Sie sind auf Seite 1von 6

CONCREWALL ROOF PANEL

CONCREWALL ROOF PANEL - Solutions

Standard Roof Panel Two beams Rebar Reinforcing

Standard Roof Panel Two Precast beams Lattice Girder

RANGE OF EMPLOYMENT
UNIDIRECTIONAL ROOF SLAB UP TO 5 5,00m 00 SPAN

QUANTITY OF CONCRETE (Rck 300) WEIGHT OF THE POURED CONCREWALL SLAB

0.071 m3/m2 (P) 175 Kg/m2

MAXIMUM LOAD Qmax (Kg/m2) ACCORDING TO THE ADDITIONAL REINFORCING BARS

Weight (Kg/m) 1.23 1.50 1.78 2.10 2.42


Qmax

Steel Reinforcing 210 110+112 212 112+114 214


for

<co

Span 2 3544 4324 5104 5718 5718


1853

(m) 2.5 2268 2767 3267 3856 4446

CENTER CENTER

1459

3 1575 1922 2268 2678 3088

1203

3.5 1157 1412 1667 1968 2268

1023

4 886 1081 1276 1506 1737


891

4.5 700 854 1008 1190 1372


788

5 567 692 817 964 1112


707

For the use of such values the manufacturing company will provide to increase the resistant section to the negative moments, verifying the following relationship .

<co, or with shear reinforcing with <c1

SCHEME OF CALCULATION

Qmax P = Qpermanent + Qaccidental

N.B. The calculations have been made considering the moment in the center element equal to the extremity with value QL2/12, considering L equal to the distance between the axis of the bearing structures (for safety conditions considering the permanent points on the external sides) in the calculation of the moment and L-15 in the shear calculation.

RANGE OF EMPLOYMENT
UNIDIRECTIONAL ROOF SLAB UP TO 6 6,00m 00 SPAN

QUANTITY OF CONCRETE (Rck 300) WEIGHT OF THE POURED CONCREWALL SLAB

0.086 m3/m2 (P) 212 Kg/m2

MAXIMUM LOAD Qmax (Kg/m2) ACCORDING TO THE ADDITIONAL REINFORCING BARS

Weight
(Kg/m)

Steel Reinforcing 110+112 212 112+114 214 114+116 216


for

Qmax

1.50 1.78 2 10 2.10 2.42 2.79 3.16

<co

Span 2 5285 6238 7364 8387 8387 8387


2780

(m) 2.5 3382 3992 4713 5434 6266 6602

CENTER CENTER

2188

3 2349 2773 3273 3774 4351 4929

1804

3.5 1726 2037 2405 2773 3197 3621

1535

4 1321 1560 1841 2123 2448 2773

1336

4.5 1044 1232 1455 1677 1934 2191

1182

5 846 998 1178 1359 1566 1774

1060

5.5 6 699 481 825 587 974 818 1123 943 1295 1088 1466 1232
961 879

For the use of such values the manufacturing company will provide to increase the resistant section to the negative moments, verifying the following relationship .

<co, or with shear reinforcing with <c1

SCHEME OF CALCULATION

Qmax P = Qpermanent + Qaccidental

N.B. The calculations have been made considering the moment in the center element equal to the extremity with value QL2/12, considering L equal to the distance between the axis of the bearing structures (for safety conditions considering the permanent points on the external sides) in the calculation of the moment and L-15 in the shear calculation.

RANGE OF EMPLOYMENT
UNIDIRECTIONAL ROOF SLAB UP TO 7 7,00m 00 SPAN

QUANTITY OF CONCRETE (Rck 300) WEIGHT OF THE POURED CONCREWALL SLAB

0.095 m3/m2 (P) 233 Kg/m2

MAXIMUM LOAD Qmax (Kg/m2) ACCORDING TO THE ADDITIONAL REINFORCING BARS

Weight Steel Reinforcing Span


(Kg/m)

1.78 2.10 2.42 2.79 3.16


Qmax

212 112+114 214 114+116 216


for

2 7372 8703 9912 9912 9912


3335

(m) 2.5 4718 5570 6422 7405 7803


2626

Center

Center

3 3277 3868 4460 5142 5825


2165

3.5 2407 2842 3277 3778 4280


1842

4 1843 2176 2509 2893 3277


1603

4.5 1456 1719 1982 2286 2589


1419

5 1180 1393 1606 1851 2097


1272

5.5 975 1151 1327 1530 1733


1154

6 694 967 1115 1286 1456


1055

6.5 698 824 950 1095 1241


972

7 602 710 819 945 1070


901

<co

For the use of such values the manufacturing company will provide to increase the resistant section to the negative moments, verifying the following relationship .

<co, or with shear reinforcing with <c1

SCHEME OF CALCULATION

Qmax P = Qpermanent + Qaccidental

N.B. The calculations have been made considering the moment in the center element equal to the extremity with value QL2/12, considering L equal to the distance between the axis of the bearing structures (for safety conditions considering the permanent points on the external sides) in the calculation of the moment and L-15 in the shear calculation.

PANEL POLITSOL PERFORMANCE

Site Panels Assembling g - Scafolding g

Roof Panels Reinforcing FLOORS AND ROOF BUILT WITH CONCREWALL PANELS OFFERS NOTABLE ADVANTAGES AS: Simplicity in the site assembling, with geometries predisposed in factory as from the structural project Site lifting devices simplified, due to the lightness of the elements Dead load reduced with notable reduction of the seismic masses Absolute certainty of the thermal isolation continuity

Roof Concrete Pouring

Das könnte Ihnen auch gefallen