1. Components
Manifold tube
Threaded reducer
End cap
1. Components
Heat pump
Storage tanks
2. Clearances
4. Connect pipes
Manifold tubes
End cap
Elbows
T Piece
End cap
Isolation Valve
No Return Valve
Drain line must terminate at least 1 metre away from tank. (AS/NZS 3500.4)
Check position of tanks inlets/outlets must be parallel to wall. Fit the branch assembly to manifold and storage tank. Solder connections as required.
NB: Gate valve or ball valve ONLY to be used in branches DO NOT install non-return valves or loose jumper valves
Isolation Valve
Compression nut, Flared pipe end or similar
Tundish
Drain line must terminate at least 1 metre away from tank. (AS/NZS 3500.4)
Connect primary flow to heat pump. Note: non return valve is not required after primary pump.
Isolation Valve
Primary Pump
Connect to outlet
Isolation Valve
Drain line must terminate at least 1 metre away from Heat Pump and Tank(s). (AS/NZS 3500.4)
Conduit Gland
Connect wiring to primary pump using push-fit connectors on the terminal block.
Remove the protective cap from one of the tanks. Remove the threaded plug. Insert the sensor well into the tank and tighten firmly.
17. Commissioning