Project name: Project number: Project file: System overview

New project evi moutsopoulou.sdp2

Location: Greece / Athens Grid voltage: 3~230 V

16 x Schott Solar GmbH SCHOTT PERFORM POLY 245 (PV-array 1)


Azimuth angle: 90, Inclination: 15, Mounting type: Roof, PV peak power: 3,92 kWp

24 x Schott Solar GmbH SCHOTT PERFORM POLY 245 (PV-array 2)


Azimuth angle: -90, Inclination: 15, Mounting type: Roof, PV peak power: 5,88 kWp

1 x STP 10000TL-10 Technical data


Total number of PV modules: PV peak power: Number of inverters: Nominal AC power: AC active power: Active power ratio: Annual energy yield (approx.)*: 40 9,80 kWp 1 10,00 kW 10,00 kW 102 % 12364,70 kWh Energy usability factor: Performance ratio (approx.)*: Spec. energy yield (approx.)*: Line losses (in % of PV energy): Unbalanced load: Self-consumption: Self-consumption quota: 100 % 83,6 % 1262 kWh/kWp --0,00 VA ----Sunny Design 2.20.1.R

Signature
*Important: The yield values displayed are estimates. They are determined mathematically. SMA Solar Technology AG accepts no responsibility for the real yield value which can deviate from the yield values displayed here. Reasons for deviations are various outside conditions, such as soiling of the PV Modules or fluctuations in the efficiency of the PV modules.

1/2

Evaluation of design
Project name: New project Project number: Project file: evi moutsopoulou.sdp2 Part project 1 Location: Greece / Athens Cell temperature: Record Low Temperature: -10,00 C Average High Temperature: 50,00 C Record High Temperature: 70,00 C

1 x STP 10000TL-10
PV peak power: Total number of PV modules: Number of inverters: Max. DC power (cos = 1): Limitation of AC active power: Max. AC active power (cos = 1): Grid voltage: Nominal power ratio: Displacement power factor cos : 9,80 kWp 40 1 10,20 kW 10,00 kW 10,00 kW 230 V 104 % 1 STP 10000TL-10

Technical data
Input A: PV-array 2 24 x Schott Solar GmbH SCHOTT PERFORM POLY 245, Azimuth angle: -90, Inclination: 15, Mounting type: Roof Input B: PV-array 1 16 x Schott Solar GmbH SCHOTT PERFORM POLY 245, Azimuth angle: 90, Inclination: 15, Mounting type: Roof Input A: Number of strings: PV modules per string: Peak power (input): Typical PV voltage: Min. PV voltage: Min. DC voltage (Grid voltage 230 V): Max. PV voltage: Max. DC voltage (PV): Max. current of PV array: Max. DC current: Max. short-circuit current: Input B:

2 12 5,88 kWp 330 V 300 V 150 V 502 V 1000 V 16,0 A 22,0 A 33,0 A

1 16 3,92 kWp 440 V 401 V 150 V 670 V 1000 V 8,0 A 11,0 A 12,5 A

PV/Inverter compatible

Sunny Design 2.20.1.R

2/2