Sie sind auf Seite 1von 122

www.Go2Hydraulics.

com

1800-232-0646 (Intl.) +1-206-319-9433

Vickers

Vane Pump & Motor Design Guide


For Mobile Equipment

Revised 08/98

www.Go2Hydraulics.com

353

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Introduction
Over the past twenty years, the
application of hydraulics in agricultural,
construction and materials handling
vehicles has seen a meteoric rise. In
fact, virtually all modern vehicles use
fluid power, and new vehicles and
markets are appearing as fast as the
development of new products and
concepts will allow.
Vehicle size and work capacity are
growing. Todays front-end loaders, for
example, have bucket capacities equal
to the capacities of scrapers of just a few
years ago. To provide equipment with
still larger load capacities, and increased
speed to do the job faster, the trend is
toward high-speed, high-pressure
hydraulic pumps and motors that allow
system components to remain relatively
small.
To meet the ever increasing demands
for fast positive action, longer service life
and economical vehicle operation,
Vickers offers you the large selection of
top-quality, precision-built pumps and
motors described in the following pages.
They are backed by over seven
decades of experience with every type
of hydraulic equipment.
You can always depend on Vickers for
the finest, most advanced hydraulic
products and the best in customer
service. Vickers has the worldwide
facilities and skilled personnel to give
you prompt deliveries, volume
production, and application and service
assistance when you need it.

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Table of Contents
Applying Vane Units
Pump & Motor Characteristics and Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting Dimensions, Circuitry Requirements, Fluid and Fluid Cleanliness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reservoirs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump Startup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5
6
7
8

Pumps, Single - 20VQ through 45VQ Series


Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Optional Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Performance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Shaft Torque Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Pumps, Double - 2520VQ through 4535VQ
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Optional Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Performance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Shaft Torque Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Pumps, Triple 2520VQSV10 through 4535VQSV10 Series
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Performance Curves Reference Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Shaft Torque Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Pumps, Single Thru-Drive 25VQT*S through 45VQT*S
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Performance Curves Reference Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Thru-drive Rear Mountings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Optional Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Shaft Torque Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Pumps, Double Thru-Drive 3525VQT*S and 4525VQT*S
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Thru-drive Rear Mountings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Shaft Torque Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Pumps, Single V10 & V20 Series
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Optional Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

www.Go2Hydraulics.com

66
67
68
69
72
73
3

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Pumps, Double V2010 & V2020 Series


Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Optional Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

66
78
79
80
83
84

Pumps, Power Steering VTM42 Series


Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Specifications and Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

89
90
91
94

Motors M2U & M2-200 Series


Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Operating Specifications and Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Optional Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Performance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Motors 25M through 50M Series
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Specifications and Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Optional Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

103
104
105
107
108

Accessory Products
Foot Mounts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Filler/Breather Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
SAE 4-Bolt Solid Flanges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Oil Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Hydraulic Formulae . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Flow Capacities of Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Applying Vane Units


Pump Characteristics

Motor Characteristics

Maximum Speed

Minimum Speed

Maximum rated pump speeds are based


on one atmosphere of inlet pressure
(14.7 psia) with the pump at sea level
and operating with SAE 10W oil at 38
to 82 C (100 to 180 F), unless
otherwise specified.

Normal operating motor speeds can be


as low as 50 to 100 r/min. Lower
operating speeds are permissible
depending on torque requirements of
the motor and characteristics of the
driven load.

Minimum Speed

Stall Torque

Minimum recommended starting


speed, under fluid conditions stated
above, is generally 600 r/min.
However, the pump size, system
characteristics and environmental
conditions can raise or lower this speed.
A lower speed can often be achieved
after the pump has primed.

Motor stall torque ranges between 65%


and 100% of 1200 r/min running torque
for a given pressure differential across
the motor. This is dependent on the
specific angular position of the shaft at
stall and the volume supply of fluid to
the motor.

If low starting or operating speeds are


required, consult your Vickers
representative.

Motors may be used as retarders but


may not be used as hydraulic brakes.
Systems requiring positive holding
capabilities must be provided with
externally operated mechanical
holding devices.

Inlet Pressure
Recommended inlet pressure is
0 to 0,34 bar (0 to 5 psi) gauge.
Inlet pressure should not exceed
1,38 bar (20 psi). Inlet depressions
should not exceed 0,17 bar (5 of Hg
or 12.2 psia).

Rated Pressure
Pumps should not be operated at or
near rated pressures at idle speeds for
extended periods. Localized overheating
and damage can result.
Never assume pumps in a double, triple
or thru-drive pump assembly can be
simultaneously loaded to rated pressure.
Shaft loading must be checked for
excessive torque and side loads.

Pump Supercharge Pressure


A pressurized reservoir system does not
always assure a positive(supercharge)
pressure at the pump inlet. Vacuum
at the pump inlet can result during
cold start-ups. Avoid high speeds until
the circuit has warmed and supercharge
pressure actually exists at the pump
inlet. When vacuum breaker
pressure caps are used on the
reservoir, exercise implements to
obtain reservoir precharge.

www.Go2Hydraulics.com

Hydraulic Braking

The maximum pressure obtainable in a


system using a motor as a retarder
(pumping) is dependent upon speed. At
speeds below 1000 r/min, maximum
obtainable pressure is proportionally
diminished relative to speed as speed
approaches stall.
When a motor is used as a retarder,
adequate pressure must be provided at
the inlet port to prevent cavitation.

Drive Alignment
Concentricity and angular alignment of
shafts are important to pump life.
Misalignment can induce heavy loads
on bearings, causing premature failure.
Flexible coupling halves must be aligned
according to the coupling manufacturers
recommendations.

Universal Joints
When using double universal joint
couplings, the shafts must be parallel
and the yokes must be in line. The offset
should be kept as low as possible.
Maximum allowable offset will, of course,
vary with application conditions. The
pump shaft to universal joint diametral fit
should be close (major diameter fit) with
no looseness.

Mounting Pad Accessory Drives


A splined shaft is recommended on
applications where the pump shaft
is coupled directly into a transmission
or gearbox. Spline drives should
be lubricated.
The possibility of interference between
the shaft and transmission splines, due
to tolerance stack-up, can exist. To
reduce this possibility, side tooth spline
fits should be used. A side tooth fit and
short length of engagement permits
more flexibility and less tendency for
side loading than does a major diameter
fit spline or long spline engagement.

Consult your Vickers representative


before using motors as retarders.

Drives
Recommended Drives
Vickers units are designed for use on
direct coaxial drives using spline
connections and/or flexible couplings. If
drives imposing radial or axial loads, or
key drives, are being considered,
consult your Vickers representative for
additional information.

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

Mounting Dimensions
Requirements
Dimensional control requirements of the
customers mounting pad to which the
pump or motor is affixed are as follows.

Pilot Diameter
Concentricity of the customers female
pilot diameter relative to the effective
axis of the female drive must be within
0,10 mm (.004 in.) total indicator
reading. The clearance between the male
and female pilot diameters must be +0,01
to +0,05 mm (+.0005 to +.0020 in.).

Mounting Face
The customers mounting face to which
the pump or motor is affixed must be
square to the axis of the female drive
within 0,0381 mm per mm (.0015 inch
per inch).

Shafts
Dimensions of keyed shaft receivers
must be between +0,003 and +0,03 mm
(+.0001 and +.0010 in.) of the maximum
shaft diameter shown on the Vickers
installation drawing.

Circuitry Requirements
Valves
In the event of acceleration or
deceleration of the drive or driven
members, overrunning loads or system
bleed-off, control valves and circuitry
must provide a continuous supply of oil
to the pump or motor. This supply
should be sufficient to prevent transient
or continuous cavitation, but not so large
as to result in speeds beyond the
published maximum speed.
Protect against hydraulic surge
pressures (inlet, outlet or drain) applied
to or generated by the pump or motor.
Relief valves must prevent these surges
from exceeding published pressure
ratings.
Never assume a relief valve setting is
the maximum pressure a pump
experiences. Shock conditions may
exist which can exceed circuit and pump
limitations.

Piping
Hydraulic lines should be as short and
have as large an inside diameter as
possible. Where lines are long, it is
desirable to adapt to a larger capacity
line than a units ports specify. Inlet,
outlet and drain lines should not be

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

smaller than the nominal port size


shown on installation drawings. A Y
shaped inlet should not be used to feed
two separate pumps because one may
be starved and cavitate.
There should be as few bends and
fittings in lines as possible.
High-pressure lines and fittings are
restrictive to flow and may result in
excessive pressure drop through the
system. They should be used only
where necessary in a pressure line.

Hose
Because steering components move
during operation, their working hydraulic
lines consist mainly of flexible hoses.
Long lines may be partly flexible hose
and partly tubing where flexibility is not
required.
When installing a hose, allow enough
slack to avoid kinking. A taut hose will
not allow movement with pressure
surges. Slack in the line compensates
for surges, relieving strain. The hose
should not be twisted during installation
or while in operation. Twisting will
weaken the hose and loosen
connections.
For power steering pumps using a
remote reservoir, connecting hoses
should not exceed three feet in length. It
is highly desirable to design the
reservoir-pump relationship so that there
is always a static head on the pump inlet
port.
A neater installation is usually
obtainable by using extra fittings to
minimize unusually long loops in a line.
Hoses should be clamped to prevent
rubbing and entanglement with moving
parts. Where hoses are subject to
chafing, they should be run through
protective neoprene hose or shielded
metallic guards.

Fluid Considerations
Preferred Viscosity
Normal pump operation (at rated
conditions) is based on the use of SAE
10W oil in the 38 to 82 C (100 to
180 F) range (or comparable
viscosities).

Permissible Viscosity
When operating with SAE 10W oil in the
860 to 40 cSt (4000 to 180 SUS) range
(-12 to 35 C or 10 to 95 F oil temp.),
the speed and pressure of the pump
should be limited to 50% or less of their
respective rated value until the system
has warmed up. Caution must be used
in starting units when fluid viscosity is
greater than 860 cSt (4000 SUS). Care
should be exercised to warm up the
entire system (fluid). Remote
components (cylinders, motors) should
be actuated during the warm-up
process.
Fluid viscosities must not be less than
60 SUS, and temperatures should not
exceed 99 C (210 F), because the life
expectancy of rotating groups and
elastomers will decrease.
Care should be taken to change to
appropriate oil viscosities when climatic
conditions change. See
recommendations for mobile hydraulic
systems on pages 120 and 121. Consult
your Vickers representative for
applicable decreases in ratings, and
modifications, if fluids other than SAE
type oils are considered.

Fluid Cleanliness
Proper fluid condition is essential for
long and satisfactory life of hydraulic
components and systems. Hydraulic
fluid must have the correct balance of
cleanliness, materials, and additives for
protection against wear of components,
elevated viscosity and inclusion of air.
Essential information on the correct
methods for treating hydraulic fluid is
included in Vickers publication 561;
Vickers Guide to Systemic
Contamination Control, available from
your local Vickers distributor or by
contacting Vickers, Incorporated.
Recommendations on filtration and the
selection of products to control fluid
condition are included in this publication.
Recommended cleanliness levels using
petroleum oil under common conditions
are based on the highest fluid pressure
levels in the system. See Figure 1.
Fluids other than petroleum, severe
service cycles or temperature extremes
are cause for adjustment of these
cleanliness codes. See Vickers
publication 561 for exact details.

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Applying Vane Units

Product

1000 psi

Vane Pumps - fixed


Vane Pumps - variable
Piston Pumps - fixed
Piston Pumps - variable
Directional Valves
Proportional Valves
Pressure/Flow Controls
Cylinders
Vane Motors
Axial Piston Motors
Radial Piston Motors

20/18/15
18/16/14
19/17/15
18/16/14
20/18/15
17/15/12
19/17/14
20/18/15
20/18/15
19/17/14
20/18/14

System Pressure Level


2000 psi
3000+ psi
19/17/14
17/15/13
18/16/14
17/15/13
20/18/15
17/15/12
19/17/14
20/18/15
19/17/14
18/16/13
19/17/13

18/16/13
17/15/13
16/14/12
19/17/14
15/13/11
19/17/14
20/18/15
18/16/13
17/15/12
18/16/13

Filler/Breather
Most reservoirs are vented to the
atmosphere through an opening that lets
air leave or enter the space above the
oil as the oil level rises or falls. A
filler/breather unit containing an air
filtering element, such as shown on
page 118, is often used as the vent.
It must be large enough to handle
the air flow required to maintain
atmospheric pressure whether the
tank is full or empty.

Figure 1

Aeration

Location

Reservoir and circuit design must


prevent aeration of the fluid. Particular
care must be used to employ joints,
seals and gaskets that will not leak or
deteriorate. This is especially important
in low pressure and suction lines.
Connections should always be tight to
prevent air from entering the system.

Preferably, reservoirs should be located


above pumps. This creates a flooded
pump inlet which reduces the possibility
of pump cavitation.

It is best to use windows and sight


glasses in the reservoir and inlet lines
during prototype evaluation to determine
whether significant amounts of air are
present in the fluid. Any opaqueness or
milky appearance of the fluid in the lines
or reservoir indicates excessive
aeration. Bubbles on the surface of the
reservoir fluid may indicate that
excessive aeration is present.

Reservoirs
Oil Level
The oil level of the reservoir should be
as high as possible above the pump
suction line opening. All return lines
should discharge near the tank bottom,
always below the oil level, and as far
from the pump inlet as possible.
For power steering pumps using a
remote reservoir, the oil level should not
be lower than one foot below the pump
shaft centerline.
Reservoirs should incorporate a sight
gauge, dipstick or other means for easy
checking of the oil level. Without these
devices, the oil level often goes
unchecked and, should a leak occur, the
pump can be starved and damaged
from loss of lubrication.

www.Go2Hydraulics.com

Line Connections
Pump suction and tank return lines
should be attached to the reservoir by
flanges or welded heavy-duty coupling.
If the suction line is connected to the
bottom of the reservoir, the coupling
should extend above the bottom inside
the tank. This prevents residual dirt from
getting into the suction line when the
tank is cleaned. The seals used on all
suction line connections should be such
that they will not deteriorate and leak.

Baffle Plate
A baffle plate in the reservoir is desirable
to separate the suction and return lines.
The plate causes return oil to circulate
around the outer wall of the reservoir for
cooling before it re-enters the pump. It
also helps provide time for entrained air
to separate from the oil. Baffle plate
openings should be designed so that
cascade effects and resultant air
entrainment are minimized.

Magnets
Magnets in a reservoir should be able to
pick up ferrous particles not retained by
filters or strainers. Magnets should be
assembled to the support bars located
between suction and return lines, and be
accessible for cleaning.

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Pump Start-up Procedure


Preparation Prior to Start-up

Pump Start-up

The reservoir and circuit should be clean


and free of dirt and debris prior to filling
with fluid.

All controls should be placed in the


neutral position so the pump is unloaded
when started.

Circuit Cleanup

Start the engine and run at low idle.

The reservoir should be charged with


filtered hydraulic fluid. The fluid level
should be sufficient to prevent vortexing
at the suction connection to the pump
inlet. It is good practice to clean the
system by flushing and filtering, using an
external slave pump.

Once the pump is started, it should


prime and pump within a few seconds. If
it does not, make sure there are no
restrictions between the reservoir and
the inlet to the pump, and that there are
no air leaks in the inlet line and
connections. Also, make sure that
trapped air can escape from the outlet.

Filling Pump and Removing Air


If the pump is mounted above the fluid
level, it should be filled with fluid through
the outlet port.
If the pump is mounted below the fluid
level, the pump outlet fitting (or other
downstream fitting or plug) can be
loosened to allow fluid to displace the
air. It may be necessary to loosen the fill
cap on the reservoir to allow the fluid to
flow freely. When a solid stream of fluid
with no observed air begins to drain
through the loosened fitting, the fitting
should be retightened.

Run at low engine idle for approximately


five minutes. Then, while observing the
reservoir fluid level, operate the
implements. Extend all actuators to
maximum safe limits to completely fill the
system with fluid.
Do not run with the fluid level below the
low limit.
Add fluid to the reservoir to bring the
fluid to the proper fill level.

An air bleed valve in the outlet circuit is


also recommended to remove trapped
air. If such a device is used, the pump
should be filled with fluid before start-up.
In some cases, it may be possible to
prime the pump by running the engine
starter for five to ten seconds with the
throttle and/or ignition switch in the off
position. It will be necessary to loosen a
fitting or plug in the pump outlet to allow
air to escape.

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

VQ Series High Speed, High Presure Pumps

Single 35VQ

Thru Drive 35VQT*S

Triple 4525VQSV10F

Double 3525VQ

Design Features

Performance

Reliability & Efficiency

In all pumps, except the rear pump of


triple pumps, fluid flow is developed in a
cartridge which consists principally of a
cam ring, rotor, ten vanes, and unique
side plates and support plates. The
bimetallic flexible side plates are located
on each side of the rotor with their
bronze face toward the rotor and their
steel face toward the support plate. Two
cavities in each support plate hold high
pressure oil against the flexible side
plate, thereby hydrostatically balancing
the flexible plate and providing optimum
clearance with the rotor.

For a combination of maximum


horsepower in a small package, high
efficiency, serviceability and economy,
Vickers high output pumps are
unequalled anywhere in industry.

Axial and radial running clearances,


along with lubricating oil film on the rotor
and vanes, are optimized over the entire
operating pressure range. Excellent
cold-start capability and superior
resistance to seizure make Vickers VQ
pumps highly reliable and efficient.

www.Go2Hydraulics.com

Durability
Vickers high speed-high pressure
pumps give more staying power they
last. Their workhorse ruggedness has
been proved on the newest types of
giant earth-moving equipment.

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Replaceable Cartridge
OUTLET

The pump cartridge described under


design features is easy to service and
can normally be replaced in ten minutes
or less, without removing the pump from
its mounting. A small stock of cartridges
can serve many pump models on a
variety of vehicles.

ROTOR
VANE

Hydraulic Balance
Pump inlet and outlet pressure
chambers are diametrically opposed as
shown in Figure 2. As a result, the rotor
is hydraulically balanced. Bearings thus
encounter no hydraulic loads, assuring
long life.
Figure 3 shows an insert fitted into a slot
in the vane. Outlet pressure is applied
continuously only to the space between
the vane and insert. Top and bottom
areas of the vane are subject to either
inlet or outlet pressure, depending upon
the vanes location during rotor rotation.
See Figure 2. Complete hydraulic
balance is effected in the outlet pressure
areas. Outward thrust by the vane in the
inlet area is equal to the outlet pressure
times the projected area of the end of
the insert.

INLET

PASSAGE TO
UNDERSIDE
OF VANE

Figure 2

INLET OR
OUTLET
PRESSURE

CONTINUOUS
OUTLET
PRESSURE

Double Pumps
Double pumps provide a single power
source capable of serving two separate
hydraulic circuits, or of providing greater
volume through the combined delivery of
both sections. In either type of
application, two pumps in a single
housing result in a more compact,
simple installation and can be driven
through a single shaft coupling.

Triple Pumps
Because triple pumps have three pumps
in a single housing, they offer even more
application versatility than do the double
pumps described above.

Thru-Drive Pumps
These versions of single and double
pumps have a rear pad for directly
mounting and driving an additional
pump. Many different multi-pump
arrangements are thus possible.

www.Go2Hydraulics.com

Figure 3

Integral Valve Options


Single, double, and triple pumps are
available with flow control and priority
valve covers.
The flow control cover limits flow to the
operating system to the desired
maximum. Excess flow is diverted to
tank. On double and triple pumps, the
deliveries of the shaft-end and center
pumps are proportional to speed.
The flow control cover also includes a
relief valve to limit maximum operating
pressure. Operating pressures of the
shaft-end and center pumps of double
and triple pumps must be controlled by
separate, external relief valves.

A typical application for the flow control


is power steering, where it provides a
constant supply of oil throughout the
vehicle engines mid to high speed
range.
The priority valve cover maintains a
nearly constant flow to a primary circuit
and diverts remaining flow to a
secondary circuit. The amount of flow
going to the secondary circuit is
determined by pump delivery. The
primary circuit is protected by an integral
relief valve, but an external relief valve
must be provided for the secondary and
any additional circuit.

10

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Single Pump Operating Specifications


Model
Series

Delivery USgpm
@ 1200 r/min
7 bar (100 psi)

Displ.
cm3/r
(in3/r)

Max.
r/min

Max.
bar (psi)

Typical del.
L/min
(USgpm)
@ max. speed
& pressure

Typical
input
kW (hp)
@ max. speed
& pressure

20VQ

5
8
11
12
14
12
14
17
21

18,0 (1.10)
27,4 (1.67)
36,4 (2.22)
39,5 (2.41)
45,9 (2.80)
40,2 (2.45)
45,4 (2.77)
55,2 (3.37)
67,5 (4.12)

2700
2700
2700
2700
2700
2700
2700
2500
2500

210 (3000)
210 (3000)
210 (3000)
160 (2300)
140 (2000)
210 (3000)
210 (3000)
210 (3000)
210 (3000)

42,3 (11)
65,4 (17)
88,5 (23)
98,1 (25.5)
115,4 (30)
88,5 (23)
103,8 (27)
119,2 (31)
146,2 (38)

17,9 (24)
26,1 (35)
35,4 (47.5)
28,4 (38)
29,1 (39)
41,0 (55)
46,6 (62.5)
51,8 (69.5)
61,9 (83)

25
30
35
38

81,6 (4.98)
97,7 (5.96)
112,8 (6.88)
121,6 (7.42)

2500
2500
2400
2400

210 (3000)
210 (3000)
210 (3000)
210 (3000)

173,1 (45)
211,5 (55)
230,8 (60)
250,0 (65)

75,3 (101)
87,7 (117.5)
98,5 (132)
104,4 (140)

42
50
60

138,7 (8.46)
162,3 (9.90)
193,4 (11.80)

2200
2200
2200

175 (2500)
175 (2500)
175 (2500)

255,8 (66.5)
303,8 (79)
369,2 (96)

91,4 (122.5)
105,2 (141)
126,8 (170)

25VQ

35VQ

45VQ

Weight
kg (lb)

11,8 (26)

14,5 (32)

22,7 (50)

34,1 (75)

Performance constants: SAE 10W fluid @ 82C (180F), and pump inlet @ 0 PSIG (14.7 PSIA)
Note: Outlet pressure must always be higher than inlet pressure.
See page 5 for details.

www.Go2Hydraulics.com

11

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Model Codes
Single Pump

(F3) - 20VQ F - 5 - A - S -1 - C - 2 - K - 30 - L
1

1 F3 Viton seals
Omit if not required.

Intravane pump series

Integral valve options

18,0
27,4
36,4
39,5
45,9

5
8
11
12
14

in3/r
1.10
1.67
2.22
2.41
2.80

Port connections

Series
20VQ

Code

Inlet

SAE
4-bolt flg.
20VQ
AM* Metric
4-bolt flg.
20VQF&P B
SAE
Str. thd.
20VQF&P C
SAE
4-bolt flg.

Mounting & shaft seal assembly

Shaft type
1 Straight keyed
151 Splined

Code = SAE rating (USgpm) at


1200 r/min, 7 bar (100 psi)
cm3/r

10

11

10

12

Relief valve setting

(20VQF & 20VQP)


bar (psi)
A 17 (250)
B 35 (500)
C 52 (750)
D 70 (1000)
E 86 (1250)

F 100 (1500)
G 121 (1750)
H 140 (2000)
J 155 (2250)
K 175 (2500)

Geometric displacement

Code

F Foot mount with single shaft


seal
S Flange mount and double shaft
seal
Omit for flange mount with single
shaft seal.

Omit if not required


F Flow control and relief
P Priority valve and relief

Outlets
SAE
4-bolt flg.
Metric
4-bolt flg.
SAE
Str. thd.
SAE
Str. thd.

Outlet positions

(Viewed from cover end of pump)


A Opposite inlet port
B 90 CCW from inlet
C In line with inlet
D 90 CW from inlet

11

Design
Subject to change. Installation
dimensions remain the same for
designs 30 through 39.

12
Shaft rotation
(Viewed from shaft end of pump)
L Left hand or counterclockwise.
Omit for right hand.

9
Controlled flow rate
(20VQF & 20VQP)
3 11 L/min (3 USgpm)
4 15 L/min (4 USgpm)
6 23 L/min (6 USgpm)
7 27 L/min (7 USgpm)
8 30 L/min (8 USgpm)
10 38 L/min (10 USgpm)
11 42 L/min (11 USgpm)
12 45 L/min (12 USgpm)

* Same as code A port connections,


except metric threads for fastening
flanges.

NOTE: For options other than listed


above, i.e. shafts, ports,
displacements, and mountings,
contact your Vickers representative.

www.Go2Hydraulics.com

12

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Model Codes
Single Pump

25VQ (S) 21
1

F3 - Viton seals

Intravane pump series

Standard
Heavy duty
bearing bearing
25VQ
26VQ
35VQ
36VQ
45VQ

0 (L)
9

Port connections

Series Code
All
A

Omit if not required.

(S) 11 C

All

AM*

25VQ

25VQ

25VQ

Inlet
SAE
4-bolt flg.
Metric
4-bolt flg.
SAE
str. thd.
SAE
4-bolt flg.
SAE
str. thd.

Outlet
SAE
4-bolt flg.
Metric
4-bolt flg.
SAE
str. thd.
SAE
str. thd.
SAE
4-bolt flg.

Pilot designation

S - SAE per ISO 3019/1 (SAE J744)


Omit for standard pilot.
4

Geometric displacement

Code = SAE rating (USgpm) at 1200


r/min and 7 bar (100 psi
Frame
size
25V

35V

45V

Code

cm3/r

in3/r

12
14
17
21
25
30
35
38
42
50
60

40,2
45,4
55,2
67,5
81,6
97,7
112,8
121,6
138,7
162,3
193,4

2.45
2.77
3.37
4.12
4.98
5.96
6.88
7.42
8.46
9.90
11.80

*Same as code A port connections, except


metric threads for fastening flanges.

10

Mounting & shaft seal assembly

Outlet positions

(Viewed from cover end of pump)


A Opposite inlet
B 90 CCW from inlet
C In line with inlet
D 90 CW from inlet

Design

Subject to change. Installation


dimensions remain the same for designs
20 through 29

10

Rotation

(Viewed form shaft end of pump)


L - Left hand (counterclockwise)
Omit for right hand.

F Foot mounting with single


shaft seal
S Flange mount and double
shaft seal
Omit for flange mount with single shaft
seal.

Shaft type

With standard pilot, single shaft seal


1 Straight keyed
11 Splined
86 Straight keyed, heavy duty
With standard pilot, double shaft seal
123 Splined (not available on 45VQ)
130 Splined (for 45VQ only)
With SAE pilot, single or double shaft
seal
203 - Straight keyed, heavy duty
297 - Splined

Note: For options other than listed in


the model code, i.e. shafts, ports,
displacements and mountings, contact
your Vickers representative.

www.Go2Hydraulics.com

13

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions
20VQ Series

.375-16 UNC OR M10


19,0 (.75) DEEP

Dimensions in millimeters (inches).


50,8
(2.00)

SEE PAGE 119 FOR SELECTION OF


SAE 4-BOLT FLANGES FOR PORT
CONNECTION PADS.

101,60 (4.000)
101,55 (3.998)

101,6
(4.00)

OPTIONAL 1.062512 UN-2B STRAIGHT


THD. CONNECTION
FOR SAE HYD. FITTING

OUTLET CONNECTION
19,0 (.75)

.500-13 UNC-2B,
OR M12,
21,0 (.83) DEEP

155,4
(6.12)

OPTIONAL
1.625-12UN-2B
STRAIGHT THD
CONNECTION
FOR SAE
HYD FITTINGS

INLET CONNECTION
38,1 (1.50)

132,6
(5.22)
63,5
(2.5)

9,5
(.375)

146
(5.75)

SEE SHAFT OPTIONS STARTING


ON PAGE 17.
14,2 (.56)
THRU
2 HOLES

76,2
(3.00)

55,4
(2.18)

12,7
(.50)

174,6
(6.875)

.750-16UNF 2B THD.
FOR SAE HYD. FITTINGS

20VQF Series
Additional dimensions are
shown above.

3,2
(.125)

23,1
(.91)

PRIMARY OUTLET PORT

.875-14 UNF-2B THD


FOR SAE HYD. FITTINGS

20,6
(.81)
170,9
(6.73)

TANK PORT

113,5
(4.47)
12,7
(.50)
99,1
(3.90)
SEE SHAFT
OPTIONS
STARTING
ON PAGE 17.
50,0
(1.97)

50,8
(2.00)

www.Go2Hydraulics.com

78,5
(3.09)

153,7
(6.05)

14

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions
20VQP Series
Dimensions in millimeters (inches)
16,0 (.63)
16,0 (.63)
55,4 (2.18)

See preceding page for


additional dimensions.

181,6
(7.15)

SEE SHAFT OPTIONS STARTING


ON PAGE 17 .
56,4 (2.22)
.750-16 UNF-2B THD. FOR SAE HYD. FITTINGS
157,7
(6.21)
TANK PORT

PRIMARY OUTLET PORT

62,0
(2.44)

62,0
(2.44)
46,0
(1.81)
SECONDARY OUTLET PORT
.875-14 UNF-2B THD.
FOR SAE HYD. FITTINGS

25VQ Series
Dimensions in millimeters (inches)
.500-13 UNC OR M12
22,3 (.88) DEEP

58,7
(2.31)
PORT CONNECTION PADS ARE FOR
USE WITH 4-BOLT FLANGES.
SEE PAGE 119 FOR SELECTION.
58,7
(2.31)
.375-16 UNC OR M10
19,0 (.75) DEEP
INLET CONNECTION
38,1 (1.50)
76,2 (3.00) FOR SAE 4-BOLT
FLANGE PADS. 85,9 (3.38) FOR
1.875-12 STRAIGHT THREADED
INLET AND 1.312-12 OUTLET.
SEE MODEL CODE, PAGE 13.

164,1
(6.46)

OUTLET CONNECTION
25,4 (1.00)

120,7
(4.75) 38,1
(1.50)

SEE SHAFT OPTIONS STARTING


ON PAGE 17.
174,5
(6.87)

101,6
101,5
(4.000)
(3.998)

B
63,5
(2.50)

12,7
(.50)
9,53
(.375)

www.Go2Hydraulics.com

146,1
(5.75)

60,5
R.
(2.38)
14,2 (.56)
THRU 2 HOLES

15

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

35VQ Series
Dimensions in millimeters
(inches)

15,7
(.62)

50,8 (2.00) INLET

.4375-14 UNC-2B, OR M12, THD.


22,3 (.88) DEEP 4 HOLES
PORT CONNECTION PADS ARE FOR
USE WITH 4-BOLT FLANGES.
SEE PAGE 119 FOR SELECTION.

.500-13 UNC-2B OR M12 THD.


22,4 (.94) DEEP 4 HOLES
OUTLET CONNECTION
31,75 (1.25)
186,9
(7.36)

SEE SHAFT OPTIONS STARTING


ON PAGE 17.

125,5
(4.94)

212,7
(8.38)

38,1
(1.50)

C
82,6
(3.25)

B
69,9
(2.75)
A
69,9
(2.75)

181,0
(7.125)

127,0
126,9
(5.000)
(4.998)

147,6
(5.81)

9,5
(.375)

69,9
(2.75)

45VQ Series

17,5 (.69) 2 HOLES


FOR MOUNTING

15,7
(.62)

Dimensions in millimeters (inches).

.500-13 UNC-2B OR M14 THD.


23,8 (.94) DEEP 4 HOLES

PORT CONNECTION PADS ARE FOR


USE WITH 4-BOLT FLANGES.
SEE PAGE 119 FOR SELECTION.

.625-11 UNC-2B OR M16 THD.


22,3 (.88) USEABLE THD.
ENGAGEMENT 4 HOLES

38,1 (1.50) OUTLET


76,2 (3.00) INLET

216,9
(8.54)

SEE SHAFT OPTIONS STARTING


ON PAGE 17.

153,2
(6.03)

212,7
(8.38)

42,9
(1.69)

93,7
(3.69)
D

181,0
(7.13)
127,0
126,9
(5.000)
(4.998)

B
82,6
(3.25)
A
158,8
(6.25)

www.Go2Hydraulics.com

79,4
(3.125)

12,7
(.50)

147,6
(5.81)
17,5 (.69) 2 HOLES
FOR MOUNTING

16

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Optional Shafts

Splined Shafts

Dimensions in millimeters (inches)


B

See spline data table below


C

Pump

Shaft
Code

Spline Data
(See below.)

20VQ,
20VQF,
20VQP

151

44,1 (1.62)

9,53 (.375)

11,9 (.468)

4,1 (.16)

27,8 (1.09)

11

44,5 (1.75)

9,53 (.375)

11,1 (.437)

4,1 (.16)

27,8 (1.09)

25VQ

123

44,5 (1.75)

9,53 (.375)

15,7 (.62)

4,1 (.16)

27,8 (1.09)

297

41,1 (1.62)

9,53 (.375)

7,9 (.31)

4,1 (.16)

27,8 (1.09)

11

58,7 (2.31)

9,53 (.375)

11,1 (.437)

6,4 (.25)

35,1 (1.38)

123

58,7 (2.31)

9,53 (.375)

15,2 (.60)

5,5 (.21)

35,1 (1.38)

297

55,5 (2.19)

12,7 (.500)

7,9 (.31)

6,4 (.25)

35,1 (1.38)

11

61,9 (2.44)

12,7 (.500)

14,3 (.565)

9,7 (.38)

39,6 (1.56)

130

61,9 (2.44)

12,7 (.500)

15,2 (.60)

9,9 (.39)

40,4 (1.59)

297

55,5 (2.19)

12,7 (.500)

7,9 (.31)

9,7 (.38)

39,6 (1.56)

35VQ

45VQ

Spline Data Table


(Involute splines from above chart)
Spline Data
Reference

Number of
Teeth

Pitch

Major Diameter

Form Diameter

Minor Diameter

Minor Diameter

13

16/32

22,17 (.873)
22,15 (.872)

19,03 (.749)

18,16 (.715)

Major dia. fit

13

16/32

21,8 (.858)
21,6 (.852)

19,03 (.749)

18,16 (.715)

Side fit

14

12/24

31,70 (1.248)
31,67 (1.247)

27,4 (1.08)

26,42 (1.040)

Major dia. fit

14

12/24

31,2 (1.229)
31,1 (1.223)

27,4 (1.08)

26,42 (1.040)

Side fit

www.Go2Hydraulics.com

17

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Straight Key Shafts

Dimensions in millimeters (inches)


F
E

D
1,5 (.06) x 45
C
A

Pump
20VQ,
20VQF,
20VQP

25VQ

35VQ

45VQ

Shaft
Code

F key width
x length

58,7 (2.31)

9,53 (.375)

11,9 (.468)

22,23 (.875)
22,20 (.874)

24,5 (.966)
24,4 (.961)

4,75 (.187)
x 32 (1.25)

58,7 (2.31)

9,53 (.375)

11,1 (.435)

22,23 (.875)
22,20 (.874)

24,5 (.966)
24,4 (.961)

4,75 (.187)
x 32 (1.25)

86

77,7 (3.06)

9,53 (.375)

11,1 (.435)

25,37 (.999)
25,35 (.998)

28,3 (1.11)
28,1 (1.10)

6,36 (.250)
x 50,8 (2.00)

203

77,7 (3.06)

9,53 (.375)

7,9 (.31) 

25,40 (1.00)
25,35 (.998)

28,20 (1.11)
27,94 (1.10)

6,36 (.250)
x 49,2 (1.938)

73,2 (2.88)

9,53 (.375)

11,1 (.435)

31,75 (1.250)
31,70 (1.248)

35,36 (1.39)
34,10 (1.38)

7,94 (.313)
x 38,1 (1.50)

86

85,9 (3.38)

9,53 (.375)

11,1 (.435)

34,90 (1.374)
34,87 (1.373)

38,6 (1.52)
38,3 (1.51)

7,92 (.312)
x 54 (2.13)

203

84,1 (3.31)

12,7 (.500)

7,9 (.31) 

34,90 (1.374)
34,87 (1.373)

38,6 (1.52)
38,3 (1.51)

7,92 (.312)
x 54 (2.125)

62,0 (2.44)

12,7 (.500)

14,22 (.560)

31,75 (1.250)
31,70 (1.248)

35,36 (1.39)
34,10 (1.38)

7,92 (.312)
x 28,5 (1.12))

86

87,4 (3.44)

12,7 (.500)

14,22 (.560)

38,07 (1.499)
38,05 (1.498)

42,4 (1.67)
42,1 (1.66)

9,53 (.375)
x 50,8 (2.00)

203

90,4 (3.56)

12,7 (.500)

7,9 (.31) 

38,07 (1.499)
38,05 (1.498)

42,4 (1.67)
42,1 (1.66)

9,53 (.375)
x 57,1 (2.25)

 Shaft shoulder inside recess in pilot.

www.Go2Hydraulics.com

18

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
20VQ Single Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

CODE 12 & 14 PUMPS

bar (psi) CODE

136 (36)
129 (34)

CODE 5, 8 & 11 PUMPS

bar (psi)

CODE

106 (28)

7 (100)
70 (1000)

114 (30)

140 (2000)

83 (22)
76 (20)

7 (100)
70 (1000)
140 (2000)
210 (3000)

68 (18)
61 (16)
53 (14)

7 (100)
70 (1000)
140 (2000)
210 (3000)

45 (12)
38 (10)

98 (26)
11

DELIVERY L/min (USgpm)

7 (100)
70 (1000)
140 (2000)
210 (3000)

91 (24)

76 (20)
68 (18)
61 (16)
53 (14)
45 (12)

38 (10)
30 (8)
23 (6)

15 (4)

15 (4)

8 (2)

8 (2)
1200

1600

2000

2400

0
400

2800

bar (psi)

12

83 (22)

23 (6)

800

14

91 (24)

30 (8)

0
400

7 (100)
70 (1000)
140 (2000)
160 (2300)

106 (28)

98 (26)

DELIVERY L/min (USgpm)

121 (32)

800

1200

1600

2000

2400

CODE

2800

bar (psi)

CODE

37,3 (50)
210 (3000)

11

33,6 (45)

33,6 (45)

26,1 (35)
22,4 (30)
18,6 (25)

210 (3000)

140 (2000)

11

210 (3000)
140 (2000)

5
8

70 (1000)
140 (2000)

11
5

70 (1000)

70 (1000)

7 (100)
7 (100)
7 (100)

11
8
5

14,9 (20)
11,2 (15)
7,5 (10)
3,7 (5)
0
400

800

1200

1600

2000

SPEED r/min

www.Go2Hydraulics.com

2400

2800

INPUT kW (hp)

INPUT kW (hp)

29,8 (40)

29,8 (40)

140 (2000) 14
160 (2300) 12

26,1 (35)

70 (1000) 12

22,4 (30)
18,6 (25)
70 (1000) 14
70 (1000) 14

14,9 (20)
11,2 (15)
7,5 (10)
3,7 (5)
0
400

7 (100)
7 (100)
800

1200

1600

2000

2400

14
12

2800

SPEED r/min

19

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

25VQ Single & 25VQT*S


Thrudrive Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

MAXIMUM OPERATING SPEED CORRECTION


FACTORS BASED ON PUMP INLET CONDITIONS

Maximum operating speeds shown on


performance curves are for pumps
operating at 0 psi inlet condition. To
compute maximum operating speeds at
other inlet conditions, use appropriate
speed rating correction factor.

0,14
0,07
0,17
0,10

bar

0,07

0,14

0,21

0,28

0,34

bar

1.14
SPEED RATING
CORRECTION
FACTOR

1.12
1.10
1.08

Example:
Max. speed @ 0 psi inlet
Correction factor @ 5 in. Hg
Max. speed @ 5 in. Hg inlet

1.06

2700 r/min
x .93
2511 r/min

1.04
1.02
in. Hg

VACUUM

Pump inlet suction should not exceed 5


in. Hg vacuum. Positive pressure on inlet
should not exceed 1,4 bar (20 psi).

2
0.98

psi

1.0
2
3
4
5
SUPERCHARGE PRESSURE

0.96
0.94
0.92
0.90
0.88
0.86

bar (psi) CODE

CODE 14 & 21 PUMPS


170 (45)

bar (psi) CODE

DELIVERY L/min (USgpm)

7 (100)
70 (1000)
17
140 (2000)
210 (3000)
7 (100)
70 (1000) 12
140 (2000)
210 (3000)

133 (35)
114 (30)
95 (25)
76 (20)
57 (15)

DELIVERY L/min (USgpm)

CODE 12 & 17 PUMPS


151 (40)

151 (40)
133 (35)
114 (30)
95 (25)

38 (10)
19 (5)

1200

1600

2000

2400

0
400

2800

7 (100)
70 (1000)
140 (2000)
210 (3000)

14

57 (15)

19 (5)
800

21

76 (20)

38 (10)

0
400

7 (100)
70 (1000)
140 (2000)
210 (3000)

800

1200

1600

2000

2400

2800

67,1 (90)
210 (3000)

INPUT kW (hp)

44,7 (60)
37,3 (50)

210 (3000) 12
140 (2000) 17

29,8 (40)

140 (2000) 12

22,4 (30)

70 (1000) 17

INPUT kW (hp)

210 (3000) 17

52,2 (70)

52,2 (70)
44,7 (60)

29,8 (40)
22,4 (30)

70 (1000) 12

14,9 (20)

7,5 (10)

7 (100) 17
7 (100) 12

7,5 (10)

800

1200

1600

2000

SPEED r/min

www.Go2Hydraulics.com

2400

2800

210 (3000)

14

140 (2000)

21

140 (2000)

14

140 (2000)

21

140 (2000)

14

7 (100)
7 (100)

21
14

37,3 (50)

14,9 (20)

0
400

21

59,7 (80)

59,7 (80)

0
400

800

1200

1600

2000

2400

2800

SPEED r/min

20

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
35VQ Single & 35VQT*S
Thrudrive Pumps

MAXIMUM OPERATING SPEED CORRECTION


FACTORS BASED ON PUMP INLET CONDITIONS

Performance Constants:
SAE 10W fluid @ 82C (180).
Pump inlet @ 0 psig (14.7 psia)

bar

0,14 0,07
0,10
0,17

1.12
1.10

0,28

bar

SPEED RATING
CORRECTION
FACTOR

1.04
1.02
in. Hg

2
0.98

VACUUM

1.0

2
3
4
5
SUPERCHARGE PRESSURE

psi

0.96
0.94
0.92

bar (psi) CODE

CODE 25 & 35 PUMPS

bar (psi) CODE


7 (100)

CODE 30 & 38 PUMPS


284 (75)

265 (70)

265 (70)

7 (100)

246 (65)

246 (65)

70 (1000) 35
140 (2000)
210 (3000)

227 (60)

227 (60)

208 (55)

DELIVERY L/min (USgpm)

208 (55)

7 (100)
70 (1000) 25
140 (2000)
210 (3000)

189 (50)
170 (45)

70 (1000)
140 (2000)
210 (3000)

38

7 (100)
70 (1000)
140 (2000)
210 (3000)

30

189 (50)
170 (45)

151 (40)

151 (40)

133 (35)

133 (35)

114 (30)
95 (25)

114 (30)
95 (25)

76 (20)

76 (20)

57 (15)

57 (15)

38 (10)

38 (10)
19 (5)
800

1200

1600

2000

2400

2800

400

800

1200

1600

2000

2400

2800

111,9 (150)

111,9 (150)

104,4 (140)

104,4 (140)
210 (3000) 35

96,9 (130)

89,5 (120)

82,0 (110)

82,0 (110)
210 (3000) 25

67,1 (90)

140 (2000) 35

59,7 (80)
52,2 (70)

140 (2000) 25

44,7 (60)
37,3 (50)

67,1 (90)
59,7 (80)

70 (1000) 25

www.Go2Hydraulics.com

2000

2400

2800

2000 PSI

30

38

29,8 (40)

70 (1000)

30

7 (100)
7 (100)

38
30

14,9 (20)

1200
1600
SPEED r/min

38

70 (1000)

22,4 (30)

800

140 (2000)

37,3 (50)

14,9 (20)
7 (100) 35
7 (100) 25

30

44,7 (60)

22,4 (30)

7,5 (10)

210 (3000)

52,2 (70)

70 (1000) 35
29,8 (40)

38

74,6 (100)
INPUT kW (hp)

74,6 (100)

210 (3000)

96,9 (130)

89,5 (120)

(0)
400

0,34

1.06

284 (75)

DELIVERY L/min (USgpm)

0,21

1.08

Example:
Max. speed @ 0 psi inlet
2500 r/min
Correction factor @ 5 in. Hg x .92
Max. speed @ 5 in. Hg inlet 2300 r/min
Pump inlet suction should not exceed 5
in. Hg vacuum. Positive pressure on inlet
should not exceed 1,4 bar (20 psi).

INPUT kW (hp)

0,14

1.14

Maximum operating speeds shown on


performance curves are for pumps
operating at 0 psi inlet condition. To
compute maximum operating speeds at
other inlet conditions, use appropriate
speed rating correction factor.

19 (5)
400

0,07

7,5 (10)
(0)
400

800

1200
1600
2000
SPEED r/min

2400

2800

21

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

45VQ Single & 45VQT*S


Thru-drive Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

MAXIMUM OPERATING SPEED CORRECTION


FACTORS BASED ON PUMP INLET CONDITIONS
0,07

1.14
1.12
1.10

0,14

0,21

0,28

0,34 bar

SPEED RATING
CORRECTION
FACTOR

1.08
1.06
in. Hg

5 4 3 2
VACUUM

1.04
1.02
psi
1.0
2
3
4
5
0.98 SUPERCHARGE PRESSURE
0.96
0.94
0.92
0.90

CODE 42 & 60 PUMPS

416 (110)

0,14 0,07
0,17 0,10

bar

Maximum operating speeds shown on


performance curves are for pumps
operating at 0 psi inlet condition. To
compute maximum operating speeds at
other inlet conditions, use appropriate
speed rating correction factor.
Example:
Max. speed @ 0 psi inlet
2200 r/min
Correction factor @ 5 in. Hg x .91
Max. speed @ 5 in. Hg inlet 2002 r/min
Pump inlet suction should not exceed
5 in. Hg vacuum. Positive pressure on
inlet should not exceed 1,4 bar (20 psi).

0.88

bar (psi) CODE


7 (100)

398 (105)

0.86

70 (1000) 60
140 (2000)
175 (2500)

379 (100)
360 (95)

360 (95)

341 (90)

341 (90)

322 (85)

322 (85)

303 (80)

303 (80)

CODE 50 PUMPS

bar (psi) CODE


7 (100)
70 (1000) 50
140 (2000)
175 (2500)

70 (1000)

265 (70)

140 (2000)
175 (2500)

246 (65)

284 (75)
42

227 (60)

265 (70)
246 (65)
DELIVERY L/min (USgpm)

DELIVERY L/min (USgpm)

7 (100)
284 (75)

208 (55)
189 (50)
170 (45)
151 (40)
133 (35)

208 (55)
189 (50)
170 (45)
151 (40)
133 (35)

114 (30)

114 (30)

95 (25)

95 (25)

76 (20)

76 (20)

57 (15)

57 (15)

38 (10)

38 (10)

19 (5)
400

19 (5)
800

1200

1600

2000

2400

134,2 (180)

2800

400

1200

1600

2000

2400

2800

119,3 (160)
140 (2000) 60

104,4 (140)

89,5 (120)

175 (2500) 42

89,5 (120)

74,6 (100)

140 (2000) 42

59,7 (80)

70 (1000) 60

44,7 (60)

70 (1000) 42

29,8 (40)

INPUT kW (hp)

104,4 (140)

175 (2500) 50
140 (2000) 50

74,6 (100)
59,7 (80)
70 (1000) 50

44,7 (60)
29,8 (40)

7 (100) 60
7 (100) 42

14,9 (20)
0
400

800

175 (2500) 60

119,3 (160)
INPUT kW (hp)

227 (60)

800

1200

www.Go2Hydraulics.com

1600
2000
SPEED r/min

2400

2800

14,9 (20)
0
400

7 (100) 50
800

1200

1600
2000
SPEED r/min

2400

2800

22

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Double Pump Operating Specifications


Shaft End Pump
Model
Series

Delivery
Displ.
USgpm @ cm3/r
1200 r/min (in3/r)
7 bar
(100 psi)

2520VQ 12
14
17
21

3520VQ 25
30
35
38

3525VQ 25
30
35
38

4520VQ 42
50
60

4525VQ 42
50
60

4535VQ 42
50
60

Cover End Pump

Max. Max.
r/min bar
(psi)

Typical
del.
L/min
(USgpm)
@ max.
speed &
pressure

Typical
input
kW
(hp)
@ max.
speed &
pressure

Delivery
Displ.
USgpm @ cm3/r
1200 r/min (in3/r)
7 bar
(100 psi)

Max. Max.
r/min bar
(psi)

Typical
del.
L/min
(USgpm)
@ max.
speed &
pressure

Typical
input
kW
(hp)
@ max.
speed &
pressure

Wt.
kg
(lb.)

40,2 (2.45)
45,4 (2.77)
55,2 (3.37)
67,7 (4.12)

2700
2700
2500
2500

210 (3000)
210 (3000)
210 (3000)
210 (3000)

88,5 (23)
103,8 (27)
119,2 (31)
146,2 (38)

41,0 (55)
46,6 (62.5)
51,8 (69.5)
61,9 (83)

5
8
11
12
14

18,0 (1.10)
27,4 (1.67)
36,4 (2.22)
39,5 (2.41)
45,9 (2.80)

2700
2700
2700
2700
2700

210 (3000)
210 (3000)
210 (3000)
160 (2300)
140 (2000)

42,3 (11)
65,4 (17)
88,5 (23)
98,1 (25.5)
115,4 (30)

17,9 (24)
26,1 (35)
20,5
35,4 (47.5) (45)
28,4 (38)
29,1 (39)

81,6 (4.98)
97,7 (5.96)
112,8 (6.88)
121,6 (7.42)

2500
2500
2400
2400

210 (3000)
210 (3000)
210 (3000)
210 (3000)

173,1 (45)
211,5 (55)
230,8 (60)
250,0 (65)

75,3 (101)
87,7 (117.5)
98,5 (132)
104,4 (140)

5
8
11
12
14

18,0 (1.10)
27,4 (1.67)
36,4 (2.22)
39,5 (2.41)
45,9 (2.80)

2500
2500
2500
2500
2500

210 (3000)
210 (3000)
210 (3000)
160 (2300)
140 (2000)

38,5 (10)
61,5 (16)
80,8 (21)
90,4 (23.5)
105,8 (27.5)

16,5 (22)
24,0 (32.5) 34,0
33,0 (44)
(75)
26,1 (35)
26,8 (36)

81,6 (4.98)
97,7 (5.96)
112,8 (6.88)
121,6 (7.42)

2500
2500
2400
2400

210 (3000)
210 (3000)
210 (3000)
210 (3000)

173,1 (45)
211,5 (55)
230,8 (60)
250,0 (65)

75,3 (101)
87,7 (117.5)
98,5 (132)
104,4 (140)

12
14
17
21

40,2 (2.45)
45,4 (2.77)
55,2 (3.37)
67,5 (4.12)

2500
2500
2500
2500

210 (3000)
210 (3000)
210 (3000)
210 (3000)

79,5 (21)
91,0 (24)
119,2 (31)
146,2 (38)

38,0 (51)
43,0 (58)
51,5 (69)
61,9 (83)

138,7 (8.46) 2200 175 (2500) 255,8 (66.5) 91,4 (122.5) 5


162,3 (9.90) 2200 175 (2500) 303,8 (79)
105,2 (141) 8
193,4 (11.80) 2200 175 (2500) 369,2 (96)
126,8 (170) 11
12
14

18,0 (1.10)
27,4 (1.67)
36,4 (2.22)
39,5 (2.41)
45,9 (2.80)

2200
2200
2200
2200
2200

210 (3000)
210 (3000)
210 (3000)
160 (2300)
140 (2000)

32,0 (8.5)
51,0 (13.5)
68,0 (18)
77,5 (20.5)
91,0 (24)

14,5 (19.5)
21,0 (28.5) 43,0
28,5 (38.5) (94)
23,0 (31)
24,0 (32)

138,7 (8.46) 2200 175 (2500) 255,8 (66.5) 91,4 (122.5) 12


162,3 (9.90) 2200 175 (2500) 303,8 (79)
105,2 (141) 14
193,4 (11.80) 2200 175 (2500) 369,2 (96)
126,8 (170) 17
21

40,2 (2.45)
45,4 (2.77)
55,2 (3.37)
67,5 (4.12)

2200
2200
2200
2200

210 (3000)
210 (3000)
210 (3000)
210 (3000)

68,0 (18)
79,5 (21)
100,0 (26.5)
125,0 (33)

33,0 (44)
38,0 (51)
45,5 (61)
54,5 (73)

46,0
(101)

138,7 (8.46) 2200 175 (2500) 255,8 (66.5) 91,4 (122.5) 25


162,3 (9.90) 2200 175 (2500) 303,8 (79)
105,2 (141) 30
193,4 (11.80) 2200 175 (2500) 369,2 (96)
126,8 (170) 35
38

81,6 (4.98)
97,7 (5.96)
112,8 (6.88)
121,6 (7.42)

2200
2200
2200
2200

210 (3000)
210 (3000)
210 (3000)
210 (3000)

145,5 (38.5)
178,0 (47)
211,5 (55)
223,0 (59)

66,5 (89)
77,5 (104)
89,5 (120)
97,0 (130)

53,6
(118)

34,5
(76)

Performance constants: SAE 10W fluid @ 82C (180 F); pump inlet @ 0 PSIG (14.7 PSIA)
Note: Outlet pressure must always be higher than inlet pressure. See page 5 for details.

www.Go2Hydraulics.com

23

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Model Codes
Double Pump (without integral valves)

2520VQ (S) 12
1

F3 - Viton seals

Omit if not required.

3525VQ
4520VQ

4525VQ
4535VQ

Geometric displacement shaft end pump

Code = SAE rating (USgpm) at 1200 r/min and


7 bar (100 psi)
Frame
Code
Size
(USgpm) cm3/r
in3/r
2520VQ
12
40,2
2.45
14
45,4
2.77
17
55,2
3.37
21
67,5
4.12
35**VQ
25
81,6
4.98
30
97,7
5.96
35
112,8
6.88
38
121,6
7.42
45**VQ
42
138,7
8.46
50
162,3
9.90
60
193,4
11.80

Note: For options other than listed in


the model code, i.e. shafts, ports,
displacements and mountings, contact
your Vickers representative.

Geometric displacement cover end pump

Frame
Size
**20VQ

Pilot designation

S SAE per ISO 3019/1 (SAE J744)


Omit for standard pilot.

Code = SAE rating (USgpm) at 1200 r/min


and 7 bar (100 psi)

Intravane pump series

2520VQ
3520VQ

11 (S) 123 CC

**25VQ

4535VQ

Code
(USgpm)
5
8
11
12
14
12
14
17
21
25
30
35
38

cm3/r
18,0
27,4
36,4
39,5
45,9
40,2
45,4
55,2
67,5
81,6
97,7
112,8
121,6

in3/r
1.10
1.67
2.22
2.41
2.80
2.45
2.77
3.37
4.12
4.98
5.96
6.88
7.42

Mounting & shaft seal assembly

S Flange mount and double shaft seal


Omit for flange mount with single shaft seal.

Shaft type

With standard pilot, single shaft seal


1 Straight keyed
11 Splined
86 Straight keyed, heavy duty
With standard pilot, double shaft seal
123 Splined (not available on 45**VQ)
130 Splined (for 45**VQ only)
With SAE pilot, single or double shaft seal
203 - Straight keyed, heavy duty
297 - Splined

Port connections

Pump series
All
All
2520VQ
All but 4535VQ
2520VQ

Code
A
AM*
C
E
F

Inlet
SAE 4-bolt flg
Metric 4-bolt flg.
SAE 4-bolt flg.
SAE 4-bolt flg.
SAE 4-bolt flg.

Outlet no.1
SAE 4-bolt flg.
Metric 4-bolt flg.
SAE str. thd.
SAE 4-bolt flg.
SAE str. thd.

Outlet no. 2
SAE 4-bolt flg.
Metric 4-bolt flg.
SAE str. thd.
SAE str. thd.
SAE 4-bolt flg.

0 (L)
10

11

Port orientation

(Viewed from cover end of pump)


All series except 4535VQ
With No.1 outlet opposite inlet:
AA - No. 2 outlet 135 CCW from inlet
AB - No. 2 outlet 45 CCW from inlet
AC - No. 2 outlet 45 CW from inlet
AD - No. 2 outlet 135 CW from inlet
With No.1 outlet 90 CCW from inlet:
BA - No. 2 outlet 135 CCW from inlet
BB - No. 2 outlet 45 CCW from inlet
BC - No. 2 outlet 45 CW from inlet
BD - No. 2 outlet 135 CW from inlet
With No.1 outlet inline with inlet:
CA - No. 2 outlet 135 CCW from inlet
CB - No. 2 outlet 45 CCW from inlet
CC - No. 2 outlet 45 CW from inlet
CD - No. 2 outlet 135 CW from inlet
With No.1 outlet 90 CW from inlet:
DA - No. 2 outlet 135 CCW from inlet
DB - No. 2 outlet 45 CCW from inlet
DC - No. 2 outlet 45 CW from inlet
DD - No. 2 outlet 135 CW from inlet
Series 4535VQ
With No.1 outlet opposite inlet:
AA - No. 2 outlet opposite inlet
AB - No. 2 outlet 90 CCW from inlet
AC - No. 2 outlet inline with inlet
AD - No. 2 outlet 90 CW from inlet
With No.1 outlet 90 CW from inlet:
BA - No. 2 outlet opposite inlet
BB - No. 2 outlet 90 CCW from inlet
BC - No. 2 outlet inline with inlet
BD - No. 2 outlet 90 CW from inlet
With No.1 outlet inline with inlet:
CA - No. 2 outlet opposite inlet
CB - No. 2 outlet 90 CCW from inlet
CC - No. 2 outlet inline inlet
CD - No. 2 outlet 90 CW from inlet
With No.1 outlet 90 CW from inlet:
DA - No. 2 outlet opposite inlet
DB - No. 2 outlet 90 CCW from inlet
DC - No. 2 outlet inline with inlet
DD - No. 2 outlet 90 CW from inlet

10

Design

11

Shaft rotation

(Viewed form shaft end of pump)


L - Left hand (counterclockwise)
Omit for right hand.

*Same as code A port connections, except metric threads for fastening flanges.

www.Go2Hydraulics.com

24

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Model Codes

Double Pump (with integral valves)

2520VQ (S)
1

Intravane pump series

2520VQ
3

3520VQ

4520VQ

Pilot designation

S SAE per ISO 3019/1 (SAE J744)


Omit for standard pilot.
Integral valve options

F Flow control and relief


P Priority valve and relief

Geometric displacement cover end pump


Code = SAE rating (USgpm) at 1200
r/min and 7 bar (100 psi)
Frame
Code
Size
(USgpm) cm3/r in3/r
**20VQ 5
18,0
1.10
8
27,4
1.67
11
36,4
2.22
12
39,5
2.41
14
45,9
2.80
8

F3 Viton seals

Omit if not required.

12 E 11 (S) 297 CC 6 D 0 (L)

Geometric displacement shaft end pump

Code = SAE rating (USgpm) at 1200


r/min and 7 bar (100 psi)
Frame
Code
Size
(USgpm) cm3/r in3/r
2520VQ 12
40,2
2.45
14
45,4
2.77
17
55,2
3.37
21
67,5
4.12
3520VQ 25
81,6
4.98
30
97,7
5.96
35
112,8 6.88
38
121,6 7.42
4520VQ 42
138,7 8.46
50
162,3 9.90
60
193,4 11.80

Mounting & shaft seal assembly

S Flange mount and double


shaft seal
Omit for flange mount with single shaft
seal.
9 Shaft type
With standard pilot, single shaft seal
1 Straight keyed
11 Splined
86 Straight keyed, heavy duty

With standard pilot, double shaft seal


123 Splined (not available on
4520VQ)
130 Splined (for 4520VQ only)
With SAE pilot, single or double shaft
seal
203 Straight keyed, heavy duty
297 Splined

10

Inlet
SAE 4-bolt flg.
SAE 4-bolt flg.

14

11

Controlled flow rate USgpm

2, 4, 6, 7, 8, 10 or 12 USgpm

12

Relief valve setting bar (psi)

C 52 (750)
D 70 (1000)
E 86 (1250)
F 100 (1500)

13

G 121 (1750)
H 140 (2000)
J 155 (2250)
K 175 (2500)

Design

(Viewed form shaft end of pump)


L - Left hand (counterclockwise)
Omit for right hand.

Port connections

Pump series Code


2520VQ only
C
All pumps
E

13

10 Port orientation
(Viewed from cover end of pump)
With No.1 outlet opposite inlet:
AA - No. 2 outlet 135 CCW from inlet
AB - No. 2 outlet 45 CCW from inlet
AC - No. 2 outlet 45 CW from inlet
AD - No. 2 outlet 135 CW from inlet
With No.1 outlet 90 CCW from inlet:
BA - No. 2 outlet 135 CCW from inlet
BB - No. 2 outlet 45 CCW from inlet
BC - No. 2 outlet 45 CW from inlet
BD - No. 2 outlet 135 CW from inlet
With No.1 outlet inline with inlet:
CA - No. 2 outlet 135 CCW from inlet
CB - No. 2 outlet 45 CCW from inlet
CC - No. 2 outlet 45 CW from inlet
CD - No. 2 outlet 135 CW from inlet
With No.1 outlet 90 CW from inlet:
DA - No. 2 outlet 135 CCW from inlet
DB - No. 2 outlet 45 CCW from inlet
DC - No. 2 outlet 45 CW from inlet
DD - No. 2 outlet 135 CW from inlet

14
6

11 12

Outlet no. 1
SAE str. thd.
SAE 4-bolt flg.

Outlet(s) no. 2
SAE str. thd.
SAE str. thd.

Tank
SAE str. thd.
SAE str. thd.

Shaft rotation

(Viewed form shaft end of pump)


L - Left hand (counterclockwise)
Omit for right hand.

Note: For options other than listed in


the model code, i.e. shafts, ports,
displacements and mountings, contact
your Vickers representative.

www.Go2Hydraulics.com

25

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions
2520VQ Series
Dimensions in millimeters (inches)
.375 UNC-2B OR M10 THD.
19,05 (.75) DEEP 4 HOLES
63,5 (2.50)
INLET CONN.

4-BOLT PORT CONNECTION PADS ARE


FOR USE WITH 4-BOLT FLANGES.
SEE PAGE 119 FOR SELECTION.

101,6
101,5
(4.000)
(3.998)

OPTIONAL STRAIGHT THREAD CONNECTION


1.0625-12 UN-2B THREAD
FOR SAE HYD. FITTINGS

OPTIONAL STRAIGHT
THREAD CONNECTION
1.3125-12 UN2B
THREAD FOR SAE HYD.
FITTINGS
SEE SHAFT OPTIONS
STARTING ON PAGE 30.

12,7
(.50)

.500-13 UNC-2B OR M12


THD. 23,8 (.938) DEEP
4 HOLES

19,1 (.75)
OUTLET
CONN. NO. 2

9,53
(.38)
25,4 (1.00)
OUTLET CONN. NO. 1

.375-16 UNC-2B OR M10 THD.


19,05 (.75) DEEP 4 HOLES

88,1
(3.47)

45
Z

VIEW Z-Z

120,7 (4.75)

101,6
(4.00)

38,1
(1.50)
85,9
(3.38) 84,1
(3.31)

53,8
(2.12)
D
107,7
(4.24)
Z

B
11,9
R.
(.47)

146,1(5.75)

76,2
(3.00)

76,2
(3.00)

HEIGHT OF
STRAIGHT
THREAD
CONNECTION

252,5
(9.94)

53,8
(2.12)

A
107,7
(4.24)

174,8
(6.88)

14,2 (.56) 2 HOLES

3520VQ Series
15,7
(.62)

Dimensions in millimeters (inches)


.625 UNC-2B OR M16 THD.
28,5 (1.125) DEEP 4 HOLES

127,0

4-BOLT PORT CONNECTION PADS ARE


FOR USE WITH 4-BOLT FLANGES.
SEE PAGE 119 FOR SELECTION.

126,9
(5.000)
(4.998)

OPTIONAL STRAIGHT THREAD CONNECTION


1.0625-12 UN-2B THREAD
FOR SAE HYD. FITTINGS

SEE SHAFT OPTIONS STARTING


ON PAGE 30.

76.2 (3.00)
INLET CONN.
.375-16 UNC-2B OR M10 THD.
19,05 (.75) DEEP 4 HOLES
.437-14 UNC-2B OR M12 THD
22,2 (.875) DEEP 4 HOLES

9,7
(.38)
31,8 (1.25)
OUTLET CONN. NO. 1

VIEW Z-Z
C

19,1 (.75)
OUTLET
CONN. NO. 2

45
Z

114,3
(4.50)

212,9
(8.38)

38,1
(1.50)
88,9
(3.50) 82,6
(3.25)

Z
B
69,9
R.
(2.75)

276,6
(10.89)
99,6
(3.92)

181,1

(7.13)

D
76,2
(3.00)
A

www.Go2Hydraulics.com

17,5 (.69) 2 HOLES

147.6 (5.81)

26

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions
3525VQ Series
Dimensions in millimeters (inches)
.437-14 UNC-2B OR M12
THD. 22,2 (.875) DEEP

4-BOLT PORT CONNECTION PADS ARE


FOR USE WITH 4-BOLT FLANGES.
SEE PAGE 119 FOR SELECTION.

9,53
(.375)

.625-11 UNC-2B OR M16


THD. 28,5 (1.125) DEEP

OPTIONAL STRAIGHT
THREAD CONNECTION
1.3125-12 UN-2B THREAD
FOR SAE HYD. FITTINGS

127,0
126,9
(5.000)
(4.998)
SEE SHAFT OPTIONS STARTING
ON PAGE 30.
76.2 (3.00)
INLET CONN.
31,8 (1.25)
OUTLET CONN. NO. 1

.375-16 UNC-2B OR M10 THD


16,7 (.66) DEEP

58,7 R.
(2.31)
C

VIEW Z-Z

25,4 (1.00)
OUTLET CONN.
NO. 2

12,7 R.
(.50)

109,5
(4.31)

15,7
(.62)
82,6
(3.25)

293,9
(11.57)
114,3
(4.50)

212,9
(8.38)

38,1
(1.50)
88,9
(3.50)

45

B
122,4
(4.82)

181,1
(7.13)

61,2
(2.41)

61,2
(2.41)

74,7
(2.94)
81,0
(3.19)

122,4
(4.82)
A

147.6 (5.81)
17,5 (.69) 2 HOLES
HEIGHT OF STR. THD. CONNECTION

4520VQ Series

.500-13 UNC-2B OR M12 THD.


23,8 (.938) DEEP 4 HOLES

Dimensions in millimeters (inches)

.625-11 UNC-2B OR M16 THD.


31,7 (1.25) DEEP 2 HOLES
4-BOLT PORT CONNECTION
PADS ARE FOR USE WITH
4-BOLT FLANGES. SEE PAGE
119 FOR SELECTION.

88,9 (3.50)
INLET CONN.

OPTIONAL STRAIGHT
THREAD CONNECTION
1.0625-12 UN-2B THREAD
FOR SAE HYD. FITTINGS
SEE SHAFT OPTIONS STARTING
ON PAGE 30.

19,1 (.75)
OUTLET CONN.
NO. 2

38,1 (1.50)
OUTLET CONN. NO. 1

306,8
(12.08)

Z
VIEW Z-Z
C

79,2
(3.12)

12,7
(.50)

.375-16 UNC-2B OR M10 THD.


19,05 (.75) DEEP 4 HOLES

162,1
(6.38)
81,0
(3.19)

15,7
(.62)

119,9
(4.72)

119,4
(4.70)

42,9
(1.69)

127,0
126,9
(5.000)
(4.998)

212,9
(8.38)

93,7
(3.69)
102,4
(4.03)

45
D

B
76,2 84,1
(3.00) (3.31)
A

www.Go2Hydraulics.com

181,1

(7.13)
17,5 (.69) 2 HOLES

147.6 (5.81)

27

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

4525VQ Series
Dimensions in millimeters (inches)
4-BOLT PORT CONNECTION PADS ARE
FOR USE WITH 4-BOLT FLANGES. SEE
PAGE 119 FOR SELECTION.

OPTIONAL STRAIGHT
THREAD CONNECTION
1.3125-12 UN-2B THREAD
FOR SAE HYD. FITTINGS

38,1 (1.50)
OUTLET CONN. NO. 1
.625-11 UNC-2B OR M16 THD.
31,7 (1.25) DEEP 4 HOLES

127,0
126,9
(5.000)
(4.998)

162,1
(6.38)

81,0
(3.19)

25,4 (1.00)
OUTLET CONN.
NO. 2

119,4
(4.70)

135,9
(5.35)

Z
84,1
(3.31)

79,2
(3.12)

.500-13 UNC-2B OR M12 THD.


23,8 (.938) DEEP 4 HOLES

329,9
(12.99)

15,7
(.62)

88,9 (3.50)
INLET CONN.

.375-16 UNC-2B OR M10 THD.


16,6 (.656) DEEP 4 HOLES
VIEW Z-Z

SEE SHAFT OPTIONS STARTING


ON PAGE 30.

93,7
(3.69)

42,9
(1.69)

212,9
(8.38)

102,4
(4.03)

45

74,7
(2.94)

181,1

(7.13)

79,2
(3.12)
HEIGHT OF STRAIGHT
THREAD CONNECTION

17,5 (.69) 2 HOLES


FOR MOUNTING

12,7
(.50)

147.6 (5.81)

4535VQ Series
Dimensions in millimeters (inches)
.500-13UNC-2B OR M12 THD.
23,8 (.94) DEEP 4 HOLES

.437-14 UNC-2B OR M12 THD.


22.3 (.88) DEEP 4 HOLES

SEE SHAFT OPTIONS STARTING


ON PAGE 30.

.625-11 UNC-2B OR M16 THD.


31,7 (1.25) DEEP 4 HOLES

127,0
126,9
(5.000)
(4.998)

PORT CONNECTION PADS ARE


FOR USE WITH 4-BOLT FLANGES.
SEE PAGE 119 FOR SELECTION.

31,8 (1.25)
OUTLET CONN. NO. 2
101,6 (4.00)
INLET CONN.

15,7
(.62)

38,1 (1.50)
OUTLET CONN. NO. 1
C
162,1
(6.38)

353,1 (13.90)
148,3
(5.84)

81,0
(3.19)

133,4
(5.25)

42,9
(1.69)
102,4
(4.03)

101,6
(4.00)
B

212,9
(8.38)

93,7
(3.69)

D
84,1
(3.31)
A

www.Go2Hydraulics.com

17,5 (.69)
2 HOLES
12,7
(.50)

181,1
(7.13)

147.6 (5.81)

28

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions

Pumps with flow control cover


Dimensions in millimeters (inches)
OUTLET CONNECTION NO. 2
.750-16 UNF-2B THD.

Model
series
A
2520VQF 265,9
(10.47)
3520VQF 289,8
(11.41)
4520VQF 320,3
(12.61)

Dimensions
B
C
D
108,7 88,1 101,6
(4.28) (3.47) (4.00)
120,1 99,6 114,3
(4.73) (3.92) (4.50)
140,5 119,9 119,4
(5.53) (4.72) (4.70)

E
38,1
(1.50)
38,1
(1.50)
42,9
(1.69)

INLET
CONNECTION

OUTLET CONNECTION NO. 1

TANK CONNECTION
.875-14 UNF-2B THD.
A

45

3,2
(.125)

23,0
(.906)

98,6
(3.88)

114,3
(4.50)

Note: For installation dimensions and


performance data of basic pump series,
refer to preceding pages.
INLET CONNECTION

Pumps with priority valve cover


Dimensions in millimeters (inches)
Model
series
A
2520VQP 276,6
(10.89)
3520VQP 300,7
(11.84)
4520VQP 331,0
(13.03)

Dimensions
B
C
113,0 101,6
(4.45) (4.00)
124,5 114,3
(4.90) (4.50)
144,8 119,4
(5.70) (4.70)

OUTLET
CONNECTION
NO. 1

SECONDARY OUTLET PORT


.875-14 UNF-2B THD PORT
MACHINED TO .62 TUBE SIZE
PER SAE SPEC FOR STRAIGHT
THD O RING BOSS.

D
38,1
(1.50)
38,1
(1.50)
42,9
(1.69)
A

124,0
(4.88)

62,0
(2.44)

56,4
(2.22)

55,4
(2.18)

#2 PRIMARY OUTLET PORT


.750-16 UNF-2B THD. PORT MACHINED
TO .50 TUBE SIZE PER SAE SPEC.
FOR STRAIGHT THREAD O RING BOSS
16,0 (.63)
16,0 (.63)
TANK PORT FOR PRESSURE RELIEF
OF PRIMARY OUTLET PORT
.750-16 UNF-2B THD. PORT MACHINED
TO .50 TUBE SIZE PER SAE SPEC.
FOR STRAIGHT THREAD O RING BOSS.

www.Go2Hydraulics.com

29

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Optional Shafts

Splined Shafts

Dimensions in millimeters (inches)


B

See spline data table below.


C

Pump

2520VQ
2520VQ,
2520VQF,
2 20VQP
2520VQP
3520VQ,
3520VQF,
3520VQP
3520VQP,
3525VQ
4520VQ,
4520VQF
4520VQF,
4520VQP,,
4525VQ
4525VQ,
4535VQ

Shaft
Code

Spline Data
(See below.)

11

44,5 (1.75)

9,53 (.375)

11,1 (.437)

4,1 (.16)

27,8 (1.09)

123

44,5 (1.75)

9,53 (.375)

15,7 (.62)

4,1 (.16)

27,8 (1.09)

297

41,1 (1.62)

9,53 (.375)

7,9 (.31)

6,4 (.25)

27,8 (1.09)

11

58,7 (2.31)

9,53 (.375)

11,1 (.437)

6,4 (.25)

35,1 (1.38)

123

58,7 (2.31)

9,53 (.375)

15,2 (.60)

5,5 (.21)

35,1 (1.38)

297

55,5 (2.19)

12,7 (.500)

7,9 (.31)

5,5 (.21)

35,1 (1.38)

11

61,9 (2.44)

12,7 (.500)

14,3 (.565)

9,7 (.38)

39,6 (1.56)

130

61,9 (2.44)

12,7 (.500)

15,2 (.60)

9,9 (.39)

40,4 (1.59)

297

55,5 (2.19)

12,7 (.500)

7,9 (.31)

6,4 (.25)

39,6 (1.56)

Spline Data Table


(Involute splines from above chart)
Spline Data
Reference

Number of
Teeth

Pitch

Major Diameter

Form Diameter

Minor Diameter

Minor Diameter

13

16/32

22,17 (.873)
22,15 (.872)

19,03 (.749)

18,16 (.715)

Major dia. fit

13

16/32

21,8 (.858)
21,6 (.852)

19,03 (.749)

18,16 (.715)

Side fit

14

12/24

31,70 (1.248)
31,67 (1.247)

27,4 (1.08)

26,42 (1.040)

Major dia. fit

14

12/24

31,2 (1.229)
31,1 (1.223)

27,4 (1.08)

26,42 (1.040)

Side fit

www.Go2Hydraulics.com

30

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Optional Shafts

Straight Key Shafts

Dimensions in millimeters (inches)


F
E

D
1,5 (.06) x 45
C
A
Pump

2520VQ,
2520VQF,
2520VQP

3520VQ
3520VQ,
3520VQF,
3520VQP,
3525VQ
Q

4520VQ,
4520VQF,
4520VQP,
4525VQ
4525VQ,
4535VQ

Shaft
Code

F key width
x length

58,7 (2.31)

9,53 (.375)

11,1 (.435)

22,23 (.875)
22,20 (.874)

24,5 (.966)
24,4 (.961)

4,75 (.187)
x 32 (1.25)

86

77,7 (3.06)

9,53 (.375)

11,1 (.435)

25,37 (.999)
25,35 (.998)

28,3 (1.11)
28,1 (1.10)

6,35 (.250)
x 50,8 (2.00)

203

77,7 (3.06)

9,53 (.375)

7,9 (.31) 

25,40 (1.00)
25,35 (.998)

28,20 (1.11)
27,94 (1.10)

6,35 (.250)
x 49,2 (1.938)

73,2 (2.88)

9,53 (.375)

11,1 (.435)

31,75 (1.250)
31,70 (1.248)

35,36 (1.39)
34,10 (1.38)

7,94 (.313)
x 38,1 (1.50)

86

85,9 (3.38)

9,53 (.375)

11,1 (.435)

34,90 (1.374)
34,87 (1.373)

38,6 (1.52)
38,3 (1.51)

7,92 (.312)
x 54 (2.13)

203

84,1 (3.31)

12,7 (.500)

7,9 (.31) 

34,90 (1.374)
34,87 (1.373)

38,6 (1.52)
38,3 (1.51)

7,92 (.312)
x 54 (2.125)

62,0 (2.44)

12,7 (.500)

14,22 (.560)

31,75 (1.250)
31,70 (1.248)

35,36 (1.39)
34,10 (1.38)

7,92 (.312)
x 28,5 (1.12))

86

87,4 (3.44)

12,7 (.500)

14,22 (.560)

38,07 (1.499)
38,05 (1.498)

42,4 (1.67)
42,1 (1.66)

9,53 (.375)
x 50,8 (2.00)

203

90,4 (3.56)

12,7 (.500)

7,9 (.31) 

38,07 (1.499)
38,05 (1.498)

42,4 (1.67)
42,1 (1.66)

9,53 (.375)
x 57,1 (2.25)

 Shaft shoulder inside recess in pilot.

www.Go2Hydraulics.com

31

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
Shaft End Pumps
2520VQ Double Pumps &
2520VQV10 Triple Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

CODE 12 & 17 PUMPS

bar (psi) CODE


170 (45)

DELIVERY L/min (USgpm)

121 (32)
106 (28)

7 (100)
70 (1000)
12
140 (2000)
210 (3000)

91 (24)
76 (20)
61 (16)
45 (12)

7 (100)
70 (1000)
21
140 (2000)
210 (3000)

151 (40)
DELIVERY L/min (USgpm)

7 (100)
70 (1000)
17
140 (2000)
210 (3000)

136 (36)

30 (8)

133 (35)

7 (100)
70 (1000)
14
140 (2000)
210 (3000)

114 (30)
95 (25)
76 (20)
57 (15)
38 (10)
19 (5)

15 (4)
0

bar (psi) CODE

CODE 14 & 21 PUMPS

151 (40)

0
400
400

800

1200

1600

2000

2400

800

1200

1600

2000

2400

2800

2800

74,6 (100)
67,1 (90)

210 (3000) 17

44,7 (60)

210 (3000) 12

37,3 (50)

140 (2000) 17

29,8 (40)

140 (2000) 12

INPUT kW (hp)

INPUT kW (hp)

52,2 (70)

52,2 (70)
210 (3000) 14
140 (2000) 21

44,7 (60)
37,3 (50)

140 (2000) 14
29,8 (40)
70 (1000) 21
70 (1000) 14

22,4 (30)

22,4 (30)
70 (1000) 17
70 (1000) 12

14,9 (20)

14,9 (20)
7,5 (10)

7,5 (10)
0
400

210 (3000) 21

59,7 (80)

59,7 (80)

7 (100) 17
7 (100) 12
800

1200

1600

SPEED r/min

www.Go2Hydraulics.com

2000

2400

2800

0
400

7 (100) 21
7 (100) 14
800

1200

1600

2000

2400

2800

SPEED r/min

32

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
Shaft End Pumps
3520VQ & 3525VQ Double Pumps,
352*VQV10Triple Pumps,
3525VQT Double Thru-drive Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

CODE 25 & 35 PUMPS

273 (72)

bar (psi) CODE

288 (76)

7 (100)

273 (72)

257 (68)

CODE 30 & 38 PUMPS

bar (psi) CODE


7 (100)
70 (1000)

242 (64)

257 (68)

70 (1000) 35
140 (2000)
210 (3000)

227 (60)

242 (64)

197 (52)

7 (100)

212 (56)

182 (48)

70 (1000) 35
140 (2000)
210 (3000)

197 (52)

167 (44)
151 (40)
136 (36)
121 (32)
106 (28)

167 (44)
151 (40)
136 (36)
121 (32)
106 (28)

76 (20)

91 (24)

61 (16)

76 (20)

45 (12)

61 (16)

30 (8)

45 (12)

15 (4)

30 (8)
800

1200

1600

2000

2400

15 (4)
400

2800

70 (1000) 30
140 (2000)
210 (3000)

182 (48)

91 (24)

0
400

7 (100)

227 (60)

DELIVERY L/min (USgpm)

DELIVERY L/min (USgpm)

212 (56)

38

140 (2000)
210 (3000)

800

1200

1600

2000

2400

2800

111,9 (150)
104,4 (140)

104,4 (140)
210 (3000) 35

96,9 (130)
89,5 (120)

89,5 (120)

82,0 (110)

82,0 (110)
210 (3000) 25

INPUT kW (hp)

67,1 (90)

140 (2000) 35

59,7 (80)
52,2 (70)

140 (2000) 25

44,7 (60)
37,3 (50)

210 (3000) 30

74,6 (100)
INPUT kW (hp)

74,6 (100)

210 (3000) 38

96,9 (130)

140 (2000) 38

67,1 (90)

140 (2000) 30

59,7 (80)
52,2 (70)
44,7 (60)
37,3 (50)

70 (1000) 38
70 (1000) 30

70 (1000) 35
29,8 (40)

29,8 (40)
70 (1000) 25

22,4 (30)

7,5 (10)
0
400

22,4 (30)
14,9 (20)

14,9 (20)
7 (100) 35
7 (100) 25
800

1200
1600
2000
SPEED r/min

www.Go2Hydraulics.com

2400

2800

7 (100) 38
7 (100) 30

7,5 (10)
0
400

800

1200

1600

2000

2400

2800

SPEED r/min

33

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Shaft End Pumps


4520VQ, 4525VQ & 4535VQ Double
Pumps, 45*5VQV10 Triple Pumps,
4525VQT Double Thru-drive Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

bar (psi) CODE

CODE 42 & 60 PUMPS


416 (110)

7 (100)

398 (105)

322 (85)

322 (85)

303 (80)

303 (80)

284 (75)
7 (100)

284 (75)

70 (1000)
265 (70)

140 (2000)
175 (2500)

246 (65)

42

227 (60)
208 (55)
189 (50)
170 (45)

70 (1000) 50
140 (2000)
175 (2500)

265 (70)
246 (65)
227 (60)
208 (55)
189 (50)
170 (45)
151 (40)

151 (40)

133 (35)

133 (35)

114 (30)

114 (30)

95 (25)

95 (25)

76 (20)

76 (20)

57 (15)

57 (15)

38 (10)

38 (10)
400

7 (100)

341 (90)

341 (90)

DELIVERY L/min (USgpm)

DELIVERY L/min (USgpm)

360 (95)

140 (2000)
175 (2500)

360 (95)

bar (psi) CODE

CODE 50 PUMPS

70 (1000) 60

379 (100)

800

1200

1600

2000

2400

19 (5)
400

2800

800

1200

1600

2000

2400

2800

134,2 (180)
119,3 (160)

104,4 (140)

140 (2000) 60

104,4 (140)

175 (2500) 50

89,5 (120)

175 (2500) 42

89,5 (120)

140 (2000) 50

74,6 (100)

140 (2000) 42

59,7 (80)

70 (1000) 60

44,7 (60)

INPUT kW (hp)

INPUT kW (hp)

175 (2500) 60
119,3 (160)

74,6 (100)
59,7 (80)
70 (1000) 50

44,7 (60)

70 (1000) 42
29,8 (40)

29,8 (40)

14,9 (20)
0
400

7 (100) 60
7 (100) 42
800

1200

1600

2000

SPEED r/min

www.Go2Hydraulics.com

2400

2800

14,9 (20)
0
400

7 (100) 50
800

1200

1600

2000

2400

2800

SPEED r/min

34

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
Cover-end Pumps of
2520VQ Double Pumps &
Center Pumps of 2520VQV10
Triple Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

bar (psi) CODE

CODE 12 & 14 PUMPS


136 (36)
129 (34)

7 (100)
70 (1000) 14
140 (2000)

121 (32)
114 (30)

bar (psi) CODE

CODE 5, 8 & 11 PUMPS


106 (28)

DELIVERY L/min (USgpm)

83 (22)
76 (20)
68 (18)
61 (16)
53 (14)
45 (12)
38 (10)

7 (100)
70 (1000)
140 (2000)
210 (3000)

7 (100)
70 (1000)
140 (2000)
210 (3000)

98 (26)
DELIVERY L/min (USgpm)

7 (100)
70 (1000) 11
140 (2000)
210 (3000)

91 (24)

91 (24)
83 (22)
76 (20)
68 (18)
61 (16)
53 (14)
45 (12)
38 (10)

30 (8)

30 (8)

23 (6)

23 (6)

15 (4)

15 (4)

8 (2)

8 (2)

0
400

800

1200

1600

2000

2400

37,3 (50)

0
400

2800

800

1200

1600

2000

2400

2800

210 (3000) 11

33,6 (45)

33,6 (45)

29,8 (40)

29,8 (40)
210 (3000) 8
140 (2000) 11

26,1 (35)
22,4 (30)

210 (3000)
140 (2000)

18,6 (25)

5
8

14,9 (20)
70 (1000) 11
140 (2000) 5

11,2 (15)
7,5 (10)

70 (1000)

70 (1000)

3,7 (5)
0
400

800

1200
1600
2000
SPEED r/min

www.Go2Hydraulics.com

2400

2800

7 (100) 11
7 (100) 8
7 (100) 5

140 (2000) 14
160 (2300) 12

26,1 (35)
INPUT kW (hp)

INPUT kW (hp)

7 (100)
70 (1000)
140 (2000) 12
160 (2300)

106 (28)

98 (26)

70 (1000) 12

22,4 (30)
18,6 (25)
14,9 (20)

70 (1000) 14
70 (1000) 14

11,2 (15)
7,5 (10)
3,7 (5)
0
400

7 (100) 14
7 (100) 12
800

1200
1600
2000
SPEED r/min

2400

2800

35

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Cover-end Pumps of 3520VQ Double


Pumps, Center Pumps of 3520VQV10
Triple Pumps, Rear Pumps of 3525VQT
Double Thrudrive Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

CODE 12 & 14 PUMPS

bar (psi) CODE

136 (36)
129 (34)
121 (32)
CODE 5, 8 & 11 PUMPS

114 (30)

bar (psi) CODE

91 (24)

7 (100)
70 (1000) 11
140 (2000)
210 (3000)

DELIVERY L/min (USgpm)

83 (22)
76 (20)

7 (100)
70 (1000)
140 (2000)
210 (3000)

68 (18)
61 (16)

53 (14)
7 (100)
70 (1000)
140 (2000)
210 (3000)

45 (12)
38 (10)

DELIVERY L/min (USgpm)

98 (26)

98 (26)

83 (22)
76 (20)
68 (18)
61 (16)
53 (14)

5
45 (12)
38 (10)

23 (6)

30 (8)

15 (4)

23 (6)

8 (2)

15 (4)
800

1200

1600

2000

2400

7 (100)
70 (1000) 12
140 (2000)
160 (2300)

91 (24)

30 (8)

0
400

7 (100)
70 (1000) 12
140 (2000)

106 (28)

8 (2)
400

2800

800

1200

1600

2000

2400

2800

37,3 (50)
210 (3000) 11

29,8 (40)

29,8 (40)

26,1 (35)

26,1 (35)
210 (3000) 8
140 (2000) 11

22,4 (30)
18,6 (25)

210 (3000)
140 (2000)

14,9 (20)
11,2 (15)

140 (2000) 5
70 (1000) 11
140 (2000) 8
70 (1000) 5

7,5 (10)
3,7 (5)
0
400

5
8

800

1200
1600
2000
SPEED - r/min

www.Go2Hydraulics.com

2400

2800

7 (100) 11
7 (100) 8
7 (100) 5

INPUT kW (hp)

INPUT kW (hp)

33,6 (45)

140 (2000) 14
160 (2300) 12
140 (2000) 12

22,4 (30)
18,6 (25)
14,9 (20)

70 (1000) 14
70 (1000) 12

11,2 (15)
7,5 (10)
3,7 (5)
0
400

7 (100) 14
7 (100) 12
800

1200
1600
2000
SPEED - r/min

2400

2800

36

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
Cover-end Pumps of
3525VQ Double Pumps &
Center Pumps of 3525VQV10
Triple Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

CODE 14 & 21 PUMPS

bar (psi) CODE

167 (44)
CODE 12 & 17 PUMPS

7 (100)
70 (1000) 17
140 (2000)
210 (3000)

121 (32)
106 (28)

7 (100)
70 (1000) 12
140 (2000)
210 (3000)

91 (24)
76 (20)
61 (16)

DELIVERY L/min (USgpm)

136 (36)
DELIVERY L/min (USgpm)

151 (40)

bar (psi) CODE

136 (36)

106 (28)
91 (24)

30 (8)
1600

2000

2400

15 (4)

2800

14

61 (16)

30 (8)
1200

7 (100)
70 (1000)
140 (2000)
210 (3000)

76 (20)

45 (12)

800

21

121 (32)

45 (12)

15 (4)
400

7 (100)
70 (1000)
140 (2000)
210 (3000)

400

800

1200

1600

2000

2400

2800

67,1 (90)
59,7 (80)
52,2 (70)

37,3 (50)
29,8 (40)

140 (2000) 12

22,4 (30)

INPUT kW (hp)

INPUT kW (hp)

210 (3000) 12
140 (2000) 17

44,7 (60)
37,3 (50)

70 (1000) 12

14
21

140 (2000)

14

22,4 (30)

70 (1000)

21

14,9 (20)

70 (1000)

14

7 (100)
7 (100)

21
14

7,5 (10)

7,5 (10)
0
400

210 (3000)
140 (2000)

29,8 (40)

70 (1000) 17
14,9 (20)

21

52,2 (70)

210 (3000) 17

44,7 (60)

210 (3000)

800

1200

www.Go2Hydraulics.com

1600
2000
SPEED - r/min

2400

2800

7 (100) 17
7 (100) 12

0
400

800

1200
1600
2000
SPEED - r/min

2400

2800

37

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Coverend Pumps of
4520VQ Double Pumps &
Center Pumps of 4520VQV10
Triple Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

CODE 12 & 14 PUMPS

bar (psi) CODE

106 (28)
7 (100)
70 (1000)
140 (2000)

98 (26)
CODE 5, 8 & 11 PUMPS

91 (24)

bar (psi) CODE

68 (18)
61 (16)
53 (14)
45 (12)
38 (10)
30 (8)

7 (100)
70 (1000)
140 (2000)
210 (3000)

11

7 (100)
70 (1000)
140 (2000)
210 (3000)

7 (100)
70 (1000)
140 (2000)
210 (3000)

DELIVERY L/min (USgpm)

DELIVERY L/min (USgpm)

76 (20)

61 (16)
53 (14)
45 (12)
38 (10)
30 (8)
23 (6)
15 (4)

800

1200

1600

2000

2400

8 (2)
400

2800

210 (3000)

1200

1600

2000

2400

26,1 (35)

14,9 (20)
11,2 (15)
7,5 (10)
3,7 (5)
800

1200

www.Go2Hydraulics.com

1600
2000
SPEED - r/min

2400

210 (3000)
140 (2000)

8
11

210 (3000)
140 (2000)
140 (2000)
70 (1000)
70 (1000)
70 (1000)
7 (100)
7 (100)
7 (100)
2800

5
8
5
11
8
5
11
8
5

22,4 (30)
INPUT kW (hp)

18,6 (25)

0
400

800

2800

11

26,1 (35)
22,4 (30)

12

68 (18)

15 (4)

29,8 (40)

INPUT kW (hp)

76 (20)

23 (6)

8 (2)
400

7 (100)
70 (1000)
140 (2000)
210 (3000)

83 (22)

83 (22)

14

18,6 (25)

140 (2000)
160 (2300)

14
12

140 (2000)

12

70 (1000)
70 (1000)

14
12

7 (100)
7 (100)

14
12

14,9 (20)
11,2 (15)
7,5 (10)
3,7 (5)
0
400

800

1200

1600
2000
SPEED - r/min

2400

2800

38

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
Cover-end Pumps of 4525VQ Double
Pumps, Center Pumps of 4525VQV10
Triple Pumps, Rear Pumps of 4525VQT
Double Thrudrive Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

CODE 14 & 21 PUMPS

151 (40)

bar (psi) CODE


7 (100)
70 (1000) 21
140 (2000)
210 (3000)

CODE 12 & 17 PUMPS

DELIVERY L/min (USgpm)

121 (32)

bar (psi) CODE


7 (100)
70 (1000)
140 (2000)
210 (3000)
7 (100)
70 (1000)
140 (2000)
210 (3000)

106 (28)
91 (24)
76 (20)
61 (16)

17

12

45 (12)

DELIVERY L/min (USgpm)

136 (36)

30 (8)
15 (4)
400

121 (32)
106 (28)

7 (100)
70 (1000) 14
140 (2000)
210 (3000)

91 (24)
76 (20)
61 (16)
45 (12)
30 (8)

800

1200

1600

2000

2400

15 (4)
400

2800

800

1200

1600

2000

2400

2800

59,7 (80)
52,2 (70)
17

29,8 (40)

210 (3000)
140 (2000)

12
17

22,4 (30)

140 (2000)

12

14,9 (20)

70 (1000)
70 (1000)

17
12

INPUT kW (hp)

37,3 (50)

7,5 (10)

7 (100)
7 (100)
800

1200

1600

2000

SPEED - r/min

www.Go2Hydraulics.com

2400

2800

17
12

INPUT kW (hp)

210 (3000)

44,7 (60)

0
400

210 (3000) 21

52,2 (70)
44,7 (60)

210 (3000) 14
140 (2000) 21

37,3 (50)
29,8 (40)

140 (2000) 14
22,4 (30)
70 (1000) 21
14,9 (20)

70 (1000) 14

7,5 (10)
0
400

7 (100) 21
7 (100) 14
800

1200

1600

2000

2400

2800

SPEED - r/min

39

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Cover-end Pumps of
4535VQ Double Pumps &
Center Pumps of 4535VQV10
Triple Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

CODE 30 & 38 PUMPS


CODE 25 & 35 PUMPS

242 (64)

7 (100)

7 (100)

242 (64)

70 (1000)
35
140 (2000)
210 (3000)

227 (60)

70 (1000)
38
140 (2000)
210 (3000)

bar (psi) CODE

227 (60)
212 (56)

182 (48)
7 (100)
70 (1000) 25
140 (2000)
210 (3000)

151 (40)
136 (36)
121 (32)
106 (28)

DELIVERY L/min (USgpm)

DELIVERY L/min (USgpm)

197 (52)

167 (44)

212 (56)

7 (100)

197 (52)

70 (1000) 30
140 (2000)
210 (3000)

182 (48)
167 (44)
151 (40)
136 (36)
121 (32)
106 (28)

91 (24)

91 (24)

76 (20)

76 (20)

61 (16)

61 (16)

45 (12)

45 (12)

30 (8)
400

800

1200

1600

2000

2400

bar (psi) CODE

257 (68)

30 (8)
400

2800

800

1200

1600

2000

2400

96,9 (130)

82,0 (110)

82,0 (110)

74,6 (100)

74,6 (100)

67,1 (90)

210 (3000) 25

67,1 (90)

59,7 (80)

140 (2000) 35

59,7 (80)

52,2 (70)
140 (2000) 25

44,7 (60)
37,3 (50)
29,8 (40)
22,4 (30)

210 (3000) 30

140 (2000) 38
52,2 (70)

140 (2000) 30

44,7 (60)
37,3 (50)

70 (1000) 35

29,8 (40)

70 (1000) 25

22,4 (30)

70 (1000) 38
70 (1000) 30

14,9 (20)

14,9 (20)
7,5 (10)
0
400

210 (3000) 38

89,5 (120)

210 (3000) 35

INPUT kW (hp)

INPUT kW (hp)

89,5 (120)

2800

7 (100) 35
7 (100) 25
800

www.Go2Hydraulics.com

1200
1600
2000
SPEED - r/min

2400

2800

7,5 (10)
0
400

7 (100) 38
7 (100) 30
800

1200

1600
2000
SPEED - r/min

2400

2800

40

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
Controlled Flow
Integral Valves (cover end)
Models 2520VQF, 3520VQF &
4520VQF Double Pumps
Performance Constants:
SAE 10W fluid @ 82C (180F)
Pump inlet @ 0 psig (14.7 psia)

Curves shown for 70 bar (1000 psi)


operating pressure. Controlled flow
varies slightly at other pressures.
CODE 8 PUMP
76 (20)

68 (18)

68 (18)

61 (16)
53 (14)
L/min (USgpm)
45 (12)
38 (10)

45 (12)
38 (10)

23 (6)

30 (8)
27 (7)
23 (6)

15 (4)

15 (4)

30 (8)

8 (2)

8 (2)
0
600 800

DELIVERY L/min (USgpm)

DELIVERY L/min (USgpm)

CODE 5 PUMP
76 (20)

1200

1600

61 (16)
L/min (USgpm)

53 (14)

45 (12)

45 (12)

38 (10)

38 (10)

30 (8)
27 (7)
23 (6)

30 (8)
23 (6)

15 (4)

15 (4)

8 (2)

8 (2)
0
600 800

2000
2400 2700
PUMP SPEED - r/min

1200

1600

2000
2400 2700
PUMP SPEED - r/min

CODE 11 PUMP

CODE 12 PUMP
121 (32)

106 (28)
91 (24)
76 (20)
L/min (USgpm)
45 (12)

61 (16)

38
30
27
23
15
8

45 (12)
30 (8)
15 (4)
0
600 800

1200

1600

(10)
(8)
(7)
(6)
(4)
(2)

DELIVERY L/min (USgpm)

DELIVERY L/min (USgpm)

121 (32)

106 (28)
91 (24)
76 (20)
L/min
45
38
30
27
23
15
8

61 (16)
45 (12)
30 (8)
15 (4)
0
600 800

2000
2400 2700
PUMP SPEED - r/min

1200

1600

(USgpm)
(12)
(10)
(8)
(7)
(6)
(4)
(2)

2000
2400 2700
PUMP SPEED - r/min

RELIEF VALVE PRESSURE


OVERRIDE CHARACTERISTICS
(ALL SERIES)
175 (2500)

DELIVERY L/min (USgpm)

106 (28)
91 (24)
76 (20)
L/min
45
38
30
27
23
15
8

61 (16)
45 (12)
30 (8)
15 (4)
0
600 800

1200

1600

2000
2400 2700
PUMP SPEED - r/min

(USgpm)
(12)
(10)
(8)
(7)
(6)
(4)
(2)

PRESSURE - bar (psi)

CODE 14 PUMP
121 (32)

140 (2000)

100 (1500)

70 (1000)

35 (500)

18,0
(5)

37,9
(10)

56,8
(15)

75,7
(20)

94,6
25

113,6
(30)

VOLUME - L/min (USgpm)

www.Go2Hydraulics.com

41

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Speed Correction Curves

Maximum operating speed


correction factors based on
pump inlet conditions.
4520VQ & 4535VQ Series

2520VQ Series
0,14
0,07
0,10
bar 0,17

0,07

0,14

0,21

0,28

0,34

bar

bar

0,14
0,07
0,17
0,10

1.12

SPEED RATING
CORRECTION
FACTOR

1.12
1.10

1.10

1.08

1.08

1.06

1.06

1.04

1.04

1.02
5

in. Hg

VACUUM

0,21

0,28

0,34

bar

0.98

1.0

2
3
4
5
SUPERCHARGE PRESSURE

psi

SPEED RATING
CORRECTION
FACTOR

1.02
5

VACUUM

2
1.0
0.98

0.96

0.96

0.94

0.94

0.92

0.92

0.90

2
3
4
5
SUPERCHARGE PRESSURE

psi

0.90

0.88

0.88

0.86

0.86
Maximum operating speeds shown on performance curves are for pumps
operating at 0 psi inlet condition. To compute maximum operating speeds
at other inlet conditions use the appropriate speed rating correction factor
shown in the curve above.

Maximum operating speeds shown on performance curves are for pumps


operating at 0 psi inlet condition. To compute maximum operating speeds
at other inlet conditions use the appropriate speed rating correction factor
shown in the curve above.
EXAMPLE:

0,14

1.14

1.14

in. Hg

0,07

Max. Speed @ 0 psi Inlet


Correction Factor @ 5 in. Hg
Max. Speed @ 5 in. Hg Inlet

2700 r/min
X .93
2511 r/min

EXAMPLE:

Max. Speed @ 0 psi Inlet


Correction Factor @ 5 in. Hg
Max. Speed @ 5 in. Hg Inlet

2200 r/min
X .91
2002 r/min

Pump inlet suction should not exceed 5 in. Hg vacuum. Positive pressure
on inlet should not exceed 1.4 bar (20 psi).

Pump inlet suction should not exceed 5 in. Hg vacuum. Positive pressure
on inlet should not exceed 1.4 bar (20 psi).

3520VQ & 3525VQ Series


bar

0,14
0,07
0,17 0,10

0,07

0,14

0,21

0,28

0,34

bar

1.14
SPEED RATING
CORRECTION
FACTOR

1.12
1.10
1.08
1.06
1.04
in. Hg

1.02
5

VACUUM

2
0.98

1.0

2
3
4
5
SUPERCHARGE PRESSURE

psi

0.96
0.94
0.92
0.90
0.88
0.86

Maximum operating speeds shown on performance curves are for pumps


operating at 0 psi inlet condition. To compute maximum operating speeds
at other inlet conditions use the appropriate speed rating correction factor
shown in the curve above.
EXAMPLE:

Max. Speed @ 0 psi Inlet


Correction Factor @ 5 in. Hg
Max. Speed @ 5 in. Hg Inlet

2500 r/min
X .92
2300 r/min

Pump inlet suction should not exceed 5 in. Hg vacuum. Positive pressure
on inlet should not exceed 1.4 bar (20 psi).

www.Go2Hydraulics.com

42

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Triple Pump Operating Specifications


Maximum speed ratings for triple pumps
are dependent upon V10 ring size. See
chart below for ratings.
Cover-end pump (V10)
delivery/USgpm
@ 1200 rpm and 100 psi

Pressure ratings are shown on page 23


for VQ sections and page 67 for V10
sections.
Maximum Speed - r/min

2520VQSV10

3520VQSV10

3525VQSV10

4525VQSV10

4535VQSV10

1
2
3
4

2700
2700
2700
2700

2500
2500
2500
2500

2200
2200
2200
2200

2200
2200
2200
2200

2700

2500

2200

2200

2200*
2500+
1900*
2200+

2200*
2500+
1900*
2200+

2500
2500
2500
2200*
2500+
2200*
2500+
2200*
2400+
2200

2200

2200

2000*
2200+

2100*
2200+

* With V10 pressure over 70 bar (1000 psi)


+ With V10 pressure to 70 bar (1000 psi)

Typical Performance
For triple pump performance, use
curves listed in this table:
Triple pump
model series

Shaft end
pump

2520VQSV10

25**VQ

Center
pump

Cover end
pump

**20VQ
V10
3520VQSV10

35**VQ
**20VQ
V10

3525VQSV10

35**VQ
**25VQ
V10

4525VQSV10

45**VQ
**25VQ
V10

4535VQSV10

45**VQ
**35VQ
V10

www.Go2Hydraulics.com

Page no.
32
35
73, 76, 77
33
36
73,
33
37
73,
34
39
73,
34
40
73,

76, 77

76, 77

76, 77

76, 77

43

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Model Codes
Triple Pump

F3 Viton seals
Omit if not required.
1

Double pump series

First two numerals in the series denote


shaft end of triple pump; second two
numerals denote the center pump.
2520VQ
3520VQ
3525VQ
3

4525VQ
4535VQ

SAE mounting

S SAE mounting per J 744


4 Single pump series
Cover end pump of triple pump
5

Cover options for V10 pump

10

11

12

13

12

14

17

Splined shaft
297 All series

15

16

17

18

19

Relief valve setting, V10F & V10P

Omit for standard cover.


A 17 bar (250 psi) F 100 bar (1500 psi)
B 35 bar (500 psi) G 121 bar (1750 psi)
C 52 bar (750 psi) H 140 bar (2000 psi)
D 70 bar (1000 psi) J 155 bar (2250 psi)
E 86 bar (1250 psi) K 175 bar (2500 psi)

13
No. 1 outlet port position
Refer to table 2.
14

No. 2 outlet port position


Refer to table 2.

Design
Subject to change. Installation
dimensions remain the same for
designs -20 through -29.
18

15

No. 3 outlet port position


Refer to table 2.
16
Controlled flow rate, V10F & V10P
Omit for standard cover.
3 11 L/min (3 USgpm)
4 15 L/min (4 USgpm)
5 19 L/min (5 USgpm)
6 23 L/min (6 USgpm)
7 27 L/min (7 USgpm)
8 30 L/min (8 USgpm)

19

Shaft rotation
(Viewed from shaft end of pump)
L Left hand (counterclockwise)
R Right hand

S Standard cover
F Integral flow control & relief valve
P Integral priority valve & relief
6

SAE rated flow, shaft-end pump


Refer to table 1.
7

Double pump port connections


A All SAE 4-bolt flange
AM Metric 4-bolt flange
8 SAE rated flow, center pump
Refer to table 1.

Table 1
Rated Flow @ 1200 r/min & 100 psi
Shaftend Shaftend Shaftend
pump
pump
pump
35**
2520
45**
12
14
17
21

25
30
35
38

42
50
60

5
8
11
12
14

No. 3 outlet port connection


Standard Cover
S .750-16 straight thread
Flow Control Cover
T .750-16 straight thread, control port
& tank port.
Priority Valve Cover
K .5625-18 straight thread, primary
port & tank port.
.750-16 straight thread, secondary
port
10

SAE rated flow, cover end pump

Refer to table 1.
11 Shaft seal
S
Double seal
Blank Single seal

www.Go2Hydraulics.com

Table 2
Outlet position code
Position viewed
from cover end
Opposite inlet
135 CCW from inlet
90 CCW from inlet
45 CCW from inlet
Inline with inlet
45 CW from inlet
90 CW from inlet
135 CW from inlet

USgpm
Center
pump
**20

13

Center
pump
**35

12
14
17
21

25
30
35
38

14

No. 1 outlet
A

Center
pump
**25

No. 2 outlet
A (4535 only)
A
B (4535 only)
B
C (4535 only)
C
D (4535 only)
D

Coverend
pump
V10
1
2
3
4
5
6
7

15

No. 3 outlet
A

44

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions
Triple Pumps
A
V10 PORTS

B
OUTLET NO. 2 TURNED
THROUGH 45 FOR ALL
TRIPLE PUMPS EXCEPT
4535VQSV10

OUTLET NO. 3

OUTLET NO. 1

OUTLET NO. 2
INLET

SEE SHAFT
DIMENSIONS,
PAGE 46

WITH BASIC V10


COVER-END PUMP

TANK RETURN

OUTLET NO. 2 TURNED


THROUGH 45 FOR ALL
TRIPLE PUMPS EXCEPT
4535VQSV10

A
B

WITH V10F FLOW


CONTROL/RELIEF VALVE
COVER-END PUMP

OUTLET
A
OUTLET NO. 2 TURNED
THROUGH 45 FOR ALL
TRIPLE PUMPS EXCEPT
4535VQSV10

SECONDARY
OUTLET

WITH V10P PRIORITY


CONTROL/RELIEF VALVE
COVER-END PUMP

PRIMARY
OUTLET
TANK RETURN


V10 cover can be assembled in any of four positions; see model codes, page 44. 4535VQSV10 shown.

Model
series
2520VQSV10
2520VQSV10F
2520VQSV10P
3520VQSV10
3520VQSV10F
3520VQSV10P
3525VQSV10
3525VQSV10F
3525VQSV10P
4525VQSV10
4525VQSV10F
4525VQSV10P
4535VQSV10
4535VQSV10F
4535VQSV10P

1, 2 & 3 USgpm*
A
B
350 (13.78)
363 (14.30)
364 (14.35)
372 (14.66)
386 (15.18)
387 (15.23)
381 (15.00)
394 (15.52)
395 (15.57)
420 (16.53)
433 (17.05)
434 (17.10)
445 (17.50)
458 (18.02)
459 (18.07)

87 (3.43)
105 (4.12)
105 (4.12)
87 (3.43)
105 (4.12)
105 (4.12)
86 (3.40)
104 (4.09)
104 (4.09)
86 (3.40)
104 (4.09)
104 (4.09)
84 (3.31)
102 (4.00)
102 (4.00)

Dimensions mm (in.)
4 & 5 USgpm*
A
B
356 (14.03)
370 (14.55)
371 (14.60)
379 (14.91)
392 (15.43)
393 (15.48)
387 (15.25)
401 (15.77)
402 (15.82)
426 (16.78)
439 (17.30)
441 (17.35)
451 (17.75)
464(18.27)
465 (18.32)

94 (3.68)
111 (4.38)
111 (4.38)
94 (3.68)
111 (4.37)
111 (4.37)
93 (3.65)
110 (4.34)
110 (4.34)
93 (3.65)
110 (4.34)
110 (4.34)
90 (3.56)
108 (4.25)
108 (4.25)

6 & 7 USgpm*
A
B
361 (14.23)
375 (14.75)
376 (14.80)
384 (15.11)
397 (15.63)
398 (15.68)
392 (15.45)
406 (15.97)
407 (16.02)
431 (16.98)
445 (17.50)
446 (17.55)
456 (17.95)
469 (18.47)
470 (18.52)

99 (3.88)
116 (4.58)
116 (4.58)
99 (3.88)
116 (4.57)
116 (4.57)
98 (3.85)
115 (4.54)
115 (4.54)
98 (3.85)
115 (4.54)
115 (4.54)
96 (3.76)
113 (4.45)
113 (4.45)

* SAE rated flows (@1200 rpm and 100 psi) of V10, V10F & V10P cover-end pump (see page 67).
For detailed dimensions of double pump end, see pages 26 through 28; for V10 series cover-end
pump, see pages 69 and 70.

www.Go2Hydraulics.com

45

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Shaft Triple Pumps


Dimensions No. 297 shaft
Dimensions in millimeters (inches)

2520VQSV10
352*VQSV10
45**VQSV10

41,1 (1.62)
55,4 (2.18)
55,4 (2.18)

7,9 (.31)
7,9 (.31)
7,9 (.31)

27,7 (1.09)
35,1 (1.38)
40,4 (1.59)

Model

C DIA.

SEE SPLINE DATA


CHART BELOW.
B

Spline data No. 297 shaft


Dimensions in millimeters (inches)
Model
2520VQSV10

No. of
teeth
13

Pitch
16/32

352*VQSV10

14

12/24

45**VQSV10

14

12/24

Major
dia.
21,8 (.858)
21,6 (.852)
31,2 (1.229)
31,1 (1.223)
31,2 (1.229)
31,1 (1.223)

Form
dia.
19,0
(.749)
27,4
(1.08)
27,4
(1.08)

Minor
dia.
Fit
18,16
(.715)
26,4
Side fit
(1.040)
26,4
(1.040)

Shaft torque ratings No. 297 shaft


Drive shaft
Pump
series

Designation

Max. torque
capability
Nm (lb-in)

2520VQSV10

B per SAE J744C. 22-4 per SAE J744 Oct83

344 (3040)

352*VQSV10

C per SAE J744C. 32-4 per SAE J744 Oct83

791 (7000)

45**VQSV10

C per SAE J744C. 32-4 per SAE J744 Oct83

1017 (9000)

www.Go2Hydraulics.com

46

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Single Thru-drive Pump Operating Specifications


Model
Series

Delivery USgpm
@ 1200 r/min
7 bar (100 psi)

25VQT*S

12
14
17
21
25
30
35
38
42
50
60

35VQT*S

45VQT*S

Displ.
cm3/r
(in3/r)

Max.
r/min

Max.
bar
(psi)

Typical del.
L/min (USgpm)
@ max.
speed &
pressure

Typical input
kW (hp)
@ max.
speed &
pressure

40,2 (2.45)
45,4 (2.77)
55,2 (3.37)
67,5 (4.12)

2700
2700
2500
2500

210 (3000)
210 (3000)
210 (3000)
210 (3000)

88,5 (23)
103,8 (27)
119,2 (31)
146,2 (38)

41,0 (55)
46,6 (62.5)
51,8 (69.5)
61,9 (83)

81,6 (4.98)
97,7 (5.96)
112,8 (6.88)
121,6 (7.42)
138,7 (8.46)
162,3 (9.90)
193,4 (11.80)

2500
2500
2400
2400
2200
2200
2200

210 (3000)
210 (3000)
210 (3000)
210 (3000)
175 (2500)
175 (2500)
175 (2500)

173,1 (45)
211,5 (55)
230,8 (60)
250,0 (65)
255,8 (66.5)
303,8 (79)
369,2 (96)

75,3 (101)
87,7 (117.5)
98,5 (132)
104,4 (140)
91,4 (122.5)
105,2 (141)
126,8 (170)

Approx.
Wt.
kg
(lb.)

19,5 (43)

28,6 (63)

38,2 (84)

Performance constants:

SAE 10W fluid @ 82 C. (180 F.)


Pump inlet @ 0 PSIG (14.7 PSIA)
Note: Outlet pressure must always be higher than inlet pressure. See page 5 for details.

Typical Performance
For thru-drive performance, use
curves on the following pages:
Thrudrive
model series

Page no.

25VQT*S
35VQT*S
45VQT*S

20
21
22

www.Go2Hydraulics.com

47

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Model Codes

Thru-drive Single Pump

F3 Viton seals
Omit if not required.

Intravane pump series Thru-drive


Standard bearing

26VQT
36VQT

Heavy duty bearing

Code
A
B
BP
C

SAE Designation
J744C
J744 Oct83
A
82-2
B
101-2
Special mounting with spacer
for Vickers PVE12/19/21
C
127-2
(not available on 25VQT)

Front mounting flange

Model
series
2*VQT
3*VQT
45VQT

SAE Designation
J744C
B
C
C

10

Series

Code

cm3/r

(in3/r)

2*VQT

12
14
17
21

40,2
45,4
55,2
67,5

(2.45)
(2.77)
(3.37)
(4.12)

3*VQT

25
30
35
38

81,6
97,7
112,8
121,6

(4.98)
(5.96)
(6.88)
(7.42)

Thru-drive connection
mounting adapter (2-bolt)

11

25VQT
35VQT
45VQT

Geometric displacement
Code = SAE rating USgpm at 1200 r/min

J744 Oct83
101-2
127-2
127-2

45VQT

42
50
60

138,7
162,3
193,4

12

10

Shaft type
203 - Heavy duty straight key
297 - Splined
Outlet positions
(Viewed from cover end of pump)
A Opposite inlet
B 90 CCW from inlet
C In line with inlet
D 90 CW from inlet
12

Adapter mounting orientation

(Viewed from cover end of pump)


Code A adapter
B adapter
A Rotated 45
In line with
CW with
pump mtg. flg.
respect to
pump mtg. flg.

SAE Port connections


4-bolt flange port connection

B
Metric threads on port connections
(Omit for inch threads)
7

Double shaft seal


S
Double shaft seal
Blank Single seal
9 Coupling for tandem pump
2 - SAE splined coupling
included with pump

14

11

(8.46)
(9.90)
(11.80)

13

Rotated 45
Rotated 90
CCW with
with respect
respect to
pump mtg. flg. to pump mtg. flg.

Design
Subject to change. Installation
dimensions remain the same for
designs -20 through -29.
13

14

Shaft rotation
(Viewed from shaft end of pump)
L Left hand (counterclockwise)
R Right hand (clockwise)

NOTE:
For options other than listed above,
i.e. shafts, ports, displacements
and mountings, contact your
Vickers representative.

www.Go2Hydraulics.com

48

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions
25VQT*S Series
Dimensions in millimeters (inches)
Shaft options are shown on page 56.
See page 119 for selection of SAE 4-bolt
flanges for port connection pads.

63,5 (2.50)
inlet port
connection

.50013 UNC2B Thd.


or M12 .94 deep, 4 holes
50,8
(2.00)
25,4 (1.00)

44,5
(1.75)

26,2
(1.03)

88,9
(3.50)

25,4 (1.00)
outlet port
connection
.37516 UNC2B Thd.
.75 deep, or M10 thd.
.79 deep, 4 holes

13,1
(.52)

52,4
(2.06)

9,7
(.38)

26,2
(1.03)

A"
See chart on pages 5254.
111,1
(4.38)

101,6 (4.00)

No. 297 shaft.


Involute spline.
Flat root, side fit.
13 teeth, 16/32 pitch.
30 pressure angle.
.858/.852 major dia.
.715 minor diameter.

12,7
(.50)

174,8
(6.88)
38,1
(1.50)

87,4
(3.44)

41,1
(1.62)

76,2
(3.00)
84,1
(3.31)

27,7 (1.09)
7,9
(.31)

Data for rear mountings shown on pages 5254.

www.Go2Hydraulics.com

14,2 (.56)

120,7
(4.75)

73,2
(2.88)
146,1
(5.75)

49

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

35VQT*S Series
Dimensions in millimeters (inches)
Shaft options are shown on page 56.
See page 119 for selection of SAE 4-bolt
flanges for port connection pads.

.62511 UNC2B thd. 1.12 deep, or


M16 thd. 1.18 deep,
4 holes
76,2 (3.00)
62,0
inlet port
(2.44)
connection
31,0
(1.22)

53,1
(2.09)

29,5
(1.16)

106,4
(4.19)

58,7
(2.31)

127,0 (5.00)

12,7
(.50)
31,8 (1.25) outlet
port connection
.43714 UNC2B thd.
.88 deep, or M12 thd.
.88 deep, 4 holes

15,0
(.59)

15,7
(.62)

30,2
(1.19)

No. 297 shaft.


Involute spline.
Flat root, side fit.
14 teeth, 12/24 pitch.
30 pressure angle.
1.229/1.223 major dia.
1.04 minor diameter.

A"
See chart on pages 5255.
122,2
(4.81)

38,1
(1.50)

212,9
(8.38)

55,4
(2.18)

106.2
(4.18)

83,8
(3.3)

35,1 (1.38)

7,9
(.31)

Data for rear mountings shown on pages 5255

www.Go2Hydraulics.com

88,9
(3.5)

17,5
(.69)

147,6
(5.81)

90,4
(3.56)
181,1
(7.13)

50

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions
45VQT*S Series
Dimensions in millimeters (inches)
Shaft options are shown on page 56.
See page 119 for selection of SAE 4-bolt
flanges for port connection pads.

.625-11 UNC-2B or
M16 thd.
31,8 (1.25) deep
4 holes

69,9
(2.75)
35,1
(1.38)

88,9 (3.50)
inlet port
connection
35,1
(1.38)

60,5
(2.38)

127,0 (5.00)
69,9
(2.75)

120,7
(4.75)
12,7
(.50)

17,8
(.70)

38,1 (1.50)
outlet port
connection

35,8
(1,41)

15,7
(.62)

.500-13 UNC-2B thd.


or M12 thd.
23,9 (.94) deep, 4 holes

A"
See chart on pages 5255

129,8
(5.11)

No. 297 shaft.


Involute spline.
Flat root, side fit.
14 teeth, 12/24 pitch.
30 pressure angle.
1.229/1.223 major dia.
1.04 minor diameter.

42,9
(1.69)

212,9 (8.38)

55,4
(2.18)

106.4
(4.19)
102,4
(4.03)
93,7
(3.69)

17,5
(.69)
thru
2 holes

39,6
(1.56)
7,9
(.31)

Data for rear mountings shown on pages 5255.

90,4
(3.56)
181,1
(7.13)

www.Go2Hydraulics.com

147,6
(5.81)

51

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Thru-drive Rear Mountings

A rear mounting
Dimensions in millimeters (inches)
This unit accepts a hydraulic pump with
a mounting configuration of the 82-2 (A)
size per SAE std. J-744 Oct83. The
output coupling is for a pump shaft of
SAE A size with a 30 involute spline
(per SAE std J-744 Oct83), 9T and
16/32 D.P. (Per ANSI B.92.1a1976).
Concentricity of the shaft of the
attached pump must meet or exceed
requirements of SAE Std. J-744 Oct83.
A"
To mounting flange
face

133.4
(5.25)

6,6
(.26)

66,5
(2.62)
1,5
(.06)

.37518 UNC2B thd.


.850 thru flange, 2 holes
(inch threads)

66,5
(2.62)

53,1
(2.09)

106,4
(4.19)

Pump
model

82,6
(3.25)

50,8
(2.00)

45
Output coupling
130,3
(5.13)

Dimension A

Dimension L *

25VQTAS

236, 2 (9.3)

32,5/31,0 (1.28/1.22)
33,0 (1.30) maximum

35VQTAS

259,1 (10.2)

32,5/31,0 (1.28/1.22)
35,6 (1.40) maximum

45VQTAS

292,1 (11.5)

32,5/31,0 (1.28/1.22)
35,3 (1.39) maximum

L"

Snap ring
AS 568
230
Oring
required

* CAUTION: Dimension L is important and must be observed.

www.Go2Hydraulics.com

52

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Thru-drive Rear Mountings

B rear mounting
Dimensions in millimeters (inches)
This unit accepts a hydraulic pump with
a mounting configuration of the 101-2
(B) size per SAE std. J-744 Oct83. The
output coupling is for a pump shaft of
SAE B size with a 30 involute spline
(per SAE std J-744 Oct83), 13T and
16/32 D.P. (Per ANSI B.92.1a1976).
Concentricity of the shaft of the
attached pump must meet or exceed
requirements of SAE Std. J-744 Oct83.

.50013
UNC2B thd.
.760 thru
flange, 2
holes

Output
coupling

174,8
(6.88)

A"
To mounting flange face
5,8
(.23)

66,5
(2.62)

9,9
(.39)

101,6
(4.00)
56,6
(2.23)

133,4
(5.25)
84,1
(3.31)
Snap ring
72,6
(2.86)

L"

AS 568234
Oring required

146,1
(5.75)

NOTE:
For mounting PVE12/19/21,
use BP adapter.
Pump
model

Dimension A

Dimension L *

25VQTBS

246,4 (9.7)

42,4/39,9 (1.67/1.57)
45,2 (1.78) maximum

35VQTBS

269,2 (10.6)

42,4/39,9 (1.67/1.57)
46,7 (1.84) maximum

45VQTBS

299,7 (11.8)

42,4/39,9 (1.67/1.57)
46,2 (1.82) maximum

* CAUTION: Dimension L is important and must be observed.

www.Go2Hydraulics.com

53

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

BP rear mounting
Dimensions in millimeters (inches)
This SAE B size unit with spacer
accepts a Vickers PVE12/19/21
pump.The output coupling is for a pump
shaft of SAE B size with a 30 involute
spline (per SAE std J-744 Oct83), 13T
and 16/32 D.P. (Per ANSI B.92.1a1976).

174,8
(6.88)

A
To mounting flange face

Snap ring

66,5
(2.62)

Output
coupling

10,2
(.40)

101,6
(4.00)
63,5
(2.50)

133,4
(5.25)

84,1
(3.31)
AS 568155
Oring required

73,2
(2.86)
146,1
(5.75)

Pump
model

Dimension A

.563 DIA. thru flange


BP spacer to .50013
UNC-2B thd. of B
adapter 2 places

AS 568234
O-ring required

Dimension L *

25VQTBPS

261,9 (10.31)

45,7/43,2 (1.80/1.70)
Not SAE std.

35VQTBPS

284,5 (11.20)

45,7/43,2 (1.80/1.70)
Not SAE std.

45VQTBPS

317,0 (12.48)

45,7/43,2 (1.80/1.70)
Not SAE std.

* CAUTION: Dimension L is important and must be observed.

www.Go2Hydraulics.com

54

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Thru-drive Rear Mountings

C rear mounting
Dimensions in millimeters (inches)
This unit accepts a hydraulic pump with
a mounting configuration of the 127-2
(C) size per SAE std. J-744 Oct83. The
output coupling is for a pump shaft of
SAE C size with a 30 involute spline
(per SAE std J-744 Oct83), 14T and
12/24 D.P. (Per ANSI B.92.1a1976).
Concentricity of the shaft of the
attached pump must meet or exceed
requirements of SAE Std. J-744 Oct83.

212,9 (8.38)
181,1
(7.13)

A
To mounting flange face

90,4
(3.56)

13,2
(.52)

.625-11
UNC- 2B thd.
1.45 thru
flange, 2
holes

127,0
(5.00)

60,5
(2.38)

84,1
(3.31)
Snap
ring
AS 568-160
O-ring required
147,6
(5.81)

Pump
model

Dimension A

Dimension L *

35VQTCS

276,9 (10.9)

56,6/54,1 (2.23/2.13)
61,2 (2.41) maximum

45VQTCS

307,3 (12.1)

56,6/54,1 (2.23/2.13)
61,5 (2.42) maximum

Output
coupling

* CAUTION: Dimension L is important and must be observed.

www.Go2Hydraulics.com

55

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Optional Shafts
#203 Straight keyed heavy duty shaft
Dimensions in millimeters (inches)
Note: No. 297 spline shaft
shown on pages 49-51.

A
Key (see chart)

7,9
(.31)

Dimensions
B

25VQT*S 77,7 (3.06)

9,53 (.375)

35VQT*S 84,1 (3.31)

12,7 (.500)

45VQT*S 90,4 (3.56)

12,7 (.500)

25,40 (1.000)
25,35 (.998)
34,90 (1.374)
34,87 (1.373)
38,07 (1.499)
38,05 (1.498)

28,19 (1.110
27,94 (1.100)
38,56 (1.518)
38,30 (1.508)
42,37 (1.668)
42,11 (1.658)

Model

www.Go2Hydraulics.com

Key
6,35 (.250) sq. x 50,8 (2.00)
7,94 (.313) sq. x 54,0 (2.13)
9,53 (.375) sq. x 57.2 (2.25)

56

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Maximum Torque Loading for Direct Drives


Single pumps
All listed shafts are satisfactory up to
maximum pressures in Pressure and
speed limits in operating data for each
series.

Table 2
Single Thru-drive Pumps
and Triple Pumps
Shaft Torque Ratings

Double pumps
Where both cartridges are to be on-load
together, check that the sum of their
separate torques, taken from the graph
below (right), does not exceed the
torque limit in shaft torque Table 1.

Pump
Model

Shaft
No.

Max. Input
Torque
Nm (lb. in.)*

25VQT

203

402 (3560)

A
B

131 (1160)
316 (2800)

25VQT or
2520VQSV10

297

344 (3040)

A
B

131 (1160)
316 (2800)

35VQT

203

659 (5830)

A
B
C

131 (1160)
348 (3080)
437 (3870)

35VQT or
352*VQSV10

297

791 (7000)

A
B
C

131 (1160)
348 (3080)
437 (3870)

45VQT

203

982 (8690)

A
B
C

131 (1160)
384 (3400)
702 (6210)

45VQT or
45*5VQSV10

297

1017 (9000)

A
B
C

131 (1160)
384 (3400)
702 (6210)

Pump
Model

Shaft
Number

Maximum
Input Torque
Nm (lb. in.)

25VQ or
25**VQ

1
86
11
123
203
297

316 (2800)
402 (3560)
316 (2800)
316 (2800)
402 (3560)
344 (3040)

1
11
86
123
203
297

402 (3560)
791 (7000)
659 (5830)
791 (7000)
659 (5830)
791 (7000)

1
11
86
130
203
297

402 (3560)
1017 (9000)
982 (8690)
1017 (9000)
982 (8690)
1017 (9000)

35VQ or
35**VQ

45VQ or
45**VQ

Example:
A 3525VQ38A17 pump operating at 175 bar
(2500 psi) front section and 140 bar (2000 psi)
rear section will require over 452 Nm (4000
lb. in.) input torque. Therefore, all listed shafts
are acceptable except No. 1.

www.Go2Hydraulics.com

* Combined torque of Vickers VQT pump and thru-driven pump

Input Torque Requirement


678
(6000)
565
(5000)

60
50

452
(4000)

42

339
(3000)

38
35
30
25

226
(2000)

21
17
14
12
11
8
5

113
(1000)

35
(500)

70
(1000)

100
(1500)

140
(2000)

175
(2500)

Displacement Code

Table 1
Single & Double Pumps
Shaft Torque Ratings

Input torque - Nm (lb.in.)

Single thru-drive pumps


and triple pumps
Where both the thru-drive pump and its
rear-mounted pump are to be on-load
together, check that the sum of the
torques generated will never exceed the
torque limit in shaft torque Table 2. Also
check that the torque required on the
rear-mounted pump never exceeds the
thru-drive torque limit in shaft torque
Table 2.

Max.
Thru-drive
Torque Nm (lb. in.)

Thru-drive
Connection

210
(3000)

Operating Pressure - bar (psi)

57

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Double Thru-drive Pump Operating Specifications

Model
Series

3525VQT

Displacement Code
(USgpm at 1200 r/min
and 7 bar (100 psi))

Displacement
cm3/rev (in3/rev)

Rated
Speed
r/min

Maximum
Pressure
bar (psi)

Typical Delivery
at Max Speed
and Pressure
l/min (USgpm)

Typical Input Power


at Maximum Speed
and Pressure
kW (hp)

25

81,6 (4.98)

2500

207 (3000)

173,1 (45)

75 (101)

30

97,7 (5.96)

2500

207 (3000)

211,5 (55)

88 (117.5)

35

112,8 (6.88)

2400

207 (3000)

230,8 (60)

98 (132)

38

121,6 (7.42)

2400

207 (3000)

250,0 (65)

104 (140)

12

40,2 (2.45)

2500

207 (3000)

79,0 (21)

38 (51)

14

45,4 (2.77)

2500

207 (3000)

91,0 (24)

43 (58)

17

55,2 (3.37)

2500

207 (3000)

119,2 (31)

51,8 (69,5)

21

Front Pump

Rear Pump

67,5 (4.12)

2500

207 (3000)

146,2 (38)

62 (83)

42

138,7 (8.46)

2200

172 (2500)

255,8 (66.5)

91 (122.5)

50

162,3 (9.90)

2200

172 (2500

303,8 (79)

105 (141)

60

193,4 (11.80)

2200

172 (2500)

369,2 (96)

127 (170)

12

40,2 (2.45)

2200

207 (3000)

68,0 (18)

33 (44)

14

45,4 (2.77)

2200

207 (3000)

79,0 (21)

38 (51)

17

55,2 (3,37)

2200

207 (3000)

100,0 (26.5)

45 (61)

21

67,5 (4.12)

2200

207 (3000)

125,0 (33)

54 (73)

4525VQT

Performance constants: SAE 10W oil @ 82C (180F) and pump inlet @ 0 psig (14.7 psia).
Note: Outlet pressure must always be higher than inlet pressure. See page 6 for details.

Typical Performance
For thru-drive performance, use curves on
the following pages:
Page Number
Model
Series

Shaft-end
Pump

Rear Pump

3525VQT

33

37

4525VQT

34

39

www.Go2Hydraulics.com

58

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Model Codes

Thru-drive Double Pump

(F3) **25 VQT * S ** A * ** (S) 2 297 ** (*) 20


1

1
F3 Viton seals
Omit if not required

Port connections
A SAE 4-bolt flange
AM Metric 4-bolt flange (Flange pads
stamped M for metric threads)
Geometric displacement,
cover end pump
Code = SAE rating (USgpm) at
1200 rpm and 6,9 bar (100 psi)
Pump
Code
cm3/r
series
40
**25VQT 12
45
14
55
17
68
21
7

Thru-drive (rear) 2-bolt


mounting flange
A SAE A flange
B SAE B adapter flange
BP SAE B spacer flange
for Vickers PVE12, 19,
or 21 pump
3

in3/r
2.45
2.77
3.37
4.12

Shaft seal assembly


S Single seal
Omit for double seal

S SAE J-744 (127-2)


5

Thru-drive coupling
2 With spline for tandem pump
9

in3/r
4.98
5.96
6.88
7.42
8.46
9.90
11.80

10

11

12

13

14

With no. 1 outlet in line with inlet


CA No. 2 outlet 135 CCW from inlet
CB No. 2 outlet 45 CCW from inlet
CC No. 2 outlet 45 CW from inlet
CD No. 2 outlet 135 CW from inlet
With no. 1 outlet 90 CW from inlet

Front mounting flange

Geometric displacement,
shaft end pump
Code = SAE rating (USgpm) at
1200 rpm and 6,9 bar (100 psi)
Pump
Code
cm3r
series
25
81,6
3*25VQT
30
97,7
35
112,8
38
121,6
42
138,7
4525VQT
50
162,3
60
193,4

2 Series designation
3525VQT (standard bearing)
3625VQT (3525VQT with heavy
duty bearing)
4525VQT (standard bearing)

Shaft
297 Splined
C size per SAE J744C
32-4 per SAE J744 Oct 83
10

DA No. 2 outlet 135 CCW from inlet


DB No. 2 outlet 45 CCW from inlet
DC No. 2 outlet 45 CW from inlet
DD No. 2 outlet 135 CW from inlet
Thru-drive (rear) mounting
flange position
(Viewed from cover end of pump)
A In line with no. 2 outlet port in
all cases
B 90 from no. 2 outlet port in
all cases
Omit for **25VQTA models
12

13 Design
Subject to change. Installation
dimensions remain unchanged for
designs 20 through 29.
14 Rotation
(Viewed from shaft end of pump)
L Left hand (counterclockwise)
R Right hand (clockwise)

11 Port position
(Viewed from cover end of pump)
With no. 1 outlet opposite inlet
AA - No. 2 outlet 135 CCW from inlet
AB - No. 2 outlet 45 CCW from inlet
AC - No. 2 outlet 45 CW from inlet
AD - No. 2 outlet 135 CW from inlet

With no. 1 outlet 90 CCW from inlet


BA No. 2 outlet 135 CCW from inlet
BB No. 2 outlet 45 CCW from inlet
BC No. 2 outlet 45 CW from inlet
BD No. 2 outlet 135 CW from inlet

NOTES:
State complete model number when ordering. Example: 3525VQTAS-25A12-2297CC-20R.
Port flange kits with inch screws are available from Vickers and must be ordered separately.
For port flange kits, or mounting, displacement, port, and shaft options other than coded above,
contact your Vickers representative.

www.Go2Hydraulics.com

59

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions

3525VQT Series
Dimensions in millimeters (inches)
Port connection pads are for use with SAE or
metric 4-bolt flanges. Pads stamped with M for
metric threads. See page 119 for selection of SAE
flanges.

M12 thd. 20,6


(.812) deep min.
4 holes (metric thds.)

.43714 UNC2B thd.


20,6 (.812) deep.
4 holes (in. thds.)

76,2 (3.00) Inlet


port conn.

31,75 (1.250). Outlet no. 1 port conn.

127,00
126.95
(5000
4.998)

12,45 (0.490)
.62511 UNC2B thd.
28,5 (1.125) deep.
4 holes (in. thds.)

15,7 (0.62
M12 thread
20,6 (.812) deep min.
4 holes (metric thds.)

25,4 (1.00) Outlet No. 2 port conn.

M10 thread 19,05 (.75) deep


4 holes (metric thds.)
.37516 UNC2B thd. 19,0 (.75) deep
4 holes (in. thd.)
135,1 (5.32)

External Involute Spline


ANSI B92.1a1976
1.1667 pitch dia.
1.0104 base dia.
Flat Root
Side Fit
14 teeth 12/24 pitch 30pr angle
Major Dia.
Form Dia. Minor Dia.
Max
1.229 Max
1.082
1.040 Min
1.223 Min
212,5
(8.36)

343,8 (13.53)

67,6
(2.66)

109.5
(4.31)

122,2
(4.81)

38,1
(1.50)

55,5
(2.19)

106,2
(4.18)

82,6
(3.25)

45

17,48
(0.688)
thru2
holes
7,125
(17,48)

74,7
(2.94)
7,87
(0.310)
See rear mounting dimensions
starting on page 62.

www.Go2Hydraulics.com

88,9
(3.50)

147,6
(5.81)

35,05/34,80
(1.380/1.370)

60

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions

4525VQT Series
Dimensions in millimeters (inches)
Port connection pads are for use with SAE or
metric 4-bolt flanges. Pads stamped with M for
metric threads. See page 119 for selection of SAE
flanges.

M12 thread
23,83 (.94) deep. 4
holes (metric thds.)

.500-13 UNC-2B
thd. 23,831 (.938)
deep 4 inch thds

88,90 (3.500)
Inlet port conn.

38,10 (1.500)
Outlet No. 1 port conn.

126,95
127,00
(5.000
4.998)

M16 thread
31,75 (1.25) deep min.
4 holes (metric thds.)

12,45
(0.490)
15,8 (0.62)
.625-11 UNC-2B thd.
31,75 (1.250) deep 4
holes (inch thds.)
25,4 (1.00)
Outlet No. 2
port conn.
External Involute Spline
ANSI B92.1a1976
1.0104 base dia.
1.1667 pitch dia.
Flat Root
Side Fit
14 teeth 12/24 pitch 30pr angle
Major Dia.
Form Dia.
Minor Dia.
Max
1.229 Max
1.082
1.040 Min
1.223 Min

M10 thread
19,05 (.75) deep.
4 holes (metric thds.)
.375-16 UNC-2B thd.
18,0 (.75) deep. 4
holes (inch thds.)
382,4
(15.06)

180,3
(6.31)

135,8
(5.35)

80,1
(3.18)

129,9
(5.11)

42,9 55,8
(1.69) (2.19)

212,5
(8.38)
106,2 (4.18)

93,66
(3.688)

102,39
(4.031)
79,4
(3.12)

79,4
45
(3.12)

17,48
(0.688)
thru. 2
holes
180,98
(7.125)

84,1
74,7 (3.31)
(2.84)
81,0
(3.19)
158,8 (6.25)
162.1 (6.38)

www.Go2Hydraulics.com

7,87
(0.310)
See rear mounting dimensions
starting on page 62.

147,6
(5.81)

40,51/40,26
(1.595/1.585)

61

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Rear Mountings for Thru-drive Double Pumps

A Rear Mounting
(SAE 822 size).
Dimensions in millimeters (inches)
MS28775042
Alternate O ring

32,5/31,0
(1.28/1.22)
Important
dimension.
Must be
observed.

1,45/1,30
(0.057/0.051)

ARP568230
O Ring

Output coupling for


pump shaft. SAE A
size with 30 involute
spline (per SAE std.
J744 Oct 83). 9T,
16/32 D.P. (per ANSI
B92.1a1976)

82,63/82,58
(3.253/3.251)
47,50
(1.870)
87,53/87,27
(3.446/3.436)
45
6,53/6,38
(0.257/0.251)
106,38
(4.188)

Snap ring

9,19/9,04
(0.362/0.356)

.37516 UNC2B thd 4 plcs.

16,26/15,49
(0.640/0610)
343,8 (13.53) to 3525VQT
mounting flange face.
382,4 (15.06) to 4525VQT
mounting flange face.

B Rear Mounting
(SAE 1012 size).
Dimensions in millimeters (inches)
This unit accepts hydraulic pump
with SAE mounting configuration of
1012(B) size per SAE std. J744
Oct 83.

NOTE: Concentricity of shaft of


attached product must be to SAE
std. J744 Oct.83 or better.

374,3 (14.74)
To mtg. flange face
19,05
(0.750)

.50013 UNC2B thd


thru adapter flange,
2 holes (inch thds.)
101,68
101,63
(4.003
4.001)
73,02
(2.875)

45

174,8
(6.88)

www.Go2Hydraulics.com

148,05
(5.750)

Output coupling for pump


shaft. SAE B size with
30 involute spline (per
SAE std. J744 Oct 83).
13T, 16/32 D.P. (per
ANSI B92.1a1976)

56,6
(2.23)

0,8 (0.03) x 45

9,98/9,78
(0.393/0.385)
2,23 (5.8)

Snap ring
Adaptor flange
42,4/39,9
(1.67/1.57)

62

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Rear Mountings for Thru-drive Double Pumps

BP Rear Mounting
(SAE B size with spacer for
Vickers PVE19/21 pumps)
Dimensions in millimeters (inches)

133,1
(5.24)

390,6 (15.38)
To mtg. flange face

14,3 (0.563) thru spacer,


2 holes. .50013 UNC2B thread
thru adapter flange,
2 holes
(inch threads)

10,16/9,91
(0.400/0.390)
3,68/3,56
(0.145/0.140)

Spacer
AS568155 Oring

Z
Z
Section ZZ
(typ. 2 plcs.)

101,68
63,5
56,6
101,63 (2.50)
(2.23)
(4.003
4.001)

73,02
(2.875)

45

Snap ring
16,3 (0.64)

174,8
(6.88)

www.Go2Hydraulics.com

148,05
(5.750)

Output coupling for a


Vickers pump shaft.
SAE B size with 30
involute spline (per
SAE std. J744
Oct 83). 13T, 16/32
D.P. (per ANSI
B92.1a1976)

Adaptor flange

45,7/43,2 (1.80/1.70)
Not SAE standard

63

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Maximum Torque Loading for Direct Drives

Double Thru-drive Pumps


As pictured at right, a coupled double
VQT pump and thru-driven pump are
essentially three pumps driven by one
drive shaft. It is critical that the the sum
of the torque required for each pumping
section not exceed the maximum torque
capability of the drive shaft.

No.1 pumping
section (outlet)

Inlet for pumping sections 1 and 2


No. 2 pumping
section (outlet)

Drive
shaft

Inlet for pumping


section no. 3

Use the following procedure to ensure


proper loading on the drive shaft:

No. 3 pumping section (outlet)


Figure 1

2. Determine maximum operating


torque of pumping section #2 from
Rear Pump Torque Requirements
figure #3 on following page.

3*25VQTs Front Pump


Input Torque Requirements

Torque (lb.in.)

5000

3. Determine maximum operating


torque of thru-driven pump (pumping
section #3) from its specific catalog
data, or estimate the torque using
the following formula:

4000
3000
2000
1000

Torque = (1.15  displacement 


pressure)  6.28

Torque (Nm)

1. Determine maximum operating


torque of pumping section #1 from
Front Pump Torque Requirements
figure #1 or #2 at right.

550
500
450
38 USgpm
35 USgpm
400
30 USgpm
350
300
25 USgpm
250
21 USgpm
200
150
100
50
00 25 50 75 100 125 150 175 200 225
Pressure (bar)

Note: Actual torque may be higher or


lower than estimated.

4525VQTs Front Pump


Input Torque Requirements

6000
5000
4000
3000
2000
1000
0

Torque (Nm)

5. Sum all torque values from steps 1,


2 and 3 above. This value must not
exceed the Maximum Input Torque
value in figure #4 on following page.

500 1000 1500 2000 2500 3000 3500


Pressure (psig)

Figure 2

Torque (lb.in.)

4. Ensure the torque determined for


the #3 pumping section does not
exceed the Maximum Thru-drive
Torque for the double VQT pump in
figure #4 on following page.

650
600
60 USgpm
550
57 USgpm
500
50 USgpm
450
47 USgpm
42 USgpm
400
350
300
250
200
150
100
50
0
0 25 50 75 100 125 150 175 200
Pressure (bar)
0

www.Go2Hydraulics.com

500 1000 1500 2000 2500 3000


Pressure (psig)

64

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Maximum Torque Loading for Direct Drives

Figure 3

Figure 4
**25VQTs Rear Pump
Input Torque Requirement

Torque (lb.in.)

2000
1500
1000
500
0

Torque (Nm)

2500

275
250
225
200
175
150
125
100
75
50
25
0

Model
Max. Torque Nm (lb in)
Series
Input
Thru-drive
3*25VQTA 790 (7000)
131 (1160)
3*25VQTB 790 (7000)
316 (2800)
3*25VQTBP 790 (7000)
316 (2800)
4525VQTA 1017 (9000) 131 (1160)
4525VQTB 1017 (9000) 316 (2800)
4525VQTBP 1017 (9000) 316 (2800)

21 USgpm
19 USgpm
17 USgpm
14 USgpm
12 USgpm

Combined torque of Vickers thru-drive


double pump and thru-driven pump.

0 25 50 75 100 125 150 175 200 225


Pressure (bar)
0

500 1000 1500 2000 2500 3000 3500


Pressure (psig)

Typical Rear-mounted Pumps for **25VQT Thru-drive Assemblies


Mounting
Piston Pump
Shaft
Vane Pump
Model Series
Code
Model Series
SAE A
PVQ10/13
3
V10
V20
SAE B
PVQ20/32
3
20V
PVQ40/45
3
25V
PVE12
2
V2020
PVE19/21
9

Shaft
Code
11
62
151
11
11

NOTE: Torque limits in Figure 4 must not be exceeded when applying the above
Vickers pumps.

www.Go2Hydraulics.com

65

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

V10, V20, V2010 & V2020 Single & Double Pumps

Single Pumps

Double Pumps

Versatile

Priority Valve

High flow, pressure and speed


capabilities enable these pumps to meet
the needs of modern vehicle hydraulic
circuits. Optional flow control and priority
valve covers offer even more versatility.

The priority valve cover maintains nearly


a constant flow to a primary circuit and
diverts the remaining flow to a
secondary circuit. Flow going to the
secondary circuit is determined by pump
delivery. The primary circuit is protected
by an integral relief valve but an external
relief valve must be provided for the
secondary circuit.

Flow Control
The flow control cover limits flow to the
operating system to the desired
maximum. Excess flow is diverted to
tank. On double pumps, shaft-end pump
delivery is proportional to speed.
The flow control cover also includes a
relief valve to limit maximum system
pressure.
A typical application of a flow control is
in a power steering unit where it
provides a constant supply of oil over
the engines mid to high speed range.

www.Go2Hydraulics.com

Reliable
The superior design of these units
makes them last longer ... theyve
proven theyll hold up in rugged
applications such as trenchers,
backhoes and tractors.

As a result, pressure-induced radial


loads are balanced ... bearings have to
carry the external load only.

Performance
Low vane tip/ring loading allows high
pressure operation. High speeds are
possible because the inlet flow paths are
designed to give uniform oil acceleration
- thus better filling - particularly at low
inlet pressures.

Low Cost
Vickers efficient design produces extra
horsepower per dollar of pump
investment - providing industry with low
pump cost per horsepower capacity.

Hydraulic Balance
Internal inlet and outlet pressure
chambers are diametrically opposed.

66

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Single Pump Operating Specifications


Model
Series

Delivery USgpm
@ 1200 rpm
7 bar (100 psi)

Displ.
cm3/r
(in3/r)

Max.
r/min

Max.
bar
(psi)

Typical del..
L/min (USgpm)
@ max.
speed &
pressure

Typical input
kW (hp)
@ max.
speed &
pressure

V10
V10F
V10P

1
2
3
4
5
6
7

3,3 (.20)
6,6 (.40)
9,8 (.60)
13,1 (.80)
16,4 (1.00)
19,5 (1.19)
22,8 (1.39)

4800
4500
4000
3400
3200
3000
2800

172 (2500)
172 (2500)
172 (2500)
172 (2500)
172 (2500)
152 (2200)
138 (2000)

13,6 (3.6)
27,7 (7.3)
35,6 (9.4)
41,3 (10.9)
48,5 (12.8)
55,3 (14.6)
60,6 (16)

5,2 (7)
10,1 (13.6)
13,3 (17.8)
15,2 (20.4)
17 (22.8)
18,3 (24.5)
17,9 (24)

V20
V20F
V20P

6
7
8
9
11
12
13

19,5 (1.19)
22,8 (1.39)
26,6 (1.62)
29,7 (1.81)
36,4 (2.22)
39 (2.38)
42,5 (2.59)

3400
3000
2800
2800
2500
2400
2400

172 (2500)
172 (2500)
172 (2500)
172 (2500)
172 (2500)
152 (2200)
152 (2200)

61,0 (16.1)
63,3 (16.7)
67,1 (17.7)
75,0 (19.8)
86,8 (22.9)
87,2 (23)
98,1 (25.9)

21,6 (29)
22 (29.5)
24,2 (32.5)
26,5 (35.5)
28 (37.5)
26,8 (36)
29,1 (39)

Wt.
kg
(lb.)

4,5 - 6,8
(10 - 15)

7,3 - 8,2
(16 - 18)

Note: Review Applying Vane Units page 5 prior to selection of pump.

www.Go2Hydraulics.com

67

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Model Codes

V 20 F - 1 P 13 S - 1 A 8H 22 L
1

Vane pump

Series

10

11

12

Tank

9/16-18
St. thd.
(V10P)

3/4-16
St. thd.
(V10P)

Mounting
1 2-bolt flange
6 2 bolt flange (SAE B size)
Inlet port connections

D - 1 5/16-12 str. thd. (V20 only)


P - 1 NPT thread (V10 only)
1 1/4 NPT thread (V20 only)
S - 1 5/16-12 str. thd. (V10 only)
1 5/8-12 str. thd. (V20 only)
T - 1 3/16-12 str. thd. (V10 only)
6

SAE rated capacity USgpm


(1200 r/min & 100 psi)

V10
series

1/2 NPT thd.

(V10 only)
3/4 NPT thd. 3/4-16
(V20 only)
St. thd.
(V10F &
V20F)
3/416

St. thd.
(V10 only)
1-1/1612
St. thd.
(V20 only)

1/2 NPT thd.


(V10F & V20F)

3/4-16
St. thd.
(V20F)

1-1/1612
St. thd.
(V20F)

3/4-16
St. thd.
(V10F)

3/4-16
St. thd.
(V10F)

7/8-14
St. thd.
(V20P)

9/16-18
St. thd.
(V10P)

3/4-16
St. thd.
(V20P)

Design

Subject to change. Installation


dimensions remain the same for
designs 20 through 29.
12

Shaft rotation
(Viewed from shaft end of pump)
L Left hand for counterclockwise.
Omit for right hand.

Position of outlet or primary


outlet port
(Viewed from cover end of pump)
A Opposite inlet port
B 90 CCW from inlet
C In line with inlet
D 90 CW from inlet
10

3/4-16
St. thd.
(V20P)

11

8
Shafts
1 Straight keyed
3 Threaded with woodruff key
11 Splined
12 Splined (V10 only)
38 Splined
62 SAE A Spline (V20 only)
9

V20
series

Priority valve cover


Primary Secondary
Tank
outlet
outlet

Pressure

Integral valves

Orifice No.
Flow rate
2 8 L/min (2 USgpm)
3 11 L/min (3 USgpm)
4 15 L/min (4 USgpm)
5 19 L/min (5 USgpm)
6 23 L/min (6 USgpm)
7 27 L/min (7 USgpm)
8 30 L/min (8 USgpm)

www.Go2Hydraulics.com

Flow control cover

Integral valve options

4 L/min (1 USgpm)
8 L/min (2 USgpm)
11 L/min (3 USgpm)
15 L/min (4 USgpm)
23 L/min (6 USgpm)
27 L/min (7 USgpm)
23 L/min (6 USgpm)
27 L/min (7 USgpm)
30 L/min (8 USgpm)
34 L/min (9 USgpm)
42 L/min (11 USgpm)
45 L/min (12 USgpm)
49 L/min (13 USgpm)

Std.
cover

1
2
3
4
6
7
6
7
8
9
11
12
13

Code

(Omit if not required)


F Flow control & relief
P Priority valve & relief

Outlet port connections

10 or 20
3

Relief valve setting


A
B
C
D
E
F
G

17 bar (250 psi)


35 bar (500 psi)
52 bar (750 psi)
70 bar (1000 psi)
86 bar (1250 psi)
100 bar (1500 psi)
121 bar (1750 psi)

H 140 bar (2000 psi)


J 155 bar (2250 psi)
K 175 bar (2500 psi)

68

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions

V10 Series
Dimensions in millimeters (inches).
Shaft options shown on page 72.
Delivery @
1200 rpm
& 100 psi

1 USgpm
2 USgpm
3 USgpm
4 USgpm
5 USgpm
6 USgpm
7 USgpm

115,6 (4.55)
115,6 (4.55)
115,6 (4.55)
121,9 (4.80)
121,9 (4.80)
127,0 (5.00)
127,0 (5.00)

91,9 (3.62)
91,9 (3.62)
91,9 (3.62)
98,3 (3.87)
98,3 (3.87)
103,4 (4.07)
103,4 (4.07)

12,7 (.50)

Dimensions

82,55/82,50
21,4 (3.250/3.248)
(.843)
.750-16 UNF-2B THD.
(SHOWN)
OR
.500 NPT THD. OUTLET PORT

1.3125-12 UNF-2B THD. (SHOWN)


OR
1.000 NPT THD. OUTLET PORT CLOCKWISE
ROTATION

A
B
24,6 (.97)

76,2 (3.00)
C

38,1 (1.50)

7,9 (.31)
6,35/6,10
(.250/.240)
44,4
(1.75)
 4,75 (.187) SQ. KEY
25,4 (1.00) LONG

62,7 (2.47)

19,05/19,02
(.750/.749)

46
(1.81)

SAEA
FLANGE
(REF.)
11,9
(.47) R.
10

21,13/21,00
(.832/.827)

10

38,1 (1.50)
NO. 1 SHAFT
53,2
(2.09)

106,3
(4.19)

11,1
(.44)
2 HOLES

95,2
(3.75)

V10F Series
Dimensions in millimeters (inches).
Shaft options shown on page 72.
Delivery @
1200 rpm
& 100 psi

1 USgpm
2 USgpm
3 USgpm
4 USgpm
5 USgpm
6 USgpm
7 USgpm

128,8 (5.07)
128,8 (5.07)
128,8 (5.07)
135,1 (5.32)
135,1 (5.32)
140,2 (5.52)
140,2 (5.52)

109,5 (4.31)
109,5 (4.31)
109,5 (4.31)
115,8 (4.56)
115,8 (4.56)
120,9 (4.76)
120,9 (4.76)

Dimensions
46,0
(1.81)

TANK PORT
.75016 UN2B THD.
OR .500 NPT THREAD

MAJOR DIA.

18,62/18,47
(.733/.727)

INLET PORT
1.000 NPT THD. OR
1.3212512 UN2B THD.
OR 1.187512 UN2B THD.
B
24,6 (.97)

97,5
(3.84)
B

82,55/82,50
(3.250/3.248)

15,2
(.60)

A
106,9
(4.21)
C
60,7
(2.39)

NO. 38 SPLINED SHAFT


INVOLUTE SPLINE
FLAT ROOT
16/32 DIAMETRAL PITCH
11 TEETH 30 PRESS. ANGLE
.590 MINOR DIAMETER

60,5
(2.38)

12,7 (.50)
31,8
(1.25)
6,35/6,10
(.250/.240)

95,3
(3.75)

21,3
106,4 (.84)
20,6 (4.19)
(.81)

11,9
(.47) R.
10

www.Go2Hydraulics.com

OUTLET PORT
.750-16 UN-2B THD.

10

SAE A
FLANGE
(REF.)

11,2 (.44)
2 HOLES

69

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

V10P Series

SECONDARY OUTLET PORT


.750-16 UNF-2B THD.
SAE O-RING BOSS CONNECTION

Dimensions in millimeters (inches).


Shaft options shown on page 72.
Delivery @
1200 rpm
& 100 psi
1 USgpm
2 USgpm
3 USgpm
4 USgpm
5 USgpm
6 USgpm
7 USgpm

Dimensions
A

MAJOR DIA.

130,0 (5.12)
130,0 (5.12)
130,0 (5.12)
136,4 (5.37)
136,4 (5.37)
141,5 (5.57)
141,5 (5.57)

109,5 (4.31)
109,5 (4.31)
109,5 (4.31)
115,8 (4.56)
115,8 (4.56)
120,9 (4.76)
120,9 (4.76)

18,62/18,47
(.733/.727)

24,6
(.97)

6,35/6,10
(.250/.240)

60,5
(2.38)

108,0
(4.25)

.437 D.
THRU
2 HOLES

31,8
(1.25)

102,9
(4.05)

CLOCKWISE
ROTATION

25,4 (1.00) NPT


INLET PORT

12,7 (.50)

COVER POSITION C
50,3
(1.98)

82,55/82,50
(3.250/3.248)

15,2
(.60)

130,0 (5.12) REF.


21,3
(.84)
106,4
(4.19)

20,6
(.81)
10

D
10
55,6
(2.19)
11,9 (.47) R.
A
30,2 (1.19)
16,0 (.63)

95,3
(3.75)

NO. 38 SPLINED SHAFT


INVOLUTE SPLINE
FLAT ROOT
16/32 DIAMETRAL PITCH
11 TEETH 30 PRESS. ANGLE
.590 MINOR DIAMETER

TANK PORT FOR PRESSURE RELIEF


OF PRIMARY OUTLET PORT
.5625-18 UNF-2B THD.
SAE O-RING BOSS CONNECTION
PRIMARY OUTLET PORT
.5625-18 UNF-2B THD.
SAE O-RING CONNECTION

V20 Series

OUTLET PORT
1.062-12 UN-2B STR. THD.
SAE O-RING
BOSS CONNECTION

Dimensions in millimeters (inches).


Shaft options shown on page 72.
Delivery @
1200 rpm
& 100 psi
6 USgpm
7 USgpm
8 USgpm
9 USgpm
11 USgpm
12 USgpm
13 USgpm

NO. 1 SHAFT

Dimensions
A

125,2 (4.93)
131,6 (5.18)
131,6 (5.18)
131,6 (5.18)
136,6 (5.38)
140,2 (5.52)
140,2 (5.52)

102,1 (4.02)
108,4 (4.27)
108,4 (4.27)
108,4 (4.27)
113,5 (4.47)
117,1 (4.61)
117,1 (4.61)

12,7 (.50)

A
55,6
(2.19)

B
31 (1.22)

55,6
(2.19)

31,8 (1.25) NPT


INLET PORT
CLOCKWISE
ROTATION
67,6
(2.66)
4,1
(.16)

66,0
(2.60)

21,13/21,00
(.832/.827)

62,0
(2.44)
B

www.Go2Hydraulics.com

10

82,55/82,50
(3.250/3.248)

D
55,6
(2.19)

.4,76 (1875) X 41,1 (1.62)


LONG KEY

106.4 (4.19)
.004
53,1
(2.09)

19,05/19,02
(.750/.749)

11,1 (.437)
2 HOLES

10
11,9
(.47) R.

47,8 (1.88) R.

70

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions

V20F & V20P Series


Dimensions in millimeters (inches).
Shaft options shown on page 72.
Delivery @
1200 rpm
& 100 psi
6 USgpm
7 USgpm
8 USgpm
9 USgpm
11 USgpm
12 USgpm
13 USgpm

Dimensions
A
149,6 (5.89)
156,0 (6.14)
156,0 (6.14)
156,0 (6.14)
161,0 (6.34)
164,3 (6.47)
164,3 (6.47)

B
125,7 (4.95)
132,1 (5.20)
132,1 (5.20)
132,1 (5.20)
136,9 (5.39)
140,5 (5.53)
140,5 (5.53)

31,8 (1.25) NPT


INLET PORT
18,62/18,47
(.733/.727)

19,1 (.75)

V20P
SECONDARY OUTLET PORT
.875-14 UNF 2B STR THD
SAE O-RING BOSS
CONNECTION

V20F
TANK PORT
12,7 (.50) NPT

12,7 (.50)

106,48/106,27
(4.192/4.184)

A
C
55,6
(2.19)

B
55,6
(2.19)

31,8 (1.25)

53,1
(2.09)

31,0
(1.22)
23,9 (.940)
62,0
(2.44)
D

10

124,0
(4.88)

82,55/82,50
(3.250/3.248)

10

62,0
(2.44)

11,9
(.47) R.
4,1 (.16)

15,7
(.62)

15,7
(.62)

V20P
TANK PORT
.750-16 UNF 2B STR THD
SAE O-RING BOSS
CONNECTION

V20P PRIMARY
OUTLET PORT
.750-16 UNF 2B STR THD
SAE O-RING BOSS
CONNECTION

www.Go2Hydraulics.com

11,2
(.44)
2 HOLES

NO. 38 SPLINED SHAFT


INVOLUTE SPLINE
16/32 DIAMETRAL PITCH
FLAT ROOT
11 TEETH 30 PRESS. ANGLE
.590 MINOR DIAMETER

47,8 (1.88)

V20F
OUTLET PORT
.750-16 UNF 2B STR THD
SAE O-RING BOSS
CONNECTION

71

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Optional Shafts
V10 Series
Dimensions in millimeters (inches)
Note: No. 1 keyed shaft and No. 38
splined shaft shown on pages 69
and 70 respectively.
50,0
(1.97)
41,9
(1.65)

31,8 (1.25) (#11 SHAFT)


41,4 (1.63) (#12 SHAFT)

14,7
(.58)

31,8
(1.25)
3,3 (.13)

#11 SHAFT EXTENSION


(SHOWN)
INVOLUTE SPLINE
FLAT ROOT - MAJOR DIA.
FIT 16/32 DIAMETRAL
PITCH 9 TEETH - .5625 P.D.
30 PRESSURE ANGLE
MAJOR DIA. - .623/.622
MINOR DIA. - .465 MIN.

30,2 (1.19)
15,88/15,85
(.625/.624)
17,73/17,48
(.698/.688)
.500-20 UNF2A THD.

#12 SHAFT EXTENSION


INVOLUTE SPLINE
FLAT ROOT - MAJOR DIA.
FIT 16/32 DIAMETRAL
PITCH 13 TEETH - .8125 P.D.
30 PRESSURE ANGLE
MAJOR DIA. - .873/.872
MINOR DIA. - .715 MIN

3,2 (.125) D.-THRU


#6 WOODRUFF KEY

No. 3 shaft extension

No. 11 & 12 shaft extension

V20 Series
Dimensions in millimeters (inches)
Note: No. 1 keyed shaft and No. 38
splined shaft shown on pages 70
and 71 respectively. No. 62 splined
shaft same as V10 #11 shaft
shown above.
74,7
(2.94)

70,6
(2.78)
31,8 (1.25)

26,9 (1.06)
16,8
(.66)

50,8
(2.00)

#13 WOODRUFF KEY

37,3 (1.47)
FULL
DEPTH
OF SPLINE

26,9 (1.06)
31,8 (1.25) HEX

18,62/18,47
(.733/.727)

23,83/23,81
(.9380/.9375)

26,08/25,82
(1.0267/1.0167)
.875-18 #2 THD.

No. 3 shaft extension

19,07/19,02
(.751/.749)

INVOLUTE SPLINE 16/32 D.P.


FLAT ROOT 11 TEETH
30 PRESSURE ANGLE

No. 11 shaft extension

NOTE:
No. 3 shaft recommended nut
torque 170 Nm (125 lb. ft.)

www.Go2Hydraulics.com

72

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
V10 Single Pumps
Performance Constants:
Oil temp. 49C (120F), viscosity
32 cSt (150 SSU) @ 38C (100F),
inlet pressure zero
1 & 3 GPM RINGS
38 (10)

13,4 (18)

34 (9)

11,9 (16)
10,4 (14)

3 GPM RING
172 BAR (2500 PSI)
69 BAR(1000 PSI)
7 BAR (100 PSI)

8,9 (12)
7,4 (10)

1 GPM RING
172 BAR (2500 PSI)
69 BAR(1000 PSI)
7 BAR (100 PSI)

6,0 (8)
4,5 (6)
3,0 (4)

DELIVERY l/min (USgpm)

INPUT HORSEPOWER kW (hp)

1 & 3 GPM RINGS


14,9 ( 20)

1,5 (2)
0

3 GPM RING
172 BAR (2500 PSI)
69 BAR(1000 PSI)
7 BAR (100 PSI)

30 (8)
27 (7)
23 (6)

1 GPM RING
172 BAR (2500 PSI)
69 BAR(1000 PSI)
7 BAR (100 PSI)

19 (5)
15 (4)
11 (3)
8 (2)
4 (1)

800

1600

2400
3200
SPEED r/min

4000

4800

800

1600

2400
3200
SPEED r/min

4000

4800

2, 4 & 6 GPM RINGS


61 (16)
57 (15)
2, 4 & 6 GPM RINGS
19,4 (26)

53 (14)

17,9 (24)
INPUT HORSEPOWER kW (hp)

4 GPM RING
172 BAR (2500 PSI)

14,9 (20)
13,4 (18)
11,9 (16)

6 GPM RING
69 BAR
(1000 PSI)

10,4 (14)
8,9 (12)
7,4 (10)

2 GPM RING
172 BAR (2500 PSI)

4 GPM RING
69 BAR (1000 PSI)

6,0 (8)

DELIVERY l/min (USgpm)

45 (12)

16,4 (22)

42 (11)
38 (10)

4 GPM RING
7 BAR (100 PSI)
69 BAR (1000 PSI)
172 BAR (2500 PSI)

34 (9)
30 (8)
27 (7)
23 (6)
19 (5)
15 (4)

2 GPM RING
69 BAR (1000 PSI)

4,5 (6)

7 (2)

6 GPM RING 7 BAR (100 PSI)


4 GPM RING 7 BAR (100 PSI)
2 GPM RING 7 BAR (100 PSI)

1,5 (2)
0

800

1600

2400
3200
SPEED r/min

4000

2 GPM RING
7 BAR (100 PSI)
69 BAR (1000 PSI)
172 BAR (2500 PSI)

11 (3)

3,0 (4)

6 GPM RING
7 BAR
(100 PSI)
69 BAR
(1000 PSI)
152 BAR
(2200 PSI)

49 (13)

6 GPM RING
152 BAR (2200 PSI)

4 (1)
00

4800

800

1600

2400
3200
SPEED r/min

4000

4800

5 & 7 GPM RINGS


64 (17)
61 (16)
57 (15)

5 & 7 GPM RINGS

INPUT HORSEPOWER kW (hp)

16,4 (22)

49 (13)

14,9 (20)
13,4 (18)
11,9 (16)

7 GPM RING
138 BAR
(2000 PSI)

10,4 (14)

7 GPM RING
69 BAR (1000 PSI)

8,9 (12)
5 GPM RING
69 BAR (1000 PSI)

7,4 (10)
6,0 (8)

45 (12)
42 (11)
38 (10)
34 (9)
30 (8)

5 GPM RING
7 BAR (100 PSI)
69 BAR (1000 PSI)
172 BAR (2500 PSI)

27 (7)
23 (6)

4,5 (6)

19 (5)

3,0 (4)

15 (4)
7 GPM RING 7 BAR (100 PSI)
5 GPM RING 7 BAR (100 PSI)

1,5 (2)
0

7 GPM RING
7 BAR
(100 PSI)
69 BAR
(1000 PSI)
138 BAR
(2000 PSI)

53 (14)

5 GPM RING
172 BAR
(2500 PSI)

DELIVERY l/min (USgpm)

17,9 (24)

800

1600
2400
SPEED r/min

www.Go2Hydraulics.com

3200

11 (3)
8 (2)

800

1600
2400
SPEED r/min

3200

73

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

V20 Single Pumps


Performance Constants:
Oil temp. 49C (120F), viscosity
32 cSt (150 SSU) @ 38C (100F),
inlet pressure zero

bar (PSI) CODE

7 & 13 GPM RINGS


106 (28)

7 (100)
70 (1000)
150 (2200)

98 (26)

13
bar (PSI) CODE

91 (24)

83 (22)

83 (22)

76 (20)

76 (20)

68 (18)

11

7 (100)
70 (1000)

175 (2500)

7
61 (16)

61 (16)

53 (14)

45 (12)

38 (10)

53 (14)

45 (12)

38 (10)

30 (8)

30 (8)

23 (6)

23 (6)

15 (4)

15 (4)

8 (2)

8 (2)

0
800

1200

1600

2000

2400

2800

400

bar (PSI)

7 & 13 GPM RINGS


29,8 (40)

150 (2200) 13

26,1 (35)
22,4 (30)

175 (2500)

18,6 (25)
14,9 (20)

70 (1000) 13

11,2 (15)
70 (1000)

7,5 (10)

0
400

7 (100) 13
7 (100) 7

3,7 (5)
800

1200

1600

2000

SPEED r/min

www.Go2Hydraulics.com

2400

2800

800

CODE

1200

1600

2000

2400

9 & 11 GPM RINGS


INPUT HORSEPOWER kW (HP)

400

INPUT HORSEPOWER kW (HP)

7 (100)
70 (1000)
175 (2500)

68 (18)

7 (100)
70 (1000)
175 (2500)

DELIVERY l/min (USgpm)

DELIVERY l/min (USgpm)

9 & 11 GPM RINGS


91 (24)

2800

bar (PSI)

29,8 (40)

CODE

175 (2500) 11
175 (2500) 9

26,1 (35)
22,4 (30)
18,6 (25)
14,9 (20)

70 (1000) 11
70 (1000) 9

11,2 (15)
7,5 (10)
3,7 (5)
0
400

7 (100) 11
7 (100) 9
800

1200

1600

2000

2400

2800

SPEED r/min

74

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
V20 Single Pumps
Performance Constants:
Oil temp. 49C (120F), viscosity
32 cSt (150 SSU) @ 38C (100F),
inlet pressure zero

6, 8 & 12 GPM RINGS

bar (PSI) CODE

98 (26)
7 (100)
70 (1000)

91 (24)

12

150 (2200)
83 (22)

76 (20)
7 (100)
8

70 (1000)

DELIVERY l/min (USgpm)

68 (18)

175 (2500)
7 (100)
70 (1000)
175 (2500)

61 (16)

53 (14)

45 (12)

38 (10)

30 (8)

23 (6)

15 (4)

8 (2)

0
400

800

1200

1600

2000

2400

2800

3200

6, 8 & 12 GPM RINGS

bar (PSI) CODE

INPUT HORSEPOWER kW (HP)

29,8 (40)
150 (2200) 12

26,1 (35)
22,4 (30)

175 (2500)

175 (2500)

18,6 (25)
14,9 (20)

70 (1000) 12
70 (1000) 8
70 (1000) 6

11,2 (15)
7,5 (10)

7 (100) 12
7 (100)
8
6
7 (100)

3,7 (5)
0
400

800

1200

1600

2000

2400

2800

3200

SPEED - r/min

www.Go2Hydraulics.com

75

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Priority Valve Models


V10P Single Pumps
34 (9)

7 BAR (100 PSI)


140 BAR (2000 PSI)

CONTROLLED FLOW TO PRIORITY CIRCUIT l/min (USgpm)

30 (8)

NO. 6 ORIFICE

27 (7)
23 (6)

7 BAR (100 PSI)


140 BAR (2000 PSI)

19 (5)

NO. 3 ORIFICE

15 (4)
11 (3)
8 (2)

7 BAR (100 PSI)


140 BAR (2000 PSI)

NO. 1 ORIFICE

7 BAR (100 PSI)


140 BAR (2000 PSI)

NO. 4 ORIFICE

4 (1)
0
27 (7)
23 (6)
19 (5)
15 (4)

7 BAR (100 PSI)


140 BAR (2000 PSI)

NO. 2 ORIFICE

11 (3)
8 (2)
4 (1)
0
8
(2)

11
(3)

15
(4)

19
(5)

23
(6)

27
(7)

30
(8)

34
(9)

38
(10)

42
(11)

45
(12)

49
(13)

53
(14)

57
(15)

61
(16)

64
(17)

TOTAL PUMP DELIVERY l/min (USgpm)

V20P Single Pumps

42 (11)
NOTE: 12 & 13 RINGS
ARE RATED AT
150 BAR (2200 PSI)
PRIMARY 7 BAR (100 PSI)
SECONDARY 175 BAR (2500 PSI)
PRIMARY 175 BAR (2500 PSI)
SECONDARY 7 BAR (100 PSI)

CONTROLLED FLOW TO PRIORITY CIRCUIT l/min (USgpm)

38 (10)

34 (9)

NO. 8 ORIFICE

30 (8)

27 (7)
NO. 6 ORIFICE

23 (6)

19 (5)

15 (4)

NO. 4 ORIFICE

11 (3)

8 (2)

NO. 2 ORIFICE

4 (1)

4
(2)

15
(4)

23
(6)

30
(8)

38
(10)

45
(12)

53
(14)

61
(16)

68
(18)

76
(20)

83
(22)

91
(24)

98
(26)

106
(28)

TOTAL PUMP DELIVERY l/min (USgpm)

www.Go2Hydraulics.com

76

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance

Flow Control Models


V10F & V20F Single Pumps
34 (9)
CONTROLLED FLOW l/min (USgpm)

NO. 8 ORIFICE
30 (8)
27 (7)
23 (6)
NO. 4 ORIFICE

NO. 6 ORIFICE

19 (5)
15 (4)
11 (3)
8 (2)
NO. 2 ORIFICE
4 (1)
0
11
(3)

19
(5)

27
(7)

34
(9)

42
(11)

49
(13)

57
(15)

64
(17)

72
(19)

80
(21)

87
(23)

95
(25)

102
(27)

TOTAL PUMP DELIVERY l/min (USgpm)

Speed Correction Curves


V10 &V20 Single Pumps
0,07

0,14

Maximum operating speeds shown on


performance curves are for pumps
operating at 0 psi inlet condition. To
compute maximum operating speeds at
other inlet conditions, use appropriate
speed rating correction factor.

bar

0,17

0,10

0,07
1.06
1.04

0,28

0,34

bar

psi

1.02
in. Hg

VACUUM

2700 r/min
x .93
2511 r/min

0,21

SPEED RATING
CORRECTION
FACTOR

2
1.0

Example:
Max. speed @ 0 psi inlet
Correction factor @ 5 in. Hg
Max. speed @ 5 in. Hg inlet

0,14

0.98

2
3
4
SUPERCHARGE PRESSURE

0.96
0.94

Pump inlet suction should not exceed 5


in. Hg vacuum. Positive pressure on inlet
should not exceed 0,7 bar (10 psi).

www.Go2Hydraulics.com

77

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Double Pump Operating Specifications

Shaft end pump


Model
Series

Delivery
USgpm @
1200 r/min
7 bar
(100 psi)

Displ.
cm3/r
(in3/r)

Max.
r/min

Max.
bar
(psi)

Typical del.
L/min
(USgpm)
@ max.
speed &
pressure

Typical
input
kW (hp)
@ max.
speed &
pressure

Weight
kg
(lb)

V2010,
V2010F
&
V2010P

6
7
8
9
11
12
13

19,5 (1.19)
22,8 (1.39)
26,6 (1.62)
29,7 (1.81)
36,4 (2.22)
39,0 (2.38)
42,5 (2.59)

3000
3000
2800
2800
2500
2400
2400

172 (2500)
172 (2500)
172 (2500)
172 (2500)
172 (2500)
152 (2200)
152 (2200)

54,9 (14.5)
63,3 (16.7)
67,1 (17.7)
75,0 (19.8)
86,8 (22,9)
87,2 (23.0)
98,1 (25.9))

18,3 (24.5)
22,0 (29.5)
24,2 (32.5)
26,5 (35.5)
28,0 (37.5)
26,8 (36.0)
29,1 (39.0)

13,6 (30)

V2020,
V2020F
&
V2020P

6
7
8
9
11
12
13

19,5 (1.19)
22,8 (1.39)
26,6 (1.62)
29,7 (1.81)
36,4 (2.22)
39,0 (2.38)
42,5 (2.59)

3000
3000
2800
2800
2500
2400
2400

172 (2500)
172 (2500)
172 (2500)
172 (2500)
172 (2500)
152 (2200)
152 (2200)

54,9 (14.5)
63,3 (16.7)
67,1 (17.7)
75,0 (19,8)
86,8 (22.9)
87,2 (23.0)
98,1 (25.9)

19,4 (26.0)
22,0 (29.5)
24,2 (32.5)
26,5 (35,5)
28,0 (37.5)
26,8 (36.0)
29,1 (39.0)

15,9 (35)

Cover end pump


V2010,
V2010F
&
V2010P

1
2
3
4
5
6
7

3,3 (.20)
6,6 (.40)
9,8 (.60)
13,1 (.80)
16,4 (1.00)
19,5 (1.19)
22,8 (1.39)

3000
3000
3000
3000
3000
3000
2800

172 (2500)
172 (2500)
172 (2500)
172 (2500)
172 (2500)
152 (2200)
138 (2000)

7,6 (2.0)
17,8 (4.7)
26,5 (7.0)
36,0 (9.5)
45,4 (12.0)
55,3 (14.6)
60,6 (16.0)

3,4 (4.5)
6,7 (9.0)
10,0 (13.4)
13,4 (18.0)
16,0 (21.5)
18,3 (24.5)
17,9 (24.0)

13,6 (30)

V2020,
V2020F
&
V2020P

6
7
8
9
11

19,5 (1.19)
22,8 (1.39)
26,5 (1.62)
29,7 (1.81)
36,4 (2.22)

3000
3000
2800
2800
2500

172 (2500)
172 (2500)
172 (2500)
172 (2500)
172 (2500)

54,9 (14.5)
62,5 (16.5)
66,2 (17.5)
75,7 (20.0)
87,1 (23.0)

19,4 (26.0)
22,4 (30.0)
24,2 (32.5)
26,8 (36.0)
28,0 (37.5)

15,9 (35)

NOTE: Review Applying Vane Units page 5, prior to selection of pump.

www.Go2Hydraulics.com

78

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Model Code
V 2020 F - 1 F 13 S 11 S - 1 CC 8H 30 L
1

2
Series
V2010 or V2020
3

With no. 1 outlet opposite inlet


AA No. 2 outlet opposite inlet
AB No. 2 outlet 90  CCW from inlet
AC No. 2 outlet in line with inlet
AD No. 2 outlet 90 CW from inlet

With no. 1 outlet 90 CCW from inlet


BA No. 2 outlet opposite inlet
BB No. 2 outlet 90 CCW from inlet
BC No. 2 outlet in line with inlet
BD No. 2 outlet 90 CW from inlet

Integral valve options


(Omit if not required)
F Flow control & relief
P Priority valve & relief
Mounting
1 2-bolt flange (SAE B size pad)
6 2-bolt flange (SAE A size pad)
Inlet port connections
F 4-bolt flange 2.00 dia. (V2020)
1.50 dia. (V2010)
5

Shaft end pump


SAE rated capacity USgpm
(1200 rpm & 100 psi)
6

11 - 11 USgpm
12 - 12 USgpm
13 - 13 USgpm

No. 1 outlet port (shaft end)


S 1.062 - 12 UN-2B thd.
Cover end pump
SAE rated capacity USgpm
(1200 rpm & 100 psi)
6 6 USgpm
7 7 USgpm
8 8 USgpm V2020
9 9 USgpm
1 11 USgpm
1 1 USgpm
2 2 USgpm
3 3 USgpm
4 4 USgpm V2010
5 5 USgpm
6 6 USgpm
7 7 USgpm
8

11

11
Position of outlet
(Viewed from cover end of pump)
V2020

Vane pump

6 - 6 USgpm
7 - 7 USgpm
8 - 8 USgpm
9 - 9 USgpm

10

No. 2 Outlet port (cover end)

www.Go2Hydraulics.com

13

14

With no. 1 outlet in line with inlet


CA No. 2 outlet 135 CCW from inlet
CB No. 2 outlet 45 CCW from inlet
CC No. 2 outlet 45 CW from inlet
CD No. 2 outlet 135 CW from inlet
With no. 1 outlet 90 CW from inlet
DA No. 2 outlet 135 CCW from inlet
DB No. 2 outlet 45 CCW from inlet
DC No. 2 outlet 45 CW from inlet
DD No. 2 outlet 135 CW from inlet
12

Integral valves

Orifice No.
Relief valve setting
Flow rate
bar (psi)
l/min (USgpm)

With no. 1 outlet inline with inlet


CA No. 2 outlet opposite inlet
CB No. 2 outlet 90 CCW from inlet
CC No. 2 outlet in line with inlet
CD No. 2 outlet 90 CW from inlet

A
B
C
D
E
F

1 4 (1)
2 8 (2)
3 11 (3)
4 15 (4)
6 22 (6)
8 30 (8)

With no. 1 outlet 90 CW from inlet


DA No. 2 outlet opposite inlet
DB No. 2 outlet 90 CCW from inlet
DC No. 2 outlet in line with inlet
DD No. 2 outlet 90 CW from inlet

17 (250) G 120 (1750)


35 (500) H 140 (2000)
52 (750) J 155 (2250)
70 (1000) K 175 (2500)
86 (1250)
100 (1500)

Design
Subject to change. Installation
dimensions remain the same for
designs 10 thru 19 (V2010) and
30 thru 39 (V2020).
13

V2010
With no. 1 outlet opposite inlet
AA No. 2 outlet 135 CCW from inlet
AB No. 2 outlet 45 CCW from inlet
AC No. 2 outlet 45 CW from inlet
AD No. 2 outlet 135 CW from inlet
With no. 1 outlet 90 CCW from inlet
BA No. 2 outlet 135 CCW from inlet
BB No. 2 outlet 45 CCW from inlet
BC No. 2 outlet 45 CW from inlet
BD No. 2 outlet 135 CW from inlet

14
Shaft rotation
(Viewed from shaft end of pump)
L Left hand for counterclockwise
Omit for right hand

No. 2 Outlet port


Flow control cover
Code

Std.
cover

(See table)
10 Shafts
1 Straight keyed
3 Threaded with Woodruff key
11 Splined

12

3/4-16 St. thd.


(V2010 only)
1-1/1612
St. thd.
(V2020 only)

Pressure

Tank

Priority valve cover


Primary
outlet

Secondary
outlet

Tank

9/16-18
St. thd.
(V2010P)

3/4-16
St. thd.
(V2010P)

3/4-16
St. thd.
(V2010 &
V2020F)

1/2 NPT thd.


(V2010F &
V2020F)

3/4-16
St. thd.
(V2020P)

7/8-14
St. thd.
(V2020P)

3/4-16
St. thd.
(V2020F)

1-1/1612
St. thd.
(V2020F)

3/4-16
St. thd.
(V2010F &
V2020F)

3/4-16
St. thd.
(V2010F &
V2020F)

9/16-18
St. thd.
(V2010P)

3/4-16
St. thd.
(V2020P)

79

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions

Dimensions in millimeters (inches)

V2010 Series

Dimensions in millimeters (inches). Shaft options shown on page 83.


Rated Delivery, gpm
@ 1200 rpm & 100 psi
Shaft end
7,8 or 9
7,8 or 9
7,8 or 9
11
11
11
12 or 13
12 or 13
12 or 13

Cover end
1, 2 or 3
4 or 5
6 or 7
1, 2 or 3
4 or 5
6 or 7
1, 2 or 3
4 or 5
6 or 7

Dimensions
A
213,1 (8.39)
219,5 (8.64)
224,5 (8.84)
218,2 (8.59)
224,5 (8.84)
229,6 (9.04)
221,7 (8.73)
227,8 (8.97)
232,9 (9.17)

B
189,2 (7.45)
195,6 (7.70)
200,7 (7.90)
194,3 (7.65)
200,7 (7.90)
205,7 (8.10)
197,9 (7.79)
204,0 (8.03)
209,0 (8.23)

.500-13 UNC 2B THD.


.88 DEEP 4 HOLES

C
113,3 (4.46)
113,3 (4.46)
113,3 (4.46)
118,1 (4.65)
118,1 (4.65)
121,7 (4.79)
121,7 (4.79)
121,7 (4.79)
121,7 (4.79)

NO. 2 OUTLET PORT


.750-16 UNF 2B THD.
(SHOWN) OR .500-14 NPT
A

NO. 1 SHAFT EXTENSION


INLET PORT CONNECTION PAD IS
FOR USE WITH SAE 4-BOLT FLANGE.
SEE PAGE 119 FOR SELECTION.
NO. 1 OUTLET PORT
1.0625-12 UN-2B THD.

INLET PORT
38,1 (1.50)

CLOCKWISE
ROTATION

12,7 (.50)
A
C
26,9 (1.06)

76,2
(3.00)

45

VIEW AA

.187 SQ. KEY 1.25 LONG


66,5 (2.62)
146,1
(5.75)
120,7
73,2
(4.75)
(2.88)

58,7
(2.31)

9,4
(.37)

A
55,6 (2.19)
10
10
14,2
(.56) R.

60,5 (2.38)
55,6
(2.19)

50,8 (2.00)

14,2 (.56)
THRU
2 HOLES

24,54/24,41 (.966/.961)
101,6/101,55
(4.000/3.998)

111,2
(4.38)

22,23/22,20
(.875/.874)

V2010F Series
Dimensions in millimeters (inches). Shaft options shown on page 83.
Rated Delivery, gpm
@ 1200 rpm & 100 psi
Shaft end Cover end
1, 2 or 3
7,8 or 9
4 or 5
7,8 or 9
6 or 7
7,8 or 9
1, 2 or 3
11
4 or 5
11
6 or 7
11
1, 2 or 3
12 or 13
4 or 5
12 or 13
6 or 7
12 or 13

INLET PORT CONNECTION PAD IS


FOR USE WITH SAE 4-BOLT FLANGE.
SEE PAGE 119 FOR SELECTION.

Dimensions
A
226,1 (8.90)
232,4 (9.15)
237,5 (9.35)
230,9 (9.09)
237,2 (9.34)
242,3 (9.54)
234,4 (9.23)
240,8 (9.48)
245,9 (9.68)

B
206,8 (8.14)
213,1 (8.39)
218,2 (8.59)
211,6 (8.33)
217,9 (8.58)
223,0 (8.78)
215,1 (8.47)
221,5 (8.72)
226,6 (8.92)

C
113,3 (4.46)
113,3 (4.46)
113,3 (4.46)
118,1 (4.65)
118,1 (4.65)
121,7 (4.79)
121,7 (4.79)
121,7 (4.79)
121,7 (4.79)

.500-13 UNC 2B THD.


.88 DEEP 4 HOLES

NO. 1 OUTLET PORT


1.0625-12 UN-2B THD.

101,6/101,55
(4.000/3.998)

INLET PORT
38,1 (1.50)

TANK PORT
.750-16 UN 2B THD.
OR .500 NPT THD.

9,4 (.37)

12,7 (.50)

.187 SQ. KEY 1.25 LONG

A
NO. 2 OUTLET PORT
.750-16 UNF 2B THD.

66,5 (2.62)

B
C

45

26,9 (1.06)

VIEW AA

58,7
(2.31)

CLOCKWISE
ROTATION

121,0 (4.75)
14,2
(.56) R.

76,2
(3.00)

A
51,6 (2.03)
10
B

55,6 (2.19)

10

50,8
(2.00)

97,5 (3.84)
B

NO. 1 SHAFT EXTENSION


14,2 (.56) THRU 2 HOLES
55,6 (2.19)

VIEW BB

24,54/24,41 (.966/.961)

22,23/22,20 (.875/.874)
146,1
(5.75)

111,3 (4.38)

www.Go2Hydraulics.com

80

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions
V2010P Series
Dimensions in millimeters (inches). Shaft options shown on page 83.
Rated Delivery, gpm
@ 1200 rpm & 100 psi

Dimensions
INLET PORT CONNECTION PAD IS
FOR USE WITH SAE 4-BOLT FLANGE.
SEE PAGE 119 FOR SELECTION.

Shaft end

Cover end

7,8 or 9
7,8 or 9
7,8 or 9
11
11
11
12 or 13
12 or 13
12 or 13

1, 2 or 3
4 or 5
6 or 7
1, 2 or 3
4 or 5
6 or 7
1, 2 or 3
4 or 5
6 or 7

227,6 (8.96)
249,2 (9.21)
239,0 (9.41)
232,4 (9.15)
238,8 (9.40)
243,8 (9.60)
236,0 (9.29)
242,3 (9.54)
247,4 (9.74)

206,8 (8.14)
213,1 (8.39)
218,2 (8.59)
211,6 (8.33)
217,9 (8.58)
223,0 (8.78)
215,1 (8.47)
221,5 (8.72)
226,6 (8.92)

113,3 (4.46)
113,3 (4.46)
113,3 (4.46)
118,1 (4.65)
118,1 (4.65)
121,7 (4.79)
121,7 (4.79)
121,7 (4.79)
121,7 (4.79)

SECONDARY OUTLET
PORT .750-16 UNF-2B THD.

NO. 1 OUTLET PORT


1.0625-12 UN-2B THD.

101,6/101,55
(4.000/3.998)

INLET PORT
38,1 (1.50)
12,7 (.50)

.500-13 UNC 2B THD.


.88 DEEP 4 HOLES

61,5 (2.42)

22,23/22,20)
(.875/.874)

9,4 (3.70)

111,3 (4.38)
55,6
(2.19)

.187 SQ. KEY 1.25 LONG


14,2 (.56) THRU 2 HOLES

45
A

52,3 (2.06)

CLOCKWISE
ROTATION

58,7
(2.31)

VIEW
A-A

26,9
(1.06)

66,5 (2.62)

14,2
(.56) R.
10

55,6 (2.19)
76,2
(3.00)

A
17,5 (.69)
B

61,5 (2.42)

10

17,5 (.69)
B

VIEW
B-B

16,0 (.63)
30,2 (1.19)

121,0
(4.75)
146,1
(5.75)

NO. 1 SHAFT EXTENSION


24,54/24,41
(.966/.961)

PRIMARY OUTLET PORT


.5625-18 UNF-2B THD.
TANK PORT .5625-18 UNF-2B THD.

V2020 Series
Dimensions in millimeters (inches). Shaft options shown on page 83.
Rated Delivery, gpm
@ 1200 rpm & 100 psi
Shaft end
7,8 or 9
7,8 or 9
11
11
11
12 or 13
12 or 13
12 or 13

Cover end
6
7, 8 or 9
6
7, 8 or 9
11
6
7, 8 or 9
11

Dimensions
A
213,6 (8.41)
220,0 (8.66)
218,7 (8.61)
225,0 (8.86)
229,9 (9.05)
222,2 (8.75)
228,3 (8.99)
233,4 (9.19)

B
187,7 (7.39)
194,0 (7.64)
192,8 (7.59)
199,1 (7.84)
204,0 (8.03)
196,3 (7.73)
202,4 (7.97)
207,5 (8.17)

INLET PORT CONNECTION PAD IS


FOR USE WITH SAE 4-BOLT FLANGE.
SEE PAGE 119 FOR SELECTION.

INLET PORT
48,8/ 50,8
(1.94/2.00)

C
114,0 (4.49)
114,0 (4.49)
119,1 (4.69)
119,1 (4.69)
119,1 (4.69)
122,4 (4.82)
122,4 (4.82)
122,4 (4.82)

#2 OUTLET PORT
1.062 - 12 UN - 2B THD.

#1 INLET PORT
1.062 - 12UN 2B THD.
50,8 (2.00) R.

.500 - 13 UNC - 2B THD.


.94 DEEP 4 HOLES

12,7 (.50)

A
B
C
26,9
(1.06)
74,7 (2.94)

69,9
(2.75)

www.Go2Hydraulics.com

.187 SQ. KEY


1.25 LONG

14,2 (.56)
THRU
2 HOLES

24,54/24,41
(.966/.961)
10
10

101,6/101,55
(4.000/3.998)
NO. 1 SHAFT EXTENSION

110,5 (4.35)

9,40
(.37)

CLOCKWISE
ROTATION

66,5
(2.62)

55,6 (2.19)
55,6 (2.19)

58,7
(2.31)

146,1
(5.75)

22,23/22,20
(.875/.874)

14,2
(.56) R.
121,0 (4.75)

81

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

V2020F & V2020P Series

Dimensions in millimeters (inches). Shaft options shown on page 83.


Rated Delivery, gpm
@ 1200 rpm & 100 psi
Shaft end Cover end
6
7,8 or 9
7, 8 or 9
7,8 or 9
6
11
7, 8 or 9
11
11
11
6
12 or 13
7, 8 or 9
12 or 13
11
12 or 13

Dimensions
A
235,0 (9.25)
241,3 (9.50)
240,0 (9.45)
246,4 (9.70)
251,2 (9.89)
243,6 (9.59(
249,7 (9.83)
254,8 (10.03)

B
211,1 (8.31)
217,4 (8.56)
216,2 (8.51)
222,5 (8.76)
227,3 (8.95)
219,7 (8.65)
225,8 (8.89)
230,9 (9.09)

C
114,0 (4.49)
114,0 (4.49)
119,1 (4.69)
119,1 (4.69)
119,1 (4.69)
122,4 (4.82)
122,4 (4.82)
122,4 (4.82)

INLET PORT CONNECTION PAD IS


FOR USE WITH SAE 4-BOLT FLANGE.
SEE PAGE 119 FOR SELECTION.
49,3/50,8 (1.94/2.00)
INLET PORT
NO. 1 SHAFT EXTENSION

101,6/101,55
(4.000/3.998)
V2020F
OVERFLOW RETURN
1.062-12 UN 2B THD. OR
.750-16 UNF 2B STR. THD.
V2020P
SECONDARY OUTLET PORT
.875 14 UNF 2B STR. THD.
SAE O-RING BOSS CONNECTION

.500 13 UNC-2B THD.


23,9 (.94) DEEP
4 HOLES

#1 OUTLET PORT
1.062-12 UN 2B THD.

A
58,7
(2.31)

B
55,4
(2.18)

C
26,9 (1.06)

74,7
(2.94)

50,8
(2.00)

CLOCKWISE
ROTATION

12,7 (.50)

.187 SQ. KEY 1.25 LONG

73,2
(2.88)

9,4
(.37)

146,1
(5.75)
14,2
(.56) R.

124,0
(4.88)

10
10

V2020P
PRIMARY OUTLET PORT
.750-16 UNF 2B STR. THD.
SAE O-RING BOSS CONNECTION
15,7 (.62)

62,0 (2.44)
14,2 (.56)
THRU
2 HOLES

121,0
(4.75)

15,7 (.62)
V2020P
TANK PORT
.750-16 UNF 2B STR. THD.
SAE O-RING BOSS
CONNECTION

www.Go2Hydraulics.com

V2020F
#2 OUTLET PORT
.750-16 UNF 2B STR. THD.
SAE O-RING BOSS
CONNECTION

82

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Optional Shafts

V2010 & V2020


Dimensions in millimeters (inches)
Note: No. 1 shaft is shown on
pages 80 thru 82.

62,0
(2.44)
50,8
(2.00)
33,3
(1.31)

NO. 15 WOODRUFF KEY .250 WIDE


34,1 (1.34)
3,3 (.13)

.625 18 UNF 2A THD

25,12/24,87
(.989/.979)
4,0 (.16) THRU
22,23/22,20 (.875/.874)
29,2 (1.15)

No. 3 shaft extension

41,1
(1.62)
33,3
(1.31)
4,0
(.16)

29,2 (1.15)

17,9 (.70)

INVOLUTE SPLINE MAJOR DIA FIT


16/32 DIAMETRAL PITCH 13 TEETH
30 PRESSURE ANGLE
20,64 (.8125) PITCH DIA
19,03 (.749) TIF DIA MAX
22,13/22,15 (.873/.872) MAJOR DIA
18,16 (.715) MINOR DIA MIN

No. 11 shaft extension

www.Go2Hydraulics.com

83

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
Shaft-end Pumps
V2010 & V2020 Double Pumps
Performance Constants:
Oil temp. 49C (120F), viscosity
32 cSt (150 SSU) @ 38C (100F),
inlet pressure zero

8 & 12 GPM RINGS

bar (PSI) CODE

98 (26)

98 (26)
7 (100)
70 (1000)
150 (2200)

91 (24)

83 (22)

76 (20)

76 (20)
7 (100)
70 (1000)

53 (14)

45 (12)

30 (8)

23 (6)

23 (6)

15 (4)

15 (4)

8 (2)

8 (2)
2400

400

2800

150 (2200) 12

26,1 (35)

175 (2500) 8

22,4 (30)
18,6 (25)
14,9 (20)

70 (1000) 12

11,2 (15)

70 (1000) 8

7,5 (10)
3,7 (5)
0
400

7 (100) 12
7 (100) 8
800

1200
1600
2000
SPEED r/min

www.Go2Hydraulics.com

2400

2800

7 (100)
70 (1000)
175 (2500)

800

1200

1600

2000

2400

2800

7, 9, 11 & 13 GPM RINGS

bar (psi) CODE

8 & 12 GPM RINGS


29,8 (40)

175 (2500)

45 (12)

30 (8)

2000

11

53 (14)

38 (10)

1600

7 (100)
70 (1000)
175 (2500)

61 (16)

38 (10)

1200

13

7 (100)
70 (1000)

68 (18)
DELIVERY l/min (USgpm)

61 (16)

800

7 (100)
70 (1000)
150 (2200)

175 (2500)

INPUT HORSEPOWER kW (HP)

DELIVERY l/min (USgpm)

68 (18)

INPUT HORSEPOWER kW (HP)

91 (24)

12

83 (22)

400

bar (PSI) CODE

7, 9, 11 & 13 GPM RINGS

106 (28)

bar (psi)

29,8 (40)

CODE

150 (2200) 13
175 (2500) 11
175 (2500) 9
175 (2500) 7

26,1 (35)
22,4 (30)
18,6 (25)

70 (1000) 13
70 (1000) 11
70 (1000) 9
70 (1000) 7

14,9 (20)
11,2 (15)
7,5 (10)

7 (100) 13
7 (100) 11
7 (100) 9
7 (100) 7

3,7 (5)
0
400

800

1200

1600

2000

2400

2800

SPEED r/min

84

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
1 & 3 GPM RINGS

Cover-end Pumps

10,4 (14)
INPUT HORSEPOWER kW (hp)

V2010 Double Pumps


Performance Constants:
Oil temp. 49C (120F), viscosity
32 cSt (150 SSU) @ 38C (100F),
inlet pressure zero

3 GPM RING 175 BAR (2500 PSI)

8,9 (12)
7,4 (10)
6,0 (8)
4,5 (6)

3 GPM RING 70 BAR (1000 PSI)


1 GPM RING 175 BAR (2500 PSI)

3,0 (4)
1,5 (2)

1 GPM RING 70 BAR (1000 PSI)


3 GPM RING 7 BAR (100 PSI)
1 GPM RING 7 BAR (100 PSI)

0
0

1 & 3 GPM RINGS


17,9 (24)

3 GPM RING
7 BAR (100 PSI)
23 (6)
70 BAR (1000 PSI)
175 BAR (2500 PSI)
15 (4)

800

1600
2400
SPEED r/min

3200

2, 4 & 6 GPM RINGS


61 (16)
6 GPM RING
7 BAR (100 PSI)
70 BAR (1000 PSI)
150 BAR (2200 PSI)

53 (14)
45 (12)
38 (10)

16,4 (22)

1 GPM RING
7 BAR (100 PSI)
70 BAR (1000 PSI)
175 BAR (2500 PSI)

8 (2)
0

14,9 (20)
13,4 (18)

4 GPM RING 175 BAR (2500 PSI)

11,9 (16)
10,4 (14)
6 GPM RING 70 BAR (1000 PSI)

8,9 (12)
7,4 (10)

2 GPM RING 175 BAR (2500 PSI)


6,0 (8)

4 GPM RING
7 BAR (100 PSI)
70 BAR (1000 PSI)

4,5 (6)

175 BAR (2500 PSI)

3,0 (4)

30,3 (8)

4 GPM RING 70 BAR (1000 PSI)

2 GPM RING 70 BAR (1000 PSI)


6 GPM RING 7 BAR (100 PSI)
4 GPM RING 7 BAR (100 PSI)
2 GPM RING 7 BAR (100 PSI)

1,5 (2)

23 (6)

15 (4)

0
2 GPM RING
7 BAR (100 PSI)
70 BAR (1000 PSI)
175 BAR (2500 PSI)

8 (2)
0

3200

6 GPM RING 150 BAR (2200 PSI)

30 (8)

INPUT HORSEPOWER kW (hp)

DELIVERY l/min (USgpm)

1600
2400
SPEED r/min

2, 4 & 6 GPM RINGS

19,4 (26)

DELIVERY l/min (USgpm)

800

800

1600
2400
SPEED r/min

800

5 & 7 GPM RINGS

17,9 (24)

3200

1600
2400
SPEED r/min

3200

7 GPM RING 140 BAR (2000 PSI)

16,4 (22)
5 GPM RING 175 BAR (2500 PSI)
14,9 (20)
INPUT HORSEPOWER kW (hp)

5 & 7 GPM RINGS


68 (18)

DELIVERY l/min (USgpm)

61 (16)
53 (14)

7 GPM RING
7 BAR (100 PSI)
70 BAR (1000 PSI)
140 BAR (2000 PSI)

45 (12)
38 (10)
30 (8)
5 GPM RING
7 BAR (100 PSI)
70 BAR (1000 PSI)
140 BAR (2000 PSI)

23 (6)
15 (4)

11,9 (16)
10,4 (14)

7 GPM RING 70 BAR (1000 PSI)

8,9 (12)
7,4 (10)
5 GPM RING 70 BAR (1000 PSI)
6,0 (8)
4,5 (6)
3,0 (4)
7 GPM RING 7 BAR (100 PSI)
1,5 (2)

8 (2)
0 0

13,4 (18)

800

1600
SPEED r/min

www.Go2Hydraulics.com

2400

3200

5 GPM RING 7 BAR (100 PSI)


0

800

1600
SPEED r/min

2400

3200

85

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Cover-end pumps
V2020 Double Pumps
Performance Constants:
Oil temp. 49C (120F), viscosity
32 cSt (150 SSU) @ 38C (100F),
inlet pressure zero

bar (PSI) CODE

7, 9 & 11 GPM RINGS

98 (26)

7 (100)
70 (1000)
175 (2500)

91 (24)

83 (22)
6 & 8 GPM RINGS

7 (100)

76 (20)

76 (20)

68 (18)

175 (2500)

68 (18)

7 (100)
70 (1000)
175 (2500)

53 (14)

45 (12)

53 (14)

45 (12)

38 (10)

30 (8)

30 (8)

23 (6)

23 (6)

15 (4)

15 (4)

8 (2)

8 (2)

800

1200

1600
2000
SPEED r/min

2400

400

2800 3000

6 & 8 GPM RINGS

175 (2500) 8

22,4 (30)

175 (2500) 6

18,6 (25)
14,9 (20)
11,2 (15)

70 (1000) 8
70 (1000) 6

7,5 (10)
3,7 (5)

7 (100) 8
7 (100) 6
1200

1600

2000

SPEED r/min

www.Go2Hydraulics.com

1200

1600

2000

2400

7, 9 & 11 GPM RINGS

bar (PSI) CODE

26,1 (35)

800

800

2800 3000

SPEED r/min

29,8 (40)

0
400

61 (16)

38 (10)

400

INPUT HORSEPOWER kW (HP)

2400

2800 3000

INPUT HORSEPOWER kW (HP)

DELIVERY l/min (USgpm)

7 (100)
70 (1000)
175 (2500)

DELIVERY l/min (USgpm)

175 (2500)
61 (16)

70 (1000)

bar (PSI) CODE


7 (100)
70 (1000)

11

bar (PSI) CODE

29,8 (40)
175 (2500) 11
175 (2500) 9
175 (2500) 7

26,1 (35)
22,4 (30)
18,6 (25)
14,9 (20)

70 (1000) 11
70 (1000) 9
70 (1000) 7
7 (100) 11
7 (100) 9
7 (100) 7

11,2 (15)
7,5 (10)
3,7 (5)
0
400

800

1200

1600

2000

2400

2800 3000

SPEED r/min

86

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance

Priority Valve Models


V2010P Double Pumps
34 (9)
7 BAR (100 PSI) NO. 6 ORIFICE
140 BAR (2000 PSI)

CONTROLLED FLOW TO PRIORITY CIRCUIT l/min (USgpm)

30 (8)
27 (7)
23 (6)

7 BAR (100 PSI)NO. 3 ORIFICE


140 BAR (2000 PSI)

19 (5)
15 (4)
11 (3)

7 BAR (100 PSI) NO. 1 ORIFICE


140 BAR (2000 PSI)

8 (2)
4 (1)
0
27 (7)

7 BAR (100 PSI) NO. 4 ORIFICE


140 BAR (2000 PSI)

23 (6)
19 (5)
15 (4)

7 BAR (100 PSI)


NO. 2 ORIFICE
140 BAR (2000 PSI)

11 (3)
8 (2)
4 (1)
0
8
(2)

11
(3)

15
(4)

19
(5)

23
(6)

27
(7)

30
(8)

34
(9)

38
(10)

42
(11)

45
(12)

49
(13)

53
(14)

57
(15)

61
(16)

64
(17)

TOTAL PUMP DELIVERY l/min (USgpm)

V2020P Double Pumps


42 (11)
PRIMARY
7 BAR (100 PSI)
SECONDARY 175 BAR (2500 PSI)
PRIMARY
175 BAR (2500 PSI)
SECONDARY
7 BAR (100 PSI)

CONTROLLED FLOW TO PRIORITY CIRCUIT l/min (USgpm)

38 (10)

NO. 8 ORIFICE

34 (9)

30 (8)

27 (7)
NO. 6 ORIFICE
23 (6)

19 (5)

15 (4)

NO. 4 ORIFICE

11 (3)

8 (2)
NO. 2 ORIFICE
4 (1)

8
(2)

15
(4)

23
(6)

30
(8)

38
(10)

45
(12)

53
(14)

61
(16)

68
(18)

76
(20)

83
(22)

91
(24)

98
(26)

106
(28)

TOTAL PUMP DELIVERY l/min (USgpm)

www.Go2Hydraulics.com

87

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Flow Control Models


V2010F & V2020F Double Pumps
34 (9)

NO. 8 ORIFICE
CONTROLLED FLOW l/min (USgpm)

30 (8)
27 (7)
23 (6)

NO. 4 ORIFICE

NO. 6 ORIFICE

19 (5)
15 (4)
11 (3)
8 (2)

NO. 2 ORIFICE

4 (1)
0
11
(3)

19
(5)

27
(7)

34
(9)

42
(11)

49
(13)

57
(15)

64
(17)

72
(19)

80
(21)

87
(23)

95
(25)

102
(27)

TOTAL PUMP DELIVERY l/min (USgpm)

Speed Correction Curve


V2010 & V2020 Double Pumps

0,07

0,14

Maximum operating speeds shown on


performance curves are for pumps
operating at 0 psi inlet conditions. To
compute maximum operating speeds at
other inlet conditions, use appropriate
speed rating corrections factors shown
on the curve on the right.
Example:
Max. speed @ 0 psi inlet
2700 r/min
Correction factor @ 5 in. Hg x .93
Max. speed @ 5 in. Hg inlet 2511 r/min

bar

0,17

0,10

0,07

1.06
1.04

0,14

0,21

0,28

0,34

bar

SPEED RATING
CORRECTION
FACTOR

1.02
in. Hg

2
1.0

VACUUM

0.98

2
3
4
5
SUPERCHARGE PRESSURE

psi

0.96
0.94

Pump inlet suction should not exceed 5


in. Hg vacuum. Positive pressure on inlet
should not exceed 0,7 bar (10 psi).

www.Go2Hydraulics.com

88

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

VTM42 Power Steering Pumps

High Efficiency
Optimum running clearances and
hydraulic balance provide sustained
high efficiency throughout pump life.

Hydraulic Balance
Vickers design eliminates
pressure-induced bearing loads to
provide longer life and reduced
maintenance.

Integral Valves
Flow control and relief eliminate the
need for separate valves. Vickers
pumps supply, in one package, a
complete power source for steering.

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Operating Specifications
Model
Series

VTM42

Delivery USgpm
@ 1200 r/min
7 bar (100 psi)
1
1.5
2
4
5
6

Displ.
cm3/r
(in3/r)
3,4 (.21)
5,1 (.31)
6,2(.38)
12,9 (.79)
15,7 (.96)
19,3 (1.18)

Maximum speed - r/min


@ 7 bar
@ 100 bar
(100 psi)
(1500 psi)
7000
5000
7000
4500
7000
4200
7000
2800
6000
2600
5000
2500

@ 140 bar
(2000 psi)
4250
4000
3800
2800
2300
2000

Maximum
pressure
bar (psi)

Approx.
weight
kg (lbs.)

140
(2000)

6,4
(14)

Model Codes
1

Vane type mobile pump

Series

3
Mounting flange
A SAE A mounting flange
(Omit if not required)

Ring size - delivery


(SAE rating - 1200 rpm & 7 bar (100 psi))
40 4.0 USgpm
10 1.0 USgpm
50 5.0 USgpm
15 1.5 USgpm
60 6.0 USgpm
20 2.0 USgpm

Relief valve setting


(cracking pressure)

10

11

Shaft rotation

R Right hand (clockwise)


L Left hand (counterclockwise)

05 35 bar ( 500 psi)


07 52 bar (750 psi)
10 70 bar (1000 psi)
12 86 bar (1250 psi)
15 100 bar (1500 psi)
17 120 bar (1750 psi)
20 140 bar (2000 psi)

10

Shaft type

1 Threaded (VTM42 only)


38 Splined (VTM42A only)

15
20
25
30
35
40
45
50
55
60
65
70
75

Controlled flow rate


(at 1500 rpm & 7 bar (100 psi))
6 L/min (1.5 USgpm)
8 L/min (2 USgpm)
9,5 L/min (2.5 USgpm)
11 L/min (3 USgpm)
13 L/min (3.5 USgpm)
15 L/min (4 USgpm)
17 L/min (4.5 USgpm)
19 L/min (5 USgpm)
21 L/min (5.5 USgpm)
23 L/min (6 USgpm)
25 L/min (6.5 USgpm)
26,5 L/min (7 USgpm)
28 L/min (7.5 USgpm)

www.Go2Hydraulics.com

Design
Subject to change. Installation
dimensions remain the same for
designs 10 through 19.

F Filter instead of standard baffle.


Omit if not required.
8

11

Reservoir filter

Reservoir or manifold

07 1147 mL (70 in3) reservoir


(Omit for VTM42A)
11 1884 mL (115 in3) reservoir
(Omit for VTM42A)
MA Manifold without bypass tube
MB Manifold with bypass tube
MD Manifold with 90 tank connection
ME Cast manifold without bypass tube
MF Cast manifold with bypass tube
NO None (shipping closure only)

90

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions
VTM42 power steering
pumps with reservoir

78,5
(3.09)

Dimensions in millimeters (inches)

166,1 (6.54)

CL PUMP

174,0 (6.85)

11,2
(.44)

115 CU. IN. RESERVOIR

PULLEY NOT FURNISHED.


VEE BELT PULLEY TO BE
WITHIN THIS SPACE AND
IN LINE WITH DRIVE
PULLEY. ACCEPTABLE
DRIVES: COUPLING, BELT
OR GEAR

96,8
(3.81)

276,9
(10.90)

20,8
(.82)

115 CU. IN. RESERVOIR

70 CU. IN.
RESERVOIR

97,8
(3.85)

214,4
(8.44)

4,76 X 15,9
(.1875 X .625)
WOODRUFF KEY
STANDARD SAE
DIMENSIONS

30,0
(1.18)
28,4 (1.12)
26,9 (1.06)

66,5
(2.62)

14,2
(.56) R.

26,9
(1.06)

PUMP CL

9,7 (.38) (70 CU. IN.


RESERVOIR)

19,02/19,00
(.749/.748)

15,7 (.62)
18,3 (.72)

57,2
(2.25)
76,2
(3.00)

152,4
(6.00)

TANK CL

10,4
(.41)

45

60,5
(2.38)

136,4
(5.37)

22,4 50,8
(.88) (2.00)

RETURN CONNECTION
USE 2,3 (.62) I.D. HOSE
FASTEN WITH HOSE
CLAMPS. MUST BE AIR
TIGHT

1,0
(.04)

12,7 (.50)

57,15/57,10
(2.250/2.248)

7,1 (.28)
35,8 (1.41)

38,1 (1.50)

9,7 (.38)

PRESS CONNECTION
.750 16 UNF 2B THD.
.56 MIN DEEP
USE SAE HYDRAULIC FITTING AND
O-RING FOR .50 O.D. TUBE

108,0
(4.25)

50,8
(2.00)
74,2
(2.92) REF.

22,9
(.90)

.500-20
U.N.F.-2A THD.

106,48/106,22
(4.192/4.182)

130,0
(5.12)
.375-16 U.N.C.-2B TAP THRU
2 PLACES

78,5
(3.09)

VTM42 power steering pumps


without reservoir or manifold
Dimensions in millimeters (inches)
20,8
(.82)

PRESS CONNECTION
.750 16 UNF 2B THD.
.56 MIN DEEP
USE SAE HYDRAULIC FITTING AND
O-RING FOR .50 O.D. TUBE

50,8
(2.00)

14,2
(.56) R.

SHIPPING CLOSURE
SHOWN

39,6 (1.56)

.1875 X .625 WOODRUFF KEY


STANDARD SAE DIMENSIONS

10,4
(.41)

19,02/19,00
(.749/.748)

6,88
(2.71)
APPROX.
66,5
(2.62)

45

57,15/57,10
(2.250/2.248)
106,48/106,22
(4.192/4.182)

22,4 50,8
(.88) (2.00)

38,1 (1.50)
60,5
(2.38)

12,7 (.50)
57,2
(2.25)
76,2
(3.00)

.500-20 U.N.F.-2A THD.

7,1 (.28)
35,8 (1.41)
9,7 (.38)
108,0
(4.25)

www.Go2Hydraulics.com

1,0
(.04)

22,9
(.90)
50,8
(2.00)
74,2
(2.92) REF.

130,0
(5.12)

.375-16 U.N.C.-2B TAP


THRU 2 PLACES
PULLEY NOT FURNISHED. VEE
BELT PULLEY TO BE WITHIN
THIS SPACE AND IN LINE WITH
DRIVE PULLEY. ACCEPTABLE
DRIVES: COUPLING, BELT OR GEAR

91

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

VTM42A power steering


pumps without manifold
Dimensions in millimeters (inches)

PRESSURE CONNECTION
.75016 UNF-2B THD.
14,2 (.56) MIN. DEEP USE SAE
HYDRAULIC FITTING AND
O RING FOR .500 D. TUBE

110,2
(4.34)
14,2 (.56) R.

82,6/82,5
(3.250/3.248)

NO. 38 SHAFT
INVOLUTE SPLINE
FLAT ROOT SIDE FIT
16/32 DIAMETER FIT
11 TEETH
30 PRESSURE ANGLE
.590 MINOR DIAMETER

MANIFOLD MOUNTING
SURFACE. REFER TO
NEXT PAGE.

28,7
(1.13)

SHIPPING
CLOSURE
SHOWN

31,8
(1.25)

57,2
(2.25)
50,8
(2.00)

42,9
(1.69)

20,6
(.81)
68,8
(2.71)
APPROX.
66,5
(2.62)

106,4
(4.19)
18,62/18,47
(.733/.727)

MAJOR

38,1
(1.50)

12,7 (.50)
31,8
(1.25)
139,7
(5.50)

www.Go2Hydraulics.com

95,3
(3.75)

4,1 (.16)

11,1
(.437)
THRU
2 HOLES

130,0
(5.12)

92

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions
Manifolds for power
steering pumps
Dimensions in millimeters (inches)
MA MANIFOLD

MD MANIFOLD
50,9/50,7
(2.005/1.995)
16,7/16,4
(.656/.646)
9,7/9,4
(.380/.370)

16,7/16,4
(.656/.646)
31,9/31,6
(1.255/1.245)

9,7/9,4
(.380/.370)
PUMP CL

4,9/4,6
(.192/.182)

8,4/8,2
(.331/.321)
50,9/50,7
(2.005/1.995)

USE .621 I.D. HOSE


FASTEN WITH HOSE
CLAMP MUST BE
AIR TIGHT

TO MTG. FACE
OF PUMP

8,4/8,2
(.331/.321)
15,7
(.62)

18,3 (.72)

USE .621 I.D. HOSE


FASTEN WITH
HOSE CLAMP
MUST BE
AIR TIGHT

15,7 (.62)

104,6
(4.12)

103,9
(4.09)

TO MTG. FACE
OF PUMP

31,9/31,6
(1.255/1.245)

6,5/6,2
(.255/.245)
41,1
(1.62)

TO CL OF PUMP

4,9/4,6
(.192/.182)

18,3
(.72)
6,4
(.25)
37,3 (1.47) REF.

TO CL OF PUMP

6,4
(.25)

TO C OF PUMP
L

MF MANIFOLD

ME MANIFOLD
.750 NPT
INLET PORT

10,4
(.41)
PUMP CL

41,1
(1.62) 55,9
(2.20)

42,2 (1.66) REF

41,1
(1.62)
THIS TANK BYPASS CONN. IS
REQUIRED FOR INSTALLATIONS
WHICH OPERATE AT PUMP RELIEF
VALVE PRESSURES FOR PERIODS
EXCEEDING 15 SECONDS.
CONNECTION MUST BE MADE
BELOW OIL LEVEL IN RESERVOIR.

.250 NPT
BYPASS PORT
AVAILABLE ONLY
MF MANIFOLD

83,3
(3.28)

55,9
(2.20)

108,7
(4.28)

TO MTG. FACE
OF PUMP

12,7
(.50)

42,2 (1.66) REF

TO CL OF PUMP

TO CL OF PUMP

.750 NPT
INLET PORT

PUMP CL

TO MTG. FACE
OF PUMP

12,7
(.50)

108,7
(4.28)

TO CL OF PUMP

MB MANIFOLD

6,5/6,2
(.255/.245)

9,7/9,4
(.380/.370)

31,9/31,6
(1.255/1.245)

PUMP CL

8,4/8,2
(.331/.321)

10,4
(.41)

6,5/6,2
(.255/.245)

50,9/50,7
(2.005/1.995)

USE .621 I.D. HOSE


FASTEN WITH
HOSE CLAMP 18,3 (.72)
15,7 (.62)
MUST BE
AIR TIGHT
6,4

4,9/4,6
16,7/16,4 (.192/.182)
(.656/.646)
A

TO MTG. FACE
OF PUMP

Manifold
Code

9,4 (.37)
7,9 (.31)

(.25)

104,6
(4.12)
TO CL OF PUMP

www.Go2Hydraulics.com

96,0
(3.78)
TO CL OF PUMP

THIS TANK BYPASS CONN. IS REQUIRED FOR


INSTALLATIONS WHICH OPERATE AT PUMP
RELIEF VALVE PRESSURES FOR PERIODS
EXCEEDING 15 SECONDS. CONNECTION MUST
BE MADE BELOW OIL LEVEL IN RESERVOIR.

MA
MB
MD
ME
MF

Dimension A
VTM42
VTM42A
47,0
(1.85)

78,7
(3.10)

75,9
(2.99)

107,7
(4.24)

93

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance

1.5 GPM RING

1 GPM RING

27 (7)

DELIVERY L/min (USgpm)

38 (10)
PUMP DELIVERY TOTAL

19 (5)
15 (4)
11 (3)

5,7 L/min (1.5 USgpm) ORIFICE

8 (2)
4 (1)

100 BAR
(1500 PSI)
70 BAR
(1000 PSI)

140 BAR (2000 PSI)


MAX. PRESS.
& SPEED

4,50 (6)
3,73 (5)
2,98 (4)

140 (2000)

2,24 (3)

100 (1500)
7 BAR
(100 PSI)

70 (1000)
35 (500)
0

5,22 (7)

1000

2000 3000 4000

1,49 (2)
0,75 (1)

5000

0
6000 7000

SPEED r/min

30 (8)

PUMP DELIVERY TOTAL

27 (7)
23 (6)
19 (5)

9,7 L/min (2.5 USgpm) ORIFICE


7,6 L/min (2.0 USgpm) ORIFICE
5,7 L/min (1.5 USgpm) ORIFICE

15 (4)
11 (3)
8 (2)
4 (1)
0

100 BAR (1500 PSI)


5,22 (7)

140 BAR (2000 PSI)


PRESSURE bar (psi)

34 (9)

MAX. PRESS.
& SPEED

4,50 (6)
70 BAR
1000 PSI)

140 (2000)

2,98 (4)
2,24 (3)

100 (1500)
70 (1000)

1,49 (2)

7 BAR
(100 PSI)

35 (500)
0
0

3,73 (5)

1000

0,75 (1)

2000 3000 4000

0
6000 7000

5000

INPUT HORSEPOWER kW (hp)

23 (6)

INPUT HORSEPOWER kW (hp)

PRESSURE bar (psi)

DELIVERY L/min (USgpm)

VTM42(A)
power steering pumps

SPEED r/min

38 (10)

34 (9)

34 (9)

30 (8)

DELIVERY L/min (USgpm)

PUMP DELIVERY TOTAL

27 (7)
23 (6)

11,4 L/min (3.0 USgpm) ORIFICE


9,5 L/min (2.5 USgpm) ORIFICE
7,6 L/min (2.0 USgpm) ORIFICE
5,7 L/min (1.5 USgpm) ORIFICE

19 (5)
15 (4)
11 (3)
8 (2)
4 (1)
0

23 (6)

9,5 L/min (2.5 USgpm) ORIFICE


7,6 L/min (2.0 USgpm) ORIFICE
5,7 L/min (1.5 USgpm) ORIFICE

19 (5)
15 (4)
11 (3)
8 (2)

70 BAR
(1000 PSI)

5,22 (7)
4,50 (6)

MAX. PRESS.
& SPEED

140 (2000)

3,73 (5)
2,98 (4)

100 (1500)

2,24 (3)
70 (1000)

7 BAR
(100 PSI)

35 (500)
0

1000

2000 3000 4000


SPEED r/min

1,49 (2)
0,75 (1)
5000

0
6000 7000

10,44 (14)

140 BAR (2000 PSI)

9,69 (13)
8,95 (12)
8,20 (11)

100 BAR (1500 PSI)

7,46 (10)
70 BAR (1000 PSI)

6,71 (9)
5,97 (8)
5,22 (7)
4,50 (6)

PRESSURE bar (psi)

5,97 (8)

INPUT HORSEPOWER kW (hp)

7,46 (10)
6,71 (9)

100 BAR
(1500 PSI)
PRESSURE bar (psi)

27 (7)

4 (1)
8,20 (11)

140 BAR (2000 PSI)

PUMP DELIVERY TOTAL

30 (8)

MAX. PRESS. & SPEED


7 BAR
(100 PSI)

140 (2000)

3,73 (5)
2,98 (4)

100 (1500)

2,24 (3)

70 (1000)

1,49 (2)

35 (500)

0,75 (1)

1000

2000

3000

4000

5000

6000

INPUT HORSEPOWER kW (hp)

DELIVERY L/min (USgpm)

4 GPM RING

2 GPM RING

38 (10)

0
7000

SPEED r/min

www.Go2Hydraulics.com

94

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
VTM42(A)
Power Steering Pumps

6 GPM RING
38 (10)

5 GPM RING
DELIVERY L/min (USgpm)

34 (9)
30 (8)
PUMP DELIVERY TOTAL

27 (7)
23 (6)
19 (5)
15 (4)
11 (3)

15,1 L/min (4.0 USgpm) ORIFICE


13,2 L/min (3.5 USgpm) ORIFICE
11,4 L/min (3.0 USgpm) ORIFICE

8 (2)
4 (1)

27 (7)
23 (6)
19 (5)
28,4 L/min (7.5 USgpm) ORIFICE
24,6 L/min (6.5 USgpm) ORIFICE
20,8 L/min (5.5 USgpm) ORIFICE
17,0 L/min (4.5 USgpm) ORIFICE

15 (4)
11 (3)
8 (2)
4 (1)
0

0
140 BAR (2000 PSI)

100 BAR (1500 PSI)


70 BAR
(1000 PSI)

7,46 (10)
6,71 (9)
5,97 (8)

PRESSURE bar (psi)

5,22 (7)
4,50 (6)

MAX. PRESS.
& SPEED

3,73 (5)

140 (2000)

2,98 (4)

100 (1500)

2,24 (3)
7 BAR
(100 PSI)

70 (1000)

1,49 (2)
0,75 (1)

35 (500)
0

1000

2000

3000

4000

SPEED r/min

www.Go2Hydraulics.com

5000

0
6000

8,95 (12)
8,20 (11)
7,46 (10)
6,71 (9)
5,97 (8)
5,22 (7)
4,50 (6)

PRESSURE bar (psi)

70 BAR (1000 PSI)

INPUT HORSEPOWER kW (hp)

8,95 (12)
8,20 (11)

10,44 (14)
9,69 (13)

9,69 (13)

100 BAR (1500 PSI)

11,20 (15)

140 BAR (2000 PS)I


10,44 (14)

MAX. PRESS.
& SPEED

3,73 (5)
2,98 (4)

140 (2000)

2,24 (3)

100 (1500)
7 BAR
(100 PSI)

70 (1000)

1,49 (2)
0,75 (1)

35 (500)
0

INPUT HORSEPOWER kW (hp)

DELIVERY L/min (USgpm)

38 (10)

PUMP
34 (9) DELIVERY
TOTAL
30 (8)

1000

2000

3000

4000

0
5000

SPEED r/min

95

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Vane Motors 21,6 to 37,5 cm3/r (1.32 to 2.29 in3/r)

Characteristics

Hydraulic Balance

Smooth Operation

An economical, efficient and compact


means of applying variable speed, rotary
hydraulic power, these motors have
variable horsepower (constant torque)
characteristics. They can be stalled
under load without damage when
protected by a relief valve.

Two internal inlet chambers are


diametrically opposed as are two outlet
chambers. This construction eliminates
bearing loads resulting from pressure, a
major cause of wear in designs without
this feature.

Inertia of rotating parts is low ... parts are


symmetrical, providing dynamic balance
and freedom from vibration.

Efficiency
Optimum running clearances and
hydraulic balance assure sustained high
efficiency over the life of the motor.

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Operating Specifications

Model
series
M2U

M2210

Torque
Nm/6,9 bar
(lb. in./100 psi)
2,0 (18)
2,8 (25)
4,0 (35)
2,8 (25)
4,0 (35)

Displ.
cm3/r
(in3/r)
21,6 (1.32)
25,4 (1.55)
37,5 (2.29)
24,7 (1.51)
35,4 (2.16)

Maximum torque
Nm (lb. in.) @
max. pressure
38,4 (340)
46,3 (410)
67,8 (600)
46,3 (410)
56,5 (500)

Maximum speeds
& pressures
2800 r/min @ 138 bar (2000 psi)
2500 r/min @ 138 bar (2000 psi)
2000 r/min @ 138 bar (2000 psi)
2200 r/min @ 138 bar (2000 psi)
1800 r/min @ 121 bar (1750 psi)

Approx.
weight
lbs.
7,7
(17)
9,5
(21)

Model Codes
M 2 U - 1 S 35 S - 1 C 10 L
1

Vane motor

Series

Uni-directional rotation

10

11

9
Outlet position
(Viewing cover end)

Ring size torque

(lb. in./100 psi)


18, 25 and 35

A Outlet port opposite inlet


C Port connections inline

Outlet port
S 1-5/16 12 st. thd.

Mounting
1 2-bolt flange
5

Design
Subject to change. Installation
dimensions remain the same for
designs 10 through 19.
10

Shaft type

1 Straight keyed
3 Threaded
11 Splined

Inlet port

S 1-5/16 12 st. thd.

11
Rotation
L Left hand (counterclockwise)
Omit for right hand (clockwise)

M 2 - 2 1 0 - 35 - 1 C - 13
1

Vane motor

Series (bi-directional rotation)

1-3/4 NPT both ports


5
Mounting
0 2 bolt flange

www.Go2Hydraulics.com

Ring size torque


lb. in./100 psi
25 and 35

Series frame size


Porting

7
4

1
3
6
11

Shaft type
Straight keyed
Threaded
Straight keyed (stub)
Splined

8
Cover position
(Viewing cover end)

A Cover port opposite body port


B Cover port 90 CCW from
body port
C Port connections in line
D Cover port 90 CW from
body port
Design
Subject to change. Installation
dimensions remain the same for
designs 10 through 19.
9

97

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions

M2U series
Dimensions in millimeters (inches)
Shaft options shown on page 99.
OUTLET PORT
1.3125-12 UN-2B THD.
FOR SAE HYDRAULIC FITTING
USED WITH 1 O.D. TUBING

Dimensions
A
B

Model

M2U1S18S-1C10 129,8 (5.11) 105,4 (4.15)


M2U1S25S-1C10 136,1 (5.36) 111,8 (4.40)
M2U1S35S-1C10 141,0 (5.55) 116,6 (4.59)

#1 SHAFT

INLET PORT
1.3125-12 UN-2B THD.
FOR SAE HYDRAULIC FITTING
USED WITH 1 O.D. TUBING

12,7 (.50)
A

52,3
(2.06)

52,3
(2.06)
C

62,0
(2.44) 53,8
(2.12)

CLOCKWISE
ROTATION

11,1 (.438)
2 HOLES

67,6
(2.66)
4,1 (.16)
41,1
(1.62)

34
(1.34)

 4,8 (.1875)
KEY
21,13/21,00
(.832/.827)

124,0
(4.88)

19,05/19,02
(.750/.749)

82,55/82,50
(3.250/3.248)

82,55/82,50
(3.250/3.248)

ARROW ON RING INDICATES ROTATION

47,8 (1.88) R.
130,0 (5.12)

35 INDICATES LB. IN. TORQUE PER 100 PSI

M2-200 series
Dimensions in millimeters (inches)
Shaft options shown on page 99.

CONNECTION K
3/4 NPT

CONNECTION L
3/4 NPT

Fluid supply to connection L provides


clockwise shaft rotation, viewed from
shaft end.
Fluid supply to connection K provides
counterclockwise shaft rotation.

12,7 (.50)
106,4
(4.19)

53,1
(2.09)

71,8
(2.81)

4,1 (.16)
67,6
(2.66)

149,9
(5.90)
37,3
(1.47)

41,1
(1.62)

106,4
(4.19)
B

21,13/21,00
(.832/.827)

122,9
53,1 (4.84)
(2.09)

#1 SHAFT
 4,788/4,7625
(.1885/.1875)
KEY
95,3
(3.75)

50,8 (2.00)

www.Go2Hydraulics.com

DRAIN CONNECTION
3/8 PIPE THD

106,27/106,47
(4.184/4.192)

82,55/82,50
(3.250/3.248)

19,05/19,02
(.750/.749)

32,5 (1.28)
A

CLOCKWISE
ROTATION

.438 DIA 2 HOLES


FOR MOUNTING

53,1
(2.09)
130,0
(5.12)

98

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Optional Shafts

M2U & M2-200 series


Dimensions in millimeters (inches)
70,6
(2.78)

26,9 (1.06)

74,7
(2.94)
50,8
(2.00)

31,8 (1.25)
#13 WOODRUFF KEY

16,8
(.66)

37,3
(1.47)

9,7 (.38)

FULL DEPTH
OF SPLINE
INVOLUTE SPLINE
16/32 D.P.
FLAT ROOT 11 TEETH
30 PRESSURE ANGLE

6,4 (.25)

26,9
(1.06)

31,8 (1.25) HEX


19,08/19,02

26,08/25,82
(1.0267/1.0167)

23,83/23,81

(.751/.749)

18,62/18,47

.875-18 #2 THD.

(.9380/.9375)

(.733/.727)

No. 3 threaded shaft

No. 11 splined shaft

NOTE:
Nut torque 169,5 Nm (125 lb. ft.)

M2-200 series
Dimensions in millimeters (inches)
Note: No. 1 keyed shaft is shown
on page 98.
31,8
(1.25)
12,7
(.50)

#9 WOODRUFF KEY

21,25/21,00
(.8368/.8268)

19,01/19,00
(.7485/.7480)
6,4 (.25)

18,3 (.72)

12,7 (.50) FLAT

No. 6 straight stub shaft

www.Go2Hydraulics.com

99

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
M2U Series
Performance Constants:
Oil temp. 49C (120F), viscosity
32 cSt (150 SUS) @ 38C (100F)

18 LB. IN. RING


138 bar (2000 psi)
103 bar (1500 psi)
69 bar (1000 psi)
34 bar (500 psi)

68 (18)
61 (16)
Volume required L/min (USgpm)

25 LB. IN. RING


138 bar (2000 psi)
103 bar (1500 psi)
69 bar (1000 psi)
34 bar (500 psi)

76 (20)
68 (18)

52 (14)
Volume required L/min (USgpm)

61 (16)

45 (12)
38 (10)
30 (8)
23 (6)
15 (4)
8 (2)

52 (14)
45 (12)
38 (10)
30 (8)
23 (6)
15 (4)

400

800 1200 1600 2000 2400 2800


Speed r/min

8 (2)

138 bar (2000 psi)


103 bar (1500 psi)
69 bar (1000 psi)
34 bar (500 psi)

11,9 (16)
8,9 (12)
6,0 (8)
3,0 (4)
0
0

400

800 1200 1600 2000 2400 2800


Speed r/min

138 bar (2000 psi)


103 bar (1500 psi)

56,5 (500)
45,2 (400)
33,9 (300)
22,6 (200)
11,3 (100)
0

400

800 1200 1600 2000 2400


Speed r/min

138 bar (2000 psi)


103 bar (1500 psi)
69 bar (1000 psi)
34 bar (500 psi)
0

400

800 1200 1600 2000 2400


Speed r/min

69 bar (1000 psi)


34 bar (500 psi)
400

800 1200 1600 2000 2400 2800


Speed r/min

Power kW (hp)

Torque Nm (lb in)

0
45,2 (400)
33,9 (300)
22,6 (200)
11,3 (100)
0

Power kW (hp)

Torque Nm (lb in)

14,9 (20)
103 bar (1500 psi)

6,0 (8)
3,0 (4)
0

www.Go2Hydraulics.com

138 bar (2000 psi)

11,9 (16)
8,9 (12)

69 bar (1000 psi)


34 bar (500 psi)
0

400

800

1200 1600 2000 2400


Speed r/min

100

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance

M2U Series
Performance Constants:
Oil temp. 49C (120F), viscosity
32 cSt (150 SUS) @ 38C (100F)

35 LB. IN. RING


138 bar (2000 psi)

83 (22)

103 bar (1500 psi)


69 bar (1000 psi)
34 bar (500 psi)

76 (20)

68 (18)

Volume required L/min (USgpm)

61 (16)

52 (14)

45 (12)

38 (10)

30 (8)

23 (6)

15 (4)

8 (2)

400

800

1200

1600

2000

Speed r/min

Torque Nm (lb in)

67,8 (600)

138 bar (2000 psi)

56,5 (500)
103 bar (1500 psi)

45,2 (400)
33,9 (300)

69 bar (1000 psi)

22,6 (200)
34 bar (500 psi)

11,3 (100)
0

Power kW (hp)

400

800
1200
Speed r/min

1600

2000

138 bar (2000 psi)

14,9 (20)
11,9 (16)

103 bar (1500 psi)

8,9 (12)
6,0 (8)

69 bar (1000 psi)

3,0 (4)

34 bar (500 psi)

0
0

www.Go2Hydraulics.com

400

800
1200
Speed r/min

1600

2000

101

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

M2-200 Series
Performance Constants:
Oil temp. 49C (120F), viscosity
32 cSt (150 SUS) @ 38C (100F)

61 (16)

35 LB. IN. RING


138 bar (2000 psi)
103 bar (1500 psi)
69 bar (1000 psi)
34 bar (500 psi)

52 (14)
45 (12)
38 (10)
30 (8)
23 (6)
15 (4)
8 (2)
0
0

400

800
1200 1600
Speed r/min

2000 2200

76 (20)
Volume required L/min (USgpm)

Volume required L/min (USgpm)

25 LB. IN. RING

61 (16)
52 (14)
45 (12)
38 (10)
30 (8)
23 (6)
15 (4)
8 (2)
0

400

800
1200
Speed r/min

1600

56,5 (500)
45,2 (400)

138 bar (2000 psi)

33,9 (300)

103 bar (1500 psi)

22,6 (200)

69 bar (1000 psi)

11,3 (100)
0

34 bar (500 psi)


0

400

800
1200
1600
Speed r/min

2000 2200

Torque Nm (lb in)

Torque Nm (lb in)

121 bar (1750 psi)


103 bar (1500 psi)
69 bar (1000 psi)
34 bar (500 psi)

68 (18)

56,5 (500)
45,2 (400)

121 bar (1750 psi)


103 bar (1500 psi)

33,9 (300)

69 bar (1000 psi)

22,6 (200)

103 bar (1500 psi)

6,0 (8)

69 bar (1000 psi)

3,0 (4)
0

400

800
1200
Speed r/min

1600

138 bar (2000 psi)

8,9 (12)

34 bar (500 psi)


0

400

800
1200
1600
Speed r/min

2000 2200

Power kW (hp)

Power kW (hp)

0
11,9 (16)

34 bar (500 psi)

11,3 (100)

11,9 (16)
8,9 (12)

121 bar (1750 psi)


103 bar (1500 psi)

6,0 (8)

69 bar (1000 psi)

3,0 (4)

34 bar (500 psi)

www.Go2Hydraulics.com

400

800
1200
Speed r/min

1600

102

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

High Speed - High Pressure Motors


from 43,9 to 317,1 cm3/r (2.68 to 19.35 in3/r)

Reliable

Series Operation

High Speed and Pressure

Vickers has field-proved these high


performance motors over many years.
They have been overwhelmingly
successful on elevator scraper drives,
hydrostatic drives and many other
auxiliary applications.

Inlet and outlet ports can be pressurized


simultaneously without affecting service
life or operating smoothness. These
motors are suited to series applications.
See note below table on page 104
regarding pressure/rotation of model
series 50M.

These motors offer speeds to 3000 rpm


at maximum pressure. Speeds up to
4000 rpm are obtainable, as in
transmission applications where high
travel speeds under light loads are
required.

Efficient
Vickers exclusive dual-alternate
pressure plate design provides overall
efficiency of about 86%.

Reversibility
Through the dual plate design, the
motors may be reversed simply by
reversing the direction of oil flow. See
note below table on page 104 regarding
pressure/rotation of model series 50M.

www.Go2Hydraulics.com

Replaceable Cartridge
Replaceable cartridges permit motor
overhauls in just 10 minutes - in the
field! A cartridge can be replaced without
removing the unit from the vehicle, and
usually without disconnecting hydraulic
lines.

103

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Operating Specifications

Torque
Model Nm/6,9 bar
Series (lb.in./100 psi)
25M

35M

45M

50M

Displacement
cm3/r (in3/r)

Flow Input
@ 1200 r/min
L/min (USgpm)

Max. Torque
Nm (lb.in.) @
Max. Pressure

4,7 (42)
6,2 (55)
7,3 (65)

43,9 (2.68)
57,7 (3.52)
68,7 (4.19)

52,7 (13.9)
69,4 (18.3)
82,6 (21.8)

115,8 (1025)
151,4 (1340)
180,8 (1600)

9,0 (80)
10,7 (95)
13,0 (115)

83,6 (5.10)
100,3 (6.12)
121,9 (7.44)

100,4 (26.5)
120,5 (31.8)
146,3 (38.6)

221,5 (1960)
264,4 (2340)
320,9 (2840)

14,7 (130)
17,5 (155)
20,9 (185)

138,0 (8.42)
163,2 (9.96)
193,2 (11.79)

165,6 (43.7)
195,9 (51.7)
232,3 (61.3)

361,6 (3200)
429,4 (3800)
502,9 (4450)

24,9 (220)
28,8 (255)
33,9 (300)

231,3 (14.11)
268,2 (16.36)
317,2 (19.35)

277,8 (73.3)
322,2 (85.0)
380,7 (100.5)

615,9 (5450)
717,6 (6350)
844,1 (7470)

Maximum
Speeds & Pressure

Approx.
Weight
kg (lb)
18 (40)

4000 r/min @ 34 bar (500 psi)


29 (64)
3000 r/min @ 172 bar (2500 psi)
39 (85)

3200 r/min @ 34 bar (500 psi)


2400 r/min @ 172 bar (2500 psi)

73 (160)

114 suffix: 2500 psi, counterclockwise


2250 psi, clockwise
124 suffix: 2500 psi, bi-directional

NOTE: Review Applying Vane Units page 5, prior to selection of motors.

Model Codes
25 M 65 A - 11 C - 20 - ***
1

Series

25M
35M
45M
50M
26M
36M
46M
51M
2

Standard
bearing

Mounting flange &


port connections

A SAE type 2-bolt mounting flange and


SAE 4-bolt flange connections
5

Heavy duty
bearing

Vane motor

Ring size - Nominal torque rating


(lb. in./100 psi)
3

25M 42, 55 & 65


35M 80, 95 & 115
45M 130, 155 & 185
50M 220, 255 & 300

www.Go2Hydraulics.com

Shaft
1 Straight keyed
11 Splined

7
Design
Subject to change. Installation
dimensions remain the same for
designs 20 through 29.

114
124

Special features suffix


50M only

6 Cover position
(Viewing cover end)

A Cover port opposite body port


B Cover port 90 CCW from
body port
C Port connections in line
D Cover port 90 CW from
body port
NOTE: For internal drain, side port
case drain, and other options, contact
your Vickers representative.

104

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Installation Dimensions
25M Motors
Dimensions in millimeters (inches)
Shaft options shown on page 107.
Port connection pads are for use
with SAE 4-bolt flanges. See page
119 for selection.

#11 SHAFT
SAE INVOLUTE SPLINE DATA
FLAT ROOTMAJOR DIA FIT
16/32 DIAMETRAL PITCH
13 TEETH 30
PRESSURE ANGLE
.749 T.I.F. DIA
.8125 PITCH DIA

CONNECTION L
31.75 (1.25) PORT

CONNECTION K
31.75 (1.25) PORT

12,7 .50)

Fluid supply to connection L turns


shaft clockwise as viewed from
shaft end. Fluid supply to connection
K turns shaft counterclockwise.

101,60/101,55
(4.000/3.998)

.4375 14 UNC-2B THD


19,1 (.750) DEEP 8 HOLES
1/4 NPT 18 THD DRAIN CONNECTION
DO NOT RESTRICT
117,3 (4.62)
C

CLOCKWISE ROTATION

9,65/9,14
(.380/.360)
182,4 (7.18)
144,3 (5.68)
39,6 (1.56)

58,7 (2.31)
76,2
(3.00)

174,8 (6.88)

44,5 (1.75)
33,3 (1.31)

1,5
(.06)
13,5
(.53)

120,7
(4.75)

146,1 (5.75)

134,9
(5.31)

27,8 (1.09)
14,2 (.56) THRU
2 HOLES

22,17/22,15 (.873/.872) MAJOR


18,16 (.715) MIN MINOR
CONNECTION K
38,1 (1.5) PORT

35M Motors

CONNECTION L
38,1 (1.5) PORT

Dimensions in millimeters (inches)


Shaft options shown on page 107.
Port connection pads are for use
with SAE 4-bolt flanges. See page
119 for selection.
Fluid supply to connection L turns
shaft clockwise as viewed from shaft
end. Fluid supply to connection K
turns shaft counterclockwise.
3/8 NPT 18 THD
DRAIN CONNECTION
DO NOT RESTRICT

69,9 (2.75)
88,9
(3.50)

127,00/126,95
(5.000/4.998)
#11 SHAFT
SAE INVOLUTE SPLINE DATA
FLAT ROOTMAJOR DIA FIT
12/24 DIAMETRAL PITCH
14 TEETH 30
PRESSURE ANGLE
1.082 T.I.F. DIA
1.1667 PITCH DIA

15,7 (.62)

139,7
(5.50)

.500 13 UNC-2B THD


22,2 (.875) DEEP 8 HOLES

211,1 (8.31)
170,7 (6.72)
48,3 (1.90)

12,7/12,2
(.500/.480)

CLOCKWISE ROTATION

62,0 (2.44)
47,6 (1.875)
1,5
(.06)
9,7
(.38)

8.38
5.81
DIA.

181,1
(7.13)

158,8
(6.25)

www.Go2Hydraulics.com

35,1 (1.38)
17,5 (.688)
THRU 2 HOLES
31,70/31,67 (1.248/1.247) MAJOR

26,42
(1.040) MIN MINOR

105

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

45M Motors

CONNECTION K

#11 SHAFT
SAE INVOLUTE SPLINE DATA
FLAT ROOT MAJOR DIA FIT
12/24 DIAMETRAL PITCH
14 TEETH
30 PRESSURE ANGLE
1.0822 T.I.F. DIA
1.1667 PITCH DIA

CONNECTION L
50,8 (2.00) PORT

Dimensions in millimeters (inches)


50,8 (2.00) PORT
Shaft options shown on page 107.
Port connection pads are for use with
SAE 4-bolt flanges. See page 119 for
selection.

127,00/126,95
(5.000/4.998)

Fluid supply to connection L turns shaft


clockwise as viewed from shaft end.
Fluid supply to connection K turns
shaft counterclockwise.
.500 13 UNC 28 THD
22,2 (.875) DEEP 8 HOLES
15,7 (.62)

1/2 NPT 14 THD DRAIN CONNECTION


DO NOT RESTRICT

12,7/12,2
(.500/.480)

249,2 (9.81)

158,8 (6.25)
79.2
(3.12)
C

1,5
(.06)
93,5
(3.68)

212,9 (8.38)

62,0 (2.44)

197,9 (7.79)
52,8 (2.08)

CLOCKWISE ROTATION

147,6 (5.81)

47,8 (1.88)

9,7
(.38)

181,1
(7.13)

39,6
(1.56)

173,0
(6.81)

17,5 (.688) THRU


2 HOLES
31,70/31,67
(1.248/1.247)
MAJOR

CONNECTION K 63,5 (2.50) PORT


FLUID SUPPLY TO CONNECTION
K TURNS SHAFT COUNTERCLOCKWISE

CONNECTION L 63,5 (2.50) PORT


FLUID SUPPLY TO CONNECTION
L TURNS SHAFT CLOCKWISE

50M Motors

.500 13 UNC 2B THD


1.19 DEEP 8 HOLES

Dimensions in millimeters (inches)


Shaft options shown on page 107.
Port connection pads are for use with
SAE 4-bolt flanges. See page 119 for
selection.

152,40/152,35
(6.000/5.998)
101,6
(4.00)

Fluid supply to connection L turns shaft


clockwise as viewed from shaft end. Fluid
supply to connection K turns shaft
counterclockwise.
1/2 NPT 14 THD
DRAIN CONNECTION
DO NOT RESTRICT

22,4 (.88)

12,7/12,2
(.500/.480)

294,9 (11.61)

196,9
(7.75)
C

231,9 (9.13)

98,6
(3.88)

74,4
(2.93)

#11 SHAFT
SAE INVOLUTE
SPLINE DATA
FLAT ROOT
SIDE DIA FIT
8/16 DIAMETRAL PITCH
13 TEETH
30 PRESSURE ANGLE
1.501 T.I.F. DIA
1.6250 PITCH DIA

CLOCKWISE ROTATION

200,2
(7.88)

69,9 (2.75)
120,7
(4.75)

26,42 (1.040)
MIN MINOR

266,7
(10.50)

66,8
(2.63)
6,35
(.25)

228,6
(9.00)
47,5
(1.87)

219,7
(8.65)
A

1,5
(.06)
REF

36,6 (1.44)
20,6 (.81)
THRU
2 HOLES
43,71/43,56
(1.721/1.715) MAJOR

www.Go2Hydraulics.com

36,63 (1.442) MIN


MINOR

106

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Optional Shafts
25M series

35M & 45M series

No. 1 straight keyed shaft


Dimensions in millimeters (inches)

No. 1 straight keyed shaft


Dimensions in millimeters (inches)

58,7
(2.31)
47,8
(1.88)
1,5
(.06)
REF
31,8
(1.25)

 4,75 (.187)
KEY

28,4
(1.12)

24,46/24,31
(.963/.957)

 7,92 (.312) KEY


35,18/34,93
(1.385/1.375)

27,8
(1.093)

22,23/22,20
(.875/.874)

35,1
(1.38)
47,8
(1.88)

35,18/34,93
(1.250/1.248)

1,5 (.06)
REF
62,0
(2.44)

50M series
No. 1 straight keyed shaft
Dimensions in millimeters (inches)
 11,10 (.437) KEY
50,8
(2.00)

49,38/49,12
(1.944/1.934)
47,5
(1.87)
44,45/44,42
(1.750/1.749)

66,8
(2.63)
1,5 (.06)
REF
74,4
(2.93)

www.Go2Hydraulics.com

107

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
42 LB. IN. MODEL

25M Motors
Performance Constants:
Oil SAE 10W,
viscosity 32 cSt (150 SUS)
@ 38C (100F)

265 (70)
227 (60)
175 BAR (2500 PSI)
140 BAR (2000 PSI)
70 BAR (1000 PSI)
35 BAR (500 PSI)

189 (50)
151 (40)

265 (70)
227 (60)

114 (30)

189 (50)

76 (20)

151 (40)

38 (10)

175 BAR (2500 PSI)


140 BAR (2000 PSI)
70 BAR (1000 PSI)
35 BAR (500 PSI)

114 (30)
76 (20)
38 (10)
0

TORQUE

113,0 (1000)

175 BAR
(2500 PSI)

90,4 (800)

140 BAR
(2000 PSI)

67,8 (600)

70 BAR (1000 PSI)

22,6 (200)

55 LB. IN. MODEL

29,8 (40)
22,4 (30)
14,9 (20)

45,2 (400)

37,3 (50)

Power kW (hp)

Torque Nm (lb.in)

135,6 (1200)

7,5 (10)

35 BAR (500 PSI)


0

800

1600

2400

3200

0
4000

SPEED r/min

265 (70)
227 (60)

175 BAR (2500 PSI)


140 BAR (2000 PSI)
70 BAR (1000 PSI)
35 BAR (500 PSI)

189 (50)

265 (70)

151 (40)

227 (60)

114 (30)

189 (50)

76 (20)

151 (40)
175 BAR (2500 PSI)
140 BAR (2000 PSI)
70 BAR (1000 PSI)
35 BAR (500 PSI)

38 (10)
0

114 (30)
76 (20)
38 (10)
0

52,2 (70)

Torque Nm (lb.in)

135,6 (1200)

175 BAR
(2500 PSI)

113,0 (1000)
140 BAR
(2000 PSI)

90,4 (800)

44,7 (60)
37,3 (50)
29,8 (40)
22,4 (30)

67,8 (600)
45,2 (400)

70 BAR
(1000 PSI)

22,6 (200)

35 BAR
(500 PSI)

0
0

800

1600

2400

3200

14,9 (20)

Power kW (hp)

TORQUE

158,2 (1400)

7,5 (10)

0
4000

SPEED r/min

www.Go2Hydraulics.com

108

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
25M Motors
Performance Constants:
Oil SAE 10W,
viscosity 32 cSt (150 SUS)
@ 38C (100F)

65 LB. IN. MODEL


265 (70)
227 (60)
189 (50)

175 BAR (2500 PSI)


140 BAR (2000 PSI)
70 BAR (1000 PSI)
35 BAR (500 PSI)

303 (80)
265 (70)

151 (40)

227 (60)

114 (30)

189 (50)
175 BAR
(2500 PSI)
140 BAR
(2000 PSI)
70 BAR
(1000 PSI)
35 BAR
(500 PSI)

76 (20)
38 (10)
0

151 (40)
114 (30)
76 (20)
38 (10)
0

TORQUE

(1600)

175 BAR
52,2 (70)
(2500 PSI)

135,6 (1200)

140 BAR
(2000 PSI)

113,0 (1000)
90,4 (800)

70 BAR
(1000 PSI)

67,8 (600)

35 BAR
(500 PSI)

45,2 (400)
22,6 (200)

44,7 (60)
37,3 (50)
29,8 (40)
22,4 (30)
14,9 (20)

Power kW (hp)

Torque Nm (lb.in.)

158,2 (1400)

7,5 (10)

0
0

800

1600

2400

3200

0
4000

SPEED r/min

www.Go2Hydraulics.com

109

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

35M Motors
Performance Constants:
Oil SAE 10W,
viscosity 32 cSt (150 SUS)
@ 38C (100F)

80 LB. IN. MODEL


35 BAR (500 PSI)
70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

379 (100)
303 (80)
227 (60)

379 (100)

151 (40)

303 (80)

76 (20)

227 (60)
151 (40)

226,0 (2000)
180,8 (1600)
135,6 (1200)

TORQUE

74,6 (100)

175 BAR (2500 PSI)

59,7 (80)

140 BAR
(2000 PSI)
140 BAR (2000 PSI)

44,7 (60)
29,8 (40)

90,4 (800)
70 BAR
(1000 PSI)

45,2 (400)
0
0

76 (20)

800

1600
2400
SPEED r/min

35 BAR
(500 PSI)

3200

Power kW (hp)

Torque Nm (lb.in)

35 BAR (500 PSI)


70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

14,9 (20)
0
4000

95 LB. IN. MODEL


454 (120)

35 BAR (500 PSI)


70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

379 (100)
303 (80)

454 (120)

227 (60)

379 (100)

151 (40)

303 (80)

76 (20)

227 (60)
35 BAR (500 PSI)
70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

151 (40)
76 (20)
0

TORQUE

89,5 (120)

175 BAR (2500 PSI)

226,0 (2000)

74,6 (100)

140 BAR (2000 PSI)

180,8 (1600)

59,7 (80)
140 BAR
(2000 PSI)

135,6 (1200)
90,4 (800)

70 BAR
(1000 PSI)

35 BAR
(500 PSI)

45,2 (400)
0

800

1600

2400

3200

44,7 (60)
29,8 (40)
14,9 (20)

Power kW (hp)

Torque Nm (lb.in)

271,2 (2400)

0
4000

SPEED r/min

www.Go2Hydraulics.com

110

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
35M Motors
Performance Constants:
Oil SAE 10W,
viscosity 32 cSt (150 SUS)
@ 38C (100F)

115 LB. IN. MODEL


530 (140)

35 BAR (500 PSI)


70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

454 (120)
379 (100)

530 (140)

303 (80)

454 (120)

227 (60)

379 (100)

151 (40)

303 (80)
227 (60)

76 (20)
35 BAR (500 PSI)
70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

151 (40)
76 (20)
0

TORQUE

316,4 (2800)

104,4 (140)
89,5 (120)

271,2 (2400)

74,6 (100)

140 BAR (2000 PSI)

226,0 (2000)
180,8 (1600)

140 BAR (2000 PSI)

59,7 (80)
44,7 (60)

135,6 (1200)
70 BAR
(1000 PSI)

90,4 (800)

35 BAR
(500 PSI)

29,8 (40)

Power kW (hp)

Torque Nm (lb.in)

175 BAR (2500 PSI)

14,9 (20)

45,2 (400)

0
0

800

1600

2400

3200

4000

SPEED r/min

www.Go2Hydraulics.com

111

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

45M Motors
Performance Constants:
Oil SAE 10W,
viscosity 32 cSt (150 SUS)
@ 38C (100F)

130 LB. IN. MODEL


568 (150)

35 BAR (500 PSI)


70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

530 (140)

568 (150)

454 (120)

530 (140)

416 (110)

492 (130)

379 (100)

454 (120)

341 (90)

416 (110)

303 (80)

379 (100)

265 (70)

341 (90)

227 (60)

303 (80)
35 BAR (500 PSI)
70 BAR (1000 PSI)
140 BAR (2000 PSI) 265 (70)
175 BAR (2500 PSI)

492 (130)

189 (50)
151 (40)

227 (60)

114 (30)

189 (50)

76 (20)

151 (40)

38 (10)

114 (30)

76 (20)

119,3 (160)

38 (10)

Torque Nm (lb.in)

339,0 (3000)
271,2 (2400)
203,4 (1800)

Power kW (hp)

104,4 (140)
89,5 (120)

TORQUE

74,6 (100)

138 BAR
(2000 PSI)

59,7 (80)
69 BAR (1000 PSI)

44,7 (60)

135,6 (1200)

29,8 (40)

67,8 (600)

14,9 (20)

www.Go2Hydraulics.com

172 BAR (2500 PSI)

34 BAR (500 PSI)

800

1600
2400
SPEED RPM

3200

4000

112

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
45M Motors
Performance Constants:
Oil SAE 10W,
viscosity 32 cSt (150 SUS)
@ 38C (100F)
155 LB. IN. MODEL
681 (180)

35 BAR (500 PSI)


70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

644 (170)
606 (160)

681 (180)

568 (150)

644 (170)

530 (140)

606 (160)

492 (130)

568 (150)
530 (140)

416 (110)

492 (130)

379 (100)

454 (120)

341 (90)

416 (110)

303 (80)

379 (100)
35 BAR (500 PSI)
70 BAR (1000 PSI) 341 (90)
140 BAR (2000 PSI)
175 BAR (2500 PSI)
303 (80)

454 (120)

265 (70)
227 (60)
189 (50)

265 (70)

151 (40)

227 (60)

114 (30)

189 (50)

76 (20)

151 (40)

38 (10)

114 (30)

76 (20)

134,2 (180)

38 (10)

119,3 (160)
474,5 (4200)

104,4 (140)

406,7 (3600)

89,5 (120)

172 BAR (2500 PSI)

339,0 (3000)
271,2 (2400)
203,4 (1800)

Power kW (hp)

Torque Nm (lb.in)

TORQUE
138 BAR
(2000 PSI)

74,6 (100)
59,7 (80)

69 BAR
(1000 PSI)

44,7 (60)

135,6 (1200)

29,8 (40)

67,8 (600)

14,9 (20)

34 BAR
(500 PSI)

www.Go2Hydraulics.com

800

1600
2400
SPEED r/min

3200

4000

113

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

45M Motors
185 LB. IN. MODEL

Performance Constants:
Oil SAE 10W,
viscosity 32 cSt (150 SUS)
@ 38C (100F)

795 (210)

35 BAR (500 PSI)


70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

757 (200)
719 (190)

795 (210)

681 (180)

757 (200)

644 (170)

719 (190)

606 (160)

681 (180)

568 (150)

644 (170)

530 (140)

606 (160)

492 (130)

568 (150)

454 (120)

530 (140)

416 (110)

492 (130)
454 (120)

379 (100)
35 BAR (500 PSI)
70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

341 (90)
303 (80)

379 (100)

265 (70)

341 (90)

227 (60)

303 (80)

189 (50)

265 (70)

151 (40)

227 (60)

114 (30)

189 (50)

76 (20)

151 (40)

38 (10)

114 (30)

76 (20)

164,0 (220)

38 (10)

149,1 (200)

134,2 (180)
119,3 (160)

Torque Nm (lb.in)

474,5 (4200)
406,7 (3600)
339,0 (3000)

Power kW (hp)

542,3 (4800)

172 BAR (2500 PSI)


TORQUE

104,4 (140)

138 BAR
(2000 PSI)

89,5 (120)
74,6 (100)

271,2 (2400)

59,7 (80)

203,4 (1800)

44,7 (60)

135,6 (1200)

29,8 (40)

67,8 (600)

14,9 (20)

416 (110)

0
0

69 BAR
(1000 PSI)
34 BAR (500 PSI)

800

1600

2400

3200

4000

SPEED r/min

www.Go2Hydraulics.com

114

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Typical Performance
50M Motors
220 LB. IN. MODEL

Performance Constants:
Oil SAE 10W,
viscosity 32 cSt (150 SUS)
@ 38C (100F)

833 (220)
35 BAR (500 PSI)
70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

757 (200)
681 (180)

833 (220)

606 (160)

757 (200)

530 (140)

681 (180)

454 (120)

606 (160)

379 (100)

530 (140)

303 (80)

454 (120)

227 (60)

35 BAR (500 PSI)


70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

151 (40)

255 LB. IN. MODEL

379 (100)
303 (80)

76 (20)

227 (60)

151 (40)
76 (20)

35 BAR (500 PSI)


70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

757 (200)

909 (240)

681 (180)

833 (220)

606 (160)

757 (200)

530 (140)

681 (180)

454 (120)

606 (160)

379 (100)

530 (140)

303 (80)

454 (120)
35 BAR (500 PSI)
70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

227 (60)
151 (40)

677,9 (6000)

Torque Nm (lb.in)

833 (220)

179,0 (240)

TORQUE

564,9 (5000)

149,1 (200)

172 BAR (2500 PSI)

119,3 (160)
140 BAR
(2000 PSI)
70 BAR 89,5 (120)
(1000 PSI)

451,9 (4000)
339,0 (3000)
226,0 (2000)

35 BAR
(500 PSI)

29,8 (40)

113,0 (1000)
0

59,7 (80)

Power kW (hp)

909 (240)

0
0

800

1600

2400

3200

SPEED r/min
379 (100)
303 (80)

76 (20)

227 (60)

151 (40)
76 (20)

677,9 (6000)

Torque Nm (lb.in)

TORQUE

179,0 (240)

172 BAR (2500 PSI)

564,9 (5000)

149,1 (200)

451,9 (4000)

140 BAR
(2000 PSI) 119,3 (160)
70 BAR
89,5 (120)
(1000 PSI)

339,0 (3000)
226,0 (2000)

59,7 (80)
35 BAR
(500 PSI)
29,8 (40)

113,0 (1000)
0
0

800

www.Go2Hydraulics.com

1600
SPEED r/min

2400

3200

Power kW (hp)

790,9 (7000)

115

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

50M Motors
Performance Constants:
Oil SAE 10W,
viscosity 32 cSt (150 SUS)
@ 38C (100F)
300 LB. IN. MODEL
1060 (280)

35 BAR (500 PSI)


70 BAR (1000 PSI)
140 BAR (2000 PSI)
175 BAR (2500 PSI)

984 (260)
909 (240)

1060 (280)

833 (220)

984 (260)

757 (200)

909 (240)

681 (180)

833 (220)

606 (160)

757 (200)

530 (140)

681 (180)

454 (120)

606 (160)

379 (100)

530 (140)

303 (80)

454 (120)
35 BAR (500 PSI)
70 BAR (1000 PSI)
140 BAR (2000 PSI) 379 (100)
175 BAR (2500 PSI)

227 (60)
151 (40)

303 (80)

76 (20)

227 (60)

151 (40)
76 (20)

790,9 (7000)

Torque Nm (lb.in)

TORQUE

208,8 (280)

172 BAR (2500 PSI)

677,9 (6000)

179,0 (240)

564,9 (5000)

149,1 (200)
140 BAR
(2000 PSI)
119,3 (160)
70 BAR
(1000 PSI)

451,9 (4000)

89,5 (120)

339,0 (3000)
35 BAR
(500 PSI)

226,0 (2000)

59,7 (80)
29,8 (40)

113,0 (1000)
0

Power kW (hp)

903,9 (8000)

800

1600

2400

3200

SPEED r/min

www.Go2Hydraulics.com

116

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Foot Mounts
Foot bracket kits can be used to mount
pumps or motors having standard SAE-J
744 2-bolt A, B, or C mounting flanges.
These designations correspond to -A-,

-B-, and -C- letters in the kit model


number. Each kit includes a bracket and
screws for mounting to the pump or

motor. Kits are not included with pumps


and motors and must be ordered
separately by model number.

R UNC-2B THREAD
(4 PLACES)
J

BOLT CIRCLE

0,05 (002)

4HOLES
FOR MOUNTING
H

E
K

D
C

Model
number

Dimensions mm (in.)
D
E

FBA10

134,9
(5.31)

69,9
(2.75)

152,4
(6.00)

76,2
(3.00)

FBB10

180,8
(7.12)

92,2
(3.63)

171,5
(6.75)

FBC10

215,9
(8.50)

109,5
(4.31)

265,2
(10.44)

Model
number

127,0
(5.00)

36,6
(1.44)

63,5
(2.50)

12,7
(.50)

85,8
(3.38)

146,0
(5.75)

36,6
(1.44)

73,2
(2.88)

12,7
(.50)

132,6
(5.22)

235,0
(9.25)

50,8
(2.00)

117,6
(4.63)

15,7
(.62)

Dimensions mm (in.)
M
N
P

FBA10

106,4
(4.19)

96,0
(3.78)

15,0
(.59)

50,8
(2.00)

12,7
(.50)

82,6
(3.25)

17,5
(.69)

.38-16

11,2
(.44)

FBB10

146,0
(5.75)

95,8
(3.77)

15,0
(.59)

50,8
(2.00)

12,7
(.50)

101,6
(4.00)

17,3
(.68)

.50-13

17,3
(.68)

FBC10

181,1
(7.13)

131,6
(5.18)

19,1
(.75)

76,2
(3.00)

17,3
(.68)

127,0
(5.00)

19,1
(.75)

.62-11

17,3
(.68)

www.Go2Hydraulics.com

117

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Filler/Breather Unit

SP-113-C
Dimensions in millimeters (inches)
General Usage:
As a filler cap and air filter for hydraulic
reservoirs.
Provides protected air vent opening, dirt
screen and air filter.
Cover attached to neck of filter by
means of a safety chain. Prevents cap
being lost or misplaced.
Pressure Drop VS. Oil Flow
Into/Out of Reservoir
Pressure Drop (Inches Hg)
L/min
(USgpm)
57 (15)
76 (20)
91 (24)
102 (27)

.25
.50
.75
1.00

10 MICROMETRE (NOMINAL)
AIR FILTER ELEMENT INSIDE CAP
5,5 (.218) 6 HOLES
(EQUALLY SPACED)

(6) 10-30 SELF TAPPING


SCREWS FURNISHED
117,6
(4.63)
12,7
(.500)

76,2
(3.00)

82,5

(3.25)
47,8

(1.88)
65,0

(2.56)

73,2

(2.88)
GASKET

www.Go2Hydraulics.com

30 MESH GALVANIZED
STEEL WIRE SCREEN

118

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

SAE 4-bolt Solid Flanges

Threaded Connection
Dimensions in millimeters (inches)
C SCREW THD.

E
D

J DIA.

SURFACE MUST BE
FLAT AND SMOOTH

H
B

A SAE
STRAIGHT THD.

Model

Assembly

A
SAE Straight
Thread

FL1-6-12S-10

683829

1.0625-12
(3/4 tube)

52,3
(2.06)

3/8-16

65,0
(2.56)

23,9
(.94)

47,8
(1.88)

11,2
(.44)

22,4
(.88)

19,0
(.75)

13,5
(.53)

31,8
(1.25)

FL1-8-16S-10

683830

1.3125-12
(1 tube)

58,7
(2.31)

3/8-16

69,8
26,2
52,4
(2.75) (1.03) (2.06)

13,1
(.52)

26,2
25,4
(1.03) (1.00)

16,8
(.66)

35.0
(1.38)

FL1-10-20S-10

683831

1.625-12
(1-1/4 tube)

73,1
79,2
29,4
58,7
7/16-14
(2.88)
(3.12) (1.16) (2.31)

15,1
(.59)

30,2
31,8
(1.19) (1.25)

21,3
(.84)

38,1
(1.50)

FL1-12-24S-10

683832

1.875-12
(1-1/2 tube)

82,6
(3.25)

17,8
(.70)

35,7
38,1
(1.41) (1.50)

18,5
(.73)

41,1
(1.62)

www.Go2Hydraulics.com

1/2-13

93,7
35,0
69,8
(3.69) (1.38) (2.75)

119

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Oil Recommendations
The oil in a hydraulic system serves as
the power transmission medium. It is
also the systems lubricant and coolant.
Selection of the proper oil is a
requirement for satisfactory system
performance and life.
The following recommendations will
assist in the selection of suitable oils for
use with Vickers products. Vickers does
not publish a recommended oil list by
brand name or supplier due to the
extremely wide variety of oil types on the
market.
In most cases, use of these
recommendations will lead to selection
of a suitable oil. However, due to the
complex nature of oil formulation, the
variety of oils available and peculiarities
of individual hydraulic applications, there
will be rare instances where oil selected
on the basis of these recommendations
will yield unsatisfactory results. Vickers
cannot be responsible for such
exceptions. In this respect, the customer
is encouraged to consult his Vickers
representative when selecting an oil.

Important Factors In Selecting


An Oil
Additives
Hydraulic fluids contain a number of
additive agents which materially improve
various characteristics of oil for hydraulic
systems. These additives are selected
to reduce wear, increase chemical
stability, inhibit corrosion and depress
the pour point.
Pump performance and reliability are
directly affected by the antiwear additive
formulation contained in the oil. Oils
providing a high level of antiwear
protection are recommended for
optimum performance and long life.
Viscosity
Viscosity is the measure of fluidity. The
oil selected must have proper viscosity
to maintain an adequate lubricating film
at system operating temperature.
In addition to dynamic lubricating
properties, oil must have sufficient body
to provide an adequate sealing effect
between working parts of pumps,
valves, cylinders and motors, but not
enough to cause pump cavitation or
sluggish valve action.

www.Go2Hydraulics.com

Optimum operating viscosity of the oil


should be between 16 cSt (80 SUS) and
40 cSt (180 SUS).
Viscosity index reflects the way
viscosity changes with temperature; the
smaller the viscosity change, the higher
the viscosity index. The viscosity index
of hydraulic system oil should not be
less than 90. Multiple viscosity oils, such
as SAE 10W30, incorporate additives to
improve viscosity index (polymer
thickened). Oils of this type generally
exhibit both a temporary and permanent
decrease in viscosity due to oil shear
encountered in the operating hydraulic
system. The actual viscosity can,
therefore, be far less in the operating
hydraulic system than what is shown in
normal oil data. Accordingly, when such
oils are selected, it is necessary to use
those with high shear stability to ensure
that viscosity remains within
recommended limits while in service.
Chemical Stability
Oxidative and thermal stability are
essential characteristics of oils for
Mobile hydraulic systems. The
combination of base stocks and
additives should be stable during the
expected lifetime of the oil when
exposed to the environment of these
systems.

Suitable Types Of Oil

Certain Other Types Of


Petroleum Oil
Other oils are suitable if they meet the
following provisions:
1. Contain the type and content of
antiwear additives found in the above
designated crankcase oils, and have
passed the pump tests as given in
M-2952-S.
2. Have sufficient chemical stability for
Mobile Hydraulic system service.
3. Meet the viscosity recommendations
shown in the following tables.

Oil Viscosity Recommendations


Crankcase Oils
Hydraulic System
Operating Temp.
Range*

SAE Viscosity
Designation

23C to 54C
(10F to 130F)

5W, 5W-20,
5W-30

18C to 83C
(0F to 180F)

10W

18C to 99C
(0F to 210F)

10W-30, 10W-40

10C to 99C
(14F to 210F)

20-20W

Antiwear Hydraulic Oils


Hydraulic System
Operating Temp.
Range*

ISO Viscosity
Grade

Crankcase oil having letter designation


SC, SD, SE or SF per SAE J183 FEB80.
Note that one oil may meet one or more
of these designations.

21C to 60C
(5F to 140F)

22

15C to 77C
(5F to 170F)

32

Antiwear Hydraulic Oil

9C to 88C
(15F to 190F)

46

1C to 99C
(30F to 210F)

68

Crankcase Oil

These are produced by all major oil


suppliers and should consist of good
quality base stocks compounded with
antiwear, anti-oxidation, and antirust
additives.
Due to the large number of different
antiwear hydraulic oils, it is impossible
for Vickers to test its products with all of
them and recommend those that are
suitable. Because of this, an evaluation
procedure was developed for fluid
suppliers to establish the suitability of
their products for use in Vickers
components. Publication M-2952-S,
Pump Test Procedure for Evaluation of
Antiwear Hydraulic Fluids for Mobile
Systems, which gives the details of this
test procedure, is available on request.

* Temperatures shown are cold


(ambient) start-up to maximum
operating. During cold start-up, avoid
high-speed operation of hydraulic
components until the system is warmed
up to provide adequate lubrication.

120

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Oil Recommendations and Hydraulic Formulae


Arctic Conditions
Arctic conditions represent a specialized
field where extensive use is made of
heating equipment before starting. If
necessary, this and judicious use of the
following recommendations should be
used:
1. SAE 5W or 5W-20 oil.
2. Oils specially developed for use in
arctic conditions, such as synthetic
hydrocarbons, esters, or mixtures of
the two. Skydrol must not be used.
Operating temperature should be closely
monitored to avoid exceeding a
temperature of 54C (130F) with any
lightweight oil.

Special Requirements
When special considerations indicate a
need to depart from recommended oils
or operating conditions, consult your
Vickers representative.

Horsepower:
Horsepower =

GPM x PSI
1714

Torque:
Torque (lb. in.) =

CU. IN./REV. x PSI


2p

Torque (lb. in.) =

HP x 63025
RPM

Volumetric Efficiency:
Volumetric efficiency (pump) =

OUTPUT GPM
X 100
THEORETICAL GPM

Volumetric efficiency (motor) =

THEORETICAL GPM
X 100
INPUT GPM

Overall Efficiency:
Overall efficiency =

OUTPUT HP

X 100

INPUT HP

Flow:
Flow (gpm) =

CU. IN./REV. x RPM


231

Conversion Factors:
1 hp = 33,000 ft. lbs. per minute
1 hp = 42.4 btu per minute
1 hp = 0.746 kWhr (kilowatt hour)
1 U.S. gallon = 231 cubic inches
Pipe volume varies as the square of the
diameter; volume in gallons = 0.0034 D2L
where: D = inside diameter of pipe in inches
L = length in inches
Velocity in feet per second = 0.408 x flow (gpm)
D2
where: D = inside diameter of pipe in inches.
Atmospheric pressure at sea level = 14.7 psi.
Atmospheric pressure decreases approximately 0.41 psi
for each 1,000 feet of elevation to o 23,000 feet.
Pressure (psi) = feet head x 0.433 x specific gravity.
Specific gravity of oil is approximately 0.85.
Thermal expansion of oil is about 1 cu. in. per 1 gallon per
10F rise in temperature.

www.Go2Hydraulics.com

121

1800-232-0646 (Intl.) +1-206-319-9433

www.Go2Hydraulics.com

1800-232-0646 (Intl.) +1-206-319-9433

Flow Capacities of Piping

100
20000

90
80
BASED ON FORMULA
70
AREA (SQ. IN.) =

GPM. X 0.3208
VELOCITY (FT./SEC.)

60
50
10000
9000

40

8000
7000

4 1/2

30

4 1/2
4

20
15

6000
3 1/2

3 1/2

5000
3

20
4000

2 1/2

2 1/2

10
9
8
7
6
5
4

15
2

3000

1 3/4
1 1/2
1 1/2

10

2
2

1 1/4
2000

1 1/4

8
1

7
6

3/4

1000

1/2
4

5/8

.4

MAXIMUM
RECOMMENDED VELOCITY
FOR
INTAKE LINES

.3

9/16

800
700

.5
3/4

900

7/8

1
.9
.8
.7
.6

3/8

1/2

.2
6

7/16

600

3/8

1/4
500

5/16
2
1/8

400

1/4

.1
.09
.08
.07
.06

8
9
10

.05
.04
.03

www.Go2Hydraulics.com

.01
.009
.008
.007
.006
.005
.004

MAXIMUM
RECOMMENDED VELOCITY
FOR
PRESSURE LINES

20

30

40

50

VELOCITY FEET PER SECOND

.4

1/8

PIPE, TUBE AND


HOSE INCHES

.5
100

ACTUAL INSIDE DIAMETER OF

.75

NOMINAL STANDARD PIPE SIZE

200

15
AREA OF PIPE, TUBE AND HOSE SQ. IN.

.02
1
FLOW GALLONS PER MINUTE

FLOW CUBIC INCHES PER MINUTE

300

122

1800-232-0646 (Intl.) +1-206-319-9433