B72, L72
EXCELON 72 Filter/Regulator-Lubricator Combination Units 1/4" and 3/8" Port Sizes G True modularity with Norgren Quikclamp connections G Quick release bayonet bowl G Lubricator flow sensor provides a nearly constant oil/air ratio over a wide range of air flows G All around (360) visibility of the lubricator sight-feed dome simplifies installation and adjustment G Regulator balanced valve minimizes effect of variation in the inlet pressure on the outlet pressure
Use Micro-Fog models in applications containing one or more points of lubrication. Use Oil-Fog models to lubricate a single tool, cylinder, or other air driven device.

Technical Data
Fluid: Compressed air Maximum pressure: Transparent bowl: 10 bar (150 psig) Metal bowl: Manual or semi automatic drain: 17 bar (250 psig) Automatic drain: 10 bar (150 psig) Operating temperature*: Transparent bowl: -20 to +50C (0 to +125F) Metal bowl: -20 to +65C (0 to +150F)
* Air supply must be dry enough to avoid ice formation at temperatures below +2C (+35F).

Particle removal: 5 m, 25 m, or 40 m filter element Typical flow with 10 bar (150 psig) inlet pressure, 6,3 (90 psig) set pressure and 1 bar (15 psig) droop from set: ??? dm3/s (??? scfm) Waiting on lab test Manual drain connection: 1/8" Semi automatic drain connection: Push on 8 mm (5/16") ID tube Semi automatic drain operating conditions (pressure operated): Bowl pressure required to close drain: Greater than 0,1 bar (1.5 psig) Ordering Information Bowl pressure required to open drain: Less than 0,1 bar (1.5 psig) 3 Minimum air flow required to close drain: 0,5 dm /s (1 scfm) See Ordering Information on the following pages. Manual operation: Lift stem to drain bowl Automatic drain connection: 1/8" Automatic drain operating conditions (float operated): Bowl pressure required to close drain: Greater than 0,3 bar (5 psig) Bowl pressure required to open drain: Less than 0,2 bar (3 psig) Minimum air flow required to close drain: 0,1 dm3/s (0.2 scfm) Manual operation: Depress pin inside drain outlet to drain bowl ISO Symbol Nominal bowl size: Short bowl: 56 ml (1.9 fluid ounce) Long bowl: 65 ml (2.2 fluid ounce) Gauge ports: 1/8 PTF with PTF main ports Rc 1/8 with ISO Rc and ISO G main ports Filter with automatic drain, Regulator with relieving diaphragm, Recommended lubricants: See page Lubricator with manual drain N/AL.8.900.935

Materials: Body: Zinc Bonnet: Acetal Filter/Regulator valve: Brass Bowl: Transparent: Polycarbonate Transparent with guard: Polycarbonate, zinc guard Metal: Zinc Metal bowl liquid level indicator lens: Transparent nylon Sight-Feed dome: Transparent nylon Element: Sintered polypropylene Elastomers: Neoprene, nitrile, and Geolast

4/98

Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document.

N/AL.8.160.805.01

EXCELON 72 F/R-L Combination Units Ordering information. Models listed in order table have ISO G parallel threads. Filter/Regulator (F/R) has knob adjustment,
semi automatic drain, short transparent bowl without guard, 40 m element, relieving diaphragm, and 10 bar (150 psig) regulating spring. A gauge is not included. Lubricator (L) is a Micro-Fog model with 1/4 turn manual drain and short transparent bowl without guard.

Combination Unit Type Filter/Regulator-Lubricator (F/R-L)


*

Port Size G1/4 G3/8

Model C72H-2GK-ST3-RMN-QTN C72H-3GK-ST3-RMN-QTN

Flow* dm3/s (scfm) ?? (??) waiting on test ?? (??) waiting on test

Weight kg (lb) 1,08 (2.37) 1,08 (2.37)

Typical flow with 10 bar (150 psig) inlet pressure, 6,3 bar (90 psig) set pressure and 1 bar (15 psig) droop from set.

Alternative Models
Shutoff/Lockout Valve, Quikmount Standard Combination (No Shutoff/Lockout Valve, no Quikmount) With Shutoff/Lockout valve on inlet With Quikmount pipe adapters on inlet and outlet With Shutoff/Lockout Valve on inlet and Quikmount pipe adapter on outlet Combination Unit Type Standard Micro-Fog F/R-L Standard Oil-Fog F/R-L Micro-Fog F/R-L with porting block between filter/regulator and lubricator Oil-Fog F/R-L with porting block between filter/regulator and lubricator Port Size 1/4" 3/8" Threads PTF ISO Rc taper ISO G parallel Pressure Adjustment Knob T-bar

# 7 2 # - # # # - # ## -## # - # # #
Substitute C Accessories Quikclamp wall brackets No accessories Substitute B N

D E G

Lubricator Reservoir Substitute Short metal with liquid level indicator D Short transparent without guard T Long transparent without guard L Long transparent with guard W Lubricator Drain Closed bottom Manual, 14 turn Substitute E Q

Substitute H J K

Substitute 2 3 Substitute A B G Substitute K T

Regulator Gauge With gauge No gauge Regulation spring ** 0,3 to 2 bar (5 to 30 psig) 0,3 to 4 bar (5 to 60 psig) 0,3 to 10 bar (5 to 150 psig) Regulator Diaphragm Non-relieving Relieving

Substitute G N Substitute C F M Substitute N R

Filter Drain Automatic Manual, 14 turn Semi automatic

Substitute A Q S

Filter Bowl Substitute Short metal with liquid level indicator D Short transparent without guard T Long transparent without guard L Long transparent with guard W

Filter Element 5 m 25 m 40 m

Substitute 1 2 3

** Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges. Supplied in long bowl options only.

Accessories. See page N/AL.8.160.700.

N/AL.8.160.805.02

Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document.

4/98

EXCELON 72 F/R-L Combination Units Dimensions mm (inches). See pages N/AL.8.160.300, N/AL.8.160.400, N/AL.8.160.600, and N/AL.8.160.700 for dimensions of individual products and the Quikclamp wall bracket.
38 (1.50) 38 (1.50)

Standard Micro-Fog Type C72HStandard Oil-Fog Type C72JShown with optional gauge and Quikclamp wall bracket.

108 (4.22)

Alternative Micro-Fog Type D72HAlternative Oil-Fog Type D72JIncludes Shutoff/Lockout valve. Shown with optional gauge and Quikclamp wall brackets.

164 (6.46)

54 (2.11)

54 (2.11)

54 54 (2.11) 56 (2.24) (2.11)

59 (2.32)

38 (1.50)

Includes Quikmount pipe adapters. Shown with optional gauge and Quikclamp wall brackets.

Includes Shutoff/Lockout valve and Quikmount pipe adapter. Shown with optional gauge and Quikclamp wall brackets.
113 (4.48)

38 (1.50)

Alternative Micro-Fog Type E72HAlternative Oil-Fog Type E72J-

152 (6.00)

Alternative Micro-Fog Type G72HAlternative Oil-Fog Type G72J-

59 (2.32)

187 (7.35)

54 (2.11)

113 (4.48)

59 (2.32)

Includes porting block. Shown with optional gauge and Quikclamp wall brackets.

38 (1.50)

Includes Shutoff/Lockout valve and porting block. Shown with optional gauge and Quikclamp wall brackets.

38 (1.50)

Alternative Micro-Fog Type C72KAlternative Oil-Fog Type C72L-

143 (5.61)

Alternative Micro-Fog Type D72KAlternative Oil-Fog Type D72L-

59 (2.32)

200 (7.85)

54 35 54 (2.11) (1.39) (2.11)

54 (2.11)

92 (3.63)

54 (2.11)

59 (2.32)

38 (1.50)

Includes Quikmount pipe adapters and porting block. Shown with optional gauge and Quikclamp wall brackets.

149 (5.87)

Includes Shutoff/Lockout valve, Quikmount pipe adapter, and porting block. Shown with optional gauge and Quikclamp wall brackets.

38 (1.50)

Alternative Micro-Fog Type E72KAlternative Oil-Fog Type E72L-

188 (7.39)

Alternative Micro-Fog Type G72KAlternative Oil-Fog Type G72L-

59 (2.32)

222 (8.74)

54 (2.11)

149 (5.87)

4/98

Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document.

59 (2.32)

59 (2.32)

N/AL.8.160.805.03

EXCELON 72 F/R-L Combination Units

Typical Performance Characteristics


bar g PORT SIZE: 1/4" ELEMENT: 40 m INLET PRESSURE: 10 bar g (150 psig) RANGE: 0,3 to 10 bar (5 to 150 psig) OUTLET PRESSURE bar g psig psig B72 WITH L72 MICRO-FOG LUBRICATOR FLOW CHARACTERISTICS B72 WITH L72 OIL-FOG LUBRICATOR FLOW CHARACTERISTICS PORT SIZE: 1/4" ELEMENT: 40 m INLET PRESSURE: 10 bar g (150 psig) RANGE: 0,3 to 10 bar (5 to 150 psig)

12 150 OUTLET PRESSURE 9

12 150 9

120

120

90

60 3 30

NEW CURVES NEEDED Waiting on lab test

90

60 3 30

NEW CURVES NEEDED Waiting on lab test

0 0 0 10 20 20 40 30 60 80 AIR FLOW 40 100 50 dm3/s scfm

0 0 0 10 20 20 40 30 60 80 AIR FLOW 40 100 50 dm3/s scfm

Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.

N/AL.8.160.805.04

Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document.