Beruflich Dokumente
Kultur Dokumente
Document Type Parameter Date 2009-12-20 15:37 Search scope RNC, RN5.0 Managed Object ADJS Parameter name CPICH Ec/No Offset Abbreviated name AdjsEcNoOffset
ADJS
Cell Identifier
AdjsCI
ADJS
Change origin
ADJSChangeOrigin
ADJS
AdjsDERR
ADJS
HSDPAHopsIdentifier
ADJS
RTWithHSDPAHopsIdentifier
ADJS
AdjsSIB
ADJS
ADJSId
ADJS
AdjsLAC
ADJS
AdjsTxPwrRACH
ADJS
AdjsMCC
ADJS
AdjsMNC
ADJS
AdjsMNCLength
ADJS
NrtHopsIdentifier
ADJS
AdjsCPICHTxPwr
ADJS
AdjsScrCode
ADJS
RNC Identifier
AdjsRNCid
ADJS
RT HOPS Identifier
RtHopsIdentifier
ADJS
AdjsRAC
ADJS
Tx Diversity Indicator
AdjsTxDiv
Multiplicity: 1
HCConfiguration
HCConfiguration
HCConfiguration
HCConfiguration
HCConfiguration
Identification
HCConfiguration
HCConfiguration
HCConfiguration
HCConfiguration
HCConfiguration
HCConfiguration
HCConfiguration
HCConfiguration
HCConfiguration
HCConfiguration
HCConfiguration
Tx diversity indicator
HCConfiguration
Description The CPICH Ec/No Offset determines an offset value, which the UE adds to the CPICH Ec/No measurement result of the neighbouring cell before it compares the Ec/No value with the reporting criteria.
An intra-frequency neighbour cell is identified with the UTRAN Cell Identifier, which is composed of the Global RNC Identifier and the Cell Identifier. The modification is not possible if the new target cell is under the controlling RNC. Cross-check between RNC, WCEL and ADJS objects is required. The parameter defines the origin of the last configuration action affecting the object.
This parameter indicates whether the neighbouring cell is forbidden to affect the reporting range (addition/drop window) calculation, if it belongs to the active set.
The parameter identifies the parameter set (HOPS object) controlling the intra-frequency handovers of a user having HS-DSCH allocated. This parameter identifies the parameter set (HOPS object) controlling intra-frequency handovers of a user having HSDSCH allocated simultaneously with AMR speech CS RAB. The parameter determines whether the intra-frequency neighbour cell is included in the System Information Block 11&12&18 for the cell selection and re-selection procedures. The intra-frequency neighbour cell is included in the system information when the value of the parameter is "SIB". The intra-frequency neighbour cell is included in the extended system information when the value of the parameter is "SIBbis". The total number of intra-frequency, inter-frequency and GSM neighbour cells, which can be included in the System Information Block type 11 (SIB11), is 47. When HCS is used, the capacity is limited to 35 cells. System Information Block type 11bis (SIB11bis) increases the maximum number of adjacencies to 96. SIB11bis can only be decoded by the UEs which support 3GPP R6. If the total number of intra-frequency, inter-frequency and GSM neighbour cells, which are included in the System Information, exceeds the physical size of SIB data, the NBAP interface is not able to pack the neighbour cell information into the SIB data and the scheduling of the system information blocks fails. The cell is blocked by the system and an alarm 7771 WCDMA CELL OUT OF USE (BCCH scheduling error) is reported for the cell. Note: The parameter AdjsSIB does not affect intra-frequency measurements in CELL_DCH state of connected mode. That is, all intra-frequency neighbour cells are monitored for the soft(er) handover regardless of the value of the parameter AdjsSIB.
The PLMN Identifier and the Location Area Code (LAC) determine the Location Area (LAI) to which the intrafrequency neighbour cell belongs to.
This parameter indicates the maximum transmission power level that a UE can use when accessing the neighbouring cell on the RACH. The UE uses the parameter in the cell re-selection procedure. If the maximum output power of the UE is lower than the value of the parameter, the UE adds the power difference (dB value) to the minimum required CPICH Ec/No level, which the measurement result of the neighbouring cell must exceed before the cell re-selection is possible. An intra-frequency neighbour cell is identified with the UTRAN Cell Identifier, which is composed of the Global RNC Identifier and the Cell Identifier. Furthermore, the Global RNC Identifier is composed of the PLMN Identifier, which consists of the Mobile Country Code (MCC), the Mobile Network Code (MNC), and the RNC Identifier. The modification is not possible if the new target cell is under the controlling RNC. Cross-check between RNC, WCEL and ADJS objects is required. An intra-frequency neighbour cell is identified with the UTRAN Cell Identifier, which is composed of the Global RNC Identifier and the Cell Identifier. Furthermore, the Global RNC Identifier is composed of the PLMN Identifier, which consists of the Mobile Country Code (MCC), the Mobile Network Code (MNC), and the RNC Identifier. The modification is not possible if the new target cell is under the controlling RNC. Cross-check between RNC, WCEL and ADJS objects is required. The parameter defines whether 2 or 3 digits are used in the Mobile Network Code (MNC). When this parameter is modified also the MNC value used by the system is always changed. The modification is not possible if the new target cell is under the controlling RNC. Cross-check between RNC, WCEL and ADJS objects is required. This parameter defines the parameter set (HOPS object) which controls the intra-frequency handover of a non-real time (NRT) radio bearer to the neighbouring cell. This parameter indicates the transmission power level of the Primary CPICH (Common Pilot Channel) of the intrafrequency neighbour cell. The downlink scrambling code of the Primary CPICH (Common Pilot Channel) of the intra-frequency neighbour cell.
An intra-frequency neighbour cell is identified with the UTRAN Cell Identifier, which is composed of the Global RNC Identifier and the Cell Identifier. The Global RNC Identifier is composed of the PLMN Identifier and the RNC Identifier. The modification is not possible if the new target cell is under the controlling RNC. Cross-check between RNC, WCEL and ADJS objects is required. This parameter defines the parameter set (HOPS object) which controls the intra-frequency handover of a real time (RT) radio bearer to the neighbouring cell. The Location Area (LAI) and the Routing Area Code (RAC) determine the Routing Area to which the intra-frequency neighbour cell belongs to.
This parameter indicates whether the Primary CPICH of the intra-frequency neighbour cell is broadcast from two antennas. If the Primary CPICH is broadcast from two antennas, the UE measures the received code power from each antenna separately and sums the measurement results together in order to get the total received code power on the Primary CPICH.
Range: -10..10
1..65535
0 (Not defined), 1 (Network originated configuration action), 2 (NetAct RNW plan originated configuration action), 3 (Element Manager originated configuration action), 4 (Configuration action by automatic tuning function), 5 (Element Manager originated mass config action), 6 (NetAct originated direct RNW change) 0 (No), 1 (Yes) -
1..100
1..100
1..31
1..65535
-50..33
dBm
0..999
0..999
2 (2), 3 (3)
1..100
-10..50
0.1
dBm
0..511
1..4095
1..100
0..255
Default value 0
= UI_value
= UI_value
= UI_value
= UI_value
= UI_value
= UI_value
= UI_value
= UI_value
= UI_value
= UI_value * 10
= UI_value
= UI_value
= UI_value
= UI_value
Mandatory
Mandatory
The neighbouring cell can affect the reporting range calculation, if it belongs to the active set.
Mandatory
Optional
Optional
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Special value
Modification onLine
- Handover Control
onLine
unmodifiable
- Handover Control
onLine
- Handover Control
onLine
- Handover Control
onLine
- Handover Control
onLine
- SIB11 - SIB12
unmodifiable
- Handover Control
onLine
- SIB11 - SIB12
onLine
- Handover Control
- SIB18
onLine
- Handover Control
- SIB18
onLine
onLine
- Handover Control
onLine
- Handover Control
onLine
- SIB11 - SIB12
onLine
- Handover Control
onLine
- Handover Control
onLine
- Handover Control
onLine
- SIB11 - SIB12
onLine
ADJS creation
ADJS creation and modification (with restrictions). The modification is not possible if the neighbour cell is controlled by the local RNC.
ADJS creation and modification (with restrictions). The modification is not possible if the neighbour cell is controlled by the local RNC.
- HSDPAenabled of WCEL
- UEtxPowerMaxPRACH of WCEL
- AdjsMNCLength of ADJS
- AdjsMNC of ADJS
- HOPSId of HOPS
- PriScrCode of WCEL
- HOPSId of HOPS
Parameter relationships
The modification is always possible except if the new target cell is existing in local RNC. In this case the modification is done via the WCEL object. Cross-check between RNC, WCEL and ADJS objects is required.
The value must always be 0 (not used) if the intra-frequency neighbour cell is controlled by the local RNC; crosscheck between RNC, WCEL and ADJS objects is required.
Related features
Interfaces - RNC <-> UE - RAC <-> RNC - EM <-> RNC - RACApp <-> RAC - RNC <-> UE - RAC <-> RNC - EM <-> RNC - Planner <-> RAC - RNC -> RAC - RNC -> EM - RNC <-> UE - RAC <-> RNC - EM <-> RNC - RACApp <-> RAC
- Undefined:1080
HSDPA (optional)
- RAC <-> RNC - EM <-> RNC - RACApp <-> RAC - RAC <-> RNC - EM <-> RNC - RACApp <-> RAC - RAC <-> RNC - EM <-> RNC - RAC <-> RACApp
- Undefined:830
HSDPA (optional) AND HSDPA with Simultaneous AMR Voice Call (optional)
- Undefined:988
- Undefined:986 - Undefined:1243
- RAC <-> RNC - EM <-> RNC - RACApp <-> RAC - RNC -> UE - RNC <-> MSC - RAC <-> RNC - EM <-> RNC - RNC <-> UE - Planner <-> RAC - RNC <-> UE - RAC <-> RNC - EM <-> RNC - Undefined:839 - Undefined:737 (public) - Undefined:841
- RNC <-> MSC - RAC <-> RNC - EM <-> RNC - RNC <-> UE - Planner <-> RAC
- RNC <-> MSC - RAC <-> RNC - EM <-> RNC - RNC <-> UE - Planner <-> RAC
- RAC <-> RNC - EM <-> RNC - RACApp <-> RAC - RAC <-> RNC - EM <-> RNC - Planner <-> RAC - RNC <-> UE - RAC <-> RNC - EM <-> RNC - Planner <-> RAC - RNC <-> MSC - RAC <-> RNC - EM <-> RNC - Planner <-> RAC
- Undefined:1091
- Undefined:753 (public) - Undefined:843 - Undefined:841 - Undefined:722 (public) - Undefined:839 - Undefined:841 - Undefined:737 (public)
- RAC <-> RNC - EM <-> RNC - RACApp <-> RAC - RNC <-> MSC - RAC <-> RNC - EM <-> RNC - Planner <-> RAC
- Undefined:1091
- RNC <-> UE - RAC <-> RNC - EM <-> RNC - RACApp <-> RAC
Struct parameter