Sie sind auf Seite 1von 12

FI exi MuI ti radi o BTS

Qui ck Gui de
CabI i ng
Cabl i ng
8
nternal power
cabl i ng
Antenna
cabl i ng
Transmi ssi on
cabl i ng
Opti cal cabl i ng
Check the i nstaI I ati on
nstal l ati on
check l i st
1 1
Front covers
1 0
Front covers
I nstaI I ati on
nstal l i ng the
pl i nth
4
Pl i nth on the
fl oor
Adapter
mechani cs
Pl i nth on the
wal l
Pl i nth on the
pol e
I nstaI I ati on
nstal l i ng the
modul es
7
Pri nci pl e of
modul e
i nstal l ati on
Recommended
i nstal l ati on order
I nstaI I ati on
nstal l i ng the
transmi ssi on
sub-modul e
and power feed
6
nstal l i ng the
transmi ssi on
sub-modul e
DC power cabl e
Thi s gui de can be used as qui ck reference for Fl exi Mul ti radi o BTS i nstal l ati on.
Fl exi Mul ti radi o BTS i s a macro BTS si te sol uti on. t consi sts of one System Modul e wi th
a transmi ssi on sub-modul e and RF Modul es. t can be i nstal l ed stacked on the fl oor,
or mounted on the wal l or on the pol e.
Thi s qui ck gui de i s for basi c stand-al one i nstal l ati on onl y. For other i nstal l ati on opti ons, see operati ng
documentati on.
Ground
the BTS
Groundi ng
pri nci pl e
5
Groundi ng
pri nci pl e of
the BTS
Check the deI i very
1
Contents of
del i very
Prepari ng
modul es for
i nstal l ati on
Back cover
and cabl e
entri es
Prepare the
i nstaI I ati on
3 2
Cl earances
Check the si te
Mi ni mum
cl earances
Poweri ng up and
commi ssi oni ng
the BTS
9
Power up and
commi ssi on BTS
Warni ng
nvi si bl e l aser radi ati on from the modul e opti cal fi bre connector.
Al ways swi tch off the l aser before detachi ng the opti cal fi bre from the connector.
Cauti on
ncorrect cabl es and seal s may not provi de secured weather protecti on. n outdoor
i nstal l ati ons, i ncl udi ng the outdoor cabi net, use onl y tested P55 cl ass outdoor cabl es
wi th seal s provi ded by Noki a Si emens Networks. Thi s i s al so recommended for i ndoor
i nstal l ati ons.
El ectrostati c di scharge (ESD) may damage the modul es. Wear an ESD wri st strap or
use a correspondi ng method when handl i ng the modul es.
The pl i nth rear stopper i s fragi l e. Do not attempt to l i ft the pl i nth usi ng the rear stopper.
The i nformati on i n thi s document i s subj ect to change wi thout noti ce and descri bes onl y the
product defi ned i n the i ntroducti on of thi s documentati on. Thi s document i s not an offi ci al
customer document and Noki a Si emens Networks does not take responsi bi l i ty for any errors or
omi ssi ons i n thi s document. Thi s document i s i ntended for the use of Noki a Si emens Networks
customers onl y for the purposes of the agreement under whi ch the document i s submi tted. No
part of thi s documentati on may be used, reproduced, modi fi ed or transmi tted i n any form or
means wi thout the pri or wri tten permi ssi on of Noki a Si emens Networks. The documentati on has
been prepared to be used by professi onal and properl y trai ned personnel , and the customer
assumes ful l responsi bi l i ty when usi ng i t. Noki a Si emens Networks wel comes customer
comments as part of the process of conti nuous devel opment and i mprovement of the
documentati on.
The i nformati on or statements gi ven i n thi s documentati on concerni ng the sui tabi l i ty, capaci ty or
performance of the menti oned hardware or software products are gi ven "as i s and al l l i abi l i ty
ari si ng i n connecti on wi th such hardware or software products shal l be defi ned concl usi vel y and
fi nal l y i n a separate agreement between Noki a Si emens Networks and the customer.
N NO EVENT W LL Noki a Si emens Networks BE L ABLE FOR ERRORS N TH S
DOCUMENTAT ON OR FOR ANY DAMAGES, NCLUD NG BUT NOT L M TED TO SPEC AL,
D RECT, ND RECT, NC DENTAL OR CONSEQUENT AL OR ANY LOSSES SUCH AS BUT
NOT L M TED TO LOSS OF PROF T, REVENUE, BUS NESS NTERRUPT ON, BUS NESS
OPPORTUN TY OR DATA, that mi ght ari se from the use of thi s document or the i nformati on i n i t.
THE CONTENTS OF TH S DOCUMENT ARE PROV DED "AS S". EXCEPT AS REQU RED
BY APPL CABLE MANDATORY LAW, NO WARRANT ES OF ANY K ND, E THER EXPRESS
OR MPL ED, NCLUD NG, BUT NOT L M TED TO, THE MPL ED WARRANT ES OF
MERCHANTAB L TY, F TNESS FOR A PART CULAR PURPOSE AND NON- NFR NGEMENT,
ARE MADE N RELAT ON TO THE ACCURACY, REL AB L TY OR CONTENTS OF TH S
DOCUMENT. NOK A S EMENS NETWORKS RESERVES THE R GHT TO REV SE TH S
DOCUMENT OR W THDRAW T AT ANY T ME W THOUT PR OR NOT CE.
Thi s document and the product i t descri bes are consi dered protected by copyri ghts and other
i ntel l ectual property ri ghts accordi ng to the appl i cabl e l aws.
The wave l ogo i s a trademark of Noki a Si emens Networks Oy. Noki a i s a regi stered trademark of
Noki a Corporati on. Si emens i s a regi stered trademark of Si emens AG.
Other product names menti oned i n thi s document may be trademarks of thei r respecti ve owners,
and they are menti oned for i denti fi cati on purposes onl y.
Copyri ght Noki a Si emens Networks 201 0. Al l ri ghts reserved.
DN0951 796 versi on 01
-2-
Del i veri es are compl ete.
Equi pment i s not damaged.
Contents of deI i very 1
Check I i st
-3-
System Modul e del i very
DeI i very Contents Versi ons Codes
System Modul e wi th casi ng FSMB 3 FSPA
ESD wri st strap
2 x M5 screws, 4 x K30 screws
RF Modul e del i very FR A 1 . 7/2. 1 GHz Dual 50 W
FR B 1 . 7/2. 1 GHz Si ngl e 50 W
RF Modul e wi th casi ng
Pl i nth del i very Mounti ng ki t for fl oor, wal l and pol e FMFA
Covers del i very 3U front and back covers FMCA
Pol e mounti ng ki t del i very VMPB
470036A
471 000A
471 21 5A
4701 49A
470239A
469978A Mounti ng brackets
OptionaI i tems
Groundi ng cabl e
2 x fi xi ng pl ates for the casi ng
1 2 x M5x8 screws, 2 x M5x1 2 screws, 2 x M8 screws
99481 5A
FTPB wi th 8 x rubber pl ugs, 4 screws, 1 x FCM-FTM connector card , Transmi ssi on sub-modul e
del i veri es FTEB wi th 8 x rubber pl ugs, 4 screws

1 x FCM-FTM connector card, 8 x groundi ng i sol ators
FTFA wi th 2 x metal caps, 4 x screws, 1 x FCM-FTM connector card
FT A wi th 7 x rubber pl ugs, 4 x screws, 1 x FCM-FTM connector card
FTJA wi th 7 x rubber pl ugs, 4 x screws, 1 x FCM-FTM connector card
FTOA wi th 1 x rubber pl ug, 4 x screws, 1 x FCM-FTM connector card
1 x SDH SFP transcei ver
2 x cabl e cl amps
Stress rel i ef pl ate for the power cabl e
20 x cabl e ti es
FRGC 21 00 MHz Dual 50 W
FRGD 21 00 MHz Si ngl e 50 W
471 231 A
471 232A
2 x M5 screws
Opti cal cabl e
Opti cal transcei ver
Power cabl e
994807A
994808A
FRCA 850 MHz Dual 50 W
FRCB 850 MHz Si ngl e 50 W
FRDA 900 MHz Dual 50 W
FRDB 900 MHz Si ngl e 50 W
FRFA 1 900 MHz Dual 50 W
FRFB 1 900 MHz Si ngl e 50 W
471 266A
471 268A
471 265A
471 267A
471 273A
471 01 7A
4807528
1 0 x cabl e ti es
2 x mai ntenance straps
4701 37A
4701 56A
4701 34A
471 025A
4701 33A
471 248A
Transmi ssi on cabl e
del i veri es
FTCA OD cabl e RJ48C - TQ-M/0 1 20ohm 5 m 47031 2A
FTCB OD cabl e RJ48C 1 20ohm 1 5 m 470309A
FTCD OD cabl e SMB-F/0 -BT43-F/0 75ohm 5 m 47031 3A
FTCE OD cabl e SMB-F/0 75ohm 1 5 m 47031 0A
FTCH OD cabl e LC SM 1 31 0 1 5 m 47031 1 A
FTCJ OD cabl e TNC-F7O-TNC M7O 50 ohm 2. 5 m 471 391 A
FTCR OD cabl e RJ45 CAT5E 1 5 m 471 408A
FTCV OD cabl e RJ48C 1 20ohm 30M 471 71 3A
FTCX OD cabl e RJ48C 1 20ohm 50M 471 71 4A
FTCF OD cabl e SMB-F/0 75ohm 30M 471 71 5A
FTCG OD cabl e SMB-F/0 75ohm 50M
471 71 6A
FTCS OD cabl e RJ45 CAT5E 30M 471 71 7A
FTCT OD cabl e RJ45 CAT5E 50M 471 71 8A
4 x M1 0x1 20 bol ts, 4 x M8x25 bol ts, 4x M1 0x200 bol ts,
4 x M1 0x300 bol ts, 4 x washers
FSEB
FSEC
FPKA
FSEB del i very Fl exi System External Al arm, 1 x D37 cabl e assembl y, 3 x cabl e ti es
471 421 A
FSEC del i very
Fl exi System External OVP
471 397A
FPKA del i very
Fl exi Pol e Ki t
471 649A
FRGJ 21 00 MHz Dual 50 W 471 820A
FRGK 21 00 MHz Si ngl e 50 W
FRGM 21 00 MHz Si ngl e 50 W
FRGL 21 00 MHz Dual 50 W
471 821 A
471 834A
471 835A
FSMC 1 FSPC
FSMD 2 FSPC
471 401 A
471 402A
Remote Radi o Head del i very Remote Radi o Head FRGG 21 00 MHz 471 882A
FRGF 21 00 MHz 3-sector
471 483A
FTHA wi th 2 x rubber pl ugs, 4 x screws, 1 x FCM-FTM connector card 471 522A
FT B wi th 7x rubber pl ugs, 4x screws, 1 x FCM-FTM connector card
471 720A
FTCP OD cabl e MDR-68 1 00ohm 30M 471 548A
FP A del i very
Fl exi Pol e nstal l ati on Ki t FP A 471 767A
FRKA 1 500 MHz 3-sector
4721 1 1 A
FTFB wi th 3x metal caps, 2x rubber pl ugs, 4x screws, 1 xFCM-FTM connector card
FTLB wi th 7x rubber pl ugs, 4x screws, 1 xFCM-FTM connector card
FRGP 21 00 MHz 3-sector
FR E 1 . 7/2. 1 GHz 3-sector
FXDA 900 MHz 3-sector
FXCA 850 MHz 3-sector
FXEA 1 800 MHz 3-sector
FRGR 21 00 MHz 1 -sector
4721 00A
471 895A
472083A
4721 42A
472084A
472251 A
FRGQ 2TX 21 00 472261 A
FHDA 2TX 900
FRHA 2600 MHz 3-sector
FRMA 800EU MHz 3-sector
471 894A
472221 A
2 x external cabl e entri es 08501 5A
FR F 2TX 1 . 7/2. 1
FRMB 2TX 800EU
472260A
FSME 2 FSPC 471 469A
471 984A
472036A
4721 67A
472291 A
CI earances 2
Si te meets the mi ni mum cl earances.
Check I i st
Prepari ng moduI es for i nstaI I ati on 3
Back cover and cabI e entri es
1 . Thread the l onger l oop of the
mai ntenance strap around the gri l l ri b.
2. Route the end wi th the snap hook through
the exposed l oop and ti ghten the l oop.
3. Engage the snap hook to the casi ng
usi ng the fi xi ng poi nts.
4. nstal l the back cover i n the rear
of the modul e.
5. Fi x the back cover screws (Torx T25)
and ti ghten to 2. 5 Nm.
6. Fi x the external cabl e entri es
to the si des of the casi ng.
5
Cabl e entri es and back covers are i nstal l ed.
Check I i st
Mi ni mum cI earances
mi n 1 00 mm
(3. 9 i n)
-4-
mi n 75 mm
(3. 0 i n)
mi n 600 mm
( 23. 6 i n)
1
mi n 40 mm (1 . 6 i n) measured
from back cover
(needed for fresh ai r)
mi n 80 mm (3. 1 i n)
measured from pl i nth
6
1 . Check the cl earances around
the pl i nth.
2. Turn the rear stopper.
3. Pl ace the pl i nth on the fl oor,
groundi ng poi nts faci ng
forward.
4. Bol t on the fl oor wi th 4 bol ts,
1 2 mm i n di ameter.
I nstaI I i ng the pI i nth 4
PI i nth on the fI oor
Rear
stopper
Fan mai ntenance
space
305 mm (1 2 i n)
Pl i nth
3
6
0

m
m
(
1
4
.
1

i
n
)
300 mm
(1 1 . 8 i n)
Faci l i ty wal l
1 3. 5 mm
(0. 5 i n)
(4 pcs)
75 mm
(3. 0 i n)
75 mm
(3. 0 i n)
1 . Fi x the upper brackets on the pl i nth wi th 3 screws.
Secure the screws wi th thread l ocki ng compound.
2. Fi x the l ower bracket on the pl i nth wi th 3 screws,
do not ti ghten yet. Secure the screws wi th thread
l ocki ng compound (for exampl e Locti te 243).
When the screws are l eft l oose at thi s poi nt, i t
al l ows the pl i nth to move sl i ghtl y and prevents
i t to get twi sted i n the i nstal l ati on phase.
The brackets of the adapter mechani cs are
i nstaI I ed on the pI i nth i n waI I and poI e
i nstaI I ati ons. They are onI y used wi th FMFA
versi on 1 03 or oI der. I n FMFA versi on 1 04,
the adapter mechani cs have been i ntegrated
to the pI i nth.
NOTE:
Adapter mechani cs
PI i nth on the waI I
1 . Mark screw l ocati ons accordi ng
to the hol es i n adapter
mechani cs and dri l l hol es.
2. Fi x the mounti ng screws on the
wal l and mount the pl i nth.
3. Ti ghten the upper mounti ng
screws.
4. nsert the l ower mounti ng screws.
5. Ti ghten the l ower mounti ng
screws.
6. Ti ghten the adapter mechani cs
screws (FMFA v. 1 03 or ol der onl y).
7. Ground the pl i nth. See
secti on 4 for i nstructi ons.
Bottom
1
2
TIP: I t i s recommended to i nstaI I
the pI i nth wi th the front paneI
faci ng ri ght.
1 0 Nm
The di mensi ons are measured
from the fi xi ng poi nts.
1 85 mm
4
8
2
.
5

m
m

6
0
0

m
m

1
FMFA v. 1 03 or ol der:
ti ghten the screws
6
-5-
2
3
4
5
I nstaI I i ng the pI i nth (conti nued) 4
PI i nth on the poI e
1 . Fi x the upper bracket on the pol e
and attach the mounti ng screws.
The mi ni mum di ameter of the pol e
i s 60 mm and maxi mum 300 mm.
2. Fi x one hal f of the l ower bracket on
the pl i nth (FMFA v. 1 03 or ol der:
on the adapter mechani cs).
3. Li ft the pl i nth on the pol e.
4. Ti ghten the mounti ng screws.
5. Fi x the counterpart of the l ower
bracket on the pol e.
6. FMFA v. 1 03 or ol der: ti ghten
the adapter mechani cs screws.
7. f a second pl i nth i s requi red, i nstal l
i t on the other si de of the pol e
mounti ng bracket.
8. Ground the pl i nth. See secti on 4 for
i nstructi ons.
1
2
Secure the
screws wi th
thread
l ocki ng
compound.
5
6
Ti ghten
the screws
5
7
8

m
m
(
2
2
.
8

i
n
.
)
7
I nstaI I i ng the pI i nth (conti nued) 4
Adapter mechani cs are i nstal l ed, secured wi th thread l ocki ng compound (for exampl e Locti te 243) and
ti ghtened (for wal l and pol e i nstal l ati on).
Pl i nth i s i nstal l ed accordi ng to i nstructi ons.
Pl i nth i s l evel and does not get twi sted.
Pl i nth i s grounded.
Check I i st
I nstaI I i ng the transmi ssi on sub-moduI e
and power feed
6
InstaI I i ng the transmi ssi on sub-moduI e
3
6
Transmi ssi on sub-modul e i s properl y i nstal l ed.
Check I i st
1 . Loosen the System Modul e core fi xi ng screws.
2. Pul l out the modul e core.
3. Remove the rubber pl ug.
4. nsert the FCM-FTM connecti on card.
5. Check that the FCM-FTM connecti on card i s strai ght.
6. nsert the transmi ssi on sub-modul e.
7. Fi x the screws careful l y. Ti ghten to 4. 0 Nm.
2
4
8. f usi ng the FT A, FT B, FTJA, FTOA or FTLB do one of the fol l owi ng:
FT A/FT B/FTLB: nsert a SFP Ethernet transcei ver i nto the GE sl ot.
FTJA: nsert the SFP transcei ver i nto the E F1 sl ot.
FTOA: nsert the SFP SDH transcei ver to the FTOA.
NOTE: If your transmi ssi on sub-moduI e i s the FTIA,
FTIB, FTJA or FTLB, the opti caI GE SFP i s onI y requi red i f
thi s i nterface i s used. The standard i nterface i s the
FE i nterface.
FTJA
7
FT A/FT B/FTLB
FTOA
-6-
Groundi ng pri nci pI e of the BTS
5
1 . Ground the pl i nth to the si te mai n ground.
2. Connect the wri st strap.
3. nstal l the fi rst modul e.
4. Connect the groundi ng cabl e to the modul e
front panel .
5. Route the groundi ng cabl e through the cabl e
entry.
6. Connect the other end of the cabl e to the pl i nth.
7. Repeat steps 3-6 for each modul e.
8. Fi x the excess cabl es to the cabl e support pl ates
wi th cabl e ti es.
Groundi ng pri nci pI e
Anti stati c wri st strap i s used when handl i ng modul es.
Modul e core i s i nsi de the casi ng.
Al l modul es are grounded.
Check I i st
NOTE: Do not chai n groundi ng cabI es.
Wri st strap
1
6
5
4
2
si te mai n
groundi ng
*
*
External cabl e
entry
I nstaI I i ng the moduI es 7
1 . Li ne up the l ocati ng marks on the si de of the modul e and
al i gn the hol es on the fi rst modul e bottom wi th the fi xi ng
studs on the pl i nth.
2. Push the modul e back unti l i t stops.
3. Fi x wi th two screws. n pol e and wal l i nstal l ati ons, secure the
screws wi th thread l ocki ng compound.
4. Connect the groundi ng cabl e to the modul e and the pl i nth.
5. nsert the second modul e and repeat steps 1 -4.
6. Repeat the steps above for each modul e i n your
confi gurati on.
Pri nci pI e of moduI e i nstaI I ati on
NOTE: I n poI e and waI I i nstaI I ati ons, attach the fi xi ng pI ate
across the moduI e casi ngs and fi x wi th si x screws. Secure
the screws wi th thread I ocki ng compound.
See product documentati on for further i nformati on.
DC power cabI e
I nstaI I i ng the transmi ssi on sub-moduI e
and power feed (conti nued)
6
Make sure that the DC connector P gasket i s i n pl ace.
Check I i st
DC power cabl e i s connected and the cabl e cl amp i s i n pl ace.
Modul e core i s i nsi de the casi ng, and cabl e entri es are i nstal l ed.
bl ue - bl ack +
NOTE: When i nstaI I i ng moduI es i nto a thi rd-party cabi net,
moduI e casi ngs must aI ways be used. Si de trays or pI ates
are requi red under each moduI e i n a thi rd-party cabi net.
See operati ng documentati on for further i nformati on.
1 . Route the DC power cabl e through the cabl e entry.
2. nstal l the cabl e cl amp on the vacant groundi ng poi nt of
the modul e.
3. Route the cabl e through the cabl e cl amp.
4. Remove the power connector P gasket.
5. Thread the DC cabl e through the P gasket.
6. nsert the DC power cabl e to the connector and
make sure that the pol ari ty i s correct.
7. Ti ghten the connecti ons to 5. 0 Nm. Do not overti ghten.
8. Cover the connector wi th the P gasket and fi x the cabl e
to the cabl e ti e poi nt wi th a cabl e ti e.
9. Ti ghten the cabl e cl amp.
1 0. Re-i nsert the modul e core to the casi ng.
1 1 . Ti ghten the modul e core screws.
1 2. nstal l the cabl e entri es and ti ghten the screws.
NOTE:
Do not swi tch on the si te DC power feed yet.
3
4
2
1
9
1 0
5
7
6
8
1 1
1 2
-7-
5
5
1
2
3
5
Recommended i nstaI I ati on order
Modul es are properl y stacked.
Modul es are l evel .
Modul es are grounded.
Modul e fi xi ng screws are secured wi th thread l ocki ng compound and ti ghtened.
Check I i st
I nstaI I i ng the moduI es (conti nued) 7
-8-
RF Modul e
RF Modul e
System Modul e
RF Modul e
Power Modul e
(opti onal )
Pl i nth
RF Modul e
System
Modul e
Power Modul e
(opti onal )
Pl i nth
RF Modul e
Pl i nth
Pol e
RF Modul e
NOTE: Max. 5 moduI es for earthquake zone 4.
Max. 9 moduI es for earthquake zone 2.
Extensi on System
Modul e (opti onal )
RF Modul e
System Modul e
Power Modul e
(opti onal )
RF Modul e
RF Modul e
Pl i nth
Wal l
NOTE: Maxi mum 2 moduI es
per pI i nth.
NOTE:
Maxi mum 2 moduI es per pI i nth.
CabI i ng 8
Antenna cabI i ng
1 . Remove the seal from the antenna
connector i n the RF Modul e.
2. Push the antenna j umper cabl e to the
RF Modul e antenna connector.
3. Pi erce the cabl e entry hol e wi th a kni fe.
4. Push the antenna j umper cabl e to the
cabl e entry.
5. Ti ghten the connector to 25 Nm.
6. Repeat for al l the antenna cabl es
i n the confi gurati on.
InternaI power cabI i ng
3
2
NOTE: I n waI I and poI e i nstaI I ati ons,
the recommended cabI e routi ng i s
through the I ower cabI e entry.
1 . Remove the i nternal cabl e entry cover
(Dual or Si ngl e RF Modul e onl y).
2. Remove connector seal s from power
cabl e connectors i n modul es.
3. nstal l the DC cabl e connector properl y to
the System Modul e.
4. Push the connector seal fi rmI y i n pI ace.
5. Route the cabl e through the i nternal cabl e
entry between System and RF Modul es
(Dual or Si ngl e RF Modul e onl y).
6. Connect the DC power cabl e to
the RF Modul e.
7. Push the connector seal fi rml y i n pl ace.
8. Coi l up the excess cabl e and do one
of the fol l owi ng:
- Dual or Si ngl e RF Modul e: push the cabl e
i n the RF Modul e cabl e sl ot
- 3-sector RF Modul e: Fi x the cabl e to the
support pl ate on the casi ng wi th cabl e ti es
9. Repeat for al l RF Modul es i n the
confi gurati on.
1 0. Make sure that al l the connector seal s
are properI y i nstaI I ed.
5
4
Cabl e entri es are not used
i n cabi net i nstal l ati ons
4
3
2
1
Cabl i ng i n 3-sector RF Modul e
6
8
8
6
-9-
8
6
Cabl i ng i n Dual or
Si ngl e RF Modul e
Cabl i ng i n 3-sector
RF Modul e
8
6
1
Opti caI cabI i ng
CabI i ng (conti nued)
8
1 . Remove the connector seal from the
opti cal cabl e connector i n the modul es.
2. Push the opti cal transcei ver i n the
System Modul e and remove the P
protecti ve cap from the transcei ver.
CAUTION: The opti caI cabI es are factory-bended to the I eft
and, when connected, must aI ways be routed to the I eft from
the connector. Bendi ng them to the ri ght by force wi I I break
the cabI es.
3. Pul l back the connector seal to uncover
the connector.
4. Remove the protecti ve pl ugs, cI ean the
connector endfaces (see operati ng
documentati on) and connect the cabl e
to the System Modul e.
Make sure i t cl i cks i nto pl ace.

5. Push the connector seal fi rmI y i n pI ace.
7. Coi l up the excess cabl e and push i t i n
the RF Modul e cabl e sl ot (Dual or Si ngl e RF
Modul e onl y).
8. Push the opti cal transcei ver i n the RF
Modul e and remove the P protecti ve
cap from the transcei ver.
9. Remove the protecti ve pl ugs, cl ean the
connectors and connect the opti cal cabl e
to the RF Modul e. Make sure i t cl i cks
i nto pl ace.
1 0. Push the connector seal fi rmI y i n pI ace.
6. Route the cabl e between System and
RF Modul es as fol l ows:
- Dual or Si ngl e RF Modul e: use the
i nternal cabl e entry.
- 3-sector RF Modul e: use an external cabl e
entry and fi x the cabl e to a cabl e support
pl ate.
1 1 . Repeat for al l RF Modul es i n the
confi gurati on.
1 2. Make sure that al l connector seal s are
properI y i nstaI I ed.
TIP: If necessary, the opti caI cabI es can aI so be routed
through the externaI cabI e entri es. In that case, make a I oop
of the excess cabI e and fi x i t to the cabI e support pI ates wi th
cabI e ti es.
5
1
Transmi ssi on cabI i ng
2
1
5
4
3
6. Make sure that al l the connector seal s
are properI y i nstaI I ed.
8. Repeat for al l transmi ssi on cabl es i n
the confi gurati on.
1 . Remove the connector seal from the
transmi ssi on sub-modul e connector.
2. Route the transmi ssi on cabl e
through the cabl e entry.
3. Pul l back the connector seal to
uncover the connector.
4. Connect the cabl e to the
transmi ssi on sub-modul e.
5. Push the cabl e connector seal
fi rmI y i n pI ace.
CAUTION: Do not bend opti caI cabI es beyond the mi ni mum
radi us of 70 mm.
NOTE:
If usi ng the FTOA or FTLB or the opti caI GE opti on of FTIA/FTIB/FTJA, an opti caI fi bre i s requi red.
If usi ng the FTFA or FTFB, i t i s recommended to use the FI exbus j umper cabI e FTCJ 471 391 A for each
FI exbus i nterface.
6
7. Fi x the cabl es wi th the cabl e ti es on the
cabl e entry or cabl e support pl ate.
-1 0-
Cabl i ng i n Dual or Si ngl e
RF Modul e
Cabl i ng i n 3-sector RF Modul e
6
CAUTION: Make sure that the opti caI
cabI e connectors have been cI eaned.
4
3
2
Cl ean wi th swab or
wi pe and al cohol .
Left si de
7
Check I i st
Front covers
1 0
Front covers
1 . Thread the l onger l oop
of the mai ntenance strap
through the hol e on
the front cover.
2. Route the end wi th
the snap hook through
the exposed l oop
and ti ghten the l oop.
3. Engage the hook to
the hol e on the external
cabl e entry.
4. nstal l the front cover
and ti ghten the screws
(Torx 25) to 2. 5 Nm.
Poweri ng up and commi ssi oni ng the BTS 9
1 . Power up the BTS and check the LEDs and fuses to ensure that al l modul es are powered.
2. Commi ssi on the BTS. See the Commissioning Flexi Multiradio BTS document for further i nformati on.

1
Al l cabl es are connected accordi ng to the confi gurati on.
Opti cal cabl e connectors have been cl eaned.
BTS external cabl es or cabl es between the modul es on separate pl i nths are routed vi a
external cabl e entri es.
Connector seal s are fi rmI y i n pI ace.
Al l cabl es are ti ed wi th cabl e ti es or routed through cabl e cl amps.
Check I i st
4
4
Modul e front panel covers are i nstal l ed.
-1 1 -
I nstaI I ati on check I i st 1 1
Perform these checks to make sure that the i nstaI I ati on i s compI ete:
Del i very i s compl ete and undamaged.
Mi ni mum cl earances are met.
Pl i nth i s i nstal l ed accordi ng to the i nstructi ons.
FMFA v. 1 03 or ol der: Adapter mechani cs are i nstal l ed (for wal l and pol e i nstal l ati ons).
Modul es are i nstal l ed accordi ng to the i nstructi ons.
Power suppl y cabl e i s connected.
Cabl e entri es are i nstal l ed.
Antenna cabl es are connected accordi ng to the confi gurati on.
nternal power cabl es are connected.
Opti cal fi bre cabl e connectors are cl eaned and connected.
Transmi ssi on cabl es are connected.
Cabl es between the modul es on the same pl i nth are routed vi a i nternal cabl e entri es.
Transmi ssi on sub-modul e i s i nstal l ed accordi ng to the i nstructi ons.
BTS external cabl es or cabl es between the modul es on separate pl i nths are routed
vi a external cabl e entri es.
Cabl e connector seal s are fi rmI y i n pI ace.
Modul e front covers are i nstal l ed.
Pl i nth i s grounded.
Modul es are grounded to the pl i nth.
BTS i s swi tched on and al l modul es are ready for commi ssi oni ng.
Si te i s cl ean and i nstal l ati on compl eted.
Unused connectors are covered wi th P seal s.
Cabl es are ti ed properl y.
-1 2-