Beruflich Dokumente
Kultur Dokumente
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com RC. 413243
Limited
Date 07/12/2013
Date of Manufacture
05/06/1997 (a) Maker Serial number 010384 Date of last previous test of Crane 09/05/2012 Location:
FABRICATION EAST
(b) Owners distinguishing mark or number (if any) OH-12 Date of last thorough examination of the Crane Not seen Proof Load 6.25T
Rated Load
5.12T
S.W.L 5T
10mm of wire rope @ 4falls 136.07mtrs Comment noted and alterations or repairs required before Crane is put into service (if none enter NONE)
Maintenance should be properly done Bell alarm should be fixed before use
JC International Ltd.
Page 1 of 3
CONDITION OR INSPT REQUIREMENT Structural Frame/Beams Access Walkways Railways/Rollers Anchoring/End Stops Use Visibility Brake Systems Parking Counterweights Wind Anchoring Motor Train/Controls Electric Power Supply Operational Protections Warning Devices Hydraulic lines/ Air Lines Hooks/Tackles Chain Pulleys & Drum Speed Limit Switches Transverse Limit Switches Longitudinal Limit Switches High & Low Lift Switch Limit Load Devices Fire Extinguisher(s) Safety Markings Maintenance Cleanliness/Up-Keep
NEEDED CORRECTIONS(IF ANY) OR DEFECTS NOTED Ok Ok Ok Ok Ok OK N/A Ok 415V,good N/A Ok Ok Ok Ok Ok Ok OK Ok Ok Ok Ok Ok OK Needs maintenance poor
Inspector Signature:.
KELECHI EMERIBE
Inspectors Name:
LEEA Qualified Lifting Equipment Tester and Inspectors Qualification: SNT LEVEL 11 MT, PT & UT IN COMPLIANCE WITH SNT-TC-1A
07/12/2013 Date:.
Page 2 of 3
JC International Ltd.
6513 07/12/2013
Inspector:
D
D/R R
Deficiency
ITEM#
R=
Recommendation
EXPLANATION/RECOMMENDATION the bell alarm should be fixed before use Proper maintenance should be done on the crane
JC International Ltd.
Page 3 of 3
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Equipment Description: Client: Inspection Location: Crane Manufacture: Date of Manufacture: Owner Mark Number: Serial Number: SWL: Proof Load Applied: Certificate Number: Inspection Date: Next Date of Examination:
This is to certify that I did, Test / Examination on the Overhead Crane in accordance with BS 7121-2 and all Statutory requirement as above. The records of examination are true without prejudice for the purpose it was designed for. Fit for use
Inspectors Name/Qualification KELECHI EMERIBE LEEA Qualified Lifting Equipment Tester and SNT LEVEL 11 MT, PT & UT IN COMPLIANCE WITH SNT-TC-1A 07/12/2013 Signature/Date
Cert No.227173