SECTION 09210 GYPSUM PLASTER & INTERNAL AND EXTERNAL RENDER SYSTEM

REVISION HISTORY

B A 0 Rev

05.06.03 23.02.03 08.02.03 Date

Clause 2.5.2 included General Revisions Standard Specification Gypsum Plaster & Internal and External Render System Description

David Duggan David Duggan Phill Bridger Prepared by

Paul Roberts Paul Roberts Paul Roberts Checked by

Roger Nickells Richard Smith Richard Smith Authorised by

WSA/D1204 Rev B/2003

09210/1

Gypsum Plaster & Internal and External Render System

1
1.1

GENERAL
SECTION INCLUDES The Contractor shall become familiar with other sections of the Specifications affecting work of this trade. Furnish all labour, material, plant, equipment and appliances and perform all necessary operations required to execute the work of this section. Gypsum plaster finish coat to plasterboard. Internal and External sand cement render. Priming of base material to be included. RELATED SECTIONS This schedule is intended to be used as a helpful indication of the related sections within the Project Specifications. It is not necessarily comprehensive or complete and it is the Contractor's responsibility to ascertain all applicable sections required to understand the full Scope of Works intended. Section 03300 Section 03411 Section 04300 Section 07900 Section 09200 Cast in Place Concrete PreCast Concrete Unit Masonry System Joint Sealers Gypsum Board Systems

1.1.1 1.1.2 1.1.3 1.1.4 1.1.5 1.2 1.2.1

1.3 1.3.1

REFERENCES The minimum standards for products specified in this section shall be relevant BSI standards including but not limited to the following. Except as otherwise specified herein, perform work in accordance with specification codes and standards cited therein and to latest applicable addenda and supplements. BS 443 BS 882 BS 890 BS 1191 BS 1191 BS 1198 BS 1198 BS 1200 BS 1202 BS 1369 BS 1494 Part 2 BS 1521 BS 3148 BS 3416 & BS 6949 BS 6100-6.1 & 6.6.2 BS 4721 BS 4887 BS 5262 BS 5492 BS 6452 Galvanized Wire Aggregates Limes Part 1 - Lightweight Plasters Part 2 - Premixed Plasters Sands - Internal Plastering Sands - External Rendering Sands for Mortars Nails Metal Lath Fixings Waterproof Papers Water for Plastering Black Bitumen Solutions Glossary of Terms Internal Plastering Ready-mixed Lime/Sand for Mortar Mortar Plasticizers Code of Practice for Render Code of Practice for Internal Plastering Beads for Plastering 09210/2 Gypsum Plaster & Internal and External Render System

WSA/D1204 Rev B/2003

BS EN ISO 1461 BS 8000 BS 8290 1.4 1.4.1 1.4.2 SUBMITTALS

Hot Dip Galvanizing Part 10 Code of Practice for Plastering and Rendering Suspended Ceilings Metal Fixing Systems

Submit under provisions of Section 01300. Submit samples, specifications, description of system and installation method in accordance with the Contract Documents. Submission shall indicate all dimensions, details of construction, details of installation, relation and connections with adjoining work, reinforcement, welds, fastenings, anchorages and shop and site finishes. Before submission of shop drawings submit to the Engineer a complete listing of testing agencies, manufacturers, fabricators and subcontractors for all types of plasterwork and render. Submit copies of reports of tests performed on the proposed products. installations completed, where proposed products were used. Submit a list of

1.4.3

1.4.4 1.4.5 1.4.6 1.4.7 1.5 1.5.1 1.6 1.6.1 1.7 1.7.1 1.7.2 1.7.3 1.7.4 1.7.5 1.7.6 1.8 1.8.1

Submit, in accordance with the Contract Documents, to the Engineer copies of the information from the manufacturer confirming compliance with the specification. Certificate (in the form of standard data sheet or letter) that materials and products to be used comply with these specifications. Submit samples of the specified plaster and render materials to show the surface texture and the maximum range or variation in colour and shade, beads, movement joints etc. QUALITY ASSURANCE Perform Work in accordance with relevant British Standard. QUALIFICATIONS Applicator: Company specializing in performing the work of this section with minimum 5 (five) years documented and proven experience approved by manufacturer. MOCKUP Provide mockup of Venetian plaster under provisions of Section 01400. Provide mock up of colour through render from approved supplier. Provide mockup of skim plaster to plasterboard. Provide mockup of external sand cement render Construct mockup on both concrete and blockwall within area to be agreed with Engineer. Mockup may remain as part of the Work as agreed with Engineer. ENVIRONMENTAL REQUIREMENTS Do not apply plaster when substrate or ambient air temperature is less than 10 degrees C nor more than 27 degrees C or as agreed with engineer.

WSA/D1204 Rev B/2003

09210/3

Gypsum Plaster & Internal and External Render System

1.8.2

Provide water curing to external render as necessary.

2
2.1

PRODUCTS
MATERIALS Plaster: Gypsum Plaster Class B - natural gypsum/calcium sulphate from an approved source.

2.1.1

2.1.2 2.1.3 2.1.4 2.2 2.2.1 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 2.4 2.4.1 2.5 2.5.1 2.5.2 2.6 2.6.1

Water: Clean, fresh, potable and free of mineral or organic matter which can affect plaster. Bonding Agent: surfaces. type recommended for bonding plaster to concrete and concrete block

Undercoat - 10mm gypsum plaster in single coat. FINISHING PLASTER 3mm lightweight gypsum finishing plaster to BS 1191 Class B type B2 board finish plasters. ACCESSORIES Beads/stops for internal use to be galvanised steel to BS 6452. Beads/stops for external use to be galvanised steel to BS 2989 designation Z2G450N and passivated. Dissimilar solid backgrounds for plaster. 200mm wide galvanised mesh strip for backgrounds in the same plane and galvanised corner mesh at internal angles fixed not more than 600mm centres along both edges. Fasteners: Nails, staples, or other approved metal supports, of type and size to suit application, galvanized, to rigidly secure lath and associated metal accessories in place. PLASTER MIX Mix and proportion plaster and render in accordance with British Standards and manufacturer's instructions. EXTERNAL RENDER 15mm minimum 2-coat sand cement render base to primed block work. Sand to lime to cement mix of 1.1.5 to 1.1.6. INTERNAL RENDER 12mm minimum 2 coat sand cement render to primed blockwork.

WSA/D1204 Rev B/2003

09210/4

Gypsum Plaster & Internal and External Render System

3
3.1

EXECUTION
EXAMINATION Verify site conditions under provisions of Section 01100. Verify that surfaces and site conditions are ready to receive work. Masonry: Verify joints are cut flush and surface is ready to receive work of this section. Verify no bituminous or water repellent coatings exist on masonry surface. Concrete: Verify surfaces are flat, honeycomb is filled flush, and surface is ready to receive work of this section. Verify no bituminous, water repellent, or form release agents exist on concrete surface that are detrimental to plaster or plaster bond. Acceptance of Backgrounds: Before starting preparation and applying coatings ensure that backgrounds are secure, adequately true and level to achieve specified tolerances, free from contamination and loose areas, reasonably dry and in a suitable condition to receive specified coatings. Ensure that all cutting, chasing, fixing of concealed conduits, service outlets, fixing pads and the like and making good of the background, are completed. Remove efflorescence, laitance, dirt and other loose material by thoroughly dry brushing. Remove all traces of paint, grease, dirt and other materials incompatible with coating by scrubbing with water containing detergent and washing off with plenty of clean water. Allow to dry before applying coatings unless specified otherwise. Scrub in situ concrete surfaces with water containing detergent to ensure complete removal of mould oil, surface retarders and other materials incompatible with coating. Rinse with clean water and allow to dry unless specified otherwise. Grounds and Blocking: installed. Verify items within walls for other sections of work have been

3.1.1 3.1.2 3.1.3 3.1.4

3.1.5

3.1.6 3.1.7

3.1.8

3.1.9

3.1.10 Mechanical and Electrical: Verify services within walls have been tested and approved. 3.2 3.2.1 3.2.2 3.2.3 3.2.4 3.3 3.3.1 3.3.2 3.3.3 3.3.4 PREPARATION Dampen masonry surfaces to reduce excessive suction. Clean concrete surfaces of foreign matter. Thoroughly dampen surfaces before using acid solutions, solvent, or detergents to perform cleaning. Wash surface with clean water. Roughen smooth concrete surfaces and smooth faced masonry. Apply bonding agent in accordance with manufacturer's instructions. INSTALLATION - ACCESSORIES Continuously reinforce internal angles with corner mesh, return metal lath 75mm from corner to form the angle reinforcement; fasten at perimeter edges only. Place corner bead at external wall corners; fasten at outer edges of lath only. Place strip mesh diagonally at corners of lathed openings. Secure rigidly in place. Place metal lath over backing materials. Secure rigidly in place at centres of not more than

WSA/D1204 Rev B/2003

09210/5

Gypsum Plaster & Internal and External Render System

600mm along both edges. 3.3.5 3.3.6 3.3.7 3.4 3.4.1 3.4.2 3.5 3.5.1 3.5.2 Place casing beads at terminations of plaster finish. Butt and align ends. Secure rigidly in place. Install frames plumb and level in opening. Secure rigidly in place. Position to provide convenient access to concealed work requiring access. CONTROL AND EXPANSION JOINTS Locate expansion joints every 5m on external walls and in positions agreed with Engineer using double casing bead spaced 3mm apart to form joint filled with 2-part polysolphide. Coordinate joint placement with other related work. PLASTERING Apply gypsum plaster in accordance with relevant British standards and manufacturer's instructions. Apply each coating firmly to achieve good adhesion and in one continuous operation between angles and joints. All coatings to be not less than the thickness specified, firmly bonded, of even and consistent appearance, free from rippling, hollows and ridges. Finish surfaces to a true plane, to correct line and level, with all angles and corners to a right angle unless specified otherwise, and with walls and reveals plumb and square. Prevent excessively rapid or localised drying out. Dubbing Out: If necessary to correct inaccuracies, dub out in thicknesses of not more than 10mm in same mix as first coat. Allow each coat to set before the next is applied. Cross scratch surface of each dubbing out coat immediately after set. Dubbing out will not be permitted on smooth dense concrete surfaces except as recommended by the plaster manufacturer. Undercoats generally to be not less than 8mm thick with thicknesses greater than 16mm applied as two equal coats. Rule to an even surface and cross scratch each coat to provide a key for the next hand-applied coat. Apply finish coat to minimum 3mm thickness. Smooth Finish: Trowel or float to produce a tight, matt, smooth surface with no hollows, abrupt changes of level or trowel marks. Do not use water brush and avoid excessive trowelling and over polishing. Perform work in panels to nearest natural break or between accessories. TOLERANCES Maximum Variation from True Flatness: 3mm in 3 m. END OF SECTION

3.5.3 3.5.4 3.5.5

3.5.6

3.5.7 3.5.8

3.5.9 3.6 3.6.1

WSA/D1204 Rev B/2003

09210/6

Gypsum Plaster & Internal and External Render System