18,19 A solar heat pipe collector consists of a row of heat pipes that are connected to a manifold on the top that transfers the heat produced in the pipes to the working uid. A schematic of a wickless heat pipe that uses gravity for condensate return and an evacuated heat pipe collector schematic are shown in Figs. 1 and 2, respectively. In this study, an evacuated tube solar collector with a heat pipe has been modeled. The condenser part of the collector in the manifold was of the dry type. There are many advantages to the use of heat pipes for solar thermal applications. They have no moving parts, and if the condenser is of the dry type, maintenance difculties are reduced because a damaged heat pipe can be changed while the working uid is circulating. Moreover, leakage problems are reduced because of the indirect contact between the heat pipe and the condenser.9 Water was chosen as the working (cooling) uid because the local ambient temperature did not drop below its freezing point during the test. For simplicity, the following assumptions were made in the theoretical model:

The collector absorber area is always at a uniform temperature. The temperature gradient across the absorber thickness and over its perimeter is neglected. Because the evaporator section is subjected to a constant heat ux and the phase change occurs at a constant temperature, the temperature gradient along the longitudinal direction is negligible. The thermal contact resistance between the absorber area and the evaporator tube and between the condenser section and the condenser manifold is neglected. The connection of the evaporator and the condenser of the heat pipe is assumed to be adiabatic.

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-3

Evacuated tube solar heat pipe collector

J. Renewable Sustainable Energy 4, 023101 (2012)

FIG. 1. Heat pipe schematic.

The thermal resistance model that has been used is shown in Fig. 3. In the gure, I represents the solar radiation that reaches the collector surface, and I (sa) represents the radiation that reaches the absorber. A small part of the gained heat is wasted by radiation, which is shown by Qloss.rad. The useful heat gain, Qu, is calculated by subtracting the heat pipe collector heat gain, Qhp, from the manifold heat loss from the top of the collector, Qloss,ma. Rloss,rad is the radiation thermal resistance, which can be calculated and represented as follows: Rloss;rad Tp Ta : 4 T 4 A erTp r a (1)

The evaporator thermal resistance is represented by Rhp and is a combination of three resistances. These resistances are the circular n resistance, the copper pipe resistance, and the boiling lm condensation resistance inside the evaporator pipe. Thus, Rhp may be written as follows20: Rhp where  1 gql ql qv kl3 hfg 4 0:555 : ll Tp Tk Devap lnDo;fin =Di;fin lnDo;evap =Di;evap 1 ; 2pkevap Levap hhp Aevap 2pkfin Levap (2)

hhp

(3)

Rcond,w is considered to be the thermal resistance of the condenser section, which is the sum of the condensing lm resistance in the condenser, the condenser copper pipe section, and the dry manifold condenser resistance. The thermal contact resistance in the dry condenser is assumed to be negligible. Rcond,w may be written as:20 Rcond;w 1 lnDo;cond =Di;cond lnDo;ma =Di;ma ; hcond Acond 2pkcond Lcond 2pkma Lma (4)

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-4

F. Jafarkazemi and H. Abdi

J. Renewable Sustainable Energy 4, 023101 (2012)

FIG. 2. Evacuated heat pipe collector schematic.

where  1 gql ql qv kl3 hfg 4 : hhp 0:555 ll Tp Tk Dcond

(5)

The manifold resistance is also calculated by the common heat transfer formulas, as 1/UmaAma,loss. The heat transfer balance is written using the thermal resistance model shown in Fig. 3, as follows: _ loss;rad q _ hp q _ loss;rad q _u q _ loss;ma : _ in q q (6)

The expressions for the temperatures, resistances, and radiation are used in Eq. (6), and it yields the following:

FIG. 3. Thermal resistance model for an evacuated heat pipe collector.

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-5

Evacuated tube solar heat pipe collector

J. Renewable Sustainable Energy 4, 023101 (2012)

IsaAr

Tf Ta Tp Ta _u q : Rrad Rloss;ma

(7)

To simplify the derivation process, Rcond;w =Rrad is replaced by Rcr and Rhp =Rrad is replaced by Rhr. From the thermal resistance model, the following expression may be written: _ hp q Tp Tf ; Rhp Rcond;w Tf Ta : Rloss;ma (8)

_ hp q _u q _ loss;ma q _u q

(9)

Using the energy balance in the thermal resistance model and Eqs. (8) and (9) to simplify the useful heat gain equation, the following may be written,   Tf Ta IsaAr 1 1 _u 1 Rhr Rcr : q 1 Rhr Rcr 1 Rhr Rcr Rrad Rloss;ma Equation (10) may be written as _ u F0 Ar Isa UL Tf Ta ; q where F0 and UL 1 1 : Rrad Ar Rloss;ma Ar F0 (13) 1 ; 1 Rhr Rcr (12) (11) (10)

The collector heat removal factor can be calculated by the following equation:21    _ p mC UL Ar F0 FR 1 exp : _ p Ar UL mC (14)

FR is similar to heat exchanger effectiveness and is dened as the ratio of the actual heat transfer to the maximum possible heat transfer. The maximum possible heat transfer occurs when the collector is at the working uid inlet temperature.21 The actual collector useful heat gain may be calculated from the following: _ u Ar FR Isa UL Tf ;i Ta : q (15)

By incorporating the useful heat gain value, the heat gain of the working uid in the manifold _ u mC _ p Tf To , where To represents the outlet temperature of the can be expressed as q working uid and will be determined. The instantaneous efciency of a collector, which is the ratio of the useful energy to the solar radiation, can be expressed as follows:21 _ u =Ar I FR sa FR UL Tf ;i Ta =I: gq (16)

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-6

F. Jafarkazemi and H. Abdi

J. Renewable Sustainable Energy 4, 023101 (2012)

III. EXPERIMENTAL TEST AND PROCEDURE

Fig. 4 shows a schematic of the experimental conguration used for the efciency and performance evaluation of an evacuated heat pipe collector. The test facility and weather station are located on the roof of solar energy laboratory building of the Islamic Azad University South Tehran Branch. The collector tilt angle was set to 45 , facing south. The latitude and longitude of the test center are 35.6 N and 51.4 E, respectively. A picture from the test facility is shown in Fig. 5. The test plan for testing the collectors was adopted from ISO 9806-1 because it is known as an accepted standard in Iran. The specications of the system components are described below. The reservoir tank volume was 150 l, and the tank was made of galvanized steel. Calibrated Pt100 temperature sensors were used to measure the inlet and outlet uid temperatures of the collector and the reservoir tank. In order to control the tank uid temperature, two 2 kW electric heaters and one 1 kW heater were used. A calibrated ow meter with a range of 20-200 l/h was used to measure the inlet working uid ow rate. The heaters were controlled by a solid state relay (SSR) controller. A proportional integral derivative (PID) temperature controller was used for this purpose. The pyranometer, ambient temperature probe, and wind velocity sensor are all calibrated against reference instruments and supplied by Soldata Instruments. The weather data were logged at intervals of 10 min during the tests. The general specication of the tested collector, which is a heat pipe solar collector with 19 heat pipes, is presented in Table I. The test procedure which is used to test the performance and efciency, according to ISO 9806-1, is as follows. First, the temperature of the reservoir tank is kept constant with the heaters and controller. The water tank temperature is set to different values during each test period. The minimum temperature is set to the ambient temperature, and the other temperatures are set higher for the subsequent data points. Using the ow control valve, the ow is set to a constant rate, and after 10 min, when the outlet temperature is constant, the collector outlet temperature

FIG. 4. Schematic diagram of the test set-up.

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-7

Evacuated tube solar heat pipe collector

J. Renewable Sustainable Energy 4, 023101 (2012)

FIG. 5. Test facility.

is recorded. This procedure is repeated for ve other temperatures in each test period with steps of approximately 8  C. The test procedure is also repeated for two other ow rates. The time periods are chosen such that the data points represent times symmetrical to the solar noon. In this study, the test is performed for two collectors, one with 19 heat pipes and the other with 4 heat pipes. The experimental efciency and the useful heat gain of each solar collector are compared to the theoretical calculated values to evaluate the accuracy of the model. The effect of the three ow rates on the efciency and heat gain is discussed after the test procedure was completed.
IV. RESULTS AND DISCUSSION

The test for evaluation of the heat pipe performance was performed in August 2011. The climate conditions on August 8 and August 15, 2011 when the tests were performed are shown in Fig. 6. The tests were performed for 19 heat pipes and 4 heat pipes on days 1 and 2, respectively. The ow rates were set to 0.056, 0.042, and 0.028 kg/s for the 19 heat pipe collector and 0.014, 0.010, and 0.007 kg/s for the 4 heat pipe collector for the tests. These are based on requirement of ISO 9806-1, which recommends a ow rate of 0.02 kg/s/m2 for collector testing. Other ow rates were chosen to compare the ow rate effect on heat gain and efciency.
TABLE I. Specications of an evacuated collector. Parameter (unit) Aperture area (m ) Absorber area (m2) Emittance Tube spacing (m) Tube length (m) Condenser O.D. (m) Condenser length (m) Evaporator O.D. (m) Absorber absorptance Glass cover transmittance
2

Value 2.50 1.78 0.07 0.078 1.7 0.024 0.065 0.008 0.93 0.90

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-8

F. Jafarkazemi and H. Abdi

J. Renewable Sustainable Energy 4, 023101 (2012)

FIG. 6. Climate conditions for the two test days (a) August 8 and (b) August 15.

The theoretical and experimental efciencies, useful heat gains and inlet and outlet temperatures for the collector with 19 heat pipes and a ow rate of 0.042 kg/s of working uid is shown in Table II as an example. For each working uid ow rate, this table should be made available before processing the data. The collector ow factor, F00 , which is the ratio of FR to F0 , is a function of a single vari_ p =Ar UL F0 . This factor is shown in Fig. 7 able, the dimensionless collector capacitance rate mC for a working uid ow rate of 0.028 kg/s and a collector with 19 heat pipes. The theoretical (calculated) collector outlet temperatures and experimental (measured) collector outlet temperatures are shown in Fig. 8. The data points shown correspond to the collectors with both 4 heat pipes and19 heat pipes and all six ow rates. The predicted values are in good agreement with the experimental results to within an error of less than 5%, which means that the theoretical model is acceptable. Figs. 9 and 10 show the rise in the working uid temperature for different ow rates. These gures indicate that the experimental outlet and inlet temperature difference increases as the working uid ow rate decreases. Additionally, while the ratio of the temperature difference to the incident radiation increases, the experimental outlet and inlet temperature difference also decreases. This result indicates that in order to reach the maximum outlet temperature, the optimum condition is to have a reduced working uid ow rate and a smaller difference between the inlet and ambient temperatures. The slopes of the diagrams are nearly the same, which means that the results do not depend on the collector area or the number of heat pipes. The theoretical collector heat gain and the experimental results during the testing day for different ow rates are shown in Figs. 11 and 12. The theoretical and experimental heat gains are shown by lines and rectangular diagrams, respectively. The model prediction is close in value to the experimental results at most data points. As expected, when the difference between the inlet and ambient temperatures increases, the useful heat gain decreases, and vice versa.

TABLE II. Data table for the collector with 19 heat pipes and a working uid ow rate of 0.042 kg/s. Time Temp ( C) Experimental Toutlet 77.4 71.4 63.4 56.7 48.5 44.8 Theoretical Toutlet 78.69 71.93 64.01 56.93 49.33 45.19 Efficiency (%) Useful heat gain (W) Radiation I (W/m2) 757.9 806.4 826.6 822.6 830.7 790.2

Hour 11:25 12:00 12:25 13:00 13:30 14:10

Tinlet 75.1 67.9 59.7 52.5 44.7 40.7

Tamb 34.4 36 36.5 37.8 37.7 39.4

Theoretical 46.39 48.88 50.98 52.76 54.54 55.63

Experimental 29.67 42.43 43.76 49.91 44.72 50.72

Theoretical 625.87 701.57 750.13 772.47 806.50 782.45

Experimental 400.22 609.04 643.84 730.85 661.24 713.45

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-9

Evacuated tube solar heat pipe collector

J. Renewable Sustainable Energy 4, 023101 (2012)

FIG. 7. Collector ow factor.

FIG. 8. Theoretical model and comparison with experimental results for outlet temperature.

FIG. 9. Variation in the working uid temperature in a collector with 19 heat pipes for different ow rates.

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-10

F. Jafarkazemi and H. Abdi

J. Renewable Sustainable Energy 4, 023101 (2012)

FIG. 10. Variation in the working uid temperature in a collector with 4 heat pipes for different ow rates.

FIG. 11. Comparison of theoretical and experimental heat gain for a collector with 19 heat pipes.

FIG. 12. Comparison of theoretical and experimental heat gain for a collector with 4 heat pipes.

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-11

Evacuated tube solar heat pipe collector

J. Renewable Sustainable Energy 4, 023101 (2012)

FIG. 13. Predicted efciency from the theoretical model vs. efciency determined from the experimental results for the collector with 19 heat pipes.

This result indicates that more heat can be gained from the collector when the inlet and ambient temperature difference is kept near zero. Figs. 13 and 14 show a comparison between the efciency predicted using the theoretical model vs. that obtained using the experimental results for the two collectors at different ow rates. The experimental results are close in value to the predicted results of the model for both collectors. As the ow rate of the working uid and the number of heat pipes increase (Fig. 13), efciency decreases. On the other hand, as shown in Fig. 14, for a collector with smaller area and reduced working ow rate, the rate of efciency decrease (slope) is higher. This result indicates that it is possible to reach higher efciencies by decreasing the collector aperture area, but the substantial rate at which the efciency decreases should be considered. The instantaneous efciency decreases as the ratio of the temperature difference to the incident radiation increases in both diagrams. The values of FRUL and FR(sa) are estimated for both collectors. FRUL is the slope of the straight regression line, and FR(sa) is the value of the point of intersection with the y-axis in the region of maximum efciency. By linear curve tting of the data points for the collector with 19 heat pipes, the experimental values of FRUL for ow rates of 0.056, 0.042, and 0.028 kg/s are equal to 3.77, 3.36, and 3.45, respectively, while the theoretical model yields 1.87, which was approximately constant for all ow rates. The FR(sa) values that

FIG. 14. Predicted efciency from the theoretical model vs. efciency determined from the experimental results for the collector with 19 heat pipes.

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-12

F. Jafarkazemi and H. Abdi

J. Renewable Sustainable Energy 4, 023101 (2012)

are determined from the experimental results are equal to 0.55, 0.52, and 0.51 for ow rates of 0.056, 0.042, and 0.028 kg/s, respectively, while the theoretical model yields 0.56, which was approximately constant for all ow rates. For the collector with 4 heat pipes, the experimental value of FRUL for ow rates of 0.014, 0.010, and 0.007 kg/s are 8.86, 8.85, and 10.03, respectively, while the theoretical model yields 8.5,which was approximately constant for all ow rates. The experimental FR(sa) values are 0.73, 0.72, and 0.76 for ow rates of 0.014, 0.010, and 0.007 kg/s, respectively, while the theoretical model yields 0.79, which was approximately constant for all ow rates.
V. CONCLUSIONS

In this study, a comparison between the theoretical and experimental results for two collectors with different numbers of heat pipes and different aperture areas were made. The results led to the following ndings. The theoretical model is in good agreement with the experimental results and is capable of predicting the efciency, useful heat gain, and working uid outlet temperature of an evacuated tube heat pipe collector with good accuracy. The effect of the ow rate on the efciency and heat gain were also discussed theoretically and experimentally. It is found that decreasing the ow rate leads to a higher outlet temperature for an evacuated tube heat pipe collector. It has been shown that the efciency of the collector decreases as the ratio of the inlet temperature to the incident radiation increases. It is recommended that the inlet water temperature is kept as near as possible to the ambient temperature to gain more heat and higher efciency.
ACKNOWLEDGMENTS

The authors would like to acknowledge the nancial support of Islamic Azad University, South Tehran Branch (under Contract No. B/16/561).
NOMENCLATURE

Ar Cp D F0 F00 FR h I k _ m _ q R t T UL  g l q sa

collector area (m2) specic heat capacity (J/kg K) diameter (m) collector efciency factor collector ow factor collector heat removal factor heat transfer coefcient (W/m2 K) incident solar radiation (W/m2) thermal conductivity (W/m K) mass ow rate (kg/s) heat transfer rate (W) resistance (W/K) wall thickness (m) temperature (K) overall heat transfer coefcient of collector (W/m2 K) emittance coefcient efciency dynamic viscosity (N s/m2) density (kg/m3) transmittance absorbance product

SUBSCRIPTS

a cond

ambient condenser

Downloaded 07 Nov 2012 to 80.66.183.34. Redistribution subject to AIP license or copyright; see http://jrse.aip.org/about/rights_and_permissions

023101-13

Evacuated tube solar heat pipe collector

J. Renewable Sustainable Energy 4, 023101 (2012)

evap exp f g hp i l ma o p rad u w


1

evaporator experimental or measured working uid gas heat pipe inlet liquid manifold outlet plate radiation useful wall

H. Kazemi Karegar, A. Zahedi, V. Ohis, G. Taleghani, and M. Khalaji, Wind and Solar Energy Developments in Iran, in Australasian Universities Power Engineering Conference (AUPEC), Melbourne, Australia, 29 Sep2 Oct 2002. 2 F. Mahdjuri, Energy Convers. 19, 85 (1979). 3 U. Ortabasi and F. P. Fehlner, Sol. Energy 24, 477 (1980). 4 H. P. Garg, S. Chakravertty, A. R. Shukla, R. C. Agnihotri, and M. Indrajit, Energy Convers. Manage. 23, 157 (1983). 5 C. I. Ezekwe, Sol. Wind Technol. 7, 349 (1990). 6 E. Zambolin and D. Del Col, Sol. Energy 84, 1382 (2010). 7 S. Fischer, W. Heidemann, H. Mu ller-Steinhagen, B. Perers, P. Bergquist, and B. Hellstro m, Sol. Energy 76, 117 (2004). 8 EN 12975-2, Thermal Solar Systems and ComponentsSolar CollectorsPart 2: Test Methods (British Standards Institution, London, 2001). 9 K. C. Ng, C. Yap, and T. H. Khor, J. Process. Mech. Eng. 214, 23 (2000). 10 E. Azad, Exp. Therm. Fluid Sci. 32, 1666 (2008). 11 L. M. Ayompe, A. Duffy, M. Mc Keever, M. Conlon, and S. J. McCormack, Energy 36, 3370 (2011). 12 M. Hayek, J. Assaf, and W. Lteif, Energy Procedia 6, 618 (2011). 13 F. Jafarkazemi, H. Abdi, A. Asadzadeh Zargar, and A. Hassani, Development of a solar collector/solar water heating system test center in Iran, Solar World Congress, Kassel, Germany, 28 Aug2 Sep 2011. 14 A. W. Badar, R. Buchholz, and F. Ziegler, Sol. Energy 85, 1447 (2011). 15 R. Tang, Y. Yang, and W. Gao, Sol. Energy 85, 1381 (2011). 16 E. Zambolin and D. Del Col, Renewable Energy 43, 37 (2011). 17 ISO 9806-1, Test Method for Solar CollectorsPart 1: Thermal Performance of Glazed Liquid Heating Collectors Including Pressure Drop (International Organization for Standardization, Geneve, 1994). 18 D. A. Reay and P. A. Kew, Heat Pipes Theory, Design and Applications, 5th ed. (Butterworth-Heinemann, Oxford, UK, 2006). 19 A. Bejan and A. D. Kraus, Heat Transfer Handbook (Wiley, New York, 2003). 20 F. P. Incropera and D. P. DeWitt, Introduction to Heat Transfer, 5th ed. (Wiley, New York, 2001). 21 J. A. Dufe and W. A. Beckman, Solar Engineering of Thermal Processes, 3rd ed. (Wiley, New York, 2006).