Sie sind auf Seite 1von 3

MP 100 AIR FLOW BENCH

GENERAL DESCRIPTION This is a bench top unit for studying the air flow measurement and air flow characterisfies in optional apparatus. The set uses an industrial type centrifugal blower with inlet and outlet ducts, flow straighteners, a damper, various flow measuring devices using manometers for the study of air flow measurement according to BS 848 and 1042, ISO 5167. Various measuring devices for the study of air flow are provided as an option.

Photograph includes optional equipment

TYPICAL TESTS (Including optional accessories)

. Air flow measurement. . . Flow around a bend. . Air flow in pipes. . Free jet study. . Air flow drag. . layer. . Boundary Flow Visualization . . . .

TECHNICAL DATA Blower : - Type - Motor - Maximum flow rate (unchoked) - Maximum head ( fully choked) Inlet duct Outlet duct Measuring instruments: - Air flow rate - Differential pressures

: : : : : :

Industrial, centrifugal. 0.75 kW, 2900 rpm. Over 12 m3/min. Over 80 mm. water. 5 in or approximate equal with flow straightener. 4 in or approximate equal with flow straightener and damper.

. .Accessories Power supply . .

: Venturi nozzle, orifice plate, inlet cone, and traveling pitot using inclined water manometer. : Two inclined water manometers., 0-450 mm x 1 mm graduation, multiple slope 1:10, 1:5, 1:2 and 1:1. : Aneroid barometer and thermometer. : 220 V, 1 Ph, 50 Hz. : 75 x 245 x 130 cm (fully installed 75x275x200 cm) : Approx. 200 kg

Net shipping dimensions WxLxH Net weight

OPTIONAL EQUIPMENT MP 100-010 Anemometer, 0-20 m/s MP 100-011M Multiport differential pressure sensor and indicator, 0-250 mm water instead of inclined water manometers

MP 100-021 14 Tube Water Manometer The manometer is 450 mm high x 1 mm graduation with an adjustable height water reservoir. Manometer tube are clear acrylic. Pressure ports are at the top. It is to be used with MP 100-022 MP 100-023 Flow Around a Bend. Apparatus or MP 100024 Air Flow in Pipes Apparatus Net shipping dimensions WxLxH Net weight : 30 x 35 x 65 cm : Approx. 7 kg

.MP 330-114D

16 point differential pressure sensor with sequential readings instead of MP 100-021 14 Tube Water Manometer.

ESSOM CO., LTD. 508 Soi Taksin 22/1 Taksin Rd. Bukkalo Thonburi Bangkok 10600 Thailand Tel. +66 2476 0034 Fax. +66 2476 1500 E-mail : essom@essom.com,http://www.essom.com We reserve the right to change specifications without notice

EC 170812

. MP 100-

flow using air from MP100 Air Flow Bench and MP100-021 14 Tube Water Manometer (both are separately supplied). The apparatus is a rectangular Venturi duct 60x50 mm converging to 20x50 mm throat. The front and rear walls are transparent with scales. Pressure taps are fitted along the upper wall with a total head probe along the axis of the duct. The pressure taps are connected to the 14 tube manometer (optional item) The duct is connected to the blower outlet by a hose. Net shipping dimensions WxLxH Net weight : 31 x 65 x 60 cm : Approx. 9 kg

. MP 100-023 Flow Around a Bend Apparatus.


This apparatus demonstrates pressure distribution along a pipe bend using air from MP100 Air Flow Bench and MP100-021 14 Tube Water Manometer (both are separately supplied). A straight duct is connected to a 90 bend. Duct section is 60x50 mm with a transparent front and rear walls. Pressure taps are fitted along both upper and lower walls of the bend and are connected to the 14 tube manometer (optional item) for a study of pressure distribution along the upper and lower walls. The duct is connected to the blower outlet by a hose. Net shipping dimensions WxLxH Net weight : 25 x 75 x 45 cm : Approx. 8 kg

. MP 100-024 Air Flow in Pipe Apparatus


This apparatus measures pressure profile along inlet duct length, duct enlargement, and duct with different inlet devices as well as velocity profile across the duct. It is to be used with MP100 Air Flow Bench and MP100-021 14 Tube Water Manometer (both are separately supplied). The apparatus consists of two long sections of duct with different diameters connected to the blower inlet duct. Pressure taps are provided along the duct length. Provision is also made for insertion of a pitot tube near the front and rear ends of the duct. Three different inlet devices are provided i.e. sharp, bellmouth and bluff. The pitot tube and the inclined monometer provided in the main equipment measure the air velocity while the 14 tube monometer (optional item) measures the pressure profile. Net shipping dimensions WxLxH : 30 x 153 x 23 cm

. MP 100-025 Dispersion of Jet Apparatus.


This apparatus measures velocity profile of an air steam leaving a tube into free surrounding using air from MP100 Air Flow Bench (separately supplied). The apparatus consist of a 6 inch diameter plenum chamber with 2 inch diameter outlet tube. The chamber is connected to the blower outlet duct by a hose. A pitot tube and an inclined manometer provided in the main equipment measure the air velocity. This pitot tube is fitted above the plenum such that it can be moved across plenum or up and down. Scales are provided to measure the position of the pitot tube. Net shipping dimensions WxLxH Net weight : 30 x 30 x 80 cm : Approx. 8 kg

ESSOM CO., LTD. 508 Soi Taksin 22/1 Taksin Rd. Bukkalo Thonburi Bangkok 10600 Thailand Tel. +66 2476 0034 Fax. +66 2476 1500 E-mail : essom@essom.com,http://www.essom.com We reserve the right to change specifications without notice

EC 170812

MP 100-028 Drag Apparatus. This apparatus measures drage force vs angle of attack on a model in a duct using air from MP100 Air Flow Bench (separately supplied). The apparatus consists of a rectangular duct 100x50 mm with a beam balance mechanism on the outlet end. The duct is connected to the blower outlet by a hose. Three models : MP 100028A Flat Plate, MP 100-028B Cylinder, and MP 100-028C Aerofoil NACA 0015 are supplied for attachment to the beam balance. A pitot tube and an inclined manometer provided in the main equipment measure the air velocity. Net shipping dimensions WxLxH Net weight : 49x 30 x 100 cm : Approx. 6 kg

EC 200511

. MP 100-029 Boundary Layer Apparatus.

The apparatus provides a means of measuring air velocity near a flat plate in a duct using air from MP100 Air Flow Bench (separately supplied). The duct section is 60x50 mm with a transparent cover. The duct is connected to the blower outlet by a hose. A flat plate is installed along the center line of the duct. A small pitot tube and an inclined manometer provided in the main equipment measures the air velocity near the plate. A micrometer measures the distance of the pitot tube from the flat plate. Net shipping dimensions WxLxH Net weight : 22 x 80 x 22 cm : Approx. 6 kg

ESSOM CO., LTD. 508 Soi Taksin 22/1 Taksin Rd. Bukkalo Thonburi Bangkok 10600 Thailand Tel. +66 2476 0034 Fax. +66 2476 1500 E-mail : essom@essom.com,http://www.essom.com We reserve the right to change specifications without notice

EC 170812 EC 200511