Sie sind auf Seite 1von 2

ChloRid

TM
SERIES
Aquafine ChloRid
TM
systems for chlorine and chloramines destruction
utilize medium-pressure (MP) lamp technology and are well suited for
flow rates greater than 25gpm given the efficiencies gained in meeting
dosage intensive applications while being economically competitive.
The ChloRid
TM
series consists of 316L stainless steel treatment chamber
and a NEMA 12 painted carbon steel control cabinet, featuring a
microprocessor-based controller. The incorporation of MP high
intensity ultraviolet (UV) lamps reduces the number of lamps by 90
percent, reducing footprint and downtime requirements and decreasing
installation and maintenance costs.
With a reduced footprint, higher flow rates and state-of-the-art MP
technology, Aquafines ChloRid
TM
systems are an innovative, reliable
and environmentally responsible alternative. ChloRid
TM
systems are CE
compliant. NSF & cULus pending.
I
N
D
U
S
T
R
I
E
S


|


R
e
c
r
e
a
t
i
o
n
a
l

W
a
t
e
r
,

F
o
o
d

&

B
e
v
e
r
a
g
e
,

L
i
f
e

S
c
i
e
n
c
e
s
F
L
O
W
R
A
T
E
S
:

1
4
-
5
0
G
P
M

@

9
0
%
U
V
T
,


7
8
6
-
2
8
9
5
G
P
M

@

9
5
%
U
V
T
,

3
0
-
1
1
2
G
P
M

@

9
8
%
U
V
T
Aquafine ChloRid
TM
series for
chlorine and chloramines
utilizing MP lamp technology
are the systems of choice
for meeting the rigid quality
standards of the Recreational
Waters, Life Sciences and Food &
Beverage markets.
UV TECHNOLOGY
Used effectively as a system for the
reduction of chlorine and chloramines, MP
lamp technology produces significantly higher
levels of UV energy than low-pressure (LP)
lamps, resulting in fewer lamps. MP lamps
are polychromatic and produce a broad
range of wavelengths, highly effective in
inactivating microorganisms and reducing
chemical compounds present in water.
SAFE & EFFECTIVE
UV does not add anything to the water
stream such as undesirable color, odor,
chemicals, taste or flavor, nor does it
generate harmful by-products. UV only
imparts energy to the water stream in
the form of ultraviolet light to reduce the
chlorine or chloramines present.
Utilizing medium-pressure lamp technology, Aquafines ChloRid
TM
series meets and
exceeds the diverse needs of market specific applications for the destruction
of chlorine and chloramines.
High Performance UV Systems
SHOWN
ChloRid
TM

4L
A
P
P
L
I
C
A
T
I
O
N
S


|


C
h
l
o
r
i
n
e
/
C
h
l
o
r
a
m
i
n
e
s

D
e
s
t
r
u
c
t
i
o
n
D
E
S
I
G
N

C
A
P
A
B
I
L
I
T
I
E
S


|


C
u
s
t
o
m

C
o
n
f
i
g
u
r
a
t
i
o
n
s
ChloRid
TM
Series
60 Years of Pure Quality
ISO
9001:2000
Certified C
e
lebrating 50 Years of Service

Model : Chl oRi d
TM
1L 2L 4L
MARKETS & MAXI MUM FLOW RATE
REC. WATERS @95% UVT GPM (M
3
/ HR)* 786 ( 178. 6) 1549 ( 352. 1) 2895 ( 658)
F & B, LI FE SCI ENCES @90% UVT GPM (M
3
/ HR)** 14 ( 3. 18) 27 ( 6. 14) 50 ( 11. 36)
F & B, LI FE SCI ENCES @98% UVT GPM (M
3
/ HR)** 30 ( 6. 8) 60 ( 13. 6 112 ( 25. 5)
NUMBER OF UV LAMPS (MP) 1 2 4
ELECTRI CAL REQUI REMENTS
ELECTRI CAL SUPPLY 240VAC/ 60Hz, SI NGLE PHASE, 2 W + GND 240VAC/ 60Hz, SI NGLE PHASE, 2 W + GND 480- 277VAC/ 60Hz, 3 PHASE, 4 W + GND
OPERATI NG POWER (NOMI NAL WATTS) 3250 6500 12480
BALLAST TYPE ELECTRONI C
CONTROLLER/ DETECTOR
UV VI SI ON 2000 UV G400 SERI ES
LAMP STATUS I NDI CATOR STANDARD
LAMP OUT ALERT STANDARD
RUNNI NG TI ME METER STANDARD
HAND OFF AUTO (HOA) 24VDC STANDARD
UV SENSOR STANDARD
CONTROL CABI NET
CONTROL CABI NET SYSTEM RATI NG NEMA 12
MATERI ALS OF CONSTRUCTI ON PAI NTED CARBON STEEL ( STAI NLESS STEEL OPTI ONAL)
ENCLOSURE HI GH TEMP WARNI NG STANDARD
CABI NET DI MENSI ONS - HXWXD I NCHES (MM) 48 X 36 X 18 ( 129. 2 X 914. 4 X 457. 2)
TREATMENT CHAMBER
MATERI ALS OF CONSTRUCTI ON 316L STAI NLESS STEEL
I NTERNAL SURFACE FI NI SH Ra 32 ( Ra 15 OPTI ONAL)
OPERATI NG TEMPERATURE F ( C) Wat er : 50 - 104 ( 10 - 40) Ambi ent Ai r : 35 - 100 ( 2 - 38)
MAX. OPERATI NG PRESSURE PSI (BAR) 150 ( 10)
I NLET/ OUTLET FLANGE SI ZE*** I NCHES (MM) 6 ( 152. 4) 8 ( 203. 2) 10 ( 254)
AUTOMATI C WI PER STANDARD
Specifications:
TSG 241A-09 Printed in USA. Aquafine Corporation 2009. All rights reserved. This document is not to be copied, electronically stored or reproduced without written permission from Aquafne Corporation.
North America & International Europe
29010 Ave Paine, Valencia, CA 91355 Ramskamp 77-85 D-25337 Elmshorn, Germany
p. 661-257-4770 f. 661-257-2489 p. +49 (4121) 57806-13 f. +49 (4121) 57806-30
tf. 800-423-3015 (within domestic U.S.A. and Canada)
A TROJAN TECHNOLOGIES COMPANY
www.aquafineuv.com sales@aquafineuv.com
ChloRid
TM
Series High Performance UV Water Treatment System
All specifications are subject to change without notice.
For additional requirements, please contact Aquafine Corporation.
* Dose Level: >60 mJ/cm
2
after 5,000 hours of operation. ** Dose Level: >2220mJ/cm
2
after 5,000 hours of operation.
*** ANSI class 150 flange.

Das könnte Ihnen auch gefallen