Beruflich Dokumente
Kultur Dokumente
Jensen
Variables:
Uncertainties 0.25 mL
Sensors give data to the millionth place data will be rounded to the hundredths place (uncertainty not necessary)
Controlled Variables
Units
Possible effect(s) on results An unstable temperature can cause a fluctuation in fermentation rate. A temperature that is too high can kill the yeast, thus preventing fermentation from occurring for the time measured. More yeast would metabolize more of the sugar in a shorter period of time. This would cause an increase in CO2 gas pressure reading. A higher amount of juice (commercialized or natural) could lead to an increased fermentation rate. A lesser amount could lead to a food shortage, causing a plateau of the CO2 gas pressure reading. The purpose of the vegetable oil was to create an anaerobic environment for the yeast by cutting off its oxygen supply. If an anaerobic environment is not maintained than aerobic fermentation will affect the results. An inconsistent time period in which fermentation is observed would make comparing the data more difficult.
Method for Control Thermometer reading (maintain at 40C, checked every minute) 2.5 mL of yeast was placed in each test tube
40C
mL
mL
mL
2 mL of vegetable oil was used to cover the yeast and fruit juice in each test tube Each trial was observed for 10 minutes (600 seconds)
Time observed
seconds
Test tube containing Yeast, Independent Variable, and oil immersed in the hot water bath
Materials: computer 18 150 mm test tube Vernier computer interface 1 L beaker (for water bath) Logger Pro basting bulb or Beral pipette Vernier Gas Pressure Sensor Distilled water l-hole rubber stopper assembly test tube rack plastic tubing with Luer-lock fitting thermometer 5% glucose solution yeast suspension vegetable oil ring stand utility clamp 1mL pipet 10 mL graduated cylinder Commercialized Orange Juice (Tropicana) Juiced Orange (Fruit) Commercialized Apple Juice (Motts) Juiced Apple (Fruit)
3
Procedure: 1. A gas pressure sensor was connected to the computer interface. 2. Plastic tubing was connected to the valve on the Gas Pressure Sensor. 3. A water bath was prepared for the yeast by filling a large 1-L beaker with around 700 mL of water and this beaker was placed on a hot plate. Temperature was kept at 40C and monitored using a thermometer. 4. The yeast was activated by adding 100mL of distilled water to 7 grams of yeast in a flask. The flask with the yeast was placed in a water bath heated to nearly 40C for at least 10 minutes. 5. 5 Test tubes were obtained and labeled with Natural Apple. 6. 2.5 mL of the Natural Apple, which was previously juiced, was placed into 1 test tube. 7. The yeast suspension was obtained and gently swirled. 2.5 mL of yeast was measured and added to the Natural Apple Juice already in the tube. This mixture was mixed gently. 8. Using a 1 mL pipet, 2 mL of vegetable oil was added to the top of the yeast/Natural Apple Juice mixture. 9. Steps 5-7 was repeated 4 more times. 10. 3 of the 5 test tubes were placed in the hot water bath. 11. 3 single-holed rubber-stoppers were inserted into the 3 test tubes, which were then secured with a utility clamp and ring stand. 12. Most of the test tube was covered by the water in the hot water bath. Test tubes were incubated for 10 minutes and the temperature was checked and accordingly adjusted every minute. 13. The rate of fermentation, measured in kPA, was collected for 10 minutes using the LoggerPro program and Vernier Gas Pressure Sensor. 14. Steps 10-13 were repeated for the remaining 2 trials. 15. Steps 5-14 were repeated for each Commercialized Apple, Natural Orange, and Commercialized Orange. 16. 1 test tube was obtained and labeled Negative Control.
4
17. 2.5 mL of Distilled water was placed into the test tube. 18. The yeast suspension was obtained and gently swirled. 2.5 mL of yeast was measured and added to the Distilled water already in the tube. This mixture was mixed gently. 19. Using a 1 mL pipet, 2 mL of vegetable oil was added to the top of the yeast/Distilled water mixture. 20. The test tube was placed in the hot water bath. 21. A single-holed rubber-stopper was inserted into the test tube, which was then secured with a utility clamp and ring stand. 22. Steps 12 and 13 were repeated. 23. 1 test tube was obtained and labeled Positive Control 24. 2.5 mL of 5% glucose solution was placed into the test tube. 25. Steps 18-22 were repeated for the positive control. 26. As soon as the data collection was complete, the plastic tubing connector was disconnected from the rubber stopper, and the rubber stopper was removed from the test tube. Contents of the test tubes were discarded.
Data Collection
Raw Data Tables:
Commercialized Orange Juice Pressure Values (kPa) Time (Minute) 0 1 2 3 4 5 6 7 8 9 10 Trial 1 103.65 104.62 105.81 107 108.41 109.83 111.3 112.66 114.13 115.66 117.19 Trial 2 104.42 105.5 106.58 107.6 108.85 110.05 111.3 112.72 114.03 115.56 117.04 Trial 3 104.05 105.12 106.43 107.79 109.09 110.34 111.7 113.12 113.29 114.48 115.78 Trial 4 105.44 106.41 107.37 108.28 109.36 110.5 111.58 112.72 113.97 115.33 116.7 Trial 5 105.35 106.31 107.28 108.13 108.98 109.94 110.91 112.1 113.18 114.31 115.61
*Uncertainties not necessary, data logger measures up to the millionth decimal place
Natural Orange Fruit Pressure Values (kPA) Time (Minute) 0 1 2 3 4 5 6 7 8 9 10 Trial 1 Trial 2 Trial 3 Trial 4 Trial 5 107.17 104.87 103.99 105.16 103.51 107.74 105.38 104.73 105.74 104.64 108.32 105.781 105.29 106.48 106.01 108.95 106.24 105.97 107.34 107.43 109.92 106.86 106.94 108.26 108.91 111.07 107.71 108.07 109.18 110.39 112.39 108.68 109.26 110.09 111.81 113.76 109.59 110.57 111.07 113.11 115.25 110.78 112.04 111.98 114.48 116.8 112.04 113.46 112.73 115.73 118.52 113.29 115.1 113.42 116.81
*Uncertainties not necessary, data logger measures up to the millionth decimal place
Commercialized Apple Juice Pressure Values (kPa) Time (Minute) 0 1 2 3 4 5 6 7 8 9 10 Trial 1 108.21 108.61 109.24 110.03 110.83 111.73 112.64 113.78 114.80 116.11 117.24 Trial 2 106.83 107.35 107.93 108.63 109.20 109.90 110.53 111.29 112.04 112.85 114.00 Trial 3 105.49 106.11 106.79 107.65 108.16 108.67 109.24 110.03 110.71 111.73 112.81 Trial 4 104.00 104.46 105.22 106.03 106.78 107.41 108.11 108.92 109.78 110.94 112.04 Trial 5 108.16 110.09 112.02 114.06 116.11 117.98 120.19 122.41 124.68 127.01 129.68 Trial 6 104.90 105.18 105.57 105.97 106.36 106.76 106.98 101.45 103.47 103.09 103.82
*Uncertainties not necessary, data logger measures up to the millionth decimal place
Natural Apple Fruit Pressure Values (kPa) Time (Minute) 0 1 2 3 4 5 6 7 8 9 10 Trial 1 103.70 104.49 105.29 106.37 107.39 108.41 109.38 110.63 111.70 112.61 113.46 Trial 2 104.77 105.17 105.74 106.43 107.12 107.86 108.72 109.63 110.55 111.57 112.66 Trial 3 104.48 105.16 106.24 107.26 108.17 108.85 109.59 110.39 111.24 111.98 112.66 Trial 4 107.40 107.80 108.66 109.80 110.89 111.98 113.06 114.32 115.58 116.83 118.03 Trial 5 107.71 108.62 109.53 110.50 111.47 112.38 113.46 114.60 115.62 116.70 117.89
*Uncertainties not necessary, data logger measures up to the millionth decimal place
Control Values (kPA) Time (Minute) Positive Negative 0 106.54 102.92 1 107.00 103.09 2 107.92 103.26 3 108.78 103.48 4 109.81 103.6 5 6 7 8 9 10 110.78 111.70 112.56 113.42 114.28 115.25 103.65 103.65 103.82 103.88 104.05 104.11
*Positive control data was collected by Julia Vanzelli; Negative control data was collected by Miranda Shauger
*Uncertainties not necessary, data logger measures up to the millionth decimal place
Presentation:
Commercialized Apple Juice Pressure Value Averages (kPa) Time Average Standard (Minute) between Deviation trials 0 106.538 1.62 1 107.324 1.95 2 108.24 2.31 3 109.28 2.72 4 110.216 3.23 5 111.138 3.71 6 112.142 4.30 7 113.286 4.84 8 114.402 5.41 9 115.728 5.91 10 117.154 6.51
Natural Apple Fruit Pressure Value Averages (kPa) Time Average Standard (Minute) between Deviation trials 0 106.81 1.10 1 106.90 0.95 2 107.16 0.99 3 107.76 1.19 4 108.44 1.38 5 109.17 1.53 6 110.01 1.62 7 111.00 1.76 8 112.08 1.84 9 113.25 1.91 10 114.41 1.95
Commercialized Orange Juice Pressure Value Averages (kPa) Time Average Standard (Minute) between Deviation trials 0 104.58 0.71 1 105.59 0.69 2 106.69 0.58 3 107.76 0.45 4 108.94 0.31 5 110.13 0.25 6 111.36 0.27 7 112.66 0.33 8 113.72 0.40 9 115.07 0.56 10 116.46 0.65
Natural Orange Fruit Pressure Value Averages (kPa) Time Average Standard (Minute) between Deviation trials 0 104.94 1.26 1 105.65 1.13 2 106.38 1.04 3 107.19 1.05 4 108.18 1.17 5 109.28 1.29 6 110.45 1.43 7 111.62 1.57 8 112.91 1.68 9 114.15 1.82 10 115.43 2.01
10
Commercialized Orange Juice Trial 1 Trial 2 Trial 3 Trial 4 Trial 5 Average Pressure Change (kPa) 13.54 12.62 11.73 11.26 10.26 --Fermentation Rate (kPa/minute) 1.35 1.26 1.17 1.13 1.03 1.19
Natural Orange Fruit Trial 1 Trial 2 Trial 3 Trial 4 Trial 5 Average Pressure Change (kPa) 11.35 8.42 11.11 8.26 13.3 --Fermentation Rate (kPa/minute) 1.14 0.84 1.11 0.83 1.33 1.05 Commercialized Apple Juice Trial 1 Trial 2 Trial 3 Trial4 Trial 5 Average Pressure Change (kPa) 9.03 7.17 7.33 8.03 21.51 --Fermentation Rate (kPa/minute) 0.9 0.72 0.73 0.8 2.15 1.06
Natural Apple Fruit Trial 1 Trial 2 Trial 3 Trial 4 Trial 5 Average Pressure Change (kPa) 9.77 7.89 8.17 10.63 10.18 --Fermentation Rate (kPa/minute) 0.98 0.79 0.82 1.06 1.02 0.93 Controls Positive 8.71 .87
11
12
13
14
may also have happened with the yeast, which would mean more yeast in this trial than the others. Further investigations of this experiment could include the same experiment with more trials therefore a t-test may be performed. Additionally, the rate of fermentation of fruits with varying pHs would be a good way to further investigate this topic, since oranges have a lower pH than apples. Evaluation: Evaluating the Procedure: One anomoly which occurred during this investigation, raw data trial 6 of the commercialized apple juice, was caused by the rubber stopper not staying in the test tube. This was caused by excessive vegetable oil near the rim of the test tube on the inside. The vegetable oil provided lubrication, so as the pressure increased, the rubber stopper was pushed further out of the test tube, not maintaining the pressure once it popped out of the test tube. This data point was removed from the processed data. Improving the Investigation: To alter the procedure to avoid this from happening in future trials, it is suggested that after the vegetable oil is added, the inner part of the test tube which the rubber stopper will be should be whiped clean with a tissue/paper towel/cloth of some sort to remove the oil. Additionally, more trials would improve the investigation. Bibliography FDA. (2008). Raw fruits poster. U S Food and Drug Administration. Retrieved January 15, 2012, from: http://www.fda.gov/Food/LabelingNutrition/FoodLabelingGuidanceRegulatoryInformati on/InformationforRestaurantsRetailEstablishments/ucm063482.htm Masterman, D., & Redding, K. (2006). Biology with computers. (3 ed.). Beaverton, OR: Vernier Software & Technology. Motts. (2011). Motts products. Retrieved January 15, 2012, from: http://www.motts.com/Products/FamilyHealthyFavorites/MottsOriginal100AppleJuice. aspx Tropicana. (2011). Tropicana products. Retrieved January 15, 2012, from: http://www.tropicana.com/#/trop_products/productsLanding.swf?TropicanaPurePremi um/21
15