Sie sind auf Seite 1von 3

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND DPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 48651 Identification Number

Date of Examination 08/09/2011

Examiner STANLEY IREHIE

Qualifications SNT LEVEL II MT, PT & UT

QTY

Description of Equipment BILLY PUGH X-904-4 PERSONNEL TRANSFER DEVICE

609-09

A steel construction Billy Pugh

X-904-4 Personnel Transfer Device c/w 4 lifting

points
SWL: Sling #: 32801-1 1000lbs

1 pc

TOP LEGGED:16mm X 20ft X Single Leg BOTTOM LEGGED:13mm X 5ft X 4 legged sling c/w master link assembly with thimble eye at all ends, o SWL: 3.9 t@0-90

Shackle ID:
PS 1, PS 2, PS 3, PS 4, PS5, PS 6, BP 12,

7pcs 4.75 tons bow safety pin shackle


DATE OF NEXT EXAMINATION: 07/03/2011

LOCATION :

MAIN DECK
TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-030 Penetrant Developer Wet Visible

SPECIFICATION : BS 7072, BS6210, BS3032 DPI METHOD:

PARTS EXAMINED: 4 Lifting Point and Entire Structure RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services

Address of premises where Test / Examination was held: HI 7

We hereby certify that on 08 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for Use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: STANLEY IREHIE Conducting: Examination only Doc No: JCIC-030

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 48652

Date of Examination 08/09/2011

Examiner STANLEY IREHIE

Qualifications SNT LEVEL II MT, PT & UT

Identification Number

QTY

Description of Equipment BILLY PUGH X-904-4 PERSONNEL TRANSFER DEVICE

718-10

A steel construction Billy Pugh

X-904-4 Personnel Transfer Device c/w four lifting

points
SWL: 1000Lbs

Sling #: 3114-10

1 set

TOP LEGGED:16mm X 20ft X Single Leg BOTTOM LEGGED:13mm X 5ft X 4 legged sling c/w master link assembly with thimble eye at all ends, o SWL: 3.9 t@0-90

Shackle ID:
BP 1, BP 2, BP 3, BP 4, BP 5, BP 6, BP 7,

7pcs

4.75 tons bow safety pin shackle


DATE OF NEXT EXAMINATION: 07/03/2011

LOCATION : DPI METHOD:

TOP DECK
TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A N/A

SPECIFICATION : BS 7072, BS6210,BS3032

PARTS EXAMINED: 4 Lifting Point and Entire Structure RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services

Address of premises where Test / Examination was held: HI 7

We hereby certify that on 08 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for Use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: STANLEY IREHIE Conducting: Examination only Doc No: JCIC-010

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 48653 Identification Number

Date of Examination 08/09/2011

Examiner STANLEY IREHIE

Qualifications SNT LEVEL II MT, PT & UT

QTY

Description of Equipment PERSONNEL WORK BASKET

WB 01

A steel construction Personnel Work Basket in dimensions 1.5mtrs X 1mtr X 2.4mtrs (Length X Width X Height) c/w 4 lifting points Tare Wt: 300Lbs SWL: 1000 Lbs Gross Wt: 1300 Lbs

Sling #: FE 0512-1

1 set

TOP LEGGED:16mm X 1mtr X Single Leg BOTTOM LEGGED:13mm X 1.2mtrs X 4 legged sling c/w master link assembly with thimble eyes at all ends, o SWL4.5 t@0-90

Shackle ID:
V 1, V 2, V 3, V4,

4pcs

3.25 tons bow safety pin shackle


DATE OF NEXT EXAMINATION: 07/03/2011

COMMENT This Equipment should be Load Tested Onshore


LOCATION : MPI METHOD:

MAIN DECK
TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink Wet Visible

SPECIFICATION : BS 7072, BS6210,BS3032

PARTS EXAMINED: 4 Lifting Points and Entire Structure RESULTS: No defect as at the time of inspection. Fit for Use Name and address of equipment owner: Transocean Support Services

Address of premises where Test / Examination was held: HI 7

We hereby certify that on 08 / 09 / 11 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for Use Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: STANLEY IREHIE Conducting: Examination only Doc No: JCIC-020