Sie sind auf Seite 1von 2

IS 3370-Pt 1.

Table 1 :
Min. conc grade M30, min. cement content = 320 kg/m3, max. w/c = 0.45
Min. conc grade M25 for tank capacity < 50m3.
Nominal Clear Cover :
Exposure (as
per
T-3, IS 456)
Clr cover (mm)
Min. Conc.
Grade

Mild &
Moderate

Severe

Very severe

Extreme

30
M30

45
M30
Prefer-M35

50
M35
Prefer-M40

75
M40
Prefer-M45

UG Tank : Design for combinations incl. Earth Pr. & Water Pr. independently.
For Uplift FoS =1.20 for Stability check
Curing Period = 14 days. The rate for first time fill 1m per 24 hrs.

IS 3370-Pt 2.
Limit State Design :
LSM : max. crack width = 0.2mm, No redistribution of bending moment.
If the steel service stress in tension < 130 MPa (Fe 415), crack width deemed to be satisfied.
Working Stress Method :
Allowable Stress in Steel : Fe 415 Tension 130 MPa , comp, 140 MPa
Allowable Stress in Conc.: (Max. Shear Stress as per IS 456)
Conc. Grade
Direct Tension (MPa)
Bending Tension (MPa)
Direct Comp. (MPa)
Bending Tension (MPa)

M25
1.3
1.8
6.0
8.5

M30
1.5
2.0
8.0
10

M35
1.6
2.2
9.0
11.5

M40
1.8
2.4
10.0
13

Min. Reinf. (cl. 8.1.1) : Fe 415 Grade steel


1. Surface Reinf. In Walls & suspended Slab
0.35% of the surface zone in each direction
Surface zone = D ( for D < 200) : As = 3.5xD mm2/m, in each direction on one face
= 200 < D < 500 : 1.75xD mm2/m, in each direction at each face.
= 250 Each Face (For D > 500), 438mm2/m each direction, each face
If any dimension is < 15m, the min. reinf. is reduced to 0.24 %

2. Surface Reinf. for slab on ground :


0.35% of the surface zone in each direction
Surface zone = D/2 ( for D < 300) : As = 1.75xD mm2/m, in each direction on upper face
= Upper D/2, Lower 100 for 300 < D < 500 :
:Upper face 1.75xD mm2/m, on each direction
Lower face 350 mm2/m in each direction
= Upper 250, Lower 100 for D > 500:
Upper face 875 mm2/m, on each direction
Lower face 350 mm2/m in each direction on each face.

App-A : Min. Reinf. For Crack Control for Temperature & Moisture.
c = fct/fy : fct = Direct tensile strength of immature conc.
Conc. Grade
fct (Mpa)
c (%)

M25
1.15
0.28

M30
1.30
0.31

M35
1.45
0.35

M40
1.60
0.39

Slab on Ground : D <200 provide as %c x 1000 mm2/m, (100mm basis)


200<D<500, provide (%c x D/2 basis) i.e. %c x D/2*10 mm2/m,
D>500 top based on 250mm (%c x 25 mm2/m)
Bottom based on 100mm (%c x 10 mm2/m), (D, mm unit)
FOR IMMATURE CONCRETE:

= 1/3 x /Smax,
Smax = (36363)/(T1+T2) for max. crack width 0.2mm, = 0.000011
Take T1 = 30 for summer, 20 for winter (add 10 for thick member with D>500)
Provide contraction joints at 15m and T2=0.
For T= 30
Dia
(%)

= 10
= 0.275

12

16

0.330

0.440

20
0.55

Refer Table 3 of the code for Permissible Shear Stress.

==================================================

Das könnte Ihnen auch gefallen