Sie sind auf Seite 1von 8

Ref: CGMEPL/WBPDCL-SDTPP/00371/13-14

M/S. SAGARDIGHI THERMAL POWER PROJECTS, WEST BENGAL POWER DEVELOPMENT CORPORATION LTD, SAGARDIGHI, WEST BENGAL
Kind Attn : Mr. RAM PRASAD SARKAR (ASST MANAGER)

Date:14-08-2013

SUB: SUPPLY OF effen MAKE ENERGY EFFICIENT FRP FAN FOR YOUR EXHAUST FAN TO ACHIEVE 25% (5%) ENERGY SAVING. Dear Sir,

Thank you very much for your interest regarding energy efficient FRP Fan during discussion with undersigned recently.

In reference to the above, we are pleased to submit our offer for the supply of effen make energy efficient FRP Fan for your EXHAUST FAN as per enclosed technical annexure and commercial terms & conditions.

We hope you will find our offer in line with your requirement and look forward to receiving your valued order that we are able to prove our claim. In case, you need please do not hesitate to contact us. any further clarifications,

Thanking and assuring you of our best services at all times. Yours faithfully, For, CGM Equipments (P) Ltd,

SUMAN CHATTERJEE (Managing Director) Encl.: a/a

EXECUTIVE SUMMARY CGM EQUIPMENTS PRIVATE LIMITED recognized as Indias one of the large private sector energy conservation company, with a reputation for trustworthiness. CGM surges ahead into yet another year with plans of sustained growth, greater value to consumer and reliable products and services. The effen fan is designed for industrial cooling tower applications, offering distinct advantages over other fan designs. The effen blade enhancement provides increased performance overcoming tip clearance lossesaiding the movement of air next to the fan cylinder. The wide blade design is well suited for low noise operation, delivering superior air flow and pressure capability at reduced speed. The High Performance effen airfoil is one of the most efficient in the industry today. A nylon leading edge erosion barrier is molded into each blade to insure long service life. The hollow blade is designed with a deep section airfoil making the effen strong, yet light and easy to handle. Constructed of fiberglass reinforced epoxy in one continuous piece, with a consistent moment weight, effen blades are interchangeable without the need to rebalance the fan assembly. Each blade is gripped between two machined clamps for attachment between dual hub plates. By loosening the attachment hardware, blades are easily rotated to achieve desired pitch delivering precise utilization of fan horsepower. Superior strength, excellent quality, light weight, outstanding performance make the Marley effen the fan of choice for todays axial flow operations. Energy conservation is the prime aim of any Industry. The fans are number one user of power in axial flow operation. Though there are number of means to reduce power consumption in a Industry, one method is to use hollow FRP blades. The objective is to select & use proper advanced aerofoil designed hollow FRP blades to have substantial energy saving. The energy consumption of axial flow effen make FRP fans having hollow FRP blades with Aluminum diecasting hot dip galvanized hub. It will focus how & how much a user can reduce the operating cost of a axial flow operation by use of hollow FRP blades & simultaneously with designed or increase in airflow i.e. increase in efficiency of axial flow operation. The specific practical benefits are mentioned in table form hereunder. DETAILS Make of the existing metallic fan Proposed energy efficient fan Diameter of the fan Motor power Total no of fans (No) Investment in 03 nos fan in Rs. Monetary saving in Rs. Return on Investment in months BENEFITS EXHAUST FAN CGMEPL make effen FRP fan

450 MM 0.75 KW 03 NOS 33,750.00 21,840.00 18

TECHNICAL SPECIFICATION FOR COOLING TOWER Parameters Design Basis Fans Type Quantity Diameter No. of Blades Nos. mm Nos. Axial Flow 03 450 3/4 Units Specifications

Motors Make Rated HP per cell Synchronous Speed Current Characteristics KW RPM CG 0.75 1410 415V / 50Hz / 3

PHYSICAL DATA SHEET-450 MM DIMENSIONS FAN DIAMETER HUB DIAMETER BLADES / SET FAN EFFICIENCY AIRFLOW MOTOR POWER STALL POINT AIRFOIL MODEL BLADE WEIGHT (aprox) TOTAL WEIGHT (aprox) MATERIAL OF CONSTRUCTIONS MATERIAL FAN BLADE HUB PLATE HARDWARE TYPE OF HUB COATING BALANCING FAN ASSEMBLY Adge Protection: Fan Blades are individually momentum balanced and complete rotor statically balanced. Special laminates with epoxy resin used for edge protection. FRP AL SS SINGLE Plate POLYPAX 0.500 5 AS EXISTING AS EXISTING 23 Aerodynamic VALUE 450 100-150 03/04 90 % M/S KW / RPM AEROFOIL UNIT mm mm NOS

EFFEN-1.5 KGS KGS

GRADE/SPEC FRP Epoxy Composite AL 304

Our service Engineer will be conducting the Performance Test of your existing metallic / GRP fan and our FRP fan in presence of your officials and shall be measuring the following parameters. 1. 2. 3. AIR FLOW, BLADE ANGLE AND RPM, POWER CONSUMPTION AT MOTOR TERMINALS.

The above performance test will be carried out as per C.T.I. (U.S.A.) code for Field Performance Test Of Cooling Tower Fans. We shall be arranging all the testing instruments for measuring the above parameters. All the instruments will be calibrated and certificates will be provided before testing of fan.

We confirm guarantee of minimum 25%( 5%) reduction in power consumption for same duty conditions of your existing METALIC BLADED fan. Therefore, payback period or recovery of capital cost will be within 12 to 24 months after installing our EFFEN make FRP Fan. However, were confident that power saving will be in the range of 10% to 35% depending upon the actual duty conditions of your existing fan which will further reduce the payback period of FRP Fan.

Negligible skin friction due to glossy surface finish of the FRP Blades facilitates lower noise level so is more suitable for better ecological peaceful surroundings.

ENERGY SAVING : Lower H.P. motor can be used after installation of our FRP fan. REDUCTION IN THRUST LOAD : The thrust load due to dead weight of FRP fan which is less than that of aluminum / GRP blade fan, gets considerably reduced and thereby increases the life of Gear Box bearings. EFFICIENCY : The efficiency of fiberglass blades remain unaffected throughout its life as it is immune to corrosion and erosion. Therefore, the operating cost with our FRP fan will be much less as compared to aluminum / GRP blade fan. EASE OF MAINTENANCE : The fan hub assembly has been designed in such a way that dismantling and assembling of the FRP fan reduces the down time or maintenance power requirement and maintenance cost of the fan.

COMMERCIAL SR NO 01. Design, Engg. Mfg. D E S C R I T I ON

TERMS UNIT

&

CONDITIONS RATE QTY AMOUNT

& Supply of effen energy saving & all

make following sizes of

FRP Fan Material of constructions other details as per

enclosed

technical annexure.

CT FAN DIA 450 MM

NO

11,250.00

03

33,750.00

Total (Rs.)

Rs.33,750.00

Rupees thirty three thousand seven hundred fifty only

ENERGY SAVING GUARANTEE 25%(5%)*


*Against metalic fan blade
PRICES The prices quoted above are based on Ex works basis, Howrah. Packing & Forwarding charges will be extra maximum of 5% of basic order value. EXCISE DUTY NOT APPLICABLE at actual subject to

TAXES

5% VAT .

VALIDITY

Our offer is valid for the period of 30 days from to-date.

DELIVERY PERIOD

The material will be dispatched

within 6-10 weeks from

the date of

receipt of your order clear in all respects.

TERMS OF PAYMENT

100% Against delivery within 7 days.

COMMISSIONING SUPERVISION

SCOPE: Commissioning supervision & performance testing of our FRP Fan. Charges: Rs.1,500/- per fan (INCLUDING SERVICE TAX).

TOOLS & TACKLES

The client has required to provide all general tools, puller etc. during the time of commissioning.

COMMISSIONING SUPPORT

The client required to provide two semi skilled working hands with our commissioning engineer during commissioning.

NOTE

We confirm to depute our service Engineer along with technician for commissioning supervision & performance testing of FRP Fan & request you to provide free Lodging and Boarding for them at your Guest House during the installation period of FRP Fan. Further, we confirm if we will unable to prove 25% (5%) power saving from your existing condition then we will take back our material at our own risk and cost and your advance will be returned to you with present banking interest within 30 days.

GUARANTEE

1. The material months

supplied by us will be guaranteed for a period of 18 from the date of manufacturing

from the date of dispatch or 12 months is earlier, against any

commissioning, whichever defects.

The above warranty is void if the material supplied is subject to abuse or service in excess of its design limitations. Notice of the defects must be given promptly after its discovery, otherwise, this warranty is void.

---------x---------

ENUMERATION OF POWER CONSUMPTION OF YOUR EXISTING FRP FAN VIS - A - VIS effen MAKE FRP FAN & CAPITAL RECOVERY DERIVED AS UNDER: (ALL CALCULATION W AS MADE ON ASSUMPTION BASIS. ACTUAL W ILL BE CALCULATE AS AND W HEN MATERIAL W ILL BE INSTALLED) A) B) Total power consumed by your (Data given by you) 3 NO(S) = 2.25 kw FAN @0.75 kw Power required to drive effen make Fan at same duty =1.6 KW conditions as above while confirming minimum 25%(5%) reduction in power after the replacement.. = 0.65 KWH

C) Saving in Power / Unit per Hour (A-B) D) No. of Units saved per year with operational period

E)

= 0.65 KW x 8400 working Hours of 350 working days @ 24 hrs / day. = 5,460 KWH Capital saved per year considering Rs. 4.00 Ps. tariff cost / =5,460 x 4.000/KW in your region.. = Rs.21,840/#Cost of Procurement = ------------------------------#(Capital saving per day) 33,750/62.40 /= 541 Days OR = 18 Months Pay-back period of our EFFEN Fan # (0.65 KW x 24 Hrs./ Day x Rs.4.00 Ps.)

F)

Please note that youll be recovering minimum capital saving of Rs.21,840/- per year after the installation of our effen aerodynamically designed energy efficient FRP fan against

confirmed power reduction guarantee of 25%(5%) . Besides pay back period / return on your investment of our effen FRP Fan will be within 18 months from the date of installation of the same at your site. However, your actual capital gain/recovery will be definitely more than above as were very much confident of achieving energy saving above guaranteed level which will replacement.

continuously save / reduce your prevailing motive power consumption after the

Das könnte Ihnen auch gefallen