Sie sind auf Seite 1von 66

NCRRealPOS80c

Release1.2

SitePreparationGuide

B00500001360
IssueC

TheproductdescribedinthisbookisalicensedproductofNCRCorporation.
NCRisaregisteredtrademarkofNCRCorporation.
ItisthepolicyofNCRCorporation(NCR)toimproveproductsasnewtechnology,components,software,
andfirmwarebecomeavailable.NCR,therefore,reservestherighttochangespecificationswithoutprior
notice.
Allfeatures,functions,andoperationsdescribedhereinmaynotbemarketedbyNCRinallpartsofthe
world.Insomeinstances,photographsareofequipmentprototypes.Therefore,beforeusingthisdocument,
consultwithyourNCRrepresentativeorNCRofficeforinformationthatisapplicableandcurrent.
Tomaintainthequalityofourpublications,weneedyourcommentsontheaccuracy,clarity,organization,
andvalueofthisbook.
Addresscorrespondenceto:
Manger,InformationProducts
NCRCorporation
2651SatelliteBlvd.
Duluth,GA30096
Copyright2002
ByNCRCorporation
Dayton,OhioU.S.A.
AllRightsReserved

Preface
Thisisacontractualdocument.Itcontainsimportantwarningsand
confersimportantlegalrightsandobligations.Youareadvisedtoread
itcarefully.
Itistheresponsibilityofthecustomertoensurethatallinstallation
preparationsarecompleteandincompliancewithNCRspecifications
andrequirementsandallapplicablenational,state,orlocalcodes,
regulations,andlaws.

Safety Requirements
TheNCR7456TerminalmustbeconnectedtoanACoutletthatisnear
theterminalandiseasilyaccessiblebytheoperator.
Warning: Thisunitcontainshazardousvoltagesandshouldonlybe
servicedbyqualifiedservicepersonnel.
Theon/offswitchisalogicswitchonly.TheAClinevoltageprimaries
areliveatalltimeswhenthepowercordisconnected.Therefore,
disconnecttheACpowercordbeforeopeningtheunittoinstall
featuresorservicethisterminal.

Peripheral Usage
The7456shouldbeusedonlywithperipheraldevicesthatare
recommendedbyNCRCorporationandarecertifiedbythe
appropriatesafetyagencyforthecountryofinstallation(UL,CSA,
TUV,VDE).

ii

About this Book


ThisbookprovidessitepreparationinformationforNCR7456
Terminalcomponents.PeripheralcomponentandACwiringsite
preparationinformationisNOTprovidedinthisbook.Theassociated
referencedocumentsarelistedintheRelatedSitePreparationData
section.
Thisbookcontainstheinformationnecessaryforthepreparationofa
siteconformingtotheNCRspecifications.Itisveryimportantthatthe
sitecomplieswiththerequirementsspecifiedinthedocumentbecause,
oncetheequipmenthasbeeninstalled,deficienciesinsitepreparation
ortheproblemscausedbythesedeficienciesaremuchmoredifficultto
detectandcorrect.Further,failuretocomplywiththeserequirements
ortotakeproperstepstoprotectequipmentagainstrisksidentifiedin
thisdocumentmaycauseseriousdamagetotheequipmentandtothe
customersbusiness.
Inadditiontotheneedtocomplywiththerequirementsspecified,
electricalwiring,andmechanicalsystemsmustalsocomplywithall
relevantcodes,laws,andregulations.
Itisimportantthatthesitebepreparedbyacustomerorhisagentwho
isfullyconversantwiththespecialrequirementsofelectronic
equipment.Theresponsibilityofensuringthatthesiteispreparedin
compliancewiththisdocumentremainswiththecustomer.
Forinformationandguidancepurposesonly,alistisprovided,in
generalterms,ofthosemattersforwhichthecustomerisresponsible.
Thislistisnotintendedtobecomprehensive,andinnowaymodifies,
alters,orlimitstheresponsibilityofthecustomerforallaspectsof
adequatesitepreparation.

iii

NCRstaffwillbeavailabletoanswerquestionsrelatingtothecontents
ofthisdocumentexceptwhere:

acustomerhasbeennotifiedthatafullorpartialconsultancy
serviceisavailableand/orthatNCRwillbewillingtoundertakea
preliminaryorfinalsitesurveyand

thecustomershallhaveenteredintoaformalcontractwithNCR
forprovisionofthesame.

Nocomment,suggestion,oradviceofferedornotofferedabout
preparationofthesitenoranyinspectionofthesitewhetherbeforeor
afterpreparationistobetakenasapprovalofthelocationofthesite
andequipmentoritspreparationandNCRwillnotbeliableinrespect
ofanycomment,suggestion,oradvicegivenbyitsstafforinrespectto
anyfailuretogiveadvice.
Finally,onlythecustomercanknowthefullextentofdamagewhich
maybecausedtohisbusinessbyreasonoffailureoftheequipment
whichistobeinstalled.Forthisreasonitisthecustomers
responsibilitytoascertaintheextentofanypossibledamagetohis
existingorplannedbusiness,andtoeffectfullinsuranceinrespectofit.

iv

Table of Contents
Introduction

RelatedSitePreparationDocuments

ACPowerandCommunicationsWiring.............................................. 2
Peripherals ................................................................................................ 2
WheretoObtainInformationProducts ................................................ 3
CustomerResponsibilities

ACStoreWiringRequirements

LANCommunications

SystemConfigurationDiagrams

HandlingSystemComponents

ServiceClearanceRequirements

OperatingClearanceRequirements

ComponentDimensions

IntegratedConfigurations ...................................................................... 9
5942LCDOperatorDisplay............................................................. 9
5953DynaKey .................................................................................. 11
9InchCRT........................................................................................ 12

vi

BaseUnit ................................................................................................. 12
CashDrawers ......................................................................................... 13
NCR2182 .......................................................................................... 13
NCR2189 .......................................................................................... 13
NCR2183 .......................................................................................... 14
Displays ................................................................................................... 15
7452K3099InchMonochromeCRT(4970418913).................... 15
7452K4049InchMonochromeCRT(4970418913).................... 16
7452K41915InchMonochromeCRT(4970414126).................. 17
59825InchMonochromeLCDOperatorDisplay....................... 18
5972/59732x20RemoteCustomerDisplayonaShort
Mount(VFD) .................................................................................... 19
597212002x20RemoteCustomerDisplayona16Inch
Post(VFD) ........................................................................................ 20
597212002x20RemoteCustomerDisplayona8InchPost
(VFD) ................................................................................................. 21
5973InternationalVFDRemoteCustomerDisplayona16
InchPost ........................................................................................... 22
5973InternationalVFDRemoteCustomerDisplayona8
InchPost ........................................................................................... 23
5953DynaKey .................................................................................. 24
5953K023TableTopMount.......................................................... 25
5964w/CustomerDisplay .............................................................. 28
Keyboards......................................................................................... 30
Printers.............................................................................................. 32
ComponentWeights.............................................................................. 35
ShippingWeightEstimate.............................................................. 36
AirflowRequirements ........................................................................... 37
ElectricalRequirements......................................................................... 38
PeripheralPowerRequirements ................................................... 38

vii

CableRouting

39

SystemCables

40

PrinterCables ......................................................................................... 40
PoweredUSB ................................................................................... 40
PoweredUSB(PowerOnly)........................................................... 40
RS232(9Pinto9Pin) .................................................................... 41
RS232(9Pinto25Pin) .................................................................. 41
ScannerCables........................................................................................ 42
7872or7875Scanner/Scale(RS232) ............................................. 42
7892Scanner(PoweredRS232) .................................................... 42
7882Scanner(PoweredRS232) .................................................... 43
7837Scanner(PoweredRS232) .................................................... 43
DisplayCables........................................................................................ 44
VGADisplay,RemoteExtension,Mono...................................... 44
VGADisplay,Color ........................................................................ 44
CRTACPowerExtension .............................................................. 45
59825InchLCD .............................................................................. 45
5953DynaKey .................................................................................. 45
5953DynaKeyw/Insert .................................................................. 46
5972VFDCustomerDisplay(PoweredRS232) ......................... 46
5972LCDCustomerDisplay(PoweredRS232) ......................... 47
WedgeKeyboardYCable .............................................................. 47
DVItoDVI........................................................................................ 48
PoweredUSB(12V)for5953......................................................... 48
12.1InchLCDPowerCable ........................................................... 48
PS/2RS232&Power .................................................................... 49
WedgeKeyboardAdapter ............................................................. 49
CashDrawerCables .............................................................................. 50

viii

DualCashDrawer,YCable........................................................... 50
CashDrawer,ExtensionCable ...................................................... 50
CommunicationsCable ......................................................................... 51
Ethernet,10/100BaseT ..................................................................... 51
KeyboardCables .................................................................................... 51
PS/2KeyboardExtension ............................................................... 51
PS/2YCable ..................................................................................... 52
SignatureCapture/ElectronicPaymentTerminalCable .................. 52
5945/5992EPT(RS232w/Power).................................................. 52
PowerCables .......................................................................................... 53
ACPower.......................................................................................... 53
EnvironmentalRequirements

54

BarometricPressure............................................................................... 54
Temperature ........................................................................................... 54
Humidity................................................................................................. 54

Revision Record
Issue

Date

Remarks

June2002 Firstissue

Apr2003 Added5973InternationalVFDCustomerDisplay,
595210.4InchDynaKey,595312.1InchUSB
DynaKey,5942PowerCable

Sept2003 Release1.2

NCR RealPOS 80c Site Preparation


Introduction
Thisdocumentprovidestheinformationnecessarytoprepareasiteto
NCRspecificationspriortoinstallinganNCRRealPOS80cterminal
(alsoreferredtoastheNCR7456).Thesitemustbeproperlyprepared
beforetheterminalisinstalled,becausesitepreparationdeficiencies
maybedifficulttodetectandcorrectafterinstallation.
TheNCR7456consistsofseparatepiecesthatmaybecombinedina
varietyofconfigurations.TheSystemConfigurationDiagramsection
identifiestheindividualcomponents.Certaincombinationsare
mutuallyexclusive.Youmustdeterminetheequipmentthatwill
actuallybeinstalledbeforeproceedingwiththesitepreparation.

NCR RealPOS 80c Terminal Site Preparation

Related Site Preparation Documents


AC Power and Communications Wiring
Title

Order Number

NCREthernetCommunicationWiringGuide

BST0211882

NCRTerminalandPeripheralsACWiringGuide

BST0211553

Title

Order Number

NCR7194ThermalReceiptPrinterOwnersGuide

B00500001098

NCR5945ElectronicPaymentTerminalUser
Manual

B00500001104

NCR5992SignatureCaptureTerminaluserGuide

B00500001108

NCR5932KeyboardUsersGuide

BD201369A

NCR594212.1InchLCDMonitorUsersGuide

B00500001394

Peripherals

NCR595210.4InchWedgeDynaKeyUsersGuide BD201370A
NCR595312.1InchDynaKeyUserGuide

B00500001161

NCR5964LCDDisplayUsersGuide

B00500001324

NCR59722x20CustomerDisplayUsersGuide

BD201372A

NCR5973InternationalVFDCustomerDisplay
UsersGuide

B00500001162

NCR5982LCDOperatorDisplayUserGuide

BD201443A

NCR7158ThermalReceipt&ImpactSlipPrinter
OwnersGuide

B00500001112

NCR7197ReceiptPrinterOwnersGuide

B00500001409

NCR RealPOS 80c Terminal Site Preparation

Title

Order Number

NCR7162PrinterSetup&UsersGuide

BD201453A

NCR7167TwoStationPOSPrinterOwnersGuide B00500001406
NCR7875Scanner/ScaleUsersGuide

BD201062A

NCR7872Scanner/ScaleUserGuide

B00500001179

NCR7882ScannerUserGuide

B00500001305

NCR7892PresentationScannerUserGuide

B00500001179

Where to Obtain Information Products


InformationProductsareavailableinelectronicformatfromthe
followingwebsites.
Web Sites
http://www.info.NCR.COM(WorldWideWeb)

http://inforetail.AtlantaGA.NCR.COM(NCRIntranet)

NCR RealPOS 80c Terminal Site Preparation

Customer Responsibilities
Beforethesystemcanbeinstalled,thecustomermustperformor
providethefollowing:

WhenrequiredbyNCR,providetheNCRCustomerServices
representativewithappropriatedrawingsthatindicate:

Equipmentlocation

Sitewiring(powerandcommunications,pathsandlengths)

Locationofotherequipmentthatmaygenerateelectricalnoise,
electromagneticinterference,orheat

Makebuildingalterationsnecessarytomeetwiringandothersite
requirements

Provideandinstallallcommunicationscables,walljacks,special
connectors,andassociatedhardware

Provideandinstallnecessarypowerdistributionboxes,conduits,
grounds,lightningprotectiondevices,andassociatedhardware

Ensureallapplicablecodes,regulations,andlaws(including,but
notlimitedto,electrical,building,safety,andhealth)aremet

Provideandinstallauxiliarypowerorotherequipmentasrequired

Providestorageorserviceareasasrequired

Meetallsystem/unitenvironmentalrequirements

Provideandinstallfloorcoveringsandenvironmentsystemsthat
limitorcontrolstaticelectricitybuildupanddischarge

Ingeneral,keeptheNCRequipmentareafreefromdust,smoke,lint,
andotherparticles.Restrictsmoking,eating,anddrinkingaroundthe
equipment.Avoidlocatingtheequipmentnearothermachinesthat
generateink,carbon,andpaperdustparticles.

NCR RealPOS 80c Terminal Site Preparation

AC Store Wiring Requirements


ThecustomermustprovidesuitableACpowerfortheterminals,
associatedequipment,anddevices.Adedicatedunswitchedpower
linededicatedtotheNCRequipmentinstallationisrecommended.
RefertotheNCRTerminalandPeripheralsACWiringGuide
(BSTO211553)forstoreACwiringrequirements.TheACoutletmust
beinstalledneartheterminalandeasilyaccessibletotheoperator.

LAN Communications
TheNCR7456TerminalsupportsEthernet10/100baseTLocalArea
Network(LAN)communicationprotocol.ForEthernet
communicationswiringspecifications,refertotheNCREthernet
CommunicationWiringGuide(BST0211882).

NCR RealPOS 80c Terminal Site Preparation

System Configuration Diagrams


7892

7837

7837

7892

CRT

5972-1xxx/5973

5964
Touch Screen

5952/5953
Dynakey

5972-2xxx

5942
PS/2 Keyboard

PS/2 Keyboard
5982
PCI LCD Card DVI

RS-232
(Powered)

VGA AC

USB

USB
Daughter
(4/6)

7167

Card

7197

Audio Out
Mic

LAN

Motherboard

5932 USB
2nd Drawer (Y-Cable)

Cash
Drawer

2182

2189

5932 Big Ticket

Parallel

5932 64-Key
PS/2

RS-232

RS-232
RS-232
(Powered) (Powered)

PS/2

RS-232 Peripherals

RS-232 Peripherals (Powered)

7875

7882

7162

7197
7167

5945
5992

7892

7837
19710a

NCR RealPOS 80c Terminal Site Preparation

Handling System Components


Onepersoncanmoveterminalsystemcomponents.However,consider
thefollowingwhenmovingtheterminalorhandlingindividual
components.

Peripheralsdonotattachtothebaseunitandmayslideoffifthe
baseunitistipped.

Thekeyboarddoesnotattachtothedrawerunitandmayslideoff
ifthedrawerunitistipped.

DonotturntheCRTsorcustomerdisplaysupsidedownwhile
holdingonlythedisplaymountingstand.Thedisplayisnot
attachedtothestandandmayslipoutandbedamagedifturned
upsidedown.

NCR RealPOS 80c Terminal Site Preparation

Service Clearance Requirements


Device

Above
mm (in.)

Left Side
mm (in.)

Right Side
mm (in.)

Front
mm (in.)

Behind
mm (in.)

AllUnits

153(6.0)

153(6.0)

153(6.0)

Operating Clearance Requirements


Device

Above
mm (in.)

Left Side
mm (in.)

Right Side
mm (in.)

Front
mm (in.)

Behind
mm (in.)

TerminalBase

100(4.0)

100(4.0)

100(4.0)

Keyboard

100(4.0)

CashDrawer

330(13.0)

7158Printer

325(13.0)

300(12.0)

100(4.0)

25(1.0)

7162Printer

325(13.0)

300(12.0)

100(4.0)

25(1.0)

7167Printer

305(12)

305(12)

7197Printer

267(10.5)

595312.1inch
DynaKey

50(2)

25(1)

100(4)

596412.1inch
TouchLCD

50(2)

25(1)

100(4)

CRTDisplay

50(2.0)

64(2.5)

64(2.5)

15InchCRT

50(2.0)

150(6.0)

150(6.0)

50(2.0)

59722x20Display

25(1.0)

25(1.0)

59825InchLCD
Display

25(1.0)

64(2.5)

NCR RealPOS 80c Terminal Site Preparation

Component Dimensions
Integrated Configurations
Theintegrateddisplaysaremountedonadjustablearms.Inthe
illustrationsfollowingboththeminimumandmaximumwidth
dimensionsareshown.

5942 LCD Operator Display


508 mm
(20.0 in.)
320 mm
(12.6 in.)

480 mm
(19.0 in.)

320 mm
(12.6 in.)

20734

10

NCR RealPOS 80c Terminal Site Preparation

5972 2x20 Customer Display

500 mm
(19.5 in.)

20735

187 mm
(7.35 in.)
535 mm
(21.0 in.)

NCR RealPOS 80c Terminal Site Preparation

11

5953 DynaKey
670 mm
(26.25 in.)
520 mm
(20.5 in.)

460 mm
(18.25 in.)

20732

320 mm
(12.6 in.)

12

NCR RealPOS 80c Terminal Site Preparation

9-Inch CRT
480 mm
(19.0 in.)
420 mm
(16.5 in.)

480 mm
(19.0 in.)

320 mm
(12.6 in.)

20733

Base Unit

108 mm
(4.25 in.)

401 mm
(15.8 in.)
320 mm
(12.6 in.)

19715

NCR RealPOS 80c Terminal Site Preparation

13

Cash Drawers
NCR 2182
400 mm
(15.75 in.)

108 mm
(4.25 in.)
450 mm
(17.7 in.)

Operating and Service


Clearance for Drawer
254 mm
(10.0 in.)
15413

NCR 2189
464 mm
(18.25 in.)

133 mm
(5.25 in.)
527 mm
(20.5 in.")

Operating and Service


Clearance for Drawer
330 mm
(13.0 in.)

20434

14

NCR RealPOS 80c Terminal Site Preparation

NCR 2183

455 mm
(17.9 in.)

108 mm
(4.25 in.)
450 mm
(17.7 in.)

Operating and Service


Clearance for Drawer
263 mm
(10.4 in.)
18038

NCR RealPOS 80c Terminal Site Preparation

15

Displays
7452-K309 9-Inch Monochrome CRT (497-0418913)

240 mm
(9.5 in.)

247 mm
(9.75 in.)

248 mm
(9.75 in.)

19718

16

NCR RealPOS 80c Terminal Site Preparation

7452-K404 9-Inch Monochrome CRT (497-0418913)

240 mm
(9.5 in.)

247 mm
(9.75 in.)

297 mm
(11.7 in.)

14339

NCR RealPOS 80c Terminal Site Preparation

17

7452-K419 15-Inch Monochrome CRT (497-0414126)

361 mm
(14.2 in.)

318 mm
(12.5 in.)

381 mm
(15 in.)

368 mm
(14.5 in.)

17386

18

NCR RealPOS 80c Terminal Site Preparation

5982 5-Inch Monochrome LCD Operator Display

176 mm
(6.9 in.)

128 mm
(5 in.)

16 mm
(0.7 in.)

165 mm
(6.5 in.)

140 mm
(5.5 in.)

112 mm
(4.5 in)

15411

NCR RealPOS 80c Terminal Site Preparation

19

5972/5973 2x20 Remote Customer Display on a Short Mount (VFD)

262 mm
(10.3 in.)

119 mm
(4.7 in.)

30 mm
(1.2 in.)

162 mm
(6.4 in.)

178 mm
(7.0 in.)

173 mm
(6.8 in.)
17241

20

NCR RealPOS 80c Terminal Site Preparation

5972-1200 2x20 Remote Customer Display on a 16-Inch Post (VFD)

30 mm
(1.2 in.)

262 mm
(10.3 in.)

119 mm
(4.7 in.)
561 mm
(22.1 in.)

95 mm
(3.75 in.)

95 mm
(3.75 in.)

15708

NCR RealPOS 80c Terminal Site Preparation

21

5972-1200 2x20 Remote Customer Display on a 8-Inch Post (VFD)

262 mm
(10.3 in.)

119 mm
(4.7 in.)

95 mm
(3.75 in.)

30 mm
(1.2 in.)

356 mm
(14.1 in.)

356 mm
(14.1 in.)

95 mm
(3.75 in.)

20131a

22

NCR RealPOS 80c Terminal Site Preparation

5973 International VFD Remote Customer Display on a 16-Inch Post

30 mm
(1.2 in.)

262 mm
(10.3 in.)

119 mm
(4.7 in.)
561 mm
(22.1 in.)

95 mm
(3.75 in.)

95 mm
(3.75 in.)

15708

NCR RealPOS 80c Terminal Site Preparation

23

5973 International VFD Remote Customer Display on a 8-Inch Post

262 mm
(10.3 in.)

119 mm
(4.7 in.)

95 mm
(3.75 in.)

30 mm
(1.2 in.)

356 mm
(14.1 in.)

356 mm
(14.1 in.)

95 mm
(3.75 in.)

20131a

24

NCR RealPOS 80c Terminal Site Preparation

5953 DynaKey
470 mm
(18.5 in.)

300 mm
(11.7 in.)

255 mm
(10.0 in.)

20051

470 mm
(18.5 in.)
263 mm
(10.3 in.)

420 mm
(16.5 in.)

255 mm
(10.0 in.)

366 mm
(14.5 in.)

20052

NCR RealPOS 80c Terminal Site Preparation

5953-K023 Table-Top Mount


TheTableTopMountisfullyadjustablebetweentheminimumand
maximumdimensionsthatareillustratedbelow.TheDynaKeycan
alsoberotatedrightandleftofcenter(shown)byapproximately90
degrees,aswellastiltedfromaverticalpositiontoapproximately45
degrees(shown).

114 mm
4.25 in.

370 mm
(14.5 in.)

38 mm
1.5 in.

89 mm
3.5 in.

70 mm
2.75 in.

7.6.mm
0.30 in.
330 mm
(13.0 in.)

480 mm
(19.0 in.)

216 mm
(8.5 in.)

400 mm
(15.75 in.)

213 mm
(8.4 in.)

19909

25

26

NCR RealPOS 80c Terminal Site Preparation

TherearetwopositionstoinstalltheposttothebackoftheDynaKey.
270 mm
(10.75 in.)

140 mm
5.5 in.
105 mm
4.13 in.

200 mm
(8.0 in.)

19908

NCR RealPOS 80c Terminal Site Preparation

27

5964 12.1-Inch Touch LCD


(348 mm)
13.7 in.

(297 mm)
11.7 in.

(252 mm)
9.9 in.
19555

Tilt/Swivel Dimensions
Hinge Tilt Angle
87.6

Swivel Angle
88.0

Swivel Angle
88.0
20305

28

NCR RealPOS 80c Terminal Site Preparation

5964 w/Customer Display

16.6 in.
(42.2mm)

13.7 in.
(348 mm)

12.9 in.
(328 mm)

19557

NCR RealPOS 80c Terminal Site Preparation

29

5942 12.1-Inch LCD Monitor

306 mm
(12.0 in.)

304 mm
(11.9 in.)

47 mm
(1.9 in.)
13 mm
(0.5 in.)

190 mm
(7.5 in.)

133 mm
(5.25 in.)
165 mm
(6.5 in.)
19810

30

NCR RealPOS 80c Terminal Site Preparation

Keyboards
5932 Big Ticket POS Keyboard
179 mm
(7 in.)

455 mm
(17.9 in.)

45 mm
(1.75 in.)

20 mm
(.8 in.)
11412

11413

5932 64-Key POS Keyboard


184 mm
(7.2 in.)

335 mm
(13.2 in.)

42 mm
(1.7 in.)

NCR RealPOS 80c Terminal Site Preparation

31

5932 USB Big Ticket POS Keyboard

184 mm
(7.2 in.)

455 mm
(17.9 in.)

42 mm
(1.7 in.)

19716

32

NCR RealPOS 80c Terminal Site Preparation

Printers
7158 Thermal Receipt and Impact Slip Printer

165 mm
(6.5 in.)

305 mm
(12.0 in.)

336 mm
(13.25 in)

229 mm
(9.0 in)
17307

7162 Dot Matrix Slip Printer

191 mm
(7.5 in.)

142 mm
(5.6 in.)

250 mm
(11.7 in.)

297 mm
(11.7 in.)

15410

NCR RealPOS 80c Terminal Site Preparation

33

7167 Thermal Receipt and Impact Slip Printer

174 mm
(7.0 in.)

262 mm
(10.3 in.)

275 mm
10.8 in.

190 mm
(7.5 in.)

316 mm
(12.5 in.)

19711b

7194 Thermal Receipt Printer

156 mm
(6.25 in.)

184 mm
(7.25 in.)

255 mm
10.1 in.

146 mm
(7.75 in.)
19712c

34

NCR RealPOS 80c Terminal Site Preparation

7197 Thermal Receipt Printer

Top Cover Open


256 mm
(10.1 in.)
156 mm
(6.25 in.)

184 mm
(7.25 in.)

146 mm
(7.75 in.)
19712c

NCR RealPOS 80c Terminal Site Preparation

35

Component Weights
Terminal Component

Weight kg

(lbs.)

Baseunitw/Batteries

10.7

(23.5)

Baseunitw/oBatteries

8.8

(19.3)

IntegratedBase;w/oPeripherals,w/Batteries

13.0

(35.0)

IntegratedBase;w/oPeripherals,w/oBatteries

10.7

(28.8.)

2182Cashdrawer

6.2

(13.7)

2183Cashdrawer

11.4

(25.15)

2189Cashdrawer

9.5

(20.9)

64Keykeyboard

0.9

(1.9)

BigticketPOSkeyboard

1.4

(3)

9InchCRTDisplay

4.3

(9.4)

15InchCRTDisplay

11.9

(26.5)

59825InchLCDDisplay

0.8

(1.8)

59721000Customerdisplay

0.7

(1.5)

59722300Customerdisplay

0.7

(1.5)

5973InternationalVFDCustomerDisplay

0.7

(1.5)

Displaymountingstand

4.3

(9.5)

5953DynaKeymodule

3.4

(7.5)

594212.1InchLCDMonitor

2.8

(6.2)

596412.1InchTouchLCD

4.7

(10.4)

7167Receipt/ImpactPrinter

4.5

(10.0)

36

NCR RealPOS 80c Terminal Site Preparation

Terminal Component

Weight kg

(lbs.)

7197ThermalReceiptPrinter

1.5

(3.4)

7158Printer(withMICRandcheckflip)

4.9

(10.8)

7162Printer

5.8

(12.7)

7194Thermalreceiptprinter

1.4

(3)

Flexdiskdriveanddatacables

0.4

(0.9)

3.5InchHarddiskdrive(20GB)withmount

0.5

(1.0)

Shipping Weight Estimate


Toobtainthetotalmaximumweightofaspecificconfiguration,add
theweightsoftheappropriateindividualcomponents.Thefollowing
tableprovidesanexample.
Terminal Component

Weight kg

(lbs.)

IntegratedBaseunitw/Batteries

13.0

(35.0)

594212.1InchLCDMonitor

2.8

(6.2)

59721xxxCustomerdisplay

0.7

(1.5)

64Keykeyboard

0.9

(1.9)

7167Receipt/ImpactPrinter

4.5

(10.0)

Total

21.9

(5460)

Miscellaneousitemsandshippingmaterials

5.2

(11.5)

27.1

(66.1)

Shippingtotal

NCR RealPOS 80c Terminal Site Preparation

37

Airflow Requirements
Donotblocktheairventsontheterminalorperipherals.Thesevents
arenecessaryforcooling.

19717

Donotplacetheterminalinanenclosedareawheresufficient
ventilationisnotavailable.Leaveatleast100mm(4inches)of
clearanceonsideswhereairventsarelocated.

38

NCR RealPOS 80c Terminal Site Preparation

Electrical Requirements
Theterminalspowercordplugsintothebackoftheterminalandinto
athreewire,singlephase,120or240VACreceptacle.Theavailable
powercordsaredescribedintheSystemCablessection.
Theterminalsinternalpowersupplyhasamaximumoutputof237
Wattsandprovidespowertotheterminal,oneprinter,and
peripherals.Additionally,anACpowersocketisavailableontheback
oftheterminalforaCRT.

Maximum Terminal Power Usage


120 Volt System

240 Volt System

VoltageRange

90136VAC

180265VAC

Frequency

50/60Hz

50/60Hz

Current

4.6Amps

2.3Amps

Peripheral Power Requirements


Thenumberofperipheralsthattheterminalcansupportisdependent
uponwhichperipheralsareconnected.Forplanningpurposes,usethe
RealPOS80cPowerMatrix(B00500001526)tocalculatethepower
requirementsforyourspecificsystemconfiguration.
Note: ThisfilerequiresMicrosoftExceltorun.

NCR RealPOS 80c Terminal Site Preparation

39

Cable Routing
CableconnectorsarelocatedinthebackoftheBaseUnit.
AC Input

Accessory AC

Audio Out

Mic

12V USB

* RS232/C

RS232/C

RS232/D

RS232/A

RS232/B

Mic

24V USB

Cash Drawer

24V

Audio
Out

VGA

DVI-1

Parallel

LAN

PS/2

* RS232/D

* RS232/A
* Powered Serial Port

RS232/B

VGA

DVI-1

Parallel

LAN

PS/2
19531

40

NCR RealPOS 80c Terminal Site Preparation

System Cables
Printer Cables
Powered USB
497-0424888 - 1 m
(1416-C713-0010)
497-0424501 - 4 m
(1416-C713-0040)
USB (Printer)
24V USB+
(Terminal)

Power (Printer)

19.0 mm
(0.75 in.)

Access Hole Diameters

23.0 mm
(0.9 in.)
19307

Powered USB (Power Only)


497-0424887 - 1m
1416-C712-0010
497-0422292 - 4m
1416-C712-0040
Power
(Printer)

24V USB+
(Terminal)

19.0 mm
(0.75 in.)

Access Hole Diameters

23.0 mm
(0.9 in.)

19721

NCR RealPOS 80c Terminal Site Preparation

41

RS-232 (9-Pin to 9-Pin)


497-0408349 - 0.7 m
(1416-C359-0007)
497-0407943 - 4 m
(1416-C266-0040)

9-pin
D-shell
Receptacle
RS-232
(Printer)

38.0 mm
(1.5 in.)

9-pin
D-shell
Receptacle
RS-232
(Terminal)

Access Hole Diameters

38.0 mm
(1.5 in.)

19722

RS-232 (9-Pin to 25-Pin)


497-0407427 - 1.0 m
(1416-C337-0010)
497-0407429 - 4 m
(1416-C337-0040)
25-pin
D-shell
Plug

9-pin
D-shell
Receptacle
RS-232
(Terminal)

38 mm
(1.5 in.)

RS-232
(Printer)

Access Hole Diameters

63.5 mm
(2.5 in.)
20127a

42

NCR RealPOS 80c Terminal Site Preparation

Scanner Cables
7872 or 7875 Scanner/Scale (RS-232)
D-Shell
9-Pin
Receptacle

497-0300422 - 4 m
(1416-C019-0040)

Modular
10-Pin
Plug
RS-232
(Scanner)

RS-232
(Terminal)

38.0 mm
(1.5 in.)

Access Hole Diameters

19.0 mm
(0.75 in.)

15479

7892 Scanner (Powered RS-232)

D-Shell
9-Pin
Receptacle

497-0425593 - 3.0 m
(1416-C643-0030)

RS-232
(Terminal)

Modular
10-Pin
Plug
Scanner

38.0 mm
(1.5 in.)

Access Hole Diameters

32.0 mm
(1.25 in.)
20450

NCR RealPOS 80c Terminal Site Preparation

43

7882 Scanner (Powered RS-232)

D-Shell
9-Pin
Receptacle

497-0419723 - 4.0 m
(1416-C653-0040)

Modular
10-Pin
Plug

RS-232
(Terminal)

Scanner

38.0 mm
(1.5 in.)

Access Hole Diameters

19.0 mm
(0.75 in.)
19728

19724

7837 Scanner (Powered RS-232)

D-Shell
9-Pin
Receptacle

497-0412952 - 2.5 m
(1416-C430-0025)

RS-232
(Terminal)

Modular
10-Pin
Plug
Scanner

38.0 mm
(1.5 in.)

Access Hole Diameters

19.0 mm
(0.75 in.)

44

NCR RealPOS 80c Terminal Site Preparation

Display Cables
VGA Display, Remote Extension, Mono
Sub Miniature D-Shell
15-Pin
Plug

497-0008164 - 4 m
1416-C042-0040

Sub Miniature D-Shell


15-Pin
Receptacle
VGA
(CRT Display)

VGA
(Terminal)

38.0 mm
(1.5 in.)

38.0 mm
(1.5 in.)

Access Hole Diameters

14607

VGA Display, Color


1.0 m Black 497-0428080

1416-C840-0010

1.5 m Black 497-0428068

1416-C839-0015

1.0 m White 497-0424530

1416-C753-0015

1.5 m White 497-0424531

1416-C754-0010
Sub Miniature D-Shell
15-Pin Receptacle

Sub Miniature D-Shell


15-Pin Plug

VGA
(CRT Display)

VGA
(Terminal)

38.0 mm
(1.5 in.)

Access Hole Diameters

38.0 mm
(1.5 in.)
16318

NCR RealPOS 80c Terminal Site Preparation

45

CRT AC Power Extension


497-0406237 - 4m
(1416-C508-0040)

45.0 mm
(1.75 in.)

Access Hole Diameters

45.0 mm
(1.75 in.)
19741

5982 5-Inch LCD


Champ
50-pin Plug

497-0409750 - 4m

24-pin
Minifit Plug

LCD
(PCI Card)

5982

57.0 mm
(2.25 in.)

Access Hole Diameters

44.0 mm
(1.75 in.)
19731

19847

5953 DynaKey
497-0414885 - 1 m
(1416-C482-0010)
50-pin
Amplimite
Plug

497-0413878 - 4 m
(1416-C482-0040)

50-pin
Amplimite
Plug
5953

LCD
(PCI Card)

57.0 mm
(2.25 in.)

Access Hole Diameters

57.0 mm
(2.25 in.)

46

NCR RealPOS 80c Terminal Site Preparation

5953 DynaKey w/Insert


497-0419053 - 1 m
(1416-C647-0010)
50-pin
Amplimite
Plug

497-0419054 - 4 m
(1416-C647-0040)

50-pin
Amplimite
Plug

LCD
(PCI Card)

5953

57.0 mm
(2.25 in.)

Access Hole Diameters

57.0 mm
(2.25 in.)
19846

5972 VFD Customer Display (Powered RS-232)


497-0420926 - 1 m
1416-C683-0010
9-pin
D-Shell
Receptacle

497-0420927 - 4 m
1416-C683-0040

24-Position
Microfit
Receptacle
Customer
Display

Terminal
RS-232 Port

25.4 mm
(1.0 in.)

35 mm
(1.5 in.)
Access Hole Diameters

20279a

NCR RealPOS 80c Terminal Site Preparation

47

5972 LCD Customer Display (Powered RS-232)


497-0420928 - 1.0 m
(1416-C684-0010)
9-pin
D-shell
Receptacle

497-0420929 - 4.0 m
(1416-C684-0040)

12-Position
Microfit
Receptacle
Customer
Display

RS-232
(Terminal)

25.4 mm
(1.0 in.)

35 mm
(1.5 in.)
Access Hole Diameters

20281a

Wedge Keyboard Y-Cable


9-pin
D-shell
Receptacle

497-0407490 - 0.5 m
(1416-C338-0005)

RS-232
(Terminal)

6-pin
Mini-DIN
Plug
PS/2
(PCI LCD Card)
5-pin
Mini-DIN
Plug
Kybd
(Terminal)

38.0 mm
(1.5 in.)

Access Hole Diameters

19.0 mm
(0.75 in.)
19733

48

NCR RealPOS 80c Terminal Site Preparation

DVI to DVI
497-0422831 - 1.0 m
(1416-C723-0010)

24-Pin
DVI-D Plug

24-Pin
DVI-D Plug

497-0422832 - 4.0 m
(1416-C723-0040)
DVI
(Terminal)

DVI
(Display)

63.5 mm
(2.5 in.)

63.5 mm
(2.5 in.)

Access Hole Diameters

19725

Powered USB (12 V) for 5953


497-0424838 - 1.0 m
(1416-C757-0010)
497-0424839 - 4.0 m
(1416-C757-0040)
Powered USB
(5953)

Powered USB
(Terminal)
20059

12.1-Inch LCD Power Cable


497-0426160 - 4 m (White)
1416-C803-0040
497-0428512 - 4 m (Black)
1416-C803-0040
Power
(Display)

USB
Powered USB
(Terminal)
20444

NCR RealPOS 80c Terminal Site Preparation

49

PS/2 - RS-232 & Power


497-0422833 - 1m
(1416-C725-0010)
497-04222834 - 4m
(1416-C725-0040)

RS-232
(Terminal)

12 V COM
(5964)

PS/2
(Terminal)

38.0 mm
(1.5 in.)

Access Hole Diameters

38.0 mm
(1.5 in.)
19734

Wedge Keyboard Adapter


6-pin
Mini-DIN
Plug

497-0406868

PS/2
(Terminal)
19.0 mm
(0.75 in.)

5-pin
Mini-DIN
Plug
LCD
(PCI Card)

Access Hole Diameters

19.0 mm
(0.75 in.)

19735

50

NCR RealPOS 80c Terminal Site Preparation

Cash Drawer Cables


Dual Cash Drawer, Y-Cable
497-0409394 - 0.6 m
(1416-C372-0006)

Cash
DWR. #1

Cash Drawer
(Terminal/Printer)
Cash
DWR. #2
16.0 mm
(0.63 in.)

51.0 mm
(2.0 in.)

Access Hole Diameters

15808

Cash Drawer, Extension Cable


Modular
6-Pin Plug

230-0145735 - 3.0 m
(1424-C112-0030)

Cash Drawer
(Terminal/Printer)

16.0 mm
(0.63 in.)

Modular
6-Pin Jack
Cash Drawer
(Cable)

Access Hole Diameters

30.0 mm
(1.2 in.)
19730

NCR RealPOS 80c Terminal Site Preparation

51

Communications Cable
Ethernet, 10/100BaseT
497-0008905 - 3.0 m
(1416-C059-0030)

Modular
8-Pin
Plug

19.0 mm
(0.75 in.)

Access Hole Diameters

Modular
8-Pin
Plug

19.0 mm
(0.75 in.)
16298

Keyboard Cables
PS/2 Keyboard Extension
6-pin
Mini-DIN
Plug

497-0406056 - 1.8 m
(1416-C281-0018)

PS/2
(Terminal)

6-pin
Mini-DIN
Receptacle
PS/2
(Keyboard)

19.0 mm
(0.75 in.)

Access Hole Diameters

19.0 mm
(0.75 in.)
15403

52

NCR RealPOS 80c Terminal Site Preparation

PS/2 Y-Cable

6-pin
Mini-DIN
Plug

497-0414489 - 0.2 m
1416-C542-0002)
51 mm
(2 in.)

PS/2
(Terminal)

6-pin
Mini-DIN
Receptacle
PS/2
(Mouse)
5-pin
Mini-DIN
Receptacle
PS/2
(Keyboard)
17894a

19723

Signature Capture/Electronic Payment Terminal Cable


5945/5992 EPT (RS-232 w/Power)
9-pin
Mini-DIN
Plug

497-0418406 - 4.0 m
(1416-C634-0040)

9-pin
D-shell
Receptacle

RS-232
(EFT Unit)

RS-232
(Terminal)

19 mm
(0.75 in.)

Access Hole Diameters

63.5 mm
(2.5 in.)

NCR RealPOS 80c Terminal Site Preparation

53

Power Cables
AC Power
006-1009037 - U.S.
Terminal
The following power cables (not shown)
also have an IEC connection of 45 mm:
006-8601001 - Japan Twist-Lock
006-8601010 - International
006-8601011 - SEV
006-8601012 - U.K.
006-8601019 - Australia

Access Hole Diameter

45 mm
(1.75 in.)
15405

54

NCR RealPOS 80c Terminal Site Preparation

Environmental Requirements
Barometric Pressure
Theterminaloperateswithinthefollowingbarometricpressure
conditions:

Maximumoperatingaltitude:3,000m(9,843ft.)

Operatingrangeofpressure:105to69kPa(15.2to10.0lb./in.)

Temperature
Theterminaloperatesoverthetemperaturerangesshownbelow.
Continuousoperationmustbeavoidedatorneartheindicated
temperatureextremesorinlocationswherethetemperaturechanges
beyondtherestrictions.
Temperature Parameter

Restriction

Operating

5Cto45C(41Fto113F),drybulb

Storage

10Cto50C(14Fto122F),threemonths

Shipping

40Cto60C(40Fto140F),oneweek

DewPoint

26C(79F)maximum

Humidity
Theterminaloperateswithinthehumidityrangesshownbelow.
Continuousoperationmustbeavoidedatorneartheindicated
humidityextremesorinlocationswherethehumiditychangesbeyond
therestrictions.Neverexposetheterminaltocondensation.
Humidity Type

Restriction

Relative

10%to90%

Maximumchangerate 10%/60minutes

Storage

10%to90%relativehumidity,threemonths

Shipping

5%to95%relativehumidity,oneweek

Appendix A: Transient Protection


AC Power Line Transient Protection
Intheprocessofpowerdistribution,transientelectricalenergy
(including,butnotlimitedto,lightningstrikes,intermittentshort
circuits,andswitchingtransients)canbeintroducedontopowerlines.
Suchtransientenergycanbeverydamagingtoelectronichardware,
andcanalsocausedatacorruption.Underthesecircumstances,NCR
recommendstheuseofACpowertransientsuppressors.Such
protectiondevicesareintendedtoguardagainstpowerlinetransients
thatcanresultinhardwaredamageandvarioussystemorprogram
errors.
Improvementofanydeficienciesinpowerqualityisacustomer
responsibility.Malfunctionand/orcomponentfailureasaresultof
powerqualityproblemsare/isnotcoveredbytheNCRMaintenance
Agreement.NCRacceptsnoliabilityforanysuchoccurrencenorforits
consequences.
Whenpowertransientsuppressionisrequired,thesuppressorsused
shouldmeetthefollowingminimumrequirements:

Dissipateenergytomatchtheappropriateapplicationcategoriesas
definedbyIEEEStandard587.

Beofthevoltagelimiting(clipping),ortrackingfiltertype.The
suppressormustnotclampthevoltagetozero,andmustself
recoverafterthepassageofthetransient.Thesuppressormaybeof
thehybridtypeconstructionthatmakesuseofvarioustechnologies
inordertomeetspeedanddissipationrequirements.

A-2

Appendix A: Transient Protection

Uponfailure,exhibitapositiveindicationofitsfailuresuchasa
blownfuseortrippedbreaker.

Belistedbytheacceptedsafetyorganizationforthecountry
involved(UL,CSA,VDE,ETL,andsoon)andtheinstallationmust
conformtolocal,state,andnationalelectricalcodesand
regulations.

Data Line Transient Protection


Thenatureofthetransientphenomenonmayextendtothedata
communicationlinesconnectedtothisequipment.Itisthe
responsibilityofthecustomertoinstallandconnectadataline
transientsuppressionsystemtocorrectorpreventanydeficiencies.
Suchsystemsmustmeetthefollowingminimumrequirements:

Beofthevoltagelimitingtypeandmustselfrecoverafterpassage
ofthetransient.

Insertlessthan5ohmsresistanceandminimalinductiveand
capacitiveloadingattheoperatingfrequencyfordatalines,in
ordertoavoidsignaldegradation.

Beinstalledinaccordancewithallapplicablelocal,state,and
nationalelectricalcodesandregulation.

Note: Incertaincountries,NCRisabletosupplybothpoweranddata
linetransientsuppressorsaswellasacomprehensivelineofpower
conditioningequipment.Forapplicationdata,contactyourNCR
CustomerServicesDivisionRepresentative.

Das könnte Ihnen auch gefallen