Copper and copper alloys - seamless, round copper tubes for water and gas in sanitary and heating applications
EN 1057 - TYPE Y
Size mm 6 8 10 12 15 18 22 28 35 42 54 66.7 76.1 108 Nom. Dia. (Outside) mm 6 8 10 12 15 18 22 28 35 42 54 66.7 76.1 108 Nom. Wall Thickness mm 0.8 0.8 0.8 0.8 1.0 1.0 1.2 1.2 1.5 1.5 2.0 2.0 2.0 2.5
+1
(PREVIOUSLY BS 2871 TABLE Y) Max. Working Pressures* Half Hard bar+ 188 136 106 87 87 72 69 55 54 45 47 37 33 29 bar = 0.1N/mm = 10 5 N/m Hard bar+ 223 161 126 104 104 85 84 65 65 54 56 45 39 34 Annealed bar+ 144 105 82 67 67 55 53 42 41 34 36 28 25 22
Usage: Underground w orks and heav y duty requirements including hot and cold w ater supply, gas reticulation, sanitary plumbing, heating and general engineering.
EN 1057 - TYPE X
Size mm 6 8 10 12 15 18 22 28 35 42 54 66.7 76.1 108 133 159 Nom. Dia. (Outside) mm 6 8 10 12 15 18 22 28 35 42 54 66.7 76.1 108 133 159 Nom. Wall Thickness mm 0.6 0.6 0.6 0.6 0.7 0.8 0.9 0.9 1.2 1.2 1.2 1.2 1.5 1.5 1.5 2.0
+1
(PREVIOUSLY BS 2871 TABLE X) Max. Working Pressures* Half Hard bar+ 133 97 77 63 58 56 51 40 42 35 27 20 24 17 14 15 bar = 0.1N/mm = 10 5 N/m Hard bar+ 161 118 93 76 71 67 62 48 51 43 33 27 29 20 17 18 Annealed bar+ 102 75 59 48 45 43 39 31 33 27 21 17 18 13 10 12
Usage: Abov e groundserv ices including drinking w ater supply, hot and cold w ater systems, sanitation, central heating and other general purpose applications.
EN 1057 - TYPE Z
Size mm 6 8 10 12 15 Nom. Dia. (Outside) mm 6 8 10 12 15 Nom. Wall Thickness mm 0.5 0.5 0.5 0.5 0.5
0.5 0.6 0.6 0.6 0.7 0.8 0.9 1.0 1.2 1.2 1.5 1.5
+
Usage: Abov e groundserv ices including drinking w ater supply, hot and cold w ater systems, sanitation, central heating and other general purpose applications.
# Note: Elongations for half hard tubes depend on the ratio of outside diameter to wall thickness. * MPa: Minimum tensile strength ** Hardness HV/5 indicative
2014, Crane Enfield Metals Pty Ltd. A ll Rights Reserv ed. Priv acy Policy | Disclaimer