Sie sind auf Seite 1von 511

Index (Repairing)

Sl No.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52

Bridge Name
Repairing Estimate Bridge no : 213/1 Quantity Calculation Bridge no : 213/1 Repairing Estimate Bridge no : 223/4 Quantity Calculation Bridge no : 223/4 Repairing Estimate Bridge no : 228/1 Quantity Calculation Bridge no : 228/1 Repairing Estimate Bridge no : 229/1 Quantity Calculation Bridge no : 229/1 Repairing Estimate Bridge no : 234/1 Quantity Calculation Bridge no : 234/1 Repairing Estimate Bridge no : 235/3 Quantity Calculation Bridge no : 235/3 Repairing Estimate Bridge no : 237/1 Quantity Calculation Bridge no : 237/1 Repairing Estimate Bridge no : 240/1 Quantity Calculation Bridge no : 240/1 Repairing Estimate Bridge no : 245/3 Quantity Calculation Bridge no : 245/3 Repairing Estimate Bridge no : 250/4 Quantity Calculation Bridge no : 250/4 Repairing Estimate Bridge no : 251/1 Quantity Calculation Bridge no : 251/1 Repairing Estimate Bridge no : 252/1 Quantity Calculation Bridge no : 252/1 Repairing Estimate Bridge no : 255/1 Quantity Calculation Bridge no : 255/1 Repairing Estimate Bridge no : 255/2 Quantity Calculation Bridge no : 255/2 Repairing Estimate Bridge no : 259/1 Quantity Calculation Bridge no : 259/1 Repairing Estimate Bridge no : 259/2 Quantity Calculation Bridge no : 259/2 Repairing Estimate Bridge no : 259/3 Quantity Calculation Bridge no : 259/3 Repairing Estimate Bridge no : 260/1 Quantity Calculation Bridge no : 260/1 Repairing Estimate Bridge no : 260/2 Quantity Calculation Bridge no : 260/2 Repairing Estimate Bridge no : 260/4 Quantity Calculation Bridge no : 260/4 Repairing Estimate Bridge no : 260/5 Quantity Calculation Bridge no : 260/5 Repairing Estimate Bridge no : 260/6 Quantity Calculation Bridge no : 260/6 Repairing Estimate Bridge no : 264/1 Quantity Calculation Bridge no : 264/1 Repairing Estimate Bridge no : 264/2 Quantity Calculation Bridge no : 264/2 Repairing Estimate Bridge no : 265/1 Quantity Calculation Bridge no : 265/1 Repairing Estimate Bridge no : 266/1 Quantity Calculation Bridge no : 266/1

Page no
2-5 6-8 9 - 12 13 - 15 16 - 19 20 - 22 23 - 26 27 - 29 30 - 33 34 - 36 37 - 40 41 - 43 44 - 48 49 - 51 52 - 55 56 - 57 58 - 61 62 - 64 65 - 68 69 - 71 72 - 75 76 - 78 79 - 82 83 - 85 86 - 89 90 - 92 93 - 96 97 - 99 100 - 103 104 - 105 106 - 109 110 - 112 113 - 116 117 - 119 120 - 123 124 - 126 127 - 130 131 - 132 133 - 136 137 - 139 140 - 143 144 - 146 147 - 150 151 - 153 154 - 157 158 - 160 161 - 164 165 - 167 168 - 171 172 - 174 175- 178 179 - 181

Index (Bridge Estimate)


Sl No
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53

Bridge Name
Abstract Cost Estimate Bridge No : 209/1 Quantity Calculation Bridge No : 209/1 Cost Estimate Bridge No : 213/1 Quantity Calculation Bridge No : 213/1 Cost Estimate Bridge No : 223/4 Quantity Calculation Bridge No : 223/4 Cost Estimate Bridge No : 226/1 Quantity Calculation Bridge No : 226/1 Cost Estimate Bridge No : 228/1 Quantity Calculation Bridge No : 228/1 Cost Estimate Bridge No : 229/1 Quantity Calculation Bridge No : 229/1 Cost Estimate Bridge No : 232/1 Quantity Calculation Bridge No : 232/1 Cost Estimate Bridge No : 234/1 Quantity Calculation Bridge No : 234/1 Cost Estimate Bridge No : 235/3 Quantity Calculation Bridge No : 235/3 Cost Estimate Bridge No : 237/1 Quantity Calculation Bridge No : 237/1 Cost Estimate Bridge No : 240/1 Quantity Calculation Bridge No : 240/1 Cost Estimate Bridge No : 241/1 Quantity Calculation Bridge No : 241/1 Cost Estimate Bridge No : 245/3 Quantity Calculation Bridge No : 245/3 Cost Estimate Bridge No : 250/4 Quantity Calculation Bridge No : 250/4 Cost Estimate Bridge No : 251/1 Quantity Calculation Bridge No : 251/1 Cost Estimate Bridge No : 252/1 Quantity Calculation Bridge No : 252/1 Cost Estimate Bridge No : 255/1 Quantity Calculation Bridge No : 255/1 Cost Estimate Bridge No : 255/2 Quantity Calculation Bridge No : 255/2 Cost Estimate Bridge No : 259/1 Quantity Calculation Bridge No : 259/1 Cost Estimate Bridge No : 259/2 Quantity Calculation Bridge No : 259/2 Cost Estimate Bridge No : 259/3 Quantity Calculation Bridge No : 259/3 Cost Estimate Bridge No : 260/1 Quantity Calculation Bridge No : 260/1 Cost Estimate Bridge No : 260/2 Quantity Calculation Bridge No : 260/2 Cost Estimate Bridge No : 260/4 Quantity Calculation Bridge No : 260/4 Cost Estimate Bridge No : 260/5 Quantity Calculation Bridge No : 260/5 Cost Estimate Bridge No : 260/6 Quantity Calculation Bridge No : 260/6

Page No
1-4 5-9 10 - 11 12 - 15 16 - 18 19 - 22 23 - 25 26 - 29 30 - 31 32 - 35 36 - 38 39 - 42 43 - 45 46 - 50 51 - 52 53 - 56 57 - 59 60 - 63 64 - 66 67 - 70 71 - 73 74 - 77 78 - 80 81 - 85 86 - 87 88 - 91 92 - 94 95 - 98 99 - 101 102 - 105 106 - 108 109 - 112 113 - 115 116 - 119 120 - 122 123 - 126 127 - 129 130 - 133 134 - 136 137 - 140 141 - 143 144 - 147 148 - 150 151 - 154 155 -157 158 - 161 162 - 164 165 - 168 169 - 171 172 - 175 176 - 178 179 - 182 183 - 185

Sl No
54 55 56 57 58 59 60 61 62

Bridge Name
Cost Estimate Bridge No : 264/1 Quantity Calculation Bridge No : 264/1 Cost Estimate Bridge No : 264/2 Quantity Calculation Bridge No : 264/2 Cost Estimate Bridge No : 265/1 Quantity Calculation Bridge No : 265/1 Cost Estimate Bridge No : 266/1 Quantity Calculation Bridge No : 266/1 Annexure-I

Page No
186 - 189 190 - 192 193 - 196 197 - 199 200 - 203 204 - 206 207 - 210 211 - 213 214

Index

Sl No. 1 2 3 4 5

Bridge Name Abstract of Cost for ROB Cost Estimate for ROB No. 222/1 Cost Estimate for ROB No. 227/1 Cost Estimate for ROB No. 238/2 Cost Estimate for ROB No. 243/1

Page No. 1 2 3 4 5

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam.

Abstract of Bridge
Sl no
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Chainage 208415 212964 222595 225454 227462 228087 231240 233214 234859 236259 239322 240272 244803 249990 250350 251630 254000 254750 258170 258380 258590 259015 259230 259580 259685 259870 Bridge Number 209/1 213/1 223/4 226/1 228/1 229/1 232/1 234/1 235/3 237/1 240/1 241/1 245/3 250/4 251/1 252/1 255/1 255/2 259/1 259/2 259/3 260/1 260/2 260/4 260/5 260/6 Foundation Substructure Superstructure 83715247 3843254 7490574 244385207 6465518 5996341 65021408 4931416 6536365 4360989 4056387 384107664 3568408 4674659 5410407 3146003 3314720 5242120 3174818 2966473 11491302 7056378 6602668 4445961 4191425 4841176 7631471 4361152 5663192 23916554 11477347 10441881 5311920 8773643 5794902 3019475 6086571 30270892 3266608 3966948 3043138 2186448 5161212 2220405 1290626 1955483 7172930 3516355 8643895 2586142 2674023 2464563 46683197 4996144 7657806 84373397 7688495 7360981 17303325 5345836 7660685 4131320 5259062 99342251 5381863 5451262 5871868 4660377 4822344 5654614 4556071 4704570 10273280 8207648 6165614 5632670 5652421 5332024 Protection work 4479733 1661894 1376013 10811927 1441941 1592802 12290131 1353616 1220261 738296 1068934 12883592 853013 954638 989581 729730 773338 1009724 601683 694720 1866128 1303642 1251493 864840 901225 821020 Total Amount 142509648 14862444 22187585 363487085 27073301 25392005 99926784 20404511 21212213 12250080 16470954 526604399 13069892 15047507 15314994 10722558 14071614 14126863 9623198 10321246 30803640 20084023 22663670 13529613 13419094 13458783

27 28 29 30

263570 263955 264876 265310

264/1 264/2 265/1 266/1

5804558 2897694 3087778 7542217

2469928 1501263 2298645 3229441

4822344 4610317 4796887 5819061

773345 644714 754574 1009840 Total-

13870175 9653988 10937884 17600559 1,560,700,310

Executive Engineer, PWD Nagaon NH Division, Nagaon

Widening & Rehabiliation


Sl no Chainage Bridge Dismentaling Foundation Number 213/1 223/4 228/1 229/1 234/1 235/3 237/1 240/1 245/3 250/4 251/1 252/1 255/1 255/2 259/1 259/2 259/3 260/1 260/2 260/4 260/5 260/6 104,715 183,138 233,329 217,058 145,782 187,388 85,263 156,977 100,342 112,938 93,668 76,611 81,241 95,960 87,078 71,386 234,904 137,139 154,825 88,803 90,435 87,206 613,447 1,191,778 1,395,824 1,395,876 647,749 1,187,123 470,188 Substructure Superstructure Ruppes

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

212964 222595 227462 228087 233214 234859 236259 239322 244803 249990 250350 251630 254000 254750 258170 258380 258590 259015 259230 259580 259685 259870

455,953 649,760 1,335,324 1,188,107 556,737 676,088 413,807 565,880 365,057 393,973 416,105 286,231 331,915 395,253 139,117 230,832 1,015,141 423,335 1,016,838 304,129 324,676 326,470

1,382,460 2,084,142 1,696,710 1,690,820 1,494,203 2,086,432 1,169,230 1,385,178 1,482,814 1,500,684 2,087,088 1,377,954 1,382,054 1,689,338 1,367,871 1,368,238 2,813,056 2,311,053 1,719,776 1,694,206 1,704,987 1,489,713

2,556,575 4,108,818 4,661,187 4,491,861 2,844,471 4,137,031 2,138,488 2,722,252 2,595,898 3,002,973 3,988,906 2,640,276 2,695,328 3,133,305 2,175,567 2,281,333 6,655,776 4,181,691 4,287,263 3,022,390 3,066,604 2,578,787

614,217 647,685 995,378 1,392,045 899,480 900,118 952,754 581,501 610,877 2,592,675 1,310,164 1,395,824 935,252 946,506 675,398

23 24 25 26

263570 263955 264876 265310

264/1 264/2 265/1 266/1

81,385 72,267 77,095 79,820

613,630 578,710 615,637 946,740

332,993 191,444 286,714 502,306

1,380,474 1,366,111 1,374,327 1,704,302


Total-

2,408,482 2,208,532 2,353,773 3,233,168 84,170,735

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of work : 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (Total Length = 57.50 km) in Sonitpur district in the state of Assam

Abstract of Cost for ROB

Sl. No. 1 2 3 4

Description of Items ROB No. 222/1 ROB No. 227/1 ROB No. 238/2 ROB No. 243/1 Rs. Rs. Rs. Rs. Total Rs.

Amount (Rs.) 41119979.45 39259966.47 39259966.47 39259966.47 158899879.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Annexure-I
Analysis of Rate for Hand Rail
Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 11611979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only

DETAILS OF COST FOR 6.75M


Materials 1. MS plates: 1*6*0.14*0.15*0.01*7850=9.89kg ( base plate) 1*6*0.14*0.15*0.01*7850=9.89kg (template) 1*6*0.14*0.35*0.016*7850=36.93kg (vertical plate) Total= 56.71 kg+10% wastage=62.38 kg 2. Fastener: MS bar 16mm 1*2*6*0.70*1.578 kg/m= Total= 13.26 kg+10% wastage=14.56 kg 3. MS nuts and washer: 4*6=24 nos @ 0.125 kg=3.00 kg 4. G.I. Pipe 65mm NB heavy duty 5. Welding ( base plate with verticle plate) 1*2*14.00=25.00 cm Quantity for 6 sets=28*6=168.00cm 6. Labour for cutting and errection charges i. Black smith ii. Bandhani iii. Beldar 7. Galvanishing: 1.5 sqm Quantity Unit Rate (in Rs.) Amount (in Rs.)

62.38

Kg

55.00

3430.90

14.59

Kg

50.00

729.50

3.00 6.75 168

Kg m cm

50.00 500.00 1.00

150.00 3375.00 168.00

0.18 0.09 0.66 1.5

each each each sqm

160.00 125.00 97.00 180.00 Rs. Rs. Rs. Rs.

Add 10% overhead charges Add 10% contractor's profit Cost for 6.75m Cost for 1.00m

28.80 11.25 64.02 270.00 8227.47 822.75 9050.22 905.0217 9955.24 1474.85

Say

Rs.

1475/m

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.213/1,Ch-212964
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of foundation
of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum 2816.778 54.00 152,106.00 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or Cum equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications

135.166 191.616

6514.00 9030.00

880,471.00 1,730,293.00

14.743

73279.00

1,080,384.00

196.320

8120.00

1,594,119.00

126.221

9169.00

1,157,325.00

5/13.6

Item No. 1

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure 6/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete
in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

21.948

73343.00

1,609,708.00

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint Cum 87.140 10591.00 922,900.00

MT

6.08

77554.00

471,219.00

(i)'Providing & fixing 2 mm thick corrugated copper plate metre in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/14.4 Providing and laying Cement concrete wearing coat M30 grade including reinforcement complete as per drawing and Technical Specifications 10/8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians,constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia, 450mm long at expansion joints filled with pre moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circular No. RW/NH-33022/1/94-DO III dated June 1994 as per dimension in the approved drowing and at locations directed by the engineer,all as specified. metre

24.000

1640.00

39,360.00

24.000

558.00

13,392.00

24.000

317.00

7,608.00

24.00

17.00

408.00

152.49

12993.00

1,981,303.00

Item No. 1

Particulars/Descrption of items 2 B. M 40 grade concrete

Unit 3 metre

Total Quantity 4 35.88 35.88

Rate in Rs. 5 4170.00 1475.00

Amount (Rs.) 6 149,620.00 52,923.00

11/Analy HAND RAIL metre sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 14/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical Each specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing RM 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall Cum complete as per drawing and technical specification. (A) Granular material Cum 18/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

17.94

2044.00

36,670.00

28.80 14.40 2.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 20,394.00

53.82

160.00

8,612.00

548.26 40.00

1524.00 204.00

835,543.00 8,160.00

Item No. 1

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 21/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15

Each Each Each

4 30.00

3500.00 3400.00 298.00

13,600.00 8,940.00

Cum Cum 100.14 303.66

4333.00 7046.00 1485.00

0.00 705,587.00 450,936.00

22/15.11 Flexible Apron :Construction of flexible apron 1 m thick Cum comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at Cum cross drainage works for relatively less important works

301.00

1679.00

505,371.00

Total- 14,862,444.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Item No. 1

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Item No. 1

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Item No. 1

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

3,843,254.00

4,361,152.00

4,996,144.00

1,661,894.00

Quantity Calculation fo Br. No.213/1,Ch-212964


Sl. No. 1 Item No. 12.1
Earth work in or foundation of structures as per drawings & technical specification including setting out.

2 2 2 2 2

2.65 4.35 0.3 0.3


33.74+9.94 2

12 10.34 1.5 1.5 0.45 0.45 6 3 2.5 2 16.83

6.3 12 12 10.34 11.9 9.94 0.75 0.75 1.85 1.5 2 Total =

Unit Qty for 2Lane 3 400.68 m 1079.50 10.80 9.31 233.91 67.10 151.83 75.92 156.05 101.22 530.48 2816.78 m3 17.89 16.94 22.37 77.97 135.17 m3 m3 m
3

15 33.74 33.74 33.74 33.74 4


6.08+1.8 2

12.8

PCC M-15 c/wall Apron 2

12 15
33.74+9.94 2

9.94 1 9.94 0.15

0.15 16.94 0.15 11.9 Total=

12.8

RCC M35(open foundation)

9.94 2 2 m/wall 2 0.25 0.25 1.2

12 1.5 1.5 3

1.2 12 9.44 4.5 Total=

143.14 9.00 7.08 32.40 191.62

m3

12.40

Reinforcement in foundation 25 25 20 20 12 12 m/wall mm dia mm dia mm dia mm dia mm dia mm dia 2 47 47 66 66 10 292 100 11.92 10.86 13.2 13.2 43.88 2 32.4 Total = kg Total = MT kg kg kg kg kg kg 4322.84 1969.21 2151.11 2151.11 390.04 519.11 3240.00 14743.43 14.74 4.92 3.78 106.38 11.14 126.22

13.5

Substructure (M35) Dirt wall Abutment cap -

2 2 2 2

0.82 0.7
0.7+1.2 2 0.2+0.45 2

12 12 4.666 3

0.25

m3
3

AbutmentM/wall

0.225 m 12 m3 5.7111 Total=

13.5

Substructure (M20) PCC Wing wall1 196.32 m3 196.32

13.6

Supplying, fitting and placing TMT bar Reinforcement in substructure complete as per drawing and technical specifications

Dirt wall -

12 12

mm dia mm dia mm dia mm dia mm dia mm dia mm dia

2 2 2 2 2 2 2

6 0.95 10 1.85 7.02 32 32 m/wall

25.5 2 12.45 80 2 25.9 95 11.13 1 100 95 86

kg kg kg kg kg kg kg kg

272.00 290.49 221.33 263.11 12909.87 1473.42 5404.44 1113.00 21947.67 21.95 87.14

Abutment cap -

12 12

Abutment-

28 12 12

Total = kg Total = Tonne 8 14.1


Furnished and placing reinforcement/Prestressed cement concrete in Superstructure as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications Drainage Spouts complete as per drawing and Technical specification.

87.14 m3

14.2

6.076 MT

6.08

10

14.18

12

Nos.

24.00

11

8.22

17.94 m

35.88

12

14.7

8.97

17.94

13

14.16

17.94 m2

53.82

14

14.4

17.94

8.5

m3

152.49

15

14.9

Nos.

2.00

16

13.9

17

14.11

Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material . Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works Curtain wall complete as per drawing and Technical specification

12

4.00

5.711 m3

548.26

0.3

12.00

m3

28.80

18

14.10

0.15

12.00

m3

14.40

19

13.8

20

Nos.

40.00

20

8.51

30

Nos.

30.00

21

8.47

Nos.

4.00

22

15.11

303.66 m3

303.66

23

15.9

301

m3

301.00

24

15.10

100.14 m3 2 17.94 m

100.14 35.88

25 Analysis Rate HAND RAIL


Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc

Executive Engineer, PWD Nagaon NH Division, Nagaon

Qty for 4Lane

5633.56

270.33

383.23

29486.86 29.49

252.44

392.64

43895.33 43.90 174.28

12.15

48.00

71.76

35.88

107.64

304.98

1096.51

57.60

28.80

80

60

607.32

601.99

200.28 71.76

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.213/1,Ch-212964
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1 Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I.Ordinary Soil B.Mechanical means (ii) With dewatering Cum (i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (P) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum 4/12.40 Supplying, fitting and placing uncoated HYSD reinforcement in foundation complete as per drawing and Technical Specification (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure 5/13.5 Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Unit 3 Total Quantity 4 Rate in Rs. 5 Amount (Rs.) 6

115.34 111.09

356.00 573.00

41,062.00 63,653.00

191.86

54.00

10,361.00

5.22 34.79

6514.00 9030.00

33,994.00 314,154.00

3.48

73279.00

254,938.00

2 3 Case II : With Batching plant, Transit Mixer and concrete Cum Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure 7/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Cum

Item No. 1

Particulars/Descrption of items

Unit

Total Quantity 4 27.63

Rate in Amount (Rs.) Rs. 5 6 9169.00 253,306.00

2.76

73343.00

202,647.00

26.98

10591.00

285,724.00

tonne

2.16

77554.00

167,381.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

Item Particulars/Descrption of items No. 1 2 10/8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians,constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia, 450mm long at expansion joints filled with pre moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circular No. RW/NH-33022/1/94-DO III dated June 1994 as per dimension in the approved drowing and at locations directed by the engineer,all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.1 Reinforced cement concrete approach slab including 1 reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

35.88 17.94

4170.00 2044.00

149,620.00 36,670.00

Cum

27.60 27.60 2.00 24.00

12025.00 5498.00 10197.00 204.00

331,890.00 151,745.00 20,394.00 4,896.00

13/14.1 PCC M15 grade levelling course below approach slab Cum 0 complete as per drawing and technical specification. 14/14.9 Drainage Spouts complete as per drawing and Technical Each specification. 15/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Each 17/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.

4.00 10.00

3400.00 298.00

13,600.00 2,980.00

Item Particulars/Descrption of items No. 1 2 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
19/16.17 Replacement of Expansion Joints complete as per drawings.

Unit 3 Sqm

Total Quantity 4 74.55

Rate in Rs. 5 78.00

Amount (Rs.) 6 5,815.00

metre

17.00 84.49

3628.00 59.00

61,676.00 4,985.00

20/16.2 Removal of existing asphaltic wearing coat comprising of Sqm

50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface. 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a) 12 mm dia re-bar fastners 25% of 99 b)16 mm dia re-bar fastners 25% of 99 C) 20 mm dia re-bar fastners 25% of 99 d) 25 mm dia re-bar fastners 25% of 99

Sqm

26.62

614.00

16,343.00

Each

Each Each Each Each

24.72 24.72 24.72 24.72

500.00 700.00 750.00 800.00

12,359.00 17,302.00 18,538.00 19,774.00

Total- 2,556,575.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation fo Br. No.213/1,Ch-212964


Sl.N Item o. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 Wing Wall2
(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 0.9 Rail2 2 0.2 0.175 Kerb2 0.5 0.2 Slab1 0.82 9.4 Dirt wall2 0.82 0.25 Abut/Pier2 0.7+1.0 3.95 Raft-

Unit Qty for 2-Lane 57.67 Cm 10 14.915 17.94 3.95 3.95 4.891 Cm Cm Cm Cm Cm Cm 115.34 1.24 2.09 3.59 30.45 1.62 32.84 39.26 111.09 57.46 134.40

2 9.94

3.95

1 Cm Total= Cm 1.65 4 m3 m3

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

9.95 3.5

3.5 4.8

Total= m3 3 12.8 PCC M159.94 3.5 0.15 m3 Total= 1

191.86 5.22 5.22 34.79

12.8 RCC M35 (open


foundation)-

9.94

3.5

12.4 Reinforcement in foundation-

34.79

13.5 Substructure(M35)-

2 2

6.7+1.0 2 0.25

3.15 3.5

Total= 34.79 100 kg 3479.00 Total= kg 3479.00 3.5 Total= Tonne 3 26.19 4.891 m 0.82 m3 Total= m3 1.435 27.63

13.6 Reinforcement in Substructure-

27.63

100 Kg 2763.00 2763.00 Total= Kg Total= Tonne 2.76 0.82 Total= 80 Total= Total= 2.00 12.00 12.00 12.00 12.00 0.3 26.978 26.978 2158.24 2158.24 Tonne 2.16 Nos. 2.00 m m3 Kg Kg Nos. Nos. Nos. Nos. 3 m 24.00 24.00 24.00 24.00 27.60
3

14.1 Superstructure RCC (M25)1 3.5 9.4 26.978

14.2 Reinforcement in Superstructure-

10 11

14.9 Drainage Spouts complete as per


drawing and Technical specification.

1 2 2 2 2 4

14.18 Filler joint Providing & fixing 20


mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

12

14.10 PCC M15 grade levelling course


below approach slab complete as per drawing and technical specification

11.5

Sl.N Item o. No. 13 14.11 Reinforced cement concrete


approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm.

11.5

0.3

Unit Qty for 2-Lane 3 27.60 m

14

17.94 m

17.94

15

8.22 Reinforced Cement Concrete Crash


Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete.

17.94 m

35.88

16

16.1 Removal of existing cement


concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

7.5

9.94

74.55

17 18

16.17 Replacement of Expansion Joints 16.2


complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studds,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm),90mm height (frombottom of shank to the top of stud)with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

2.00 8.5

8.5 9.94

metre metre

17.00 84.49

19

13.8

12

Nos.

24.00

20

8.47

Nos.

4.00

21

8.51

10

Nos.

10.00

22

16.28

0.82 2
0.7+1.0 2

2 4.891 1.8

0.25

sqm sqm sqm

0.41 8.31 17.89 26.62

9.94
Total=

Sl.N Item o. No. 23 16.53 Providing, placing and fixing in


position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

59.321 0.6

Unit Qty for 2-Lane Each 99

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.223/4,Ch-222595
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantit 4

Rate in Rs. 5

Amount (Rs.) 6

197.12 197.14

356.00 573.00

70,175.00 112,963.00

2/12.1 Excavation for Structures (Earth work in excavation of

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Cum 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or Cum equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete Cum pump 4/12.40 Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications

317.72

54.00

17,157.00

10.16 67.76

6514.00 9030.00

66,209.00 611,873.00

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 5/13.5 Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m

6.78

73279.00

496,539.00

2 3 Case II : With Batching plant, Transit Mixer and Cum concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

Item No. 1

Particulars/Descrption of items

Unit

Total Quantit 4 39.37

Rate in Rs. 5 9169.00

Amount (Rs.) 6 361,008.00

Tonne

3.94

73343.00

288,752.00

Cum

53.96

10591.00

571,448.00

tonne

4.32

77554.00

334,761.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

Item No. 1

Particulars/Descrption of items 2

Unit 3

Total Quantit 4

Rate in Rs. 5

Amount (Rs.) 6

10/8.22 Reinforced Cement Concrete Crash Barrier (Provision

of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians,constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia, 450mm long at expansion joints filled with pre moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circular No. RW/NH-33022/1/94-DO III dated June 1994 as per dimension in the approved drowing and at locations directed by the engineer,all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
14/14.9 Drainage

metre metre

54.72 27.36

4170.00 2044.00

228,183.00 55,924.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Spouts complete as per drawing and Each Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
16/8.47 Providing Sparkle Solar Road Studs, manufactured by

4.00 56.00

10197.00 204.00

40,788.00 11,424.00

Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 17/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.

4.00 18.00

3500.00 3400.00 298.00

13,600.00 5,364.00

Item No. 1

Particulars/Descrption of items 2 including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

Unit 3 Sqm

18/16.1 Removal of existing cement concrete wearing coat

Total Quantit 4 145.20

Rate in Rs. 5 78.00

Amount (Rs.) 6 11,326.00

19/16.17 Replacement of Expansion Joints complete as per drawings. 20/16.2 Removal of existing asphaltic wearing coat comprising

metre Sqm

25.50 164.56

3628.00 59.00

92,514.00 9,710.00

of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. (a)12 mm dia re-bar fastners 25% of 171 (b)16 mm dia re-bar fastners 25% of 171 (C) 20 mm dia re-bar fastners 25% of 171 (d)25 mm dia re-bar fastners 25% of 171

27.34 Sqm Each

614.00

16,790.00

Each Each Each Each

42.74 42.74 42.74 42.74

500.00 700.00 750.00 800.00

Total-

21,368.00 29,915.00 32,052.00 34,188.00 4,108,818.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br. No.223/4,Ch-222595


Sl. No. 1 Item No. 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20. Wing Wall2
(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab2 0.82 Dirt wall2 0.82 Abut/Pier2 0.7+1.0

Unit Qty for 2Lane 98.56 15 23.235 27.36 3.95 3.95 4.461 Cm Cm Cm Cm Cm Cm Cm 197.12 1.86 3.25 5.47 60.89 1.62 29.96 17.62 76.47 197.14 146.36 171.36 317.72 10.16 10.16 67.76 67.76 6776.00 6776.00 6.78

0.9 0.175 0.2 9.4 0.25 3.95 3.95 3.95

1
Raft-

2 1 19.36

4.461 Cm 1 Cm Total= Cm 2.16 4.0 m3 m3

12.1 Earth work in or foundation of structures


as per drawings & technical specification including setting out.(Upto 3m)-

19.36 3.5

3.5 6.12

Total= m3 3 12.8 PCC M1519.36 3.5 0.15 m3 Total= 1 3.5 Total= 67.76 kg Total= kg Total= Tonne

12.8 RCC M35 (open foundation)-

19.36

12.40 Reinforcement in foundation-

100

13.5 Substructure(M35)2 1 2 0.7+1.0 2 1.0 0.25 3.15 4.46 3.5 100 4.461 3.15 0.82 Total= 39.37 Total= Total= m3 m3 m3 m3 Kg Kg
Tonne

23.89 14.05 1.435 39.37 3937.00 3937.00 3.94 53.956 53.956 4316.48 4316.48 4.32 4.00 36.00 36.00 36.00 36.00

13.6 Reinforcement in Substructure-

14.1 Superstructure RCC (M25)2 3.5 9.4 0.82 m3 Total= m3 80 Total= Total= 2.00 12.00 12.00 12.00 12.00 Kg Kg
Tonne

14.2 Reinforcement in Superstructure-

53.96

10 11

14.9 Drainage Spouts complete as per


drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

2.00 3 3 3 3

Nos. Nos. Nos. Nos. Nos.

Sl. Item No. No. 12 14.10 PCC M15 grade levelling course below 13
approach slab complete as per drawing and technical specification 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.

11.5

4 4

0.3 0.3

Unit Qty for 2Lane 3 27.60 m m3 27.60

11.5

14

27.36

27.36

15

27.36

54.72

16

7.5

19.36

145.20

17 18

3 8.5

8.5 19.36 metre

25.50 164.56

19

13.8 Providing weep holes in brick


mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (frombottom of shank to the top of stud)with detachable battery. 8.51 RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 16.28 Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

28

Nos.

56.00

20

Nos.

4.00

21

18

Nos.

18.00

22

0.8 2

2
0.7+1.0 2

0.25 4.461 1
Total-

sqm sqm sqm

0.40 7.58 19.36 27.34

19.36

Sl. Item No. No. 23 16.53 Providing, placing and fixing in position
Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

Unit Qty for 2Lane 102.564 Each 171 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.223/4,Ch-222595
Item No. 1 Particulars/Descrption of items Unit 3 Total Quantity 4 Rate in Rs. 5 Amount (Rs.) 6

2 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

Cum

2106.25

54.00

113,738.00

Cum

Cum Cum

291.89 380.79

6514.00 9030.00

1,901,377.00 3,438,561.00

tonne

27.80

73279.00

2,036,898.00

Cum

191.99

8120.00

1,558,959.00

Cum MT

194.55

9169.00

1,783,840.00

Item No. 1

Particulars/Descrption of items 2 (i) TMT Corrosion Resistant Steel reinforcement bar of Fe-500 N/mm2 Super Structure (CRS)

Unit 3 Tonne

Total Rate in Quantity Rs. 4 5 31.64 73343.00

Amount (Rs.) 6 2,320,393.00

6/14.1 Furnishing and Placing Reinforced/Prestressed cement


concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/14.4 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

Cum

174.280

10591.00

1,845,800.00

MT

12.15

77554.00

942,437.00

metre

24.000

1640.00

39,360.00

metre

24.000

558.00

13,392.00

metre

24.000

317.00

7,608.00

metre

24.00

17.00

408.00

232.56

12993.00

3,021,653.00

2 B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 18/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

Item No. 1

Particulars/Descrption of items

Unit 3 metre metre

Total Quantity 4 54.72 54.72

Rate in Rs. 5 4170.00 1475.00

Amount (Rs.) 6 228,183.00 80,712.00

metre

27.36

2044.00

55,924.00

Cum Cum,

28.80 14.40

12025.00 5498.00

346,320.00 79,172.00

Each

8.00

10197.00

81,576.00

RM Cum

82.08

160.00

13,133.00

Cum Each

506.98 40.00

1524.00 204.00

772,632.00 8,160.00

Item No. 1 19/8.4

Particulars/Descrption of items 2 Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)
(V) 80cmm x 45 cm rectangular

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Each

17.28

5200.00

89,856.00

20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 21/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Each Each Each

4.00 60.00

3500.00 3400.00 298.00

13,600.00 17,880.00

Cum Cum Cum

90.70 206.28

4333.00 7046.00 1485.00

0.00 639,073.00 306,326.00

Cum

256.47

1679.00

430,614.00

Total-

22,187,585.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

7,490,574.00

5,663,192.00

7,657,806.00

1,376,013.00

Quantity Calculation fo Br. No.223/4 , Ch-222595


Sl. No. 1 Item No. 12.1 Earth work or
foundation of structures as per drawings & technical specification including setting out

Unit 2 2 2 2 3.5 19.36 0.3 0.3


2

5.5 1.25 1.5 1.5 0.45 0.45 6 3 2.5 2 7.92

12 12 12 19.36 5.6 19.36 0.75 0.75 1.85 1.5 2 Total=

Qty for 2Lane 462.00 580.80 10.80 17.42 215.61 130.68 137.52 68.76 141.34 91.68 249.64 2106.25 33.95 15.70 156.75 43.56 41.93 291.89 325.25 9.00 14.15 32.40 380.79

2 30.56+19.36 15 30.56 30.56 30.56 30.56 4


6.08+1.8 2

12.8

PCC M-15 = c/wall Approach base Floor apron

12

18.86 1 1

0.15 15.7

m3
3

15 2 30.56+19.36
2

19.36 0.15

156.75 m 0.15 5.6 Total=

12.8

RCC M35(open foundation)

19.36 2 2 m/wall 2 0.25 0.25 1.2

1.4 1.5 1.5 4.5

12 12

m m

3 3

18.86 m3 3 m3 Total=

12.40 Reinforcement in foundation = 25 20 12 12 m/wall mm dia mm dia mm dia mm dia 33.00 26.8 10 2 100 120 120 430 32.4 kg kg kg kg 15277.78 7940.74 573.51 764.44 3240.00 27796.47 27.80 4.92 3.78 112.42 2.70 53.53 17.20 194.55 191.99

64.52 kg

Total = kg Total= Tonne 5 13.5 Substructure (M35) RCC Dirt wall =


Abutment cap =

2 2 2

0.82 0.7
0.7+1.4 2

12 12 4.461 0.225 12 4.5

0.25

m3
3

Abutment = Pier cap Pier M/wall 6 13.5 Substructure (M20) PCC Wing wall

0.225 m 12 m3 12 m3 4.461 m3 5.881 m3 Total = 1 191.99 m3

1 1 2
0.2+0.45 2

13.6

Reinforcement in substuctureDirt wall = 12 12


Abutment cap =

mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia

2 2 2 2 1 1 2 2 2 2 1 1 30 80 27.3 30 m/wall 2 0.95

6 2 10 1.85 10 1.85 110 27.3 110 6.512 30 60 17.2

26.55 kg 86 13.5 86 13.5 86 kg kg kg kg kg

283.20 290.49 240.00 282.84 120.00 141.42 13866.54 1456.00 5866.67 5042.38 728.00 1600.00 1720.00 31637.54 31.64 174.28

12 12

Pier Cap

12 12

Abutment

28 12 12

6.512 kg 30 1 kg kg kg kg 1 100 kg kg

Pier

28 12 12

Total= kg Total= Tonne 8


Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. 14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

14.1

87.14 m3

6.076 MT

12.15

10

12

Nos.

24.00

11 12

13.14 Elastomeric bearing =


Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing 14.4 Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.

Cucm 2 27.36 m

0.00 54.72

8.22

13

27.36

27.36

14

27.36 m2

82.08

15

27.36

8.5

232.56

16 17

14.9 13.9

18

14.11

19 20

14.10 13.8

21

8.4

22

8.51

23

8.47

24

15.11

25

15.9

26

15.10

27 Analysis
Rate

Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall 2 and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material . Reinforced cement concrete approach 2 slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below 2 approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works Curtain wall complete as per drawing and Technical specification HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

2 12 4.00

Nos.

8.00 506.98

5.281 m3

0.3

12.00

28.80

0.15

12.00 2

4 20

14.40 40.00

Nos.

17.28 m2

17.28

60

Nos.

60.00

Nos.

4.00

206.28

206.28

256.47 m3

256.47

90.7 2

m3

90.70 54.72

27.36 m

Executive Engineer, PWD Nagaon NH Division, Nagaon

380.134 490.875

41.52 33.00

15783.15 16198.88

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.228/1,Ch-227462
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

315.52 211.17

356.00 573.00

112,326.00 121,003.00

2/12.1 Excavation for Structures (Earth work in excavation of foundation

3/12.8

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

386.49

54.00

20,871.00

Cum Cum

8.57 80.64

6514.00 9030.00

55,851.00 728,180.00

4/12.40 Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m

8.06

73279.00

590,922.00

Item No. 1

Particulars/Descrption of items

Unit 3 Cum MT

2 Case II : With Batching plant, Transit Mixer and concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification.

Total Quantity 4 80.91

Rate in Rs. 5 9169.00

Amount (Rs.) 6 741,905.00

Tonne

8.1

73343.00

593,419.00

Cum

33.67

10591.00

356,599.00

tonne

2.7

77554.00

208,900.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

(iv)'Providing and filling joint sealing compound as per metre drawings and technical specifications with coarse sand and 6% bitumen by weight. 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as B. M 40 grade concrete metre

36.00

17.00

612.00

46.72

4170.00

194,823.00

Item No.

Particulars/Descrption of items

Unit 3 metre

1 2 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per drawings. 20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned

Total Quantity 4 23.36

Rate in Rs. 5 2044.00

Amount (Rs.) 6 47,748.00

Cum Cum Each Each

27.60 27.60 4.00 40.00

12025.00 5498.00 10197.00 204.00

331,890.00 151,745.00 40,788.00 8,160.00

Each Each Each

4.00 15.00

3500.00 3400.00 298.00

13,600.00 4,470.00

Sqm

115.20

78.00

8,986.00

metre Sqm

25.50 130.56

3628.00 59.00

92,514.00 7,704.00

46.48 Sqm

614.00

28,538.00

Item No.

Particulars/Descrption of items

Unit 3 Each

1 2 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 159 b)16 mm dia re-bar fastners 25% of 159 C)20 mm dia re-bar fastners 25% of 159 d)25 mm dia re-bar fastners 25% of 159

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Each Each Each Each

39.67 39.67 39.67 39.67

500.00 700.00 750.00 800.00

19,835.00 27,769.00 29,753.00 31,736.00 Total- 4,661,187.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br. No.228/1,Ch-227462


Sl.N Item o. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20
Wing Wall(B) Prestressed/ Reinforced cement grade M-20 & above Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab2 0.65 Dirt wall2 0.25 Abut/Pier2 0.7+1.0 2

Unit

Qty for 2-Lane 315.52 1.61 2.77 4.67 38.00 1.28 56.69 33.35 72.81 211.17 214.29 172.20 386.49 8.57 8.57

2 0.9 0.175 0.2 7.4 0.65 3.95 3.95 3.95

157.76 Cm 13 19.785 23.36 3.95 3.95 8.442


Cm Cm Cm Cm Cm Cm

1
Raft-

1 15.36

8.442 Cm Cm 1.2 Total= Cm 3.95 4.0 m3 m3

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

15.5 3.5

3.5 6.15

Total= m3 3 12.8 PCC M1515.66 3.65 0.15 m3 Total=

4 5

12.8 RCC M35 (open foundation)12.4 Reinforcement in foundation-

15.36

3.5 80.64

1.5 80.64 Total= 80.64 100 kg 8064.00 Total= kg 8064.00 8.06 Total= Tonne

13.5 Substructure(M35)2 2
0.7+1.0 2

3.5 3.5 3.5

8.442

m3

50.23 29.55 1.14 80.91

1.0 0.65

8.442 m3 0.25 m3 Total= m3

13.6 Reinforcement in Substructure-

80.91

100 Kg 8091.00 Total= Kg 8091.00 Total= Tonne 8.1

14.1 Superstructure RCC (M25)2 3.5 7.4 0.65 m3 Total= m3 33.67 33.67

14.2 Reinforcement in Superstructure-

33.67

80 Kg 2693.60 Total= Kg 2693.60 Total= Tonne 2.7 2.00 Nos. 4.00

10

14.9 Drainage Spouts complete as per


drawing and Technical specification.

2.00

Sl.N Item o. No. 11 14.18 Filler joint Providing & fixing 20 mm


thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

Unit 3 3 3 3
2 11.5

12.00 12.00 12.00 12.00 0.3

Nos. Nos. Nos. Nos. m3

Qty for 2-Lane 36.00 36.00 36.00 36.00 27.60

12

14.10 PCC M15 grade levelling course


below approach slab complete as per drawing and technical specification Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

13

14.11

11.5

0.3

m3

27.60

14

14.7

23.36

23.36

15

8.22

23.36

46.72

16

16.1

7.5

15.36

115.20

17 18

16.17 Replacement of Expansion Joints


complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (frombottom of shank to the top of stud)with detachable battery.

3 8.5

8.5 15.36 metre

25.50 130.56

19

20

Nos.

40.00

20

Nos.

4.00

Sl.N Item o. No. 21 8.51 RPM: Providing relfective pavement


marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

Unit 15 Nos.

Qty for 2-Lane 15.00

22

16.28 Supplying and applying Epoxy based


bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

2
2

0.65
0.7+1.0 2

0.25 8.442 8.442 23.36

sqm sqm sqm

0.33 14.35 8.44 23.36 46.48 159

1 1

Total-

23

16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

95.208 Each 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.228-1,Ch-227462
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35

Cum

1746.96

54.00

94,336.00

Cum

Cum Cum

131.07 278.80

6514.00 9030.00

853,806.00 2,517,564.00

(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

tonne

40.94

73279.00

2,999,812.00

Cum

487.22

8120.00

3,956,227.00

Cum MT

362.38

9169.00

3,322,648.00

5/13.6

Item No. 1

Particulars/Descrption of items 2 (i) TMT Corrosion Resistant reinforcement bar of Fe-500 N/mm2 Super Structure Steel (CRS)

Unit 3 Tonne

Total Quantity 4 57.24

Rate in Rs. 5 73343.00

Amount (Rs.) 6 4,198,472.00

6/14.1 Furnishing and Placing Reinforced/Prestressed cement


concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/14.22 Strip Seal Expansion Joint (Providing and laying of a strip
seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation).

Cum

84.52

10591.00

895,152.00

MT

16.51

77554.00

1,280,417.00

metre

1640.00

0.00

metre

558.00

0.00

metre

317.00

0.00

metre

17.00

0.00

metre

24.00

11804.00

283,296.00

10/13.14 Supplying, fitting and fixing in position true to line and level
elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.

Cucm

105600.00

1.02

107,712.00

11/14.4 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications

197.54

12993.00

2,566,638.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 12/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 13/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 14/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 15/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 16/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 17/14.9 Drainage Spouts complete as per drawing and Technical specification. 18/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 19/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

46.48 46.48

4170.00 1475.00

193,822.00 68,558.00

metre

23.24

2044.00

47,503.00

Cum Cum,

28.80 14.40

12025.00 5498.00

346,320.00 79,172.00

Each

4.00

10197.00

40,788.00

RM

69.72

160.00

11,156.00

Cum

1084.03

1524.00

1,652,065.00

Item No.

Particulars/Descrption of items

Unit 3 Each

1 2 20/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 21/8.4 Retro reflectorised Traffic sign:
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)

Total Quantity 4 40.00

Rate in Rs. 5 204.00

Amount (Rs.) 6 8,160.00

(V) 80cmm x 45 cm rectangular

23/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 24/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 25/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 26/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Each Each

17.28 60.00

5200.00 298.00

89,856.00 17,880.00

Cum Cum Cum

93.90 213.57

4333.00 7046.00 1485.00

0.00 661,620.00 317,152.00

Cum

275.86

1679.00

463,169.00

Total- 27,073,301.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br. No.228/1 , Ch-227462


Sl.N Item o. no. 1 12.1 Earth work or
foundation of structures as per drawings & technical specification including setting out

Unit 2 2 16.3
31.64+15.24 2

8 0.45 0.45 6 3 2.5 2


6.08+1.8 2

2.16 9.5 15.24 0.75 0.75 1.85 1.5 2 Total =

Qty for 2Lane 563.33 200.41 102.87 142.38 71.19 146.34 94.92 425.52 1746.96

15 31.64 31.64 31.64 31.64 13.5

12.8 PCC M-15 =

2 2

16.3 15
31.64+15.24 2

8 15.24 0.15

0.15 0.15 8.2 Total =

m3 m3 3 m

39.12 34.29 57.66 131.07

12.8 RCC M35(open


foundation)

2 m/wall

16

7.7 1.2

1 4.5

m3 m3

246.40 32.40 278.80

2 3 Total R.C.C.M35

12.40 Reinforcement in foundation = 32 16 20 25

mm dia mm dia mm dia mm dia m/wall

2 2 2 2

2 14

160 106 77 16.8 100

Kg Kg Kg Kg 32.4 Kg Total = Kg Total = Tonne

9.8 9.8 16.8

19822.62 3283.12 12776.30 1814.81 3240.00 40936.85 40.94

13.5 Substructure RCC M-35 Dirt wall


Abutment cap

Abutment Pier cap Pier M/wall

2 2 2

1.588 0.225
1.0+1.5 2

12 12 8.974 0.225 12 3

0.3 1 12 12

m3 m3 m3

11.43 5.40 269.22 2.70 53.53 20.09 362.38

1 1 2
0.2+0.45 2

4.461 10.304 m3 Total =

13.5 Substructure PCC M20 Wing wall 13.6 Reinforcement in substuctureDirt wall 12 mm dia 2 12 mm dia 2 Abutment cap 12 12 32 mm dia 2 mm dia 2 mm dia 2

487.22 m3

487.22

2 2 6 2.6 2

4.08 12.6 2 86 112

86 11 12.8

kg kg kg kg kg

1247.57 492.80 273.07 397.51 31971.05

Abutment

11.29

Sl.N Item o. no. 12 12 mm dia 2 mm dia 2 M/wall 60 60 27.5 112 100

14.1 Furnished and placing


reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification Supplying, fitting and fixing in position true 8 to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall 2 and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material . Reinforced cement concrete approach 2 slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below 2 approach slab complete as per drawing and technical specification mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe,

Qty for 2Lane kg 2933.33 1.5 kg 17920.00 20.09 kg 2009.00 Total= kg 57244.33 Total= Tonne 57.24 84.52 m3 84.52

Unit

14.2

16.51

MT

16.51

10 13.14

50

40

6.6

Cucm 105600.00

11

8.22

23.24

46.48

12

14.7

23.24

23.24

13 14.22

12

24.00

14 14.16

23.24

m2

69.72

15

14.4

8.50

23.24

197.54

16 17

14.9 13.9

1 12 4.00

Nos.

4 1084.03

11.292 m3

18 14.11

0.3

12.00

m3

28.80

19 14.10

0.15

12.00

m3 Nos.

14.40

20

13.8 Providing weep holes in brick

20

40

Sl.N Item o. no. 21 8.4 Sign board : Retro reflectorised Traffic


sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works Curtain wall complete as per drawing and Technical specification HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

Unit 1 17.28 m
2

Qty for 2Lane 17.28

22

8.51

60

Nos.

60

23 15.11

213.57

214

24

15.9

275.86 m3

276

25 15.10 26 Analys
is Rate

1 2

93.9 23.24

m3 m

94 46.48

Executive Engineer, PWD Nagaon NH Division,

3136 19822.62

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.229/1,Ch-228087
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

286.02 201.11

356.00 573.00

101,824.00 115,234.00

2/12.1

3/12.8

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-91031999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum
coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

387.45

54.00

20,923.00

8.57 80.64

6514.00 9030.00

55,851.00 728,180.00

4/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Cum Pump.

8.06

73279.00

590,922.00

71.99

9169.00

660,110.00

Item No. 1 6/13.6

Particulars/Descrption of items

Unit

2 3 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

7.2

73343.00

527,997.00

7/14.1

33.67

10591.00

356,599.00

8/14.2

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered sealantas complete as (iv)'Providing and filling joint sealingwith compound per per drawing and technical specification. drawings and technical specifications with coarse sand and 6% bitumen by weight. 10/14.4 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete

tonne

2.7

77554.00

208,900.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

metre

46.72

4170.00

194,823.00

Item No. 1 11/14.7

12/14.11

13/14.10 14/14.9 15/13.8

16/8.47

17/8.51

18/16.1

Total Rate in Quantity Rs. 2 3 4 5 Construction of RCC railing of M30 Grade in-situ with 20 metre 23.36 2044.00 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification Cum a) With TATA make TMT CRS (Fe-500) grade rebar 27.60 12025.00 PCC M15 grade levelling course below approach slab Cum 27.60 5498.00 complete as per drawing and technical specification Drainage Spouts complete as per drawing and Technical Each 4.00 10197.00 specification Providing weep holes in brick mansonry/plain/reinforced Each 40.00 204.00 concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each 3500.00 b) Uni-directional Stud Each 4.00 3400.00 Providing relfective pavement marker with Micro prismatic Each 15.00 298.00 lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Sqm Removal of existing cement concrete wearing coat 115.20 78.00 including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) Particulars/Descrption of items Unit 25.50 130.56 3628.00 59.00

Amount (Rs.) 6 47,748.00

331,890.00 151,745.00 40,788.00 8,160.00

13,600.00 4,470.00

8,986.00

19/16.17 Replacement of Expansion Joints complete as per drawings. metre 20/16.2 Removal of existing asphaltic wearing coat comprising of Sqm 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 152

92,514.00 7,704.00

43.93 Sqm Each

614.00

26,973.00

Each

38.10

500.00

19,049.00

Item No. 1

Particulars/Descrption of items 2 b)16 mm dia re-bar fastners 25% of 152 C)20 mm dia re-bar fastners 25% of 152 d)25 mm dia re-bar fastners 25% of 152

Unit 3 Each Each Each

Total Quantity 4 38.10 38.10 38.10

Rate in Rs. 5 700.00 750.00 800.00

Amount (Rs.) 6 26,668.00 28,573.00 30,478.00 Total- 4,491,861.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br. No.229/1,Ch-228087


Sl. Item No. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 .
Wing Wall(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab2 0.65 Dirt wall2 0.25 Abut/Pier2 0.7+1.0 2

Unit

Qty for 2-Lane 286.02 1.61 2.77 4.67 38.00 1.28 50.35 29.62 72.81 201.11 227.85 159.60 387.45 8.57 8.57 80.64 80.64

2 0.9 0.175 0.2 7.4 0.65 3.95 3.95 3.95

143.01 Cm 13 19.785 23.36 3.95 3.95 7.498


Cm Cm Cm Cm Cm Cm

1
Raft-

1 15.36

7.498 Cm 1.2 Cm Total= Cm 4.2 4.0 m m3


3

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

15.5 3.5

3.5 5.7

Total= m3 3 12.8 PCC M1515.66 3.65 0.15 m3 Total= 1.5 m3 Total= m3

12.8 RCC M35 (open foundation)-

15.36

3.5

12.40 Reinforcement in foundation-

80.64

100 kg 8064.00 Total= kg 8064.00 Total= Tonne 8.06


3 7.498 m

13.5 Substructure(M35)-

2 2

0.7+1.0 2
1

3.5 3.5 3.5

44.61 26.24 1.14 71.99

0.65

7.498 m3 0.25 m3 Total= m3

13.6 Reinforcement in Substructure-

71.99

100 Kg 7199.00 Total= Kg 7199.00 Total= Tonne 7.2 0.65 m3 Total= m3 80 Total= Total= 2 Kg Kg 33.67 33.67

14.1 Superstructure RCC (M25)-

3.5

7.4

14.2 Reinforcement in Superstructure-

33.67

10 11

14.9 Drainage Spouts complete as per


drawing and Technical specification. 14.2 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

2 3 3 3

2693.60 2693.60 Tonne 2.7 Nos. 4.00 36.00 36.00 36.00

12.00 Nos. 12.00 Nos. 12.00 Nos.

11 14.2 Filler joint Providing & fixing 20 mm Sl. Item thick compressible fibre board in No. No. expansion joint complete as per
drawing & Technical Specification.

Unit 3 4 4 12.00 Nos. 0.3 m3 0.3 m3

12 14.10 PCC M15 grade levelling course 13 14.1


below approach slab complete as per drawing and technical specification Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

11.5

Qty for 2-Lane 36.00 27.60 27.60

11.5

14

14.7

23.36 m

23.36

15

8.22

23.36 m

46.72

16

16.1

7.5

15.36

115.20

17 16.17 Replacement of Expansion Joints 18 16.2


complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (frombottom of shank to the top of RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

3 8.5

8.5

metre

25.50 130.56

15.36 metre

19

13.8

20

Nos.

40.00

20

8.47

Nos.

4.00

21

8.51

15

Nos.

15.00

22

16.3 Supplying and applying Epoxy based


bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

2
2

0.65
0.7+1.0 2

0.25 sqm 7.498 sqm 7.498 sqm 23.36 sqm Total-

0.33 12.75 7.50 23.36 43.93

1 1

Sl. Item No. No. 23 16.53 Providing, placing and fixing in


position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

Unit 91.432 Each 0.6

Qty for 2-Lane 152

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.229-1,Ch-228087
Item No. 1 Particulars/Descrption of items 2 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

Cum

1836.57

54.00

99,175.00

Cum

Cum Cum

283.98 262.80

6514.00 9030.00

1,849,825.00 2,373,084.00

tonne

22.85

73279.00

1,674,257.00

Cum

565.76

8120.00

4,593,972.00

Cum MT

252.55

9169.00

2,315,642.00

Item No. 1

Particulars/Descrption of items 2 (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Unit 3 Tonne

Total Quantity 4 48.16

Rate in Rs. 5 73343.00

Amount (Rs.) 6 3,532,267.00

6/14.1 Furnishing and Placing Reinforced/Prestressed cement

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/14.22 Strip Seal Expansion Joint (Providing and laying of a strip
seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation). 10/13.14 Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.

Cum

84.32

10591.00

893,034.00

MT

16.51

77554.00

1,280,417.00

metre

1640.00

0.00

metre

558.00

0.00

metre

317.00

0.00

metre

17.00

0.00

metre

24.00

11804.00

283,296.00

Cucm

105600.00

1.02

107,712.00

Item No. 1 11/8.4

Particulars/Descrption of items 2
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

12/14.4 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications 13/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete
14/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier

Each m3

17.28 197.54

5200.00 12993.00

89,856.00 2,566,638.00

metre metre

46.48 46.48

4170.00 1475.00

193,822.00 68,558.00

15/14.7

16/14.11

16/14.10 17/14.9

consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- incharge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Drainage Spouts complete as per drawing and Technical specification.

metre

23.24

2044.00

47,503.00

Cum Cum, Each

28.80 14.40 4.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 40,788.00

Item No. 1

Particulars/Descrption of items 2 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

18/14.16 Painting on concrete surface (Providing and applying

RM

69.72

160.00

11,156.00

19/13.9

20/13.8

Cum Each

867.84 60.00

1524.00 204.00

1,322,589.00 12,240.00

21/8.47

22/8.51

Each Each Each

60.00

3500.00 3400.00 298.00

0.00 17,880.00

23/15.10

24/15.11

Cum Cum Cum

101.92 231.79

4333.00 7046.00 1485.00

0.00 718,129.00 344,209.00

25/15.9

Cum

315.94

1679.00

530,464.00

Total- 25,392,005.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

5,996,341.00

10,441,881.00

7,360,981.00

1,592,802.00

Quantity Calculation fo Br. No.229/1, Ch- 228087


Sl. Item No. no. 1 12.1 Earth work or
foundation of structures as per drawings & technical specification including setting out

Unit 2 2 16.3 34.34+15. 24 2 15 34.34


34.34

7.5 0.45 0.45 6 3 2.5 2 13.5

2.46 9.55 15.24 0.75 0.75 1.85 1.5 2

Qty for 2Lane 601.47 213.07 102.87 154.53 77.27 158.82 103.02 425.52

34.34 34.34 4 6.08+1.8 2

Total = 2 12.8 PCC M-15 = 2 2 16.3 15 34.34+15. 24 2 7.5 15.24 0.15 0.15 0.15 9.55 m m m
3 3 3

1836.57 36.68 34.29 71.02 141.99 230.40 32.40 262.80

Total= 3 12.8
RCC M35(open foundation)

2 m/wall 2

16 3

7.2 1.2

1 4.5 Total=

m3 m3

4 12.40 Reinforcement in foundation = 32 16 16 m/wall mm dia mm dia mm dia 2 2 2 80 160 60 8.8 8.8 16.5 100 2 32.4 Total = 5 13.5 Substructure (M35) Dirt wall =
Abutment cap =

kg kg kg kg kg

8899.95 4449.98 6257.78 3240.00 22847.70 22.85 11.43 5.40 216.90 18.82 252.55

Total = Tonne 2 2 2 2 1.588 0.225 1.0+1.5 2 9.65 12 12 12 0.2+0.45 2 0.3 1 7.23 3 Total= 6 13.5 Substructure (M20) PCC Wing wall7 13.6 Reinforcement in substuctureDirt wall = 12 12 mm dia mm dia 2 2 2 2 4.08 12.6 86 11 kg kg 1 565.76 m3 m3 m m
3 3

Abutment = M/wall

m3

565.76

1247.57 492.80

Sl. Item No. no. Abutment cap = 12 12 Abutment = 32 12 12 mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 6 2.6 2 48 48 m/wall 2 86 112 27.5 112 18.82 1.5 100 9.6 12.8

Unit

Qty for 2Lane 273.07 397.51 0.00 27185.30 2346.67 14336.00 1882.00 48160.92 48.16 84.32

kg kg kg kg kg kg

Total = kg Total = Tonne 8 14.1


Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (PartII) section IX and clause 2005 of MoRTH specifications complete including all accessories. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification.

84.32 m

14.2

16.51

MT

16.51

11 13.1

50

40

6.6

Cucm

105600.00

12 8.22

23.24 m

46.48

13 14.7

23.24 m

23.24

14 14.2

12

24.00

15 14.2

23.24 m2

69.72

16 14.4

8.50

23.24 m3

197.54

17 14.9

Nos.

Sl. Item No. no. 18 13.9 Back filling behind Abutment ,Wing
wall and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material . 14.1 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification.

Unit 2 12 4.00 9.04 m


3

Qty for 2Lane 867.84

19

0.3

12.00

28.80

20 14.10 PCC M15 grade levelling course


below approach slab complete as per drawing and technical specification 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 8.4 Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3

0.15

12.00

14.40

21

30

Nos.

60.00

22

30

Nos.

60.00

23

17.28 m2

17.28

24 15.1 Stone apron Flexible Apron


:Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

231.79 m3

231.79

25 15.9

315.94 m3

315.94

26 15.10 27
Rate analysi s

1 2

101.92 m3 23.24 m

101.92 46.48

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.234/1,Ch-233214 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

228.38 112.53

356.00 573.00

81,304.00 64,478.00

2/12.1 Excavation for Structures (Earth work in excavation of

3/12.8

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

198.39

54.00

10,714.00

Cum Cum

1.64 38.29

6514.00 9030.00

10,690.00 345,759.00

4/12.40 Reinforcement in Foundation: Supplying, fitting and placing


un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35

tonne

3.83

73279.00

280,586.00

Item No. 1

Particulars/Descrption of items

Unit

2 3 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper metre plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per metre drawings and technical specifications with coarse sand and 6% bitumen by weight.

Total Quantity 4 33.73

Rate in Rs. 5 9169.00

Amount (Rs.) 6 309,314.00

3.37

73343.00

247,423.00

32.76

10591.00

346,962.00

2.62

77554.00

203,254.00

24.00

1640.00

39,360.00

24.00

558.00

13,392.00

24.00

317.00

7,608.00

24.00

17.00

408.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

37.88 18.94

4170.00 2044.00

157,960.00 38,714.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

2.00 24.00

10197.00 204.00

20,394.00 4,896.00

Each Each Each

4.00 12.00

3500.00 3400.00 298.00

13,600.00 3,576.00

Item No. 1
18/16.1

Particulars/Descrption of items 2 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

Unit 3 Sqm

Total Quantity 4 82.05

Rate in Rs. 5 78.00

Amount (Rs.) 6 6,400.00

19/16.17 Replacement of Expansion Joints complete as per drawings.

metre Sqm

17.00 92.99

3628.00 59.00

61,676.00 5,487.00

Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 109 b)16 mm dia re-bar fastners 25% of 109 C)20 mm dia re-bar fastners 25% of 109 d)25 mm dia re-bar fastners 25% of 109

20/16.2

19.48 Sqm

614.00

11,964.00

Each Each Each Each

27.24 27.24 27.24 27.24

500.00 700.00 750.00 800.00

Total-

13,621.00 19,070.00 20,432.00 21,794.00 2,844,471.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br. No.234/1,Ch-233214 m


Sl. Item No. No Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20. 1 2.4
Wing Wall(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab1 0.9 Dirt wall2 0.9 Abut/Pier2 0.7+1.0 Raft-

Unit Qty for 2Lane 2 114.19 11 15.915 18.94 3.95 3.95 3.453 3.95 Total= Cum 2.11 4.0 m3 3 m 228.38 1.36 2.23 3.79 36.97 1.78 23.19 43.21 112.53 80.79 117.60 198.39 1.64 1.64 38.29 38.29 3829.00 3829.00 3.83 32.16 1.58 33.73 3373.50 3373.50 3.37 32.76 32.76 2620.80 2620.80 2.62 2.00 24.00 24.00 24.00 24.00 27.60

0.9 0.175 0.2 10.4 0.25 3.95 1

2 10.94

12.1

Earth work in or foundation of structures as per drawings & technical specification including setting out.(Upto 3m)-

10.94 3.5

3.5 4.2

Total= m3 3 12.8
PCC M15-

10.94

0.15 m3 Total= 3.5 m3 Total= m3 100 kg Total= kg Total= Tonne 5.405 m3

12.8

RCC M35 (open foundation)-

10.94

12.40

Reinforcement in foundation-

38.29

13.5

Substructure(M35)-

2 2

0.7+1.0 2 0.25

3.5 3.5

0.9 m3 Total= m3 100 Total= Total= 0.9 Total= 80 Total= Total= 2 12 12 12 12 0.3 Kg Kg
Tonne

13.6

Reinforcement in Substructure-

33.735

14.1

Superstructure RCC (M25)-

3.5

10.4

m 3 m Kg Kg
Tonne

14.2

Reinforcement in Superstructure-

32.76

10 11

14.9 14.18

Drainage Spouts complete as per drawing and Technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 2 11.5

1 2 2 2 2 4

Nos. Nos. Nos. Nos. Nos. m


3

12

14.10

Sl. Item No. No 13 14.11 Reinforced cement concrete


approach slab including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) Replacement of Expansion Joints complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud)with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

11.5

0.3

Unit Qty for 2Lane 3 27.60 m

14

14.7

18.94

18.94

15

8.22

18.94

37.88

16

16.1

7.5

10.94

82.05

17 18

16.17 16.2

2 8.5

8.5 10.94 metre

17.00 92.99

19

13.8

12

Nos.

24.00

20

8.47

Nos.

4.00

21

8.51

12

Nos.

12.00

22

16.28

0.9
2

2
0.7+1.0 2

0.25 5.405 10.94

sqm sqm sqm


Total-

0.45 9.19 9.85 19.48

0.9

Sl. Item No. No 16.53 Providing, placing and fixing in 23


position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

Unit Qty for 2Lane 65.38 0.6 Each 109

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.234-1,Ch-233214
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork.

2509.74

54.00

135,527.00

(p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

Cum Cum

215.21 246.53

6514.00 9030.00

1,401,862.00 2,226,121.00

tonne

15.94

73279.00

1,167,906.00

Cum

394.25

8120.00

3,201,310.00

Cum MT

296.40

9169.00

2,717,720.00

Item No. 1

Particulars/Descrption of items

Unit

2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

38.92

73343.00

2,854,613.00

6/14.1 Furnishing and Placing Reinforced/Prestressed cement

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) MT reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)

106.40

10591.00

1,126,883.00

7.05

77554.00

546,524.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

(V) 80cmm x 45 cm rectangular

Each

17.28

5200.00

89,856.00

Item No. 1
10/14.4

Particulars/Descrption of items

Unit

2 3 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 12/Analy HAND RAIL metre sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ metre with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
14/14.11 Reinforced cement concrete approach slab including

Total Rate in Quantity Rs. 4 5 160.99 12993.00

Amount (Rs.) 6 2,091,744.00

37.88 37.88

4170.00 1475.00

157,960.00 55,873.00

18.94

2044.00

38,714.00

reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 15/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification Drainage Spouts complete as per drawing and Each Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ (B) For RCC Railing RM 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum
16/14.9

28.80 14.40

12025.00 5498.00

346,320.00 79,172.00

2.00

10197.00

20,394.00

56.82

160.00

9,092.00

453.96

1524.00

691,836.00

Item No. 1
19/13.8

Particulars/Descrption of items

Unit

2 3 Providing weep holes in brick Each mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).

Total Quantity 4 40.00

Rate in Rs. 5 204.00

Amount (Rs.) 6 8,160.00

20/8.47

a) Bi-directional Stud Each b) Uni-directional Stud Each 21/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
22/15.10 Curtain wall complete as per drawing and Technical

4.00 30.00

3500.00 3400.00 298.00

13,600.00 8,940.00

specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Cum Cum Cum

72.12 164.03

4333.00 7046.00 1485.00

0.00 508,158.00 243,578.00

Cum

358.48

1679.00

601,880.00

Total-

20,404,511.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br. No.234/1, Ch-233214


Sl. Item No. no. 1 12.1 Earth work or
foundation of structures as per drawings & technical specification including setting

Unit

Qty for 2Lane 464.28 1197.504 10.80 10.21 105.931 73.845 109.350 54.675 112.388 72.900 297.864

2 2 2 2 2

2.65 4.4 0.3 0.3 24.3+10.94 2 15 24.3 24.3 24.3 24.3 9.45

12 11.34 1.5 1.5 0.45 0.45 6 3 2.5 2 6.08+1.8 2

7.3 12 12 11.34

m3 m3 m3 m3

6.68 m3 10.94 0.75 0.75 1.85 1.50 2 m3 m3 m3 m3 m3 m3

Total = 2509.743 2 12.8 PCC M-15 = c/wall


Apron Base

12

10.44 1 1 10.94 0.15

0.15 m3 15.7 m3 120.8 m3 0.15 m 6.68 m3 Total=


3

18.79 15.70 120.79 24.62 35.31 215.21 196.92 9.00 8.21 32.40 246.53

15 2 10.94+24.3 2

12.8 RCC M35(open


foundation)

11 2 2 2

12 0.25 0.25 4.5

1.5 1.5 1.5 1.2

m3 12 m3 10.94 m3 3 m3 Total=

m/wall

12.40 Reinforcement in foundation = 25 mm dia 20 mm dia 12 mm dia 12 mm dia m/wall

2 2

10 55 10 318 100

100 14.7 47.68 2 32.4 Total = Total = 0.9 0.225 12 3 Total=

kg kg kg kg kg kg

7716.05 3992.59 423.82 565.33 3240.00 15937.80 Tonne 15.94 m3 m3 m3 m3 5.40 3.78 273.77 13.46 296.40

13.5 Substructure (M35) Dirt wall = Abutment cap = Abutment = M/wall

2 2 2 2

12 0.7
(0.7+1.5)

6.9

0.25 12 5.185 0.2+0.45 2

13.5

Substructure (M20) PCC

Sl. Item No. no. Wing wall7 13.6 Reinforcement in substuctureDirt wall = 12 mm dia 12 mm dia Abutment cap = 12 12 32 12 12 mm dia mm dia mm dia mm dia mm dia

Unit 1 394.25 m3

Qty for 2Lane 394.25

2 2 2 2 2 2 2

1.05

6 2 10 86 2 35 120 100

26.55 kg 86 kg 13.5 kg kg 8.5

283.20 321.07 240.00 282.84

1.85 120 27.3 35 m/wall

Abutment =

kg 25789.63 kg 1698.67 1.2 kg 8960.00 13.46 kg 1346.00 Total = kg 38921.41 Total = Tonne 38.92 106.40 m3 106.40

14.1 Furnished and placing


reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and

14.2

7.047 MT

7.05

10

14.2

12

Nos.

24.00

11

8.22

18.94 m

37.88

12

14.7

18.94 m

18.94

13

14.2

18.94 m2 8.5 m3

56.82

14

14.4

18.94

160.99

15 16

14.9 13.9

1 2 12 3.00

Nos.

2 453.96

6.305 m3

17

14.1

0.3

12.00

m3

28.80

Sl. Item No. no. 18 14.10 PCC M15 grade levelling course below 19
approach slab complete as per drawing and technical specification 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 dia AC pipe, Providing relfective pavement marker 8.51 mm with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

Unit 2 0.15 12.00 2 4 20 m3 Nos.

Qty for 2Lane 14.40 40

20

30

Nos.

30

21

8.4

17.28

17.28

22

8.47

Nos.

23

15.1

164

m3

164.025

24

15.9

358.5 m3

358.475

25 15.10 26 Analys
is Rate

1 2

72.12 m3 18.94 m

72.12 37.88

Executive Engineer, PWD Nagaon NH Division, Nagaon

380.1336 490.875

12.44 4728.862 10.00 4908.750

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.235/3,Ch-234859
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

204.56 199.94

356.00 573.00

72,824.00 114,564.00

3/12.8

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete Cum pump

231.52

54.00

12,502.00

10.16 67.76

6514.00 9030.00

66,209.00 611,873.00

4/12.40 Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35

6.78

73279.00

496,539.00

Item No. 1

Particulars/Descrption of items

Unit

6/13.6

2 3 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications

Total Quantity 4 41.60

Rate in Rs. 5 9169.00

Amount (Rs.) 6 381,469.00

4.02

73343.00

294,619.00

7/14.1

53.96

10591.00

571,448.00

8/14.2

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

tonne

4.32

77554.00

334,761.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

54.72 27.36

4170.00 2044.00

228,183.00 55,924.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

14/14.9 Drainage Spouts complete as per drawing and Each Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).

4.00 60.00

10197.00 204.00

40,788.00 12,240.00

a) Bi-directional Stud b) Uni-directional Stud

Each Each

4.00

3500.00 3400.00

13,600.00

Item No.

Total Quantity 1 2 3 4 17/8.51 Providing relfective pavement marker with Micro Each 18.00 prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat Sqm 145.20 including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per drawings. metre 25.50 Particulars/Descrption of items Unit Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 173 b)16 mm dia re-bar fastners 25% of 173 C)20 mm dia re-bar fastners 25% of 173 d)25 mm dia re-bar fastners 25% of 173
20/16.2

Rate in Rs. 5 298.00

Amount (Rs.) 6 5,364.00

78.00

11,326.00

3628.00 59.00

92,514.00 9,710.00

Sqm

164.56

27.79 Sqm

614.00

17,063.00

Each Each Each Each

43.17 43.17 43.17 43.17

500.00 700.00 750.00 800.00

Total-

21,586.00 30,221.00 32,379.00 34,538.00 4,137,031.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br. No.235/3,Ch-234859


Sl. No. 1 Item No. 2.4
Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 Wing Wall2 102.28 (B) Prestressed/ Reinforced cement grade M-20 & above Post 2 0.28 0.25 0.9 15 Rail2 2 0.2 0.175 23.235 Kerb2 0.5 0.2 27.36 Slab2 9.4 3.95 0.82 Dirt wall2 0.82 0.25 3.95 Abut/Pier2 4.723 0.7+1.0 3.95

Unit

Qty for 2-Lane 204.56 1.86 3.25 5.47 60.89 1.62 31.71 18.66 76.47 199.94 69.12 162.40 231.52 10.16 10.16 67.76 67.76 6776.00 6776.00 6.8 25.29 14.88 1.435 41.60 4017.00 4017.00 4.02 53.96 53.96 4316.48 4316.48 4.32 4.00 36.00 36.00 36.00 36.00

Cm Cm Cm Cm Cm Cm Cm

1
Raft-

2 1 19.36

3.95 3.95

4.723 Cm 1 Cm Total= Cm 1.02 4.0 m m3


3

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

19.36 3.5

3.5 5.8

12.8 PCC M15-

19.36

3.5

Total= m3 0.15 m3 Total= 3.5 Total= 67.76 kg Total= kg Total= Tonne 4.723 m3

4 5

12.8 RCC M35 (open foundation)12.40 Reinforcement in foundation-

19.36

1.0 100

13.5 Substructure(M35)-

2 1 2

0.7+1.0 2 1.00 0.25

3.15 4.723 3.5 40.17

13.6 Reinforcement in Substructure-

3.15 m3 0.82 Total= m3 100 Kg


Total= Kg

14.1 Superstructure RCC (M25)-

3.5

9.4

Total= Tonne 0.82 m3 Total= m3 80 Kg

14.2 Reinforcement in Superstructure-

53.956

Total= Kg Total= Tonne

10 11

14.9 Drainage Spouts complete as


per drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

2 3 3 3 3

2 12 12 12 12

Nos. Nos. Nos. Nos. Nos.

Sl. Item No. No. 12 14.10 PCC M15 grade levelling


course below approach slab complete as per drawing and technical specification 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud)with detachable battery.

Unit 2 11.5 4 0.3 m


3

Qty for 2-Lane 27.60

13

11.5

0.3

27.60

14

27.36

27.36

15

27.36

54.72

16

7.5

19.36

145.20

17 18

3 8.5

8.5 19.36 Sqm

25.50 164.56

19

30

Nos.

60.00

20

Nos.

4.00

Sl. No. 21

Item No. 8.51 RPM: Providing relfective


pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 16.28 Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

Unit 18 Nos.

Qty for 2-Lane 18.00

22

0.8 2

2 0.7+1.0 2 19.36

0.25 4.723 1

sqm sqm sqm

0.40 8.03 19.36

Total-

23

16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

103.612 Each 0.6

27.79 173

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.235-3,Ch-234859
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of foundation
of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Rate in Quantity Rs. 4 5

Amount (Rs.) 6

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum

2044.56

54.00

110,406.00

137.73 398.88

6514.00 9030.00

897,183.00 3,601,887.00

3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Cum Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure

26.30

73279.00

1,926,889.00

201.51

8120.00

1,636,262.00

196.10

9169.00

1,798,060.00

32.19

73343.00

2,360,580.00

Item Particulars/Descrption of items Unit No. 1 2 3 6/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete in
super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Total Rate in Quantity Rs. 4 5

Amount (Rs.) 6

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4 Retro reflectorised Traffic sign:
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular

Cum

174.28 10591.00

1,845,800.00

MT

12.15

77554.00

942,437.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

9/14.4 Providing and laying Cement concrete wearing coat M-30 m3 grade including reinforcement complete as per drawing and Technical Specifications

17.28 5200.00 232.56 12993.00

89,856.00 3,021,653.00

Item Particulars/Descrption of items Unit No. 1 2 3 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineerin-charge. Management shall be made for the length of the 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) metre metre

Total Rate in Quantity Rs. 4 5

Amount (Rs.) 6

54.72 54.72

4170.00 1475.00

228,183.00 80,712.00

metre

27.36

2044.00

55,924.00

Cum Cum, Each

28.80 14.40 8.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 81,576.00

(B) For RCC Railing RM 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum 18/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

82.08

160.00

13,133.00

488.93 40.00

1524.00 204.00

745,127.00 8,160.00

Item Particulars/Descrption of items No. 1 2 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 21/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Unit 3

Total Rate in Quantity Rs. 4 5

Amount (Rs.) 6

Each Each Each

4.00 60.00

3500.00 3400.00 298.00

13,600.00 17,880.00

Cum Cum Cum

92.36 210.06

4333.00 7046.00 1485.00

0.00 650,769.00 311,940.00

Cum

153.40

1679.00 Total-

257,552.00 21,212,213.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br. No.235/3 Ch-234859 m


Sl. Item No. no. 1 12.1 Earth work or
foundation of structures as per drawings & technical specification including setting out

Unit

Qty for 2Lane 462.00 580.80 10.80 17.42 133.57 130.68 140.04 70.02 143.93 93.36 261.931 2044.56 0.00 33.95 15.70 43.56 44.52 137.73

2 2 2 2 2

3.5 19.36 0.3 0.3


31.12+19. 36 2

5.5 1.25 1.5 1.5 0.45 0.45 6 3 2.5 2


6.08+1.8 2

12 12 12 19.36 5.88 19.36 0.75 0.75 1.85 1.5 2

m3 m3 3 m m3 m3 m3 3 m m3 m3 m3 3 m Total=

15 31.12 31.12 31.12 31.12 4 8.31

12.8 PCC M-15 = 12 c/wall


Apron Base

18.86 1 19.36 0.15

0.15 15.7 0.15 5.88 Total=

m3 m3 m3 m3 m
3

15 2
31.12+19. 36 2

12.8 RCC M35(open


foundation)

m3 19.36 0.25 0.25 1.2 1.5 1.5 1.5 4.5 12 12 12 3 Total= m3 m3 m3 m3

0.00 348.48 9.00 9.00 32.40 398.88 13117.28 8600.00 573.51 764.44 3240.00 26295.24 26.30 4.92 3.78 118.747 2.700 53.976 11.98 196.10

m/wall 4 12.40 Reinforcement in foundation = 25 mm dia 20 mm dia 12 mm dia 12 m/wall mm dia

2 2 2

2 2

17.00 13.5 10 2 100

100 kg 129 kg 64.52 kg 430 32.4 Total = Total =


kg kg kg

Tonne

13.5 Substructure (M35) RCC Dirt wall = Abutment cap = Abutment = Pier Cap Pier M/wall

2 2 2 1 2

0.82 0.7
0.7+1.5 2 0.225 1 0.2+0.45 2

12 12 12 12 12 6.143

0.25 m3 0.225 m3 4.498 m3 1 m3 4.498 m3 3 m3 Total=

Sl. Item No. no. 6 13.5 Substructure (M20) PCC Wing wall-201.51

Unit

Qty for 2Lane

m3

201.51

13.6 Reinforcement in substuctureDirt wall = 12 mm dia 12 mm dia Abutment cap = 12 12 12 12 25 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia

2 2 2 2

0.95 10 1.85

6 2 13.5 86 10 1.85

26.55 kg 86 kg kg kg 13.5 86 kg kg

283.20 290.49 240.00 282.84 120.00 141.42 6215.51 728.00 2933.33 12431.02 1456.00 5866.67 1197.00 32185.48 32.19 174.28

Pier cap

Pier

2 30 2 2 2 2 27.3 30 m/wall

110 27.3 110 110 30 110 11.97

7.323 kg 30 kg 1 kg 7.323 kg kg 1 kg 100 kg Total = kg Total = Tonne 87.14 m3

Abutment

14.1 Furnished and placing


reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing

14.2

6.076

MT

12.152

10

14.2

12

Nos.

36.00

11

8.22

27.36 m

54.72

12

14.7

27.36 m

27.36

13

14.2

27.36 m2

82.08

Sl. Item No. no. 14 14.4 Providing and laying Cement concrete
Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material . Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

Unit 8.50 27.36 m3

Qty for 2Lane 232.56

15 16

14.9 13.9

2 2 12

2 4.00

Nos.

8 488.928

5.093 m3

17

14.1

0.3

12.00

m3

28.80

18 14.10

0.15

12.00

m3 Nos.

14.40

19

13.8

20

40

20

8.51

30

Nos.

60

21

8.4

17.28

17.28

22

8.47

Nos.

23

15.1

210.1 m3

210.06

24

15.9

153.4 m3

153.396

25 15.10 26 Analy
sis rate

1 2

92.36 m3 27.36 m

92.36 54.72

Executive Engineer, PWD Nagaon NH Division, Nagaon

380.1336 490.875

20.86 7929.587 17.00 8344.875

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.237/1,Ch-236259
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

103.00 84.81

356.00 573.00

36,668.00 48,595.00

3/12.8

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

145.22

54.00

7,842.00

Cum Cum

1.19 27.79

6514.00 9030.00

7,759.00 250,944.00

4/12.40

Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

Item No. 1

Particulars/Descrption of items 2 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ steel/Shyam steel

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

tonne

2.78

73279.00

203,643.00

5/13.5

Cum

25.08

9169.00

229,936.00

6/13.6

Jindal Tonne 2.51 73343.00 183,871.00

(i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 7/14.1 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

Cum

16.84

10591.00

178,300.00

8/14.2

Item No. 1

Particulars/Descrption of items 2 (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2

Unit 3 tonne

Total Rate in Quantity Rs. 4 5 1.35 77554.00

Amount (Rs.) 6 104,450.00

9/14.18

10/8.22

11/14.7

Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

metre metre

31.88 15.94

4170.00 2044.00

132,940.00 32,582.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

2.00 24.00

10197.00 204.00

20,394.00 4,896.00

17/8.51

Each Each Each

4.00 12.00

3500.00 3400.00 298.00

13,600.00 3,576.00

Item No. 1 18/16.1

Particulars/Descrption of items 2 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

Unit 3 Sqm

Total Quantity 4 59.55

Rate in Rs. 5 78.00

Amount (Rs.) 6 4,645.00

19/16.17 Replacement of Expansion Joints complete


as per drawings.

metre Sqm

17.00 67.49

3628.00 59.00

61,676.00 3,982.00

Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface. 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 79 b)16 mm dia re-bar fastners 25% of 79 C)20 mm dia re-bar fastners 25% of 79 d)25 mm dia re-bar fastners 25% of 79

20/16.2

Sqm

15.13

614.00

9,288.00

Each Each Each Each

19.82 19.82 19.82 19.82

500.00 700.00 750.00 800.00

Total-

9,909.00 13,872.00 14,863.00 15,854.00 2,138,488.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br. No.237/1,Ch-236259


Sl.N Item o. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20.
Wing Wall(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab1 0.65 Dirt wall2 0.65 Abut/Pier2 0.7+1.0 2 Raft-

Unit Qty for 2Lane 2 51.50 Cm 9 13.5 15.9 3.95 3.95 4.02 Cm Cm Cm Cm Cm Cm 103.00 1.11 1.89 3.19 19.00 1.28 26.97 31.36 84.81 50.02 95.20 145.22 1.19 1.19 27.79 27.79 2779.00 2779.00 2.78 23.50 1.575 25.08 2507.00 2507.00 2.5 16.84 16.84 1346.80 1346.80 1.35 2.00 24.00 24.00 24.00 24.00

0.9 0.175 0.2 7.4 0.25 3.95 1

7.94

3.95 Cm Total= Cm 1.8 4.0 m 3 m


3

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

7.94 3.5

3.5 3.4

Total= m3 3 12.8 PCC M157.94 1 0.15 m3 Total= 3.5 Total= 100 kg Total= kg Total= Tonne
3 3.95 m

12.8 RCC M35 (open foundation)-

7.94

12.40 Reinforcement in foundation-

27.79

13.5 Substructure(M35)-

2 2

0.7+1.0 2 0.25

3.5 3.5

0.9 m3 Total= m3 100 Kg Total= Kg Total= Tonne 7.4 m3 Total= m3 80 Kg Total= Kg Total= Tonne 2 12 12 12 12 Nos. Nos. Nos. Nos. Nos.

13.6 Reinforcement in Substructure-

25.07

14.1 Superstructure RCC (M25)-

3.5

0.65

14.2 Reinforcement in Superstructure-

16.835

10 11

14.9 Drainage Spouts complete as per drawing and Technical joint Providing & specification. fixing 20 mm 14.18 Filler
thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

1 2 2 2 2

Sl.N Item o. No. 12 14.10 PCC M15 grade levelling course 13 14.11
below approach slab complete as per drawing and technical Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) Replacement of Expansion Joints complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

11.5

4 4

0.3 0.3

Unit Qty for 2Lane 3 27.60 m m3 27.60

11.5

14

14.7

15.9 m

15.94

15

8.22

15.9 m

31.88

16

16.1

7.5

7.94

59.55

17 18

16.17 16.2

2 8.5

8.5

metre

17.00 67.49

7.94 metre

19

13.8

12

Nos.

24.00

20

8.47

Nos.

4.00

21

8.51

12

Nos.

12.00

22

16.28

0.65
2

2
0.7+1.0 2

2.5 sqm 3.95 sqm 7.94 sqm


Total- sqm

3.25 6.72 5.16 15.13

0.65

Sl.N Item o. No. 23 16.53 Providing, placing and fixing in


position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in

Unit Qty for 2Lane 47.56 Each 79 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.237-1,Ch-236259
Item No. 1 Particulars/Descrption of items 2 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete Cum pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

1703.15

54.00

91,971.00

132.20 265.46

6514.00 9030.00

861,134.00 2,397,140.00

13.79

73279.00

1,010,744.00

99.80

8120.00

810,376.00

90.76

9169.00

832,152.00

5/13.6

Item No. 1

Total Rate in Quantity Rs. 2 3 4 5 (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne 18.77 73343.00 bar of Fe-500 N/mm2 Super Structure Particulars/Descrption of items Unit
and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Amount (Rs.) 6 1,376,947.00

6/14.1 Furnishing

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4 Retro reflectorised Traffic sign:
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular

Cum

53.51

10591.00

566,725.00

MT

3.66

77554.00

283,615.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

Each

10/14.4 Providing and laying Cement concrete wearing coat M30 grade including reinforcement complete as per drawing and Technical Specifications

m3

17.28 135.49

5200.00 12993.00

89,856.00 1,760,422.00

Item Particulars/Descrption of items No. 1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Anal HAND RAIL ysis Providing and fixing hand rail over the crash barrier Rate consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

31.88 31.88

4170.00 1475.00

132,940.00 47,023.00

metre

15.94

2044.00

32,582.00

Cum Cum, Each

28.80 14.40 2.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 20,394.00

RM

47.82

160.00

7,652.00

(A) Granular material Cum 19/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

448.03

1524.00 204.00

682,801.00 0.00

Item Particulars/Descrption of items No. 1 2 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Each Each Each

4.00 25.00

3500.00 3400.00 298.00

13,600.00 7,450.00

Cum Cum Cum

52.95 120.42

4333.00 7046.00 1485.00

0.00 373,086.00 178,824.00

Cum

111.01

1679.00

186,386.00

Total- 12,250,080.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

4,360,989.00

3,019,475.00

4,131,320.00

738,296.00

Quantity Calculation fo Br. No.237/1 Ch-236259 Sl. Item No. no. 1 12.1 Earth work or
foundation of structures as per drawings & technical specification including setting out

Unit m 2 2 2 2 1.55 0.3 0.3


17.84+7.94 2
3

12 1.5 1.5 0.45 0.45 6 3 2.5 2


6.08+1.8 2

6.6 12 7.94 4.95 7.94 0.75 0.75 1.85 1.5 2 Total =

Qty for 2Lane 0.00 245.52 10.80 7.146 57.425 53.595 80.28 40.14 82.51 53.52 220.64 851.58

15 17.84 17.84 17.84 17.84 7

12.8 PCC M-15 = 12 c/wall Apron 2 15


17.84+7.94 2

m3 7.44 1 7.94 0.15 0.15 15.7 0.15 4.95 Total= 13.39 15.70 17.865 19.142 66.10 0.00 85.752 9.00 5.58 32.40 132.732

12.8 RCC M35(open


foundation)

m3 7.94 0.25 0.25 1.2 12 1.5 1.5 3 0.9 12 7.44 4.5 m3 m3 m3 m3 Total=

m/wall

2 2 2

12.40 Reinforcement in foundation = 25 mm dia 20 mm dia m/wall

17.68 25.8 100

80 80 32.4

kg kg kg Total = Total =

5456.79 5096.30 3240.00 13793.09 13.79

13.5 Substructure (M35) Dirt wall


Abutment cap

Abutment M/wall

2 2 2 2

12 0.225
0.7+0.9 2 0.2+0.45 2

0.25 12 3.792 3

0.65 0.7 12 5.267

m 3 m m3

3.90 3.78 72.81 10.27

Total= 6 13.5 Substructure (M20) PCC Wing wall-

90.76

99.8 m3

99.80

13.6 Reinforcement in substucture-

Sl. Item 7 13.6 No. no. Dirt wall Abutment cap

Unit MT

Qty for 2Lane 0.574 0.523

Abutment

28 12 12

mm dia mm dia mm dia

4 2 30 m/wall

95 30 95 100

6.1 27.4 1 10.27 Total = Total =

kg kg kg kg kg Tonne

11217.98 1461.33 5066.67 1027.00 18774.07 18.77 53.51

14.1 Furnished and placing


reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing 2 wall and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular Reinforced cement concrete approach 2 slab including reinforcement and formwork complete as per drawing and Technical specification.

53.51 m3

14.2

3.657

MT

3.66

10

14.2

12

Nos.

24.00

12

8.22

15.94 m

31.88

13

14.7

15.94 m

15.94

14

14.2

15.94 m2

47.82

15

14.4

8.50

15.94 m3

135.49

16 17

14.9 13.9

2 12 4.00

Nos.

2.00 448.03

4.667 m3

18

14.1

0.3

12.00

28.80

Sl. Item No. no. 19 14.10 PCC M15 grade levelling course
below approach slab complete as per drawing and technical specification Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

Unit 2 0.15 12.00 4 m3 Nos.

Qty for 2Lane 14.40

20

8.51

25.00

21

8.4

17.28

17.28

22

8.47

Nos.

4.00

23

15.1

120.42 m3

120.42

24

15.9

111.01 m3

111.01

25 15.10 26 Analysi
s Rate

1 2

52.95 m3 15.94 m

52.95 31.88

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.240/1,Ch-239322
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

248.70 119.44

356.00 573.00

88,538.00 68,439.00

3/12.8

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

Cum

206.11

54.00

11,131.00

Cum Cum

5.22 34.79

6514.00 9030.00

33,994.00 314,154.00

4/12.40 Reinforcement in Foundation: Supplying, fitting and

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications tonne 3.5 73279.00 254,938.00

5/13.5

Item No. 1

Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cum

34.29

9169.00

314,386.00

6/13.6

Tonne

3.43

73343.00

251,494.00

7/14.1

Cum

26.98

10591.00

285,724.00

8/14.2

tonne

2.16

77554.00

167,381.00

9/14.18

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

Item No. 1

Particulars/Descrption of items 2 (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete Construction of RCC railing of M30 Grade insitu with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Drainage Spouts complete as per drawing and Technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

Unit 3 metre

Total Quantity 4 24.00

Rate in Rs. 5 17.00

Amount (Rs.) 6 408.00

10/8.22

11/14.7

metre metre

35.88 17.94

4170.00 2044.00

149,620.00 36,670.00

12/14.11

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

13/14.10

14/14.9 15/13.8

Each Each

2.00 24.00

10197.00 204.00

20,394.00 4,896.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per
drawings.

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Each Each Each

4.00 12.00

3500.00 3400.00 298.00

13,600.00 3,576.00

Sqm

74.55

78.00

5,815.00

metre Sqm

17.00 84.49

3628.00 59.00

61,676.00 4,985.00

20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 107 b)16 mm dia re-bar fastners 25% of 107 C)20 mm dia re-bar fastners 25% of 107 d)25 mm dia re-bar fastners 25% of 107

Sqm

20.78

614.00

12,759.00

Each Each Each Each

26.79 26.79 26.79 26.79

500.00 700.00 750.00 800.00

13,396.00 18,755.00 20,094.00 21,434.00 Total- 2,722,252.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br. No.240/1,Ch-239322


Sl. Item No. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20
Wing Wall(B) Prestressed/ Reinforced cement grade M-20 & above Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab0.82 1 Dirt wall2 0.82 Abut/Pier0.7+1.0 2 Raft-

Unit Qty for 2Lane 2 124.35 Cm 10 14.915 17.94 3.95 3.95 6.135
Cm Cm Cm Cm Cm Cm

248.70 1.24 2.09 3.59 30.45 1.62 41.20 39.26 119.44 77.31 128.80 206.11 5.22 5.22 34.79 34.79 3479.00 3479.00 3.5 32.85 1.435 34.29 3429.00 3429.00 3.4 26.98 26.978 2158.24 2158.24 2.16 2.00 24.00 24.00 24.00 24.00 27.60

0.9 0.175 0.2 9.4 0.25 3.95 3.95

2 9.94

Cm 1 Total= Cm

12.1 Earth work in or foundation of structures


as per drawings & technical specification including setting out.(Upto 3m)-

9.95 3.5

3.5 4.6

2.22 4.0

m3 m3

Total= m3 3 12.8 PCC M159.94 3.5 0.15 m3 Total= 1 Total= 100 kg Total= kg Total= Tonne 6.135 m3

12.8 RCC M35 (open foundation)-

9.94

3.5

12.40 Reinforcement in foundation-

34.79

13.5 Substructure(M35)-

2 2

0.7+1.0 2 0.25

3.15 3.5

0.82 m3 Total= m3 100 Kg Total= Kg Total= Tonne 0.82 m3 Total= m3 80 Kg Total= Kg Total= Tonne 2 12 12 12 12 0.3 Nos. Nos. Nos. Nos. Nos. m3

13.6 Reinforcement in Substructure-

34.29

14.1 Superstructure RCC (M25)-

3.5

9.4

14.2 Reinforcement in Superstructure-

26.98

10 11

14.9 Drainage Spouts complete as per


drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 2 11.5
approach slab complete as per drawing and technical specification

1 2 2 2 2 4

12 14.10 PCC M15 grade levelling course below

Sl. Item No. No. 13 14.11 Reinforced cement concrete approach slab
including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm.

11.5

0.3

Unit Qty for 2Lane 3 27.60 m

14

14.7

17.94

17.94

15

8.22 Reinforced Cement Concrete Crash


Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness Replacement of Expansion Joints complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud)with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

17.94

35.88

16

16.1

7.5

9.94

74.55

17 16.17 18 16.2

2 8.5

8.5 9.94 metre

17.00 84.49

19

13.8

12

Nos.

24.00

20

8.47

Nos.

4.00

21

8.51

12

Nos.

12.00

22 16.28

0.82
2

2
0.7+1.0 2

0.25 6.135 1

sqm sqm sqm

0.41 10.43 9.94 20.78 107

9.94

Total- sqm

23

16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

64.3 0.6

Each

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.240-1,Ch-239322
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35

Cum

2365.72

54.00

127,750.00

Cum Cum

92.05 172.86

6514.00 9030.00

599,610.00 1,560,926.00

(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump

tonne

24.13

73279.00

1,768,101.00

Cum

434.89

8120.00

3,531,307.00

Cum

142.40

9169.00

1,305,641.00

Item No. 1 5/13.6

Particulars/Descrption of items 2 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

Unit 3 MT

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure 6/14.1 Furnishing and Placing Reinforced/Prestressed cement
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

17.04

73343.00

1,249,623.00

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

Cum

87.14

10591.00

922,900.00

MT

6.08

77554.00

471,219.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

Item No. 1 9/8.4

Particulars/Descrption of items 2
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

(V) 80cmm x 45 cm rectangular Each 10/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

17.28 152.49

5200.00 12993.00

89,856.00 1,981,303.00

B. M 40 grade concrete 12/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the in-charge. Management shall be made for 13/14.7 EngineerConstruction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification

metre metre

35.88 35.88

4170.00 1475.00

149,620.00 52,923.00

metre

17.94

2044.00

36,670.00

Cum Cum,

28.80 14.40

12025.00 5498.00

346,320.00 79,172.00

Item No.

Particulars/Descrption of items

Unit 3 Each

1 2 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 19/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Total Rate in Quantity Rs. 4 5 2.00 10197.00

Amount (Rs.) 6 20,394.00

RM

53.82

160.00

8,612.00

Cum Each

667.68 40.00

1524.00 204.00

1,017,545.00 8,160.00

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

Cum Cum Cum

73.25 166.59

4333.00 7046.00 1485.00

0.00 516,120.00 247,387.00

Cum

181.91

1679.00

305,427.00

Total-

16,470,954.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br. No.240/1, Ch-239322


Sl. No. 1 Item no. 12.1 Earth work or
foundation of structures as per drawings & technical specification including setting out

Unit

Qty for 2Lane 400.68 1079.50 10.80 9.31 114.817 67.095 111.06 55.53 114.145 74.04 328.754 2365.72 0.00 17.712 13.70 22.365 38.272 92.05

2 2 2 2 2

2.65 4.35 0.3 0.3


24.68+9.94 2

12 10.34 1.5 1.5 0.45 0.45 6 3 2.5 2


6.08+1.8 2

6.3 12 12 10.34 7.37 9.94 0.75 0.75 1.85 1.5 2

m m3 m3 3 m m3 m m3 3 m m3 m3 3 m Total =
3

15 24.68 24.68 24.68 24.68 10.43

12.8

PCC M-15 = 12 c/wall Apron 2 15


24.68+9.94 2

9.84 9.94 0.15

0.15 0.15 7.37

m3 m3 m3 m3 m
3

Total= 3 12.8 RCC M35(open


foundation)

m/wall

2 2 2

10.34 0.25 0.25 1.2

12 1.5 1.5 3

1 12 9.84 4.5

m3 m3 m3 Total=

124.08 9.00 7.38 32.40 172.86

12.40 Reinforcement in foundation = 32 mm dia 20 mm dia 12 mm dia 12 mm dia m/wall

2 2

11.14 13.2

110 68 10 310 100

46.48 2 32.4

kg kg kg kg kg

15491.48 4432.59 413.16 551.11 3240.00 24128.34 24.13

Total = kg Total = Tonne 5 13.5 Substructure (M35) Dirt wall =


Abutment cap =

Abutment = M/wall 6 13.5 Substructure PCC M20

2 2 2 2

0.82 0.7
0.7+1.0 2 0.2+0.45 2

12 12 5.91 6.735

0.25 0.225 12 3

m3 m3 m3

4.92 3.78 120.56 13.13

Total=

142.40

Sl. No. 6

Item no. 13.5 Wing wall1

Unit

Qty for 2Lane 434.89

434.89 m3

13.6

Reinforcement in substuctureDirt wall = 12 mm dia 12 mm dia Abutment cap = 12 mm dia 12 mm dia Abutment = 32 12 12 mm dia mm dia mm dia m/wall

2 2

0.95 2 2 2 2 33 100

6 2 10 1.85 80 33 80 13.13

26.55 86 13.5 86 8.24 27.3 1

kg kg kg kg

283.20 290.49 240.00 282.84 8333.59 1601.60 4693.33 1313.00 17038.06 17.04 87.14

kg kg kg kg Total = kg Total = Tonne 87.14 m3

14.1 Furnished and placing


reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. 14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing 14.4 Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical 14.9 Drainage Spouts complete as per drawing and Technical specification.

6.076

MT

6.076

10

12

Nos.

24.00

12

17.94

35.88

13

17.94

17.94

14

17.94

53.82

15

8.50

17.94

152.49

16

Nos.

Sl. No. 17

Item no. 13.9 Back filling behind Abutment ,Wing


wall and Return Wall complete as per drawing and technical specification with Granular Material. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and PCC M15 grade levelling course below approach slab complete as per drawing and technical Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

Unit

Qty for 2Lane 667.68

12

4.00

6.955

18

14.11

0.3

4.00

12

28.80

19

14.10

0.15

4.00

12

m3 Nos.

14.40

20

13.8

40

40

21

8.47

Nos.

22

8.4

17.28

17.28

23

15.11

166.59 m3

166.59

24

15.9

181.91 m3

181.91

25

15.10

1 2

73.25 17.94

m3 m

73.25 35.88

26 Analysis HAND RAIL


rate

Executive Engineer, PWD Nagaon NH Division, Nagaon

RPM

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.245/3,Ch-244803 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per specification, including setting shoring and bracing, removal deleterious matter, dressing of backfilling with approved material. drawing and technical out, construction of of stumps and other sides and bottom and

Unit 3

Total Quantit 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

100.74 112.53

356.00 573.00

35,864.00 64,478.00

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 4/12.40 Reinforcement in Foundation: Supplying,
fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

Cum

197.22

54.00

10,650.00

Cum Cum

1.64 38.29

6514.00 9030.00

10,690.00 345,759.00

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure 5/13.5 Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications

3.83

73279.00

280,586.00

Item No. 1

Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35

Unit 3

Total Quantit 4

Rate in Rs. 5

Amount (Rs.) 6

a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. tonne

22.12

9169.00

202,822.00

2.21

73343.00

162,235.00

32.76

10591.00

346,962.00

2.62

77554.00

203,254.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

Total Quantit 4

Rate in Rs. 5

Amount (Rs.) 6

B. M 40 grade concrete metre 11/14.7 Construction of RCC railing of M30 Grade in-situ metre with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade Cum rebar 13/14.10 PCC M15 grade levelling course below approach Cum slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Each Technical specification 15/13.8 Providing weep holes in brick Each mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud

37.88 18.94

4170.00 2044.00

157,960.00 38,714.00

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

2.00 20.00

10197.00 204.00

20,394.00 4,080.00

Each Each

4.00

3500.00 3400.00

13,600.00

Item No.

Particulars/Descrption of items

Unit 3 Each

1 2 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.

Total Quantit 4 12.00

Rate in Rs. 5 298.00

Amount (Rs.) 6 3,576.00

Sqm

82.05

78.00

6,400.00

19/16.17 Replacement of Expansion Joints complete as per metre 20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 97 b)16 mm dia re-bar fastners 25% of 97 C)20 mm dia re-bar fastners 25% of 97 d)25 mm dia re-bar fastners 25% of 97 Sqm

17.00 92.99

3628.00 59.00

61,676.00 5,487.00

Sqm

16.17

614.00

9,926.00

Each Each Each Each

24.14 24.14 24.14 24.14

500.00 700.00 750.00 800.00

Total-

12,070.00 16,897.00 18,104.00 19,311.00 2,595,898.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br. No.245/1,Ch-244803 m


Sl. Item No. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20
Wing Wall(B) Prestressed/ Reinforced cement grade M-20 & above Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab1 0.9 Dirt wall2 0.9 Abut/Pier2 0.7+1.0 2 Raft-

Unit

Qty for 2-Lane 100.74 1.36 2.23 3.79 36.97 1.78 23.19 43.21 112.53 71.22 126.00 197.22 1.64 1.64 38.29 38.29

2 0.9 0.175 0.2 10.4 0.25 3.95 1

50.37 11 15.915 18.94 3.95 3.95 3.453

Cm Cm Cm Cm Cm Cm Cm

10.94

3.95 Cm Total= Cm 1.86 4.0 m3 3 m

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

10.94 3.5

3.5 4.5

12.8

PCC M15-

10.94

Total= m3 0.15 m3 Total= 3.5 Total=

12.8 RCC M35 (open foundation)-

10.94

12.40 Reinforcement in foundation-

38.29

100 kg 3829.00 Total= kg 3829.00 Total= Tonne 3.83 3.453 m3 20.55 1.575 22.12

13.5 Substructure(M35)-

2 2

0.7+1.0 2 0.25

3.5 3.5

0.9 m3 Total= m3

13.6 Reinforcement in Substructure-

22.12

100 Kg 2212.00 Total= Kg 2212.00 Total= Tonne 2.21 0.9 m3 Total= m3 32.76 32.76

14.1 Superstructure RCC (M25)-

3.5

10.4

14.2 Reinforcement in Superstructure-

32.76

80 Kg 2620.80 Total= Kg 2620.80 Tonne Total= 2.62 2 12 12 12 12 0.3 Nos. Nos. Nos. Nos. Nos. 3 m 2.00 24.00 24.00 24.00 24.00 27.60

10 11

14.9 Drainage Spouts complete as per


drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 2 11.5 below approach slab complete as per drawing and technical

1 2 2 2 2 4

12 14.10 PCC M15 grade levelling course

Sl. Item No. No. 13 14.11 Reinforced cement concrete


approach slab including reinforcement and formwork complete as per drawing and Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

Unit
2 11.5

0.3

m3

Qty for 2-Lane 27.60

14

14.7

18.94

18.94

15

8.22

18.94

37.88

16

16.1

7.5

10.94

82.05

17 16.17 Replacement of Expansion Joints 18 16.2


complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud)with detachable battery.

2 8.5

8.5 10.94 metre

17.00 92.99

19

13.8

10

Nos.

20.00

20

8.47

Nos.

4.00

21

8.51 RPM: Providing relfective


pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 16.28 Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

12

Nos.

12.00

22

0.9
2

2
0.7+1.0 2

0.25 3.453 10.94

sqm sqm sqm

0.45 5.87 9.85 16.17

0.9

Total- sqm

Sl. Item No. No. 23 16.53 Providing, placing and fixing in


position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

Unit 57.932 Each 0.6

Qty for 2-Lane 97

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.245/3,Ch-244803
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of foundation
of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Rate in Quantity Rs. 4 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

1772.80

54.00

95,732.00

Cum Cum

94.95 173.95

6514.00 9030.00

618,487.00 1,570,733.00

3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

17.51

73279.00

1,283,456.00

121.04

8120.00

982,845.00

96.28

9169.00

882,803.00

Item No. 1

Particulars/Descrption of items

Unit

Total Rate in Quantity Rs. 4 19.10 5 73343.00

Amount (Rs.) 6 1,400,960.00

2 3 (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure
in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

6/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement MT bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate metre in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular

106.40 10591.00

1,126,883.00

7.05

77554.00

546,524.00

24.00

1640.00

39,360.00

24.00

558.00

13,392.00

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

9/14.4

Providing and laying Cement concrete wearing coat M- m3 30 grade including reinforcement complete as per drawing and Technical Specifications

17.28 5200.00 160.99 12993.00

89,856.00 2,091,744.00

Item No.

Particulars/Descrption of items

Unit 3

Total Rate in Quantity Rs. 4 5

Amount (Rs.) 6

1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification.

metre metre

37.88 37.88

4170.00 1475.00

157,960.00 55,873.00

metre

18.94

2044.00

38,714.00

Cum Cum, Each

28.80 14.40 2.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 20,394.00

RM

56.82

160.00

9,092.00

(A) Granular material Cum 18/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

477.60 40.00

1524.00 204.00

727,863.00 8,160.00

Item No.

Particulars/Descrption of items

Unit

Total Rate in Quantity Rs. 4 5

Amount (Rs.) 6

1 2 3 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 20/8.51 Providing relfective pavement marker with Micro prismatic Each lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
21/15.10 Curtain wall complete as per drawing and Technical

4.00 30.00

3500.00 3400.00 298.00

13,600.00 8,940.00

specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Cum Cum Cum

63.75 144.99

4333.00 7046.00 1485.00

0.00 449,183.00 215,311.00

Cum

112.28

1679.00 Total-

188,519.00 13,069,892.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br. No.245/3 , Ch- 244803


Sl. No. 1 Item no. 12.1
Earth work or foundation of structures as per drawings & technical specification including setting out.

Unit Qty for 2Lane 2 2 2 2 2 2.15 2.89 0.3 0.3


21.48+10.94 2

12 11.65 1.5 1.5 0.45 0.45 6 3 2.5 2 6.08+1.8 2

4.88 12 12 8.34 5.27 10.94 0.75 0.75 1.85 1.5 2

m 3 m 3 m 3 m m3 m3 m3 m3 3 m 3 m 3 m Total =

0.00 251.81 808.044 10.80 7.51 76.88 73.85 96.66 48.33 99.35 64.44 235.14 1772.80 0.00 18.79 15.70 35.84 24.62 94.95 0.00 124.72 9.00 7.83 32.40 173.946

15 21.48 21.48 21.48 21.48 4 7.46

12.8

PCC M-15 = 12 c/wall Apron 2


21.48+10.94 2 15

10.44 1 0.15 10.94

0.15 15.7 7.37 0.15

m m3 m3 m3 Total= m3

12.8

RCC M35(open foundation)

m/wall

2 2 2

12 0.25 0.25 3

0.95 1.5 1.5 1.2

10.94 12 10.44 4.5 Total=

m3 m3 m3

12.40 Reinforcement in foundation = 25 mm dia 20 mm dia 12 mm dia 12 mm dia m/wall

2 2

10 12.95 10 310 100

112 kg 73 kg 46.48 kg 2 kg 32.4 kg Total = kg Total = Tonne

8641.98 4668.40 413.16 551.11 3240.00 17514.64 17.51

13.5

Substructure (M35) Dirt wall =


Abutment cap =

Abutment = M/wall 6 7 13.5 13.6 Substructure (M20) PCC Wing wallReinforcement in substucture-

2 2 2 2

0.9 0.7
0.7+0.95 2 0.2+0.45 2

12 12 3.85 3

0.25 0.225 12 5.575 Total= 1 121.04

m3 3 m m3 m3

5.40 3.78 76.23 10.87 96.28

m3

121.04

Sl. No. 7

Item no. Dirt wall = 12 12 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 2 6 0.78 10 1.85 2 2 27 m/wall 26.12 2 13.5 86 93 26.5 120 100 86

Unit Qty for 2Lane Kg Kg Kg Kg 6.125 Kg 27 Kg 1.2 Kg 10.87 Kg Total = Kg Total = Tonne 106.40 m3 278.61 238.51 240.00 282.84 8790.51 1272.00 6912.00 1087.00 19101.47 19.10 106.40

Abutment cap =

Abutment =

14.1

14.2

10

14.18

11

8.22

12

14.7

13

14.16

14

14.4

15 16

14.9 13.9

17

14.11

18

14.10

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material . Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification

7.047

MT

7.05

12

Nos.

24.00

18.94

37.88

18.94

18.94

18.94

m2

56.82

8.50

18.94

160.99

1 2 12 4.98

2 4

Nos. m3

2.00 477.60

0.3

12.00

m3

28.80

0.15

12.00

m3

14.40

Sl. No. 19

Item no.
Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. 8.4 Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 15.11 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond 15.9 Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. 15.10 Curtain wall complete as per drawing and Technical specification Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

Unit Qty for 2Lane 8 5 Nos. 40.00

13.8

20

Nos.

30.00

21

Nos.

4.00

22

17.28

17.28

23

144.99

m3

144.99

24

112.28

m3

112.28

25 26

1 2

63.75 18.94

m3 m

63.75 37.88

Executive Engineer, PWD Nagaon NH Division, Nagaon

380.1336 490.875

11.89 10.00

4519.789 4908.75

380.1336 490.875

120.00 45616.03 93.00 45651.38

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali bypass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no - 250/4, Ch-249990
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

98.16 136.11

356.00 573.00

34,945.00 77,993.00

3/12.8

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

291.42

54.00

15,737.00

Cum Cum

6.15 57.44

6514.00 9030.00

40,087.00 518,639.00

4/12.40 Reinforcement in Foundation: Supplying, fitting and


placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications tonne 5.74 73279.00 420,915.00

5/13.5

Item No. 1

Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cum

23.87

9169.00

218,903.00

6/13.6

7/14.1

8/14.2

(i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel tonne

2.4

73343.00

175,070.00

32.76

10591.00

346,962.00

(i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

2.62

77554.00

203,254.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

37.88 18.94

4170.00 2044.00

157,960.00 38,714.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

2.00 30.00

10197.00 204.00

20,394.00 6,120.00

Each Each

4.00

3500.00 3400.00

13,600.00

Item No.

Particulars/Descrption of items

Unit 3 Each

1 2 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per
drawings.

Total Quantity 4 10.00

Rate in Rs. 5 298.00

Amount (Rs.) 6 2,980.00

Sqm

82.05

78.00

6,400.00

metre Sqm

17.00 92.99

3628.00 59.00

61,676.00 5,487.00

20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 106 b)16 mm dia re-bar fastners 25% of 106 C)20 mm dia re-bar fastners 25% of 106 d)25 mm dia re-bar fastners 25% of 106

Sqm

32.60

614.00

20,017.00

Each Each Each Each

26.44 26.44 26.44 26.44

500.00 700.00 750.00 800.00

13,221.00 18,510.00 19,832.00 21,154.00 Total- 3,002,973.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br.No-250/4 ,Ch-249990


Sl. Item Unit Qty for No. No. 2-Lane 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20. Wing Wall2 49.08 Cm 98.16
(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 0.9 Rail2 2 0.2 0.175 Kerb2 0.5 0.2 Slab1 10.4 0.9 Dirt wall2 0.25 0.9 0.7+1.5 2.896 Abut/Pier2 2 Raft10.94 3.95

11 15.92 18.94 3.95 3.95 3.95

Cm Cm Cm Cm Cm Cm

1.36 2.23 3.79 36.97 1.78 25.17 64.82 136.11 84.53 206.89 291.42 6.15 6.15 57.44 57.44

1.5 Cm Total= Cm 2.1 4.0 m3 m3

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

11.5 3.5

3.5 7.389

Total= m3 3 12.8 PCC M1511.24 3.65 0.15 m3 Total= 1.5 Total=

12.8 RCC M35 (open foundation)-

10.94

3.5

12.40 Reinforcement in foundation-

57.44

100 kg 5744.00 Total= kg 5744.00 Total= Tonne 5.74


3 2.896 m

13.5 Substructure(M35)-

2 2

0.7+1.5 2

3.5 0.25

22.30 1.575 23.87

0.90

3.5 m3 Total= m3

13.6 Reinforcement in Substructure-

23.87

100 Kg 2387.00 Total= Kg 2387.00 Total= Tonne 2.4 0.9 m3 Total= m3 32.76 32.76

14.1 Superstructure RCC (M25)-

3.5

10.4

14.2 Reinforcement in Superstructure-

32.76

80 Kg 2620.80 Total= Kg 2620.80 Total= Tonne 2.62 2 12 12 12 12 0.3 Nos. Nos. Nos. Nos. Nos. m3 2.00 24.00 24.00 24.00 24.00 27.60

10 14.9 Drainage Spouts complete as per drawing and Technical joint Providing & fixing 20 11 14.18 Filler
mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to

1 2 2 2 2
2 11.5

12

13

11.5

0.3

m3

27.60

14

18.94 m

18.94

15

8.22 Reinforced Cement Concrete


Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) Replacement of Expansion Joints complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud)with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

18.94 m

37.88

16

16.1

7.5

10.94

82.05

17 16.17 18 16.2

2 8.5

8.5 10.94 metre

17.00 92.99

19

13.8

15

Nos.

30.00

20

8.47

Nos.

4.00

21

8.51

10

Nos.

10.00

22 16.28

2
2

0.9
0.7+1.5 2

0.25 2.9

sqm sqm

0.45 6.38 16.41 9.36 32.60 106

1.5 0.9

10.94 sqm 10.4 sqm


Total- sqm 63.46 Each 0.6

23

16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No-250/4, Ch-249990
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35

Cum

859.13

54.00

46,394.00

Cum Cum

86.19 245.78

6514.00 9030.00

561,467.00 2,219,349.00

(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

tonne

25.21

73279.00 1,847,449.00

Cum

195.77

8120.00

1,589,653.00

Cum MT

91.37

9169.00

837,728.00

5/13.6

Item No. 1

Particulars/Descrption of items 2 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Tonne

20.99

73343.00 1,539,567.00

6/14.1 Furnishing and Placing Reinforced/Prestressed cement

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular

Cum

106.40

10591.00 1,126,883.00

MT

7.05

77554.00

546,524.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

17.28

5200.00

89,856.00

Item No.

Particulars/Descrption of items

Unit

Total Quantity 4 160.99

Rate in Rs.

Amount (Rs.)

1 2 3 10/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications. 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. metre metre

5 6 12993.00 2,091,744.00

37.88 37.88

4170.00 1475.00

157,960.00 55,873.00

metre

18.94

2044.00

38,714.00

Cum Cum,

28.80 14.40

12025.00 5498.00

346,320.00 79,172.00

Each

4.00

10197.00

40,788.00

RM

56.82

160.00

9,092.00

Item No. 1

Particulars/Descrption of items

Unit 3 Cum Each

Total Quantity 4 516.96 30.00

Rate in Rs. 5 1524.00 204.00

Amount (Rs.) 6 787,848.00 6,120.00

2 (A) Granular material 19/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

21/8.51

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

22/15.10

23/15.11

Cum Cum Cum

66.07 150.26

4333.00 7046.00 1485.00

0.00 465,530.00 223,137.00

24/15.9

Cum

158.41

1679.00

265,971.00

Total- 15,047,507.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br. No.250/4, Ch-249990 Sl. Item no. No. 1 12.1
Earth work or foundation of structures as per drawings & technical specification including setting out.

Unit

Qty for 2Lane

2 2 2

10.94 10.94 11.5 22.26


22.26+10.94 2

12 0.25 0.25 9 2.8 10.94 1.85 1.5

3.16 1.5 1.5 0.75 0.45 0.4 2.5 2

m3 3 m m3 m3 m3 m3 m3 3 m Total =

414.84 8.21 8.63 150.26 41.83 65.64 102.95 66.78 859.13 0.00 19.69 24.62 28.19 13.70 86.19 0.00 196.92 9.00 7.46 32.40 245.78

15 22.26 22.26

12.8

PCC M-15 = 12 10.94 2 c/wall


22.26+10.94 2

10.94 15 5.66 1

0.15 0.15 0.15 13.7

m3 m3 m3 m3 Total= m3

12.8

RCC M35(open foundation)

m/wall

2 2 2

12 0.25 0.25 1.2

1.5 1.5 1.5 3

10.94 12 9.94 4.5 Total=

m3 m3 m3 m3

12.40

Reinforcement in foundation = 25 mm dia 16 mm dia 12 mm dia 12 mm dia m/wall

2 2

120 104

12.94 27.5 10 305 100

kg kg 45.95 kg 2 kg 32.4 kg Total = kg Total = Tonne

11981.48 9039.01 408.44 542.22 3240.00 25211.16 25.21

13.5

Substructure (M35) Dirt wall


Abutment cap

Abutment M/wall

2 2 2 2

0.9 0.7
0.7+1.5 2 0.2+0.45 2

12 12 12 5.985

0.25 m3 0.225 m3 2.671 m3 3 Total= m


3

5.40 3.78 70.51 11.67 91.37

13.5

Substructure (M20) PCC Wing wall-

195.77 m3

195.77

Sl. Item no. No.

Unit

Qty for 2Lane

13.6

Reinforcement in substuctureDirt wall 12 mm dia 12 mm dia Abutment cap 12 12 32 12 12 mm dia mm dia mm dia mm dia mm dia

2 2 2 2 2 2 2

6 0.78 10 1.85 2 18 18 m/wall

26.55 2 13.5 86 100 27.3 100 100

86

kg kg kg kg

283.20 238.51 240.00 282.84 13906.17 873.60 4000.00 1167.00 20991.32 20.99 106.40

Abutment

14.1

14.2

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification.

kg kg 1.25 kg 11.67 kg Total = kg Total = Tonne 106.40 m3

5.5

7.047 MT

7.047

10

14.18

12

Nos.

24.00

12

8.22

18.94 m

37.88

13

14.7

18.94 m

18.94

14

14.16

18.94 m2

56.82

15

14.4

8.5

18.94 m3

160.99

16

14.9

Nos.

Sl. Item no. No. 17


Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised 8.4 Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 15.11 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 15.9 Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. 15.10 Curtain wall complete as per drawing and Technical specification. Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

Unit

Qty for 2Lane 516.96

13.9

12

4.00

5.385 m3

18

0.3

4.00

12

28.80

19

0.15

4.00

12

14.40

20

Nos.

30

21

Nos.

4.00

22

17.28

17.28

23

150.26 m3

150.26

24

158.41 m3

158.41

25 26

1 2

66.07 m3 18.94 m

66.07 37.88

Executive Engineer, PWD Nagaon NH Division, Nagaon

Executive Engineer, PWD

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no 251/1 , Ch-250350
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

60.12 126.12

356.00 573.00

21,403.00 72,265.00

2/12.1 Excavation for Structures (Earth work in excavation of

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 4/12.40 Reinforcement in Foundation: Supplying, fitting and
placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

Cum

316.51

54.00

17,092.00

Cum Cum

8.57 80.64

6514.00 9030.00

55,851.00 728,180.00

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications

tonne

8.06

73279.00

590,922.00

2 3 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Cum

Item No. 1

Particulars/Descrption of items

Unit

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

25.22

9169.00

231,207.00

2.5

73343.00

184,898.00

33.67

10591.00

356,599.00

tonne

2.69

77554.00

208,900.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

Item Particulars/Descrption of items No. 1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.1 Reinforced cement concrete approach slab 1 including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.1 PCC M15 grade levelling course below approach 0 slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

46.72 23.36

4170.00 2044.00

194,823.00 47,748.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

4.00 30.00

10197.00 204.00

40,788.00 6,120.00

Each Each

4.00

3500.00 3400.00

13,600.00

Item Particulars/Descrption of items No. 1 2 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.1 Replacement of Expansion Joints complete as per drawings. 7 20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.2 (A)'Supplying and applying Epoxy based bonding 8 agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.5 Providing, placing and fixing in position Chemical 3 rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 139 b)16 mm dia re-bar fastners 25% of 139 C)20 mm dia re-bar fastners 25% of 139 d)25 mm dia re-bar fastners 25% of 139

Unit 3 Each

Total Quantity 4 15.00

Rate in Rs. 5 298.00

Amount (Rs.) 6 4,470.00

Sqm

115.20

78.00

8,986.00

metre Sqm

25.50 130.56

3628.00 59.00

92,514.00 7,704.00

Sqm

29.64

614.00

18,199.00

Each Each Each Each

34.82 34.82 34.82 34.82

500.00 700.00 750.00 800.00

Total-

17,408.00 24,372.00 26,112.00 27,853.00 3,572,801.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br.no-251/1 ,Ch-250350


Sl.N Item o. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20
Wing Wall(B) Prestressed/ Reinforced cement grade M-20 & above Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab2 0.65 Dirt wall2 0.25 Abut/Pier2 0.7+1.0 2

Unit Qty for 2Lane 2 30.06 13 19.785 23.36 3.95 3.95 3.95 3.95 1 Total= 2.66 4.0 Cm Cm Cm Cm Cm Cm Cm Cm Cm Cm 3 m 3 m 60.12 1.61 2.77 4.67 38.00 1.28 17.11

0.9 0.175 0.2 7.4 0.65 2.548 2.548 3.95 3.5 6.15

1
Raft-

1 15.36 15.5 3.5

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

60.67 126.12 144.31 172.20 316.51 8.57 8.57 80.64 80.64

12.8 PCC M15-

15.66

3.65

Total= m3 0.15 m3 Total= 1.5 Total=

12.8 RCC M35 (open foundation)-

15.36

3.5

12.40 Reinforcement in foundation-

80.64

13.5 Substructure(M35)2 0.7+1.0 2 1.00 0.65 3.5 3.5 3.5 25.21

100 kg 8064.00 Total= kg 8064.00 Total= Tonne 8.06 0.00 3 15.16 m 2.548 2.548 0.25 Total= 100 Total= Total= 0.65 Total= 80 Total= Total= 2 12 12 12 12 8.918 1.138 25.22 2521.00 2521.00 Tonne 2.5 33.67 m3 33.67 m3 Kg 2693.60 Kg 2693.60 Tonne 2.69 Nos. 4.00 Nos. Nos. Nos. Nos. 36.00 36.00 36.00 36.00 m3 m3 m3 Kg Kg

2 7 13.6 Reinforcement in Substructure-

8 9

14.1 Superstructure RCC (M25)14.2 Reinforcement in Superstructure-

3.5

7.4

2 33.67

10 11

14.9 Drainage Spouts complete as per


drawing and Technical specification.

2 3 3 3 3

14.18 Filler joint Providing & fixing 20 mm


thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

Sl.N Item o. No. 12 14.10 PCC M15 grade levelling course


below approach slab complete as per drawing and technical specification 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to spacing between vertical post Reinforced Cement Concrete Crash 8.22 centre Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed M-20cement grade of with existing 16.1 Removal concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

11.5

0.3

Unit Qty for 2Lane 3 27.60 m

13

11.5

0.3

27.60

14

23.36

23.36

15

23.36

46.72

16

7.5

15.36

115.20

17 18

16.17 Replacement of Expansion Joints


complete as per drawings.

3 8.5

8.5 15.36 metre

25.50 130.56

16.2 Removal of existing asphaltic


wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.

19

13.8 Providing weep holes in brick


mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe,

15

Nos.

30.00

20

8.47 Providing 'Sparkle Solar Road


Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud)with detachable battery. 8.51 RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 16.28 Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

Nos.

4.00

21

15

Nos.

15.00

22

2
2

0.65
0.7+1.0 2

0.25 2.55 15.36 7.4

sqm sqm sqm sqm

0.33 4.34 15.36 9.62

1 0.65

Sl.N Item o. No. 23


16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

Unit Qty for 2Lane Total- sqm 29.64 83.558 Each 139 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No : 251/1, Ch-250350
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35

Cum

1007.22

54.00

54,391.00

Cum

118.91 236.87

6514.00 9030.00

774,551.00 2,138,891.00

(II) Using Batching plant Transit mixer and concrete Cum pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications Cum MT

33.33

73279.00

2,442,574.00

74.80

8120.00

607,376.00

93.64

9169.00

858,552.00

Item No. 1

Particulars/Descrption of items

Unit

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure
and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

21.50

73343.00

1,577,210.00

6/14.1 Furnishing

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4 Retro reflectorised Traffic sign:
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular

Cum

107.02

10591.00

1,133,449.00

MT

7.31

77554.00

567,230.00

metre metre

36.00 36.00

1640.00 558.00

59,040.00 20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

10/14.4 Providing and laying Cement concrete wearing coat M30 grade including reinforcement complete as per drawing and Technical Specifications.

m3

17.28 198.56

5200.00 12993.00

89,856.00 2,579,891.00

Item No.

Particulars/Descrption of items

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analys HAND RAIL is Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
16/14.9 Drainage

metre metre

46.72 46.72

4170.00 1475.00

194,823.00 68,912.00

metre

23.36

2044.00

47,748.00

Cum Cum,

28.80 14.40 4.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 40,788.00

Spouts complete as per drawing and Each Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing
18/13.9 Back filling behind Abutment ,Wing wall and Return

RM per drawing and technical Cum

70.08

160.00

11,213.00

Wall complete as specification. (A) Granular material

393.41

1524.00

599,554.00

Item No. 1

Particulars/Descrption of items 2 concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

Unit 3 Each

Total Quantity 4 40.00

Rate in Rs. 5 204.00

Amount (Rs.) 6 8,160.00

19/13.8 Providing weep holes in brick mansonry/plain/reinforced

20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 21/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) Cum Cum B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick Cum comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring Cum at cross drainage works for relatively less important works 4.00

3500.00 3400.00 298.00 13,600.00 0.00

67.85 154.31

4333.00 7046.00 1485.00

0.00 478,072.00 229,151.00

168.17

1679.00

282,358.00

Total- 15,314,994.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.251/1 Ch-250350 m


Sl. No. 1 12.1 Earth work or
foundation of structures as per drawings & technical specification including setting out.

Unit

Qty for 2Lane 0.00 490.29 11.52 8.63 154.31 64.50 103.68 105.73 68.58 1007.22

2 2

15.36 15.36 11.5


22.86

2 22.86+15.362 15 22.86 22.86

12 0.25 0.25 9 3.75 15.36 1.85 1.5

2.66 1.5 1.5 0.75 0.45 0.45 2.5 2

m m3 m3 m3 m3 m3 3 m 3 m Total =

12.8 PCC M-15 = 12 15.36 2 22.86+15.362 c/wall 15.36 15 3.75 1 0.15 0.15 0.15 13.7 Total= m 3 m m3
3

27.65 34.56 43.00 13.70 118.91 0.00

12.8

RCC M35(open foundation)

m/wall

2 2 2

12 0.25 0.25 1.2

1 1.5 1.5 3

15.36 12 14.86 4.5 Total=

m3 m3 m3 m3

184.32 9.00 11.15 32.40 236.87

12.40 Reinforcement in foundation = 25 mm dia 16 mm dia 12 mm dia 12 m/wall mm dia

2 2

80 104

32.8 26.5 10 365 100

54.72 2

kg kg kg kg

20246.91 8710.32 486.40 648.89

32.4 kg 3240.00 Total = kg 33332.52 Total = Tonne 33.33

13.5 Substructure RCC-(M35) Dirt wall


Abutment cap

Abutment Pier Cap Pier M/wall

2 2 2 1 1 2

0.65 0.7
0.7+1.0 2 0.225 1 0.2+0.45 2

12 12 2.323 1 2.323 4.098

0.25 0.225 12 12 12 3 Total=

m 3 m m3 m3 3 m 3 m

3.90 3.78 47.39 2.70 27.88 7.99 93.64

13.5

Substructure (M20) PCC Wing wall-

74.8 m3

74.80

13.6 Reinforcement in substuctureDirt wall = 12 mm dia

26.55

kg

283.20

Sl. No. 12 Abutment cap = 12 12 Pier cap= 12 12 25 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 2 2 2 2 2 2 0.78 10 1.85 10 1.85 100 27.3 16 100 27.3 16 2 13.6 86.00 13.60 86.00 4.65 16 100 4.65 16 100 100 2 1.2 86.00

Unit kg kg kg kg kg kg kg kg

Qty for 2Lane 238.51 241.78 282.84 241.78 282.84 7175.93 776.53 3413.33

Abutment =

Pier=

m/wall

14.1 Furnished and placing


reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications.

kg 3587.96 kg 776.53 1.2 kg 3413.33 7.9 kg 790.00 Total = kg 21504.57 Total = Tonne 21.50 53.51 107.02 m3

14.2 Reinforcement in Super


Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

3.657

MT

7.31

10

12

Nos.

36.00

11

8.22 Reinforced Cement Concrete


Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing

23.36

46.72

12

23.36

23.36

13

23.36

70.08

14

14.4 Providing and laying Cement


concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.

8.50

23.36

m3

198.56

Sl. No. 15

Unit 14.9 Drainage Spouts complete as per


drawing and Technical specification. 13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. 8.4 Sign board : Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 15.11 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 15.9 Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works.

Qty for 2Lane 4.00

Nos.

16

12

4.00

4.098

m3

393.41

17

0.3

4.00

12

28.80

18

0.15

4.00

12

m3

14.40

19

40

Nos.

40.00

20

Nos.

4.00

21

17.28

17.28

22

154.31 m3

154.31

23

168.17 m3

168.17

24

15.10 Curtain wall complete as per

67.85

m m

67.85

drawing and Technical specification. 25 Analysi HAND RAIL s rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

23.36

46.72

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no- 252/1,Ch-251630
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

60.24 96.27

356.00 573.00

21,446.00 55,165.00

3/12.8

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and Cum concrete pump

172.60

54.00

9,321.00

5.61 52.19

6514.00 9030.00

36,521.00 471,231.00

4/12.40 Reinforcement in Foundation: Supplying, fitting and


placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications

5.22

73279.00

382,407.00

Item No. 1

Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

6/13.6

7/14.1

a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer Cum and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999.

17.41

9169.00

159,640.00

1.7

73343.00

126,591.00

B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

Cum

26.98

10591.00

285,724.00

tonne

2.16

77554.00

167,381.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

B. M 40 grade concrete metre 11/14.7 Construction of RCC railing of M30 Grade in- metre situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). Cum Cum

35.88 17.94

4170.00 2044.00

149,620.00 36,670.00

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

2.00 30.00

10197.00 204.00

20,394.00 6,120.00

Item No. 1

Particulars/Descrption of items

Unit 3 Each Each Each

2 a) Bi-directional Stud b) Uni-directional Stud 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per
drawings.

Total Quantity 4 4.00 10.00

Rate in Rs. 5 3500.00 3400.00 298.00

Amount (Rs.) 6 13,600.00 2,980.00

Sqm

74.55

78.00

5,815.00

metre Sqm

17.00 84.49

3628.00 59.00

61,676.00 4,985.00

20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface. 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 94 b)16 mm dia re-bar fastners 25% of 94 C)20 mm dia re-bar fastners 25% of 94 d)25 mm dia re-bar fastners 25% of 94

Sqm

22.62

614.00

13,891.00

Each Each Each Each

23.53 23.53 23.53 23.53

500.00 700.00 750.00 800.00

Total-

11,763.00 16,468.00 17,644.00 18,820.00 2,640,276.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br no.252/1,Ch-251630 m


Sl. Item No. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 . Wing Wall2
(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.3 0.25 Rail2 2 0.2 Kerb2 0.5 Slab1 0.82 Dirt wall2 0.25 Abut/Pier2 0.7+1.0 2 Raft-

Unit Qty for 2Lane 30.12 10 14.915 17.94 3.95 3.95 3.95 1 Total= 1.85 4.0 Total= Cm Cm Cm Cm Cm Cm Cm Cm Cm m m3 m3 m3
3

60.24 1.24 2.09 3.59 30.45 1.62 18.03 39.26 96.27 74.46 98.14 172.60 5.61 5.61 52.19 52.19

0.9 0.175 0.2 9.4 0.82 2.685 3.95

9.94

12.1 Earth work in or foundation of structures


as per drawings & technical specification including setting out.(Upto 3m)-

11.5 3.5

3.5 3.505

12.8 PCC M15-

10.24

3.65

0.15 Total= 1.5 Total=

12.8 RCC M35 (open foundation)-

9.94

3.5

12.40 Reinforcement in foundation-

52.185

100 kg 5218.50 Total= kg 5218.50 Total= Tonne 5.2 0.00 15.98 1.4 17.41

13.5 Substructure(M35)2 2 0.7+1.0 2 0.25 3.5 3.5 2.685 0.820 Total= m


3

m3 m3

13.6 Reinforcement in Substructure-

17.26

100 Kg 1726.00 Kg 1726.00 Total= Total= Tonne 1.7 0.82 Total= m 3 m


3

14.1 Superstructure RCC (M25)-

3.5

9.4

26.978 26.978

14.2 Reinforcement in Superstructure-

26.978

80 Kg 2158.24 Kg 2158.24 Total= Total= Tonne 2.16 2 Nos. 2.00

10

14.9 Drainage Spouts complete as per


drawing and Technical specification.

Sl. Item No. No. 11 14.18 Filler joint Providing & fixing 20 mm thick
compressible fibre board in expansion joint complete as per drawing & Technical Specification.

12 14.10 PCC M15 grade levelling course below


approach slab complete as per drawing and technical specification Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

11.5

2 2 2 2 4

12 12 12 12 0.3

Unit Qty for 2Lane Nos. 24.00 Nos. 24.00 Nos. 24.00 Nos. 24.00 27.60 m3 m3 27.60

13 14.11

11.5

0.3

14

14.7

17.94

17.94

15

8.22

17.94

35.88

16

16.1

7.5

9.94

74.55

17 16.17 Replacement of Expansion Joints


complete as per drawings.

2 8.5

8.5 9.94 metre

17.00 84.49

18

16.2 Removal of existing asphaltic wearing coat


comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.

19

13.8 Providing weep holes in brick


mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe.

15

Nos.

30.00

20

8.47 Providing 'Sparkle Solar Road


Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud)with detachable battery.

Nos.

4.00

21

8.51 RPM: Providing relfective pavement marker


with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

10

Nos.

10.00

22 16.28 Supplying and applying Epoxy based


bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

0.82
2

2
0.7+1.0 2

0.25 2.685 9.94 9.4


Total-

sqm sqm sqm sqm sqm

0.41 4.56 9.94 7.71 22.62

1 0.82

Sl. Item No. No. 23 16.53 Providing, placing and fixing in position
Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

56.46 0.6

Unit Qty for 2Lane Each 94

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br no : 252/1 ,Ch-251630
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35

Cum

627.34

54.00

33,877.00

Cum Cum

53.77 167.76

6514.00 9030.00

350,252.00 1,514,873.00

(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

tonne

17.02

73279.00

1,247,001.00

Cum

74.95

8120.00

608,594.00

Cum MT

66.89

9169.00

613,303.00

5/13.6

Item No. 1

Particulars/Descrption of items 2 (i) TMT Corrosion Resistant reinforcement bar of Fe-500 N/mm2 Super Structure Steel (CRS)

Unit 3 Tonne

Total Quantity 4 13.15

Rate in Rs. 5 73343.00

Amount (Rs.) 6 964,551.00

6/14.1

Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) MT reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper metre plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per metre drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications. 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

87.14

10591.00

922,900.00

6.08

77554.00

471,219.00

24.00

1640.00

39,360.00

24.00

558.00

13,392.00

24.00

317.00

7,608.00

24.00

17.00

408.00

152.49

12993.00

1,981,303.00

Item No. 1 11/Analy sis Rate

Particulars/Descrption of items 2 B. M 40 grade concrete HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Drainage Spouts complete as per drawing and Technical specification. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

Unit 3 metre metre

Total Quantity 4 35.88 35.88

Rate in Rs. 5 4170.00 1475.00

Amount (Rs.) 6 149,620.00 52,923.00

12/14.7

metre

17.94

2044.00

36,670.00

13/14.11

14/14.10 15/14.9 16/14.16

Cum Cum, Each

28.80 14.40 2.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 20,394.00

RM

53.82

160.00

8,612.00

17/13.9

18/13.8

Cum Each

336.48 20.00

1524.00 204.00

512,796.00 4,080.00

Item No.

Particulars/Descrption of items

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

1 2 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

20/8.51

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

21/15.10

22/15.11

Cum Cum Cum

51.76 117.72

4333.00 7046.00 1485.00

0.00 364,701.00 174,815.00

23/15.9

Cum

113.29

1679.00

190,214.00

Total- 10,722,558.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.252/1,Ch-251630


Sl. Item No. no. 1 12.1 Earth work or foundation of
structures as per drawings & technical specification including setting out.

Unit

Qty for 2Lane 0.00 172.96 7.46 9.00 117.72 67.10 120.13 80.66 52.32 627.34 0.00 16.28 15.12 22.37 0.00 53.77 0.00

2 2

9.94 0.25 0.25


17.44

15 2
17.44+9.94 2

12 9.94 12 9 0.45 9.75 1.85 1.5

1.45 1.5 1.5 0.75 9.94 0.45 2.5 2

m m3 3 m m3 m3 3 m m m3 Total = m3 m3 m3 m3
3

17.44 17.44

12.8 PCC M-15 = 11.5 2


17.44+9.44 2

9.44 3.75 0.15

0.15 0.15 9.94 Total=

15

12.8 RCC M35(open


foundation)

m/wall

2 2 2

12 0.25 0.25 3

1 1.5 1.5 1.2

9.94 12 9.44 4.5 Total=

m3 m3 3 m m3

119.28 9.00 7.08 32.40 167.76

12.40 Reinforcement in foundation = 25 mm dia 16 mm dia m/wall

2 2

100 80

12.94 15 100

kg kg 32.4 kg Total = Kg Total = Tonne 12 m3 0.225 m3 12 m3 4.105 m3 Total=

9984.57 3792.59 3240.00 17017.16 17.02 4.92 3.78 50.18 8.00 66.89

13.5 Substructure (M35) RCC Dirt wall =


Abutment cap =

Abutment = M/wall

2 2 2 2

0.82 0.7
0.7+1.0 2 0.2+0.45 2

0.25 12 2.46 3

13.5

Substructure (M20) PCC Wing wall-

74.95 m3

74.95

13.6 Reinforcement in substuctureDirt wall = 12 mm dia 12 mm dia

2 2

6 0.95

26.55 2

86

kg kg

283.20 290.49

Sl. Item No. no.

Unit

Qty for 2Lane

Abutment cap =

12 12 25 12 12

mm dia mm dia mm dia mm dia mm dia

2 2 2 2 2

10 1.85 2 17 17

13.5 86 100 27.3 100 100

Abutment =

m/wall

kg kg kg 4.8 kg kg 1 kg 8 kg Total = kg Total = Tonne 87.14 m3

240.00 282.84 7407.41 825.07 3022.22 800.00 13151.23 13.15 87.14

14.1 Furnished and placing


reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. 14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification.

6.076 MT

6.08

10 14.18 Filler joint Providing & fixing 20 mm

12

Nos.

24.00

12

8.22

17.94 m

35.88

13

14.7

17.94 m

17.94

14 14.16

17.94 m2

53.82

15

14.4

8.50

17.94 m3

152.49

16 17

14.9

1 2 12 4.00

Nos.

2.00 336.48

13.9 Back filling behind Abutment ,Wing wall


and Return Wall complete as per drawing and technical specification with Granular Material. 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification.

3.505 m3

18

0.3

4.00

12

28.80

Sl. Item No. no. 19 14.10 PCC M15 grade levelling course below
approach slab complete as per drawing and technical specification

Unit

Qty for 2Lane 14.40

0.15

4.00

12

20

13.8 Providing weep holes in brick


mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 dia AC pipe, Solar Road Providing 'Sparkle 8.47 mm Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery.

20

Nos.

20.00

22

Nos.

4.00

23 15.11 Stone apron Flexible Apron


:Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification. HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

117.72 m3

117.72

24

15.9

113.29 m3

113.29

25 15.10 26 Analys
is rate

1 2

51.76 m3 17.94 m

51.76 35.88

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no- 255/1,Ch-254000 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

68.22 99.39

356.00 573.00

24,287.00 56,954.00

2/12.1

3/12.8

I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

Cum

184.42

54.00

9,959.00

Cum Cum

5.61 52.185

6514.00 9030.00

36,521.00 471,231.00

4/12.40 Reinforcement in Foundation: Supplying, fitting and placing

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 5.22 73279.00 382,407.00

5/13.5

Item No. 1

Particulars/Descrption of items 2 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cum

20.18

9169.00

185,008.00

6/13.6

7/14.1

(i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump Cum

2.00

73343.00

146,907.00

ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

26.98

10591.00

285,724.00

tonne

2.16

77554.00

167,381.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

Item No.

Particulars/Descrption of items

Unit

1 2 3 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 11/14.7 Construction of RCC railing of M30 Grade in-situ metre with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Each Each

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

35.88 17.94

4170.00 2044.00

149,620.00 36,670.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

2.00 30.00

10197.00 204.00

20,394.00 6,120.00

4.00

3500.00 3400.00

13,600.00

Item No.

Particulars/Descrption of items

Unit

1 2 3 17/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing Sqm coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per metre
drawings.

Total Quantity 4 10.00

Rate in Rs. 5 298.00

Amount (Rs.) 6 2,980.00

74.55

78.00

5,815.00

17.00 84.49

3628.00 59.00

61,676.00 4,985.00

20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 99 b)16 mm dia re-bar fastners 25% of 99 C)20 mm dia re-bar fastners 25% of 99 d)25 mm dia re-bar fastners 25% of 99

Sqm

Sqm

23.41

614.00

14,376.00

Each Each Each Each

24.84 24.84 24.84 24.84

500.00 700.00 750.00 800.00

Total-

12,420.00 17,388.00 18,630.00 19,872.00 2,695,328.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br.no: 255/1,Ch-254000 m


Sl. No. 1 Item No. 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20
Wing Wall(B) Prestressed/ Reinforced cement grade M-20 & above Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab1 0.82 Dirt wall2 0.25 Abut/Pier2 0.7+1.0 2 Raft-

Unit Qty for 2Lane 2 34.11 10 14.915 17.94 3.95 3.95 3.95 1 Total= 2.16 4.0 Total= 0.15 Total= 1.5 Total= Cm Cm Cm Cm Cm Cm Cm Cm Cm 3 m m3 m3 m3 68.22 1.24 2.09 3.59 30.45 1.62 21.15 39.26 99.39 75.22 109.20 184.42 5.61 5.61 52.185 52.185 5218.50 5218.50 5.22 18.74 1.4 20.18 2003.00 2003.00 2.0 26.978 26.978 2158.24 2158.24 2.16 2.00 24.00 24.00 24.00 24.00 27.60

0.9 0.175 0.2 9.4 0.82 3.15 3.95 3.5 3.9

9.94 9.95 3.5

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

3 4

12.8 PCC M1512.8 RCC M35 (open foundation)-

10.24 9.94

3.65 3.5

12.40 Reinforcement in foundation-

52.185

100 kg Total= kg Total= Tonne 3.5 0.82 m3 Total= m3 100 Kg Kg Total= Total= Tonne 0.82 m3 Total= m3 80 Kg Kg Total= Total= Tonne 2 Nos. 12 12 12 12 0.3 Nos. Nos. Nos. Nos. m3

13.5 Substructure(M35)-

2 2

0.7+1.0 2 0.25

3.15 3.5 20.03

13.6 Reinforcement in Substructure-

8 9

14.1 Superstructure RCC (M25)14.2 Reinforcement in Superstructure-

3.5

9.4 26.978

10 11

14.9 Drainage Spouts complete as per


drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

1 2 2 2 2 4

12

14.10 PCC M15 grade levelling course


below approach slab complete as per drawing and technical specification

11.5

Sl. Item No. No. 13 14.11 Reinforced cement concrete


approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud)with detachable battery. 8.51 RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 16.28 Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

11.5

0.3

Unit Qty for 2Lane 3 27.60 m

14

17.94

17.94

15

17.94

35.88

16

7.5

9.94

74.55

17 18

2 8.5

8.5 9.94

metre metre

17.00 84.49

19

15

Nos.

30.00

20

Nos.

4.00

21

10

Nos.

10.00

22

0.82
2

2
0.7+1.0 2

0.25 3.15 9.94 9.4


Total-

sqm sqm sqm sqm sqm

0.41 5.36 9.94 7.71 23.41

1 0.82

Sl. Item No. No. 23 16.53 Providing, placing and fixing in


position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

59.616 0.6

Unit Qty for 2Lane Each 99

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No : 255/1, Ch-254000 m
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35

Cum

728.38

54.00

39,333.00

Cum

56.37 167.76

6514.00 9030.00

367,181.00 1,514,873.00

3/12.40

4/13.5

(II) Using Batching plant Transit mixer and concrete Cum pump Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications Cum

19.01

73279.00

1,393,333.00

412.69

8120.00

3,351,043.00

Cum MT

81.24

9169.00

744,890.00

5/13.6

Item No. 1

Particulars/Descrption of items

Unit

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

14.52

73343.00

1,065,279.00

6/14.1

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)

Cum

87.14

10591.00

922,900.00

7/14.2

MT

6.08

77554.00

471,219.00

8/14.18

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

9/8.4

(V) 80cmm x 45 cm rectangular

17.28

5200.00

89,856.00

Item No. 1 10/14.4

Particulars/Descrption of items

Unit

Total Quantity 4 152.49

Rate in Rs. 5 12993.00

Amount (Rs.) 6 1,981,303.00

11/8.22

2 3 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications. Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

B. M 40 grade concrete metre 12/Analysi HAND RAIL metre s Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- incharge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ metre with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.

35.88 35.88

4170.00 1475.00

149,620.00 52,923.00

17.94

2044.00

36,670.00

14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 15/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Each Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing RM 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum

28.80 14.40 2.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 20,394.00

53.82

160.00

8,612.00

381.12

1524.00

580,827.00

Item No. 1 19/13.8

Particulars/Descrption of items

Unit

Total Quantity 4 40.00

Rate in Rs. 5 204.00

Amount (Rs.) 6 8,160.00

20/8.47

2 3 Providing weep holes in brick Each mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). Each Each Each

a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

4.00

3500.00 3400.00 298.00

13,600.00 0.00

Cum Cum Cum

54.67 124.34

4333.00 7046.00 1485.00

0.00 385,205.00 184,638.00

Cum

121.20

1679.00

203,495.00

Total- 14,071,614.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.255/1 Ch-254000 m


Sl.No.

Item no.

Unit m 3 m m3 m3 m3 m3 3 m m m3 Total = m 11.5 2


18.42+9.44 2
15
3 3 3

12.1 Earth work or foundation of


structures as per drawings & technical specification including setting out.

2 2

9.94 0.25 0.25


18.42

18 2
18.42+9.94 2

12 9.94 12 9 0.45 4.24 1.85 1.5

2.62 1.5 1.5 0.75 9.94 0.45 2.5 2

Qty for 2Lane 0.00 312.51 7.46 9.00 124.34 80.51 54.11 85.19 55.26 728.381 0.00 16.28 17.72 22.365 56.37 0.00 119.28 9.00 7.08 32.40 167.76

18.42 18.42

12.8 PCC M-15 = 9.44 4.24 0.15 0.15 0.15 9.94

Total= 3 12.8
RCC M35(open foundation)

m3 2 2 2 12 0.25 0.25 3 1 1.5 1.5 1.2 9.94 12 9.44 4.5 Total= m3 m3 m3 m3

m/wall

12.40 Reinforcement in foundation = 25 mm dia 16 mm dia m/wall

2 2

120 80

12.94 15 100

kg kg 32.4 kg Total = kg Total = Tonne

11981.48 3792.59 3240.00 19014.07 19.01

13.5 Substructure (M35) RCC Dirt wall =


Abutment cap =

Abutment = M/wall

2 2 2 2

0.82 0.7
0.7+1.0 2
0.2+0.45 2

0.25 12 2.925 3

12 0.225 12 6.6 Total=

m3 m3 3 m

4.92 3.78 59.67 12.87 81.24

13.5

Substructure (M20) PCC Wing wall-

412.69 m3

412.69

13.6 Reinforcement in substuctureDirt wall = 12 mm dia 12 mm dia

2 2

6 0.95

26.55 2

86

kg kg

283.20 290.49

Sl.No.

Item no.

Unit Abutment cap = 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 10 1.85 2 20 100 m/wall 13.5 86 100 27.3 20 100 5.25 kg kg

Qty for 2Lane 240.00 282.84

Abutment =

kg 8101.85 kg 970.67 1 kg 3555.56 8 kg 800.00 Total = kg 14524.61 Total = Tonne 14.52 87.14 m
3

14.1 Furnished and placing


reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. 14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification.

87.14

6.076

MT

6.08

10

14.18 Filler joint Providing & fixing 20 mm


thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to 14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing

12

Nos.

24.00

11

17.94

35.88

12

17.94

17.94

13

17.94

m2

53.82

14

14.4 Providing and laying Cement concrete


Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. 14.9 Drainage Spouts complete as per drawing and Technical specification.

8.50

17.94

152.49

15 16

1 2 12 4.00

2 3.97

Nos. m
3

2 381.12

13.9 Back filling behind Abutment ,Wing


wall and Return Wall complete as per drawing and technical specification with Granular Material.

17

14.11 Reinforced cement concrete approach


slab including reinforcement and formwork complete as per drawing and Technical specification.

0.3

4.00

12

28.80

Sl.No.

Item no.

Unit 2 0.15 4.00 12 m3

18

14.10 PCC M15 grade levelling course


below approach slab complete as per drawing and technical specification 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe,

Qty for 2Lane 14.40

19

Nos.

40

20

8.47 Providing 'Sparkle Solar Road


Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery.

Nos.

21

8.4

Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3

17.28

17.28

22

15.11 Stone apron Flexible Apron


:Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall.

124.335 m3

124.34

23

15.9 Flore apron :Dry rubble Flooring,


Construcytion of dry rubbl flooring at cross drainage works for relatively less important works.

121.20 m3

121.20

24

15.10 Curtain wall complete as per drawing


and Technical specification.

1 2

54.67 17.94

m3 m

54.67 35.88

25 Analysi HAND RAIL


s rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-255/2, Ch-254750
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

52.66 134.75

356.00 573.00

18,747.00 77,213.00

2/12.1

I.Ordinary Soil B.Mechanical means


(II) With dewatering

3/12.8

(i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete Cum pump

324.10

54.00

17,502.00

8.57 53.76

6514.00 9030.00

55,851.00 485,453.00

4/12.40

Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications

5.38

73279.00

393,948.00

Item No. 1

Particulars/Descrption of items

Unit

6/13.6

2 3 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

23.95

9169.00

219,596.00

Tonne

2.40

73343.00

175,657.00

7/14.1

Cum

33.67

10591.00

356,599.00

8/14.2

tonne

2.69

77554.00

208,900.00

9/14.18

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

Item No. 1 10/8.22

Particulars/Descrption of items

Unit 3

2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

46.72 23.36

4170.00 2044.00

194,823.00 47,748.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

4.00 30.00

10197.00 204.00

40,788.00 6,120.00

Each Each

4.00

3500.00 3400.00

13,600.00

Item No. 1 17/8.51

Particulars/Descrption of items

Unit

2 3 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing Sqm coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per metre
drawings.

Total Quantity 4 15.00

Rate in Rs. 5 298.00

Amount (Rs.) 6 4,470.00

115.20

78.00

8,986.00

25.50 130.56

3628.00 59.00

92,514.00 7,704.00

20/16.2

Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.

Sqm

21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface. 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 139 b)16 mm dia re-bar fastners 25% of 139 C)20 mm dia re-bar fastners 25% of 139 d)25 mm dia re-bar fastners 25% of 139

Sqm

59.53

614.00

36,554.00

Each Each Each Each

34.82 34.82 34.82 34.82

500.00 700.00 750.00 800.00

Total-

17,408.00 24,372.00 26,112.00 27,853.00 3,133,305.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

95,960.00

952,754.00

395,253.00

1,689,338.00

Repairing Quantity Calculation for Br. No-255/2 ,Ch-254750 m


Sl. Item No. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 . Wing Wall2
(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 0.9 Rail2 2 0.2 0.175 Kerb2 0.5 0.2 Slab2 7.4 0.65 Dirt wallAbut/PierRaft-

Unit Qty for 2Lane 26.33 13 19.785 23.36 3.95 3.95 3.95 Cm Cm Cm Cm Cm Cm Cm 52.66 1.61 2.77 4.67 38.00 1.28 16.21 9.54 60.67 134.75 151.90 172.20 324.10 8.57 8.57 53.76 53.76

2 2 1

0.25 0.7+1.0 2 1 15.36

0.65 2.414 2.414 3.95

3.95 Cm 1 Cm Total= Cm 2.8 4.0 m3 m3

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

15.5 3.5

3.5 6.15

Total= m3 3 12.8 PCC M1515.66 3.65 0.15 m3 Total= 1 Total=

12.8 RCC M35 (open foundation)-

15.36

3.5

12.40 Reinforcement in foundation-

53.76

100 kg 5376.00 Total= kg 5376.00 Total= Tonne 5.4 2.414 2.41 m3 0.25 Total= m3 14.36 8.45 1.14 23.95

13.5 Substructure(M35)-

2 2

0.7+1.0 2 1.00 0.65

3.5 3.5 3.5

13.6 Reinforcement in Substructure-

23.95

100 Kg 2395.00 Total= Kg 2395.00 Total= Tonne 2.4 0.65 m3 Total= m3 33.67 33.67

14.1 Superstructure RCC (M25)-

3.5

7.4

14.2 Reinforcement in Superstructure-

33.67

80 Kg 2693.60 Total= Kg 2693.60 Total= Tonne 2.69 2 Nos. 4.00

10

14.9 Drainage Spouts complete as


per drawing and Technical specification.

Sl. Item No. No. 11 14.18 Filler joint Providing & fixing 20
mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

3 3 3 3
2 11.5

12 12 12 12 0.3

Unit Qty for 2Lane Nos. 36.00 Nos. 36.00 Nos. 36.00 Nos. 36.00 m3 27.60

12 14.10

13 14.11

11.5

0.3

m3

27.60

14

14.7

23.36

23.36

15

8.22

23.36

46.72

16

16.1

7.5

15.36

115.20

17 16.17 Replacement of Expansion


Joints complete as per drawings.

3 8.5

8.5 15.36 metre

25.50 130.56

18

16.2 Removal of existing asphaltic


wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe. 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery.

19

15

Nos.

30.00

20

Nos.

4.00

Sl. Item No. No. 21 8.51 RPM: Providing relfective


pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 16.28 Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface. 16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

15

Unit Qty for 2Lane Nos. 15.00

22

2 2

0.65
0.7+1.0 2

0.25 3.064 3.064 23.36

sqm sqm sqm sqm

0.33 32.78 3.06 23.36 59.53 139

1 1
Total-

23

sqm 83.558 Each 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no : 255/2 Ch-254750
Item No. 1 Total Quantity 4 Rate in Rs. 5

Particulars/Descrption of items 2 Foundation

Unit 3

Amount (Rs.) 6

1/12.1 Excavation for Structures (Earth work in excavation of


foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

2/12.8

3/12.40

4/13.5

5/13.6

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

Cum

888.78

54.00

47,995.00

Cum Cum

94.05 236.87

6514.00 9030.00

612,660.00 2,138,891.00

tonne

33.33

73279.00

2,442,574.00

Cum

65.52

8120.00

532,023.00

Cum

88.45

9169.00

810,984.00

Item No. 1

Particulars/Descrption of items 2 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Tonne

11.96

73343.00

877,398.00

6/14.1 Furnishing and Placing Reinforced/Prestressed cement

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4 Retro reflectorised Traffic sign:
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

Cum

107.02

10591.00

1,133,449.00

MT

7.31

77554.00

567,230.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

17.28

5200.00

89,856.00

Item Particulars/Descrption of items Unit No. 1 2 3 9/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications. 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 11/Analy HAND RAIL metre sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material metre

Total Rate in Quantity Rs. 4 5 198.56 12993.00

Amount (Rs.) 6 2,579,891.00

46.72 46.72

4170.00 1475.00

194,823.00 68,912.00

23.36

2044.00

47,748.00

Cum Cum,

28.80 2.40

12025.00 5498.00

346,320.00 13,196.00

Each

4.00

10197.00

40,788.00

RM

70.08

160.00

11,213.00

Cum

294.14

1524.00

448,276.00

Item Particulars/Descrption of items No. 1 2 18/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Unit 3 Each

Total Quantity 4 40.00

Rate in Rs. 5 204.00

Amount (Rs.) 6 8,160.00

20/8.51

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

21/15.10

22/15.11

Cum Cum Cum

64.88 147.55

4333.00 7046.00 1485.00

0.00 457,145.00 219,112.00

23/15.9

Cum

198.61

1679.00

333,467.00

Total-

14,126,863.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br no 255/2, Ch-254750 m


Sl. Item No. no. 1 12.1 Earth work or
foundation of structures as per drawings & technical specification including setting out.

Unit

Qty for 2Lane 396.29 11.52 8.63 147.56 54.43 103.68 101.10 65.58 888.78 0.00 27.65 34.56 18.14 13.70 94.05 0.00 184.32 9.00 11.15 32.40 236.87

2 2

15.36 15.36 11.5

21.86 21.86+15.36 2 2

12 0.25 0.25 9 3.25 15.36 1.85 1.5

2.15 1.5 1.5 0.75 0.45 0.45 2.5 2 Total =

m3 3 m 3 m m3 m3 m3 m3 m3 3 m
3

15 21.86 21.86

12.8 PCC M-15 = 12.00 15.36 2 21.86+15.36


2

15.36 15.00 3.25 1

m 0.15 m3 0.15 m3 0.15 m3 13.70 m3 Total= m3

c/wall

12.8

RCC M35(open foundation)

m/wall

2 2 2

12 0.25 0.25 1.2

1 1.5 1.5 3

15.36 12 14.86 4.5 Total=

m3 m3 m3 m3

12.40 Reinforcement in foundation = 25 mm dia 16 mm dia 12 mm dia 12 m/wall mm dia

2 2

80 104

32.8 26.5 10 365 100

kg kg

54.72 kg 2 kg 32.4 kg Total = kg Total = Tonne

20246.91 8710.32 486.40 648.89 3240.00 33332.52 33.33

13.5 Substructure (M35) Dirt wall =


Abutment cap =

Abutment = Pier cap Pier M/wall 6 13.5 Substructure (M20) PCC Wing wall-

2 2 2 1 1 2

0.65 0.7
0.7+1.0 2 0.225 1 0.2+0.45 2

12 12 2.189 1 2.189 3.664

0.25 m3 0.225 m3 12 m3 12 12 3 Total= 1 65.52 m3 m3 m3 3 m

3.90 3.78 44.66 2.70 26.27 7.14 88.45 65.52

13.6 Reinforcement in substuctureDirt wall = 12 mm dia

26.55

kg

283.20

Sl. Item No. no. 12 Abutment cap = 12 12 12 12 32 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 2 2 2 0.78 10 1.85 10 1.85 60 27.3 16 m/wall 2 13.5 86 13.5 86 4.52 16 60 100 2 86

Unit kg kg kg kg kg kg kg 1.2 kg 7.14 kg Total = kg Total = Tonne 53.51 m3

Qty for 2Lane 238.51 240.00 282.84 240.00 282.84 6857.01 776.53 2048.00 714.00 11962.94 11.96 107.02

Pier Cap

Abutment =

14.1 Furnished and placing


reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications.

14.2 Reinforcement in Super


Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification.

3.657 MT

7.31

10 14.18

12

Nos.

36.00

11

8.22

23.36 m

46.72

12

14.7

23.36 m

23.36

13 14.16

23.36 m2

70.08

14

14.4

8.50

23.36 m3

198.56

15

14.9

Nos.

Sl. Item No. no. 16 13.9 Back filling behind Abutment 2 12 4.00
,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. Reinforced cement concrete 2 approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course 2 below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery.

Unit 3.064 m3

Qty for 2Lane 294.14

17 14.11

0.3

4.00

12

m3

28.80

18 14.10

0.15

4.00

2.40

19

13.8

40

Nos.

40

20

8.47

Nos.

Sign board : Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 22 15.11 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall.

21

8.4

17.28

17.28

147.6 m3

147.55

23

15.9 Flore apron :Dry rubble Flooring,


Construcytion of dry rubbl flooring at cross drainage works for relatively less important works.

198.6 m3

198.61

24 15.10 Curtain wall complete as per


drawing and Technical specification. 25 Analys HAND RAIL is rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

1 2

64.88 m3 23.36 m

64.88 46.72

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no -259/1,Ch-258170
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Rate in Rs. Quantity 4 5

Amount (Rs.) 6

Cm Cm

0.00 151.97

356.00 573.00

0.00 87,078.00

I.Ordinary Soil B.Mechanical means


(II) With dewatering

3/12.8

(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

186.13

54.00

10,052.00

Cum Cum

5.61 32.70

6514.00 9030.00

36,521.00 295,305.00

4/12.40

Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications tonne 3.27 73279.00 239,623.00

5/13.5

Item No. 1

Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel reinforcement bar of Fe-500 N/mm2

Unit 3

Total Rate in Rs. Quantity 4 5

Amount (Rs.) 6

Cum

9.07

9169.00

83,156.00

6/13.6

(CRS) Tonne

0.76

73343.00

55,961.00

7/14.1

8/14.2

9/14.18

Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

Cum

26.98

10591.00

285,724.00

tonne

2.16

77554.00

167,381.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

Item No. 1 10/8.22

Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete

Unit 3

Total Rate in Rs. Quantity 4 5

Amount (Rs.) 6

metre metre

35.88 17.94

4170.00 2044.00

149,620.00 36,670.00

Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud

11/14.7

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

2.00 20.00

10197.00 204.00

20,394.00 4,080.00

Each Each

4.00

3500.00 3400.00

13,600.00

Item No. 1 17/8.51

Particulars/Descrption of items 2 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.

Unit 3 Each

Total Rate in Rs. Quantity 4 5 10.00 298.00

Amount (Rs.) 6 2,980.00

18/16.1

Sqm

74.55

78.00

5,815.00

19/16.17 Replacement of Expansion Joints complete as per Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 85 b)16 mm dia re-bar fastners 25% of 85 C)20 mm dia re-bar fastners 25% of 85 d)25 mm dia re-bar fastners 25% of 85 20/16.2

metre Sqm

17.00 84.49

3628.00 59.00

61,676.00 4,985.00

Sqm

20.09

614.00

12,333.00

Each Each Each Each

21.17 21.17 21.17 21.17

500.00 700.00 750.00 800.00

10,584.00 14,817.00 15,875.00 16,934.00 Total- 2,175,567.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br no:259/1,Ch-258170


Sl.N Item o. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 .
Wing Wall(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab1 0.82 Dirt wallAbut/PierRaft-

Unit Qty for 2Lane Cm 0.00 1.24 2.09 3.59 30.45 1.62 2.18 36.91 73.90 151.97 69.65 116.48 186.13 5.61 5.61 32.70 32.70 3270.00 3270.00 3.3 0.00 7.63 1.44 9.07 763.00 763.00 0.76 26.98 26.98 2158.24 2158.24 2.16 2.00 24.00 24.00 24.00 24.00 27.60 27.60

2 2

0.82

9.94

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

9.95 3.5

0.9 10 Cm 0.175 14.915 Cm 0.2 17.94 Cm 9.4 3.95 Cm 0.25 3.95 Cm 0.7+0.94 1.33 Cm 2 3.95 0.94 Cm 2 36.95 Cm Total= Cm 3 3.5 2 m 4.16 4.0 m3 Total= m3 0.15 m3 Total= 0.94 Total= 100 kg Total= kg Total= Tonne 3.50 0.82 Total= 100 Total= Total= 0.82 Total= 80 Total= Total= 1 12 12 12 12 0.3 0.3 m3
3

3 4

12.8 PCC M1512.8 RCC M35 (open foundation)-

10.24 9.94

3.65 3.5

12.40 Reinforcement in foundation-

32.7

13.5 Substructure(M35)2 2
0.7+0.94 2

1.33 3.5 7.63

0.25

13.6 Reinforcement in Substructure-

m Kg Kg
Tonne

8 9

14.1 Superstructure RCC (M25)14.2 Reinforcement in Superstructure-

3.5

9.4 26.978

m3 m3 Kg Kg
Tonne

10 11

14.9 Drainage Spouts complete as per


drawing and Technical specification.

2 2 2 2 2
2 11.5

Nos. Nos. Nos. Nos. Nos. m3 m3

14.18 Filler joint Providing & fixing 20 mm


thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

12 13

14.10 PCC M15 grade levelling course


below approach slab complete as per drawing and technical specification 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification.

4 4

11.5

Sl.N Item o. No. 14 14.7 Construction of RCC Railing of M30


Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.

Unit Qty for 2Lane 17.94 m 17.94

15

17.94 m

35.88

16

7.5

9.94

74.55

17 18

2 8.5

8.5 9.94 metre

17.00 84.49

19

13.8 Providing weep holes in brick


mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery. 8.51 RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 16.28 Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

10

Nos.

20.00

20

Nos.

4.00

21

10

Nos.

10.00

22

0.82 2

2
0.7+0.94 2

0.25 1.33 9.94 9.94

sqm sqm

0.41 2.18 9.34 8.15 20.09 85

0.94 0.82

23

16.53 Providing, placing and fixing in position


Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

sqm sqm Total- sqm 50.8 Each 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no : 259/1 ,Ch-258170
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35

Cum

652.60

54.00

35,241.00

Cum Cum

46.75 167.76

6514.00 9030.00

304,537.00 1,514,873.00

(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

tonne

18.02

73279.00

1,320,167.00

4/13.5

Cum

45.97

8120.00

373,277.00

Cum

37.09

9169.00

340,097.00

5/13.6

Item No.

Particulars/Descrption of items (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure

Unit Tonne

Total Rate in Quantity Rs. 7.87 73343.00

Amount (Rs.) 577,252.00

6/14.1

Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v)80cmm x 45 cm rectangular

Cum

87.14

10591.00

922,900.00

MT

6.08

77554.00

471,219.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

10/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications.

17.28 152.49

5200.00 12993.00

89,856.00 1,981,303.00

Item No.

Particulars/Descrption of items

Unit

Total Quantity

Rate in Rs.

Amount (Rs.)

11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analys HAND RAIL is Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 19/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification metre metre 35.88 35.88 4170.00 1475.00 149,620.00 52,923.00

metre

17.94

2044.00

36,670.00

Cum Cum, Each

28.80 14.40 2.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 20,394.00

RM

53.82

160.00

8,612.00

Cum Each

206.40 40.00

1524.00 204.00

314,554.00 8,160.00

Item No.

Particulars/Descrption of items

Unit

Total Quantity

Rate in Rs.

Amount (Rs.)

20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 22/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 23/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 24/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 25/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

Cum Cum Cum

42.92 97.61

4333.00 7046.00 1485.00

0.00 302,415.00 144,951.00

Cum

91.91

1679.00

154,317.00

Total-

9,623,198.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.259/1 Ch-258170


Sl. Item No. no.

Unit

Qty for 2Lane 336.37 7.46 9.00 97.61 67.10 24.81 66.88 43.38 652.60 0.00 16.28 8.10 22.37 46.75 0.00 119.28 9.00 7.08 32.40 167.76

12.1 Earth work or foundation of


structures as per drawings & technical specification including setting out.

2 2

9.94 0.25 0.25


14.46

15 2
14.46+9.94 2

12 9.94 12 9 0.45 2.26 1.85 1.5

2.82 1.5 1.5 0.75 9.94 0.45 2.5 2

m m3 m3 3 m m3 m3 m m3 Total = m m3 m3 m3 Total=
3 3

14.46 14.46

12.8 PCC M15 11.5 2


14.46+9.44 2

9.44 2.26 0.15

0.15 0.15 9.94

15

12.8

RCC M35(open foundation)

m3 12 0.25 0.25 3 1 1.5 1.5 1.2 9.94 12 9.44 4.5 Total= m3 m3 3 m m3

m/wall

2 2 2

12.40 Reinforcement in foundation 25 mm dia 16 mm dia m/wall

2 2

110 80

12.94 15 100

kg kg 32.4 kg Total = kg Total = Tonne

10983.02 3792.59 3240.00 18015.62 18.02

13.5 Substructure RCC (M35) Dirt wall Abutment cap -

Abutment M/wall-

2 2 2 2

0.82 0.7
0.7+1.0 2 0.2+0.45 2

0.25 12 1.105 3

12 0.225 12 3 Total=

m3 m3 m3

4.92 3.78 22.54 5.85 37.09

13.5 Substructure (M20) PCC Wing wall13.6 Reinforcement in substuctureDirt wall 12 mm dia

45.97 m3

45.97

26.55

Kg

283.20

Sl. Item No. no.

Unit 12 Abutment cap 12 12 20 12 12 mm dia mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 2 M/wall 0.95 10 1.85 2 10 110 2 13.5 86 110 27.3 10 100 3.45 86 Kg Kg Kg Kg Kg 1 Kg 5.85 Kg Total = Kg Total = Tonne 87.14 m3

Qty for 2Lane 290.49 240.00 282.84 3748.15 485.33 1955.56 585.00 7870.57 7.87 87.14

Abutment -

14.1 Furnished and placing


reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical Filler joint Providing &specification. fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing

14.2

6.076

MT

6.08

10 14.18

12

Nos.

24.00

11

8.22

17.94

35.88

12

14.7

17.94

17.94

13 14.16

17.94

m2

53.82

14

14.4 Providing and laying Cement


concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. 14.9 Drainage Spouts complete as per drawing and Technical specification. 13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material.

8.50

17.94

152.49

15 16

1 2 12 4.00

2 2.15

Nos. m3

2.00 206.40

Sl. Item No. no.

Unit 2 0.3 4.00 12 m3

17 14.11 Reinforced cement concrete


approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom shank to the top Sign board : Retroof reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall.

Qty for 2Lane 28.80

18 14.10

0.15

4.00

12

m3 Nos.

14.40

19

13.8

40.00

20

8.47

Nos.

4.00

21

8.4

17.28

17.28

22 15.11

97.61

m3

97.61

23

15.9 Flore apron :Dry rubble Flooring,

91.91

m3

91.91

Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. 24 15.10 Curtain wall complete as per drawing and Technical specification. 25 Analys HAND RAIL is rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

1 2

42.92 17.94

m3 m

42.92 35.88

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-259/2 ,Ch-258380
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

49.24 93.99

356.00 573.00

17,530.00 53,856.00

I.Ordinary Soil B.Mechanical means


(II) With dewatering

3/12.8

(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

144.27

54.00

7,791.00

Cum Cum

5.22 34.79

6514.00 9030.00

33,994.00 314,154.00

4/12.40

Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications

tonne

3.5

73279.00

254,938.00

Item No. 1

Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cum

13.99

9169.00

128,298.00

6/13.6

7/14.1

8/14.2

9/14.18

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper metre plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as metre per drawings and technical specifications with coarse sand and 6% bitumen by weight.

1.40

73343.00

102,534.00

26.98

10591.00

285,724.00

2.16

77554.00

167,381.00

24.00

1640.00

39,360.00

24.00

558.00

13,392.00

24.00

317.00

7,608.00

24.00

17.00

408.00

Item No. 1 10/8.22

Particulars/Descrption of items

Unit 3

2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

35.88 17.94

4170.00 2044.00

149,620.00 36,670.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

2.00 30.00

10197.00 204.00

20,394.00 6,120.00

Each Each

4.00

3500.00 3400.00

13,600.00

Item No. 1 17/8.51

Particulars/Descrption of items 2 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.

Unit 3 Each

Total Quantity 4 10.00

Rate in Rs. 5 298.00

Amount (Rs.) 6 2,980.00

18/16.1

Sqm

74.55

78.00

5,815.00

19/16.17 Replacement of Expansion Joints complete as per Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface. 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 87 b)16 mm dia re-bar fastners 25% of 87 C)20 mm dia re-bar fastners 25% of 87 d)25 mm dia re-bar fastners 25% of 87 20/16.2

metre Sqm

17.00 84.49

3628.00 59.00

61,676.00 4,985.00

Sqm

14.34

614.00

8,803.00

Each Each Each Each

21.84 21.84 21.84 21.84

500.00 700.00 750.00 800.00

Total-

10,921.00 15,290.00 16,382.00 17,474.00 2,281,333.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br.no-259/2,Ch-258380 m


Sl. No. 1 Item No. 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 . Wing Wall2
(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 0.9 Rail2 2 0.2 0.175 Kerb2 0.5 0.2 Slab1 9.4 0.82 Dirt wall2 0.82 0.25 Abut/Pier2 3.95 0.7+1.0 2 Raft-

Unit

Qty for 2Lane 49.24 1.24 2.09 3.59 30.45 1.62 15.75 39.26 93.99 41.79 102.48 144.27 5.22 5.22 34.79 34.79 3479.00 3479.00 3.5 12.56 1.44 13.99 1398.00 1398.00 1.4 26.98 26.98 2158.24 2158.24 2.16 2.00

24.62 10 14.915 17.94 3.95 3.95 2.345 1 Total= 1.2 4.0

Cm Cm Cm Cm Cm Cm Cm Cm Cm m3 m3

9.94 9.95 3.5

3.95 3.5 3.66

12.1

Earth work in or foundation of structures as per drawings & technical specification including setting out.(Upto 3m)PCC M15RCC M35 (open foundation)-

3 4 5

12.8 12.8

9.94 9.94

3.5 3.5 34.79

12.40 Reinforcement in foundation-

Total= m3 0.15 m3 Total= 1 Total= 100 kg Total= kg Total= Tonne 2.345 m3

13.5

Substructure(M35)-

2 2 7 13.6
Reinforcement in Substructure-

0.7+1.0 2

3.15 3.5 13.98

0.25

8 9

14.1 14.2

Superstructure RCC (M25)Reinforcement in Superstructure-

3.5

9.4 26.978

10

14.9

Drainage Spouts complete as per drawing and Technical specification. mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

0.82 Total= m3 100 Kg Kg Total= Total= Tonne 0.82 m3 Total= m3 80 Kg Kg Total= Total= Tonne 2 Nos.

11

14.18 Filler joint Providing & fixing 20

2 2 2 2
2 11.5

12 12 12 12 0.3

Nos. Nos. Nos. Nos. m3

24.00 24.00 24.00 24.00 27.60

12

14.10 PCC M15 grade levelling course


below approach slab complete as per drawing and technical specification

Sl. Item No. No. 13 14.11 Reinforced cement concrete


approach slab including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

Unit
2 11.5

0.3

m3

Qty for 2Lane 27.60

14

14.7

17.94

17.94

15

8.22

17.94

35.88

16

16.1

7.5

9.94

74.55

17

16.17 Replacement of Expansion


Joints complete as per drawings.

8.5

17.00

18

16.2

Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe. Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

8.5

9.94

metre

84.49

19

13.8

15

Nos.

30.00

20

8.47

Nos.

4.00

21

8.51

10

Nos.

10.00

Sl. Item No. No. 22 16.28 Supplying and applying Epoxy


based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

Unit 0.82
2

2
0.7+1.0 2

0.25 2.345 9.94


Total-

Qty for 2Lane sqm 0.41 sqm 3.99 sqm 9.94 14.34 87

23

16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

52.42 0.6

sqm Each

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no: 259/2, Ch-258380
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel Cum

730.30

54.00

39,437.00

47.82 167.76

6514.00 9030.00

311,494.00 1,514,873.00

tonne

15.02

73279.00

1,100,669.00

Cum

67.68

8120.00

549,562.00

Cum

57.80

9169.00

529,950.00

Item No. 1

Total Rate in Quantity Rs. 2 3 4 5 (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne 11.94 73343.00 bar of Fe-500 N/mm2 Super Structure Particulars/Descrption of items Unit
in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Amount (Rs.) 6 875,971.00

6/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

Cum

87.14

10591.00

922,900.00

MT

6.08

77554.00

471,219.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

9/14.4 Providing and laying Cement concrete wearing coat M- m3 30 grade including reinforcement complete as per drawing and Technical Specifications.

17.28 152.49

5200.00 12993.00

89,856.00 1,981,303.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

35.88 35.88

4170.00 1475.00

149,620.00 52,923.00

metre

17.94

2044.00

36,670.00

Cum Cum, Each

28.80 14.40 2.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 20,394.00

RM

53.82

160.00

8,612.00

Cum

303.84 40.00

1524.00 204.00

463,053.00 8,160.00

18/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

Item No.

Particulars/Descrption of items

Unit 3

1 2 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 21/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

Cum Cum Cum

49.39 112.32

4333.00 7046.00 1485.00

0.00 348,002.00 166,796.00

Cum

107.16

1679.00

179,922.00

Total- 10,321,246.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.259/2,Ch-258380


Sl. Item no. No

Unit
Earth work or foundation of structures as per drawings & technical specification including setting out.

Qty for 2Lane 375.73 7.46 9.00 112.32 67.10 31.82 76.96 49.92 730.30 0.00 16.28 9.17 22.37 47.82 0.00 119.28 9.00 7.08 32.40 167.76

12.1

2 2

9.94 0.25 0.25


16.64

12 9.94 12 9 0.45 2.66 1.85 1.5

3.15 1.5 1.5 0.75 9.94 0.45 2.5 2 Total =

m m3 m3 m3 3 m m3 m3 3 m

15 2 16.64+9.94
2

16.64 16.64

12.8

PCC M-15 = 11.5 2 16.64+9.94


2

9.44 2.3 0.15

0.15 0.15 9.94

15

Total= 3 12.8
RCC M35(open foundation)

m3 12 0.25 0.25 3 1 1.5 1.5 1.2 9.94 12 9.44 4.5 Total= m3 m3 m3

m/wall

2 2 2

12.40

Reinforcement in foundation = 25 mm dia 16 mm dia m/wall

2 2

12.94 80

80 15 100

kg kg 32.4 kg Total = kg Total = Tonne

7987.65 3792.59 3240.00 15020.25 15.02

13.5

Substructure (M35) RCC Dirt wall


Abutment cap

Abutment M/wall

2 2 2 2

0.82 0.7
0.7+1.0 2 0.2+0.45 2

0.25 12 2.12 3

12 0.225 12 3 Total=

m3 m3 3 m m3

4.92 3.78 43.25 5.85 57.80

13.5

Substructure (M20) PCC Wing wallReinforcement in substuctureDirt wall = 12 mm dia 12 mm dia

67.68

m3

67.68

13.6

2 2

6 0.95

26.55 2

86.00

kg kg

283.20 290.49

Sl. Item no. No Abutment cap =

Unit 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 10 1.85 2 15 15 m/wall 13.5 86 100 27.3 100 100 4.45 kg kg kg kg 1 kg 5.85 kg Total = kg Total = Tonne 87.14 m3

Qty for 2Lane 240.00 282.84 6867.28 728.00 2666.67 585.00 11943.48 11.94 87.14

Abutment =

14.1

14.2

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing 2 wall and Return Wall complete as per drawing and technical specification with Granular Material. Reinforced cement concrete 2 approach slab including reinforcement and formwork complete as per drawing and Technical

6.076

MT

6.08

10

14.18

12

Nos.

24.00

11

8.22

17.94

35.88

12

14.7

17.94

17.94

13

14.16

17.94

m2

53.82

14

14.4

8.50

17.94

m3

152.49

15 16

14.9 13.9

1 12 4.00

2 3.165

Nos. m3

2.00 303.84

17

14.11

0.3

4.00

12

m3

28.80

Sl. Item no. No

Unit
PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Sign board : Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification. Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

18

14.10

0.15

4.00

12

m3

Qty for 2Lane 14.40

19

13.8

40

Nos.

40.00

20

8.47

Nos.

4.00

21

15.11

112.32

112.32

22

8.4

17.28

m2

17.28

23

15.9

107.16

m3

107.16

24

15.10

1 2

49.39 17.94

49.39 35.88

25 Analysis HAND RAIL


rate

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-259/3 ,Ch-258590 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

92.14 352.71

356.00 573.00

32,802.00 202,102.00

2/12.1

I.Ordinary Soil B.Mechanical means


(II) With dewatering

3/12.8

(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

419.50

54.00

22,653.00

Cum Cum

15.11 151.10

6514.00 9030.00

98,424.00 1,364,388.00

4/12.40

Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 tonne 15.11 73279.00 1,107,210.00

Item No. 1 5/13.5

Particulars/Descrption of items 2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cum

61.51

9169.00

564,008.00

6/13.6

Tonne

6.15

73343.00

451,133.00

7/14.1

Cum

80.93

10591.00

857,172.00

8/14.2

tonne

6.47

77554.00

502,141.00

9/14.18

metre

48.00

1640.00

78,720.00

metre

48.00

558.00

26,784.00

Item No. 1

Particulars/Descrption of items 2 (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete Construction of RCC railing of M30 Grade insitu with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.

Unit 3 metre

Total Quantity 4 48.00

Rate in Rs. 5 317.00

Amount (Rs.) 6 15,216.00

metre

48.00

17.00

816.00

10/8.22

11/14.7

metre metre

73.56 36.78

4170.00 2044.00

306,746.00 75,179.00

12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Cum Cum 27.60 27.60 12025.00 5498.00 331,890.00 151,745.00

Each Each

6.00 30.00

10197.00 204.00

61,182.00 6,120.00

Item No. 1 16/8.47

Particulars/Descrption of items 2 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

17/8.51

Each Each Each

4.00 18.00

3500.00 3400.00 298.00

13,600.00 5,364.00

18/16.1

Sqm

215.85

78.00

16,837.00

19/16.17 Replacement of Expansion Joints complete as per Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 272 b)16 mm dia re-bar fastners 25% of 272 C)20 mm dia re-bar fastners 25% of 272 d)25 mm dia re-bar fastners 25% of 272 20/16.2

metre Sqm

34.00 244.63

3628.00 59.00

123,352.00 14,434.00

Sqm

62.65

614.00

38,469.00

Each Each Each Each

68.10 68.10 68.10 68.10

500.00 700.00 750.00 800.00

Total-

34,053.00 47,673.00 51,079.00 54,484.00 6,655,776.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Item No. 1

Particulars/Descrption of items 2

Unit 3

Total Rate in Amount (Rs.) Quantity Rs. 4 Executive 5 Engineer, PWD 6 Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br No.259/3 Ch-258590 m


Sl.No 1 Item No. 2.4 Unit Qty for 2Lane
Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20. Wing Wall2 (B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 0.9 Rail2 2 0.2 0.175 Kerb2 0.5 0.2 Slab3 0.82 9.4 Dirt wall2 0.82 0.25 Abut/Pier2 0.7+1.5 2 4.5

46.07 20 31.55 36.78 3.95 3.95 3.95 3.95 3.95 Total= 3.15 4.0 Total= 0.15 Total= 1.5 Total= 100 Total= Total= 4.541 3.15 0.82 Total= 100 Total= Total= 0.82 Total= 80 Total= Total= 2 12 12 12 12 0.3

Cm Cm Cm Cm Cm Cm Cm Cm Cm Cm 3 m 3 m m3 m3

92.14 2.48 4.42 7.36 91.34 1.62 39.11 35.87 170.52 352.71 317.30 102.20

2
Raft-

1 28.78 28.78 3.5

4.541 1.5 3.5 3.65

12.1

Earth work in or foundation of structures as per drawings & technical specification including setting out.(Upto 3m)PCC M15RCC M35 (open foundation)-

3 4 5

12.8 12.8

28.78 28.78

3.5 3.5 151.095

12.40 Reinforcement in foundation-

13.5

Substructure(M35)-

2 2 2

0.7+1.5 2
1.00

3.15 4.541 3.5 61.51

419.50 15.11 15.11 151.10 151.10 kg 15109.50 kg 15109.50 Tonne 15.11 31.47 m3 m3 Kg Kg
Tonne

0.25

13.6

Reinforcement in Substructure-

8 9

14.1 14.2

Superstructure RCC (M25)Reinforcement in Superstructure-

3.5

9.4 80.934

m3 m3 Kg Kg
Tonne

10 11

12

13

14.9 Drainage Spouts complete as per drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification.

3 4 4 4 4
2 11.5

Nos. Nos. Nos. Nos. Nos. m3

28.61 1.44 61.51 6151.00 6151.00 6.15 80.93 80.93 6474.72 6474.72 6.5 6.00 48.00 48.00 48.00 48.00 27.60

11.5

0.3

m3

27.60

Sl.No 14

15

16

17 18

19

Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe,

Item No. 14.7

36.78

Unit Qty for 2Lane m 36.78

36.78

73.56

7.5

28.78

215.85

4 8.5

8.5 28.78 metre

34.00 244.63

15

Nos.

30.00

20

8.47

Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

Nos.

4.00

21

8.51

18

Nos.

18.00

22

16.28 Supplying and applying Epoxy


based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

0.82
2

2
0.7+1.5 2

0.25 4.541 4.541 1.5

sqm sqm sqm sqm

0.41 9.99 9.08 43.17 62.65

1 28.78

Total- sqm

Sl.No 23

Item No.
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

Unit Qty for 2Lane 163.45 Each 272 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no : 259/3 , Ch-258590
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35

Cum

2221.38

54.00

119,955.00

Cum Cum

248.18 580.65

6514.00 9030.00

1,616,649.00 5,243,270.00

(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

tonne

61.57

73279.00

4,511,428.00

Cum

194.89

8120.00

1,582,507.00

Cum

242.08

9169.00

2,219,617.00

5/13.6

Item No. 1

Particulars/Descrption of items

Unit

2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

45.96

73343.00

3,370,806.00

6/14.1 Furnishing and Placing Reinforced/Prestressed cement

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

Cum

261.42

10591.00

2,768,700.00

MT

18.23

77554.00

1,413,655.00

metre

48.00

1640.00

78,720.00

metre

48.00

558.00

26,784.00

metre

48.00

317.00

15,216.00

metre

48.00

17.00

816.00

17.28

5200.00

89,856.00

Item No.

Particulars/Descrption of items

Unit

1 2 3 10/14.4 Providing and laying Cement concrete wearing m3 coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing metre metre

Total Rate in Quantity Rs. 4 5 312.63 12993.00

Amount (Rs.) 6 4,062,002.00

77.56 73.56

4170.00 1475.00

323,426.00 108,501.00

metre

36.78

2044.00

75,179.00

Cum Cum,

28.80 14.40

12025.00 5498.00

346,320.00 79,172.00

Each

6.00

10197.00

61,182.00

RM

110.34

160.00

17,655.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 19/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
22/15.10 Curtain wall complete as per drawing and Technical

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cum Each

514.66 40.00

1524.00 204.00

784,336.00 8,160.00

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Cum Cum Cum

119.25 271.21

4333.00 7046.00 1485.00

0.00 840,236.00 402,747.00

Cum

371.14

1679.00

623,145.00

Total-

30,803,640.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.259/3,Ch-258590


Sl. No. 1 Item no. 12.1
Earth work or foundation of structures as per drawings & technical specification including setting out.

Unit Qty for 2Lane 28.78 28.78 11.5


40.18 40.18+28.78 2

2 2 2

12 0.25 0.25 9 5.7 28.78 1.85 1.5

3.66 1.5 1.5 0.75 0.45 0.4 2.5 2 Total =

m3 m3 m3 3 m 3 m m m3 m3
3

1264.02 21.59 8.63 271.22 176.88 172.68 185.83 120.54 2221.38 0.00 51.80 64.76 117.92 13.70 248.18

15 40.18 40.18

12.8

PCC M-15 = 12 28.78 2 c/wall


28.78+40.18 2

28.78 15 5.7 1

0.15 0.15 0.15 13.7 Total=

m3 m3 m3 m3

12.8

RCC M35(open foundation)

m3 12 0.25 0.25 1.2 1.5 1.5 1.5 3 28.78 12 28.28 4.5 Total= m3 m3 m
3

0.00 518.04 9.00 21.21 32.40 580.65

m/wall

2 2 2

12.40

Reinforcement in foundation = 28 mm dia 16 mm dia 12 mm dia 12 m/wall mm dia

2 2

160 192

31.28 13.5 544 10 100

2 81.5

kg kg kg kg

48441.52 8192.00 967.11 724.44

32.4 kg 3240.00 Total = kg 61565.08 Total = Tonne 61.57

13.5

Substructure (M35) Dirt wall


Abutment cap

Abutment Pier Cap Pier M/wall 6 13.5 Substructure (M20) PCC Wing wall-

2 2 2 2 2 2

0.82 0.7 0.7+1.5 2 0.225


4.316 0.2+0.45 2

12 12 4.316 12 12 5.36

0.25 0.225 12 1 1 3 Total=

m 3 m m3 m3 m3 3 m

4.92 3.78 113.94 5.40 103.58 10.45 242.08

194.89

m3

194.89

Sl. No. 7

Item no. 13.6 Reinforcement in substuctureDirt wall = 12 mm dia 12 mm dia Abutment cap = 12 12 Abutment = 28 12 12 12 12 28 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia

Unit Qty for 2Lane 2 2 2 2 2 2 2 2 2 2 2 6 0.78 10 1.85 2 2 120 10 1.85 2 29 80 m/wall 26.55 2 13.5 86 120 29 29 13.5 86 80 27.3 29 100 7.14 7.14 27.3 1.25 Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg 283.20 238.51 240.00 282.84 16585.96 1407.47 7733.33 240.00 282.84

86

Pier Cap

Pier

14.1

14.2

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification.

11057.30 1407.47 1.25 5155.56 10.45 1045.00 Total = 45959.48 Total = Tonne 45.96 3 87.14 261.42 m

6.076

MT

18.23

10

14.18

12

Nos.

48.00

11

8.22

38.78

77.56

12

14.7

36.78

36.78

13

14.16

36.78

m2

110.34

14

14.4

36.78

8.5

m3

312.63

15

14.9

Nos.

Sl. No. 16

Item no. 13.9


Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification. HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

Unit Qty for 2Lane 2 12 4.00 5.361 m3 514.66

17

14.11

0.3

4.00

12

m3

28.80

18

14.10

0.15

4.00

12

m3

14.40

19

13.8

40

Nos.

40

20

8.47

Nos.

21

8.4

17.28

m2

17.28

22

15.11

271.21

m3

271.21

23

15.9

371.14

m3

371.14

24 25

15.10
Analysis rate

1 2

119.25 36.78

119.25 73.56

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-260/1, Ch-259015 m
Total Quantity 4 Rate in Rs. 5

Item No. 1 1/2.4

Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Amount (Rs.) 6

Cm Cm

64.12 199.50

356.00 573.00

22,827.00 114,312.00

2/12.1

I.Ordinary Soil B.Mechanical means


(II) With dewatering

3/12.8

(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications

Cum

262.93

54.00

14,199.00

Cum Cum

11.21 74.76

6514.00 9030.00

73,048.00 675,083.00

4/12.40

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m

7.48

73279.00

547,834.00

Item No. 1

Particulars/Descrption of items

Unit

6/13.6

7/14.1

8/14.2

9/14.18

2 3 Case II : With Batching plant, Transit Mixer and Cum concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate metre in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per metre drawings and technical specifications with coarse sand and 6% bitumen by weight. Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre

Total Quantity 4 25.65

Rate in Rs. 5 9169.00

Amount (Rs.) 6 235,210.00

2.57

73343.00

188,125.00

65.52

10591.00

693,923.00

5.24

77554.00

406,508.00

36.00

1640.00

59,040.00

36.00

558.00

20,088.00

36.00

317.00

11,412.00

36.00

17.00

612.00

10/8.22

58.72

4170.00

244,863.00

Item No. 1 11/14.7

Particulars/Descrption of items

Unit

2 3 Construction of RCC railing of M30 Grade in-situ with metre 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 13/14.10 PCC M15 grade levelling course below approach slab Cum complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Each Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 17/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat Sqm including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per drawings. metre 16/8.47 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned 20/16.2 Sqm

Total Quantity 4 29.36

Rate in Rs. 5 2044.00

Amount (Rs.) 6 60,012.00

27.60 27.60 4.00 40.00

12025.00 5498.00 10197.00 204.00

331,890.00 151,745.00 40,788.00 8,160.00

4.00 14.00

3500.00 3400.00 298.00

13,600.00 4,172.00

160.20

78.00

12,496.00

25.50 181.56

3628.00 59.00

92,514.00 10,713.00

Sqm

29.45

614.00

18,085.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 190 b)16 mm dia re-bar fastners 25% of 190 C)20 mm dia re-bar fastners 25% of 190 d)25 mm dia re-bar fastners 25% of 190

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Each Each Each Each

47.43 47.43 47.43 47.43

500.00 700.00 750.00 800.00

23,715.00 33,201.00 35,572.00 37,944.00 Total- 4,181,691.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br.no-260/1,Ch-259015 m


Sl. No. 1 Item No. 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 Wing Wall2
(B) Prestressed/ Reinforced cement grade M-20 & above Post 2 0.275 0.25 0.9 Rail2 2 0.2 0.175 Kerb2 0.5 0.2 Slab2 10.4 0.9 Dirt wall2 0.9 0.25 Abut/Pier2 3.95 0.7+1.0 2

Unit

Qty for 2Lane 64.12 1.98 3.49 5.87 73.94 1.78 19.01 11.18 82.24 199.50 160.73 102.20 262.93 11.21 11.21 74.76 74.76 7476.00 7476.00 7.48 15.16 8.92 1.58 25.65 2565.00 2565.00 2.57 65.52 65.52 5241.60 5241.60 5.24 4.00

32.06 16 24.96 29.36 3.95 3.95 2.831 2.831 3.85 Total= 2.15 4.0 Total= 0.15 Total= 1 Total= 100 Total= Total= 2.831 2.83 0.90 Total= 100 Total= Total= 3.5 Total= 80 Total= Total= 2

Cm Cm Cm Cm Cm Cm Cm Cm Cm Cm

1
Raft-

1 21.36 21.36 3.5

3.95 1 3.5 3.65

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

m3 m3 m3 m3

3 4 5

12.8 PCC M1512.8 RCC M35 (open foundation)12.40 Reinforcement in foundation-

21.36 21.36

3.5 3.5 74.76

kg kg
Tonne

13.5

Substructure(M35)-

2 1 2

0.7+1.0 2
1.00

3.15 3.15 3.5 25.65

m3 m3 Kg Kg
Tonne

0.25

13.6 Reinforcement in Substructure-

8 9

14.1 Superstructure RCC (M25)14.2 Reinforcement in Superstructure-

0.9

10.4 65.52

m3 m3 Kg Kg
Tonne

10

14.9 Drainage Spouts complete as


per drawing and Technical specification.

Nos.

11

14.18 Filler joint Providing & fixing 20


mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification

3 3 3 3
2 11.5

12 12 12 12 0.3

Nos. Nos. Nos. Nos. m3

36.00 36.00 36.00 36.00 27.60

12

Sl. Item No. No. 13 14.11 Reinforced cement concrete


approach slab including reinforcement and formwork complete as per drawing and Technical specification.

Unit
2 11.5

0.3

m3

Qty for 2Lane 27.60

14

14.7 Construction of RCC Railing of


M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe,

29.36

29.36

15

29.36

58.72

16

7.5

21.36

160.20

17

8.5

25.50

18

8.5

21.36

metre

181.56

19

20

Nos.

40.00

20

8.47 Providing 'Sparkle Solar Road


Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery.

Nos.

4.00

21

8.51 RPM: Providing relfective


pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

14

Nos.

14.00

Sl. Item No. No. 22 16.28 Supplying and applying Epoxy


based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

Unit 0.9
2

2
0.7+1.0 2

0.25 2.831 2.831 1

sqm sqm sqm sqm

Qty for 2Lane 0.45 4.81 2.83 21.36 29.45 190

1 21.36

23

16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

Total- sqm 113.83 Each 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no: 260/1,Ch-259015
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of foundation
of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum

1473.56

54.00

79,573.00

130.64 441.90

6514.00 9030.00

850,989.00 3,990,357.00

3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

29.14

73279.00

2,135,459.00

79.76

8120.00

647,652.00

101.13

9169.00

927,270.00

Item No. 1

Total Rate in Amount (Rs.) Quantity Rs. 2 3 4 5 6 (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne 26.47 73343.00 1,941,433.00 bar of Fe-500 N/mm2 Super Structure Particulars/Descrption of items Unit
in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

6/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

Cum

212.80

10591.00

2,253,765.00

MT

14.09

77554.00

1,093,047.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

10/14.4 Providing and laying Cement concrete wearing coat M- m3 30 grade including reinforcement complete as per drawing and Technical Specifications.

17.28 249.56

5200.00 12993.00

89,856.00 3,242,534.00

Item Particulars/Descrption of items No. 1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. (i) 'M 20 grade concrete 12/Anal HAND RAIL ysis Providing and fixing hand rail over the crash barrier Rate consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

58.72 58.72

4170.00 1475.00

244,863.00 86,612.00

metre

29.36

2044.00

60,012.00

Cum Cum, Each

28.80 14.40 4.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 40,788.00

RM

88.08

160.00

14,093.00

(A) Granular material Cum 19/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

358.08 30.00

1524.00 204.00

545,714.00 6,120.00

Item Particulars/Descrption of items No. 1 2 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

Cum Cum Cum

87.14 198.18

4333.00 7046.00 1485.00

0.00 613,989.00 294,298.00

Cum

235.47

1679.00

395,355.00

Total- 20,084,023.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No. 260/1 Ch- 259015 m


Sl. Item no. No. 1 12.1 Earth work or foundation
of structures as per drawings & technical specification including setting out.

Unit

Qty for 2Lane 807.41 16.02 8.63 198.18 91.30 128.16 135.79 88.08 1473.56

2 2 2

21.36 21.36 11.5


29.36 29.36+21.36 2

12 0.25 0.25 9 4 21.36 1.85 1.5

3.15 1.5 1.5 0.75 0.45 0.4 2.5 2 Total =

m m3 m3 3 m m3 m3 3 m m3 m3

15 29.36 29.36

12.8

PCC M-15 12 21.36 2 29.36+21.36


2

21.36 15 4 1

0.15 0.15 0.15 13.7

m3 m3 m3 m3
3

38.45 48.06 30.43 13.70 130.64 0.00 384.48 9.00 16.02 32.40 441.90

c/wall

Total= m 3 12.8
RCC M35(open foundation)

m3 12 0.25 0.25 1.2 1.5 1.5 1.5 3.00 21.36 12 21.36 4.5 Total= m3 m3 3 m m3

M/wall

2 2 2

12.40

Reinforcement in foundation = 25 mm dia 16 mm dia 12 mm dia 12 m/wall mm dia

2 2

100 155

23.16 13.5 445 10 100

2 70.5

kg kg kg kg

17870.37 6613.33 791.11 626.67

32.4 kg 3240.00 Total = kg 29141.48 Total = Tonne 29.14

13.5

Substructure (M35) Dirt wall


Abutment cap

Abutment Pier cap Pier M/wall

2 2 2 0

0.9 0.225 0.7+1.0 2 0.9 1

0.25 12 2.606 0.225 2.606 3.73

12 0.7 12 12 12 3 Total=

m 3 m m3 m3 m3 3 m m3

5.40 3.78 53.16 0.24 31.27 7.27 101.13

0.2+0.45 2

Sl. Item no. No. 6 13.5 Substructure (M20) PCC Wing wallReinforcement in substuctureDirt wall 12 mm dia 12 mm dia
Abutment cap

Unit

Qty for 2Lane

79.76 m3

79.76

13.6

2 2 2 2 2 2 2 2 2 2

6 0.78 10 1.85 2 98 98 98 18 98 m/wall

26.55 2 13.5 86 98 27.3 18 4.95 27.3 18 100

86

kg kg kg kg

283.20 238.51 240.00 282.84 7486.11 4756.27 3920.00

12 12 25 12 12 25 12 12

mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia

Abutment

4.95 1.25

kg kg kg

Pier

kg 3743.06 kg 873.60 1.25 kg 3920.00 7.27 kg 727.00 Total = kg 26470.58 Total = Tonne 26.47 106.40 m3 212.80

14.1

14.2

10

14.18

11

8.22

12

14.7

13

14.16

14

14.4

15

14.9

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification.

7.047

MT

14.09

12

Nos.

36.00

29.36

58.72

29.36

29.36

29.36

88.08

8.50

29.36

m3

249.56

Nos.

Sl. Item no. No. 16 13.9 Back filling behind Abutment ,Wing
wall and Return Wall complete as per drawing and technical specification with Granular Material. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical PCC M15 grade levelling course below approach slab complete as per drawing and technical specification

Unit 2 12 4.00 3.73 m3

Qty for 2Lane 358.08

17

14.11

0.3

4.00

12

28.80

18

14.10

0.15

4.00

12

14.40

19

20

21

22

23

24 25

Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm Sign board : Retro reflectorised 8.4 Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per 15.11 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg 15.9 Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. 15.10 Curtain wall complete as per drawing and Technical specification. Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts,

13.8

Nos.

30

Nos.

17.28

17.28

198.18 m3

198.18

235.47 m3

235.47

1 2

87.14 29.36

m3 m

87.14 58.72

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-260/2, Ch-259230 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

100.76 207.60

356.00 573.00

35,871.00 118,954.00

2/12.1 Excavation for Structures (Earth work in excavation of

I.Ordinary Soil B.Mechanical means


(II) With dewatering

(i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 4/12.40 Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications

Cum

386.49

54.00

20,871.00

Cum Cum

8.57 80.64

6514.00 9030.00

55,851.00 728,180.00

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35

8.06

73279.00

590,922.00

Item No. 1

Particulars/Descrption of items 2 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

Unit 3 Cum

Total Quantity 4 61.62

Rate in Rs. 5 9169.00

Amount (Rs.) 6 564,971.00

6/13.6

Tonne

6.16

73343.00

451,867.00

7/14.1

Cum

33.15

10591.00

351,113.00

8/14.2

tonne

2.69

77554.00

208,900.00

9/14.18

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

Item No.

Particulars/Descrption of items

Unit

1 2 3 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 13/14.10 PCC M15 grade levelling course below approach slab Cum complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Each Each

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

46.72 23.36

4170.00 2044.00

194,823.00 47,748.00

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

4.00 50.00

10197.00 204.00

40,788.00 10,200.00

Each Each Each

4.00 15.00

3500.00 3400.00 298.00

13,600.00 4,470.00

Item No.

Particulars/Descrption of items

Unit 3 Sqm

1 2 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per drawings. 20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 192 b)16 mm dia re-bar fastners 25% of 192 C)20 mm dia re-bar fastners 25% of 192 d)25 mm dia re-bar fastners 25% of 192

Total Quantity 4 115.20

Rate in Rs. 5 78.00

Amount (Rs.) 6 8,986.00

metre Sqm

25.50 130.56

3628.00 59.00

92,514.00 7,704.00

Sqm

52.65

614.00

32,325.00

Each Each Each Each

47.93 47.93 47.93 47.93

500.00 700.00 750.00 800.00

Total-

23,967.00 33,554.00 35,950.00 38,347.00 4,287,263.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br.no :260/2 ,Ch-259230 m


Sl. Item No. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20
Wing Wall(B) Prestressed/ Reinforced cement grade M-20 & above Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab0.65 2 Dirt wall0.25 2 Abut/Pier0.7+1.5 2

Unit Qty for 2Lane 2 0.9 0.175 0.2 7.4 0.65 5.4 5.4 3.95 3.5 6.15 50.38 13 19.785 23.36 3.95 3.95 3.95 3.95 1.5 Total= 3.95 4.0 Total= 0.15 Total= 1.5 Total= 100 Total= Total= 5.4 5.40 0.25 Total= 100 Total= Total= 0.64 Total= 80 Total= Total= 2 12 12 12 12 0.3 m3 m3 Kg Kg
Tonne

Cm Cm Cm Cm Cm Cm Cm Cm Cm Cm m3 m3 m3 m3

100.76 1.61 2.77 4.67 38.00 1.28 46.93 21.33 91.01 207.60 214.29 172.20 386.49 8.57 8.57 80.64 80.64 8064.00 8064.00 8.06 41.58 18.90 1.14 61.62 6161.00 6161.00 6.16 33.15 33.15 2693.60 2693.60 2.69 4.00 36.00 36.00 36.00 36.00 27.60

1
Raft-

2 1 15.36 15.5 3.5

12.1 Earth work in or foundation of structures


as per drawings & technical specification including setting out.(Upto 3m)-

3 4 5

12.8 PCC M1512.8 RCC M35 (open foundation)12.40 Reinforcement in foundation-

15.66 15.36

3.65 3.5 80.64

kg kg
Tonne

13.5 Substructure(M35)-

2 2

0.7+1.5 2
1.00

3.5 3.5 3.5 61.61

0.65

13.6 Reinforcement in Substructure-

8 9

14.1 Superstructure RCC (M25)14.2 Reinforcement in Superstructure-

3.5

7.4 33.67

m3 m3 Kg Kg
Tonne

10

14.9 Drainage Spouts complete as per

2 3 3 3 3 4

Nos. Nos. Nos. Nos. Nos. m3 m3

drawing and Technical specification. 11 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

12 14.10 PCC M15 grade levelling course


below approach slab complete as per drawing and technical specification

11.5

13 14.11 Reinforced cement concrete approach


slab including reinforcement and formwork complete as per drawing and Technical specification.

11.5

0.3

27.60

Sl. Item No. No. 14 14.7 Construction of RCC Railing of M30


Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete.

23.36

Unit Qty for 2Lane m 23.36

15

23.36

46.72

16

16.1 Removal of existing cement concrete

7.5

15.36

115.20

wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 17 16.17 Replacement of Expansion Joints complete as per drawings. 18 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.

3 8.5

8.5 15.36 metre

25.50 130.56

19

13.8 Providing weep holes in brick


mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery.

25

Nos.

50.00

20

Nos.

4.00

21

8.51 RPM: Providing relfective pavement

15

Nos.

15.00

marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 22 16.28 Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

2
2

0.65
0.7+1.5 2

0.25 5.4 5.4 23.36

sqm sqm sqm sqm

0.33 11.88 5.40 35.04 52.65 192

1 1.5

Total- sqm

23 16.53 Providing, placing and fixing in position


Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

115.04 Each 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no : 260/2, Ch-259230,
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Rate in Quantity Rs. 4 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

1127.00

54.00

60,858.00

Cum Cum

118.09 329.03

6514.00 9030.00

769,264.00 2,971,096.00

3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Cum Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2

38.23

73279.00 2,801,450.00

394.25

8120.00

3,201,310.00

222.07

9169.00

2,036,137.00

46.45

73343.00 3,406,448.00

Item No. 1

Particulars/Descrption of items 2 Super Structure


Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Unit 3

Total Rate in Quantity Rs. 4 5

Amount (Rs.) 6

6/14.1

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

Cum

107.02

10591.00 1,133,449.00

MT

7.31

77554.00

567,230.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

10/14.4 Providing and laying Cement concrete wearing coat M-30 m3 grade including reinforcement complete as per drawing and Technical Specifications.

17.28 198.56

5200.00 89,856.00 12993.00 2,579,891.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

Total Rate in Quantity Rs. 4 5

Amount (Rs.) 6

B. M 40 grade concrete metre 12/Analys HAND RAIL metre is Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineerin-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 15/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical Each specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing RM 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum 19/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

46.72 46.72

4170.00 1475.00

194,823.00 68,912.00

23.36

2044.00

47,748.00

28.80 14.40 4.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 40,788.00

70.08

160.00

11,213.00

580.80 80.00

1524.00 204.00

885,140.00 16,320.00

Item No.

Particulars/Descrption of items

Unit

1 2 3 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures a) Bi-directional Stud Each b) Uni-directional Stud Each 21/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
22/15.10 Curtain wall complete as per drawing and Technical

Total Rate in Quantity Rs. 4 5

Amount (Rs.) 6

4.00

3500.00 3400.00 298.00

13,600.00 0.00

specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Cum Cum Cum

83.34 189.54

4333.00 7046.00 1485.00

0.00 587,214.00 281,467.00

Cum

228.00

1679.00

382,812.00

Total- 22,663,670.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.260/2 , Ch-259230


Sl. Item No no. . 1 12.1 Earth work or foundation of
structures as per drawings & technical specification including setting out.

Unit

Qty for 2Lane 488.45 11.52 8.63 194.81 126.56 103.68 106.78 86.58 1127.00

2 2

15.36 15.36 11.5

28.86 2 28.86+15.36 2

12 0.25 0.25 9 6.36 15.36 1.85 1.5

2.65 1.5 1.5 0.75 0.45

m m3 m3 3 m m3

15 28.86 28.86

0.45 m3 3 2 m 2 m3 Total =

12.8 PCC M-15 12 15.36 2 28.86+15.36


2

15.36 15 6.36 1

0.15 0.15 0.15 13.7 Total=

m3 m3 m3 m3

27.65 34.56 42.19 13.70 118.09

c/wall

12.8

RCC M35(open foundation)

m3 12 0.25 0.25 1.2 1.5 1.5 1.5 3 15.36 12 14.86 4.5 Total= m3 m3 3 m m3 276.48 9.00 11.15 32.40 329.03

m/wall

2 2 2

12.40 Reinforcement in foundation = 25 mm dia 16 mm dia 12 mm dia 12 m/wall mm dia

2 2

100 104

32.8 26 10 365 100

54.72 2

kg kg kg kg

25308.64 8545.98 486.40 648.89

32.4 kg 3240.00 Total = kg 38229.91 Total = Tonne 38.23 0.25 0.225 12 12 12 3 Total= m m3 3 m m3 m3 3 m
3

13.5 Substructure (M35) Dirt wall


Abutment cap

Abutment Pier cap Pier M/wall

2 2 2 1 1 2

0.65 0.7 0.7+1.5 2 0.225


1 0.2+0.45 2

12 12 5.175 1 5.175 6.65

3.90 3.78 136.62 2.70 62.10 12.97 222.07 394.25

13.5

Substructure (M20) PCC Wing wall-

394.25 m3

Sl. Item No no. . 7 13.6 Reinforcement in substuctureDirt wall 12 mm dia 12 mm dia


Abutment cap

Unit

Qty for 2Lane 283.20 238.51 240.00 282.84 240.00 282.84 20859.26 1698.67 8400.00

2 2 2 2 2 2 2 2 2 2 2 2

6 0.78 10 1.85 10 1.85 2 27.3 35 60 27.3 35 m/wall

26.55 2 13.5 86.00 13.5 86.00 100 35 100 8.25 35 60 100

86

kg kg kg kg kg kg

12 12 12 12 32 12 12 32 12 12

mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia

Pier cap

Abutment

8.25 1.35

kg kg kg

Pier

14.1 Furnished and placing


reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete.

kg 6257.78 kg 1698.67 1.25 kg 4666.67 12.97 kg 1297.00 Total = kg 46445.43 Total = Tonne 46.45 53.51 m3 107.02

14.2

3.657

MT

7.31

10 14.18 Filler joint Providing & fixing 20 mm

12

Nos.

36.00

11

8.22

23.36

46.72

12

14.7 Construction of RCC Railing of M30


Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing

23.36

23.36

13

23.36

70.08

14

14.4 Providing and laying Cement concrete


Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.

8.50

23.36

m3

198.56

Sl. Item No no. . 15 14.9 Drainage Spouts complete as per 16 13.9


drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material.

Unit 2 2 12 4.00 2 6.05 Nos. m


3

Qty for 2Lane 4 580.80

17 14.11 Reinforced cement concrete

0.3

4.00

12

m3

28.80

18 14.10

19

13.8

20

8.47

21

8.4

22 15.11

23

15.9

24 15.10 25 Analysi
s rate

approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course 2 below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom shank to the top Sign board : Retroof reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 madeFlexible of high intensity Stone apron Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification. HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

0.15

4.00

12

m3 Nos.

14.40

40

80

Nos.

17.28

m2

17.28

189.54 m3

189.54

228.00 m3

228.00

1 2

83.34 23.36

m3 m

83.34 46.72

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no- 260/4,Ch-259580
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

42.58 128.52

356.00 573.00

15,159.00 73,644.00

I.Ordinary Soil B.Mechanical means


(II) With dewatering

3/12.8

(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

296.45

54.00

16,009.00

Cum Cum

8.57 53.76

6514.00 9030.00

55,851.00 485,453.00

4/12.40

Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications tonne 5.38 73279.00 393,948.00

5/13.5

Item No. 1

Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cum

18.43

9169.00

168,994.00

6/13.6

Tonne

1.84

73343.00

135,135.00

7/14.1

Cum

33.67

10591.00

356,599.00

8/14.2

tonne

2.69

77554.00

208,900.00

9/14.18

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

Item No. 1 10/8.22

Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

B. M 40 grade concrete Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 11/14.7

metre metre

46.72 23.36

4170.00 2044.00

194,823.00 47,748.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

4.00 20.00

10197.00 204.00

40,788.00 4,080.00

Each Each

4.00

3500.00 3400.00

13,600.00

Item No. 1 17/8.51

Particulars/Descrption of items 2 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.

Unit 3 Each

Total Quantity 4 15.00

Rate in Rs. 5 298.00

Amount (Rs.) 6 4,470.00

18/16.1

Sqm

115.20

78.00

8,986.00

19/16.17 Replacement of Expansion Joints complete as per Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 177 b)16 mm dia re-bar fastners 25% of 177 C)20 mm dia re-bar fastners 25% of 177 d)25 mm dia re-bar fastners 25% of 177 20/16.2

metre Sqm

25.50 130.56

3628.00 59.00

92,514.00 7,704.00

Sqm

28.63

614.00

17,577.00

Each Each Each Each

44.23 44.23 44.23 44.23

500.00 700.00 750.00 800.00

Total-

22,115.00 30,960.00 33,172.00 35,383.00 3,038,405.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br no :260/4,Ch- 259580 m


Sl. Item No. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20.
Wing wall2 (B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 0.9 Rail2 2 0.2 0.175 Kerb2 0.5 0.2 Slab2 7.4 0.65 Dirt wall2 0.25 0.65 Abut/Pier2 1.83 0.7+1.0 2

Unit

Qty for 2Lane 42.58 1.61 2.77 4.67 38.00 1.28 12.29 7.23 60.67 128.52 141.05 155.40 296.45 8.57 8.57 53.76 53.76 5376.00 5376.00 5.4 10.89 6.41 1.14 18.43 1842.50 1842.50 1.84 33.67 33.67 2693.60 2693.60 2.69 4.00

21.29 Cm 13 19.785 23.36 3.95 3.95 3.95 3.95 1 Total= 2.6 4.0 Cm Cm Cm Cm Cm Cm Cm Cm Cm 3 m 3 m

1
Raft-

1 15.36 15.5 3.5

1.83 3.95 3.5 5.55

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

12.8 PCC M15-

15.66

3.65

Total= m3 0.15 m3 Total= 1 Total= 100 kg Total= kg Total= Tonne 1.83 1.83 0.25 Total= 100 Total= Total= 0.65 Total= 80 Total= Total= 2 m3 m3 Kg Kg
Tonne

12.8 RCC M35 (open foundation)-

15.36

3.5

12.40 Reinforcement in foundation-

53.76

13.5 Substructure(M35)-

2 2

0.7+1.0 2
1.00

3.5 3.5 3.5 18.425

0.65

13.6 Reinforcement in Substructure-

8 9

14.1 Superstructure RCC (M25)14.2 Reinforcement in Superstructure-

3.5

7.4 33.67

m3 m3 Kg Kg
Tonne

10

14.9 Drainage Spouts complete as


per drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

Nos.

11

3 3 3 3

12 12 12 12

Nos. Nos. Nos. Nos.

36.00 36.00 36.00 36.00

Sl. Item No. No. 12 14.10 PCC M15 grade levelling


course below approach slab complete as per drawing and technical specification. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) Replacement of Expansion Joints complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery.

Unit
2 11.5

0.3

Qty for 2Lane 27.60

13 14.11

11.5

0.3

27.60

14

14.7

23.36

23.36

15

8.22

23.36

46.72

16

16.1

7.5

15.36

115.20

17 16.17 18 16.2

3 8.5

8.5 15.36 metre

25.50 130.56

19

13.8

10

Nos.

20.00

20

8.47

Nos.

4.00

Sl. Item No. No. 21 8.51 RPM: Providing relfective


pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

Unit 15 Nos.

Qty for 2Lane 15.00

22 16.28 Supplying and applying Epoxy


based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

2
2

0.65
0.7+1.0 2

0.25 1.83 1.83 23.36

sqm sqm sqm sqm

0.33 3.11 1.83 23.36 28.63 177

1 1

Total- sqm

23

16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

106.148 Each 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

177

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br Ch-259580
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35

Cum

970.04

54.00

52,382.00

Cum

89.73 236.82

6514.00 9030.00

584,499.00 2,138,485.00

(II) Using Batching plant Transit mixer and concrete Cum pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

22.80

73279.00

1,670,595.00

52.96

8120.00

430,036.00

86.29

9169.00

791,151.00

Item No. 1

Particulars/Descrption of items

Unit

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

18.61

73343.00

1,364,955.00

6/14.1 Furnishing and Placing Reinforced/Prestressed cement

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

Cum

107.02

10591.00

1,133,449.00

MT

7.31

77554.00

567,230.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

17.28

5200.00

89,856.00

Item No.

Particulars/Descrption of items

Unit

Total Quantity 4 198.56

Rate in Rs. 5 12993.00

Amount (Rs.) 6 2,579,891.00

1 2 3 10/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications. 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 12/Analy HAND RAIL metre sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ metre with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 15/14.10 PCC M15 grade levelling course below approach Cum, slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Each Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing RM 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum

46.72 46.72

4170.00 1475.00

194,823.00 68,912.00

23.36

2044.00

47,748.00

28.80 14.40

12025.00 5498.00

346,320.00 79,172.00

4.00

10197.00

40,788.00

70.08

160.00

11,213.00

237.79

1524.00

362,396.00

Item No.

Particulars/Descrption of items

Unit 3 Each

Total Quantity 4 30.00

Rate in Rs. 5 204.00

Amount (Rs.) 6 6,120.00

1 2 19/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

Cum Cum Cum

59.59 135.54

4333.00 7046.00 1485.00

0.00 419,872.00 201,277.00

Cum

145.14

1679.00

243,691.00

Total-

13,529,613.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No: 260/4 , Ch- 259580 m


Sl. Item no. No. 1 12.1 Earth work or foundation
of structures as per drawings & technical specification including setting out.

Unit

Qty for 2Lane 516.10 11.52 8.63 135.54 41.46 103.68 92.87 60.24 970.04 27.65 34.56 13.82 13.70 89.73

2 2 2

15.36 15.36 11.5


20.08 20.08+15.36 2

12 0.25 0.25 9 2.6 15.36 1.85 1.5

2.8 1.5 1.5 0.75 0.45

m3 m3 m3 3 m 3 m

15 20.08 20.08 2 12.8 PCC M-15 = 12 15.36 2 c/wall


20.08+15.36 2

0.45 m3 2.5 m3 2 m3 Total = 0.15 0.15 0.15 13.7 m m3 3 m m3 Total= m3


3

15.36 15 2.6 1

12.8

RCC M35(open foundation)

m/wall 4 12.40 Reinforcement in foundation = 20 mm dia 16 mm dia 12 mm dia 12 mm dia m/wall

2 2 2

12 0.25 0.25 1.2

1 1.5 1.5 3

15.36 12 14.8 4.5 Total= 32.8 26.5 54 2 32.4 Total = Total =

m m3 m3 m3

184.32 9.00 11.10 32.40 236.82 9718.52 8710.32 480.00 648.89 3240.00 22797.73 22.80

2 2

60 104 10 365 100

kg kg kg kg kg kg
Tonne

13.5

Substructure (M35) Dirt wall


Abutment cap

Abutment Pier cap Pier M/wall

2 2 2 1 1 2

0.65 0.7 0.7+1.0 2 0.225


1

12 12 1.602 1 1.602 3.077

0.25 0.225 12 12 12 12 Total=

m3 3 m m3 m3 m3 3 m

3.90 3.78 32.68 2.70 19.22 24.00 86.285 52.96 283.20 238.51

0.2+0.45 2

6 7

13.5 13.6

Substructure (M20) PCC Wing wallReinforcement in substuctureDirt wall 12 mm dia 12 mm dia

1 2 2 6 0.78 26.55 2

52.96 m3 kg kg

86

Sl. Item no. No.


Abutment cap

Unit 12 12 12 12 25 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia 2 2 1 1 2 2 2 2 2 2 10 1.85 10 1.85 2 27.3 100 100 27.3 100 m/wall 13.5 86 13.5 86 100 11 11 3.95 11 11 100 3.95 1.2 kg kg kg kg kg kg kg

Qty for 2Lane 240.00 282.84 120.00 141.42 6095.68 533.87 2346.67

Pier cap

Abutment

Pier

14.1

14.2

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification.

kg 3047.84 kg 533.87 1.2 kg 2346.67 24 2400.00 m3 Total = kg 18610.56 Total = Tonne 18.61 53.51 m3 107.02

3.657

MT

7.31

10

14.18 Filler joint Providing & fixing 20 mm


thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

12

Nos.

36.00

11

8.22

12

14.7

Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing

23.36

46.72

23.36

23.36

13

14.16 Painting on concrete surface

23.36

m2

70.08

14

14.4

15

14.9

Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification.

8.50

23.36

198.56

Nos.

Sl. Item no. No. 16 13.9 Back filling behind Abutment ,Wing
wall and Return Wall complete as per drawing and technical specification with Granular Material.

Unit 2 12 4.00 2.477 m3

Qty for 2Lane 237.79

17

14.11 Reinforced cement concrete


approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification.

0.3

4.00

12

m3

28.80

18

14.10

0.15

4.00

12

m3

14.40

19

13.8

Nos.

30

20

8.47

Nos.

21

8.4

17.28

m2

17.28

22

15.11

135.54 m3

135.54

23

15.9

145.14 m3

145.14

24

15.10

59.59

m3 m

59.59

25 Analysis HAND RAIL


rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

23.36

46.72

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no- 260/5, Ch-259685 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

44.90 129.93

356.00 573.00

15,985.00 74,450.00

I.Ordinary Soil B.Mechanical means


(II) With dewatering

(i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 4/12.40
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

Cum

208.39

54.00

11,254.00

Cum

8.57

6514.00

55,851.00

Cum

53.76

9030.00

485,453.00

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel reinforcement bar of Fe-500 N/mm2 (CRS) tonne 5.4 73279.00 393,948.00

Item No. 1 5/13.5

Particulars/Descrption of items 2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cum

19.68

9169.00

180,432.00

6/13.6

Tonne

1.97

73343.00

144,244.00

7/14.1

Cum

33.67

10591.00

356,599.00

8/14.2

tonne

2.69

77554.00

208,900.00

9/14.18

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

Item No. 1

Particulars/Descrption of items

Unit 3 metre

2 (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).

Total Quantity 4 36.00

Rate in Rs. 5 17.00

Amount (Rs.) 6 612.00

metre metre

46.72 23.36

4170.00 2044.00

194,823.00 47,748.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

4.00 24.00

10197.00 204.00

40,788.00 4,896.00

Item No. 1

Particulars/Descrption of items 2 a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

Unit 3 Each Each Each

Total Quantity 4 4.00 15.00

17/8.51

Rate in Rs. 5 3500.00 3400.00 298.00

Amount (Rs.) 6 13,600.00 4,470.00

18/16.1

Sqm

115.20

78.00

8,986.00

19/16.17 Replacement of Expansion Joints complete as per


drawings.

metre Sqm

25.50 130.56

3628.00 59.00

92,514.00 7,704.00

Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 192 b)16 mm dia re-bar fastners 25% of 192 C)20 mm dia re-bar fastners 25% of 192 d)25 mm dia re-bar fastners 25% of 192

20/16.2

Sqm

28.13

614.00

17,274.00

Each Each Each Each

47.96 47.96 47.96 47.96

500.00 700.00 750.00 800.00

Total-

23,982.00 33,574.00 35,972.00 38,370.00 3,066,604.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br no.260/5 ,Ch- 259685 m


Sl. Item No No. . 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20. Wing wall2
(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 0.275 0.25 Rail2 2 0.2 Kerb2 0.5 Slab2 0.65 Dirt wall2 0.25 Abut/Pier2 0.7+1.0 2

Unit Qty for 2Lane 22.45 13 19.785 23.36 3.95 3.95 1.962 3.95 1 Total= 1.88 4.0 Total= 0.15 Total= 1 Total= 100 Total= Total= 1.962 1.96 m3 0.25 Total= m3 100 Kg Total= Kg Total= Tonne 0.65 m3 Total= m3 80 Kg Total= Kg Total= Tonne 2 12 12 12 12 Nos. Nos. Nos. Nos. Nos. Cm Cm Cm Cm Cm Cm Cm Cm Cm Cm 3 m m3 m3 m3 44.90 1.61 2.77 4.67 38.00 1.28 13.17 7.75 60.67 129.93 101.99 106.40 208.39 8.57 8.57 53.76 53.76 5376.00 5376.00 5.4 11.67 6.87 1.14 19.68 1966.70 1966.70 1.97 33.67 33.67 2693.60 2693.60 2.69 4.00 36.00 36.00 36.00 36.00

0.9 0.175 0.2 7.4 0.65 3.95 1.962 3.95 3.5 3.8

1
Raft-

1 15.36 15.5 3.5

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

3 4 5

12.8 PCC M1512.8 RCC M35 (open foundation)12.40 Reinforcement in foundation-

15.66 15.36

3.65 3.5 53.76

kg kg
Tonne

13.5 Substructure(M35)-

2 2

0.7+1.0 2
1.00

3.5 3.5 3.5

0.65

13.6 Reinforcement in Substructure-

19.667

14.1 Superstructure RCC (M25)-

3.5

7.4

14.2 Reinforcement in Superstructure-

33.67

10 11

14.9 Drainage Spouts complete as


per drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

2 3 3 3 3

Sl. Item No No. . 14.10 PCC M15 grade levelling 12


course below approach slab complete as per drawing and technical specification 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery.

11.5

0.3

Unit Qty for 2Lane 3 27.60 m

13

11.5

0.3

27.60

14

23.36

23.36

15

23.36

46.72

16

7.5

15.36

sqm

115.20

17

8.5

metre

25.50

18

8.5

15.36

metre

130.56

19

12

Nos.

24.00

20

Nos.

4.00

Sl. Item No No. . 21 8.51 RPM: Providing relfective


pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 16.28 Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

15

Unit Qty for 2Lane Nos. 15.00

22

2
2

0.65
0.7+1.0 2

0.25 1.962 1.112 23.36

sqm sqm sqm sqm

0.33 3.34 1.11 23.36 28.13 192

1 1

Total- sqm

23

16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

115.11 Each 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

192

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no : 260/5,Ch-259685
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35

Cum

950.61

54.00

51,334.00

Cum Cum

91.29 236.82

6514.00 9030.00

594,652.00 2,138,485.00

(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications.

4/13.5

5/13.6

(A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

19.20

73279.00

1,406,954.00

55.84

8120.00

453,421.00

90.99

9169.00

834,332.00

Item No. 1

Particulars/Descrption of items

Unit

2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure
and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

18.90

73343.00

1,386,270.00

6/14.1 Furnishing

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

Cum

107.02

10591.00

1,133,449.00

MT

7.31

77554.00

567,230.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

10/14.4 Providing and laying Cement concrete wearing coat M- m3 30 grade including reinforcement complete as per drawing and Technical Specifications.

17.28 198.56

5200.00 12993.00

89,856.00 2,579,891.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

46.72 46.72

4170.00 1475.00

194,823.00 68,912.00

metre

23.36

2044.00

47,748.00

Cum Cum,

28.80 14.40

12025.00 5498.00

346,320.00 79,172.00

16/14.9 Drainage Spouts complete as per drawing and Each Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing RM 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum

4.00

10197.00

40,788.00

70.08

160.00

11,213.00

250.75

1524.00

382,147.00

Item No.

Particulars/Descrption of items

Unit

1 2 3 19/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 21/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) Cum Cum B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick Cum comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring Cum at cross drainage works for relatively less important works

Total Quantity 4 30.00

Rate in Rs. 5 204.00

Amount (Rs.) 6 6,120.00

4.00

3500.00 3400.00 298.00

13,600.00 0.00

62.33 141.75

4333.00 7046.00 1485.00

0.00 439,178.00 210,499.00

149.82

1679.00

251,548.00

Total- 13,419,094.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.260/5,Ch-259685


Sl. Item no. No. 1 12.1
Earth work or foundation of structures as per drawings & technical specification including setting out.

Unit

Qty for 2Lane

2 2 2

15.36 15.36 11.5


21 21+15.36 2

12 0.25 0.25 9 2.82 15.36 1.85 1.5

2.66 1.5 1.5 0.75 0.45

m m3 3 m m3 m3

490.29 11.52 8.63 141.75 46.14 92.16 97.13 63.00 950.61

15 21 21

0.4 m3 3 2.5 m 2 m3 Total =

12.8

PCC M-15 12 15.36 2 c/wall


21+15.36 2

15.36 15 2.82 1

0.15 0.15 0.15

m3 m3 m3

27.65 34.56 15.38 13.70 91.29

13.7 m3 Total=

12.8

RCC M35(open foundation)

m/wall

2 2 2

12 0.25 0.25 1.2

1 1.5 1.5 3

15.36 12 14.8 4.5 Total=

m3 m3 m3 m3

184.32 9.00 11.10 32.40 236.82

12.40

Reinforcement in foundation 25 mm dia 16 mm dia 12 mm dia 12 mm dia m/wall

2 2

100

47 104 10 365 32.4

16.86 26.5 54.72 2

kg 6114.35 kg 8710.32 kg 486.40 kg 648.89 kg 3240.00 Total = kg 19199.96 Total = Tonne 19.20

13.5

Substructure RCC (M35) Dirt wall


Abutment cap

Abutment Pier cap Pier M/wall

2 2 2 1 1 2

0.65 0.7 0.7+1.0 2 0.225


1

12 12 1.737 1 1.737 3.12

0.25 0.225 12 12 12 12 Total=

m m3 m3 m 3 m m3
3

3.90 3.78 35.43 2.70 20.84 24.34 90.995

0.2+0.45 2

Sl. Item no. No. 6 13.5 Substructure (M20) PCC Wing wallReinforcement in substuctureDirt wall 12 mm dia 12 mm dia
Abutment cap

Unit

Qty for 2Lane

55.84 m3

55.84

13.6

2 2 2 2 1 1 2 2 2

0.78

6 2 10 1.85

26.55 86 13.5 86

kg kg kg kg kg kg

283.20 238.51 240.00 282.84 120.00 141.42 6265.43 533.87 2346.67

12 12 12 12 25 12 12 25 12 12

mm dia mm dia mm dia mm dia mm dia mm dia mm dia

Pier cap

10 1.85 2 100

13.5 86 100 27.3 11 100 27.3 11 100 4.06 11 1.2 4.06 11 1.2 24.36 Total = Total = 53.51

Abutment

kg kg kg

Pier=

mm dia 2 mm dia 2 mm dia 2 100 M/wall=

14.1

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence on of vertical RCC post not to Painting concrete surface (Providing and applying 2 coats of water based cement paint to Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with

kg 3132.72 kg 533.87 kg 2346.67 kg 2436.00 kg 18901.19 Tonne 18.90 3 107.02 m

14.2

3.657

MT

7.31

10

14.18

12

Nos.

36.00

11

8.22

23.36

46.72

12

14.7

23.36

23.36

13

14.16

23.36

m2
3

70.08

14

14.4

8.50

23.36

198.56

15 16

14.9 13.9

2 2 12 4.00

2 2.612

Nos. m3

4 250.75

Sl. Item no. No. 17 14.11


Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification.

Unit

Qty for 2Lane 28.80

0.3

4.00

12

18

14.10

0.15

4.00

12

14.40

19

13.8

30

Nos.

30

20

8.47

Nos.

21

8.4

17.28

m2

17.28

22

15.11

141.75 m3

141.75

23

15.9

149.82 m3

149.82

24 25

15.10

1 2

62.33 23.36

m3 m

62.33 46.72

Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

Executive Engineer, PWD Nagaon NH Division, Nagaon

380.1336 490.875

60 47

22808.02 23071.13

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-260/6, Ch-259870 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

68.12 109.87

356.00 573.00

24,251.00 62,955.00

I.Ordinary Soil B.Mechanical means


(II) With dewatering

(i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 4/12.40 Reinforcement in Foundation: Supplying, fitting and
placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

Cum

215.53

54.00

11,639.00

Cum Cum

5.74 38.29

6514.00 9030.00

37,414.00 345,759.00

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications tonne 3.8 73279.00 280,586.00

5/13.5

Item No. 1

Particulars/Descrption of items

Unit 3

2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cum

19.78

9169.00

181,382.00

Tonne

1.98

73343.00

145,088.00

Cum

32.76

10591.00

346,962.00

tonne

2.62

77554.00

203,254.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

37.88 18.94

4170.00 2044.00

157,960.00 38,714.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

2.00 24.00

10197.00 204.00

20,394.00 4,896.00

Each Each

4.00

3500.00 3400.00

13,600.00

Item No.

Particulars/Descrption of items

Unit 3 Each

1 2 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per
drawings.

Total Quantity 4 12.00

Rate in Rs. 5 298.00

Amount (Rs.) 6 3,576.00

Sqm

82.05

78.00

6,400.00

metre Sqm

17.00 92.99

3628.00 59.00

61,676.00 5,487.00

20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 106 b)16 mm dia re-bar fastners 25% of 106 C)20 mm dia re-bar fastners 25% of 106 d)25 mm dia re-bar fastners 25% of 106

Sqm

15.50

614.00

9,516.00

Each Each Each Each

26.50 26.50 26.50 26.50

500.00 700.00 750.00 800.00

Total-

13,250.00 18,550.00 19,875.00 21,200.00 2,578,787.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br. No :260/6,Ch-259870 m


Sl. No. 1 Item No. 2.4 Unit
Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 Wing Wall2 (B) Prestressed/ Reinforced cement grade M-20 & above Post 2 0.275 0.25 0.9 Rail2 2 0.2 0.175 Kerb2 0.5 0.2 Slab1 10.4 0.9 Dirt wall2 0.9 0.25 Abut/Pier2 0.7+1.0 2 3.057 Raft-

Qty for 2Lane 68.12 1.36 2.23 3.79 36.97 1.78 20.53 43.21 109.87 64.33 151.20 215.53 5.74 5.74 38.29 38.29 3829.00 3829.00 3.8 18.207 1.58 19.78 1978.20 1978.20 1.98 32.76 32.76 2620.80 2620.80 2.62 2.00

34.06 11 15.915 18.94 3.95 3.95 3.95 3.95 Total= 3.5 4.0 Total= 0.15 Total= 3.5 Total= 100 Total= Total= 3.06 0.90 Total= 100 Total= Total= 0.9 Total= 80 Total= Total= 2

Cm Cm Cm Cm Cm Cm Cm Cm Cm

10.94 10.94 3.5

1 1.68 5.4

12.1

Earth work in or foundation of structures as per drawings & technical specification including setting out.(Upto 3m)PCC M15RCC M35 (open foundation)-

m m3 m3 m3

3 4 5

12.8 12.8

10.94 10.94

3.5 1 38.29

12.40 Reinforcement in foundation-

kg kg
Tonne

13.5

Substructure(M35)-

2 2

0.7+1.0 2
0.25

3.5 3.5 19.782

13.6

Reinforcement in Substructure-

m m3 Kg Kg
Tonne

8 9

14.1 14.2

Superstructure RCC (M25)Reinforcement in Superstructure-

3.5

10.4 32.76

m3 m3 Kg Kg
Tonne

10

11

12

Drainage Spouts complete as per drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification

14.9

Nos.

2 2 2 2
2 11.5

12 12 12 12 0.3

Nos. Nos. Nos. Nos. m


3

24.00 24.00 24.00 24.00 27.60

Sl. Item No. No. 13 14.11 Reinforced cement concrete


approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe,

Unit
2 11.5

0.3

m3

Qty for 2Lane 27.60

14

18.94

18.94

15

18.94

37.88

16

7.5

10.94

Sqm

82.05

17

8.5

metre

17.00

18

8.5

10.94

metre

92.99

19

12

Nos.

24.00

20

8.47

Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

Nos.

4.00

21

8.51

12

Nos.

12.00

Sl. Item No. No. 22 16.28 Supplying and applying Epoxy


based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

Unit 0.9
2

2
0.7+1.0 2

0.25 3.06 10.94

sqm sqm sqm

Qty for 2Lane 0.45 5.20 9.85

0.9

Total- sqm

23

16.53

Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

63.6 0.6

Each

15.50 106

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing Br no : 260/6, Ch-259870 m
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum

795.80

54.00

42,974.00

77.08 245.78

6514.00 9030.00

502,122.00 2,219,349.00

3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Cum Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

28.34

73279.00

2,076,731.00

84.62

8120.00

687,115.00

75.84

9169.00

695,368.00

Item No. 1

Total Rate in Quantity Rs. 2 3 4 5 (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne 14.75 73343.00 of Fe-500 N/mm2 Super Structure Particulars/Descrption of items Unit
in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Amount (Rs.) 6 1,082,080.00

6/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification.

Cum

106.40

10591.00

1,126,883.00

MT

7.05

77554.00

546,524.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

(iv)'Providing and filling joint sealing compound as per metre drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

24.00

17.00

408.00

9/14.4

Providing and laying Cement concrete wearing coat M-30 m3 grade including reinforcement complete as per drawing and Technical Specifications.

17.28 160.99

5200.00 12993.00

89,856.00 2,091,744.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I)

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

37.88 37.88

4170.00 1475.00

157,960.00 55,873.00

12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification Cum a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical Each specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. RM

18.94

2044.00

38,714.00

28.80 14.40 4.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 40,788.00

56.82

160.00

9,092.00

(A) Granular material Cum 18/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification

438.72 30.00

1524.00 204.00

668,610.00 6,120.00

Item No.

Particulars/Descrption of items

Unit

1 2 3 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 20/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
21/15.10 Curtain wall complete as per drawing and Technical

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

4.00

3500.00 3400.00 298.00

13,600.00 0.00

specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Cum Cum Cum

57.78 130.54

4333.00 7046.00 1485.00

0.00 407,118.00 193,852.00

Cum

131.06

1679.00

220,050.00

Total- 13,458,783.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.260/6 , Ch-259870 m


Sl. Item no. No . 1 12.1 Earth work or
foundation of structures as per drawings & technical specification including setting out.

Unit

Qty for 2Lane

2 2

10.94 10.94 11.5


19.34

2 19.34+10.94
2

12 0.25 0.25 9 4.2 10.94 1.85 1.5

2.88 1.5 1.5 0.75 0.45 0.4 2.5 2

m m3 3 m m3 m3 m3 3 m m3 Total =

378.09 8.21 8.63 130.55 57.23 65.64 89.45 58.02 795.80

15 19.34 19.34

12.8

PCC M-15 = 12 10.94 2 19.34+10.94


2

10.94 15 4.2 1

0.15 0.15 0.15 13.7

m3 m3 m3 m3 Total= m3

19.69 24.62 19.08 13.70 77.08

c/wall

12.8

RCC M35(open foundation)

m/wall

2 2 2

12 0.25 0.25 1.2

1.5 1.5 1.5 3

10.94 12 9.94 4.5

m3 m3 m3 m3 Total=

196.92 9.00 7.46 32.40 245.78

12.40

Reinforcement in foundation = 25 mm dia 16 mm dia 12 mm dia 12 mm dia m/wall

2 2

120 140

12.94 27.5 10 305 100

kg 11981.48 kg 12167.90 45.95 kg 408.44 2 kg 542.22 32.4 kg 3240.00 Total = kg 28340.05 Total = Tonne 28.34

13.5

Substructure RCC (M35) Dirt wall


Abutment cap

Abutment M/wall

2 2 2 2

0.9 0.7 0.7+1.0 2 0.2+0.45 2

12 12 2.832 4.557

0.25 0.225 12 3

m m3 m3 m
3

5.40 3.78 57.77 8.89 75.839

Total= 6 13.5 Substructure (M20) PCC Wing wall-

84.62 m3

84.62

Sl. Item no. No . 7 13.6 Reinforcement in substuctureDirt wall = 12 mm dia 12 mm dia


Abutment cap =

Unit

Qty for 2Lane

2 2 2 2

6 0.78 10 1.85 2 18 18

26.55 2 13.5 86 100 27.3 100 100

86

kg kg kg kg

283.20 238.51 240.00 282.84

12 12 25 12 12

mm dia mm dia

Abutment =

mm dia 2 mm dia 2 mm dia 2 M/wall=

14.1

14.2

10

14.18

11

8.22

12

14.7

13

14.16

14

14.4

15

14.9

16

13.9

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not surface to exceed 1 Painting on concrete (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification

kg 7947.53 kg 873.60 1.25 kg 4000.00 8.88 kg 888.00 Total = kg 14753.68 Total = Tonne 14.75 106.40 m3 106.40 7.047 MT 7.05

5.15

12

Nos.

24.00

18.94

37.88

18.94

18.94

18.94

m2

56.82

8.50

18.94

m3

160.99

Nos.

12

4.00

4.57

m3

438.72

17

14.11

0.3

4.00

12

m3

28.80

18

14.10

0.15

4.00

12

14.40

Sl. Item no. No . 19 13.8 Providing weep holes in brick


mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works.

Unit

Qty for 2Lane 30

30

Nos.

20

8.47

Nos.

21

8.4

17.28

m2

17.28

22

15.11

130.54 m3

130.54

23

15.9

131.06 m3

131.06

24

Curtain wall complete as per drawing and Technical specification. 25 Analysis HAND RAIL rate Providing and fixing hand rail over

15.10

57.78

m3 m

57.78

18.94

37.88

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-264/1, Ch-263570 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

68.24 99.63

356.00 573.00

24,294.00 57,091.00

I.Ordinary Soil B.Mechanical means


(II) With dewatering

3/12.8

(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

195.25

54.00

10,544.00

Cum Cum

5.22 34.79

6514.00 9030.00

33,994.00 314,154.00

4/12.40

Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications

tonne

3.5

73279.00

254,938.00

Item No. 1

Particulars/Descrption of items

Unit

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

6/13.6

7/14.1

2 3 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

20.18

9169.00

185,008.00

2.02

73343.00

147,985.00

Cum

26.98

10591.00

285,724.00

8/14.2

tonne

2.16

77554.00

167,381.00

9/14.18

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

Item No. 1 10/8.22

Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

B. M 40 grade concrete Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete per approved drawings 12/14.11 Reinforced cement as concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 11/14.7

metre metre

35.88 17.94

4170.00 2044.00

149,620.00 36,670.00

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

2.00 20.00

10197.00 204.00

20,394.00 4,080.00

Each Each

4.00

3500.00 3400.00

13,600.00

Item No. 1 17/8.51

Particulars/Descrption of items 2 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.

Unit 3 Each

Total Quantity 4 10.00

Rate in Rs. 5 298.00

Amount (Rs.) 6 2,980.00

18/16.1

Sqm

74.55

78.00

5,815.00

19/16.17 Replacement of Expansion Joints complete as per Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 99 b)16 mm dia re-bar fastners 25% of 99 C)20 mm dia re-bar fastners 25% of 99 d)25 mm dia re-bar fastners 25% of 99 20/16.2

metre Sqm

17.00 84.49

3628.00 59.00

61,676.00 4,985.00

Sqm

24.12

614.00

14,808.00

Each Each Each Each

24.85 24.85 24.85 24.85

500.00 700.00 750.00 800.00

Total-

12,425.00 17,395.00 18,638.00 19,880.00 2,408,482.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br No.264/1,Ch- 263570 m


Sl. No . 1 Item No. 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 Wing Wall2
(B) Prestressed/ Reinforced cement grade M-20 & above Post 2 0.275 0.25 0.9 Rail2 2 0.2 0.195 Kerb2 0.5 0.2 Slab1 9.4 0.82 Dirt wall2 0.82 0.25 Abut/Pier2 3.95 0.7+1.0 2 Raft-

Unit

Qty for 2Lane 68.24 1.24 2.33 3.59 30.45 1.62 21.15 39.26 99.63 64.77 130.48

34.12 Cm 10 14.915 17.94 3.95 3.95 3.15 1 Total= 1.86 4.0 Cm Cm Cm Cm Cm Cm Cm Cm m3 3 m

9.94 9.95 3.5

3.95 3.5 4.66

12.1

Earth work in or foundation of structures as per drawings & technical specification including setting out.(Upto 3m)-

3 4 5

12.8 12.8

PCC M15RCC M35 (open foundation)-

9.94 9.94

3.5 3.5 34.79

12.40 Reinforcement in foundation-

Total= 0.15 Total= 1 Total= 100 Total= Total= 3.15 0.82 Total= 100 Total= Total= 0.82 Total= 80 Total= Total= 2 12 12 12 12 0.3

m3 m3

kg kg
Tonne

13.5

Substructure(M35)-

2 2

0.7+1.0 2
0.25

3.5 3.5 20.177

195.25 5.22 5.22 34.79 34.79 3479.00 3479.00 3.48 18.74 1.44 20.18 2017.70 2017.70 2.02 26.98 26.98 2158.24 2158.24 2.16 2.00 24.00 24.00 24.00 24.00 27.60

13.6

Reinforcement in Substructure-

m3 m3 Kg Kg
Tonne

8 9

14.1 14.2

Superstructure RCC (M25)Reinforcement in Superstructure-

3.5

9.4 26.978

m3 3 m Kg Kg
Tonne

10 11

12

14.9 Drainage Spouts complete as per drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification

1 2 2 2 2
2 11.5

Nos. Nos. Nos. Nos. Nos. m3

Sl. Item No No. . 13 14.11 Reinforced cement concrete


approach slab including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete.

Unit
2 11.5

0.3

Qty for 2Lane 27.60

14

14.7

17.94 m

17.94

15

8.22

17.94 m

35.88

16

17 18

Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.

16.1

7.5

9.94

74.55

2 8.5

8.5 9.94 metre

17.00 84.49

19

13.8

Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

10

Nos.

20.00

20

8.47

Nos.

4.00

21

8.51

10

Nos.

10.00

Sl. Item No No. . 22 16.28 Supplying and applying Epoxy


based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

Unit 0.82
2

2
0.7+1.0 2

0.25 9.15 9.94

sqm sqm sqm

Qty for 2Lane 0.41 15.56 8.15

0.82

23

16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

Total- sqm 59.64 Each 0.6

24.12 99

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing Br no- 264/1,Ch-263570 m
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35

Cum

745.97

54.00

40,283.00

Cum Cum

56.69 459.36

6514.00 9030.00

369,253.00 4,148,021.00

(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications.

4/13.5

(A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Cum Cum

17.02

73279.00

1,247,001.00

84.89

8120.00

689,307.00

77.28

9169.00

708,595.00

Item No. 1 5/13.6

Particulars/Descrption of items 2 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure 6/14.1 Furnishing and Placing
Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

14.62

73343.00

1,072,026.00

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)

Cum

87.14

10591.00

922,900.00

MT

6.08

77554.00

471,219.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

Item No. 1

Particulars/Descrption of items 2
(v) 80cmm x 45 cm rectangular

Unit 3

Total Quantity 4 17.28 152.49

Rate in Rs. 5 5200.00 12993.00

Amount (Rs.) 6 89,856.00 1,981,303.00

10/14.4 Providing and laying Cement concrete wearing coat M- m3 30 grade including reinforcement complete as per drawing and Technical Specifications. 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. metre B. M 40 grade concrete metre 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with metre 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification Cum a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum Each

35.88 35.88

4170.00 1475.00

149,620.00 52,923.00

17.94

2044.00

36,670.00

28.80 14.40

12025.00 5498.00

346,320.00 79,172.00

2.00

10197.00

20,394.00

RM

53.82

160.00

8,612.00

381.12

1524.00

580,827.00

Item No.

Particulars/Descrption of items

Unit 3 Each

Total Quantity 4 40.00

Rate in Rs. 5 204.00

Amount (Rs.) 6 8,160.00

1 2 18/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 21/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

Cum Cum Cum

54.67 124.34

4333.00 7046.00 1485.00

0.00 385,205.00 184,645.00

Cum

121.20

1679.00

203,495.00

Total- 13,870,175.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.264/1 Ch-263570 m


Sl. Item no. No . Earth work or foundation of 1 12.1
structures as per drawings & technical specification including setting out.

Unit Qty for 2Lane 9.94 0.25 0.25 18.42 15 2


18.42+9.94 2

2 2

12 9.94 12 9 0.45 4.24 1.85 1.5

2.88 1.5 1.5 0.75 9.94 0.45 2.5 2

m3 3 m 3 m m3 m3 3 m m m3 Total =
3

343.53 7.46 9.00 124.34 67.10 54.11 85.19 55.26 745.97

18.42 18.42

12.8

PCC M-15 11.5 2


18.42+9.94 2

9.44 4.24 0.15

0.15 0.15 9.94

m3 m3 m3 m3 Total=

16.28 18.04 22.37 0.00 56.69

15 c/wall

12.8

RCC M35(open foundation)

m/wall

2 2 2

12 0.25 0.25 30

1 1.5 1.5 1.2

9.94 12 9.44 4.5

m3 m3 m3 m3 Total=

119.28 9.00 7.08 324.00 459.36

12.40

Reinforcement in foundation 25 mm dia 16 mm dia m/wall

2 2

100 80

12.94 15 100

kg 9984.57 kg 3792.59 32.4 kg 3240.00 Total = kg 17017.16 Total = Tonne 17.02

13.5

Substructure RCC (M35) Dirt wall


Abutment cap

Abutment M/wall

2 2 2 2

0.82 0.7 07+1.0 2 0.2+0.45 2

0.25 12 2.925 3

12 0.225 12 4.57

m m3 3 m m
3

4.92 3.78 59.67 8.91 77.28

Total= 6 13.5 Substructure (M20) PCC Wing wallReinforcement in substuctureDirt wall 12 mm dia 12 mm dia

84.89 m3

84.89

13.6

2 2

6 0.95

26.55 2

86

kg kg

283.20 290.49

Sl. Item no. No . Abutment cap

Unit Qty for 2Lane 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 M/wall 10 1.85 2 20 100 13.5 86 100 27.3 20 100 5.25 kg kg 240.00 282.84

Abutment

kg 8101.85 kg 970.67 1 kg 3555.56 8.92 kg 892.00 Total = kg 14616.61 Total = Tonne 14.62 87.14 m3 87.14

14.1

14.2

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material.

6.076

MT

6.08

10

14.18

12

Nos.

24.00

11

8.22

17.94

35.88

12

14.7

17.94

17.94

13

14.16

17.94

m2

53.82

14

14.4

8.50

17.94

152.49

15 16

14.9 13.9

1 2 12 4.00

2 3.97

Nos. m
3

2 381.12

Sl. Item no. No . 17 14.11 Reinforced cement concrete approach


slab including reinforcement and formwork complete as per drawing and Technical specification.

Unit Qty for 2Lane 2 0.3 4.00 12 m


3

28.80

18

14.10

PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall.

0.15

4.00

12

14.40

19

13.8

40

Nos.

40

20

8.47

Nos.

21

8.4

17.28

m2

17.28

22

15.11

124.34 m3

124.34

23

24 25

Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. 15.10 Curtain wall complete as per drawing and Technical specification. Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

15.9

121.20 m3

121.20

1 2

54.67 17.94

m3 m

54.67 35.88

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-264/2 , Ch-263955 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

61.72 87.77

356.00 573.00

21,973.00 50,294.00

I.Ordinary Soil B.Mechanical means


(II) With dewatering

3/12.8

(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

181.25

54.00

9,788.00

Cum Cum

5.22 32.70

6514.00 9030.00

33,994.00 295,305.00

4/12.40

Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m

tonne

3.27

73279.00

239,623.00

Item No. 1

Particulars/Descrption of items 2 Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

Unit 3 Cum

Total Rate in Quantity Rs. 4 5 11.60 9169.00

Amount (Rs.) 6 106,366.00

6/13.6

7/14.1

8/14.2

9/14.18

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in metre expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board metre in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. metre

1.16

73343.00

85,078.00

26.98

10591.00

285,724.00

2.16

77554.00

167,381.00

24.00

1640.00

39,360.00

24.00

558.00

13,392.00

24.00

317.00

7,608.00

24.00

17.00

408.00

Item No. 1 10/8.22

Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

B. M 40 grade concrete metre Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 13/14.10 PCC M15 grade levelling course below approach slab Cum complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical Each specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 17/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 11/14.7

35.88 17.94

4170.00 2044.00

149,620.00 36,670.00

27.60 27.60 2.00 20.00

12025.00 5498.00 10197.00 204.00

331,890.00 151,745.00 20,394.00 4,080.00

4.00 10.00

3500.00 3400.00 298.00

13,600.00 2,980.00

Item No. 1 18/16.1

Particulars/Descrption of items 2 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

Unit 3 Sqm

Total Quantity 4 74.55

Rate in Rs. 5 78.00

Amount (Rs.) 6 5,815.00

19/16.17 Replacement of Expansion Joints complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 90 b)16 mm dia re-bar fastners 25% of 90 C)20 mm dia re-bar fastners 25% of 90 d)25 mm dia re-bar fastners 25% of 90 20/16.2

metre Sqm

17.00 84.49

3628.00 59.00

61,676.00 4,985.00

Sqm

11.46

614.00

7,039.00

Each Each Each Each

22.45 22.45 22.45 22.45

500.00 700.00 750.00 800.00

11,226.00 15,717.00 16,839.00 17,962.00 Total- 2,208,532.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br no.264/2,Ch-263955,


Sl. Item No. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 Wing Wall2
(B) Prestressed/ Reinforced cement grade M-20 & above Post RailKerbSlabDirt wallAbut/PierRaft-

Unit

Qty for 2-Lane 61.72 1.24 2.09 3.59 30.45 1.62 11.89 36.91 87.77 64.77 116.48 181.25 5.22 5.22 32.70 32.70 3270.00 3270.00 3.27 10.17 1.44 11.60 1160.00 1160.00 1.16 26.98 26.98 2158.24 2158.24 2.16 2.00

30.86 10 14.915 17.94 3.95 3.95 1.77

Cm Cm Cm Cm Cm Cm Cm

2 2

0.275 2 2 1 2 2

0.25 0.2 0.5 0.82 0.82


0.7+1.0 2

0.9 0.175 0.2 9.4 0.25 3.95 3.95

9.94

0.94 Cm Total= Cm 1.86 4.0 m m3


3

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

9.95 3.5

3.5 4.16

Total= m3 9.94 3.5 0.15 m3 Total= 0.94 Total= 100 kg Total= kg Total= Tonne 1.771 0.82 m3 Total= m3 100 Kg Total= Kg Total= Tonne 0.82 m3 Total= m3 80 Total= Total= 2 Kg Kg
Tonne

12.8 PCC M15-

12.8 RCC M35 (open foundation)-

9.94

3.5

12.40 Reinforcement in foundation-

32.7

13.5 Substructure(M35)-

2 2

0.7+0.94 2 0.25

3.5 3.5

13.6 Reinforcement in Substructure-

11.6

14.1 Superstructure RCC (M25)-

3.5

9.4

14.2 Reinforcement in Superstructure-

26.978

10

14.9 Drainage Spouts complete as

Nos.

per drawing and Technical specification. 11 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

2 2 2 2

12 12 12 12

Nos. Nos. Nos. Nos.

24.00 24.00 24.00 24.00

Sl. Item No. No. 12 14.10 PCC M15 grade levelling


course below approach slab complete as per drawing and technical specification Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) Replacement of Expansion Joints complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery.

Unit
2 11.5

0.3

m3

Qty for 2-Lane 27.60

13 14.11

11.5

0.3

m3

27.60

14

14.7

17.94

17.94

15

8.22

17.94

35.88

16

16.1

7.5

9.94

74.55

17 16.17

8.5

17.00

18

16.2

8.5

9.94

metre

84.49

19

13.8

10

Nos.

20.00

20

8.47

Nos.

4.00

Sl. Item No. No. 21 8.51 RPM: Providing relfective


pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

Unit 10 Nos.

Qty for 2-Lane 10.00

22 16.28 Supplying and applying Epoxy


based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

0.82
2

2
0.7+0.94 2

0.25 1.77 9.94

sqm sqm sqm

0.41 2.90 8.15

0.82

Total- sqm

23

16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

53.884 Each 0.6

11.46 90

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing Br no: 264/2, Ch-263955
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

Cum

589.44

54.00

31,830.00

Cum Cum

49.21 167.76

6514.00 9030.00

320,561.00 1,514,873.00

3/12.40

tonne

14.06

73279.00

1,030,430.00

4/13.5

Cum

55.40

8120.00

449,848.00

Cum

46.09

9169.00

422,585.00

5/13.6

Item No. 1

Particulars/Descrption of items 2 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Tonne

8.57

73343.00

628,830.00

6/14.1

7/14.2

8/14.18

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

Cum

87.14

10591.00

922,900.00

MT

6.08

77554.00

471,219.00

metre

20.00

1640.00

32,800.00

metre

20.00

558.00

11,160.00

metre

20.00

317.00

6,340.00

metre

20.00

17.00

340.00

9/8.4

10/14.4

Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications.

17.28 152.49

5200.00 12993.00

89,856.00 1,981,303.00

Item No. 1 11/8.22

Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

B. M 40 grade concrete 11/Analysi HAND RAIL s Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.

metre metre

35.88 35.88

4170.00 1475.00

149,620.00 52,923.00

metre

17.94

2044.00

36,670.00

13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material

Cum Cum,

28.80 14.40

12025.00 5498.00

346,320.00 79,172.00

Each

2.00

10197.00

20,394.00

RM

53.82

160.00

8,612.00

Cum

248.64

1524.00

378,928.00

Item No. 1 18/13.8

Particulars/Descrption of items 2 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.

Unit 3 Each

Total Quantity 4 40.00

Rate in Rs. 5 204.00

Amount (Rs.) 6 8,160.00

19/8.47

20/8.51

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

Protection work Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
21/15.10

Cum Cum Cum

45.94 104.49

4333.00 7046.00 1485.00

0.00 323,694.00 155,168.00

Cum

98.78

1679.00

165,852.00

Total-

9,653,988.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.264/2, Ch-263955


Sl. No. 1 Unit 12.1
Earth work or foundation of structures as per drawings & technical specification including setting out.

Qty for 2Lane 251.68 7.46 9.00 104.49 67.10 31.69 71.60 46.44 589.44

2 2

9.94 0.25 0.25 15.48 15

15.48+9.94 2

12 9.94 12 9 0.45 2.77 1.85 1.5

2.11 1.5 1.5 0.75 9.94 0.45

m3 3 m m3 3 m m3 m3

15.48 15.48

2.5 m3 3 2 m Total = m3

12.8

PCC M-15 = 11.5 2


15.48+9.94 2

9.44 2.77 0.15

0.15 0.15

m3 3 m

16.28 10.56 22.37 49.21

15

9.94 m3 Total= m3

12.8

RCC M35(open foundation)

m/wall

2 2 2

12 0.25 0.25 3

1 1.5 1.5 1.2

9.94 12 9.44 4.5 Total=

m3 m3 m3 3 m m3

119.28 9.00 7.08 32.40 167.76

12.40

Reinforcement in foundation = 20 mm dia 16 mm dia m/wall

2 2

110 80

12.94 15 100

kg 7029.14 kg 3792.59 32.4 kg 3240.00 Total = kg 14061.73 Total = Tonne 14.06

13.5

Substructure RCC (M35) Dirt wall


Abutment cap

Abutment M/wall

2 2 2 2

0.82 0.7 0.7+1.0 2 0.2+0.45 2

0.25 12 12 3

12 0.225 1.546 3 Total=

m3 m3 m3 m
3

4.92 3.78 31.54 5.85 46.09

13.5

Substructure (M20) PCC Wing wall Reinforcement in substucture Dirt wall 12 mm dia 12 mm dia

55.4 m3

55.40

13.6

2 2

6 0.95

26.55 2

86

kg kg

283.20 290.49

Sl. No.
Abutment cap

Unit

Qty for 2Lane 241.78 282.84 4205.53 533.87 2151.11 585.00 8573.82 8.57 87.14

12 12 20 12 12

mm dia mm dia mm dia mm dia mm dia

2 2 2 2 2 M/wall=

10 1.85 110 11 110

13.6 86 3.871 27.3 11 100 2

kg kg kg kg 1 kg 5.85 kg Total = kg Total = Tonne 87.14 m3

Abutment

14.1

14.2

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material.

6.076

MT

6.08

10

14.18

10

Nos.

20.00

11

8.22

17.94

35.88

12

14.7

17.94

17.94

13

14.16

17.94

m2

53.82

14

14.4

8.50

17.94

152.49

15 16

14.9 13.9

1 2 12 4.00

2 2.59

Nos. m
3

2 248.64

Sl. No. 17

Unit 14.11
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works.

0.3

4.00

12

m3

Qty for 2Lane 28.80

18

14.10

0.15

4.00

12

m3 Nos.

14.40

19

13.8

40

40

20

8.47

Nos.

21

8.4

17.28

m2

17.28

22

15.11

104.49 m3

104.49

23

15.9

98.78

m3

98.78

24 25

Curtain wall complete as per drawing and Technical specification. Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

15.10

1 2

45.94 17.94

m3 m

45.94 35.88

Executive Engineer, PWD Nagaon NH Division, Nagaon

2 2 1.85 86 318.2

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-265/1, Ch-264876 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantit y 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

60.52 96.94

356.00 573.00

21,546.00 55,549.00

I.Ordinary Soil B.Mechanical means


(II) With dewatering

3/12.8

(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

232.42

54.00

12,551.00

Cum Cum

5.22 34.79

6514.00 9030.00

33,994.00 314,154.00

4/12.40

Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35

tonne

3.48

73279.00

254,938.00

Item No. 1

Particulars/Descrption of items

Unit

6/13.6

7/14.1

2 3 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Cum Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in metre expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board metre in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded metre joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. metre

Total Quantit y 4 17.37

Rate in Rs. 5 9169.00

Amount (Rs.) 6 159,280.00

1.74

73343.00

127,434.00

26.98

10591.00

285,724.00

8/14.2

2.16

77554.00

167,381.00

9/14.18

24.00

1640.00

39,360.00

24.00

558.00

13,392.00

24.00

317.00

7,608.00

24.00

17.00

408.00

Item No. 1 10/8.22

Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

Unit 3

Total Quantit y 4

Rate in Rs. 5

Amount (Rs.) 6

B. M 40 grade concrete Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 11/14.7 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.

metre metre

35.88 17.94

4170.00 2044.00

149,620.00 36,670.00

Cum Cum Each Each

27.60 27.60 2.00 20.00

12025.00 5498.00 10197.00 204.00

331,890.00 151,745.00 20,394.00 4,080.00

17/8.51

Each Each Each

4.00 11.00

3500.00 3400.00 298.00

13,600.00 3,278.00

Item No. 1 18/16.1

Particulars/Descrption of items 2 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)

Unit 3 Sqm

Total Quantit y 4 74.55

Rate in Rs. 5 78.00

Amount (Rs.) 6 5,815.00

19/16.17 Replacement of Expansion Joints complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 99 b)16 mm dia re-bar fastners 25% of 99 C)20 mm dia re-bar fastners 25% of 99 d)25 mm dia re-bar fastners 25% of 99 20/16.2

metre Sqm

17.00 84.49

3628.00 59.00

61,676.00 4,985.00

Sqm

13.62

614.00

8,363.00

Each Each Each Each

24.85 24.85 24.85 24.85

500.00 700.00 750.00 800.00

12,425.00 17,395.00 18,638.00 19,880.00 Total- 2,353,773.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br no : 265/1,Ch-264876 m


Sl. Item No. No. 1 2.4 Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20. Wing Wall2
(B) Prestressed/ Reinforced cement grade M-20 & above. Post 2 10 0.9 0.275 Rail2 2 14.915 0.2 Kerb2 17.94 0.5 Slab1 9.4 3.95 Dirt wall2 0.25 0.82 3.95 0.7+1.0 Abut/Pier2 2 Raft9.94 3.95

Unit

Qty for 2Lane 60.52 1.24 2.09 3.59 30.45 0.34 19.98 39.26 96.94 134.42 98.00 232.42 5.22 5.22 34.79 34.79 3479.00 3479.00 3.48 15.94 1.44 17.37 1737.50 1737.50 1.74 26.98 26.98 2158.24 2158.24 2.16 2.00

30.26 0.25 0.175 0.2 0.82 0.82 2.976

Cm Cm Cm Cm Cm Cm Cm

1 Cm Total= Cm 3.86 4.0 m 3 m


3

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

9.95 3.5

3.5 3.5

Total= m3 3 12.8 PCC M159.94 3.5 0.15 m3 Total= 1 Total= 100 kg Total= kg Total= Tonne 2.976 0.82 m3 Total= m3 100 Kg Total= Kg Total= Tonne 0.82 m3 Total= m3 80 Kg Total= Kg Total= Tonne 2 12 12 12 12 Nos. Nos. Nos. Nos. Nos.

12.8 RCC M35 (open foundation)-

9.94

3.5

12.40 Reinforcement in foundation-

34.79

13.5 Substructure(M35)-

2 2

0.7+1.0 2 0.25

3.15 3.5

13.6 Reinforcement in Substructure-

17.375

14.1 Superstructure RCC (M25)-

3.5

9.4

14.2 Reinforcement in Superstructure-

26.978

10 11

14.9 Drainage Spouts complete as


per drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

1 2 2 2 2

24.00 24.00 24.00 24.00

Sl. Item No. No. 12 14.10 PCC M15 grade levelling


course below approach slab complete as per drawing and technical specification 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe,

Unit
2 11.5

0.3

m3

Qty for 2Lane 27.60

13

11.5

0.3

m3

27.60

14

17.94

17.94

15

17.94

35.88

16

7.5

9.94

74.55

17 18

2 8.5

8.5 9.94 metre

17.00

84.49

19

10

Nos.

20.00

20

8.47 Providing 'Sparkle Solar Road


Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

Nos.

4.00

21

8.51

11

Nos.

11.00

Sl. Item No. No. 22 16.28 Supplying and applying Epoxy


based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

Unit 0.82
2

2
0.7+1.0 2

0.25 2.976 9.94

sqm sqm sqm

Qty for 2Lane 0.41 5.06 8.15

0.82

23

16.53 Providing, placing and fixing in


position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

Total- sqm 59.64 0.6 Each

13.62 99

Executive Engineer, PWD Nagaon NH Division, Nagaon

2400 0.3479

100 2748.41

24

280

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no-265/1 , Ch-264876
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

589.78

54.00

31,849.00

Cum Cum

55.54 160.26

6514.00 9030.00

361,780.00 1,447,148.00

3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel Cum

17.02

73279.00

1,247,001.00

84.89

8120.00

689,307.00

73.38

9169.00

672,830.00

5/13.6

Item No. 1

Particulars/Descrption of items

Unit

2 3 (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

Total Rate in Amount (Rs.) Quantity Rs. 4 5 6 12.77 73343.00 936,508.00

6/14.1

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

Cum

87.14

10591.00

922,900.00

MT

6.08

77554.00

471,219.00

metre

24.00

1640.00

39,360.00

metre

24.00

558.00

13,392.00

metre

24.00

317.00

7,608.00

metre

24.00

17.00

408.00

10/14.4 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.

17.28 152.49

5200.00 12993.00

89,856.00 1,981,303.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I)

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

metre metre

35.88 35.88

4170.00 1475.00

149,620.00 52,923.00

12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification Cum a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical Each specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 18/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Cum Each RM

17.94

2044.00

36,670.00

28.80 14.40 2.00

12025.00 5498.00 10197.00

346,320.00 79,172.00 20,394.00

53.82

160.00

8,612.00

364.42 40.00

1524.00 204.00

555,370.00 8,160.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
21/15.10 Curtain wall complete as per drawing and Technical

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Cum Cum Cum

53.42 121.50

4333.00 7046.00 1485.00

0.00 376,426.00 180,428.00

Cum

117.76

1679.00

197,720.00

Total- 10,937,884.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No.265/1,Ch-264876


Sl. No . 1 Item no. 12.1
Earth work or foundation of structures as per drawings & technical specification including setting out.

Unit

Qty for 2Lane 196.81 7.46 9.00 121.50 67.10 50.67 83.25 54.00 589.78

2 2

9.94 0.25 0.25 18 15

18+9.94 2

12 9.94 12 9 0.45 4.03 1.85 1.5

1.65 1.5 1.5 0.75 9.94 0.45

m3 3 m m3 m3 3 m m3

18 18

2.5 m3 3 2 m Total =

12.8

PCC M-15 = 11.5 2


18+9.94 2

9.44 4.03 0.15

0.15 0.15 9.94

m m3 m3 Total=

16.28 16.89 22.37 55.54

15

12.8

RCC M35(open foundation)

m/wall

2 2 2

12 0.25 0.25 3

1 1.5 1.5 1.2

9.94 2 9.44 4.5

m3 m3 m3 m3 Total=

119.28 1.50 7.08 32.40 160.26

12.40 Reinforcement in foundation 25 mm dia 16 mm dia m/wall

2 2

100 80

12.94 15 100

kg kg 32.4 kg Total = kg Total = Tonne

9984.57 3792.59 3240.00 17017.16 17.02

13.5

Substructure RCC (M35) Dirt wall


Abutment cap

Abutment M/wall

2 2 2 2

0.82 0.7 0.7+1.0 2 0.2+0.45 2

0.25 12 2.751 3

12 0.225 12 4.39

m3 m3 m3 m3

4.92 3.78 56.12 8.56 73.38

Total= m3 6 13.5 Substructure (M20) PCC Wing wallReinforcement in substuctureDirt wall 12 mm dia 12 mm dia

84.89 m3

84.89

13.6

2 2

6 0.95

26.55 2

86

kg kg

283.20 290.49

Sl. No .

Item no.
Abutment cap

Unit 12 12 25 12 12 mm dia mm dia 2 2 10 1.85 13.5 86 100 27.3 20 100 4.076 1 8.56 kg kg

Qty for 2Lane 240.00 282.84

Abutment

mm dia 2 2 mm dia 2 20 mm dia 2 100 M/wall=

14.1

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification.

87.14

kg 6290.12 kg 970.67 kg 3555.56 kg 856.00 Total = 12768.88 Total = 12.77 3 87.14 m

14.2

6.076

MT

6.08

10

14.18 Filler joint Providing & fixing 20 mm


thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete.

12

Nos.

24.00

11

8.22

17.94

35.88

12

13

14

Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing 14.4 Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.

14.7

17.94

17.94

17.94

53.82

8.50

17.94

m3

152.49

15 16

14.9 13.9

Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material.

1 2 12 4.00

2 3.796

Nos. m3

2 364.416

Sl. No . 17

Item no. 14.11 Reinforced cement concrete approach


slab including reinforcement and formwork complete as per drawing and Technical specification.

Unit 2 0.3 4.00 12 m3

Qty for 2Lane 28.80

18

14.10 PCC M15 grade levelling course below 2


approach slab complete as per drawing and technical specification

0.15

4.00

12

m3

14.40

19

13.8

20

8.47

Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3

40

Nos.

40

Nos.

21

8.4

17.28

m2

17.28

22

15.11 Stone apron Flexible Apron

121.5

m3

121.50

:Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23 15.9 Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. 24 15.10 Curtain wall complete as per drawing and Technical specification. 25 Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

117.76 m3

117.76

1 2

53.424 m3 17.94 m

53.42 35.88

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-266/1 ,Ch-265310 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Unit 3

Total Quantit y 4

Rate in Rs. 5

Amount (Rs.) 6

Cm Cm

61.32 101.20

356.00 573.00

21,830.00 57,990.00

2/12.1

I.Ordinary Soil B.Mechanical means


(II) With dewatering

3/12.8

(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump

Cum

212.73

54.00

11,488.00

Cum Cum

8.57 53.76

6514.00 9030.00

55,851.00 485,453.00

4/12.40

Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications

5/13.5

(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications

5.38

73279.00

393,948.00

Item No. 1

Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.

Unit 3

Total Quantit y 4

Rate in Rs. 5

Amount (Rs.) 6

Cum

30.44

9169.00

279,123.00

6/13.6

Tonne

3.04

73343.00

223,183.00

7/14.1

Cum

33.67

10591.00

356,599.00

8/14.2

tonne

2.69

77554.00

208,900.00

9/14.18

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

Item No. 1 10/8.22

Particulars/Descrption of items

Unit

11/14.7

2 3 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre Construction of RCC railing of M30 Grade in-situ with metre 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.

Total Quantit y 4

Rate in Rs. 5

Amount (Rs.) 6

46.72 23.36

4170.00 2044.00

194,823.00 47,748.00

12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud

Cum Cum

27.60 27.60

12025.00 5498.00

331,890.00 151,745.00

Each Each

4.00 24.00

10197.00 204.00

40,788.00 4,896.00

Each Each

4.00

3500.00 3400.00

13,600.00

Item No. 1 17/8.51

Particulars/Descrption of items 2 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.

Unit 3 Each

Total Quantit y 4 15.00

Rate in Rs. 5 298.00

Amount (Rs.) 6 4,470.00

18/16.1

Sqm

115.20

78.00

8,986.00

19/16.17 Replacement of Expansion Joints complete as per metre Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 187 b)16 mm dia re-bar fastners 25% of 187 C)20 mm dia re-bar fastners 25% of 187 d)25 mm dia re-bar fastners 25% of 187 20/16.2 Sqm

25.50 130.56

3628.00 59.00

92,514.00 7,704.00

Sqm

32.06

614.00

19,684.00

Each Each Each Each

46.84 46.84 46.84 46.84

500.00 700.00 750.00 800.00

Total-

23,419.00 32,786.00 35,128.00 37,470.00 3,233,168.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Repairing Quantity Calculation for Br no : 266/1,Ch-265310 m


Sl. Item No. No. 1 2.4
Dismantling (M20):(ii) (A) Cement concrete grade M-15 & M-20 Wing Wall2 (B) Prestressed/ Reinforced cement grade M-20 & above Post 2 0.275 0.25 0.9 Rail2 2 0.2 0.175 Kerb2 0.5 0.2 Slab1 9.4 0.82 Dirt wall2 0.82 0.25 0.7+1.0 Abut/Pier2 3.95 2 Raft9.94 3.95

Unit

Qty for 2Lane

30.66 13 19.785 23.36 3.95 3.95 3.101

Cm Cm Cm Cm Cm Cm Cm

61.32 1.61 2.77 4.67 30.45 1.62 20.82 39.26 101.20 106.33 106.40 212.73 8.57 8.57 53.76 53.76 5376.00 5376.00 5.4 18.45 10.85 1.14 30.44 3043.00 3043.00 3.04 33.67 33.67 2693.60 2693.60 2.69 4.00 36.00 36.00 36.00 36.00 27.60

12.1 Earth work in or foundation of


structures as per drawings & technical specification including setting out.(Upto 3m)-

15.5 3.5

3.5 3.8

1 Cm Total= Cm 1.96 m3 4.0 m3 Total= 0.15 Total= 1 Total= 100 Total= Total= 3.101 3.101 0.250 Total= 100 Total= Total= 0.65 Total= 80 Total= Total= 2 12 12 12 12 0.3 m3 m3 Kg Kg
Tonne

3 4 5

12.8 PCC M1512.8 RCC M35 (open foundation)12.40 Reinforcement in foundation-

15.66 15.36

3.65 3.5 53.76

m3 m3

kg kg
Tonne

13.5

Substructure(M35)-

2 2

0.7+1.0 2 1.00 0.65

3.5 3.5 3.5 30.43

13.6 Reinforcement in Substructure-

8 9

14.1

Superstructure RCC (M25)-

3.5

7.4 33.67

14.2 Reinforcement in Superstructure-

m3 m3 Kg Kg
Tonne

10 11

14.9 Drainage Spouts complete as


per drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification

2 3 3 3 3
2 11.5

Nos. Nos. Nos. Nos. Nos. m3

12

Sl. Item No. No. 13 14.11 Reinforced cement concrete


approach slab including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 2 11.5

Unit

Qty for 2Lane 27.60

0.3

14

14.7

23.36

23.36

15

8.22 Reinforced Cement Concrete


Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.

23.36

46.72

16

7.5

15.36

115.20

17 18

3 8.5

8.5 15.36 metre

25.50 130.56

19

13.8 Providing weep holes in brick


mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe,

12

Nos.

24.00

20

8.47 Providing 'Sparkle Solar Road


Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery.

Nos.

4.00

Sl. Item No. No. 21 8.51 RPM: Providing relfective


pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.

Unit

Qty for 2Lane 15.00

15

Nos.

22

16.28 Supplying and applying Epoxy


based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.

2
2

0.65
0.7+1.0 2

0.25 3.101 3.101 23.36

sqm sqm sqm sqm

0.33 5.27 3.10 23.36 32.06 187

1 1

23

16.53 Providing, placing and fixing in


position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.

Total- sqm 112.408 Each 0.6

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing Br no-266/1, Ch-265310
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

Particulars/Descrption of items 2

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2/12.8

I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork.

Cum

1017.62

54.00

54,952.00

(p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications

Cum Cum

98.86 528.42

6514.00 9030.00

643,976.00 4,771,633.00

tonne

28.27

73279.00

2,071,656.00

4/13.5

Cum

80.22

8120.00

651,387.00

Cum

137.50

9169.00

1,260,740.00

5/13.6

Item No. 1

Particulars/Descrption of items 2 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel reinforcement bar of Fe-500 N/mm2 Super Structure (CRS)

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Tonne

17.96

73343.00

1,317,314.00

6/14.1

Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.

7/14.2

(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

Cum

107.02

10591.00

1,133,449.00

(i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

MT

7.31

77554.00

567,230.00

metre

36.00

1640.00

59,040.00

metre

36.00

558.00

20,088.00

metre

36.00

317.00

11,412.00

metre

36.00

17.00

612.00

17.28

5200.00

89,856.00

Item No. 1 9/14.4

Particulars/Descrption of items

Unit

2 3 Providing and laying Cement concrete wearing m3 coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.

Total Rate in Quantity Rs. 4 5 198.56 12993.00

Amount (Rs.) 6 2,579,891.00

10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing metre 46.72 4170.00 194,823.00

metre

46.72

1475.00

68,912.00

metre

23.36

2044.00

47,748.00

Cum Cum,

28.80 14.40

12025.00 5498.00

346,320.00 79,172.00

Each

4.00

10197.00

40,788.00

RM

70.08

160.00

11,213.00

Item No.

Particulars/Descrption of items

Unit 3

1 2 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 18/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
21/15.10 Curtain wall complete as per drawing and Technical

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

Cum Each

360.10 30.00

1524.00 204.00

548,787.00 6,120.00

Each Each Each

4.00

3500.00 3400.00 298.00

13,600.00 0.00

specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works

Cum Cum Cum

69.09 157.14

4333.00 7046.00 1485.00

0.00 486,809.00 233,353.00

Cum

172.53

1679.00

289,678.00

Total-

17,600,559.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

Quantity Calculation fo Br No 266/1 Ch-265310


Sl. No. 1 Item no. 12.1 Earth work or foundation of
structures as per drawings & technical specification including setting out.

Unit

Qty for 2Lane 490.29 11.52 8.63 157.14 68.86 103.68 107.67 69.84 1017.62

2 2 2

15.36 15.36 11.5 23.28


23.28+15.36 2 15

12 0.25 0.25 9 3.96 15.36 1.85 1.5

2.66 1.5 1.5 0.75 0.45 0.45 2.5 2 Total =

m3 m3 m3 3 m 3 m m 3 m m3 m3
3

23.28 23.28

12.8

PCC M-15 12
15.36

2 c/wall

23.28+15.36 2

15.36 15 3.96 1

0.15 0.15 0.15

m m3 m3

27.65 34.56 22.95 13.70 98.86

13.7 m3 Total= m3

12.8

RCC M35(open foundation)

m/wall 4 12.40 Reinforcement in foundation = 25 mm dia 16 mm dia 12 mm dia 12 mm dia m/wall

2 2 2

12 0.25 0.25 12

1 1.5 1.5 3

15.36 12 14.8 4.5 Total=

m3 m3 m3 m3 m3

184.32 9.00 11.10 324.00 528.42

2 2

60 104 10 365

32.8 26.5 54.72 2 100

kg 15185.19 kg 8710.32 kg 486.40 kg 648.89 32.4 kg 3240.00 Total = kg 28270.80 Total = Tonne 28.27 0.25 0.225 12 1 1 4.351 m3 3 m 3 m m m3 3 m Total=
3

13.5

Substructure RCC (M35) Dirt wall


Abutment cap

Abutment Pier cap Pier M/wall

2 2 2 1 1 2

0.65 0.7 0.7+1.0 2 0.225 12 0.2+0.45 2

12 12 2.876 12 2.876 12

3.90 3.78 58.67 2.70 34.51 33.94 137.50 80.22 283.20 238.51 240.00

6 7

13.5 13.6

Substructure (M20) PCC Wing wallReinforcement in substuctureDirt wall 12 mm dia 12 mm dia


Abutment cap

1 2 2 2 6 0.78 10 26.55 2 13.5

80.22 m3 kg kg kg

86

12

mm dia

Sl. No.

Item no. 12 Pier cap 12 12 25 12 12 mm dia mm dia mm dia mm dia 2 mm dia 2 mm dia 2 M/wall= 2 1.85 1 1 2 27.3 20 86 10 1.85 100 20 100 100 13.50 86.00 5.2

Unit kg kg kg

Qty for 2Lane 282.84 120.00 141.42 8024.69 970.67 4266.67 3393.00 17961.00 17.96 107.02

Abutment

14.1

Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. compressible fibre board in expansion joint complete as per drawing & Technical Specification.

kg kg 1.2 kg 33.93 kg Total = kg Total = Tonne 53.51 m3

14.2

3.657

MT

7.31

10

14.18 Filler joint Providing & fixing 20 mm thick

12

Nos.

36.00

11

12

13

Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing

8.22

23.36

46.72

23.36

23.36

23.36

m2

70.08

14

14.4

Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material.

8.50

23.36

m3

198.56

15 16

14.9 13.9

2 2 12 4.00

2 3.751

Nos. m3

4 360.096

17

14.11 Reinforced cement concrete approach


slab including reinforcement and formwork complete as per drawing and Technical specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification

0.3

4.00

12

28.80

18

0.15

4.00

12

m3

14.40

Sl. No. 19

Item no. 13.8 Providing weep holes in brick


mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification. HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.

Unit 1 30 Nos.

Qty for 2Lane 30

20

8.47

Nos.

21

8.4

17.28

17.28

22

15.11

157.14 m3

157.14

23

15.9

172.53 m3

172.53

24

15.10

1 2

69.09 23.36

m3 m

69.09 46.72

25 Analysi
s rate

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing br no- 226/1 Ch-225454
Item No. 1
1/12.9

Particulars/Descrption of items 2 Foundation

Unit 3

Total Rate in Rs. Quantity 4 5

Amount (Rs.) 6

Providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. Well. (A) 'Assuming depth of water 1.0 m and height of island to Each be 1.25m. (c)'Providing and constructing one span service road to reach island location from one pier location to another pier metre location 2/12.10 Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per Tonne drawing and technical specification. 3/12.11 Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. (A) 'Well curb

4.00 108.00

57977.00 2472.00

231,908.00 266,976.00

54.43

101302.00

5,514,071.00

(iv)'RCC M35 Grade


Case II : With Batching Plant, Transit Mixer and Concrete Cum Pump (B) 'Well steining (viii) 'RCC M35 Grade Case II : With Batching Plant, Transit Mixer and Concrete Cum Pump (C)'Bottom Plug (iii) 'PCC Grade M30 Case II : With Batching Plant, Transit Mixer and Concrete Cum Pump (D) 'Intermediate plug (iii) 'Grade M30 PCC Case II : With Batching Plant, Transit Mixer and Concrete Cum Pump (F) 'Well cap (iv) 'RCC Grade M35 Case II : With Batching Plant, Transit Mixer and Concrete Cum Pump 4/12.18 Sinking of 12 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical metre specifications. Depth of sinking is rekonewed from bed level. A. Sandy soil (i) Depth below bed level upto 3.0 M (ii) 'Beyond 3m upto 10m depth (iii) 'Beyond 10m upto 20m (iv) 'Beyond 20m upto 30 m (a) For sinking 5/12.21 Sand filling in wells complete as per drawing and technical specifications

907.20

10003.00

9,074,722.00

11875.22

9169.00 108,883,895.00

1631.84

8924.00

14,562,541.00

105.56

8133.00

858,520.00

1233.84

9030.00

11,141,576.00

metre metre metre metre


cum

21.00 49.00 70.00 70.00 9289.06

46710.00 51791.00 68400.00 128301.00 1798.00

980,910.00 2,537,759.00 4,788,000.00 8,981,070.00 16,701,732.00

Item No. 1

Particulars/Descrption of items 2

Unit 3

Total Rate in Rs. Quantity 4 5

Amount (Rs.) 6

6/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Subsructure 7/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999 (H) 'RCC Grade M35 Case-II : 'With Batching Plant, Transit Mixer and Concrete Cum Pump 8/13.6 Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 9/13.12 Supplying, fitting and fixing in position true to line and level forged steel roller bearing conforming to IRC: 83(Pt.tonne 1) section IX and clause 2003 of MoRTH specifications capacity complete including all accessories as per drawing and Technical Specifications. 10/13.11 Supplying, fitting and fixing in position true to line and level cast steel rocker bearing conforming to IRC: 83(Pt.tonne 1) section IX and clause 2003 of MoRTH specifications capacity complete including all accessories as per drawing and Technical Specifications. Superstructure 11/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-91031999. (E) 'PSC Grade M-40 Case II : 'Using Batching Plant, Transit Mixer and Concrete Pump (ii) 'For T-beam & slab (a) Height upto 5m Cum 12/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2

816.90

73279.00

59,861,527.00

507.68

9169.00

4,654,955.00

139.85

73343.00

10,256,799.00

4200.00

1191.00

5,002,200.00

4200.00

953.00

4,002,600.00

2748.00

10920.00

30,008,160.00

351.78

77554.00

27,281,947.00

Item No. 1

Particulars/Descrption of items 2

Unit 3

Total Rate in Rs. Quantity 4 5 117.72 167708.00

Amount (Rs.) 6 19,742,586.00

13/14.3 High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete Tonne as per drawing and Technical Specifications 14/14.5 Mastic Asphalt (A) Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.

sqm

2215.44

329.00

728,880.00

15/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to metre exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 16/14.22 Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the metre manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation). 17/8.22 Reinforced Cement Concrete Crash

521.28

2044.00

1,065,497.00

84.00

11804.00

991,536.00

Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre
18/13.9 Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification (A) 'Granular material 19/13.8 Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification. 20/14.9 Drainage Spouts complete as per drawing and Technical specification 21/14.10 leveling course below approach slab complete as per drawing and Technical specification' (PCC M15 Grade)

521.28

4170.00

2,173,738.00

Cum

954.72

1524.00

1,454,994.00

Each

40.00

204.00

8,160.00

Each Cum

24.00 28.80

10197.00 5498.00

244,728.00 158,343.00

Item No. 1

Particulars/Descrption of items 2

Unit 3

Total Rate in Rs. Quantity 4 5

Amount (Rs.) 6

22/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification (A) With TATA make TMT CRS (Fe-500) grade rebar 23/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) (B) For RCC Railing 24/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Studb) Uni-directional Stud25/8.51 Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&Hs fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.

Cum

28.80

12025.00

346,320.00

RM

781.92

160.00

125,108.00

Each Each

4.00

3500.00 3400.00

13,600.00

Each

100.00

298.00

29,800.00

Protection work 26/15.5 Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications. Cum 27/15.4 Providing and laying pitching on slop laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . a) Stone/Boulder 28/15.1 Providing nad laying boulder apron on river bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical specifications. Cum 3294.180 1463.00 4819386.00 988.25 1862.00 1840122.00

Cum

2838.29 1463.00 Total cost (in Rs.) :

4152419.00 363,487,085.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

816.90 73279.00 59,861,616.00

Quantity Calculation fo Br. No. 226/1 ch-225454 m,L- 6x40m


Sl. No. Unit Qty for 2Lane

1 (i) Temporary Island 24m dia (ii) Service Road 2 Cutting edge 3 PCC/RCC work in well foundation : a) Well curb (RCC M-35) b) Well Steining (RCC M-35) 27x/4(12- 8)x7 c) Bottom Plug (PCC M-30) d) Intermediate Plug (PCC M-30) e) Well Cap (RCC M-35)

1 18 60

4 129.60

Nos. m T
3

4.00 108.00 54432.00 54.43 907.20 11875.22 1631.84

129.60

233.12

m3 3 m

7 2 5

15.08 192.82 169.64 Total-

m m3 m3

105.56 385.64 848.20 1233.84 21.00 49.00 70.00 70.00

4 Sinking of well 0 to 3 m 3 to 10 m 10 to 20 m 20 to 30 m 5 Sand fill 7 x /4 x 8 x 26.4 6 Reinforcement in foundation (HYSD bars): Well Curb mm dia 7 8.5 12 mm dia 12 7 1.8 mm dia 20 7 28.5 Steining 32 32 12 12 32 Abutment well cap 32 32 20 20 Pier 32 28 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia 5 5 7 7 2 2 2 2 2 5 5 230 200 135 135 170+150 120 120 120 120 120 120 32.5 32.5 32.5 2.5 32.5 8.5 9.1 9.1 8.5 8 8

7 7 7 7

3 7 10 10

m m m m

9289.06

188

188 41

0.89 Kg 6 0.89 Kg 2.47 Kg

9943.11 12633.60 20196.30

2 1

6.32 6.32 0.89 0.89 6.32 6.32 6.32 2.47 2.47

Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Tonne

236246.91 205432.10 54600.00 2100.00 131476.54 12894.81 13805.04 5392.59 5037.04 60681.48 46459.26 816898.79 816.90

2 2

6.32 4.84 TotalTotal-

7 Sub structure (RCC M-35)

Dirt wall Abutment Cap Return wall Abutment Pier cap Pier 8 Reinforcement in substructureDirt wall Return wall Abutment Cap Abutment 2 Pier Cap 5 Pier 5

2 2 4 2 5 5

0.3 0.23 0.6 1+1.5 2 27 2.79

12 1 3.27 3.57

3.86 12 4 12

m3 3 m 0.3 m3 3 m m 3 m Total- m3 kg kg kg kg kg kg Total- kg Total- Tonne Tonne Tonne m3 m3


3

27.79 5.52 31.39 107.10 135.00 200.88 507.684 4014.00 2480.00 1200.00 24758.00 45500.00 61895.00 139847.00 139.85 4200.00 4200.00 2748.00 2748.00 351.78 351.78 117.72

1.2

12

2 4 2

2007 620 600 12379 9100 12379

9 Roller bearing10 Rocker Bearing11 Super struture (PSC M-40)

4 4

175 175 6

6.00 6.00 458

12 Reinforcement bar in super structure (TMT CRS) 6 13 Reinforcement bar in super structure (High tensile steel) 6 14 Wearing coat(Mastic Asphalt)1 15 16 17 18 19 20 21 22 23 24 25 RCC RailingStrip seal Expansion JointCrash barrier Back fill behind abutment Leveling course (M-15) (Below approach slab)Weep holes Drainage spout Apprpoach slab (M25) Painting Soler stud RPM 8.5 260.64 1 7 2 7.65 521.28 12 260.64 12 Sqm Rm M 5.2 m3 28.8 m3 Nos. Sqm 12 m3 Sqm Nos. Nos. 2215.44 521.28 84.00 521.28 954.72 28.80 34.08 40.00 24.00 28.80 781.92 4.00 100.00 19.62 T 58.63 T T

2 6 2 3

20 4 4 260.64 1

0.3 4.00 100

Executive Engineer, PWD Nagaon NH Division,

Protection work at Bridge at chainage-225454m


Item 1 1 Descriptions 2 Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications. Unit 3 Estmated Quantity 4 Rate in Rs. 5 Amount in Rs 6

Cum 2 Providing and laying pitching on slop laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . a) Stone/Boulder

988.25

1263.00

1248159.75

Cum 3 Providing nad laying boulder apron on river bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical specifications.

3294.180

1154.00

3801483.72

Cum

2838.29 1154.00 Total cost (in Rs.) :

3275386.66 8325030.13

Executive Engineer, PWD Nagaon NH Division,

2.99 6.32

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing br no- 232/1 Ch-231240
Item No. Particulars/Descrption of items 2 Foundation
1/12.9 Providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. Well.

Unit 3

Total Rate in Rs. Quantity 4 5

Amount (Rs.) 6

(A) 'Assuming depth of water 1.0 m and height of island to Each be 1.25m. (c)'Providing and constructing one span service road to reach island location from one pier location to another pier metre location 2/12.10 Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing Tonne and technical specification. 3/12.11 Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-91031999. (A) 'Well curb

57977.00 2472.00

0.00 0.00

15.55

101302.00

1,575,449.00

(iv)'RCC M35 Grade


Case II : With Batching Plant, Transit Mixer and Concrete Pump (B) 'Well steining (viii) 'RCC M35 Grade Case II : With Batching Plant, Transit Mixer and Concrete Pump (C)'Bottom Plug (iii) 'PCC Grade M30 Case II : With Batching Plant, Transit Mixer and Concrete Pump (D) 'Intermediate plug (iii) 'Grade M30 PCC Case II : With Batching Plant, Transit Mixer and Concrete Pump (F) 'Well cap (iv) 'RCC Grade M35 Case II : With Batching Plant, Transit Mixer and Concrete Pump 4/12.18 Sinking of 12 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is rekonewed from bed level. A. Sandy soil (i) Depth below bed level upto 3.0 M (ii) 'Beyond 3m upto 10m depth (iii) 'Beyond 10m upto 20m (iv) 'Beyond 20m upto 30 m (a) For sinking 5/12.21 Sand filling in wells complete as per drawing and technical specifications

Cum

259.20

10003.00

2,592,778.00

Cum

3392.92

9169.00

31,109,685.00

Cum

466.24

8924.00

4,160,726.00

Cum

30.16

8133.00

245,292.00

Cum

385.64

9030.00

3,482,330.00

metre

metre metre metre metre


cum

6.00 14.00 20.00 20.00 2654.02

46710.00 51791.00 68400.00 128301.00 1798.00

280,260.00 725,074.00 1,368,000.00 2,566,020.00 4,771,924.00

Item No.
6/12.40

Particulars/Descrption of items 2
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Subsructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999

Unit 3

Total Rate in Rs. Quantity 4 5

Amount (Rs.) 6

tonne

165.72

73279.00

12,143,870.00

7/13.5

(H) 'RCC Grade M35 Case-II : 'With Batching Plant, Transit Mixer and Concrete Cum Pump 8/13.6 Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 9/13.12 Supplying, fitting and fixing in position true to line and level forged steel roller bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications tonne complete including all accessories as per drawing and capacity Technical Specifications.
10/13.11 Supplying, fitting and fixing in position true to line and level

145.01

9169.00

1,329,557.00

31.61

73343.00

2,318,619.00

776.00

1191.00

924,216.00

cast steel rocker bearing conforming to IRC: 83(Pt.-1) tonne section IX and clause 2003 of MoRTH specifications capacity complete including all accessories as per drawing and Technical Specifications.

776.00

953.00

739,528.00

Superstructure
11/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. (E) 'PSC Grade M-40 Case II : 'Using Batching Plant, Transit Mixer and Concrete Pump (ii) 'For T-beam & slab (a) Height upto 5m Cum 12/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 13/14.3 High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete Tonne as per drawing and Technical Specifications 14/14.5 Mastic Asphalt

510.00

10920.00

5,569,200.00

64.30

77554.00

4,986,723.00

20.70

167708.00

3,471,556.00

Item No.

Particulars/Descrption of items 2
(A) Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.

Unit 3

Total Rate in Rs. Quantity 4 5

Amount (Rs.) 6

sqm

474.64

329.00

156,157.00

15/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to metre exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 16/14.22 Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the metre manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation). 17/8.4 Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)

55.48

2044.00

113,402.00

24.00

11804.00

283,296.00

(v) 80cmm x 45 cm rectangular 18/8.22 Reinforced Cement

Sqm Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre

8.64

5200.00

44,928.00

110.96

4170.00

462,704.00

Item No.

Particulars/Descrption of items 2

Unit 3

Total Rate in Rs. Quantity 4 5

Amount (Rs.) 6

19/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier

consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I)
20/13.9 Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification (A) 'Granular material 21/13.8 Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification. 22/14.9 Drainage Spouts complete as per drawing and Technical specification 23/14.10 leveling course below approach slab complete as per drawing and Technical specification' (PCC M15 Grade) 24/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification (A) With TATA make TMT CRS (Fe-500) grade rebar 25/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) (B) For RCC Railing 26/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Studb) Uni-directional Stud27/8.51 Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&Hs fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.

metre

111.68

1475.00

164,728.00

Cum

944.05

1524.00

1,438,736.00

Each

40.00

204.00

8,160.00

Each Cum

4.00 28.80

10197.00 5498.00

40,788.00 158,343.00

Cum

28.80

12025.00

346,320.00

RM

167.52

160.00

26,804.00

Each Each

4.00

3500.00 3400.00

13,600.00

Each

60.00

298.00

17,880.00

Protection work 28/15.5 Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications.

Item No.

Particulars/Descrption of items 2

Unit 3

Total Rate in Rs. Quantity 4 5

Amount (Rs.) 6

Cum 29/15.4 Providing and laying pitching on slop laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . a) Stone/Boulder

2134.720

1862.00

3974848.64

Cum 30/15.1 Providing nad laying boulder apron on river bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical specifications.

1642.930

1463.00

2403606.59

Cum

4040.790 1463.00 Total cost (in Rs.) :

5911675.77 99,926,784.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

B. M 40 grade concrete

Executive Engineer, PWD Nagaon NH Division,

Quantity Calculation fo Br. No.232/1 Ch-231240,L-1x45m


Sl. No. 1 (i) Temporary Island 24m dia (ii) Service Road 2 Cutting edge 3 PCC/RCC work in well foundation : a) Well curb (RCC M-35) b) Well Steining (RCC M-35) 27x/4(12-8)x2 c) Bottom Plug (PCC M-30) d) Intermediate Plug (PCC M-30) e) Well Cap (RCC M-35) 4 Sinking of well 0 to 3 m 3 to 10 m 10 to 20 m 20 to 30 m Sand fill 7 x /4 x 8 x 26.4 Reinforcement in foundation (HYSD bars): Well Curb mm dia 2 8.5 12 mm dia 12 2 1.8 mm dia 20 2 28.5 Steining 28 28 12 12 Abutment well cap 32 32 32 32 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 2 2 2 160 140 135 135 120 120 60 60 32.5 32.5 38.5 2.5 9.1 8.5 9.1 8.5 4.84 4.84 0.89 0.89 6.32 6.32 6.32 6.32 TotalTotal3.94 0.23 0.6 12

Unit Nos. m 2 60 129.60 T 2 129.60 m


3 3

Qty for 2Lane 0.00 0.00 15552.00 15.55 259.20 3392.92 466.24

233.12

m3 3 m

2 2

15.08 192.82 Total-

m3 m3

30.16 385.64 385.64 6.00 14.00 20.00 20.00 2654.02

2 2 2 2

3 7 10 10

m m m m m3

5 6

188

188 41

0.89 Kg 0.89 Kg 2.47 Kg

2840.89 3609.60 5770.37

2 1

Kg Kg Kg Kg Kg Kg Kg Kg Kg Tonne
m3 3 m m3 m3

50330.86 44039.51 18480.00 600.00 13805.04 12894.81 6902.52 6447.41 165721.01 165.72
28.37 5.52 9.42 101.70 145.01

Sub structure (RCC M-35) Dirt wall Abutment Cap Return wall Abutment

2 2 4 2

0.3 12 4 1+1.5 2

12 1 3.27 3.39

0.3

Reinforcement in substructureDirt wall Return wall

2 4

2007 620

kg kg

4014.00 2480.00

Abutment Cap Abutment32 32 32 12 12

2 mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2

600 6.22 6.22 9.61 23 23 97 49 48 32.1 97 6.32 6.32 6.32 0.89 0.89 TotalTotal-

kg kg kg kg kg kg kg Tonne Tonne Tonne m3 m3 m3 T T

1200.00 7627.41 3853.02 5831.49 1312.53 5294.91 31613.36 31.613 776.00 776.00 510.00 0.00 510.00 64.30 64.30 20.7

1.5

9 Roller bearing10 Rocker Bearing11 Super struture (PSC M-40)

1 1

4 4 1

194.00 194.00 510.00

12 Reinforcement bar in super structure (TMT CRS) 1 13 HTS Stand 14 Wearing coat(Mastic Asphtl)1 15 16 17 18 19 20 21 22 23 24 25 26 27 RCC RailingStrip seal Expansion JointCrash barrier Back fill behind abutment Leveling course (M-15) (Below approach slab)Weep holes Drainage spout Apprpoach slab (M25) Painting Soler stud 8.5 55.84 1 2 2 7.55 20 4 4 55.84 1 1 2 55.48 12 55.48 12 Sqm Rm m 5.21 m3 28.8 m3 Nos. Sqm 12 m3 Sqm 4 Nos. Nos. Sqm m 474.64 55.48 24.00 110.96 944.05 28.80 40.00 4.00 28.80 167.52 4.00 60.00 8.64 111.68 1 64.3 20.7

2 2 1 2 3

0.3

RPM Sign board Hand rail for crash Barrier :

60 8.64 55.84

Executive Engineer, PWD Nagaon NH Division, Nagaon

Protection work of Bridge at chainage- 231240 m


Item Descriptions Unit Estmated Quantity Rate in Rs. Amount in Rs

1 2 1/15 Providing and laying filter material .5 underneath pitching in slopes complete as per drawing and technical specifications.

Cum 2/15 Providing and laying pitching on slop laid .4 over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . a) Stone/Boulder

2134.720

1862.00

3974848.64

Cum 3/15 Providing nad laying boulder apron on river .1 bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical specifications.

1642.930

1463.00

2403606.59

Cum

4040.790 1463.00 Total cost (in Rs.) :

5911675.77 12290131

Executive Engineer, PWD Nagaon NH Division, Nagaon

Item 1 1/15.5

Descriptions 2 Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications.

Unit 3

Estmated Quantity 4

Rate in Rs. 5

Cum 2/15.4 Providing and laying pitching on slop laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . a) Stone/Boulder

2134.720

1862.00

Cum 3/15.1 Providing nad laying boulder apron on river bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical specifications.

1642.930

1463.00

Cum

4040.790 1463.00 Total cost (in Rs.) :

Amount in Rs 6

3974848.64

2403606.59

5911675.77 12290131

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing br no- 241/1 Ch- 240272
Item No. Particulars/Descrption of items 2 Foundation
Providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. Well. (A) 'Assuming depth of water 1.0 m and height of Each island to be 1.25m. (c)'Providing and constructing one span service road to reach island location from one pier location metre to another pier location 2/12.10 Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation Tonne complete as per drawing and technical specification. 3/12.11 Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. (A) 'Well curb 1/12.9

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

9.00 162.00

57977.00 2472.00

521,793.00 400,464.00

85.54

101302.00

8,664,968.00

(iv)'RCC M35 Grade


Case II : With Batching Plant, Transit Mixer and Cum 1425.60 Concrete Pump (B) 'Well steining (viii) 'RCC M35 Grade Case II : With Batching Plant, Transit Mixer and Cum 18661.06 Concrete Pump (C)'Bottom Plug (iii) 'PCC Grade M30 Case II : With Batching Plant, Transit Mixer and Cum 2565.53 Concrete Pump (D) 'Intermediate plug (iii) 'Grade M30 PCC Case II : With Batching Plant, Transit Mixer and Cum 165.88 Concrete Pump (F) 'Well cap (iv) 'RCC Grade M35 Case II : With Batching Plant, Transit Mixer and Cum 1912.40 Concrete Pump 4/12.18 Sinking of 12 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing metre and technical specifications. Depth of sinking is rekonewed from bed level. A. Sandy soil (i) Depth below bed level upto 3.0 M (ii) 'Beyond 3m upto 10m depth (iii) 'Beyond 10m upto 20m (iv) 'Beyond 20m upto 30 m (a) For sinking

10003.00

14,260,277.00

9169.00 171,103,263.00

8924.00

22,894,790.00

8133.00

1,349,103.00

9030.00

17,268,972.00

metre metre metre metre

33.00 77.00 110.00 110.00

46710.00 51791.00 68400.00 128301.00

1,541,430.00 3,987,907.00 7,524,000.00 14,113,110.00

Item No.

Particulars/Descrption of items 2

Unit 3
cum

Total Quantity 4 14597.10

Rate in Rs. 5 1798.00

Amount (Rs.) 6 26,245,579.00

5/12.21 Sand filling in wells complete as per drawing and technical specifications 6/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant reinforcement bar of Fe-500 N/mm2 Steel (CRS)

tonne

1285.93

73279.00

94,232,008.00

Subsructure
7/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999 (H) 'RCC Grade M35 Case-II : 'With Batching Plant, Transit Mixer and Concrete Pump Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

Cum

681.89

9169.00

6,252,210.00

8/13.6

(i) TMT Corrosion Resistant Steel (CRS) Tonne 169.63 reinforcement bar of Fe-500 N/mm2 9/13.12 Supplying, fitting and fixing in position true to line and level forged steel roller bearing conforming to tonne IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH 5400.00 capacity specifications complete including all accessories as per drawing and Technical Specifications. 10/13.11 Supplying, fitting and fixing in position true to line and level cast steel rocker bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH tonne 5400.00 specifications complete including all accessories as capacity per drawing and Technical Specifications.

73343.00

12,441,082.00

1191.00

6,431,400.00

953.00

5,146,200.00

Superstructure
11/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. (E) 'PSC Grade M-40 Case II : 'Using Batching Plant, Transit Mixer and Concrete Pump (ii) 'For T-beam & slab (a) Height upto 5m

Cum

3320.00

10920.00

36,254,400.00

Item No.
12/14.2

Particulars/Descrption of items 2
Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

Unit 3

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

(i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 13/14.3 High tensile steel wires/strands including all accessories for stressing, stressing operations and Tonne grouting complete as per drawing and Technical Specifications 14/14.5 Mastic Asphalt (A) Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal sqm size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515. 15/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space metre between vertical posts for expansion, complete as per approved drawings and technical specifications. 16/14.22 Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their metre authorised representative ensuring compliance to the manufacturer's instruction for installation). 17/8.4 Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular

419.00

77554.00

32,495,126.00

126.00

167708.00

21,131,208.00

2875.04

329.00

945,889.00

338.24

2044.00

691,363.00

132.00

11804.00

1,558,128.00

Sqm

8.64

5200.00

44,928.00

Item No.

Particulars/Descrption of items

Unit

Total Quantity 4

Rate in Rs. 5

Amount (Rs.) 6

2 3 Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 19/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The metre thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I)
18/8.22 Reinforced 20/13.9 Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification (A) 'Granular material 21/13.8 Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification. 22/14.9 Drainage Spouts complete as per drawing and Technical specification 23/14.10 leveling course below approach slab complete as per drawing and Technical specification' (PCC M15 Grade) 24/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification (A) With TATA make TMT CRS (Fe-500) grade 25/14.16 rebar Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. )

676.48

4170.00

2,820,922.00

676.48

1475.00

997,808.00

Cum

837.28

1524.00

1,276,020.00

Each

40.00

204.00

8,160.00

Each Cum

40.00 28.80

10197.00 5498.00

407,880.00 158,343.00

Cum

28.80

12025.00

346,320.00

Item No.

Particulars/Descrption of items 2

Unit 3 RM

Total Quantity 4 1014.72

Rate in Rs. 5 160.00

Amount (Rs.) 6 162,356.00

(B) For RCC Railing 26/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).

a) Bi-directional Studb) Uni-directional Stud27/8.51 Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&Hs fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.

Each Each

4.00

3500.00 3400.00

13,600.00

Each

100.00

298.00

29,800.00

28

Protection work Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications. Cum Providing and laying pitching on slop laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . Cum a) Stone/Boulder Providing nad laying boulder apron on river bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical Cum specifications. 888.990 1862.00 1655300.00

29

2666.980

1463.00

3901792.00

30

5007.860 1463.00 7326500.00 Total cost (in Rs.) : 526,604,399.00

Executive Engineer, PWD Nagaon NH Division, Nagaon

513,720,807.00

12883592.00

Quantity Calculation fo Br. No.241/1 Ch-240272,L- 1x9m


Sl. No. 1 (i) Temporary Island 24m dia (ii) Service Road 2 Cutting edge 3 PCC/RCC work in well foundation : a) Well curb (RCC M-35) b) Well Steining (RCC M-35) 11x/4(12- 8)x27 c) Bottom Plug (PCC M-30) d) Intermediate Plug (PCC M-30) e) Well Cap (RCC M-35) 11 2 9 15.08 192.82 169.64 m m3 m3 Total- m3 m m m m m3
3

Unit

Qty for 2Lane 9.00 162.00 85536.00 85.54 1425.60 18661.06 2565.53

11

1 9 60.00

9 Nos. 3 18 m 129.60 kg T m
3

11 129.60

11

233.23

m3 3 m

165.88 385.64 1526.76 1912.40 33.00 77.00 110.00 110.00 14597.10

4 Sinking of well 0 to 3 m 11 3 to 10 m 11 10 to 20 m 11 20 to 30 m 11 5 Sand fill 11 x /4 x 8 x 26.4 6 Reinforcement in foundation (HYSD bars): Well Curb mm dia 11 8.5 188 12 mm dia 12 11 1.8 188 mm dia 20 11 28.5 16 Steining 20 20 20 20 12 12 Abutment well cap 28 28 20 20 Pier 32 28 mm dia mm dia 9 9 120 96 8 8 mm dia mm dia mm dia mm dia mm dia mm dia 2 2 9 9 11 11 200 180 200 180 135 135 32.5 32.5 32.5 32.5 38.5 2.5

3 7 10 10

0.89 0.89 2.47

Kg Kg Kg

15624.89 19852.80 12385.19

2 180

2.47 2.47 2.47 2.47 0.89 0.89

Kg Kg Kg Kg Kg Kg

32098.77 28888.89 144444.44 130000.00 101640.00 594000.00

mm dia mm dia mm dia mm dia

2 2 2 2

120 120 120 120

9.1 8.5 9.1 8.5

4.84 4.84 2.47 2.47

Kg Kg Kg Kg

10569.48 9872.59 5392.59 5037.04

2 2

6.32 4.84 TotalTotal-

Kg Kg Kg Tonne

109226.67 66901.33 1285934.68 1285.935

7 Sub structure (RCC M-35)

Sl. No. 7
Dirt wall Abutment Cap Return wall Abutment Pier Cap Pier 8 Reinforcement in substructureDirt wall Return wall Abutment Cap Abutment32 mm dia 32 mm dia 32 mm dia 12 mm dia 12 mm dia Pier Cap Pier 32 12 mm dia mm dia 2 9 9 26.8 78 16 5.94 6.32 0.89 TotalTotal2 2 4 2 9 9 0.3 0.23 0.6 1+1.5 2 27 2.36 3.36 1 3.27 3.13 12 12 4 12

Unit

Qty for 2Lane


24.19 5.52 9.42 93.90 243.000 305.856 681.886 4014.00 2480.00 1200.00 7308.58 5544.14 4596.12 1008.00 5432.00 81900.00

0.3

m 3 m 3 m m3

1.20

12

m3 m3 Total- m3 kg kg kg

2 4 2 2 2 2 2 2 9

2007 620 600 5.96 8.95 5.96 27 97 9100 97 49 61 21 21 6.32 6.32 6.32 0.89 0.89

1.5

kg kg kg kg kg kg

kg kg kg Tonne Tonne Tonne m3

52715.520 3430.400 169628.754 169.629 5400.00 5400.00 3320.00 419.00 419.00 0 126.00 2875.04 338.24 132.00 676.48 837.28 28.80 40.00 40.00 28.80 1014.72 4.00 100.00 8.64 676.48

9 10 11 12

Roller bearing10 Rocker Bearing10 Super struture (RCC M-40) Reinforcement bar in super structure (TMT CRS) -

4 4 10

135.00 135.00 332.00 10

41.9 T T 10 12.6 Sqm Rm m 6.709 m3 28.8 m3 Nos. Sqm 12 m3 Sqm 4 Nos. Nos. Sqm m

13 HTS Stand 14 Wearing coat(Mastic Asphtl)15 16 17 18 19 20 21 22 23 24 25 26 27 1 8.5 338 RCC Railing1 Strip seal Expansion Joint11 Crash barrier 2 Back fill behind abutment 2 5.20 Leveling course (M-15) (Below approach slab)Weep holes 2 Drainage spout 10 Apprpoach slab (M25) 2 4 Painting 3 Soler stud RPM 1 Sign board 2 Hand rail for crash Barrier : 2 338.24 12 338.24 12
20 4

0.3 338.24 1.00 100 4.32 338.24

Sl. No.

Unit

Qty for 2Lane

Executive Engineer, PWD Nagaon NH Division, Nagaon

Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing br no- 209/1 Ch- 208415 m
Rate in Total Rs. Quantity 4 5

Item No. 1

Particulars/Descrption of items 2
Part-A. : BRIDGE PROPER

Unit 3

Amount (Rs.) 6

Foundation
1 /12.9 Providing and constructing temporary island 20m diameter for construction of well foundation for 12m dia. Well complete as per Drawing and MoSRT&H's Technical Specification Nos. 1200 . A) Assuming depth of water 1.0 m and height of island to be 1.25m. B) Assuming depth of water 4.0m and height of island 4.5m. C) Providing and constructing one span service road to reach island location from one pier location to another pier location. Well Foundation Providing and Laying Cutting Edge of Mild Steel weighing 40 kg per metre for Well Foundation complete as per Drawing and MoSRT&H's Technical Specification Nos. 1200 & 1900. Plain/Reinforced Cement Concrete, in Well Foundation complete as per Drawing and MoSRT&H's Technical Specificationcl Nos. 1200,1500 & 1700 A. Well Curb IV) RCC M - 35 grade Case - I : Using concrete mixer. B. Well steining VIII) RCC M- 35 grade Case I : Using concrete mixer. C. Bottom Plug IV) PCC grade M-35 Case - I : Using concrete mixer. D. Intermediate plug lII) PCC grade M - 30 Case - I : Using concrete mixer. F. Well Cap IV) RCC M - 35 grade Case - I : using concrete mixer. Sinking of 12m external diameter well (other than pneumatic method of sinking ) through all types of soil strata namely sandy soil,clayey soil and rock complete as per Drawing as per MORTH Section No. 1200 . A. Sandy soil I) Depth below Bed level up to 3.0m II) Beyond 3.0 m upto 10.0 m III) Additional depth beyond 10m up to 20m IV)Additional depth beyond 20m up to 30m. With Kentledge.
(a) For sinking

each each metre

0.00 1.00 42.00

57977.00 885693.00 2472.00

0.00 885693.00 103824.00

2 /12.10

MT

19.45

101302.00

1970324.00

3 /12.11

Cum

389.04

8319.00

3236424.00

Cum

4146.92

7626.00

31624412.00

Cum

699.690

7356.00

5146920.00

Cum

45.240

6888.00

311614.00

Cum

605.680

7140.00

4324556.00

4/12.18

Metre Metre Metre Metre

9.00 21.00 30.00

46710.00 51791.00 68400.00

420390.00 1087611.00 2052000.00

15.00

128301.00

1924515.00

5 /12.21

Sand Filling in Wells complete as per drawing and as per Technical Specification as per MORTH Cum Section No. 1207 .

3242.130

1798.00

5829350.00

Item No.

Particulars/Descrption of items

Unit 3 MT

Rate in Total Rs. Quantity 4 5

Amount (Rs.) 6

1 2 6 / 12.40 Reinforcement in Foundation: Supplying,

fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2

338.40

73279.00

24797614.00

Substructure
7 / 13.5 (B) Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications cl. no. 1500,1700 & 2200 including providing plasticiser ( Masterplast PL-1 SPL-2 OR equivalennt)air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS: 1903-1999 and steel shuttering formwork H) RCC Grade M 35 Cum b)Height 5.0m to 10.0m Case-I : Using Concrete Mixer
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2

220.35

8801.00

1939292.00

8 / 13.6

MT

32.30

73343.00

2368979.00

9 / 13.11 Supplying, fitting and fixing in position true to line and level cast steel rocker bearing conforming to IRC: 83(Pt.-I) section IX and clause 2003 of tonne MoRTH specifications complete including all accessories as per drawing and Technical Specifications. Supplying, fitting and fixing in position true to line and level forged steel rocker bearing conforming to IRC: 83(Pt.-I) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical 10/13.12 Specifications. tonne

1550.00

953.00

1477150.00

1550

1191.00

1846050.00

Superstructure
11/ 14.1 Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification including providing plasticiser ( Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS: 1903-1999 and steel shuttering formwork as per specification and direction of Engineer in charge. D. RCC/PSC grade M - 35 Case I : Using concrete mixer (ii)For T beam and slab, b) Height 5.0m to 10.0 m Cum
and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel

1016.00

8889.00

9031224.00

12/ 14.2 Reinforcement in Super Structure: Supplying, fitting

Item No. 1

Particulars/Descrption of items 2

Unit 3

Rate in Total Rs. Quantity 4 144.62 5 77554.00

Amount (Rs.) 6 11215860.00

(i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2

High tensile steel wires/strands including all accessories for stressing,stressing operations and grouting complete as per drawing and Technical specifications. 14/14.4 Providing and laying cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical specification of section 1800 of MORTH Specification of Roads and Bridge Work . 15 / 14.22 Providing Strip Seal Expansion (Providing and laying strip seal expansion joint catering to maximum horizontal movement upto 70mm complete as per drawing and clause no 2607 of MORTH Specification of Roads and Bridge Works for superstructure works to be installed by the manufacturer / supplier or their authorise representative ensuring compliance to the manufacturer's instruction for installation. 16 /8.22 RCC Crash Barrier (provosion of an RCC crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/ TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia, 450mm long at expansion joints filled with pre moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circular No. RW/ NH 33022/ 1/ 94-DO III dated June 1994 as per B. M 40 grade concrete 17 / 14.9 Providing Drainage Spouts complete as per approved drawing and technical specifications clause 2705 of MORTH Specification of Roads and Bridge Works for superstructure works Miscellaneous Works 18 / 13.9 Back filling behind abutment, wing wall and return wall complete as per drawing and clause no 710.1.4 of IRC:78 & 2200 MORTH Specification. (A) Granular material 13/14.3

Tonne

48.4

167708.00

8117068.00

Cum

1086.960

12993.00

14122872.00

Metre

44.40

11804.00

524098.00

Metre

207.04 Nos 10.00

4170.00 10197.00

863357.00 101970.00

Cum

778.98

1524.00

1187166.00

19 /14.10 PCC M15 Grade levelling course below approach slab complete as per approved drawing and Cum technical specifications clause 2700 of MORTH Specification. 20 / 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Cum
Technical specification (A) With TATA make TMT CRS (Fe-500) grade rebar

34.08

5498.00

187372.00

34.08

12025.00

409812.00

21 /13.8

Providing weep holes in brick masonry ,plain/Reinforcement concrete abutment,wing wall/return wall with 100mm dia AC pipe,extending through the full width of the structure with slope of each 1V:20H towards drrawing force complete as per approved drawing and technical specifications.

40.00

204.00

8160.00

Item No.

Particulars/Descrption of items

Unit 3

Rate in Total Rs. Quantity 4 5

Amount (Rs.) 6

1 2 22 /14.16 Painting on concrete surface (providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust,oil,grease,efflorescence and applying paint @ of 1 litre for 2 Sqm.) complete as per drawing and technical specifications clause 800 of MORTH Specification of Roads and Bridge Works for superstructure works
(B) For RCC Railing

23/8.47 Providing

Rm Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per Each minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).

207.04

160.00

33127.00

b) Uni-directional Stud-

4.00

3400.00

13600.00

Direction and place identification sign more than 0.9sqm size board. Providing and erecting direction and place identification retro-Reflectrorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3 fixed over aluminium sheeting, 2mm thick with area exceeding 0.9sqm fixed on an sqm angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm, 2 nos. firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. . ( All the Steel work 25/8.51 Providing reflective pavement marker with a provision of spike at the bottom with Micro Prismatic lens in both direction having thermoplastic body adhering to the specification Each and guidelines of MORT&H's fixed to the road surface using the adhesive and the procedures recomment warranty and free maintenance. Providing 26/Analysis rate HAND RAIL : and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the meter drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only

24/8.6

8.64

11000.00

95040.00

100.00

298.00

29800.00

207.74

1475.00

306417.00

Item No. 1 27/14.6

Particulars/Descrption of items

Unit

Rate in Total Rs. Quantity 4 5

Amount (Rs.) 6

2 3 Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between meter vertical post not to exceed 2000mm,leaving adequate space between vertical posts for expansion,complete as per approved drawings and technical specification.

207.74

2100.00

436254.00

Protection Work 1 Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications . 0.3*9.32*[26.2+[4*40]+[2*14.8]]=603.38 Cum 2 Providing and laying pitching on slope laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specifications . a ) Stone / Boulder 0.5*9.32*[26.2+[4*40]+[2*14.8]]=1005.63 Cum 3 Providing and laying boulder apron on river bed for protection against scour with stone/ boulders weighing not less than 40 kg each complete as per drawing and drawing technical specifications . 5.0*[1.2+0.8]/2*[[68.09+[4*40]+[2*14.8]]=1288.45 Cum 1288.45 1463.00 1885002.35 142,509,647.60 1005.630 1463.00 1471236.69 603.380 1862.00 1123493.56

Total Cost (in Rs.) :

Executive Engineer, PWD Nagaon NH Division, Nagaon

142,509,647.60

Quantity Calculation Br. No :229/1,Ch. 208415 m


Sl. No. 1 Earth work in excavation for foundation Unit Qty for 2Lane 0.00 0.00 0.00 0.00 1 42.00 19452.00 19.45 389.04 4146.91 699.69 45.24 436.04 169.64 605.68 9.00 21.00 30.00 15.00 3242.13 Qty for 4Lane

2 3 4

i) Temporary Island ii) Service Road Cutting edge

m m3 m3 m3 Nos. m 3 50 129.68 T

0.00 2.00 84.00 38.90 778.08 8293.82 1399.38 90.48

PCC/RCC work in well foundation: a) Well curb (RCC M-35) 3 b)Well Steining (RCC M-35) 3 /4(122-82) c) Bottom Plug (PCC M-30) 3 d) Intermediate Plug (PCC M-30) 3 e) Well Cap (RCC M-35) 2 1 Sinking of well 0 to 3 m 3 to 10 m 10 to 20m 20 to 25 m Sand fill =

129.68 22 233.23 15.08 218.02 169.64

m3 m3 m3 m3 m3 m3 m3 m m m m m3

1211.36 18.00 42.00 60.00 30.00 6484.26

3 3 3 3

3 7 10 5

6 7

3 x /4 x 82 x 21.5 Reinforcement in foundation (HYSD bars): Well Curb 12 3 140 8.4 12 3 140 1.2 6 20 3 16 32.5

0.89 Kg 0.89 Kg 2.47 Kg Kg Kg Kg Kg 4.84 4.84 0.89 0.89 6.32 6.32 2.47 2.47 Kg Kg Kg Kg Kg Kg Kg Kg

3139.920 2691.360 3853.200 0.000 0.000 0.000 0.000 67881.000 63888.000 26726.700 131577.600 10636.560 11387.376 5394.480 5394.480 8089.600 4646.400 345306.68 690613.352 345.307 690.613

Steining 28 28 12 12 Abutment well cap 32 32 20 20 Pier well cap 32 28 1 1 160 120 8 8 6.32 Kg 4.84 Kg Kg T 2 2 2 2 99 99 120 120 8.5 9.1 9.1 9.1 3 3 3 3 170 160 154 154 27.5 27.5 32.5 160

2 2

Sub structure (RCC M-35) Dirt wall = 2 0.3 14.8 3.86 Abutment cap = 2 14.82 Return wall = 2 x 2((0.60 x 4) + (2.67 x 4)/2) x 0.30 Abutment = 2 1.2 2 14.8 Pier Cap = 1 32.904 Pier = 2 1.5 1.2 12 Reinforcement in substuctureDirt wall = Return wall Abutment Cap Abutment Pier 2x 2x 2.1= 2=

m3 m3 3 m m3 3 m 3 m 3 m

34.277 29.640 9.29 71.04 32.904 43.200 220.349 4100.000 4200.000 4000 12000.000 8000.000 32300.000 32.300 1550 1550 1016 1016.00 144.62 144.62 48.4 1086.96 207.04 44.40 207.04 778.99 34.08 40 10 34.08 207.04 4 100 8.64 207.04

440.6976

4.1 T 4.2 T 4T 12 T 8T

1.58 Kg Kg Kg 6.32 Kg Kg Kg T 155.00 155.00 508 T T m3

64600 64.600 3100 3100 2032.000

10 Roller Bearing = 11 Rocker Bearing = 12 Super structure (RCC M-40) =

2 2

5 5 2

13 Reinforcement bar in super structure (TMT CRS): = 2 72.31 14 Reinforcement bar in super structure (High tensile steel): = 2 24.2 15 Wearing coat (Mastic Asphalt): = 1 10.5 103.5 16 17 17 18 19 20 21 22 23 24 25 26 27 RCC Railing: = 2 103.52 Strip seal Expansion Joint: = 3 14.8 Crash Barrier 2 104 Back fill behind Abutment:= 2 5.20 14.8 Leveling course: (M-15) (Below approach slab):= Weep holes = Drainage spout = Approach slab (M-25): Painting Solar stud: RPM Sign Board Hand rail 2 2 2 20 5 103.5 1 2 2 100 4.32 103.52

T T T Sqm Rm m 5.061 m3 m Nos. Sqm m3 m Nos. Nos. Sqm Sqm


3

289.240 96.800 2173.920 414.080 88.800 414.080 1557.978 68.160 80.000 20.000 68.160 414.080 8 200 17.280 414.080

Executive Engineer, PWD Nagaon NH Division, Nagaon