This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed.
DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Hvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com Form No.: 20.100a Issue: October 2009 Page 1 of 3
Product description
ASEplas 2010SWA, 2010SWB, 2010SWC, 2010SWC1 and 2010SWD; Organic glass-reinforced polyester composites for use as Thermal Isolator Blocks for Petrochemical and LNG Tanker applications.
The following properties have been verified by Type Testing: ASEplas 2010 SWC 1,22 21 64 111 25 86
Properties Density [g/cm3] Compressive strength, +150C [MPa] Compressive strength, 20 C [MPa] Compressive strength, -196 C [MPa] Shear strength, 20 C [MPa] Water resistance (Compressive strength, 20C) [% of original strength] Service temperature [ C] Thermal conductivity, 20C [W/mK]
Remark; Note that retention of compressive strength is less than the minimum 98% given by the Type Approval Programme No. 1-503.2, but the samples are tested without sealing of the cut edges. Other properties may be requested from the Holder of Certificate.
Manufactured by
Torgy Atlantic Ltd., Llandough Industrial Estate Penarth Road, CF11 8RR Cardiff, United Kingdom DNV local office: Bristol
Responsibility
The Holder of Certificate takes the responsibility that both design and production are in compliance with Rules, Standards and/or Regulations listed on page 1 of this certificate.
Application/Limitation
Area of application will be evaluated during approval of classified objects. Additional properties may be requested.
UL-94, Vertical Burning Test for Classifying Materials V-0, V-1 or V-2, Exova Report 198031 of UL-94, Vertical Burning Test for Classifying Materials V-0, V-1 or V-2, Exova Report 198032 of UL-94, Vertical Burning Test for Classifying Materials V-0, V-1 or V-2, Exova Report 198033 of UL-94, Vertical Burning Test for Classifying Materials V-0, V-1 or V-2, Exova Report 198034 of UL-94, Vertical Burning Test for Classifying Materials V-0, V-1 or V-2, Exova Report 198035 of
Marking of product
Product shall be marked with manufacturer's name; Torgy Atlantic Ltd., Cardiff, UK and type designation.