Sie sind auf Seite 1von 3

actoolsupply.

com

Meeting & Exceeding Customers Value Propositions


Applications
Attics Dense Pack & Wall Spray
Driving Factor

Savings in Transportation Time and Fuel Costs offsets Larger systems' increased production rate Precision with Pressure / Product Flow

System Comparisons
Cost of Ownership Portability & Transport Energy Consumption Maintenance

Driving Factor 5 year cost ~ 1/5 to 2/3 that of competitive systems Portable -- No Specialized Equipment (i.e. dedicated truck) Requirements Powered by clean, quiet electric motors v. gas or diesel with associated pollution Minimal. Direct Drive System gear lubrication changed once/year; Seals changed only after 300 hours

actoolsupply.com

actoolsupply.com

Intec Turbo Force Hp3 40009 00 Insulation Blowing Machine Intec Turbo Force Hp3 40008 00 Insulation Blowing Machine Intec Turbo Force Hp3 40010 00 Insulation Machine Canada Intec Turbo Force Hp3 40011 00 Insulation Machine Canada Intec Turbo Force Hp3 40012 00 Insulation Machine Canada Intec Turbo Force Hp3 40005 00 Insulation Machine Canada Intec Turbo Force Hp3 40006 00 Insulation Machine Canada Intec Turbo Force Hp3 40007 00 Insulation Machine Canada

actoolsupply.com

actoolsupply.com

System Comparisons
u R1 ll T ft) 9 im in e 1 0 (m 00 in sq u Pr ft tes od at ) uc t ic t ap R a e op ble tro 1, f it pe 2 rC (# ap In ba a st gs cit al ) y R1 l T 9 im in e 1 0 (m 00 in sq u Pr ft tes od at ) uc t ic tio n (lb s/ P (b hr r ag o ) s / du ho c D t u i r o en se @ 3 n Pa 0lb/ b C ck R ag ) ap e H op able trof 2 it pe rC (# ap ba a gs cit ) y H

Customers value
s) ilit y (lb rta b gh t W ei Po er

cellulose
s/ (b Pr hr ag o ) s / du ho c t D en ur @ ion se 2 Pa 5lb/b ag C ck ) (c siz e n (lb

fiberglass

op p

System

Cyclone A FORCE/1 A FiberForce A,B

excellent

142 177 150 280 283 350 380

5.3 4.5 9 10 9 11.5 17

51 76 39 23 18 16 18

In st a

800 540 1050 1750 2280 2520 2475

32 22 42 70 91 101 99

io

no

1/2

74

204 187 400 475 615 1350 900

7 6 13 16 21 45 30

yes

1/3

above avg

no

1/2 - 1

81

yes

1/3

tall hopper avail

excellent

no

1-2 1+ 1-2

38

yes

1/2

WASP C FORCE/2 C FORCE/3 C

above avg

yes

30

yes

1/2

average

yes

27

yes

1/2

above avg

yes

15

yes

1/2 - 3/4

average

yes

2-3

19

yes

1/2 - 1

Notes: 1 Department Of Energy requires outlet pressure >=2.9psi (80" of water) for cellulose Dense Pack to achieve 3.5lbs/cu-ft density. 2 Dense Pack capability provides installers with additional market opportunities & resulting profit.

A Systems come standard with 100' 2-1/2" hose, connectors & clamps, & LED power cords. B All-fiber configuration with slide gate & tall hopper. C Systems come standard with LED power cords.

actoolsupply.com Versatile & Reliable Operation with Industry Leading Return on Investment

Das könnte Ihnen auch gefallen