YSHIELD shielding paints are electro-conductive coatings for the protection of large areas against high-frequency (HF) radiation and (or) against low-frequency (LF) electric fields. Typical areas of application are single rooms, or the protection of whole buildings.
X X X X X X X The best since Well-established 10 years: Our new Pure silicate paint Well-established Brief description paint standard-paint for HF (+ LF) for HF (+ LF) for LF for HF (+ LF) Binding agent Pure acrylate Silicate Pure acrylate Pure acrylate Screening 38 dB (99.984%) 40 dB (99.99%) 36 dB (99.975%) 40 dB / 1-layer at 7.5 m/l at 7.5 m/l at 7.5 m/l at 7.5 m/l Screening 45 dB (99.997%) 47 dB (99.998%) 43 dB (99.995%) 2-layer at 2x 7.5 m/l at 2x 7.5 m/l at 2x 7.5 m/l Screening basis Carbon Carbon Carbon Carbon Color Black Black Black Black Building Building Building Building Application area interior / exterior interior interior / exterior interior / exterior Paint roller, Paint roller, Paint roller, Paint roller, paint brush, paint brush, paint brush, paint brush, Applicable with airless spraying airless spraying airless spraying airless spraying (nozzle > 525) (nozzle > 525) (nozzle > 525) (nozzle > 515) Substrates Almost all Mineral Almost all Almost all Water resistance Very high Good Normal Normal Pigmentation size < 100 m < 100 m < 100 m < 10 m Electr. resistance R > 2.0 R > 1.5 R > 3.0 R > 100 Temperature range < 200 C < 250 C < 100 C < 100 C Ecology Very good Very good Good Good Solvent Water Water Water Water VOC content * 0.0 g/l 0.0 g/l 0.2 g/l 0.2 g/l PAH content ** < 0.002 mg/kg < 0.002 mg/kg < 0.002 mg/kg < 0.002 mg/kg Sd-value ~ 0.1 m ~ 0.01 m ~ 0.1 m ~ 0.1 m pH-value 8 12 8 8 Adhesive pull strength 2.8 N/mm 2.5 N/mm 1.9 N/mm 4.1 N/mm Density 1.25 kg / l 1.3 kg / l 1.25 kg / l 1.05 kg / l MFFT 0 C 5 C 5 C 5 C Grounding Interior: ESW(+) + EB2; Interior: ESW(+) + EB2 Interior: ESW(+) + EB2; Interior: ESW(+) + EB2; required Exterior: ESA Exterior: ESA Exterior: ESA+EB2 Frost resistance *** Not frost-resistant Not frost-resistant 3 frost-/thaw cycles 3 frost-/thaw cycles Delivery sizes 1 / 5 Liter 1 / 5 Liter 1 / 5 Liter 1 / 5 Liter Shelf life 12 months 12 months 12 months 12 months Typical coverage, Int.: 7.5 m (81 ft); Int.: 7.5 m (81 ft); Int.: 7.5 m (81 ft); Int.: 7.5 m (81 ft) 1 liter, single-layer Ext.: 5 m (54 ft) Ext.: 5 m (54 ft) Ext.: 5 m (54 ft) Price per m EUR 5.60 EUR 5.60 EUR 5.60 EUR 4.48 Selection guide Our new standard Only recommended if Due to the frost resis- Our standard paint for paint for HF we always the focus is on maxi- tance our recommenda- LF we always recomrecommend! Supemum ecology. Without tion for shipping in the mend! Superior merior mechanical and a preservative agent. winter. chanical and chemical chemical properties. properties. Emission-free 0-VOC paint. * VOC = Volatile organic compounds. The actual EU limit value for wall paints is 30 g/l. ** PAH = Polycyclic aromatic hydrocarbons. The nonbinding EU limit value for children toys is 0.2 mg/kg. *** The given frost resistance is only valid liquid in the container, of course on the wall its permanent frost-resistant. Shielding HF Shielding LF
HSF 55
HSF 74
HSF 54
NSF 34
Updated: February 2014. Errors excepted. Prices are subject to chance without notice. All rights reserved.
Page 4
YSHIELD GmbH & Co. KG Am Schulplatz 2 94099 Ruhstorf GERMANY Phone: 0049-8531-31713-0 Fax: 0049-8531-31713-5 Email: info@yshield.com Internet: www.yshield.com
2,5 x
1x 4x
Underground
Interior and exterior: Excellent adhesion on all undergrounds like existing emulsion paints, sheetrock, wallpaper, cement, plaster, masonry, wood, etc.
Updated: February 2014. Errors excepted. Prices are subject to chance without notice. All rights reserved.
1x
1x
1x
1x
4x
400x
YSHIELD EMR-Protection Shielding paint HSF55 30 MHz Electromagnetic attenuation to ASTM D4935-10 4000 MHz
Top coating
Preferably covered with plastic bonded, water-based emulsion paints, facade paints or silicon resin paints. Very recommended are KEIM dispersion silicate paints (Biosil, Ecosil, Optil). Depending on their chemical composition, natural resin paints adhere relatively well. We do not recommend pure mineral paints! Due to the high adhesive tensile strenght of 2.8 N/mm (ETAG 004 recommends 0.25 N/mm), usable directly under pure organic plaster, no mineral pasters!
Oben: Einlagig mit 7,5 m pro Liter / Top: Single layer with 7.5 m per liter -100 CB RADIO DVB-T DVB-T LTE GSM 900 GSM 1800 UMTS
Unten: Zweilagig mit 2x 7,5 m pro Liter / Bottom: Double layer with 2x 7.5 m per liter WLan LTE WiMAX TETRA
Grounding
Must be grounded! We recommend interior the grounding strap EB2 plus grounding set ESW or ESW+, exterior the fiber additive AF3 plus the grounding set ESA.
Frost resistance
Not frost resistant, however our packages never freeze on shipping due to 10 years experience!
Shielding attenuation
Attenuation of 38 dB (shielding effectiveness of 99.984 %) in one layer, attenuation of 45 dB (shielding effectiveness of 99.997 %) with two layers. The attenuation is regularly tested in our own laboratory due to the standard ASTM D4935-10. The current measuring report is available uppon request.
Ingredients
Water, pure acylic binder, graphite, carbon black, eco-surfactant, eco-defoamer, thickener, preservative (MIT, BIT).
Page 5
YSHIELD GmbH & Co. KG Am Schulplatz 2 94099 Ruhstorf GERMANY Phone: 0049-8531-31713-0 Fax: 0049-8531-31713-5 Email: info@yshield.com Internet: www.yshield.com
2,5 x
1x 4x
Underground
Only interior: Good adhesion on absorbent, untreated, preferably mineral undergrounds like chalk, silicate, clay, etc.. Restricted use on absorbent emulsion paints, wallpapers, etc., please check first! Not usable on gypsum based substrates!
1x
1x
1x
1x
4x
400x
0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100
YSHIELD EMR-Protection Shielding paint HSF74 30 MHz Electromagnetic attenuation to ASTM D4935-10 4000 MHz
Updated: February 2014. Errors excepted. Prices are subject to chance without notice. All rights reserved.
Top coating
Can be covered with water-based, plastic bonded emulsion paints. Due to ecological reasons, KEIM dispersion silikate paints (Biosil, Ecosil, Optil) as well as AURO high-grade lime paint (no.344) and silicate paint (no.303) are highly recommended. Many natural resin paints and paints made of clay or lime putty are not recommended.
Oben: Einlagig mit 7,5 m pro Liter / Top: Single layer with 7.5 m per liter Unten: Zweilagig mit 2x 7,5 m pro Liter / Bottom: Double layer with 2x 7.5 m per liter CB RADIO DVB-T DVB-T LTE GSM 900 GSM 1800 WLan UMTS LTE WiMAX TETRA
Grounding
Must be grounded! We recommend interior the grounding strap EB2 plus grounding set ESW or ESW+, optional for crack bridging the fiber additive AF3.
Frost resistance
Not frost resistant, however our packages never freeze on shipping due to 10 years experience!
Shielding attenuation
Attenuation of 40 dB (shielding effectiveness of 99.99 %) in one layer, attenuation of 47 dB (shielding effectiveness of 99.998 %) with two layers. The attenuation is regularly tested in our own laboratory due to the standard ASTM D4935-10. The current measuring report is available uppon request.
Ingredients
Potassium silicate, water, graphite, carbon black, eco-surfactant, eco-defoamer, cellulose, no preservative agent.
Page 6
YSHIELD GmbH & Co. KG Am Schulplatz 2 94099 Ruhstorf GERMANY Phone: 0049-8531-31713-0 Fax: 0049-8531-31713-5 Email: info@yshield.com Internet: www.yshield.com
4x
400x
4x
400x
2,5 x
1x 4x
Underground
Interior and exterior: Excellent adhesion on various undergrounds like existing emulsion paints, sheetrock, wallpaper, cement, plaster, masonry, wood, etc.
1x Vorderseite / Front side 1x 1x Rckseite / Back side 1x 4x Rckseite / Back side 400x
0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100
YSHIELD EMR-Protection Shielding paint HSF54 30 MHz Electromagnetic attenuation to ASTM D4935-10 4000 MHz
Top coating
Updated: February 2014. Errors excepted. Prices are subject to chance without notice. All rights reserved.
Preferably covered with plastic bonded, water-based emulsion paints, facade paints or silicon resin paints. Very recommended are KEIM dispersion silicate paints (Biosil, Ecosil, Optil). Depending on their chemical composition, natural resin paints adhere relatively well. We do not recommend pure mineral paints! Due to the adhesive tensile strenght (according to ETAG 004) of at least 0.25 N/mm, usable directly under pure (not mineral) organic plaster.
Oben: Einlagig mit 7,5 m pro Liter / Top: Single layer with 7.5 m per liter Unten: Zweilagig mit 2x 7,5 m pro Liter / Bottom: Double layer with 2x 7.5 m per liter CB RADIO DVB-T DVB-T LTE GSM 900 GSM 1800 WLan UMTS LTE WiMAX TETRA
Grounding
Must be grounded! We recommend interior the grounding strap EB2 plus grounding set ESW or ESW+, exterior the fiber additive AF3 plus the grounding set ESA.
Frost resistance
Frost resistant (3 frost-/thaw cycles), shippable year-round by air cargo or by ship.
Shielding attenuation
Attenuation of 36 dB (shielding effectiveness of 99.975 %) in one layer, attenuation of 43 dB (shielding effectiveness of 99.995 %) with two layers. The attenuation is regularly tested in our own laboratory due to the standard ASTM D4935-10. The current measuring report is available uppon request.
Ingredients
Water, pure acylic binder, graphite, carbon black, additives, preservative (MIT, BIT).
Page 7
YSHIELD GmbH & Co. KG Am Schulplatz 2 94099 Ruhstorf GERMANY Phone: 0049-8531-31713-0 Fax: 0049-8531-31713-5 Email: info@yshield.com Internet: www.yshield.com
Underground
Interior and exterior: Excellent adhesion on various undergrounds like existing emulsion paints, sheetrock, wallpaper, cement, plaster, masonry, wood, etc.
Top coating
Updated: February 2014. Errors excepted. Prices are subject to chance without notice. All rights reserved.
Preferably covered with plastic bonded, water-based emulsion paints, facade paints or silicon resin paints. Very recommended are KEIM dispersion silicate paints (Biosil, Ecosil, Optil). Depending on their chemical composition, natural resin paints adhere relatively well. We do not recommend pure mineral paints! Due to the high adhesive tensile strenght even usable directly under pure (not mineral) organic plaster.
Grounding
Must be grounded! We recommend interior the grounding strap EB2 plus grounding set ESW or ESW+, exterior the fiber additive AF3 plus the grounding set ESA.
Frost resistance
Frost resistant (3 frost-/thaw cycles), shippable year-round by air cargo or by ship.
Shielding attenuation
Attenuation of 40 dB (shielding effectiveness of 99 %) in one layer. The shielding attenuation is regularly tested in our own laboratory. The current measuring report is available uppon request.
Ingredients
Water, pure acylic binder, carbon black, additives, preservative (MIT, BIT).
Page 8
YSHIELD GmbH & Co. KG Am Schulplatz 2 94099 Ruhstorf GERMANY Phone: 0049-8531-31713-0 Fax: 0049-8531-31713-5 Email: info@yshield.com Internet: www.yshield.com
Frost resistance
Frost resistant (3 frost-/thaw cycles), shippable year-round.
Processing
Stir in the additive (90 ml) into 5 liter shielding paint. Use an electro mixer for at least for one minute, that all mixes homogeneously .
Ingredients
Updated: February 2014. Errors excepted. Prices are subject to chance without notice. All rights reserved.
Frost resistance
Not frost resistant, however our packages never freeze on shipping due to 10 years experience!
Processing
The application is identical to a wallpaper glue! Avoid bucklings and wrinkles in the materials! The wall surface and the backside of the material is primed with a painters roller. The material is inserted wet-on-wet and fixed by hand (with disposable gloves) or with a pressure roller. Work quickly and strip by strip so that the glue wont get dry.
Technical data
Specially for the following materials: HNG80, HNG100, HNV80, NCV95 Delivery sizes: 5 liter Coverage: 17.5 m - 25 m, depending on the underground Ingredients: Acrylic binder, water, carbon black, additives, preservative (MIT, BIT) Color: Black Surface conductivity: 400 ohm (square resistance R) Page 9
YSHIELD GmbH & Co. KG Am Schulplatz 2 94099 Ruhstorf GERMANY Phone: 0049-8531-31713-0 Fax: 0049-8531-31713-5 Email: info@yshield.com Internet: www.yshield.com
Updated: February 2014. Errors excepted. Prices are subject to chance without notice. All rights reserved.
Preservation
Any kind of aqueous paint must be preserved. Isothiazolinone-compounds are generally controversial. But only in terms of CIT, which is not used in our paints. Further to this we reject preservation with BIT/silver, like utilized in eco-paints, as we dont want to use nanosilver. Our preservation with MIT/ BIT has a very low allergy potential which is also confirmed by MCS-customers. As an alternative, our shielding paint HSF74, is absolutely free from any kind of preservatives.
Sustainability
Due to its paint-typical holohedral structure without holes, our shielding paints have a nearly linear attenuation up to very high frequencies, regardless of the direction of signal polarization. Prooved up to 4/18/30 GHz (depending on the test method) they are very future-proof.
Grounding instructions
Please find more information about the necessary grounding under grounding accessories.
Areas of application
In private areas for the protection against cell phone towers, TV and radio broadcasting antennas, radar, digital standard cordless telephones, wireless networks or power supply lines. In commerce, science, research and defence facilities to prevent interception of data from wireless networks, to protect potentially bugged conference rooms or to shield technical equipment. Further applications: Data centers, technical rooms, schools, nurseries, hotel rooms, hospital rooms, recording studios, etc. Page 10
YSHIELD GmbH & Co. KG Am Schulplatz 2 94099 Ruhstorf YSHIELD GmbH & Co. KG Deutschland Am Schulplatz 2 94099 Ruhstorf Fon: 0049-(0)8531-31713-0 GERMANY Fax: 0049-(0)8531-31713-5 E-Mail: Phone: info@yshield.com 0049-8531-31713-0 Internet: www.yshield.de Fax: 0049-8531-31713-5 Email: info@yshield.com Internet: www.yshield.com
Updated: February 2014. Errors excepted. Prices are subject to chance without notice. All rights reserved. >> Stand 01.2012 << Irrtum und nderungen vorbehalten.
Page 21
YSHIELD GmbH & Co. KG Am Schulplatz 2 94099 Ruhstorf YSHIELD GmbH & Co. KG Deutschland Am Schulplatz 2 94099 Ruhstorf Fon: 0049-(0)8531-31713-0 GERMANY Fax: 0049-(0)8531-31713-5 E-Mail: Phone: info@yshield.com 0049-8531-31713-0 Internet: www.yshield.de Fax: 0049-8531-31713-5 Email: info@yshield.com Internet: www.yshield.com
YSHIELD Project examples Shielding one-family house (194 W/m 0.01 W/m), Austria
Updated: February 2014. Errors excepted. Prices are subject to chance without notice. All rights reserved. >> Stand 01.2012 << Irrtum und nderungen vorbehalten.
Page 22
YSHIELD GmbH & Co. KG Am Schulplatz 2 94099 Ruhstorf YSHIELD GmbH & Co. KG Deutschland Am Schulplatz 2 94099 Ruhstorf Fon: 0049-(0)8531-31713-0 GERMANY Fax: 0049-(0)8531-31713-5 E-Mail: Phone: info@yshield.com 0049-8531-31713-0 Internet: www.yshield.de Fax: 0049-8531-31713-5 Email: info@yshield.com Internet: www.yshield.com
Updated: February 2014. Errors excepted. Prices are subject to chance without notice. All rights reserved. >> Stand 01.2012 << Irrtum und nderungen vorbehalten.
Page 23
YSHIELD GmbH & Co. KG Am Schulplatz 2 94099 Ruhstorf YSHIELD GmbH & Co. KG Deutschland Am Schulplatz 2 94099 Ruhstorf Fon: 0049-(0)8531-31713-0 GERMANY Fax: 0049-(0)8531-31713-5 E-Mail: Phone: info@yshield.com 0049-8531-31713-0 Internet: www.yshield.de Fax: 0049-8531-31713-5 Email: info@yshield.com Internet: www.yshield.com
Updated: February 2014. Errors excepted. Prices are subject to chance without notice. All rights reserved. >> Stand 01.2012 << Irrtum und nderungen vorbehalten.
Page 24