Sie sind auf Seite 1von 3

Crux Prestressing Pvt. Ltd.

Job : Mr. Gopala Rao, Multi Storey Bldg Pile Foundation for Column Type C1
Prepared by Checked by Date Venkat KSR Aug-13 Note No: 001 Revision: R0

4.0 1} 2} 3} 4} 5) 5.0

Pile Cap Data : Concrete grade = M 25 Steel Grade used = Fe 500 Clear cover to the pile cap 50 mm plan area of pile cap = 8.15 m x 8.15 m Depth of Pile Cap = 1.5 m Calculation of Depth of Pile cap Lever Arm: Dist upto the face of pier Lever Arm for general case Longitudinal Direction c/c distance between pier and pile c/c distance between pier and pile c/c distance between pier and pile c/c distance between pier and pile = c/c distance betwn pier and pile - half the pier width 3.75 0.75 /2 = = 3.375 m Lever Arm (e) e1 = e2 = e3 = e4 =

(P1) (P2) (P3) (P4)

= = = =

3.75 3.75 1.25 1.25

m m m m

3.38 3.38 0.88 0.88

m m m m

Bending Moment M = P1xe1+P2xe2+P3xe3+P4xe4 Factored Pile Forces Pile P1 V (t) (+/+) 622 V (t) (+/-) 622 V (t) (+/+) 622 622 V (t) (+/+)

P2 622 622 622 622

P3 622 622 622 622

P4 622 622 622 622

Moment In Pile Cap from Load Calculation Bending Moment Case B.M.(kN-m) 1.5(DL+SDL+LL) 10576.94 10574.04 10571.84 10568.94 10576.94 Max.

Depth Required

= 0.136 = 617.8

M fck mm <

b 1500 mm OK

D d

= =

1500 1500

mm - 50 - 25 /2

= 1437.5 mm

Crux Prestressing Pvt. Ltd.


Job : Mr. Gopala Rao, Multi Storey Bldg Pile Foundation for Column Type C1
Prepared by Checked by Date Venkat KSR Aug-13 Note No: 001 Revision: R0

Ast required

0.5 x fck fy

1-

4.6 x fck 1 -

x b x d

x b x d
6 2

Ast required

0.5 x 25 1500 = 17442 mm2


1438 =

4.6 x 10576.9 x 10 25 x 8150 x 1438

x 8150 x 1438

Min. Steel = :. Provide

0.17 x 8150 x 100 20 @ 125

2 19916.6 mm

20483

OK

6.0

Check for Punching Shear in Pile Cap Max reaction from Column = 9951 kN (Factored) Width/ Depth of Column = 0.90 m Effective depth of pile cap = 1.438 m Section for punching shear at a distance d/2 = 0.719 from the face of the pier Perimeter of critical section = 6.175 m Punching shear stress= 6.175 9951 x 1.44 = 1.12 OK N/mm2

kN/m2 = 1121 Permissible shear stress = 0.25 sqrt(fck) 2 = 1.25 N/mm > 1.12

Max reaction from pile = 622.3 kN Diameter of Pile = 0.5 Perimeter = 0.399 m Effective depth of pile cap = 1.438 m Section for punching shear at a distance d/2 = 0.719 from the face of the pile Perimeter of critical section = 5.930 m Punching shear stress= 622 5.930 x 1.44 2 2 = 73.0 kN/m = 0.073 N/mm Permissible shear stress = 0.25 sqrt(fck) = 1.25 N/mm2 > 0.07 OK

Crux Prestressing Pvt. Ltd.


Job : Mr. Gopala Rao, Multi Storey Bldg Pile Foundation for Column Type C1
Prepared by Checked by Date Venkat KSR Aug-13 Note No: 001 Revision: R0

7.0

Check for one-way Shear in Pile Cap One Way shear on Pile Foundations shall be checked at d from Pier face = 1438 mm

Shear force due to Piles (P1, P2, P3 & P4) =

2488.7

kN

Effective Depth of the Pile cap, d Width at the section, b Shear Stress

= 1438 mm = 8150 mm = 2488746 8150 x 1438 = 0.21 N/mm2 <


2 3.70 N/mm

uc max = 3.7 N/mm2 Percentage of steel provided at support, Pt = 0.17 Maximum allowable shear stress, = 16.6 N/mm Permissible shear stress in concrete, uc
2

2 = 0.312 N/mm >

2 0.21 N/mm

OK