Sl No.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52
Bridge Name
Repairing Estimate Bridge no : 213/1 Quantity Calculation Bridge no : 213/1 Repairing Estimate Bridge no : 223/4 Quantity Calculation Bridge no : 223/4 Repairing Estimate Bridge no : 228/1 Quantity Calculation Bridge no : 228/1 Repairing Estimate Bridge no : 229/1 Quantity Calculation Bridge no : 229/1 Repairing Estimate Bridge no : 234/1 Quantity Calculation Bridge no : 234/1 Repairing Estimate Bridge no : 235/3 Quantity Calculation Bridge no : 235/3 Repairing Estimate Bridge no : 237/1 Quantity Calculation Bridge no : 237/1 Repairing Estimate Bridge no : 240/1 Quantity Calculation Bridge no : 240/1 Repairing Estimate Bridge no : 245/3 Quantity Calculation Bridge no : 245/3 Repairing Estimate Bridge no : 250/4 Quantity Calculation Bridge no : 250/4 Repairing Estimate Bridge no : 251/1 Quantity Calculation Bridge no : 251/1 Repairing Estimate Bridge no : 252/1 Quantity Calculation Bridge no : 252/1 Repairing Estimate Bridge no : 255/1 Quantity Calculation Bridge no : 255/1 Repairing Estimate Bridge no : 255/2 Quantity Calculation Bridge no : 255/2 Repairing Estimate Bridge no : 259/1 Quantity Calculation Bridge no : 259/1 Repairing Estimate Bridge no : 259/2 Quantity Calculation Bridge no : 259/2 Repairing Estimate Bridge no : 259/3 Quantity Calculation Bridge no : 259/3 Repairing Estimate Bridge no : 260/1 Quantity Calculation Bridge no : 260/1 Repairing Estimate Bridge no : 260/2 Quantity Calculation Bridge no : 260/2 Repairing Estimate Bridge no : 260/4 Quantity Calculation Bridge no : 260/4 Repairing Estimate Bridge no : 260/5 Quantity Calculation Bridge no : 260/5 Repairing Estimate Bridge no : 260/6 Quantity Calculation Bridge no : 260/6 Repairing Estimate Bridge no : 264/1 Quantity Calculation Bridge no : 264/1 Repairing Estimate Bridge no : 264/2 Quantity Calculation Bridge no : 264/2 Repairing Estimate Bridge no : 265/1 Quantity Calculation Bridge no : 265/1 Repairing Estimate Bridge no : 266/1 Quantity Calculation Bridge no : 266/1
Page no
2-5 6-8 9 - 12 13 - 15 16 - 19 20 - 22 23 - 26 27 - 29 30 - 33 34 - 36 37 - 40 41 - 43 44 - 48 49 - 51 52 - 55 56 - 57 58 - 61 62 - 64 65 - 68 69 - 71 72 - 75 76 - 78 79 - 82 83 - 85 86 - 89 90 - 92 93 - 96 97 - 99 100 - 103 104 - 105 106 - 109 110 - 112 113 - 116 117 - 119 120 - 123 124 - 126 127 - 130 131 - 132 133 - 136 137 - 139 140 - 143 144 - 146 147 - 150 151 - 153 154 - 157 158 - 160 161 - 164 165 - 167 168 - 171 172 - 174 175- 178 179 - 181
Bridge Name
Abstract Cost Estimate Bridge No : 209/1 Quantity Calculation Bridge No : 209/1 Cost Estimate Bridge No : 213/1 Quantity Calculation Bridge No : 213/1 Cost Estimate Bridge No : 223/4 Quantity Calculation Bridge No : 223/4 Cost Estimate Bridge No : 226/1 Quantity Calculation Bridge No : 226/1 Cost Estimate Bridge No : 228/1 Quantity Calculation Bridge No : 228/1 Cost Estimate Bridge No : 229/1 Quantity Calculation Bridge No : 229/1 Cost Estimate Bridge No : 232/1 Quantity Calculation Bridge No : 232/1 Cost Estimate Bridge No : 234/1 Quantity Calculation Bridge No : 234/1 Cost Estimate Bridge No : 235/3 Quantity Calculation Bridge No : 235/3 Cost Estimate Bridge No : 237/1 Quantity Calculation Bridge No : 237/1 Cost Estimate Bridge No : 240/1 Quantity Calculation Bridge No : 240/1 Cost Estimate Bridge No : 241/1 Quantity Calculation Bridge No : 241/1 Cost Estimate Bridge No : 245/3 Quantity Calculation Bridge No : 245/3 Cost Estimate Bridge No : 250/4 Quantity Calculation Bridge No : 250/4 Cost Estimate Bridge No : 251/1 Quantity Calculation Bridge No : 251/1 Cost Estimate Bridge No : 252/1 Quantity Calculation Bridge No : 252/1 Cost Estimate Bridge No : 255/1 Quantity Calculation Bridge No : 255/1 Cost Estimate Bridge No : 255/2 Quantity Calculation Bridge No : 255/2 Cost Estimate Bridge No : 259/1 Quantity Calculation Bridge No : 259/1 Cost Estimate Bridge No : 259/2 Quantity Calculation Bridge No : 259/2 Cost Estimate Bridge No : 259/3 Quantity Calculation Bridge No : 259/3 Cost Estimate Bridge No : 260/1 Quantity Calculation Bridge No : 260/1 Cost Estimate Bridge No : 260/2 Quantity Calculation Bridge No : 260/2 Cost Estimate Bridge No : 260/4 Quantity Calculation Bridge No : 260/4 Cost Estimate Bridge No : 260/5 Quantity Calculation Bridge No : 260/5 Cost Estimate Bridge No : 260/6 Quantity Calculation Bridge No : 260/6
Page No
1-4 5-9 10 - 11 12 - 15 16 - 18 19 - 22 23 - 25 26 - 29 30 - 31 32 - 35 36 - 38 39 - 42 43 - 45 46 - 50 51 - 52 53 - 56 57 - 59 60 - 63 64 - 66 67 - 70 71 - 73 74 - 77 78 - 80 81 - 85 86 - 87 88 - 91 92 - 94 95 - 98 99 - 101 102 - 105 106 - 108 109 - 112 113 - 115 116 - 119 120 - 122 123 - 126 127 - 129 130 - 133 134 - 136 137 - 140 141 - 143 144 - 147 148 - 150 151 - 154 155 -157 158 - 161 162 - 164 165 - 168 169 - 171 172 - 175 176 - 178 179 - 182 183 - 185
Sl No
54 55 56 57 58 59 60 61 62
Bridge Name
Cost Estimate Bridge No : 264/1 Quantity Calculation Bridge No : 264/1 Cost Estimate Bridge No : 264/2 Quantity Calculation Bridge No : 264/2 Cost Estimate Bridge No : 265/1 Quantity Calculation Bridge No : 265/1 Cost Estimate Bridge No : 266/1 Quantity Calculation Bridge No : 266/1 Annexure-I
Page No
186 - 189 190 - 192 193 - 196 197 - 199 200 - 203 204 - 206 207 - 210 211 - 213 214
Index
Sl No. 1 2 3 4 5
Bridge Name Abstract of Cost for ROB Cost Estimate for ROB No. 222/1 Cost Estimate for ROB No. 227/1 Cost Estimate for ROB No. 238/2 Cost Estimate for ROB No. 243/1
Page No. 1 2 3 4 5
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam.
Abstract of Bridge
Sl no
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Chainage 208415 212964 222595 225454 227462 228087 231240 233214 234859 236259 239322 240272 244803 249990 250350 251630 254000 254750 258170 258380 258590 259015 259230 259580 259685 259870 Bridge Number 209/1 213/1 223/4 226/1 228/1 229/1 232/1 234/1 235/3 237/1 240/1 241/1 245/3 250/4 251/1 252/1 255/1 255/2 259/1 259/2 259/3 260/1 260/2 260/4 260/5 260/6 Foundation Substructure Superstructure 83715247 3843254 7490574 244385207 6465518 5996341 65021408 4931416 6536365 4360989 4056387 384107664 3568408 4674659 5410407 3146003 3314720 5242120 3174818 2966473 11491302 7056378 6602668 4445961 4191425 4841176 7631471 4361152 5663192 23916554 11477347 10441881 5311920 8773643 5794902 3019475 6086571 30270892 3266608 3966948 3043138 2186448 5161212 2220405 1290626 1955483 7172930 3516355 8643895 2586142 2674023 2464563 46683197 4996144 7657806 84373397 7688495 7360981 17303325 5345836 7660685 4131320 5259062 99342251 5381863 5451262 5871868 4660377 4822344 5654614 4556071 4704570 10273280 8207648 6165614 5632670 5652421 5332024 Protection work 4479733 1661894 1376013 10811927 1441941 1592802 12290131 1353616 1220261 738296 1068934 12883592 853013 954638 989581 729730 773338 1009724 601683 694720 1866128 1303642 1251493 864840 901225 821020 Total Amount 142509648 14862444 22187585 363487085 27073301 25392005 99926784 20404511 21212213 12250080 16470954 526604399 13069892 15047507 15314994 10722558 14071614 14126863 9623198 10321246 30803640 20084023 22663670 13529613 13419094 13458783
27 28 29 30
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
212964 222595 227462 228087 233214 234859 236259 239322 244803 249990 250350 251630 254000 254750 258170 258380 258590 259015 259230 259580 259685 259870
455,953 649,760 1,335,324 1,188,107 556,737 676,088 413,807 565,880 365,057 393,973 416,105 286,231 331,915 395,253 139,117 230,832 1,015,141 423,335 1,016,838 304,129 324,676 326,470
1,382,460 2,084,142 1,696,710 1,690,820 1,494,203 2,086,432 1,169,230 1,385,178 1,482,814 1,500,684 2,087,088 1,377,954 1,382,054 1,689,338 1,367,871 1,368,238 2,813,056 2,311,053 1,719,776 1,694,206 1,704,987 1,489,713
2,556,575 4,108,818 4,661,187 4,491,861 2,844,471 4,137,031 2,138,488 2,722,252 2,595,898 3,002,973 3,988,906 2,640,276 2,695,328 3,133,305 2,175,567 2,281,333 6,655,776 4,181,691 4,287,263 3,022,390 3,066,604 2,578,787
614,217 647,685 995,378 1,392,045 899,480 900,118 952,754 581,501 610,877 2,592,675 1,310,164 1,395,824 935,252 946,506 675,398
23 24 25 26
Name of work : 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (Total Length = 57.50 km) in Sonitpur district in the state of Assam
Sl. No. 1 2 3 4
Description of Items ROB No. 222/1 ROB No. 227/1 ROB No. 238/2 ROB No. 243/1 Rs. Rs. Rs. Rs. Total Rs.
Annexure-I
Analysis of Rate for Hand Rail
Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 11611979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only
62.38
Kg
55.00
3430.90
14.59
Kg
50.00
729.50
Kg m cm
Add 10% overhead charges Add 10% contractor's profit Cost for 6.75m Cost for 1.00m
28.80 11.25 64.02 270.00 8227.47 822.75 9050.22 905.0217 9955.24 1474.85
Say
Rs.
1475/m
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.213/1,Ch-212964
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of foundation
of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum 2816.778 54.00 152,106.00 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or Cum equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications
135.166 191.616
6514.00 9030.00
880,471.00 1,730,293.00
14.743
73279.00
1,080,384.00
196.320
8120.00
1,594,119.00
126.221
9169.00
1,157,325.00
5/13.6
Item No. 1
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure 6/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete
in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
21.948
73343.00
1,609,708.00
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint Cum 87.140 10591.00 922,900.00
MT
6.08
77554.00
471,219.00
(i)'Providing & fixing 2 mm thick corrugated copper plate metre in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/14.4 Providing and laying Cement concrete wearing coat M30 grade including reinforcement complete as per drawing and Technical Specifications 10/8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians,constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia, 450mm long at expansion joints filled with pre moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circular No. RW/NH-33022/1/94-DO III dated June 1994 as per dimension in the approved drowing and at locations directed by the engineer,all as specified. metre
24.000
1640.00
39,360.00
24.000
558.00
13,392.00
24.000
317.00
7,608.00
24.00
17.00
408.00
152.49
12993.00
1,981,303.00
Item No. 1
Unit 3 metre
11/Analy HAND RAIL metre sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 14/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical Each specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing RM 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall Cum complete as per drawing and technical specification. (A) Granular material Cum 18/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
17.94
2044.00
36,670.00
53.82
160.00
8,612.00
548.26 40.00
1524.00 204.00
835,543.00 8,160.00
Item No. 1
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 21/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15
4 30.00
13,600.00 8,940.00
22/15.11 Flexible Apron :Construction of flexible apron 1 m thick Cum comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at Cum cross drainage works for relatively less important works
301.00
1679.00
505,371.00
Total- 14,862,444.00
Item No. 1
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Item No. 1
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Item No. 1
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
3,843,254.00
4,361,152.00
4,996,144.00
1,661,894.00
2 2 2 2 2
Unit Qty for 2Lane 3 400.68 m 1079.50 10.80 9.31 233.91 67.10 151.83 75.92 156.05 101.22 530.48 2816.78 m3 17.89 16.94 22.37 77.97 135.17 m3 m3 m
3
12.8
12 15
33.74+9.94 2
12.8
12 1.5 1.5 3
m3
12.40
Reinforcement in foundation 25 25 20 20 12 12 m/wall mm dia mm dia mm dia mm dia mm dia mm dia 2 47 47 66 66 10 292 100 11.92 10.86 13.2 13.2 43.88 2 32.4 Total = kg Total = MT kg kg kg kg kg kg 4322.84 1969.21 2151.11 2151.11 390.04 519.11 3240.00 14743.43 14.74 4.92 3.78 106.38 11.14 126.22
13.5
2 2 2 2
0.82 0.7
0.7+1.2 2 0.2+0.45 2
12 12 4.666 3
0.25
m3
3
AbutmentM/wall
13.5
13.6
Supplying, fitting and placing TMT bar Reinforcement in substructure complete as per drawing and technical specifications
Dirt wall -
12 12
2 2 2 2 2 2 2
kg kg kg kg kg kg kg kg
272.00 290.49 221.33 263.11 12909.87 1473.42 5404.44 1113.00 21947.67 21.95 87.14
Abutment cap -
12 12
Abutment-
28 12 12
87.14 m3
14.2
6.076 MT
6.08
10
14.18
12
Nos.
24.00
11
8.22
17.94 m
35.88
12
14.7
8.97
17.94
13
14.16
17.94 m2
53.82
14
14.4
17.94
8.5
m3
152.49
15
14.9
Nos.
2.00
16
13.9
17
14.11
Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material . Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works Curtain wall complete as per drawing and Technical specification
12
4.00
5.711 m3
548.26
0.3
12.00
m3
28.80
18
14.10
0.15
12.00
m3
14.40
19
13.8
20
Nos.
40.00
20
8.51
30
Nos.
30.00
21
8.47
Nos.
4.00
22
15.11
303.66 m3
303.66
23
15.9
301
m3
301.00
24
15.10
100.14 m3 2 17.94 m
100.14 35.88
5633.56
270.33
383.23
29486.86 29.49
252.44
392.64
12.15
48.00
71.76
35.88
107.64
304.98
1096.51
57.60
28.80
80
60
607.32
601.99
200.28 71.76
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.213/1,Ch-212964
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1 Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I.Ordinary Soil B.Mechanical means (ii) With dewatering Cum (i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (P) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum 4/12.40 Supplying, fitting and placing uncoated HYSD reinforcement in foundation complete as per drawing and Technical Specification (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure 5/13.5 Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Unit 3 Total Quantity 4 Rate in Rs. 5 Amount (Rs.) 6
115.34 111.09
356.00 573.00
41,062.00 63,653.00
191.86
54.00
10,361.00
5.22 34.79
6514.00 9030.00
33,994.00 314,154.00
3.48
73279.00
254,938.00
2 3 Case II : With Batching plant, Transit Mixer and concrete Cum Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure 7/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Cum
Item No. 1
Particulars/Descrption of items
Unit
2.76
73343.00
202,647.00
26.98
10591.00
285,724.00
tonne
2.16
77554.00
167,381.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Item Particulars/Descrption of items No. 1 2 10/8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians,constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia, 450mm long at expansion joints filled with pre moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circular No. RW/NH-33022/1/94-DO III dated June 1994 as per dimension in the approved drowing and at locations directed by the engineer,all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.1 Reinforced cement concrete approach slab including 1 reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
35.88 17.94
4170.00 2044.00
149,620.00 36,670.00
Cum
13/14.1 PCC M15 grade levelling course below approach slab Cum 0 complete as per drawing and technical specification. 14/14.9 Drainage Spouts complete as per drawing and Technical Each specification. 15/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Each 17/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
4.00 10.00
3400.00 298.00
13,600.00 2,980.00
Item Particulars/Descrption of items No. 1 2 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
19/16.17 Replacement of Expansion Joints complete as per drawings.
Unit 3 Sqm
metre
17.00 84.49
3628.00 59.00
61,676.00 4,985.00
50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface. 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a) 12 mm dia re-bar fastners 25% of 99 b)16 mm dia re-bar fastners 25% of 99 C) 20 mm dia re-bar fastners 25% of 99 d) 25 mm dia re-bar fastners 25% of 99
Sqm
26.62
614.00
16,343.00
Each
Total- 2,556,575.00
Unit Qty for 2-Lane 57.67 Cm 10 14.915 17.94 3.95 3.95 4.891 Cm Cm Cm Cm Cm Cm 115.34 1.24 2.09 3.59 30.45 1.62 32.84 39.26 111.09 57.46 134.40
2 9.94
3.95
1 Cm Total= Cm 1.65 4 m3 m3
9.95 3.5
3.5 4.8
9.94
3.5
34.79
13.5 Substructure(M35)-
2 2
6.7+1.0 2 0.25
3.15 3.5
Total= 34.79 100 kg 3479.00 Total= kg 3479.00 3.5 Total= Tonne 3 26.19 4.891 m 0.82 m3 Total= m3 1.435 27.63
27.63
100 Kg 2763.00 2763.00 Total= Kg Total= Tonne 2.76 0.82 Total= 80 Total= Total= 2.00 12.00 12.00 12.00 12.00 0.3 26.978 26.978 2158.24 2158.24 Tonne 2.16 Nos. 2.00 m m3 Kg Kg Nos. Nos. Nos. Nos. 3 m 24.00 24.00 24.00 24.00 27.60
3
10 11
1 2 2 2 2 4
12
11.5
11.5
0.3
14
17.94 m
17.94
15
17.94 m
35.88
16
7.5
9.94
74.55
17 18
2.00 8.5
8.5 9.94
metre metre
17.00 84.49
19
13.8
12
Nos.
24.00
20
8.47
Nos.
4.00
21
8.51
10
Nos.
10.00
22
16.28
0.82 2
0.7+1.0 2
2 4.891 1.8
0.25
9.94
Total=
59.321 0.6
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.223/4,Ch-222595
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantit 4
Rate in Rs. 5
Amount (Rs.) 6
197.12 197.14
356.00 573.00
70,175.00 112,963.00
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Cum 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or Cum equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete Cum pump 4/12.40 Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications
317.72
54.00
17,157.00
10.16 67.76
6514.00 9030.00
66,209.00 611,873.00
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 5/13.5 Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m
6.78
73279.00
496,539.00
2 3 Case II : With Batching plant, Transit Mixer and Cum concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Item No. 1
Particulars/Descrption of items
Unit
Tonne
3.94
73343.00
288,752.00
Cum
53.96
10591.00
571,448.00
tonne
4.32
77554.00
334,761.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
Item No. 1
Particulars/Descrption of items 2
Unit 3
Total Quantit 4
Rate in Rs. 5
Amount (Rs.) 6
of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians,constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia, 450mm long at expansion joints filled with pre moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circular No. RW/NH-33022/1/94-DO III dated June 1994 as per dimension in the approved drowing and at locations directed by the engineer,all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
14/14.9 Drainage
metre metre
54.72 27.36
4170.00 2044.00
228,183.00 55,924.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Spouts complete as per drawing and Each Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
16/8.47 Providing Sparkle Solar Road Studs, manufactured by
4.00 56.00
10197.00 204.00
40,788.00 11,424.00
Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 17/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
4.00 18.00
13,600.00 5,364.00
Item No. 1
Particulars/Descrption of items 2 including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
Unit 3 Sqm
19/16.17 Replacement of Expansion Joints complete as per drawings. 20/16.2 Removal of existing asphaltic wearing coat comprising
metre Sqm
25.50 164.56
3628.00 59.00
92,514.00 9,710.00
of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. (a)12 mm dia re-bar fastners 25% of 171 (b)16 mm dia re-bar fastners 25% of 171 (C) 20 mm dia re-bar fastners 25% of 171 (d)25 mm dia re-bar fastners 25% of 171
614.00
16,790.00
Total-
Unit Qty for 2Lane 98.56 15 23.235 27.36 3.95 3.95 4.461 Cm Cm Cm Cm Cm Cm Cm 197.12 1.86 3.25 5.47 60.89 1.62 29.96 17.62 76.47 197.14 146.36 171.36 317.72 10.16 10.16 67.76 67.76 6776.00 6776.00 6.78
1
Raft-
2 1 19.36
19.36 3.5
3.5 6.12
Total= m3 3 12.8 PCC M1519.36 3.5 0.15 m3 Total= 1 3.5 Total= 67.76 kg Total= kg Total= Tonne
19.36
100
13.5 Substructure(M35)2 1 2 0.7+1.0 2 1.0 0.25 3.15 4.46 3.5 100 4.461 3.15 0.82 Total= 39.37 Total= Total= m3 m3 m3 m3 Kg Kg
Tonne
23.89 14.05 1.435 39.37 3937.00 3937.00 3.94 53.956 53.956 4316.48 4316.48 4.32 4.00 36.00 36.00 36.00 36.00
14.1 Superstructure RCC (M25)2 3.5 9.4 0.82 m3 Total= m3 80 Total= Total= 2.00 12.00 12.00 12.00 12.00 Kg Kg
Tonne
53.96
10 11
2.00 3 3 3 3
Sl. Item No. No. 12 14.10 PCC M15 grade levelling course below 13
approach slab complete as per drawing and technical specification 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.
11.5
4 4
0.3 0.3
11.5
14
27.36
27.36
15
27.36
54.72
16
7.5
19.36
145.20
17 18
3 8.5
25.50 164.56
19
28
Nos.
56.00
20
Nos.
4.00
21
18
Nos.
18.00
22
0.8 2
2
0.7+1.0 2
0.25 4.461 1
Total-
19.36
Sl. Item No. No. 23 16.53 Providing, placing and fixing in position
Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.223/4,Ch-222595
Item No. 1 Particulars/Descrption of items Unit 3 Total Quantity 4 Rate in Rs. 5 Amount (Rs.) 6
2 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
Cum
2106.25
54.00
113,738.00
Cum
Cum Cum
291.89 380.79
6514.00 9030.00
1,901,377.00 3,438,561.00
tonne
27.80
73279.00
2,036,898.00
Cum
191.99
8120.00
1,558,959.00
Cum MT
194.55
9169.00
1,783,840.00
Item No. 1
Particulars/Descrption of items 2 (i) TMT Corrosion Resistant Steel reinforcement bar of Fe-500 N/mm2 Super Structure (CRS)
Unit 3 Tonne
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/14.4 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
Cum
174.280
10591.00
1,845,800.00
MT
12.15
77554.00
942,437.00
metre
24.000
1640.00
39,360.00
metre
24.000
558.00
13,392.00
metre
24.000
317.00
7,608.00
metre
24.00
17.00
408.00
232.56
12993.00
3,021,653.00
2 B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 18/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
Item No. 1
Particulars/Descrption of items
metre
27.36
2044.00
55,924.00
Cum Cum,
28.80 14.40
12025.00 5498.00
346,320.00 79,172.00
Each
8.00
10197.00
81,576.00
RM Cum
82.08
160.00
13,133.00
Cum Each
506.98 40.00
1524.00 204.00
772,632.00 8,160.00
Particulars/Descrption of items 2 Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)
(V) 80cmm x 45 cm rectangular
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Each
17.28
5200.00
89,856.00
20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 21/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
4.00 60.00
13,600.00 17,880.00
90.70 206.28
Cum
256.47
1679.00
430,614.00
Total-
22,187,585.00
7,490,574.00
5,663,192.00
7,657,806.00
1,376,013.00
Qty for 2Lane 462.00 580.80 10.80 17.42 215.61 130.68 137.52 68.76 141.34 91.68 249.64 2106.25 33.95 15.70 156.75 43.56 41.93 291.89 325.25 9.00 14.15 32.40 380.79
12.8
12
18.86 1 1
0.15 15.7
m3
3
15 2 30.56+19.36
2
19.36 0.15
12.8
12 12
m m
3 3
18.86 m3 3 m3 Total=
12.40 Reinforcement in foundation = 25 20 12 12 m/wall mm dia mm dia mm dia mm dia 33.00 26.8 10 2 100 120 120 430 32.4 kg kg kg kg 15277.78 7940.74 573.51 764.44 3240.00 27796.47 27.80 4.92 3.78 112.42 2.70 53.53 17.20 194.55 191.99
64.52 kg
2 2 2
0.82 0.7
0.7+1.4 2
0.25
m3
3
Abutment = Pier cap Pier M/wall 6 13.5 Substructure (M20) PCC Wing wall
1 1 2
0.2+0.45 2
13.6
mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia
283.20 290.49 240.00 282.84 120.00 141.42 13866.54 1456.00 5866.67 5042.38 728.00 1600.00 1720.00 31637.54 31.64 174.28
12 12
Pier Cap
12 12
Abutment
28 12 12
6.512 kg 30 1 kg kg kg kg 1 100 kg kg
Pier
28 12 12
14.1
87.14 m3
6.076 MT
12.15
10
12
Nos.
24.00
11 12
Cucm 2 27.36 m
0.00 54.72
8.22
13
27.36
27.36
14
27.36 m2
82.08
15
27.36
8.5
232.56
16 17
14.9 13.9
18
14.11
19 20
14.10 13.8
21
8.4
22
8.51
23
8.47
24
15.11
25
15.9
26
15.10
27 Analysis
Rate
Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall 2 and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material . Reinforced cement concrete approach 2 slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below 2 approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works Curtain wall complete as per drawing and Technical specification HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
2 12 4.00
Nos.
8.00 506.98
5.281 m3
0.3
12.00
28.80
0.15
12.00 2
4 20
14.40 40.00
Nos.
17.28 m2
17.28
60
Nos.
60.00
Nos.
4.00
206.28
206.28
256.47 m3
256.47
90.7 2
m3
90.70 54.72
27.36 m
380.134 490.875
41.52 33.00
15783.15 16198.88
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.228/1,Ch-227462
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
315.52 211.17
356.00 573.00
112,326.00 121,003.00
3/12.8
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
386.49
54.00
20,871.00
Cum Cum
8.57 80.64
6514.00 9030.00
55,851.00 728,180.00
4/12.40 Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m
8.06
73279.00
590,922.00
Item No. 1
Particulars/Descrption of items
Unit 3 Cum MT
2 Case II : With Batching plant, Transit Mixer and concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification.
Tonne
8.1
73343.00
593,419.00
Cum
33.67
10591.00
356,599.00
tonne
2.7
77554.00
208,900.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
(iv)'Providing and filling joint sealing compound as per metre drawings and technical specifications with coarse sand and 6% bitumen by weight. 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as B. M 40 grade concrete metre
36.00
17.00
612.00
46.72
4170.00
194,823.00
Item No.
Particulars/Descrption of items
Unit 3 metre
1 2 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per drawings. 20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned
4.00 15.00
13,600.00 4,470.00
Sqm
115.20
78.00
8,986.00
metre Sqm
25.50 130.56
3628.00 59.00
92,514.00 7,704.00
46.48 Sqm
614.00
28,538.00
Item No.
Particulars/Descrption of items
Unit 3 Each
1 2 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 159 b)16 mm dia re-bar fastners 25% of 159 C)20 mm dia re-bar fastners 25% of 159 d)25 mm dia re-bar fastners 25% of 159
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Unit
Qty for 2-Lane 315.52 1.61 2.77 4.67 38.00 1.28 56.69 33.35 72.81 211.17 214.29 172.20 386.49 8.57 8.57
1
Raft-
1 15.36
15.5 3.5
3.5 6.15
4 5
15.36
3.5 80.64
1.5 80.64 Total= 80.64 100 kg 8064.00 Total= kg 8064.00 8.06 Total= Tonne
13.5 Substructure(M35)2 2
0.7+1.0 2
8.442
m3
1.0 0.65
80.91
14.1 Superstructure RCC (M25)2 3.5 7.4 0.65 m3 Total= m3 33.67 33.67
33.67
10
2.00
Unit 3 3 3 3
2 11.5
12
13
14.11
11.5
0.3
m3
27.60
14
14.7
23.36
23.36
15
8.22
23.36
46.72
16
16.1
7.5
15.36
115.20
17 18
3 8.5
25.50 130.56
19
20
Nos.
40.00
20
Nos.
4.00
Unit 15 Nos.
22
2
2
0.65
0.7+1.0 2
1 1
Total-
23
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.228-1,Ch-227462
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35
Cum
1746.96
54.00
94,336.00
Cum
Cum Cum
131.07 278.80
6514.00 9030.00
853,806.00 2,517,564.00
(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
tonne
40.94
73279.00
2,999,812.00
Cum
487.22
8120.00
3,956,227.00
Cum MT
362.38
9169.00
3,322,648.00
5/13.6
Item No. 1
Particulars/Descrption of items 2 (i) TMT Corrosion Resistant reinforcement bar of Fe-500 N/mm2 Super Structure Steel (CRS)
Unit 3 Tonne
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/14.22 Strip Seal Expansion Joint (Providing and laying of a strip
seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation).
Cum
84.52
10591.00
895,152.00
MT
16.51
77554.00
1,280,417.00
metre
1640.00
0.00
metre
558.00
0.00
metre
317.00
0.00
metre
17.00
0.00
metre
24.00
11804.00
283,296.00
10/13.14 Supplying, fitting and fixing in position true to line and level
elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Cucm
105600.00
1.02
107,712.00
11/14.4 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
197.54
12993.00
2,566,638.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 12/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 13/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 14/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 15/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 16/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 17/14.9 Drainage Spouts complete as per drawing and Technical specification. 18/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 19/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
46.48 46.48
4170.00 1475.00
193,822.00 68,558.00
metre
23.24
2044.00
47,503.00
Cum Cum,
28.80 14.40
12025.00 5498.00
346,320.00 79,172.00
Each
4.00
10197.00
40,788.00
RM
69.72
160.00
11,156.00
Cum
1084.03
1524.00
1,652,065.00
Item No.
Particulars/Descrption of items
Unit 3 Each
1 2 20/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 21/8.4 Retro reflectorised Traffic sign:
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)
23/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 24/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 25/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 26/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
Each Each
17.28 60.00
5200.00 298.00
89,856.00 17,880.00
93.90 213.57
Cum
275.86
1679.00
463,169.00
Total- 27,073,301.00
Unit 2 2 16.3
31.64+15.24 2
Qty for 2Lane 563.33 200.41 102.87 142.38 71.19 146.34 94.92 425.52 1746.96
2 2
16.3 15
31.64+15.24 2
8 15.24 0.15
m3 m3 3 m
2 m/wall
16
7.7 1.2
1 4.5
m3 m3
2 3 Total R.C.C.M35
2 2 2 2
2 14
2 2 2
1.588 0.225
1.0+1.5 2
12 12 8.974 0.225 12 3
0.3 1 12 12
m3 m3 m3
1 1 2
0.2+0.45 2
13.5 Substructure PCC M20 Wing wall 13.6 Reinforcement in substuctureDirt wall 12 mm dia 2 12 mm dia 2 Abutment cap 12 12 32 mm dia 2 mm dia 2 mm dia 2
487.22 m3
487.22
2 2 6 2.6 2
86 11 12.8
kg kg kg kg kg
Abutment
11.29
Qty for 2Lane kg 2933.33 1.5 kg 17920.00 20.09 kg 2009.00 Total= kg 57244.33 Total= Tonne 57.24 84.52 m3 84.52
Unit
14.2
16.51
MT
16.51
10 13.14
50
40
6.6
Cucm 105600.00
11
8.22
23.24
46.48
12
14.7
23.24
23.24
13 14.22
12
24.00
14 14.16
23.24
m2
69.72
15
14.4
8.50
23.24
197.54
16 17
14.9 13.9
1 12 4.00
Nos.
4 1084.03
11.292 m3
18 14.11
0.3
12.00
m3
28.80
19 14.10
0.15
12.00
m3 Nos.
14.40
20
20
40
Unit 1 17.28 m
2
22
8.51
60
Nos.
60
23 15.11
213.57
214
24
15.9
275.86 m3
276
25 15.10 26 Analys
is Rate
1 2
93.9 23.24
m3 m
94 46.48
3136 19822.62
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.229/1,Ch-228087
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
286.02 201.11
356.00 573.00
101,824.00 115,234.00
2/12.1
3/12.8
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-91031999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum
coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
387.45
54.00
20,923.00
8.57 80.64
6514.00 9030.00
55,851.00 728,180.00
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Cum Pump.
8.06
73279.00
590,922.00
71.99
9169.00
660,110.00
Particulars/Descrption of items
Unit
2 3 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
7.2
73343.00
527,997.00
7/14.1
33.67
10591.00
356,599.00
8/14.2
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered sealantas complete as (iv)'Providing and filling joint sealingwith compound per per drawing and technical specification. drawings and technical specifications with coarse sand and 6% bitumen by weight. 10/14.4 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete
tonne
2.7
77554.00
208,900.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
metre
46.72
4170.00
194,823.00
12/14.11
16/8.47
17/8.51
18/16.1
Total Rate in Quantity Rs. 2 3 4 5 Construction of RCC railing of M30 Grade in-situ with 20 metre 23.36 2044.00 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification Cum a) With TATA make TMT CRS (Fe-500) grade rebar 27.60 12025.00 PCC M15 grade levelling course below approach slab Cum 27.60 5498.00 complete as per drawing and technical specification Drainage Spouts complete as per drawing and Technical Each 4.00 10197.00 specification Providing weep holes in brick mansonry/plain/reinforced Each 40.00 204.00 concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each 3500.00 b) Uni-directional Stud Each 4.00 3400.00 Providing relfective pavement marker with Micro prismatic Each 15.00 298.00 lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Sqm Removal of existing cement concrete wearing coat 115.20 78.00 including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) Particulars/Descrption of items Unit 25.50 130.56 3628.00 59.00
13,600.00 4,470.00
8,986.00
19/16.17 Replacement of Expansion Joints complete as per drawings. metre 20/16.2 Removal of existing asphaltic wearing coat comprising of Sqm 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 152
92,514.00 7,704.00
614.00
26,973.00
Each
38.10
500.00
19,049.00
Item No. 1
Particulars/Descrption of items 2 b)16 mm dia re-bar fastners 25% of 152 C)20 mm dia re-bar fastners 25% of 152 d)25 mm dia re-bar fastners 25% of 152
Unit
Qty for 2-Lane 286.02 1.61 2.77 4.67 38.00 1.28 50.35 29.62 72.81 201.11 227.85 159.60 387.45 8.57 8.57 80.64 80.64
1
Raft-
1 15.36
15.5 3.5
3.5 5.7
15.36
3.5
80.64
13.5 Substructure(M35)-
2 2
0.7+1.0 2
1
0.65
71.99
100 Kg 7199.00 Total= Kg 7199.00 Total= Tonne 7.2 0.65 m3 Total= m3 80 Total= Total= 2 Kg Kg 33.67 33.67
3.5
7.4
33.67
10 11
2 3 3 3
11 14.2 Filler joint Providing & fixing 20 mm Sl. Item thick compressible fibre board in No. No. expansion joint complete as per
drawing & Technical Specification.
11.5
11.5
14
14.7
23.36 m
23.36
15
8.22
23.36 m
46.72
16
16.1
7.5
15.36
115.20
3 8.5
8.5
metre
25.50 130.56
15.36 metre
19
13.8
20
Nos.
40.00
20
8.47
Nos.
4.00
21
8.51
15
Nos.
15.00
22
2
2
0.65
0.7+1.0 2
1 1
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.229-1,Ch-228087
Item No. 1 Particulars/Descrption of items 2 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
Cum
1836.57
54.00
99,175.00
Cum
Cum Cum
283.98 262.80
6514.00 9030.00
1,849,825.00 2,373,084.00
tonne
22.85
73279.00
1,674,257.00
Cum
565.76
8120.00
4,593,972.00
Cum MT
252.55
9169.00
2,315,642.00
Item No. 1
Particulars/Descrption of items 2 (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
Unit 3 Tonne
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/14.22 Strip Seal Expansion Joint (Providing and laying of a strip
seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation). 10/13.14 Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Cum
84.32
10591.00
893,034.00
MT
16.51
77554.00
1,280,417.00
metre
1640.00
0.00
metre
558.00
0.00
metre
317.00
0.00
metre
17.00
0.00
metre
24.00
11804.00
283,296.00
Cucm
105600.00
1.02
107,712.00
Particulars/Descrption of items 2
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
12/14.4 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications 13/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete
14/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier
Each m3
17.28 197.54
5200.00 12993.00
89,856.00 2,566,638.00
metre metre
46.48 46.48
4170.00 1475.00
193,822.00 68,558.00
15/14.7
16/14.11
16/14.10 17/14.9
consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- incharge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Drainage Spouts complete as per drawing and Technical specification.
metre
23.24
2044.00
47,503.00
Item No. 1
Particulars/Descrption of items 2 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
RM
69.72
160.00
11,156.00
19/13.9
20/13.8
Cum Each
867.84 60.00
1524.00 204.00
1,322,589.00 12,240.00
21/8.47
22/8.51
60.00
0.00 17,880.00
23/15.10
24/15.11
101.92 231.79
25/15.9
Cum
315.94
1679.00
530,464.00
Total- 25,392,005.00
5,996,341.00
10,441,881.00
7,360,981.00
1,592,802.00
Qty for 2Lane 601.47 213.07 102.87 154.53 77.27 158.82 103.02 425.52
Total = 2 12.8 PCC M-15 = 2 2 16.3 15 34.34+15. 24 2 7.5 15.24 0.15 0.15 0.15 9.55 m m m
3 3 3
Total= 3 12.8
RCC M35(open foundation)
2 m/wall 2
16 3
7.2 1.2
1 4.5 Total=
m3 m3
4 12.40 Reinforcement in foundation = 32 16 16 m/wall mm dia mm dia mm dia 2 2 2 80 160 60 8.8 8.8 16.5 100 2 32.4 Total = 5 13.5 Substructure (M35) Dirt wall =
Abutment cap =
kg kg kg kg kg
8899.95 4449.98 6257.78 3240.00 22847.70 22.85 11.43 5.40 216.90 18.82 252.55
Total = Tonne 2 2 2 2 1.588 0.225 1.0+1.5 2 9.65 12 12 12 0.2+0.45 2 0.3 1 7.23 3 Total= 6 13.5 Substructure (M20) PCC Wing wall7 13.6 Reinforcement in substuctureDirt wall = 12 12 mm dia mm dia 2 2 2 2 4.08 12.6 86 11 kg kg 1 565.76 m3 m3 m m
3 3
Abutment = M/wall
m3
565.76
1247.57 492.80
Sl. Item No. no. Abutment cap = 12 12 Abutment = 32 12 12 mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 6 2.6 2 48 48 m/wall 2 86 112 27.5 112 18.82 1.5 100 9.6 12.8
Unit
Qty for 2Lane 273.07 397.51 0.00 27185.30 2346.67 14336.00 1882.00 48160.92 48.16 84.32
kg kg kg kg kg kg
84.32 m
14.2
16.51
MT
16.51
11 13.1
50
40
6.6
Cucm
105600.00
12 8.22
23.24 m
46.48
13 14.7
23.24 m
23.24
14 14.2
12
24.00
15 14.2
23.24 m2
69.72
16 14.4
8.50
23.24 m3
197.54
17 14.9
Nos.
Sl. Item No. no. 18 13.9 Back filling behind Abutment ,Wing
wall and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material . 14.1 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification.
19
0.3
12.00
28.80
0.15
12.00
14.40
21
30
Nos.
60.00
22
30
Nos.
60.00
23
17.28 m2
17.28
231.79 m3
231.79
25 15.9
315.94 m3
315.94
26 15.10 27
Rate analysi s
1 2
101.92 m3 23.24 m
101.92 46.48
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.234/1,Ch-233214 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
228.38 112.53
356.00 573.00
81,304.00 64,478.00
3/12.8
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
198.39
54.00
10,714.00
Cum Cum
1.64 38.29
6514.00 9030.00
10,690.00 345,759.00
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35
tonne
3.83
73279.00
280,586.00
Item No. 1
Particulars/Descrption of items
Unit
2 3 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper metre plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per metre drawings and technical specifications with coarse sand and 6% bitumen by weight.
3.37
73343.00
247,423.00
32.76
10591.00
346,962.00
2.62
77554.00
203,254.00
24.00
1640.00
39,360.00
24.00
558.00
13,392.00
24.00
317.00
7,608.00
24.00
17.00
408.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
37.88 18.94
4170.00 2044.00
157,960.00 38,714.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
2.00 24.00
10197.00 204.00
20,394.00 4,896.00
4.00 12.00
13,600.00 3,576.00
Item No. 1
18/16.1
Particulars/Descrption of items 2 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
Unit 3 Sqm
metre Sqm
17.00 92.99
3628.00 59.00
61,676.00 5,487.00
Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 109 b)16 mm dia re-bar fastners 25% of 109 C)20 mm dia re-bar fastners 25% of 109 d)25 mm dia re-bar fastners 25% of 109
20/16.2
19.48 Sqm
614.00
11,964.00
Total-
Unit Qty for 2Lane 2 114.19 11 15.915 18.94 3.95 3.95 3.453 3.95 Total= Cum 2.11 4.0 m3 3 m 228.38 1.36 2.23 3.79 36.97 1.78 23.19 43.21 112.53 80.79 117.60 198.39 1.64 1.64 38.29 38.29 3829.00 3829.00 3.83 32.16 1.58 33.73 3373.50 3373.50 3.37 32.76 32.76 2620.80 2620.80 2.62 2.00 24.00 24.00 24.00 24.00 27.60
2 10.94
12.1
Earth work in or foundation of structures as per drawings & technical specification including setting out.(Upto 3m)-
10.94 3.5
3.5 4.2
Total= m3 3 12.8
PCC M15-
10.94
12.8
10.94
12.40
Reinforcement in foundation-
38.29
13.5
Substructure(M35)-
2 2
0.7+1.0 2 0.25
3.5 3.5
0.9 m3 Total= m3 100 Total= Total= 0.9 Total= 80 Total= Total= 2 12 12 12 12 0.3 Kg Kg
Tonne
13.6
Reinforcement in Substructure-
33.735
14.1
3.5
10.4
m 3 m Kg Kg
Tonne
14.2
Reinforcement in Superstructure-
32.76
10 11
14.9 14.18
Drainage Spouts complete as per drawing and Technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 2 11.5
1 2 2 2 2 4
12
14.10
11.5
0.3
14
14.7
18.94
18.94
15
8.22
18.94
37.88
16
16.1
7.5
10.94
82.05
17 18
16.17 16.2
2 8.5
17.00 92.99
19
13.8
12
Nos.
24.00
20
8.47
Nos.
4.00
21
8.51
12
Nos.
12.00
22
16.28
0.9
2
2
0.7+1.0 2
0.9
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.234-1,Ch-233214
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork.
2509.74
54.00
135,527.00
(p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
Cum Cum
215.21 246.53
6514.00 9030.00
1,401,862.00 2,226,121.00
tonne
15.94
73279.00
1,167,906.00
Cum
394.25
8120.00
3,201,310.00
Cum MT
296.40
9169.00
2,717,720.00
Item No. 1
Particulars/Descrption of items
Unit
2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
38.92
73343.00
2,854,613.00
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) MT reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)
106.40
10591.00
1,126,883.00
7.05
77554.00
546,524.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Each
17.28
5200.00
89,856.00
Item No. 1
10/14.4
Particulars/Descrption of items
Unit
2 3 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 12/Analy HAND RAIL metre sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ metre with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
14/14.11 Reinforced cement concrete approach slab including
37.88 37.88
4170.00 1475.00
157,960.00 55,873.00
18.94
2044.00
38,714.00
reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 15/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification Drainage Spouts complete as per drawing and Each Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ (B) For RCC Railing RM 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum
16/14.9
28.80 14.40
12025.00 5498.00
346,320.00 79,172.00
2.00
10197.00
20,394.00
56.82
160.00
9,092.00
453.96
1524.00
691,836.00
Item No. 1
19/13.8
Particulars/Descrption of items
Unit
2 3 Providing weep holes in brick Each mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).
20/8.47
a) Bi-directional Stud Each b) Uni-directional Stud Each 21/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
22/15.10 Curtain wall complete as per drawing and Technical
4.00 30.00
13,600.00 8,940.00
specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
72.12 164.03
Cum
358.48
1679.00
601,880.00
Total-
20,404,511.00
Unit
Qty for 2Lane 464.28 1197.504 10.80 10.21 105.931 73.845 109.350 54.675 112.388 72.900 297.864
2 2 2 2 2
2.65 4.4 0.3 0.3 24.3+10.94 2 15 24.3 24.3 24.3 24.3 9.45
7.3 12 12 11.34
m3 m3 m3 m3
12
18.79 15.70 120.79 24.62 35.31 215.21 196.92 9.00 8.21 32.40 246.53
15 2 10.94+24.3 2
11 2 2 2
m3 12 m3 10.94 m3 3 m3 Total=
m/wall
2 2
10 55 10 318 100
kg kg kg kg kg kg
7716.05 3992.59 423.82 565.33 3240.00 15937.80 Tonne 15.94 m3 m3 m3 m3 5.40 3.78 273.77 13.46 296.40
2 2 2 2
12 0.7
(0.7+1.5)
6.9
13.5
Sl. Item No. no. Wing wall7 13.6 Reinforcement in substuctureDirt wall = 12 mm dia 12 mm dia Abutment cap = 12 12 32 12 12 mm dia mm dia mm dia mm dia mm dia
Unit 1 394.25 m3
2 2 2 2 2 2 2
1.05
6 2 10 86 2 35 120 100
Abutment =
kg 25789.63 kg 1698.67 1.2 kg 8960.00 13.46 kg 1346.00 Total = kg 38921.41 Total = Tonne 38.92 106.40 m3 106.40
14.2
7.047 MT
7.05
10
14.2
12
Nos.
24.00
11
8.22
18.94 m
37.88
12
14.7
18.94 m
18.94
13
14.2
18.94 m2 8.5 m3
56.82
14
14.4
18.94
160.99
15 16
14.9 13.9
1 2 12 3.00
Nos.
2 453.96
6.305 m3
17
14.1
0.3
12.00
m3
28.80
Sl. Item No. no. 18 14.10 PCC M15 grade levelling course below 19
approach slab complete as per drawing and technical specification 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 dia AC pipe, Providing relfective pavement marker 8.51 mm with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
20
30
Nos.
30
21
8.4
17.28
17.28
22
8.47
Nos.
23
15.1
164
m3
164.025
24
15.9
358.5 m3
358.475
25 15.10 26 Analys
is Rate
1 2
72.12 m3 18.94 m
72.12 37.88
380.1336 490.875
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.235/3,Ch-234859
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
204.56 199.94
356.00 573.00
72,824.00 114,564.00
3/12.8
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete Cum pump
231.52
54.00
12,502.00
10.16 67.76
6514.00 9030.00
66,209.00 611,873.00
4/12.40 Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35
6.78
73279.00
496,539.00
Item No. 1
Particulars/Descrption of items
Unit
6/13.6
2 3 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications
4.02
73343.00
294,619.00
7/14.1
53.96
10591.00
571,448.00
8/14.2
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
tonne
4.32
77554.00
334,761.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
54.72 27.36
4170.00 2044.00
228,183.00 55,924.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
14/14.9 Drainage Spouts complete as per drawing and Each Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).
4.00 60.00
10197.00 204.00
40,788.00 12,240.00
Each Each
4.00
3500.00 3400.00
13,600.00
Item No.
Total Quantity 1 2 3 4 17/8.51 Providing relfective pavement marker with Micro Each 18.00 prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat Sqm 145.20 including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per drawings. metre 25.50 Particulars/Descrption of items Unit Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 173 b)16 mm dia re-bar fastners 25% of 173 C)20 mm dia re-bar fastners 25% of 173 d)25 mm dia re-bar fastners 25% of 173
20/16.2
78.00
11,326.00
3628.00 59.00
92,514.00 9,710.00
Sqm
164.56
27.79 Sqm
614.00
17,063.00
Total-
Unit
Qty for 2-Lane 204.56 1.86 3.25 5.47 60.89 1.62 31.71 18.66 76.47 199.94 69.12 162.40 231.52 10.16 10.16 67.76 67.76 6776.00 6776.00 6.8 25.29 14.88 1.435 41.60 4017.00 4017.00 4.02 53.96 53.96 4316.48 4316.48 4.32 4.00 36.00 36.00 36.00 36.00
Cm Cm Cm Cm Cm Cm Cm
1
Raft-
2 1 19.36
3.95 3.95
19.36 3.5
3.5 5.8
19.36
3.5
Total= m3 0.15 m3 Total= 3.5 Total= 67.76 kg Total= kg Total= Tonne 4.723 m3
4 5
19.36
1.0 100
13.5 Substructure(M35)-
2 1 2
3.5
9.4
53.956
10 11
2 3 3 3 3
2 12 12 12 12
13
11.5
0.3
27.60
14
27.36
27.36
15
27.36
54.72
16
7.5
19.36
145.20
17 18
3 8.5
25.50 164.56
19
30
Nos.
60.00
20
Nos.
4.00
Sl. No. 21
Unit 18 Nos.
22
0.8 2
2 0.7+1.0 2 19.36
0.25 4.723 1
Total-
23
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
27.79 173
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.235-3,Ch-234859
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of foundation
of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Amount (Rs.) 6
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum
2044.56
54.00
110,406.00
137.73 398.88
6514.00 9030.00
897,183.00 3,601,887.00
3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Cum Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure
26.30
73279.00
1,926,889.00
201.51
8120.00
1,636,262.00
196.10
9169.00
1,798,060.00
32.19
73343.00
2,360,580.00
Item Particulars/Descrption of items Unit No. 1 2 3 6/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete in
super-structure as per drawing and Technical Specification' including steel shuttering formwork.
Amount (Rs.) 6
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4 Retro reflectorised Traffic sign:
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular
Cum
174.28 10591.00
1,845,800.00
MT
12.15
77554.00
942,437.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
9/14.4 Providing and laying Cement concrete wearing coat M-30 m3 grade including reinforcement complete as per drawing and Technical Specifications
89,856.00 3,021,653.00
Item Particulars/Descrption of items Unit No. 1 2 3 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineerin-charge. Management shall be made for the length of the 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) metre metre
Amount (Rs.) 6
54.72 54.72
4170.00 1475.00
228,183.00 80,712.00
metre
27.36
2044.00
55,924.00
(B) For RCC Railing RM 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum 18/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
82.08
160.00
13,133.00
488.93 40.00
1524.00 204.00
745,127.00 8,160.00
Item Particulars/Descrption of items No. 1 2 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 21/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
Unit 3
Amount (Rs.) 6
4.00 60.00
13,600.00 17,880.00
92.36 210.06
Cum
153.40
1679.00 Total-
257,552.00 21,212,213.00
Unit
Qty for 2Lane 462.00 580.80 10.80 17.42 133.57 130.68 140.04 70.02 143.93 93.36 261.931 2044.56 0.00 33.95 15.70 43.56 44.52 137.73
2 2 2 2 2
m3 m3 3 m m3 m3 m3 3 m m3 m3 m3 3 m Total=
m3 m3 m3 m3 m
3
15 2
31.12+19. 36 2
0.00 348.48 9.00 9.00 32.40 398.88 13117.28 8600.00 573.51 764.44 3240.00 26295.24 26.30 4.92 3.78 118.747 2.700 53.976 11.98 196.10
2 2 2
2 2
Tonne
13.5 Substructure (M35) RCC Dirt wall = Abutment cap = Abutment = Pier Cap Pier M/wall
2 2 2 1 2
0.82 0.7
0.7+1.5 2 0.225 1 0.2+0.45 2
12 12 12 12 12 6.143
Sl. Item No. no. 6 13.5 Substructure (M20) PCC Wing wall-201.51
Unit
m3
201.51
13.6 Reinforcement in substuctureDirt wall = 12 mm dia 12 mm dia Abutment cap = 12 12 12 12 25 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia
2 2 2 2
0.95 10 1.85
6 2 13.5 86 10 1.85
26.55 kg 86 kg kg kg 13.5 86 kg kg
283.20 290.49 240.00 282.84 120.00 141.42 6215.51 728.00 2933.33 12431.02 1456.00 5866.67 1197.00 32185.48 32.19 174.28
Pier cap
Pier
2 30 2 2 2 2 27.3 30 m/wall
Abutment
14.2
6.076
MT
12.152
10
14.2
12
Nos.
36.00
11
8.22
27.36 m
54.72
12
14.7
27.36 m
27.36
13
14.2
27.36 m2
82.08
Sl. Item No. no. 14 14.4 Providing and laying Cement concrete
Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material . Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
15 16
14.9 13.9
2 2 12
2 4.00
Nos.
8 488.928
5.093 m3
17
14.1
0.3
12.00
m3
28.80
18 14.10
0.15
12.00
m3 Nos.
14.40
19
13.8
20
40
20
8.51
30
Nos.
60
21
8.4
17.28
17.28
22
8.47
Nos.
23
15.1
210.1 m3
210.06
24
15.9
153.4 m3
153.396
25 15.10 26 Analy
sis rate
1 2
92.36 m3 27.36 m
92.36 54.72
380.1336 490.875
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.237/1,Ch-236259
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
103.00 84.81
356.00 573.00
36,668.00 48,595.00
3/12.8
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
145.22
54.00
7,842.00
Cum Cum
1.19 27.79
6514.00 9030.00
7,759.00 250,944.00
4/12.40
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
Item No. 1
Particulars/Descrption of items 2 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ steel/Shyam steel
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
tonne
2.78
73279.00
203,643.00
5/13.5
Cum
25.08
9169.00
229,936.00
6/13.6
(i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 7/14.1 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
Cum
16.84
10591.00
178,300.00
8/14.2
Item No. 1
Particulars/Descrption of items 2 (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2
Unit 3 tonne
9/14.18
10/8.22
11/14.7
Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
metre metre
31.88 15.94
4170.00 2044.00
132,940.00 32,582.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
2.00 24.00
10197.00 204.00
20,394.00 4,896.00
17/8.51
4.00 12.00
13,600.00 3,576.00
Particulars/Descrption of items 2 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
Unit 3 Sqm
metre Sqm
17.00 67.49
3628.00 59.00
61,676.00 3,982.00
Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface. 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 79 b)16 mm dia re-bar fastners 25% of 79 C)20 mm dia re-bar fastners 25% of 79 d)25 mm dia re-bar fastners 25% of 79
20/16.2
Sqm
15.13
614.00
9,288.00
Total-
Unit Qty for 2Lane 2 51.50 Cm 9 13.5 15.9 3.95 3.95 4.02 Cm Cm Cm Cm Cm Cm 103.00 1.11 1.89 3.19 19.00 1.28 26.97 31.36 84.81 50.02 95.20 145.22 1.19 1.19 27.79 27.79 2779.00 2779.00 2.78 23.50 1.575 25.08 2507.00 2507.00 2.5 16.84 16.84 1346.80 1346.80 1.35 2.00 24.00 24.00 24.00 24.00
7.94
7.94 3.5
3.5 3.4
Total= m3 3 12.8 PCC M157.94 1 0.15 m3 Total= 3.5 Total= 100 kg Total= kg Total= Tonne
3 3.95 m
7.94
27.79
13.5 Substructure(M35)-
2 2
0.7+1.0 2 0.25
3.5 3.5
0.9 m3 Total= m3 100 Kg Total= Kg Total= Tonne 7.4 m3 Total= m3 80 Kg Total= Kg Total= Tonne 2 12 12 12 12 Nos. Nos. Nos. Nos. Nos.
25.07
3.5
0.65
16.835
10 11
14.9 Drainage Spouts complete as per drawing and Technical joint Providing & specification. fixing 20 mm 14.18 Filler
thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
1 2 2 2 2
Sl.N Item o. No. 12 14.10 PCC M15 grade levelling course 13 14.11
below approach slab complete as per drawing and technical Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) Replacement of Expansion Joints complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.
11.5
4 4
0.3 0.3
11.5
14
14.7
15.9 m
15.94
15
8.22
15.9 m
31.88
16
16.1
7.5
7.94
59.55
17 18
16.17 16.2
2 8.5
8.5
metre
17.00 67.49
7.94 metre
19
13.8
12
Nos.
24.00
20
8.47
Nos.
4.00
21
8.51
12
Nos.
12.00
22
16.28
0.65
2
2
0.7+1.0 2
0.65
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.237-1,Ch-236259
Item No. 1 Particulars/Descrption of items 2 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete Cum pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
1703.15
54.00
91,971.00
132.20 265.46
6514.00 9030.00
861,134.00 2,397,140.00
13.79
73279.00
1,010,744.00
99.80
8120.00
810,376.00
90.76
9169.00
832,152.00
5/13.6
Item No. 1
Total Rate in Quantity Rs. 2 3 4 5 (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne 18.77 73343.00 bar of Fe-500 N/mm2 Super Structure Particulars/Descrption of items Unit
and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
6/14.1 Furnishing
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4 Retro reflectorised Traffic sign:
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular
Cum
53.51
10591.00
566,725.00
MT
3.66
77554.00
283,615.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Each
10/14.4 Providing and laying Cement concrete wearing coat M30 grade including reinforcement complete as per drawing and Technical Specifications
m3
17.28 135.49
5200.00 12993.00
89,856.00 1,760,422.00
Item Particulars/Descrption of items No. 1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Anal HAND RAIL ysis Providing and fixing hand rail over the crash barrier Rate consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
31.88 31.88
4170.00 1475.00
132,940.00 47,023.00
metre
15.94
2044.00
32,582.00
RM
47.82
160.00
7,652.00
(A) Granular material Cum 19/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
448.03
1524.00 204.00
682,801.00 0.00
Item Particulars/Descrption of items No. 1 2 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
4.00 25.00
13,600.00 7,450.00
52.95 120.42
Cum
111.01
1679.00
186,386.00
Total- 12,250,080.00
4,360,989.00
3,019,475.00
4,131,320.00
738,296.00
Quantity Calculation fo Br. No.237/1 Ch-236259 Sl. Item No. no. 1 12.1 Earth work or
foundation of structures as per drawings & technical specification including setting out
Qty for 2Lane 0.00 245.52 10.80 7.146 57.425 53.595 80.28 40.14 82.51 53.52 220.64 851.58
m3 7.44 1 7.94 0.15 0.15 15.7 0.15 4.95 Total= 13.39 15.70 17.865 19.142 66.10 0.00 85.752 9.00 5.58 32.40 132.732
m3 7.94 0.25 0.25 1.2 12 1.5 1.5 3 0.9 12 7.44 4.5 m3 m3 m3 m3 Total=
m/wall
2 2 2
80 80 32.4
kg kg kg Total = Total =
Abutment M/wall
2 2 2 2
12 0.225
0.7+0.9 2 0.2+0.45 2
0.25 12 3.792 3
m 3 m m3
90.76
99.8 m3
99.80
Unit MT
Abutment
28 12 12
4 2 30 m/wall
95 30 95 100
kg kg kg kg kg Tonne
53.51 m3
14.2
3.657
MT
3.66
10
14.2
12
Nos.
24.00
12
8.22
15.94 m
31.88
13
14.7
15.94 m
15.94
14
14.2
15.94 m2
47.82
15
14.4
8.50
15.94 m3
135.49
16 17
14.9 13.9
2 12 4.00
Nos.
2.00 448.03
4.667 m3
18
14.1
0.3
12.00
28.80
Sl. Item No. no. 19 14.10 PCC M15 grade levelling course
below approach slab complete as per drawing and technical specification Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
20
8.51
25.00
21
8.4
17.28
17.28
22
8.47
Nos.
4.00
23
15.1
120.42 m3
120.42
24
15.9
111.01 m3
111.01
25 15.10 26 Analysi
s Rate
1 2
52.95 m3 15.94 m
52.95 31.88
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.240/1,Ch-239322
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
248.70 119.44
356.00 573.00
88,538.00 68,439.00
3/12.8
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
Cum
206.11
54.00
11,131.00
Cum Cum
5.22 34.79
6514.00 9030.00
33,994.00 314,154.00
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications tonne 3.5 73279.00 254,938.00
5/13.5
Item No. 1
Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cum
34.29
9169.00
314,386.00
6/13.6
Tonne
3.43
73343.00
251,494.00
7/14.1
Cum
26.98
10591.00
285,724.00
8/14.2
tonne
2.16
77554.00
167,381.00
9/14.18
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
Item No. 1
Particulars/Descrption of items 2 (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete Construction of RCC railing of M30 Grade insitu with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Drainage Spouts complete as per drawing and Technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
Unit 3 metre
10/8.22
11/14.7
metre metre
35.88 17.94
4170.00 2044.00
149,620.00 36,670.00
12/14.11
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
13/14.10
14/14.9 15/13.8
Each Each
2.00 24.00
10197.00 204.00
20,394.00 4,896.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per
drawings.
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
4.00 12.00
13,600.00 3,576.00
Sqm
74.55
78.00
5,815.00
metre Sqm
17.00 84.49
3628.00 59.00
61,676.00 4,985.00
20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 107 b)16 mm dia re-bar fastners 25% of 107 C)20 mm dia re-bar fastners 25% of 107 d)25 mm dia re-bar fastners 25% of 107
Sqm
20.78
614.00
12,759.00
Unit Qty for 2Lane 2 124.35 Cm 10 14.915 17.94 3.95 3.95 6.135
Cm Cm Cm Cm Cm Cm
248.70 1.24 2.09 3.59 30.45 1.62 41.20 39.26 119.44 77.31 128.80 206.11 5.22 5.22 34.79 34.79 3479.00 3479.00 3.5 32.85 1.435 34.29 3429.00 3429.00 3.4 26.98 26.978 2158.24 2158.24 2.16 2.00 24.00 24.00 24.00 24.00 27.60
2 9.94
Cm 1 Total= Cm
9.95 3.5
3.5 4.6
2.22 4.0
m3 m3
Total= m3 3 12.8 PCC M159.94 3.5 0.15 m3 Total= 1 Total= 100 kg Total= kg Total= Tonne 6.135 m3
9.94
3.5
34.79
13.5 Substructure(M35)-
2 2
0.7+1.0 2 0.25
3.15 3.5
0.82 m3 Total= m3 100 Kg Total= Kg Total= Tonne 0.82 m3 Total= m3 80 Kg Total= Kg Total= Tonne 2 12 12 12 12 0.3 Nos. Nos. Nos. Nos. Nos. m3
34.29
3.5
9.4
26.98
10 11
1 2 2 2 2 4
Sl. Item No. No. 13 14.11 Reinforced cement concrete approach slab
including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm.
11.5
0.3
14
14.7
17.94
17.94
15
17.94
35.88
16
16.1
7.5
9.94
74.55
17 16.17 18 16.2
2 8.5
17.00 84.49
19
13.8
12
Nos.
24.00
20
8.47
Nos.
4.00
21
8.51
12
Nos.
12.00
22 16.28
0.82
2
2
0.7+1.0 2
0.25 6.135 1
9.94
Total- sqm
23
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
64.3 0.6
Each
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.240-1,Ch-239322
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35
Cum
2365.72
54.00
127,750.00
Cum Cum
92.05 172.86
6514.00 9030.00
599,610.00 1,560,926.00
(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump
tonne
24.13
73279.00
1,768,101.00
Cum
434.89
8120.00
3,531,307.00
Cum
142.40
9169.00
1,305,641.00
Particulars/Descrption of items 2 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
Unit 3 MT
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure 6/14.1 Furnishing and Placing Reinforced/Prestressed cement
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
17.04
73343.00
1,249,623.00
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Cum
87.14
10591.00
922,900.00
MT
6.08
77554.00
471,219.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Particulars/Descrption of items 2
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
(V) 80cmm x 45 cm rectangular Each 10/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
17.28 152.49
5200.00 12993.00
89,856.00 1,981,303.00
B. M 40 grade concrete 12/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the in-charge. Management shall be made for 13/14.7 EngineerConstruction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
metre metre
35.88 35.88
4170.00 1475.00
149,620.00 52,923.00
metre
17.94
2044.00
36,670.00
Cum Cum,
28.80 14.40
12025.00 5498.00
346,320.00 79,172.00
Item No.
Particulars/Descrption of items
Unit 3 Each
1 2 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 19/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
RM
53.82
160.00
8,612.00
Cum Each
667.68 40.00
1524.00 204.00
1,017,545.00 8,160.00
4.00
13,600.00 0.00
73.25 166.59
Cum
181.91
1679.00
305,427.00
Total-
16,470,954.00
Unit
Qty for 2Lane 400.68 1079.50 10.80 9.31 114.817 67.095 111.06 55.53 114.145 74.04 328.754 2365.72 0.00 17.712 13.70 22.365 38.272 92.05
2 2 2 2 2
m m3 m3 3 m m3 m m3 3 m m3 m3 3 m Total =
3
12.8
m3 m3 m3 m3 m
3
m/wall
2 2 2
12 1.5 1.5 3
1 12 9.84 4.5
m3 m3 m3 Total=
2 2
11.14 13.2
46.48 2 32.4
kg kg kg kg kg
2 2 2 2
0.82 0.7
0.7+1.0 2 0.2+0.45 2
12 12 5.91 6.735
0.25 0.225 12 3
m3 m3 m3
Total=
142.40
Sl. No. 6
Unit
434.89 m3
13.6
Reinforcement in substuctureDirt wall = 12 mm dia 12 mm dia Abutment cap = 12 mm dia 12 mm dia Abutment = 32 12 12 mm dia mm dia mm dia m/wall
2 2
0.95 2 2 2 2 33 100
6 2 10 1.85 80 33 80 13.13
kg kg kg kg
283.20 290.49 240.00 282.84 8333.59 1601.60 4693.33 1313.00 17038.06 17.04 87.14
6.076
MT
6.076
10
12
Nos.
24.00
12
17.94
35.88
13
17.94
17.94
14
17.94
53.82
15
8.50
17.94
152.49
16
Nos.
Sl. No. 17
Unit
12
4.00
6.955
18
14.11
0.3
4.00
12
28.80
19
14.10
0.15
4.00
12
m3 Nos.
14.40
20
13.8
40
40
21
8.47
Nos.
22
8.4
17.28
17.28
23
15.11
166.59 m3
166.59
24
15.9
181.91 m3
181.91
25
15.10
1 2
73.25 17.94
m3 m
73.25 35.88
RPM
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing br No.245/3,Ch-244803 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per specification, including setting shoring and bracing, removal deleterious matter, dressing of backfilling with approved material. drawing and technical out, construction of of stumps and other sides and bottom and
Unit 3
Total Quantit 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
100.74 112.53
356.00 573.00
35,864.00 64,478.00
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 4/12.40 Reinforcement in Foundation: Supplying,
fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
Cum
197.22
54.00
10,650.00
Cum Cum
1.64 38.29
6514.00 9030.00
10,690.00 345,759.00
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure 5/13.5 Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications
3.83
73279.00
280,586.00
Item No. 1
Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35
Unit 3
Total Quantit 4
Rate in Rs. 5
Amount (Rs.) 6
a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. tonne
22.12
9169.00
202,822.00
2.21
73343.00
162,235.00
32.76
10591.00
346,962.00
2.62
77554.00
203,254.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
Total Quantit 4
Rate in Rs. 5
Amount (Rs.) 6
B. M 40 grade concrete metre 11/14.7 Construction of RCC railing of M30 Grade in-situ metre with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade Cum rebar 13/14.10 PCC M15 grade levelling course below approach Cum slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Each Technical specification 15/13.8 Providing weep holes in brick Each mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud
37.88 18.94
4170.00 2044.00
157,960.00 38,714.00
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
2.00 20.00
10197.00 204.00
20,394.00 4,080.00
Each Each
4.00
3500.00 3400.00
13,600.00
Item No.
Particulars/Descrption of items
Unit 3 Each
1 2 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.
Sqm
82.05
78.00
6,400.00
19/16.17 Replacement of Expansion Joints complete as per metre 20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 97 b)16 mm dia re-bar fastners 25% of 97 C)20 mm dia re-bar fastners 25% of 97 d)25 mm dia re-bar fastners 25% of 97 Sqm
17.00 92.99
3628.00 59.00
61,676.00 5,487.00
Sqm
16.17
614.00
9,926.00
Total-
Unit
Qty for 2-Lane 100.74 1.36 2.23 3.79 36.97 1.78 23.19 43.21 112.53 71.22 126.00 197.22 1.64 1.64 38.29 38.29
Cm Cm Cm Cm Cm Cm Cm
10.94
10.94 3.5
3.5 4.5
12.8
PCC M15-
10.94
10.94
38.29
100 kg 3829.00 Total= kg 3829.00 Total= Tonne 3.83 3.453 m3 20.55 1.575 22.12
13.5 Substructure(M35)-
2 2
0.7+1.0 2 0.25
3.5 3.5
0.9 m3 Total= m3
22.12
100 Kg 2212.00 Total= Kg 2212.00 Total= Tonne 2.21 0.9 m3 Total= m3 32.76 32.76
3.5
10.4
32.76
80 Kg 2620.80 Total= Kg 2620.80 Tonne Total= 2.62 2 12 12 12 12 0.3 Nos. Nos. Nos. Nos. Nos. 3 m 2.00 24.00 24.00 24.00 24.00 27.60
10 11
1 2 2 2 2 4
Unit
2 11.5
0.3
m3
14
14.7
18.94
18.94
15
8.22
18.94
37.88
16
16.1
7.5
10.94
82.05
2 8.5
17.00 92.99
19
13.8
10
Nos.
20.00
20
8.47
Nos.
4.00
21
12
Nos.
12.00
22
0.9
2
2
0.7+1.0 2
0.9
Total- sqm
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No.245/3,Ch-244803
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of foundation
of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
1772.80
54.00
95,732.00
Cum Cum
94.95 173.95
6514.00 9030.00
618,487.00 1,570,733.00
3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in MT substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
17.51
73279.00
1,283,456.00
121.04
8120.00
982,845.00
96.28
9169.00
882,803.00
Item No. 1
Particulars/Descrption of items
Unit
2 3 (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure
in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement MT bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate metre in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular
106.40 10591.00
1,126,883.00
7.05
77554.00
546,524.00
24.00
1640.00
39,360.00
24.00
558.00
13,392.00
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
9/14.4
Providing and laying Cement concrete wearing coat M- m3 30 grade including reinforcement complete as per drawing and Technical Specifications
89,856.00 2,091,744.00
Item No.
Particulars/Descrption of items
Unit 3
Amount (Rs.) 6
1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification.
metre metre
37.88 37.88
4170.00 1475.00
157,960.00 55,873.00
metre
18.94
2044.00
38,714.00
RM
56.82
160.00
9,092.00
(A) Granular material Cum 18/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
477.60 40.00
1524.00 204.00
727,863.00 8,160.00
Item No.
Particulars/Descrption of items
Unit
Amount (Rs.) 6
1 2 3 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 20/8.51 Providing relfective pavement marker with Micro prismatic Each lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
21/15.10 Curtain wall complete as per drawing and Technical
4.00 30.00
13,600.00 8,940.00
specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
63.75 144.99
Cum
112.28
1679.00 Total-
188,519.00 13,069,892.00
m 3 m 3 m 3 m m3 m3 m3 m3 3 m 3 m 3 m Total =
0.00 251.81 808.044 10.80 7.51 76.88 73.85 96.66 48.33 99.35 64.44 235.14 1772.80 0.00 18.79 15.70 35.84 24.62 94.95 0.00 124.72 9.00 7.83 32.40 173.946
12.8
m m3 m3 m3 Total= m3
12.8
m/wall
2 2 2
12 0.25 0.25 3
m3 m3 m3
2 2
13.5
Abutment = M/wall 6 7 13.5 13.6 Substructure (M20) PCC Wing wallReinforcement in substucture-
2 2 2 2
0.9 0.7
0.7+0.95 2 0.2+0.45 2
12 12 3.85 3
m3 3 m m3 m3
m3
121.04
Sl. No. 7
Item no. Dirt wall = 12 12 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 2 6 0.78 10 1.85 2 2 27 m/wall 26.12 2 13.5 86 93 26.5 120 100 86
Unit Qty for 2Lane Kg Kg Kg Kg 6.125 Kg 27 Kg 1.2 Kg 10.87 Kg Total = Kg Total = Tonne 106.40 m3 278.61 238.51 240.00 282.84 8790.51 1272.00 6912.00 1087.00 19101.47 19.10 106.40
Abutment cap =
Abutment =
14.1
14.2
10
14.18
11
8.22
12
14.7
13
14.16
14
14.4
15 16
14.9 13.9
17
14.11
18
14.10
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. (A) Granular material . Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
7.047
MT
7.05
12
Nos.
24.00
18.94
37.88
18.94
18.94
18.94
m2
56.82
8.50
18.94
160.99
1 2 12 4.98
2 4
Nos. m3
2.00 477.60
0.3
12.00
m3
28.80
0.15
12.00
m3
14.40
Sl. No. 19
Item no.
Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. 8.4 Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 15.11 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond 15.9 Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. 15.10 Curtain wall complete as per drawing and Technical specification Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
13.8
20
Nos.
30.00
21
Nos.
4.00
22
17.28
17.28
23
144.99
m3
144.99
24
112.28
m3
112.28
25 26
1 2
63.75 18.94
m3 m
63.75 37.88
380.1336 490.875
11.89 10.00
4519.789 4908.75
380.1336 490.875
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali bypass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no - 250/4, Ch-249990
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
98.16 136.11
356.00 573.00
34,945.00 77,993.00
3/12.8
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
291.42
54.00
15,737.00
Cum Cum
6.15 57.44
6514.00 9030.00
40,087.00 518,639.00
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications tonne 5.74 73279.00 420,915.00
5/13.5
Item No. 1
Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cum
23.87
9169.00
218,903.00
6/13.6
7/14.1
8/14.2
(i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel tonne
2.4
73343.00
175,070.00
32.76
10591.00
346,962.00
(i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
2.62
77554.00
203,254.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
37.88 18.94
4170.00 2044.00
157,960.00 38,714.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
2.00 30.00
10197.00 204.00
20,394.00 6,120.00
Each Each
4.00
3500.00 3400.00
13,600.00
Item No.
Particulars/Descrption of items
Unit 3 Each
1 2 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per
drawings.
Sqm
82.05
78.00
6,400.00
metre Sqm
17.00 92.99
3628.00 59.00
61,676.00 5,487.00
20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 106 b)16 mm dia re-bar fastners 25% of 106 C)20 mm dia re-bar fastners 25% of 106 d)25 mm dia re-bar fastners 25% of 106
Sqm
32.60
614.00
20,017.00
Cm Cm Cm Cm Cm Cm
1.36 2.23 3.79 36.97 1.78 25.17 64.82 136.11 84.53 206.89 291.42 6.15 6.15 57.44 57.44
11.5 3.5
3.5 7.389
10.94
3.5
57.44
13.5 Substructure(M35)-
2 2
0.7+1.5 2
3.5 0.25
0.90
3.5 m3 Total= m3
23.87
100 Kg 2387.00 Total= Kg 2387.00 Total= Tonne 2.4 0.9 m3 Total= m3 32.76 32.76
3.5
10.4
32.76
80 Kg 2620.80 Total= Kg 2620.80 Total= Tonne 2.62 2 12 12 12 12 0.3 Nos. Nos. Nos. Nos. Nos. m3 2.00 24.00 24.00 24.00 24.00 27.60
10 14.9 Drainage Spouts complete as per drawing and Technical joint Providing & fixing 20 11 14.18 Filler
mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to
1 2 2 2 2
2 11.5
12
13
11.5
0.3
m3
27.60
14
18.94 m
18.94
15
18.94 m
37.88
16
16.1
7.5
10.94
82.05
17 16.17 18 16.2
2 8.5
17.00 92.99
19
13.8
15
Nos.
30.00
20
8.47
Nos.
4.00
21
8.51
10
Nos.
10.00
22 16.28
2
2
0.9
0.7+1.5 2
0.25 2.9
sqm sqm
1.5 0.9
23
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No-250/4, Ch-249990
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35
Cum
859.13
54.00
46,394.00
Cum Cum
86.19 245.78
6514.00 9030.00
561,467.00 2,219,349.00
(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
tonne
25.21
73279.00 1,847,449.00
Cum
195.77
8120.00
1,589,653.00
Cum MT
91.37
9169.00
837,728.00
5/13.6
Item No. 1
Particulars/Descrption of items 2 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Tonne
20.99
73343.00 1,539,567.00
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular
Cum
106.40
10591.00 1,126,883.00
MT
7.05
77554.00
546,524.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
17.28
5200.00
89,856.00
Item No.
Particulars/Descrption of items
Unit
Rate in Rs.
Amount (Rs.)
1 2 3 10/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications. 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. metre metre
5 6 12993.00 2,091,744.00
37.88 37.88
4170.00 1475.00
157,960.00 55,873.00
metre
18.94
2044.00
38,714.00
Cum Cum,
28.80 14.40
12025.00 5498.00
346,320.00 79,172.00
Each
4.00
10197.00
40,788.00
RM
56.82
160.00
9,092.00
Item No. 1
Particulars/Descrption of items
2 (A) Granular material 19/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
21/8.51
4.00
13,600.00 0.00
22/15.10
23/15.11
66.07 150.26
24/15.9
Cum
158.41
1679.00
265,971.00
Total- 15,047,507.00
Quantity Calculation fo Br. No.250/4, Ch-249990 Sl. Item no. No. 1 12.1
Earth work or foundation of structures as per drawings & technical specification including setting out.
Unit
2 2 2
m3 3 m m3 m3 m3 m3 m3 3 m Total =
414.84 8.21 8.63 150.26 41.83 65.64 102.95 66.78 859.13 0.00 19.69 24.62 28.19 13.70 86.19 0.00 196.92 9.00 7.46 32.40 245.78
15 22.26 22.26
12.8
10.94 15 5.66 1
m3 m3 m3 m3 Total= m3
12.8
m/wall
2 2 2
m3 m3 m3 m3
12.40
2 2
120 104
13.5
Abutment M/wall
2 2 2 2
0.9 0.7
0.7+1.5 2 0.2+0.45 2
12 12 12 5.985
13.5
195.77 m3
195.77
Unit
13.6
Reinforcement in substuctureDirt wall 12 mm dia 12 mm dia Abutment cap 12 12 32 12 12 mm dia mm dia mm dia mm dia mm dia
2 2 2 2 2 2 2
86
kg kg kg kg
283.20 238.51 240.00 282.84 13906.17 873.60 4000.00 1167.00 20991.32 20.99 106.40
Abutment
14.1
14.2
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification.
5.5
7.047 MT
7.047
10
14.18
12
Nos.
24.00
12
8.22
18.94 m
37.88
13
14.7
18.94 m
18.94
14
14.16
18.94 m2
56.82
15
14.4
8.5
18.94 m3
160.99
16
14.9
Nos.
Unit
13.9
12
4.00
5.385 m3
18
0.3
4.00
12
28.80
19
0.15
4.00
12
14.40
20
Nos.
30
21
Nos.
4.00
22
17.28
17.28
23
150.26 m3
150.26
24
158.41 m3
158.41
25 26
1 2
66.07 m3 18.94 m
66.07 37.88
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no 251/1 , Ch-250350
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
60.12 126.12
356.00 573.00
21,403.00 72,265.00
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 4/12.40 Reinforcement in Foundation: Supplying, fitting and
placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
Cum
316.51
54.00
17,092.00
Cum Cum
8.57 80.64
6514.00 9030.00
55,851.00 728,180.00
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications
tonne
8.06
73279.00
590,922.00
2 3 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Cum
Item No. 1
Particulars/Descrption of items
Unit
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
25.22
9169.00
231,207.00
2.5
73343.00
184,898.00
33.67
10591.00
356,599.00
tonne
2.69
77554.00
208,900.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
Item Particulars/Descrption of items No. 1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.1 Reinforced cement concrete approach slab 1 including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.1 PCC M15 grade levelling course below approach 0 slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
46.72 23.36
4170.00 2044.00
194,823.00 47,748.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
4.00 30.00
10197.00 204.00
40,788.00 6,120.00
Each Each
4.00
3500.00 3400.00
13,600.00
Item Particulars/Descrption of items No. 1 2 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.1 Replacement of Expansion Joints complete as per drawings. 7 20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.2 (A)'Supplying and applying Epoxy based bonding 8 agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.5 Providing, placing and fixing in position Chemical 3 rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 139 b)16 mm dia re-bar fastners 25% of 139 C)20 mm dia re-bar fastners 25% of 139 d)25 mm dia re-bar fastners 25% of 139
Unit 3 Each
Sqm
115.20
78.00
8,986.00
metre Sqm
25.50 130.56
3628.00 59.00
92,514.00 7,704.00
Sqm
29.64
614.00
18,199.00
Total-
Unit Qty for 2Lane 2 30.06 13 19.785 23.36 3.95 3.95 3.95 3.95 1 Total= 2.66 4.0 Cm Cm Cm Cm Cm Cm Cm Cm Cm Cm 3 m 3 m 60.12 1.61 2.77 4.67 38.00 1.28 17.11
0.9 0.175 0.2 7.4 0.65 2.548 2.548 3.95 3.5 6.15
1
Raft-
15.66
3.65
15.36
3.5
80.64
100 kg 8064.00 Total= kg 8064.00 Total= Tonne 8.06 0.00 3 15.16 m 2.548 2.548 0.25 Total= 100 Total= Total= 0.65 Total= 80 Total= Total= 2 12 12 12 12 8.918 1.138 25.22 2521.00 2521.00 Tonne 2.5 33.67 m3 33.67 m3 Kg 2693.60 Kg 2693.60 Tonne 2.69 Nos. 4.00 Nos. Nos. Nos. Nos. 36.00 36.00 36.00 36.00 m3 m3 m3 Kg Kg
8 9
3.5
7.4
2 33.67
10 11
2 3 3 3 3
11.5
0.3
13
11.5
0.3
27.60
14
23.36
23.36
15
23.36
46.72
16
7.5
15.36
115.20
17 18
3 8.5
25.50 130.56
19
15
Nos.
30.00
20
Nos.
4.00
21
15
Nos.
15.00
22
2
2
0.65
0.7+1.0 2
1 0.65
Unit Qty for 2Lane Total- sqm 29.64 83.558 Each 139 0.6
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No : 251/1, Ch-250350
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35
Cum
1007.22
54.00
54,391.00
Cum
118.91 236.87
6514.00 9030.00
774,551.00 2,138,891.00
(II) Using Batching plant Transit mixer and concrete Cum pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications Cum MT
33.33
73279.00
2,442,574.00
74.80
8120.00
607,376.00
93.64
9169.00
858,552.00
Item No. 1
Particulars/Descrption of items
Unit
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure
and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
21.50
73343.00
1,577,210.00
6/14.1 Furnishing
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4 Retro reflectorised Traffic sign:
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (V) 80cmm x 45 cm rectangular
Cum
107.02
10591.00
1,133,449.00
MT
7.31
77554.00
567,230.00
metre metre
36.00 36.00
1640.00 558.00
59,040.00 20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
10/14.4 Providing and laying Cement concrete wearing coat M30 grade including reinforcement complete as per drawing and Technical Specifications.
m3
17.28 198.56
5200.00 12993.00
89,856.00 2,579,891.00
Item No.
Particulars/Descrption of items
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analys HAND RAIL is Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
16/14.9 Drainage
metre metre
46.72 46.72
4170.00 1475.00
194,823.00 68,912.00
metre
23.36
2044.00
47,748.00
Cum Cum,
Spouts complete as per drawing and Each Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing
18/13.9 Back filling behind Abutment ,Wing wall and Return
70.08
160.00
11,213.00
393.41
1524.00
599,554.00
Item No. 1
Particulars/Descrption of items 2 concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
Unit 3 Each
20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 21/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) Cum Cum B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick Cum comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring Cum at cross drainage works for relatively less important works 4.00
67.85 154.31
168.17
1679.00
282,358.00
Total- 15,314,994.00
Unit
Qty for 2Lane 0.00 490.29 11.52 8.63 154.31 64.50 103.68 105.73 68.58 1007.22
2 2
m m3 m3 m3 m3 m3 3 m 3 m Total =
12.8 PCC M-15 = 12 15.36 2 22.86+15.362 c/wall 15.36 15 3.75 1 0.15 0.15 0.15 13.7 Total= m 3 m m3
3
12.8
m/wall
2 2 2
1 1.5 1.5 3
m3 m3 m3 m3
2 2
80 104
54.72 2
kg kg kg kg
2 2 2 1 1 2
0.65 0.7
0.7+1.0 2 0.225 1 0.2+0.45 2
m 3 m m3 m3 3 m 3 m
13.5
74.8 m3
74.80
26.55
kg
283.20
Sl. No. 12 Abutment cap = 12 12 Pier cap= 12 12 25 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 2 2 2 2 2 2 0.78 10 1.85 10 1.85 100 27.3 16 100 27.3 16 2 13.6 86.00 13.60 86.00 4.65 16 100 4.65 16 100 100 2 1.2 86.00
Unit kg kg kg kg kg kg kg kg
Qty for 2Lane 238.51 241.78 282.84 241.78 282.84 7175.93 776.53 3413.33
Abutment =
Pier=
m/wall
kg 3587.96 kg 776.53 1.2 kg 3413.33 7.9 kg 790.00 Total = kg 21504.57 Total = Tonne 21.50 53.51 107.02 m3
3.657
MT
7.31
10
12
Nos.
36.00
11
23.36
46.72
12
23.36
23.36
13
23.36
70.08
14
8.50
23.36
m3
198.56
Sl. No. 15
Nos.
16
12
4.00
4.098
m3
393.41
17
0.3
4.00
12
28.80
18
0.15
4.00
12
m3
14.40
19
40
Nos.
40.00
20
Nos.
4.00
21
17.28
17.28
22
154.31 m3
154.31
23
168.17 m3
168.17
24
67.85
m m
67.85
drawing and Technical specification. 25 Analysi HAND RAIL s rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
23.36
46.72
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no- 252/1,Ch-251630
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
60.24 96.27
356.00 573.00
21,446.00 55,165.00
3/12.8
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and Cum concrete pump
172.60
54.00
9,321.00
5.61 52.19
6514.00 9030.00
36,521.00 471,231.00
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications
5.22
73279.00
382,407.00
Item No. 1
Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
6/13.6
7/14.1
a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer Cum and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999.
17.41
9169.00
159,640.00
1.7
73343.00
126,591.00
B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Cum
26.98
10591.00
285,724.00
tonne
2.16
77554.00
167,381.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
B. M 40 grade concrete metre 11/14.7 Construction of RCC railing of M30 Grade in- metre situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). Cum Cum
35.88 17.94
4170.00 2044.00
149,620.00 36,670.00
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
2.00 30.00
10197.00 204.00
20,394.00 6,120.00
Item No. 1
Particulars/Descrption of items
2 a) Bi-directional Stud b) Uni-directional Stud 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per
drawings.
Sqm
74.55
78.00
5,815.00
metre Sqm
17.00 84.49
3628.00 59.00
61,676.00 4,985.00
20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface. 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 94 b)16 mm dia re-bar fastners 25% of 94 C)20 mm dia re-bar fastners 25% of 94 d)25 mm dia re-bar fastners 25% of 94
Sqm
22.62
614.00
13,891.00
Total-
Unit Qty for 2Lane 30.12 10 14.915 17.94 3.95 3.95 3.95 1 Total= 1.85 4.0 Total= Cm Cm Cm Cm Cm Cm Cm Cm Cm m m3 m3 m3
3
60.24 1.24 2.09 3.59 30.45 1.62 18.03 39.26 96.27 74.46 98.14 172.60 5.61 5.61 52.19 52.19
9.94
11.5 3.5
3.5 3.505
10.24
3.65
9.94
3.5
52.185
100 kg 5218.50 Total= kg 5218.50 Total= Tonne 5.2 0.00 15.98 1.4 17.41
m3 m3
17.26
3.5
9.4
26.978 26.978
26.978
10
Sl. Item No. No. 11 14.18 Filler joint Providing & fixing 20 mm thick
compressible fibre board in expansion joint complete as per drawing & Technical Specification.
11.5
2 2 2 2 4
12 12 12 12 0.3
Unit Qty for 2Lane Nos. 24.00 Nos. 24.00 Nos. 24.00 Nos. 24.00 27.60 m3 m3 27.60
13 14.11
11.5
0.3
14
14.7
17.94
17.94
15
8.22
17.94
35.88
16
16.1
7.5
9.94
74.55
2 8.5
17.00 84.49
18
19
15
Nos.
30.00
20
Nos.
4.00
21
10
Nos.
10.00
0.82
2
2
0.7+1.0 2
1 0.82
Sl. Item No. No. 23 16.53 Providing, placing and fixing in position
Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
56.46 0.6
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br no : 252/1 ,Ch-251630
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35
Cum
627.34
54.00
33,877.00
Cum Cum
53.77 167.76
6514.00 9030.00
350,252.00 1,514,873.00
(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
tonne
17.02
73279.00
1,247,001.00
Cum
74.95
8120.00
608,594.00
Cum MT
66.89
9169.00
613,303.00
5/13.6
Item No. 1
Particulars/Descrption of items 2 (i) TMT Corrosion Resistant reinforcement bar of Fe-500 N/mm2 Super Structure Steel (CRS)
Unit 3 Tonne
6/14.1
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) MT reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper metre plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per metre drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications. 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
87.14
10591.00
922,900.00
6.08
77554.00
471,219.00
24.00
1640.00
39,360.00
24.00
558.00
13,392.00
24.00
317.00
7,608.00
24.00
17.00
408.00
152.49
12993.00
1,981,303.00
Particulars/Descrption of items 2 B. M 40 grade concrete HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Drainage Spouts complete as per drawing and Technical specification. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
12/14.7
metre
17.94
2044.00
36,670.00
13/14.11
RM
53.82
160.00
8,612.00
17/13.9
18/13.8
Cum Each
336.48 20.00
1524.00 204.00
512,796.00 4,080.00
Item No.
Particulars/Descrption of items
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
1 2 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
20/8.51
4.00
13,600.00 0.00
21/15.10
22/15.11
51.76 117.72
23/15.9
Cum
113.29
1679.00
190,214.00
Total- 10,722,558.00
Unit
Qty for 2Lane 0.00 172.96 7.46 9.00 117.72 67.10 120.13 80.66 52.32 627.34 0.00 16.28 15.12 22.37 0.00 53.77 0.00
2 2
15 2
17.44+9.94 2
m m3 3 m m3 m3 3 m m m3 Total = m3 m3 m3 m3
3
17.44 17.44
15
m/wall
2 2 2
12 0.25 0.25 3
m3 m3 3 m m3
2 2
100 80
12.94 15 100
9984.57 3792.59 3240.00 17017.16 17.02 4.92 3.78 50.18 8.00 66.89
Abutment = M/wall
2 2 2 2
0.82 0.7
0.7+1.0 2 0.2+0.45 2
0.25 12 2.46 3
13.5
74.95 m3
74.95
2 2
6 0.95
26.55 2
86
kg kg
283.20 290.49
Unit
Abutment cap =
12 12 25 12 12
2 2 2 2 2
10 1.85 2 17 17
Abutment =
m/wall
6.076 MT
6.08
12
Nos.
24.00
12
8.22
17.94 m
35.88
13
14.7
17.94 m
17.94
14 14.16
17.94 m2
53.82
15
14.4
8.50
17.94 m3
152.49
16 17
14.9
1 2 12 4.00
Nos.
2.00 336.48
3.505 m3
18
0.3
4.00
12
28.80
Sl. Item No. no. 19 14.10 PCC M15 grade levelling course below
approach slab complete as per drawing and technical specification
Unit
0.15
4.00
12
20
20
Nos.
20.00
22
Nos.
4.00
117.72 m3
117.72
24
15.9
113.29 m3
113.29
25 15.10 26 Analys
is rate
1 2
51.76 m3 17.94 m
51.76 35.88
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no- 255/1,Ch-254000 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
68.22 99.39
356.00 573.00
24,287.00 56,954.00
2/12.1
3/12.8
I.Ordinary Soil B.Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
Cum
184.42
54.00
9,959.00
Cum Cum
5.61 52.185
6514.00 9030.00
36,521.00 471,231.00
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 5.22 73279.00 382,407.00
5/13.5
Item No. 1
Particulars/Descrption of items 2 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cum
20.18
9169.00
185,008.00
6/13.6
7/14.1
(i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump Cum
2.00
73343.00
146,907.00
ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
26.98
10591.00
285,724.00
tonne
2.16
77554.00
167,381.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Item No.
Particulars/Descrption of items
Unit
1 2 3 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 11/14.7 Construction of RCC railing of M30 Grade in-situ metre with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Each Each
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
35.88 17.94
4170.00 2044.00
149,620.00 36,670.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
2.00 30.00
10197.00 204.00
20,394.00 6,120.00
4.00
3500.00 3400.00
13,600.00
Item No.
Particulars/Descrption of items
Unit
1 2 3 17/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing Sqm coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per metre
drawings.
74.55
78.00
5,815.00
17.00 84.49
3628.00 59.00
61,676.00 4,985.00
20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 99 b)16 mm dia re-bar fastners 25% of 99 C)20 mm dia re-bar fastners 25% of 99 d)25 mm dia re-bar fastners 25% of 99
Sqm
Sqm
23.41
614.00
14,376.00
Total-
Unit Qty for 2Lane 2 34.11 10 14.915 17.94 3.95 3.95 3.95 1 Total= 2.16 4.0 Total= 0.15 Total= 1.5 Total= Cm Cm Cm Cm Cm Cm Cm Cm Cm 3 m m3 m3 m3 68.22 1.24 2.09 3.59 30.45 1.62 21.15 39.26 99.39 75.22 109.20 184.42 5.61 5.61 52.185 52.185 5218.50 5218.50 5.22 18.74 1.4 20.18 2003.00 2003.00 2.0 26.978 26.978 2158.24 2158.24 2.16 2.00 24.00 24.00 24.00 24.00 27.60
3 4
10.24 9.94
3.65 3.5
52.185
100 kg Total= kg Total= Tonne 3.5 0.82 m3 Total= m3 100 Kg Kg Total= Total= Tonne 0.82 m3 Total= m3 80 Kg Kg Total= Total= Tonne 2 Nos. 12 12 12 12 0.3 Nos. Nos. Nos. Nos. m3
13.5 Substructure(M35)-
2 2
0.7+1.0 2 0.25
8 9
3.5
9.4 26.978
10 11
1 2 2 2 2 4
12
11.5
11.5
0.3
14
17.94
17.94
15
17.94
35.88
16
7.5
9.94
74.55
17 18
2 8.5
8.5 9.94
metre metre
17.00 84.49
19
15
Nos.
30.00
20
Nos.
4.00
21
10
Nos.
10.00
22
0.82
2
2
0.7+1.0 2
1 0.82
59.616 0.6
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br No : 255/1, Ch-254000 m
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35
Cum
728.38
54.00
39,333.00
Cum
56.37 167.76
6514.00 9030.00
367,181.00 1,514,873.00
3/12.40
4/13.5
(II) Using Batching plant Transit mixer and concrete Cum pump Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications Cum
19.01
73279.00
1,393,333.00
412.69
8120.00
3,351,043.00
Cum MT
81.24
9169.00
744,890.00
5/13.6
Item No. 1
Particulars/Descrption of items
Unit
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
14.52
73343.00
1,065,279.00
6/14.1
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)
Cum
87.14
10591.00
922,900.00
7/14.2
MT
6.08
77554.00
471,219.00
8/14.18
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
9/8.4
17.28
5200.00
89,856.00
Particulars/Descrption of items
Unit
11/8.22
2 3 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications. Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
B. M 40 grade concrete metre 12/Analysi HAND RAIL metre s Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- incharge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ metre with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
35.88 35.88
4170.00 1475.00
149,620.00 52,923.00
17.94
2044.00
36,670.00
14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 15/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Each Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing RM 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum
53.82
160.00
8,612.00
381.12
1524.00
580,827.00
Particulars/Descrption of items
Unit
20/8.47
2 3 Providing weep holes in brick Each mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). Each Each Each
a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
4.00
13,600.00 0.00
54.67 124.34
Cum
121.20
1679.00
203,495.00
Total- 14,071,614.00
Item no.
2 2
18 2
18.42+9.94 2
Qty for 2Lane 0.00 312.51 7.46 9.00 124.34 80.51 54.11 85.19 55.26 728.381 0.00 16.28 17.72 22.365 56.37 0.00 119.28 9.00 7.08 32.40 167.76
18.42 18.42
Total= 3 12.8
RCC M35(open foundation)
m/wall
2 2
120 80
12.94 15 100
Abutment = M/wall
2 2 2 2
0.82 0.7
0.7+1.0 2
0.2+0.45 2
0.25 12 2.925 3
m3 m3 3 m
13.5
412.69 m3
412.69
2 2
6 0.95
26.55 2
86
kg kg
283.20 290.49
Sl.No.
Item no.
Unit Abutment cap = 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 10 1.85 2 20 100 m/wall 13.5 86 100 27.3 20 100 5.25 kg kg
Abutment =
kg 8101.85 kg 970.67 1 kg 3555.56 8 kg 800.00 Total = kg 14524.61 Total = Tonne 14.52 87.14 m
3
87.14
6.076
MT
6.08
10
12
Nos.
24.00
11
17.94
35.88
12
17.94
17.94
13
17.94
m2
53.82
14
8.50
17.94
152.49
15 16
1 2 12 4.00
2 3.97
Nos. m
3
2 381.12
17
0.3
4.00
12
28.80
Sl.No.
Item no.
18
19
Nos.
40
20
Nos.
21
8.4
Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3
17.28
17.28
22
124.335 m3
124.34
23
121.20 m3
121.20
24
1 2
54.67 17.94
m3 m
54.67 35.88
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-255/2, Ch-254750
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
52.66 134.75
356.00 573.00
18,747.00 77,213.00
2/12.1
3/12.8
(i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete Cum pump
324.10
54.00
17,502.00
8.57 53.76
6514.00 9030.00
55,851.00 485,453.00
4/12.40
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications
5.38
73279.00
393,948.00
Item No. 1
Particulars/Descrption of items
Unit
6/13.6
2 3 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
23.95
9169.00
219,596.00
Tonne
2.40
73343.00
175,657.00
7/14.1
Cum
33.67
10591.00
356,599.00
8/14.2
tonne
2.69
77554.00
208,900.00
9/14.18
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
Particulars/Descrption of items
Unit 3
2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
46.72 23.36
4170.00 2044.00
194,823.00 47,748.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
4.00 30.00
10197.00 204.00
40,788.00 6,120.00
Each Each
4.00
3500.00 3400.00
13,600.00
Particulars/Descrption of items
Unit
2 3 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing Sqm coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per metre
drawings.
115.20
78.00
8,986.00
25.50 130.56
3628.00 59.00
92,514.00 7,704.00
20/16.2
Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.
Sqm
21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface. 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 139 b)16 mm dia re-bar fastners 25% of 139 C)20 mm dia re-bar fastners 25% of 139 d)25 mm dia re-bar fastners 25% of 139
Sqm
59.53
614.00
36,554.00
Total-
95,960.00
952,754.00
395,253.00
1,689,338.00
Unit Qty for 2Lane 26.33 13 19.785 23.36 3.95 3.95 3.95 Cm Cm Cm Cm Cm Cm Cm 52.66 1.61 2.77 4.67 38.00 1.28 16.21 9.54 60.67 134.75 151.90 172.20 324.10 8.57 8.57 53.76 53.76
2 2 1
15.5 3.5
3.5 6.15
15.36
3.5
53.76
100 kg 5376.00 Total= kg 5376.00 Total= Tonne 5.4 2.414 2.41 m3 0.25 Total= m3 14.36 8.45 1.14 23.95
13.5 Substructure(M35)-
2 2
23.95
100 Kg 2395.00 Total= Kg 2395.00 Total= Tonne 2.4 0.65 m3 Total= m3 33.67 33.67
3.5
7.4
33.67
10
Sl. Item No. No. 11 14.18 Filler joint Providing & fixing 20
mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
3 3 3 3
2 11.5
12 12 12 12 0.3
Unit Qty for 2Lane Nos. 36.00 Nos. 36.00 Nos. 36.00 Nos. 36.00 m3 27.60
12 14.10
13 14.11
11.5
0.3
m3
27.60
14
14.7
23.36
23.36
15
8.22
23.36
46.72
16
16.1
7.5
15.36
115.20
3 8.5
25.50 130.56
18
19
15
Nos.
30.00
20
Nos.
4.00
15
22
2 2
0.65
0.7+1.0 2
1 1
Total-
23
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no : 255/2 Ch-254750
Item No. 1 Total Quantity 4 Rate in Rs. 5
Unit 3
Amount (Rs.) 6
2/12.8
3/12.40
4/13.5
5/13.6
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
Cum
888.78
54.00
47,995.00
Cum Cum
94.05 236.87
6514.00 9030.00
612,660.00 2,138,891.00
tonne
33.33
73279.00
2,442,574.00
Cum
65.52
8120.00
532,023.00
Cum
88.45
9169.00
810,984.00
Item No. 1
Particulars/Descrption of items 2 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Tonne
11.96
73343.00
877,398.00
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4 Retro reflectorised Traffic sign:
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
Cum
107.02
10591.00
1,133,449.00
MT
7.31
77554.00
567,230.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
17.28
5200.00
89,856.00
Item Particulars/Descrption of items Unit No. 1 2 3 9/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications. 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 11/Analy HAND RAIL metre sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material metre
46.72 46.72
4170.00 1475.00
194,823.00 68,912.00
23.36
2044.00
47,748.00
Cum Cum,
28.80 2.40
12025.00 5498.00
346,320.00 13,196.00
Each
4.00
10197.00
40,788.00
RM
70.08
160.00
11,213.00
Cum
294.14
1524.00
448,276.00
Item Particulars/Descrption of items No. 1 2 18/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
Unit 3 Each
20/8.51
4.00
13,600.00 0.00
21/15.10
22/15.11
64.88 147.55
23/15.9
Cum
198.61
1679.00
333,467.00
Total-
14,126,863.00
Unit
Qty for 2Lane 396.29 11.52 8.63 147.56 54.43 103.68 101.10 65.58 888.78 0.00 27.65 34.56 18.14 13.70 94.05 0.00 184.32 9.00 11.15 32.40 236.87
2 2
21.86 21.86+15.36 2 2
m3 3 m 3 m m3 m3 m3 m3 m3 3 m
3
15 21.86 21.86
c/wall
12.8
m/wall
2 2 2
1 1.5 1.5 3
m3 m3 m3 m3
2 2
80 104
kg kg
Abutment = Pier cap Pier M/wall 6 13.5 Substructure (M20) PCC Wing wall-
2 2 2 1 1 2
0.65 0.7
0.7+1.0 2 0.225 1 0.2+0.45 2
26.55
kg
283.20
Sl. Item No. no. 12 Abutment cap = 12 12 12 12 32 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 2 2 2 0.78 10 1.85 10 1.85 60 27.3 16 m/wall 2 13.5 86 13.5 86 4.52 16 60 100 2 86
Qty for 2Lane 238.51 240.00 282.84 240.00 282.84 6857.01 776.53 2048.00 714.00 11962.94 11.96 107.02
Pier Cap
Abutment =
3.657 MT
7.31
10 14.18
12
Nos.
36.00
11
8.22
23.36 m
46.72
12
14.7
23.36 m
23.36
13 14.16
23.36 m2
70.08
14
14.4
8.50
23.36 m3
198.56
15
14.9
Nos.
Sl. Item No. no. 16 13.9 Back filling behind Abutment 2 12 4.00
,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. Reinforced cement concrete 2 approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course 2 below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery.
Unit 3.064 m3
17 14.11
0.3
4.00
12
m3
28.80
18 14.10
0.15
4.00
2.40
19
13.8
40
Nos.
40
20
8.47
Nos.
Sign board : Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 22 15.11 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall.
21
8.4
17.28
17.28
147.6 m3
147.55
23
198.6 m3
198.61
1 2
64.88 m3 23.36 m
64.88 46.72
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no -259/1,Ch-258170
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Amount (Rs.) 6
Cm Cm
0.00 151.97
356.00 573.00
0.00 87,078.00
3/12.8
(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
186.13
54.00
10,052.00
Cum Cum
5.61 32.70
6514.00 9030.00
36,521.00 295,305.00
4/12.40
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications tonne 3.27 73279.00 239,623.00
5/13.5
Item No. 1
Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel reinforcement bar of Fe-500 N/mm2
Unit 3
Amount (Rs.) 6
Cum
9.07
9169.00
83,156.00
6/13.6
(CRS) Tonne
0.76
73343.00
55,961.00
7/14.1
8/14.2
9/14.18
Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Cum
26.98
10591.00
285,724.00
tonne
2.16
77554.00
167,381.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete
Unit 3
Amount (Rs.) 6
metre metre
35.88 17.94
4170.00 2044.00
149,620.00 36,670.00
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud
11/14.7
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
2.00 20.00
10197.00 204.00
20,394.00 4,080.00
Each Each
4.00
3500.00 3400.00
13,600.00
Particulars/Descrption of items 2 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.
Unit 3 Each
18/16.1
Sqm
74.55
78.00
5,815.00
19/16.17 Replacement of Expansion Joints complete as per Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 85 b)16 mm dia re-bar fastners 25% of 85 C)20 mm dia re-bar fastners 25% of 85 d)25 mm dia re-bar fastners 25% of 85 20/16.2
metre Sqm
17.00 84.49
3628.00 59.00
61,676.00 4,985.00
Sqm
20.09
614.00
12,333.00
Unit Qty for 2Lane Cm 0.00 1.24 2.09 3.59 30.45 1.62 2.18 36.91 73.90 151.97 69.65 116.48 186.13 5.61 5.61 32.70 32.70 3270.00 3270.00 3.3 0.00 7.63 1.44 9.07 763.00 763.00 0.76 26.98 26.98 2158.24 2158.24 2.16 2.00 24.00 24.00 24.00 24.00 27.60 27.60
2 2
0.82
9.94
9.95 3.5
0.9 10 Cm 0.175 14.915 Cm 0.2 17.94 Cm 9.4 3.95 Cm 0.25 3.95 Cm 0.7+0.94 1.33 Cm 2 3.95 0.94 Cm 2 36.95 Cm Total= Cm 3 3.5 2 m 4.16 4.0 m3 Total= m3 0.15 m3 Total= 0.94 Total= 100 kg Total= kg Total= Tonne 3.50 0.82 Total= 100 Total= Total= 0.82 Total= 80 Total= Total= 1 12 12 12 12 0.3 0.3 m3
3
3 4
10.24 9.94
3.65 3.5
32.7
13.5 Substructure(M35)2 2
0.7+0.94 2
0.25
m Kg Kg
Tonne
8 9
3.5
9.4 26.978
m3 m3 Kg Kg
Tonne
10 11
2 2 2 2 2
2 11.5
12 13
4 4
11.5
15
17.94 m
35.88
16
7.5
9.94
74.55
17 18
2 8.5
17.00 84.49
19
10
Nos.
20.00
20
Nos.
4.00
21
10
Nos.
10.00
22
0.82 2
2
0.7+0.94 2
sqm sqm
0.94 0.82
23
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no : 259/1 ,Ch-258170
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35
Cum
652.60
54.00
35,241.00
Cum Cum
46.75 167.76
6514.00 9030.00
304,537.00 1,514,873.00
(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
tonne
18.02
73279.00
1,320,167.00
4/13.5
Cum
45.97
8120.00
373,277.00
Cum
37.09
9169.00
340,097.00
5/13.6
Item No.
Particulars/Descrption of items (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure
Unit Tonne
6/14.1
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v)80cmm x 45 cm rectangular
Cum
87.14
10591.00
922,900.00
MT
6.08
77554.00
471,219.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
10/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications.
17.28 152.49
5200.00 12993.00
89,856.00 1,981,303.00
Item No.
Particulars/Descrption of items
Unit
Total Quantity
Rate in Rs.
Amount (Rs.)
11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analys HAND RAIL is Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 19/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification metre metre 35.88 35.88 4170.00 1475.00 149,620.00 52,923.00
metre
17.94
2044.00
36,670.00
RM
53.82
160.00
8,612.00
Cum Each
206.40 40.00
1524.00 204.00
314,554.00 8,160.00
Item No.
Particulars/Descrption of items
Unit
Total Quantity
Rate in Rs.
Amount (Rs.)
20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 22/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 23/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 24/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 25/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
4.00
13,600.00 0.00
42.92 97.61
Cum
91.91
1679.00
154,317.00
Total-
9,623,198.00
Unit
Qty for 2Lane 336.37 7.46 9.00 97.61 67.10 24.81 66.88 43.38 652.60 0.00 16.28 8.10 22.37 46.75 0.00 119.28 9.00 7.08 32.40 167.76
2 2
15 2
14.46+9.94 2
m m3 m3 3 m m3 m3 m m3 Total = m m3 m3 m3 Total=
3 3
14.46 14.46
15
12.8
m/wall
2 2 2
2 2
110 80
12.94 15 100
Abutment M/wall-
2 2 2 2
0.82 0.7
0.7+1.0 2 0.2+0.45 2
0.25 12 1.105 3
12 0.225 12 3 Total=
m3 m3 m3
13.5 Substructure (M20) PCC Wing wall13.6 Reinforcement in substuctureDirt wall 12 mm dia
45.97 m3
45.97
26.55
Kg
283.20
Unit 12 Abutment cap 12 12 20 12 12 mm dia mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 2 M/wall 0.95 10 1.85 2 10 110 2 13.5 86 110 27.3 10 100 3.45 86 Kg Kg Kg Kg Kg 1 Kg 5.85 Kg Total = Kg Total = Tonne 87.14 m3
Qty for 2Lane 290.49 240.00 282.84 3748.15 485.33 1955.56 585.00 7870.57 7.87 87.14
Abutment -
14.2
6.076
MT
6.08
10 14.18
12
Nos.
24.00
11
8.22
17.94
35.88
12
14.7
17.94
17.94
13 14.16
17.94
m2
53.82
14
8.50
17.94
152.49
15 16
1 2 12 4.00
2 2.15
Nos. m3
2.00 206.40
18 14.10
0.15
4.00
12
m3 Nos.
14.40
19
13.8
40.00
20
8.47
Nos.
4.00
21
8.4
17.28
17.28
22 15.11
97.61
m3
97.61
23
91.91
m3
91.91
Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. 24 15.10 Curtain wall complete as per drawing and Technical specification. 25 Analys HAND RAIL is rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
1 2
42.92 17.94
m3 m
42.92 35.88
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-259/2 ,Ch-258380
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
49.24 93.99
356.00 573.00
17,530.00 53,856.00
3/12.8
(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
144.27
54.00
7,791.00
Cum Cum
5.22 34.79
6514.00 9030.00
33,994.00 314,154.00
4/12.40
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications
tonne
3.5
73279.00
254,938.00
Item No. 1
Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cum
13.99
9169.00
128,298.00
6/13.6
7/14.1
8/14.2
9/14.18
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper metre plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as metre per drawings and technical specifications with coarse sand and 6% bitumen by weight.
1.40
73343.00
102,534.00
26.98
10591.00
285,724.00
2.16
77554.00
167,381.00
24.00
1640.00
39,360.00
24.00
558.00
13,392.00
24.00
317.00
7,608.00
24.00
17.00
408.00
Particulars/Descrption of items
Unit 3
2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
35.88 17.94
4170.00 2044.00
149,620.00 36,670.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
2.00 30.00
10197.00 204.00
20,394.00 6,120.00
Each Each
4.00
3500.00 3400.00
13,600.00
Particulars/Descrption of items 2 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.
Unit 3 Each
18/16.1
Sqm
74.55
78.00
5,815.00
19/16.17 Replacement of Expansion Joints complete as per Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface. 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 87 b)16 mm dia re-bar fastners 25% of 87 C)20 mm dia re-bar fastners 25% of 87 d)25 mm dia re-bar fastners 25% of 87 20/16.2
metre Sqm
17.00 84.49
3628.00 59.00
61,676.00 4,985.00
Sqm
14.34
614.00
8,803.00
Total-
Unit
Qty for 2Lane 49.24 1.24 2.09 3.59 30.45 1.62 15.75 39.26 93.99 41.79 102.48 144.27 5.22 5.22 34.79 34.79 3479.00 3479.00 3.5 12.56 1.44 13.99 1398.00 1398.00 1.4 26.98 26.98 2158.24 2158.24 2.16 2.00
Cm Cm Cm Cm Cm Cm Cm Cm Cm m3 m3
12.1
Earth work in or foundation of structures as per drawings & technical specification including setting out.(Upto 3m)PCC M15RCC M35 (open foundation)-
3 4 5
12.8 12.8
9.94 9.94
13.5
Substructure(M35)-
2 2 7 13.6
Reinforcement in Substructure-
0.7+1.0 2
0.25
8 9
14.1 14.2
3.5
9.4 26.978
10
14.9
Drainage Spouts complete as per drawing and Technical specification. mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
0.82 Total= m3 100 Kg Kg Total= Total= Tonne 0.82 m3 Total= m3 80 Kg Kg Total= Total= Tonne 2 Nos.
11
2 2 2 2
2 11.5
12 12 12 12 0.3
12
Unit
2 11.5
0.3
m3
14
14.7
17.94
17.94
15
8.22
17.94
35.88
16
16.1
7.5
9.94
74.55
17
8.5
17.00
18
16.2
Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe. Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.
8.5
9.94
metre
84.49
19
13.8
15
Nos.
30.00
20
8.47
Nos.
4.00
21
8.51
10
Nos.
10.00
Unit 0.82
2
2
0.7+1.0 2
Qty for 2Lane sqm 0.41 sqm 3.99 sqm 9.94 14.34 87
23
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
52.42 0.6
sqm Each
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no: 259/2, Ch-258380
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel Cum
730.30
54.00
39,437.00
47.82 167.76
6514.00 9030.00
311,494.00 1,514,873.00
tonne
15.02
73279.00
1,100,669.00
Cum
67.68
8120.00
549,562.00
Cum
57.80
9169.00
529,950.00
Item No. 1
Total Rate in Quantity Rs. 2 3 4 5 (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne 11.94 73343.00 bar of Fe-500 N/mm2 Super Structure Particulars/Descrption of items Unit
in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
Cum
87.14
10591.00
922,900.00
MT
6.08
77554.00
471,219.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
9/14.4 Providing and laying Cement concrete wearing coat M- m3 30 grade including reinforcement complete as per drawing and Technical Specifications.
17.28 152.49
5200.00 12993.00
89,856.00 1,981,303.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
35.88 35.88
4170.00 1475.00
149,620.00 52,923.00
metre
17.94
2044.00
36,670.00
RM
53.82
160.00
8,612.00
Cum
303.84 40.00
1524.00 204.00
463,053.00 8,160.00
18/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
Item No.
Particulars/Descrption of items
Unit 3
1 2 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 21/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
4.00
13,600.00 0.00
49.39 112.32
Cum
107.16
1679.00
179,922.00
Total- 10,321,246.00
Unit
Earth work or foundation of structures as per drawings & technical specification including setting out.
Qty for 2Lane 375.73 7.46 9.00 112.32 67.10 31.82 76.96 49.92 730.30 0.00 16.28 9.17 22.37 47.82 0.00 119.28 9.00 7.08 32.40 167.76
12.1
2 2
m m3 m3 m3 3 m m3 m3 3 m
15 2 16.64+9.94
2
16.64 16.64
12.8
15
Total= 3 12.8
RCC M35(open foundation)
m/wall
2 2 2
12.40
2 2
12.94 80
80 15 100
13.5
Abutment M/wall
2 2 2 2
0.82 0.7
0.7+1.0 2 0.2+0.45 2
0.25 12 2.12 3
12 0.225 12 3 Total=
m3 m3 3 m m3
13.5
67.68
m3
67.68
13.6
2 2
6 0.95
26.55 2
86.00
kg kg
283.20 290.49
Unit 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 10 1.85 2 15 15 m/wall 13.5 86 100 27.3 100 100 4.45 kg kg kg kg 1 kg 5.85 kg Total = kg Total = Tonne 87.14 m3
Qty for 2Lane 240.00 282.84 6867.28 728.00 2666.67 585.00 11943.48 11.94 87.14
Abutment =
14.1
14.2
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing 2 wall and Return Wall complete as per drawing and technical specification with Granular Material. Reinforced cement concrete 2 approach slab including reinforcement and formwork complete as per drawing and Technical
6.076
MT
6.08
10
14.18
12
Nos.
24.00
11
8.22
17.94
35.88
12
14.7
17.94
17.94
13
14.16
17.94
m2
53.82
14
14.4
8.50
17.94
m3
152.49
15 16
14.9 13.9
1 12 4.00
2 3.165
Nos. m3
2.00 303.84
17
14.11
0.3
4.00
12
m3
28.80
Unit
PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Sign board : Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification. Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
18
14.10
0.15
4.00
12
m3
19
13.8
40
Nos.
40.00
20
8.47
Nos.
4.00
21
15.11
112.32
112.32
22
8.4
17.28
m2
17.28
23
15.9
107.16
m3
107.16
24
15.10
1 2
49.39 17.94
49.39 35.88
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-259/3 ,Ch-258590 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
92.14 352.71
356.00 573.00
32,802.00 202,102.00
2/12.1
3/12.8
(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
419.50
54.00
22,653.00
Cum Cum
15.11 151.10
6514.00 9030.00
98,424.00 1,364,388.00
4/12.40
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 tonne 15.11 73279.00 1,107,210.00
Particulars/Descrption of items 2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cum
61.51
9169.00
564,008.00
6/13.6
Tonne
6.15
73343.00
451,133.00
7/14.1
Cum
80.93
10591.00
857,172.00
8/14.2
tonne
6.47
77554.00
502,141.00
9/14.18
metre
48.00
1640.00
78,720.00
metre
48.00
558.00
26,784.00
Item No. 1
Particulars/Descrption of items 2 (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete Construction of RCC railing of M30 Grade insitu with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
Unit 3 metre
metre
48.00
17.00
816.00
10/8.22
11/14.7
metre metre
73.56 36.78
4170.00 2044.00
306,746.00 75,179.00
12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Cum Cum 27.60 27.60 12025.00 5498.00 331,890.00 151,745.00
Each Each
6.00 30.00
10197.00 204.00
61,182.00 6,120.00
Particulars/Descrption of items 2 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
17/8.51
4.00 18.00
13,600.00 5,364.00
18/16.1
Sqm
215.85
78.00
16,837.00
19/16.17 Replacement of Expansion Joints complete as per Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 272 b)16 mm dia re-bar fastners 25% of 272 C)20 mm dia re-bar fastners 25% of 272 d)25 mm dia re-bar fastners 25% of 272 20/16.2
metre Sqm
34.00 244.63
3628.00 59.00
123,352.00 14,434.00
Sqm
62.65
614.00
38,469.00
Total-
Item No. 1
Particulars/Descrption of items 2
Unit 3
Total Rate in Amount (Rs.) Quantity Rs. 4 Executive 5 Engineer, PWD 6 Nagaon NH Division, Nagaon
46.07 20 31.55 36.78 3.95 3.95 3.95 3.95 3.95 Total= 3.15 4.0 Total= 0.15 Total= 1.5 Total= 100 Total= Total= 4.541 3.15 0.82 Total= 100 Total= Total= 0.82 Total= 80 Total= Total= 2 12 12 12 12 0.3
Cm Cm Cm Cm Cm Cm Cm Cm Cm Cm 3 m 3 m m3 m3
92.14 2.48 4.42 7.36 91.34 1.62 39.11 35.87 170.52 352.71 317.30 102.20
2
Raft-
12.1
Earth work in or foundation of structures as per drawings & technical specification including setting out.(Upto 3m)PCC M15RCC M35 (open foundation)-
3 4 5
12.8 12.8
28.78 28.78
13.5
Substructure(M35)-
2 2 2
0.7+1.5 2
1.00
419.50 15.11 15.11 151.10 151.10 kg 15109.50 kg 15109.50 Tonne 15.11 31.47 m3 m3 Kg Kg
Tonne
0.25
13.6
Reinforcement in Substructure-
8 9
14.1 14.2
3.5
9.4 80.934
m3 m3 Kg Kg
Tonne
10 11
12
13
14.9 Drainage Spouts complete as per drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification.
3 4 4 4 4
2 11.5
28.61 1.44 61.51 6151.00 6151.00 6.15 80.93 80.93 6474.72 6474.72 6.5 6.00 48.00 48.00 48.00 48.00 27.60
11.5
0.3
m3
27.60
Sl.No 14
15
16
17 18
19
Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 8.22 Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe,
36.78
36.78
73.56
7.5
28.78
215.85
4 8.5
34.00 244.63
15
Nos.
30.00
20
8.47
Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.
Nos.
4.00
21
8.51
18
Nos.
18.00
22
0.82
2
2
0.7+1.5 2
1 28.78
Total- sqm
Sl.No 23
Item No.
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no : 259/3 , Ch-258590
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35
Cum
2221.38
54.00
119,955.00
Cum Cum
248.18 580.65
6514.00 9030.00
1,616,649.00 5,243,270.00
(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
tonne
61.57
73279.00
4,511,428.00
Cum
194.89
8120.00
1,582,507.00
Cum
242.08
9169.00
2,219,617.00
5/13.6
Item No. 1
Particulars/Descrption of items
Unit
2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
45.96
73343.00
3,370,806.00
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
Cum
261.42
10591.00
2,768,700.00
MT
18.23
77554.00
1,413,655.00
metre
48.00
1640.00
78,720.00
metre
48.00
558.00
26,784.00
metre
48.00
317.00
15,216.00
metre
48.00
17.00
816.00
17.28
5200.00
89,856.00
Item No.
Particulars/Descrption of items
Unit
1 2 3 10/14.4 Providing and laying Cement concrete wearing m3 coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing metre metre
77.56 73.56
4170.00 1475.00
323,426.00 108,501.00
metre
36.78
2044.00
75,179.00
Cum Cum,
28.80 14.40
12025.00 5498.00
346,320.00 79,172.00
Each
6.00
10197.00
61,182.00
RM
110.34
160.00
17,655.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 19/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
22/15.10 Curtain wall complete as per drawing and Technical
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cum Each
514.66 40.00
1524.00 204.00
784,336.00 8,160.00
4.00
13,600.00 0.00
specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
119.25 271.21
Cum
371.14
1679.00
623,145.00
Total-
30,803,640.00
2 2 2
m3 m3 m3 3 m 3 m m m3 m3
3
1264.02 21.59 8.63 271.22 176.88 172.68 185.83 120.54 2221.38 0.00 51.80 64.76 117.92 13.70 248.18
15 40.18 40.18
12.8
28.78 15 5.7 1
m3 m3 m3 m3
12.8
m3 12 0.25 0.25 1.2 1.5 1.5 1.5 3 28.78 12 28.28 4.5 Total= m3 m3 m
3
m/wall
2 2 2
12.40
2 2
160 192
2 81.5
kg kg kg kg
13.5
Abutment Pier Cap Pier M/wall 6 13.5 Substructure (M20) PCC Wing wall-
2 2 2 2 2 2
12 12 4.316 12 12 5.36
m 3 m m3 m3 m3 3 m
194.89
m3
194.89
Sl. No. 7
Item no. 13.6 Reinforcement in substuctureDirt wall = 12 mm dia 12 mm dia Abutment cap = 12 12 Abutment = 28 12 12 12 12 28 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia
Unit Qty for 2Lane 2 2 2 2 2 2 2 2 2 2 2 6 0.78 10 1.85 2 2 120 10 1.85 2 29 80 m/wall 26.55 2 13.5 86 120 29 29 13.5 86 80 27.3 29 100 7.14 7.14 27.3 1.25 Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg 283.20 238.51 240.00 282.84 16585.96 1407.47 7733.33 240.00 282.84
86
Pier Cap
Pier
14.1
14.2
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification.
11057.30 1407.47 1.25 5155.56 10.45 1045.00 Total = 45959.48 Total = Tonne 45.96 3 87.14 261.42 m
6.076
MT
18.23
10
14.18
12
Nos.
48.00
11
8.22
38.78
77.56
12
14.7
36.78
36.78
13
14.16
36.78
m2
110.34
14
14.4
36.78
8.5
m3
312.63
15
14.9
Nos.
Sl. No. 16
17
14.11
0.3
4.00
12
m3
28.80
18
14.10
0.15
4.00
12
m3
14.40
19
13.8
40
Nos.
40
20
8.47
Nos.
21
8.4
17.28
m2
17.28
22
15.11
271.21
m3
271.21
23
15.9
371.14
m3
371.14
24 25
15.10
Analysis rate
1 2
119.25 36.78
119.25 73.56
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-260/1, Ch-259015 m
Total Quantity 4 Rate in Rs. 5
Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Amount (Rs.) 6
Cm Cm
64.12 199.50
356.00 573.00
22,827.00 114,312.00
2/12.1
3/12.8
(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications
Cum
262.93
54.00
14,199.00
Cum Cum
11.21 74.76
6514.00 9030.00
73,048.00 675,083.00
4/12.40
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m
7.48
73279.00
547,834.00
Item No. 1
Particulars/Descrption of items
Unit
6/13.6
7/14.1
8/14.2
9/14.18
2 3 Case II : With Batching plant, Transit Mixer and Cum concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate metre in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre metre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per metre drawings and technical specifications with coarse sand and 6% bitumen by weight. Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre
2.57
73343.00
188,125.00
65.52
10591.00
693,923.00
5.24
77554.00
406,508.00
36.00
1640.00
59,040.00
36.00
558.00
20,088.00
36.00
317.00
11,412.00
36.00
17.00
612.00
10/8.22
58.72
4170.00
244,863.00
Particulars/Descrption of items
Unit
2 3 Construction of RCC railing of M30 Grade in-situ with metre 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 13/14.10 PCC M15 grade levelling course below approach slab Cum complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Each Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 17/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat Sqm including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per drawings. metre 16/8.47 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned 20/16.2 Sqm
4.00 14.00
13,600.00 4,172.00
160.20
78.00
12,496.00
25.50 181.56
3628.00 59.00
92,514.00 10,713.00
Sqm
29.45
614.00
18,085.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 190 b)16 mm dia re-bar fastners 25% of 190 C)20 mm dia re-bar fastners 25% of 190 d)25 mm dia re-bar fastners 25% of 190
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Unit
Qty for 2Lane 64.12 1.98 3.49 5.87 73.94 1.78 19.01 11.18 82.24 199.50 160.73 102.20 262.93 11.21 11.21 74.76 74.76 7476.00 7476.00 7.48 15.16 8.92 1.58 25.65 2565.00 2565.00 2.57 65.52 65.52 5241.60 5241.60 5.24 4.00
32.06 16 24.96 29.36 3.95 3.95 2.831 2.831 3.85 Total= 2.15 4.0 Total= 0.15 Total= 1 Total= 100 Total= Total= 2.831 2.83 0.90 Total= 100 Total= Total= 3.5 Total= 80 Total= Total= 2
Cm Cm Cm Cm Cm Cm Cm Cm Cm Cm
1
Raft-
m3 m3 m3 m3
3 4 5
21.36 21.36
kg kg
Tonne
13.5
Substructure(M35)-
2 1 2
0.7+1.0 2
1.00
m3 m3 Kg Kg
Tonne
0.25
8 9
0.9
10.4 65.52
m3 m3 Kg Kg
Tonne
10
Nos.
11
3 3 3 3
2 11.5
12 12 12 12 0.3
12
Unit
2 11.5
0.3
m3
14
29.36
29.36
15
29.36
58.72
16
7.5
21.36
160.20
17
8.5
25.50
18
8.5
21.36
metre
181.56
19
20
Nos.
40.00
20
Nos.
4.00
21
14
Nos.
14.00
Unit 0.9
2
2
0.7+1.0 2
1 21.36
23
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no: 260/1,Ch-259015
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of foundation
of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum 2/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum
1473.56
54.00
79,573.00
130.64 441.90
6514.00 9030.00
850,989.00 3,990,357.00
3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
29.14
73279.00
2,135,459.00
79.76
8120.00
647,652.00
101.13
9169.00
927,270.00
Item No. 1
Total Rate in Amount (Rs.) Quantity Rs. 2 3 4 5 6 (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne 26.47 73343.00 1,941,433.00 bar of Fe-500 N/mm2 Super Structure Particulars/Descrption of items Unit
in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
Cum
212.80
10591.00
2,253,765.00
MT
14.09
77554.00
1,093,047.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
10/14.4 Providing and laying Cement concrete wearing coat M- m3 30 grade including reinforcement complete as per drawing and Technical Specifications.
17.28 249.56
5200.00 12993.00
89,856.00 3,242,534.00
Item Particulars/Descrption of items No. 1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. (i) 'M 20 grade concrete 12/Anal HAND RAIL ysis Providing and fixing hand rail over the crash barrier Rate consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
58.72 58.72
4170.00 1475.00
244,863.00 86,612.00
metre
29.36
2044.00
60,012.00
RM
88.08
160.00
14,093.00
(A) Granular material Cum 19/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
358.08 30.00
1524.00 204.00
545,714.00 6,120.00
Item Particulars/Descrption of items No. 1 2 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
4.00
13,600.00 0.00
87.14 198.18
Cum
235.47
1679.00
395,355.00
Total- 20,084,023.00
Unit
Qty for 2Lane 807.41 16.02 8.63 198.18 91.30 128.16 135.79 88.08 1473.56
2 2 2
m m3 m3 3 m m3 m3 3 m m3 m3
15 29.36 29.36
12.8
21.36 15 4 1
m3 m3 m3 m3
3
38.45 48.06 30.43 13.70 130.64 0.00 384.48 9.00 16.02 32.40 441.90
c/wall
Total= m 3 12.8
RCC M35(open foundation)
m3 12 0.25 0.25 1.2 1.5 1.5 1.5 3.00 21.36 12 21.36 4.5 Total= m3 m3 3 m m3
M/wall
2 2 2
12.40
2 2
100 155
2 70.5
kg kg kg kg
13.5
2 2 2 0
12 0.7 12 12 12 3 Total=
m 3 m m3 m3 m3 3 m m3
0.2+0.45 2
Sl. Item no. No. 6 13.5 Substructure (M20) PCC Wing wallReinforcement in substuctureDirt wall 12 mm dia 12 mm dia
Abutment cap
Unit
79.76 m3
79.76
13.6
2 2 2 2 2 2 2 2 2 2
86
kg kg kg kg
12 12 25 12 12 25 12 12
Abutment
4.95 1.25
kg kg kg
Pier
kg 3743.06 kg 873.60 1.25 kg 3920.00 7.27 kg 727.00 Total = kg 26470.58 Total = Tonne 26.47 106.40 m3 212.80
14.1
14.2
10
14.18
11
8.22
12
14.7
13
14.16
14
14.4
15
14.9
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification.
7.047
MT
14.09
12
Nos.
36.00
29.36
58.72
29.36
29.36
29.36
88.08
8.50
29.36
m3
249.56
Nos.
Sl. Item no. No. 16 13.9 Back filling behind Abutment ,Wing
wall and Return Wall complete as per drawing and technical specification with Granular Material. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
17
14.11
0.3
4.00
12
28.80
18
14.10
0.15
4.00
12
14.40
19
20
21
22
23
24 25
Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, 8.47 Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm Sign board : Retro reflectorised 8.4 Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per 15.11 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg 15.9 Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. 15.10 Curtain wall complete as per drawing and Technical specification. Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts,
13.8
Nos.
30
Nos.
17.28
17.28
198.18 m3
198.18
235.47 m3
235.47
1 2
87.14 29.36
m3 m
87.14 58.72
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-260/2, Ch-259230 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
100.76 207.60
356.00 573.00
35,871.00 118,954.00
(i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 4/12.40 Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications
Cum
386.49
54.00
20,871.00
Cum Cum
8.57 80.64
6514.00 9030.00
55,851.00 728,180.00
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35
8.06
73279.00
590,922.00
Item No. 1
Particulars/Descrption of items 2 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Unit 3 Cum
6/13.6
Tonne
6.16
73343.00
451,867.00
7/14.1
Cum
33.15
10591.00
351,113.00
8/14.2
tonne
2.69
77554.00
208,900.00
9/14.18
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
Item No.
Particulars/Descrption of items
Unit
1 2 3 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 13/14.10 PCC M15 grade levelling course below approach slab Cum complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Each Each
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
46.72 23.36
4170.00 2044.00
194,823.00 47,748.00
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
4.00 50.00
10197.00 204.00
40,788.00 10,200.00
4.00 15.00
13,600.00 4,470.00
Item No.
Particulars/Descrption of items
Unit 3 Sqm
1 2 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per drawings. 20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 192 b)16 mm dia re-bar fastners 25% of 192 C)20 mm dia re-bar fastners 25% of 192 d)25 mm dia re-bar fastners 25% of 192
metre Sqm
25.50 130.56
3628.00 59.00
92,514.00 7,704.00
Sqm
52.65
614.00
32,325.00
Total-
Unit Qty for 2Lane 2 0.9 0.175 0.2 7.4 0.65 5.4 5.4 3.95 3.5 6.15 50.38 13 19.785 23.36 3.95 3.95 3.95 3.95 1.5 Total= 3.95 4.0 Total= 0.15 Total= 1.5 Total= 100 Total= Total= 5.4 5.40 0.25 Total= 100 Total= Total= 0.64 Total= 80 Total= Total= 2 12 12 12 12 0.3 m3 m3 Kg Kg
Tonne
Cm Cm Cm Cm Cm Cm Cm Cm Cm Cm m3 m3 m3 m3
100.76 1.61 2.77 4.67 38.00 1.28 46.93 21.33 91.01 207.60 214.29 172.20 386.49 8.57 8.57 80.64 80.64 8064.00 8064.00 8.06 41.58 18.90 1.14 61.62 6161.00 6161.00 6.16 33.15 33.15 2693.60 2693.60 2.69 4.00 36.00 36.00 36.00 36.00 27.60
1
Raft-
3 4 5
15.66 15.36
kg kg
Tonne
13.5 Substructure(M35)-
2 2
0.7+1.5 2
1.00
0.65
8 9
3.5
7.4 33.67
m3 m3 Kg Kg
Tonne
10
2 3 3 3 3 4
drawing and Technical specification. 11 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
11.5
11.5
0.3
27.60
23.36
15
23.36
46.72
16
7.5
15.36
115.20
wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 17 16.17 Replacement of Expansion Joints complete as per drawings. 18 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.
3 8.5
25.50 130.56
19
25
Nos.
50.00
20
Nos.
4.00
21
15
Nos.
15.00
marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification. 22 16.28 Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface.
2
2
0.65
0.7+1.5 2
1 1.5
Total- sqm
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no : 260/2, Ch-259230,
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
1127.00
54.00
60,858.00
Cum Cum
118.09 329.03
6514.00 9030.00
769,264.00 2,971,096.00
3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Cum Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2
38.23
73279.00 2,801,450.00
394.25
8120.00
3,201,310.00
222.07
9169.00
2,036,137.00
46.45
73343.00 3,406,448.00
Item No. 1
Unit 3
Amount (Rs.) 6
6/14.1
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
Cum
107.02
10591.00 1,133,449.00
MT
7.31
77554.00
567,230.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
10/14.4 Providing and laying Cement concrete wearing coat M-30 m3 grade including reinforcement complete as per drawing and Technical Specifications.
17.28 198.56
Item No.
Particulars/Descrption of items
Unit 3
1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
Amount (Rs.) 6
B. M 40 grade concrete metre 12/Analys HAND RAIL metre is Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineerin-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 15/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Technical Each specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing RM 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum 19/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
46.72 46.72
4170.00 1475.00
194,823.00 68,912.00
23.36
2044.00
47,748.00
70.08
160.00
11,213.00
580.80 80.00
1524.00 204.00
885,140.00 16,320.00
Item No.
Particulars/Descrption of items
Unit
1 2 3 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures a) Bi-directional Stud Each b) Uni-directional Stud Each 21/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
22/15.10 Curtain wall complete as per drawing and Technical
Amount (Rs.) 6
4.00
13,600.00 0.00
specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
83.34 189.54
Cum
228.00
1679.00
382,812.00
Total- 22,663,670.00
Unit
Qty for 2Lane 488.45 11.52 8.63 194.81 126.56 103.68 106.78 86.58 1127.00
2 2
28.86 2 28.86+15.36 2
m m3 m3 3 m m3
15 28.86 28.86
0.45 m3 3 2 m 2 m3 Total =
15.36 15 6.36 1
m3 m3 m3 m3
c/wall
12.8
m3 12 0.25 0.25 1.2 1.5 1.5 1.5 3 15.36 12 14.86 4.5 Total= m3 m3 3 m m3 276.48 9.00 11.15 32.40 329.03
m/wall
2 2 2
2 2
100 104
54.72 2
kg kg kg kg
32.4 kg 3240.00 Total = kg 38229.91 Total = Tonne 38.23 0.25 0.225 12 12 12 3 Total= m m3 3 m m3 m3 3 m
3
2 2 2 1 1 2
13.5
394.25 m3
Unit
Qty for 2Lane 283.20 238.51 240.00 282.84 240.00 282.84 20859.26 1698.67 8400.00
2 2 2 2 2 2 2 2 2 2 2 2
86
kg kg kg kg kg kg
12 12 12 12 32 12 12 32 12 12
mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia
Pier cap
Abutment
8.25 1.35
kg kg kg
Pier
kg 6257.78 kg 1698.67 1.25 kg 4666.67 12.97 kg 1297.00 Total = kg 46445.43 Total = Tonne 46.45 53.51 m3 107.02
14.2
3.657
MT
7.31
12
Nos.
36.00
11
8.22
23.36
46.72
12
23.36
23.36
13
23.36
70.08
14
8.50
23.36
m3
198.56
0.3
4.00
12
m3
28.80
18 14.10
19
13.8
20
8.47
21
8.4
22 15.11
23
15.9
24 15.10 25 Analysi
s rate
approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course 2 below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom shank to the top Sign board : Retroof reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 madeFlexible of high intensity Stone apron Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. Curtain wall complete as per drawing and Technical specification. HAND RAIL Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
0.15
4.00
12
m3 Nos.
14.40
40
80
Nos.
17.28
m2
17.28
189.54 m3
189.54
228.00 m3
228.00
1 2
83.34 23.36
m3 m
83.34 46.72
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no- 260/4,Ch-259580
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
42.58 128.52
356.00 573.00
15,159.00 73,644.00
3/12.8
(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
296.45
54.00
16,009.00
Cum Cum
8.57 53.76
6514.00 9030.00
55,851.00 485,453.00
4/12.40
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications tonne 5.38 73279.00 393,948.00
5/13.5
Item No. 1
Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cum
18.43
9169.00
168,994.00
6/13.6
Tonne
1.84
73343.00
135,135.00
7/14.1
Cum
33.67
10591.00
356,599.00
8/14.2
tonne
2.69
77554.00
208,900.00
9/14.18
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
B. M 40 grade concrete Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 11/14.7
metre metre
46.72 23.36
4170.00 2044.00
194,823.00 47,748.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
4.00 20.00
10197.00 204.00
40,788.00 4,080.00
Each Each
4.00
3500.00 3400.00
13,600.00
Particulars/Descrption of items 2 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.
Unit 3 Each
18/16.1
Sqm
115.20
78.00
8,986.00
19/16.17 Replacement of Expansion Joints complete as per Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 177 b)16 mm dia re-bar fastners 25% of 177 C)20 mm dia re-bar fastners 25% of 177 d)25 mm dia re-bar fastners 25% of 177 20/16.2
metre Sqm
25.50 130.56
3628.00 59.00
92,514.00 7,704.00
Sqm
28.63
614.00
17,577.00
Total-
Unit
Qty for 2Lane 42.58 1.61 2.77 4.67 38.00 1.28 12.29 7.23 60.67 128.52 141.05 155.40 296.45 8.57 8.57 53.76 53.76 5376.00 5376.00 5.4 10.89 6.41 1.14 18.43 1842.50 1842.50 1.84 33.67 33.67 2693.60 2693.60 2.69 4.00
21.29 Cm 13 19.785 23.36 3.95 3.95 3.95 3.95 1 Total= 2.6 4.0 Cm Cm Cm Cm Cm Cm Cm Cm Cm 3 m 3 m
1
Raft-
15.66
3.65
Total= m3 0.15 m3 Total= 1 Total= 100 kg Total= kg Total= Tonne 1.83 1.83 0.25 Total= 100 Total= Total= 0.65 Total= 80 Total= Total= 2 m3 m3 Kg Kg
Tonne
15.36
3.5
53.76
13.5 Substructure(M35)-
2 2
0.7+1.0 2
1.00
0.65
8 9
3.5
7.4 33.67
m3 m3 Kg Kg
Tonne
10
Nos.
11
3 3 3 3
12 12 12 12
Unit
2 11.5
0.3
13 14.11
11.5
0.3
27.60
14
14.7
23.36
23.36
15
8.22
23.36
46.72
16
16.1
7.5
15.36
115.20
17 16.17 18 16.2
3 8.5
25.50 130.56
19
13.8
10
Nos.
20.00
20
8.47
Nos.
4.00
Unit 15 Nos.
2
2
0.65
0.7+1.0 2
1 1
Total- sqm
23
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
177
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing br Ch-259580
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35
Cum
970.04
54.00
52,382.00
Cum
89.73 236.82
6514.00 9030.00
584,499.00 2,138,485.00
(II) Using Batching plant Transit mixer and concrete Cum pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
22.80
73279.00
1,670,595.00
52.96
8120.00
430,036.00
86.29
9169.00
791,151.00
Item No. 1
Particulars/Descrption of items
Unit
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure
concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
18.61
73343.00
1,364,955.00
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
Cum
107.02
10591.00
1,133,449.00
MT
7.31
77554.00
567,230.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
17.28
5200.00
89,856.00
Item No.
Particulars/Descrption of items
Unit
1 2 3 10/14.4 Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications. 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 12/Analy HAND RAIL metre sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ metre with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 15/14.10 PCC M15 grade levelling course below approach Cum, slab complete as per drawing and technical specification 16/14.9 Drainage Spouts complete as per drawing and Each Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing RM 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum
46.72 46.72
4170.00 1475.00
194,823.00 68,912.00
23.36
2044.00
47,748.00
28.80 14.40
12025.00 5498.00
346,320.00 79,172.00
4.00
10197.00
40,788.00
70.08
160.00
11,213.00
237.79
1524.00
362,396.00
Item No.
Particulars/Descrption of items
Unit 3 Each
1 2 19/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 21/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
4.00
13,600.00 0.00
59.59 135.54
Cum
145.14
1679.00
243,691.00
Total-
13,529,613.00
Unit
Qty for 2Lane 516.10 11.52 8.63 135.54 41.46 103.68 92.87 60.24 970.04 27.65 34.56 13.82 13.70 89.73
2 2 2
m3 m3 m3 3 m 3 m
15.36 15 2.6 1
12.8
2 2 2
1 1.5 1.5 3
m m3 m3 m3
184.32 9.00 11.10 32.40 236.82 9718.52 8710.32 480.00 648.89 3240.00 22797.73 22.80
2 2
kg kg kg kg kg kg
Tonne
13.5
2 2 2 1 1 2
m3 3 m m3 m3 m3 3 m
3.90 3.78 32.68 2.70 19.22 24.00 86.285 52.96 283.20 238.51
0.2+0.45 2
6 7
13.5 13.6
1 2 2 6 0.78 26.55 2
52.96 m3 kg kg
86
Unit 12 12 12 12 25 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia 2 2 1 1 2 2 2 2 2 2 10 1.85 10 1.85 2 27.3 100 100 27.3 100 m/wall 13.5 86 13.5 86 100 11 11 3.95 11 11 100 3.95 1.2 kg kg kg kg kg kg kg
Qty for 2Lane 240.00 282.84 120.00 141.42 6095.68 533.87 2346.67
Pier cap
Abutment
Pier
14.1
14.2
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification.
kg 3047.84 kg 533.87 1.2 kg 2346.67 24 2400.00 m3 Total = kg 18610.56 Total = Tonne 18.61 53.51 m3 107.02
3.657
MT
7.31
10
12
Nos.
36.00
11
8.22
12
14.7
Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing
23.36
46.72
23.36
23.36
13
23.36
m2
70.08
14
14.4
15
14.9
Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification.
8.50
23.36
198.56
Nos.
Sl. Item no. No. 16 13.9 Back filling behind Abutment ,Wing
wall and Return Wall complete as per drawing and technical specification with Granular Material.
17
0.3
4.00
12
m3
28.80
18
14.10
0.15
4.00
12
m3
14.40
19
13.8
Nos.
30
20
8.47
Nos.
21
8.4
17.28
m2
17.28
22
15.11
135.54 m3
135.54
23
15.9
145.14 m3
145.14
24
15.10
59.59
m3 m
59.59
23.36
46.72
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no- 260/5, Ch-259685 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
44.90 129.93
356.00 573.00
15,985.00 74,450.00
(i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 4/12.40
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
Cum
208.39
54.00
11,254.00
Cum
8.57
6514.00
55,851.00
Cum
53.76
9030.00
485,453.00
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel reinforcement bar of Fe-500 N/mm2 (CRS) tonne 5.4 73279.00 393,948.00
Particulars/Descrption of items 2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cum
19.68
9169.00
180,432.00
6/13.6
Tonne
1.97
73343.00
144,244.00
7/14.1
Cum
33.67
10591.00
356,599.00
8/14.2
tonne
2.69
77554.00
208,900.00
9/14.18
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
Item No. 1
Particulars/Descrption of items
Unit 3 metre
2 (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).
metre metre
46.72 23.36
4170.00 2044.00
194,823.00 47,748.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
4.00 24.00
10197.00 204.00
40,788.00 4,896.00
Item No. 1
Particulars/Descrption of items 2 a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
17/8.51
18/16.1
Sqm
115.20
78.00
8,986.00
metre Sqm
25.50 130.56
3628.00 59.00
92,514.00 7,704.00
Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 192 b)16 mm dia re-bar fastners 25% of 192 C)20 mm dia re-bar fastners 25% of 192 d)25 mm dia re-bar fastners 25% of 192
20/16.2
Sqm
28.13
614.00
17,274.00
Total-
Unit Qty for 2Lane 22.45 13 19.785 23.36 3.95 3.95 1.962 3.95 1 Total= 1.88 4.0 Total= 0.15 Total= 1 Total= 100 Total= Total= 1.962 1.96 m3 0.25 Total= m3 100 Kg Total= Kg Total= Tonne 0.65 m3 Total= m3 80 Kg Total= Kg Total= Tonne 2 12 12 12 12 Nos. Nos. Nos. Nos. Nos. Cm Cm Cm Cm Cm Cm Cm Cm Cm Cm 3 m m3 m3 m3 44.90 1.61 2.77 4.67 38.00 1.28 13.17 7.75 60.67 129.93 101.99 106.40 208.39 8.57 8.57 53.76 53.76 5376.00 5376.00 5.4 11.67 6.87 1.14 19.68 1966.70 1966.70 1.97 33.67 33.67 2693.60 2693.60 2.69 4.00 36.00 36.00 36.00 36.00
0.9 0.175 0.2 7.4 0.65 3.95 1.962 3.95 3.5 3.8
1
Raft-
3 4 5
15.66 15.36
kg kg
Tonne
13.5 Substructure(M35)-
2 2
0.7+1.0 2
1.00
0.65
19.667
3.5
7.4
33.67
10 11
2 3 3 3 3
11.5
0.3
13
11.5
0.3
27.60
14
23.36
23.36
15
23.36
46.72
16
7.5
15.36
sqm
115.20
17
8.5
metre
25.50
18
8.5
15.36
metre
130.56
19
12
Nos.
24.00
20
Nos.
4.00
15
22
2
2
0.65
0.7+1.0 2
1 1
Total- sqm
23
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
192
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no : 260/5,Ch-259685
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35
Cum
950.61
54.00
51,334.00
Cum Cum
91.29 236.82
6514.00 9030.00
594,652.00 2,138,485.00
(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications.
4/13.5
5/13.6
(A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
19.20
73279.00
1,406,954.00
55.84
8120.00
453,421.00
90.99
9169.00
834,332.00
Item No. 1
Particulars/Descrption of items
Unit
2 3 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure
and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
18.90
73343.00
1,386,270.00
6/14.1 Furnishing
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
Cum
107.02
10591.00
1,133,449.00
MT
7.31
77554.00
567,230.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
10/14.4 Providing and laying Cement concrete wearing coat M- m3 30 grade including reinforcement complete as per drawing and Technical Specifications.
17.28 198.56
5200.00 12993.00
89,856.00 2,579,891.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 13/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 14/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 15/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
46.72 46.72
4170.00 1475.00
194,823.00 68,912.00
metre
23.36
2044.00
47,748.00
Cum Cum,
28.80 14.40
12025.00 5498.00
346,320.00 79,172.00
16/14.9 Drainage Spouts complete as per drawing and Each Technical specification. 17/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing RM 18/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum
4.00
10197.00
40,788.00
70.08
160.00
11,213.00
250.75
1524.00
382,147.00
Item No.
Particulars/Descrption of items
Unit
1 2 3 19/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 20/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 21/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 22/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) Cum Cum B. Cement concrete Grade M15 23/15.11 Flexible Apron :Construction of flexible apron 1 m thick Cum comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 24/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring Cum at cross drainage works for relatively less important works
4.00
13,600.00 0.00
62.33 141.75
149.82
1679.00
251,548.00
Total- 13,419,094.00
Unit
2 2 2
m m3 3 m m3 m3
15 21 21
12.8
15.36 15 2.82 1
m3 m3 m3
13.7 m3 Total=
12.8
m/wall
2 2 2
1 1.5 1.5 3
m3 m3 m3 m3
12.40
2 2
100
kg 6114.35 kg 8710.32 kg 486.40 kg 648.89 kg 3240.00 Total = kg 19199.96 Total = Tonne 19.20
13.5
2 2 2 1 1 2
m m3 m3 m 3 m m3
3
0.2+0.45 2
Sl. Item no. No. 6 13.5 Substructure (M20) PCC Wing wallReinforcement in substuctureDirt wall 12 mm dia 12 mm dia
Abutment cap
Unit
55.84 m3
55.84
13.6
2 2 2 2 1 1 2 2 2
0.78
6 2 10 1.85
26.55 86 13.5 86
kg kg kg kg kg kg
12 12 12 12 25 12 12 25 12 12
Pier cap
10 1.85 2 100
13.5 86 100 27.3 11 100 27.3 11 100 4.06 11 1.2 4.06 11 1.2 24.36 Total = Total = 53.51
Abutment
kg kg kg
Pier=
14.1
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence on of vertical RCC post not to Painting concrete surface (Providing and applying 2 coats of water based cement paint to Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with
14.2
3.657
MT
7.31
10
14.18
12
Nos.
36.00
11
8.22
23.36
46.72
12
14.7
23.36
23.36
13
14.16
23.36
m2
3
70.08
14
14.4
8.50
23.36
198.56
15 16
14.9 13.9
2 2 12 4.00
2 2.612
Nos. m3
4 250.75
Unit
0.3
4.00
12
18
14.10
0.15
4.00
12
14.40
19
13.8
30
Nos.
30
20
8.47
Nos.
21
8.4
17.28
m2
17.28
22
15.11
141.75 m3
141.75
23
15.9
149.82 m3
149.82
24 25
15.10
1 2
62.33 23.36
m3 m
62.33 46.72
Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
380.1336 490.875
60 47
22808.02 23071.13
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-260/6, Ch-259870 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
68.12 109.87
356.00 573.00
24,251.00 62,955.00
(i) upto 3m depth 3/12.8 Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 4/12.40 Reinforcement in Foundation: Supplying, fitting and
placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
Cum
215.53
54.00
11,639.00
Cum Cum
5.74 38.29
6514.00 9030.00
37,414.00 345,759.00
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications tonne 3.8 73279.00 280,586.00
5/13.5
Item No. 1
Particulars/Descrption of items
Unit 3
2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. 6/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure 7/14.1 Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 8/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 9/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cum
19.78
9169.00
181,382.00
Tonne
1.98
73343.00
145,088.00
Cum
32.76
10591.00
346,962.00
tonne
2.62
77554.00
203,254.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
37.88 18.94
4170.00 2044.00
157,960.00 38,714.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
2.00 24.00
10197.00 204.00
20,394.00 4,896.00
Each Each
4.00
3500.00 3400.00
13,600.00
Item No.
Particulars/Descrption of items
Unit 3 Each
1 2 17/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 18/16.1 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 19/16.17 Replacement of Expansion Joints complete as per
drawings.
Sqm
82.05
78.00
6,400.00
metre Sqm
17.00 92.99
3628.00 59.00
61,676.00 5,487.00
20/16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 106 b)16 mm dia re-bar fastners 25% of 106 C)20 mm dia re-bar fastners 25% of 106 d)25 mm dia re-bar fastners 25% of 106
Sqm
15.50
614.00
9,516.00
Total-
Qty for 2Lane 68.12 1.36 2.23 3.79 36.97 1.78 20.53 43.21 109.87 64.33 151.20 215.53 5.74 5.74 38.29 38.29 3829.00 3829.00 3.8 18.207 1.58 19.78 1978.20 1978.20 1.98 32.76 32.76 2620.80 2620.80 2.62 2.00
34.06 11 15.915 18.94 3.95 3.95 3.95 3.95 Total= 3.5 4.0 Total= 0.15 Total= 3.5 Total= 100 Total= Total= 3.06 0.90 Total= 100 Total= Total= 0.9 Total= 80 Total= Total= 2
Cm Cm Cm Cm Cm Cm Cm Cm Cm
1 1.68 5.4
12.1
Earth work in or foundation of structures as per drawings & technical specification including setting out.(Upto 3m)PCC M15RCC M35 (open foundation)-
m m3 m3 m3
3 4 5
12.8 12.8
10.94 10.94
3.5 1 38.29
kg kg
Tonne
13.5
Substructure(M35)-
2 2
0.7+1.0 2
0.25
13.6
Reinforcement in Substructure-
m m3 Kg Kg
Tonne
8 9
14.1 14.2
3.5
10.4 32.76
m3 m3 Kg Kg
Tonne
10
11
12
Drainage Spouts complete as per drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
14.9
Nos.
2 2 2 2
2 11.5
12 12 12 12 0.3
Unit
2 11.5
0.3
m3
14
18.94
18.94
15
18.94
37.88
16
7.5
10.94
Sqm
82.05
17
8.5
metre
17.00
18
8.5
10.94
metre
92.99
19
12
Nos.
24.00
20
8.47
Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.
Nos.
4.00
21
8.51
12
Nos.
12.00
Unit 0.9
2
2
0.7+1.0 2
0.9
Total- sqm
23
16.53
Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
63.6 0.6
Each
15.50 106
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing Br no : 260/6, Ch-259870 m
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Cum Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 Cum H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Cum
795.80
54.00
42,974.00
77.08 245.78
6514.00 9030.00
502,122.00 2,219,349.00
3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Cum Pump 5/13.6 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
28.34
73279.00
2,076,731.00
84.62
8120.00
687,115.00
75.84
9169.00
695,368.00
Item No. 1
Total Rate in Quantity Rs. 2 3 4 5 (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne 14.75 73343.00 of Fe-500 N/mm2 Super Structure Particulars/Descrption of items Unit
in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification.
Cum
106.40
10591.00
1,126,883.00
MT
7.05
77554.00
546,524.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
(iv)'Providing and filling joint sealing compound as per metre drawings and technical specifications with coarse sand and 6% bitumen by weight. 9/8.4
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
24.00
17.00
408.00
9/14.4
Providing and laying Cement concrete wearing coat M-30 m3 grade including reinforcement complete as per drawing and Technical Specifications.
17.28 160.99
5200.00 12993.00
89,856.00 2,091,744.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I)
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
37.88 37.88
4170.00 1475.00
157,960.00 55,873.00
12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification Cum a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical Each specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. RM
18.94
2044.00
38,714.00
56.82
160.00
9,092.00
(A) Granular material Cum 18/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification
438.72 30.00
1524.00 204.00
668,610.00 6,120.00
Item No.
Particulars/Descrption of items
Unit
1 2 3 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 20/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
21/15.10 Curtain wall complete as per drawing and Technical
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
4.00
13,600.00 0.00
specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
57.78 130.54
Cum
131.06
1679.00
220,050.00
Total- 13,458,783.00
Unit
2 2
2 19.34+10.94
2
m m3 3 m m3 m3 m3 3 m m3 Total =
15 19.34 19.34
12.8
10.94 15 4.2 1
m3 m3 m3 m3 Total= m3
c/wall
12.8
m/wall
2 2 2
m3 m3 m3 m3 Total=
12.40
2 2
120 140
kg 11981.48 kg 12167.90 45.95 kg 408.44 2 kg 542.22 32.4 kg 3240.00 Total = kg 28340.05 Total = Tonne 28.34
13.5
Abutment M/wall
2 2 2 2
12 12 2.832 4.557
0.25 0.225 12 3
m m3 m3 m
3
84.62 m3
84.62
Unit
2 2 2 2
6 0.78 10 1.85 2 18 18
86
kg kg kg kg
12 12 25 12 12
mm dia mm dia
Abutment =
14.1
14.2
10
14.18
11
8.22
12
14.7
13
14.16
14
14.4
15
14.9
16
13.9
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not surface to exceed 1 Painting on concrete (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material. Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
kg 7947.53 kg 873.60 1.25 kg 4000.00 8.88 kg 888.00 Total = kg 14753.68 Total = Tonne 14.75 106.40 m3 106.40 7.047 MT 7.05
5.15
12
Nos.
24.00
18.94
37.88
18.94
18.94
18.94
m2
56.82
8.50
18.94
m3
160.99
Nos.
12
4.00
4.57
m3
438.72
17
14.11
0.3
4.00
12
m3
28.80
18
14.10
0.15
4.00
12
14.40
Unit
30
Nos.
20
8.47
Nos.
21
8.4
17.28
m2
17.28
22
15.11
130.54 m3
130.54
23
15.9
131.06 m3
131.06
24
Curtain wall complete as per drawing and Technical specification. 25 Analysis HAND RAIL rate Providing and fixing hand rail over
15.10
57.78
m3 m
57.78
18.94
37.88
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-264/1, Ch-263570 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
68.24 99.63
356.00 573.00
24,294.00 57,091.00
3/12.8
(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
195.25
54.00
10,544.00
Cum Cum
5.22 34.79
6514.00 9030.00
33,994.00 314,154.00
4/12.40
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications
tonne
3.5
73279.00
254,938.00
Item No. 1
Particulars/Descrption of items
Unit
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
6/13.6
7/14.1
2 3 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and Cum concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
20.18
9169.00
185,008.00
2.02
73343.00
147,985.00
Cum
26.98
10591.00
285,724.00
8/14.2
tonne
2.16
77554.00
167,381.00
9/14.18
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
B. M 40 grade concrete Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete per approved drawings 12/14.11 Reinforced cement as concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 11/14.7
metre metre
35.88 17.94
4170.00 2044.00
149,620.00 36,670.00
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
2.00 20.00
10197.00 204.00
20,394.00 4,080.00
Each Each
4.00
3500.00 3400.00
13,600.00
Particulars/Descrption of items 2 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.
Unit 3 Each
18/16.1
Sqm
74.55
78.00
5,815.00
19/16.17 Replacement of Expansion Joints complete as per Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 99 b)16 mm dia re-bar fastners 25% of 99 C)20 mm dia re-bar fastners 25% of 99 d)25 mm dia re-bar fastners 25% of 99 20/16.2
metre Sqm
17.00 84.49
3628.00 59.00
61,676.00 4,985.00
Sqm
24.12
614.00
14,808.00
Total-
Unit
Qty for 2Lane 68.24 1.24 2.33 3.59 30.45 1.62 21.15 39.26 99.63 64.77 130.48
12.1
Earth work in or foundation of structures as per drawings & technical specification including setting out.(Upto 3m)-
3 4 5
12.8 12.8
9.94 9.94
Total= 0.15 Total= 1 Total= 100 Total= Total= 3.15 0.82 Total= 100 Total= Total= 0.82 Total= 80 Total= Total= 2 12 12 12 12 0.3
m3 m3
kg kg
Tonne
13.5
Substructure(M35)-
2 2
0.7+1.0 2
0.25
195.25 5.22 5.22 34.79 34.79 3479.00 3479.00 3.48 18.74 1.44 20.18 2017.70 2017.70 2.02 26.98 26.98 2158.24 2158.24 2.16 2.00 24.00 24.00 24.00 24.00 27.60
13.6
Reinforcement in Substructure-
m3 m3 Kg Kg
Tonne
8 9
14.1 14.2
3.5
9.4 26.978
m3 3 m Kg Kg
Tonne
10 11
12
14.9 Drainage Spouts complete as per drawing and Technical specification. 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. 14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification
1 2 2 2 2
2 11.5
Unit
2 11.5
0.3
14
14.7
17.94 m
17.94
15
8.22
17.94 m
35.88
16
17 18
Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.) 16.17 Replacement of Expansion Joints complete as per drawings. 16.2 Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.
16.1
7.5
9.94
74.55
2 8.5
17.00 84.49
19
13.8
Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P.Solar India Ltd. Of size (125mmx125mm) ,90mm height (from bottom of shank to the top of stud) with detachable battery. RPM: Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification.
10
Nos.
20.00
20
8.47
Nos.
4.00
21
8.51
10
Nos.
10.00
Unit 0.82
2
2
0.7+1.0 2
0.82
23
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
24.12 99
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing Br no- 264/1,Ch-263570 m
Item No. 1 Foundation 1/12.1 Excavation for Structures (Earth work in excavation of
foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35
Cum
745.97
54.00
40,283.00
Cum Cum
56.69 459.36
6514.00 9030.00
369,253.00 4,148,021.00
(II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications.
4/13.5
(A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Cum Cum
17.02
73279.00
1,247,001.00
84.89
8120.00
689,307.00
77.28
9169.00
708,595.00
Particulars/Descrption of items 2 Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 Super Structure 6/14.1 Furnishing and Placing
Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
14.62
73343.00
1,072,026.00
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)
Cum
87.14
10591.00
922,900.00
MT
6.08
77554.00
471,219.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
Item No. 1
Particulars/Descrption of items 2
(v) 80cmm x 45 cm rectangular
Unit 3
10/14.4 Providing and laying Cement concrete wearing coat M- m3 30 grade including reinforcement complete as per drawing and Technical Specifications. 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. metre B. M 40 grade concrete metre 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with metre 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification Cum a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material Cum Each
35.88 35.88
4170.00 1475.00
149,620.00 52,923.00
17.94
2044.00
36,670.00
28.80 14.40
12025.00 5498.00
346,320.00 79,172.00
2.00
10197.00
20,394.00
RM
53.82
160.00
8,612.00
381.12
1524.00
580,827.00
Item No.
Particulars/Descrption of items
Unit 3 Each
1 2 18/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work 21/15.10 Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
4.00
13,600.00 0.00
54.67 124.34
Cum
121.20
1679.00
203,495.00
Total- 13,870,175.00
2 2
m3 3 m 3 m m3 m3 3 m m m3 Total =
3
18.42 18.42
12.8
m3 m3 m3 m3 Total=
15 c/wall
12.8
m/wall
2 2 2
12 0.25 0.25 30
m3 m3 m3 m3 Total=
12.40
2 2
100 80
12.94 15 100
13.5
Abutment M/wall
2 2 2 2
0.25 12 2.925 3
12 0.225 12 4.57
m m3 3 m m
3
Total= 6 13.5 Substructure (M20) PCC Wing wallReinforcement in substuctureDirt wall 12 mm dia 12 mm dia
84.89 m3
84.89
13.6
2 2
6 0.95
26.55 2
86
kg kg
283.20 290.49
Unit Qty for 2Lane 12 12 25 12 12 mm dia mm dia mm dia mm dia mm dia 2 2 2 2 2 M/wall 10 1.85 2 20 100 13.5 86 100 27.3 20 100 5.25 kg kg 240.00 282.84
Abutment
kg 8101.85 kg 970.67 1 kg 3555.56 8.92 kg 892.00 Total = kg 14616.61 Total = Tonne 14.62 87.14 m3 87.14
14.1
14.2
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material.
6.076
MT
6.08
10
14.18
12
Nos.
24.00
11
8.22
17.94
35.88
12
14.7
17.94
17.94
13
14.16
17.94
m2
53.82
14
14.4
8.50
17.94
152.49
15 16
14.9 13.9
1 2 12 4.00
2 3.97
Nos. m
3
2 381.12
28.80
18
14.10
PCC M15 grade levelling course below approach slab complete as per drawing and technical specification Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall.
0.15
4.00
12
14.40
19
13.8
40
Nos.
40
20
8.47
Nos.
21
8.4
17.28
m2
17.28
22
15.11
124.34 m3
124.34
23
24 25
Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. 15.10 Curtain wall complete as per drawing and Technical specification. Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
15.9
121.20 m3
121.20
1 2
54.67 17.94
m3 m
54.67 35.88
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-264/2 , Ch-263955 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
61.72 87.77
356.00 573.00
21,973.00 50,294.00
3/12.8
(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
181.25
54.00
9,788.00
Cum Cum
5.22 32.70
6514.00 9030.00
33,994.00 295,305.00
4/12.40
Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m
tonne
3.27
73279.00
239,623.00
Item No. 1
Particulars/Descrption of items 2 Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
Unit 3 Cum
6/13.6
7/14.1
8/14.2
9/14.18
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in metre expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board metre in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick metre premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. metre
1.16
73343.00
85,078.00
26.98
10591.00
285,724.00
2.16
77554.00
167,381.00
24.00
1640.00
39,360.00
24.00
558.00
13,392.00
24.00
317.00
7,608.00
24.00
17.00
408.00
Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
B. M 40 grade concrete metre Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar Cum 13/14.10 PCC M15 grade levelling course below approach slab Cum complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical Each specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced Each concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud Each b) Uni-directional Stud Each 17/8.51 Providing relfective pavement marker with Micro Each prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. 11/14.7
35.88 17.94
4170.00 2044.00
149,620.00 36,670.00
4.00 10.00
13,600.00 2,980.00
Particulars/Descrption of items 2 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
Unit 3 Sqm
19/16.17 Replacement of Expansion Joints complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 90 b)16 mm dia re-bar fastners 25% of 90 C)20 mm dia re-bar fastners 25% of 90 d)25 mm dia re-bar fastners 25% of 90 20/16.2
metre Sqm
17.00 84.49
3628.00 59.00
61,676.00 4,985.00
Sqm
11.46
614.00
7,039.00
Unit
Qty for 2-Lane 61.72 1.24 2.09 3.59 30.45 1.62 11.89 36.91 87.77 64.77 116.48 181.25 5.22 5.22 32.70 32.70 3270.00 3270.00 3.27 10.17 1.44 11.60 1160.00 1160.00 1.16 26.98 26.98 2158.24 2158.24 2.16 2.00
Cm Cm Cm Cm Cm Cm Cm
2 2
0.275 2 2 1 2 2
9.94
9.95 3.5
3.5 4.16
Total= m3 9.94 3.5 0.15 m3 Total= 0.94 Total= 100 kg Total= kg Total= Tonne 1.771 0.82 m3 Total= m3 100 Kg Total= Kg Total= Tonne 0.82 m3 Total= m3 80 Total= Total= 2 Kg Kg
Tonne
9.94
3.5
32.7
13.5 Substructure(M35)-
2 2
0.7+0.94 2 0.25
3.5 3.5
11.6
3.5
9.4
26.978
10
Nos.
per drawing and Technical specification. 11 14.18 Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
2 2 2 2
12 12 12 12
Unit
2 11.5
0.3
m3
13 14.11
11.5
0.3
m3
27.60
14
14.7
17.94
17.94
15
8.22
17.94
35.88
16
16.1
7.5
9.94
74.55
17 16.17
8.5
17.00
18
16.2
8.5
9.94
metre
84.49
19
13.8
10
Nos.
20.00
20
8.47
Nos.
4.00
Unit 10 Nos.
0.82
2
2
0.7+0.94 2
0.82
Total- sqm
23
16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers.
11.46 90
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing Br no: 264/2, Ch-263955
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
Cum
589.44
54.00
31,830.00
Cum Cum
49.21 167.76
6514.00 9030.00
320,561.00 1,514,873.00
3/12.40
tonne
14.06
73279.00
1,030,430.00
4/13.5
Cum
55.40
8120.00
449,848.00
Cum
46.09
9169.00
422,585.00
5/13.6
Item No. 1
Particulars/Descrption of items 2 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Tonne
8.57
73343.00
628,830.00
6/14.1
7/14.2
8/14.18
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
Cum
87.14
10591.00
922,900.00
MT
6.08
77554.00
471,219.00
metre
20.00
1640.00
32,800.00
metre
20.00
558.00
11,160.00
metre
20.00
317.00
6,340.00
metre
20.00
17.00
340.00
9/8.4
10/14.4
Providing and laying Cement concrete wearing coat m3 M-30 grade including reinforcement complete as per drawing and Technical Specifications.
17.28 152.49
5200.00 12993.00
89,856.00 1,981,303.00
Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
B. M 40 grade concrete 11/Analysi HAND RAIL s Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
metre metre
35.88 35.88
4170.00 1475.00
149,620.00 52,923.00
metre
17.94
2044.00
36,670.00
13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material
Cum Cum,
28.80 14.40
12025.00 5498.00
346,320.00 79,172.00
Each
2.00
10197.00
20,394.00
RM
53.82
160.00
8,612.00
Cum
248.64
1524.00
378,928.00
Particulars/Descrption of items 2 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Unit 3 Each
19/8.47
20/8.51
4.00
13,600.00 0.00
Protection work Curtain wall complete as per drawing and Technical specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
21/15.10
45.94 104.49
Cum
98.78
1679.00
165,852.00
Total-
9,653,988.00
Qty for 2Lane 251.68 7.46 9.00 104.49 67.10 31.69 71.60 46.44 589.44
2 2
15.48+9.94 2
m3 3 m m3 3 m m3 m3
15.48 15.48
2.5 m3 3 2 m Total = m3
12.8
0.15 0.15
m3 3 m
15
9.94 m3 Total= m3
12.8
m/wall
2 2 2
12 0.25 0.25 3
m3 m3 m3 3 m m3
12.40
2 2
110 80
12.94 15 100
13.5
Abutment M/wall
2 2 2 2
0.25 12 12 3
m3 m3 m3 m
3
13.5
Substructure (M20) PCC Wing wall Reinforcement in substucture Dirt wall 12 mm dia 12 mm dia
55.4 m3
55.40
13.6
2 2
6 0.95
26.55 2
86
kg kg
283.20 290.49
Sl. No.
Abutment cap
Unit
Qty for 2Lane 241.78 282.84 4205.53 533.87 2151.11 585.00 8573.82 8.57 87.14
12 12 20 12 12
2 2 2 2 2 M/wall=
Abutment
14.1
14.2
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. Filler joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material.
6.076
MT
6.08
10
14.18
10
Nos.
20.00
11
8.22
17.94
35.88
12
14.7
17.94
17.94
13
14.16
17.94
m2
53.82
14
14.4
8.50
17.94
152.49
15 16
14.9 13.9
1 2 12 4.00
2 2.59
Nos. m
3
2 248.64
Sl. No. 17
Unit 14.11
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. PCC M15 grade levelling course below approach slab complete as per drawing and technical specification. Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3 Stone apron Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works.
0.3
4.00
12
m3
18
14.10
0.15
4.00
12
m3 Nos.
14.40
19
13.8
40
40
20
8.47
Nos.
21
8.4
17.28
m2
17.28
22
15.11
104.49 m3
104.49
23
15.9
98.78
m3
98.78
24 25
Curtain wall complete as per drawing and Technical specification. Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
15.10
1 2
45.94 17.94
m3 m
45.94 35.88
2 2 1.85 86 318.2
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-265/1, Ch-264876 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation 2/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantit y 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
60.52 96.94
356.00 573.00
21,546.00 55,549.00
3/12.8
(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
232.42
54.00
12,551.00
Cum Cum
5.22 34.79
6514.00 9030.00
33,994.00 314,154.00
4/12.40
Reinforcement in Foundation: Supplying, fitting and placing uncoated TMT bar reinforcement in foundation complete as per drawing and technical specifications
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35
tonne
3.48
73279.00
254,938.00
Item No. 1
Particulars/Descrption of items
Unit
6/13.6
7/14.1
2 3 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Cum Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Cum Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in metre expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board metre in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded metre joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. metre
1.74
73343.00
127,434.00
26.98
10591.00
285,724.00
8/14.2
2.16
77554.00
167,381.00
9/14.18
24.00
1640.00
39,360.00
24.00
558.00
13,392.00
24.00
317.00
7,608.00
24.00
17.00
408.00
Particulars/Descrption of items 2 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.
Unit 3
Total Quantit y 4
Rate in Rs. 5
Amount (Rs.) 6
B. M 40 grade concrete Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 11/14.7 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
metre metre
35.88 17.94
4170.00 2044.00
149,620.00 36,670.00
17/8.51
4.00 11.00
13,600.00 3,278.00
Particulars/Descrption of items 2 Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
Unit 3 Sqm
19/16.17 Replacement of Expansion Joints complete as per drawings. Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 99 b)16 mm dia re-bar fastners 25% of 99 C)20 mm dia re-bar fastners 25% of 99 d)25 mm dia re-bar fastners 25% of 99 20/16.2
metre Sqm
17.00 84.49
3628.00 59.00
61,676.00 4,985.00
Sqm
13.62
614.00
8,363.00
Unit
Qty for 2Lane 60.52 1.24 2.09 3.59 30.45 0.34 19.98 39.26 96.94 134.42 98.00 232.42 5.22 5.22 34.79 34.79 3479.00 3479.00 3.48 15.94 1.44 17.37 1737.50 1737.50 1.74 26.98 26.98 2158.24 2158.24 2.16 2.00
Cm Cm Cm Cm Cm Cm Cm
9.95 3.5
3.5 3.5
Total= m3 3 12.8 PCC M159.94 3.5 0.15 m3 Total= 1 Total= 100 kg Total= kg Total= Tonne 2.976 0.82 m3 Total= m3 100 Kg Total= Kg Total= Tonne 0.82 m3 Total= m3 80 Kg Total= Kg Total= Tonne 2 12 12 12 12 Nos. Nos. Nos. Nos. Nos.
9.94
3.5
34.79
13.5 Substructure(M35)-
2 2
0.7+1.0 2 0.25
3.15 3.5
17.375
3.5
9.4
26.978
10 11
1 2 2 2 2
Unit
2 11.5
0.3
m3
13
11.5
0.3
m3
27.60
14
17.94
17.94
15
17.94
35.88
16
7.5
9.94
74.55
17 18
2 8.5
17.00
84.49
19
10
Nos.
20.00
20
Nos.
4.00
21
8.51
11
Nos.
11.00
Unit 0.82
2
2
0.7+1.0 2
0.82
23
13.62 99
2400 0.3479
100 2748.41
24
280
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for existing Br no-265/1 , Ch-264876
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
589.78
54.00
31,849.00
Cum Cum
55.54 160.26
6514.00 9030.00
361,780.00 1,447,148.00
3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar tonne of Fe-500 N/mm2 Substructure 4/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m Cum H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel Cum
17.02
73279.00
1,247,001.00
84.89
8120.00
689,307.00
73.38
9169.00
672,830.00
5/13.6
Item No. 1
Particulars/Descrption of items
Unit
2 3 (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 Super Structure
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
6/14.1
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m 7/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
Cum
87.14
10591.00
922,900.00
MT
6.08
77554.00
471,219.00
metre
24.00
1640.00
39,360.00
metre
24.00
558.00
13,392.00
metre
24.00
317.00
7,608.00
metre
24.00
17.00
408.00
10/14.4 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.
17.28 152.49
5200.00 12993.00
89,856.00 1,981,303.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 11/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 12/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I)
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
metre metre
35.88 35.88
4170.00 1475.00
149,620.00 52,923.00
12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 metre mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification Cum a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab Cum, complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical Each specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 18/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification Cum Each RM
17.94
2044.00
36,670.00
53.82
160.00
8,612.00
364.42 40.00
1524.00 204.00
555,370.00 8,160.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
21/15.10 Curtain wall complete as per drawing and Technical
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
4.00
13,600.00 0.00
specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
53.42 121.50
Cum
117.76
1679.00
197,720.00
Total- 10,937,884.00
Unit
Qty for 2Lane 196.81 7.46 9.00 121.50 67.10 50.67 83.25 54.00 589.78
2 2
18+9.94 2
m3 3 m m3 m3 3 m m3
18 18
2.5 m3 3 2 m Total =
12.8
m m3 m3 Total=
15
12.8
m/wall
2 2 2
12 0.25 0.25 3
m3 m3 m3 m3 Total=
2 2
100 80
12.94 15 100
13.5
Abutment M/wall
2 2 2 2
0.25 12 2.751 3
12 0.225 12 4.39
m3 m3 m3 m3
Total= m3 6 13.5 Substructure (M20) PCC Wing wallReinforcement in substuctureDirt wall 12 mm dia 12 mm dia
84.89 m3
84.89
13.6
2 2
6 0.95
26.55 2
86
kg kg
283.20 290.49
Sl. No .
Item no.
Abutment cap
Unit 12 12 25 12 12 mm dia mm dia 2 2 10 1.85 13.5 86 100 27.3 20 100 4.076 1 8.56 kg kg
Abutment
14.1
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification.
87.14
14.2
6.076
MT
6.08
10
12
Nos.
24.00
11
8.22
17.94
35.88
12
13
14
Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing 14.4 Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.
14.7
17.94
17.94
17.94
53.82
8.50
17.94
m3
152.49
15 16
14.9 13.9
Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material.
1 2 12 4.00
2 3.796
Nos. m3
2 364.416
Sl. No . 17
18
0.15
4.00
12
m3
14.40
19
13.8
20
8.47
Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, Providing 'Sparkle Solar Road Studs,manufactured by Tata B.P. Solar India Ltd. Of siz(125mmx125mm),90mm height(frombottom of shank to the top of stud)with detachable battery. Sign board : Retro reflectorised Traffic sign: Providing and erecting of RetroReflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3
40
Nos.
40
Nos.
21
8.4
17.28
m2
17.28
22
121.5
m3
121.50
:Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23 15.9 Flore apron :Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works. 24 15.10 Curtain wall complete as per drawing and Technical specification. 25 Analysis HAND RAIL rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc.
117.76 m3
117.76
1 2
53.424 m3 17.94 m
53.42 35.88
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt for Repairing of existing Br no-266/1 ,Ch-265310 m
Item No. 1 1/2.4 Particulars/Descrption of items 2 Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) II) By Mechanical Means (a) Cement concrete grade M-15 & M-20 Wing wall(b) Prestressed/ Reinforced cement grade M-20 & above. Foundation
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Unit 3
Total Quantit y 4
Rate in Rs. 5
Amount (Rs.) 6
Cm Cm
61.32 101.20
356.00 573.00
21,830.00 57,990.00
2/12.1
3/12.8
(i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork. (p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump
Cum
212.73
54.00
11,488.00
Cum Cum
8.57 53.76
6514.00 9030.00
55,851.00 485,453.00
4/12.40
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications
5/13.5
(a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) tonne reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications
5.38
73279.00
393,948.00
Item No. 1
Particulars/Descrption of items 2 (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump. Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Super Structure Furnished and placing reinforcement/Prestressed cement concrete in superstructure as per drawing and Technical Specifications. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B. RCC GRADE M 25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight.
Unit 3
Total Quantit y 4
Rate in Rs. 5
Amount (Rs.) 6
Cum
30.44
9169.00
279,123.00
6/13.6
Tonne
3.04
73343.00
223,183.00
7/14.1
Cum
33.67
10591.00
356,599.00
8/14.2
tonne
2.69
77554.00
208,900.00
9/14.18
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
Particulars/Descrption of items
Unit
11/14.7
2 3 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre Construction of RCC railing of M30 Grade in-situ with metre 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
Total Quantit y 4
Rate in Rs. 5
Amount (Rs.) 6
46.72 23.36
4170.00 2044.00
194,823.00 47,748.00
12/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 13/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 14/14.9 Drainage Spouts complete as per drawing and Technical specification 15/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 16/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud
Cum Cum
27.60 27.60
12025.00 5498.00
331,890.00 151,745.00
Each Each
4.00 24.00
10197.00 204.00
40,788.00 4,896.00
Each Each
4.00
3500.00 3400.00
13,600.00
Particulars/Descrption of items 2 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000.(Thickness 75mm.)
drawings.
Unit 3 Each
18/16.1
Sqm
115.20
78.00
8,986.00
19/16.17 Replacement of Expansion Joints complete as per metre Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m. 21/16.28 (A)'Supplying and applying Epoxy based bonding agent Masterbond EP of Choksey Chemicals or euivalent @ 0.50 Lit pe sqm after totally saturating the 22/16.53 Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers. a)12 mm dia re-bar fastners 25% of 187 b)16 mm dia re-bar fastners 25% of 187 C)20 mm dia re-bar fastners 25% of 187 d)25 mm dia re-bar fastners 25% of 187 20/16.2 Sqm
25.50 130.56
3628.00 59.00
92,514.00 7,704.00
Sqm
32.06
614.00
19,684.00
Total-
Unit
Cm Cm Cm Cm Cm Cm Cm
61.32 1.61 2.77 4.67 30.45 1.62 20.82 39.26 101.20 106.33 106.40 212.73 8.57 8.57 53.76 53.76 5376.00 5376.00 5.4 18.45 10.85 1.14 30.44 3043.00 3043.00 3.04 33.67 33.67 2693.60 2693.60 2.69 4.00 36.00 36.00 36.00 36.00 27.60
15.5 3.5
3.5 3.8
1 Cm Total= Cm 1.96 m3 4.0 m3 Total= 0.15 Total= 1 Total= 100 Total= Total= 3.101 3.101 0.250 Total= 100 Total= Total= 0.65 Total= 80 Total= Total= 2 12 12 12 12 0.3 m3 m3 Kg Kg
Tonne
3 4 5
15.66 15.36
m3 m3
kg kg
Tonne
13.5
Substructure(M35)-
2 2
8 9
14.1
3.5
7.4 33.67
m3 m3 Kg Kg
Tonne
10 11
2 3 3 3 3
2 11.5
12
Unit
0.3
14
14.7
23.36
23.36
15
23.36
46.72
16
7.5
15.36
115.20
17 18
3 8.5
25.50 130.56
19
12
Nos.
24.00
20
Nos.
4.00
Unit
15
Nos.
22
2
2
0.65
0.7+1.0 2
1 1
23
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing Br no-266/1, Ch-265310
Item No. 1 Foundation 1/12.1
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Particulars/Descrption of items 2
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2/12.8
I. Ordinary Soil B. Mechanical means (II) With dewatering (i) upto 3m depth Plain/Reinforced Cement concrete, in open Foundation complete as per Drawing and Technical Specifications including steel shuttering formwork.
Cum
1017.62
54.00
54,952.00
(p) With plasticser (Master plast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. A.PCC Grade M15 H.RCC Grade M35 (II) Using Batching plant Transit mixer and concrete pump 3/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications. (A) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Substructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (P)With plasticiser (Masterplast PL-1/SPL-2 or equivalent),air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 B. PCC Grade M20 a) Height up to 5.0 m H. RCC Grade M 35 a) Height up to 5.0 m Case II : With Batching plant, Transit Mixer and concrete Pump Supplying, fitting and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications
Cum Cum
98.86 528.42
6514.00 9030.00
643,976.00 4,771,633.00
tonne
28.27
73279.00
2,071,656.00
4/13.5
Cum
80.22
8120.00
651,387.00
Cum
137.50
9169.00
1,260,740.00
5/13.6
Item No. 1
Particulars/Descrption of items 2 (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel reinforcement bar of Fe-500 N/mm2 Super Structure (CRS)
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Tonne
17.96
73343.00
1,317,314.00
6/14.1
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork.
7/14.2
(P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B.'RCC Grade M25 Case II : Using Batching Plant, Transit Mixer and Concrete Pump ii) For T-Beam and Slab a) Height up to 5.0 m Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
Cum
107.02
10591.00
1,133,449.00
(i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 8/14.18 Filler joint (i)'Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. ii) 'Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. (iii)'Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specification. (iv)'Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight. Retro reflectorised Traffic sign: 9/8.4
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
MT
7.31
77554.00
567,230.00
metre
36.00
1640.00
59,040.00
metre
36.00
558.00
20,088.00
metre
36.00
317.00
11,412.00
metre
36.00
17.00
612.00
17.28
5200.00
89,856.00
Particulars/Descrption of items
Unit
2 3 Providing and laying Cement concrete wearing m3 coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.
10/8.22 Reinforced Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete 11/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I) 12/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 13/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification a) With TATA make TMT CRS (Fe-500) grade rebar 14/14.10 PCC M15 grade levelling course below approach slab complete as per drawing and technical specification 15/14.9 Drainage Spouts complete as per drawing and Technical specification. 16/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) (B) For RCC Railing metre 46.72 4170.00 194,823.00
metre
46.72
1475.00
68,912.00
metre
23.36
2044.00
47,748.00
Cum Cum,
28.80 14.40
12025.00 5498.00
346,320.00 79,172.00
Each
4.00
10197.00
40,788.00
RM
70.08
160.00
11,213.00
Item No.
Particulars/Descrption of items
Unit 3
1 2 17/13.9 Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification. (A) Granular material 18/13.8 Providing weep holes in brick mansonry/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of IV:20H towards drawing foce, complete as per drawing and technical specification 19/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Stud b) Uni-directional Stud 20/8.51 Providing relfective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. Protection work
21/15.10 Curtain wall complete as per drawing and Technical
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
Cum Each
360.10 30.00
1524.00 204.00
548,787.00 6,120.00
4.00
13,600.00 0.00
specification A. Stone masonry in cement mortar (1:3) B. Cement concrete Grade M15 22/15.11 Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. 23/15.9 Dry rubble Flooring, Construcytion of dry rubbl flooring at cross drainage works for relatively less important works
69.09 157.14
Cum
172.53
1679.00
289,678.00
Total-
17,600,559.00
Unit
Qty for 2Lane 490.29 11.52 8.63 157.14 68.86 103.68 107.67 69.84 1017.62
2 2 2
m3 m3 m3 3 m 3 m m 3 m m3 m3
3
23.28 23.28
12.8
PCC M-15 12
15.36
2 c/wall
23.28+15.36 2
15.36 15 3.96 1
m m3 m3
13.7 m3 Total= m3
12.8
2 2 2
12 0.25 0.25 12
1 1.5 1.5 3
m3 m3 m3 m3 m3
2 2
60 104 10 365
kg 15185.19 kg 8710.32 kg 486.40 kg 648.89 32.4 kg 3240.00 Total = kg 28270.80 Total = Tonne 28.27 0.25 0.225 12 1 1 4.351 m3 3 m 3 m m m3 3 m Total=
3
13.5
2 2 2 1 1 2
12 12 2.876 12 2.876 12
3.90 3.78 58.67 2.70 34.51 33.94 137.50 80.22 283.20 238.51 240.00
6 7
13.5 13.6
80.22 m3 kg kg kg
86
12
mm dia
Sl. No.
Item no. 12 Pier cap 12 12 25 12 12 mm dia mm dia mm dia mm dia 2 mm dia 2 mm dia 2 M/wall= 2 1.85 1 1 2 27.3 20 86 10 1.85 100 20 100 100 13.50 86.00 5.2
Unit kg kg kg
Qty for 2Lane 282.84 120.00 141.42 8024.69 970.67 4266.67 3393.00 17961.00 17.96 107.02
Abutment
14.1
Furnished and placing reinforcement/Prestressed cement concrete in Superstructure M25 as per drawing and Technical Specifications. Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specification. compressible fibre board in expansion joint complete as per drawing & Technical Specification.
14.2
3.657
MT
7.31
10
12
Nos.
36.00
11
12
13
Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road,approaches to bridge structures and medians, constructed with M-20 grade concrete. 14.7 Construction of RCC Railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm. 14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered For RCC Railing
8.22
23.36
46.72
23.36
23.36
23.36
m2
70.08
14
14.4
Providing and laying Cement concrete Wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. Drainage Spouts complete as per drawing and Technical specification. Back filling behind Abutment ,Wing wall and Return Wall complete as per drawing and technical specification with Granular Material.
8.50
23.36
m3
198.56
15 16
14.9 13.9
2 2 12 4.00
2 3.751
Nos. m3
4 360.096
17
0.3
4.00
12
28.80
18
0.15
4.00
12
m3
14.40
Sl. No. 19
Unit 1 30 Nos.
20
8.47
Nos.
21
8.4
17.28
17.28
22
15.11
157.14 m3
157.14
23
15.9
172.53 m3
172.53
24
15.10
1 2
69.09 23.36
m3 m
69.09 46.72
25 Analysi
s rate
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing br no- 226/1 Ch-225454
Item No. 1
1/12.9
Unit 3
Amount (Rs.) 6
Providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. Well. (A) 'Assuming depth of water 1.0 m and height of island to Each be 1.25m. (c)'Providing and constructing one span service road to reach island location from one pier location to another pier metre location 2/12.10 Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per Tonne drawing and technical specification. 3/12.11 Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. (A) 'Well curb
4.00 108.00
57977.00 2472.00
231,908.00 266,976.00
54.43
101302.00
5,514,071.00
907.20
10003.00
9,074,722.00
11875.22
9169.00 108,883,895.00
1631.84
8924.00
14,562,541.00
105.56
8133.00
858,520.00
1233.84
9030.00
11,141,576.00
Item No. 1
Particulars/Descrption of items 2
Unit 3
Amount (Rs.) 6
6/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement tonne bar of Fe-500 N/mm2 Subsructure 7/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999 (H) 'RCC Grade M35 Case-II : 'With Batching Plant, Transit Mixer and Concrete Cum Pump 8/13.6 Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2 9/13.12 Supplying, fitting and fixing in position true to line and level forged steel roller bearing conforming to IRC: 83(Pt.tonne 1) section IX and clause 2003 of MoRTH specifications capacity complete including all accessories as per drawing and Technical Specifications. 10/13.11 Supplying, fitting and fixing in position true to line and level cast steel rocker bearing conforming to IRC: 83(Pt.tonne 1) section IX and clause 2003 of MoRTH specifications capacity complete including all accessories as per drawing and Technical Specifications. Superstructure 11/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-91031999. (E) 'PSC Grade M-40 Case II : 'Using Batching Plant, Transit Mixer and Concrete Pump (ii) 'For T-beam & slab (a) Height upto 5m Cum 12/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2
816.90
73279.00
59,861,527.00
507.68
9169.00
4,654,955.00
139.85
73343.00
10,256,799.00
4200.00
1191.00
5,002,200.00
4200.00
953.00
4,002,600.00
2748.00
10920.00
30,008,160.00
351.78
77554.00
27,281,947.00
Item No. 1
Particulars/Descrption of items 2
Unit 3
13/14.3 High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete Tonne as per drawing and Technical Specifications 14/14.5 Mastic Asphalt (A) Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.
sqm
2215.44
329.00
728,880.00
15/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to metre exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 16/14.22 Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the metre manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation). 17/8.22 Reinforced Cement Concrete Crash
521.28
2044.00
1,065,497.00
84.00
11804.00
991,536.00
Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre
18/13.9 Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification (A) 'Granular material 19/13.8 Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification. 20/14.9 Drainage Spouts complete as per drawing and Technical specification 21/14.10 leveling course below approach slab complete as per drawing and Technical specification' (PCC M15 Grade)
521.28
4170.00
2,173,738.00
Cum
954.72
1524.00
1,454,994.00
Each
40.00
204.00
8,160.00
Each Cum
24.00 28.80
10197.00 5498.00
244,728.00 158,343.00
Item No. 1
Particulars/Descrption of items 2
Unit 3
Amount (Rs.) 6
22/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification (A) With TATA make TMT CRS (Fe-500) grade rebar 23/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) (B) For RCC Railing 24/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Studb) Uni-directional Stud25/8.51 Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&Hs fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Cum
28.80
12025.00
346,320.00
RM
781.92
160.00
125,108.00
Each Each
4.00
3500.00 3400.00
13,600.00
Each
100.00
298.00
29,800.00
Protection work 26/15.5 Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications. Cum 27/15.4 Providing and laying pitching on slop laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . a) Stone/Boulder 28/15.1 Providing nad laying boulder apron on river bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical specifications. Cum 3294.180 1463.00 4819386.00 988.25 1862.00 1840122.00
Cum
4152419.00 363,487,085.00
1 (i) Temporary Island 24m dia (ii) Service Road 2 Cutting edge 3 PCC/RCC work in well foundation : a) Well curb (RCC M-35) b) Well Steining (RCC M-35) 27x/4(12- 8)x7 c) Bottom Plug (PCC M-30) d) Intermediate Plug (PCC M-30) e) Well Cap (RCC M-35)
1 18 60
4 129.60
Nos. m T
3
129.60
233.12
m3 3 m
7 2 5
m m3 m3
4 Sinking of well 0 to 3 m 3 to 10 m 10 to 20 m 20 to 30 m 5 Sand fill 7 x /4 x 8 x 26.4 6 Reinforcement in foundation (HYSD bars): Well Curb mm dia 7 8.5 12 mm dia 12 7 1.8 mm dia 20 7 28.5 Steining 32 32 12 12 32 Abutment well cap 32 32 20 20 Pier 32 28 mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia mm dia 5 5 7 7 2 2 2 2 2 5 5 230 200 135 135 170+150 120 120 120 120 120 120 32.5 32.5 32.5 2.5 32.5 8.5 9.1 9.1 8.5 8 8
7 7 7 7
3 7 10 10
m m m m
9289.06
188
188 41
2 1
Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Kg Tonne
236246.91 205432.10 54600.00 2100.00 131476.54 12894.81 13805.04 5392.59 5037.04 60681.48 46459.26 816898.79 816.90
2 2
Dirt wall Abutment Cap Return wall Abutment Pier cap Pier 8 Reinforcement in substructureDirt wall Return wall Abutment Cap Abutment 2 Pier Cap 5 Pier 5
2 2 4 2 5 5
12 1 3.27 3.57
3.86 12 4 12
27.79 5.52 31.39 107.10 135.00 200.88 507.684 4014.00 2480.00 1200.00 24758.00 45500.00 61895.00 139847.00 139.85 4200.00 4200.00 2748.00 2748.00 351.78 351.78 117.72
1.2
12
2 4 2
4 4
175 175 6
12 Reinforcement bar in super structure (TMT CRS) 6 13 Reinforcement bar in super structure (High tensile steel) 6 14 Wearing coat(Mastic Asphalt)1 15 16 17 18 19 20 21 22 23 24 25 RCC RailingStrip seal Expansion JointCrash barrier Back fill behind abutment Leveling course (M-15) (Below approach slab)Weep holes Drainage spout Apprpoach slab (M25) Painting Soler stud RPM 8.5 260.64 1 7 2 7.65 521.28 12 260.64 12 Sqm Rm M 5.2 m3 28.8 m3 Nos. Sqm 12 m3 Sqm Nos. Nos. 2215.44 521.28 84.00 521.28 954.72 28.80 34.08 40.00 24.00 28.80 781.92 4.00 100.00 19.62 T 58.63 T T
2 6 2 3
20 4 4 260.64 1
Cum 2 Providing and laying pitching on slop laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . a) Stone/Boulder
988.25
1263.00
1248159.75
Cum 3 Providing nad laying boulder apron on river bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical specifications.
3294.180
1154.00
3801483.72
Cum
3275386.66 8325030.13
2.99 6.32
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing br no- 232/1 Ch-231240
Item No. Particulars/Descrption of items 2 Foundation
1/12.9 Providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. Well.
Unit 3
Amount (Rs.) 6
(A) 'Assuming depth of water 1.0 m and height of island to Each be 1.25m. (c)'Providing and constructing one span service road to reach island location from one pier location to another pier metre location 2/12.10 Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing Tonne and technical specification. 3/12.11 Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-91031999. (A) 'Well curb
57977.00 2472.00
0.00 0.00
15.55
101302.00
1,575,449.00
Cum
259.20
10003.00
2,592,778.00
Cum
3392.92
9169.00
31,109,685.00
Cum
466.24
8924.00
4,160,726.00
Cum
30.16
8133.00
245,292.00
Cum
385.64
9030.00
3,482,330.00
metre
Item No.
6/12.40
Particulars/Descrption of items 2
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2 Subsructure Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999
Unit 3
Amount (Rs.) 6
tonne
165.72
73279.00
12,143,870.00
7/13.5
(H) 'RCC Grade M35 Case-II : 'With Batching Plant, Transit Mixer and Concrete Cum Pump 8/13.6 Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 9/13.12 Supplying, fitting and fixing in position true to line and level forged steel roller bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications tonne complete including all accessories as per drawing and capacity Technical Specifications.
10/13.11 Supplying, fitting and fixing in position true to line and level
145.01
9169.00
1,329,557.00
31.61
73343.00
2,318,619.00
776.00
1191.00
924,216.00
cast steel rocker bearing conforming to IRC: 83(Pt.-1) tonne section IX and clause 2003 of MoRTH specifications capacity complete including all accessories as per drawing and Technical Specifications.
776.00
953.00
739,528.00
Superstructure
11/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. (E) 'PSC Grade M-40 Case II : 'Using Batching Plant, Transit Mixer and Concrete Pump (ii) 'For T-beam & slab (a) Height upto 5m Cum 12/14.2 Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar Tonne of Fe-500 N/mm2 13/14.3 High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete Tonne as per drawing and Technical Specifications 14/14.5 Mastic Asphalt
510.00
10920.00
5,569,200.00
64.30
77554.00
4,986,723.00
20.70
167708.00
3,471,556.00
Item No.
Particulars/Descrption of items 2
(A) Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.
Unit 3
Amount (Rs.) 6
sqm
474.64
329.00
156,157.00
15/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to metre exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications. 16/14.22 Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the metre manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation). 17/8.4 Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)
55.48
2044.00
113,402.00
24.00
11804.00
283,296.00
Sqm Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre
8.64
5200.00
44,928.00
110.96
4170.00
462,704.00
Item No.
Particulars/Descrption of items 2
Unit 3
Amount (Rs.) 6
19/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier
consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I)
20/13.9 Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification (A) 'Granular material 21/13.8 Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification. 22/14.9 Drainage Spouts complete as per drawing and Technical specification 23/14.10 leveling course below approach slab complete as per drawing and Technical specification' (PCC M15 Grade) 24/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification (A) With TATA make TMT CRS (Fe-500) grade rebar 25/14.16 Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) (B) For RCC Railing 26/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bidirectional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a) Bi-directional Studb) Uni-directional Stud27/8.51 Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&Hs fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
metre
111.68
1475.00
164,728.00
Cum
944.05
1524.00
1,438,736.00
Each
40.00
204.00
8,160.00
Each Cum
4.00 28.80
10197.00 5498.00
40,788.00 158,343.00
Cum
28.80
12025.00
346,320.00
RM
167.52
160.00
26,804.00
Each Each
4.00
3500.00 3400.00
13,600.00
Each
60.00
298.00
17,880.00
Protection work 28/15.5 Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications.
Item No.
Particulars/Descrption of items 2
Unit 3
Amount (Rs.) 6
Cum 29/15.4 Providing and laying pitching on slop laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . a) Stone/Boulder
2134.720
1862.00
3974848.64
Cum 30/15.1 Providing nad laying boulder apron on river bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical specifications.
1642.930
1463.00
2403606.59
Cum
5911675.77 99,926,784.00
B. M 40 grade concrete
Qty for 2Lane 0.00 0.00 15552.00 15.55 259.20 3392.92 466.24
233.12
m3 3 m
2 2
m3 m3
2 2 2 2
3 7 10 10
m m m m m3
5 6
188
188 41
2 1
Kg Kg Kg Kg Kg Kg Kg Kg Kg Tonne
m3 3 m m3 m3
50330.86 44039.51 18480.00 600.00 13805.04 12894.81 6902.52 6447.41 165721.01 165.72
28.37 5.52 9.42 101.70 145.01
Sub structure (RCC M-35) Dirt wall Abutment Cap Return wall Abutment
2 2 4 2
0.3 12 4 1+1.5 2
12 1 3.27 3.39
0.3
2 4
2007 620
kg kg
4014.00 2480.00
600 6.22 6.22 9.61 23 23 97 49 48 32.1 97 6.32 6.32 6.32 0.89 0.89 TotalTotal-
1200.00 7627.41 3853.02 5831.49 1312.53 5294.91 31613.36 31.613 776.00 776.00 510.00 0.00 510.00 64.30 64.30 20.7
1.5
1 1
4 4 1
12 Reinforcement bar in super structure (TMT CRS) 1 13 HTS Stand 14 Wearing coat(Mastic Asphtl)1 15 16 17 18 19 20 21 22 23 24 25 26 27 RCC RailingStrip seal Expansion JointCrash barrier Back fill behind abutment Leveling course (M-15) (Below approach slab)Weep holes Drainage spout Apprpoach slab (M25) Painting Soler stud 8.5 55.84 1 2 2 7.55 20 4 4 55.84 1 1 2 55.48 12 55.48 12 Sqm Rm m 5.21 m3 28.8 m3 Nos. Sqm 12 m3 Sqm 4 Nos. Nos. Sqm m 474.64 55.48 24.00 110.96 944.05 28.80 40.00 4.00 28.80 167.52 4.00 60.00 8.64 111.68 1 64.3 20.7
2 2 1 2 3
0.3
60 8.64 55.84
1 2 1/15 Providing and laying filter material .5 underneath pitching in slopes complete as per drawing and technical specifications.
Cum 2/15 Providing and laying pitching on slop laid .4 over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . a) Stone/Boulder
2134.720
1862.00
3974848.64
Cum 3/15 Providing nad laying boulder apron on river .1 bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical specifications.
1642.930
1463.00
2403606.59
Cum
5911675.77 12290131
Item 1 1/15.5
Descriptions 2 Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications.
Unit 3
Estmated Quantity 4
Rate in Rs. 5
Cum 2/15.4 Providing and laying pitching on slop laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . a) Stone/Boulder
2134.720
1862.00
Cum 3/15.1 Providing nad laying boulder apron on river bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical specifications.
1642.930
1463.00
Cum
Amount in Rs 6
3974848.64
2403606.59
5911675.77 12290131
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing br no- 241/1 Ch- 240272
Item No. Particulars/Descrption of items 2 Foundation
Providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. Well. (A) 'Assuming depth of water 1.0 m and height of Each island to be 1.25m. (c)'Providing and constructing one span service road to reach island location from one pier location metre to another pier location 2/12.10 Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation Tonne complete as per drawing and technical specification. 3/12.11 Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. (A) 'Well curb 1/12.9
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
9.00 162.00
57977.00 2472.00
521,793.00 400,464.00
85.54
101302.00
8,664,968.00
10003.00
14,260,277.00
9169.00 171,103,263.00
8924.00
22,894,790.00
8133.00
1,349,103.00
9030.00
17,268,972.00
Item No.
Particulars/Descrption of items 2
Unit 3
cum
5/12.21 Sand filling in wells complete as per drawing and technical specifications 6/12.40 Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant reinforcement bar of Fe-500 N/mm2 Steel (CRS)
tonne
1285.93
73279.00
94,232,008.00
Subsructure
7/13.5 Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999 (H) 'RCC Grade M35 Case-II : 'With Batching Plant, Transit Mixer and Concrete Pump Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
Cum
681.89
9169.00
6,252,210.00
8/13.6
(i) TMT Corrosion Resistant Steel (CRS) Tonne 169.63 reinforcement bar of Fe-500 N/mm2 9/13.12 Supplying, fitting and fixing in position true to line and level forged steel roller bearing conforming to tonne IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH 5400.00 capacity specifications complete including all accessories as per drawing and Technical Specifications. 10/13.11 Supplying, fitting and fixing in position true to line and level cast steel rocker bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH tonne 5400.00 specifications complete including all accessories as capacity per drawing and Technical Specifications.
73343.00
12,441,082.00
1191.00
6,431,400.00
953.00
5,146,200.00
Superstructure
11/14.1 Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. (E) 'PSC Grade M-40 Case II : 'Using Batching Plant, Transit Mixer and Concrete Pump (ii) 'For T-beam & slab (a) Height upto 5m
Cum
3320.00
10920.00
36,254,400.00
Item No.
12/14.2
Particulars/Descrption of items 2
Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in superstructure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
Unit 3
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
(i) TMT Corrosion Resistant Steel (CRS) Tonne reinforcement bar of Fe-500 N/mm2 13/14.3 High tensile steel wires/strands including all accessories for stressing, stressing operations and Tonne grouting complete as per drawing and Technical Specifications 14/14.5 Mastic Asphalt (A) Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal sqm size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515. 15/14.7 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space metre between vertical posts for expansion, complete as per approved drawings and technical specifications. 16/14.22 Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their metre authorised representative ensuring compliance to the manufacturer's instruction for installation). 17/8.4 Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand) (v) 80cmm x 45 cm rectangular
419.00
77554.00
32,495,126.00
126.00
167708.00
21,131,208.00
2875.04
329.00
945,889.00
338.24
2044.00
691,363.00
132.00
11804.00
1,558,128.00
Sqm
8.64
5200.00
44,928.00
Item No.
Particulars/Descrption of items
Unit
Total Quantity 4
Rate in Rs. 5
Amount (Rs.) 6
2 3 Cement Concrete Crash Barrier(Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia,450mm long at expension joints filled with free moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circuler No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified. B. M 40 grade concrete metre 19/Analy HAND RAIL sis Rate Providing and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The metre thickness of plates to be as shown in the drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only. (Rate from Annexure-I)
18/8.22 Reinforced 20/13.9 Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification (A) 'Granular material 21/13.8 Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification. 22/14.9 Drainage Spouts complete as per drawing and Technical specification 23/14.10 leveling course below approach slab complete as per drawing and Technical specification' (PCC M15 Grade) 24/14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification (A) With TATA make TMT CRS (Fe-500) grade 25/14.16 rebar Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. )
676.48
4170.00
2,820,922.00
676.48
1475.00
997,808.00
Cum
837.28
1524.00
1,276,020.00
Each
40.00
204.00
8,160.00
Each Cum
40.00 28.80
10197.00 5498.00
407,880.00 158,343.00
Cum
28.80
12025.00
346,320.00
Item No.
Particulars/Descrption of items 2
Unit 3 RM
(B) For RCC Railing 26/8.47 Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).
a) Bi-directional Studb) Uni-directional Stud27/8.51 Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&Hs fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Each Each
4.00
3500.00 3400.00
13,600.00
Each
100.00
298.00
29,800.00
28
Protection work Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications. Cum Providing and laying pitching on slop laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specification . Cum a) Stone/Boulder Providing nad laying boulder apron on river bed for protection against scour with stone/boulders weighing not les than 40 kg each complete as per drawing technical Cum specifications. 888.990 1862.00 1655300.00
29
2666.980
1463.00
3901792.00
30
513,720,807.00
12883592.00
Unit
Qty for 2Lane 9.00 162.00 85536.00 85.54 1425.60 18661.06 2565.53
11
1 9 60.00
9 Nos. 3 18 m 129.60 kg T m
3
11 129.60
11
233.23
m3 3 m
4 Sinking of well 0 to 3 m 11 3 to 10 m 11 10 to 20 m 11 20 to 30 m 11 5 Sand fill 11 x /4 x 8 x 26.4 6 Reinforcement in foundation (HYSD bars): Well Curb mm dia 11 8.5 188 12 mm dia 12 11 1.8 188 mm dia 20 11 28.5 16 Steining 20 20 20 20 12 12 Abutment well cap 28 28 20 20 Pier 32 28 mm dia mm dia 9 9 120 96 8 8 mm dia mm dia mm dia mm dia mm dia mm dia 2 2 9 9 11 11 200 180 200 180 135 135 32.5 32.5 32.5 32.5 38.5 2.5
3 7 10 10
Kg Kg Kg
2 180
Kg Kg Kg Kg Kg Kg
2 2 2 2
Kg Kg Kg Kg
2 2
Kg Kg Kg Tonne
Sl. No. 7
Dirt wall Abutment Cap Return wall Abutment Pier Cap Pier 8 Reinforcement in substructureDirt wall Return wall Abutment Cap Abutment32 mm dia 32 mm dia 32 mm dia 12 mm dia 12 mm dia Pier Cap Pier 32 12 mm dia mm dia 2 9 9 26.8 78 16 5.94 6.32 0.89 TotalTotal2 2 4 2 9 9 0.3 0.23 0.6 1+1.5 2 27 2.36 3.36 1 3.27 3.13 12 12 4 12
Unit
0.3
m 3 m 3 m m3
1.20
12
m3 m3 Total- m3 kg kg kg
2 4 2 2 2 2 2 2 9
2007 620 600 5.96 8.95 5.96 27 97 9100 97 49 61 21 21 6.32 6.32 6.32 0.89 0.89
1.5
kg kg kg kg kg kg
52715.520 3430.400 169628.754 169.629 5400.00 5400.00 3320.00 419.00 419.00 0 126.00 2875.04 338.24 132.00 676.48 837.28 28.80 40.00 40.00 28.80 1014.72 4.00 100.00 8.64 676.48
9 10 11 12
Roller bearing10 Rocker Bearing10 Super struture (RCC M-40) Reinforcement bar in super structure (TMT CRS) -
4 4 10
41.9 T T 10 12.6 Sqm Rm m 6.709 m3 28.8 m3 Nos. Sqm 12 m3 Sqm 4 Nos. Nos. Sqm m
13 HTS Stand 14 Wearing coat(Mastic Asphtl)15 16 17 18 19 20 21 22 23 24 25 26 27 1 8.5 338 RCC Railing1 Strip seal Expansion Joint11 Crash barrier 2 Back fill behind abutment 2 5.20 Leveling course (M-15) (Below approach slab)Weep holes 2 Drainage spout 10 Apprpoach slab (M25) 2 4 Painting 3 Soler stud RPM 1 Sign board 2 Hand rail for crash Barrier : 2 338.24 12 338.24 12
20 4
Sl. No.
Unit
Name of Work: 4 Lane Connectivity from Nagaon to Itanagar in Arunachal Pradesh under SARDP NE Work (Phase A). 4 Laning of NH 52 from the end of Biswanath Chariali by-pass (Km 208.00) to Gohpur (km 265.5) (Total Length = 57.50 km) in Sonitpur district in the state of Assam Ref : Based on SOR 2013-2014 for Roads and Bridge Works,PWD,Assam. Esstt of existing br no- 209/1 Ch- 208415 m
Rate in Total Rs. Quantity 4 5
Item No. 1
Particulars/Descrption of items 2
Part-A. : BRIDGE PROPER
Unit 3
Amount (Rs.) 6
Foundation
1 /12.9 Providing and constructing temporary island 20m diameter for construction of well foundation for 12m dia. Well complete as per Drawing and MoSRT&H's Technical Specification Nos. 1200 . A) Assuming depth of water 1.0 m and height of island to be 1.25m. B) Assuming depth of water 4.0m and height of island 4.5m. C) Providing and constructing one span service road to reach island location from one pier location to another pier location. Well Foundation Providing and Laying Cutting Edge of Mild Steel weighing 40 kg per metre for Well Foundation complete as per Drawing and MoSRT&H's Technical Specification Nos. 1200 & 1900. Plain/Reinforced Cement Concrete, in Well Foundation complete as per Drawing and MoSRT&H's Technical Specificationcl Nos. 1200,1500 & 1700 A. Well Curb IV) RCC M - 35 grade Case - I : Using concrete mixer. B. Well steining VIII) RCC M- 35 grade Case I : Using concrete mixer. C. Bottom Plug IV) PCC grade M-35 Case - I : Using concrete mixer. D. Intermediate plug lII) PCC grade M - 30 Case - I : Using concrete mixer. F. Well Cap IV) RCC M - 35 grade Case - I : using concrete mixer. Sinking of 12m external diameter well (other than pneumatic method of sinking ) through all types of soil strata namely sandy soil,clayey soil and rock complete as per Drawing as per MORTH Section No. 1200 . A. Sandy soil I) Depth below Bed level up to 3.0m II) Beyond 3.0 m upto 10.0 m III) Additional depth beyond 10m up to 20m IV)Additional depth beyond 20m up to 30m. With Kentledge.
(a) For sinking
2 /12.10
MT
19.45
101302.00
1970324.00
3 /12.11
Cum
389.04
8319.00
3236424.00
Cum
4146.92
7626.00
31624412.00
Cum
699.690
7356.00
5146920.00
Cum
45.240
6888.00
311614.00
Cum
605.680
7140.00
4324556.00
4/12.18
15.00
128301.00
1924515.00
5 /12.21
Sand Filling in Wells complete as per drawing and as per Technical Specification as per MORTH Cum Section No. 1207 .
3242.130
1798.00
5829350.00
Item No.
Particulars/Descrption of items
Unit 3 MT
Amount (Rs.) 6
fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2
338.40
73279.00
24797614.00
Substructure
7 / 13.5 (B) Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications cl. no. 1500,1700 & 2200 including providing plasticiser ( Masterplast PL-1 SPL-2 OR equivalennt)air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS: 1903-1999 and steel shuttering formwork H) RCC Grade M 35 Cum b)Height 5.0m to 10.0m Case-I : Using Concrete Mixer
Reinforcement in Foundation: Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel (i) TMT Corrosion Resistant Steel (CRS) reinforcement bar of Fe-500 N/mm2
220.35
8801.00
1939292.00
8 / 13.6
MT
32.30
73343.00
2368979.00
9 / 13.11 Supplying, fitting and fixing in position true to line and level cast steel rocker bearing conforming to IRC: 83(Pt.-I) section IX and clause 2003 of tonne MoRTH specifications complete including all accessories as per drawing and Technical Specifications. Supplying, fitting and fixing in position true to line and level forged steel rocker bearing conforming to IRC: 83(Pt.-I) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical 10/13.12 Specifications. tonne
1550.00
953.00
1477150.00
1550
1191.00
1846050.00
Superstructure
11/ 14.1 Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification including providing plasticiser ( Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS: 1903-1999 and steel shuttering formwork as per specification and direction of Engineer in charge. D. RCC/PSC grade M - 35 Case I : Using concrete mixer (ii)For T beam and slab, b) Height 5.0m to 10.0 m Cum
and placing TMT bar reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) From Primary Sources: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel
1016.00
8889.00
9031224.00
Item No. 1
Particulars/Descrption of items 2
Unit 3
(i) TMT Corrosion Resistant Steel (CRS) reinforcement Tonne bar of Fe-500 N/mm2
High tensile steel wires/strands including all accessories for stressing,stressing operations and grouting complete as per drawing and Technical specifications. 14/14.4 Providing and laying cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical specification of section 1800 of MORTH Specification of Roads and Bridge Work . 15 / 14.22 Providing Strip Seal Expansion (Providing and laying strip seal expansion joint catering to maximum horizontal movement upto 70mm complete as per drawing and clause no 2607 of MORTH Specification of Roads and Bridge Works for superstructure works to be installed by the manufacturer / supplier or their authorise representative ensuring compliance to the manufacturer's instruction for installation. 16 /8.22 RCC Crash Barrier (provosion of an RCC crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with concrete with HYSD/ TMT reinforcement conforming to IRC:21 and dowel bar 25mm dia, 450mm long at expansion joints filled with pre moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circular No. RW/ NH 33022/ 1/ 94-DO III dated June 1994 as per B. M 40 grade concrete 17 / 14.9 Providing Drainage Spouts complete as per approved drawing and technical specifications clause 2705 of MORTH Specification of Roads and Bridge Works for superstructure works Miscellaneous Works 18 / 13.9 Back filling behind abutment, wing wall and return wall complete as per drawing and clause no 710.1.4 of IRC:78 & 2200 MORTH Specification. (A) Granular material 13/14.3
Tonne
48.4
167708.00
8117068.00
Cum
1086.960
12993.00
14122872.00
Metre
44.40
11804.00
524098.00
Metre
4170.00 10197.00
863357.00 101970.00
Cum
778.98
1524.00
1187166.00
19 /14.10 PCC M15 Grade levelling course below approach slab complete as per approved drawing and Cum technical specifications clause 2700 of MORTH Specification. 20 / 14.11 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Cum
Technical specification (A) With TATA make TMT CRS (Fe-500) grade rebar
34.08
5498.00
187372.00
34.08
12025.00
409812.00
21 /13.8
Providing weep holes in brick masonry ,plain/Reinforcement concrete abutment,wing wall/return wall with 100mm dia AC pipe,extending through the full width of the structure with slope of each 1V:20H towards drrawing force complete as per approved drawing and technical specifications.
40.00
204.00
8160.00
Item No.
Particulars/Descrption of items
Unit 3
Amount (Rs.) 6
1 2 22 /14.16 Painting on concrete surface (providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust,oil,grease,efflorescence and applying paint @ of 1 litre for 2 Sqm.) complete as per drawing and technical specifications clause 800 of MORTH Specification of Roads and Bridge Works for superstructure works
(B) For RCC Railing
23/8.47 Providing
Rm Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per Each minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).
207.04
160.00
33127.00
b) Uni-directional Stud-
4.00
3400.00
13600.00
Direction and place identification sign more than 0.9sqm size board. Providing and erecting direction and place identification retro-Reflectrorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3 fixed over aluminium sheeting, 2mm thick with area exceeding 0.9sqm fixed on an sqm angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm, 2 nos. firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. . ( All the Steel work 25/8.51 Providing reflective pavement marker with a provision of spike at the bottom with Micro Prismatic lens in both direction having thermoplastic body adhering to the specification Each and guidelines of MORT&H's fixed to the road surface using the adhesive and the procedures recomment warranty and free maintenance. Providing 26/Analysis rate HAND RAIL : and fixing hand rail over the crash barrier consisting of MS base plate, embedded fastener and nuts, MS vertical plates and pipe etc. as shown in the drawing and as per specifications, All the railing components as mentioned above to be hot dip gal vanished with a zinc coating of at least 175gm/sqm. The thickness of plates to be as shown in the meter drawings and pipe to be 65NB heavy class with a weight not less than 7.92 kg/m and conforming to IS: 1161-1979. Item to include all incidental works required to complete the work as directed by the Engineer- in-charge. Management shall be made for the length of the pipe only
24/8.6
8.64
11000.00
95040.00
100.00
298.00
29800.00
207.74
1475.00
306417.00
Particulars/Descrption of items
Unit
Amount (Rs.) 6
2 3 Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between meter vertical post not to exceed 2000mm,leaving adequate space between vertical posts for expansion,complete as per approved drawings and technical specification.
207.74
2100.00
436254.00
Protection Work 1 Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications . 0.3*9.32*[26.2+[4*40]+[2*14.8]]=603.38 Cum 2 Providing and laying pitching on slope laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and drawing technical specifications . a ) Stone / Boulder 0.5*9.32*[26.2+[4*40]+[2*14.8]]=1005.63 Cum 3 Providing and laying boulder apron on river bed for protection against scour with stone/ boulders weighing not less than 40 kg each complete as per drawing and drawing technical specifications . 5.0*[1.2+0.8]/2*[[68.09+[4*40]+[2*14.8]]=1288.45 Cum 1288.45 1463.00 1885002.35 142,509,647.60 1005.630 1463.00 1471236.69 603.380 1862.00 1123493.56
142,509,647.60
2 3 4
m m3 m3 m3 Nos. m 3 50 129.68 T
PCC/RCC work in well foundation: a) Well curb (RCC M-35) 3 b)Well Steining (RCC M-35) 3 /4(122-82) c) Bottom Plug (PCC M-30) 3 d) Intermediate Plug (PCC M-30) 3 e) Well Cap (RCC M-35) 2 1 Sinking of well 0 to 3 m 3 to 10 m 10 to 20m 20 to 25 m Sand fill =
m3 m3 m3 m3 m3 m3 m3 m m m m m3
3 3 3 3
3 7 10 5
6 7
3 x /4 x 82 x 21.5 Reinforcement in foundation (HYSD bars): Well Curb 12 3 140 8.4 12 3 140 1.2 6 20 3 16 32.5
0.89 Kg 0.89 Kg 2.47 Kg Kg Kg Kg Kg 4.84 4.84 0.89 0.89 6.32 6.32 2.47 2.47 Kg Kg Kg Kg Kg Kg Kg Kg
3139.920 2691.360 3853.200 0.000 0.000 0.000 0.000 67881.000 63888.000 26726.700 131577.600 10636.560 11387.376 5394.480 5394.480 8089.600 4646.400 345306.68 690613.352 345.307 690.613
Steining 28 28 12 12 Abutment well cap 32 32 20 20 Pier well cap 32 28 1 1 160 120 8 8 6.32 Kg 4.84 Kg Kg T 2 2 2 2 99 99 120 120 8.5 9.1 9.1 9.1 3 3 3 3 170 160 154 154 27.5 27.5 32.5 160
2 2
Sub structure (RCC M-35) Dirt wall = 2 0.3 14.8 3.86 Abutment cap = 2 14.82 Return wall = 2 x 2((0.60 x 4) + (2.67 x 4)/2) x 0.30 Abutment = 2 1.2 2 14.8 Pier Cap = 1 32.904 Pier = 2 1.5 1.2 12 Reinforcement in substuctureDirt wall = Return wall Abutment Cap Abutment Pier 2x 2x 2.1= 2=
m3 m3 3 m m3 3 m 3 m 3 m
34.277 29.640 9.29 71.04 32.904 43.200 220.349 4100.000 4200.000 4000 12000.000 8000.000 32300.000 32.300 1550 1550 1016 1016.00 144.62 144.62 48.4 1086.96 207.04 44.40 207.04 778.99 34.08 40 10 34.08 207.04 4 100 8.64 207.04
440.6976
4.1 T 4.2 T 4T 12 T 8T
2 2
5 5 2
13 Reinforcement bar in super structure (TMT CRS): = 2 72.31 14 Reinforcement bar in super structure (High tensile steel): = 2 24.2 15 Wearing coat (Mastic Asphalt): = 1 10.5 103.5 16 17 17 18 19 20 21 22 23 24 25 26 27 RCC Railing: = 2 103.52 Strip seal Expansion Joint: = 3 14.8 Crash Barrier 2 104 Back fill behind Abutment:= 2 5.20 14.8 Leveling course: (M-15) (Below approach slab):= Weep holes = Drainage spout = Approach slab (M-25): Painting Solar stud: RPM Sign Board Hand rail 2 2 2 20 5 103.5 1 2 2 100 4.32 103.52