Sie sind auf Seite 1von 17

0EE.138.

185-2
008

Technical Document of Jiamusi Electric Machine Co., Ltd.


0EE.138.185 -2008

YKK Series of High-Voltage Three-phase


Induction Motors
Products Catalog
(Frame size355630)

Promulgated on March 1,2009

Effective as of March 1,2009

Issued by Jiamusi Electric Machine Co., Ltd.

0EE.138.185-2008

YKK Series of High-Voltage Three-phase Induction Motor


Products Catalog
1General
YKK series of high-voltage three-phase induction motors are optimized serial products, which
are designed and manufactured by our company by adopting advanced techniques at home and abroad
and being in combination with practical experience on high-voltage induction motors having been
produced for recent years. This series of motors have advantages of light weight, high efficiency,
energy saving, low noise, small vibration, high reliability, fine cooling effect, long service life,
convenient installation and maintenance, etc.
This series of motors are applicable to universal mechanical equipment or other similar
mechanical equipment, such as: blower fan, water pump, compressor, cracker, trimming machine tool,
transport machinery, etc, which are used in petroleum, chemical industry, coal, power plant,
metallurgy, traffic, weaving, medicine, grain processing, etc..

2 Construction features
The motors are of box-section construction, and the frame is welded into box-section by steel
plate, so the weight of motor is light and rigidity is good. The air to air cooler is located at
the top of the motor.
The motor has a laminated core which is first compressed and secured before it is fitted into
the frame and then pressen into the machined frame. The stator windings are class F insulated,
reliable anticorona measures can be adopted for 10KV motors, the ends of windings are bonded and
fixed firmly, and the winding are vacuum pressure impregnated with solventless varnish. Therefore,
therefore, the motors have good and reliable insulating performance, higher mechanical strength,
higher moisture-resistance and longer service life.
The motor is of cast aluminium rotor construction, and is manufactured by reliable cast aluminium
technics. As the rotor is dynamically balanced, so the motor can run smmothly.
The bearing has two types of rolling bearing and sleeve bearing, it is confirmed by the motor
power and speed. The degree of protection are IP44, IP54 or IP55, the rolling contact bearings are
provided filling- and draining-oil devices without stopping of motor.
The main terminal box is on the right side of motor (viewed from DE), and can also on the left
side according to the users requirement. Inside and outside of the terminal box are provided with
separated earth terminals.
According to the users requirements, we can provide temperature detector device on important
part, such as stator winding, bearing, for site observing and remote monitoring to ensure the motor
operate on the safe side

3 Reference standards
GB 755 Rotating electrical machinesRating and performance
GB/T 997 Construction and Mounting Arrangement Sysmbol of Motor
GB/T 1993 Rotating Electrical Machine-- Method of Cooling
GB/T 4772.2 Dimensions and Outputs of Rotating Electric Machine--Part 2: Frame Sizes 355 to
1000 and Flange No. 1180 to 2360
GB/T 4942.1 Classification of Degrees of Protection ( IP code) Provided by Enclosure of
Rotating Electrical Machines
GB 10068 Mechanical vibration of rotating electrical machines with shaft heights of 56mm and
larger-Measurement, evaluation and limits of vibrations
GB/T 10069.1 Rotating electrical machines--Measurement method and limitsPart 1: Engineering
method for determining noise
GB/T 10069.3 Measurement Method and Limits of Noise of Rotating Electric MachinePart 3:
1

0EE.138.185-2008
Limits of Noise

4 Guide for type-choosing


4.1 Meaning of the type of motors
For example
Y
KK
500
1 - 2
No. of poles2-pole
Core length
Shaft height 500mm
Cooling construction(KK represents air-to-air cooling

Induction motor

4.2 Series type spectrum see the following table 1(6kV) and table 2(10kV)
Table 1 Type spectrum forYKK series motor (6kV)
Synchronous speed
r/min
Frame
3000
1500
1000
750
600
500
sises
Power kW
185
220
1
200
250
2
----220
280
355 3
250
315
4
-185
--1
-200
280
355
2
-220
315
400
400 3
--185
250
355
450
4
200
280
400
500
5
220
315
450
-6
-185
----1
-200
250
355
500
560
2
-220
280
400
560
630
450 3
185
250
315
450
630
710
4
200
280
355
500
710
800
5
220
315
400
560
800
900
1
250
355
450
630
900
1000
500 2
280
400
500
710
1000
1120
3
315
450
560
800
1120
1250
4
355
500
630
900
1250
1400
1
400
560
710
1000
1400
1600
2
450
630
800
1120
1600
1800
560 3
500
710
----4
560
800
900
1250
1800
2000
1
630
900
1000
1400
2000
2240
630 2
710
1000
1120
1600
2240
2500
3
800
1120
1250
---4

0EE.138.185-2008

Table2 Type spectrum for YKK series motor (10kV)


Frame
sizes

Synchronous speed r/min


1000
750
600
Power kW

3000

1500

1
2
3
4
5

220
250
280
315
355

220
250
280
315
355

--

1
2
450 3
4
5
6
1
2
500 3
4
5
1
2
560 3
4
5
1
2
630 3
4
5

400
450
500
560
--630
710
800
900
1000
1120
1250
1400

1600
1800
2000

400
450
500
560
--630
710
800
900
1000
1120
1250
1400

1600
1800
2000

220
250
280
315
355
400
450
500
560
630
710
800
900
1000
1120

1250
1400
1600

400

--

--

--

--

315
355
400
450
500
560
630
710
800

900
1000
1120

220
250
280
315
355
400
450
500
560
630
710
800
900
1000

500

--

---220
250
280
315
355
400
450
500
560
630
710

4.3 Voltage and frequency


There are two kinds of rated voltage 6 kV and 10kV, rated frequency is 50Hz.
4.4 Insulation class and temperature rise limits
The motors are class F insulated.
4.5 Bearing construction and temperature limits
The motors are provided with rolling contact bearings and sleeve bearings and type of bearing
can be decided according to the data of overall and mounting dimensions. Normal products for sleeve
bearing is forced-lubricated bearing, and self- lubricated bearing can also be manufactured on user
request.
4.6 Degree of protection
Degree of protection for motor is IP54, IP55 can also be manufactured.
4.7 Cooling methods
Cooling methods is IC611W or IC616.
4.8 Weather-protected type and operation environment conditions
Damp and tropical climate type, indoor (TH); outdoor (THW);
Dry and tropical climate type, indoor (TA); outdoor (TAW);
Tropical l climate type, indoor (T); outdoor (TW)
Outdoor light corrosion-proof type (W)
Outdoor middle corrosion-proof type (WF1)
Outdoor strong corrosion-proof type (WF2)
Indoor middle corrosion-proof type (F1)
Indoor strong corrosion-proof type (F2)
3

0EE.138.185-2008
The protection type that the above mentioned is marked following the motor type, eg: YKK500-2WF1
4.9 Connection
Y-connection
4.10 Cable entry device
Rubber sheath device will be normally provided; steel conduit and armor cable device can also
be provided on user request.
4.11 Duty
S1 continuous running duty
4.12 Performance index tolerance
Efficiency101
Power factor cos1cos/6
The min. absolute value is 0.02
The max. absolute value is 0.07
Locked rotor current : 20 of current guarantee value
Locked rotor torque: 15 of torque guarantee value
Pull-up torque: 15 of torque guarantee value
Breakdown torque: 10torque guarantee value

5 Operation conditions of motor in site


5.1 Altitude above sea level is up to 1000m.
5.2 Ambient air temperature doesnt exceed 40.
5.3 The lowest ambient air temperature should not be less than -15, The lowest ambient air
temperature for the motors with sleeve bearing or air-to-water cooler, should not be less than 0
.
5.4 For the motors with air-to-water cooler: temperature of cooling water at inlet of cooler
should be 525
5.5 Tolerance for voltage and frequency
a) The motor can continually operate at voltage deviation is 5of rated value, frequency
deviation is 2% of rated value and reach its basic performance, but the performance have some
difference compared with that at rated voltage and frequency, the temperature rise of motor can
be higher than that at rated voltage and frequency.
b) The motor can operate at voltage deviation is 10% of rated value, frequency deviation is
5%+3% of rated value and reach its basic performance, but the performance have some difference
compared with that at rated voltage and frequency, the temperature rise of motor can be higher than
that at rated voltage and frequency.
c) The other electric operation condition of motor should be in accordance with GB755.

6 Starting requirements
6.1 When the driven machineries are water pumps or fans, starting should be the following
conditions:
6.2 User network should guarantee that terminal voltage of motor should not less than 85% of
rated voltage during motor starting
6.3 The inertia movement for rotational part of driven machineries (converted to motor speed)
should be less than the values which is calculated from the following formula.

P 0.95

1.5
0.0045 P

J f = 1.34
(n
(n
) 2.4
)1.8
1000
1000
Where: JfLoad movement of inertia kgm2
PRated power of motor kW
NRated speed of motor r/min
On above condition, it is permitted that the motor can continuously be started twice at actual
cold state, or the motor can be started once at hot state, between two starts, it should be naturally
stopped, and the next start should be done at least one hour after shutdown.
4

0EE.138.185-2008

7 load connection
The motor normally flexible connected with driven load

8 Measurement and protection


8.1 For the temperature detector which is chosen by user, such as bearing detectorstator
temperature detector, temperature detector is platinum resistance Pt100, all output signal is
resistance signal.
8.2 Whether the anti-condensation heater shall be provided is choose by user on the basis of
operating site.

9 Ordering information
9.1 Select the factor which should be taken into account for three-phase induction motor.
a) Operating environment: ambient temperature, altitude,etc.
b) Mechanical characteristic and moment of inertia of the driven equipment.
c) Starting method,starting frequeccy and starting voltage drop.
d) Temperature rise check
e) Direction of rotation
f)The mechenical connection method and requirement for motor to the driven load.
g)Position of terminal box
h)Duty type and other special requirement.
9.2 Normal ordering
The order without special requirement is normal order, which should be note the following
motors parameter(demonstration):
a)TypeYKK 5001-2
b)Rated power900kW
c)Rated voltage6kV
d)Rated frequency: 50Hz
e)No. of poles2
f)Mounting arrangement: B3
g)Duty type: S1
h)Method of cooling: IC611
i)Degree of protection: IP54
j)Direction of rotation: CW.
k)Operating environment: Indoor
l)Method of incoming line: Rubber cable
m)Altitude above sea level1000m
n)Ambient temperature15+40
9.3 Order with additional requirment
If theres requirement for one or more items of the following, it must be stated when ordering.
a)Votages are not 6kV and 10kVeg.:3.3kV6.3kV11kV
b)Frequency is 60Hz
c)The power is not the standard value according to the data sheet; or the corresponding relations
between power and mounting dimension are different from the data sheet.
d) The altitude is above 1000m
e) Ambient temperature: above +40, or the lowest temperature is lower than -20.
f) Low noise: the noise is lower than the specification of GB 10069.3.
g) Non-standard mounting dimension: the corresponding relations between frame size and mounting
dimension are different from the data sheet.
h)The special environment to be stated: such as humid tropics, outdoor, corrosion, salt mist,
mold, dust, blown sand, etc.. For the corrosion, the corrosive materials should be listed so that
the corresponding measures can be taken according to the degree of corrosion and property when
design.
i)The special requirements for electrical performance: eg: high lockedrotor torque, high slip,
high moment of inertia and low locked-rotor current, etc..
5

0EE.138.185-2008
j)Other special requirements: eg: protective relay device (temperature detector device of
winding and bearing, differential protection), special bearing, special packaging, and the spare
parts without the stipulation, etc..
k)If you have these special requirements above mentioned and other requirements, please consult
with the technical department or sign technical agreement with our company.
l)With technical development of products and revisal of relevant standards at home and aborad,
technical data shown herein are subject to change without notice. Please ask for the formal outline
and mounting dimension drawings.
10 Technical data (guranteed value
10.1YKK series of high-voltage three-phase induction motors 6kV

0EE.138.185-2008

Table 3

Type

Rated power
(kW)

Technical data of YKK series (6KV) motors (guaranteed value)


Rated

Rated

current

speed

(A)

(r/min)

Efficiency
(%)

YKK3551-2

220

26.9

92.5

YKK3552-2

250

30.6

92.6

YKK3553-2

280

34.2

92.8

YKK3554-2

315

38.3

93.1

YKK4001-2

355

42.5

93.4

YKK4002-2

400

47.8

93.7

YKK4003-2

450

53.6

YKK4004-2

500

YKK4501-2

Power

Breakdown

Locked-

Locked rotor

factor cos

torque

rotor torque

current

rated torque rated torque rated current

Moment of inertia
Weight
Motor

Jm

(kg.m2)

Load

kg

J (kg.m2)

2.7

22.0

2345

3.0

24.0

2430

3.4

26.0

2550

3.6

27.0

2665

5.3

30.0

2523

5.7

32.0

2623

94.0

6.5

34.0

2673

59.4

94.2

6.8

35.0

2819

560

66.4

94.4

9.4

40.0

3765

YKK4502-2

630

74

94.6

10.8

44.0

3900

YKK4503-2

710

83

94.7

11.8

46.0

4045

12.4

48.0

4210

YKK4504-2

800

93.3

2985

0.85

0.86

0.86

94.8

YKK5001-2

900

104.8

95.0

YKK5002-2

1000

116.3

95.1

YKK5003-2

1120

130.1

95.2

YKK5004-2

1250

145.1

YKK5601-2

1400

YKK5602-2

7.0

0.87

17.2

73.4

4745

19.1

85.0

4945

21.1

93.0

5145

95.3

23.0

101.0

5345

160.5

95.4

39.8

106.0

6220

1600

183.1

95.5

42.4

107.0

6320

YKK5603-2

1800

205.9

95.6

46.4

108.0

6580

YKK6301-2

2000

228.5

95.7

47.4

110.0

8700

0.6

0.88
1.8

YKK6302-2

2240

255.7

95.8

51.7

114.0

9100

YKK6303-2

2500

285.1

95.9

57.1

120.0

9500

185

22.6

92.8

3.0

68.0

2260

YKK3552-4

200

24.4

92..9

3.4

78.0

2350

YKK3553-4

220

26.8

93.0

3.8

88.0

2420

YKK3554-4

250

30.4

93.1

4.2

97.0

2500

YKK4001-4

280

33.6

93.2

5.8

108

2453

YKK4002-4

315

37.8

93.3

6.0

120

2573

YKK4003-4

355

42.5

93.5

6.2

133

2643

YKK4004-4

400

47.8

93.7

6.5

147

2763

YKK4005-4

450

53.6

7.0

161

2823

YKK4501-4

500

59.5

10.0

178

3980

YKK4502-4

560

66.5

94.2

11.0

197

4090

YKK4503-4

630

74.7

94.4

12.0

218

4200

YKK4504-4

710

84.0

94.6

13.0

241

4290

YKK5001-4

800

93.3

94.8

22.0

266

4710

YKK5002-4

900

104.9

94.9

24.0

290

4960

YKK5003-4

1000

116.4

95.0

26.0

318

5145

YKK5004-4

1120

130.3

95.1

30.0

347

5355

YKK5601-4

1250

143.6

95.2

51.0

379

7220

YKK3551-4

1485

93.9

0.85

0.86

0.7

94.0

0.87

0.88

0.6

6.5

0EE.138.185-2008
Table 3(continuous)
Rated

Technical data of YKK series (6KV) motors (guaranteed value)


Locked

Moment of inertia

Rated

power current

speed

(kW)

(A)

(r/min)

YKK5602-4

1400

160.6

95.3

57.0

470

7470

YKK5603-4

1600

183.4

95.4

60.0

460

7720

YKK6301-4

1800

206.1

96.0

498

9650

YKK6302-4

2000

228.8

95.6

102.0

540

10050

YKK6303-4

2240

255.9

95.7

112.0

584

10450

YKK4001-6

185

23.5

92.4

8.0

193

2343

YKK4002-6

200

25.3

92.6

8.7

210

2393

Type

1485

Efficiency

(%)

95.5

Power

Breakdown

Rated

factor
cos

torque
rated
torque

0.88

Lockedrotor torque
rated torque

rotor
current
rated current

0.6

6.5

0.82

Motor

Jm

(kg.m2)

Load
J (kg.m2)

Weight
kg

YKK4003-6

220

27.8

92.8

9.0

236

2443

YKK4004-6

250

31.5

93.0

10.0

262

2523

YKK4005-6

280

35.2

93.3

10.8

291

2623

YKK4006-6

315

39.5

93.5

11.0

324

2743

YKK4501-6

355

43.9

93.7

14.0

361

3565

15.0

401

3780

16.0

440

3900

17.0

687

4030

27.0

540

4590

32.5

599

4790

34.0

665

4955

6.0

1.8

YKK4502-6

400

49.4

93.8

YKK4503-6

450

55.4

94.1

YKK4504-6

500

61.5

YKK5001-6

560

68.0

YKK5002-6

630

76.4

94.5

YKK5003-6

710

85.8

94.8

YKK5004-6

800

96.6

94.9

40.0

736

5150

YKK5601-6

900

107.2

95.0

64.0

805

6920

YKK5602-6

1000

119.0

95.1

70.0

886

7270

YKK5603-6

1120

133.2

95.2

75.0

927

7520

YKK6301-6

1250

146.8

95.3

139

1068

10000

990

0.83

94.3
94.4
0.7
0.84

0.85
6.5
0.86

YKK6302-6

1400

164.2

95.4

147

1192

10400

YKK6303-6

1600

187.5

95.5

162

1312

10750

YKK4001-8

185

24.7

92.5

11.0

406

2443

YKK4002-8

200

26.6

92.7

12.0

450

2553

YKK4003-8

220

29.2

92.9

13.0

502

2653

YKK4501-8

250

32.7

93.0

16.0

558

3625

17.0

622

3695

0.78

0.8

0.79

5.5

YKK4502-8

280

36.6

93.2

YKK4503-8

315

41.1

93.4

18.0

693

3800

YKK4504-8

355

46.2

93.5

19.0

772

3900

YKK5001-8

400

51.3

93.7

30.0

853

4420

YKK5002-8

450

57.7

34.0

941

4595

YKK5003-8

500

63.8

94.2

38.0

1044

4810

YKK5004-8

560

71.4

94.4

42.0

1160

4995

YKK5601-8

630

78.2

94.5

79.0

1221

6920

YKK5602-8

710

88.1

94.6

87.0

1357

7170

YKK5603-8

800

99.1

94.7

90.0

1505

7250

129

1650

9650

137

1820

10050

743

93.8

YKK6301-8

900

108.8

94.8

YKK6302-8

1000

120.7

94.9

0.80

1.8

0.82
0.7
0.84

6.0

0EE.138.185-2008
Table 3(continuous)
Rated
Type

Technical data of YKK series (6KV) motors (guaranteed value)

Rated

Rated

power current

speed

(kW)

(r/min)

(A)

Efficiency

(%)

YKK6303-8

1120

135.1

YKK6304-8

1250

150.6

YKK4501-10

185

25.9

91.7

YKK4502-10

200

27.9

91.9

YKK4503-10

220

30.6

92.1

YKK4504-10

250

34.8

92.3

YKK4505-10

280

38.8

92.5

YKK5001-10

315

43.0

92.8

YKK5002-10

355

48.3

93.0

YKK5003-10

400

54.3

YKK5004-10

450

61.0

YKK5601-10

500

YKK5602-10

560

YKK5603-10

factor
cos

torque
rated
torque

Locked-

Locked

rotor

rotor

torque

current

rated

rated

torque

current

0.7

6.0

Moment of inertia
Motor
Jm

Load

Weight

J (kg.m2)

kg

(kg.m )
151

2001

10450

160

2204

10850

19.0

698

3605

20.0

775

3670

22.0

865

3725

24.0

902

3840

26.0

1072

3950

36.0

1196

4305

38.0

1332

4445

93.3

42.0

1471

4630

93.4

45.0

1627

4810

65.9

93.6

67.0

1710

6890

73.7

93.7

74.0

1902

7110

630

82.9

93.8

79.0

2116

7340

YKK5604-10

710

93.2

94.0

88.0

2355

7390

YKK6301-10

800

102.1

94.2

132

2615

9850

YKK6302-10

900

114.8

94.3

140

2800

10250

YKK6303-10

1000

127.4

94.4

152

3170

10650

YKK6304-10

1120

142.4

94.6

167

3489

11050

743

590

95.0

Power

Breakdown

95.1

YKK4504-12

185

27.7

91.8

YKK4505-12

200

29.9

92.0

YKK5001-12

220

31.9

92.2

YKK5002-12

250

36.1

92.5

YKK5003-12

280

40.4

YKK5004-12

315

45.4

YKK5601-12

355

49.6

YKK5602-12

400

55.7

YKK5603-12

450

62.7

93.4

YKK5604-12

500

69.4

93.7

YKK6301-12

560

75.6

93.8

YKK6302-12

630

84.9

93.9

YKK6303-12

710

95.6

YKK6304-12

800

107.5

495

1.8

1.8

0.75
0.8

0.76

5.5

1.8

0.78
0.7

6.0

0.80

24.0

1487

3835

26.0

1206

3930

40.0

1347

4280

42.0

1499

4450

92.7

43.0

1672

4575

92.8

47.0

1865

4775

87.0

1967

6860

96.0

2190

7070

103

2411

7280

114

2673

7490

179

2974

9850

191

3312

10250

94.0

208

3688

10650

94.2

272

4098

11050

0.70

0.72

93.0
93.3

0.8

5.5

1.8
0.74
0.7
0.76

6.0

0EE.138.185-2008
10.2 Series of high-voltage three-phase induction motors10kV
Table 4

Technical data of YKK series (10KV) motors (guaranteed value)

Rated

Rated

Rated

power

current

speed

(kW)

(A)

(r/min)

YKK4001-2

220

16.2

YKK4002-2

250

18.3

YKK4003-2

280

20.5

YKK4004-2

315

23.0

93.0

YKK4005-2

355

25.8

93.3

YKK4501-2

400

28.66

93.7

YKK4502-2

450

32.14

94

Type

2975

Power

Breakdow

Moment of inertia

Locked-

Locked

rotor torque

rotor current

Motor Jm

rated torque

rated current

(kg.m2)

J (kg.m2)

92.4

3.5

14.4

2320

92.6

3.8

16.1

2405

4.1

17.7

2432

4.4

19.6

2515

4.7

21.7

2580

8.2

35.2

3625

8.7

37.2

3730

9.2

37.9

3775

Efficiency
(%)

factor
cos

n torque
rated
torque

92.8

0.85

0.6

0.86
0.55
0.86

Load

Weight
kg

YKK4503-2

500

35.60

94.2

YKK4504-2

560

39.80

94.4

9.7

38.6

3930

YKK5001-2

630

44.2

94.6

17.2

63.2

4745

YKK5002-2

710

49.8

94.7

19.1

68.8

4945

YKK5003-2

800

56.0

94.8

21.1

75.5

5145

YKK5004-2

900

62.9

23.0

92.0

5345

YKK5005-2

1000

69.9

95.0

25.2

100.8

5545

YKK5601-2

1120

78.1

95.2

31.8

78.4

7400

YKK5602-2

1250

87.0

95.3

35.7

90.0

7650

YKK5603-2

1400

97.4

95.4

39.8

97.0

7900

YKK6301-2

1600

111.2

95.5

42.7

98.0

8900

YKK6302-2

1800

124.9

95.6

46.0

99.0

9300

YKK6303-2

2000

137.1

95.7

53.0

100.0

9700

YKK4001-4

220

16.6

92.4

5.4

80.2

2375

YKK4002-4

250

18.8

92.6

5.6

90.0

2440

YKK4003-4

280

21.0

92.8

5.8

99.6

2505

YKK4004-4

315

23.6

93.0

6.0

110.6

2565

2985

1.8

0.6
0.55

94.9
0.87

0.88

7.0
1.8

0.83

YKK4005-4

355

25.5

93.3

6.2

123.0

2610

YKK4501-4

400

28.72

93.5

14.4

132

4005

YKK4502-4

450

32.17

93.9

15.3

147

4100

YKK4503-4

500

35.71

16.2

160

4260

YKK4504-4

560

39.91

17.0

174

4295

YKK5001-4

630

44.8

94.4

28.0

201

4710

YKK5002-4

710

50.4

94.6

30.0

220

4960

YKK5003-4

800

56.0

94.8

242

5145

YKK5004-4

900

62.9

94.9

44.0

270

5355

YKK5005-4

1000

69.9

95.0

47.0

292

5565

YKK5601-4

1120

78.2

95.1

44.0

270.0

7450

YKK5602-4
YKK5603-4

1250
1400

86.1
96.4

95.2
95.3

47.0
50.0

292.0
320.0

7700
7950

YKK6301-4

1600

110.0

90.0

350.0

9500

YKK6302-4

1800

123.5

95.0

382.0

9900

1485

1485

0.7

94.0
94.2

95.4
95.5

0.86

32.0

0.87
1.8

0.6

10

0EE.138.185-2008
Table 4 (continuous) Technical data of YKK series (10KV) motors (guaranteed value)

Type

Rated

Rated

Rated

power

current

speed

(kW)

(A)

(r/min)

Efficiency

(%)

YKK6303-4
YKK4501-6
YKK4502-6
YKK4503-6

2000
220
250
280

110.0
17.3
19.6
21.9

YKK4504-6

315

23.9

YKK4505-6

355

26.5

93.1

YKK4506-6

400

29.8

93.3

YKK5001-6
YKK5002-6
YKK5003-6
YKK5004-6
YKK5005-6

450
500
560
630
710

33.5
37.0
40.9
45.9
51.6

YKK5601-6
YKK5602-6
YKK5603-6
YKK5604-6
YKK6301-6
YKK6302-6
YKK6303-6
YKK4501-8

800
900
1000
1120
1250
1400
1600
220

58.0
65.1
71.5
80.0
89.1
98.5
112.5
18.2

YKK4502-8
YKK4503-8
YKK5001-8
YKK5002-8
YKK5003-8
YKK5004-8
YKK5005-8
YKK5601-8
YKK5602-8
YKK5603-8
YKK5604-8
YKK6301-8
YKK6302-8
YKK6303-8
YKK5001-10
YKK5002-10
YKK5003-10

250
280
315
355
400
450
500
560
630
710
800
900
1000
1120
220
250
280

20.6
23.0
25.5
28.6
31.8
35.7
39.0
43.9
48.7
54.9
59.5
66.8
74.2
83.0
19.2
21.8
23.7

YKK5003-10
YKK5003-10
YKK5601-10
YKK5602-10
YKK5603-10
YKK5604-10

315
355
400
450
500
560

26.5
29.4
33.3
36.6
39.5
44.3

988

988

137.3
92.0
92.2
92.5
92.8

93.5
93.9
94.1
94.4
94.6
94.8
94.9
95.0
95.1
95.3
95.4
95.5
92.0

741

743

593

92.2
92.5
92.8
93.1
93.2
93.4
93.8
94.4
94.5
94.5
94.6
94.8
94.9
95.0
91.9
92.1
92.4
92.6
92.8
93.1
93.2
93.4
93.5

Power
factor
cos

Breakdown

torque
rated
torque

Locked-

Locked

rotor

rotor

torque

current

rated

rated

torque

current

0.87
0.80
0.82
0.83
0.7

0.83
0.84
0.85

6.0

0.84
0.85

0.6

0.86

0.76

1.8

Jm

Weight

Load

kg

J
2

(kg.m )

101.0
15.5
16.3
17.4

423.0
210.0
235.0
260.0

10000
3890
3930
4010

18.4

290.0

4090

19.5

320.0

4160

20.4

345.0

4305

31.0
33.0
35.0
50.0
60.0

400
440
485
540
599

4590
4790
4955
5150
5345

50.0
60.0
63.0
67.0
121.0
128.0

540
599
665
736
805
886

7150
7500
7750
7950
10350
10950

135.0

970

11100

(kg.m )

19.0

423

3930

20.0
21.0
34.0
36.0
38.0
43.0
46.0

476
528
588
656
730
810
890

4015
4125
4595
4810
4995
5180
5365

6.0

63.0
67.0
70.0
74.0
145.0
151.0

810
890
988
1098
1221
1357

7500
7750
7950
8150
10000
10400

166.0
38.0
33.0
35.0

1505
698
440
485

10800
4630
4810
4990

78.0
83.0
78.0
83.0
87.0

540
599
1014
1131
1261

5170
5350
7000
7150
7500

92.0

1403

7750

0.78

0.79
0.7
0.82

5.5

0.74
0.75
0.76
0.77
0.78

Motor

5.5

0.77

0.72

Moment of inertia

6.0

11

0EE.138.185-2008
Table 4 (continuous) Technical data of YKK series (10KV) motors (guaranteed value)

Type

Rated

Rated

Rated

power

current

speed

(kW)

(A)

(r/min)

Efficiency

(%)

YKK5605-10

630

49.8

93.7

YKK6301-10

710

55.9

93.9

YKK6302-10

800

62.8

590

94.3

YKK6303-10

900

70.6

94.4

YKK6304-10

1000

76.4

94.5

YKK5004-12

220

19.2

YKK5005-12

250

YKK5601-12

Power
factor
cos

Breakdown

torque
rated
torque

Locked-

Locked

Moment of inertia

rotor

rotor

Motor

torque

current

Jm

rated

rated

(kg.m2)

torque

current

0.78

Load
J (kg.m2)

Weight
kg

97.0

1544

7950

153.0

1710

10200

162.0

1902

10600

169.0

2116

11000

178.0

2355

11400

91.8

22.0

4300

4300

21.8

92.0

24.0

4500

4500

280

24.4

92.1

88.0

1135

7000

YKK5602-12

315

27.4

92.3

97.0

1210

7150

YKK5603-12

355

30.4

92.5

100

1418

7500

YKK5604-12

400

34.6

92.7

108

1580

7750

YKK5605-12

450

38.4

92.8

115

1763

7950

YKK6301-12

500

42.4

93.2

139

1967

10200

YKK6302-12

560

47.4

93.5

156

2190

10600

495

YKK6303-12

630

53.2

93.6

YKK6304-12

710

59.1

93.7

0.80

0.72

0.73

0.74

1.8

0.7

6.0

172

2411

11000

180

2672

11400

12

0EE.138.185-2008

11 Overall and mounting dimensions


11.1 YKK range of high-voltage three-phase induction motors

(6kV)

Mounting dimension and tolerance


Frame no. of
poles
size

Basic Basic
dim.

355

dim.

C
Basi
c
dim.

dimensi
on dev.

630 900 315

355
4
400
2
375
710 1000
400 48
335
450
2
400
450
4
800 1120
355
450 612
500

560
900 1250

500
4
475
500 612
560
2
560
560
4 1000 1400
500
560 612
630
4
1120 1600 530
630 612

Basi Dimensi
c

on

dim.

dev.

80

+0.0
+0.011

Basic dimensi Basic


dim. on dev.

170 0.5

100
210 0.57
0.5
90
+0.035 170
110 +0.013
90
210
120
4.0

+0.04
130 +0.015

100 +0.035
+0.013

250
0.57

210

120
130
130 +0.04 250
150 +0.015
160
170 +0.04 300 0.70
180 +0.013

dim.

Dimensi
on
dev.

22

Basic
dim.

71

dimens
ion
dev.

Basic
dim.

Dimens
ion
dev.

355

90
81
400
100
0
81
- 0.2
109
450
0
32 - 0.062
119
28
32

90
109
119

500

32
0
36 - 0.062 138 0 560
147 - 0.3
40
157
630
45
165

dim.

28

28
0
25 - 0.052
28
25

0
- 0.052

Basic

dimens
ion

AA

AB

AC

AD

AG

BA

BB

BC

BD

GD

+0.52
0

800 1004 740 599 550 1360 470 210

14

16
469 281 14
900 1104 790 650 630 1500
501 249 16
14
980 1184 940 792 610 1620 548 262

HD

+0.62
0

25 100 1280
25

18

200
42

HB

dev.

35

0
- 1.0

HA

14

1445

82

1650

1990
1990
2140
2180
2335
2330
2270

30
525 407 16
1200 1324 1009 862 740 1730
510 355
585 345

42

1220 1460 1045 900 720 1860

48

1260 1500 1065 918 670 2000 710 290

2650
320 1860

18

2550

20

570 360
22

220 2400

3250

392 2700

3450

40

12

0EE.138.185-2008

11.2 YKK range of high-voltage three-phase induction motors

(10kV)

Overall dimension

Mounting dimension and tolerance


Frame no. of
poles

size

400

Basic Basic Basic


dim.

400

dim.

dim.

800 1120 400

dimens
ion
dev.

Basic
dim.

Dimensi
on
dev.

Basic dimensi Basic Dimension Basic


dim. on dev. dim.

dev.

dim.

90

170

25

81

100

210 0.57

28

100

450 2
400
90 +0.035 170
800 1120
450 46
355 4.0 110 +0.013
500 2*
210
560
100
0.57
500
4
120
900 1250
475
+0.04
500 612
130 +0.015 250

25
28
32

0
-0.052

dimens
ion
dev.

Basic
dim.

Dimens
ion
dev.

Basic
dim.

dimens
ion

AA

560 2*
0
560
32
138
560
4 1000 1400
560
150 +0.04 300 0.65 36 - 0.062
0
500
+0.015
- 0.3
560 612
40
147
160
4.0
630
4
170
40
157
300
630
0.57
1120 1600 530
+0.04
630 612
180 +0.013
45
165

AC

AD

AG

BA

BB

BC

BD

GD

HA

HB

800 1104 940


35

980
200
+0.62
0

1184 940

792

630

16

82 1650 2335

14
16
340 525 16

2300
30 140 1660 2350
2650
170 1800 2500

1620 262 548

610

1200 1324 1009 862 740 1730

355 510 18

2600

42
585 345
210 12201460
48

HD

dev.

400

81 0
450
100 - 0.2
90
0
109
500 - 1.0
119

AB

1045 900 720 1860

20

220 2120 2800

570 360

22
200 1260 1500 1065 918 670 2000 710 290 22
220
25

40
2400 3450
392

2700 3450

13

0EE.138.185-2008
11.3 YKK range of high-voltage three-phase induction motors

(6kv, 10kV)

Overall dimension

Mounting dimension and tolerance


Frame no. of
poles

size

Basic Basic Basic


dim.

630

dim.

dim.

dimens
ion
dev.

Basic
dim.

1120 1600 530 4.0 140

Dimensi
on
dev.

+0.04
+0.015

Basic dimensi Basic

Dimensi
on

dim. on dev. dim.

250 0.57

36

dev.

0
- 0.062

Basic
dim.

128

dimens
ion
dev.

0
- 0.2

Basic
dim.

630

Dimens
ion
dev.

0
- 1.0

Basic
dim.

dimens
ion

AA

AB

AC

AD

AG

BA

BB

BC

BD

GD

HA

670 2000 710 290 22

40

HB

HD

dev.

+0.62
48 0

200 1260 1500 1065 918

392 2400 3450

Note 1the cooling method of YKK630-2 is IC616, 355-630 is IC611


Note 2YKK450-2YKK500-2YKK560-2YKK630 24 are with sleeve bearing.
Note 3Motors that the power 2000KW are provided with auxiliary terminal box

14

0EE.138.185-2008

15

Das könnte Ihnen auch gefallen