Sie sind auf Seite 1von 1

3750

8100

8100

8100

8100

8100

8100

8'

10

NOTES:

69530
56100

13430
4830

200

5960

1716750

200

2760

300

5800

8180
200

5 m
FFL +1715800
screed (Fr - 09)

UTILITY 2

B2.052
D10

1715800

Depth of foundation to be determined on site.

All reinforced concrete works to structural engineer's


detail.

A single layer of 3 ply bituminous felt to be provided


between masonry and R.C. works.

Drains passing under driveways and buildings to be


encased with minimum 150mm thick concrete surround.

All plumbing and drainage to be to the approval and


satisfaction of M.H.O.

DATE

DETAILS

10.10.13 FOR CONSTRUCTION


23.10.13 FOR CONSTRUCTION: West core wall moved 50mm, grid 2
aligned with str. grid, FFL adjusted for screeds
06.12.13 FOR CONSTRUCTION
16.01.15 Oil tank sump pit position revised

B2.23

B2.25

10 m
FFL +1714730
B2.28 Power
200float (Fr 4260
- 10)

B2.27

B2.053
D09

34

29

B2.30

B2.19

B2.20

B2.22

B2.24

B2.26

l
pica
TyB2.32

Painted Kerb Marking


Stormwater
refer to
MECH. DWG

300mm R.C. Wall


Wa-18

B2.61

B2.59

B2.57

B2.55

B2.53

B2.51

B2.49

British American Insurance (Kenya) Ltd.


Britak Centre, Mara & Ragati Rd. Junction, Upper Hill
Tel: +254 (0)20-2833000 Fax: +254 (0)20-2717626
www.british-american.co.ke

ARCHITECTS

B2.33

B2.47

8100

B2.17

Compact
Car

4800

B2.15

4950

B2.14

CLIENT

B2.31

B2.34

johannesburg
97 second avenue
melville 2092
t +27 11 482 1648
f +27 11 482 1216
e office@jhb.gapp.net

FFL +1714725
screed (Fr - 10)

parking bays on ramp


R.C. Column
Wa-01

Painted white markings

cape town
150 longmarket street
cape town 8001
t +27 21 424 2390
f +27 21 426 1324
e office@ctn.gapp.net

B2.35

1:20
7000

Dwg WG-100

R.C. Column
E

B2.36

E
Dwg WG-100

2460

B2.56

B2.54

B2.52

B2.50

B2.48

B2.46
Painted Kerb Marking

B1.52

B1.50

B1.48

B1.46

B1.44

B1.42

B2.83

B2.81

22 m
FFL +1714725
screed (Fr - 09)

300mm R.C. Wall


Wa-18
B2.40

B2.79

B2.74

B2.75

B2.77

B1.59

B1.57

B1.55

B1.51

B1.49

B1.47

B1.45

B1.43

B2.82

B2.80

B2.78

B2.45

B2.44

B2.058
D07

2800

B2.057
D07

200

B2/R29

SERVICE

8100

273 0

B
B2.056
D09

35 m
FFL +1714725
100
screed (Fr - 09)
2440
500750 830 900

1610

300 1560

300

8100

8100

200

8100

8100

8100

3050

200

7790

405 0

810 0

10

33

405 0

31

10

370

8100

8'

GA PLAN Basement 2

70150
3750

0 1

DRAWING TITLE

58240

5500

300mm R.C. Wall


Wa-01

300mm R.C. Wall


Wa-01

300

8100

2600
200

B2.059
D07

B2.43

200

CIVIL/STRUCTURAL ENGINEER
Howard Humphreys (E.A) Ltd
Tel: +44 (0)20-4445254
Fax: +44 (0)20-4440299
www.howardhumphreys.com

6010

17 m
FFL +1714725
screed (Fr - 09)

200

250
200 200

service duct
B1.53

3280

4800

4050

SERVICE

B2.42200mm Blockwork
Wa-18

parking bays on ramp below

B
R

B2/R28

200mm Blockwork
Wa-18

3150

parking bays on ramp

B2.41

M
5560

Dwg WG-100

7000

Dwg WG-100

LOCAL SERVICES ENGINEER


Maiteri & Associates
Tel: +44 (0)20-4449694
Fax: +44 (0)20-4441756
maiteri@nbi.ispkenya.com

8930

5620

123456789

200

Ramp up to Basement 1

B2.055
D12

200

200mm Blockwork
Wa-18

300

300

parking bays on ramp below

1:20

150mm Blockwork

SERVICES ENGINEER
Chapman BDSP
Tel: +44 (0)20 7618 4800
Fax: +44 (0)20 7618 4801
www.chapmanbdsp.com

COORDINATION REQ.

2600

parking bays on ramp

1716750
300mm R.C. Wall
Wa-01

QUANTITY SURVEYOR
Barker & Barton (Kenya)
Tel: +254 (0)20-4042224
Fax: +254 (0)20-4040753
info@bbk.co.ke

4050

B1.54

Emergency Exit

1714730

4800

B1.56

B2/R27

B2.39

300mm R.C. Wall


Wa-18
B1.58

11.75

B2.38

4800

B2.58

150mm R.C. Balustrade


Wa-18

150

B2.60

PROJECT MANAGER
Acorn Management Ltd.
Tel: +254 (0)20-2729064/5
Fax: +254 (0)20-2729059
www.acornmanagementafrica.com

3650

B2.62

4800

B2.64

150

BUILDING LINE

150
4800

B2.66

Typical

4800

D
B2.68

Triad House, 83 Muthaiga Road


P.O. Box 30725, 00100
Nairobi, Kenya
Tel: +254 (0)20 3749651/4/5/6
Fax: +254 (0)20 374021/ 3740754
Mobile: +254 (0)722708632/
(0)733220539
E-Mail: info@triad.co.ke
Website: www.triad.co.ke

CONSULTANTS

B2.37

parking bays on ramp

B2.69

SL
SL

Compact
Car

Compact
Car

B2.70

ALL
ALL

24300

B2.29

32

31

300mm R.C. Wall


wa-18

BASEMENT PARKING 2

150mm R.C. Balustrade


Wa-18

SL
SL

B2/R25

Water Feature Plant room

Ramp up

B2.71

BY

ALL
ALL

8100

R.C. Column
Wa-20 B2.21

9490

B2/R26

TO

3820

B2.18

200

200

9100

4950

COORDINATION
REQ.

300

300

All voids, suspended ceilings and partitions to be rodent


proof in accordance with the Government rodent
proofing regulations.

2530
300
4310
300
5220
6 m
B2/R24
FFL +1715800
screed (Fr - 09) DATA CENTRE

3490

33

27

B2.63

Dwg WG-100

ROAD IMPROVEMENT LINE

28900

PLOT BOUNDARY

200

1200

8100

93250

B2.051
D10

3320

3340

15 m
FFL +1715800
screed (Fr - 09)

Brickwork ties & central joint by structural engineer.

1200

16 m
FFL +1715800
screed (Fr - 09)

200

DATA CENTRE
TELECOM

M.I.P.

300

300mm R.C. Wall

7000

2380
330

200

2450

B2.67

Concrete block/stone walls less than 200mm thick to be


reinforced with hoop iron at every alternative course.

4720

B2.16

B2/R21

GAS
SUPPRESSION

B2.050
D03

120

1714730

200

2320

B2.049
D03

1m reinforced balustrade wall


(finish Wa - 18)

3310

service duct

200

B2.046
B2.048
D03 B2.047 D03
D03

4360

B2/R20

200

Foul Water
Sump

1723

2000

B2.062
D04

3340

S
B2.045
D31 M.I.P.

200

Painted white markings

B2.12

B2.65

All mechanical and electrical work is to be undertaken by


registered artisans.

Wa-18

B2.10

8100

300
1580

B2.060
D26

200 1680 200

200
1680
200
2530

300

4920

M.I.P.
B2.9

All SABS applicable codes of practice to be used.

2
3

B2/R22

7000

200

31 m
FFL +1716750
tiles (Fr-06)

3001290300

service duct

7 m

Lobby

2290

15 m
FFL +1716750
screed (Fr - 09)

B2/R31

6020

service duct

PK Fire Escape

B2.061
D09

PK Lift3

7 m

DATA CENTRE
UTILITY 1

COORDINATION REQ.

600

B2/R30

120 900

4800

1500

4900
200

200

8100

4250

300mm R.C. Wall


B2.73
B2.72

PK Lift2

7 m

9910

100

200
2390

200
1300
200

60 m
SSL - 6250
?

B2.042
B2.041 D03 B2.043
D03
D03

400
400

D08

B2.13

B2/R44

l
Typica

5860

PK Lift1

8100

8140
200

B2/R19

M.I.P.

25

3150

All work to be executed in strict accordance with by- laws


and regulations of the local authorities.

No.

R.C. lift shaft to structural eng. detail

R.C. Column
C

200mm Blockwork
Wa-20
B2.2
B2.4
200mm Blockwork
Wa-18

52430

1730 300

slab above

150mm Blockwork

8100

12380

Dwg WG-100

U
300

300mm R.C. Wall


Wa-01

52 m
SSL - 6250
power floated (Fr - 10)

FIRE FIGHTING TANK

108 bays incl. (incl. 8 M.I.P.)

3160

24

The contractor must obtain the architects' written


confirmation of any instructions which involve a variation
to the contract before putting work in hand.

B2/R43

FIRE FIGHTING TANK

7380

M.I.P.
B2.11

22

4800

16710

20

5.31

7000

95320

200

2000 B2.044

200

7760

Fire Sump Pit

B2.8

to sprinkler valves
above

200

200

Painted marking

300mm R.C. Wall


Wa-18

8100

B2.7

1 / 521
1 / 523

7000

B2.6

2700

13 m
FFL +1715800
B2.034
screed (Fr - 09)
D10

Stair Note:
Riser: 176.0 mm
Tread: 250mm

57 m
FFL +1715800
screed (Fr - 09)

1 / 522
1 / 523

B2.5

SERVICE

6700

4800

M.I.P.

2230
B2/R11

Plant Base

200

300
8100

M.I.P.

200

200mm Blockwork

STAFF ABLUTION

35 m
FFL +1715800
screed (Fr - 09)

8100

200

200
17 m
FFL +1715750
screed (Fr - 09)

PK Fire Escape

2320

B2/R16

2320

Each contractor shall be responsible for ensuring the


structural stability of all components of his work and
ascertain that the main structure is capable of supporting
all loads applied thereto.

B2.040
D08

SERVICE TBC

200

117 m
FFL +1715800
screed (Fr - 09)

slab above

97 m
FFL +1715800
screed (Fr - 09)

200

PASSAGE

26 m
200mm
Blockwork
FFL +1715800
screed (Fr - 09)

B2.033
D10

SERVICE TBC

B2.039
D08

B2/R10

B2/R09

LIFE SAFETY BOARD

B2/R18

B2.014
D05

200
200
2320
440

4140

Plant Base
B2.012
D07

LIFT
PIT

B2.073
D17

B2.063
D04

22220

200

Earth rod inspection pit


(refer to Elect. Eng. detail)

B2.035
D04

200

B2.013
D08

610

B2.3

B2.011
D07

Stair Note:
Riser: 199.2 mm
Tread: 250mm

Stair Note:
Riser: 170.0 mm
Tread: 275mm

126 m
FFL +1715750
screed (Fr - 09)

M.I.P.

B2.038
D10

2800

2320

MECHANICAL PLANT

300

117 m
FFL +1715800
screed (Fr - 09)

400

440

1715800
B2.032
D01

9000

B2.036
D04

10380

16620
B2.015
D05

B2/R32

1715800

33 m
FFL +1715800
screed (Fr - 09)

B2/R17

B2.009
D09

3000
B2.072
D17

300mm R.C. Wall


Wa-18

B2.031
D01

200mm Blockwork B2/R08


Wa-18
LV SWITCH
116 m
FFL +1715800
screed (Fr - 09)

DATA CENTRE

CIRCULATION

B2.010
D09

FIRE &
GOODS

fire lift door


position TBC

B2.065
D10

B2.064
D22

B2/R13

B2/R37

17020

MTR

LIFT
PIT

133 m
FFL +1716800
screed (Fr - 09)

B2.007
D07

B2.008
D09

LIFT
PIT

B2.071
D04

TOWER LIFT
LOBBY

LIFT
PIT

B2/R34

6750

B2.006
D08

B2/R12

LIFT
PIT

200 200
640

B2.005
D08

1400

200

200

B2.070
D04

72 m
FFL +1715800
screed (Fr - 09)

B2.037
D22

wall thickening
& crash slab
above TBC

LIFT
PIT

Stair Note:
Riser: 199.2 mm
Tread: 250mm

B2.016
D07

B2.068
D14

2001160

Redundant Room
FFL +1715800
screed (Fr - 09)

B2.1

15830

300

B2.004
D09

PK Fire Escape

B2.017
D07

B2.003
D08

9 m
FFL +1715800
200
200screed
1760
(Fr - 09)

1715800

7520

B2.019
D22

B2.002
D08

PASSAGE

200

4350
B2/R07

400

3300

B2.069
D10

200

B2/R35

TELCOM UTILITY B2.066


D10
2

18640
3600

200mm Blockwork
Wa-18

B2/R05

2000

Earth rod inspection pit


(refer to Elect. Eng. detail)

200

3100

B2.028
D01

B2.030
D01

1010

200

200

200

200

200 1600

1600

5090

7520

B2.001
D07

200
2150

Redundant Room B2.067


FFL +1715800
D10
screed (Fr - 09)

1715800

COORDINATION REQ.

gridline X

B2.018
D09

200
1690 200 1720 200 1500

3170

TELCOM UTILITY
1

6200

B2.027
D04

203 m
FFL +1715800
screed (Fr - 09)

200

300
5180
200

B2/R36

B2/R06

B2.029
D01

121 m
FFL +1715050
Resin (Fr - 26)
16380

Stair Note:
Riser: 175.0 mm
Tread: 250mm

Earth rod inspection pit


(refer to Elect. Eng. detail)

1340

B2/R03

29

CIRCULATION

17 m
FFL +1715800
screed (Fr - 09)

42900
8100

Plant
base

2180

3030

200mm Blockwork
Wa-20

3950

B2.026
D11

B2.022
D04

fall

OIL TANK

200

300

B2.021
D04

1715800

8570

B2/R41

37 m
FFL +1715750
power floated (Fr - 10)

NON-POTABLE WATER TANK

B2/R42

52 m
FFL +1715750
power floated (Fr - 10)

NON-POTABLE WATER TANK

12480
8100
8100

B2.023
D10

20660
B2.020
D06

Plant
base

300

200mm Blockwork
200
Wa-20

Plant
base

300

27

Contractors and subcontractors are to check all site


dimensions and levels before commencing work.
Figured dimensions are to be taken in preference to scale
dimensions. The architects are to be notified of any
variations.

void over

2000

90 m
SSL - 6250
power floated (Fr - 10)

Plant
base

1 / 520
1 / 522
3030

305 m
FFL +1715800
300screed
7420
(Fr - 09)

1750

4920

B2/R40

300mm R.C. Wall

25
300

1870

18780

RAINWATER ATTENUATION TANK

24

2000
SW drain & sump

200

300

2200
200
650

3120
300
300

6370

B2/R01

300

300

2220340

300mm R.C. Wall


Wa-18

300

9910

2060

300

20

300

4810

line of dropped slab

This drawing is copyright, reserved and remains the


property of GAPP /Triad JV;

Stair Note:
Riser: 162.5 mm
Tread: 250mm

CIRCULATION

BOREHOLE
300

Stair Note:
Riser: 175.0 mm
Tread: 250mm

B2.024
D10

3120

69 m
FFL +1715750
power floated (Fr - 10)

40 m
FFL +1715100
screed (Fr - 09)

200

fall

SERVICE

S-03

7000

8710

B2/R39

POTABLE WATER TANK

B2/R02

fall

7220

6840

5800

B2.025
D06

2580

Stair Note:
Riser: 175.0 mm
Tread: 250mm

300

B2/R38

70 m
FFL +1715750
power floated (Fr - 10)

200

POTABLE WATER TANK

300mm R.C. Wall


Wa-18

10160

4970

200

200

5200

5100

200

200

2420

4070

200

300

4800

8610

500

300

1440 200 1700

22390

1 / 521

300

1 / 520

4810

300

300

4820

200

in joint venture

5500

32

34

N
O
I
T
C
U
R
T
S
N
O
C
R
FO

SCALE

DRAWN

1 : 200 @ A1

1 : 200

FIRST ISSUE

PROJECT STATUS

10.10.13

For Construction

DRAWING No.

REV.

BAID 1700 - WG 101


PROJECT No.

BAID 1700

PROJECT

Proposed Office Tower