Sie sind auf Seite 1von 179

Standard Products

Water Treatment
Standard Products
Water Treatment
S T A N D A R D P R O D U C T S
Veolia Water Solutions & Technologies (VWS), subsidiary of Veolia
Water, is a specialised provider of technological solutions in water
treatment.
All standard products oered by VWS are manufactured to strict
quality standards, using the best materials.
Standard products have short lead times and can be quickly
installed on site. Many are modular in design and as such are easily
integrated into existing plant.
VWS manufacturing units can provide engineered systems to meet
specic needs. Standard products may also be congured for higher
ow rates, water qualities, etc.
All technologies are supplied and supported by local VWS subsidiaries.
Veolia Water Solutions & Technologies is continually extending and
enriching its oer in order to respond to the changing needs of its
clients.
Related Services, Consumables & Spare Parts: Local after-sales service
and support teams oer preventative and corrective maintenance
programs to ensure the long-term, ecient operation of installed
plant.
Screen & Disc Filtration
Screen and disc lters are used to remove particulate impurities from water.
Particles in water can cause problems of erosion in pumps and pipe work and can
block ne jets such as spray nozzles. Water ows through a screen or between
discs which retain particles larger than the dened ltration grade. Screen and disc
lters do a similar job to cartridge lters but the screens/discs are cleaned rather
than replaced, so operating costs are minimal.
Typical applications include:
Protection of domestic water ttings
Protection of membrane processes from fouling
Filtration of cooling water to prevent heat exchanger fouling
Pre-ltration of process water
S
c
r
e
e
n

&

D
i
s
c
F
i
l
t
r
a
t
i
o
n
Berkal
Protective Filters
Berkal disc ltration systems
remove contaminants such as
bres, grit, sand and algae.
Flow rates from 10 to 120 m
3
/hr.
Features & Benets
Compact systems with high ow
and retention capacities
Automatic backwashing of indivi-
dual lters based on time or pres-
sure dierential; continual ow,
optimised backwash water usage
Modular design, choice of ltration
grades from 20 to 400 m; highly
scalable, exible
Combines screen ltration and
depth ltration to ensure high
contaminant removal rates
Air assisted backwashing; rinse
water consumption is only 0.5% of
ltrate capacity
No consumables; low running
costs, minimal maintenance
Corrosion resistant polypropylene
pipework
Options
Filtration grades (m): 20, 50, 100,
130, 200, 400
Backwashing: air aided ushing
(standard), internal or external ushing
Piping: plastic coated steel,
stainless steel
Applications
Side stream ltration of cooling
tower water
Pre-treatment to softeners, ion
exchangers or membrane systems
Feed water for irrigation systems
Prevention of corrosion and
blockages within pipework, valves,
distributors and other equipment
Municipal wastewater
Aquaculture
Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Berkal
System Performance
Temperature and Pressure Ratings
Model
Temp. Range Pressure
Flow
Connections
Backwash
Air**
Width Height Depth
Rates*
2/1/100
2/2/100(S)
2/3/100(S)
2/4/100(S)
2/5/100(S)
2/6/100(S)
2/7/100(S)
2/8/100(S)
m
3
/hr
10-15
15-30
30-45
45-60
60-75
75-90
90-105
105-120
litres
46
46
46
46
46
46
46
46
C
5-35
5-45
5-55
5-65
5-70
bar
0.8-10
0.8-9
0.8-8
0.8-7
0.8-6.5
mm
821
955
1297
1597
1897
2155
2455
2755
mm
834
1101
1101
1129
1129
1129
1156
1156
mm
408
825
825
852
852
848
907
907
Raw
Rp 2"
DN80
DN80
DN100
DN100
DN100
DN150
DN150
Filtrate
Rp 2"
DN80
DN80
DN100
DN100
DN100
DN150
DN150
Backwash
Rp 2"
DN50
DN50
DN50
DN50
DN50
DN50
DN50
*100m lter
**per lter element at 5-6 bar
(S) S version is with high-grade steel pipe work
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkal/AQF0021_EN_V1.2
Amando
1M
ProIecIive lilIers
Amando" hlIers help Io prevenI
wear and corrosion oI
downsIream pipe work,
componenIs and connecIed
equipmenI.
llow raIes Irom 3.8 to 4.3 m
3
Jhr.
leaIures & 8enehIs
I00 m hlIer, removes sand,
oxidanIs, dissolved sedimenIs
HW5 ModeI
lnIegraIed pressure reducer,
ad|usIable Irom I.5 Io 6.0 bar,
proIecIs downsIream equipmenI
Irom excessive waIer pressures
ConIinual ow, even during
backwash
Mechanical hlIer, no consumables,
minimal mainIenance
Manual backwash using paIenIed
process, minimal waIer usage
SIainless sIeel, brass and GkP
componenIs, corrosion resisIanI
ApplicaIions
lndusIrial
DomesIic
keduce downsIream corrosion
and wear
ProIecI againsI excessive waIer
pressures
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
Ando
quipment Performance & Dimensions
. p m e 1 . a M h t p e D t h g i e H h t d i W s n o i t c e n n o C * s e t a k o I f I e d o M
k (inches) mm mm mm C
kf 20 3.8
kf 25 4.2 1
kf 32 4.3 1
HW5 20 3.8
HW5 25 4.2 1
HW5 32 1
'AI 0.2 bar Ior kl models.
for higher o rate appIications consuIt our IocaI VeoIia Water 5oIutions & 1echnoIogies compan, detaiIs beIo.
vsL cur wchsLc.
wwwveoiwtersto
n kccpng wh hc progrcssvc naurc o hc conpany wc rcscrvc hc rgh o ancnd dcas whou nocc
VWS CTOC nandoQNV
m
3
Jhr
4/3
190
190
190
190
190
190
423
413
413
463
463
463
190
190
190
190
190
190
30
30
30
30
30
30
8erko"
ProIecIive lilIers
8erko" hlIers help Io
prevenI wear and corrosion
oI downsIream pipe work,
componenIs and connecIed
equipmenI.
llow raIes Irom 3.2 to 9.0 m
3
Jhr.
leaIures & 8enehIs
I00 m hlIer as sIandard, removes
sand, oxidanIs, dissolved sedimenIs
Mechanical hlIer, no consumables,
minimal mainIenance
Manual backwash
SIainless sIeel and brass, corrosion
resisIanI
Dptions
25, 50, 250, and 500 m hlIers
ApplicaIions
lndusIrial
DomesIic
keduce downsIream corrosion
and wear
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
8erko"
quipment Performance & Dimensions
h t p e D t h g i e H h t d i W s n o i t c e n n o C s e t a k w o I f I e d o M
m
3
Jhr kp (inches) mm mm mm
Berko 2
104
136
270
297
297 108
1 130 270
135
135
135
135 2 . 3
Berko 3 5.0 1
Berko 4 8.0 1
Berko 5 2 0 . 9
AII ModeIs
r a b 0 I OperaIing Pressure . x a M
C 5 9 OperaIing 1emperaIure . x a M
for higher ow rate appIications consuIt your IocaI VeoIia Water 5oIutions & 1echnoIogies company, detaiIs beIow.
vsL cur wchsLc.
www.veo|iawaterst.com
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC/Lcrko//Q0022NV2.!
8erkohn"
ProIecIive lilIers
8erkohn" hlIers help Io
prevenI wear and corrosion
oI downsIream pipe work,
componenIs and connecIed
equipmenI.
llow raIes Irom 4.3 to !00 m
3
Jhr.
leaIures & 8enehIs
I00 m hlIer, removes sand,
oxidanIs, dissolved sedimenIs
ConIinual ow, even during
backwashing
lixed hlIer, no consumables,
minimal mainIenance
SIainless sIeel or brass hlIers,
corrosion resisIanI
Manual and auIomaIic backwash
opIions
ApplicaIions
lndusIrial
DomesIic
keduce downsIream corrosion
and wear
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
8ek"
quipment Performance & Dimensions
ModeI fIow kate* Connections (inches)
Max. Max.
Width Height Depth
Pressure 1emperature
m
3
m m m m m m C r a b e t a r t I i f w a k r h J
20 V 0 1 1 6 8 2 3 6 2 0 3 6 1 R R 5 . 4
25 V 0 1 1 6 8 2 5 4 2 0 3 6 1 1 R 1 R 0 . 6
32 V 0 1 1 6 8 2 3 6 2 0 3 6 1 1 R 1 R 0 . 9
40 V 0 1 1 6 8 2 5 7 2 0 3 6 1 1 R 1 R 0 . 9
'Nominal ow raIe aI 2 bar
1he above models are manually backwashed, have brass hlIer housings and chrome nickel sIeel hlIers.
ModeI fIow kate* Connections (inches)
Max. Max.
Width Height Depth
Pressure 1emperature
m
3
m m m m m m C r a b e t a r t I i f w a k r h J
5 20 V 97
97
97
120
120
9 4 4 8 7 1 0 7 6 1 R R 3 . 4
5 25 V 3 5 4 9 0 2 0 7 6 1 1 R 1 R 2 . 7
5 32 V 3 5 4 2 2 2 0 7 6 1 1 R 1 R 8 . 7
5 40 V 2 3 5 6 4 2 0 7 6 1 1 R 1 R 0 . 0 1
5 50 V 2 3 5 7 6 2 0 7 6 1 2 R 2 R 5 . 1 1
'Nominal ow raIe aI 2 bar
1he above models are manually backwashed, auIomaIic backwashing is possible wiIh Ihe opIional ZSA Iimer. 8rass hlIer housings and chrome nickel sIeel hlIers.
ModeI fIow kate*
. x a M . x a M s n o i t c e n n o C
Width Height
kp & k (inches) J DN (mm) Pressure 1emperature
m
3
Jhr kaw fiItrate 8ackwash bar C mm mm
VAZ 40 H
VAZ 50 H
VAZ 65 H
VAZ 80 H
VAZ !00 H
VAZ !25 H
'Nominal ow raIe aI 2 bar
1he above models are manually backwashed, have sIainless sIeel hlIer housings and chrome nickel sIeel hlIers.
ModeI fIow kate*
. x a M . x a M s n o i t c e n n o C
Width Height
kp & k (inches) J DN (mm) Pressure 1emperature
m
3
Jhr kaw fiItrate 8ackwash bar C mm mm
VAZ 40 A5Z
VAZ 50 A5Z
VAZ 65 A5Z
VAZ 80 A5Z
VAZ !00 A5Z
VAZ !25 A5Z
'Nominal ow raIe aI 2 bar
1he above models are auIomaIically backwashed (Iimer), have sIainless sIeel hlIer housings and chrome nickel sIeel hlIers.
1ouch pad conIrollers wiIh Iwo line LLD displays.
ModeI fIow kate*
. x a M . x a M s n o i t c e n n o C
Width Height
kp & k (inches) J DN (mm) Pressure 1emperature
m
3
Jhr kaw fiItrate 8ackwash bar C mm mm
VAZ 65 A5D
VAZ 80 A5D
VAZ !00 A5D
VAZ !25 A5D
'Nominal ow raIe aI 2 bar
1he above models are auIomaIically backwashed (pressure dierenIial), have sIainless sIeel hlIer housings and chrome nickel sIeel hlIers.
1ouch pad conIrollers wiIh Iwo line LLD displays.
for higher ow rate appIications consuIt your IocaI VeoIia Water 5oIutions & 1echnoIogies company, detaiIs beIow:
vsL cur wchsLc.
.e|iaae.cm
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC/Lcrkon//Q0023NV2.!
14
22
35
45
75
100
Rp 1
Rp 2
DN 65
DN 80
DN 100
DN 125
Rp 1
Rp 2
DN 65
DN 80
DN 100
DN 125
R
R
R 1
R 1
R
R
10
10
10
10
10
10
95
95
95
95
95
95
285
285
370
370
480
480
475
475
493
510
600
620
14
22
35
45
75
100
Rp 1
Rp 2
DN 65
DN 80
DN 100
DN 125
Rp 1
Rp 2
DN 65
DN 80
DN 100
DN 125
R
R
R 1
R 1
R
R
10
10
10
10
10
10
95
95
95
95
95
95
285
285
370
370
480
480
530
530
660
665
720
730
35
45
75
100
DN 65
DN 80
DN 100
DN 125
DN 65
DN 80
DN 100
DN 125
R 1
R 1
R
R
10
10
10
10
95
95
95
95
370
370
480
480
660
665
720
730
Granular Media Pressure Filtration
Granular media is contained within a pressure vessel, typically GRP or coated
steel. Water enters the top of the vessel and f o d e b e h t h g u o r h t s d r a w n w o d s w o
media, exiting through a collector system at the base. Contaminants are removed
by straining and/or adsorption depending on the chosen media. The lters must be
periodically backwashed.
Depending on the type of lter media used, granular media ltration has a variety of
applications including:
Filtration of water after chemical dosing to remove colloidal haze and turbidity
Pre-ltration to protect membrane processes from fouling
Filtration of cooling water to prevent heat exchanger fouling
Filtration of borehole water to remove iron and manganese
Removal of chlorine from water to protect ion exchange resins or membranes
Increasing the pH of acidic water to prevent corrosion
Feed water for drip irrigation systems
Sand is used to remove particulates and suspended solids. For high suspended solids
loads, a layer of coarse anthracite may be added above the sand. Multimedia ltration
may also be used for very ne ltration by adding a layer of ne garnet below the sand.

Sometimes two stages of ltration are used often anthracite and sand in the rst
vessel with sand and garnet in the second. This allows chemicals like polyelectrolytes
to be added between the stages to improve ltration e ciency.
Granular activated carbon is widely used to remove chlorine from water prior to ion
exchange or reverse osmosis where it could damage the resins or membranes.
Dechlorination by activated carbon also removes the taste associated with chlorine.
Activated carbon is also used to remove a wide range of organic chemicals including
chlorinated hydrocarbons, pesticides and the species that cause taste, odour and co-
lour.
Manganese dioxide is used as a catalytic lter bed to remove iron and manganese
from borehole water for a range of industrial applications.
Dolomite or limestone chips are occasionally used in a s a r o e n o l a r e h t i e , s r e t l
separate layer above sand, to neutralise low pH waters. The media slowly dissolves
and has to be replaced at regular intervals.
G
r
a
n
u
l
a
r

M
e
d
i
a
P
r
e
s
s
u
r
e
F
i
l
t
r
a
t
i
o
n
AcIicarbo"
AcIivaIed Carbon lilIers
AcIicarbo" acIivaIed carbon
hlIers remove chlorine Irom
drinking waIer.
llow raIes Irom 0.75 to 2.5 m
3
Jhr.
leaIures & 8enehIs
liberglass reinIorced plasIic
Iank wiIh gunmeIal valve block,
corrosion resisIanI
llexible connecIion hoses, simple
insIallaIion
8erkosorb" XS acIivaIed carbon
wiIh sand supporI layer, high
qualiIy media
Manual backwashing
OpIion Io connecI manomeIers
Io valve block Io moniIor pressure
dierenIial
ApplicaIions
Pre-IreaImenI Ior laboraIory,
healIh care and pharmaceuIical
waIer insIallaIions
DomesIic insIallaIions Ior removal
oI chlorine
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
Acticarbo"
quipment Performance & Dimensions
Ak 25
NominaI fIow kates m
3
5 . 2 2 1 5 7 . 0 r h /
Connections Inches
Width mm 620 620 620 620
Height mm 968 1439 1705 1748
Depth mm 480 480 530 550
Weight (Dperation) kg 55 75 150 200
Working Pressures bar 1.4 - 8.5
Max. Pressure bar 10 10 10 10
Max. 1emperature C
for higher ow rate appIications consuIt your IocaI VeoIia Water 5oIutions & 1echnoIogies company, detaiIs beIow.
vsL cur wchsLc.
www.veo|iawaterst.com
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC//ccarho//Q00!2NV!.!
Rp 1
40 40 40 40
Rp 1 Rp 1 Rp 1
1.4 - 8.5 1.4 - 8.5 1.4 - 8.5
Ak 45 Ak !05 Ak !30
Druck" Granular
Media Pressure
lilIers
M kange
Druck" granular media pressure
hlIers can remove suspended
solids, iron, manganese, hydrogen
sulhde, chlorine, phenol and
organics depending on Ihe chosen
media.
llow raIes Irom 0 to !0 m

hr.
leaIures & 8enehIs
SIeel vessels inIernally coaIed wiIh
epoxy, corrosion resisIanI
Service porI and deIachable cover,
easy access Ior mainIenance
Manual backwashing
Simplex and duplex conhguraIions,
exibiliIy
Dption
AuIomaIic air venI, Ior use
wiIh air in|ecIion sysIems
Righ QualiIy Media
8erkosan", suspended solids
removal
8erkodol", 8erkoliI" CA &
8erkospliI", deacidihcaIion,
CO2 reducIion
8erkoliI" lM & Mn, manganese,
iron and hydrogen sulhde removal
8erkosorb" XS, chlorine, phenol
and organics removal
ApplicaIions
PrevenI sIaining
Avoid corrosion wiIhin pipework,
heaI exchangers and boiler sysIems
kemove unpleasanI IasIes and
odors
Pre-IreaImenI Io ion exchange or
membrane sysIems
PosI IreaImenI Io chemical dosing
1exIiles
lood & beverage indusIry
lrrigaIion
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
Rydrex Chemicals
Rydrex 3000 and 6000 waIer
IreaImenI chemicals Irom veolia
WaIer SoluIions & 1echnologies
may opIionally be used Io enhance
hlIraIion.
Dck Can|a Media Pee Ii|e
quipment Performance
h t p e D t h g i e H h t d i W n o i t c e n n o C * s e t a k w o I f I e d o M
m r
3
]h k (inches) mm mm mm
5impIex
M 350 H 0.4 - I.5 I 470 I745 650
M 350 A 0.4 - I.5 I 470 I865 650
M 400 H 0.8 - I.8 I 570 I630 500
M 400 A 0.8 - I.8 I 570 I755 500
M 450 H 0 5 7 5 6 7 I 5 7 5 I 5 . 2 - 2 . I
M 450 A 0 5 7 5 8 8 I 5 7 5 I 5 . 2 - 2 . I
M 550 H I.7 - 3.5 I 680 2070 880
M 550 A I.7 - 3.5 I 680 2I90 880
M 650 H 2.5 - 5.0 I X 765 2I00 I0I5
M 650 A 2.5 - 5.0 I X 765 2220 I0I5
DupIex
M 350 H 0.8 - 3.0 I X I090 I745 650
M 350 A 0.8 - 3.0 I X I090 I945 650
M 400 H I.6 - 3.6 I II75 I630 500
M 400 A I.6 - 3.6 I II75 I765 500
M 450 H 2.4 - 5.0 I X I275 I765 750
M 450 A 2.4 - 5.0 I X I275 I965 750
M 550 H 3.5 - 7.0 I I490 2070 880
M 550 A 3.5 - 7.0 I I490 2I90 880
M 650 H 5.0 - I0.0 2 I695 2I00 I0I5
M 650 A 5.0 - I0.0 2 I695 2220 I0I5
' llow raIes are dependanI on Ieed waIer qualiIy and media selecIion.
AL. AuIomaIic air venIs RL. Manual air venIs
vsL cur wchsLc.
.e|iaae.cm
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC /ruck M angc//Q004!NV!.!
Dperation
Maximum operating pressure: 6 bar
Maximum operating temperature: 40C
Dptions
Choice oI high qualiIy media
Manual or auIomaIic air venIs
Air in|ecIion sysIem (compressor, in|ecIor, conIrol panel)
for higher ow rate appIications consuIt your IocaI VeoIia Water 5oIutions & 1echnoIogies company, detaiIs beIow.
MateriaI 5pecications
Pressure VesseIs Carbon SIeel. Lpoxy coaIed inside, primer coaIed ouIside.
Pipework Galvanised SIeel
NozzIes lood Grade Polypropylene
Druck" Granular
Media Pressure
lilIers
Kl kange
Druck" granular media pressure
hlIers can remove suspended
solids, iron, manganese, hydrogen
sulhde, chlorine, phenol and
organics depending on Ihe
chosen media.
llow raIes Irom 9 m

Jhr.
leaIures & 8enehIs
SIeel vessels inIernally coaIed wiIh
epoxy, corrosion resisIanI
1wo service porIs, easy access Ior
mainIenance
Simplex and duplex conhguraIions,
exibiliIy
8lower connecIion sockeI,
air]waIer backwashing
Dptions
AuIomaIic air venIs, Ior use wiIh
air in|ecIion sysIems
ConIrol panel, auIomaIic
backwashing
Righ QualiIy Media
8erkosan", suspended solids
removal
8erkodol", 8erkoliI" CA &
8erkospliI", deacidihcaIion,
CO2 reducIion
8erkoliI" lM & Mn, manganese,
iron and hydrogen sulhde removal
8erkosorb" XS, chlorine, phenol
and organics removal
ApplicaIions
PrevenI sIaining
Avoid corrosion wiIhin pipework,
heaI exchangers and boiler sysIems
kemove unpleasanI IasIes and
odours
Pre-IreaImenI Io ion exchange or
membrane sysIems
PosI IreaImenI Io chemical dosing
1exIiles
lood & beverage indusIry
lrrigaIion
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
Rydrex Chemicals
Rydrex 3000 and 6000 waIer
IreaImenI chemicals Irom veolia
WaIer SoluIions & 1echnologies
may opIionally be used Io enhance
hlIraIion.
Dck Can|a Media Pee Ii|e
quipment Performance
h t p e D t h g i e H h t d i W n o i t c e n n o C * s e t a k w o I f I e d o M
m
3
m m m m m m hr ]
5impIex
kf 800 x !500 4.2 - 7.5 DN 40 I8I5 2485 I425
kf 800 x 2000 5.0 - 8.0 DN 40 I8I5 2985 I425
kf !000 x 2000 8.0 - I2.0 DN 50 I855 3I03 I586
kf !200 x 2000 II.0 - I7.0 DN 65 2060 3I87 I835
kf !400 x 2500 I5.0 - 23.0 DN 80 2520 3795 2060
kf !600 x 2500 20.0 - 30.0 DN 80 2650 3986 2260
kf !800 x 2500 25.0 - 38.0 DN I00 3I45 4054 2620
kf 2000 x 2500 3I.0 - 47.0 DN I00 3308 4I79 2738
DupIex
kf 800 x !500 8.4 - I5.0 DN 50 2745 2485 I425
kf 800 x 2000 I0.0 - I6.0 DN 50 2745 2985 I425
kf !000 x 2000 I6.0 - 24.0 DN 65 2845 3I03 I586
kf !200 x 2000 22.0 - 34.0 DN 80 3235 3I87 I835
kf !400 x 2500 30.0 - 46.0 DN I00 3735 3795 2060
kf !600 x 2500 40.0 - 60.0 DN I00 4020 3986 2260
kf !800 x 2500 50.0 - 76.0 DN I25 4590 4054 2620
kf 2000 x 2500 62.0 - 94.0 DN I25 49I6 4I79 2738
' llow raIes are dependanI on Ieed waIer qualiIy and media selecIion.
MateriaI 5pecications
Pressure VesseIs Carbon SIeel. Lpoxy coaIed inside, primer coaIed ouIside.
Pipework PvC
NozzIes lood Grade Polypropylene
Dperation
Maximum operating pressure: 6 bar
Maximum operating temperature: 40C
A separaIely supplied blower package is required Ior Ihe backwash operaIion.
IectricaI suppIy
AuIomaIic models 230]400 v, 50 Rz
Dptions
Choice oI high qualiIy media
Manual or auIomaIic air venIs
Air in|ecIion sysIem (compressor, in|ecIor, conIrol panel)
8lower package
ConIrol panel Ior auIomaIic backwashing (based on Iime or pressure dierenIial)
for higher ow rate appIications consuIt your IocaI VeoIia Water 5oIutions & 1echnoIogies company, detaiIs beIow.
vsL cur wchsLc.
.e|iaae.cm
n kccpng wh hc progrcssvc naurc o hc conpany wc rcscrvc hc rgh o ancnd dcas whou nocc
VWS C/T/OC ruck angc/Q4NV
MulIimaI" l
MulIimedia lilIers
MulIimaI" l is a range oI
double and Iriple layer hlIers
Ior indusIrial and municipal
applicaIions.
llow raIes Ior sIandard sysIems
range Irom !.5 to 24.5 m
3
Jhr.
leaIures & 8enehIs
Double layer and Iriple layer hlIers
conIain anIhraciIe, sand and
garneI (Iriple), removal oI IurbidiIy
and suspended solids
Righ hlIraIion velociIy, reduced
pressure loss and increased Iime
beIween backwashes compared
Io single layer hlIers
CompacI PLC, simple operaIion
and moniIoring
PlasIic Iank, corrosion Iree,
lighIweighI, robusI
ApplicaIions
8orehole and surIace waIer
IreaImenI
lndusIrial process waIer
PreIreaImenI Io kO
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
Rydrex Chemicals
Rydrex 3000 and 6000 waIer
IreaImenI chemicals Irom veolia
WaIer SoluIions & 1echnologies
may opIionally be used Io enhance
hlIraIion.
vsL cur wchsLc.
veo|iawaterst.com
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC/Muna //Q004SNV2.!
Mu|timat" |
5ystem Performance
DoubIe Layer
h s a w k c a 8 s n o i t c e n n o C r e y a L e v i t c A w o I f
Min. Max. Nom.
Anthracite 5and
fIow 1ime
0.8x0.2 0.6x0.8
m
3
Jhr m
3
Jhr m
3
Jhr mm mm inches m
3
Jhr mins
fPA8-20 I.5 3.2 2.I 500 200 I 5 I0-I5
fPA8-24 I.9 4.2 2.8 500 200 I 7 I0-I5
fPA8-30 3.I 6.6 4.4 500 200 1 II I0-I5
fPA8-36 4.4 9.5 6.3 500 200 2 I6 I0-I5
fPA8-48 8.6 I8.4 I2.3 500 200 2 3I I0-I5
1ripIe Layer
h s a w k c a 8 s n o i t c e n n o C r e y a L e v i t c A w o I f
Min. Max. Nom.
Anthracite 5and Carnet Carnet
fIow 1ime
0.8x0.2 0.6x0.8 (0.3x0.6) (!.4x2.3)
m
3
Jhr m
3
Jhr m
3
Jhr mm mm mm mm inches m
3
Jhr mins
fPA1-20 2.I 4.3 3.2 400 I90 80 I50 1 7 I3-I5
fPA1-24 2.8 5.6 4.2 400 I90 80 I50 1 I0 I3-I5
fPA1-30 4.4 8.7 6.6 400 I90 80 I50 1 I5 I3-I5
fPA1-36 6.3 I2.6 9.5 400 I90 80 I50 2 22 I3-I5
fPA1-48 I2.3 24.5 I8.4 400 I90 80 I50 2 43 I3-I5
5ystem Dimensions
I e s s e V m e t s y 5 I e d o M
Width Depth Height Weight Diameter Height
fPA8 & fPA1 mm mm
20 800 650 1914 70 522 1666
24 900 750 2140 90 595 1892
30 1050 900 2140 135 746 1892
36 1200 1150 2140 190 896 1892
48 1550 1400 2302 320 1250 2005
MateriaI 5pecications
1 A P f & 8 A P f I e d o M
Piping uPvC (Iood grade)
VesseI Polyamide
Dperation
Maximum Dperating Pressure: 6 bar
Maximum Dperating 1emperature: 40C
IectricaI 5uppIy
220v, 50Rz
for higher ow rate appIications consuIt your IocaI VeoIia Water 5oIutions & 1echnoIogies company, detaiIs beIow.
mm mm mm kg
MulIimaI" ll
MulIimedia lilIers
MulIimaI" ll is a range oI double
layer, Iriple layer and acIivaIed
carbon hlIers Ior indusIrial and
municipal applicaIions.
llow raIes Ior sIandard sysIems
range Irom 9 to !4! m
3
Jhr.
leaIures & 8enehIs
Double layer and Iriple layer hlIers
conIain anIhraciIe, sand and
garneI (Iriple), removal oI IurbidiIy
and suspended solids
AcIivaIed carbon hlIers, removal
oI odors, IasIes and chlorine, and
arsenic reducIion
Righ hlIraIion velociIy, reduced
pressure loss and increased Iime
beIween backwashes compared
Io single layer hlIers
CompacI PLC, simple operaIion
and moniIoring, economic design
Lpoxy coaIed carbon sIeel Iank,
corrosion resisIanI
ApplicaIions
8orehole and surIace waIer
IreaImenI
lndusIrial process waIer
PreIreaImenI Io kO
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
Rydrex Chemicals
Rydrex 3000 and 6000 waIer
IreaImenI chemicals Irom veolia
WaIer SoluIions & 1echnologies
may opIionally be used Io enhance
hlIraIion.
vsL cur wchsLc.
www.veo|iawaterst.com
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC/Muna //Q004NV2.!
Mu|timat" ||
5ystem Performance
DoubIe Layer
h s a w k c a 8 s n o i t c e n n o C r e y a L e v i t c A w o I f
Min. Max. Nom.
Anthracite 5and
fIow 1ime
0.8x0.2 0.6x0.8
m
3
Jhr m
3
Jhr m
3
Jhr mm mm inches m
3
Jhr min
Jhr
Jhr
fI8-!25 8.6 I8.4 I2.3 500 200 2 30.7 I0-I5
fI8-!50 I2.4 26.5 I7.7 500 200 3 44.2 I0-I5
fI8-!80 I7.8 38.2 25.4 500 200 4 63.6 I0-I5
fI8-2!0 24.2 52 34.6 500 200 4 86.6 I0-I5
fI8-225 27.8 59.6 39.8 500 200 6 99.4 I0-I5
fI8-250 34.4 73.6 49.I 500 200 6 I22.7 I0-I5
fI8-300 49.5 I06 70.7 500 200 6 I76.7 I0-I5
1ripIe Layer
h s a w k c a 8 s n o i t c e n n o C r e y a L e v i t c A w o I f
Min. Max.
Nom.
5and Carnet Carnet
fIow 1ime
0.8x0.2 0.6x0.8 (0.3x0.6) (!.4x2.3)
m
3
Jhr m
3
Jhr m
3
Jhr mm mm mm mm inches m
3
fI1-!25 I2.3 24.5 I8.4 400 I90 80 I50 2 43 I3-I5
fI1-!50 I7.7 35.3 26.5 400 I90 80 I50 3 6I.9 I3-I5
fI1-!80 25.4 50.9 38.2 400 I90 80 I50 4 89.I I3-I5
fI1-2!0 34.6 69.3 52 400 I90 80 I50 4 I2I.2 I3-I5
fI1-225 39.8 79.5 59.6 400 I90 80 I50 6 I39.2 I3-I5
fI1-250 49.I 98.2 73.6 400 I90 80 I50 6 I7I.8 I3-I5
fI1-300 70.7 I4I.4 I06 400 I90 80 I50 6 247.4 I3-I5
Activated
e s n i k h s a w k c a 8 s n o i t c e n n o C r e y a L e v i t c A w o I f
CIeaning
Carbon
Min. Max. Nom. 5iIex
Activated
fIow fIow
1ime
Carbon
m
3
Jhr m
3
Jhr m
3
Jhr kg mm inches m
3
Jhr m
3
fIC-!25 I2.3 24.5 I8.4 400 I250 2 22.7 I8 I5
fIC-!50 I7.7 35.3 26.5 700 I250 3 32.7 26 I5
fIC-!80 25.4 50.9 38.2 II50 I250 4 45.4 38 I5
fIC-2!0 34.6 69.3 52 I850 I250 4 59 52 I5
fIC-225 39.8 79.5 59.6 2250 I250 6 79.5 59 I5
fIC-250 49.I 98.2 73.6 3025 I250 6 90.8 73 I5
fIC-300
fPC-20
fPC-24
fPC-30
fPC-36
fPC-42
fPC-48
3.0
4.6
5.8
I0.4
I4.9
I7.9
25
50
75
I75
300
375
I25
200
250
425
625
750
25
25
40
40
50
65
625
I000
I300
I750
2I00
2750
4250
625
I000
I300
I750
2I00
2750
4250
800
900
I050
I300
I400
I550
650
750
900
II50
I250
I400
2468
2523
2588
2748
2657
2697
2I0
340
445
820
I275
I525
520
640
720
960
II60
I260
2220
2275
2340
2500
2360
2400
I250
I500
I800
2I00
2250
2500
3000
I250
I500
I800
2I00
2250
2500
3000
I980
2040
2300
2320
2520
26I0
28I0
3620
3780
4040
4I20
4320
45I0
4830
3.6
5.47
9.96
I2.43
I7.92
2I.52
3.0
4.6
5.8
I0.4
I4.9
I7.9
I5
I5
I5
I5
I5
I5
70.7 I4I.4 I06 5I25 I250 6 I27.I I06 I5
5ystem Dimensions
I e s s e V m e t s y 5 I e d o M
Width Depth Height Weight Diameter Height
m m m m g k m m m m m m 1 I f & 8 I f
!25 1900 1450 2300
!50 2250 1700 2410
!80 2500 2000 2670
2!0 2800 2300 2720
225 3000 2450 2920
250 3300 2700 3060
300 3900 3200 3320
fIC
!25 1900 1450 3300
!50 2250 1700 3410
!80 2500 2000 3670
2!0 2800 2300 3720
225 3000 2450 3920
250 3300 2700 4060
300
fPC
20
24
30
36
42
48
3900 3200 4320
MateriaI 5pecications
ModeI fI8, fI1 & fIC
Piping uPvC (Iood grade) or sIainless
VesseI Lpoxy coaIed carbon sIeel
IectricaI 5uppIy
220v, 50Rz
Dperation
Maximum Dperating Pressure 6 bar
Maximum Dperating 1emperature 40C
for higher ow rate appIications consuIt your IocaI VeoIia Water
5oIutions & 1echnoIogies company, detaiIs beIow.
min
min
Anthracite
MulIimaI" Duo
Double lilIraIion in Series
MulIimaI" Duo combines double
layer and Iriple layer MulIimaI"
hlIers wiIh a chemical IreaImenI
Io produce high qualiIy waIer.
PlasIic vessels. 2.! to 24.5 m
3
Jhr.
Carbon sIeel vessels.
!2.3 to !4!.4 m
3
Jhr.
leaIures & 8enehIs
Double layer and Iriple layer hlIers
conIain anIhraciIe, sand and
garneI (Iriple), removal oI IurbidiIy
and suspended solids
Righ hlIraIion velociIy, reduced
pressure loss and increased Iime
beIween backwashes compared
Io single layer hlIers
CompacI PLC, simple operaIion
and moniIoring
PlasIic or epoxy coaIed sIeel Ianks,
durable, robusI
ApplicaIions
8orehole and surIace waIer
IreaImenI
lndusIrial process waIer
PreIreaImenI Io kO
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
Rydrex Chemicals
Rydrex 3000 and 6000 waIer
IreaImenI chemicals Irom veolia
WaIer SoluIions & 1echnologies
may opIionally be used Io enhance
hlIraIion.
vsL cur wchsLc.
www.veo|iawaterst.com
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS TOC/Muna O/Q000NV2.!
Dperation
Maximum Dperating Pressure: 6 bar
Maximum Dperating 1emperature: 40C
for higher ow rate appIications consuIt your IocaI
VeoIia Water 5oIutions & 1echnoIogies company,
detaiIs beIow.
Mu|timat" uo
5ystem Performance
ModeIs
h s a w k c a 8 s n o i t c e n n o C w o I f
Min. Max. Nom. VesseI ! VesseI 2 fIow 1ime
m
3
Jhr m
3
Jhr m
3
Jhr inches inches m
3
Jhr mins
fPA8-20 + fPA1-20 2.I 4.3 3.2 I I 5 I0-I5
fPA8-24 + f8A1-24 2.8 5.6 4.2 I I 7 I0-I5
fPA8-30 + f8A1-30 4.4 8.7 6.6 I I II I0-I5
fPA8-36 + f8A1-36 6.3 I2.6 9.5 2 2 I6 I0-I5
fPA8-48 + f8A1-48 I2.3 24.5 I8.4 2 2 3I I0-I5
fI8-!25 + fI1-!25 I2.3 24.3 I8.4 2 2 30.7 I0-I5
fI8-!50 + fI1-!50 I7.7 35.3 26.5 3 3 44.2 I0-I5
fI8-!80 + fI1-!80 25.4 50.9 38.2 4 4 63.6 I0-I5
fI8-2!0 + fI1-2!0 34.6 69.3 52 4 4 86.6 I0-I5
fI8-225 + fI1-225 39.8 79.5 59.6 6 6 99.4 I0-I5
fI8-250 + fI1-250 49.I 98.2 73.6 6 6 I22.7 I0-I5
fI8-300 + fI1-300 70.7 I4I.4 I06 6 6 I76.7 I0-I5
Active Layer
ModeIs
t e n r a C t e n r a C d n a 5 e t i c a r h t n A
) 3 . 2 x 4 . ! ( ) 6 . 0 x 3 . 0 ( 8 . 0 x 6 . 0 2 . 0 x 8 . 0
m m m m m m m m
fPA8 0 0 2 0 0 5
fI8 0 0 2 0 0 5
fPA1 0 5 I 0 8 0 9 I 0 0 4
fI1 0 5 I 0 8
70
90
I35
I90
320
625
I000
I300
I750
2I00
2750
4250
522
595
746
896
I250
I250
I500
I800
2I00
2250
2500
3000
I666
I892
I892
I892
2005
I980
2040
2300
2320
2520
26I0
28I0
0 9 I 0 0 4
5ystem Dimensions
I e s s e V m e t s y 5 I e d o M
Width Depth Height Weight Diameter Height
fPA8 & fPA1 mm mm mm kg mm mm
20 800 650 1914
24 900 750 2140
30 1050 900 2140
36 1300 1150 2140
48 1550 1400 2302
fI8 & fI1
!25 1900 1450 2300
!50 2250 1700 2410
!80 2500 2000 2670
2!0 2800 2300 2720
225 3000 2450 2890
250 3300 2700 3060
300 3900 3200 3320
MateriaI 5pecications
ModeI fPA8 & fPA1 fI8 & fI1
Piping uPvC (Iood grade) uPvC (Iood grade) or sIainless
VesseI Polyamide Lpoxy coaIed carbon sIeel
IectricaI 5uppIy
220v, 50Rz
Softening
Salts of calcium and magnesium have low solubility. In water they are collectively
called hardness and cause a variety of problems in industrial water use, including:
Scale in cooling towers, causing blockages
Scale in low pressure steam boilers, reducing heat transfer e ciency
Fouling in reverse osmosis systems, causing loss of performance
Scale in hot water caloriers (heaters), reducing heat transfer e ciency
Scum in laundries, reducing e ciency of detergents
Deposits in domestic hot and cold water services, contributing to Legionella
problems
Streaky deposits in glass and bottle washing
Ion exchange softening is the most widely used softening process. Water is passed
through a bed of cation exchange resin where calcium and magnesium ions are
removed from the water in exchange for sodium ions. When the sodium ions on
the resin have been replaced by calcium or magnesium ions, the softening reaction
stops and the resin need to be regenerated. Regeneration is achieved by passing a
salt solution through the resin bed.
Softening
S
o
f
t
e
n
i
n
g
Berkoion Softeners
Compact Range
Berkoion Compact softeners
provide high quality softened
water for industrial and domestic
applications.
Flow rates from 1.0 to 2.3 m
3
/hr.
Features & Benets:
Compact designs with integrated
brine tanks; space saving, easy
installation
Simplex configuration
Volume or time based automatic
regeneration; minimal operator
involvement
Optimised hydraulic conditions;
reduce salt usage, low cost per litre
of treated water
A-Series
Automatically regenerated after
4 days without use; bacterial
control, avoids resin problems
Complete disinfection during
regeneration; bacterial control
Electronic display; simple
monitoring and operation
Applications
Boiler feed
RO feed water
General manufacturing
Glass washing
Cleaning and rinse waters
Dishwashing
Domestic
Related Services
Local after-sales service and
support teams oer preventative
and corrective maintenance
programs to ensure the long-term,
ecient operation of installed
plant.
Visit our website:
www.veoliawaterst.com
Model Flow
Rates*
Capacity Salt Usage
Per Regen.
Connection Working
Pressures
Width Height Depth
m
3
/hr kg CaCO
3
kg inches bar mm mm mm
Z Series
Simplex, time controlled
Z15 KV 1.0 - 1.2 1.1 3.75 R 1 1.4 - 8.5 570 1090 435
A Series
Simplex, volume controlled
A4 KV 1.9 - 2.1 0.18 0.36 Rp 1 1.4 - 8.0 500 665 320
A13 KV 2.0 - 2.3 0.64 1.17 Rp 1 1.4 - 8.0 590 1090 280
*A Series - With pressure loss of 0.8 bar and mixing from 20 to 8dH (358 to 143 ppm CaCO
3
)
Z15 KV - With pressure loss of 0.32 bar at 1.2 m
3
/h
System Performance
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkoion Compact Range/AQF0013_EN_V2.0-Nov.13
Resin Vessels Glass Reinforced Plastic (GRP)
Brine Tanks Polyethylene (PE)
Material Specications
Potable water free from organic contamination and suspended matter. Maximum temperature 30C (40C for Z15 KV).
Feed Water Requirements
All models 230V 50Hz standard
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Electrical Supply
Berkoion Softeners
8erkoion
1M
SoIIeners
Classic Simplex kange
8erkoion
1M
Classic Simplex
soIIeners provide high qualiIy
soIIened waIer Ior indusIrial
applicaIions.
llow raIes Irom ! to !7 m
3
Jr.
leaIures & 8enehIs
Proven designs and maIerials,
emcienI operaIion, easy Io
mainIain, reliable
volume or Iime conIrolled,
auIomaIic or semi-auIomaIic
regeneraIion, minimal operaIor
involvemenI
5pcc modIs
8ercore" counIer currenI regenera-
Iion, reduces salI usage and wasIe,
improves IreaIed waIer qualiIy
Advanced conIroller wiIh LCD
display, range oI conIrol opIions,
easy Io use, inIegraIes wiIh
cenIralised conIrol sysIems
ApplicaIions
8oiler Ieed
Glass washing
Cleaning and rinse waIers
kO Ieed waIer
General manuIacIuring
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
8erkoion
1M
Softeners
5ystem Performance
h t p e D t h g i e H h t d i W g n i k r o W n o i t c e n n o C e g a s U t I a 5 y t i c a p a C s e t a k w o I f I e d o M
s e r u s s e r P . n e g e k r e P
m r
3
]h kg CaCO3 kg kp (inches)]DN(mm) bar mm mm mm
1ime controIIed, semi automatic
H2 I.0 - I.3 I.4 5.0 kp 2.0 - 8.5 725 995 390
H3 I.5 - 2.0 2.I 7.5 kp 2.0 - 8.5 9I0 I00I 530
H5 2.5 - 3.0 3.6 I2.5 kp 2.0 - 8.5 9I0 I472 530
ZH25 I.4 - 2.0 I.8 6.25 kp I I.4 - 8.5 750 II20 390
ZH5 2.5 - 3.0 3.6 I2.5 kp I I.4 - 8.5 935 I450 530
1ime controIIed, automatic, CC
AZ25 I.4 - 2.0 I.3 2.3 kp I I.8 - 8.5 768 II20 390
AZ45 2.3 - 3.2 2.3 4.I kp I 2.0 - 8.5 935 I590 530
AZ7 2.8 - 3.5 3.5 6.3 kp I 2.0 - 8.5 976 I596 530
AZ9 4.0 - 5.0 4.5 8.I kp I 2.5 - 8.5 I055 I867 600
AZ!5 6.0 - 7.2 4.8 8.55 DN 40 2.0 - 8.5 II98 I9I8 600
AZ!5 8.0 - I0.0 7.I I2.6 DN 40 2.5 - 8.5 I570 I928 930
AZ25 I2.0 - I4.0 I2.2 2I.6 DN 50 2.5 - 8.5 I702 I895 930
AZ35 I5.0 - I7.0 I7.3 30.6 DN 50 2.5 - 8.5 I973 2228 II20
VoIume controIIed, automatic, CC
AWA25 I.4 - 2.0 I.3 2.5 kp I I.8 - 8.5 768 II4I 390
AWA45 2.3 - 3.2 2.3 4.0
AWA7 2.8 - 3.5 3.5 6.5 kp I 2.0 - 8.5 976
AWA9 kp I 2.5 - 8.5 I080
AW!5 6.0 - 7.2 4.8 8.6 DN 40 2.0 - 8.5 II98 I9I8 600
AW!5 8.0 - I0.0 7.I I2.6 DN 40 2.5 - 8.5 I570 I928 930
AW25 I2.0 - I4.0 I2.2 2I.6 DN 50 2.5 - 8.5 I702 I895 930
AW35 I5.0 - I7.0 I7.3 30.6 DN 50 2.5 - 8.5 I973 2228 II20
CC = 8ercore" counIer currenI regeneraIion
DispIays & ControIIers
Iectronic ControIIer AZ Series
Microprocessor ControIIer with LD DispIay AW25, AW45, AW70, AW90
AW!5, AW!5, AW25, AW35
Advanced microprocessor conIroller wiIh LCD display. lnIuiIive symbol based keypad, programmable wiIh reIenIive memory, indicaIion oI currenI ow raIe,
capaciIy remaining beIore nexI regeneraIion, pulse inpuI. May be connecIed Io cenIralised conIrol sysIem.
MateriaI 5pecications
kesin VesseIs Glass keinIorced PlasIic (GkP)
8rine 1anks PolyeIhylene (PL)
feed Water 5uppIy DuaIity
PoIable waIer Iree Irom organic conIaminaIion and suspended maIIer. Maximum IemperaIure 30C (65C Ior ZR25 and ZR50).
IectricaI 5uppIy
230v 50Rz sIandard (no supply necessary Ior R20, R30 and R50)
for higher ow rate appIications consuIt your IocaI VeoIia Water 5oIutions & 1echnoIogies company, detaiIs beIow.
vsL cur wchsLc.
www.veo|iawaterst.com
n kccpng wh hc progrcssvc naurc o hc conpan, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC/Lcrkoon Cassc Snpc angc//Q00!NV2.!
kp I 2.0 - 8.5 935 I620
I6II
I886 600
530
530
4.0 - 5.0 4.5 8.0
Berkoion Softeners
Classic Duplex Range
Berkoion Classic Duplex
softeners provide high quality
softened water for industrial
applications.
Flow rates from 1.4 to 17 m
3
/hr.
Features & Benets:
Proven designs and materials;
efficient operation, easy to
maintain, reliable
Volume controlled automatic
regeneration; minimal operator
involvement, efficient operation
Bercore counter current
regeneration; reduces salt usage
and waste, lowers cost per litre of
treated water, improves treated
water quality
Duplex design; continual flow of
treated water
Specic models
Advanced controller with LCD
display; range of control options,
easy to use, integrates with
centralized control systems
Applications
Boiler feed
Glass washing
Cleaning and rinse waters
RO feed water
General manufacturing
Related Services
Local after-sales service and
support teams offer preventative
and corrective maintenance
programs to ensure the long-term,
efficient operation of installed
plant.
Visit our website:
www.veoliawaterst.com
Model Flow Rates Capacity Salt Usage
Per Regen.
Connection Working
Pressures
Width Height Depth
m
3
/hr kg CaCO
3
kg Rp (inches)/DN(mm) bar mm mm mm
Volume controlled
AWA 2-25 1.4 - 2.0 1.3 2.5 Rp 1 1.8 - 8.5 1110 1087 390
AWA 2-45 2.3 - 3.2 2.3 4.0 Rp 1 2.0 - 8.5 1310 1577 530
AWA 2-70 2.8 - 3.5 3.5 6.5 Rp 1 2.0 - 8.5 1447 1556 530
AWA 2-90 4.0 - 5.0 4.5 8.0 Rp 1 2.0 - 8.5 1579 1832 600
AW 2-105 6.0 - 7.2 4.8 8.6 DN 40 2.0 - 8.5 1748 1918 650
AW 2-150 8.0 - 10.0 7.1 12.6 DN 40 2.5 - 8.5 2190 1928 980
AW 2-250 12.0 - 14.0 12.2 21.6 DN 50 2.5 - 8.5 2482 1895 995
AW 2-350 15.0 - 17.0 17.3 30.6 DN 50 2.5 - 8.5 2853 2228 1185
Displays & Controllers
AW 2-25, AW 2-45, AW 2-70, AW 2-90
Microprocessor controller with LED display.
AW105, AW150, AW250, AW350
Advanced microprocessor controller with LCD display. Intuitive symbol based keypad; programmable with retentive memory; indication of current
ow rate, capacity remaining before next regeneration; pulse input. May be connected to centralized control system.
System Performance
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkoion Classic Duplex Range/AQF0040_EN_V3.0-Nov.13
Resin Vessels Glass Reinforced Plastic (GRP)
Brine Tanks Polyethylene (PE)
Material Specications
Potable water free from organic contamination and suspended matter. Maximum temperature 40C.
Feed Water Requirements
All models 230V 50Hz standard
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Electrical Supply
Berkoion Softeners
Berkoion Softeners
High Flow Duplex Range
Berkoion High Flow Duplex
softeners provide high quality
softened water for industrial
applications.
Flow rates from 2.7 to 68 m
3
/hr.
Features & Benets:
Proven designs and materials;
efficient operation, easy to
maintain, reliable
Volume controlled automatic
regeneration; minimal operator
involvement, efficient operation
Bercore counter current
regeneration; reduces salt usage
and waste, lowers cost per litre of
treated water, improves treated
water quality
Duplex design; continual flow of
treated water
Multiple individual valves; reduce
pressure loss by almost 50%
compared to single valve systems
Advanced controller with LCD
display; range of control options,
intuitive operation, integrates with
centralized control systems
Applications
Boiler feed
Glass washing
Cleaning and rinse waters
RO feed water
General manufacturing
Related Services
Local after-sales service and
support teams offer preventative
and corrective maintenance
programs to ensure the long-term,
efficient operation of installed
plant.
Visit our website:
www.veoliawaterst.com
Model Flow Rates Capacity Salt Usage
Per Regen.
Connection Working
Pressures
Width Height Depth
m
3
/hr kg CaCO
3
kg mm bar mm mm mm
Volume controlled
AW 2-550 2.7 - 27.0 28.0 49.5 DN 80/80 3.0 - 8.5 3195 2650 1390
AW 2-800 3.9 - 39.0 40.7 72.0 DN 100/80 3.0 - 8.5 3945 2735 1695
AW 2-1050 5.1 - 51.0 53.4 94.5 DN 100/80 3.0 - 8.5 4490 2815 1770
AW 2-1400 6.8 - 68.0 71.2 126.0 DN 100/100 3.0 - 8.5 4665 2910 1925
Displays & Controllers
AW Series
Advanced microprocessor controller with LCD display. Intuitive symbol based keypad; programmable with retentive memory; indication of current
ow rate, capacity remaining before next regeneration; pulse input. May be connected to centralized control system.
*All models require a source of compressed air
System Performance
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkoion High Flow Duplex Range/AQF0043_EN_V2.0-Nov.13
Resin Vessels Glass Reinforced Plastic (GRP)
Brine Tanks Polyethylene (PE)
Pipework Polyvinyl Chloride (PVC)
Material Specications
Potable water free from organic contamination and suspended matter. Maximum temperature 40C.
Feed Water Requirements
All models 230V 50Hz standard
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Electrical Supply
Berkoion Softeners
Reverse Osmosis
Reverse osmosis (RO) is a process that uses a membrane to remove over 95% of
dissolved salts, such as calcium bicarbonate and sodium chloride, from water. It is
used either alone or in combination with processes such as ion exchange in a variety
of industrial applications where the total dissolved solids (TDS) concentration in
water has to be reduced, including:
Puried water for pharmaceutical manufacturing
Laboratory glassware washing
Semiconductor rinse water
Process water
Water for soft drinks production and brewing
Boiler feed water
Desalination of brackish or sea water to drinking water quality
Recycling and reuse
The RO membrane also acts as a very ne lter removing 99% of suspended and
colloidal solids, bacteria and organic molecules with molecular weights in excess of
about 200Da. This makes the process particularly attractive for applications where
treated water not only has to be low in TDS but also of high clarity and free from
bacteria, such as that used for soft drinks and pharmaceuticals manufacturing.
Reverse Osmmossis
R
e
v
e
r
s
e
O
s
m
o
s
i
s
SIRION Mini
TM
Reverse Osmosis Systems
SIRION Mini
TM
reverse osmosis
systems produce high purity
water, removing up to 98% of
dissolved inorganics and over
99% of large dissolved organics,
colloids and particles.
Flow rates from 10 to 90 l/hr.
Features & Benets
Low energy membranes result in
lower operating pressures; cost
savings
Optimized ow:size ratio; space
saving and ecient
5m pre-ltration included within
unit; membrane protection
Digital user interface; simple
operation, monitoring of
conductivity and temperature
Dry run monitor; pump protection
Treated water diverted at start-up;
ensures water quality
Timed recirculation rinse; reduces
membrane fouling
Option
Output to PLC via analogue signal
for conductivity monitoring
Applications
Micro Electronics
Boiler feed
Hospitals
Food and beverage industry
Automotive industry
Laboratory
Industrial process water
Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION Mini/AQF0010_EN_V3.0
SIRION Mini
TM
System Performance
Model 10-15 EP 10-40 EP 10-80 EP
Nominal Flows at 12C*
Permeate 0 9 - 0 6 5 4 - 0 3 0 2 - 0 1 r h / l
Feed 0 7 1 0 9 0 4 r h / l
Typical Salt Rejection 8 9 - 6 9 8 9 - 6 9 8 9 - 6 9 %
Pump Motor Size 5 2 . 0 5 2 . 0 5 2 . 0 W k
*Flow rates are dependent on feed water quality, those quoted are typical values based on 1000 ppm TDS & SDI <3.
System Dimensions
Model 10-15 EP 10-40 EP 10-80 EP
Height 7 9 6 7 9 6 7 9 6 m m
Depth 0 8 3 0 8 3 0 8 3 m m
Width 0 5 4 0 5 4 0 5 4 m m
Weight 3 6 0 6 53 g k
Pipe Connections
Model
Feed Water (BSPP Male) 1/2''
m m 8 m m 8 m m 8
m m 8 m m 8 m m 8
' ' 2 / 1 ' ' 2 / 1
Permeate (push in)
Concentrate (push in)
Feed Water Supply Quality
Potable water free from organic contamination, chlorine and suspended matter. Softening may be required for hard water areas.
Supply Pressure r a b 6 . x a m r a b 2 . n i m
Temperature C 5 2 . x a m C 2 . n i m
Electrical Supply
All models 230V 50Hz standard.
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
10-15 EP 10-40 EP 10-80 EP
SIRION

Midi
Reverse Osmosis Systems
SIRION Midi reverse osmosis
systems produce high purity
water, removing up to 98% of
dissolved inorganics and over
99% of large dissolved organics,
colloids and particles.
Flow rates from 90 to
800 l/hr.
Features & Benets
Low energy membranes result
in lower operating pressures;
cost savings
Optimised ow:size ratio; space
saving and ecient
1m pre-ltration included within
the unit; membrane protection
Programmable user interface;
simple operation, monitoring and
storage (14 days) of ow rate,
conductivity and temperature
values
Modem & RS232 connections
Dry run monitor; pump protection
Treated water diverted at start-up;
ensures water quality
Timed recirculation rinse; reduces
membrane fouling
Option
Output to PLC via analogue signal
for conductivity monitoring
Applications
Boiler feed
Industrial process water
Cleaning and rinse waters
Healthcare
Pharmaceuticals
Laboratory
Reuse/recycling
Related Services
Local after-sales service and
support teams oer preventative
and corrective maintenance
programs to ensure the long-term,
ecient operation of installed plant.
Hydrex Chemicals
Hydrex 4000 water treatment
chemicals from Veolia Water
Solutions & Technologies should
be used for optimized operation.
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION Midi/AQF0009_EN_V3.1 - Dec.13
SIRION

Midi
System Performance
Model
Nominal Flows at 12C*
Permeate
Feed
Typical Salt Rejection
Pump Motor Size
*Flow rates are dependent on feed water quality, those quoted are typical values based on 1000 ppm TDS & SDI <3.
System Dimensions
Model
Height mm
Depth mm
mm
kg
Width
Weight
Feed Water Supply Quality
Potable water free from organic contamination, chlorine and suspended matter. A softened water supply is normally required.
Supply Pressure
Temperature
Electrical Supply
10-100EP to 10-300EP models 230V, 1ph, 50 Hz standard
10-500EP & 10-750 EP models 400V, 3phNPE, 50 Hz standard
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Pipe Connections
Model
Feed Water (push in)
Permeate (push in)
First Permeate (push in)
Concentrate (push in)
1010
620
600
59
10-100 EP
12 mm
12 mm
12 mm
12 mm
10-100 EP
90-110
150
96-98
0.56
10-100 EP
l/hr
l/hr
%
kW
1260
620
600
61
10-200 EP
12 mm
12 mm
12 mm
12 mm
10-200 EP
10-200 EP
180-220
300
96-98
0.56
1260
620
600
68
10-300 EP
12 mm
12 mm
12 mm
12 mm
10-300 EP
10-300 EP
280-330
450
96-98
0.56
1260
620
600
73
10-500 EP
15 mm
15 mm
15 mm
12 mm
10-500 EP
10-500 EP
450-550
750
96-98
1.5
1260
620
600
95
10-750 EP
15 mm
15 mm
15 mm
12 mm
10-750 EP
10-750 EP
650-800
1000
96-98
1.5
r a b 6 . x a m
C 5 2 . x a m
r a b 2 . n i m
C 2 . n i m
SIRION

Maxi
Reverse Osmosis Systems
SIRION Maxi reverse osmosis
systems produce high purity
water, removing up to 98% of
dissolved inorganics and over
99% of large dissolved organics,
colloids and particles.
Flow rates from 450 to
5000 l/hr.
Features & Benets
Low energy membranes result
in lower operating pressures;
cost savings
Optimised ow:size ratio; space
saving and ecient
1m pre-ltration included within
the unit; membrane protection
Programmable user interface;
simple operation, monitoring and
storage (14 days) of ow rate,
conductivity and temperature
values
Modem & RS232 connections
Dry run monitor; pump protection
Treated water diverted at start-up;
ensures water quality
Timed recirculation rinse; reduces
membrane fouling
Option
Output to PLC via analogue signal
for conductivity monitoring
Applications
Boiler feed
Industrial process water
Cleaning and rinse waters
Reuse/recycling
Healthcare
Pharmaceuticals
Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Hydrex Chemicals
Hydrex 4000 water treatment
chemicals from Veolia Water
Solutions & Technologies should
be used for optimised operation.
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION Maxi/AQF0007_EN_V3.1 - Dec.13
System Performance
Model 14-500-EP 14-750-EP 14-1000-EP 14-1500-EP 14-2000-EP 14-2500-EP 14-3000-EP 14-4000-EP 14-5000-EP
Nominal Flows at 12C*
Permeate
Feed
Typical Salt Rejection %
Pump Motor Size
*Flow rates are dependent on feed water quality, those quoted are typical values based on 1000 ppm TDS & SDI <3.
System Dimensions
Model 14-500-EP 14-750-EP 14-1000-EP 14-1500-EP 14-2000-EP 14-2500-EP 14-3000-EP 14-4000-EP* 14-5000-EP*
Height
Depth mm
Width mm
Weight kg
*If height is an issue consider the SIRION Mega
Feed Water Supply Quality
Potable water free from organic contamination, chlorine and suspended matter. A softened water supply is normally required.
Supply Pressure r a b 6 . x a m r a b 2 . n i m
Temperature C 5 2 . x a m C 2 . n i m
Electrical Supply
All models 380/415V, 3 phase, 50Hz standard.
All connections are union socket - PVC-U
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Pipe Connections
Model 14-500-EP
Feed DN 20
DN 15
DN 15
DN 15
14-750-EP
DN 20
DN 15
DN 15
DN 15
14-1000-EP
DN 20
DN 15
DN 15
DN 15
14-1500-EP
DN 25
DN 15
DN 25
DN 25
DN 25
DN 15
DN 25
DN 25
14-2000-EP 14-2500-EP
DN 32
DN 25
DN 25
DN 25
DN 32
DN 25
DN 25
DN 25
14-3000-EP 14-4000-EP
DN 40
DN 25
DN 32
DN 32
14-5000-EP
DN 40
DN 25
DN 32
DN 32
Permeate
First Permeate
Concentrate
2358
1070
636
290
1630
1070
636
240
2358
330
636
1070
2358
370
636
1145
2358
410
636
1070
2950
300
800
1200
2950
325
800
1200 1070
636
220
1630
1070
636
200
1630 mm
l/hr
l/hr
kW
96-98
450-500
700
2.2
96-98
650-800
1000
2.2
96-98
950-1100
1400
2.2
96-98
1450-1600
2000
4.0
96-98
1950-2100
2700
4.0
96-98
2450-2600
3300
4.0
96-98
2900-3100
4000
4.0
96-98
3800-4000
5200
4.0
96-98
4700-5000
6250
5.5
SIRION

Maxi
SIRION

Mega
Reverse Osmosis Systems
SIRION Mega reverse osmosis
systems produce high purity
water, removing up to 98% of
dissolved inorganics and over
99% of large dissolved organics,
colloids and particles.
Flow rates from 5 to 30 m
3
/hr.
Features & Benets
Low energy membranes result in
Frequency controlled variable speed
pump can save up to 50% of the
electrical power required by
conventional systems
lower operating pressures; cost
savings
5m pre-ltration included within
the unit for membrane protection
Programmable user interface;
simple operation, monitoring and
storage (14 days) of pressure, ow
rate, conductivity and temperature
values
Modem & RS232 connections
Dry run monitor; pump protection
Treated water diverted at start-up;
ensures water quality
Timed recirculation rinse; reduces
membrane fouling
Options
Anti-scalant/sodium bisulfate
dosing equipment
Output to PLC via analogue signal
pH control
Concentrate rinse valve
for conductivity monitoring
Applications
Boiler feed
Industrial process water
Cooling water
Reuse / recycling
Healthcare
Biotechnologies
Electronics
Hospitals
Chemical industry
Primary metals
Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Hydrex Chemicals
Hydrex 4000 water treatment
chemicals from Veolia Water
Solutions & Technologies should
be used for optimised operation.
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION Mega/AQF008_EN_V4.1 - Dec.13
SIRION

Mega
Feed Water Supply Quality
Potable water free from organic contamination, chlorine and suspended matter. A softened water supply is normally required.
Supply Pressure r a b 6 . x a m r a b 2 . n i m
Temperature C 0 3 . x a m C 2 . n i m
Electrical Supply
All models 380/415V, 3 phase, 50Hz standard.
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
System Performance
Model
Nominal Flows at 10C*
Permeate
Feed
Typical Salt Rejection
Pump Motor Size
*Flow rates are dependent on feed water quality and temperature, the above values are based on 1000 ppm TDS, 10C & SDI <3.
System Dimensions
Model
Height
Depth
Width
Weight (dry)
*If height is not an issue consider the more compact SIRION Maxi
All connections are union socket - PVC-U
Pipe Connections
Model
Feed
Permeate
Concentrate
m
3
/hr
m
3
/hr
kW
%
mm
mm
mm
kg
110 x 2
5
6.3
96-98
7.5
1750
900
4100
980
110 x 2*
110 x 2
DN 40
DN 40
DN 40
110 x 3
7.5
9.4
96-98
11
1850
900
4100
1100
110 x 3
110 x 3
DN 40
DN 40
DN 40
110 x 4
10
12.5
96-98
11
1850
900
4900
1150
110 x 4
110 x 4
DN 50
DN 40
DN 40
210 x 4
15
18.8
96-98
15
1850
900
4900
1200
210 x 4
210 x 4
DN 50
DN 50
DN 40
211 x 4
20
25
96-98
18.5
2150
900
4900
1350
211 x 4
211 x 4
DN 65
DN 50
DN 40
211 x 5
25
31.3
96-98
22
2255
900
5900
1700
211 x 5
211 x 5
DN 65
DN 65
DN 40
30
37.5
96-98
30
320 x 5
2280
900
5900
1700
320 x 5
320 x 5
DN 80
DN 65
DN 50
SIRION Multipure
TM
Reverse Osmosis Systems
SIRION Multipure
TM
reverse
osmosis systems are specically
designedto treat brackish waters.
They reject over 99% of the salt
contained within the feed water.
Flow rates for standard systems
range from 4.7 to 104.2 m
3
/hr for
feed waters of up to 5 000 ppm
(TDS.)
Features & Benets
Standardized and skid-mounted;
short lead times and quick start-up
Small footprint; easily integrated
into existing plant
Chemical pre-treatment; protects
the RO membranes
High pressure pump with variable
frequency drive; ecient and quiet
operation
State-of-the-art RO membranes
Flushing and chemical cleaning
system; removes salt deposits,
prevents scaling and maintains
system performance
Touch screen interface for easy
operation
PLC control
Applications
Production of potable water
Industrial process water
Agricultural irrigation
Industrial water reuse
Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Hydrex Chemicals
Hydrex 4000 water treatment
chemicals from Veolia Water
Solutions & Technologies should be
used for optimized plant operation.
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION Multipure/AQF0016_EN_V2.0
SIRION Multipure
TM
Equipment Performance & Dimensions
p m u P s e n a r b m e M s n o i s n e m i D l a n i m o N C 5 1 @ w o l F
Model Feed Permeate
Recovery
WxDxH Weight 1st array 2nd array Power
m
3
/hr m
3
/hr % m kg Quantity Quantity kW
Feed water TDS up to 1000 ppm
RO 100/1 5.94 4.17 70
RO 150/1 8.92 6.25 70
RO 225/1 14.29 9.38 70
RO 325/1 19.10 13.54 70
RO 425/1 23.39 17.71 75
RO 500/1 27.67 20.83 75
RO 600/1 32.94 25 75
RO 750/1 41.34 31.25 75
RO 850/1 47.41 35.42 75
RO 1100/1 61.19 45.83 75
RO 1300/1 72.13 54.17 75
RO 1450/1 80.66 60.42 75
RO 1800/1 100.13 75 75
RO 1900/1 105.7 79.17 75
RO 2100/1 116.82 87.5 75
RO 2200/1 122.39 91.67 75
RO 2500/1 139.07 104.17 75
Feed water TDS up to 3000 ppm
RO 100/3 6.41 4.17 70
RO 125/3 7.38 5.21 70
RO 200/3 12.78 8.33 70
RO 280/3 17.89 11.67 70
RO 375/3 22.18 15.75 70
RO 450/3 26.65 18.79 70
RO 550/3 32.44 23 70
RO 650/3 38.43 27.25 70
RO 780/3 46.21 32.63 70
RO 1000/3 55.48 41.67 75
RO 1175/3 65.28 48.96 75
RO 1350/3 75 56.25 75
RO 1500/3 83.33 62.5 75
RO 1700/3 94.57 70.83 75
RO 1800/3 100 75 75
RO 1900/3 105.56 79.17 75
RO 2100/3 116.82 87.5 75
RO 2400/3 133.51 100 75
Feed water TDS up to 5000 ppm
RO 100/5 6.33 4.17 70
RO 175/5 11.13 7.29 70
RO 250/5 15.93 10.42 70
RO 350/5 22.32 14.67 70
RO 400/5 25.46 16.75 70
RO 500/5 31.61 20.83 70
RO 600/5 38.46 25 70
RO 700/5 44.39 29.17 70
RO 900/5 53.57 37.5 70
RO 1100/5 65.48 45.83 70
RO 1250/5 74.4 52.08 70
RO 1550/5 92.26 64.58 70
RO 1650/5 98.21 68.75 70
RO 1750/5 104.17 72.92 70
RO 1950/5 116.07 81.25 70
RO 2150/5 127.98 89.58 70
y t i l a u Q y l p p u S r e t a W d e e F s n o i t a c i c e p S l a i r e t a M
Pressure Vessels FRP 400 psi Feed Water Design Temp. (C) 15
Pipework AISI 316L SCH40 for high pressure Max. SDI 3
Others: uPVC Max. Turbidity (NTU) 1
Skid Epoxy coated carbon steel Max. TOC (ppm) 3
Pump Material AISI 304 or 316L (depending on TDS) Iron (ppm) < 0.1
Pump Type Centrifugal submersible multistage sleeved Manganese (ppm) < 0.1
Control Cabinet Painted carbon steel to IP54 Free Chlorine (ppm) < 0.1
Membranes Polyamide spiral wound (8)
5x1.7x2.2
5x1.7x2.2
5x1.7x2.2
5.5x1.7x2.2
7.5x1.7x2.2
5.5x1.7x2.2
6.5x1.7x2.2
7.5x1.7x2.2
6.5x1.7x2.2
7.5x1.7x2.2
7.5x1.7x2.2
7.5x1.7x2.2
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
5x1.7x2.2
5x1.7x2.2
5x1.7x2.2
5.5x1.7x2.2
5.5x1.7x2.2
5.5x1.7x2.2
6.5x1.7x2.2
7.5x1.7x2.2
7.5x2x2.2
7.5x2x2.2
7.5x2x2.2
7.5x2x2.2
7.5x2x2.2
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
5x1.7x2.2
5x1.7x2.2
5.5x1.7x2.2
7.5x1.7x2.2
5.5x1.7x2.2
6.5x1.7x2.2
7.5x1.7x2.2
6.5x1.7x2.2
7.5x1.7x2.2
7.5x1.7x2.2
7.5x1.7x2.2
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
(9x2x2.2) + (9x1.5x2.2)
1400
1450
1600
1700
1900
2100
2200
2300
2500
3200
3450
3700
4300+4300
4550+4550
4800+4800
5000+5000
5500+5500
1400
1450
1500
1600
1800
2100
2350
2400
2575
3200
3450
3700
4000
4300+4300
4550+4550
4800+4800
5000+5000
5500+5500
970
1100
1400
1610
1600
1950
2200
2575
3200
3450
3700
4300+4300
4550+4550
4800+4800
5000+5000
5500+5500
2
3
6
8
12
12
15
18
20
24
30
30
42
42
48
54
60
2
3
6
8
12
12
15
18
20
24
30
30
36
42
42
48
54
60
3
6
8
12
12
15
18
20
24
30
30
42
42
48
54
60
2
3
3
4
6
8
10
12
15
18
18
24
24
30
30
30
36
2
3
3
4
6
8
10
12
15
18
18
24
24
24
30
30
30
36
3
3
4
6
8
10
12
15
18
18
24
24
30
30
30
36
7.5
9.2
11
18.5
18.5
22
26
30
30
37
45
55
63
75
75
75
92
13
11
13
18.5
18.5
22
30
30
37
45
55
55
63
75
75
92
92
92
11
13
22
22
22
30
37
37
55
55
63
75
92
92
92
110
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
SIRION
130 - 350 Series

Basic
Reverse Osmosis Systems
SIRION Basic reverse osmosis
systems produce high purity
water, removing up to 98% of
dissolved inorganics and over
99% of large dissolved organics,
colloids and particles.
Flow rates from 100 to
350 l/hr.
Features & Benets
Low energy membranes result in
lower operating pressures; cost
savings
Simple instrumentation with
manual pressure gauges and
manual ow-meters; low cost
Optimized ow: size ratio; space
saving and ecient
1m pre-ltration included within
unit; membrane protection
Programmable user interface;
simple operation, monitoring of
conductivity
Dry run monitor; pump protection
Timed recirculation rinse; reduces
membrane fouling
Options
Treated water diverted at start-up;
ensures water quality
Monitoring of temperature
Applications
Air conditioning
Heating system
Boiler feed water
Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Hydrex Chemicals
Hydrex 4000 water treatment
chemicals from Veolia Water
Solutions & Technologies should be
used for optimised operation.
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION Basic 130-350 Series/AQF059_EN_V3.1
Model 130 250 350
Nominal Flows at 12C
Permeate l/hr 100-130 200-250 300-350
Feed l/hr 125-175 250-335 375-470
Typical Salt Rejection % 96-98 96-98 96-98
Pump Motor Size kW 0.55 0.55 0.55
*Flow rates are dependent on feed water quality.
All capacity data is referenced to 12C water temperature and a feed water total salt contents of 750 ppm.
System Performance
Model 130 250 350
Height mm 1040 1260 1260
Depth mm 380 380 380
Width mm 600 600 600
Weight kg 59 61 68
System Dimensions
Model 130 250 350
Feed Water, Permeate, First Permeate, Concentrate 12 mm 12 mm 12 mm
Pipe Connections
Potable water free from organic contamination, chlorine and suspended matter. A softened water supply is normally required.
Supply Pressure min. 2 bar max. 6 bar
Temperature min. 5C max. 25C
Feed Water Supply Quality
230V, 50Hz standard.
Electrical Supply
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, contact details below.
SIRION

Basic (130 - 350 Series)


SIRION
5000 - 20000 Series

Basic
Reverse Osmosis Systems
SIRION Basic reverse osmosis
systems produce high purity
water, removing up to 98% of
dissolved inorganics and over
99% of large dissolved organics,
colloids and particles.
Flow rates from 5 to 20 m
3
/hr.
Options
Anti-scalant/sodium bisulfate
dosing equipment
Treated water diverted at start-up;
ensures water quality
Features & Benets
Low energy membranes result in
savings
5m pre-ltration included within
the unit for membrane protection
Programmable user interface;
simple operation, monitoring,
conductivity and temperature values
Dry run monitor; pump protection
Timed recirculation rinse; reduces
membrane fouling
Simple instrumentation with
manual pressure gauges and
manual ow-meters; low cost
Applications
Air conditioning
Heating system
Boiler feed water
Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Hydrex Chemicals
Hydrex 4000 water treatment
chemicals from Veolia Water
Solutions & Technologies should be
used for optimised operation.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION Basic 5000-20000 Series/AQF061_EN_V2.1
Visit our website:
www.veoliawaterst.com
Model 5000 7500 10000 15000 20000
Nominal Flows at 12C
Permeate m
3
/hr 5 7.5 10 15 20
Feed m
3
/hr 6.3 9.4 12.5 18.8 25
Typical Salt Rejection % 96-99 96-99 96-99 96-99 96-99
Pump Motor Size kW 7.5 11 11 15 18.5
*Flow rates are dependent on feed water quality and Temperature, the above values are based on 1000 ppm TDS, 12C.
Equipment Performance
Model 5000 7500 10000 15000 20000
Height mm 1800 1800 1800 1800 1800
Depth mm 860 860 860 860 860
Width mm 3350 3760 4775 4815 4900
Weight (dry) kg 950 1050 1100 1150 1300
System Dimensions
Model 5000 7500 10000 15000 20000
Feed DN40 DN40 DN50 DN50 DN65
Permeate DN40 DN40 DN40 DN50 DN50
Concentrate DN25 DN25 DN25 DN32 DN32
All connections are union socket - PVC-U.
Pipe Connections
Potable water free from organic contamination, chlorine and suspended matter. A softened water supply is normally required.
Supply Pressure min. 2 bar max. 6 bar
Temperature min. 5C max. 30C
Feed Water Supply Quality
All models 380/415V, 3 phase, 50Hz standard.
Electrical Supply
SIRION

Basic (5000 - 20000 Series)


For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
SIRION Sea Water
TM
Reverse Osmosis Systems
SIRION Sea Water
TM
reverse
osmosis systems are specically
designed to treat seawater.
They reject over 99% of the salt
contained within the feed water.
Flow rates for standard systems
range from 1 to 41 m
3
/hr for feed
waters of up to 36 000 ppm (TDS).
Features & Benets
Standardized and skid-mounted;
short lead times and quick start-up
Small footprint; easily integrated
into existing plant
Chemical pre-treatment; protects
the RO membranes
High pressure pump with variable
frequency drive; ecient and quiet
operation
Energy recovery device for high
ow rate models; energy savings
of 35-55%
State-of-the-art RO membranes
Flushing and chemical cleaning
system; removes salt deposits,
prevents scaling and maintains
system performance
Touch screen interface for easy
operation
PLC control
Applications
Production of potable water
Agricultural irrigation
Industrial process water
Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs to
ensure the long-term, ecient
operation of installed plant.
Hydrex Chemicals
Hydrex 4000 water treatment
chemicals from Veolia Water
Solutions & Technologies should be
used for optimized plant operation.
SIRION Sea Water
TM
Equipment Performance & Dimensions
Flow @ 20C
Recovery
Dimensions Membranes Pump
Model r e w o P y t i t n a u Q t h g i e W H x D x W e t a e m r e P d e e F
m
3
/hr m
3
/hr % m kg - kW
D-25 5.30 1.06 20
D-50 6.42 2.12 33
D-75 7.95 3.18 40
D-100 10.60 4.24 40
D-125 13.25 5.30 40
D-150 15.88 6.35 40
D-190-PX 19.88 7.95 40
D-230-PX 23.88 9.55 40
D-270-PX 26.55 11.15 42
D-360-PX 35.36 14.85 42
D-450-PX
D-450-T
44.17 18.55 42
D-530-PX 52.98 22.25 42
D-530-T 52.98 22.25 42
D-620-PX 61.90 26.00 42
D-620-T 61.90 26.00 42
D-710-PX 70.48 29.60 42
D-710-T 70.48 29.60 42
D-800-PX 79.45 33.37 42
D-800-T 79.45 33.37 42
D-890-PX 88.33 37.10 42
D-890-T 88.33 37.10 42
Material Specications
Low Pressure
Prelter Housing Polyamide (PA)
Filter Element Polypropylene
Dosing Pumps PVC head, Teon-coated EPDM diaphragm
Chemical Product Tanks PE
Flushing and Chemical Cleaning Tank FRP
Flushing and Chemical Cleaning Pump Stainless steel
Piping and Accessories PVC-U / PN-16
High Pressure
High-Pressure Pump Stainless Steel AISI 904-L / Super Duplex
(depending on the model)
Pressure Vessels FRP
RO Membranes Link crossed aromatic polyamide (8)
Piping and Accessories Stainless steel for seawater applications
AISI 904-L (Standard) ZERON/ 254 SMO (Options)
Skid Epoxy-painted carbon steel
Feed Water Supply Quality
Raw Water Design Temperature 0 2 C
Raw Water Maximum Turbidity 1 U T N
Raw Water Minimum Pressure 3 r a b
SDI <3
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION Sea Water/AQF0017_EN_V3.0
3x1.7x2.2
3x1.7x2.2
4x1.7x2.2
5x1.7x2.2
6x1.7x2.2
4x1.7x2.2
6.5x1.7x2.2
8x2x2.2
8.5x2x2.2
8.5x2x2.2
9x2x2.2
9x2x2.2
10x2x2.2
9x2x2.2
10x2.15x2.2
9.5x2.15x2.2
10x2.15x2.2
9.5x2.15x2.2
10x2.15x2.2
9.5x2.15x2.2
10x2.15x2.2
9.5x2.15x2.2
1600
1700
1800
1900
2000
2100
2200
3100
3400
3700
4025
3975
4325
4275
4525
4475
4530
4500
4535
4525
4600
4550
2
4
6
8
10
12
15
18
21
28
35
35
42
42
49
49
56
56
63
63
70
70
18.5
22
22
2x15
2x22
2x22
22+2.2
30+2.2
2x18.5+3
2x22+3
2x30+4
75
55+5.5
75
55+5.5
110
75+7.5
110
75+7.5
11.
90+7.5
132
44.17 18.55 42
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Ultraltration
Ultraltration is a membrane separation process similar to micro d n a n o i t a r t l
reverse osmosis. However, it diers in terms of the size of particles removed and
its operation. Ultraltration operates at low pressures and is capable of removing
suspended solids including t h g i e w r a l u c e l o m h g i h d n a s d i o l l o c , s e t a l u c i t r a p e n
dissolved materials.
Applications include:
Surface water
Borehole water
Swimming pool water
Recycling/reuse
RO feed water
Oil/water separation in emulsion
Recovery of metal particles
Regeneration of degreasing/cleaning solutions
Ultraltratioon
U
l
t
r
a


l
t
r
a
t
i
o
n
2.5 to 44
2.5 to 176
55
55
11 165 220
110 165 220
2.5 - 11 5 - 22 7.5 - 33 10 - 44
55 11 165 220
2236/2156* 2236/2156* 2252/2178* 2276/2194*
1648 1657 2635 2655
50 50 50
3 - 19 Aug.2013
Deionisation
There are many industrial processes in which the presence of any dissolved salts
in water can cause problems. Removing all the dissolved salts from water is called
deionisation or demineralisation. Processes that need high purity water include:
High pressure boilers
Chemical manufacture
Toiletries and cosmetics production
Humidication systems
Battery top-up
Surface nishing
For industrial processes requiring high purity water, the most widely used purication
technology is twin bed ion exchange deionisation. The ion exchange resins are
contained in two separate pressure vessels and ow through them in series. Raw
water enters the cation exchange vessel and passes down through the resin bed
where calcium, magnesium, sodium and other cations are removed from the water
in exchange for hydrogen ions. The water then passes through the anion exchange
vessel where chloride, sulfate, bicarbonate and other anions are removed in exchange
for hydroxide ions. When the hydrogen and hydroxide ions on the resins have been
replaced by the cations and anions from the water, the deionisation reaction stops
and the resins need to be regenerated.
Deionisationn
D
e
i
o
n
i
s
a
t
i
o
n
24r
1M
DeionisaIion SysIems
24r
1M
deionisaIion sysIems
Iypically produce waIer wiIh
a conducIiviIy oI less Ihen
25S]cm.
llow raIes Irom 60 to 400 IJhr.
leaIures & 8enehIs
CosI eecIive capiIal and
running cosIs Ior deionised waIer
producIion
kobusI skid and sIand design Ior
long liIe and reliabiliIy
OpIimised ow.size raIio, space
saving and emcienI
Pre-assembled, skid mounIed
sysIem, reduces insIallaIion cosIs
and ensures rapid sIarI-up Iime
SaIe operaIion, wiIh no mains
elecIrical connecIions
8aIIery operaIed conducIiviIy
meIer Ior sysIem qualiIy conIrol
and operaIion
Non-reIurn valves and break Ianks
can be hIIed iI required
Manually regeneraIed
ApplicaIions
LaboraIories
MeIal hnishing and surIace
IreaImenI
PC8 and semiconducIor rinsing
1oileIries and cosmeIics
Chemical diluIion
8aIIery Iop-up
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
24r
1M
5ystem Performance
ModeI
Maximum fIow 0 0 4 l]hr
l]hr
l]hr
l]hr
l
l
l
Minimum fIow 0 6
Dptimum fIow for Maximum Capacity 0 0 2
kegeneration 1ime 5 . I s r u o h
Pressure Loss at Maximum fIow 2 . 2 r a b
Pressure Loss at Dptimum fIow 5 . 0 r a b
Maximum fIow to Drain During kegeneration 0 0 7
muent VoIume per kegeneration 0 0 4
ChemicaI Usage per kegeneration
HCI (327) 5 . 3
NaDH (307) 7 . 2
Dutput per kegeneration
(!00 mgJI 1otaI Anion Load as CaCD
3
Inc. CD
2
& 5iD
2
) m
3
5
5ystem Dimensions, Weights & Connections
ModeI
Height 0 5 0 I m m
Depth 0 6 3 m m
Width 0 3 4 m m
kecommended Headroom 0 0 5 m m
Approx. 5ervice Weight 0 6 g k
Pipe Connections*
InIet (with !.5m tubing) 8 ] 3 s e h c n i
DutIet (with !.5m tubing) 8 ] 3 s e h c n i
Drain (with 4m tubing) 2 ] I s e h c n i
'3]8" male 8SP connecIions also supplied
1reated Water DuaIity
m c ] S y I i v i I c u d n o C l ] g m S D 1
24r
1M
5 2 < 0 I <
MateriaI 5pecications
Pressure VesseIs ComposiIe plasIic
Pipework PvC
5kid Lpoxy coaIed mild sIeel
ControI VaIves Manually operaIed ball Iype
feed Water 5uppIy DuaIity
PoIable waIer Iree Irom organic conIaminaIion, chlorine and suspended solids.
Supply Pressure. min. I.5 bar max. 6 bar
1emperaIure. min. 5C max. 30C
IectricaI 5uppIy
8aIIery required - 9v PP3 or equivalenI.
for higher ow rate appIications consuIt your IocaI VeoIia Water
5oIutions & 1echnoIogies company, detaiIs beIow.
vsL cur wchsLc.
www.veo|iawaterst.com
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC/24r//Q000!NV!.!
uo Lclipse
eionisaIion ysIems
Duo Lclipse" Iwo sIage deionisers
remove up Io 98 oI IoIal dissolved
solids and will Iypically produce
waIer wiIh a conducIiviIy oI less
Ihan 20 S]cm.
llow raIes Irom 25 to 4 m
3
h.
leaIures & 8enehIs
Skid-mounIed, sIandardised
sysIems, shorI lead-Iimes, quick
insIallaIion and sIarI-up
LlecIronic conIrol panel wiIh
indicaIion lamps, conducIiviIy
moniIor, manual override, simple
Io use, operaIional exibiliIy
ConducIiviIy conIrolled auIomaIic
regeneraIion, minimal operaIor
involvemenI
Dptions
kegeneranI sIorage sysIem wiIh
low level chemical swiIches, linked
Io Duo Lclipse" conIrol panel,
minimises chemical handling,
insumcienI chemicals alarm
lnleI carIridge hlIer, prevenIs
parIiculaIe maIIer Irom enIering
resin beds
Acid Iume sysIem Ior carboy
operaIion, reduces Iumes Io
aImosphere
ApplicaIions
lndusIrial process waIer
8oiler Ieed
MeIal hnishing
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
vsL cur wchsLc.
.veo|iaae.com
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC /uo cpsc//Q002SNV!.!
Duo Lc|ipe
5ystem Performance
ModeI 0 0 4 0 0 3 0 5 1
fIow kates m
3
0 . 4 - 0 . 1 0 . 3 - 5 . 0 5 . 1 - 5 2 . 0 r h /
Dperating Pressures 0 . 6 - 0 . 4 0 . 6 - 0 . 4 0 . 6 - 0 . 4 r a b
Pressure Loss at Max. fIow 0 . 3 8 . 2 6 . 1 r a b
kegeneration 1ime (50 Hz Max.) 0 . 3 5 . 3 8 . 2 s r u o h
Max. fIow to Drain m
3
0 . 4 8 . 2 0 . 2 r h /
uent VoIume per kegen. (Approx) m
3
0 . 2 6 . 1 0 . 1
ChemicaI Usage per kegen.
HCI (327 wJw) 5 3 0 2 0 1 l
l
l
HCI (287 wJw) 1 4 3 2 1 1
NaDH (307 wJw) 5 . 7 3 4 2 0 1
Dutput per kegen.
(!00 mgJI 1otaI Anion Load as CaCD3 m
3
0 0 1 0 6 5 2
Inc. CD2 & 5iD2)
5ystem Dimensions, Weight and Connections
ModeI 0 0 4 0 0 3 0 5 1
Height 0 5 0 2 5 6 9 1 5 0 5 1 m m
Depth 0 0 7 0 7 6 0 7 6 m m
Width (xc. kegen. Containers) 0 5 2 1 0 7 0 1 0 7 8 m m
kecommended Headroom 0 0 0 1 0 0 0 1 0 0 0 1 m m
kecommended kear Access 0 0 0 1 0 0 0 1 0 0 0 1 m m
Approx. 5ervice Weight 0 5 9 5 3 8 0 8 4 g k
InIet 1 1 1 s e h c n i
DutIet 1 1 1 s e h c n i
Drain 1 1 1 s e h c n i
1reated Water DuaIity
ModeI 0 0 4 0 0 3 0 5 1
1D5 0 2 < 0 1 < 0 1 < l / g m
Conductivity 0 2 < : e g a r e v A 0 3 < : m u m i x a M m c / S
MateriaI 5pecications
Pressure VesseIs ComposiIe plasIic
Pipework A8S and uPvC
5kid Lpoxy coaIed mild sIeel
ControI VaIves Noryl plasIic
ControI Cabinet lP54 enclosure
feed Water 5uppIy DuaIity
PoIable waIer Iree Irom organic conIaminaIion, chlorine and suspended solids.
1emperaIure. Min. 5C Max. 35C
IectricaI 5uppIy
240v or II0v single phase, 50]60 Rz.
for higher ow rate appIications consuIt your IocaI VeoIia Water 5oIutions & 1echnoIogies company, detaiIs beIow.
kapide" SIraIa
1win-bed Deionisers
wiIh ShorI Cycle kegeneraIion
kapide" SIraIa Iwin-bed
deionisers produce high puriIy
waIer Ior a range oI indusIrial
applicaIions. 1he unique design
oers savings oI up Io 40 on
running and euenI cosIs
compared Io convenIional ion
exchange sysIems.
llow raIes Irom 2.5 to !8 m
3
Jhr.
leaIures & 8enehIs
kegeneraIion in 30-45 minuIes
using SClON" Iechnology,
minimises down Iime, enhances
bacIerial conIrol, improves
chemical usage emciencies
PLC conIrol and Iacia mounIed
display, IaciliIaIes moniIoring
and operaIion
ConIinuous conducIiviIy moniIor
wiIh auIo service shuI-o and
alarm, ensures waIer qualiIy
ConIinual, inIermiIIenI or zero
recirculaIion oI waIer when Iank
reaches high poinI, operaIional
exibiliIy
Skid-mounIed, sIandardized
sysIems, shorI lead Iimes, quick
insIallaIion and sIarI-up
xtended kegeneration Dption
kemoves need Ior separaIe posI
IreaImenI
Capable oI producing waIer wiIh
<20 ppb oI reacIive silica, suiIable
Ior high and medium pressure
boiler-Ieed
Produces waIer oI <0.I s]cm,
polishing kO waIer
(SIraIa+ Model)
ApplicaIions
RealIhcare
PharmaceuIical
SurIace hnishing
Righ and medium pressure boiler
Ieed
kapide
1M
5trata+ Model
lnIegraIed polishing device (Ripol")
Produces waIer exceeding Ph Lur
and USP conducIiviIy requiremenIs
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
vsL cur wchsLc.
eo|iwterstom
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC/apdc Sraa//Q00!!NV!.2
kpide
M
Strt
quipment Performance
kapide
1
kapide a t a r t 5
1
5trata+
ModeI 4 !0 !8 4+ !0+ !8+
Maximum fIow m
3
]h 4 I0 I8 4 I0 I8
Minimum fIow m
3
]h 2.5 6.5 I4 2.5 6.5 I4
kegeneration 1ime minuIes 35 35 35 35 - 45' 35 - 45' 35 - 45'
Maximum fIow to Drain during
kegeneration m
3
]h 2.5 6.5 II.5 2.5 6.5 II.5
uent VoIume per kegeneration m
3
r
r
r
0.7 I.5 2.7 0.7 I.5 2.7
ChemicaI Usage per kegeneration
HCI (327) liIres 6.2 I5.4 27.8 6.2 I5.4 27.8
NaDH (327) liIres 5.8 I4.5 26.I 5.8 I4.5 26.I
8uIked uent pR 6 - 9 6 - 9 6 - 9 6 - 9 6 - 9 6 - 9
Dutput per kegeneration
(!00 mgJI 1otaI Anion Ioad as CaCD3
Inc CD2 & 5iD2) m
3
20.4 5I.6 93.6 I6.8 42 75.6
Power Consumption kW I.5 3 5.5 I.5 3 5.5
' kegeneraIion.
1he kapide
1M
SIraIa+ has a 35 minuIes regeneraIion Ior >IMO-cm (<IS]cm) waIer and up Io 45 minuIes regen Ior > I0MO-cm (<0.IS]cm)
quipment Dimensions
ModeI 4 !0 !8 4+ !0+ !8+
Height mm 2075 2I30 2230 2075 2I30 2230
Depth mm 900 II00 I300 900 II00 I300
Width mm I500 2000 2080 I500 2000 2080
kecommended Headroom mm I000 I000 I000 I000 I000 I000
Approx. 5ervice Weight kg 650 I550 I950 650 I550 I950
feed InIet mm 50 63 90 50 63 90
5ervice DutIet mm 40 50 63 40 50 63
kegeneration Water InIet mm 50 63 90 50 63 90
Drain mm 32 40 50 32 40 50
1reated Water DuaIity
m c - M y t i v i t s i s e k m c J 5 y t i v i t c u d n o C I J g m 5 D 1
kapide
1M
5trata e g a r e v a 5 . 0 < . x a m 2 . 0 < e g a r e v a 2 < . x a m 5 < I <
kapide
1M
5trata+ 0 I - I I . 0 - I 2 . 0 <
MateriaI 5pecications
Pressure VesseIs ComposiIe plasIic
Pipework uPvC
Pump 3I6 sIainless sIeel mulIisIage cenIriIugal
5kid Lpoxy coaIed mild sIeel
ControI VaIves Air operaIed diaphragm valves
ControI Cabinet Lpoxy coaIed sIeel Io lP54
feed Water 5uppIy DuaIity
Pressure min. 0.I bar max. I.25 bar
1emperaIure min. 5C max. 30C
IectricaI 5uppIy Dptions
400vAC ( 380-4I5) , 3 Phase , 50 RZ
380] 480 vAC, 3 phase 60RZ
220]227 vAC, 3 phase 60RZ
Air 5uppIy
5.5 - 6.0 8ar, lnsIrumenI ualiIy, 5 liIres per minuIe inIermiIIenI
for higher ow rate appIications consuIt your IocaI VeoIia Water
5oIutions & 1echnoIogies company, contact detaiIs beIow.
Continuous Electrodeionisation (CEDI)
Continuous Electrodeionisation (CEDI) is a technology combining ion exchange
resins and ion-selective membranes with direct current to remove ionised species
from water. It overcomes the limitations of ion exchange resin beds, notably the
release of ions as the beds exhaust and the associated need to change or
regenerate the resins. Reverse osmosis (and sometimes membrane degassing) is
typically used prior to CEDI to ensure that the CEDI stack is not overloaded with high
levels of salts.
Applications include:
Pharmaceutical
High pressure boiler feed
Humidication systems
Microelectronics
Central laboratory
Continuous Eleectrodeiionisatiion (CEDDI)
C
E
D
I
Ultraviolet Disinfection
Ultraviolet (UV) technology is an e r e t a w r o f y g o l o n h c e t e e r f - l a c i m e h c e v i t c e
disinfection.
UV disinfection can be applied to:
Process water
Wastewater
An ultraviolet (UV) disinfection system transfers electromagnetic energy from a
mercury arc lamp to organisms genetic material. UV radiation, generated by an
electrical discharge through mercury vapour, penetrates the microorganisms and
destroys or slows down their ability to reproduce. The eectiveness of a UV disinfection
system depends on the characteristics of the water, the intensity of UV radiation, the
amount of time the microorganisms are exposed to the radiation, and the reactor
conguration. For any one treatment plant, disinfection success is directly related to
the concentration of colloidal and particulate constituents in the water.
Ultraviolet DDisiinfectioon
U
V
D
i
s
i
n
f
e
c
t
i
o
n
UV Water Treatment
UV Disinfection - Industrial range
Ultra Violet (UV) technology is an
eective chemical-free
technology for water disinfection.
Capacity:
up to 112 m
3
/hr for disinfection
Features & benets:
Compact, easy to install ; can be
mounted horizontally or vertically
depending the models
Conveniently t into existing
pipework
Easy to maintain and operate
Low operation cost
Silent operation
Chemical-free process ; safety
Environmentally-friendly:
No production of toxic by-products
Typical lamp operating life of up to
16,000 hours
No eect on pH, colour, avour or
aroma
No detrimental eect on product
stability
No residue
Overdosing not possible
UV Chamber in 316L stainless steel
construction
Quick replacement of Arc Tubes
Optional UV monitor
Applications
Production of pure water
Electronics and semiconductor
industry
General industries
Destruction of residual ozone
after disinfection and
sanitisation (deozonisation)
Related services
Local after-sales service and
support teams offer preventative
and corrective maintenance
programs to ensure the long-term,
efficient operation of installed
plant.
Visit our website:
www.veoliawaterst.com
Model Max Flow
m
3
/hr
Power
W
Dia
mm
Length
mm
+/- 5mm
Weight
kg
Connections
PN16 Flange
A B Lamp Total Empty Full
UV 35 i 3.5 3.6 80 105 63 920 5 6 1
UV 64 i 6.4 7.2 80 105 102 958 7 12.5 1
UV 127 i 12.7 14.1 140 170 102 1385 9 17.5 2
UV 230 i 23 23 270 320 102 1385 9 17.5 2
UV 468 i 46.8 56 270 320 168 1437 25 52 3
UV 900 i 89 112 550 630 206 1985 46 107 6
A Disinfection at 26mJ/cm
2
RED MS2 Phage, 95% T10 transmittance at the end of lamp life
B Disinfection at 26mJ/cm
2
RED MS2 Phage, 98% T10 transmittance at the end of lamp life
Specications
Material AISI 316L : DN 1.4404 Water Temperature +5 to +40C
Finish External Passivated & Electropolished Maximum CIP Temperature 95C
Protection IP65 / NEMA 4 Finish internal: As made pipe
and tube, welds left as laid,
electropolished and passivated
Finish internal: As made pipe
and tube, welds left as laid,
electropolished and passivated
Pressure 9 bar, max operating* * UV 900i 6 Bar max operating pressure
Mounting Horizontal or Vertical** *Note UV900i cannot be mounted vertically
UV Chamber Specications
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/UV Water Treatment - Industrial range/ AQF060_EN_V2.0
Enclosure Material Powder Coated Carbon Steel
Power Supply 230V 50/60Hz
Cable 5m maximum Control Box to UV Chamber
Ambient +5 to +40C
Indicator Lamps Lamp On + Fault
Output (VFC) Lamp On
UV 35 i UV 468 i IP65 / NEMA 4
Dimensions/Weight
400 x 300 x 155 mm
(excl Brackets) 15kg
UV 900 i IP55 / NEMA12
Dimensions/Weight
600 x 400 x 210 mm
(excl Brackets) 19kg
Control Box Specications
Long life 254Nm amalgam lamp.
Lamp Life Expected 16,000 hours (12,000 Hours UV230i, UV468i & UV900i) Warranty 9,000 hours. Based on less than 4 start/stop cycles per 24 hours.
UV Lamp Specications
All units are supplied with a Certicate of Conformity.
Documentation
UV Water Treatment - Industrial range
UV Water Treatment
UV Disinfection - Pharma range
Ultra Violet (UV) technology is an
eective chemical-free
technology for water disinfection:
Versions built to cGMP
requirements available for
pharmaceutical and sanitary
applications.
Capacity:
up to 112 m
3
/hr for disinfection
up to 19.6 m
3
/hr for deozonisation
Features & benets:
Compact, easy to install ; can be
mounted horizontally or vertically
depending the models
Conveniently t into existing
pipework
Easy to maintain and operate
Low operation cost
Silent operation
Chemical-free process ; safety
Environmentally-friendly:
No production of toxic by-products
Typical lamp operating life of up to
16,000 hours
No eect on pH, colour, avour or
aroma
No detrimental eect on product
stability
No residue
Overdosing not possible
UV Chamber in 316L stainless steel
construction
Quick replacement of Arc Tubes
Optional UV Monitor
Applications
Production of pure water
Pharmaceutical
Destruction of residual
ozone after disinfection and
sanitisation (deozonisation)
Cosmetics and toiletries industry
Related services
Local after-sales service and
support teams offer preventative
and corrective maintenance
programs to ensure the long-term,
efficient operation of installed
plant.
Visit our website:
www.veoliawaterst.com
Model Max Flow
m
3
/hr
Power
W
Dia
mm
Length
mm
+/- 5mm
Weight
kg
Connections
TC Triclamp
Inches
A B Lamp Total Empty Full
UV 36P 3.6 0.45 80 105 63 920 5 6 1
UV 72P 7.2 1.42 80 105 102 958 7 12.5 1
UV 141P 14.1 2.3 140 170 102 1385 9 17.5 2
UV 230P 23 4.5 270 320 102 1385 9 17.5 2
UV 560P 56 8.4 270 320 168 1437 20 47 3
UV 1120P 112 19.6 550 630 206 1985 39 100 6
A Disinfection at 26mJ/cm
2
RED MS2 Phage, 98% T10 transmittance at the end of lamp life
B Deozonisation is based on a 90% reduction of Ozone at 98% T10 transmittance at the end of lamp life
Specications
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/UV Water Treatment - Pharma range / AQF078_EN_V1.1
Enclosure Material Powder Coated Carbon Steel
Power Supply 230V 50/60Hz
Cable 5m maximum Control Box to UV Chamber
Ambient +5 to +40C
Indicator Lamps Lamp On + Fault
Output (VFC) Lamp On / Low UV
UV 36 P UV 560P IP65 / NEMA 4
Dimensions/Weight
400 x 300 x 155 mm
(excl Brackets) 18kg
UV 1120P IP55 / NEMA12
Dimensions/Weight
600 x 400 x 210 mm
(excl Brackets) 22kg
Control Box Specications
Long life 254Nm amalgam lamp.
Lamp Life Expected 16,000 hours (12,000 Hours UV230P, UV560P & 1120P) Warranty 9,000 hours. Based on less than 4 start/stop cycles per 24 hours.
UV Lamp Specications
All units are supplied with a Certicate of Conformity, with material certicates, lamp output certicates & FDA Validation pack.
Documentation
UV Water Treatment - Pharma range
Material AISI 316L : DN 1.4404 Water Temperature +5 to +40C
Finish External Passivated & Electropolished Maximum CIP Temperature 95C
Protection IP65 / NEMA 4 Finish, Internal < 0.5m Ra
Pressure 9 bar, max operating* * UV1120P 6 Bar max operating pressure
Mounting Horizontal or Vertical** ** UV1120P cannot be mounted vertically
**Photo includes the UV Monitor.
UV Chamber Specications
Multi-Technology Solutions
Water treatment technologies are dierentiated by their ability to treat di t n e r e
types of contaminants. It is often necessary to combine dierent treatment technologies
in order to produce a suitable quality of water for an application.
Applications include:
Filtration, softening and RO for utility feed and process water
Filtration, softening, RO and DI for healthcare, microelectronics and laboratories
Filtration, softening, twin pass RO and CEDI for pharmaceutical
RO & CEDI for high pressure boiler feed
RO & CEDI for healthcare, microelectronics and central laboratory
The existence of similar applications and thus water requirements across dierent
businesses has encouraged water treatment companies to propose pre-packaged
multi-technology solutions. Typically such solutions are skid-mounted or containerised
and have smaller footprints than combined independent technologies. They also
have the advantage of being pre-piped and pre-congured prior to delivery for quick
installation and start-up. In addition, the control systems are specically designed to
monitor and control the combined technologies making for an e cient and easy to
use system.
Multi-Technooloogy Soluutions
M
u
l
t
i
-
T
e
c
h
n
o
l
o
g
y

S
o
l
u
t
i
o
n
s
lonPkO
1M
LX
keverse Osmosis & CLDl
1he lonPkO
1M
LX sysIems produce
high puriIy waIer wiIh low
bacIeria levels.
llow raIes Irom 500 Io
!000 IJhr.
leaIures & 8enehIs
Dptions
validaIion pack wiIh schedules,
lnsIallaIion QualihcaIion (lQ) and
OperaIional QualihcaIion (OQ)
ApplicaIions
PharmaceuIical l-8uIIon securiIy proIecIion
RMl. inIuiIive & simple Io use ,
process inIormaIion, perIormance
calculaIions, warnings, alarms
displayed on screen
SIainless sIeel skid , longeviIy
AesIheIically pleasing , moulded
covers
CompacI skid , small IooI prinI
SIandardised single-skid design,
shorI lead Iimes and quick sIarI-up
llexible design soluIions , easy
upgrade , opIions
Conhgurable seI poinIs
Combined drain , simpliciIy
Supplied wiIh Iull lacIory
AccepIance 1esI (lA1)
lnIegral auIomaIic saniIizaIion
(AuIoSan) , minimal operaIor
involvemenI, reliable & repeaIable

MicroelecIronics
CenIral laboraIory
(analyIical waIer grade 2)
General manuIacIuring
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
Rydrex Chemicals
Rydrex 4000 waIer IreaImenI
chemicals Irom veolia WaIer
SoluIions & 1echnologies should be
used Ior opIimised planI operaIion.
Degasser Ior perIormance
enhancemenI
vsL cur wchsLc.
www.veo|iawaterst.com
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC/onO ` Mk2//Q0SSNV!.!
|onPkO
1M
LX
5ystem Performance & Dimensions
IDNPkD LX MkII ModeI
NominaI fIows*
!5C & ! bar
feed
Product Water
feed Water, Conductivity & CD
2
Nominal llows' are given Ior indicaIion, more accuraIe pro|ecIions can be obIained using Ihe SysIem Sizing Programme (SSP)
MateriaI 5pecications
5ofteners
5oft Water 1ank
kD Pressure VesseIs
Pipe Work
frame
kD Pump
Power cabinet
kD Iements
CDI ModuIe
Noryl Reads PolyeIhylene Lined vessels
Righ DensiIy PolyeIhylene
PvC and hbreglass epoxy
cPvC & uPvC
304 SIainless SIeel
304 & 3I6 SIainless SIeel
PainIed Mild SIeel
4" x 40" 1hin-lilm ComposiIe
kobusI Wide Cell 1echnology
feed Water kequirements
for higher ow rate appIications consuIt your IocaI VeoIia Water 5oIutions & 1echnoIogies company, detaiIs beIow.
General
Pressure
1emperaIure
1oIal Dissolved Solids (1DS)
lron
Manganese
lree Chlorine
1oIal Rardness
PoIable waIer Iree Irom organics, colloids
and suspended solids (SDl < 3)
3.5 bar minimum, 6 bar maximum
5 - 25C
< I000 ppm
< 0.I ppm
< 0.05 ppm
< 0.25 ppm wiIh AcIivaIed Carbon CarIridge lilIers
< 0.02 ppm wiIh PleaIed DepIh CarIridge lilIers
< 400 ppm as CaCO
3
m
3
]hr
m
3
]hr
2-!0
0.75
0.50
Righ
3-!0
I.I0
0.75
Medium
3-!8
I.I0
0.75
Righ
4-!0
I.50
I.00
Medium
4-!8
I.50
I.00
Righ
kecovery
Dimensions
Connections
5aIt 1ank
5aIt Usage per kegeneration
5oftener Dutput per kegeneration
(200mgJI 1otaI Hardness as CaCD
3
)
IectricaI 5uppIy (50Hz)
IectricaI 5uppIy (60Hz)
Power Consumption
Width
Depth
Height
Weight
Dia x Height
feed
Product
keturn
Drain

mm
mm
mm
kg
mm
kg
m
3
65-75
800 (950 wiIh opIional Degasser)
II00 (I300 wiIh opIional Degasser)
I570
660
550 x 850
6
I0
3]4" 8SP (G) lemale
25mm uPvC SockeI Union
25mm uPvC SockeI Union
40mm uPvC SockeI Union
380]400]4I5v . 3phase . 50Rz . 6.2 kvA
220]380]400]4I5]480v . 3phase . 60Rz . 7 kvA
Depends on operaIing condiIions - See SSP
650 650 650 650
uaIIro
MuIi-1echnoogy SouIion
uaIIro sysIems suppy high
puriIy waIer Ior a range oI
appicaIions.
Nomina ow raIes Irom
500 to 3000 IJhr.
8asic conhguraIion
CarIrige hIraIion -
carbon]parIicuaIe
MuIi-purpose Iank
kO wiIh SS pressure vesses
SIanar OpIions
Pre kO OpIions
8ase exchange soIIeners
CausIic osing
CarIrige hIer opIions. exIrue
carbon, granuar carbon,
5m peaIe
MoniIoring. chorine, harness
PosI kO OpIions
Degasser Ior CO2 remova
CLD
Service emineraisaIion
PvC or SS pipe work
Uv
MoniIoring opIions, incuing 1OC
OuIeI conIro opIions
WiInesse lA1
leaIures & 8enehIs
Ski-mounIe, pre-assembe,
pre-IesIe, space saving, shorI ea
Iimes, quick sIarI-up
Microprocessor conIroer wiIh RM
screen, simpe moniIoring an
operaIion
SIainess sIee kO vesses wiIh
saniIary ow paIh esign
RM has secure access keys an
aarms, prevenIs accienIa or
unauIhorise usage
nIegraIe Ceaning n Pace (CP)
Iank, mainIains kO membrane
perIormance
uaIIro-S Moe
Designe Ior Ihe pharmaceuIica
inusIry
WiInesse lA1
vaiaIion package meeIs GMP
requiremenIs
Deivere pre-IesIe &
pre-vaiaIe
AppicaIions
CosmeIics
nusIria aboraIories
MicroeecIronics
8oier Iee
8ioIechnoogy
ReaIhcare
PharmaceuIica proucIs
keaIe Services
Loca aIIer-saes service an supporI
Ieams oer prevenIaIive an
correcIive mainIenance programs
Io ensure Ihe ong-Ierm, emcienI
operaIion oI insIae panI.
Ryrex Chemicas
Ryrex 4000 waIer IreaImenI
chemicas Irom veoia WaIer
SouIions & 1echnoogies shou be
use Ior opIimise panI operaIion.
vsL cur wchsLc.
wwwveo|iawaterstcom
n kccpng wh hc progrcssvc naurc o hc conpany wc rcscrvc hc rgh o ancnd dcas whou nocc
VWS C/T/OCQuaro
TM
/Q7NV
uattro"
quipment Performance
ModeI 500 !000 2000 3000
ModeI 500 !000 2000 3000
ominaI Iow kates*
Permeate** 0 0 0 3 0 0 0 2 0 0 0 1 0 0 5 r h / l
eed 0 1 1 4 0 4 7 2 0 7 3 1 0 9 6 r h / l
Concentrate 0 1 1 1 0 4 7 0 7 3 0 9 1 r h / l
Pump Motor 5ize 5 . 7 5 . 5 0 . 4 0 . 3 W k
kecovery (maximum***) 3 7 %
''Nominal ows are based on operaIion oI kO]CLDl sysIem aI I5C (60l), SDl<3 and are dependenI on Ieed waIer qualiIy
''Maximum ouIleI pressure oI 0 - 4 bar (I5 - 60 PSl), dependenI on Ihe sizing program, siIe condiIions and cusIomer requiremenIs
'''WiIh CLDl opIion and CLDl concenIraIe recycled
Connections & Dimensions
InIet Union 2 3 5 2 0 2 0 2 m m
DutIet Union 5 2 0 2 5 1 5 1 m m
DutIet 1ricIamp 5 2 0 2 5 1 0 1 m m
Drain Union 0 5 m m
h t p e D h t d i W t h g i e H s n o i s n e m i D
AII modeIs 0 0 3 1 0 5 2 2 0 6 0 2 m m
MateriaI 5pecications
Pre kD Pipework uPvC
5ofteners RDPL and GkP ComposiIe
Cartridge iIter Housing Polypropylene
MuIti-purpose 1ank RDPL
keverse Dsmosis - High Pressure Pipework & VesseIs 3I6L SIainless SIeel
Pipework uPvC
Pipework Dption 3I6L SIainless SIeel
5kid 304 SIainless SIeel
ControI Cabinet PainIed Mild SIeel
eed Water kequirements
CeneraI PoIable waIer Iree Irom organics, colloids and suspended maIIer, SDl<3
ree ChIorine <0.25 mg]l'
1emperature 5-30C (45-80l)
Pressure 4-6 bar (60-90 PSl)
'WiIh acIivaIed carbon carIridge hlIers hIIed
1ypicaI 1reated Water DuaIity (kDJCDI)
Conductivity* <0.2 S]cm
8acteria <I0 cIu]ml (wiIh Uv opIion), <I00 cIu]ml (wiIhouI Uv opIion)
1DC <500 ppb
'Depends on Ieed waIer qualiIy, ow raIe & producI opIion selecIed.
or higher ow rate appIications consuIt your IocaI VeoIia Water 5oIutions & 1echnoIogies company, contact detaiIs beIow.









No Legionella baceia
kecycling ae. > 90
Clarication & Flotation
Clarication is a multi-step process that reduces turbidity and suspended matter. It
is also used to reduce iron and remove colour, taste and odour in the water by adding
oxidising agents such as chlorine. Clarication consists of three stages: coagulation,
occulation and sedimentation.
During the coagulation stage, chemical coagulants or pH-adjustment chemicals are
used to destabilise the particles. During the occulation stage, other chemicals are
added which encourage the previously destabilised particles to stick together and
form ocs. During sedimentation, the ocs settle by gravity and separate from the
water.
Applications include:
Primary clarication of wastewater
Treatment of biolter backwash water
Clarication of trickling lter e uents
Storm water treatment
Tertiary polishing or phosphorus removal
Drinking water treatment, both ground and surface waters
Giardia and cryptosporidium removal
Pre-treatment of industrial process waters
Recycling/reuse
Flotation DAF is a process using air dissolved in water in order to achieve solid/liquid
separation.
In order to increase the process e ciency, chemical additives are normally dosed.
Coagulation followed by occulation inside the treated uid is achieved.
Coagulation is meant to destabilise solid particles in stable equilibrium inside
the uid, while e r o m d n a r e g g i b o t n i s e l c i t r a p e h t r e h t a g o t t n a e m s i n o i t a l u c c o
extended ocs.
Claricationn & Flotatioon
C
l
a
r
i


c
a
t
i
o
n
&

F
l
o
t
a
t
i
o
n
Actio Mini
The Ultimate Microsand
Enhanced Clarier
The pre-engineered Actio Mini is
a very compact standard package
plant for drinking water treatment,
municipal wastewater treatment
as well as industrial process water
and wastewater treatment and
reuse. The process is a highly
ecient and proven clarication
technology based on a strong 20+
year operating experience and over
750 references worldwide (2012).
In Actio Mini, water is
occulated with microsand and
polymer. The microsand enhances
the formation of robust ocs
and acts as ballast, signicantly
increasing their settling velocity.
The unique characteristics of the
resulting microsand ballasted ocs
allow for clarier designs with
very short retention times, high
rise rates and extremely compact
system footprints that are up
to 50 times smaller than other
clarication processes of similar
capacity. A hydrocyclone ensures
the microsand continuous cleaning,
recovery and reuse in the process.
Unit ow rates:
- Drinking and process water:
from 3 to 7 m
3
/hr
- Wastewater:
from 3 to 15 m
3
/hr
Features & Benets
High treatment efficiency: Turbidity
and TSS removal up to > 99%; treats all
water and wastewater sources
Extremely quick start-up time: Reaches
treatment efficiency within few
minutes
Process stability: The microsand
buffers the effect of raw water flow
or load variations, making the process
very user friendly and easy to operate
Quick optimization: Short hydraulic
retention time makes it feasible for the
process to adjust quickly to changing
raw water quality
Efficient use of chemicals: Microsand
ballasted flocculation and settling
helps to avoid common chemical
overdosing to achieve good
clarification performance
Efficient in cold water applications:
Suitable for use also in Nordic regions
Compact design: Can be easily
integrated and retrofitted into existing
structures
Modular: Units may be combined to
achieve treatment of high flow rates
Related Services
Local after-sales service and support
teams offer preventive and corrective
maintenance programs to ensure long-
term, efficient operation of installed
plant.
Applications
Surface and ground water treatment
Very high or very low turbidity water
and wastewater
Treatment of water with high natural
organic matter (colour, TOC)
Efficient treatment of algae,
phosphorus, heavy metals, oil &
grease, particle counts, crypto and
giardia, coliforms, etc.
Primary, secondary and tertiary
clarification of wastewater
Treatment of biofilter backwash
water and trickling filter effluents
Stormwater and combined sewer
overflow treatment, reverting to
effluent polishing during dry weather
Industrial process water treatment
for cooling tower make-up or prior to
demin plants
Pre-treatment to membrane and ion
exchange systems
Industrial wastewater treatment
in all market segments, including
leachate and run-off water
Recycling/Reuse of municipal and
industrial effluents
Hydrex Chemicals
Hydrex 3000 & 6000 water
treatment chemicals from Veolia
Water Solutions & Technologies
should be used for optimized plant
operation.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Actio Mini/AQF0124_EN_V1.1
Visit our website:
www.veoliawaterst.com
Process & Drinking Water Application 3(*) - 7 m
3
/H
Industrial & Municipal Wastewater Application 3(*) - 15 m
3
/H
Length 3 m
Width 1 m
Height 2.7 m
Operating Weight 3.4 tonne
Total Installed Power max. 4kW
Supply Power (Standard) (**) 380V x 3phase x 50/60 Hz
Recirculation Pump 3.5 m
3
/H x 20mH x 2.2 kW
Chemical Dosing Pump (Standard) (***) PAC, Acid, Alkali, Polymer
Monitoring Instrument (Standard) (****)
1 x pH at Coagulation Tank
3 x Flowmeter at Inlet, Recirculation & Sludge Line
1 x Pressure at Hydrocyclone Inlet
2 x Turbidity Meter at Inlet & Outlet
Equipment Performance & Dimensions
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, contact details below.
Actio Mini
(*) In case of the operation at < 5 m
3
/H, the separation of sludge from microsand should be investigated, due to over-mixing in Maturation Tank.
(**) 220V x 3 phase x 50/60Hz is optional.
(***) Additional chemical dosing or dierent type of chemical should be discussed prior to the order.
(****) Additional monitoring should be discussed prior to the order.
Actio Mini is supplied as a complete functional system, including chemical preparation and dosing equipment as well as integrated PLC & SCADA.
It can be supplied as a stand-alone unit or pre-installed in a 20 container.
AcIio Pack
Righ kaIe Clariher
1he pre-engineered AcIio
Pack is a compacI sIandard
package planI Ior drinking waIer,
process waIer wasIewaIer
IreaImenI and waIer re-use.
emcienI and proven clarihcaIion
Iechnology, which uses a micro-
sand ballasI IhaI IuncIions as a
seed, enhancing oc IormaIion
and seIIling.
llow raIes.
Drinking and process waIer.
Irom 40 to 320 m
3
Jhr per uniI
WasIewaIer.
Irom 80 to 640 m
3
Jhr per uniI
leaIures & 8enehIs
1urbidiIy removal >90, IreaIs all
waIer sources, highly emcienI
keacIs quickly Io changing raw
waIer qualiIy, provides consisIenIly
high euenI qualiIy
CompacI design, much smaller
Ihan convenIional clarihers, easily
inIegraIed inIo exisIing works
Modular, uniIs may be combined
Ior higher ow raIes
kapid sIarI-up, Iully operaIional
in less Ihan 20 minuIes
Pre-engineered, minimal civil
engineering, shorI lead Iimes,
IasI commissioning
Over 500 AcIio insIallaIions
worldwide, paIenIed and proven
Iechnology Irom veolia WaIer
SoluIions & 1echnologies
kelaIed Services
Local aIIer-sales service and supporI
Ieams oer prevenIaIive and
correcIive mainIenance programs
Io ensure Ihe long-Ierm, emcienI
operaIion oI insIalled planI.
ApplicaIions
Primary clarihcaIion oI wasIewaIer
1reaImenI oI biohlIer backwash
waIer
ClarihcaIion oI Irickling hlIer
euenIs
SIorm waIer IreaImenI, reverIing
Io euenI polishing during dry
periods
1erIiary polishing or phosphorus
removal
Drinking waIer IreaImenI, boIh
ground and surIace waIers
Giardia and crypIosporidium
removal
Pre-IreaImenI oI indusIrial process
waIers
kecycling]reuse
Rydrex Chemicals
Rydrex 3000 & 6000 waIer IreaI-
menI chemicals Irom veolia WaIer
SoluIions & 1echnologies should be
used Ior opIimised planI operaIion.
1he process is a highly
vsL cur wchsLc.
www.veo|iawaterst.com
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC//co ack//Q004oNV!.2
Actio Pack
quipment Performance
1ypicaI Design fIows (m
3
Jhr)
s e n i L o w 1 e n i L e n D
Water
APW-! 0 8 0 4
APW-2 0 6 1 0 8
APW-3 0 2 3 0 6 1
APW-4 0 4 6 0 2 3
Wastewater
APWW-! 0 6 1 0 8
APWW-2 0 2 3 0 6 1
APWW-3 0 4 6 0 2 3
APWW-4 0 8 2 1 0 4 6
lor poIable]process waIer, clarihed waIer IurbidiIy is normally reduced Io 0.5 N1U or less aI rise raIes oI beIween 40-60 m]hr. lor wasIewaIer, Ihe reducIion
is Iypically 85-95 oI SS, 50-60 oI COD and 85-95 oI P aI rise raIes oI beIween 80-I20 m]hr.
Unit Dimensions
Max Height (AssembIed) h t d i W h t g n e L
s r e t e m s r e t e m s r e t e m r e t a W
APW-! 4.2
4.8
4.8
4.8
8 . 1 1 . 4
4.2
4.8
4.8
4.8
APW-2 4 . 2 1 . 5
APW-3 7 . 2 7 . 5
APW-4 6 . 3 2 . 8
Wastewater
APWW-! 8 . 1 1 . 4
APWW-2 4 . 2 1 . 5
APWW-3 7 . 2 7 . 5
APWW-4 6 . 3 2 . 8
for higher ow rate appIications consuIt your IocaI VeoIia Water 5oIutions & 1echnoIogies company, contact detaiIs beIow.
Actio Turbo Pack
The Ultimate Microsand
Enhanced Clarier
The pre-engineered Actio Turbo
Pack is a very compact standard
package plant for drinking water
treatment, municipal wastewater
treatment as well as industrial
process water and wastewater
treatment and reuse. The process
is a highly ecient and proven
clarication technology based
on a strong 20+ year operating
experience and over 750 references
worldwide (2012).
In Actio Turbo, water is
occulated with microsand and
polymer in a Turbomix draft tube.
The microsand enhances the
formation of robust ocs and acts
as ballast, signicantly increasing
their settling velocity. The unique
characteristics of the resulting
microsand ballasted ocs allow
for clarier designs with very short
retention times, high rise rates
and extremely compact system
footprints that are up to 50 times
smaller than other clarication
processes of similar capacity.
A hydrocyclone ensures the
microsand continuous cleaning,
recovery and reuse in the process.
Unit ow rates from
1 500 m
3
/d to 43 000 m
3
/d.
Features & Benets
High treatment efficiency: Turbidity
and TSS removal up to > 99%; treats all
water and wastewater sources
Extremely quick start-up time: Reaches
treatment efficiency within few
minutes
Process stability: The microsand
buffers the effect of raw water flow
or load variations, making the process
very user friendly and easy to operate
Quick optimization: Short hydraulic
retention time makes it feasible for the
process to adjust quickly to changing
raw water quality
Efficient use of chemicals: Microsand
ballasted flocculation and settling
helps to avoid common chemical
overdosing to achieve good
clarification performance
Efficient in cold water applications:
Suitable for use also in Nordic regions
Compact design: Can be easily
integrated and retrofitted into existing
structures
Modular: Units may be combined to
achieve treatment of high flow rates
Related Services
Local after-sales service and support
teams offer preventive and corrective
maintenance programs to ensure long-
term, efficient operation of installed
plant.
Applications
Surface and ground water treatment
Very high or very low turbidity water
and wastewater
Treatment of water with high natural
organic matter (colour, TOC)
Efficient treatment of algae,
phosphorus, heavy metals, oil &
grease, particle counts, crypto and
giardia, coliforms, etc.
Primary, secondary and tertiary
clarification of wastewater
Treatment of biofilter backwash
water and trickling filter effluents
Stormwater and combined sewer
overflow treatment, reverting to
effluent polishing during dry weather
Industrial process water treatment
for cooling tower make-up or prior to
demin plants
Pre-treatment to membrane and ion
exchange systems
Industrial wastewater treatment
in all market segments, including
leachate and run-off water
Recycling/Reuse of municipal and
industrial effluents
Hydrex Chemicals
Hydrex 3000 & 6000 water
treatment chemicals from Veolia
Water Solutions & Technologies
should be used for optimized plant
operation.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Actio Turbo Pack/AQF0123_EN_V1.1
Visit our website:
www.veoliawaterst.com
Model
Flows (m
3
/d)
60 m/h 80 m/h
(Drinking / Process Water)
120 m/h
(Municipal / Industrial Wastewater)
ACP2-15 1 500 2 000 3 000
ACP2-30 3 000 4 000 6 000
ACP2-40 4 500 6 000 9 000
ACP2-45 6 000 8 000 12 000
ACP2-55 9 000 12 000 18 000
ACP2-60 12 000 16 000 24 000
ACP2-70 18 750 25 000 37 500
ACP2-75 21 375 28 500 42 750
Model
Dimensions (mm)
Length Width
Height
(Tank) (Assembled)
ACP2-15 4 156 2 029 2 859 4 479
ACP2-30 5 744 2 254 3 175 4 794
ACP2-40 6 824 2 580 3 315 4 970
ACP2-45 6 871 2 668 3 175 5 177
ACP2-55 8 374 3 278 3 175 5 177
ACP2-60 9 352 3 990 3 175 5 177
ACP2-70 10 651 4 500 3 650 5 648
ACP2-75 11 830 4 612 3 650 5 648
Equipment Performance
Unit Dimensions
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company, contact details below.
Actio Turbo Pack
Membrane Bioreactors & Biological
Wastewater Treatment
Membrane Bioreactors (MBR) are used to treat industrial and municipal wastewaters to
produce high quality e uents suitable for water reuse applications either directly
or following a reverse osmosis treatment stage. MBR combine two basic processes:
biological treatment and membrane separation in either a single tank or separate
tanks. The biological breakdown of the pollution takes place in an aerated reactor
containing suspended microorganisms (biomass or activated sludge). The key
dierentiator of MBR is that the biological process is coupled with membranes
for biomass s a h c u s , s e s s e c o r p n o i t a r a p e s l a n o i t n e v n o c g n i s u f o d a e t s n i n o i t a r t l
clarication and otation.
Advantages over conventional systems:
Small footprint and quick start-up
Complete suspended solids removal
High load rate capability
High removal of COD and nutrients (nitrogen, phosphorous)
Low sludge production
No sludge bulking
E uent disinfection; barrier against pathogens, such as chlorine-resistant
organisms, cryptosporidium and giardia
Applications include:
Small or medium sized industrial or municipal e uent treatment plants
Temporary solutions during refurbishment or upgrade work
Recycling for boiler feed, process water, aquifer recharge, public utility
Membrane BBiooreactorrs & Bioological
Wastewaterr Treeatmennt
M
B
R

&

B
i
o
l
o
g
i
c
a
l

w
a
s
t
e
w
a
t
e
r

t
r
e
a
t
m
e
n
t
Biosep Pack 3
Membrane Bioreactor (MBR)
Features & Benets
Standardised systems; short lead
times and quick start-up
Skid-mounted, modular design;
easily integrated into existing
plant, extensible
Integrated ltration and membrane
cleaning system
Suitable for all types of euent,
easily integrated into a wide variety
of biological designs; highly exible
Compared to conventional
activated sludge:
Compact solution; less equipment
and civil engineering, simplied
treatment line
No settler; no risk of sludge loss,
performance independent of
sludge index
Long biomass retention time; high
COD removal, including slowly
biodegradable COD
Applications
Small or medium sized industrial
or municipal euent treatment
plants (800 to 10,000 PE)
Temporary solutions during
refurbishment or upgrade work
Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Hydrex Chemicals
Hydrex 4000 & 7000 water
treatment chemicals from Veolia
Water Solutions & Technologies
should be used for optimized plant
operation.
Biosep Pack is added to a
biological aeration tank. The
membrane bioreactor replaces
the traditional settling system
and separates perfectly the
purifying biomass from the
treated euent through
microltration. The microltered
water is of excellent
bacteriological quality and
removal of TSS is guaranteed at
any time.
Flow rates from 4 to 110 m
3
/hr.
Biosep Pack
Equipment & Dimensions
Membrane Tank
Membrane
Power Backwash
Air
BSP 1 M 5
BSP 1 M 10
BSP 1 M 15
BSP 2 M 20
BSP 2 M 30
04 - 12
08 - 33
12 - 56
16 - 66
24 - 110
1
1
1
2
2
2.5
3
4
3
4
6 - 8
6 - 8
6 - 8
6 - 8
6 - 8
20
29
52
29
52
0.006 - 6
0.006 - 6
0.006 - 6
0.006 - 6
0.006 - 6
2
3 or 4
3 or 6
3 or 4
3 or 6
5.5
11
15
18.5
30
150
300
450
600
900
10
12
15
24
30
1
1
1
2
2
Typical Performances
COD < 50mg/l*
BOD
5
< 5 mg/l
Suspended Solids < 3mg/l (detectable threshold)
Total Nitrogen < 10-15 mg/l
M
o
d
e
l
s
N
e
t

F
l
o
w

R
a
t
e
s


(
m
3
/
h
r
)
N
u
m
b
e
r

o
f

M
e
m
b
r
a
n
e

M
o
d
u
l
e
s
D
i
a
m
e
t
e
r

(
m
)
T
o
t
a
l

H
e
i
g
h
t

(
m
)
*
N
e
t

V
o
l
u
m
e


(
m
3
)
A
n
t
i
f
o
a
m

D
o
s
i
n
g

P
u
m
p

(
l
/
h
)


D
o
s
a
t
r
o
n

o
r

B
a
c
k
w
a
s
h

P
u
m
p

S
o
l
u
t
i
o
n

(
m
3
/
h
)
*
*

A
i
r

B
l
o
w
e
r

P
o
w
e
r

(
k
W
)
A
i
r

B
l
o
w
e
r

F
l
o
w

R
a
t
e

(
m
3
/
h
)
M
a
i
n

C
o
n
t
r
o
l

C
e
n
t
e
r

P
o
w
e
r

(
k
W
)
9882 FICHE BIOSEP PACK (Gb):Mise en page 1 29/05/08 22:29 Page 2
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Biosep Pack/AQF0034_EN_V3.1 - 11.2012
Total Phosphorous < 0.5 - 2 mg/l
Turbidity < 1 NTU
E.coli < 1000/100ml
Material Specications
Membrane Tank Fiber Reinforced Platsic (FRP)
Access Fittings (ladder, platform, guard rails) Epoxy Coated or 304 L
Skid PE
Piping PE / PVC / PVC-C
For higher ow rate applications consult your local Veolia Water Solutions & Technologies company.
N
u
m
b
e
r

o
f

M
e
m
b
r
a
n
e

T
a
n
k
s
Antifoam
skid
*Membrane tank height must be selected with site constraints (aeration basin and discharges levels)
**2 backwash solutions are available, it must be chosen depending on potable water availability (3m
3
/h at 1 bar minimum)
*COD depends on the non-biodegradable (hard COD) fraction
disk" lilIer
8io-discs
1he Lcodisk" lilIer is a combina-
Iion oI Lcodisk" and Drum lilIer
used Io separaIe IreaIed waIer
Irom sludge.
CapaciIy Irom !00 Io !0 000 P
leaIures & 8enehIs
keliabiliIy oI Ihe hxed culIure
Simple and robusI
Lasy Io operaIe
Righ-qualiIy and durable maIerial
Minimal visual impacI
SilenI and odour Iree
Lconomic and quick Io insIall
Low operaIing cosIs
CompacI and modular process
Dptions
Subsoil-uniI version. Minimal
visual impacI , Only requiring Ihe
excavaIion oI a Irench and pouring
oI a concreIe IoundaIion plaIe
CombinaIion wiIh a drum hlIer.
3 sIandard size drum hlIers
(I m]hr, 2 m]hr and 3 m]hr)
lilIraIion panel mesh. 2 m
- I m]possible dierenI grades.
ApplicaIions
8iological wasIewaIer IreaImenI
kural communiIies
CampsiIes
RoIels
ConsIrucIion siIes
kesIauranIs
kelaIed Services
Local aIIer-sales service and
supporI Ieams oer prevenIaIive
and correcIive mainIenance
programs Io ensure Ihe long-Ierm,
emcienI operaIion oI insIalled
planI.
n kccpng wh hc progrcssvc naurc o hc conpany wc rcscrvc hc rgh o ancnd dcas whou nocc
VWS C/T/OCcodsk
TM
cr/QS9NV
vsL cur wchsLc.
www.veo|iawaterst.com

2
Number of Discs Motor kating VoIume of
8io-disc 1ank(s)
codisk" fiIter: 5ubsoiI-unit 5ize kW m
8DJDf- 520J!0 or 20 or 30 !00 S20 S3 0.37 2.S0
8DJDf - 780J!0 or 20 or 30 !S0 7S0 !2S 0.S0 4.!4
8DJDf -!040J!0 or 20 or 30 200 !040 !oo 0.S0 S.00
8DJDf -!300J!0 or 20 or 30 2S0 !300 20S 0.7S o.o4
8DJDf -!560J!0 or 20 or 30 300 !So0 249 0.7S 7.S0
8DJDf -!820J!0 or 20 or 30 3S0 !S20 290 !.!0 9.!4
8DJDf -2080J!0 or 20 or 30 400 20S0 332 !.!0 !0.00
8DJDf -2600J!0 or 20 or 30 S00 2o00 4!S !.S0 !2.S0
DutIet vaIues mgJI
8DD <2S
CDD <!2S
155 <3S
1P <2 (wLh an addLcn c cC
3
)
quipment Performance
5pecic 5tandard DutIet kequirements
Lcodisk" Ii|ter
gn varies according Io IreaImenI requiremenI, IemperaIure and planI sizes. 1he Iollowing daIa are given as an
indicaIion.
Evaporation
Evaporation is a process of physical separation which can be applied to liquid
systems.
Evaporation technology is a natural and clean method of separation; for this reason
it has become recognised as BAT (Best Available Technology) in several European
Directives for waste treatment.
Typical applications include:
Wastewater treatment
Reduction of volumes to be disposed
ZLD
Recycling and Reuse
Exploitation of exceeding thermal energy
Production of high quality deionised water for boiler feed and cooling circuits
make-up
Treatment of cooling towers blow-down
Evaporation
E
v
a
p
o
r
a
t
i
o
n
n kccpng wh hc progrcssvc naurc o hc conpany, wc rcscrvc hc rgh o ancnd dcas whou nocc.
VWS C/T/OC/vacd
TM
C //Q073NV!.!
vsL cur wchsLc.
www.veo|iawaterst.com
Mobile Water Solutions
Veolia Water Solutions & Technologies oers Aquamove service to industries using
puried water for their production lines or utilities. Aquamove constitutes a large
eet of mobile water treatment units, that may be deployed as stand-alone units
or combined to form complete systems: skid-mounted systems, containers and
trailers.
Aquamove oers emergency hire, planned temporary hire and long-term contract for:
Boiler, turbine feed water
Process water
Cooling water
Drinking water
Wastewater
Aquamove safeguards the production of the puried water when clients are facing:
Plant commissioning
Filling pressure boilers
Equipment breakdown
Plant downtime for maintenance purposes
Raw water changes
Peak demand
Process trial validation
Technologies available:
Reverse osmosis
Deionisation
Ion exchange polishing
Softening
Filtration
Activated carbon
Clarication
Evaporation,
Mobile Wateer SSolutionns
M
o
b
i
l
e

W
a
t
e
r
S
o
l
u
t
i
o
n
s
Water Treatment Chemicals
Veolia operates more than 5000 water treatment facilities across the world,
including process, boiler feed, cooling water, waste water and sludge treatment. Our
research & development team constantly innovates and delivers new technologies
that provide optimum solutions to environmental problems with a high-value to our
clients businesses. Hydrex chemicals are committed to complying with all chemical
regulations (ie Reach, Biocides Directive in Europe,).
Veolia Water Solutions & Technologies o e h t e s i m i t p o o t m a r g o r p x e r d y H s r e
entire water cycle, chemical consumption, operating and maintenance costs.
Protecting water treatment systems against scale deposition, corrosion, fouling, etc.
Reducing unnecessary downtime
Ensuring optimum productivity
Preventing and reducing environmental risks
Allowing energy saving
Hydrex range includes:
1000 Series:Total boiler water treatment chemicals
2000 Series: Closed and open cooling system treatment programs
3000 Series: Drinking water production
4000 Series: Eective membrane antiscalants and cleaners approval by major
membrane manufacturers
5000 Series: Industrial maintenance chemicals
6000 Series: State-of-the-art clarication and wastewater chemistry and
application experience
7000 Series: Biocides with a broad spectrum of activity and Legionella control
8000 Series: Established process and specialty chemicals
9000 Series: Wide range of other applications
W
a
t
e
r
T
r
e
a
t
m
e
n
t

C
h
e
m
i
c
a
l
s
Consumables & Spare Parts
Veolia Water Solutions & Technologies works in partnership with its customers to
ensure the optimal running of their water treatment facilities.
Veolia Water Solutions & Technologies oers a wide range of consumables and spare
parts.
Cartridge lters
Reverse osmosis membranes
Ion exchange resins
Activated carbon and other ltration media
CEDI stacks
Valves
Instrumentation
Dosing systems
UV systems
Test kits, etc.
C
o
n
s
u
m
a
b
l
e
s
&

S
p
a
r
e

P
a
r
t
s
FILO
TM
Carb
Cartridge Filters
Features & Benets
Eective carbon surface area
for good chlorine reduction
Low pressure loss
Long life
Several lengths available:
9"
3/4
; 20" ; 26" ; 30" ; 40"

Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Chlorine reduction
Taste and odour removal
Membrane pre-treatment
Process water
Organic reduction in plating baths
Removal of surfactant

The FILO
TM
Carb cartridge lters
are a range of activated carbon
lters.
Nominal rating: 10 m.

200
100
0
3
2
1
0

0 2 4 6
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
p
s
i
d
)
Flow Rate (l/min) for Water at 20C
Performance
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
m
b
a
r
)
Applications
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILO
TM
Carb/AQF113_EN_V1.2
FILO
TM
Carb
Specications
Ordering Information
Length Micron End Fiting Part Number
9" 3/4 10 CFCBYS9510
CFCBZD9514
SOE CODE 3 CFCBZD9540
26" 10 SOE CODE 3 CFCBZD9541
SOE CODE 3 CFCBZE9540
CFCBZE9512
SOE CODE 3 CFCBZF9512
CFCBZF9513
DOE
DOE
DOE
DOE
20"
30"
40"
10
10
10
Filtration Media Steam activated, Acid washed coal
Material Specications
Recommended Operating Conditions
Max. Temperature 50C (120F)
Max. Recommended Dierential Pressure 1.5 bar (22 psid)
Dimensions
Outside Diameter 2.7"
Inside Diameter 1.1"
Performance
Chlorine Reduction per 10" based on 2 ppm Inlet Concentration 22700 litres @ 3.8 l/min (6000 gallons @ 1 gpm)
FILO
TM
Carb-HP
Cartridge Filters
Features & Benets
Eective carbon surface area
for good chlorine reduction
Low pressure loss
Long life
Several lengths available:
9"
3/4
; 20" ; 30" ; 40"

Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Chlorine reduction
Taste and odour removal
Membrane pre-treatment
Process water
Organic reduction in plating baths
Removal of surfactant

The FILO
TM
Carb-HP cartridge
lters are a range of high
performance activated carbon
lters.
Nominal rating: 1 m.

400
200
0
6
4
2
0

0 2 4 6
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
p
s
i
d
)
Flow Rate (l/min) for Water at 20C
Performance
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
m
b
a
r
)
Applications
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILO
TM
Carb-HP/AQF114_EN_V1.2
FILO
TM
Carb-HP
Specications
Ordering Information
Filtration Media Steam activated, Acid washed coal
Material Specications
Recommended Operating Conditions
Max. Temperature 50C (120F)
Max. Recommended Dierential Pressure 1.5 bar (22 psid)
Dimensions
Outside Diameter 2.7"
Inside Diameter 1.1"
Performance
Chlorine Reduction per 10" based on 2ppm inlet Concentration 76000 litres @ 3.8 l/min (20000 gallons @ 1 gpm)
Length Micron End Fiting Part Number
9" 3/4 1 CFCBYS9511
20" 1 CFCBZD9515
SOE CODE 3 CFCBZE9541
CFCBZE9513
SOE CODE 3 CFCBZF9541
CFCBZF9514
DOE
DOE
DOE
DOE
30" 1
40" 1
FILO
TM
Pleat
Cartridge Filters
Features & Benets
Cost eective high surface area
Absolute rating from 1 to 25
microns
Long life
Several lengths available:
9"
3/4
; 20" ; 30" ; 40"
Endcaps available
FDA approved
All polypropylene construction

Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Water pre-ltration
Water nal ltration

The FILO
TM
Pleat cartridge lters
are dedicated to water pre-
ltration and nal ltration of a
wide range of water treatment
applications.

Absolute rating from 1 to 25 m.

Applications
Performance
200
100
0
3
2
1
0

0 10 20 30
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
p
s
i
d
)
Flow Rate (l/min) for Water at 20C
(Performance FILO
TM
Pleat 10")
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
m
b
a
r
)
1

m
5

m
10

m
2
5
m
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILO
TM
Pleat/AQF115_EN_V1.1
FILO
TM
Pleat
Specications
Ordering Information
Filtration Media Polypropylene
End Caps Polypropylene / Nylon
Material Specications
Recommended Operating Conditions
Max. Temperature 65C (150F)
Max. Recommended Dierential Pressure 2.5 bar
Max. Dierential Pressure 4 bar
Dimensions
Outside Diameter 2.7" (68 mm)
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
DOE CFYKYS9410 DOE CFYKZE9411
CODE 7 CFYKYS9450 CODE 7 CFYKZE9451
CODE 3 CFYKYS9440 CODE 3 CFYKZE9441
DOE CFYOYS9411 DOE CFYOZE9411
CODE 7 CFYOYS9450 CODE 7 CFYOZE9452
CODE 3 CFYOYS9440 CODE 3 CFYOZE9441
DOE CFYTYS9410 DOE CFYTZE9410
CODE 7 CFYTYS9450 CODE 7 CFYTZE9450
CODE 3 CFYTYS9440 CODE 3 CFYTZE9440
DOE CFZDYS9410 DOE CFZDZE9410
CODE 7 CFZDYT9450 CODE 7 CFZDZE9450
CODE 3 CFZDYS9440 CODE 3 CFZDZE9440
DOE CFYKZD9411 DOE CFYKZF9410
CODE 7 CFYKZD9451 CODE 7 CFYKZF9450
CODE 3 CFYKZD9441 CODE 3 CFYKZF9440
DOE CFYOZD9411 DOE CFYOZF9410
CODE 7 CFYOZD9451 CODE 7 CFYOZF9450
CODE 3 CFYOZD9441 CODE 3 CFYOZF9440
DOE CFYTZD9410 DOE CFYTZF9410
CODE 7 CFYTZD9450 CODE 7 CFYTZF9450
CODE 3 CFYTZD9440 CODE 3 CFYTZF9440
DOE CFZDZD9410 DOE CFZDZF9410
CODE 7 CFZDZD9450 CODE 7 CFZDZF9450
CODE 3 CFZDZD9440 CODE 3 CFZDZF9440
25
9" 3/4
20"
30"
40"
1
5
10
25
1
5
10
25
1
5
10
25
1
5
10
FILO
TM
Pleat-HP
Cartridge Filters
Features & Benets
Cost eective high surface area
Absolute rating from 0.6 to 40
microns
Long life
Several lengths available:
10" ; 20" ; 30"
Endcaps available: DOE, Code 7
Code 3
FDA approved
All polypropylene construction

Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Water pre-ltration
Water nal ltration

The FILO
TM
Pleat-HP cartridge
lters are oering an absolute
rated polypropylene media
with a broad range of chemical
compatibility.
The graded lter density along
with the optimised pleating
gives FILO
TM
Pleat-HP an
exceptional lifetime.

Absolute rating from 0.6 to 40 m
(> 99.99% retention at micron
rating)

Applications
Performance
100
50
0
1
0

0 10 20
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
p
s
i
d
)
Flow Rate (l/min) for Water at 20C
(Performance FILO
TM
Pleat 10")
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
m
b
a
r
)
0
.6

m
1
.2

m
5
m
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILO
TM
Pleat-HP/AQF116_EN_V1.4
Filtration Media Polypropylene
End Caps Polypropylene
Material Specications
Recommended Operating Conditions
Max. Continuous Temperature 60C (140F)
Steam Sterilisation Can be repeatedly stem sterilised or autoclaved at up to 130C
Max. Forward Dierential Pressure 4 bar at 25C
Dimensions
Outside Diameter 2.7" (68 mm)
Material Specication Micron End Fiting Part Number
DOE CFYGYT9410
CODE 7 CFYGYT9450
CODE 3 CFYGYT9440
DOE CFYKYT9410
CODE 7 CFYKYT9451
CODE 3 CFYKYT9440
DOE CFYOYT9410
CODE 7 CFYOYT9450
CODE 3 CFYOYT9440
CODE 9 CFYOYT300682
10 CODE 9 CFYTYT300683
25 CODE 9 CFZDYT300684
40 CODE 9 CFZFYT300685
DOE CFYGZD9410
CODE 7 CFYGZD9450
CODE 3 CFYGZD9440
DOE CFYKZD9410
CODE 7 CFYKZD9450
CODE 3 CFYKZD9440
DOE CFYOZD9410
CODE 7 CFYOZD9450
CODE 3 CFYOZD9440
CODE 9 CFYOZD300686
10 CODE 9 CFYTZD300687
25 CODE 9 CFZDZD300688
40 CODE 9 CFZFZD300689
DOE CFYGZE9410
CODE 7 CFYGZE9450
CODE 3 CFYGZE9440
DOE CFYKZE9410
CODE 7 CFYKZE9450
CODE 3 CFYKZE9440
DOE CFYOZE9410
CODE 7 CFYOZE9451
CODE 3 CFYOZE9440
0.6
1.2
5
30"
0.6
1.2
0.6
1.2
5
10"
5
20"
FILO
TM
Pleat-HP
Specications
Ordering Information
FILO
TM
Spun
Cartridge Filters
Features & Benets
High ow rates
Low pressure loss
High dirt holding capacity
Long life
Fast rinse up to 18 M
Several lengths available:
9"
3/4
; 20" ; 30" ; 40"
FDA approved

Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
High Purity Water

The FILO
TM
Spun cartridge lters
are a range of nominal rated
depth liquid lters (polypropylene).
Rating from 1 to 50 m.

Applications
Performance
0 20
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
m
b
a
r
)
Flow Rate (l/min) for Liquid at 20C
100
75
50
25
0
1

m
5

m
10

m
20 m
50 m
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILO
TM
Spun/AQF117_EN_V1.2
Filtration Media Polypropylene
End Caps Polypropylene
FILO
TM
Spun
Specications
Ordering Information
Material Specications
Recommended Operating Conditions
Max. Temperature 65C (150F)
Max. Recommended Dierential Pressure 2 bar (30 psid)
Max. Dierential Pressure 4 bar @ 20C (68F)
Dimensions
Outside Diameter 2.5"
Inside Diameter 1.1"
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
9" 3/4
1
DOE CFYKYS9300
30"
1
DOE CFYKZE9300
CODE 8 CFYKYS9370 CODE 8 CFYKZE9370
CODE 3 CFYKYS9341 CODE 3 CFYKZE9341
5
DOE CFYOYS9300
5
DOE CFYOZE9300
CODE 8 CFYOYS9370 CODE 8 CFYOZE9370
CODE 3 CFYOYS9341 CODE 3 CFYOZE9342
10
DOE CFYTYS9300
10
DOE CFYTZE9301
CODE 8 CFYTYS9370 CODE 8 CFYTZE9370
CODE 3 CFYTYS9341 CODE 3 CFYTZE9341
20
DOE CFZDYS9300
20
DOE CFZDZE9300
CODE 8 CFZDYS9370 CODE 8 CFZDZE9370
CODE 3 CFZDYS9341 CODE 3 CFZDZE9340
50 DOE CFZGYS9300 50 DOE CFZGZE9300
40"
1
DOE CFYKZF9300
CODE 8 CFYKZF9370
CODE 3 CFYKZF9341
5
DOE CFYOZF9300
20"
1
DOE CFYKZD9300 CODE 8 CFYOZF9370
CODE 8 CFYKZD9370 CODE 3 CFYOZF9341
CODE 3 CFYKZD9341
10
DOE CFYTZF9300
5
DOE CFYOZD9300 CODE 8 CFYTZF9370
CODE 8 CFYOZD9370 CODE 3 CFYTZF9341
CODE 3 CFYOZD9341
20
DOE CFZDZF9300
10
DOE CFYTZD9300 CODE 8 CFZDZF9370
CODE 8 CFYTZD9370 CODE 3 CFZDZF9340
CODE 3 CFYTZD9341 50 DOE CFZGZF9300
20
DOE CFZDZD9300
50"
1 DOE CFYKZG9300
CODE 8 CFZDZD9370 5 DOE CFYOZG9300
CODE 3 CFZDZD9340 20 DOE CFZDZG9300
50 DOE CFZGZD9300 50 DOE CFZGZG9300

FILO
TM
Spun-HP
Cartridge Filters
Features & Benets
High ow rates
Low pressure loss
High dirt holding capacity
Long life
Fast rinse up to 18 M
Several lengths available:
9"
3/4
; 20" ; 30" ; 40"
FDA approved

Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
High Purity Water

The FILO
TM
Spun-HP cartridge
lters are a range of absolute
rated depth liquid lters
(polypropylene).
Absolute rating from 1 to 20 m.

Applications
400
300
200
100
0
7
6
5
4
3
2
1
0

0 8 16
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
p
s
i
d
)
Flow Rate (l/min) for Liquid at 20C
Performance
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
m
b
a
r
)
1

m
5

m
10 m
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILO
TM
Spun-HP/AQF118_EN_V1.3
Filtration Media Polypropylene
End Caps Polypropylene
FILO
TM
Spun HP
Specications
Ordering Information
Material Specications
Recommended Operating Conditions
Max. Temperature 65C (150F)
Max. Recommended Dierential Pressure 2 bar (30 psid)
Cleaning and Sterilisation
Max. Dierential Pressure 4 bar @ 20C (68F)
FILO
TM
Spun-HP can be repeatedly (up to 25 times) steam sterilised in situ or autoclaved up to 130C
(266F). FILO
TM
Spun-HP lters can be sanitised with hot water at up to 90C (400 hours in 20 minutes
cycles) and are compatible with a wide range of chemicals.
Dimensions
Outside Diameter 2.5"
Inside Diameter 1.1"
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
DOE CFYFYS9310 DOE CFYFZE9310
CODE 3 CFYFYS9340 CODE 3 CFYFZE9340
CODE 7 CFYFYS9350 CODE 7 CFYFZE9350
DOE CFYKYS9310 DOE CFYKZE9310
CODE 3 CFYKYS9340 CODE 3 CFYKZE9340
CODE 7 CFYKYS9350 CODE 7 CFYKZE9350
DOE CFYOYS9310 DOE CFYOZE9310
CODE 3 CFYOYS9340 CODE 3 CFYOZE9341
CODE 7 CFYOYS9350 CODE 7 CFYOZE9350
DOE CFYTYS9310 DOE CFYTZE9310
CODE 3 CFYTYS9340 CODE 3 CFYTZE9340
CODE 7 CFYTYS9350 CODE 7 CFYTZE9350
DOE CFZDYS9310
CODE 3 CFZDYS9340
CODE 7 CFZDYS9350
DOE CFYFZD9310 DOE CFYFZF9310
CODE 3 CFYFZD9340 CODE 3 CFYFZF9340
CODE 7 CFYFZD9350 CODE 7 CFYFZF9350
DOE CFYKZD9310 DOE CFYKZF9310
CODE 3 CFYKZD9340 CODE 3 CFYKZF9340
CODE 7 CFYKZD9350 CODE 7 CFYKZF9350
DOE CFYOZD9310 DOE CFYOZF9310
CODE 3 CFYOZD9340 CODE 3 CFYOZF9340
CODE 7 CFYOZD9350 CODE 7 CFYOZF9350
DOE CFYTZD9310 DOE CFYTZF9310
CODE 3 CFYTZD9340 CODE 3 CFYTZF9340
CODE 7 CFYTZD9350 CODE 7 CFYTZF9350
40"
0.5
1
5
10
30"
0.5
1
5
10
20"
0.5
1
5
10
9" 3/4
0.5
1
5
10
20
FILO
TM
Mem
Cartridge Filters
Features & Benets
High ow rates
Hydrophilic PES membrane
Validated membrane
Integrity testable
Full traceability

Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Sterile Filtration
High Purity Water

The FILO
TM
Mem constitutes a
range of pleated membrane
cartridge lters for microbial
reduction for pharmaceutical
and electronic applications.

Quality
Manufactured in a controlled
environment
Manufactured in accordance
with GMP
100% ushed with puried water
100% integrity tested
Materials meet 21CFR part 177
and USP class VI requirements
Full validation guide available

Applications
100
0 10 l/min 20 l/min
50
Typical initial clean media dierential pressure
per 250 mm (10") cartridge for water at 20C, 1 cp
1
Performance
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
m
b
a
r
)
D
i

e
r
e
n
t
i
a
l

P
r
e
s
s
u
r
e

(
p
s
i
d
)
0
.
2

m
0
.
4
5

m
0
.
1

m
Visit our website:
www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILO
TM
Mem/AQF119_EN_V1.3
Filtration Media Polyethersulphone
Support Polyester
Cage and Core Polypropylene
O-ring Seal Silicone
End Cap Nylon
Reinforcing Ring Stainless Steel
FILO
TM
Mem
Specications
Ordering Information
Material Specications
Recommended Operating Conditions
Max. Continuous Operating Temperature 60C (140F)
Cleaning and Sanitisation
Max. Dierential Pressure (forward) 4.0 bard (60 psid) @ 40C (104F) ; 1.7 bard (25 psid) @ 90C (194F)
FILO
TM
Mem cartridge can be autoclaved up to 10 times up to 130C or steam sterilised up to 130C
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
DOE CFYCYT9410 DOE CFYBYT9410
CODE 3 CFYCYT9440 CODE 3 CFYBYT9440
CODE 7 CFYCYT9451 CODE 7 CFYBYT9450
CODE 9 CFYCYT9460 DOE CFYCYT9411
DOE CFYEYT9410 CODE 3 CFYCYT9441
CODE 3 CFYEYT9440 CODE 7 CFYCYT9452
CODE 7 CFYEYT9450
CODE 9 CFYEYT9460 DOE CFYBZD9410
CODE 3 CFYBZD9444
DOE CFYCZD9410 CODE 7 CFYBZD9450
CODE 3 CFYCZD9440 DOE CFYCZD9411
CODE 7 CFYCZD9451 CODE 3 CFYCZD9441
CODE 9 CFYCZD9460 CODE 7 CFYCZD9452
DOE CFYEZD9410
CODE 3 CFYEZD9440
0.1
DOE CFYBZE9410
CODE 7 CFYEZD9450 CODE 3 CFYBZE9440
CODE 9 CFYEZD9460 CODE 7 CFYBZE9450
DOE CFYCZE9411
DOE CFYCZE9410 CODE 3 CFYCZE9441
CODE 3 CFYCZE9440 CODE 7 CFYCZE9451
CODE 7 CFYCZE9450
CODE 9 CFYCZE9460
DOE CFYEZE9411
CODE 3 CFYEZE9440
CODE 7 CFYEZE9450
CODE 9 CFYEZE9460
0.1
20"
30"
10"
0.2
0.2
0.1
0.2
0.2
30"
0.45
0.45
0.45
0.2
10"
0.2
20"
FILO
TM
Mem-P (Pharmaceutical applications) FILO
TM
Mem-E (Electronic applications)
Integrity Test
Minimum bubble point: 49 psig (3.4 bar)
Diusional ow in water per 10": 16 cc/min at 41 psig (2.8 bar)
RO Membranes
VWSRO-XTLE-2521
Extra Low Energy Element
Part Number
Nominal Area
m
Permeate Flow Rate
m
3
/d (usgpd)
Minimum Salt Rejection
(%)
MBROYL0700 1.1 1.2 (320) 98
Type
Conguration: Spiral Wound
Membrane Polymer: Composite Polyamide/Polysulphone
Test Conditions
500 ppm NaCl solution, 7 bar (100 psi), 25C, pH 6 7, Permeate Recovery 10%.
Operating Limits*
Maximum Applied Pressure: 21 bar (300 psig)
Maximum Free Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 45C
Feedwater pH Range: 3.0 10.0
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater Fouling Index (SDI): 5
Maximum Element Recovery: 20%
Maximum Pressure Drop Per Element: 0.7 bar (10 psi)
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and
membrane life.
Notice: Minimum permeate ow for individual elements 15 % below listed ow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum
sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained
by the application of this information or the safety or suitability of our products,
either alone or in combination with other products. Users are advised to make their
own tests to determine the safety and suitability of each product combination for
their own purposes.



A
B
C
Feed
Concentrate
Permeate
Part Number
MBROYL0700 1.4 (6) 21 (533) 2.4 (61) 0.75 (19.1) 0.9 (2) 1.2 (30.5)
Maximum Feed Flow
m
3
/hr (usgpm)
Dimensions inches (mm)
Weight.
kg (lbs)
Permeate tube length
inches (mm)
A B C
Visit our website:
www.veoliawaterst.com
VWS CATALOGUE /VWSRO-XTLE-2521/AQF106_EN_V1.2 nov10
RO Membranes
VWSRO-XTLE-4021
Extra Low Energy Element
Part Number
Nominal Area
m
Permeate Flow Rate
m
3
/d (usgpd)
Minimum Salt Rejection
(%)
MBROYN0700 3 3.6 (960) 98
Type
Conguration: Spiral Wound
Membrane Polymer: Composite Polyamide/Polysulphone
Test Conditions
500 ppm NaCl solution, 7 bar (100 psi), 25C, pH 6 7, Permeate Recovery 10%.
Operating Limits*
Maximum Applied Pressure: 21 bar (300 psig)
Maximum Free Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 45C
Feedwater pH Range: 3.0 10.0
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater Fouling Index (SDI): 5
Maximum Element Recovery: 20%
Maximum Pressure Drop Per Element: 0.7 bar (10 psi)
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and
membrane life.
Notice: Minimum permeate ow for individual elements 15 % below listed ow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum
sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained
by the application of this information or the safety or suitability of our products,
either alone or in combination with other products. Users are advised to make their
own tests to determine the safety and suitability of each product combination for
their own purposes.



A
B
C
Feed
Concentrate
Permeate
Part Number
MBROYN0700 2.7 (12) 21 (533) 3.95 (100) 0.75 (19.1) 1.8 (4) 1.2 (30.5)
Maximum Feed Flow
m
3
/hr (usgpm)
Dimensions inches (mm)
Weight.
kg (lbs)
Permeate tube length
inches (mm)
A B C
Visit our website:
www.veoliawaterst.com
VWS CATALOGUE /VWSRO-XTLE-4021/AQF105_EN_V1.2 nov10
RO Membranes
VWSRO-XTLE-4040
Extra Low Energy Element
Part Number
MBROYN0704 7.9 9.5 (2500) 99 99.2
Nominal Area
m
Permeate Flow Rate
m
3
/d (usgpd)
Salt Rejection (%)
Minimum Nominal
Type
Conguration: Spiral Wound
Membrane Polymer: Composite Polyamide/Polysulphone
Test Conditions
500 ppm NaCl solution, 7 bar (100 psi), 25C, pH 6 7, Permeate Recovery 15%.
Operating Limits*
Maximum Applied Pressure: 42 bar (600 psig)
Maximum Free Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 45C
Feedwater pH Range: 3.0 10.0
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater Fouling Index (SDI): 5
Maximum Element Recovery: 20%
Maximum Pressure Drop Per Element: 0.7 bar (10 psi)
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and
membrane life.
Notice: Minimum permeate ow for individual elements 15 % below listed ow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum
sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained
by the application of this information or the safety or suitability of our products,
either alone or in combination with other products. Users are advised to make their
own tests to determine the safety and suitability of each product combination for
their own purposes.



A
B
C
Feed
Concentrate
Permeate
Part Number
MBROYN0704 3.6 (16) 40 (1016) 3.95 (100) 0.75 (19.1) 3.6 (8) 1.05 (26.7)
Maximum Feed Flow
m
3
/hr (usgpm)
Dimensions inches (mm)
Weight.
kg (lbs)
Permeate tube length
inches (mm)
A B C
Visit our website:
www.veoliawaterst.com
VWS CATALOGUE /VWSRO-XTLE-4040/AQF104_EN_V1.3 sept11
RO Membranes
VWSRO-LERA-8040
Low Energy Regular Area Element
Part Number
MBROYR0750 37 45.4 (12000) 99.0 99.3
Nominal Area
m
Permeate Flow Rate
m
3
/d (usgpd)
Salt Rejection (%)
Minimum Nominal
Type
Conguration: Spiral Wound
Membrane Polymer: Composite Polyamide/Polysulphone
Test Conditions
1500 ppm NaCl solution, 10.5 bar (150 psi), 25C, pH 6 7, Permeate Recovery 15%.
Operating Limits*
Maximum Applied Pressure: 42 bar (600 psig)
Maximum Free Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 45C
Feedwater pH Range: 3.0 10.0
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater Fouling Index (SDI): 5
Maximum Element Recovery: 20%
Maximum Pressure Drop Per Element: 0.7 bar (10 psi)
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and
membrane life.
Notice: Minimum permeate ow for individual elements 15 % below listed ow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum
sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained
by the application of this information or the safety or suitability of our products,
either alone or in combination with other products. Users are advised to make their
own tests to determine the safety and suitability of each product combination for
their own purposes.



A
B
C
Feed
Concentrate
Permeate
Part Number
MBROYR0750 17 (75) 40 (1016) 7.89 (200) 1.125 (28.6) 16.4 (36)
Maximum Feed Flow
m
3
/hr (usgpm)
Dimensions inches (mm)
Weight.
kg (lbs)
A B C
Visit our website:
www.veoliawaterst.com
VWS CATALOGUE /VWSRO-LERA-8040/AQF110_EN_V1.2 nov10
RO Membranes
VWSRO-SRHA-8040
Standard Rejection High Area
Element
Part Number
MBROYR0754 41 45.4 (12000) 99.5 99.6
Nominal Area
m
Permeate Flow Rate
m
3
/d (usgpd)
Salt Rejection (%)
Minimum Nominal
Type
Conguration: Spiral Wound
Membrane Polymer: Composite Polyamide/Polysulphone
Test Conditions
1500 ppm NaCl solution, 10.5 bar (150 psi), 25C, pH 6 7, Permeate Recovery 15%.
Operating Limits*
Maximum Applied Pressure: 42 bar (600 psig)
Maximum Free Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 45C
Feedwater pH Range: 3.0 10.0
Maximum Feedwater Turbidity: 1.0 NTU
Maximum Feedwater Fouling Index (SDI): 5
Maximum Element Recovery: 20%
Maximum Pressure Drop Per Element: 0.7 bar (10 psi)
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and
membrane life.
Notice: Minimum permeate ow for individual elements 15 % below listed ow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum
sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained
by the application of this information or the safety or suitability of our products,
either alone or in combination with other products. Users are advised to make their
own tests to determine the safety and suitability of each product combination for
their own purposes.



A
B
C
Feed
Concentrate
Permeate
Part Number
MBROYR0754 17 (75) 40 (1016) 7.89 (200) 1.125 (28.6) 16.4 (36)
Maximum Feed Flow
m
3
/hr (usgpm)
Dimensions inches (mm)
Weight.
kg (lbs)
A B C
Visit our website:
www.veoliawaterst.com
VWS CATALOGUE /VWSRO-SRHA-8040/AQF112_EN_V1.2 nov10
Pressure Gauges
Radial or Bottom Connection
Stainless Steel
With Liquid Filling
Features & Benets
Excellent load-cycle stability
and shock resistance
All stainless steel construction
German Lloyd, Gosstandart
and DVGW approval
PART REF. IMPSGG0030
Hygienic/ sanitary type diaphragm
type pressure
Connection 1.5" Tri-clamp
PART REF. IMPSGG1315
Liquid, glycerine lled ; Dampens
out vibrations out which can occur
Ease of reading the pressure
Increased gauge life
PART REF. IMPSGG1360
Liquid, glycerine lled ; Dampens
out vibrations out which can occur
Ease of reading the pressure
Increased gauge life

Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
With liquid-lled case for applications
with high dynamic pressure pulsations
or vibrations

The measurement of pressure


using Bourdon tube type
pressure gauges is important for
monitoring the operation of
water treatment solutions and
also assists with the prediction
of the maintenance requirements.
Scale ranges from 0 to 11 bar
depending the models:
PART REF. IMPSGG0030
from 0 to 7 bar
PART REF. IMPSGG1315
from 0 to 6.8 bar
from 0 to 100 psi
PART REF. IMPSGG1360
from 0 to 11 bar
from 0 to 160 psi

Applications

VWS Monitor
Free Chlorine, Total Chlorine,
Hardness, Carbonate Hardness
Features & Benets
Menu-driven, programmable
functions in clear LCD text display
Programmable hardness unit
in dH, f, ppm CaCO
3
, mmol/l
Accurate titration via
piston-dosing pump
Low maintenance operation
Low reagent and water consumption
Two adjustable limit values with
programmable switch functions
Monitoring of two measuring points
Analysis initiation:
Automatic time set intervals
(0 - 99 minutes)
Dependent on the residual plant
capacity
Quantity-dependent (water meter)
External control
Programmable supplementary program
Output terminal for alarm
(fault messages)
Monitoring of an analysis run and
error messages
Monitoring of the lter capacity
Reagent storage bottle 500ml
for extended operating periods
Analog terminal 0/4-20mA
Available in 3 languages

Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Boiler feed water
Process water
Pharmaceuticals
Food & beverage
Dialysis
Swimming pool water
Drinking water
The VWS Monitor
is the ideal system for water
quality monitoring.
Several models and parameters:
Free chlorine (CLF)
Total chlorine (CLT)
Hardness (TH)
Hardness & Chlorine (THCL)
Carbonate hardness (KH)

Ideal for monitoring water quality:


Applications

Visit our website:


www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /VWS Monitor/AQF122_EN_V1.1
VWS Monitor
Performance
Ordering Information
Specications
Parameter Reagent type dH f ppm CaCO
3
mmol/l mg/l - ppm
CL 2250 A
CL 2250 B 0 - 2.50
CL 2250 C
CL 2250 A 0 - 2.50
CL 2250 B
Water hardness TH 2005 0.05 - 0.50 0.09 - 0.89 0.89 - 8.95 0.01 - 0.09
Water hardness TH 2025 0.25 - 2.50 0.45 - 4.48 4.47 - 44.7 0.04 - 0.45
Water hardness TH 2100 1.0 - 10.0 1.79 - 17,9 17.9 - 179 0.18 - 1.79
Water hardness TH 2250 2.5 - 25.0 4.48 - 44.8 44.8 - 448 0.45 - 4.48
Carbonate hardness TC 2050 0.5 -5.0 0.90 - 8.96 0.18 - 1.79
Carbonate hardness TC 2100 1.0 - 20.0 1.79 - 35.8 0.36 - 7.16
Total chlorine
Free chlorine
Total Chlorine
Carbonate Hardness + Hardness
Hardness + Total Chlorine
Part Number
IEPOHR301087
IEPOGU301092
IEPOGU301091
IEPOGU301089
IEPOGU301090
Model
VWS Monitor KH
VWS Monitor CLF
VWS Monitor CLT
VWS Monitor DUO
VWS Monitor THCL
Measuring Parameter
Carbonate Hardness
Free Chlorine
Power supply
Power consumption
Degree of protection
Protection class
Ambient temperature
Water temperature
Operating pressure
Dimensions (W x H x D)
Weight
230 V or 24 V 10 % ; 50 - 60 Hz
max. 30 VA
IP 65
I ; CE
10 - 45 C
10 - 40 C
0.1 - 8 bar ; 10
4
- 8 x 10
5
Pa
380 x 480 x 280 mm
approx. 10.5 kg
VWS Monitor TH
Hardness
Features & Benets
Menu-driven, programmable
functions in clear LCD text display
Programmable hardness unit
in dH, f, ppm CaCO
3
, mmol/l
Accurate titration via
piston-dosing pump
Low maintenance operation
Low reagent and water consumption
Two adjustable limit values with
programmable switch functions
Analysis initiation:
Automatic time set intervals
(0 - 99 minutes)
Quantity-dependent (water meter)
External analysis STOP
Output terminal for alarm
(fault messages)
Monitoring of an analysis run and
error messages
Reagent storage bottle 500ml
for extended operating periods
Analog terminal 0/4-20mA
Available in 6 languages

Related Services
Local after-sales service and support
teams oer preventative and
corrective maintenance programs
to ensure the long-term, ecient
operation of installed plant.
Boiler feed water
Process water
Pharmaceuticals
Food & beverage
Dialysis
Swimming pool water
Drinking water
The VWS Monitor TH
automatically determines
residual / total water hardness
via titration.
Measuring range: 0.05 -25.0dH

Ideal for monitoring water quality:


Applications

Visit our website:


www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /VWS Monitor/AQF121_EN_V1.1
VWS Monitor TH
Performance
Ordering Information
Specications
Parameter Reagent type dH f ppm CaCO
3
mmol/l mg/l - ppm
Water hardness TH 2005 0.05 - 0.50 0.09 - 0.89 0.89 - 8.95 0.01 - 0.09
Water hardness TH 2025 0.25 - 2.50 0.45 - 4.48 4.47 - 44.7 0.04 - 0.45
Water hardness TH 2100 1.0 - 10.0 1.79 - 17,9 17.9 - 179 0.18 - 1.79
Water hardness TH 2250 2.5 - 25.0 4.48 - 44.8 44.8 - 448 0.45 - 4.48
Measuring parameter
Hardness
Model
VWS Monitor TH
Part Number
IEPOHR301088
Power supply
Power consumption
Degree of protection
Protection class
Ambient temperature
Water temperature
Operating pressure
Dimensions (W x H x D)
Weight
230 V or 24 V 10 % ; 50 - 60 Hz
max. 30 VA
IP 65
I ; CE
10 - 45 C
10 - 40 C
0.1 - 8 bar ; 10
4
- 8 x 10
5
Pa
380 x 480 x 280 mm
approx. 10.5 kg
www.veoliawaterst.com
www.veoliawaterst.com