syngo X Workplace

Environmental Product Declaration

www.siemens.com/healthcare

Progress that is Impressive Ecological Advantages of the syngo X Workplace


The syngo X Workplace allows SW-based 3D reconstruction without the need for dedicated hardware, based on the already installed graphics adapter A standby mode can be used to save energy when the system is not in use Furthermore, the connected acquisition system can be used without the syngo X Workplace when no parallel processing and no 3D reconstruction are needed during the intervention All substances contained in the product and its packaging are documented Plastic parts are labeled for recycling Disassembly instructions for high-quality recycling are available Complete systems and their components can be taken back and refurbished Product take-back according to strict EU directives More than 90 % of the materials used can be returned to the flow of recyclable materials Environmental product declaration is available for download via internet

The syngo X Workplace Intelligent Postprocessing for X-ray Systems


The syngo X Workplace is a medical workstation for realtime viewing, image manipulation, 3D visualization, commu nication, and storage of medical images and data on exchange media. It is used for diagnostic image viewing and post processing during interventional procedures. The syngo X Workplace can be configured a stand-alone diagnostic review, post processing and reporting workstation. It can also be configured within a network to send and receive DICOM data. Furthermore, the syngo X Workplace can be combined with any system of the Artis zee family. In combination with an Artis zee or Artis zeego system, it provides image-guided solutions in the interventional room for: image-guided surgery using image fusion and navigation systems interventional cardiology interventional electrophysiology interventional oncology interventional radiology, and interventional neuroradiology

Environmental Management System


Our environmental, health and safety management system complies with ISO 14001 and aids us in putting our policy into practice. To find further information about our management system for environmental protection, health and safety, go to www.siemens.com/healthcare-ehs

Environmental Product Design


Material supply: From natural resources to delivery of semi-finished products Production/delivery: From production of components to operation startup by the customer Use/maintenance: Includes daily use by our customers as well as maintenance End of life: From disassembly at the customer through material and energy recycling Siemens Healthcare considers environmental aspects in all phases of the product life cycle, including material supply, production/delivery, use/maintenance and end of life. Our product design procedure fulfills the requirements of IEC60601-1-9:2007 Environmental product design for medical electrical equipment. This standard supports the effort to improve the environmental performance of our products.

Reduction of Critical Substances and Energy Consumption


Siemens has made strides to reduce materials in our syngo X Workplace system that are environmentally harmful and are not easily recyclable. One example is the removal of an addition ally required reconstruction board that has been replaced by SW-based reconstruction using the graphics adapter already installed inside the system, which reduces the use of toxic materials and energy consumption. Moreover, standby mode can be used to save energy when the system is not in use. The syngo X Workplace is mainly built of metals. This provides a high degree of recyclability. Although Siemens has already eliminated a great amount of nonrecyclable materials, we are continually making improvements to reduce the environmental impact of Siemens products even more.

Identification of Product Materials

Critical substances and selective parts 19.5 %

Ferrous alloys, steels 43.9 %

Other materials 8.0 %

Plastics 11.5 % Inorganic materials and ceramics 1.8 % Total weight: approx. 56 kg
4

Other metals and semi metals 0.1 %

Nonferrous metals and alloys 15.2 %

Cumulative Energy Demand


Energy consumption is the most im portant environmental characteristic of medical devices. This is why we use Cumulative Energy Demand to assess environmental performance. Cumulative Energy Demand is the total primary energy* that is necessary to produce, use and dispose of a device including all transportation. Our medical devices can be recycled almost completely for materials or energy. With appropriate handling at the end of a products service life, it is possible to return up to 1 MWh in the form of secondary raw materials or thermal energy to the economic cycle. 25 Primary Energy in MWh 17 15

3 1 Production and Transportation End of Life

5 Material Supply Usage (per 6 years)

Packaging
Our recording solutions are shipped in open packaging within Europe and to the USA. We use open packaging for more than 74 % of our shipments. The individual parts of a delivery need only be wrapped in dust-protective covers. In turn, they are loaded in a special trans port frame, which travels from the supp lier to the endcustomer and is then returned for reuse. We use closed packaging only for tropical countries or countries where the law so requires. The wooden crates or sealed packaging can then be used for material, or to some extent, thermal recycling. Values listed on the right represent average values from these two types of packaging. Total Weight Open packaging approx. 15 kg Closed packaging approx. 48 kg Paperboard 13 %

Ferrous alloys, steels 6% Plastics 2%

Wood 79 %

Product Take-Back
Most of the materials used to produce syngo X Workplace products are recyclable. 90 % of material (by weight) and 4 % of the energy value can be recycled. Our product disposal program ensures that we address the environmental aspects of our products even the end of the product life cycle. As part of this program, we refurbish systems and reuse components and replacement parts whenever possible through our Refurbished Systems business. We reuse components and subsystems for non-medical products. We also recycle for material or energy value. Disassembly instructions for disposal and recycling are available for our products.
* Primary energy is the energy contained in natural resources prior to undergoing any man-made conversions (e.g. oil, solar).

Operating Data Operating conditions Allowed ambient temperature + 10 C to + 35 C Sound pressure level < 30 dB (A) for standard model Power Consumption Standby Full load 250 W Max. 1 kW

With the option that is available for display of the syngo X Workplace in the examination room, Siemens achieves a significant reduction in energy consumption when the display is in stand-by mode. Up to 750 watts can be saved when stand-by mode is activated. Disposal / Substance Information End-of-life concept Recycling information List of hazardous substances Yes Yes Yes

Displays The standard configuration does include a display. The following displays can be used with the syngo X Workplace: Type* Flat-screen color display, high-end Flat-screen monochrome display for X-ray diagnostics Large display** Cockpit**
6

Format 19 19 56 30

Resolution (pixels) 1.3 megapixel 1.3 megapixel 8.3 megapixel 4.1 megapixel

DSC 1908-D DSB 1906 DSC 5608 DC MX 300 W

* Later models of the above displays may also be ordered; ** In combination with Artis zee

Further Ecologically Relevant Information Elements of instruction are: recommendations for saving energy recommendations for efficient cleaning recommendations for appropriate use of consumables Yes Yes Yes

Hazardous substances and preparations Products do not contain lead max. 0.1 %, cadmium max. 0.01 %, mercury max. 0.1 %, hexavalent chromium max. 0.1 %, polybrominated biphenyls (PBB) max. 0.1 % and polybrominated diphenyl ethers (PBDE) max. 0.1 % Batteries Button cells used in the product do not contain more than 2 % by weight of mercury. Other batteries or accumulators do not contain more than 0.0005 % of mercury or 0.002 % of cadmium. Product packaging Packaging and packaging components do not contain lead, mercury, cadmium and hexavalent chromium max. 0.01 % by weight of these together. More information available in the syngo X Workplace Operating Manual

On account of certain regional limitations of sales rights and service availability, we cannot guarantee that all products included in this brochure are available through the Siemens sales organization worldwide. Availability and packaging may vary by country and are subject to change without prior notice. Some/All of the features and products described herein may not be available in the United States or other countries. The information in this document contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases. Siemens reserves the right to modify the design, packaging, specifications and options described herein without prior notice. Please contact your local Siemens sales representative for the most current information. In the interest of complying with legal requirements concerning the environmental com patibility of our products (protection of natural resources and waste conservation), we recycle certain components. Using the same extensive quality assurance measures as for factory-new components, we guarantee the quality of these recycled com ponents. Note: Any technical data contained in this document may vary within defined tolerances. Original images always lose a certain amount of detail when reproduced.

Global Business Unit Address Siemens AG Medical Solutions Angiography & Interventional X-Ray Systems Siemensstrasse 1 DE-91301 Forchheim Germany Telephone +49 9191 18-0 www.siemens.com/healthcare

Global Siemens Headquarters Siemens AG Wittelsbacherplatz 2 80333 Muenchen Germany

Global Siemens Healthcare Headquarters Siemens AG Healthcare Sector Henkestrasse 127 91052 Erlangen Germany Telephone +49 9131 84-0 www.siemens.com/healthcare

Legal Manufacturer Siemens AG Wittelsbacherplatz 2 DE-80333 Muenchen Germany

www.siemens.com/healthcare
Order No. A91AX-21101-21T1-7600 | Printed in Germany | H IM AX MK CC pdf version only | 05.2012 Siemens AG

Das könnte Ihnen auch gefallen