Sie sind auf Seite 1von 6

Simply smart: First choice for standard applications

www.siemens.com/lowvoltage

Accessories Connecting sets

3 2

Auxiliary trips

11

12

Switches 1 Locking type lever

9 13 10

Hand drives

26 14

15

16

17

25

23 21

24 22

18

19

20

Highlights at a glance Flexibility All components can be combined in a modular way Available in 3- or 4-pole, fixed-mounted, plug-in or withdrawable design Ease of use User-friendliness in planning, configuration, installation and operation Only a few components to cover the entire spectrum from 10 A to 1,600 A Safety and reliability Conforms to international standards and approvals Compatibility and safe interaction between products and systems

1. 3VT1 circuit breaker 2. Circular conductor terminals with cover 3. Front connection 4. Rear connection 5. Auxiliary wiring terminals 6. Connecting busbars with increased pole spacing 7. Adapter to install on 35 mm DIN rail 8. Insulating barriers 9. Signaling switch 10. Auxiliary switch 11. Shunt trip unit 12. Undervoltage trip unit 13. Locking-type lever

14. Front hand drive unit 15. Front hand drive unit 16. Right side hand drive unit 17. Left side hand drive unit 18. Non-locking hand drive lever 19. Locking hand drive lever 20. Locking hand drive lever 21. Hand drive bearing 22. Hand drive bearing 23. Telescopic extension shaft 24. Extension shaft 25. Mechanical interlocking 26. Mechanical parallel switching

3VT molded-case circuit breakers Compact and safe up to 1,600 A


3VT molded-case circuit breakers are an intelligent and cost-effective way to achieve high performance and availability. These 3VT circuit breakers feature a compact design to save space, thanks to the modular versatility of the circuit breakers ranging from 10 A to 1,600 A. You can choose either thermal-magnetic or electronic trip units. In addition, the entire range has only three families of internal accessories. The result: maximum benefit, minimum expense.

Technical features1 Rated current range from 10 A to 1,600 A Electronic overcurrent trip units from 250 A (3VT250) upwards 3- and 4-pole versions Fixed-mounted, plug-in and draw-out versions Wide range of standard external accessories Conforms to the following standards: IEC 60947-1, IEC 60947-2, IEC 60947-3
1 In cases where higher ratings and communications capabilities are required, please see SENTRON 3VL circuit breakers

Exchangeable electronic trip units: 3VT2 (250 A) to 3VT5 (1,600 A) Wide range of electronic trip units coinciding with application loads Authorized persons can easily exchange electronic trip units on their own Adjustment range from 40 to 100 In A switch disconnector block can be used in place of electronic trip units as a switch disconnector in MCCB design, and to have access to the complete range of MCCB accessories

Wide range of operating mechanisms: Rotary handles (front- or side-operated) Motor mechanism with or without cycle counter

Technical specifications

3VT1 Frame size maximum rated current Rated current ln A A 160 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160 690 max. 690 V AC 3/4 kA kA
Electrical Mechanical

3VT2 N 250

3VT2 H

3VT3 N 630

3VT3 H

3VT4 H 1,000 315, 630, 800, 1,000 690 max. 690 V AC 3 65 36 10,000 4,000 -

3VT5 H 1,600 630, 1,000, 1,250, 1,600 690 max. 690 V AC 3 55 36 10,000 4,000 -

100, 160, 200, 250

250, 315, 400, 500, 630 690 max. 690 V AC 3/4 36 18 20,000 5,000 65 36

Rated insulation voltage Ui Rated operational voltage Ue Number of poles Rated ultimate short-circuit breaking capacity lcu up to 415 V AC/50 Hz Rated service short-circuit breaking capacity lcs up to 415 V AC/50 Hz Endurance

V V

690 max. 690 V AC 3/4 36 18 30,000 3,000 65 36

25 13 20,000 6,000

Overcurrent release

Thermalmagnetic trip unit Electronic trip unit

75 mm 100 mm 130 mm 70 mm

105 mm 140 mm 225 mm 117 mm

140 mm 185 mm 275 mm 117 mm

210 mm 494 mm 157 mm

210 mm 494 mm 157 mm

Outline Dimension

Width 3-pole 4-pole Height Depth

Highly efficient and economical: 3VT circuit breakers


Today, the economic success of industrial and infrastructure projects more than ever depends on the power supply a key aspect for availability, performance and productivity, and a lever to boost overall economic efficiency. Thats why choosing the right circuit breakers is so crucial to keeping expenses down while, at the same time, optimizing performance. With the new standard line of 3VT circuit breakers, Siemens offers an economic solution for the entire power range from 10 A to 1,600 A the smart solution to protect plants, capacitors, transformers and generators. Both for infrastructure applications as well as in the area of industrial switchgear technology, 3VT circuit breakers can be used as incoming and outgoing circuit breakers to distribute power in low-voltage switchgear. Available in several design variations, the modular circuit breakers are highly user-friendly, while also offering a high degree of safety and reliability.

Fax order +49 (911)978-3321 CD/Z1366


MANAGING

Power Management System

Information material Please send the selected information material to the following address

DISTRIBUTING

SIVACON switchboards SIVACON busbar trunking systems SIVACON cubicle systems SENTRON circuit breakers SENTRON switch disconnectors SENTRON power monitoring devices Dimensioning with SIMARIS design Conguring, visualizing and controlling with SIMATIC powercontrol Totally Integrated Power
Telephone/Fax Street, ZIP/city/country Company/department

SWITCHING, PROTECTING & MEASURING

Name

POWER DISTRIBUTION SOFTWARE

E-mail

Siemens AG Industry Sector Industry Automation P.O. Box 48 48 90327 NUREMBERG GERMANY

Subject to change without prior notice 02/08 Order No. E20001-A410-P307-V1-7600 2100/10787 EVSN.52.8.01 PA 02085.0 DISPO 27604 Printed in Germany Siemens AG 2008

www.siemens.com/automation

The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.